NEOGARD. Preventive Maintenance Manual



Similar documents
Commercial Roof Management

SELF-INSPECTION CHECKLIST Maintain Your Roof and Identify Potential Issues With Bloom s Comprehensive Self-Inspection Guide

RECOATING AND RENEWING SPF ROOFING SYSTEMS

ROOF INSPECTION & MAINTENANCE

CARLISLE OWNER S MANUAL

The Perfect Fit For Metal Retrofit

Maintenance & Inspection Guide

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

Warranty Information TABLE OF CONTENTS PROCEDURES FOR WARRANTY 2

METAL ROOF RESTORATION SAMPLE DESIGN GUIDELINES

FLAT ROOF REPAIR CUT COST WITHOUT CUTTING CORNERS

Colorado State University. Durrell Center Roof Repair

Building Owners Guide to a Duro-Last System!

Commercial Roof Inspection Form

Reroof or Restore? The right decision can save weeks of time and thousands of dollars

THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER

Rooftop Matters Benchmark Report. Executive Summary

WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM

THERMOTEK SELF ADHESIVE MEMBRANE +G2 OVER WOOD SYSTEM DESCRIPTION SELF ADHESIVE OVER WOOD (8YR) BS-SA/CS

How to repair your existing low slope flat roof.

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

HEB 38 BLANCO AND WEST AVENUE FLUID APPLIED EPDM RUBBER ROOF RECOVERY SYSTEM APPLICATION

Minor Cracks in Horizontal Surfaces

TITLE: MASONRY PARAPET WALLS AND FLAT ROOF REQUIREMENTS 11/1/09

!!! !!!! !!! !!! !!! !!! !!!!!!!!! Table of Contents! Section 1: Most Common Types of Flat Roofing! Section 2: Better Understand Your Flat Roof!

Why is my air conditioner dripping on my customers?

MODULAR EPDM ROOFING SYSTEMS

T R A N S F E R A B L E F U L LY

WOOD FLOORING MAINTENANCE MANUAL

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER POLYSOCYANURATE SYSTEM DESCRIPTION TORCH SYSTEM OVER POLYISO (15,17,19 YR) TH/BS-TH/CS

Cleaning guide for senior living facilities

ALPHA 15-Year Permathane II FR w/granules

TERMOSIGN APPLICATION INSTRUCTIONS

REPLACE YOUR ROOF TO VISUALLY INSPECT YOUR ROOF REGULARLY SO YOU CAN DISCOVER PROBLEMS WHILE THEY ARE STILL MINOR AND CAN BE REPAIRED.

Bituminous Sheet Flat Roofs: Their repair and maintenance

BLACK JACK ALL WEATHER ROOF COATING

TARRANT COUNTY DETAIL STANDARDS

Columbia flooring will resist fading from exposure to sunlight or artificial light.

Chapter 9: INSTALLING ROOFING

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

Winterizing Your Building

SWD URETHANE COATED FOAM ROOFING SYSTEM MASTER ROOF SPECIFICATION SECTION

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

CHAPTER 5 ASPHALT-SHINGLE ROOFING

Building Envelope Maintenance Bulletin. Decks and Balconies. What are Decks and Balconies? What is a Deck or Balcony Membrane?

Water Damage & Repair

RACKING AND ATTACHMENT CRITERIA FOR EFFECTIVE MEMBRANE ROOF SYSTEM INTEGRATION Public Version 1: July 9, 2012

Crescent Valley High School Roof Investigation

The Rooflight Company s Operations & Maintenance Guide

How To Insure Against Problems With Your Home Warranty

Water Management & Damage Prevention:

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

Roof Owner s Maintenance Manual

BRIDGE FIELD PAINTING, REPAINTING, 412 AND PAINT RESIDUE CONTAINMENT. A. Field Painting, Bridge Repainting and Residue Containment:

PTAC Preventive Maintenance Guide. Step-by-step instructions and information to keep your units operating in peak condition

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

Walking/Work Surfaces Fall Protection Program

Good Housekeeping BMP

Monthly Inspection Checklists

XONYX Solid Surface Owner's Manual

A. This Section includes rubberized asphalt sheet membrane waterproofing systems.

City of Paso Robles Community Development Department Construction Site Storm Water Quality Requirements

Slips, Trips and Falls

bmc The experience you can

BASEMENT FLOODING. Prevention Guide for. Homeowners

Inspections Standard Operating Procedure 5 Aboveground Storage Tanks

T H A N K Y OU F O R Y OUR P U R C H A S E O F A N E S S E N T I A V A N I T Y, P L E A S E R E A D T H E S E V A N I T Y C A R E A N D I N S T A L L

SAFEGUARDING YOUR EMPLOYEES AND CUSTOMERS: MITIGATING SLIP AND FALL RISKS

Chapter 2 Stormwater Pollution Prevention Plan (SWPPP) for Park Operations

GUTTER HELMET MANUFACTURER'S WARRANTIES: Lifetime Material Warranty

Metal Rescue Rust Remover Technical Data

HOMEOWNER MAINTENANCE MANUAL

Amtico and Spacia Commercial Maintenance Guidelines

Roof Condition Analysis

A. Work on this project shall consist of, but is not limited to, the following:

INSTRUCTION FOR ASSEMBLY. 150x180 v Traditional sauna cabin

FEFPA 2015 SUMMER CONFERENCE. Energy Effectiveness through Roof Coatings and Solar

Shingle Roofing: What s below the surface is important

ULTRA 865HD HIGH PERFORMANCE MULTI PURPOSE GREASE

Roof Maintenance Scope of Work

CHAPTER 6 ASPHALT ROLL ROOFING

White rust on galvanized and galvanized pre-painted steel. Technical Information

Maintenance & repair Solutions

Terms of Reference Air Handling Unit (HVAC System) Cleaning

Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.

PATHWAY Classic Series with Handrails Portable Wheelchair Ramp INSTRUCTIONS FOR USE 6428 REV A

ABSeam Panel Overview and Installation Instructions

How To Replace A Roofing System In Florida

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

The existing roof angle change terminations and flashings when sound and intact can be reused.

Transcription:

NEOGARD Preventive Maintenance Manual Fluid-Applied Roof Coating Systems December 2014

Notes

NEOGARD luid-applied roof coating systems are designed to be long lasting, monolithic membranes which provide years of trouble-free service. Good general maintenance practices along with preventive maintenance will ensure that the coating system will continue to provide service for which it is intended. NEOGARD strongly encourages the original coating system applicator be retained for inspections, repairs and cleaning in order to simplify warranty issues involved in alterations or repairs. Know Your Roof System Be familiar with the type of roof coating system installed on your facility. Silicone, urethane and acrylic coatings meet different demands and require different products for minor repairs. Keep a roof system ile that includes a copy of the signed warranty document, product data, a copy of previous inspection reports and contact information for the roof coating applicator and NEOGARD. Some common causes of damage to roof coating systems are: HVAC repair and maintenance or other roof trafic Tree limbs, leaves, birds, animals and other debris Drainage failures Oil, grease or chemical releases from vents Excessive movement of the building Damage caused by storms, strong winds or hail Damage caused by snow or ice removal Damage caused by vandals, particularly objects thrown on the roof General Maintenance Unprotected areas of the roof coating system are more susceptible to damage from recurring foot trafic. Care must be used to avoid damage to the system. Exercise caution when walking on the roof system during times of freezing temperatures since ice or frost build up may not be easily visible on light colored surfaces. Exercise care with tools and equipment to avoid puncturing the system when it is necessary for workers to be on the roof to service rooftop equipment, (HVAC units, antennas, etc.). When servicing units, take care when placing metal doors, lids, pans, or sharp objects on the system surface. Avoid coating system damage by installing smooth plywood over the system prior to moving rooftop units, or erecting equipment such as ladders or scaffolding. Preventive Maintenance Manual - Fluid-Applied Roof Coating Systems 1

Remove all debris (such as tree limbs, glass, bolts, nails, screws, metal shavings, etc.) and any other material that may promote punctures or cuts to the system. Provide proper drainage. Keep the roof surface clean of leaves, twigs, paper and accumulated dirt at drain areas to avoid clogged drains. Screens and strainers should be in place at gutters, scuppers and drains. Condensate from HVAC units should be piped to drains. Ponding of water on the surface of the system will increase the probability of moisture entering the structure in the event of a puncture or cut in the system. Do not expose the roof coating system to harmful products or chemicals. These may include: Liquids containing petroleum products Solvents Grease used for lubricating roof top units Oils (new or old) used for air conditioning or compressor units Kitchen waste or other animal fats Chemicals Note: Installation of catch pans and proper drainage of these pans may be used for system protection. Prolonged exposure to these materials may cause swelling and possible degradation of the roof coating system. Remove all material spills which may be harmful to the system (solvent based materials, oil based paint, etc.). Avoid damaging the system when snow/ice removal is necessary. Use plastic shovels and pay particular attention when working around curbs or other areas where lashing can be damaged. Snow blowers and shovels with sharp edges must not be used. Preventive Maintenance Preventive maintenance procedures should include physical inspections and periodic cleaning. Physical Inspections The building owner should establish a semi-annual roof inspection program. Inspections should be conducted by qualiied personnel (ideally the original coating applicator), preferably in the spring and fall. 2 Preventive Maintenance Manual - Fluid-Applied Roof Coating Systems

Inspections should include: The coating system for proper adhesion to the substrate, adhesive or cohesive failure and physical damage. Drains or scuppers to ensure they are operational and that screens and strainers are in place. Areas where change of plane occurs to determine if there has been excessive movement causing the roof coating to split, crack or the sheet rubber lashing to lose adhesion. Roof coating surface to determine if there are any holes, cuts or ruptures present. Areas which are subject to increased trafic damage for abrasion and wear or other physical damage. Where applicable, the underside of structure for evidence of leaks. Identiication and removal of all foreign materials such as tree limbs, leaves, abandoned equipment, parts or other debris. Roof is subject to vandalism. In addition to the scheduled semi-annual inspections, roof inspections should also be conducted whenever any of the following conditions occur: Exposure of the roof to severe weather conditions, such as strong winds, hail or continuous heavy rainfall. After repair or replacement of rooftop equipment, and at any other time when the roof may become exposed to activities of other trades where damages may occur. Periodic Cleaning Improper cleaning procedures can damage the roof coating system. If possible, cleaning should be performed by the original roof coating applicator. Cleaning is designed to remove debris and common dirt, fungus, algae and identify roof coating system damage/deiciencies. Recommendations for cleaning are: Remove all large debris, screws, abandoned equipment or parts. Hose down entire deck with water and NEOGARD s 8500 BioDegradable Cleaner (BDC). Dilute the BDC concentrate with 10 parts water to 1 part cleaner. Apply the diluted cleaning solution to the substrate at a rate of 150 to 200 square feet per gallon. Allow the solution to stand for 15 minutes. Do not allow the solution to dry. Areas with heavy dirt build up may require additional solution as well as scrubbing with a softbristled broom to loosen dirt. Before solution dries, rinse the surface with clean water until cleaning solution has been fully removed. Preventive Maintenance Manual - Fluid-Applied Roof Coating Systems 3

Roof Alterations and Roof Coating Repairs Emergency Roof Coating Repairs This section is included for emergency roof coating repairs only. Minor repairs may be made by owner s maintenance personnel; however, it is recommended to contact the original roof coating applicator to make permanent repairs to protect the integrity of the roof coating system. To make an emergency repair, carefully remove loose coating from damaged area back to well adhered material and thoroughly clean the exposed substrate and existing coating surrounding the area with a clean cloth that has been wet with aromatic solvent. Allow solvent to evaporate. Utilize one part polyurethane sealant (for urethane and/or acrylic roof coatings) or silicone sealant (for silicone roof coatings) to ill tears or punctures. DO NOT use aluminized coatings, asphalt or tar modiied products. After emergency repairs are made, report them to the roof coating system applicator and/or NEOGARD Warranty Department immediately. In order for the warranty to be honored, all emergency repairs must be inspected or reworked by the roof coating applicator that is party to the NEOGARD Warranty. In the event the applicator of record is not available, contact NEOGARD for an alternate NEOGARD approved rooing applicator. Roof Alterations To assure the continuation of the Warranty, any modiications or alterations to the rooing system (addition of units, pipes, satellite dishes, etc.) must be communicated to NEOGARD prior to proceeding. The proposed modiication or alteration details will be reviewed by NEOGARD to determine compliance with NEOGARD s Roof Coating System speciications. Coordinate the installation with the original roof coating system applicator so the modiication/alteration is in accordance with NEOGARD s roof coating system speciications and details. 4 Preventive Maintenance Manual - Fluid-Applied Roof Coating Systems

Notes

NEOGARD Div. of JONES-BLAIR 2728 Empire Central - Dallas, Texas 75235 - Phone (214) 353-1600 - Fax (214) 357-7532 - www.neogard.com