Hydrophilic-Interaction Chromatography (HILIC) for LC-MS/MS Analysis of Monoamine Neurotransmitters using XBridge BEH Amide XP Columns

Similar documents
Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract

A Generic Kit-Based Approach for Quantifying Monoclonal Antibody Drugs Through Direct Digestion of Discovery Study Samples

Henry Shion, Robert Birdsall, Steve Cubbedge, and Weibin Chen Waters Corporation, Milford, MA, USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

UPLC-MS/MS Analysis of Aldosterone in Plasma for Clinical Research

Method Development of LC-MS/MS Analysis of Aminoglycoside Drugs: Challenges and Solutions

Discovery of Pesticide Protomers Using Routine Ion Mobility Screening

An Improved SPE-LC-MS/MS Method for the Quantification of Bradykinin in Human Plasma Using the ionkey/ms System

Analysis of Polyphenols in Fruit Juices Using ACQUITY UPLC H-Class with UV and MS Detection

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

Method Development for Size-Exclusion Chromatography of Monoclonal Antibodies and Higher Order Aggregates

How To Use An Acquity Qda Detector

Salman Azimi, 1 Nayan S. Mistry, 2 and Michelle Wood 2. Drug Quality Control Laboratory, Supreme Council of Health, Doha, Qatar 2

Advantages of Polar, Reversed- Phase HPLC Columns for the Analysis of Drug Metabolites

WATERS QUANTITATIVE ANALYSIS solutions

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Eleanor Riches Waters Corporation, Manchester, UK INTRODUCTION

MEDICINAL CHEMISTRY APPLICATIONS BOOK

Jennifer L. Simeone and Paul D. Rainville Waters Corporation, Milford, MA, USA A P P L I C AT ION B E N E F I T S INT RO DU C T ION

Fast and Automatic Mapping of Disulfide Bonds in a Monoclonal Antibody using SYNAPT G2 HDMS and BiopharmaLynx 1.3

Conversion of a USP Gas Chromatography Method to Convergence Chromatography: Analysis of Atropa Belladonna

Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

Rapid Screening Method for Illicit Drugs, Using an Advanced Solid Core UHPLC Column and UHPLC System with MS/MS Detection

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

XEVO TQ MS PHARMACEUTICAL APPLICATION NOTEBOOK

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

Advances in Steroid Panel Analysis with High Sensitivity LC/MS/MS. Kenneth C. Lewis 1, Lisa St. John-Williams 1, Changtong Hao 2, Sha Joshua Ye 2

Application of Structure-Based LC/MS Database Management for Forensic Analysis

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method

SIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC

Oasis HLB Cartridges and 96-Well Plates

SIMULTANEOUS QUANTITATIVE DETERMINATION OF OPIOID DEPENDENCY TREATMENT DRUGS IN HUMAN URINE USING UPLC/MS/MS

Protein Separation Technology

Robert Birdsall, Eoin Cosgrave, Henry Shion, and Weibin Chen Waters Corporation, Milford, MA, USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS

Improving the Metabolite Identification Process with Efficiency and Speed: LightSight Software for Metabolite Identification

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

Ultra Fast UHPLC-LCMSMS Method Development in Clinical Drug Monitoring

PosterREPRINT AN LC/MS ORTHOGONAL TOF (TIME OF FLIGHT) MASS SPECTROMETER WITH INCREASED TRANSMISSION, RESOLUTION, AND DYNAMIC RANGE OVERVIEW

Opiates in Urine by SAMHSA GC/MS

Supplementary Materials and Methods (Metabolomics analysis)

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Overview. Purpose. Methods. Results

[ DISQUE DISPERSIVE SAMPLE PREPARATION EXTRACTION PRODUCTS ] QuEChERS. Simplifed

United States Department of Agriculture Food Safety and Inspection Service, Office of Public Health Science

Making the Leap to LC/MS/MS: Enhancing and Accelerating Clinical Research and Forensic Toxicology Applications

Differentielle Ionen-Mobilität als Vorfilter für LC-MS/MS

Determination of Tetracycline Antibiotics in Milk Using a Simple Strong Cation-Exchange SPE Cleanup Procedure and LC-MS/MS Analysis

Separation of Peptides from Enzymatic Digestion on Different Acclaim Columns: A Comparative Study

Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control

AppNote 1/2014. Automated Hydrolysis, DPX Extraction and LC/MS/MS Analysis of Pain Management Drugs from Urine KEYWORDS ABSTRACT

Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances

The Essential CHROMacademy Guide. Mobile Phase Optimization Strategies for Reversed Phase HPLC

MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation

ApplicationNOTE Introduction

Thermo Scientific Syncronis HPLC Columns. Technical Manual

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

Comprehensive LC/MS Analysis of Illicit and Pain Management Drugs, Including Their Metabolites, in Urine

IC-MS and LC-MS Determination of Ionic Liquids, Counterions, and Impurities

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK

Contents. List of Contributors XIII The structure of The HPLC-Expert" Preface XVII

Analysis of Vegetable Oils by High Performance Liquid Chromatography

Metabolomic Profiling of Accurate Mass LC-MS/MS Data to Identify Unexpected Environmental Pollutants

Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

From HPLC to UHPLC and how to continue?

DRUG METABOLISM. Drug discovery & development solutions FOR DRUG METABOLISM

Screening and quantitative determination of drugs in diluted urine by UPLC-MS-MS

In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates

Matrix Effect in Bio-Analysis of Illicit Drugs with LC-MS/MS: Influence of Ionization Type, Sample Preparation, and Biofluid

How To Test For Contamination In Large Volume Water

AppNote 1/2012. Rapid Cleanup and Comprehensive Screening of Pain Management Drugs in Urine using Automated Disposable Pipette Extraction and LC-MS/MS

New drugs of abuse? A case study on Phenazepam & Methoxetamine

A feasibility study of the determination of B-group vitamins in food by HPLC with Mass Spectrometric detection. LGC/R/2011/181 LGC Limited 2011

DEVELOPMENT OF PFCs HIGH SENSITIVITY ANALYSIS METHOD APPLIED RETENTION GAP TECHNIQUE WITH UPLC/MS/MS

One Source Toxicology Laboratory, 1213 Genoa Red Bluff, Pasadena, Texas 77504

Structural Analysis of Labeled N-Glycans from Proteins by LC-MS/MS Separated Using a Novel Mixed-Mode Stationary Phase

Ádám Tölgyesi Joerg Stroka. Report EUR EN

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

Making the Leap to LC/MS/MS: Enhancing and Accelerating Clinical Research and Forensic Toxicology Applications

Micromass LCT User s Guide

The Theory of HPLC. Gradient HPLC

Waters Core Chromatography Training (2 Days)

MS/MS analysis of Polyphenols

Quick and Sensitive Analysis of Multiclass Veterinary Drug Residues in Meat, Plasma, and Milk on a Q Exactive Focus LC-MS System

Innovative vs Traditional

Transcription:

Hydrophilic-Interaction Chromatography (HILIC) for LC-MS/MS Analysis of Monoamine Neurotransmitters using XBridge BEH Amide XP Columns Jonathan P. Danaceau, Kenneth J. Fountain, and Erin E. Chambers Waters Corporation, Maple Street, Milford, MA, USA APPLICATION BENEFITS Retention and baseline resolution of monoamine neurotransmitters without the need for ion pairing reagents Short analysis time with low system backpressure allows the flexibility to substantially increase sample throughput Systematic method development strategies for HILIC. μm particle size provides the flexibility to operate on a variety of systems INTRODUCTION Hydrophilic-interaction chromatography (HILIC) is increasingly becoming a method of choice for the analysis of polar compounds [-]. One set of polar analytes that poses particular challenges are the monoamine neurotransmitters, dopamine (DA), serotonin (-HT), epinephrine (EP), and norepinephrine (NE). These compounds play a significant role in many mood, movement, and other neurological disorders such as depression, anxiety, schizophrenia, and Parkinson s disease [6-8]. These neurotransmitters also play a critical role in the effects and toxicity of drugs of abuse [9-]. This work presents the application of HILIC for the analysis of monoamine neurotransmitters using an XBridge BEH Amide XP column. Development of the successful chromatographic method depends upon the systematic optimization of organic mobile phase ionic strength to obtain the best peak shape and sensitivity. Choice of stationary phase and column temperature are also important. The resulting method achieves baseline separation for the most polar and challenging analytes in a short analysis time without the use of ion-pairing reagents that are often necessary in reversed-phase analysis of these compounds. WATERS SOLUTIONS XBridge BEH Amide XP Column ACQUITY UPLC System Xevo TQ-S Mass Spectrometer KEY WORDS HILIC, monoamines, LC-MS/MS, neurotransmitters, XP column

METHODS Combined stock standards of dopamine, norepenephrine, epinephrine, serotonin, and N-methyl serotonin (NMS) were prepared in methanol containing 0.% ascorbic acid and.% N HCl to prevent oxidation. Working standards of 00 ng/ml DA, NE, EP, -HT, and 0 ng/ml NMS were prepared fresh each day in starting mobile phase conditions. LC Conditions: Mass Spectrometry: LC System: ACQUITY UPLC MS System: Xevo TQ-S Column: XBridge BEH Amide XP,. μm;. x 7 mm. P/N 86006090 Column Temp: 0 C Sample Temp: C Ionization mode: Acquisition mode: Capillary Voltage: Cone voltage: ESI Positive MRM.0 kv Compound specific (see Table ) Mobile Phase A: Mobile Phase B: Needle Washes: 9: water:acetonitrile containing 00 mm NH HCOO, ph.0 8: acetonitrile:water containing 0 mm NH HCOO, ph.0 Strong and weak needle washes were both placed in MPB Desolvation Gas: 900 L/hr Cone Gas: 0 L/hr Desolvation Temp: 0 C Source Temp: 00 C Data was acquired and analyzed using MassLynx Software (V.; SCN 80). Initial mobile phase conditions were 0 MPB. The percentage of MPA was increased to over. min. The percentage of MPB was returned to 0 over 0. minute and held there for. min. The total cycle time was.0 min. The injection volume was 0 µl. Table. Mass spectral parameters used for analysis of monoamine neurotransmitters under HILIC conditions. Analyte MRM transition m/z Cone Voltage Collision Energy NMS 9.>60 0 -HT 77.0>60 8 DA >7 8 8 EP 8>66 8 NE >07 0 HILIC for Monoamines

RESULTS AND DISCUSSION: Optimization of Mobile Phase Composition Figure A shows the chromatography of monoamine neurotransmitters analyzed on the XBridge BEH Amide XP column. In order to achieve acceptable peak shape and resolution, it was necessary to carefully balance the ionic strength of MPB with solubility. 0 mm NH HCOO in MPB was required to achieve the chromatographic performance seen in Figure. The use of mobile phases with lesser ionic strength (0 and 0 mm) resulted in significant peak tailing and poor resolution between DA, EP, and NE, the most polar analytes, possibly due to secondary interactions with the stationary phase itself. Increasing the aqueous content of MPB to % ensured complete miscibility and prevented phase separation between water and acetonitrile that occurred at lower aqueous concentrations. Increasing the aqueous content alone resulted in a predictable decrease in retention for all compounds, but did not result in any improvements in peak shape or resolution between adjacent peaks. These changes are all consistent with the theory that increasing mobile phase ionic strength can disrupt secondary interactions with the stationary phase, resulting in improved chromatography. A 00 XBridge BEH Amide XP B 00 XBridge BEH HILIC XP 0.6 0.8.0...6.8.0.. min Figure : Chromatography of monoamine neutotransmitters on Waters BEH XBridge BEH Amide XP (A) and XBridge BEH HILIC XP (B) columns. Analyte key: -NMS, --HT, -DA, -EP, -NE. HILIC for Monoamines

Choice of Stationary Phase The performance of the XBridge BEH Amide XP column detailed above was compared to the unbonded hybrid particle (XBridge BEH HILIC XP). Preliminary work with 0 mm ammonium formate in MPA and MPB had shown that the compounds in this study exhibited better separation and resolution on the Amide column vs. the XBridge HILIC column. Comparison of the two columns using the optimized conditions described above confirmed those initial results. Figure B shows chromatograms of monoamine standards analyzed on the XBridge BEH HILIC XP column. Clearly, retention of nearly all analytes is superior on the Amide column as is the resolution between adjacent peaks. The superior performance of the Amide column may be attributable to its polar functional group. In an acidic environment (ph.0), the polar nature of the amide functionality may be more effective at interacting with the aqueous portion of the mobile phase and forming the stagnant water layer required for HILIC chromatography. Effect of Temperature on HILIC Chromatography HILIC chromatography can be quite sensitive to temperature, and both decreases and increases in retention have been seen with temperature increases [, ]. Figure shows chromatograms of monoamines run under the mobile phase conditions used in Figure A at different temperatures. In general, as temperature increased, the resolution between peaks decreased. At 0 C, there is a decrease in the resolution between dopamine and epinephrine and at 60 C, baseline separation has clearly been lost. Interestingly, when the column was cooled to 0 C, there was a significant loss of peak shape for NMS. As this figure clearly shows, 0 C provided the optimum balance of speed, resolution, and peak shape for all analytes. 00 0 C 00 0 C 00 0 C 00 0 C 00 60 C 0.6 0.8.0...6.8.0.. min Figure : Effect of changes in column temperature on monoamine chromatography. Analyte key: -NMS, --HT, -DA, -EP, -NE. HILIC for Monoamines

CONCLUSIONS The development of HILIC chromatography for the analysis of monoamine neurotransmitters using a. µm particle column is detailed. Optimizing the ionic strength of the organic mobile phase proved critical to maximizing chromatographic performance, but needed to be balanced with increases in aqueous content to ensure complete solubility. The superior performance of the XBridge BEH Amide XP column demonstrates the importance of stationary phase choice considerations during HILIC method development. Column temperature is also shown to be a crucial consideration for optimizing chromatography. These results show that retention, separation and resolution of even the most polar compounds (epinephrine and norepinephrine) can be readily achieved. The intermediate length of the column (7 mm) combined with the relatively low backpressures characteristic of HILIC analyses should afford ample flexibility to adapt this method as needed. REFERENCES. Cubbon S, Antonio C, Wilson J, Thomas-Oates J: Metabolomic applications of HILIC LC MS. Mass Spectrometry Reviews 9(), 67-68 (00).. Jian W, Edom RW, Xu Y, Weng N: Recent advances in application of hydrophilic interaction chromatography for quantitative bioanalysis. Journal of Separation Science (6-7), 68-697 (00).. Xu RN, Rieser MJ, El-Shourbagy TA: Bioanalytical hydrophilic interaction chromatography: recent challenges, solutions and applications. Bioanalysis (), 9- (009).. Jian W, Xu Y, Edom RW, Weng N: Analysis of polar metabolites by hydrophilic interaction chromatography MS/MS. Bioanalysis (8), 899-9 (0).. Hemström P, Irgum K: Hydrophilic interaction chromatography. Journal of Separation Science 9(), 78-8 (006). 6. Mellon SH, Griffin LD: Neurosteroids: biochemistry and clinical significance. Trends in Endocrinology & Metabolism (), - (00). 7. Schumacher M, Weill-Engerer S, Liere P et al.: Steroid hormones and neurosteroids in normal and pathological aging of the nervous system. Progress in Neurobiology 7(), -9 (00). 8. Shah AJ, Crespi F, Heidbreder C: Amino acid neurotransmitters: separation approaches and diagnostic value. Journal of Chromatography B 78(-), -6 (00). 9. Hill SL, Thomas SHL: Clinical toxicology of newer recreational drugs. Clinical Toxicology 9(8), 70-79 (0). 0. Schep LJ, Slaughter RJ, Beasley DMG: The clinical toxicology of metamfetamine. Clinical Toxicology 8(7), 67-69 (00).. Seger D: Cocaine, metamfetamine, and MDMA abuse: the role and clinical importance of neuroadaptation. Clinical Toxicology 8(7), 69-708 (00).. Fountain KJ, Xu J, Diehl DM, Morrison D: Influence of stationary phase chemistry and mobile-phase composition on retention, selectivity, and MS response in hydrophilic interaction chromatography. Journal of Separation Science (6-7), 70-7 (00).. Hao Z, Xiao B, Weng N: Impact of column temperature and mobile phase components on selectivity of hydrophilic interaction chromatography (HILIC). Journal of Separation Science (9), 9-6 (008). 0 Waters Corporation. Waters, The Science of What s Possible, XBridge, ACQUITY UPLC, Xevo, and MassLynx are trademarks of Waters Corporation. June 0 700089EN IH-PDF Waters Corporation Maple Street Milford, MA 077 U.S.A. T: 08 78 000 F: 08 87 990 www.waters.com