Cooling Solutions. for the IT environment



Similar documents
2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms

APC APPLICATION NOTE #112

The Different Types of Air Conditioning Equipment for IT Environments

Choosing Close-Coupled IT Cooling Solutions

Element D Services Heating, Ventilating, and Air Conditioning

APC APPLICATION NOTE #92

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity

Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009

Power and Cooling for Ultra-High Density Racks and Blade Servers

Improving Rack Cooling Performance Using Airflow Management Blanking Panels

- White Paper - Data Centre Cooling. Best Practice

In Row Cooling Options for High Density IT Applications

CRAC Precision climate control units for data centres

Cooling Audit for Identifying Potential Cooling Problems in Data Centers

Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED.

Blade Server & Data Room Cooling Specialists

Improving Rack Cooling Performance Using Airflow Management Blanking Panels

Data Centre Solutions... energy efficient by design. APC by Schneider Electric Elite Data Centre Partner. APC s leading Elite Data Centre Solutions

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

Rack Systems Solutions

Raised Floor Data Centers Prepared for the Future

MovinCool Office Pro Series. The Portable Spot Cooling Solution

Mechanical Rooftop Custom Capabilities

PX100 MBP with Configurable Distribution

IPSIP M series-m Modular Data Center

Strategies for Deploying Blade Servers in Existing Data Centers

How To Improve Energy Efficiency Through Raising Inlet Temperatures

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

Environmental Data Center Management and Monitoring

Glossary of Heating, Ventilation and Air Conditioning Terms

Defining Quality. Building Comfort. Precision. Air Conditioning

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Cabinets 101: Configuring A Network Or Server Cabinet

Unified Physical Infrastructure (UPI) Strategies for Thermal Management

Best Practices for Wire-free Environmental Monitoring in the Data Center

Unified Physical Infrastructure SM (UPI) Strategies for Smart Data Centers

Elements of Energy Efficiency in Data Centre Cooling Architecture

Blade Servers and Beyond: Adaptive Cooling for the Next Generation of IT Systems. A White Paper from the Experts in Business-Critical Continuity

Cabinet V800 V800 CABINETS

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

CoolTeg Plus Chilled Water (CW) version: AC-TCW

RPV - RP - RA air handling units

ECOCIAT. Domestic hot water heat recovery unit

Racks & Enclosures. Deliver. Design. Define. Three simple words that clearly describe how we approach a Data Center project.

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014

CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS

ADC-APC Integrated Cisco Data Center Solutions

Dealing with Thermal Issues in Data Center Universal Aisle Containment

Portable Energy Efficient Data Centre Solution

Data Center Technology: Physical Infrastructure

How To Power A Bladecenter H Servers

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

Nirvana. Cycling Refrigerated Dryers

How To Run A Data Center Efficiently

Improving Data Center Energy Efficiency Through Environmental Optimization

DATA CENTER SOLUTIONS

Data Center Rack Level Cooling Utilizing Water-Cooled, Passive Rear Door Heat Exchangers (RDHx) as a Cost Effective Alternative to CRAH Air Cooling

Smart-UPS On-Line 230 V

How and Why Mission- Critical Cooling Systems Differ From Common Air Conditioners

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

Galaxy VM. Three-phase power protection. schneider-electric.com

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: Uptime Racks:

For protection from laptops to high availability facilities - and everything in between - APC is a partner you can count on

Avoidable Mistakes that Compromise Cooling Performance in Data Centers and Network Rooms

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

The New Data Center Cooling Paradigm The Tiered Approach

Knürr DCL Modular Rack Cooling from 6 kw to 60 kw

IT White Paper MANAGING EXTREME HEAT: COOLING STRATEGIES FOR HIGH-DENSITY SYSTEMS

Humidification Strategies for Data Centers and Network Rooms

EHDC. Cooling system for Data Center and server cabinets.

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Managing Cooling Capacity & Redundancy In Data Centers Today

Bring the fresh in. Dedicated Outside Air Systems

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

york air-conditioning products Residential & VRF News 2015

How To Build A T7 Rack For Information Technology

AisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA North America Version 5 August 22, 2008 Page 1

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

Benefits of Cold Aisle Containment During Cooling Failure

Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server

Benefits of. Air Flow Management. Data Center

THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER

FOXAIR 60/50 ALL MODELS

Cooling Strategies for IT Wiring Closets and Small Rooms

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

How to Meet 24 by Forever Cooling Demands of your Data Center

Statement of Work. 3.0 Details of Service Pre Start-up Cooling Start-up Service. Installation Service. Table of Contents. 1.0 Executive Summary

Energy Management Solutions

Data Center Energy Profiler Questions Checklist

Chilled Water Precision Air Conditioner For Critical Application

Data Center Rack Systems Key to Business-Critical Continuity. A White Paper from the Experts in Business-Critical Continuity TM

Why Do I Need Precision Air Conditioning?

Transcription:

Cooling Solutions for the IT environment

APC has the complete cooling solutions line for your data center needs. We offer a range of products to meet all density levels for wiring closets, small, medium, and large data centers. Our highly efficient, scaleable solutions with active response controls offer predictable cooling for your needs today and in the future. Donna Williams Director, Product Line Management, Cooling Solutions Modular/High-Density Air Conditioning 4 InfraStruXure InRow RC InfraStruXure Cooling Distribution Unit InfraStruXure InRow RP InfraStruXure InRow SC Hot Aisle Containment System Rack Air Containment System Air Distribution/Fans 9 Wiring Closet Ventilation Unit Rack Air Removal Unit SX Rack Air Distribution Unit Rack Side Air Distribution Unit Room Air Conditioning 13 NetworkAIR FM NetworkAIR PA Heat Rejection 15 Chillers System-level solutions for data centers on demand InfraStruXure, APC s innovative methodology for designing, deploying and optimizing data centers, fully integrates power, cooling, security, and environmental management within a rack-optimized design. Using an open, building-block approach, InfraStruXure allows the selection of standardized components to create a solution through modular configurations. This standardization enables an easily scalable architecture designed to meet changing needs and future expansion. This award-winning, patent-pending approach increases availability, improves adaptability, speeds deployment, and lowers the total cost of ownership for IT environments from wiring closets to server rooms to data centers. The support structure of all highly available networks consists of power, cooling, racks and physical structure, security and fire protection, cabling, and the management and servicing of these elements. For more information about APC s Cooling Solutions, visit www.apc.com or call 1-888-289-6268

Ensuring the proper environment for IT systems is essential to maintaining high availability. Regardless of application, IT equipment produces heat that can be damaging to both uptime and the longevity of your investment. Designed to provide cool air distribution and heat removal in any IT environment at the rack, row, and room level, APC cooling solutions give you the maximum amount of cooling in the least amount of floor space. Scalable solutions, including air distribution/fans, portables, and precision cooling systems, are tailored to meet the unique cooling demands of your environment, from wiring closets and computer rooms to data centers of all sizes. 30 kw & above Heat Density (per rack) Server Room / Wiring Closet Solutions Product / Applications Data Center Solutions Product / Applications Rack Air Containment High Density Racks Best predictability 23 kw Hot Aisle Containment System High Density Zones Best capacity sharing Best predictability Best floor space utilization Improved redundancy and efficiency 10 kw InRow RC & CDU, RP Medium to high density modular and scalable 7 kw 4 kw InRow SC In-row air conditioning for server rooms and wiring closets NetworkAIR PA Portable, self-contained air conditioning Air Removal Unit Hot spot problem solver NetworkAIR FM Low density Very flexible 3 kw Wiring Closet Ventilation Unit Rapidly deployable wall and ceiling mount heat removal Air Distribution Unit Raised floor air distribution Side Air Distribution Unit Side to side air distribution For more information about APC s Cooling Solutions, visit www.apc.com or call 1-888-289-6268 3

Modular/High Density Air Conditioning InfraStruXure InRow RC In-row air conditioning for medium to large data centers including high density applications. Data center heat densities continue to increase, making it more difficult to provide adequate cooling. To ensure proper airflow paths the distance between the heat source and heat removal system must decrease. The in-row concept closely couples cooling with heat load, preventing exhaust air recirculation to sensitive IT equipment. The InfraStruXure InRow RC is a computer room air conditioning system designed for installation in the row to maximize sensible cooling and increase efficiency. The unit captures heat directly from the hot aisle and distributes cool air ensuring that equipment temperatures are constantly held to setpoint conditions. The energy-efficient design lowers total cost of ownership by monitoring IT equipment inlet temperatures to modulate capacity based on the demand for cooling. Fan speed is controlled based on the demand to reduce energy consumption during off-peak cooling periods. Heat rejection for the unit can be handled through an existing chilled water system or an APC-supplied chiller. The modular, scalable solution improves agility by enabling you to add cooling as demand increases, making the InRow RC ideal for small to large datacenters. Active response controls Monitor and actively adjust cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided. Predictable cooling Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture. Dual A-B power inputs Draws power from the UPS for power protection with dual feeds for redundancy. Top and bottom chilled water connections Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor. Total Cost of Ownership Variable speed fans Variable speed fans reduce energy consumption during off-peak cooling periods. In-Row architecture In-row architecture enables pay-as-you-grow deployment of cooling. Microprocessor controller Utilizes intelligent, proactive control and real-time capacity monitoring. The system is controlled by a master microprocessor providing high level control functionality and human interface via a four line, eighty character, alphanumeric display. Building management system integration Sends alarms and data points allowing you to manage critical building infrastructure from a single system. Infrastruxure manager compatible Enables centralized management via the APC InfraStruXure Manager. Cooling Option Capacity Airflow ACRC100 Chilled Water up to 30 kw 2900 CFM ACRC103 Nominal Input Voltage 100V,120V 200V Input Power 1100 Watts 1380 Watts Input Frequency Rack Height 50/60 Hz 42U Input Connections NEMA L5-20P IEC 309 16A 2P+E Control panel Maximum Height Maximum Width Maximum depth Multi-function LCD status and control console 78.39 in (1991.00 mm) 11.81 in (300.00 mm) 42.126 in (1070.00 mm) Net Weight 358 lbs. (162.73 kg) Color Black Units per Pallet 1 Regulatory Approvals cul Listed,FCC Part 15 Class A,ICES-003,Industry Canada,MEA,UL Listed,VCCI Agility 1 year (parts only) C-tick,CE,EN 55022 Class A,EN 55024,EN 60950,IEC 60950,IEC 61000-3-2,IEC 61000-3-3,MEA,VDE Modular design Provides scalable solutions to add cooling as demand increases. Serviceability Hot swappable fans Allow system to remain operational if a fan replacement is required. 4 For more information about APC s Cooling Solutions, visit www.apc.com or call 1-888-289-6268

InfraStruXure Cooling Distribution Unit Modular/High Density Air Conditioning Flexible chilled water distribution system for the InfraStruXure InRow RC. The Cooling Distribution Unit provides centralized cooling, balancing and distribution through jointless and flexible chilled water piping in the data center. The Cooling Distribution Unit and Chilled Water Whip system allows for quick deployment and enables customer infrastructure the flexibility to grow and change with minimal labor and installation costs. PEX-AL-PEX piping, used for chilled water piping between the CDU and InRow RC, allows the chilled water to be routed without the use of elbows or any intermediate joints from the CDU to each InRow RC. This application greatly improves the reliability of the system by dramatically reducing the chance of leakage. PEX-AL-PEX is a multi-layered composite tubing consisting of aluminum tubing sandwiched between inner and outer layers of cross-linked polyethylene, providing flexibility of the piping to be routed through the data center with the rigidity to stay in place. With smooth interior walls and the chemical properties of the material, PEX-AL-PEX is resistant to mineral buildup, corrosion, and the risk of pinholes. The multi-press fittings provide a reliable and leak resistant connection to both the CDU and InRow RC. The individual chilled water lines to the RC are both flexible and jointless, enabling customer infrastructure to be deployed quickly, added for future expansion, or rerouted with minimal time as demands change. Agility Flexible piping Flexible piping allows for quick deployment and start up. Jointless piping Jointless piping minimizes the risk of fluid leaks. Serviceability Coolant isolation Allows isolation of cooling circuits for servicing. ACFD12-CXX-T ACFD12-CXX-B Cooling Options Glycol, Chilled Water Capacity up to 12 InRow RC units Maximum Height 78.40 inches (1991 mm) Maximum Width 42.13 inches (1070 mm) Maximum depth 29.53 inches (750 mm) Net Weight 500 lbs. (227.27 kg) Color Black Units per Pallet 1 Regulatory Approvals cul Listed,MEA,UL Listed 1 year (parts only) For more information about APC s Cooling, visit www.apc.com or call 1-888-289-6268 5

Modular/High Density Air Conditioning InfraStruXure InRow RP In-row precision air conditioning for medium to large data centers including high density applications. InfraStruXure InRow RP is a high capacity precision air conditioning unit designed to maximize sensible cooling for high efficiency operation. The InRow RP product increases the capacity range for chilled water applications and includes an air cooled solution. Both the chilled water and air cooled products offer the ability to control humidity with canister humidifiers and electric reheat, enabling data center designs to leverage the InRow Architecture for both sensible cooling of the IT load in the row, and humidity control of the entire data center. The in-row concept closely couples cooling with the heat load, preventing exhaust air recirculation to sensitive IT equipment. The energy-efficient design lowers total cost of ownership by monitoring IT equipment inlet temperatures to modulate capacity based on the demand for cooling. Fan speed is controlled based on the demand to reduce energy consumption during off-peak cooling periods. The modular, scalable solution improves agility by enabling you to add cooling as demand increases, making the InRow RP ideal for small to large data centers. Active response controls Monitor and actively adjust cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided. Predictable cooling Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture. Rack inlet control Guarantees inlet temperature to IT equipment. Steam humidifier Humidity is managed through a self-contained steam canister humidifier for maximum efficiency and ease of maintenance. The pure-steam canister maintains consistent capacity output, and requires very little scheduled maintenance. Real-Time capacity monitoring Real-time display of current and available cooling. Electric reheat Prevents overcooling during dehumidification Total Cost of Ownership Variable speed fans Reduce energy consumption during off-peak cooling periods. In-Row architecture Enables pay-as-you-grow deployment of cooling. Agility Modular design Provides scalable solutions to add cooling as demand increases. Serviceability Field replaceable components Fans and electronics module can be readily replaced without uninstalling the unit. Microprocessor controller An 80-character LCD backlit alphanumeric display provides communication and alarm indication. ACRP100 ACRP101 ACRP102 ACRP500 ACRP501 ACRP502 Cooling Options R407C Chilled Water Capacity 10 37 kw up to 70 kw Airflow 4800 6950 Nominal Inout Voltage 200 240 3PH 460 480 3PH 380 415 3PH 200 240 3PH 460 480 3PH 380 415 3PH Input Power 13737W 11212W 13056W 3204W 2054W 2818W Input Frequency 50/60 60 50 50/60 60 50 Input Connections Warranty Hardwire 4-wire (3PH+G) 1 year parts only 6 For more information about APC s Cooling Solutions, visit www.apc.com or call 1-888-289-6268

Modular/High Density Air Conditioning InfraStruXure InRow SC Rapidly deployable, in-row air conditioning for server rooms and wiring closets. New technologies are increasing heat loads in today s server rooms and wiring closets, which often lack adequate cooling. The APC InfraStruXure InRow SC is a self-contained cooling solution that maximizes availability within small IT rooms. This energy-efficient unit lowers operating costs by using variable speed fans, capacity modulation, and an in-row form factor. The InRow SC s plug-andplay design allows for rapid installation without the need for running refrigerant lines or providing remote heat exchangers. The predictive failure notification and high head pressure protection features, along with hot-swappable fans, improve the availability of IT equipment. Agility Easy to install Self-contained design allows for fast installation without refrigerant lines or remote heat exchangers. Unit requires only power, condensate drain and an available return plenum to provide effective cooling. In-Row architecture Provides increased predictability of cooling performance. Modular design Provides scalable solutions to add cooling as demand increases. Real-Time capacity monitoring Displays current and available cooling. Microprocessor controller Displays an 80-character LCD backlit alphanumeric display that provides communication and alarm indication. Network manageable View the user interface with a browser. Gives quick access from anywhere on the network InfraStruXure Manager compatible Enables centralized management via the APC InfraStruXure Manager. Building management system integration Allows you to send alarms and data points to manage critical building infrastructure from a single system. Ducted condenser air Uses unconditioned air from plenum space to reject the heat rather than conditioned room air. Built-In condensate pump Factory installed pump collects and removes water from the air conditioner, ensuring continuous operation. High head pressure protection Ensures the InRow SC remains operational even when the condenser inlet air is restricted or very hot. Coil freeze protection Hot gas bypass prevents evaporator coil from freezing during light load conditions. Predictive failure notification Maximizes system availability by providing early warning of required fan or filter replacement. Automatic restart In the event of a power failure the InRow SC will resume operation. Cooling Option Capacity Compressor Type Air Discharge Patterns Intake Air Refrigerant Air Flow Nominal Input Voltage ACSC100 R410A up to 7 kw Rotary Horizontal Rear Return R410A 1200 CFM 200V, 208V, 230V ACSC101 Input Power 2940 Watts 2530 Watts Input Frequency 60 Hz +/- 3 Hz 50 Hz +/- 3 Hz Input Connections NEMA L6 20P IEC 309 16A 2P+E Control panel Maximum Height Maximum Width Maximum depth Net Weight Color Regulatory Approvals Multi-function LCD status and control console BSMI,EN 55022 Class A,FCC Part 15 Class A,ICES-003,UL Listed,VCCI,VDE, CCC 1991.00 mm 300.00 mm 1069.00 mm 165.91 kg Black 1 year repair or replace BSMI, EN 55022 Class A, FCC Part 15 Class A, ICES-003,UL Listed, VDE, VCCI C-tick, CE, CCC Serviceability Hot swappable fans Allow system to remain operational if a fan replacement is required. Washable filters Easy to maintain, cleanable, deep loading mesh filter removes particles from the return air stream. Total Cost of Ownership Rack inlet temperature control Reduces the risk of hot spots at the rack level. Variable speed fans Reduce energy consumption during off-peak cooling periods. Green refrigerant Environmentally friendly refrigerant that can offer LEED points. For more information about APC s Cooling, visit www.apc.com or call 1-888-289-6268 7

Modular/High Density Air Conditioning Hot Aisle Containment Hot aisle containment for high-density configurations. Mixing of hot and cold air streams in the data center lowers availability of IT equipment. Returning the warmest possible air to the computer room air conditioners increases the efficiency and capacity of the system. The hot aisle containment system ensures proper air distribution by completely separating supply and return air paths. The hot aisle is sealed off using doors and transparent ceiling tiles that extend the width of the hot aisle. Ceiling tiles are available for both 19 and 23 racks. Two-rack kits complete with ceiling tile and hardware are available for future expansion. Cable access brush strip Blocks air from escaping through holes surrounding cabling. Agility Ceiling tiles Close off the top of the hot aisle to prevent warm air from mixing with room air. One-way locking door Secures the hot aisle while allowing for quick exit in case of emergency. Scaleable densities Allow higher density cooling to be achieved by integrating the hot aisle containment system with in-row architecture. Modular design Modular design provides scalable solutions to add cooling as demand increases. Total Cost of Ownership Energy efficiency Increases cooling capacity of the associated air conditioners without driving up power consumption. Rack Air Containment Modular air containment system designed to maximize cooling predictability, capacity, and efficiency. Deployment of high density loads in IT environments can create areas of unpredictable cooling performance. APC s Rack Air Containment is a modular system designed to work in conjunction with APC NetShelter SX enclosures and InRow cooling units to provide maximum cooling predictability, capacity, and efficiency. By attaching to the rear of the NetShelter SX, air exhausted from IT equipment is forced to pass through the cooling unit where it is conditioned. This ensures that warm exhaust air does not find its way back to the air inlets of installed servers. N+1 and 2N configurations allow for maximum availability. Front containment can also be added to provide additional isolation and noise dampening. Adaptability Modular design Compatible with standard NetShelter SX racks, providing maximum system flexibility and scalability. Front containment Ensures cold supply air is not captured by neighboring equipment. Rear containment Ensures server exhaust air is returned to the InRow cooling units for maximum cooling predictability. Redundancy Systems can be configured to included an additional InRow cooling unit to provide N+1 or 2N redundancy. Integrated pressure sensors Pressure sensors in the InRow cooling units provide fan speed control for optimum system efficiency. Convenience Noise dampening Containment of both front and rear provides reduction of noise caused by installed equipment. Plexiglass door inserts Provides required air containment and a consistent look across the racks while allowing visibility to installed IT equipment. Easy to install Innovative design allows for fast, easy installation by almost anybody. 8 For more information about APC s Cooling Solutions, visit www.apc.com or call 1-888-289-6268

Air Distribution/Fans Wiring Closet Ventilation Unit Rapidly deployable wall and ceiling mount heat removal for wiring closets. Wiring closet heat loads are rising due to deployment of technologies such as VoIP and Power over Ethernet. The Wiring Closet Ventilation Unit is a rapidly deployable wall and ceiling mount heat removal system designed specifically for the wiring closet environment. By exhausting hot air from the closet to an adjacent space it allows conditioned air (entering through the Air Intake Grill) to cool the load. Dual fans increase availability while LED status indicators and dry contact outputs enhance the unit s manageability. Selectable fan speeds allow the user to choose between maximum performance and quiet operation. Fault-tolerant fan system In event of a fan failure the remaining fan automatically speeds up to compensate. Fans are N+1 redundant up to 300 CFM of airflow. Selectable speed fans Selectable fan speed (high/low) via toggle switch provides options for maximum performance or quiet operation. Adaptability Multiple mounting methods Flexible design allows for both drywall and ceiling mount installations. Easy to install Innovative design allows for fast, easy installation by almost anybody. Hardwire capable For installations where hard wiring is required or prefered. Architecturally neutral Unobstrusive design and coloring blends in with the surroundings. Predictive failure notification Maximizes system availability by providing early warning of required fan replacement. Dry contact output Provides remote notification of failures when used with APC environmental monitoring unit or system. LED status indicators Provide visual notification of fan failure. Cooling Capacity Options Air Flow Nominal Input Voltage Input Power ACF301 3 kw of heat removal 475.00 CFM 100 240V, 50/60 Hz 85 Watts Input Input Connections Hard Wire 3-wire, IEC-320 C14, NEMA 5-15P Maximum Height Maximum Width Maximum depth Color 12.80 inches (325 mm) 17.10 inches (434 mm) 7.00 inches (178 mm) White Regulatory Approvals cul Listed,CE,EN 55022 Class A,EN 55024, FCC Part 15 Class A,VCCI 2 years repair or replace For more information about APC s Cooling, visit www.apc.com or call 1-888-289-6268 9

Air Distribution/Fans Rack Air Removal Unit SX Performance heat removal for high-density equipment in NetShelter SX and VX enclosures. High-density equipment creates an environment where traditional air distribution methods are often not effective. Densely packed enclosures can cause IT equipment to overheat, resulting in downtime. The Rack Air Removal Unit SX captures exhaust heat, ducting it to the return air plenum and eliminating hot spots. Through automatic fan speed adjustment based on temperature or power consumption, the fans will self-adjust for optimal performance. With a unit-mounted LCD display users can view temperatures at the rack, monitor alarm conditions and adjust unit set points. The integrated network management card allows for remote monitoring and control of the Rack Air Removal Unit SX. This space-saving product mounts to the back of either the NetShelter SX or VX enclosure requiring zero U space. Network manageable View the user interface with a browser. Gives quick access from anywhere on the network InfraStruXure Manager compatible Enables centralized management via the APC InfraStruXure Manager. Temperature monitoring Allows up to 3 remote sensors to monitor rack inlet temperature. LCD display Accessible without opening the door for easy operation. Allows user to locally monitor and control the unit. Fault-tolerant fan system In event of a fan failure the remaining fans will speed up to compensate. Fans are N+1 redundant up to 1500 CFM of airflow. Dual A-B power inputs Draw power from the UPS for power protection with dual feeds for redundancy. Ducted Exhaust System Removes hot air from the data center to prevent recirculation and eliminate air mixing. Field replaceable components Fans and electronics module can be readily replaced without uninstalling the unit. Adaptability Adjustable mounting frame The frame can mount on Netshelter SX or VX enclosures and extends to accommodate 42U, 47U or 48U rack heights. Zero U Solution Mounts to the rear of the rack, leaving valuable rack space for other equipment. Total Cost of Ownership Easy to install Innovative design allows for fast, easy installation by almost anybody. Variable speed fans Reduce energy consumption during off-peak cooling periods. Increased capacity Higher rate of heat removal allows more equipment to be installed in each rack. Cooling Capacity Options ACF400 23 kw ACF402 Air Discharge Patterns Upflow,Ducted Upflow,Ducted Air Flow Nominal Input Voltage Input Power Input Frequency 2000 CFM 100V,120V,200V,208V,230V 1200 Watts 50/60 Hz Input Connections IEC-320 C14, NEMA 5 15P Control panel Maximum Height Multi-function LCD status and control console 1918.00 mm Maximum Width 597.00 mm 737.00 mm Maximum depth 254 mm Net Weight 67.27 KG 77.27 KG Color Regulatory Approvals Black cul Listed,CE,EN 55022 Class A,EN 55024,FCC Part 15 Class A,ICES-003,IEC 61000-3-2,IEC 61000 3 3,UL Listed,VDE,VCCI 2 years repair or replace 10 For more information about APC s Cooling Solutions, visit www.apc.com or call 1-888-289-6268

Air Distribution/Fans Rack Air Distribution Unit Air distribution for power dense enclosures and low pressure areas The Rack Air Distribution Unit is a 2U fan unit that works with an existing precision air conditioning system to deliver cool air to the equipment contained in a rack enclosure. The Rack Air Distribution Unit connects into the raised floor and pulls supply air directly into the enclosure. This prevents the conditioned air from mixing with warmer room air before reaching the equipment. The Rack Air Distribution Unit minimizes temperature differences between the top and bottom of the enclosure. It also prevents hot exhaust air from recirculating to the inlet of the enclosure. The product is recommended for rack enclosures with loads greater than 1.5kW and can provide airflow for loads up to 3.5kW. It is also ideal for enclosures in raised floor environments where underfloor air distribution is inadequate. : Dual fans Deliver air to equipment in the rack where floor tile velocity is inadequate for proper cooling. Raised floor duct Delivers cool, conditioned air directly from the raised floor to the inlet of the IT equipment. Agility Air filtration Removes dirt and other particulates from the intake air for cleaner supply air. Fan control switches Users can turn one or both fans on and off depending on the heat load. Mounting rails Adjustable depth allows the unit to fit APC's NetShelter enclosure or other 19" EIA-310-D enclosure. Fan guards A safety measure that provides protection from the fan opening by covering the inlet. Total Cost of Ownership Dual A-B power inputs Draw power from the UPS for power protection with dual feeds for redundancy. ACF001 ACF002 ACF003 Air Flow 503 CFM 420 CFM 503 CFM Amp Draw Nominal 2A 1A 2A Nominal Input Voltage 120V 208V, 230V 100V Input Power 240 Watts 230 Watts 200 Watts Input Frequency 60 Hz +/- 1Hz 50/60 Hz 50/60 Hz Rack Height Input Connections C-13 NEMA 5 15P Maximum Height 2U C-13 IEC-320 C14 89.00 mm C-13 NEMA 5 15P Maximum Width 422.00 mm 421.00 mm Maximum depth Net Weight Color Regulatory Approvals UL Recognized 737 mm 18.64 KG Black CE, UL Recognized 2 years repair or replace METI Denan, UL Recognized For more information about APC s Cooling, visit www.apc.com or call 1-888-289-6268 11

Air Distribution/Fans Rack Side Air Distribution Unit Air distribution for networking equipment with side to side airflow Housing equipment with side to side airflow creates many challenges for IT and facility managers, particularly in regards to cooling. Because most enclosures are designed for a front to back airflow pattern, it is difficult to maintain ideal operating temperatures on side to side airflow equipment. The Rack Side Air Distribution Unit allows for greater security and organization by allowing racks to be placed adjacent to one another without impeding airflow. The Rack Side Air Distribution Unit is a 2U rack mountable air distribution product for networking equipment or servers with side to side airflow. It pulls in conditioned air from the front of the rack and distributes it to the side air intake of the networking equipment. This extends equipment life by providing proper inlet temperatures. This product is recommended for one or more networking products that are stacked consecutively in a rack. Rack Side Air Distribution Units may be placed above and/or below the networking equipment. Airflow pattern is user configurable via an interchangeable air turning vane. ACF201BLK ACF202BLK Nominal Input Voltage 120V 208V, 230V Input Power 150 Watts Input Frequency 60Hz 50/60Hz Air Flow 260 CFM Amp Draw Nominal 2 A 1 A Net Weight 32 lbs (15kg) Max. Height 3.44 inches (87.4 mm) Max. Width 16.98 inches (431 mm) Max. Depth 26.34 inches (669 mm) Color Black Approvals UL Recognized CE Standard warranty 2 years repair or replace : Dual fans Deliver air to equipment in the rack where floor tile velocity is inadequate for proper cooling. Fan control switches Users can turn one or both fans on and off depending on the heat load. Agility Mounting rails Adjustable depth allows the unit to fit APC's NetShelter enclosure or other 19" EIA-310-D enclosure. Fan guard A safety measure that provides protection from the fan opening by covering the inlet. Total Cost of Ownership Dual A-B power inputs Draw power from the UPS for power protection with dual feeds for redundancy. Air turning vane Directs air up or down the side of the rack, supplying cool air to the inlet of side to side airflow equipment. LED status indicators Indicate the operating condition of the unit including power-on and alarm state. 12 For more information about APC s Cooling Solutions, visit www.apc.com or call 1-888-289-6268

Room Air Conditioning NetworkAIR FM Modular floor mount precision air conditioning for environmentally sensitive equipment areas The NetworkAIR FM utilizes leading edge precision air technologies. Modular construction, variable frequency drives, dedicated dehumidification, tandem scroll compressors, and front service access are all integrated into one high efficiency system. A scalable design enables customers to meet the changing needs of their environments. Tandem scroll compressors Quiet and efficient operation of scroll compressors, connected on a common circuit for staged capacity control (N/A chilled water systems). Direct drive motors Stress on bearings is nearly eliminated, increasing useful life. Allows integral fan/motor assembly to be factory balanced which lowers vibration and expedites startup. Eliminates the need for unreliable belts, pulleys and special bearings. Variable frequency drives Enable the fans to be soft started, saving energy during power up. Controlling the motor speed simplifies the adjustment for static pressure and gives the option of back-draft prevention. Steam humidifier Humidity is managed through a self-contained steam canister humidifier for maximum efficiency and ease of maintenance. The pure-steam canister maintains consistent capacity output, and requires very little scheduled maintenance. Serviceability Front service access The system has full service, front access for routine servicing of components. Front access also narrows the footprint of the system making it possible for units to be placed side by side. Protection Double-walled panels Separates insulation from the air stream, which prevents periodic maintenance of the insulation and reduces noise levels. Small particles of insulation can be picked up by the air stream if not isolated. Economy Dedicated dehumidification Boosts system efficiency by adding latent capacity without overcooling or increasing the requirement for reheat, resulting in up to 15% lower energy consumption (N/A chilled water systems). SCR electric reheat Modulates capacity to save energy. Exacting amounts of reheat loaded equally on all three phases. Programmable input/output contacts Allows device contacts to be connected to the air conditioner and mapped to customer outputs or system alarms. Microprocessor controller Provides proactive control and real-time monitoring via a four line, eighty character alphanumeric display. Network interface Provides management by connecting the device directly to the network with a dedicated IP address, avoiding the need for a proxy such as a server. Management is available via Web browser, Telnet or SSH. Notification features inform you of problems as they occur. Redundant group control Allows up to 4 groups of precision air conditioners to communicate with each other for redundancy, demand fighting prevention, mode assist, and global sharing of certain settings. FM-DX 60Hz FM-CW 60Hz FM40H-AGB-ESD FM40B-CFB-ESD Cooling Options Air, Water, Glycol, Economizer, Multicool Chilled Water Air Chilled Water Humidification Capacity 10 lbs/hr 10 lbs/hr Compressor Type / Refrigerant Tandem Scroll / R22 N/A Tandem Scroll / R407C N/A Input Frequency 60 Hz 50 Hz Nominal Input Voltage 208V 3PH, 480V 3PH, 600V 3PH 400V 3PH Air Discharge Patterns Downflow, Upflow Front Return, Upflow Rear Return Downflow Control Panel Microprocessor Controller Net Weight 2,360 lbs (1072.73 kg) 1,180 lbs (536 kg) 2,360 lbs (1072.73 kg) 1,180 lbs (536 kg) Max. Height 76.89 inches(1953.01 mm) Max. Width 70.87 inches (1800.1 mm) Max. Depth 35.00 inches (889.00 mm) Approvals CSA, MEA, UL Listed CE, Eurovent 1 year (parts only) optional extended warranties available. For more information about APC s Cooling, visit www.apc.com or call 1-888-289-6268 13

Room Air Conditioning NetworkAIR PA* Portable, self-contained air conditioning solutions for small rooms and data closets Inconsistent and high temperatures can lower the expected life of, and permanently damage your electronic equipment. IT refreshes and equipment relocation result in unpredictable and ever-changing environments. The NetworkAIR PA provides portable cooling for your sensitive electronic equipment to meet the environmental demands of small rooms and data closets. This self-contained solution does not require an external condenser, refrigerant piping, or building water source for operation. Heat is rejected to a drop ceiling or adjacent area via a flexible duct kit. The NetworkAIR PA can be installed quickly and inexpensively, without the need for building modifications. : Automatic restart Returns the unit to its last operating status in the event of a power failure, in order to protect the compressor and the environment. (Not available on the AP7003 unit). Ducting kit Allows hot air to be removed and distributed to a drop ceiling or hard-ducted return. This increases the efficiency of the computer room air conditioning system in both capacity and dehumidification. High head pressure protection Prevents compressor damage (not available on AP7003 unit). Agility Easy to install Self-contained, air cooled design allows for fast, easy installation. Replacement ceiling tile Fits into a standard drop ceiling to provide a connection point for the ducting kit. (Not available on the AP7003 unit). Casters Provide flexibility to move the unit to wherever cooling is required. ACPA4000 AP7003 Cooling Capacity 3.9kW 1.6kW Cooling Options Air Compressor Type Rotary Nominal Input Voltage 120V Input Power 1,610 Watts 692 Watts Input Frequency 60Hz Coolant R22 Air Flow 600 CFM 170 CFM Condensate Tank N/A 3.5 qt Condensate Pump 1.6 gal/hr N/A Approvals UL Listed 1 year repair or replace Network manageable Remotely monitor and control NetworkAIR PA4000 environmental information from anywhere on the network via a Web browser (not available on the AP7003 unit). LED status indicators Four (4) external status indicator LEDs represent: major alarm; minor alarm; check log (new alarm/warning has occurred); system on (evaporator blower is running). Not available on the AP7003 unit. On/off scheduling Allows the user to determine when the unit operates, saving energy costs. (Not available on the AP7003 unit). * available in North America only 14 For more information about APC s Cooling Solutions, visit www.apc.com or call 1-888-289-6268

Heat Rejection Air Cooled Modular Chillers* Air Cooled Chillers for air conditioning equipment in data centers, server rooms and wiring closets. APC air cooled chillers for air conditioning equipment in data centers are a new generation of leading-edge technology. These all-in-one integrated packages reduce time and cost of installation. : Microprocessor controller Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display. ModBus translator Optional feature allows integration with Building Management System. Total Cost of Ownership Variable speed fans Reduce energy consumption during off-peak cooling periods. Integrated hydronics package Includes all the necessary components to make one connection to the chilller without the need of external connections to auxiliary equipment such as pumps, increasing the speed of deployment. Scroll compressors Utilize few moving parts for increased reliability and life expectancy. Independent power feed Optional feed to the pumps allows for wiring to the UPS, thus ensuring chilled water availability during generator start-up when used with a storage tank. Dual redundant pumps Provide reliable chilled water flow sized for full capacity. Low ambient controls Enable chiller operation in temperatures down to -20 F. Convenience Optional storage tank Fits under chiller without increasing footprint. SKU Series ACCH050 ACCH084 ACCH120 ACCH167 ACCH200 ACCH220 Capacity 50kW 84KW 120KW 167KW 200KW 220KW UPSable pump (optional) Yes Yes Yes Yes N/A N/A Storage tank option ACTA1100 ACTA1101 ACTA1102 ACTA1102 N/A N/A Windbaffle option ACAC30001 ACAC30002 ACAC30003 ACAC30004 ACAC30005 ACAC30005 Voltages 208/3PH, 480/3PH 208/3PH, 480/3PH 208/3PH, 480/3PH 208/3PH, 480/3PH 208/3PH, 480/3PH 208/3PH, 480/3PH Height in inches* 52 52 52 52 90 90 Width in inches* 82 108 108 108 95 95 Depth in inches* 43 43 90 90 89 89 Weight in lbs* 1298 1819 3134 3603 4705 4911 1 year (parts only), optional extended warranties available * Weights and dimensions do not include storage tank or windbaffles * available in North America only For more information about APC s Cooling, visit www.apc.com or call 1-888-289-6268 15

Since 1981, APC has been a global leader in power availability solutions, setting the industry standard for quality, innovation, and support. From its corporate headquarters in West Kingston, Rhode Island, APC operates sales offices throughout the world and manufacturing facilities on four continents and distribution facilities on five continents. APC ships products to over 150 countries. Over 30 million satisfied customers worldwide depend on APC s Legendary Reliability. Propelled by real-world experience and a drive towards technological innovation, APC has the experience, scale, global presence, and stability to respond to emerging IT availability needs. As the recipient of hundreds of awards worldwide, APC is recognized for excellence in both its business and product performance. Every year since 1999, APC has been named to the Forbes Platinum 400 list of the Best Big Companies in America. For 11 years in a row, APC has received the Channel Champion award in the UPS category. Cooling Strategies for Ultra-high density racks and blade servers Choose the optimal service solution to increase your system availability. Receive your FREE APC white paper Cooling Strategies for Ultra-High Density Racks and Blade Servers. Visit us online at http://promo.apc.com and enter key code s369y. APC s quality system is certified by ISO 9002 standards For more information call: Tel: 800 800 4APC - US & Canada Tel: 401 789 0204 - World wide APC Corporate APC North America 132 Fairgrounds Road West Kingston, RI 02892 USA Call: 800 800 4APC Fax: 401 789 3710 APC Latin America 5301 Blue Lagoon Drive Suite #610 Miami, FL 33126 USA Call: 305 266 5005 Fax: 305 266 9695 APC Europe APC Ireland Ballybrit Business Park Galway, Ireland Call: +353 91 702000 Fax: +353 91 756909 APC Asia Pacific APC Australia Level 13 The Denison 65 Berry Street North Sydney, NSW 2060 Call: +61 2 9955 9366 Fax: +61 2 9955 2844 Visit: www.apc.com e-mail: apcinfo@apc.com Web Support: : support. apc.com 2007. All rights reserved. All APC trademarks are property of American Power Conversion. Other trademarks are property of their respective owners. Specifications are subject to change without notice. PART# 996-2854B