Engineers Edge, LLC PDH & Professional Training

Similar documents
Engineers Edge, LLC PDH & Professional Training

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Element D Services Electrical

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Sample - No Commercial Use

Power Management Module 2. Installation

Electrical. This section applies to the design and installation of building power distribution systems.

Secondary Unit Substations

Switchgear and Metal-Enclosed Bus

Short Circuit Current Calculations

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Section 9: Power Distribution Equipment Bill Brown, P.E., Square D Engineering Services

Specification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

Mini Power-Zone Unit Substation

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

CHAPTER 2 EXAMPLES AND TABLES

Introduction. Upon completion of Basics of Switchboards you should be able to: Explain the role of switchboards in a distribution system

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

How To Test A Power Switch On A Power Supply

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

Cable/Conduit Conversion

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

Primary and Secondary Electrical Distribution Systems

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

Fusible Disconnect Switch

Power-Zone 4 Arc Resistant Low Voltage Switchgear

Engineers Edge, LLC PDH & Professional Training

MCC Ratings. Voltage Rating

COMPARISON OF ANSI/IEEE AND IEC REQUIREMENTS FOR LOW- VOLTAGE SWITCHGEAR

Integrating SPDs in Switchgear & Switchboards Causes More Problems than it Solves

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

3. TYPES OF SERVICE AVAILABLE. 3.1 Scope

Grounding Practice at Data and Communications Centers. David Brender, P.E., CPQ National Program Manager Copper Development Association Inc.

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

This section applies to the design and installation of transformers.

Guidelines on the Short Circuit Current Rating for Industrial Control Panels

101 BASICS SERIES LEARNING MODULE 3: FUNDAMENTALS OF ELECTRICAL DISTRIBUTION. Cutler-Hammer

Masterclad Medium Voltage Passive Arc-Resistant Switchgear

Low Voltage Transformer Through-Fault Protection: A System Approach

SECTION MEDIUM VOLTAGE SWITCHGEAR

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Commercial/Industrial Electricity

Unit substation solutions with type SIMOSEC primary switches quick reference guide E50001-F710-A389-X-4A00. Answers for energy.

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

SECTION SWITCHBOARDS

MONTGOMERY COUNTY EXECUTIVE REGULATION Offices of the County Executive. 101 Monroe Street. Rockville, Maryland 20850

Zenith Series MDU & RDU. Critical Power Distribution Units

INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1

Evaluating Water-Damaged Electrical Equipment

Bold items are particular to the City of Euless

UL 508A Industrial Control Panels Power Distribution and Control. Lunch & Learn Training Eaton Corporation. All rights reserved.

Siemens STEP 2000 Course Basics of Electrical Products

Customer Low-Voltage Switchboards Service Cable Terminal Compartment Arrangements and Clearances

Evaluating Water-Damaged Electrical Equipment

Evaluating Water-Damaged Electrical Equipment

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

East Central College HANSEN HALL LEVEL 300/400 RENOVATIONS PACKAGE

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC INTEGRATED SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671A SECTION 16671A

Buck - Boost Transformers

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

Addendum #2 Contract UK-11-13

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.

INDUSTRIAL AND COMMERCIAL SERVICE TRANSFORMER & METERING INSTALLATION SPECIFICATION

Part 1 System Modeling & Studies for Existing Systems

SURGE PROTECTIVE DEVICES

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

Occupancy: Assembly (A-3) and Business -Includes offices, seminar rooms, classrooms, and café facility. Duke University Medical School

Solar Panel Installations

City of Riverside Building & Safety Division Phone: (951)

Extend the Life of Existing Switchgear

Applications. Remote Display Mounting Kits

Harmonics in your electrical system

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

Application of Four-Pole Circuit Breakers within Data Centers

APC 3Phase Power Distribution

Mission Critical Data Center Systems

BRANDON AND CLARK INC. // SCOTT W. CLARK, P.E. ELECTRICAL CONTINUING EDUCATION ARC FLASH - NFPA 70E

IRRIGATION PUMPING Table of Contents - Section 900

Contents. Clean Control Center Harmonic Correction Unit. Selection Dimensions Specifications. Description

Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems

Atlanta Chapter IEEE Industry Applications Society

Evaluating Fire- and Heat-Damaged Electrical Equipment

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

Electrical Distribution Services for Mining and Metals Industries

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

Transcription:

510 N. Crosslane Rd. Monroe, Georgia 30656 (770) 266-6915 fax (678) 643-1758 Engineers Edge, LLC PDH & Professional Training Copyright, All Rights Reserved Engineers Edge, LLC

An Introduction to Interior Electrical Distribution Systems J. Paul Guyer, P.E., R.A. Paul Guyer is a registered civil engineer, mechanical engineer, fire protection engineer, and architect with over 35 years of experience in the design of buildings and related infrastructure. For an additional 9 years he was a senior advisor to the California Legislature on infrastructure and capital outlay issues. He is a graduate of Stanford University and has held numerous national, state and local positions with the American Society of Civil Engineers, Architectural Engineering Institute and National Society of Professional Engineers. J. Paul Guyer 2013 1

CONTENTS 1. INTRODUCTION 2. GENERAL POWER SYSTEM CRITERIA 3. POWER DISTRIBUTION AND UTILIZATION 4. GLOSSARY (This publication is adapted from the Unified Facilities Criteria of the United States government which are in the public domain, are authorized for unlimited distribution, and are not copyrighted.) J. Paul Guyer 2013 2

1. INTRODUCTION 1.1 PURPOSE AND SCOPE. The criteria contained herein are intended to ensure economical, durable, efficient, and reliable systems and installations. Whenever unique conditions and problems are not specifically covered by this publication, use the applicable referenced industry standards and other documents for design guidance. 1.2 APPLICABILITY. This publication typically applies up to 5 foot beyond the facility envelope. It also applies to: Service(s) supplying power from the utility system utilization transformer to the wiring system of the facility. Circuits originating from within the facility that extend beyond the facility envelope. Wiring and connections for supplemental grounding systems. Wiring from and connections to non-utility equipment supplying power to the wiring system of the facility, including engine-generator sets, photovoltaic power systems and fuel cells. In addition to NFPA 70 requirements, facilities located outside of the United States must also comply with the applicable host nation standards. Host nation voltage and frequency shall generally apply. Different wiring and grounding conventions usually apply in other host nations; however, follow the design principles provided in this publication to the extent practical. 1.3 GENERAL BUILDING REQUIREMENTS. Comply with applicable building codes. 1.4 REFERENCES. Applicable references are provided in this publication. 1.5 DESIGN STANDARDS. Comply with the requirements of National Fire Protection Association (NFPA) 70, National Electrical Code, and the requirements herein. (Note: When a project, or portion of a project, has been designated as requiring Critical J. Paul Guyer 2013 3

Operations Power Systems (COPS) treatment as a Designated Critical Operations Area (DCOA) per NFPA 70 Article 708, the requirements that are more stringent than this publication take precedence over this publication.) Codes and standards are referenced throughout this publication. The publication date of the code or standard is not routinely included with the document identification throughout the text of the document. In general, the latest issuance of a code or standard has been assumed for use. J. Paul Guyer 2013 4

2. GENERAL POWER SYSTEM CRITERIA 2.1 VOLTAGE. Unless there are specialty voltage requirements, the facility system voltage shall be based on the interior load requirements as follows: Apply 240/120V for small facilities with only single-phase loads. Apply three-phase, four-wire, 208Y/120V systems for lighting and power demand loads less than 150 kva. Apply three-phase, four-wire, 480Y/277V systems for lighting and power demand loads greater than 150 kva unless 208Y/120V systems are shown to be more costeffective. Use step-down transformers inside the facility as required to obtain lower voltages. 2.2 FREQUENCY. Apply a frequency of 60 Hz for distribution and utilization power. In locations in which the commercially-supplied frequency is other than 60 Hz, such as 50 Hz, use the available supplied frequency to the extent practical. Where frequencies other than that locally available are required for technical purposes, frequency conversion or generation equipment can be installed. J. Paul Guyer 2013 5

3. POWER DISTRIBUTION AND UTILIZATION 3.1 TRANSFORMERS. The transformer design criteria provided herein apply to interior applications. Commonly, facilities will be supplied by an exterior utility system padmounted transformer. 3.1.1 LOW VOLTAGE TRANSFORMERS. Specify dry-type transformers in accordance with NEMA ST 20 and the following: For transformers rated for 15 kva or larger, use transformers with a 220 degree C (428 degrees F) insulation system not to exceed an 115 degree C (239 degrees F) rise capable of carrying continuously 115 percent of nameplate kva without exceeding insulation rating at a maximum ambient temperature of 40 degrees C (104 degrees F). Provide a transformer of 80 degrees C temperature rise capable of carrying continuously 130 percent of nameplate kva without exceeding insulation rating when additional overload capacity is required. Transformers rated less than 15 kva can use a 180 degree C (356 degrees F) insulation system not to exceed an 80 degree C (176 degrees F) rise at a maximum ambient temperature of 40 degrees C (104 degrees F). When the transformer is located in areas where noise is a factor, specify sound levels at least 3 decibels below recommended values established by NEMA ST 20. Derate the transformer in accordance with the manufacturer s guidance for locations with a maximum ambient temperature above 40 degrees C (104 degrees F) and in accordance NEMA ST 20 for altitudes higher than 3,300 feet (1,000 meters). Include the following as part of the installation: Mount the transformer so that vibrations are not transmitted to the surrounding structure. Small transformers can usually be solidly mounted on a reinforced concrete floor or wall. Flexible mounting will be necessary if the transformer is mounted to the structure in a normally low-ambient noise area. J. Paul Guyer 2013 6

Use flexible couplings and conduit to minimize vibration transmission through the connection points. Locate the transformer in spaces where the sound level is not increased by sound reflection. For example, in terms of sound emission, the least desirable transformer location is in a corner near the ceiling because the walls and ceiling function as a megaphone. Transformer spaces shall be adequately ventilated to prevent the temperature rise from exceeding the transformer rating. Refer to TSEWG TP-5, Interior Transformer Ratings and Installation, for additional information regarding transformers and transformer ratings. 3.1.2 OTHER TRANSFORMERS. Do not use unless justified and documented in the design analysis. 3.2 SERVICE ENTRANCE AND DISTRIBUTION EQUIPMENT. Locate service entrance equipment and other major electrical equipment in a dedicated electrical equipment room. Provide a main breaker on each service entrance. Locate other electrical equipment, such as electrical panels, in dedicated spaces. Use 100 percent rated main overcurrent device for sizes 400 ampere and larger. Size circuit breaker interrupting ratings based on the available short circuit current; however, do not select circuit breakers less than 10 ka symmetrical interrupting rating for voltages 240V and below and 14 ka symmetrical interrupting rating for 480V applications. Do not use series-combination rated breakers or fusible overcurrent devices. 3.2.1 SWITCHGEAR AND SWITCHBOARDS GENERAL CRITERIA. Select lowvoltage switchboards versus switchgear as follows: Specify switchboards for service entrance equipment when the service is 1200A or larger, and branch and feeder circuits are combined sizes from 20A up to 800A. J. Paul Guyer 2013 7

Utilize switchboards throughout the distribution system where feeders are 1200A or larger. Devices must be front accessible and must be completely isolated between sections by vertical steel barriers. Switchboards should have hinged fronts to allow safer maintenance access. Specify metal clad switchgear for service entrance equipment only when the service is 1200A or larger, and all branch and feeder circuits are large, such as 600A or 800A each. The circuit breakers must be electrically operated. The switchgear and circuit breakers must be the product of the same manufacturer. Consider remote racking device designs (robots) to rack breakers in and out. Select switchgear and switchboards of the dead-front, floor-mounted, freestanding, metal-enclosed type with copper bus and utilizing circuit breakers as circuit protective devices. Provide a minimum of 20 percent space-only cubicles and appropriate bus provisions for future protective device additions to accommodate planned load growth. Ensure switchboards are designed in accordance with NEMA PB 2 and UL 891 listed. Place a safety sign on any cubicles containing more than one voltage source. Refer to ANSI Z535.4 for safety sign criteria. 3.2.2 PANELBOARDS. Specify panelboards for service entrance equipment when the service is less than 1200A and feeder circuits will fit in one panelboard. Equip panelboards with separate ground bus bars and insulated neutral bus bars to isolate the bus bar, when required by code, from the panelboard. Circuit breakers must be bolt-on type. Do not use dual section panelboards. Provide a minimum of 20% empty space for all panelboards. For flush-mounted panelboards, provide spare conduits extending up above the ceiling and down below raised floors when applicable. Provide one spare conduit, minimum of ¾-inch (18 mm), for every three empty spaces. Use panelboards for service entrance equipment and electrical distribution in residential facilities. Load center style panelboards, /1/ with plug-in breakers, can be used in housing units and residential rooms. Ensure circuit breakers used as switches in 120V and 277V lighting circuits are listed for the purpose and are marked SWD or HID (switching duty or high-intensity discharge lighting). Provide arc-fault circuit interrupter protection for J. Paul Guyer 2013 8