HIGH VOLTAGE SHORE CONNECTION



Similar documents
Electrical Shore Connections / Cold Ironing

Unified requirements for systems with voltages above 1 kv up to 15 kv

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

SURGE PROTECTIVE DEVICES

FAQs-Main switchboard design criteria

Switchgear and Metal-Enclosed Bus

Federal Wage System Job Grading Standards for Electric Power Controlling, Table of Contents

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

National Craft Assessment and Certification Program S P E C I F I C A T I O N S

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

IEC specifications for LV assembly switchboards

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Part 1 System Modeling & Studies for Existing Systems

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

Short Circuit Current Calculations

Product brochure Multi Functional Switchgear PASS M kv Flexible and compact switchgear solutions for windfarms

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V V V (at 50 Hz)

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

Earth Fault Detection Basics in Theory

NZECP 14: 1995 ISSN COVER PAGE

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.

Trial Exams C. Standards and Regulations. Examination No: GH-08-C- 1 hour and 5 minutes plus 10 minutes reading time

USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES

Charging what can be more simple? SAE J1772

User Manual 1K/2K/3K Online UPS

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Requirements concerning ELECTRICAL INSTALLATIONS

PART C SECTION 5 SUBSECTION 5B

VDE Information. Degree of Pollution, Clearances and Creepage Distances and Insulating Materials

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

IEC & 2 standard. The reference for safe and reliable LV switchboards

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

ELECTRICIAN TRADE REGULATION

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

Standards in Marine Power Systems. APEC 2014 Session IS2.1 Power Electronic Standards Roger Dougal University of South Carolina Columbia, SC 29208

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

TOSHIBA G /100/160/225 kva

INTERNATIONAL STANDARD

Permissible ambient temperature Operation Storage, transport

Online UPS. PowerWalker VFI 1000R/1U

Fusible Disconnect Switch

Electric Power Distribution

How To Choose A Transformer

Oil and Coolant Circulating Heating System. Model - OCSM

Hyperlinks are Inactive

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Power transformers. Special transformers Railway

PowlVac Vacuum Integrity Tester

(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS

HAZARDS, INCLUDING SHOCK, ARC FLASH AND FIRE

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

AS/NZS 3000:2007 Amendment 2

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

The electrical energy produced at the gen

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

Arc Terminator Active Arc-Resistant Switchgear

1. Electrical Equipment A) Transformer

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

This section applies to the design and installation of transformers.

2004 TRANSMISSION SYSTEMS SEMINAR MEDIUM VOLTAGE, METAL-CLAD ARC RESISTANT SWITCHGEAR: ENHANCING WORKPLACE SAFETY

CHECKING AND TESTING ELECTRICAL INSTALLING WORK

Atlanta Chapter IEEE Industry Applications Society

A. Shop Drawing submittals shall include, but not be limited to, the following:

How To Use A Power Supply Unit (Upu)

3000W Power Inverter

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Evaluating Water-Damaged Electrical Equipment

Low Voltage Switchboards The Best Technical Solution for Your Ship

Fundamentals of Power

CAPACITOR BANK TESTING SWP

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

Electronic overload relay EF65, EF96 and EF146

Powerware 5110 UPS User s manual

SECTION ELECTRICAL ACCEPTANCE TESTS

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

Single-Phase AC Synchronous Generator

Safety technique. Emergency stop module BO 5988 safemaster

BRANDON AND CLARK INC. // SCOTT W. CLARK, P.E. ELECTRICAL CONTINUING EDUCATION ARC FLASH - NFPA 70E

CHAPTER VIII LINE PLANT SYSTEM COMMUNICATION THROUGH RE CABLE

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

How To Understand The Electrical Power Supply Of A Power Supply System

Application of Four-Pole Circuit Breakers within Data Centers

Regulation IO-6.0: Electrical Safety Regulations

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST

Transcription:

Guide for High Voltage Shore Connection GUIDE FOR HIGH VOLTAGE SHORE CONNECTION NOVEMBER 2011 American Bureau of Shipping Incorporated by Act of Legislature of the State of New York 1862 Copyright 2011 American Bureau of Shipping ABS Plaza 16855 Northchase Drive Houston, TX 77060 USA

Foreword Foreword It is envisaged that the effect of increasingly stricter air emissions legislation implemented through mainly local air quality controls will see an increasing number of vessels installing high voltage shore connection (HVSC) in the near future. Shore power supply facilities have adopted high voltage rather than low voltage by necessity in order to keep the physical size of related electrical equipment such as shore connection cables manageable. Inevitably high voltage would otherwise introduce new risks to ship s crew and the shipboard installations if necessary safety features were not built into the HVSC system or safe operating procedures were not put in place. Accordingly, the requirements of this Guide have been developed with the primary focus on the safety of operating crews as well as for the security of the shipboard equipment. It should be noted that the requirements in this Guide have been developed in consideration of the joint effort by IEC, ISO and IEEE to establish an international standard for Cold Ironing High Voltage Connection Systems which at the time of the issuance of this Guide is under development. The applicable edition of the Rules for Building and Classing Steel Vessels is to be used in association with the subject Guide. This Guide becomes effective on the first day of the month of publication. Users are advised to check periodically on the ABS website www.eagle.org to verify that this version of this Guide is the most current. We welcome your feedback. Comments or suggestions can be sent electronically by email to 0rsd@eagle.org. ii ABS GUIDE FOR HIGH VOLTAGE SHORE CONNECTION. 2011

Table of Contents GUIDE FOR HIGH VOLTAGE SHORE CONNECTION CONTENTS 1 Application... 1 2 Objectives... 1 3 Classification Notation... 1 4 Plans and Data to be Submitted... 1 5 Definitions... 2 6 Alternative Arrangements... 2 7 System Design... 2 7.1 Shore Power Compatibility...2 7.2 Capacity...2 7.3 Grounding...3 7.4 Circuit Protection...5 7.5 Short-circuit Level Compatibility...5 7.6 Overvoltage Protection...5 7.7 Protective Device Coordination...5 7.8 Protection of Transformer...5 7.9 Load Transfer...5 7.10 Failure Recovery Strategy...6 7.11 Safety Interlocks...6 7.12 HVSC Circuit Breaker Control...7 7.13 HVSC Emergency Shutdown...7 7.14 Harmonics...7 7.15 Monitoring and Alarms...7 8 Equipment Design... 8 8.1 General...8 8.2 Protection Against Moisture and Condensation...8 8.3 Air Clearance...8 8.4 Creepage Distance...8 8.5 Shore Connection Switchboard...8 8.6 Onboard Receiving Switchboard...8 8.7 Cable Management System...9 8.8 Shore Connection Plugs and Receptacle...9 8.9 Transformer...9 8.10 HV Cables...9 ABS GUIDE FOR HIGH VOLTAGE SHORE CONNECTION. 2011 iii

9 Installations... 10 9.1 Equipment Locations...10 9.2 Voltage Segregation...10 9.3 HV Cable Installation...10 9.4 Storage...11 10 Maintenance Plan... 11 11 Operation Manual... 11 12 Tests... 11 12.1 HV Switchboard...12 12.2 HV Transformer...12 12.3 HV Cable Reel Slip Ring...12 12.4 Cable Test After Installation...12 TABLE-1 Air Clearance...8 TABLE 2 AC Withstand Test...12 FIGURE 1 FIGURE 2 FIGURE 3 FIGURE 4 FIGURE 5 Example for Ungrounded LV Ship s System...3 Example for Grounded HV Ship s System (where NGR Value is Compatible with the Ship s Design Ground Current Range, Otherwise 1:1 Isolation Transformer may be Required)...4 Example for Ungrounded Ship s System (e.g., Oil Carriers and Gas Carriers)...4 Example for Ungrounded Ship s System where Shoreside Option for Ungrounded Neutral is Available (e.g., Oil Carriers and Gas Carriers)...5 Example of Plug and Socket, interlock by Pilot Contactor...10 iv ABS GUIDE FOR HIGH VOLTAGE SHORE CONNECTION. 2011

1 Application Requirements in this Guide apply to vessels equipped with a high voltage shore connection system (HVCS) designed to power the vessel with the shore power alone, enabling the shipboard generators to be shut down while in port. The installation of a HVSC is optional, however if installed it is to be designed, installed and surveyed in accordance with this Guide, and when found satisfactory, a classification notation as specified in Section 3 will be granted. 2 Objectives The objective of this Guide is to provide requirements for the design, installation and survey of high voltage shore connection installations. The requirements in this Guide address: i) The safety of shipboard and, where applicable, shoreside personnel during the deployment and retrieval of the cable and when making the HV connection. ii) iii) iv) The safety of shipboard personnel during the period in which the vessel is operating using the established HV shoreside connection. The safety of the shipboard personnel should the HV connection malfunction. The safety of shipboard personnel and shoreside staff as applicable at the time the HV connection between the vessel and the shoreside supply is disconnected. v) Requirements for the safe storage of the HV equipment and associated connections when the vessel is on voyage or in ports where no HV connection is established. These objectives are to be achieved by means of the system design, the construction of the HV equipment and operating safety procedures. 3 Classification Notation A vessel with a high voltage shore connection installation which is found to be in compliance with the requirements in this Guide will be assigned the classification notation HVSC. 4 Plans and Data to be Submitted The following plans and data are to be submitted: i) One-line diagram showing shipboard elements of the HVSC ii) Descriptions of Electrical System Grounding philosophy (See Section 5 and 7.3.3) iii) Descriptions of instrumentation, monitoring and alarms iv) Short-circuit current calculations for each shore facility v) Protection device coordination study for each shore facility vi) Load analysis vii) Capacity rating of HVSC installation, including maximum design short-circuit level viii) Details of shore connection switchboard, including outline view, internal arrangement, dimensions, IP rating, circuit breaker rating, socket rating and schematics ix) Details of transformer including kva rating, impedance information and construction details ABS GUIDE FOR HIGH VOLTAGE SHORE CONNECTION. 2011 1

x) Cable specifications xi) xii) Details of portions of the ship s main switchboard that are associated with the HVSC interface Descriptions of the automatic synchronization system for the temporary generator parallel running of ship s generator and the shore power, if fitted xiii) Descriptions of safety interlocks (See 7.11) xiv) xv) Details of the cable management system, if installed Equipment locations, including the routing of HV cables xvi) Operation manual as required by Section 11 5 Definitions High Voltage Shore Connection (HVSC) Installation: Those onboard systems that are designed to accept high voltage shore power, typically involving incoming power receptacles, shore connection switchgear, step-down transformer or isolation transformer, fixed power cables, incoming switchgear at the main switchboard and associated instrumentation. HVSC is often referred to as Cold Ironing or Alternative Marine Power. High Voltage (HV): For the purpose of this Guide, the system nominal voltage is considered to be in the range from 1 kv AC to 15 kv AC. Electrical System Grounding Philosophy: The manner in which electrical system is grounded (e.g., ungrounded system, solid neutral grounding system, low impedance neutral grounding system, or high impedance neutral grounding system), including ground potential transformer method. Circuit protection strategy is built around the selected method of system grounding in terms of over voltage prevention, over current prevention or continued operability under single phase grounded condition. Cable Management System: The cable management system is the ship s interface point with the shore power system. The cable management system is typically composed of flexible HV cables with the plug that extends to the shore power receptacle, cable reel, automatic tension control system with associated control gears, and instrumentation. Shore power is fed to the shore connection switchboard via the cable management system. Shore Connection Switchboard: Where no cable management system is provided onboard, the shore connection switchboard is normally the ship s interface point with the shore power system. HV shore power is connected to this shore connection switchboard by means of an HV plug and socket arrangement. The shore connection switchboard is provided with a shore power connecting circuit breaker with circuit protection devices. Onboard Receiving Switchboard: The receiving switchboard is normally a part of the ship s main switchboard to which the shore power is fed from the shore connection switchboard. 6 Alternative Arrangements Alternative arrangements that differ from the specific requirements in this Guide and that provide an equivalent level of safety may be considered on their technical merits. 7 System Design 7.1 Shore Power Compatibility Means to check shore power compatibility (e.g., correct voltage range, frequency and phase rotation) are to be provided at the location from which the HVSC circuit breakers are controlled (e.g., at the control station in the engine control room). 2 ABS GUIDE FOR HIGH VOLTAGE SHORE CONNECTION. 2011

7.2 Capacity HVSC installation is to be sufficiently rated to supply the following: i) Normal services required in port ii) Emergency services iii) Services needed to support the ship s operations in port 7.3 Grounding 7.3.1 Equipotential Bonding Equipotential bonding between the ship and the shore is to be provided. An interlock is provided such that the HV shore connection cannot be established until the equipotential bonding has been established. The bonding cable may be integrated into the HV shore power cable. If the equipotential bonding cable is intended to carry the shipboard ground fault current, the cable size is to be sufficient to carry the design maximum ground fault current. 7.3.2 Equipotential Bonding Safety Interlock An interlock arrangement is to be provided such that the loss of equipotential bonding is to result in the disconnection of the HV shore power. See 7.13.2i). 7.3.3 System Grounding Compatibility Arrangements are to be provided so that when the shore connection is established, the resulting system grounding onboard is to be compatible with the vessel s original electrical system grounding philosophy (for instance, the shipboard ungrounded power distribution system is to remain ungrounded, or the shipboard high impedance grounding system is to remain high impedance grounded within the design grounding impedance values). Ground fault detection and protection is to remain available after the shore connection has been established. Examples are shown in Figures 1 through 4. 7.3.4 Voltage rating The voltage rating of electrical equipment insulation materials is to be appropriate to the system grounding method, taking into consideration the fact that the insulation material will be subjected to 3 times higher voltage under single phase ground fault condition. FIGURE 1 Example for Ungrounded LV Ship s System Shore Side Ship Side (Ungrounded, Low Voltage) Step-down Transformer HV Transformer Secondary: 6.6 kv 440V NGR Equipotential bonding to the ship's hull ABS GUIDE FOR HIGH VOLTAGE SHORE CONNECTION. 2011 3

FIGURE 2 Example for Grounded HV Ship s System (where NGR Value is Compatible with the Ship s Design Ground Current Range, Otherwise 1:1 Isolation Transformer may be Required) Shore Side Ship Side (High Impedance Grounding) HV Transformer Secondary: 6.6 kv 6.6 kv NGR Equipotential bonding to the ship's hull FIGURE 3 Example for Ungrounded Ship s System (e.g., Oil Carriers and Gas Carriers) Shore Side Ship Side (Ungrounded, or High Impedance Grounding via GPT) 1:1 Isolation Transformer HV Transformer Secondary: 6.6 kv 6.6 kv Low Impedance NGR Equipotential bonding to the ship's hull 4 ABS GUIDE FOR HIGH VOLTAGE SHORE CONNECTION. 2011

FIGURE 4 Example for Ungrounded Ship s System where Shoreside Option for Ungrounded Neutral is Available (e.g., Oil Carriers and Gas Carriers) Shore Side Ship Side (Ungrounded, or High Impedance Grounding via GPT) HV Transformer Secondary: 6.6 kv 6.6 kv NGR Equipotential bonding to the ship's hull 7.4 Circuit Protection The HV shore connection switchboard is to be provided with a circuit breaker to protect fixed HV electrical cables installed from that point onward. 7.5 Short-circuit Level Compatibility After a shore connection has been established, the prospective short-circuit current level at any point in the ship s power distribution system is not to exceed the short-circuit breaking and making capacities of circuit breakers installed onboard. Operational procedures are to be established for assessment of the shoreside impedance, which determines the prospective short-circuit current level after the shore connection has been established. Procedures are to be included in the operation manual. 7.6 Overvoltage Protection Where a step-down transformer is installed onboard, the ship s low voltage system is to be protected against accidental overvoltage. This may be achieved by: i) Direct earthing of the lower voltage system while the shore power is connected ii) Earthed screen between the primary and the secondary windings of the transformer 7.7 Protective Device Coordination The feeder circuit breaker on the main switchboard serving the shore connection is to be coordinated with the generator circuit breakers such that a short-circuit fault in the shore connection circuit will not result in a blackout condition. 7.8 Protection of Transformer Transformer, where provided, is to be protected against short-circuit and overload protection in accordance with 4-8-2/9.19 of the ABS Rules for Building and Classing Steel Vessels (Steel Vessel Rules). The overload protection device must have time-current protection characteristics consistent with the transformer s thermal damage characteristics. ABS GUIDE FOR HIGH VOLTAGE SHORE CONNECTION. 2011 5

7.9 Load Transfer 7.9.1 Temporary Parallel Running Where the shipboard generator is intended to run in parallel with the shore power for a short period of time for the purpose of connecting to the shore power or back to ship power without going through a blackout period, the following requirements are to be complied with: i) Means are to be provided to verify that the incoming voltage is within the range for which the shipboard generator can be adjusted with its automatic voltage regulator (AVR) ii) iii) iv) Means are to be provided for automatic synchronization Load transfer is to be automatic The duration of the temporary parallel running is to be as short a period as practicable allowing for the safe transfer of the load. In determining the rate of the gradual load transfer, due regard is to be paid to the governor characteristics of shipboard generator in order not to cause excessive voltage drop and frequency dip. 7.9.2 Load Transfer via Blackout Where load transfer is executed via blackout (i.e., without temporary generator parallel running), safety interlock arrangements are to be provided so that the circuit breaker for the shore power at the shore connection switchboard cannot be closed while the HV switchboard is live with running shipboard generator(s). 7.10 Failure Recovery Strategy In the event of a shore power failure, the shipboard power is automatically restored to an extent that the safe operations of the ship can be maintained. Detailed procedures for the failure recovery are to be included in the operation manual. 7.11 Safety Interlocks An interlock, which prevents plugging and unplugging of the HV plug and socket outlet arrangements while they are energized, is to be provided. 7.11.1 Handling of HV Plug While the HV shore connection circuit breakers are in the open position, the conductors of the HV supply cables are to be automatically kept earthed by means of an earthing switch. A set of pilot contactors embedded in the HV plug and socket-outlet may be used for this purpose. The earthing switch control is to be designed based on a fail-to-safe concept such that the failure of the control system will not result in the closure of the earthing switch onto the live HV lines. 7.11.2 HV Shore Connection Circuit Breakers Arrangements are to be provided to prevent the closing of the shore connection circuit breaker when any of the following conditions exist: i) Equipotential bonding is not established ii) The pilot contact circuit is not established iii) Emergency shutdown facilities are activated iv) An error within the HV connection system that could pose an unacceptable risk to the safe supply of shoreside power to the vessel. These errors may occur within the alarm system, whether on board the ship or at the shoreside control position, or within any relevant safety systems including those which monitor system performance. v) The HV supply is not present 7.11.3 Closing of Shoreside HVSC Circuit Breaker Arrangements are to be provided such that the shoreside HVSC circuit breaker may be closed after the ship side sends a permission to close signal to the shore. Such arrangements may be based on an interlock or visual signal. 6 ABS GUIDE FOR HIGH VOLTAGE SHORE CONNECTION. 2011

7.12 HVSC Circuit Breaker Control HV shore connection circuit breakers are to be remotely operated away from the HVSC equipment. Operational procedures are to be established that state that the attempts to close HV shore connection circuit breakers are to be made only when it has been established that personnel are evacuated from the HV shore connection equipment compartments. The operation manual is to describe these established procedures. 7.13 HVSC Emergency Shutdown 7.13.1 In the event of an emergency, the HV system shall be provided with shutdown facilities that immediately open the shore connection circuit breaker. These emergency shutdown systems are to be automatically activated. 7.13.2 7.13.3 7.13.4 Any of the following conditions are to cause emergency shutdown of the shore power supply: i) Loss of equipotential bonding ii) High tension level of HV flexible shore connection cable, or low remaining cable length of cable management system iii) Shore connection safety circuits fail iv) The emergency stop button is used (see 7.13.3) v) Any attempts to disengage the HV plug while live (this may be achieved by the pilot contactors embedded in the plug and socket such that the pilot contactors disengage before the phase contactors can disengage) Emergency stop buttons that initiate emergency shutdown systems are to be provided: i) At the remote location from which the HVSC circuit breakers are controlled (see 7.12) ii) At the shipboard control center for management of the cable and connection and at additional control locations, as applicable and deemed necessary iii) At the shore connection switchboard Emergency stop buttons are to be clearly marked so that their method of operation is visible, legible and easily followed. Positioning of the emergency stop buttons and attendant operational instructions should be such as to prevent accidental or inadvertent operation. Once activated, the emergency stop button should require manual action to reset. Activation of the emergency stop button is to result in a clearly visible visual warning and easily recognizable audible alarm. Following the emergency shutdown, the ship s electrical power is to be automatically restored. See 7.10. 7.14 Harmonics Where power converter equipment is provided within the shore connection system in order to obtain desired voltage and/or frequency, the total voltage harmonic distortion of the converter is not to exceed 5 percent at any operating load. ABS GUIDE FOR HIGH VOLTAGE SHORE CONNECTION. 2011 7

7.15 Monitoring and Alarms The following monitoring and alarms are to be provided at the location from which the HVSC circuit breakers are controlled, and at other strategic locations that are normally manned if deemed necessary: i) Overtension alarm on HV flexible shore connection cables, or cable management system overdeployment (low remaining cable length) alarm, prior to the emergency shutdown [see 7.13.2ii)] ii) The loss of shore power iii) Emergency shutdown iv) Manual emergency-stop v) Safety device activation alarms (e.g., overcurrent, earth fault) 8 Equipment Design 8.1 General Electrical equipment is to be constructed of durable, flame-retardant, moisture-resistant material, which are not subject to deterioration in the marine environment and at the temperatures to which it is likely to be exposed. The determination of equipment protection class (IP rating) is to be in accordance with 4-8-3/Table-2 of the Steel Vessel Rules. 8.2 Protection Against Moisture and Condensation Means are to be provided to prevent accumulation of moisture and condensation. 8.3 Air Clearance Phase-to-phase air clearances and phase-to-earth air clearances between non-insulated parts are to be not less than the minimum, as specified in Table-1. Nominal Voltage kv TABLE-1 Air Clearance Minimum Air Clearance mm (in.) 3-3.3 55 (2.2) 6-6.6 90 (3.6) 10-11 120 (4.8) Where intermediate values of nominal voltages are accepted, the next highest air clearance is to be observed. 8.4 Creepage Distance Creepage distances between live parts and between live parts and earthed metal parts are to be adequate for the nominal voltage of the system, due regard being paid to the comparative tracking index of insulating materials under moist conditions according to the IEC Publication 60112 and to the transient overvoltage developed by switching and fault conditions. 8.5 Shore Connection Switchboard 8.5.1 Construction The HV shore connection switchboard is to be designed, manufactured and tested in accordance with a recognized standard such as IEC 62271-200. 8 ABS GUIDE FOR HIGH VOLTAGE SHORE CONNECTION. 2011

8.5.2 Circuit Breaker i) Shore connection HV circuit breaker is to be equipped with low voltage protection (LVP) ii) iii) iv) 8.6 Onboard Receiving Switchboard The rated short-circuit making capacity of the circuit breaker is not to be less than the prospective peak value of the short-circuit current The rated short-circuit breaking capacity of the circuit breaker is not to be less than the maximum prospective symmetrical short-circuit current HV shore connection circuit breaker is to be remotely operated 8.6.1 Construction The HV shore connection switchboard is to be designed, manufactured and tested in accordance with a recognized standard such as IEC 62271-200. 8.6.2 Instrumentation The receiving switchboard is to be equipped with: i) Voltmeter(s), all three phases, for the shore power and the shipboard power ii) Phase rotation indicator for the shore power iii) Frequency meter(s) for the shore power and the shipboard power iv) Ammeter for the shore power, all three phases v) Synchronizing device, see 7.9.1 vi) Short-circuit protection vii) Overcurrent protection viii) Earth-fault detection 8.6.3 Circuit Breaker i) The rated short-circuit making capacity of the circuit breaker is not to be less than the prospective peak value of the short-circuit current ii) iii) The rated short-circuit breaking capacity of the circuit breaker is not to be less than the maximum prospective symmetrical short-circuit current HV shore connection circuit breaker is to be remotely operated 8.7 Cable Management System The cable management system is to allow extending cable and retracting cable without causing undue stress to the cable. The slip ring, where provided, is to be tested in accordance with 12.3. 8.8 Shore Connection Plugs and Receptacle i) Interlock between the plug and the shore connection circuit breaker is to be provided such that the plug can be disengaged only after the shore connection circuit breaker has been opened. This may be achieved by the construction of a plug and socket. An example is shown in Figure 5. ii) Plugs and sockets are to be protected from dust, moisture and condensation while not in use. The minimum protection rating of plugs and sockets is to be IP66. An example of the socket is shown in Figure 5. 8.9 Transformer Where provided, the transformer is to be in compliance with the requirements of 4-8-5/3.7.5 of the Steel Vessel Rules. In determining the continuous rating of the transformer, the level of harmonics current is to be taken into consideration. ABS GUIDE FOR HIGH VOLTAGE SHORE CONNECTION. 2011 9

8.10 HV Cables Shipboard fixed HV cables are to be in compliance with IEC 600092-353, 600092-354 or other relevant standards acceptable to ABS. Non-fixed HV cables are to be constructed and tested to recognized standard acceptable to ABS. FIGURE 5 Example of Plug and Socket, interlock by Pilot Contactor (The pilot contactor disengages before the phase conductors disengage) Note: Image courtesy of CAVOTEC. 9 Installations 9.1 Equipment Locations i) Access to HVSC equipment is to be subject to appropriate controls. ii) The shore connection switchboard is to be located in a compartment that is sheltered from the weather. HV shore cables are to enter this compartment through a temporary opening with weathertight arrangements iii) iv) This compartment is not to have any opening(s) within a designated hazardous area Ample space around the shore connection switchboard is to be available for the operating crew to freely perform connecting and disconnecting operations 9.2 Voltage Segregation Higher voltage equipment is not to be combined with low voltage equipment in the same enclosure, unless segregation or other suitable measures are taken to provide safe access to lower voltage equipment. 10 ABS GUIDE FOR HIGH VOLTAGE SHORE CONNECTION. 2011

9.3 HV Cable Installation 9.3.1 Runs of Cables In accommodation spaces, high voltage cables are to be run in enclosed cable transit systems. 9.3.2 Segregation High voltage cables are not to be installed on the same cable tray for the cables operating at the nominal system voltage of 1 kv or less. 9.3.3 Installation Arrangements High voltage cables are to be installed on cable trays or equivalent when they are provided with a continuous metallic sheath or armor which is effectively bonded to earth; otherwise, they are to be installed for their entire length in metallic casings effectively bonded to earth. 9.3.4 Marking High voltage cables are to be readily identifiable by suitable marking. 9.4 Storage Appropriate arrangements are to be provided for storage of removable HVSC equipment when not in use. Such storage should take into account issues such as, but not restricted to, temperature, humidity, moisture, condensation, dirt, and dust, and should protect against the likelihood of physical damage to the cable, plugs, sockets, and associated equipment. 10 Maintenance Plan A maintenance plan is to be developed to establish periodic tests and maintenance procedures for the HVSC system. The maintenance plan is to be included in the Operation Manual. 11 Operation Manual A manual depicting operational procedures for the HV shore connection system is to be readily available for the operating crew. The manual is to include, but not limited to, the following: i) Operating crews qualification requirements ii) Shore power compatibility assessment procedures, including acceptable voltage tolerance, frequency and correct phase rotation, the shoreside source impedance for the assessment of prospective short circuit current, and the shoreside neutral grounding method for the assessment of ship s system grounding compatibility (see 7.3.3) iii) iv) Operational procedures to establish actions to be taken when the shore power is found not compatible with the shipboard system. Step-by-step instructions to establish shore connection and disconnection, including equipotential bonding and load transfer v) Procedures for sending to the shore permission to close shoreside HVSC circuit breaker (see 7.11.3) vi) Emergency shutdown procedures (see 7.13) vii) Failure recovery procedures (see 7.10) viii) Storage requirements for HVSC equipment (see 9.4) ix) HVSC system maintenance plan (see Section 10) The operation manual is to be readily available for operators at the operating stations ABS GUIDE FOR HIGH VOLTAGE SHORE CONNECTION. 2011 11

12 Tests 12.1 HV Switchboard 12.1.1 Type Test HV switchboards are to be subjected to an AC withstand voltage test in accordance with Table-2 or other relevant national or international standards. A test is to be carried out at the manufacturer s test facility in the presence of the Surveyor. 12.1.2 Onboard Test After installation onboard, the HV switchboard is to be subjected to an insulation resistance test in accordance with Table-2 in the presence of the Surveyor. TABLE 2 AC Withstand Test System Nominal Voltage 11 KV rms 6.6 KV rms AC withstand test voltage 32 KV rms 20 KV rms Insulation resistance test DC1 KV DC 1 KV Note: The dielectric test is to be performed for 1 minute. 12.2 HV Transformer A transformer is to be tested in accordance with 4-8-5/3.7.5 (e) of the Steel Vessel Rules. A transformer rated 100 kva and above is to be tested in the presence of Surveyor. 12.3 HV Cable Reel Slip Ring 12.3.1 Type Test A slip ring is to be subjected to an AC withstand voltage test in accordance with Table-2 or other relevant national or international standards. The test is to be carried out at the manufacturer s test facility in the presence of the Surveyor. 12.3.2 Onboard Test After installation onboard, the HV switchboard is to be subjected to an insulation resistance test in accordance with Table-2. 12.4 Cable Test After Installation A voltage withstand test is to be carried out in accordance with 4-8-5/3.13.3 of the Steel Vessel Rules in the presence of the Surveyor. 12 ABS GUIDE FOR HIGH VOLTAGE SHORE CONNECTION. 2011