Measuring Biased Inductors with the GenRad Digibridge



Similar documents
Application Note. So You Need to Measure Some Inductors?

RLC Resonant Circuits

Understanding Power Impedance Supply for Optimum Decoupling

Lecture 24. Inductance and Switching Power Supplies (how your solar charger voltage converter works)

SERIES-PARALLEL DC CIRCUITS

EE301 Lesson 14 Reading: , , and

Model 1756 Test Lead Kit

An Overview of Practical Capacitance Bridge Functioning. by Paul Moses

Circuits with inductors and alternating currents. Chapter 20 #45, 46, 47, 49

Measuring Insulation Resistance of Capacitors

Reading: HH Sections , (pgs , )

Diodes have an arrow showing the direction of the flow.

CURRENT ELECTRICITY INTRODUCTION TO RESISTANCE, CAPACITANCE AND INDUCTANCE

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

= V peak 2 = 0.707V peak

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

Slide 1 / 26. Inductance by Bryan Pflueger

LR Phono Preamps. Pete Millett ETF.13.

Impedance Matching and Matching Networks. Valentin Todorow, December, 2009

ES250: Electrical Science. HW7: Energy Storage Elements

A Simple Current-Sense Technique Eliminating a Sense Resistor

WINDING RESISTANCE TESTING

Keywords: input noise, output noise, step down converters, buck converters, MAX1653EVKit

Inductors in AC Circuits

Physics 6C, Summer 2006 Homework 2 Solutions

Last time : energy storage elements capacitor.

Frequency Response of Filters

Common Base BJT Amplifier Common Collector BJT Amplifier

Analog Signal Conditioning

Induced voltages and Inductance Faraday s Law

Sophomore Physics Laboratory (PH005/105)

Common Emitter BJT Amplifier Design Current Mirror Design

Op amp DC error characteristics and the effect on high-precision applications

BSNL TTA Question Paper-Instruments and Measurement Specialization 2007

ε: Voltage output of Signal Generator (also called the Source voltage or Applied

Measurement of Capacitance

UT202A Operating Manual. Contents

Voltech DC1000. Precision DC Bias Current Source

Line Reactors and AC Drives

Solution Derivations for Capa #11

Operational Amplifier - IC 741

DRAFT. University of Pennsylvania Moore School of Electrical Engineering ESE319 Electronic Circuits - Modeling and Measurement Techniques

EET272 Worksheet Week 9

Unit/Standard Number. High School Graduation Years 2010, 2011 and 2012

Application Note AN:005. FPA Printed Circuit Board Layout Guidelines. Introduction Contents. The Importance of Board Layout

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS

Equipment: Power Supply, DAI, Variable resistance (8311), Variable inductance (8321)

DIGITAL-TO-ANALOGUE AND ANALOGUE-TO-DIGITAL CONVERSION

Basic Op Amp Circuits

ENEE 307 Electronic Circuit Design Laboratory Spring A. Iliadis Electrical Engineering Department University of Maryland College Park MD 20742

3053 Electrical Safety Training Program Course Outline

Model UT33A: OPERATING MANUAL Table of Contents (1)

W03 Analysis of DC Circuits. Yrd. Doç. Dr. Aytaç Gören

LOXONE 12 Channel Amplifier

Three phase circuits

Grounding Demystified

Lecture Notes: ECS 203 Basic Electrical Engineering Semester 1/2010. Dr.Prapun Suksompong 1 June 16, 2010

ADM1TE 5/30A DIN rail single phase two wire energy meter

Properties of electrical signals

unit : mm With heat sink (see Pd Ta characteristics)

Impedance Matching. Using transformers Using matching networks

Designing Stable Compensation Networks for Single Phase Voltage Mode Buck Regulators

Current Probes. User Manual

Electronics. Discrete assembly of an operational amplifier as a transistor circuit. LD Physics Leaflets P

INTRODUCTION. We are living in an age of Information Technology. Electronics is at the very foundation of the

Current Loop Application Note 1495

Voltage/current converter opamp circuits

Fundamentals of Signature Analysis

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

Electronics for Analog Signal Processing - II Prof. K. Radhakrishna Rao Department of Electrical Engineering Indian Institute of Technology Madras

Guidance for upgrading to GB (IEC : 2005, MOD)

Series and Parallel Circuits

Introduction. Harmonics and IEEE 519 Page 1 of 19

Evaluating AC Current Sensor Options for Power Delivery Systems

High Voltage Power Supplies for Analytical Instrumentation

GenTech Practice Questions

Model UT33B/C/D: OPERATING MANUAL Table of Contents (1)

Making Accurate Voltage Noise and Current Noise Measurements on Operational Amplifiers Down to 0.1Hz

Power measurement in balanced 3 phase circuits and power factor improvement. 1 Power in Single Phase Circuits. Experiment no 1

Application Note AN- 1095


Transistor Amplifiers

AC Direct Off-Line Power Supplies

Laboratory 4: Feedback and Compensation

RigExpert AA-30 Antenna Analyzer (0.1 to 30 MHz) AA-54 Antenna Analyzer (0.1 to 54 MHz) User s manual

Measuring Impedance and Frequency Response of Guitar Pickups

User Manual of Grid Tie Inverter with Limiter

LOW COST MOTOR PROTECTION FILTERS FOR PWM DRIVE APPLICATIONS STOPS MOTOR DAMAGE

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Printed-Circuit-Board Layout for Improved Electromagnetic Compatibility

CAUTION OPC-LM1-ID. Option Card for Frequency Divider. Fuji Electric FA Components & Systems Co., Ltd. Instruction Manual

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Non-contact surface charge/voltage measurements Fieldmeter and voltmeter methods

Chapter 11. Inductors ISU EE. C.Y. Lee

Residual Current Circuit Breaker

S-Parameters and Related Quantities Sam Wetterlin 10/20/09

S-Band Low Noise Amplifier Using the ATF Application Note G004

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

LM2576R. 3.0A, 52kHz, Step-Down Switching Regulator FEATURES. Applications DESCRIPTION TO-220 PKG TO-220V PKG TO-263 PKG ORDERING INFORMATION

Precision Diode Rectifiers

Transcription:

534 Main Street, Westbury NY 11590 www.ietlabs.com sales@ietlabs.com P: 5163345959, 8008998438 pplication Note Measuring Biased Inductors with the GenRad Digibridge This note is intended for those who have the need to make measurements on DCbiased inductors with the GenRad Digibridge. The object is to make these measurements accurate and safe. ll safety precautions should be used, including those suggested below. WRNING Inductors carrying current may contain lethal energy. Dangerous voltages are generated if connections are broken while the current is flowing. lways set all power sources to zero output before making or breaking connections. Limit supply voltages to 60V or less. Use redundant safety measures to greatly reduce the shock hazard to the operator and avoid damage to the measuring instrumentation. What is so Dangerous about Inductors? The voltage across an inductor is proportional to its inductance and the rateofchange of the current through it: E = L di/dt. If the current could be instantly switched off, the voltage would, in theory, become infinite. This does not happen in practice because the high voltage develops an arc across the switch as the contact is broken, keeping di/dt from becoming infinite. The voltage can, however, get very high. One might say that an inductor doesn't like to have its current changed and will develop a very high voltage in an effort to keep it flowing. If a person breaks the contact without the proper protection, the inductor induces a high voltage, forcing the current through him. The current flows from arm to arm, through the heart, and can easily be lethal. This hazard is all the more dangerous because it is unexpected there were no high voltages present before he broke the connections. person doesn't have to be across the broken connection to receive a dangerous shock, for the current may flow through ground. Therefore, breaking the circuit with one hand is not necessarily safe and the common safety precaution of one hand in the pocket may not work. Moreover, even if someone else at some distance away remotely performs the switching of the circuit, the person touching the inductor could still receive a lethal shock. disconnection might also be the result of a component or wiring failure that could happen at anytime. Figure 1 illustrates the breaking of the contact across the inductor.

Inductor Circuit Figure 1: Breaking the contact across an inductor The energy of an inductor is equal to 1/2 LI 2 and the danger increases as the energy increases. Safety standards do not cover the shock hazard from inductors, so that no value of energy can be considered safe. Even low energy levels, which may not in themselves be dangerous, can cause an involuntary physical reaction that can cause dangerous accidents. One should always assume the worse could happen and use utmost caution. One should use redundant safety measures, because any single protective device could fail and any safety procedure could be forgotten or even ignored. Suggested Safety Precautions To avoid shock hazard, we recommend all the following equipment and procedures: (Not to exclude those precautions the user already has in place) 1. Instruct the operator of the possible dangers. 2. Enclose the inductor in an insulated box with an interlock switch so that the current cannot flow when the box is open (See Figure 2). 3. Use redundant switching (See Figure 2). 4. Use some method of connecting the inductor that keeps the operator from directly touching the conducting connections. 5. Have some means of indicating that the current is indeed zero and instruct the operator not to touch anything in the box if the current is not zero. 6. Make sure the floor and work surface are dry and nonconductive. 7. Inspect and check the test setup regularly to make sure that the safety mechanisms function properly.

Inductor Measurement Setup measurement system should look something like that sketched in Figure 2. Indicates current Insulated wires Digibridge Power Supply Enclose connections Enclosed test fixture contains and bias circuit Figure 2: Example Inductor Test Setup switch should be activated when the box cover is closed. One way to do this is to use a pushbutton switch that is depressed by a protrusion from the cover. ll connections into the box should be well insulated and the connections to the power supply and the Digibridge should be enclosed and secured. The powersupply meter should be set to indicate current. The box should contain the inductor to be tested and all other inductors and other components of the bias circuit. void the high induced voltage by shorting the inductors carrying current with a switch rather than leaving them open (Figure 3). However, this method has a disadvantage: the ammeter will indicate high current whether the switch is open or closed and thus cannot be used as an additional safety indication. Feed Inductor Figure 3: Use a switch to short inductors n alternative method is to open the circuit, but use a rectifier to carry the transient discharge current (Figure 4). This should be a power rectifier with a current rating higher than the bias current used. Paralleling two rectifiers would give added safety in case of failure. Figure 4: Use a rectifier to pass transient current

Bias Method The suggested circuit (Figure 5) combines both methods, using a doublethrow switch and rectifiers. small 1000pF capacitor is added to avoid highspeed transients. Doublethrow switch Bias Method Figure 5: Recommended switching circuit The recommended method for supplying DC bias current to inductors while their inductances are being measured on a Digibridge is referred to as a Guarded Feed. This method allows high bias currents with little error as shown in the circuit in Figure 6. n impedance source feeds DC bias current to the "unknown" inductor,, while blocking the C signal to avoid excessive loading by the bias source. n "ideal' inductor of high value would be the best feed impedance because it would have high impedance at C but zero DC resistance. Ideal inductors are shown in Figure 6 but, of course, practical inductors have finite DC resistance and limited inductance. Switch La Cb + I+ (IH) Rg + Cd Lb Guard (ground) External P+ (PH) P (PL) I (IL) + Rs Digibridge Figure 6: Guarded Feed Circuit Requirements: Cb > 1 ω Rg La Lb 1 Cd 2 ω Lb

Bias Method (Continued) The Digibridge is capable of making measurements with considerable loading admittance from either end of the unknown to the guard (ground) connection. The guardedfeed method takes advantage of this guarding capability. Neither feed inductor is directly in parallel with, common with other measurement methods, therefore there is no shunting error introduced. lso, with this method the power supply is grounded so that commonmode hum is not a problem. There still are some sources of error, however, which require some necessary precautions. The capacitor Cb must be adequately large (Cb>1/2πfRg) and the feed inductor La should be approximately equal to or larger to avoid a reduction in signal level that would give poorer accuracy due to noise. The input of the inverting op amp is shunted by Lb, the second feed inductor. This causes an error of Rs/KωLb x 100% where K is the magnitude of the opamp gain at the test frequency. Table 2 lists typical values of gain for the Digibridge instruments at several test frequencies (the gain is inversely proportional to frequency). Usually, this error is negligible if Lb is roughly equal to, or larger than,. Table 1: Maximum Digibridge Bias Current 1659, 92, 89, & 93 Digibridge Range Rs I max 1 2 3 4 25 Ω 400 Ω 6.4 kω 102.4 kω 70 m 10 m 700 μ 40 μ Table 2: pproximate Gain* of Inverting mplifier Frequency 1659 1692 1689,93 120 Hz 240 Hz 1 khz 10 khz 100 khz 80,000 10,000 1,000 80,000 10,000 1,000 100 80,000 40,000 10,000 1,000 100 * Magnitude, K usually proportional to 1/f

Bias Method (Continued) blocking capacitor, Cd, is required in the I connection to keep the DC out of Rs and the inverting amplifier. The reactance of this capacitor should be much lower than that of Lb so that the C signal current will flow in Rs and be accurately measured thus Cd>100/ω 2 Lb. It is usually easy to find an electrolytic capacitor of suitable value. If it is too large, however, it will take excessive time to charge. Because both La and Lb may be moreorless equal to, this method is convenient if several similar inductors are to be measured, as would be the case in production or inspection situations. Even when similar inductors aren't available, the feed impedances required for this method, active or passive, are much lower than any other method because they only have to be of the same order as the impedance of and not substantially larger. Feed resistors rather than inductors are practical in some cases. For complete product specifications on the Digibridge Line of LCR meters or any of IET s products, visit us at http://www.ietlabs.com/digibridges.html Do you have an application specific testing need? Call us at 18008998436 or email engineering at sales@ietlabs.com and we ll work with you on a custom solution. Put IET to the test because we re committed to solving your testing requirements.