FloVENT. Optimizing Data Center Cooling by Simulation. Mechanical Analysis



Similar documents
Airflow Simulation Solves Data Centre Cooling Problem

Fundamentals of CFD and Data Center Cooling Amir Radmehr, Ph.D. Innovative Research, Inc.

11 Top Tips for Energy-Efficient Data Center Design and Operation

Introducing Computational Fluid Dynamics Virtual Facility 6SigmaDC

The New Data Center Cooling Paradigm The Tiered Approach

Introducing the. Virtual Facility

High Density Data Centers Fraught with Peril. Richard A. Greco, Principal EYP Mission Critical Facilities, Inc.

Data centers have been cooled for many years by delivering

Thinking Outside the Box Server Design for Data Center Optimization

AEGIS DATA CENTER SERVICES POWER AND COOLING ANALYSIS SERVICE SUMMARY

Data Centre Energy Efficiency Operating for Optimisation Robert M Pe / Sept. 20, 2012 National Energy Efficiency Conference Singapore

Managing Cooling Capacity & Redundancy In Data Centers Today

Elements of Energy Efficiency in Data Centre Cooling Architecture

Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009

Using Simulation to Improve Data Center Efficiency

A Comparative Study of Various High Density Data Center Cooling Technologies. A Thesis Presented. Kwok Wu. The Graduate School

Benefits of. Air Flow Management. Data Center

Increasing Energ y Efficiency In Data Centers

CFD-Based Operational Thermal Efficiency Improvement of a Production Data Center

Airflow and Cooling Performance of Data Centers: Two Performance Metrics

GREEN FIELD DATA CENTER DESIGN WATER COOLING FOR MAXIMUM EFFICIENCY. Shlomo Novotny, Vice President and Chief Technology Officer, Vette Corp.

Managing Data Centre Heat Issues

Dealing with Thermal Issues in Data Center Universal Aisle Containment

Air, Fluid Flow, and Thermal Simulation of Data Centers with Autodesk Revit 2013 and Autodesk BIM 360

Analysis of the UNH Data Center Using CFD Modeling

Verizon SMARTS Data Center Design Phase 1 Conceptual Study Report Ms. Leah Zabarenko Verizon Business 2606A Carsins Run Road Aberdeen, MD 21001

Data center TCO; a comparison of high-density and low-density spaces

Airflow Uniformity through Perforated Tiles in a Raised-Floor Data Center

How to Meet 24 by Forever Cooling Demands of your Data Center

Using CFD for optimal thermal management and cooling design in data centers

The Benefits of Supply Air Temperature Control in the Data Centre

Control Strategies for Plenum Optimization in Raised Floor Data Centers

Hot Air Isolation Cools High-Density Data Centers By: Ian Seaton, Technology Marketing Manager, Chatsworth Products, Inc.

HP Data Center Services

- White Paper - Data Centre Cooling. Best Practice

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings

Energy Performance Optimization of Server Room HVAC System

How Row-based Data Center Cooling Works

W H I T E P A P E R. Computational Fluid Dynamics Modeling for Operational Data Centers

Specialty Environment Design Mission Critical Facilities

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions

Prediction Is Better Than Cure CFD Simulation For Data Center Operation.

Unified Physical Infrastructure SM (UPI) Strategies for Smart Data Centers

Optimizing Network Performance through PASSIVE AIR FLOW MANAGEMENT IN THE DATA CENTER

How To Run A Data Center Efficiently

Data Center 2020: Delivering high density in the Data Center; efficiently and reliably

Statement Of Work. Data Center Power and Cooling Assessment. Service. Professional Services. Table of Contents. 1.0 Executive Summary

Energy and Cost Analysis of Rittal Corporation Liquid Cooled Package

Data center upgrade proposal. (phase one)

Data Center Airflow Management Retrofit

Effect of Rack Server Population on Temperatures in Data Centers

Investigation into the energy consumption of a data center with a thermosyphon heat exchanger

Optimum Climate Control For Datacenter - Case Study. T. Prabu March 17 th 2009

IT White Paper MANAGING EXTREME HEAT: COOLING STRATEGIES FOR HIGH-DENSITY SYSTEMS

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

Energy Management Services

Data Center Equipment Power Trends

Reducing Room-Level Bypass Airflow Creates Opportunities to Improve Cooling Capacity and Operating Costs

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Rittal Liquid Cooling Series

Data center lifecycle and energy efficiency

Data Center Cooling & Air Flow Management. Arnold Murphy, CDCEP, CDCAP March 3, 2015

EXPERIMENTAL CHARACTERIZATION OF TRANSIENT TEMPERATURE EVOLUTION IN A DATA CENTER FACILITY

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions

RAISED-FLOOR DATA CENTER: PERFORATED TILE FLOW RATES FOR VARIOUS TILE LAYOUTS

How To Improve Energy Efficiency Through Raising Inlet Temperatures

Unified Physical Infrastructure (UPI) Strategies for Thermal Management

Computational Fluid Dynamics (CFD) Modeling Service

Unique Airflow Visualization Techniques for the Design and Validation of Above-Plenum Data Center CFD Models

Modeling Rack and Server Heat Capacity in a Physics Based Dynamic CFD Model of Data Centers. Sami Alkharabsheh, Bahgat Sammakia 10/28/2013

Data Center Technology: Physical Infrastructure

Cooling Audit for Identifying Potential Cooling Problems in Data Centers

Cost Model for Planning, Development and Operation of a Data Center

What to Consider When Designing Next-Generation Data Centers

Server Room Thermal Assessment

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Cooling a hot issue? MINKELS COLD CORRIDOR TM SOLUTION

HIGHLY EFFICIENT COOLING FOR YOUR DATA CENTRE

Data Center Power Consumption

BRUNS-PAK Presents MARK S. EVANKO, Principal

EXAMPLE OF A DATA CENTRE BUILD

Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED.

Energy Efficient Thermal Management of Data Centers

Reducing Data Center Energy Consumption

Transcription:

FloVENT Optimizing Data Center Cooling by Simulation Mechanical Analysis

Why Perform Airflow/Thermal Simulation in Data Centers? Why Choose FloVENT for Airflow Simulation in Data Centers? Providing adequate cooling is a major challenge for modern data center designers and operators, due to the escalating power densities associated with blade servers and other highspeed computing and switching equipment. Individual server rack heat loads now commonly exceed 10kW, and may reach over 30kW. According to a recent study [1], power consumption in US data centers doubled between 2000 and 2005, reaching in 2005 a figure approximately equal to the power consumed by all color televisions in the. Power consumption in data centers is expected to grow by a further 40% by 2010. Energy costs for power and cooling in data centers are now greater than the cost of the IT equipment itself, when amortized over a three-year period [2]. Since 1988, Mentor Graphics Mechanical Analysis Division has played a pioneering role in simulation of airflow and thermal comfort in all kinds of buildings using Computational Fluid Dynamics (CFD) techniques. As a result, FloVENT has become the most widely used, most validated, most dependable, and fastest CFD software for this type of application. You may choose to employ Mentor Graphics as a consultant, and/or license the FloVENT software for in-house use. Either way, we will help you minimize operating costs and downtime by visualizing and optimizing airflow, temperature distribution and cooling system performance. The FloVENT simulation software from Mentor Graphics creates a virtual data center with detailed 3D visualization of airflow and temperature at every point throughout the room. Armed with this vital information, you can quickly and easily: Minimize cooling power requirements and energy costs Optimize data center cooling effectiveness Ensure that temperatures are within specifications at all rack inlets and throughout the room Eliminate hot spots thus avoiding potential equipment failures and downtime Simulate transient effects (e.g. temperature build-up following CRAC failure) [1] Estimating total power consumption by servers in the US and the world, Jonathan G. Koomey, Ph.D, Staff Scientist, Lawrence Berkeley National Laboratory and Consulting Professor, Stanford University, Final report, February 15, 2007 [2] In the data center, power and cooling costs more than the IT equipment it supports, Christian L. Belady, P.E., Hewlett- Packard, Electronics Cooling Magazine, Volume 13, Number 1, February 2007 FloVENT is designed specifically for modeling heating and cooling applications so it is both easier to use and more powerful than other CFD codes when evaluating data center cooling. Mentor Graphics, Mechanical Analysis also has a team of support engineers that provide excellent support because they have a very good understanding of data center cooling issues. Ben Steinberg, Senior Engineer, American Power Conversion (APC) Ventilation and temperature distribution within a Data Center

Validation Columns Since 1988, FloVENT has been applied and validated in a wide variety of data center cooling applications by companies such as APC, BSRIA, BT, Emerson, HP, and IBM. In addition, FloVENT is widely used and extensively validated by building designers, engineering design consultants, and building owner/ operators for many different applications involving buildings of all types and sizes. This widespread use drives out software bugs and ensures robust simulation software that you can rely on. With Mentor Graphics and FloVENT, you can be sure that Simulation = Reality! The following technical papers are just a small selection from the huge range of papers demonstrating that the world s leading companies rely on FloVENT for data center cooling simulations. Validation Papers The following is a partial list of technical papers that have validated the use of FloVENT for data center cooling or similar applications. Visit our website for a full list. Cooling Solutions for IT, BSRIA Guidance Document Nigel Pavey, Foreman Roberts William Booth, BSRIA Stuart Hall, Flomerics Ltd Experimental-Numerical Comparison for a High-Density Data Center: Hot Spot Heat Fluxes in Excess of 500 W/ft² Saurabh K. Shrivastava, American Power Conversion Corporation Madhusudan Iyengar, IBM Systems & Technology Group Bahgat G. Sammakia, Dept. of Mechanical Engineering Roger Schmidt, IBM Systems & Technology Group 2455 James W. VanGilder, American Power Conversion Corporation Airflow Uniformity Through Perforated Tiles in a Raised-Floor Data Center James W. VanGilder, American Power Conversion Corporation Roger R. Schmidt, IBM Corporation Dimensionless Parameters for Energy-Effecient Data Center Design Ratnesh K. Sharma and Cullen E. Bash, Hewlett-Packard Laboratories 1. Room and Structure From design drawings, CAD or site survey 2 Ventilation Air handling device specifications from libraries based on manufacturers data Room Height Air Handling Device Room Length Return Cable Cutouts Supply Glazing - if any Void Height Floor Grilles Obstructions in Void e.g. Cable Trays A Non-Trial-and-Error CFD-Based Method For Balancing Airflow Through Floor Tiles in Raised-Floor Data Centers Jim VanGilder, Flomerics Raised Floor Computer Data Center: Effect on Rack Inlet Temperatures of Chilled Air Exiting both the Hot and Cold Aisles Roger Schmidt, Ethan Cruz, IBM Corporation Thermal Trends and Inflections Influencing the IT Roadmap David S. De Lorenzo, Intel Labs Thermal Considerations in Cooling Large Scale High Compute Density Data Centers Chandrakant D. Patel, Ratnesh Sharma, Cullen E. Bash and Abdlmonem Beitelmal, Hewlett-Packard Laboratories The Performance of Displacement Cooling Systems in Telecom Applications Ari Kemppainen, Ericsson R&D, Sweden CFD Modeling of High Compute Density Data Centers to Assure System Inlet Air Specifications Chandrakant D. Patel, Cullen E. Bash and Christian Belady, Hewlett- Packard Laboratories Lennart Stahl and Danny Sullivan, Emerson Energy Systems 3. Equipment Details and specifications of equipment housed in cabinets from data center configuration management system and manufacturers data 4 Simulation Results Information about: - Temperatures - Pressures - Air flow paths and velocities Cabinets Obstructions e.g. PDUs A Fresh Approach to Cooling Network Equipment Peter Kiff, BT Networks and Systems

FloVENT in Data Center Design and Operation Data center cooling simulation using FloVENT contributes to both: New-build designs to evaluate design cooling performance, identify and remedy cooling problems or likely hot spots ahead of build; optimize layout and cooling to minimize power consumption; investigate possible cooling system failures and system redundancy; and Ongoing operation and change management to assess and monitor intended and ongoing operational changes in equipment layout, cooling system, space utilization, etc, whilst minimizing cooling energy costs. Contact us today! Visit www.mentor.com/mechanical Email or call us direct at any of our worldwide offices listed on the back of this brochure. Of these the second is assuming increasing importance, as data center layout changes and equipment upgrades occur more and more frequently. Clearly the operation of present-day data centers involves a multiplicity of issues in addition to cooling asset lifecycle management, power infrastructure, network mapping, capacity planning, change management, and many more. FloVENT can be used alongside whatever data center management system is being used to address these, so as to provide a complementary thermal audit of cooling performance. This enables the operator to assess the potentially critical impact on cooling of the continual operational changes inevitable in present-day data centers. You may choose to employ Mentor Graphics as a consultant, and/or license the FloVENT software for in-house use. Either way, we will help you minimize operating costs and downtime by visualizing and optimizing airflow, temperature distribution and cooling system performance for all your data center projects. The benefits of undertaking CFD analysis are truly realized by Mentor Graphics Mechanical Analysis Division, their visual representations of temperatures and airflows have been the key on several of our projects. We provide a computational test bed to evaluate airflow and thermal behaviour of current and future data center designs, and operational changes. Armed with this vital information, you can quickly and easily: Minimize cooling power requirements and energy costs Optimize data center cooling effectiveness Ensure that temperatures are within specifications at all rack inlets and throughout the room Eliminate hot spots thus avoiding potential equipment failures and downtime Derek Morgan, Technical Director, WSP Group Plc

Mentor Graphics Corporate Headquarters 8005 S.W. Boeckman Rd. Wilsonville, OR 97070 Tel: +1 (503) 685-7000 Fax: +1 (503) 685-1204 Mechanical Analysis Division Offices UK 81 Bridge Road Hampton Court Surrey KT8 9HH United Kingdom Tel: + 44 (0)20 8487 3000 Fax: +44 (0)20 8487 3001 France Immeuble Le Pasteur 13/15 rue Jeanne Braconnier 92360 Meudon La Forêt France Tel: +33 (0)1 40 94 74 74 Fax: +33 (0)1 46 01 91 75 China Rm. 2902 Jin Mao Tower 88 Century Blvd, Pudong New Area Shanghai China 200121 Tel: +86 21 6101 6300 Fax: +86 21 5047 1378 Canway Building Room 1512, No.66 Nan Li Shi Lu Beijing China 100045 Tel: +86 10 680 80 320 Fax: +8610 680 80 319 Raiffeisenstr 16 D-70794 Filderstadt Tel: +49 711 77915-0 Fax: +49 711 77915-15 Hanauer Landstraße 188 60314 Frankfurt am Main Tel: +49 (0) 69 130 253 0 Fax: +49 (0) 69 130 253 53 Italy Palazzo F1 Milanofiori 20090 Assago MI Italy Tel: +39 02 5750 6502 Fax: +39 02 5779 2904 Sweden Kista Science Tower 164 51 Kista Sweden Tel. +46 8 632 95 00 Fax +46 8 632 00 13 India Salarpuria Touchstone Survey # 15/1A & 14 Kadubeesanahalli, Varthur Hobli Sarjapur Ring Road Bangalore, 560 087 India Tel: +91 80 3051 4000 Fax: +91 80 3051 4004 Japan Gotenyama Garden 7-35, Kita-shinagawa 4-chome Shinagawa-ku, Tokyo 140-0001, Japan Tel: +81-3-6866-7894 Fax: +81-3-5488-3031 Singapore 238A Thomson Road #23-07 Novena Square Tower A Singapore 307684 Tel: +65 6779 0075 Fax: +65 6779 1111 300 Nickerson Road, Suite 200 Marlborough MA 01752 Tel: +1 (508) 480 0881 Fax: +1 (508) 480 0882 5000 Plaza on the Lake, Suite 310 Austin TX 78746 Tel: +1 (512) 425 3000 Fax : +1 (512) 345 8094 880 Ridder Park Drive San Jose CA 95131 Tel: +1 (408) 436 1500 Fax: +1 (408) 487 7001 Mechanical Analysis Please visit our website at: www.mentor.com/mechanical Copyright 2009 Mentor Graphics Corp Mentor Graphics is a registered trademark of Mentor Graphics Corporation. All other trademarks mentioned in this document are trademarks of their respective owners