CHILLED WATER DATA ROOM UNITS



Similar documents
Element D Services Heating, Ventilating, and Air Conditioning

Critical Infrastructure for the World s Leading Data Centers

Indirect Evaporative Cooling (IDEC) Unit for Data Centers

Mechanical Rooftop Custom Capabilities

Installation Manual CLIFC Fan & Coil Variable Speed

Chilled Water Precision Air Conditioner For Critical Application

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

CE6500 Energy Recovery Ventilator

ROOF TOP MOUNTED Air Handler Specification

How To Save Energy On A Power Supply

Liebert CW kW Chilled Water Cooled Precision Air Conditioning For Data Centers

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Dehumidification Frequently Asked Questions

Commercial Gas Furnace Upflow

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

SECTION HEAT PUMPS

A. Section includes air conditioning units, controls and control panels.

Glossary of Heating, Ventilation and Air Conditioning Terms

PLUG and PLAY VRV Connection

The prevailing force in the field. AIR CONDITIONING SOLUTIONS FOR THE PULP AND PAPER INDUSTRY

Bring the fresh in. Dedicated Outside Air Systems

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

Fans and Air Handling Units. Will Rea and Paul Pilutti February 16 th, 2011

Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO

Johnson Air-Rotation Systems

Cooling Capacity CFM in. w.c. (125 Pa)

Innovent LASER Packaged Fresh Air Conditioning Units

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

A. Air-Conditioning and Refrigeration Institute: 1. ARI Commercial and Industrial Air Filter Equipment.

Liebert DS Thermal Management Unit

5-60kW. EasiCool Range. - 60kW. Typical Applications

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

ARMSTRONG AIR HEAT PUMPS

CRAC Precision climate control units for data centres

CoolTeg Plus Chilled Water (CW) version: AC-TCW

Defining Quality. Building Comfort. Heating and Cooling Coils

Cooking at the Speed of light!

Local Dealer:

SPECIFICATION DIVISION 23 SECTION DESCRIPTION DIVISION 23 HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION BLOWER COIL UNITS

SECTION MORTUARY REFRIGERATORS

Cased/Uncased Coils For Gas And Oil Furnaces

Fan Dia. Motor Amps Connections Approx. 115 V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V Inlet Suction Drain Ship. Wt. Lbs.

GTS Gas-to-Steam Humidification System

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

SECTION AIR CONDITIONING UNIT

HIGH EFFICIENCY RTU. HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

MAC-120HE-01 Air-Cooled Chiller

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

RPV - RP - RA air handling units

CB29M Bulletin # February 1996

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

Cooling Audit for Identifying Potential Cooling Problems in Data Centers

6 MECHANICAL HVAC SYSTEMS

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

SPACE COOLERS. P.O. Box 956 Paoli, PA (800) FAX (610) The leader in packaged Space Cooling.

SECTION A. Horsepower: Do not increase or decrease fan motor horsepower without written approval from Engineer.

ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA

Chilled Water Fan Coil Unit. Model:HFCA Size 03~14

Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED.

Low Profile Unit Cooler

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

1.2 Refrigerant Equipment. General

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

HUMIDIFICATION DESIGN CHECKLIST: GETTING IT RIGHT THE FIRST TIME.

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

How and Why Mission- Critical Cooling Systems Differ From Common Air Conditioners

Modular Access Floor for Data Center. From Rack to Row to Room to Building

Cooling/Heat Pump Convertible Air Handlers

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

3/29/2012 INTRODUCTION HVAC BASICS

INDOOR COILS. RCFM- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

GTS. New! Plus: PR0DUCT CATALOG. Vapor-logic 4 controller with: and LonTalk. New models GTS-500 and GTS-700. Gas-to-Steam Humidification System

Basics of HVAC Cleaning

KONRAD. Hybrid Fancoil Series

60-150kW. For more information on Airedale visit SmartCool kW. > SmartCool.

DESCRIPTION FEATURES HORIZONTAL DUCT HD. ISO 9001 Certified Quality Management System

SASO XXXX:2016. (Including the modifications approved in Saudi Council Board No. XXX/2016) LARGE CAPACITY AIR CONDITIONERS

Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: Uptime Racks:

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_001_ Products that provide lasting solutions.

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Statement of Work. 3.0 Details of Service Pre Start-up Cooling Start-up Service. Installation Service. Table of Contents. 1.0 Executive Summary

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

A GUIDE TO SELECTING YOUR INDUSTRIAL OVEN

Blade Server & Data Room Cooling Specialists

In Row Cooling Options for High Density IT Applications

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application and Design. Ratings. Features and Control Options.

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

CITYPLEX TOWERS BOILER INSTALLATION ORU RFP-1138

Single Package Vertical Air Conditioners. Vert-I-Pak

Transcription:

Critical Infrastructure for the World s Leading Data Centers CHILLED WATER DATA ROOM UNITS Downflow Net Sensible Cooling 79 220kW Upflow Net Sensible Cooling 66 206kW A Nortek Company

DATA CENTER COOLING EXPERTISE Data Center managers have unique needs. CES Group listens to your needs and responds with innovative, engineered solutions to meet the specific requirements of your data center applications. Our people have extraordinary experience in the exacting demands of mission critical facilities to provide you with the best and most economical solution for the entire life cycle of your data center. Your Benefits Maximized use of Free Cooling designs incorporating direct and indirect evaporative cooling (IDEC) concepts in addition to water and airside economizer systems to minimize or eliminate the energy consumed for mechanical cooling. Flexibility to design a system with the lowest possible footprint to maximize available space for computing and/or data storage equipment. Close match of operating capacity requirements to avoid the inefficiencies and added electrical demands of over-sized equipment, while often allowing for expansion within the existing footprint. N+1 redundancy at the lowest possible connected horsepower and footprint. Robust equipment with low maintenance requirements and easy access to components to avoid downtime. The manufacturing capacity of 12 facilities in North America and the U.K. to meet your fast-track project requirements. For more information about CES Group data center solutions, contact us at datacenterinfo@ces-group.com. 3 CES Group

DATA ROOM UNITS High Efficiency Cooling for High Density Loads High efficiency data room units (DRU) are designed for high density load areas where a large cooling duty is required from a compact footprint, and to provide the reliability and redundancy required for the critical application of data center cooling. The standard range for our downflow and upflow CW units is 79 220 kw and 66 206 kw respectively. Custom size units are available from 85 525 kw providing the flexibility to reduce the number of units, electrical and piping requirements as well as indoor footprint devoted to computer room cooling. All configurations have energy reduction features as well as heating or humidification options. Where required, the units can be supplied with electrode boiler humidifiers providing high efficiency stepless output of sterile steam and electric heaters are available if reheat is required. The DRU Range has been designed around a modular frame and panel design providing maximum unit strength plus all-around access where applicable. However, all maintenance and service has been designed for front access only where site restrictions dictate. The units are designed for either downflow or upflow service. FANWALL TECHNOLOGY provides even, efficient air supply and inherent redundancy. Alternatively, the units can be fitted with speed controllable, electronically commutated (EC) fan/motor assemblies. Multiple fan/motor assemblies and variable frequency drives (VFD) share system load to increase efficiency and reduce system impact in the unlikely event of a key component failure. Modular component assemblies are designed for easy and quick component maintenance and replacement. Unit Features / Controller The DRU is fitted with a fully programmable direct digital controller (DDC) or industrial PLC controller complete with display/user interface. The controller monitors the temperature and relative humidity and activates cooling humidification or dehumidification to provide precise and efficient conditioning of the supply air. Additionally, the DDC controller monitors the in-built safety devices of the unit, which constantly monitor the healthy state of key components. In the unlikely event of a component malfunction, the item is automatically isolated to enable the plant to continue running, and an alarm signal will be generated. Where required, multiple units can be networked together to provide group or run/standby control. Units can be monitored locally or remotely, and if required, an enhanced web-enabled controller can be supplied, providing password-restricted access from a suitable Internet access point. Model DRU 8 Shown Control Features Fully programmable Data logging Standalone or group control BMS interface Remote monitoring Energy saving control strategies Monitor and Alarm Points Temperature Relative humidity Airflow Filter condition Drain pan water detection Humidifier status Heater status Fire shutdown VFD relay alarms Smoke detection DDC Controller External Panel Mount HMI CES Group 4

INDUSTRIAL-GRADE Data Room Unit (DRU) Optimized chilled water coil with low air and waterside pressure drop Longer filter life and reduced pressure drop due to larger filter area More efficient direct-drive fans with higher static pressure capability than EC fans Improved uniformity of air flow over coils and in velocity from plenum Humidifier and chilled water coil Fan section (backward inclined air foil) with non-obtrusive air flow measuring device Touch screen controller Control valves and piping Internally mounted electrical control panel 5 CES Group

DRU COMPONENTS Cabinet The DRU unit is constructed of galvanized sheet steel panels, insulated with 1-inch thick thermal/acoustical duct liner with enhanced surface with sealed transverse edges. The DRU cabinet is constructed using a steel pentapost frame and panel design. Insulated hinged access doors and screwed panels provide all around access, but all service and maintenance items are designed to be performed from the front of the unit. The front access doors are locked using key operated quarter turn latches to seal the doors against a continuous closed cell Poron urethane foam gasket. All frames and panels shall be coated with a Dry Powder-Baked Polyester coating similar to Tiger #7035, Drylac Series 49 which is both lead and cadmium free. FANWALL System Direct driven, Class 3, backward inclined centrifugal fans with air foil blades mounted in the DRU fan base section are constructed of steel pentapost frame and panel, designed to be situated under the raised access floor. The fans are arranged to discharge horizontally to maximize mechanical and static efficiency. The fans are rated by AMCA and balanced to exacting industry standards for specific use in our FANWALL TECHNOLOGY application. Each fan and inlet cone is fitted with a nonobtrusive airflow measuring device and coupled with a transmitter to send real time volume signal to the DDC for control and transmittal of data to the BMS. The signal results in a digital readout in CFM on the touch screen HMI. Standard motors are AC type, in standard NEMA frame sizes, and TEAO design. Each motor shall employ the use of an Aegis shaft grounding ring. Cooling Coils Downflow units use dual cooling coils arranged in an A formation. Upflow units use a single coil in a slab configuration. The casing are constructed of minimum 16 gauge galvanized steel. Fins are aluminum plate ripple type. Tubes are copper and are mechanically bonded to aluminum fins. Drain pans are 304 stainless steel with solid welded seams. All coils are tested and rated in accordance with the Air-Conditioning, Heating and Refrigeration Institute (AHRI) Standard 410 and certified in accordance with the AHRI certification program. Control Valve Control valves are two or three way, cast iron or brass depending on size and application. Actuators are proportional type with an operating voltage of 24v. Control Panel Each unit ships complete with an independent or integral control panel. The control panel houses a main input fused disconnect with individual fused disconnect, DDC controller or programmable logic controller (PLC), and human mechanical interface device (HMI). The controller and HMI are factory mounted and installed for user connections and setup. It has options available for BMS interface via Modbus, LonWorks and BACnet. It can monitor all status points in the system necessary for maintaining room conditions such as humidity, temperature, raised floor differential pressure or duct static pressure; and airflow with optional inputs available for customer connections and monitoring. CES Group 6

DOWNFLOW AND UPFLOW MODELS Downflow Cooling Units Filter Section Filter Section Coil Section Coil Section Fan Section Fan Section Model DRU 8 (66 W x 100 H x 47.5 D) Models DRU 10, 12 and 14 (96 W x 100 H x 47.5 D) Upflow Cooling Units Fan Section Filter Section Coil Section 99 W 77 H 47.5 D Filter Section PerfectPleat 2 and 4 optional prefilters offer the efficiency and low initial resistance that you expect and require. Both the Standard and HC (High Capacity) models are rated MERV 7 and MERV 8 (ULTRA made with Intersept antimicrobial). Standard 4 PerfectPleat has 9 pleats per foot (PPF); HC has 11 PPF. Filter section is optional. Coil Section Custom heating and cooling water coils are designed and constructed for maximum efficiency in demanding applications. We offer a full range of sizes to meet specific commercial and industrial uses where high performance is necessary. Fan Section: FANWALL TECHNOLOGY Designed specifically for to achieve 7% to 9% higher efficiency than other fans in their size range. AMCA certified performance. Permanent Magnet Motor The FANWALL Permanent Magnet (PM) motor is a brushless permanent magnet motor which has proven to be 7% to 15% more efficient when compared to NEMA Premium efficiency induction motors. 7 CES Group

TECHNICAL SPECIFICATIONS DOWNFLOW MODEL CW-DRU-8 CW-DRU-10 CW-DRU-12 CW-DRU-14 Cooling Capacity (TOTAL) kw 96.2 113.5 139.5 178.1 170.1 225.3 182.1 242.4 Cooling Capacity (SENSIBLE) kw 79.2 102.6 115.5 161.7 141.8 202.8 153.1 219.8 Air Flow CFM/m³/h 10,000/ 16,990 10,000/ 16,990 Return Air Temperature F/ C 75 /24 86 /30 75 /24 86 /30 75 /24 86 /30 75 /24 86 /30 Return Air Humidity %RH 45% 30% 45% 30% 45% 30% 45% 30% 16,000/ 27,184 16,000/ 27,184 20,000/ 33,980 # of Fans per Unit 4 4 Fan Type - Class 3 Backward Incline Centrifugal Direct Drive Airfoil Total BHP @ Design HP 2.8 6.04 8.15 10.2 Operational Motor RPM RPM 1151 1552 1430 1544 Total Static Pressure @ Design In.H 2 O/kPa 1.25/0.31 1.65/0.41 1.80/0.45 2.0/0.5 External Total Static Pressure In.H 2 O/kPa 0.2/0.05 Fan Absorbed Power @ Design kw 2.00 4.50 6.08 7.54 CHW Entering Temperature F/ C 43 F / 6 C CHW CHW Flow GPM/m³/h 65.6 / 14.9 78.5 / 17.8 98.1 / 22.3 124.2 / 28.2 120 / 27.2 157.5 / 35.8 129.2 /29.3 170 / 38.6 Coil Rows 6 Coil Face Area Ft 2 /m 2 11.3 / 1.05 17 / 1.58 21 / 1.95 21 / 1.95 CHW Pressure Drop (total) PSI/kPa 7.26 / 50.0 7.9 / 54.4 11.2 / 77.2 8.7 / 59.75 7.74 / 53.4 8.46 / 58.3 8.9 / 61.4 14.62 / 100.8 CHW Connection size/valve size Pipe/Valve 2.0" / 2.0" 2.5" / 2.0" 3.0" / 2.5" 3.0" / 2.5" 3.0" / 2.5" Filter Type - PerfectPleat MERV 7 or 8 Dimensions (Inc. Fan Base & Filter Box with 2" Filters) Inches 100T 88W 47.5D 118T 88W 47.5D 118T 100W 47.5D Dimensions (Inc. Fan Base & Filter Box with 4" Filters) Inches 102T 88W 47.5D 120T 88W 47.5D 120T 100W 47.5D Dimensions (Inc. Fan Base & Filter Box with 51 mm Filters) mm 2540T 2236W 1207D 2997T 2235W 1207D 2997T 2540W 1207D Dimensions (Inc. Fan Base & Filter Box with 102 mm Filters) mm 2591T 2236W 1207D 3048T 2235W 1207D 3048T 2540W 1207D Coil Section Weight lbs./kg 1000/454 1300/590 1600/726 1600/726 Fan Section Weight lbs./kg 1450/658 1550/703 1700/771 1700/771 Total Weight lbs./kg 2450/1112 2850/1293 3300/1497 3300/1497 20,000/ 33,980 22,000/ 33,378 22,000/ 33,378 UPFLOW MODEL CW-DRU-8 CW-DRU-10 CW-DRU-12 CW-DRU-14 Cooling Capacity (TOTAL) kw 72.0 90.0 107.6 147.9 139.8 189.8 154.5 209.5 Cooling Capacity (SENSIBLE) kw 66.1 90.0 101.2 147.9 129.0 187.2 142.4 206.5 Air Flow CFM/m³/h 10,200/17,330 10,200/17,330 16,000/27,184 16,000/27,184 20,000/33,980 20,000/33,980 22000/33378 22000/33378 Return Air Temperature F/ C 75 /24 86 /30 75 /24 86 /30 75 /24 86 /30 75 /24 86 /30 Return Air Humidity %RH 45% 30% 45% 30% 45% 30% 45% 30% # of Fans per Unit 4 Fan Type - Class 3 Backward Incline Centrifugal Direct Drive Airfoil Total BHP @ Design HP 2.8 5 5.84 6.0 Operational Motor RPM RPM 1621 1891 1446 1174 Total Static Pressure @ Design In.H 2 O/kPa 1.2 / 0.3 External Total Static Pressure In.H 2 O/kPa 0.2 / 0.05 Fan Absorbed Power @ Design kw 2.10 3.70 4.40 4.5 CHW Entering Temperature F/ C 43 F / 6 C CHW. CHW Flow GPM/m³/h 50.4 / 11.5 62.7 / 14.2 75.7 / 17.2 103 / 23.4 98 / 22.3 132 / 30.0 108.1 / 24.6 145.5 / 33.0 Coil Rows 4 Coil Face Area Ft 2 /m 2 20.1 / 1.87 32.0 / 2.3 40.0 / 3.7 44.1 / 4.1 CHW Pressure Drop (total) PSI/kPa 9.4 / 64.8 10.5 / 72.7 7.5 / 51.5 12.5 / 86.6 11.75 / 81.0 11.2 / 76.9 13.6 / 93.7 12.5 / 86.4 CHW Connection Size / Valve Size Pipe/Valve 2.0" / 1.5" 2.5" / 2.0" 2.5" / 2.0" 3.0" / 2.5" 2.5" / 2.0" 3.0 / 2.5 Filter Type - PerfectPleat MERV 7 or 8 Dimensions (inc. Fan Base & Filter Box with 2 in. Filters Inches 75T 100W 33D 92T 112W 36D 100T 134W 40D 100T 144W 40D Dimensions (inc. Fan Base & Filter Box with 51 mm Filters) mm 1905T 2540W 839D 2337T 2845W 915D 2540T 3404W 1016D 2540T 3658W 1016D Total Weight lbs./kg 2900/1315 3650 / 1655 4150 / 1882 4700 / 2131 Note for both models: Project-specific fan and coil selections are available based on customer-specific conditions upon request. CES Group 8

R CES Group 13200 Pioneer Trail, Suite 150 Eden Prairie, Minnesota 55347-4125 USA datacenterinfo@ces-group.com Since CES Group, LLC has a policy of continuous product improvement, we reserve the right to change product specifications without notice. CES Group furnishes equipment pursuant to its then current Terms and Conditions of Sales and Limited Warranty, copies of which can be found under the Terms and Conditions and Warranty links at www.ces-group.com. A Nortek Company The following are trademarks and registered brand names of CES Group: Eaton-Williams, FANWALL, FANWALL TECHNOLOGY, Governair, Huntair, Mammoth, Temtrol, Venmar CES, Ventrol. LONWORKS is a trademark of Echelon Corporation. Modbus is a trademark of Schneider Electric. CES Group is a leader in innovative custom and engineered HVAC solutions for commercial, industrial and critical environments through our brands Eaton-Williams, Governair, Huntair, Mammoth, Temtrol, Venmar CES and Ventrol. CES Group, LLC is a subsidiary of Nortek, Inc., a global diversified company whose many market leading brands deliver broad capabilities and a wide array of innovative, technology-driven products and solutions for lifestyle improvements at home and at work. www.ces-group.com datacenterinfo@ces-group.com 2014 CES Group, LLC CESG-DC-SB-4B January 2015