HELPY L300 START-UP GUIDE
HELPY L300 ALARM SYSTEM CONFIGURATION: OR - HELPY L300 - Active handsfree terminal to be placed behind COP - Passive handsfree terminal with emergency pushbutton to be placed on the cartop - Active handsfree terminal with emergency pushbutton to be placed on the shaft-pit - Telephone handset to be placed in the machine room / lift controller - GSM200 gateway GSM200 (5IG-004) - UNIVERSAL GSM500 GC GATEWAY OR ANALOG EXTERNAL LINE GSM500 GC (5CT-061) OR 5HV-004 CAR-TOP BEHIND COP 5HV-001 SHAFT-PIT Telephone handset (4TS-101) 5HV-003
CONNECTING A GSM GATEWAY INSERTING THE SIM CARD you insert the SIM card. GSM200 GSM500 Press the plastic case to open by using a screwdriver. Insert / replace the SIM card by acting on the SIM CARD holder. GSM200 GSM500 SUPPLYING THE UNIVERSAL GATEWAY GSM500 GC PLUG RJ11 telephone line Adapter 230 Vac / 12Vdc Telephone line External + 12 Vdc For connection of the external power supply and the telephone line, please use either the dedicated plugs or the built-in screw terminals. TO CONNECT THE BUILT-IN BATTERY PACK, PLEASE INSERT THE CONNECTOR INTO THE DEDICATED SOCKET - ONLY FOR GSM500 GC VERSION-
REMOVING THE COVER L300 REMOVE THE SCREW OPEN THE CASE CONNECTING THE GSM200 (5IG-004) RJ45 RJ45 To connect the GSM200 gateway to the autodialer HELPY L300, please use the cable RJ45. The GSM200 is directly supllied by the autodialer. IMPORTANT: Dial 661 to program GSM200 line AND: SET THE MINIJUMPER AS SHOWN IN THE PICTURE JP 12 CONNECTING THE GSM500 GC (5CT-061) OR ANALOG EXTERNAL LINE The Universal gateway GSM500 or the PSTN line must be connected to the LTI terminal block. IMPORTANT: Dial 660 to program PSTN line or GSM500 line AND: LEAVE THE JUMPERS AS SET BY FACTORY DEFAULT JP 12
CONNECTING POWER SUPPLY 230 Vac FAST-ON PLUG REMOVE THE PROTECTION OF THE 230 Vac TERMINAL BLOCKS TO CONNECT THE POWER SUPPLY. 7BA-10001 CONNECTING ACTIVE HANDSFREE TERMINAL (BEHIND COP) AND PUSHBUTTON CONNECTING ACTIVE HANDSFREE TERMINAL 1. Connect the terminal block vv1 - of the autodialer to the terminal block - of the handsfree terminal 2. Connect the terminal block vv1 + of the autodialer to the terminal block + of the handsfree terminal CONNECTING THE DOUBLE-CONTACT ALARM PUSHBUTTON 1. Connect the terminal block VV1 - to any of the contacts of the alarm pushbutton 2. Connect the terminal block AL1 of the autodialer to the other contact of the alarm pushbutton AL1 - Cabin Pushbutton B A - +
CONNECTING PASSIVE HANDSFREE TERMINAL WITH PUSHBUTTON (CAR-TOP) 1. Connect the terminal block B of the passive handsfree terminal to the terminal block B of the active handsfree terminal 2.Connect the terminal block A of the passive handsfree terminal to the terminal block A of the active handsfree terminal 3. Connect the terminal block - of the passive handsfree terminal to the terminal bloc k - of the active handsfree terminal 4. Connect one of the passive handsfree terminal s pushbutton contact to the terminal block - of the passive handsfree terminal 5. Connect the free pushbutton contact to the terminal block AL1 of the autodialer + - A B To connect the passive handsfree terminal and the active handsfree terminal please use a shielded cable. B A - + 5HV-004 PASSIVE HANDSFREE TERMINAL WITH PUSHBUTTON 5HV-001 ACTIVE HANDSFREE TERMINAL CONNECTING PASSIVE HANDSFREE TERMINAL WITH PUSHBUTTON (SHAFT-PIT) 1. Connect the terminal block + of the active handsfree teminal to the terminal block VV2 + of the autodialer 2. Connect the terminal block - of the active handsfree teminal to the terminal block VV2 - of the autodialer 3. Connect the terminal block - of the active handsfree terminal to one of the handsfree pushbutton contacts 4. Connect the free pushbutton contact to the terminal block AL2 of the autodialer B A - + 5HV-003 ACTIVE HANDSFREE TERMINAL WITH PUSHBUTTON
CONNECTING THE TELEPHONE IN THE MACHINE ROOM AND THE SIGNALLING LEDs 1. Connect the plug RJ11 to the telephone in the machine room 2. Connect the conductors to the terminal block TEL of the autodialer NOTE: To connect the telephone it is possible to use also the RJ11 plug, located above the terminal blocks. 3. Connect the Alarm sent Led to the terminal block AI and to the terminal block - of the autodialer. 470 Ohm 1/2 W 470 Ohm 1/2 W 4. Connect the Alarm recaived Led to the terminal block AR and to the terminal block - of the autodialer. Ar Ai NOTE: Make sure that the existing pushbuttons lights are equipped with internal resistors. RJ11