Prestressed Concrete Pipe Fitness for Service and Repair

Similar documents
Retrofit Design of Damaged Prestressed Concrete Cylinder Pipes

Condition Assessment of a 48 PCCP Water Main Within an Abandon Subway Tunnel

Meeting the Challenge of Pipeline Emergency Repair

Using StrongPIPE Hybrid FRP for PCCP Rehab in Miami-Dade System

Session: HDPE Pipe Test Rafael Ortega, Vice President, Lockwood, Andrews & Newnam

Measuring the Condition of Prestressed Concrete Cylinder Pipe

WSSC Ad-Hoc Committee on Large Diameter Water Mains. August 2, 2013

External Wrapping of Steel Riser Pipe. Case Study HJ3 CS200902

CIPP for Large Diameter Pressure Pipes. Water Research Foundation Large Diameter Pipe Rehabilitation Seminar 20 January 2016 George Bontus, P.Eng.

Best Practices Manual for Prestressed Concrete Pipe Condition Assessment: What Works? What Doesn t? What s Next?

Strengthening of Large Storage Tank Foundation Walls in an Aggressive Environment by External Post-tensioning. May 7th 2013: Dominique Deschamps

The Original Carbon Fiber Reinforced Polymer System

Chesapeake Section AWWA Symposium

IS THAT LINER THICK ENOUGH?

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

Introduction to Pressure Pipe Rehabilitation with CIPP

REHABILITATION OF UNDERGROUND SEWER LATERAL PIPES WITH CURED-IN-PLACE-PIPE LINER SECTION 02542

Draft Table of Contents. Building Code Requirements for Structural Concrete and Commentary ACI

SPECIFICATIONS FOR SEWER PIPE AND LINING INSERTION - TRENCHLESS; GENERAL GUIDELINES (As Provided by NASSCO)

Structural Rehabilitation of the Kenilworth PCCP Transmission Main with Steel Slipliner

AGENDA ITEM C9. COST/FUNDING SOURCE: $431,847.40/ Uniform Rate

Pipeline Asset Management: From Assessment to Prioritized Projects List

North American Society for Trenchless Technology (NASTT) NASTT s 2014 No-Dig Show. Orlando, Florida April 13-17, 2014

Force Main Condition Assessment: New Technologies & Case Studies

beams columns blast walls slabs pipes protective coatings polymer concrete Solutions Looking for Problems...

In-situ Load Testing to Evaluate New Repair Techniques

Oil and Gas Pipeline Design, Maintenance and Repair

SECTION PRESTRESSED CONCRETE CYLINDER PIPE

SEISMIC RETROFITTING TECHNIQUE USING CARBON FIBERS FOR REINFORCED CONCRETE BUILDINGS

Structural Rehabilitation of Rigid Pipes. George McAlpine 1, Affiliate, ASCE

Field Damage Inspection and Static Load Test Analysis of Jiamusi Highway Prestressed Concrete Bridge in China

A Decade of Performance of FRP-Repaired Concrete Structures

Fire-Damage or Freeze-Thaw of Strengthening Concrete Using Ultra High Performance Concrete

Relining of Water Mains with. Flexible High Pressure Pipelines. Raedlinger Primus Line, Inc. Ivan Zubiaga Executive Vice President 2014

Before H 2 Town of South Windsor, CT Evaluates Large Diameter Concrete Pipe

PROVIDING THE SAFE CHOICE FOR UNDERGROUND PIPE RENEWAL, INTEGRITY MANAGEMENT AND ASSET RELIABILITY

PIPE REHABILITATION. Industrial Wastewater Municipal Wastewater Drinking Water Pressure Pipes

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

Condition assessment and repair of antenna towers concrete foundations

Technical Notes 3B - Brick Masonry Section Properties May 1993

APE T CFRP Aslan 500

ASTM D 1599 Standard Test Method for Resistance to Short-Time Hydraulic Pressure of Plastic Pipe, Tubing, and Fittings

Flowtite Jacking Pipe

ABSTRACT 1. INTRODUCTION 2. DESCRIPTION OF THE SEGMENTAL BEAM

Industrial Pipeline Integrity Management & Remote Polyurea Pipe Lining Systems.

MATERIALS AND MECHANICS OF BENDING

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

Chapter 5 Bridge Deck Slabs. Bridge Engineering 1

SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE

Composite Design Fundamentals. David Richardson

Engineered, Time-Tested Foundation Repairs for Settlement in Residential and Light Commercial Structures. The Leading Edge.

American Society of Civil Engineers

Protecting Your Pools Crack Treatments

Structural Testing of GeoPolymer Pipe/Culvert Lining

The Suitability of CRA Lined Pipes for Flowlines Susceptible to Lateral Buckling SUT Global Pipeline Buckling Symposium, February 2011

SECTION NONREINFORCED CONCRETE SEWER PIPE

1.3.2 Method of construction and restoration of existing water service connections. This shall include:

ASSESSMENT AND PROPOSED STRUCTURAL REPAIR STRATEGIES FOR BRIDGE PIERS IN TAIWAN DAMAGED BY THE JI-JI EARTHQUAKE ABSTRACT

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

City of Lincoln, Nebraska STEVENS CREEK BASIN TRUNK SEWER TECHNICAL MEMORANDUM NO. 5 PIPE MATERIAL SELECTION TABLE OF CONTENTS

Risk - Based Inspection Frequencies

Concrete Pressure Pipe

Fire Damage Evaluation. Concrete Garage. Vehicular fires in parking garages are not an

Experimental assessment of concrete damage due to exposure to high temperature and efficacy of the repair system

DIVISION 4300 STORM DRAINAGE

Structural Failures Cost Lives and Time

STRENGTHENING AND LOAD TESTING OF THREE BRIDGES IN BOONE COUNTY, MO

WORK SCOPE. Domains in which we work:

Published in Pipelines 2001 Proceedings of the Conference American Society of Civil Engineers Held July 15-18, 2001, San Diego, California

INSTALLATION OF INSITUFORM LINER

LOW VELOCITY IMPACT ANALYSIS OF LAMINATED FRP COMPOSITES

Deflection Calculation of RC Beams: Finite Element Software Versus Design Code Methods

1.5 Concrete (Part I)

Cylinder Head Gasket Contact Pressure Simulation for a Hermetic Compressor

Basics of Reinforced Concrete Design

Amendment 1 Preliminary Engineering Report for the City of Salida

HYDRAULIC ANALYSIS OF PIPE LINED WITH MADISON S 100% SOLIDS STRUCTURAL POLYURETHANE COATINGS

Comprehensive Design Example 2: Foundations for Bulk Storage Facility

High Performance PSA in Sheet Membrane in Water Protection

FOUNDATION DESIGN. Instructional Materials Complementing FEMA 451, Design Examples

Analysis and Repair of an Earthquake-Damaged High-rise Building in Santiago, Chile

Section Four: Linings and Coatings

REHABILITATION OF THE FIGUEIRA DA FOZ BRIDGE

Series 4000 Fiberglass Pipe and Fittings

LINER BUCKLING IN PROFILED POLYETHYLENE PIPES

CCTV PIPE INSPECTION AND EVALUATION RUNWAY 17L-35R

Outline MICROPILES SUBJECT TO LATERAL LOADING. Dr. Jesús Gómez, P.E.

LARGE DIAMETER PIPELINE INNOVATIVE FAST TRACKED REPAIR

49 CFR 192 Transportation of Natural and Other Gas By Pipeline: Minimum Federal Safety Standards

A transverse strip of the deck is assumed to support the truck axle loads. Shear and fatigue of the reinforcement need not be investigated.

Transcription:

Prestressed Concrete Pipe Fitness for Service and Repair Rasko Ojdrovic rpojdrovic@sgh.com 781-907-9231 IAEA - EPRI 15 October 2014 www.sgh.com

SGH Pipeline Experience More than 25 years of research, analysis, design, condition assessment, failure investigation and repair of pipelines Developed AWWA C304 standard for design of PCCP Developed AWWA M9 thrust restraint design procedure Developed procedure for risk assessment (fitness for service) of PCCP Developing standards for CFRP repair design of pipe

PCCP Distress Signs Coating cracks and delaminations Corrosion of prestressing wires Broken prestressing wires Longitudinal cracks in inner core Hollow sounding inner core Corrosion of steel cylinder Leak (through joints or steel cylinder)

Prestressing Wire Breakage Corrosion Embrittlement

Mortar Coating Petrographic Analysis Determine quality and condition after years of service Petrographic analysis and testing of polished and thin sections

Steel Pipe Mortar Lining 7

PCCP Condition Assessment What Works, What Doesn t, What s Next Water Research Foundation Project 04233 Provides utilities with a Best Practices Manual based on the available state-of-the-art condition assessment and service life estimation approaches for PCCP lines Most appropriate condition assessment technologies Best practice in condition assessment Limits of applicability of available technologies Wrote sections on inspection prioretization for Concrete pipe in EPRI report 1016456, Recommendations for an Effective Program to Control the Degradation of Buried and Underground Piping and Tanks, 2010, used by nuclear power plants

Likelihood of Failure Likelihood of Failure (Desktop) Review Pipeline Data: Age, Design, Manufacturing, Installation Environment, corrosivity Performance history Operation (working and trans. pressure) Analysis: Structural evaluation Failure margin analysis Optional Lower Cost Condition Assessment: Internal visual and sounding inspection External inspection/ material properties Over the line surveys Pipe stiffness testing Pipeline Condition Assessment Consider System Constraints Time the line can be out of service Dewatering time and cost Access cost for excavation Other Consequences of Failure Life safety and property damage Service interruption downstream Political costs Loss of public trust Determine Pipe Risk of Failure and Pipeline Criticality Risk of Failure Pipeline Criticality Low Consequence of Failure None Low Medium High Low Risk 1 1 2 2 Medium 1 2 2 3 High 1 2 3 High Risk 3 1 Low Risk/Criticality Perform economic analysis to select one of the following options: Do nothing / Run to failure Leak detection 2 Medium Risk/Criticality Perform economic analysis to select one or more of the following options to identify lower and higher risk portions of the pipeline: Internal visual and sounding inspection External inspection/ material testing Leak detection Pipe stiffness testing 3 High Risk/Criticality Perform economic analysis to select one or more of the following options to identify distressed pipe pieces and higher risk portions of the pipeline: Internal visual and sounding inspection External inspection/ material testing Leak detection Electromagnetic inspection Failure Margin Analysis/ Repair Prioretization Rehabilitation None Repair individual pipe pieces Rehabilitate pipeline section Update Pipeline Likelihood of Failure

Fitness for Service - Failure Margin Analysis of Distressed Pipe with Broken Wires Evaluate the effects of broken prestressing wires on the pipe failure margin using risk curves Establish pipe repair priorities (immediate, mid term, no repair) Identify high risk pipes for repair to maintain pipeline reliability Risk Curves Serviceability Limit State onset of visible cracking of core Damage Limit State core structural cracking and increase in wire stress adjacent to BWZ Strength Limit State pipe failure 10

Risk Curves - Repair Priority 2 RP3 + Serviceability RP4 Strength with contribution of soil Strength without contribution of soil Damage RP1 RP2 Repair Priority 2: Exceeds the damage limit state Does not exceed strength limit state Failure occurs with time Pipe should be repaired typically between now and five years

Basis of Failure Margin Analysis - Risk Curves Hydrostatic pressure tests of pipe with broken wires Non-linear and linear finite-element models of the failure of PCCP with broken wires subjected to combined internal pressure and external loads Field inspection of distressed pipe to characterize pipe condition near broken wire zones Risk curves technology (US Patent 7043373) 14

Hydrostatic Pressure Testing 15

Nonlinear Finite Element Analysis 16

Pressure (psi) Verification of Risk Curves Prestress fraction in BWZ rp 0 300 270 Strength 240 210 180 Damage 1A 150 120 4A 3A 2A 1B 90 Serviceability 60 1C 30 4B 3B 2B 0 0 20 40 60 80 100 120 140 160 180 200 220 240 Number of Broken Wires Serviceability limit state Damage limit state Strength limit state without soil resistance Strength limit state with soil resistance Cylinder ultimate strength Cylinder yield strength Pipe No. 5BH9 1996 Failed Pipe

Verification of Risk Curves 48 in. LCP, Canada

Repair and Rehabilitation Options Repair distressed pipe so that the repair pipe would have the desired strength, durability, reliability, and hydraulic performance Evaluate repair options including External Post-tensioning Pipe replacement with closure piece Replacement of a portion of the pipeline Concrete encasement External FRP repair Internal CFRP hand lay-up repair Steel or FRP liner HDPE slip-lining repair 19

CFRP Liners No need for external access >15 year track record Draft AWWA Standard and ASME Code Case in progress 20

Research basis for CFRP repair design 21

CFRP Design Approach Consider degradation level of host pipe Stand-alone versus composite design (with remaining host pipe) Use LRFD Circumferential Design Longitudinal Design Limit State Loads Limit State Loads CFRP Rupture Internal pressure + External gravity loads CFRP Rupture Internal pressure (Thrust, Poisson) + Temperature Buckling Debonding 22 External loads including Groundwater + Vacuum Empty pipe under external loads Debonding Buckling Internal pressure (Thrust, Poisson) + Temperature Temperature

The WaterRF Project Objective: Develop all necessary technical background for an LRFD-based AWWA Standard. 23 Time Effect Factor Resistance Factor Adjustment Factor R u = required strength computed from factored load combinations λ = time effect factor that accounts for creep rupture of material under sustained loads, ϕ = resistance factor that accounts for the variability of material properties and uncertainty in predictive formulas, R n = strength in the end-use condition, C = material adjustment factor that accounts for durability of material (i.e., retained strength) exposed to environment for the duration of its service life, and R o = Characteristic value of the test strength of material prior to exposure to the environment.

Load Combinations Circumferential Load Combinations 1.4 (P w + P t ) 1.4 (W e + W p ) 1.2 (W e + W p ) + 1.6 W t 1.4 (P w + W e + W p ) + W f 1.2 (P w +W e + W p ) + W f + 1.6 W t 1.2 (W e + W p ) + W f + 1.2 P w + 1.2 P t Buckling Load Combinations 1.4(P gw + W e * + W p *) 1.2(P gw + W e * + W p *) + 1.2P v 1.2(P gw + W e * + W p *) + 1.6W t Longitudinal Load Combinations 1.4P w + 1.2T + 1.4S + 1.4F 1.2P w + 1.2P t + 1.2T + 1.2S + 1.2F F = thrust-related axial force P w = working Pressure Pt = Transient Pressure P v = vacuum Pressure P gw = ground water pressure S = differential settlment T = temperature load W e = earth load W p = pipe weight W f = fluid weight W t = live load 24

Strength Depends on the number of layers 25

Durability - Retained Strength Data Courtsey of Fyfe Company 26

Material Adjustment Factor, C 50-yr. Exposure Water Salt Solution Alkali Solution Water 5-yr. Exposure Salt Solution Alkali Solution Tension Flexure Short-Beam Shear Pull-Off Strength In-Plane Shear Strength Modulus Strength Modulus Strength Strength Strength Modulus 73 F 0.85 0.95 0.7 0.9 0.7 0.7 0.75 0.8 100 F 0.85 0.95 0.6 0.85 0.6 0.6 0.6 0.7 140 F 0.7 0.95 0.45 0.85 0.5 0.5 0.55 0.6 73 F 0.75 0.95 0.7 0.85 0.7 0.5 0.75 0.45 73 F 0.75 0.95 0.65 0.80 0.7 0.8 0.75 0.45 Tension Flexure Short-Beam Shear Pull-Off Strength In-Plane Shear Strength Modulus Strength Modulus Strength Strength Strength Modulus 73 F 0.90 1.0 0.85 0.95 0.85 0.85 0.85 0.90 100 F 0.90 1.0 0.75 0.90 0.75 0.75 0.75 0.85 140 F 0.80 1.0 0.60 0.90 0.65 0.65 0.70 0.75 73 F 0.85 0.95 0.85 0.90 0.85 0.65 0.85 0.65 73 F 0.90 0.95 0.80 0.85 0.85 0.85 0.85 0.65 27

Summary of target reliability indices (β) and resistance factors (ϕ) Limit State β φ CFRP laminate rupture in axial tension/compression in either direction 3.5 0.75 CFRP laminate rupture in bending in circumferential direction 3.5 0.70 CFRP laminate rupture in bending in longitudinal direction, at BWZ edge 3.5 0.75 CFRP laminate buckling in circumferential direction 3.0 0.55 CFRP laminate buckling in longitudinal direction 3.0 0.75 CFRP debonding from steel substrate at pipe ends due to shear 3.0 0.75 CFRP debonding from steel substrate at pipe ends governed by CFRP strain 3.0 0.90 CFRP debonding from concrete inner core due to radial tension 3.0 0.50 CFRP debonding from concrete inner core due to shear 3.0 0.60 28

FEA Validation Analyzed 10 Different PCCPs, ranging in type, diameter, concrete strength, cylinder thickness, wire diameter, earth load, and pressure. Prestress was based on design, CFRP by AWWA Standard for CFRP Renewal and Strengthening of PCCP. 29

Comparison of FEA and Design Equations 60 in. ECP, H = 6 ft, P w = 100 psi, P t = 40 psi, and M s = 3,000 psi Item Load FEA AWWA Draft Standard Thrust at springline (lb./in.) Comment Earth load and pipe weight -242-247 AWWA is in agreement Horizontal deflection (in.) Earth load and pipe weight 0.10 0.17 AWWA is conservative Earth load and pipe weight 27 331 AWWA is conservative Maximum Strain in CFRP at invert (με) Earth load, pipe weight and working pressure 910 (1,252) 1,278 AWWA is conservative Earth load, pipe weight and working plus transient pressure 1,350 (1,614) 1,660 AWWA is conservative 30

Constrained Buckling of CFRP Liner Glock Equation for Liner Buckling inside a Rigid Pipe: P cr,gluck = P cr E 2 1 t D 2.2 Runs made for a range of different pipes and soils show P cr, FEM /P cr,glock =0.70 to 0.82 31

Experimental Study Hydrostatic pressure Tests on 6 pipes (3 ECP and 3 LCP) Three-edge bearing tests on 8 pieces (1 control with no liner, four pieces of 48 in. LCP and three pieces of 54 in. ECP). The results of experimental study was introduction of new failure modes/limit states: Longitudinal bending of CFRP laminate at the edge of BWZ. Loss of CFRP laminate/steel bond failure Loss of watertightness of the CFRP laminate. Delamination is very sensitive to CFRP laminate/concrete bond strength 32

Hydrostatic Pressure Testing and Three-Edge Bearing Test 33

Loss of Watertightness 34

How to Ensure Watertightness? By testing of the laminate By introducing a watertight layer By curing to close to 100% By replacing introducing an alternate for thickened epoxy used for surface preparation and final coating. Watertightness Test apparatus 35

Summary Presented basis of fitness for service of distressed PCCP and verification of results FEA alone is not sufficient to evaluate PCCP failure Presented basis of CFRP repair design Not the same as steel 36

Thank you Questions? Rasko Ojdrovic rpojdrovic@sgh.com 781-907-9231