AS/NZS 3000:2007 Amendment 2
|
|
|
- Roy Owens
- 10 years ago
- Views:
Transcription
1 AS/NZS 3000:2007 Amendment 2 Published 14 December 2012 Under Victorian legislation the day a revised standard is published it becomes the requirement. The aim of this document is to highlight the important changes that effects the electrical trade within Victoria, within the amendment there are numerous other changes that are not listed some of those are clerical and printing mistakes, standards that have been upgraded or been replaced. The amendment is available from Standards Australia on Clause applies to Australia only Clause applies to New Zealand only There has been a large increase in New Zealand only clauses. Clause A New Definition Shall Indicates a statement is mandatory Throughout the document a large number of should have been changed to shall making the requirement mandatory. Clause B New Definition Should indicates a recommendation. No impact. Clause Clause Clause Domestic electrical installations (Australia only) domestic electrical installations that meet all of the relevant requirements of AS/NZS 3018 are also deemed to meet Part 1 of this Standard. Protection against switchboard internal arching fault currents. Note 3 Separation of live supply conductors from each other by insulation or barriers in accordance with this Clause is not a requirement of separation, e.g. an IP2X enclosure with bare busbars is acceptable. RCD s - AS/NZS 3003 does not permit a 30 ma RCD to be used upstream of a 10 ma RCD as a leakage protection device in medical treatment areas, as the arrangement does not provide the required discrimination. In Victoria this will only apply when the revised version of AS/NZS 3018 is published, Standards Australia is preparing a draft for comment. The current edition of AS/NZS 3018:2001 does not comply with part 1 of this standard. Supply conductors up to the line side of the protective device(s) within the switchboard shall be provided with means to reduce the probability of initiation of arcing faults by insulation or by separation. Energy Safe Victoria interprets this note to allow the installation of bare busbars, within CT chambers where access is restricted and the arrangement of the busbar and chamber are suitably designed and manufactured to prevent the initiation of an arching fault. Highlights an existing requirement from AS/NZS 3003.
2 Clause Types of RCD s - Revised clause. The existing clause has been replaced and RCD types have been extended and clarified. Clause Additional RCD protection - Residential electrical installations. Smoke detectors have been added and are to be regarded as a lighting point of the purpose of this clause. Clause Exception 2 Clause Clause Clause Clause Clause (a) Additional RCD protection - Other electrical installations. Where an RCD is incorporated into a socket outlet or adjacent to a socket outlet and specifically intended for the protection of that socket outlet the RCD shall interrupt all live (active and neutral) conductors. Alterations, additions and repairs - Where all of the circuit protection on a switchboard is replaced, additional protection by RCDs as required by this Clause 2.6 shall be provided for the final subcircuits supplied from that switchboard Socket-outlets that are added to an existing circuit shall be protected by an RCD. Equipment identification - All equipment installed on a switchboard shall be legibly and indelibly identified in the English language in accordance with the requirements of Clauses to NOTE: See Clauses and for the marking requirements of main switches and additional isolating switches. Identification conductors with green, yellow or green/yellow combination coloured insulation or sheathing shall not be used as active or neutral conductors in installation wiring. Table 3.4 Conductor colours for installation wiring Where colours are used for the identification of cable cores, AS/NZS cable identification colours and European cable identification colours shall not be combined within the same wiring enclosure or the same multi-core cable. Different Installations (a) Common enclosure cable or conductors that form part of different electrical installations shall not be installed within the same wiring enclosure or the same multicore cable. Allows for the RCD to be installed adjacent to the socket outlet. RCD protection is now required when replacing the protective devices, this prevents someone leaving the main switch and neutral bar and upgrading the rest of the switchgear on a switchboard without installing RCD s. Highlights the requirement for all equipment on switchboards to be identified in English and be legible and durable. Prohibits cables with sheathing coloured green, yellow or a combination of green and yellow being installed as installation wiring. Prohibits the installation of cable using European cable identification colours and AS/NZS cable identification colours to be installed in the same wiring enclosure or within the same cable. Prohibits cables from different installations being installed within a multi-core cable or installed in the same wiring enclosure. Page 2 of 15
3 Clause (b) (b) Segregation Where conductors of different domestic or nondomestic portions of an electrical installation that form part of a multiple electrical installation terminate in a common enclosure, they shall be effectively segregated from each other within that enclosure. Clause Table 3.7 minimum separation of underground services Exception 3 Separation distances between conductive enclosures and the earthing electrode are not required where all conductive enclosures are bonded within the installation. Clause (d) Protection of socket-outlets (d) Where installed in a location that is not readily accessible for the connection of a fixed or stationary appliance or a luminaire, the socket-outlet shall be securely fixed to a structure or support to ensure that no mechanical strain is placed on the installation wiring connections when inserting or removing a plug to the socket-outlet. Exceptions: The socket-outlet need not be fixed in position where the installation meets the following conditions: 1. Cable connections are not subject to undue mechanical stress on any connection in accordance with Clause The wiring system, where likely to be disturbed, is supported in accordance with Clause The wiring system, where installed in a suspended ceiling, is supported in accordance with Clause Conductors are flexible or stranded type. 5. Insulated, unsheathed cables, including exposed cores where sheathing is removed, are enclosed in accordance with Clause Prohibits cables supplying different tenancies within a multiple installation being installed in the same wiring enclosures (this requirement need not apply to switchboards where such circuits originate). Removes the segregation requirements between the earth electrode and conductive services (such as a water pipe) where the conductive service is bonded within the installation. Clarifies the requirement for a socket-outlet to be installed in a location that is not readily accessible within the wall behind a range hood or within a suspended ceiling without being fixed where it is arranged so there is no stress on the cable connections and where sheathing is removed and the single insulated conductors are enclosed. Page 3 of 15
4 Clause Clause Recessed luminaires - Lamps near flammable materials Where lamps are located near flammable materials a) lamps shall be suitably shielded by a shade, reflector, guard or enclosure to prevent contact with the material; and b) lamps, such as spotlights, that generate heat in the illuminated surface, shall be separated by such a distance that the material will not attain excessive temperature. Where information is not otherwise provided with products, the minimum separation distances given in Table 4.2 shall be used. Flammable shades shall not be installed where they are liable to come in contact with any lamp. Recessed luminaires - Recessed luminaires and their auxiliary equipment shall be installed in a manner designed to prevent a) excessive temperature rise of the luminaire and auxiliary equipment; and b) the risk of fire from ignition of combustible materials. These requirements shall be satisfied by one of the following compliance methods: (i) The installation of a luminaire designed and certified by the manufacturer as being suitable for operation (A) in contact with combustible materials; or (B) in contact with or enclosed/covered by thermal insulation material. (ii) The installation of a luminaire in combination with a barrier tested and classified in compliance with AS/NZS 5110 as being suitable for the installation conditions. (iii) The installation of a luminaire with separation from thermal insulating materials, combustible building elements and loose combustible materials not less than (A) the minimum clearance specified by the manufacturer of the luminaire, which may require a barrier or guard constructed of fire-resistant materials; or (B) the default clearances as specified in Figure 4.7, which may require a barrier or guard constructed of fire-resistant materials. Highlights the requirements: (a) between the lamp and flammable materials; and (b) the minimum distance between the face of the lamp and the distance the illuminated surface; and clearances where there is no information from the manufacture. The clause has been revised and now relates to all types of recessed luminaires (not just incandescent and halogen). It emphasises that installers must ensure that the installer complies with : (a) the manufacturer s installation instructions; and (b) the luminaire is designed and certified by the manufacturer as being suitable for operation; and (c) the luminaire in combination with a barrier are tested and classified in compliance with AS/NZS 5110 as being suitable for the installation conditions. Note - a luminaire without instructions may not be suitable or designed to be installed within a barrier. The default distances within Figure 4.7 have changed. Page 4 of 15
5 Clause Warning Sign Where recessed luminaires are installed in an accessible roof space, a permanent and legible warning sign shall be installed in the roof space adjacent to the access panel, in a position that is visible to a person entering the space. The sign shall comply with AS 1319 and contain the words shown in Figure 4.8 with a minimum size of lettering of 10 mm. New clause that requires a warning sign to be installed adjacent to the access into ceilings where recessed luminaires are installed. Page 5 of 15
6 Clause Installation precautions (Australia) The following precautions should be undertaken for the installation of recessed downlights: (a) The heat generated from lamps should be dissipated in order to prevent over-temperature damage to the luminaire or to adjacent materials. Cooling air circulation through or around the equipment is a requirement for the typical range of downlights. AS/NZS and AS/NZS detail the test method and the maximum surface temperatures permitted for recessed luminaires. The maximum temperature of adjacent materials is to be no more than 90 C. (b) In the case of a suitably designed and certified luminaire (compliance method (i)), the manufacturer s instructions may restrict installation including warnings such as covering with insulation or the following AS/NZS symbol meaning Do Not Cover. New clause providing precautions need to be undertaken for the installation of recessed downlights: Incorporating instructions from manufacturers and the Building Code of Australia. However, for typical fittings, the installation method will be to provide barriers (compliance method (ii)) or clearances (compliance method (iii)) during installation, so as to prevent contact with materials that may impede air flow (e.g. thermal insulation) or that may be affected by the high temperature (e.g. combustible building elements). Unmarked light fittings shall be treated as Do Not Cover. (c) Under National Building Code requirements, bulk thermal insulation is prevalent in modern building construction within roofs, ceilings, walls and floors depending on the type of building and its climate zone. Page 6 of 15
7 Clause continue Bulk thermal insulation may also be retrofitted, added or altered in which case precautions will need to be applied by the insulation installer, where recessed downlights are present, or the luminaire installer, where insulation is present. In Australia AS 3999 include instructions for insulation installers in relation to clearances from recessed downlights and other types of electrical equipment that may be adversely affected by lack of cooling air circulation. (d) The presence of bulk thermal insulation, particularly over the rear of a ceiling mounted downlight, can readily impair cooling air circulation. Unless the luminaire manufacturer specifies otherwise (compliance method (i)) or the barrier is classified to permit insulation coverage (compliance method (ii)), the space above the luminaire, shown as dimension A of Figure 4.7, shall remain clear and a warning sign as shown in Figure 4.8 shall be installed. (e) Where clearances are to be applied (compliance method (iii)) and bulk thermal insulation is not fixed in position, one of the following means shall be provided and secured in position to maintain the clearances: (i) A barrier complying with AS/NZS (ii) A guard complying with AS (f) (iii) A barrier or guard constructed of fire-resistant materials. Combustible materials should be prevented from being in close proximity or contacting hot surfaces of the luminaires. This includes structural timber which may be affected by pyrolysis which over a long exposure can result in increased susceptibility to ignition. Where extraneous material, such as leaves, vermin debris or combustible materials stored in a roof space, are present in proximity to the downlight, the precautions shall include the use of a suitably designed and certified luminaire (compliance method (i)) or a barrier (compliance method (ii)). (g) Unless the auxiliary equipment instructions permit otherwise, any auxiliary equipment operating at a high temperature shall be installed above any insulation as illustrated in Figure 4.7. Page 7 of 15
8 Clause Stationary cooking appliance - A circuit for a fixed or stationary cooking appliance having an open cooking surface incorporating electric heating, e.g. cooktops, deep fat fryer, barbecue griddle, or similar, shall be provided with a switch, operating in all active conductors, mounted near the appliance in a visible and readily accessible position. Switches shall be marked to identify the appliance controlled. Revised Clause that now includes induction and ceramic cooktops as an open cooking surface incorporating electric heating. Existing requirements from the gas standard has been included. Clause Where the open cooking surface is a combined gas/electric appliance incorporating both gas and electric cooking, the switching device shall operate in all live (active and neutral) conductors. Gas appliances A gas appliance connected to the electricity supply shall be provided with a means of electrical isolation that is adjacent to the appliance location and is accessible with the appliance in the installed position. The means of isolation shall be (a) (b) a plug to a switched socket-outlet; or a plug to a socket-outlet that may be located in an inaccessible position but has a separate switch operating in all live (active and neutral) conductors located in an accessible position; or (c) a switch operating in all live (active and neutral) conductors. NOTE: If the appliance has an open cooking surface incorporating both gas and electric cooking, it shall also comply with Clause 4.7. New Clause highlighting the existing requirements from the gas standard. Page 8 of 15
9 Clause Gas cylinders containing heavier-than-air gases outdoors Electrical equipment that is a source of ignition, such as socketoutlets, switches, luminaires, switchboards, meter boxes and airconditioners, shall not be installed within the hazardous areas shown in Figure 4.10 by dimensions A and B. Dimensions A and B are shown in Figure 4.10 for both exchange and in-situ fill gas cylinders. For further information, refer to AS/NZS and AS/NZS 5601 particularly for gases lighter than air. Exception: Approved combined gas and electrical meter enclosures are exempted from these requirements. NOTE: Electrical equipment selected and installed in accordance with Clause is not considered an ignition source. Clause 4.19 Air-condition and heat pump systems - Air-conditioning and heat pump systems incorporating a compressor shall be provided with a lockable isolating switch installed adjacent to the unit, which isolates all parts of the system including ancillary equipment, from the same location. For split system air-conditioning units, where the manufacturer requires the air-conditioning system to be connected to the electricity supply by means of a plug and socket at the internal unit, the isolating switch installed at the external unit shall control the socket-outlet located at the internal unit. Exception: The isolating switch may be installed at the switchboard supplying the system if the switchboard is dedicated to the equipment (e.g. an air-conditioning plant room). New Clause highlighting the existing requirements from the gas standard. New clause in Victoria this has been a requirement since 2009 the significant change is that the isolating switch can only be installed adjacent to the unit containing the compressor. It now also requires an isolating switch to be installed adjacent to the unit containing the compressor where the supply is connected by means of plug and socket at the internal unit. Page 9 of 15
10 Clause Clause Variable frequency devices Devices that produce high frequency currents in the protective earth may produce touch voltages that are dangerous to persons and livestock. NOTES: 1 The touch voltages may be as much as a 100 V but the manufacturer s advice should be sought when installing this type of device. These high frequency voltages may not be detectable using normal 50 Hz test instruments. An oscilloscope and ballast resistor should be used. 2 Attention is drawn to the safety requirements for electronic equipment in AS Conductive pool structures Where the pool structure is conductive, all extraneous conductive parts, including the reinforcing metal of the pool shell or deck, shall be connected to an equipotential bonding connection point complying with Clause Where any of the items described in Clause are required to be equipotentially bonded, the bonding shall be extended to the conductive pool structure by means of the equipotential bonding connection point. New Clause highlighting the dangers involved in high frequency devices. New clause requiring pool structures with reinforcing metal of the pool shell or deck to be connected to equipotential bonding connection point. Page 10 of 15
11 Clause Clause Equipotential bonding conductor connection point A connection point shall be provided at the swimming or spa pool location for the bonding connection to be made to the conductive parts of the pool structure. Where equipotential bonding is required, the connection point may also be used as a common point for the connection of other conductive fixtures and fittings to the bonding arrangement. The connection point shall be (a) located in a position that will be accessible with space for connections to be made after pool construction (for example, a pit located adjacent to the pool equipment); (b) identified by marking of the location on the switchboard at which the circuits supplying the pool or spa originate, or other permanent location; (c) of suitable design and construction in accordance with Clause 3.7; (d) protected against mechanical damage in accordance with Clause ; and (e) protected against corrosion in accordance with Clause The particular requirements of this Clause 7.2 apply to the electrical installation of building services that are essential for the safe operation of the safety services consisting of fire detection, warning and extinguishing systems, smoke control systems, evacuation systems and the safety of persons using lifts. The requirements are intended to ensure that electricity supply is not inadvertently disconnected from electrical equipment that is required to operate during emergency conditions. New clause requiring the establishment of a connection point in a pit or similar arrangement near the pool equipment for the connection or future connection of equipotential bonding. The location shall be marked in the switchboard where there was no alternative supply has been deleted from the end of the sentence. Page 11 of 15
12 Clause Lifts For the purposes of this Clause 7.2, lifts shall be deemed to include electrically controlled lifts that may convey persons, but do not include any conveying device from which passengers may safely alight should the apparatus stop at any point in its travel (for example escalators). Exceptions: 1 The electricity supply for a passenger lift that allows passengers to alight safely in the event of a loss of electricity supply need not be arranged as a safety service (for example, hydraulic or other lifts incorporating means for evacuation to a floor level). 2 A lift in a single private residence that is installed in accordance with AS/NZS need not comply with the requirements of this Clause 7.2. NOTE: Although compliance with the AS 1735 series is not a requirement of this Standard; regulatory authorities may require compliance and may have additional requirements. Revised clause In Victoria the definition of lift in AS/NZS 3000:2007 has the same meaning as passenger lift within the Electricity Safety (Installations) Regulations This means that the lift installation including the supply, control and protection is a prescribed electrical installation and is required to be inspected by a licensed electrical inspector before connection or when altered. For reference - Regulation 238(i) of the Victorian Electricity Safety (Installations) Regulations Prescribed electrical installation work - circuit protective devices, switchgear, controlgear, wiring systems and accessories (other than fire detection and alarm systems) installed to provide control and protection of passenger lifts, fire pumps (excluding pumps for fire hose reels where those hose reels are not the sole means of fire protection) and air handling systems intended to exhaust and control the spread of fire and smoke; Clause Electricity generation systems The selection, installation and control of electrical equipment that is intended to form an electricity system shall comply with the following Standards: (a) Engine-driven generating sets AS/NZS 3010 (b) Stand-alone power systems AS 4509 (series) (c) Battery systems AS 3011 (d) Photovoltaic array systems AS/NZS 5033 (e) Grid connected inverter systems AS 4777 (series) And Regulation 239 of the Electricity Safety (Installations) Regulations 2009 requires Prescribed electrical installation work to be inspected by a Licensed Electrical Inspector within 8 working days after the completion of that work. Grid connected inverter systems AS 4777 (series) has been added as a requirement. Page 12 of 15
13 Clause Clause Clause Clause 8.4 Grid-connected inverter systems The generation system shall not impose a voltage on the installation at the network point of supply outside the limits specified by Clause 1.6.2(c). Hazardous areas Responsibility for classification The responsibility for classification of a hazardous area rests with the persons or parties in control of the installation. The requirements are contained in AS/NZS for gas or vapour and AS/NZS for combustible dust. Verification Testing (c) all Edison screw lampholders that are not incorporated in an appliance or provided with a shroud or skirt that prevents contact with the outer contact shall have the neutral connected to the outer contact; and (d) all fixed socket-outlets for multiphase supplies shall be connected so the phase sequence is the same throughout the installation. Initial energization or certification date The date of initial or certification of an installation should be available on-site, either by marking or in an accessible record. Additional requirement and Figure 7.5 has been modified including additional notes. Updated to reflect new standards. Additional requirements. The date certified has been added Page 13 of 15
14 Appendix A Normative References 4509 Stand-alone power systems Part 1: Safety requirements Part 2: System design 5110 Recessed luminaire barriers 5601 Gas installations 7000 Overhead line design Detailed procedures 60079(Ser) Explosive atmospheres Part 10.1: Classification of areas Explosive gas atmospheres Part 10.2: Classification of areas Combustible dust atmospheres Part 14: Electrical installations design, selection and erection Part 17: Electrical installations inspection and maintenance Household and similar electrical appliances There is a number of new standards, some replace obsolete standards. There are also existing standards that have changed status from informative (advisory only) to normative (mandatory) Part 2.41 Safety Particular requirements for pumps Part 2.76: Safety Particular requirements for electric fence energizers (IEC , Ed. 2.0 (2002) MOD) Low-voltage switchgear and controlgear Part 3: Switches, disconnectors, switch-disconnectors and fuse-combination units Page 14 of 15
15 Appendix E Scope This Standard (AS/NZS 3000) contains provisions relating to the protection of an electrical installation from fire and electric shock, which are dependent on, or incorporated in, building requirements. Thus, reference to National Building Codes is recommended for clarification of the application and any exceptions. National Building Codes also contain a number of other provisions which relate to the design, selection and installation of equipment that forms part of an electrical installation, and which are intended to satisfy objectives for health, amenity, sustainability and energy efficiency. The whole appendix has been updated and replaced. With updates and changes in E2.2.2 Fire Safety and E2.2.4 Sustainability and energy efficiency providing requirements. Page 15 of 15
NZECP 14: 1995 ISSN 0114-0663 COVER PAGE
NZECP 14: 1995 ISSN 0114-0663 COVER PAGE NZECP 14:1995 NEW ZEALAND ELECTRICAL CODE OF PRACTICE FOR CONTROL PROTECTION AND SWITCHBOARDS Issued by the Office of The Chief Electrical Engineer, Energy and
Trial Exams C. Standards and Regulations. Examination No: GH-08-C- 1 hour and 5 minutes plus 10 minutes reading time
Trial Exams C Standards and Regulations Examination No: GH-08-C- This test is intended to gauge your knowledge of essential information contained within AS/CA S009:2013. To qualify for an allpication to
Listed are common requirements that apply to existing solar installations when altered, added to or reconfigured.
SOLAR ALTERATIONS REQUIREMENTS August 2015 These requirements address typical alterations to solar installations; they cannot address every scenario. In Victoria, an alteration to a solar installation
Electrical Practices for Construction Work
1. Purpose Electrical Practices for Construction Work The purpose of this Code is to provide practical guidance and set minimum safety requirements for electrical practices on all construction sites in
CHECKING AND TESTING ELECTRICAL INSTALLING WORK
CHECKING AND TESTING ELECTRICAL INSTALLING WORK Department of Consumer and Employment Protection Energy Safety Preface It is a requirement of the Electricity (Licensing) Regulations 1991 that all electrical
ELECTRICAL PRACTICES FOR CONSTRUCTION WORK
CONTRACTOR S CHECKLIST ELECTRICAL PRACTICES FOR CONSTRUCTION WORK 2007 WorkCover. Watching out for you. New South Wales Government Disclaimer This publication contains information regarding occupational
12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting
12 SOLAR PHOTOVOLTAIC POWER by John Ware IT IS PLANNED for BS 7671:2008 to include a new Section 712 providing additional requirements for safety applicable to solar photovoltaic (pv) power supply systems.
DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE CONSTRUCTION SAFETY STANDARDS
MIOSHA-STD-1313 (10/15) 6 Pages For further information Ph: 517-284-7740 www.michigan.gov/mioshastandards DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE CONSTRUCTION SAFETY STANDARDS
Unified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to
STANDARDS AUSTRALIA/STANDARDS NEW ZEALAND
AS/NZS 3000/Amdt 1/-07-30 STANDARDS AUSTRALIA/STANDARDS NEW ZEALAND Amendment to AS/NZS 3000:2007 Electrical installations (known as the Australian/New Zealand Wiring Rules) REVISED TEXT The 2007 edition
Top Commercial / Residential Electrical Requirements *
Department of Community Development Building Division 4800 West 92 nd Avenue Westminster, Colorado 80031 For Information call (303) 658-2075 Fax (303) 706-3922 www.westminsterpermits.com Top Commercial
DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)
DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations) DETAILS OF THE CLEINT Client and address ADDRESS OF THE INSTALLATION Installation
Heading FACT SHEET. Overview. www.safeworkaustralia.gov.au
ELECTRICAL RISKS AT THE WORKPLACE Heading FACT SHEET Overview This fact sheet provides general guidance for persons conducting a business or undertaking (PCBUs) and workers on managing electrical risks
FREQUENTLY ASKED QUESTIONS
September 2011 FREQUENTLY ASKED QUESTIONS Wiring Rules The new edition of the Australian/New Zealand Standard for Wiring Rules (AS/NZS 3000:2007) was released in November 2007 and revised by Amendment
City of Riverside Building & Safety Division Phone: (951) 826-5697 www.riversideca.gov
City of Riverside Building & Safety Division Phone: (951) 826-5697 www.riversideca.gov PHOTOVOLTAIC PERMITTING GUIDELINES The information provided in this document is general and is intended only as a
chapter8 Testing and commissioning Unit 2 outcome 2
Testing and commissioning chapter8 Unit 2 outcome 2 It is important that electricians are not just able to construct; they should also be able to recognise faults and take action to help prevent them.
INFRARED QUARTZ WALL HEATER
INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this
GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL 34471 (352) 629-8421; FAX: (352) 629-8264
BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS Building Code compliance is the obligation of design professionals and/or contractors. Plan Review and Inspection Guidelines are intended to be used
MEM10019 Select circuit protection devices by type and rating, fit to switchboards and install earthing
MEM10019 Select circuit protection devices by type and rating, fit to switchboards and install earthing Release: 1 MEM10019 Select circuit protection devices by type and rating, fit to switchboards and
MISCELLANEOUS ELECTRICAL JOBS REQUIRING PERMITS
MISCELLANEOUS ELECTRICAL JOBS REQUIRING PERMITS 01. SAFETY INSPECTION of service equipment at FPL Power Source 02. Construction GFI power outlets (Temp Pole for Construction) 03. 90 day temporary power
2012 Canadian Electrical Code, Part I (CEC) Top Fifteen changes
2012 Canadian Electrical Code, Part I (CEC) Top Fifteen changes 1) Tamper resistant receptacles. 2009 CEC Required in dwelling units 2012 CEC Expanded to child care facilities First introduced in the 2009
Union County Public Schools. Facilities Department. Electrical. Safe Work Practices
1 Union County Public Schools Facilities Department Electrical Safe Work Practices 2 Purpose In accordance with OSHA Standards 1910.331-335, safety-related work practices shall be used by Union County
Electrical safety and you
Electrical safety and you A brief guide Introduction Electricity can kill or severely injure people and cause damage to property. Every year many accidents at work involving electric shock or burns are
ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST
Name of School: OPTIONAL INFORMATION Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST Guidelines: This checklist
ELECTRICAL INSTALLATION CONDITION REPORT (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)
Original Certificate DETAILS OF THE CLIENT Certificate reference: ELECTRICAL INSTALLATION CONDITION REPORT (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations) Name: Address: PURPOSE
Article 10 - ADMINISTRATIVE SECTION
Article 10 - ADMINISTRATIVE SECTION 10.1 TITLE These Administrative Regulations along with the requirements included in the 2011 Edition of the National Electrical Code (NFiPA-70-2011) as adopted by the
SAFETY ALERT SWITCHBOARD INTERNAL SEGREGATION AND IP RATING. May 2014 BACKGROUND
SAFETY ALERT SWITCHBOARD INTERNAL SEGREGATION AND IP RATING May 2014 BACKGROUND There has been a recent serious incident involving a large arc event caused by material falling through an opening in a switchboard
Electrical Resistance Resistance (R)
Electrical Resistance Resistance (R) Any device in a circuit which converts electrical energy into some other form impedes the current. The device which converts electrical energy to heat energy is termed
Changes to the Electricity (Safety) Regulations effective from 1 July 2013. www.energysafety.govt.nz www.ewrb.govt.nz www.standards.co.
Changes to the Electricity (Safety) Regulations effective from 1 July 2013 www.energysafety.govt.nz www.ewrb.govt.nz www.standards.co.nz Changes to the electrical certification regime under the Electricity
Fire Protection Notice No. 9 ELECTRICAL SAFETY
Fire Protection Notice No. 9 ELECTRICAL SAFETY Because electricity is one of the most controllable forms of energy it can also be one of the safest. But, as industry and commerce draw ever more heavily
PROTECTION AGAINST ELECTRIC SHOCK by John Ware
16 become live under fault conditions. The potential of the metal enclosure is higher than that of the main earthing terminal of the installation (and that of Earth) because of a potential difference created
AIR-CONDITIONER SPLIT TYPE
FILE NO. A08-016 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE RAS-M10PKVP-E, RAS-M13PKVP-E, RAS-M16PKVP-E, RAS-M18PKVP-E / RAS-M10PKVP-ND, RAS-M13PKVP-ND, RAS-M16PKVP-ND, RAS-M18PKVP-ND / RAS-3M26GAV-E1,
Australian/New Zealand Standard
Australian/New Zealand Standard The use of ventilation and air conditioning in buildings - Part 1: Fire and smoke control in buildings UPDATED AS/NZS 1668.1:2015 What is the scope of this Standard? The
INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1
City of Cotati Building Division 201 W. Sierra Ave. Cotati, CA 94931 707 665-3637 Fax 792-4604 INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1 Any PV system on a new structures should be included
1 Introduction. 2 Hazards From Electricity
Risk Assessment Application to Electrical Rigs A guide to assist the Competent Named person who will verify the safety of rigs consisting mainly of electrical equipment. 1 Introduction Every employer shall
Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide
Instruction Bulletin EAV85226 08/2014 Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide Retain for future use. Product Description Kit Contents The Wiser Panel Meter is for use in energy management
6.0 Electrical Installations
6.0 An electrical installation is a combination of electrical equipment installed to fulfill a specific purpose and having coordinated characteristics. In dealing with the electrical installation, it is
FAQs-Main switchboard design criteria
FAQs-Main switchboard design criteria Q: What is the Australian standard for main switchboards? Current Australian standard is AS/NZS 3439.1: 2002 originating from IEC 60439. The new series of standard
Electrical Safety Tips. Help us keep you safe
Electrical Safety Tips Help us keep you safe To help you stay safe when using electricity, ActewAGL has compiled these electrical safety tips. For natural gas safety tips please see ActewAGL s natural
GUIDE TO THE MAINTENANCE, INSPECTION AND TESTING OF PORTABLE EQUIPMENT (ELECTRICAL APPLIANCES AND TOOLS) IN THE WORKPLACE
GUIDE TO THE MAINTENANCE, INSPECTION AND TESTING OF PORTABLE EQUIPMENT (ELECTRICAL APPLIANCES AND TOOLS) IN THE WORKPLACE ET 215:2008 ELECTRO-TECHNICAL COUNCIL OF IRELAND 2008 Page 1 of 6 Published by
ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:
ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: Chapter 12 of the Burlington Code of ordinances allows owner occupants of single family homes to do their own wiring if they choose. If you choose to
ELECTRICAL SAFETY. The standard unit for measuring electrical current.
ELECTRICAL SAFETY Introduction The following sections provide general safety guidelines and procedures for electrical safety. This chapter covers the following topics: TOPIC PAGE General Electrical Safety
LightingEurope EU Compliant Requirements Products Sheets for LIGHTING COMPONENTS
LightingEurope EU Compliant Requirements Products Sheets for LIGHTING COMPONENTS 1 st Edition 29 th November 2013 Table of content a. Disclaimer... 3 b. Introduction... 3 c. Summary check lists for components...
Regulations for the Installation of Electrical Wiring, Electrical Equipment and Air Conditioning Equipment
Regulations for the Installation of Electrical Wiring, Electrical Equipment and Air Conditioning Equipment Qatar General Electricity & Water Corporation KAHRAMAA Customer Services Department State of Qatar
Proposed changes to the Acceptable Solution for Building Code clause F7 (Warning Systems) Proposed amended Acceptable Solution for Warning Systems
Proposed changes to the Acceptable Solution for Building Code clause F7 (Warning Systems) Appendix A Proposed amended Acceptable Solution for Warning Systems s in the grey boxes form part of the proposed
This Guideline does not address electrical equipment in the following categories:
Policy Hierarchy link Responsible Officer Contact Officer Superseded Documents HS418 Portable Electrical Equipment Inspection, Testing and Tagging Guideline Work Health and Safety Act 2011 Work Health
USER S MANUAL. MaxPower 400-600 UPS. Uninterruptible Power System 28-2MAXPO0018
USER S MANUAL MaxPower 400-600 UPS Uninterruptible Power System 28-2MAXPO0018 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for models MaxPower 400 and
INTERNATIONAL STANDARD
IEC 61892-7 INTERNATIONAL STANDARD Edition 2.0 2007-11 Mobile and fixed offshore units Electrical installations Part 7: Hazardous areas INTERNATIONAL ELECTROTECHNICAL COMMISSION PRICE CODE XA ICS 47.020.60
County of Riverside Building and Safety Department
County of Riverside Building and Safety Department Mike Lara Director Photovoltaic Permitting Guidelines The information provided in this document is general and is intended only as a guide. Each project
CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel
CHAPTER 4 UTILITY SYSTEMS ELECTRICAL Utility Systems Electrical The electrical supply to your home begins outside, where you will see either an overhead feed and piping down the side of your home or (if
EARTHING AND BONDING AT SECONDARY SUBSTATIONS
DISTRIBUTION CONSTRUCTION MANUAL SECTION 4 - SUBSTATIONS ISSUE B SEPT 1996 4.4.4 EARTHING AND BONDING AT SECONDARY SUBSTATIONS 1 SCOPE This section of the Distribution Construction Manual lays down the
Solar Panel Installations
Solar Panel Installations Page 1 of 6 SINGLE-FAMILY RESIDENTIAL CHECKLIST City of Hayward Development Services Department Revised: 7-09-15 PERMIT REQUIREMENTS Permits are required for all solar panel installations.
Instructions for Safe Use
Instructions for Safe Use (Certification N:o VTT 08 ATEX 029) Thank you for choosing Slam Trans portable transformer for your job site. Purpose of this manual is to provide you all the necessary safety
ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV
1. SCOPE This document details PowerSystems requirements for electrical testing of HV Equipment up to and including 33kV. 2. ISSUE RECORD This is a Reference document. The current version of Controlled
6 June 2014. Document Status REVISION STATUS DATE. Initial release to industry. This Revision expired on 16 Sep. 2013.
6 June 2014 Document Status REVISION STATUS DATE REV 0 Initial release to industry. This Revision expired on 16 Sep. 2013 6 Sep 2013 REV 1 Draft submission to ESDD 16 Sep 2013 REV 2 Draft resubmission
ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR 1910.252 WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600
OSHA REGULATION: 9 CFR 90.5 WELDING, CUTTING, AND BRAZING ( HOT WORK ) A. POLICY. This procedure follows requirements set forth in 9 CFR 90.5.. This policy applies to all Hot Work operations being done
Guide to the Safety, Health and Welfare at Work (General Application) Regulations 2007. Part 3: Electricity
Guide to the Safety, Health and Welfare at Work (General Application) Regulations 2007 Part 3: Electricity 9 Guide to the Safety, Health and Welfare at Work (General Application) Regulations 2007 Part
Electrical safety of grid-connected solar installations in Western Australia December 2011
Electrical safety of grid-connected solar installations in Western Australia December 2011 Level 1, 303 Sevenoaks Street (cnr Grose Avenue) Cannington, Western Australia 6107 PO Box 135 Cannington WA 6987
Significant Changes in the 2011 NEC Prepared by Bryan Holland City of North Port
Significant Changes in the 2011 NEC Prepared by Bryan Holland City of North Port Code-Wide Code Change Section 90.5(C). Fine Print Notes are now referred to as "Informational Notes." The purpose, intent,
Ontario Electrical Safety Code 25 th Edition/ 2012
Ontario Electrical Safety Code 25 th Edition/ 2012 Ted Olechna Director, Codes and Standard Chief Engineer 1 What I Will Cover ESA s role is as the regulator Highlight of 2012 Code changes The Code and
Electrical installation condition reporting:
Electrical installation condition reporting: Classification Codes for domestic and similar electrical installations FUSED 4 Issue 3 This is one of a series of Best Practice Guides produced by the Electrical
Technical Data. Dimensions
0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female
Compliance Document for New Zealand Building Code Clause F7 Warning Systems Fourth Edition
Compliance Document for New Zealand Building Code Clause F7 Warning Systems Fourth Edition Prepared by the Department of Building and Housing This Compliance Document is prepared by the Department of Building
Installation Instructions for Alarm Module Kit A043F059
Instruction Sheet 07-2013 Installation Instructions for Alarm Module Kit A043F059 1 Introduction The information contained within is based on information available at the time of going to print. In line
RCD Inspection Log Book
RCD Inspection Log Book This book is the property of: Commenced: / /. Completed: / /. 2 Clipsal Australia Pty Ltd Clipsal Australia Pty Ltd 3 4 Clipsal Australia Pty Ltd Clipsal Australia Pty Ltd 5 6 Clipsal
Electrical Equipment in Hazardous Areas: Field Inspections
Electrical Equipment in Hazardous Areas: Field Inspections Bill Rankin Electrical Engineer / Senior Electrical Inspector Abstract Electrical equipment and installations that fall within explosive gas atmospheres
Work in Substations - General
Work in Substations - General Summary: This document supports the Power System Safety Rules and its requirements assembled under Work in Substations General Category 3 and apply to all persons working
Utilities and existing services
Construction Services Building standards for mechanical and electrical installations Utilities and existing services October 2012 Directorate: Environment Construction Services - Building standards for
Electrical installations on construction sites
Industry standard Electrical installations on construction sites Edition No. 3 January 2011 The information presented in the Industry Standard Electrical installations on construction sites is intended
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
Safe Operating Procedure
Safe Operating Procedure (Revised 07/09) HOT WORK PERMIT OPERATIONS (For assistance, please contact EHS at (402) 472-4925, or visit our web site at http://ehs.unl.edu/) Authority In recognition of the
ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU
ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU George CURCANU, Constantin ILINCA, Ilie SBORA ICMET Craiova, Romania, Calea Bucuresti 144, phone:
INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE SAFETY BULLETIN #23
INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE SAFETY BULLETIN #23 GUIDELINES FOR WORKING WITH PORTABLE POWER DISTRIBUTION SYSTEMS AND OTHER ELECTRICAL EQUIPMENT "ADDENDUM C" WORKING WITH 480 VOLT SYSTEMS
HOT WORK PERMIT PROGRAM TRAINING. John Braun
HOT WORK PERMIT PROGRAM TRAINING John Braun 1.0 INTRODUCTION 1.2 Purpose The Hot Work Permit Program has been developed for University employees that work on or around hot work activities. This program
Report for. Dick and Jane Homeowner. 1234 Lovers Lane, Houston, Texas 77000
Report for Dick and Jane Homeowner 1234 Lovers Lane, Houston, Texas 77000 March 17, 2004 I NI NP R Inspection Item I. STRUCTURAL SYSTEMS o o o A. Foundations (If all crawl space areas are not inspected,
WORKING IN CONFINED SPACES GUIDELINES
WORKING IN CONFINED SPACES GUIDELINES Contents 1 Introduction... 2 2 Scope... 2 3 Definitions... 2 4 Responsibilities... 3 4.1 Permit Authoriser... 3 4.2 Permit Receiver... 3 4.3 Responsible UOW Officer...
SITE CONTRACTOR PROCEDURES
SITE CONTRACTOR PROCEDURES Asset Collection Type B Assets are considered High risk ; the site activities must be in accordance with Graysonline contractor procedures and are to be collected by appointment
Dennis Fire Department Fire Prevention Mark Dellner Fire Chief
Dennis Fire Department Fire Prevention Mark Dellner Fire Chief FIRE SAFETY INSPECTION GUIDELINES FOR COMMERCIAL PROPERTIES (MA Fire Prevention Regulations 527 CMR, MGL Chapter 148) FIRE PREVENTION CHECKLIST-
Questions and Answers for Heating and A/C Contractors
1. How do we accomplish grounding of furnaces and / or water heaters on two wire circuits? 250.134 Equipment Fastened in Place or Connected by Permanent Wiring Methods (Fixed) Grounding. Unless grounded
David O Brien, CMP Products ([email protected])
David O Brien, CMP Products ([email protected]) 1) Main Function of Cable Glands 2) Common Issues with Cable Glands 3) Compliance / Standards, changing times 4) How do we select Cable Glands?
Circuit Electrical Testing
Safe Isolation Procedure Circuit Electrical Testing Site Safety Management It is essential from the outset that effective management and control of the system, apparatus and equipment used on site is achieved
Earthing Guidance Notes
Central Networks Earthing Manual Section E2 Earthing Guidance Notes Version: 2 Date of Issue: September 2007 Author: Nigel Johnson Job Title: Earthing Specialist Approver: John Simpson Job Title: Head
FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10
TECHNICAL SPECIFICATIONS Page 1 of 10 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC conventional, electrically supervised, zone annunciated, fire detection and alarm system as specified
PLEASE NOTE. For more information concerning the history of these regulations, please see the Table of Regulations.
PLEASE NOTE This document, prepared by the Legislative Counsel Office, is an office consolidation of this regulation, current to August 1, 2013. It is intended for information and reference purposes only.
Practice Note 2014-62
Practice Note 2014-62 Documentation Required for Applications for Building Permits Reference to the Building Code of Australia (BCA) in this Practice Note means Volume One and Volume Two of the National
IMPORTANT SAFETY NOTICE
IMPORTANT SAFETY NOTICE To: Our Valued Customers User safety is a major focus in the design of our products. Following the precautions outlined in this manual will minimize your risk of injury. ITT Goulds
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook Trainee:... Training Provider:... Year:... Trainee Contact no:... Competency Based Skill Training Logbook Introduction
SELECTION OF FINAL CIRCUIT PROTECTION
SELECTION OF FINAL CIRCUIT PROTECTION By Phil Williams, Product Marketing Manager, Power Distribution Components, Eaton Executive summary The selection of devices for final circuit protection in electrical
STATE OF FLORIDA HOME INSPECTION STANDARDS OF PRACTICE:
STATE OF FLORIDA HOME INSPECTION STANDARDS OF PRACTICE: 61-30.801 Standards of Practice, General. (1) Home inspections performed to these Standards of Practice are intended to provide the client with information
Application Form for Self Storage Insurance
Note: The information contained in this report is provided by the broker for preliminary risk assessment only. A full survey, if required, will need to be carried out by the insurer. Client Details Full
2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE
2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE PAGE 1 OF 5 This Reference provides a very comprehensive list of aspects of a solar PV installation that could be reviewed, clarifying
Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE
Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE To: Our Valued Customers User safety is a major focus in the design of our products. Following the precautions outlined in this manual will
HAZARDS, INCLUDING SHOCK, ARC FLASH AND FIRE
Appendix B-2 - Electrical Safety In Design Final Report TECHNOLOGIES THAT REDUCE LIKELIHOOD OF INJURY FROM ELECTRICAL HAZARDS, INCLUDING SHOCK, ARC FLASH AND FIRE The following are technologies that reduce
Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems
Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems If you're a designer or a BCA, this guidance on the energy efficiency of HVAC systems in commercial buildings may
CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES
CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES Review the following information pertaining to Construction Fire Safety Planning: B.C. Building Code Sections 8.1 up to and including Subsection 8.2.3 B.C.
Site and Storage Conditions for Class 3.1 Flammable Liquids
Site and Storage Conditions for Class 3.1 Flammable Liquids Introduction Contents Introduction... 1 SITE AND STORAGE CONDITIONS...2 Part 1 General Flammability Conditions...2 Part 2 Conditions Relating
Common Electrical Hazards in the Workplace Including Arc Flash. Presented by Ken Cohen, PhD, PE & CIH (Ret.)
Common Electrical Hazards in the Workplace Including Arc Flash Presented by Ken Cohen, PhD, PE & CIH (Ret.) 1 What s New In February 1972, OSHA incorporated the 1971 edition of the National Fire Protection
Switchgear and Metal-Enclosed Bus
Section 18 Switchgear and Metal-Enclosed Bus 180. SWITCHGEAR ASSEMBLIES 180A. General Requirements for All Switchgear. This rule covers general requirements for all switchgear. Examples of switchgear found