Protecting Your Pools Crack Treatments
|
|
|
- Reginald Robertson
- 10 years ago
- Views:
Transcription
1 1 Protecting Your Pools Crack Treatments Scuba Pool Repair Inc. 800 Cristich Lane Campbell, CA Phone: Fax: Scuba Pool Repair Inc. Protecting Your Pool-Cracks Treatment Page 1
2 2 TABLE OF CONTENTS Page No. 1. Why do pools crack Cracks and leak Why choose Scuba Pool Repair for crack treatment References...11 Scuba Pool Repair Inc. Protecting Your Pool-Cracks Treatment Page 2
3 3 Why do pools crack? Although many swimming pools look similar in lots of fundamental ways, every one of them is actually quite unique. From groundwater and soil conditions or the specifics of their structural designs to the methods in which they have been installed, water-containing vessels of all shapes, types and sizes are, in fact, subject to a wide array of location- and workmanship specific variables that can influence the way their concrete shells will perform through the years. When a water shape cracks, any number of things might have gone wrong. To the owner of a pool such cracking is obviously a source of concern. There are many reasons why your pools crack. The most common cause of pool cracks is ground movement. Certain construction issues and temperature change, while not common, can also cause pools to crack. Soil shifting, flooding, and freezing temperatures are all conditions that negatively affect the structural integrity of your pool. Another common reason is the poor workmanship that went into constructing the pool 1. Soil shifting occurs when a structure was constructing on unstable soil. When the soils shift, it affects the foundation of the pool causing it to crack. 2. Change in temperature will also influence the structure s condition of the pool. Temperature change will make the structure s concretes and steel bars to expand and contract rapidly causing cracking on the surface of the pool. 3. For all of the variables introduced by soils conditions and groundwater intrusion, there are times when the real problem leading to a cracked shell is a failure of workmanship. Improper gunite or shotcrete application especially in the form of inadequate coverage of reinforcing steel is probably the most common of these issues Scuba Pool Repair Inc. Protecting Your Pool-Cracks Treatment Page 3
4 4 Cracks and Leak Some of the most common types of cracking result from substandard workmanship. This can include improper gunite or shotcrete application or seemingly minor oversights when installing the concrete pool deck. The four most common types of workmanship-related cracking are: Horizontal cracking in the waterline tile What it looks like: This is the most common type of cracking found in pools, and it looks just like the name indicates. What causes it: The concrete deck is not completely separated from the pool's bond beam. The deck moves, putting pressure against the pool wall. As a consequence, the pool's bond beam may crack. If waterline tile is affixed to the problem area, the tile will fracture as well. Similar cracking can result from a common technique used to prepare for the coping. Workers level the top of the bond beam by applying a layer of mortar. If the material doesn't properly affix to the beam, it may delaminate, causing the tile in front of it to crack. How to prevent it: Completely separate the concrete deck from the pool's bond beam. An expansion joint must extend the full depth of the deck. For example, if your deck is 4 inches thick, the expansion joint must be 4 inches deep. This prevents the two bodies from touching. To ensure proper adhesion between the bond beam and that leveling layer of mortar, follow proper workmanship procedures. Moisten and clean the beam before applying the mortar. Scuba Pool Repair Inc. Protecting Your Pool-Cracks Treatment Page 4
5 5 How to fix it: In either case, the pool builder must remove and replace the cracked materials using proper trade procedures. Often, workers must retile the waterline as well. Reflective cracking What it looks like: Cracks generally follow the pattern of the reinforcement or piping inside the wall. Older cracks may show rust. What causes it: The reinforcing steel is inadequately covered or improperly encased. This usually stems from one of several possible mistakes: The shotcrete mix didn't have enough moisture wasn't shot at a high-enough velocity, or the nozzle man didn't use proper techniques. These errors can result in voids or shadows behind the reinforcing steel. The rebar wasn't properly secured, so it vibrated during gunite or shotcrete application. This prevents the gunite or shotcrete from adhering to the reinforcement. The gunite or shotcrete was applied too thinly over the reinforcement. This can especially be a problem on freeform pools, where crews can't set vertical and horizontal string lines to help establish the right thickness. How to prevent it: Use the proper gunite or shotcrete mix, and apply it at the right velocity and thickness. How to fix it: If the cracks aren't too old, they can be injected with an epoxy that is stronger than the concrete itself. Older cracks, however, will have exposed the steel to water, resulting in rust and corrosion. In this case, the area will have to be torn apart and redone. Delamination Scuba Pool Repair Inc. Protecting Your Pool-Cracks Treatment Page 5
6 6 What it looks like: Alligator cracking or separation of the outer layer. What causes it: Several errors can cause delamination. Rebound, a byproduct of applying gunite or shotcrete, is a primary culprit. As crews shoot the concrete, some pieces of aggregate bounce off the wall and fall out to the floor. Some builders use it to build steps or benches, or otherwise bury it in the pool shell. However, rebound doesn't have enough cement to form a proper bond, so it may delaminate. Delamination can also be caused by "flashing" when the applicator conceals rebound or a surface flaw by putting a thin layer of gunite or shotcrete over the area. It may not bond properly. How to prevent it: Keep rebound out of the pool. Haul it off the property. Avoid flashing if possible. How to fix it: Workers must strip away the delaminated area and replace it, making sure it bonds properly to the surface underneath. Shrinkage cracking What it looks like: There's no set pattern. These cracks are intermittent, random, and angular, generally running throughout the pool. They are typically shallow. Scuba Pool Repair Inc. Protecting Your Pool-Cracks Treatment Page 6
7 7 What causes it: Improper curing or excessive moisture in the gunite or shotcrete. How to prevent it: Avoid the temptation to add water to the proper shotcrete or gunite mix. After the material is applied, properly hydrate it so it can cure sufficiently. These are the predominant forms of soils-related cracking: Differential movement cracking What it looks like: Cracks are usually vertically oriented. They are often wider at the top of the pool wall and get narrower as they move toward the floor. What causes it: Having two different types of soil underneath the pool can cause differential movement cracking. This may occur naturally if, for example, the yard has both bedrock and a softer soil. Or it could result from a cut/fill transition when the pool straddles backfill and native soil. This can be a problem even if the fill has been properly compacted. Unless the pool Scuba Pool Repair Inc. Protecting Your Pool-Cracks Treatment Page 7
8 8 rests on uniform earth, the softer material will compress more than the harder, causing unequal movement. The pool may crack from the uneven support. How to prevent it: A soils engineer should examine the site if the home builder does any recompacting or the pool excavation reveals two different kinds of material. A structural engineer may need to design a support system for the pool. How to fix it: Based on experience, epoxy injection will work 60 percent to 70 percent of the time after ground movement has run its course. If the soil is expansive or otherwise continues to move, the pool may crack again. Slope creep cracking What it looks like: Very similar to differential movement cracking. What causes it: On some hillsides, a 10- to 15-foot layer on the face of the slope will slowly move downward. Generally this happens with expansive soil. You can detect slope creep when trees or other vertical elements on the hillside point outward rather than straight up. How to prevent it: Hire both soils and structural engineers to examine any hillside property. The soil can be identified and a proper support system engineered. How to fix it: This very costly repair requires demolishing part of the pool and installing a footing or key to increase the setback from the foundation to the face of the slope. Expansive soil cracking What it looks like: Cracking located on the pool floor. In the most severe cases, the pool is thrust out of the ground. Scuba Pool Repair Inc. Protecting Your Pool-Cracks Treatment Page 8
9 9 What causes it: Highly expansive soils aggressively pushing upward on the pool. How to prevent it: Again, hire a soils engineer. If the professional detects expansive soils, a structural engineer can adapt the shell. Solutions will range from thickening the pool floor to building a pier-and-grade-beam foundation. How to fix it: You could try epoxy injection and cross your fingers. If that doesn't work, you may have to remove the floor and add more steel and gunite as specified in an engineer's plans. Not all cracks need to be addressed as emergencies so let Scuba Pool Repair perform a dye test to see if they are indeed cause for immediate concern. We will pinpoint and repair leaking cracks before they become unmanageable. Severe cracking can be the source of water loss in your pool. If your pool is leaking water, in extreme circumstances, the structural integrity of your pool may be compromised and therefore also deserves immediate attention. Scuba Pool Repair is qualified to address these issues as well. Scuba Pool Repair Inc. Protecting Your Pool-Cracks Treatment Page 9
10 10 What is crack repair? The focus of crack repair is to prevent further leakage of water through existing pool cracks. In some cases, the structural integrity of the pool will also be addressed. Will the fix be permanent? Since all crack situations are different, there is no guarantee that the fix will be permanent. Unless the cause of the crack is identified and addressed, the pool may continue to crack. Do all cracks need to be repaired? Surface cracks are not uncommon in swimming pools. If there is water loss in the pool, these cracks can be dye tested to see if they are leaking. Surface cracks that do not leak do not necessarily need to be repaired. Scuba Pool Repair Inc. Protecting Your Pool-Cracks Treatment Page 10
11 11 Why choose Scuba Pool Repair for your crack treatment? Scuba Pool Repair has been in business for over 21 years. We continue developing and perfect our underwater techniques. We have been serving and keeping our communities pools and spas safe since Satisfaction and loyalty from our customers are Scuba Pool Repair goals. Scuba Pool Repair s technicians are fully trained on crack treatments. We repaired hundreds of crack per year and no matter how big or small the crack is, there is no crack that we can t repair. We have extensive experience with residential, commercial and public pool. We also do not drain your pool in order to repair the cracks. Draining the pool to do repair will expose the pool to more complications and might lead to further cracking. Scuba Pool Repair has helped save California thousands of gallons of water per year by doing repair underwater. We can help you save money, conserve water and help protecting your pool as well as the environment. Important: Because we cannot control the movement that causes cracking, cracks are warranted for 30 days. There is no guarantee that the plaster patch will match the existing plaster but it will be as close as possible During the repair process, the pool stays the same. We do not drain the pool whatsoever. Empty pools are inherently dangerous. It is the homeowner s responsibility to ensure that all sprinkler systems are turned off and that small children and pets are kept away from the empty pool. Is your pool leaking water? Let us help you determine when leaks are serious enough to require repair. Scuba Pool Repair will evaluate with you on how to determine exactly where and how severe your leak is. Once this area is located, our expert technicians will take the appropriate actions to fix the problem. One phone call is all it takes to get your pool back in proper working order. Our goal is to help you enjoy your pool without interruption. Scuba Pool Repair Inc. Phone: Fax: [email protected] Scuba Pool Repair Inc. Protecting Your Pool-Cracks Treatment Page 11
12 12 References 1. Custom Home Magazine. Publication date: By Rebecca Robledo 2. Soil Considerations in Swimming Pool Construction, by Ron Lacher, P.E. Pool Engineering, Inc. Scuba Pool Repair Inc. Protecting Your Pool-Cracks Treatment Page 12
Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing
1 Most basements show some signs of leaking and cracking. Through the years, problems with water, poor soils, grading, drainage and possible settling affect the integrity of a basement. Being able to recognize
DAMAGE TO FOUNDATIONS FROM EXPANSIVE SOILS
DAMAGE TO FOUNDATIONS FROM EXPANSIVE SOILS J. David Rogers, Robert Olshansky, and Robert B. Rogers Expansive soils in many parts of the United States pose a significant hazard to foundations for light
symptoms of a faulty foundation
symptoms of a faulty foundation How does drought impact your home's foundation? For many Texas families, their home becomes the single largest investment and also the family fortune. The home's foundation
Foundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training
Foundations 65 5 FOUNDATIONS by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. 66 Foundations Foundations 67 FOUNDATIONS Let's assume that the retrofit has been done correctly from the roofline
Designed and Engineered to Perform
History EARTH CONTACT PRODUCTS, L.L.C., is a family owned company, based in Olathe, Kansas. This company was built upon Don May s U.S. Patented fourth-generation Steel Piering System that has led to the
GOOD NEWS BUT NOT ALWAYS
GOOD NEWS BUT NOT ALWAYS The prospective homebuyer and homeowner in the Amarillo area are indeed fortunate. Typically, he has a wide choice of type home, size, and location for wide ranges of pricing.
Section 02702 SEWER PIPE INSTALLATION AND TESTING
PART 1 - GENERAL Section 02702 SEWER PIPE INSTALLATION AND TESTING 1-1. SCOPE. This section covers the installation and testing of all sewer pipe furnished under the following specification sections: Concrete
Investigation of Foundation Failure. Step 1 - Data Collection. Investigation Steps
Foundations on Expansive Clay Soil Part 3 - Investigation of Failed Foundations Presented by: Eric Green, P.E. Structural Engineer Slide 1 Copyright Eric Green 2005 Investigation of Foundation Failure
Chapter 9 Remedial Measures
[This is an annotated version of a chapter from the US Army Corps of Engineers book, Foundations in Expansive Soils. This book is in the public domain. This document is consists of an abbreviated and annotated
Meeting the Challenge of Pipeline Emergency Repair
Meeting the Challenge of Pipeline Emergency Repair Michael R. McReynolds, PE, SE 1 Tao Peng, PE, SE 2 ABSTRACTS The Metropolitan Water District of Southern California (MWD) is the nation s largest provider
Foundation Repair Fundamentals And how they relate to the Real Estate Industry in the DFW Area
Foundation Repair Fundamentals And how they relate to the Real Estate Industry in the DFW Area Presented by MBRGFR.COM www.mbrgfr.com Office: 817-469-1090 E-mail: [email protected] Objectives: I: Understanding
Foundation Code compliance and Best Practices By Michael Coello
Foundation Code compliance and Best Practices By Michael Coello Background Graduated cum laude in 1992 with a Bachelor of Science degree in finance from University of Wisconsin - Parkside Started poured
September 1, 2003 CONCRETE MANUAL 5-694.900 CONCRETE PAVEMENT REHABILITATION 5-694.900
September 1, 2003 CONCRETE MANUAL 5-694.900 5-694.901 GENERAL CONCRETE PAVEMENT REHABILITATION 5-694.900 Concrete Pavement Rehabilitation is an extremely valuable tool of the Minnesota Department of Transportation
Cold Weather Concrete Practices
Cold Weather Concrete Practices The Information below is an outline of common practice for residential foundation placement and winter construction utilize Edmonton and surrounding Area. Conditions in
What you need to know about concrete block basement construction.
Designing and planning your new residence is a vitally important process, which will have a great influence on the future enjoyment of your home. A successful process will ensure all areas of the home
Moving Small Mountains Vesuvius Dam Rehab
Moving Small Mountains Vesuvius Dam Rehab Susan L. Peterson, P.E., regional dams engineer, Eastern Region, Bedford, IN Note: The following article, Moving Small Mountains Vesuvius Dam Rehab, by Sue Peterson,
Waterproofing Problems: A Simple Explanation, A Simple Solution
Waterproofing Problems: A Simple Explanation, A Simple Solution The purpose of this paper is to point out the underlying causes of waterproofing problems and simple means of preventing them. Such problems
SIDE SEWER CONDITION ASSESSMENT AND REPAIR RECOMMENDATIONS
SIDE SEWER CONDITION ASSESSMENT AND REPAIR RECOMMENDATIONS Introduction City of Tacoma property owners are responsible for the construction, maintenance and repair of private side sewers, which connect
Coexisting with Expansive Soil. An Informational Guide for Homeowners
Coexisting with Expansive Soil An Informational Guide for Homeowners Overview Homes in California are built on a variety of soil types with differing characteristics that can affect homes and surrounding
National Home Builder - Name Wednesday, August 20, 2014 Regional Customer Care Manager 1234 Main Street Houston, Texas 77067
Lighthouse Engineering, L.L.C. Michael Gandy, P.E. Registered Professional Engineer (TX: 95672) Registered Engineering Firm (F: 9334) Phone: 214-577-1077 Fax: 214-224-0549 Website: www.lighthouseeng.com
NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)
NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:
R E S I D E N T I A L H O U S I N G
HL 252 Rev. April 1997 R E S I D E N T I A L H O U S I N G CONTROLLING EXTERNALWATER PROBLEMS FOR RESIDENCES I II III IV V Lot Drainage Gutter Water Management Foundation Waterproofing Floor Slab Waterproofing
Measuring the Condition of Prestressed Concrete Cylinder Pipe
Measuring the Condition of Prestressed Concrete Cylinder Pipe John Marshall, P.E.I, I J.W. Marshall and Associates, and Paul S. Fisk, President NDT Corporation Introduction Prestressed Concrete Cylinder
External Wrapping of Steel Riser Pipe. Case Study HJ3 CS200902
External Wrapping of Steel Riser Pipe Case Study HJ3 CS200902 Introduction Refineries process a wide variety of petroleum products. As part of the process, they rely on cooling towers, which recycle water
What Causes Foundation Leaking?
A home's foundation has the odds stacked against it from the day it's built. When a home is excavated to make room for the foundation walls, space is left between the outer edge of the foundation wall
Foundation Water Problems. An Overview and Discussion of some Causes and Cures for Water Infiltration into Basements and Foundation Structures
Foundation Water Problems An Overview and Discussion of some Causes and Cures for Water Infiltration into Basements and Foundation Structures This presentation was prepared and presented by Dwight Walker
3 Masonry and Manufactured Stone (Interior and Exterior)
3 Masonry and Manufactured Stone (Interior and Exterior) 3.1 Efflorescence (a whitish crystalline powder) is present on masonry surfaces. Efflorescence commonly occurs on masonry surfaces. This is not
Homeowner s Guide Foundation Water PenetrationTips TIPS TO IDENTIFY WATER PENETRATION PROBLEMS / CRACKING BASEMENTS
Homeowner s Guide Foundation Water PenetrationTips TIPS TO IDENTIFY WATER PENETRATION PROBLEMS / CRACKING BASEMENTS MAINTAINING YOUR HOME BASEMENT FOUNDATION BY HOMEOWNER PREVENTATIVE MAINTENANCE LUX WATERPROOF
STRUCTURES. 1.1. Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL.
STRUCTURES 1. General. Critical structures may impact the integrity of a flood control project in several manners such as the excavation for construction of the structure, the type of foundation, backfill
Basement & Foundation Damage
Basement & Foundation Damage Please note-this presentation is only intended to be used as a basic educational tool and is by no means all encompassing. Each property should be treated on a case by case
HEDDERMAN ENGINEERING, INC. www.heddermanengineering.com Office 281-355-9911, Fax 281-355-9903 [email protected]
HEDDERMAN ENGINEERING, INC. www.heddermanengineering.com Office 281-355-9911, Fax 281-355-9903 [email protected], 2011 TO: Mr. REF: CONDITION OF PROPERTY SURVEY Dear Mr. : At your request,
Condition assessment and repair of antenna towers concrete foundations
Condition assessment and repair of antenna towers concrete foundations I. Banjad Pecur, N. Stirmer & B. Milovanovic Department of materials, Faculty of Civil Engineering, University of Zagreb, Zagreb,
Chapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
Chapter. Earthquake Damage: Types, Process, Categories
3 Chapter Earthquake Damage: Types, Process, Categories Earthquakes leave behind a trail of damage and destruction. People s lives are affected by the loss of loved ones, destruction of property, economic
Baton Rouge Foundation Repair
Baton Rouge Foundation Repair 13822 Florida Blvd Bldg 3 Baton Rouge, LA 70819 Baton Rouge Foundation Repair offers services to correct the settlement of both Slab foundations and Pier & Beam foundations
EAST LYME HIGH SCHOOL
Overview: 1971 N 1966 GYM 1966 CLASSROOM WING 1966 AUD. 1971 GYM 1998 1998 POOL EAST LYME HIGH SCHOOL Original 1966 Building: The original East Lyme High School was constructed in 1966 and was composed
SECTION 36 - CAST-IN-PLACE CONCRETE PIPE (CIPCP) TABLE OF CONTENTS
SECTION 36 - CAST-IN-PLACE CONCRETE PIPE (CIPCP) TABLE OF CONTENTS Section Page 36-1 GENERAL... 36.1 36-2 PIPEMAKING EQUIPMENT... 36.1 36-3 TRENCH EXCAVATION... 36.1 36-4 SPECIAL FOUNDATION TREATMENT...
Chapter. Restoration of Damaged Structures
5 Chapter Restoration of Damaged Structures Bringing back a damaged structure to its pre-earthquake state and original strength is called restoration. This is the first step of building rehabilitation.
Common Perils of Ceramic Floor Tile Systems. Parkway, Suite 220, Plano, Texas 75093; PH (469) 429-9000; email: bbarrett@architecturalengineers.
Common Perils of Ceramic Floor Tile Systems Bart B. Barrett, P.E. 1 and James M. Falls, E.I. 2 1 Central Florida Branch Director, Nelson Architectural Engineers, Inc., 2740 Dallas Parkway, Suite 220, Plano,
TITLE: MASONRY PARAPET WALLS AND FLAT ROOF REQUIREMENTS 11/1/09
TITLE: MASONRY PARAPET WALLS AND FLAT ROOF REQUIREMENTS 11/1/09 PMT GUIDE # 10 Book of Order Section G-10.0102o: "The session is responsible for the mission and government of the particular church. It
RACKING AND ATTACHMENT CRITERIA FOR EFFECTIVE MEMBRANE ROOF SYSTEM INTEGRATION Public Version 1: July 9, 2012
RACKING AND ATTACHMENT CRITERIA FOR EFFECTIVE MEMBRANE ROOF SYSTEM INTEGRATION Public Version 1: July 9, 2012 Commercial rooftops represent the most available, sustainable and secure real estate for new
1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona
for Earthen Material and Straw Bale Structures SECTION 70 - GENERAL "APPENDIX CHAPTER 7 - EARTHEN MATERIAL STRUCTURES 70. Purpose. The purpose of this chapter is to establish minimum standards of safety
State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS
State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS While its use is not required, this checklist has been prepared to provide the field inspector a summary
Specifications for Residential Property Owners Connection to New Public Sewer
Specifications for Residential Property Owners Connection to New Public Sewer Spalding Tract property owners are required to connect to the community sewer system when construction is complete and the
The minimum reinforcement for the stem wall is the placement of:
PolySteel creates an ideal insulated stem wall for concrete slabs that can make this part of your project easier and faster, in addition to making your finished project more energy-efficient. Figures 3.20
High Performance PSA in Sheet Membrane in Water Protection
High Performance PSA in Sheet Membrane in Water Protection Xia Cao, Senior R&D Chemist, W. R. Grace, Cambridge MA 02140 Jyoti Seth, Strategic Program Leader, W. R. Grace, Cambridge MA 02140 Concrete is
How To Replace A Roofing System In Florida
Florida Consumer Considerations in Replacing their Roofing System The Florida Roofing, Sheet Metal and Air Conditioning Contractors Association provides the following general information to help Florida
COPYRIGHT. Dincel Construction System Pty Ltd
BASEMENT CONSTRUCTION Dincel Construction System Pty Ltd 101 Quarry Road ERSKINE PARK NSW 2759 PO Box 104, ST CLAIR NSW 2759 Phone: (612) 9670 1633 Fax: (612) 9670 6744 Email: [email protected]
Basement Moisture Problems
Foundations Foundation Purpose The purpose of a foundation is to distribute the weight of a structure securely into the ground. Engineering data regarding soil, rock and water conditions are used to design
BUTE Department of Construction Management and Technology
BUTE Department of Construction Management and Technology 02.10.2012 Definition 1: Foundation: The structure, that transmits the load of the building to the soil Definition 2: Load bearing soil (strata):
BEST MANAGEMENT STANDARDS FOR FOUNDATION REPAIR MARCH 2003 REVISED JUNE 13, 2012
BEST MANAGEMENT STANDARDS FOR FOUNDATION REPAIR MARCH 2003 REVISED JUNE 13, 2012 Prepared in cooperation with the Building Inspectors Association of Southeastern Wisconsin www.biasew.net 1 BEST MANAGEMENT
WATERPROOFING OF WET ROOMS
WATERPROOFING OF WET ROOMS Waterproofing under tiles For longterm enjoyment of a wetroom area a complete and resistant waterproofing system is an important precondition. Most tiles are by themselves waterproof
BRIDGES ARE relatively expensive but often are
Chapter 10 Bridges Chapter 10 Bridges Bridg Bridges -- usually the best, but most expensive drainage crossing structure. Protect bridges against scour. BRIDGES ARE relatively expensive but often are the
INSPECTION PROPERTY ADDRESS: Fort Bend County, Texas
5006 Cherry Ridge Road Richmond, Texas 77406 281-342-9944 [email protected] INSPECTION PROPERTY ADDRESS: INSPECTION PERFORMED FOR: XXXX Drive Fort Bend County, Texas Mr. and Mrs. New Construction
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
Concrete Repair. Applications and Procedures
Concrete Repair Applications and Procedures Objectives Identify what surface preparation is needed Identify typical modes of failure and testing methods How to choose the correct material for the repair
Building Your Interlocking Concrete Pavement to Last a Lifetime
Building Your Interlocking Concrete Pavement to Last a Lifetime A Guide for Consumers Contents Building Your Interlocking Concrete Pavement to Last a Lifetime.... 3 What Does Installation Involve?....
Building Foundation and Structure
Building Foundation and Structure Overview The construction of the Hall of Waters building began in 1936, and was constructed over the original site of the Siloam and Sulpho-Saline Springs. The original
5006 Cherry Ridge Road Richmond, Texas 77406 281-342-9944 [email protected] LIMITATIONS AND DISCLAIMERS
5006 Cherry Ridge Road Richmond, Texas 77406 281-342-9944 [email protected] INSPECTION PROPERTY ADDRESS: INSPECTION PERFORMED FOR: XXXX Court Richmond, Texas Mr. Foundation Concerns INSPECTION DATE:
7 Crucial Questions to Ask Before Repairing Your Home s Foundation
7 Crucial Questions to Ask Before Repairing Your Home s Foundation A free report to help you understand your home s foundation and the foundation repair process 1 How can I tell if I have foundation damage?
Prestressed Concrete Pipe Fitness for Service and Repair
Prestressed Concrete Pipe Fitness for Service and Repair Rasko Ojdrovic [email protected] 781-907-9231 IAEA - EPRI 15 October 2014 www.sgh.com SGH Pipeline Experience More than 25 years of research, analysis,
Engineered, Time-Tested Foundation Repairs for Settlement in Residential and Light Commercial Structures. The Leading Edge.
TM TM Engineered, Time-Tested Foundation Repairs for Settlement in Residential and Light Commercial Structures. SM The Leading Edge. 10 One Major Causes of foundation settlement or more conditions may
June 2007 CHAPTER 7 - CULVERTS 7.0 CHAPTER 7 - CULVERTS 7.1 GENERAL
7.0 7.1 GENERAL For the purpose of this manual, culverts are defined as structures that are completely surrounded by soil and located below the surface of the roadway parallel to the general direction
SAMPLE REPORT. Convention regarding directions: Front faces the street, left and right are as seen from the street facing the house.
SAMPLE REPORT Gerard J. Duhon, P.E., #XXXXX Engineered Foundation Solutions, #X-XXXX ENGINEERING OPINION INVESTIGATION OF FOUNDATION PERFORMANCE RESIDENCE AT XXXXXXXX WAY, HOUSTON, TEXAS, 77084 Date of
Cupped Floor STEP 1. Flooring absorbing excessive moisture on the underside causes expansion and cupping with the edges raised.
BEHAVIOR OF FLOORING If it s not marked NOFMA, it s not certified. Cupping and Crowning Cupped Floor STEP 1. Flooring absorbing excessive moisture on the underside causes expansion and cupping with the
Roof Inspection. Summary Report
Phone: (561) 866 9956 www.real-estate-inspections.com Roof Inspection Summary Report Subject Property File Number: 05-15-RF-002 Inspector: Craig Milliken, PE CPM Real Estate Inspections, Inc. Date of Inspection:
TECHNICAL SPECIFICATIONS CONCRETE SIDEWALKS, DRIVEWAYS AND CURB AND GUTTER
TECHNICAL SPECIFICATIONS CONCRETE SIDEWALKS, DRIVEWAYS AND CURB AND GUTTER I. Scope of Work Work done under this item shall consist of the construction, reconstruction, or alteration of a one-course Portland
Wastewater Capital Projects Management Standard Construction Specification
CITY AND COUNTY OF DENVER ENGINEERING DIVISION Wastewater Capital Projects Management Standard Construction Specification 10.1 Precast Concrete Pipe 10.1.1 General This section covers material requirements,
bout your HOUSE before you start Renovating Your Basement Structural Issues And Soil conditions
A bout your HOUSE before you start Renovating Your Basement Structural Issues And Soil conditions CE 28 b Ground slopes towards window well No granular fill or connection to footing drain Ground floor
SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE
SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel
Product Application Sheet
Pool Shell Preparation The interior cementitious finish of a pool is the only cosmetic part of a pool that is handcrafted in an uncontrolled environment. For this reason it is absolutely imperative that
Jackson Gulch Outlet Canal Rehabilitation Project
Jackson Gulch Outlet Canal Rehabilitation Project Preliminary Budgetary Estimate for Rehabilitation February 2004 Prepared for the Mancos Water Conservancy District Jackson Gulch Reservoir 42888 County
738-B-297 POLYMERIC CONCRETE BRIDGE DECK OVERLAY. (Adopted 02-20-14)
POLYMERIC CONCRETE BRIDGE DECK OVERLAY (Adopted 02-20-14) Description The polymeric concrete bridge deck overlay shall consist of an epoxy polymer that acts together with special aggregate to form an overlay
Rehabilitation of an Aging Concrete Reservoir Adit Tower
Rehabilitation of an Aging Concrete Reservoir Adit Tower Raymond S. Tombaugh, Senior Coatings Consultant KTA-Tator, Inc. and Mongkol Mahavongtrakul, P.E. Corrosion Control Contract Manager San Francisco
STEPS TO CONSTRUCTING A MOISTURE-RESISTANT FOUNDATION SOURCES OF MOISTURE IN NEW CONSTRUCTION. Natural ground slope
FOUNDATIONS STEPS TO CONSTRUCTING A MOISTURE-RESISTANT FOUNDATION Build a Better Home Details are critical when constructing a sound building foundation that will withstand water and control dampness.
APPENDIX B. I. Background Information
APPENDIX B GUIDELINES FOR IDENTIFYING AND REPAIRING LOCALIZED AREAS OF DISTRESS IN AC PAVEMENTS PRIOR TO CAPITAL PREVENTIVE MAINTENANCE OR REHABILITATION REPAIRS I. Background Information A. AC Pavement
ENGINEERED FOUNDATIONS. Department of Public Works Jeff Hill, PE
ENGINEERED FOUNDATIONS Department of Public Works Jeff Hill, PE What is an engineered foundation. A Foundation Design Developed by a Trained Professional (Engineer) Types of Foundations (All of which can
SECTION 02400 - STORM DRAIN SYSTEM
SECTION 02400 - STORM DRAIN SYSTEM CONTENTS: Part 1 - General... 1 1.01 Work Included... 1 1.02 Related Requirements... 1 1.03 Reference Standards... 1 1.04 Quality Assurance... 1 1.05 Measurement And
G. Common Defects in Buildings - Leakage
F. Common Defects in Buildings - Structural 32. Recently, some concrete chips have fallen from the ceiling in my kitchen. There are rusty steel bars and the area in question measures about 300 x 400mm.
Proposed Minimum Subterranean Termite Treatment Standards
Proposed Minimum Subterranean Termite Treatment Standards Introduction This document is intended to serve as a model for states considering the adoption of standards for soil application of termiticides.
SANITARY SEWER SPECIFICATIONS
SANITARY SEWER SPECIFICATIONS OCTOBER 2003 HARVEST-MONROVIA WATER, SEWER, AND FIRE PROTECTION AUTHORITY SECTION 1.00 1.10 Purpose The purpose of this document is to assemble the sewer specifications, policies,
Texas Building Pros Foundation Repair Services
Foundation Repair Services Lets get things back on the level Life is not about the work you put into your love, It s about the Love you put into your work. -Mother Theresa Why Choose Texas Building Pros:
PC-Concrete Injectable Concrete Anchoring and Repair System
PC-Concrete Injectable Concrete Anchoring and Repair System DESCRIPTION: PC-Concrete is a two component (1:1 ratio), 100% solids, high modulus, structural epoxy paste. PC-Concrete is a solvent free, no
LAYING BLOCK AND BRICK
LAYING BLOCK AND BRICK Products highlighted in this section: SAKRETE Type N Mortar Mix SAKRETE Type S Mortar Mix Brick And Block Laying Basics The first step in building a brick or block wall is to construct
CONCRETE SEGMENTAL RETAINING WALL SYSTEM
CONCRETE SEGMENTAL RETAINING WALL SYSTEM PART 1: GENERAL SPECIFICATIONS 1.01 Work Included A. Work shall consist of furnishing and constructing a Rockwood Classic 8 with PCS unit segmental retaining wall
Hydrophobe VII., Lisbon
Hydrophobe VII., Lisbon The water repellent treatment of building materials in thermal baths Debrecen, Hungary The geothermal potential in EU János Major University of Debrecen, Faculty of Thermal baths
SEWER BACKUPS & BASEMENT FLOODING PREVENTATIVE SOLUTIONS FOR THE BUILDING OWNER
Village of Shorewood, Wisconsin SEWER BACKUPS & BASEMENT FLOODING PREVENTATIVE SOLUTIONS FOR THE BUILDING OWNER Prepared By: Thomas A. Zoulek, P.E., LEED A.P. Vice President Mid City Plumbing & Heating
C. Section 014510 TESTING LABORATORY SERVICE.
SECTION 014500 QUALITY CONTROL PART 1 GENERAL 1.01 RELATED REQUIREMENTS A. Drawings and General Provisions of Contract, including General and Special Conditions and other Division 1 Specification Sections,
SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION 623.10 CONCRETE BONDING COMPOUND.
SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION 623.10 CONCRETE BONDING COMPOUND. 623.10.1 Description. This work shall consist of preparing the surface,
Termites: How to Reduce Your Home's Risk of Infestation
Ohio State University Fact Sheet Entomology 1991 Kenny Road, Columbus, OH 43210-1000 Termites: How to Reduce Your Home's Risk of Infestation HYG-2092C-00 Susan C. Jones, Ph.D. Assistant Professor of Entomology
1. ASTM C 140 - Sampling and Testing Concrete Masonry Units 2. ASTM C 1372 Standard Specification for Dry-Cast Segmental Retaining Wall Units
SPECIFICATION FOR SEGMENTAL RETAINING WALL SYSTEMS PART 1: GENERAL 1.01 Description A. Work shall consist of furnishing materials, labor, equipment and supervision to install a segmental retaining wall
MASONRY RESTORATION Lime Putty Mortar Repointing Guide
1.0 Preparation for Lime Putty Mortar Pointing 1.1 Tools & Approach A. Grinding - When used in a controlled way, angle grinders with diamond-impregnated metal blades with a maximum 1/8-inch-thickness and
Safe & Sound Bridge Terminology
Safe & Sound Bridge Terminology Abutment A retaining wall supporting the ends of a bridge, and, in general, retaining or supporting the approach embankment. Approach The part of the bridge that carries
PERFORMANCE GUIDELINES
1. Foundation/Basement 17 PERFORMANCE GUIDELINES 1. FOUNDATION/BASEMENT 1.1 Efflorescence on concrete or masonry surfaces Efflorescence is the formation of a white crystalline or powdery deposit on the
2006 ICRI Baltimore Washington Chapter Outstanding Repair Project Award George Washington University Ross Hall Façade Restoration
2006 ICRI Baltimore Washington Chapter Outstanding Repair Project Award George Washington University Ross Hall Façade Restoration 2006 ICRI Baltimore Washington Chapter Outstanding Repair Project Award
CAUSES, EVALUATION AND REPAIR OF CRACKS IN CONCRETE
3.0 Causes and control of cracking: 3.1 Plastic Shrinkage Cracking: It occurs within 1 to 8 hours after placing, when subjected to a very rapid loss of moisture caused by a combination of factors, which
E ER TITAN PRODUCTS. Foundation Repair
E GIN E ER E D N EX CEL ENCE L Foundation Repair ENGINEERED EXCELLENCE Authorized Installer of Titan Products, Inc. Titan Products, Inc. 615.746.6876 2111 Boat Factory Rd., Pleasant View, TN www.titanproductsinc.com
Pro-Lift Steel Pile Foundation Repair
Pro-Lift Steel Pile Foundation Repair Pro-Lift Steel Pile Foundation Repair System Pro-lift steel piles are designed for the stresses of Texas soils. They can have multiple steel walls, depending on the
Soils, Foundations & Moisture Control
Soils, Foundations & Moisture Control Soil The top loose layer mineral and/or organic material on the surface of the Earth that serves as a natural medium for the growth of plants and support for the foundations