PolyGard Carbon Monoxide CO Transmitter ADTX3 1110



Similar documents
Carbon Monoxide (CO) Gas Detection and Control System

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Electronic Control Devices The European Product Catalogue 2007

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

Three-phase monitoring relay CM-PFE

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

How To Use A Ds340 (Dsp)

Electronic Control Devices The European Product Catalogue 2007

Digital display DA 48

The Ambient Air Monitoring System

Fire & Security DETECTORS

Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M 12, M 18, M 30

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Lockout Specification BW Clip Maintenance-free single gas detector

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

GREISINGER electronic GmbH

HERZ-Thermal Actuators

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Duct Humidity Transmitter

Buckeye Detection Systems Fixed Detection Systems Application Survey

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

IntesisBox Modbus Server SAMSUNG Air Conditioners

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

IntesisBox Modbus Server Fidelio IP

Analog signal converters CC-E I/I Current / current isolators

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

PIEZOMETER AIRFLOW MEASURING RING

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Technical Information RIA14

EXPLORER 4 MULTIPOINT

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Digital inductive conductivity transmitter

SECTION NOx, CO AND NATURAL GAS DETECTION, MONITORING AND ALARM CONTROL SYSTEMS

O C M III. Open Channel Flow Monitor

FX07 Field Controller

Ultima X Series Gas Monitors

Q U A D S C A N I I GENERAL User Interface Enclosure Display QUADSCAN II Temperature Range RECEIVER DISPLAY Sensor Weight Optional Relay Enclosure

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Overview of Standards for CO Detection Products

Multifunction devices

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

EBS852 (Contrac) Power Electronic Unit

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

Charge Regulator SCR 12 Marine

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Regards from the Team at Rheology Solutions.

ACS-30-EU-EMDR-10-MOD

WD-AMX Water Detection Controllers

Models SFP33 & SFP32 Pressure Transmitters

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

Energy Management Energy Meter Type EM23 DIN

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Digital input modules

How To Use A Flowmeter

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

API Marine. BMS Presentation. Ballast Measurement Systems

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Model SRMD Setra Remote Monitoring Display

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

Temp. & humidity Transmitter Instructions

RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Quick Connect. quick - simple - efficient.

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

psens Pressure Measurement

Radiant Temperature Sensor TY7321

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

RRV934. Multi-controller. Synco living

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

Messko. Messko. MTraB - Maintenance Free Dehydrating Breather Ordering specifications XX - XX - XXX - XX

Cable Plug acc. to DIN EN , Form A

FX07 Field Controller

Material test chamber with mechanical convection

Application/Connection Examples

ISO-9001:2000 certified. EE300 Series Electromechanical Inventory Level Measuring System. Aplus Finetek Sensor, Inc.

DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite:

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL

Electric Rotary Actuator - On/Off or programmable control actuator

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Transcription:

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110 DESCRIPTION CO transmitter including digital measurement value processing and temperature compensation for the continuous monitoring of the ambient air to detect carbon monoxide concentrations (CO). Comfortable calibration routine with selective access release is integrated in the transmitter. The ADT-03 possesses a standard analog output (0) 4-20 ma or (0) 2 10 V DC, and an RS-485 interface. 2 relays with adjustable switching thresholds are available as an option. APPLICATION For the detection of carbon monoxide (CO) within a wide range of commercial applications such as underground garages, tunnels, engine repair shops, loading bays, engine test benches, shelters, go-kart race courses etc. Due to the 4 to 20 ma output signal the CO transmitter is compatible to the PolyGard series MGC/DGC by MSR-E as well as to any other electronic control or automation system. Standard enclosure FEATURES Digital measurement value processing incl. temperature compensation. Continuous monitoring Low zero point drift Good stability to poisoning Long life sensor Modular plug-in technology Easy maintenance Comfortable calibration with selective access release Reverse polarity protected, overload and short-circuit proof (0) 4-20 ma / (0) 2 10V analog signal output, selectable Serial interface RS-485 (optional ModBus, BacNet MS/TP) IP65 protection Manual calibration via potentiometer (option) Manual addressing for RS-485 mode (option) 4 20 ma analog input for external transmitter (optional) Approved according to EN 61010-1; ANSI/UL 61010 1; CAN/CSA-C22.2 No. 61010-1 Relay output (optional) Integrated buzzer (optional) LED flashlight (optional) LCD display (optional) LED status display (optional) Heating (optional) Duct mounting (optional) MSR Electronic GmbH Würdingerstr. 27a 94060 Pocking GERMANY 1 Nov. 15

SPECIFICATIONS General sensor performance Detected gas Carbon monoxide (CO) Sensor element Electrochemical, diffusion Measuring range: - Standard - Optional 0 300 ppm 50 2000 ppm Pressure range Atmospheric ± 10 % Humidity range 15 90 % RH non-condensing Storage temperature 5 C to 30 C (41 F to 86 F) Storage time 6 months Mounting height 1.5 to 1.8 m (5 6 ft.) Sensor coverage 465 m 2, (5,000 sq.ft.), to 930 m 2 (10,000 sq.ft.) ideal conditions assumed Type ADT03-1110 Accuracy ± 3 ppm Repeatability ± 3 % of reading Long term zero-point drift < 5% signal loss/year Response time t 90 50 s Sensor life expectancy 5 years, normal operating environment Humidity range: Short-time 0 95 % RH non-condensing Working temp.: Continuous -10 C to + 50 C (14 F to 122 F) w/o heating Working temp.: Short-time -20 C to + 50 C (-4 F to 122 F) w/o heating Cross sensitivity* Concentration (ppm) Reaction (ppm) Acetone, C 3 H 6 O 1000 0 Acetylene, C 2 H 2 40 80 Ammonia, NH 3 100 0 Carbon dioxide, CO 2 5000 0 Chlorine, Cl 2 2 0 Ethanol, C 2 H 5 OH 2000 5 Hydrogen, H 2 100 20 Hydrogen Sulphide, H 2 S 25 0 Iso Propanol, C 3 H 8 O 200 0 Nitric oxide, NO 50 8 Nitrogen dioxide, NO 2 50-1,0 Sulphur dioxide, SO 2 50 < 0.5 Type ADT53-1110 Accuracy ± 1 ppm Repeatability ± 2 % of reading Long term sensitivity output drift < 2% signal loss/month Response time t 90 40 s Sensor life expectancy 3 years, normal operating environment Working temp.: Continuous -10 C to + 45 C (14 F to 113 F) w/o heating Working temp.: Short-time -20 C to + 50 C (-4 F to 122 F) w/o heating Cross sensitivity* Concentration (ppm) Reaction (ppm) Sulphur dioxide, SO 2 50 0 Hydrogen Sulphide, H 2 S 25 0 Nitrogen dioxide, NO 2 50 0 Nitric oxide, NO 50 0 Hydrogen, H 2 100 < 60 * The table doesn t claim to be complete. Other gases, too, can have an influence on the sensitivity. The mentioned cross sensitivity data are only reference values valid for new sensors. MSR Electronic GmbH Würdingerstr. 27a 94060 Pocking GERMANY 2 Nov. 15

Electrical Power supply 18-28 VDC/AC, (reverse polarity protected) (without options) 22 ma, max. (0.6 VA) Output signal Analog output signal (0) 4 20 ma, load 500, Selectable: Current / tension (0) 2-10 V, load 50 k Starting point 0 / 20 % proportional, overload and short-circuit proof Serial interface Transceiver RS 485 or optional BacNet MS/TP 9600 / 19200 / 38400 Baud (9600 at Mod_Bus) Physical characteristics Enclosure Plastic Type A* Polycarbonate Flammability UL 94 V2 Enclosure colour* RAL 7032 (light grey) Dimensions (W x H x D) 94 x 130 x 57 mm (3.7 x 5.12 x 2.24 inch.) Weight Approx. 0.5 kg (1.1 Ibs.) Protection class IP 65 Installation Wall mounting Cable entry Standard 1 x M 20 Wire connection Screw type terminal, min. 0.25 mm 2 (24 AWG) max. 2.5 mm 2 (14 AWG) Wire distance Current signal: ca. 500 m (1500 ft) Voltage signal: ca. 200 m (600 ft.) Certificates VDI 2053 German air treatment systems for car parks (pending) Guidelines EMC Directives 2004/108/EC EN 61010-1:2010 ANSI/UL 61010-1 CAN/CSA-C22.2 No. 61010-1 CE Warranty One year on material (without sensor) Options Relay output Alarm relay 1 30 VAC/DC, 0,5 A, potential-free, SPDT Alarm relay 2 30 VAC/DC, 0,5 A, potential-free, SPNO/SPNC 30 ma, (max 0.8 VA) Warning buzzer Acoustic pressure 85 db (distance 300 mm) (1 ft) Frequency 3.5 khz 30 ma, (max 0.8 VA) LCD Display LCD Two lines, each 16 characters 10 ma, (max 0.3 VA) LED display Green-yellow-red Supply, low alarm, high alarm 10 ma, (max. 0.3 VA) Heating Temperature controlled 3 C ±2 C (37.5 F ± 3.6 F) Ambient temperature - 40 C (- 40 F) 0.3 A; 7.5 VA Analog Input Only for RS-485 mode 4 20 ma overload and short-circuit proof, input resistance 200 Power supply for external transmitter 24 VDC max. 50 ma *For further enclosure types see datasheet ADT Enclosure. MSR Electronic GmbH Würdingerstr. 27a 94060 Pocking GERMANY 3 Nov. 15

ORDERING INFORMATION ADT-03-1110 X XXXXXXXXX Options 1XXXXXXXX Relay output 2 X1XXXXXXX Buzzer int. X2XXXXXXX Flashlight (LED) X3XXXXXXX Warning buzzer and flashlight XX1XXXXXX Heating XXXX1XXXX RS- 485 protocol for DGC-05 series XXXX2XXXX RS- 485 protocol ModBUS XXXX3XXXX RS- 485 protocol customers specification XXXXDXXXX MSR_D_Bus protocol 4 XXXXFXXXX BacNet MS/TP, Low-Adr.(1-60), 9600 Baud, ID1 4 XXXXGXXXX BacNet MS/TP, L-Adr.(1-60), 9600 Baud, ID6 4 XXXXHXXXX BacNet MS/TP, L-Adr.(1-60), 19200 Baud, ID6 4 XXXXIXXXX BacNet MS/TP, L-Adr.(1-60), 38400 Baud, ID6 4 XXXXJXXXX BacNet MS/TP, High-Adr. (61-120), 9600 Baud, ID1 4 XXXXKXXXX BacNet MS/TP, H-Adr. (61-120), 9600 Baud, ID6 4 XXXXLXXXX BacNet MS/TP, H-Adr. (61-120), 19200 Baud, ID6 4 XXXXMXXXX BacNet MS/TP, H-Adr. (61-120), 38400 Baud, ID6 4 XXXXX1XXX Calibration / addressing mode tool XXXXX2XXX Manual calibration XXXXX3XXX Manual addressing XXXXX4XXX Manual calibration / addressing XXXXXX1XX LCD display 3 XXXXXX2XX LED status display 2,3 XXXXXXX1X 4 20 ma analog input XXXXXXXX1 Factory calibration 0-300 ppm XXXXXXXX2 Factory calibration 0-150 ppm XXXXXXXX3 Factory calibration 0-200 ppm XXXXXXXX4 Factory calibration 0-100 ppm XXXXXXXX5 Factory calibration 0-50 ppm XXXXXXXX6 Factory calibration 0-400 ppm XXXXXXXX7 Factory calibration 0-500 ppm XXXXXXXX8 Factory calibration 0-1000 ppm XXXXXXXX9 Factory calibration 0-2000 ppm XXXXXXXXA Factory calibration 0-250 ppm Enclosure 1 A Plastic enclosure B Duct mounting 5 Stainless steel Sensor Type 0 Sensor Type ADT03-1110 5 Sensor Type ADT53-1110 1 See Data sheet PolyGard ADT Enclosure 2 Please indicate thresholds for low and high alarm when ordering. 3 Not in connection with stainless steel housing, not in connection with option Relay or RS-485 interface 4 Only in connection with manual calibration / addressing Example: CO transmitter, Sensor type ADT03-1110, stainless steel housing, tool mode, factory calibration 0-300 ppm Ordering No.: ADT-03-1110-5 XXXXX1XX1 MSR Electronic GmbH Würdingerstr. 27a 94060 Pocking GERMANY 4 Nov. 15

shield 4-20 ma 24 VDC 0 VDC Option Relay CONNECTING DIAGRAM Controller 7 6 5 4 3 2 1 X4 Bus_B Bus_A 4-20 ma_inp 4-20 ma 24 VDCOut 0 VDC 24 VDCInp R2 Transmitter ADTX3-11XX R1 1 NO 2 NC 3 COM 4 NO 5 COM X5 O VDC: Two wire mode only with 4 to 20 ma Output signal MSR Electronic GmbH Würdingerstr. 27a 94060 Pocking GERMANY 5 Nov. 15