1 Electrical System Studies INTRODUCTION s experienced professionals provide electrical systems planning and design services to improve the safety and the reliability of electric power systems. The planning, design and operation of each power system requires comprehensive analyses, which assess current performance as well as examine the effectiveness of alternatives for system improvement and expansion. The Electrical System Studies Department offers systems modeling, short circuit analysis, power flow analysis, harmonic analysis, reliability analysis, dynamic and transient analysis, motor starting/acceleration studies, protective device coordination, and power factor correction. Our approach and experience provides value-added engineering services for your company beyond traditional power systems analysis and design. RECENT PROJECTS GENERAL MOTORS SHORT CIRCUIT AND PROTECTIVE DEVICE COORDINATION STUDY conducted a Short Circuit and Protective Device Coordination Study for General Motors Worldwide Facilities Group. The primary purpose for this study was to be able to coordinate plant system operations based upon the available electric supply arrangement and identify all electrical system deficiencies that require correction. A secondary purpose for this study is to update and standardize the available site documentation for protective device coordination and equipment fault duties. We have the practical experience and expertise to optimize performance of your power system has performed this study at the following four sites: Fairfax Assembly Center in Kansas City, Allison Transmission plant in Indianapolis, Arlington Assembly Center in Texas, and Mansfield Metal Fabrication Plant in Ohio. performed electrical system data gathering of the electrical system at the sites. A model was then developed from utility interconnect voltage to the 480V distribution to facilitate the execution of the short circuit and protective device coordination studies.
2 An Equipment Evaluation Report was prepared that indicates which equipment Failed or was Marginal with respect to being rated for the worst-case fault currents. For each substation room, a layout drawing was prepared that shows the general arrangement of equipment within the room with an equipment elevation drawing showing the layout of the transformers, breakers and protective devices. A one-line diagram of the electrical equipment connectivity was also prepared which shows all relevant electrical devices. Time-current curves (TCC s) were provided for each substation, showing the coordination of the protective devices. Equipment ratings and additional system information were provided for each substation room. CITY OF ANAHEIM, CALIFORNIA conducted a comparative analysis of the utility industry, comparing the engineering and operations policies and procedures among a broad cross-section of municipal utilities, investor-owned utilities, and electric cooperatives. Comprehensive surveys were prepared and issued to forty utilities. Twenty-three utilities agreed to participate and subsequently provided a response. The following engineering and operations topics were addressed in the survey: Construction and Material Standards Electric Power System Data: System Planning System Operation System Inventory Power Quality Assessment Organizational Structure System Communications System Maintenance Emergency Restoration Plan Work Order Process Capital Budgeting Our approach and experience provides value-added engineering services ORANGE COUNTY SANITATION DISTRICT was contracted by Carollo Engineers to provide assistance in a comprehensive system study for two wastewater treatment plants for Orange County. s scope included development of a database for maintaining equipment ratings and maintenance information. This database was designed to transfer equipment information into the ETAP load flow and short circuit analysis programs. Information shared between ETAP and this custom-designed database allowed reports to be generated that compared equipment ratings with system parameters. Burns & McDonnell s scope also included a reliability study using the Fault
3 Tree reliability analysis software, evaluation of the protective device coordination throughout both plants and a neutral grounding study. also was contracted to review Carollo s short circuit, load flow, motor starting, and harmonics studies. These studies included analysis of the existing electrical systems, recommendations for improvements, analysis of the improved scenarios, and recommendations for future planning through the year CORN BELT POWER COOPERATIVE developed a short-circuit study database in Aspen, performed a short circuit study and calculated relay settings for Corn Belt s 161-kV and 69-kV transmission systems. Following the initial study, was contracted to provide additional relay settings for several new substations. also prepared a Facilities Rating Document for Corn Belt to comply with NERC standards requirements. This document described the ratings for major transmission system components and the methodology used to determine equipment ratings. Corn Belt has continued to use to trouble-shoot relay coordination problems and to provide miscellaneous system studies as required. SOUTHERN ILLINOIS POWER COOPERATIVE (SIPC) provided a review of SIPC s 161-kV, 138-kV and 69-kV system relay settings as a total project for interface with the neighboring utilities, three distribution cooperatives and two municipals. The review included relays for the transmission lines, transmission substation buses, transmission substation transformers, and transmission substation capacitor banks. High side fusing of transformers at the distribution substations was reviewed for proper coordination with upstream relaying. Recommendations for improved coordination were provided with s final report. SIPC continues to use to provide further protective coordination of new facilities as appropriate.
4 CITY OF WAMEGO, KANSAS prepared a long-range plan of the City s electrical distribution system needs. A condition assessment of the existing distribution system was performed as part of the work. The final plan included development of practical and economical means of serving anticipated future load, recommendation of system improvements and preparation of construction cost estimates for the recommended work. LAWRENCE LIVERMORE NATIONAL LABORATORIES (LLNL) prepared an Electrical Utilities Master Plan for LLNL. This work included a condition assessment of the electrical system, a load forecast, power flow analysis of the existing system and review of the SCADA and metering systems. Expansion plans for the next five years and long-term plans for the next 20 years were evaluated. Recommended modifications and improvements were identified for LLNL s consideration. TEXAS-NEW MEXICO POWER COMPANY (TNMP) was retained by TNMP to perform a reliability study regarding the quality of service to the City of Sanderson, Texas. The 69-kV transmission line from Fort Stockton to Sanderson, the distribution substation in Sanderson, the 4-kV distribution system in Sanderson, were compared with industry standard values. Recommendations were proposed to improve the system reliability, and construction cost estimates for implementation of the recommendations were prepared. FLORIDA KEYS ELECTRIC COOPERATIVE (FKEC) prepared a long range planning study for FKEC to analyze the performance of the existing transmission and distribution systems, and to make recommendations for system modifications through a 20-year planning period. A system aging study was performed to aid FKEC in determining an economical replacement program for system components over the 20-year planning horizon. The 138-kV transmission system and the 24.9-kV distribution system were reviewed, load flow cases were prepared and system improvements were recommended. Construction cost estimates were prepared for the recommended alternatives.
5 DEPARTMENT OF DEFENSE JOINT PROGRAM OFFICE FOR INFRASTRUCTURE ASSURANCE was contracted to provide a site assessment of McConnell Air Force Base in Wichita, Kansas. evaluated the regional and local area electrical systems and the onbase distribution system. Power flow analysis of the regional transmission system was reviewed and an assessment of the reliability of the system was provided. A condition assessment of the on-base distribution system was performed. An assessment of the reliability of the local area and on-base distribution system was provided. Failure mode and effect analysis was used to document reliability recommendations. Cost estimates were provided for the various improvement alternatives. CITY OF ANAHEIM, CALIFORNIA was contracted to provide a comprehensive Electrical System Planning Study. The scope included establishment of planning criteria and reliability guidelines; a condition assessment of the City s 66-kV transmission system and 12-kV distribution system; a load growth forecast; a land use forecast; power flow and short circuit studies projected out 20 years in 5-year increments; reliability studies utilizing failure mode and effect analysis; a departmental organizational structure review; a communications network review; an operations and maintenance review; and a construction standards and material management review. The findings and recommendations were required to be presented to the City Council and the Anaheim Public Utilities Board. MUSCATINE POWER & WATER provided transmission-planning services to develop a ten-year plan for Muscatine Power & Water s electric power system. As part of this project, developed power system models, completed power flow analyses to identify transmission system limitations, developed and evaluated improvement and expansion alternatives and analyzed through-flow and import and export capability. SOUTHERN MARYLAND ELECTRIC COOPERATIVE was contracted by Southern Maryland Electric Cooperative to engineer, procure and construct electric facilities to utilize two existing diesel engine-generators owned by the Charlotte Hall Veterans Home for peak sharing. As part of this project, Burns & McDonnell completed engineering analyses to examine each application s compliance with minimum transfer times established by
6 the National Electric Code and National Fire Protection Association. Each application was examined to confirm that the design of electric facilities would provide transfer capability from normal to emergency power for essential electrical systems within ten seconds after loss of normal power with local generation initially paralleled with commercial power. MANFIELD DEVELOPMENT, MALAYSIA Retained as Banker s Engineer for the Kulim Hi-Tech Industrial Park, Malaysia. completed an independent technical assessment of the developer s design criteria, conceptual design, technical specifications and contract documents for the Kulim Hi- Tech Industrial Park, Malaysia. CITY OF GARDNER, KANSAS provided planning services to develop long range plans for the City of Gardner s electric distribution system. reviewed the utility s planning criteria, developed area load forecasts, developed comprehensive computer models of the existing system, analyzed the system s short and long range requirements, and developed a recommended improvement and expansion plan. An important part of this project was the completion of a fast-track study to identify the immediate system needs to accommodate the addition of a new high school. developed electric load profiles for the new high school based on computer modeling of the building s heating, air-conditioning, lighting and auxiliary loads, design and construction, and occupancy. Power flow analyses were completed in order to examine the effectiveness of system improvements. also developed computer maps, reviewed sectionalizing practices, and developed construction and material specifications for underground electric service extensions. LEE COUNTY ELECTRIC COOPERATIVE, NORTH FORT MYERS, FLORIDA completed an independent technical assessment of the utility s transmission and distribution systems and related engineering and operation procedures. The purpose of each assessment was to determine the present condition and operations of each system, make comparisons of engineering and operations policies to current industry standards and utilities of similar size in the areas of system planning, design, construction, operation, and
7 maintenance of transmission, distribution and substation facilities. Recommendations consistent with improving the overall reliability of the utility s electric power system were provided. KNOXVILLE UTILITIES BOARD, KNOXVILLE, TENNESSEE Knoxville Utilities Board retained to develop an electrical transmission and distribution master plan to provide a guide for orderly development of their electric power system. The development of the master plan involved areas of system planning. reviewed the utility s planning criteria, developed area load forecasts, developed comprehensive computer models for the existing power system, analyzed the system s short and long-range requirements, and developed a recommended plan for system improvement and expansion. Since the present and future design of this power system greatly affects this electric system s overall reliability. completed technical reviews of the existing system to provide reliability improvements. Additionally, the utility s existing design practices and standards related to sectionalizing, lightning protection and the application of voltage regulation equipment were reviewed. KOCH REFINING COMPANY, CORPUS CHRISTI, TEXAS performed comprehensive power system analyses to support development of a long-range electric utility plan for Koch Refining Company s East and West Refineries located in Corpus Christi, Texas. Power flow and short circuit analyses were completed to assess the performance of the existing electric power system and examine the effectiveness of alternatives for system expansion. Additional technical studies were completed to further examine specific improvements including harmonic analysis, reliability analysis and protective device coordination. Comprehensive reliability analyses based on probability techniques were completed for both refineries. Value-based system planning was used to justify reliability improvements. Opportunity costs were assigned to various levels of reliability based on the dollar value associated with an electrical outage. The investment cost required to eliminate the outage was compared to the cost of the lost opportunity to allow justification of the reliability-based improvement.
8 Koch Refining Company continues to use for updates to the system models and for miscellaneous system studies and protective device coordination reviews. TOP O MICHIGAN ELECTRIC COMPANY developed an electric system long-range plan which included development of planning criteria, documentation of our study methodology; development of area load forecasts; computer modeling of the existing transmission and distribution systems; technical evaluation of the existing transmission and distribution system; development of exploratory plans; and technical and economic evaluation of exploratory plans. Burns & McDonnell s compared exploratory plans to provide the recommended long-range plan. Top O Michigan s short, intermediate and long-range demand levels were estimated to be 80, 125 and 168 MW, respectively. This provides an indication of the relative size of the electric power system. CITY OF OTTAWA, KANSAS developed an electric system master plan which included development of planning criteria, documentation of our study methodology; development of area load forecasts; computer modeling of the existing distribution system; technical evaluation of the existing distribution system; development of exploratory plans; and technical and economic evaluation of exploratory plans. Burns & McDonnell s compared exploratory plans to provide the recommended long-range plan. Economic analyses of power supply options were also completed. The City s short, intermediate and long-range demand levels were estimated to be 32.9, 36.4 and 39.4 MW, respectively. This provides an indication of the relative size of the electric power system. NAVY BASE ELECTRIC UTILITY PRIVATIZATION STUDIES conducted a very large utility privatization study for the US Navy. The purpose of the study was to determine and document general utility system condition, system replacement cost, depreciated value, upgrade cost requirements, and equipment needs for the purpose of privatizing the government assets. Work included site inspections, employee interviews, map and document reviews, electrical equipment inventory, and a condition assessment. Reports included site condition assessment, equipment inventory, operating performance, maintenance program, system reliability, capacities, noted deficiencies and code violations, safety violations,
9 recommended improvements, and a list of documents/electrical maps reviewed. LIGHT RAIL TRAIN SPECIAL CONCERNS STUDY The Minnesota Department of Transportation proposed a Light Rail Train System that required the relocation, replacement and/or modification of major downtown 15-kV feeders owned by Northern States Power (now part of Xcel Energy). was retained to mediate technical and cost issues between the parties. Work performed included an analysis of potential vibration effects resulting from light rail train operation on the existing under street utility structures, a review with comments on the need for cathodic protection of the utility plant, review of applicable codes, past practice and any other items deemed pertinent to recommend safe working clearances, and development of an estimate of costs necessary to relocate and accommodate NSP s facilities in the downtown area.
Electric Operations Manager
CITY OF ANAHEIM invites applications for the position of: Electric Operations Manager SALARY: $10,602.75 - $14,578.75 Monthly $127,233.00 - $174,945.00 Annually OPENING DATE: 04/07/16 CLOSING DATE: Continuous
Generation Interconnection Feasibility Study Report-Web Version. PJM Generation Interconnection Request Queue Position Z1-055
Generation Interconnection Feasibility Study Report-Web Version For PJM Generation Interconnection Request Queue Position Z1-055 South Bend Generation Project March 2014 PJM Interconnection 2014. All rights
Hyperlinks are Inactive
Prepared by: NIB/EOB PLANNING GUIDE FOR SINGLE CUSTOMER SUBSTATIONS SERVED FROM TRANSMISSION LINES 05503 Department: Electric T&D Section: T&D Engineering and Technical Support Approved by: G.O. Duru (GOD)
Title 20 PUBLIC SERVICE COMMISSION. Subtitle 50 SERVICE SUPPLIED BY ELECTRIC COMPANIES. Chapter 02 Engineering
Title 20 PUBLIC SERVICE COMMISSION Subtitle 50 SERVICE SUPPLIED BY ELECTRIC COMPANIES Chapter 02 Engineering Authority: Public Utility Companies Article, 2-121, 5-101 and 5-303, Annotated Code of Maryland.
TRANSMISSION Field Services (January 30, 2014)
TRANSMISSION Field Services (January 30, 2014) Vice President Transmission Field Services The Vice President - Transmission Region Operations is responsible for the safe, reliable, cost-effective, and
ENGINEERING COMPETENCIES ENTRY LEVEL ENGINEER. Occupation Specific Technical Requirements
ENGINEERING COMPETENCIES ENTRY LEVEL ENGINEER Responsible for performing entry level engineering analysis, design, plan, review and inspection for small to medium projects and/or designated segments of
Green Power Connection Net Energy Metering Engineering Review Process in Delaware and Speeding Up the Application Fee Process
Green Power Connection Net Energy Metering Engineering Review Process in Delaware and Speeding Up the Application Fee Process Presented by: Marianne Mannschreck Date: Welcome A Look at the Net Energy Metering
COMPLIANCE REVIEW OF 2006/07 ASSET MANAGEMENT PLAN. Top Energy Limited
PB ASSOCIATES COMPLIANCE REVIEW OF 2006/07 ASSET MANAGEMENT PLAN Prepared for PB Associates Quality System: Document Identifier : 153162 Top Energy Final Report Revision : 2 Report Status : Final Date
Portland General Electric Company P.U.C. Oregon No. E-18 Original Sheet No. C-1 RULE C CONDITIONS GOVERNING CUSTOMER ATTACHMENT TO FACILITIES
P.U.C. Oregon No. E-18 Original Sheet No. C-1 RULE C CONDITIONS GOVERNING CUSTOMER ATTACHMENT TO FACILITIES 1. Acceptance of Electricity Service By establishing or requesting a POD or by continuing an
What Are the Qualifications to Conduct Arc Flash Studies? Where Do You Begin?
What Are the Qualifications to Conduct Arc Flash Studies? Where Do You Begin? Comparing apples-to-apples bids Plant Services Special Report A shock hazard analysis should be included as part of an arc
Fusible Disconnect Switch
Circuit Breakers Circuit breakers are used in panelboards and switchboards to provide circuit protection and provide a means of energizing and de-energizing a circuit. Siemens Sentron molded case circuit
POWER CORPORATION Requirements for Distribution Wires Access
POWER CORPORATION Requirements for Distribution Wires Access Contact Information: ENMAX Power Corporation 8820 52 St SE Phone: 514-3700 Calgary, Alberta Fax: 514-3719 T2C 4E7 Version 3.0 January 2005 i
Part 1 System Modeling & Studies for Existing Systems
Part 1 System Modeling & Studies for Existing Systems Operation Technology, Inc. Copyright 2009 Result of rapid release of energy due to an arcing fault between two conductors. Bus voltages > 208V Temperatures
Generation Interconnection System Impact Study Report. For. PJM Generation Interconnection Request Queue Position X1-114.
Generation Interconnection System Impact Study Report For PJM Generation Interconnection Request Queue Position X1-114 Sandyston January 2012 Preface The intent of the System Impact Study is to determine
SOUTHERN MARYLAND ELECTRIC COOPERATIVE, INC. HUGHESVILLE, MD
SOUTHERN MARYLAND ELECTRIC COOPERATIVE, INC. HUGHESVILLE, MD HOLLAND CLIFF HEWITT ROAD 230 KV TRANSMISSION LINE PROJECT ELECTRIC ALTERNATIVE EVALUATION STUDY BLACK & VEATCH CORPORATION B&V Project 146026(G)
Network Consulting for Power Grid Optimization
Network Consulting for Power Grid Optimization Project experience in India Network Consulting Competences Page 1 Our worldwide representation Manchester The Hague Denver Schenectady San Diego Houston Mexico
Electric Field Operations Organization
NSTAR Electric Transmission Function Job Summaries Electric Field Operations Organization Vice President, Electric Field Operations (Transmission) This position has primary responsibility for the planning,
Last revised: September 1, 2014 TRANSMISSION FUNCTION TITLES AND JOB DESCRIPTIONS
Last revised: September 1, 2014 TRANSMISSION FUNCTION TITLES AND JOB DESCRIPTIONS EVP, Chief Operations Officer, has primary responsibility for the overall planning, operations and control of the transmission
How the National Grid System Operates. Chris Gorman Lead Account Executive Syracuse
How the National Grid System Operates Chris Gorman Lead Account Executive Syracuse 2 Parts of the Electric System Parts of the Electric System 1. Generating Station: Produces Electricity. 2. Transmission
Electrical Engineering
Electrical Engineering Trust our people. R eady is a professional engineering firm with highlyqualified electrical and controls personnel focused on providing solutions to meet your specific needs. Ready
Minimizing Impact of Electric Utility Outages with Backup Generation
Minimizing Impact of Electric Utility Outages with Backup Generation Introduction of the Speaker Michael Dempsey, PE Senior Electrical Engineer Carter & Burgess, Inc. Energy & Power Solutions Facility
COLORADO SPRINGS UTILITIES ATTACHMENT K TO OPEN ACCESS TRANSMISSION TARIFF
COLORADO SPRINGS UTILITIES ATTACHMENT K TO OPEN ACCESS TRANSMISSION TARIFF I. INTRODUCTION The City of Colorado Springs, Colorado ( City ) is a Colorado home-rule municipal corporation with a population
Integration Capacity Analysis Workshop 11/10/15 California IOU s Approach
Integration Capacity Analysis Workshop 11/10/15 California IOU s Approach READ AND DELETE For best results with this template, use PowerPoint 2003 10 November 2015 Background and Importance of ICA Definition:
Effective: September 10, 2006 Vermont Attachment 1 to Rule 5.500 Public Service Board Page 1 of 6
Public Service Board Page 1 of 6 STANDARD APPLICATION FOR INTERCONNECTION OF GENERATION RESOURCES IN PARALLEL TO THE ELECTRIC SYSTEM OF: (Interconnecting Utility) Preamble and Instructions: An owner of
Rule 5.500 Fast Track Analysis for National Life Insurance Co.
Rule 5.500 Fast Track Analysis for National Life Insurance Co. For a 500 kw Solar array to be located at 155 Northfield Street in Montpelier, Vermont Green Mountain Power Pam Allen Date: 5/31/13 SECTION
ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F
ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F TABLE OF CONTENTS Appendix F - Electrical Engineering Design Criteria F.1 Introduction...F-1 F.2 Codes and Standards...F-1 F.3 Switchyard and Transformers...F-1
Power System review W I L L I A M V. T O R R E A P R I L 1 0, 2 0 1 3
Power System review W I L L I A M V. T O R R E A P R I L 1 0, 2 0 1 3 Basics of Power systems Network topology Transmission and Distribution Load and Resource Balance Economic Dispatch Steady State System
TERMS AND CONDITIONS
Virginia Electric and Power Company TERMS AND CONDITIONS XXIV. GENERATOR INTERCONNECTION STANDARD Electric generator interconnection service includes only the ability to interconnect an electric generator
FIXED CHARGE: This is a cost that goes towards making the service available, including
ELECTRICITY BILL COMPONENTS FIXED CHARGE: This is a cost that goes towards making the service available, including installation and maintenance of poles, power lines and equipment, and 24-hour customer
Electric Power Distribution
Electric Power Distribution A S Pabla Consulting Engineer and Former Chief Engineer Punjab State Electricity Board McGraw-Hill New York Chicago San Francisco Lisbon London Madrid Mexico City Milan New
Energy Systems Integration
Energy Systems Integration Dr. Martha Symko-Davies Director of Partnerships, ESI March 2015 NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy,
Morris S. Stover, P.E. Sponsor, Transmission Area
Page 1 of 5 Job Function Morris has nearly 28 years in the power industry including design and construction of transmission line and substation facilities, He has extensive experience in contract development
SCADA Controlled Multi-Step Automatic Controlled Capacitor Banks & Filter Banks
SCADA Controlled Multi-Step Automatic Controlled Capacitor Banks & Filter Banks Introduction SCADA (Supervisory Controlled and Data Acquisition) controlled multi-step metalenclosed automatic capacitor
Generator Interconnection and Deliverability Study Methodology Technical Paper
Generator Interconnection and Deliverability Study Methodology Technical Paper July 2, 2013 Generator Interconnection and Deliverability Study Methodology Table of Contents Introduction... 1 Section One:
Litigation Services & Information
Litigation Services & Information Laurence "Lo" Lehman, P.E. Lehman Engineering Company Lehman Engineering has been providing engineering, design, and consulting services for electrical power systems to
FRCC Standards Handbook. FRCC Automatic Underfrequency Load Shedding Program. Revision Date: July 2003
F R C C FRCC Standards Handbook FRCC Automatic Underfrequency Load Shedding Program Revision Date: July 2003 FRCC Underfrequency Load Shedding Program Modification and Approval Process Requests to modify
Job Descriptions. Job Title Reports To Job Description TRANSMISSION SERVICES Manager, Transmission Services. VP Compliance & Standards
Updated July 11, 2013 Job Descriptions Job Title Reports To Job Description TRANSMISSION SERVICES VP Compliance & Standards Develops strategy and business plans for efficient, safe, reliable, regulatorycompliant
Pennsylvania Summer Reliability
A. Reliability Enhancement Programs In 2015, Pennsylvania Power Company s ( Penn Power or Company ) reliability plan incorporates projects and programs to enhance overall reliability. The plan is structured
UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation
Basis of Design This section applies to the design relating to low voltage switchboards. Design Criteria UW Class N1 facilities main switchboards shall be rear accessible. The main, tie and feeder breakers
F.C. Chan General Manager, CLP Engineering Ltd., Hong Kong SAR, China
ELECTRIC POWER DISTRIBUTION SYSTEMS F.C. Chan General Manager, CLP Engineering Ltd., Hong Kong SAR, China Keywords: Distribution system planning, Load characteristics, Subtransmission Lines, Distribution
PROGRAM CRITERIA FOR ELECTRICAL ENGINEERING TECHNOLOGY
PROGRAM CRITERIA FOR ELECTRICAL ENGINEERING TECHNOLOGY Scope These program criteria apply to programs having titles involving Electrical Engineering Technology including: electrical engineering, electrical
MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS
MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS Meher Capacitors offers reliable and innovative products and solutions in the fields of Reactive Power Compensation, Power Quality and Energy
PacifiCorp Original Sheet No. 476 FERC Electric Tariff, Substitute 6 th Rev Volume No. 11 APPENDIX 2 TO SGIP
PacifiCorp Original Sheet No. 476 APPENDIX 2 TO SGIP SMALL GENERATOR INTERCONNECTION REQUEST (Application Form) Transmission Provider: Designated Contact Person: Address: Telephone Number: An Interconnection
Preparing for Distributed Energy Resources
Preparing for Distributed Energy Resources Executive summary Many utilities are turning to Smart Grid solutions such as distributed energy resources (DERs) small-scale renewable energy sources and energy
White Paper. Convergence of Information and Operation Technologies (IT & OT) to Build a Successful Smart Grid
White Paper Convergence of Information and Operation Technologies (IT & OT) to Build a Successful Smart Grid Contents Executive Summary... 3 Integration of IT and OT... 4 Smarter Grid using Integrated
Ontario s s Water and Wastewater Energy Management Best Practices
Ontario s s Water and Wastewater Energy Management Best Practices Erin Cain February 27 th, 2007 AWWA/WEF Joint Management Conference February 25-28, 2007 Introduction What can I take back and apply? Energy
Midwest Reliability Organization Procedure For NERC PRC-012
Midwest Reliability Organization Procedure For NERC PRC-012 A. Introduction The following procedure developed by the MRO Protective Relay Subcommittee (PRS) and Transmission Assessment Subcommittee (TAS)
SPECIFICATION COG-2007
Cleco Power LLC SPECIFICATION COG-2007 FOR PARALLEL OPPERATION OF CUSTOMER-OWNED GENERATION ON CLECO S ELECTRICAL SYSTEM Revised: March 7, 2014 CONTENTS ITEM NO. TITLE PAGE NO. 1.0 Scope 3 2.0 Policy On
N.J.A.C. 14:8-4 NET METERING FOR CLASS I RENEWABLE ENERGY SYSTEMS
N.J.A.C. 14:8-4 NET METERING FOR CLASS I RENEWABLE ENERGY SYSTEMS 14:8-4.1 Scope This subchapter sets forth net metering requirements that apply to electric power suppliers, basic generation service providers
C.I.8.2 Offsite Power System. C.I.8.2.1 Description
C.I.8 Electric Power The electric power system is the source of power for station auxiliaries during normal operation, and for the reactor protection system and ESF during abnormal and accident conditions.
05-15-98 ELECTRICAL ENGINEERING ASSOCIATE, 7525
CITY OF LOS ANGELES CIVIL SERVICE COMMISSION CLASS SPECIFICATION POSTED JUNE 1999 05-15-98 ELECTRICAL ENGINEERING ASSOCIATE, 7525 Summary of Duties: Performs professional electrical engineering work in
SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.
PART 1 - GENERAL SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less. RELATED SECTIONS Division 16 Section "Basic Electrical Materials and Methods" for general
EPCOR Distribution & Transmission Inc.
Decision 3478-D01-2015 Victoria E511S Substation Expansion February 17, 2015 Alberta Utilities Commission Decision 3478-D01-2015 Victoria E511S Substation Expansion Proceeding 3478 Application 1610934-1
Agenda do Mini-Curso. Sérgio Yoshio Fujii. Ethan Boardman. [email protected]. [email protected]
Agenda do Mini-Curso Sérgio Yoshio Fujii [email protected] Ethan Boardman [email protected] Agenda do Mini-Curso Sistemas de Distribuição (DMS) Characteristics of Distribution Network
Emera Maine Proposed Potential Transmission Projects. Line Identification Line 75 - KR Sub. Estimated Cost $201,464 $0 $3,200,000
L75 & BW3 Rebuild ROW Phase I Keene Rd. Expansion for Oakfield Wind KR Transformer Addition Line Identification Line 75 - KR Sub Location Bangor Chester Chester Estimated Cost $201,464 $0 $3,200,000 Voltage
Submit shop drawings for equipment provided under this section Shop drawings shall indicate:
Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,
Implementing Low-Cost Distribution Automation Programs
Implementing Low-Cost Distribution Automation Programs By: Jai Belagur, P.E. Contact: Jai Belagur Power System Engineering, Inc. 1532 West Broadway, Suite 100, Madison, WI 53713 Phone: 608-268-3544 E-mail:
Distribution Operations with High-penetration of Beyond the Meter Intermittent Renewables. Bob Yinger Southern California Edison April 15, 2014
1 Distribution Operations with High-penetration of Beyond the Meter Intermittent Renewables Bob Yinger Southern California Edison April 15, 2014 Southern California Edison SCE provides power to: Nearly
Unified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to
City of Gardner Electric, Water and Wastewater Utilities. Request for Information (RFI) 1. Purpose of Request
City of Gardner Electric, Water and Wastewater Utilities Request for Information (RFI) 1. Purpose of Request The City of Gardner ( City ), faces challenges related to maintaining its basic infrastructure,
MICROGRIDS FOR DATA CENTERS
MICROGRIDS FOR DATA CENTERS Table of Contents Summary of Pareto Energy s Microgrid Business Model Understanding the Risks of On-Site Power for Critical Infrastructure The Pareto Energy GridLink Solution
Microgrid Building block for Smart Cities
Microgrid Building block for Smart Cities Shay Bahramirad, Ph.D. Manager of Smart Grid & Technology December 2014 COMED OVERVIEW 1 The service territory covers 11,400 mi 2 in Northern Illinois Serving
Dan T. Stathos, CPA* Associate Director
Dan T. Stathos, CPA* [email protected] Austin, Texas Direct: 512.493.5415 Professional Summary Dan Stathos, an in NCI s Austin, Texas office, has been involved with electric, gas, water and telephone
ATTACHMENT F. Electric Utility Contact Information Utility Name. For Office Use Only
ATTACHMENT F CATEGORY 2 GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 20 KW BUT LESS THAN OR EQUAL TO 150 KW Also Serves as Application for Category
PA PUC AERS & Metropolitan Edison Company Site Visit
PA PUC AERS & Metropolitan Edison Company Site Visit October 26, 2010 Scott Lowry Director-Operation Services, Met-Ed Andrew Zulkosky Manager-Engineering, Met-Ed Curt Christenson Manager-York Customer
Federal Wage System Job Grading Standards for Electric Power Controlling, 5407. Table of Contents
Federal Wage System Job Grading Standards for Electric Power Controlling, 5407 Table of Contents WORK COVERED... 2 WORK NOT COVERED...2 TITLES... 2 GRADE LEVELS... 2 SPECIAL ADDITIONAL RESPONSIBILITIES...
PMCS. Integrated Energy Management Solution. Unlock the Full Potential of Power Networks Through Integration. Complete Solution. Informed Decisions
PMCS Integrated Energy Management Solution Unlock the Full Potential of Power Networks Through Integration Power Management Control System (PMCS) is a highly customizable, fully integrated end-to-end Energy
ATTACHMENT G. Network Operating Agreement
ATTACHMENT G Network Operating Agreement 1. PURPOSE OF NETWORK OPERATING AGREEMENT The purpose of this Agreement is to identify contractual requirements related to Network Integration Transmission Service
Addendum #2 Contract UK-11-13
Addendum #2 Contract UK-11-13 Utilities Kingston Purchase and Replacement of Switchgear at Kingston Hydro Substation MS11 March 25, 2011 Delivered to: All RFP recipients Total number of pages: Nine (9)
Transmission Function Employees Job Titles and Descriptions 18 C.F.R 358.7(f)(1)
Date of Last Change to the Provided Information August 27 th, 2015 Director, Transmission Operations The employee in this position is responsible for effectively managing the operation of FirstEnergy Utilities
Public School Teacher Experience Distribution. Public School Teacher Experience Distribution
Public School Teacher Experience Distribution Lower Quartile Median Upper Quartile Mode Alabama Percent of Teachers FY Public School Teacher Experience Distribution Lower Quartile Median Upper Quartile
BC Hydro. Electric Distribution System Cost of Service Study
BC Hydro Electric Distribution System Reimer Consulting Group Inc. Arnie Reimer May 7, 2010 Table of Contents 1. Executive Summary... 3 2. BC Hydro Electric Distribution System... 4 2.1. General Description...
Switchgear and Metal-Enclosed Bus
Section 18 Switchgear and Metal-Enclosed Bus 180. SWITCHGEAR ASSEMBLIES 180A. General Requirements for All Switchgear. This rule covers general requirements for all switchgear. Examples of switchgear found
Commonwealth of Puerto Rico PUERTO RICO ELECTRIC POWER AUTHORITY. ANNUAL BUDGET OF CAPITAL EXPENDITURES FISCAL YEAR 2003-2004 (Dollars in thousands)
No. Title Amount Production Plant Thermal Production Plant 100 New Generation 15,865 160 Improvements to Steam Boilers 13,289 165 Improvements to Steam Turbine Generator 11,093 170 Improvements to Steam
Impact of electric vehicles on the IEEE 34 node distribution infrastructure
International Journal of Smart Grid and Clean Energy Impact of electric vehicles on the IEEE 34 node distribution infrastructure Zeming Jiang *, Laith Shalalfeh, Mohammed J. Beshir a Department of Electrical
Press Presse Press Presse
Press Presse Press Presse Energy Sector Renewable Energy Division Fact sheet Siemens Wind Power USA Erlangen, December 3, 2010 Siemens Wind Power USA Overview The U.S. is one of the most important wind
Current Limiting Protector For Systems rated 2.8-38kV and continuous currents through 5000A.
Current Limiting Protector For Systems rated 2.8-38kV and continuous currents through 5000A. Arc Flash and Arc Blast reduction Network protection SCADA adaptable Indoor/outdoor application Professional
Investor day. November 17, 2010. Energy business Michel Crochon Executive Vice President
Investor day November 17, 2010 Energy business Michel Crochon Executive Vice President We built a global leadership in medium voltage and grid automation with Areva Distribution MV switchgears & systems
Future of Electric Distribution Dialogue
Future of Electric Distribution Dialogue Webinar Series Session I: State of U.S. Electric Distribution July 11, 2012 2:00 3:30 p.m. EDT Session I: State of U.S. Electric Distribution 2:00 p.m. Opening
2010 Allocations to States of Volume Cap for Qualified School Construction Bonds
2010 Allocations to States of Volume Cap for Qualified School Construction Bonds Total Dollar Allocation by State/ State/Territory Territory Alabama 140,453,000 Alaska 28,163,000 Arizona 171,115,000 Arkansas
Audit Report Rottnest Island 2015 Network Quality and Reliability of Supply Performance Audit - Operation of Compliance Monitoring Systems
ABN 20 009 454 111 Rottnest Island 2015 Network Quality and Reliability of Supply Performance Audit - Operation of Compliance Monitoring Systems Telephone: +61 8 9260 0003 Fax: +61 8 9225 7447 E-Mail:
D.3 South Minneapolis Electric Distribution Delivery System Long-Term Study
D.3 South Minneapolis Electric Distribution Delivery System Long-Term Study Xcel Energy April 2009 Hiawatha Project SOUTH MINNEAPOLIS ELECTRIC DISTRIBUTION DELIVERY SYSTEM LONG-TERM STUDY Scott Zima Distribution
Design of electrical power system for a 1000MW nuclear power generating station
Design of electrical power system for a 1000MW nuclear power generating station K Raja, K Yesunadam Dept. of Electrical & Electronics Engineering, Lingaya s Institute of Management & Technology, Vijayawada,
Governor s Two-Storm Panel: Distribution Infrastructure Hardening Options and Recommendations
Governor s Two-Storm Panel: Distribution Infrastructure Hardening Options and Recommendations Dana Louth, CL&P VP - Infrastructure Hardening December 14, 2011 0 Topics for today s presentation Review of
Compendium to the National Technology Benchmarks - NTB 2010 TECHNICIAN
Compendium to the National Technology Benchmarks - NTB 2010 TECHNICIAN Reg d trademark of Canadian Council of Technicians and Technologists GENERAL PROGRAM CRITERIA FOR ALL DISCIPLINES Technician Level