T7560A,B,C Digital Wall Module

Similar documents
TR21, TR22, TR23, and TR24 Wall Modules

Electronic Control Devices The European Product Catalogue 2007

Radiant Temperature Sensor TY7321

Electronic Control Devices The European Product Catalogue 2007

Duct Humidity Transmitter

T7079A,B Solid State Remote Temperature Controllers

Advantium 2 Plus Alarm

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

HMI display Installation Guide

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Table of Contents. 1 - Specifications Installation Wiring User controls...7

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

Contents. Document information

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

T775U Series 2000 Electronic Stand-Alone Controller

Drayton Digistat +2RF/+3RF

Y7230A CO 2 Alarm System

INSTALLATION INSTRUCTIONS

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

LOXONE 12 Channel Amplifier

MINI MCR-SL-R-UI(-SP)

WD-AMX Water Detection Controllers

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

MechoNet TM Network Interface (MNI) Specification Submittal

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

FX07 Field Controller

TruPower-Portable-500W. Solar Starter kit

EDI Distributor Control Interface Wiring and Setup Instructions

User Manual THR840DUK Digital Thermostat

Installation Instructions. Wireless Adapter/Repeater. Introduction Rev C

EXTERNAL DIMENSIONS AND PARTS

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

User Guide. Model Insulation Tester / Megohmmeter

T 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ

CQM1-SF200/CS1W-SF200

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

Multi Media Cable Tester TM-901N/TM-902/TM-903

GSM HOME SECURITY SYSTEM

Series LC6D/LC6C. To power supply PLC. LC6C dedicated teaching box P.971. Options P.973

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module (MS/TP)

! WARNING. Before using product, read and understand instructions.

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

HM-W536 Install Guide

HERZ-Thermal Actuators

Schneider Automation Modbus Plus Network Installing Clustered Node Devices Version 2.0

SLIM LINE FUME HOOD MONITOR

DLP-PU/E Instruction Manual

CompactLogix Power Supplies Specifications

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Manual for Fire Suppression & Methane Detection System

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

HP UPS R1500 Generation 3

LIEBERT VNSA Installation Sheet

MCR1900 Media Converter 19-Slot Chassis

ADM1TE 5/30A DIN rail single phase two wire energy meter

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

CAUTION OPC-LM1-ID. Option Card for Frequency Divider. Fuji Electric FA Components & Systems Co., Ltd. Instruction Manual

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

SECTION LOW VOLTAGE LIGHTING CONTROLS

No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1

Applied Electronics. Commercial Dimming System UPDATE NOTICE

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Install Guide CT101. Caution. Caution

Inwall Room Temperature Unit

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

SmartVFD Frame 4 Wiring Diagrams and Dimensional Drawings

Installation Instructions for FT-10 Network PowerCommand ATS Communication Module (NCM) Kits and

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

SMART SENSOR COLLECTION

Installation Instructions

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

SELECTION GUIDE INPUT CHARACTERISTICS. Voltage set point accuracy. Overall voltage error. Temperature coefficient of output voltage (slope)

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

TS93 EMR T/PT/TDE. Surface applied door closer

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Digital inductive conductivity transmitter

User Manual Weather station V 0.2

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1

Install Guide 3M-50. Caution. Caution

evohome Wireless Radiator Zoning Kit Installation & User Guide

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

Digital input modules

Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work.

AUTODIALLER / QUICKDIALLER - SA132

Physical Specifications (Custom design available.)

UCC 1 USB-CAN CONVERTER

Transcription:

T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital Wall Module (DWM) wiring can be sized from 16 to 22 AWG (1.5 to 0.34 mm 2 ), depending on the application. The max. length of wire from a device to a DWM is 164 ft (50 m). Twisted pair wire is recommended for wire runs longer than 100 ft (30.5 m). CAUTION EMI Noise Introduction. Risk of erratic system operation. Keep wiring at least one ft (305 mm) away from large inductive loads such as motors, line starters, lighting ballasts and large power distribution panels. During installations, try to avoid areas of high EMI noise. Run DWM wiring separately from 50 Vac or greater power wiring. WARNING / CAUTION Risk of electric shock or equipment damage! Do not touch any live parts inside the DWM housing. Disconnect the power supply before making connections to or removing connections from the DWM's terminals. Do not reconnect the power supply until you have completed the installation. If the DWM is powered via terminal 8 and connected to earth ground, then the cable must be shielded. INSTALLATION INSTRUCTIONS Table 1. Types of DWM sensor 1 setpoint bypass fan override T7560A Tmp wheel button button T7560B Tmp/Hum wheel button button T7560C Tmp/Hum - - - 1 Tmp = Temperature sensor; Hum = Humidity sensor Table 2. Controller SW requirements for powering via terminal 5 and new LCD signaling VAV W7751H Fan Coil Unit W7752 W7754 Hydronic W7762 Chilled Ceiling W7763 1.02.15 1.00.04 1.00.02 1.00.03 1.00.03 NOTE: A software module (ModAL module GNRSC02A) is available to adapt the DWM to the respective Excel 20, 50, 100, 500, 600, or 800 controller, making any further configuring obsolete. Contact your local Honeywell distributor for further details. DWM DISASSEMBLY The T7560A,B,C comes packed with a sub-base that mounts separately for ease of installation. The cover is fixed by a latch on the underside of the unit. Remove the cover as shown in Fig. 1 (T7560A,B) or Fig. 2 (T7560C): 1. Insert the tip of an awl or a similar narrow, pointed object into the small hole in the latch (T7560A,B) or simply depress the latch by hand (T7560C). 2. Pry off the cover. Observe precautions for handling electrostatic sensitive devices. Fig. 1. DWM disassembly (T7560A,B) U.S. Registered Trademark Copyright 2014 Honeywell Inc. All Rights Reserved

3. Verify DWM is wired according to Fig. 4. NOTE: For specific wiring requirements, see section Power below. Terminals Fig. 2. DWM disassembly (T7560C) INSTALLATION Mount the DWM on an inside wall approximately 54 in. (1.3 m) from the floor (or as specified on the installation drawings) to allow exposure to the average zone temperature. Do not mount the DWM on an outside wall, on a wall containing water pipes or near air ducts. Avoid locations that are exposed to discharge air from registers or radiation from lights, appliances, or the sun. The DWM is furnished with a terminal block; all field wiring connections are made to these eight terminals. The DWM must be mounted in vertical position with the LCD display to the top. Mount the subbase directly on a wall (see Fig. 3) using the type of screws appropriate for the wall material. 2 1 1 = Common 2 = Temperature sensor 3 = Setpoint (T7560C: Do not connect!) 4 = Bypass/fan* (T7560C: Do not connect!) 5 = LED input (T7560C: Do not connect!) 6 = Bypass** (T7560C: Do not connect!) 7 = Humidity output 8 = 24 Vac/dc input * With Excel 10 Controllers: W7750 (CVAHU), W7752 (FCU), and XL12 ** With Excel 10 Controllers: W7751H (VAV), W7762 (HYD), and W7763 (CHC) For W7753 (UV) and W7761 (RIO), see NOTE below. Fig. 4. Wiring of DWM NOTE: If connected to the W7753 (UV) Controller, both terminals 4 and 6 must be connected. NOTE: The W7761 Remote I/O Controller supports only terminals 2 (temperature), 7 (humidity), and 1 (common), as well as terminal 8 as voltage supply. NOTE: Wiring with terminal 8 is not necessary if: a) an FCU or CHC controller with software is connected (see Table 2); or b) an Excel 500 with 6V/8V/10V signaling from the controller is used. The T7560A must then be powered by terminal 5. Fig. 3. Mounting of DWM (T7560A,B shown) See Fig. 6 for T7560A,B,C mounting dimensions. WIRING Wire the terminal blocks as follows: 1. Strip 3/16 in. (5 mm) of insulation from the conductor. 2. Insert the wire in the required terminal location and tighten the screw to complete the termination. IMPORTANT Deviation from this rule can result in improper electrical contact. See Fig. 4. Power The DWM can be powered as follows: T7560A Preferably via the 5 V LED input (terminal 5); via terminal 8 is also possible. T7560B,C Via the 24 Vac/dc input (terminal 8). 2

IMPORTANT In the case of those controllers listed in Table 2, the DWM can be powered only via terminal 5, and only if a SW version listed in Table 2 or higher is installed. If the DWM is powered via terminal 5, the Excel 10 controller must be configured for LCD_DISPLAY (LED output continuously ON). NOTE: The 24 Vac power supply is needed only with the T7560B,C DWM (for the humidity sensor). Alternatively, a DC voltage source with 5...15 V can be connected to terminal 5 (see IMPORTANT note above). Alternatively, a DC voltage source with 18...27 V (e.g., 22 Vdc from W7750 CVAHU) can be connected to terminal 8. 2 1 Input Ratings Terminal 5 min. 5 Vdc, I max 3 ma, max. 15 Vdc, I max 4 ma, or the LED output of any Excel 10 controller Fig. 5. Mounting cover of T7560A,B DWM Terminal 8 24 Vac from controller, I MAX 6 ma, with a valid range of 18 V (I MAX 2.4 ma) to 27 V (I MAX 10 ma). Controllers with the following output ratings can be connected to terminal 5 (ratings are met by all Excel 10 controllers): 5 V with 389 Ω 4.3 V with 100 Ω 14.3 V with 1.5kΩ Use up to 16 AWG (1.5 mm 2 ) with a minimum of 18 AWG (1.0 mm 2 ) wire for connecting 24 Vac power to terminal 8. CAUTION Low Voltage Equipment. Risk of equipment damage. The 24 Vac power source for the DWM must be a Class II Power Source. To conform to Class II restrictions, transformers must not be larger than 100 VA. A transformer that is CE certified and meets the Low Voltage Device (LVD) requirements must be used in Europe for all installations of this product. The DWM power usage is 0.2 VA at 24 Vac. The DWM does not require a dedicated transformer. The DWM can get power from any convenient location in the 24 Vac power circuit. The 24 Vac power can come from the 24 Vac power terminals on the nearest controller or directly from a 24 Vac transformer, whichever is closer. When all wiring is complete, attach the cover of the DWM as is shown in Fig. 5. NOTE: Make sure that the latch on the underside of the DWM engages properly and in the case of the T7560A,B that the three control buttons protrude through the holes completely. Fig. 6. DWM dimensions in inches (mm) 3

CONFIGURATION (T7560A,B) After installation, the T7560A,B DWM must be configured in order to perform as desired. This is done by using the buttons and the setpoint wheel (see Fig. 7). NOTE: After approx. 10 seconds without further action, the DWM automatically falls back to normal mode. P1 Setpoint type setting / scale type setting Fahrenheit relative Fahrenheit absolute * Celsius relative Celsius absolute P2 Room temperature setting Do not display room temperature (setpoint, only) * Display room temperature Display room temperature and humidity, alternating every 5 seconds (T7560B, only) Fig. 7. Control elements of T7560A,B DWM NORMAL OPERATING MODE After the DWM is powered up by the controller, it will display the room temperature and will operate as configured by default. In the following, the respective default setting is marked with an asterisk (*). After power-up, all display segments are switched on for approx. one second (see Fig. 8). AUTO MANU PROG Fig. 8. Display of all segments after power-up ENTERING CONFIGURATION MODE 1. Press FAN OVERRIDE for at least 5 seconds. 2. Press UNIT ENABLE, then release FAN OVERRIDE, hold UNIT ENABLE for at least 5 seconds. 3. Release UNIT ENABLE. RESULT: The display shows and the DWM is ready for configuration (see below). 4. Press and hold FAN OVERRIDE while turning the setpoint wheel to select the parameter number. RESULT: The parameters with their currently set values are displayed; the behind the value indicates the currently set value (see below for values). 5. Release FAN OVERRIDE and turn the setpoint wheel to select the parameter value. 6. Confirm selection by pressing UNIT ENABLE. 7. Repeat steps 4 to 6 to configure next parameter, or press BYPASS to leave the configuration mode. P3 Bargraph use setting No Fan Auto, Off, On Auto, Off, 2 Speeds * Auto, Off, 3 Speeds P4 Controller type setting * New LCD signaling from controller (only for controllers and SW versions as listed in Table 2 or higher, in which case this setting must be selected; set Excel 10 controller to LCD_DISPLAY) LED override mode from controller, US signaling (100 ms pulses); with controllers W7750, W7751, W7753, W7761, and XL12 LED override mode from controller, European signaling (500 ms pulses); with controllers W7752, W7762, W7763, and XL12 (in the case of SW versions listed in Table 2 or higher, select ). LED occupancy mode from controller, European signaling (500 ms pulses); with controllers W7752, W7762, W7763, and XL12 Same as Excel 500 signaling from controller (10 V, 8 V, 6 V) P5 Pin 4 (Bypass/Fan) grounding Pin 4 not shorted to GND if override is pressed (UV-controller, W7753) * Pin 4 shorted to GND if override is pressed P6 Device type This item configures different devices. IMPORTANT: Keep the setting P6:1 and do not change to other configurations. 4

P7 Temperature offset * Temperature offset; values of 0 through 99 are valid. 50 = no change (default), 49 = -0.1 C, 51 = +0.1 C, etc. This offset varies the LCD display value, only. In order for this offset to have the proper effect, it must be set in the controller, too. P8 Remote reset of temperature setpoint overrides and fan speed overrides * disable remote reset of temperature setpoint override and disable remote reset of fan speed override. enable remote reset of temperature setpoint override and disable remote reset of fan speed override (takes effect ONLY if or has been selected AND or has been selected) disable remote reset of temperature setpoint override and enable remote reset of fan speed override (takes effect ONLY if or has been selected) enable remote reset of temperature setpoint override and enable remote reset of fan speed override (takes effect ONLY if or has been selected AND or has been selected) IMPORTANT In addition to P8, parameters P1 and P4 must also be set accordingly for the wall module see above! Explanation: The goal of this action is to reset those overrides which a room user has enacted at the wall module. Thus, in, e.g., hotels and office buildings, a typical requirement is to remotely reset the wall module setpoint override to zero, and to remotely reset the wall module fan speed override to Auto. NOTE: If the wall module has been set to OFF by the room user, it cannot be reset to auto. In the case of Excel 50 controllers, this reset can be done by sending 6 Volt (= unoccupied ) to the LED input of the wall module: As long as 6V is being sent to the LED input the wall module will be in unoccupied the local setpoint and/or fan speed setting will be reset and disabled. As long as 10V is being sent to the LED input the wall module will be in occupied the local setpoint and/or fan speed setting will be enabled. In the case of Excel 10 controllers, this reset can be done by switching from occupied to unoccupied. This will send a specially coded Excel 10 signal to the LED input of the wall module. "Unoccupied" means: Effective Unoccupied (moon on continuously), or Override Unoccupied (moon flashing). "Occupied" means: Effective Occupied (sun on continuously), or Override Occupied (sun flashing). P9 Limit setpoint - Limit setpoint to ±0 5 C (if set to Celsius) or to ±0 9 F (if set to Fahrenheit). Default (if set to Celsius): Default (if set to Fahrenheit): Example (units set to Celsius): A setting of means that the setpoint offset is limited to -3 to +3 C. Example (units set to Fahrenheit): A setting of means that the setpoint offset is limited to -8 to +8 F. PA Limit for humidity low limit output value - Limit the output value to 10 20% relative humidity in steps of 5%. This affects the output voltage at pin 7, only, and has no effect upon values appearing in the display. = 10%, = 15%, = 20% (default), = not used. RESETTING TO FACTORY DEFAULTS Pressing the left, middle, and right button simultaneously while powering the wall module will reset the wall module settings to the factory defaults values. When the reset has been completed, the display will show. HOW TO CHECK THE SOFTWARE VERSION Press the left and right button for approx. 5 seconds: After a LCD display test, you will see the current SW version of the device. 5

ACCESSORIES T7460LONJACK The T7460-LONJACK is a small board and allows easy access to LONWORKS or BACnet via the correspondingly wired wall module (apply appropriate wiring guidelines for LONWORKS or BACnet networks, as the case may be). The T7460-LONJACK provides an additional 3.5 mm jack socket for a 3.5 mm jack plug. Order quantity: set with 5 pieces Mounting Remove the setpoint wheel and put in the LonJack as shown in the following: LonWorks connection terminals PC connection (3.5 mm jack plug) Fig 9. T7460LONJACK Fig 10. Mounting T7460-LONJACK T7560 BLINDS Same material and color as housing; for covering nonoperational buttons. Order quantity: set of 50 pieces. Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Rolle, Z.A. La Pièce 16, Switzerland by its Authorized Representative: Automation and Control Solutions Honeywell GmbH Böblinger Strasse 17 71101 Schönaich, Germany Phone: (49) 7031 63701 Fax: (49) 7031 637493 http://ecc.emea.honeywell.com Subject to change without notice. Printed in Germany