HPM-5 Performance Testing



Similar documents
Comparison of Vector Network Analyzer and TDA Systems IConnect Generated S-Parameters

R3765/67 CG Network Analyzer

Utilizing Time Domain (TDR) Test Methods For Maximizing Microwave Board Performance

Shielding Effectiveness Test Method. Harbour s LL, SB, and SS Coaxial Cables. Designs for Improved Shielding Effectiveness

Agilent De-embedding and Embedding S-Parameter Networks Using a Vector Network Analyzer. Application Note

AUTOMATIC NETWORK ANALYZER PROCEDURES FOR 5045 KLYSTRON CAVITIES * J.G. Judkins

PRODUCT SPECIFICATION

Engineering Sciences 151. Electromagnetic Communication Laboratory Assignment 3 Fall Term

Application Guide to RF Coaxial Connectors and Cables

Recommendations for TDR configuration for channel characterization by S-parameters. Pavel Zivny IEEE GCU Singapore, 2011/03 V1.

Successfully negotiating the PCI EXPRESS 2.0 Super Highway Towards Full Compliance

USB 3.0 INTERNAL CONNECTOR AND CABLE SPECIFICATION

Probes and Setup for Measuring Power-Plane Impedances with Vector Network Analyzer

High Speed Characterization Report

Solving Difficult Cable Measurements

HP 8970B Option 020. Service Manual Supplement

USB 3.1 Channel Loss Budgets

Sensor and Simulation Notes. Note 479. October A Dual-Polarity Impulse Radiating Antenna

2. The Vector Network Analyzer

Revision 1.10 April 7, 2015 Method of Implementation (MOI) for 100BASE-TX Ethernet Cable Tests Using Keysight E5071C ENA Option TDR

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

Vector Network Analyzer Techniques to Measure WR340 Waveguide Windows

ECE 435 INTRODUCTION TO THE MICROWAVE NETWORK ANALYZER


Agilent Improved Method for Characterizing and Modeling Gigabit Flex-Circuit Based Interconnects. White Paper

DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD OF INSERTION LOSS MEASUREMENT

EMC Basics. Speaker : Alain Lafuente. Alain.lafuente@we-online.com

Applying Error Correction to Network Analyzer Measurements. Application Note Table of Contents. Page

How To Sell A Talan

HIGH RELIABILITY POWER SUPPLY TESTING

Impedance 50 (75 connectors via adapters)

Report Of. Shielding Effectiveness Test For. SafeSleeve Radiation Shielding Technology. Test Date(s): June 07 June 09, 2015

Managing Connector and Cable Assembly Performance for USB SuperSpeed

High-Definition Multimedia Interface (HDMI) Source/Sink Impedance Compliance Test Test Solution Overview Using the E5071C ENA Option TDR

FREQUENCY RESPONSE OF AN AUDIO AMPLIFIER

LOW LOSS CABLE PAG. 1

Common Mode Choke Filtering Improves CMRR in Ethernet Transformer Applications. Application Note. June 2011

Agilent PN RF Component Measurements: Amplifier Measurements Using the Agilent 8753 Network Analyzer. Product Note

IF MATRIX SWITCH FOR THE 40 METER RADIO TELESCOPE

PCb Cable mount twinax. ConneCtorS

Ultra640 SCSI Measured Data from Cables & Backplanes

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

Specification. SGP.18c. Part No. SGP C.02. Product Name. GPS SMT Patch Antenna. Feature

TETRIS High Impedance Active Probe. Features:

RClamp0522PA RClamp0524PA

Network Analyzer Operation

TETRIS 1000 / High Impedance Active Probe Order-No: Features:

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

Twinax Intra Pair Skew Comparison Report Various Lengths and Competitors Tested

A Comparison of Measurement Uncertainty in Vector Network Analyzers and Time Domain Reflectometers. White Paper

USB2.0 Technical Manual

MICRO SFP+ CONNECTOR & CABLE ASSEMBLY

Agilent Test Solutions for Multiport and Balanced Devices

Eye Doctor II Advanced Signal Integrity Tools

Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics

Mini-DINs. Low PIM Cable Assemblies and Coaxial Adapters. Always Thinking

ULTIMATE SNAP-N-SEAL

Power Sensor/Meter with USB Interface Connect Directly to a PC

HyperSound System (HSS) Demo and Evaluation Systems Set-Up and Operation Guide

Card electrical characteristic, Parallelism & Reliability. Jung Keun Park Willtechnology

Kit Watt Audio Amplifier

Cable Impedance and Structural Return Loss Measurement Methodologies

Current Probes. User Manual

The Application of Vector Network Analyzers in Balanced Transmission Line Signal Integrity Measurements

Agilent PN Extending Vector Signal Analysis to 26.5 GHz with 20 MHz Information Bandwidth

Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview

Jitter in PCIe application on embedded boards with PLL Zero delay Clock buffer

Agilent Electronic Calibration (ECal) Modules for Vector Network Analyzers

Agilent Time Domain Analysis Using a Network Analyzer

TECHNOTES. TD1001: The best RF protector for applications not requiring dc on the coax.

Transmission of High-Speed Serial Signals Over Common Cable Media

The Design & Test of Broadband Launches up to 50 GHz on Thin & Thick Substrates

Networking 101 (Networking Basics) Presentation to UCHUG - 1/03/07 G. Skalka

Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk

Super-Flex Traveling Cable Type ETT/300V

Coaxial Cable Products Guide. Connectivity for Business-Critical Continuity

TCR Token Ring Copper Repeater Module

PCI Express Transmitter Electrical Validation and Compliance Testing with Agilent Infiniium Oscilloscopes

Measuring of optical output and attenuation

Agilent AN In-Fixture Measurements Using Vector Network Analyzers

Annex 113A Description of cable clamp and test setup. (informative) 113A.1 Overview

Cable Analysis and Fault Detection using the Bode 100

Table Of Contents. Introduction. New Products. Index. Adapters, Cables and Connectors. Amplifiers. Attenuators. Detectors

STF THRU STF203-33

Cond-IS RF Conducted Immunity System

Coaxial Cable Solutions Guide

Times Microwave Systems Hermetically Sealed Assemblies

Spectrum Analyzer Two models available: OGR-24 (24 GHz) and OGR-8 (8 GHz)

Cable 101. A Broadband Telecommunications Primer for Non-technical Personnel

Cabling Specifications

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Data Receivers. Digital Data Receivers

Spectrum Analyzer Two models available: OGR-24 (24 GHz) and OGR-8 (8 GHz)

Why is Passive Intermodulation Important?

Encoders. the incremental encoders format such as relective optical technology, transmissive optical technology

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

RX-AM4SF Receiver. Pin-out. Connections

Digital Systems Ribbon Cables I CMPE 650. Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip.

Performance of LVDS With Different Cables

DVT913 TV CHANNEL CONVERTER

Transcription:

HPM-5 Performance Testing Test 234 JF Sawdy 7/3/02 Samples: Double-ended 2mm cable assemblies: 3, 6 and 8 meters end-to-end, using Meritec s 700219-01 28 awg twinax cable and Meritec s HPM-5 connectors wired GSSGSSG. Test Equipment and Software: Tektronix CSA-803 Digital Sampling Oscilloscope with SD-24 TDR /Sampling Heads Microwave Logic Gigabert-660TX 700MHz Eye Pattern Generator (used to verify 622MHz eye diagram extractions) Hewlett Packard HP-8753C, 300 KHz to 6 GHz Network Analyzer Anzac Differential Baluns, 2Mhz to 2GHz TDA Systems' IConnect TM Version 2.0.3 interconnect and lossy cable characterization software 2mm 5+2 AMP male connectors 0.085 dia. semirigid 50 ohm coax probes Meritec s Test Board #1159-00102 Flexible 50 ohm coax interface cables 888-MERITEC (888-637-4832) / (440)-354-3148 FAX: (440) 354-0509 WWW.MERITEC.COM INFO@MERITEC.COM

Differential Eye Diagrams at 622Mhz, 1.2 Ghz and 2.4 GHz extracted from TDR measurements using IConnect TM software 3 Meter Assembly (unequalized) 622MHz 1.2GHz 2.4GHz

Differential Eye Diagrams at 622Mhz, 1.2 Ghz and 2.4 GHz extracted from TDR measurements using IConnect TM software 6 Meter Assembly (unequalized) 10 Meter Assembly (unequalized) 622MHz 622MHz 1.2GHz 1.2GHz 2.4GHz 2.4GHz

Attenuation through cable (S21) Measured from 500MHz to 3GHz Smoothing set at 20% (500Mhz) Used differential baluns rated to maximum frequency of 2 GHz (results indicate baluns are valid to 3GHz) Fixture and connectors were de-embedded; results reflect cable attenuation Summary of results: Attenuation (decibels) Frequency 3 meters 6 meters 10 meters 500 MHz -2.65-5.89-10.17 1GHz -3.74-8.36-14.36 2GHz -5.52-12.04-20.77 3Ghz -6.96-15.18-26.02 28 awg Attenuation 0-5 -10-15 -20 3m 6m 10m -25-30 0 1000 2000 3000 4000 Frequency (MHz)

Attenuation through cable (S21) (continued) Network Analyzer Traces CH1 S 21 log MAG 3 db/ REF 0 db 1_:-2.6519 db 500.000 000 MHz Cor Smo SMOOTHING APERTURE 500 MHz 20 % SPAN 2_:-3.7414 db 1 GHz 3_:-5.5237 db 2 GHz 4_:-6.9565 db 3 GHz 1 2 3 4 START 500.000 000 MHz STOP 3 000.000 000 MHz Measured on 3 meter cable

Attenuation through cable (S21) (continued) Network Analyzer Traces CH1 S 21 log MAG 3 db/ REF 0 db 1_:-5.8851 db 500.000 000 MHz Cor Smo SMOOTHING APERTURE 500 MHz 20 % SPAN 2_:-8.3557 db 1 GHz 3_:-12.038 db 2 GHz 4_:-15.176 db 3 GHz 1 2 3 4 START 500.000 000 MHz STOP 3 000.000 000 MHz Measured on 6 meter cable

Attenuation through cable (S21) (continued) Network Analyzer Traces CH1 S 21 log MAG 3 db/ REF 0 db 1_:-10.168 db 500.000 000 MHz Cor Smo SMOOTHING APERTURE 500 MHz 20 % SPAN 2_:-14.357 db 1 GHz 3_:-20.77 db 2 GHz 4_:-26.016 db 3 GHz 1 2 3 START 500.000 000 MHz STOP 3 000.000 000 MHz 4 Measured on 10 meter cable

Risetime Degradation Risetime measured at 20-80% Fixture 71 psec (black trace) 5 inch assy 88 psec (red trace) 3 meter assy 550 psec (purple) 6 meter assy 1400 psec (black) 10 meter assy 3400 psec (green) Risetime degradation = Measured risetime minus fixture risetime 5 inch assy 17 psec 3 meter assy 480 psec 6 meter assy 1330 psec 10 meter assy 3330 psec 3500 3000 2500 2000 1500 1000 500 0 0 2 4 6 8 10 Length (meters)

Skew Traces show skew as measured on 3 meter assembly Near end - purple and green Far end - red and black 3 meter assembly 84 psec 6 meter assembly 110 psec 10 meter assembly 220 psec Average 21.8 psec/meter (6.7 psec/foot)

Electrical Length Traces show electrical length as measured on 3 meter assembly Near end - purple and green Far end - red and black 3 meter assembly 13.296 nsec 6 meter assembly 26.518 nsec 10 meter assembly 44.320 nsec Average 4.43 nsec/meter (1.36 nsec/foot)

Differential Impedance at Connector Differential impedance through header (including via) and connector left to right (risetime filtered to 200 psec) Minimum 96 ohms Maximum 109.6 ohms

Appendix A Compare TDA Extracted Eyes to Actual Eye Measurements at 622MHz (Measured results include effects of test pc board shown below, whereas extracted results do not include test PC board) Test PC Board 3 Meter Assembly Extracted Measured

Appendix A (continued) 6 Meter Assembly Measured Extracted 10 Meter Assembly Extracted Measured