Zetron Desktop Microphone Manual F

Size: px
Start display at page:

Download "Zetron Desktop Microphone Manual 025-9589F"

Transcription

1 Zetron Desktop Microphone Manual F

2 Software License The Zetron software described in this manual is subject to the terms and conditions of Zetron's Software License Agreement, a copy of which is contained on the product distribution media or otherwise provided or presented to buyer. Installation and/ or use of the Zetron software constitutes acceptance of Zetron's Software License Agreement. Limited Warranty Buyer assumes responsibility for the selection of the Products to achieve buyer's or its customer's intended results obtained from the Products. If buyer has provided Zetron with any requirements, specifications or drawings, or if Zetron provides buyer with such materials, such materials are provided solely for buyer's convenience and shall not be binding on Zetron unless agreed in writing by the President of Zetron. ZETRON DOES NOT WARRANT THAT THE PRODUCTS OR ITS CUSTOMER'S REQUIREMENTS OR SPECIFICATIONS OR THAT OPERATION OF THE PRODUCTS WILL BE UNINTERRUPTED OR ERROR FREE. SUBJECT TO THE LIMITATIONS SET FORTH BELOW, Zetron warrants that all Zetron Products and Zetron Accessories will be free from material defects in material and workmanship for one year from date of shipment (except where indicated otherwise in the Zetron Price Book). For buyer's convenience, Zetron may purchase and supply additional items manufactured by others. In these cases, although Zetron's warranty does not apply, buyer shall be the beneficiary of any applicable third party manufacturer's warranties, subject to the limitations therein. Zetron's warranty covers parts and Zetron factory labor. Buyer must provide written notice to Zetron within the warranty period of any defect. If the defect is not the result of improper or excessive use, or improper service, maintenance or installation, and if the Zetron Products or Zetron Accessories have not been otherwise damaged or modified after shipment, AS ZETRON'S SOLE AND EXCLUSIVE LIABILITY AND BUYER'S SOLE AND EXCLUSIVE REMEDY, Zetron shall either replace or repair the defective parts, replace the Zetron Products or Zetron Accessories or refund the purchase price, at Zetron's option, after return of such items by buyer to Zetron. Shipment shall be paid for by the buyer. No credit shall be allowed for work performed by the buyer. Zetron Products or Zetron Accessories which are not defective shall be returned at buyer's expense, and testing and handling expense shall be borne by buyer. Out-of-warranty repairs will be invoiced at the then - current Zetron hourly rate plus the cost of needed components. THE FOREGOING WARRANTY AND THE THIRD PARTY MANUFACTURER'S WARRANTIES, IF ANY, ARE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESSED, IMPLIED OR ARISING UNDER LAW, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY, NON-INFRINGEMENT AND FITNESS FOR A PARTICULAR PURPOSE. Limitation of Liability Zetron makes no representation with respect to the contents of this document and/or the contents, performance, and function of any accompanying software. ZETRON SHALL NOT UNDER ANY CIRCUMSTANCES BE LIABLE TO BUYER OR ANY THIRD PARTY FOR ANY INCIDENTAL, SPECIAL, CONSEQUENTIAL OR INDIRECT LOSS OR DAMAGE ARISING OUT OF OR CONNECTED WITH BUYER'S PURCHASE OR USE OF PRODUCTS OR SERVICES, INCLUDING WITHOUT LIMITATION, LOSS OF USE, LOSS OR ALTERATION OF DATA, DELAYS, LOST PROFITS OR SAVINGS, EVEN IF ZETRON HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES AND EVEN IF THE LIMITED REMEDY ABOVE IS FOUND TO FAIL OF ITS ESSENTIAL PURPOSE. IN NO EVENT SHALL ZETRON'S LIABILITY (WHETHER FOR NEGLIGENCE OR OTHER TORT, IN CONTRACT OR OTHERWISE) EXCEED THE PRICE PAID TO ZETRON FOR THE PRODUCTS. IP networks by their nature are subject to a number of limitations, such as security, reliability, and performance. Anyone using non-dedicated IP networks, such as shared WANs or the Internet, to connect to any Zetron Products or systems should consider and is responsible for these limitations. Zetron, Inc. All rights reserved. This publication is protected by copyright; information in this document is subject to change without notice. Zetron and the Zetron logo are registered trademarks of Zetron, Inc. Other company names and product names may be the trademarks or registered trademarks of their respective owners. This publication may not be reproduced, translated, or altered, in whole or in part, without prior written consent from Zetron, Inc.

3 Compliance Statements Information on Disposal of Old Electrical and Electronic Equipment and Batteries (applicable for EU countries that have adopted separate waste collection systems) Products and batteries with the symbol (crossed-out wheeled bin) cannot be disposed as household waste. Old electrical and electronic equipment and batteries should be recycled at a facility capable of handling these items and their waste byproducts. Contact your local authority for details in locating a recycle facility nearest to you. Proper recycling and waste disposal will help conserve resources whilst preventing detrimental effects on our health and the environment. Notice: The sign Pb below the symbol for batteries indicates that this battery contains lead. Safety Summary STOP Warning! For your safety and the protection of the equipment, observe these precautions when installing or servicing Zetron equipment: Follow all warnings and instructions marked on the equipment or included in documentation. Only technically qualified service personnel are permitted to install or service the equipment. Be aware of and avoid contact with areas subject to high voltage or amperage. Because some components can store dangerous charges even after power is disconnected, always discharge components before touching. Never insert objects of any kind through openings in the equipment. Conductive foreign objects could produce a short circuit that could cause fire, electrical shock, or equipment damage. Remove rings, watches, and other metallic objects from your body before opening equipment. These could be electrical shock or burn hazards. Ensure that a proper electrostatic discharge device is used, to prevent damage to electronic components. Do not attempt internal service of equipment unless another person, capable of rendering aid and resuscitation, is present. Do not work near rotating fans unless absolutely necessary. Exercise caution to prevent fans from taking in foreign objects, including hair, clothing, and loose objects. Use care when moving equipment, especially rack-mounted modules, which could become unstable. Certain items may be heavy. Use proper care when lifting. 3

4 Change List for Rev F, 11 May 2012 Added conditional text and graphics, as necessary, to support printing manual under two brands F

5 Contents Contents Overview Specifications Installation Attaching a Cable Connecting to Consoles Acom, MAX Dispatch, and VoIP RDS Consoles with Wire Connections Desktop Microphone Amplifier (Optional) Specifications Configuration Connection

6 Contents F

7 Overview The Zetron Desktop Microphone is a robust gooseneck-style microphone designed for high audio quality, ruggedness, and the ability to connect directly to Zetron equipment. Standard Shure There are two variants of the Zetron Desktop Microphone. Each variant has a different microphone element. Variant Part Number Zetron Desktop Microphone, standard Zetron Desktop Microphone, Shure Optional and Replacement Parts Option Part Number Desktop Microphone Amplifier, Enhanced foot shielded cable RJ45 to RJ foot shielded cable RJ45 to tails

8 Overview Specifications Microphone base Isolated double wide primary pushbutton, red (usually assigned Transmit function) Isolated secondary pushbutton, white (usually assigned Monitor function) Switch life rating: 50 million cycles at 5V Switch voltage rating: 2 to 12 V DC Switch current rating: 10 ua to 10 ma Standard microphone Cardioid pickup pattern (noise canceling) Dynamic microphone cartridge Isolated balanced output (Mic+ and Mic-) Always live microphone output Frequency response: 100 to 12 khz Impedance: 600 ohm Sensitivity: -52 dbv / Pa (-72 dbv / ubar) 8.5 inch (21.6 cm) gooseneck SHURE microphone Cardioid pickup pattern (noise canceling) Dynamic microphone cartridge Isolated balanced output (Mic+ and Mic-) Always live microphone output Frequency response: 100 to 7 khz Impedance: 170 ohm Sensitivity: dbv / Pa Hum pickup: Max 15 db equivalent in m0e field 12.5 inch (31.7 cm) gooseneck Environmental Operating temperature 0 to 60 degrees C Storage temperature -10 to 70 degrees C Humidity 95% RH at 40 degrees C F

9 Attaching a Cable Installation Attaching a Cable The Zetron Desktop Mic connects internally to a shielded Ethernet patch cable (RJ45). Depending on the model you purchased, this cable may terminate at the other end of the cable with flying leads or another RJ45 connecter, or there may be no cable connected at all. If the cable needs to be replaced, or there is no cable attached, you must first determine if your console equipment requires flying leads or an RJ45 connector. Use Zetron cable (RJ45 to tails) for the following Zetron consoles: Tip Alternatively you can use Zetron cable (RJ45 to RJ45) or a Shielded Ethernet Patch cable and remove the connector from one end. DCS-5020 M7D+ Model 280/284/370/380/390 Model 4010 Series 4000 VoIP RDS (ver 1.7 or older with Audio Control Interface) Use Zetron cable (RJ45 to RJ45) or a shielded Ethernet patch cable for the following Zetron consoles: Acom and Acom EVO MAX Dispatch VoIP RDS (ver 1.8 or newer with VoIP Audio Interface) 9

10 Installation Attaching or replacing a cable to the Zetron Desktop Microphone 1. Remove the three screws as shown in the following figure. Remove Remove Note Do not remove the other two screws. If they are present, they are holding a counterweight to the base. 2. Remove the cover. 3. Connect the cable to the RJ45 jack. 4. Secure the cable with the strain relief mechanism, ensuring there is slack between the connector and the strain relief. Cable should have slack after tightening strain relief 5. Replace the cover and the three screws F

11 Connecting to Consoles Connecting to Consoles Acom, MAX Dispatch, and VoIP RDS Use Zetron Cable (RJ45 to RJ45) or a shielded Ethernet patch cable. The Zetron cable is built to TIA/EIA 568B standards. Console Acom Acom EVO MAX Dispatch VoIP RDS 1.8 or newer Connect To Acom Console Unit (Dual 4W E&M module) or optional Desktop Microphone Amplifier Media Dock (Desk Mic port) Media Dock (Desk Mic port) VoIP Audio Interface (Desk Mic port) Consoles with Wire Connections Use Zetron Cable (RJ45 to tails) or a shielded Ethernet patch cable with one connector removed. The Zetron cable is built to TIA/EIA 568B standards. STOP Warning! The Zetron Desktop Microphone should not be hooked directly to loads that demand a true contact closure. For more detail, refer to the switch ratings in Specifications on page 8. Table 1: Zetron Desktop Microphone wiring connections Mic Cable ( ) Zetron Radio Equipment Pin Wire Color Signal M4010 S4000 (Aux Audio) VoIP RDS Up to 1.7 (ACI) DCS-5020 (DCOAM) Model 280/284 (TB3) Model 360/ 370/380/ 390 (TB3) M7D+ (JP4) 1 White/Orange Mon MON 1 MON 2 Orange Mon 12 3 GND 3 GND 3 White/Green Reserved 4 Blue Mic Audio MIC+ 5 MIC White/Blue Mic Audio 8 4 MIC 4 MIC Green Ground 6 3 GND 3 GND White/Brown PTT PTT 2 PTT Brown PTT 10 3 GND 3 GND

12 Installation Desk Mic Port Mic Cable Pin 1 1 VoIP RDS ACI 1 Note For connecting to Acom consoles, see Desktop Microphone Amplifier (Optional) on page F

13 Desktop Microphone Amplifier (Optional) Desktop Microphone Amplifier (Optional) For Acom consoles, the Zetron Desktop Microphone requires the use of the Zetron Desktop Microphone Amplifier ( ). Specifications Input power voltage: 10.6 to 16 Vdc Input current: under 15 ma Frequency response: 190 to 12.5 khz Amplifier gain: adjustable 39 db to 69 db (in 16 discrete steps) Output noise at 69 db gain: -57 dbm * (EIN = -126 dbm) Output noise at 39 db gain: -82 dbm * (EIN = -121 dbm) * With a 200 ohm input termination With a 600 ohm output termination 0 dbm reference = V rms Configuration Adjusting the gain 1. To open the cover, remove the four screws at the bottom. Desktop Microphone Amplifier JP1 JP2 Input from Mic J1 F ABCDE Gain Adjustment A B A B J2 Output to ACU 2. Use a small screwdriver to turn the gain adjustment pot to the desired gain. For the standard mic ( ), use position 4 (59.2 db gain). For the Shure mic ( ), use position 8 (64.8 db gain). For the AKG GN15 12v phantom powered or Electret 8 Vdc gooseneck microphones, use position 0 (39.1 db gain). The following table shows the db gain provided at each setting. Position A B C D E F Gain (db)

14 Installation 3. If you are using either of the Zetron microphones described in this manual, leave the jumpers at their default setting (open). Otherwise, set the jumpers as needed. Both jumpers must be set to the same position (open, A, or B). Jumper Position Open (default) A B Amplification Setting Zetron Desktop Microphones and dynamic microphones Electret 8Vdc gooseneck mic AKG GN15 12v phantom power 4. Replace the cover and secure it with the four screws. Connection Connecting a Zetron Desktop Microphone to an Acom console 1. Connect the microphone s cable to the RJ45 jack to the Desktop Microphone Amplifier on the side opposite of the red and black wires. If there is no cable attached to the microphone, follow the instructions in Attaching a Cable on page Set the jumpers on the Dual 4-Wire E&M Option as follows: a. Jumpers X9 and X10 must both be set to the 2-3 position (toward the rear panel of the ACU). This selects the internal +12V and GND power supply as the source for +VREF and VREF (respectively), and brings these power supply connections out to the VREF connector on the back panel. b. If the Amplifier will be plugged into Port 1, install jumper X5 and X6 to enable the microphone s PTT and Monitor features. c. If the Amplifier will be plugged into Port 2, install jumper X7 and X8 to enable the microphone s PTT and Monitor features. 3. Configure the 4W E&M card using IMS ACU: a. Right click on 4W E&M card module and select Acom Definitions. b. Select the port connected to the Desktop Microphone. c. For the Connection Type, select Console Interface. d. For the Primary Interface, select Desktop Mic. e. For the Console Number, type the console number assigned to this position. f. Click Save, Exit, then Exit. 4. IMS ACU configuration of 4W E&M card gain settings a. Right click on 4W E&M card module and select Gain settings. b. Set Gain RX to 0 db for the channel (port) connected to the microphone. (For the electret microphone, set to +5 db). c. Click Save, then Close F

15 Desktop Microphone Amplifier (Optional) 5. IMS ACU configuration of 4-wire E&M card AGC settings a. Right click on 4W E&M card module and select AGC Setting. b. Disable Rx AGC for the channel (port) connected to the microphone. c. Click Save, then Close. 6. IMS ACU configuration of 4-wire E&M card inversions a. Right click on 4-wire E&M card and card and select Signalling Inversions. b. Disable any inversions for the channel (port) connected to the microphone. c. Click Save, then Close. 7. Use cable (included with the amplifier) to connect the the ACU Dual E&M Module to the remaining RJ45 jack on the Desktop Microphone Amplifier (the jack adjacent to the red and black wires). See Figure Wire the red and black wires from the Desktop Microphone Amplifier to the screw terminal plug provided with the Dual 4W E&M Module as shown in Figure 1 (red to pin 1 and black to pin 2). The amplifier is polarity-protected. Figure 1: Connecting the Zetron Desktop Microphone to Acom Shielded Ethernet patch cable DUAL 4W E&M Module in ACU DUAL 4W E&M Desktop Microphone Microphone Amplifier to Port 1 or Port 2 PORT 1 VREF PORT 2 Red Black Table 2: Desktop Microphone Amplifier input jack Input (opposite from power wires) Pin Signal Pin 1 1 Mon + 2 Mon 3 Reserved 4 Mic Audio + 5 Mic Audio 6 Ground 7 PTT + 8 PTT Pin 1 15

16 Installation Table 3: Desktop Microphone Amplifier output jack Output (adjacent to power wires) Desktop Mic Amplifier Signal Pin 4W E&M Module Signal PTT 1 E1 Monitor 2 E2 3 Tx A 4 Tx B Audio out 5 Rx A Ground 6 Rx B 7 M1 8 M2 * Active high signals relative Pin 1 Pin F

PagePac PAGEPAL V-5335700

PagePac PAGEPAL V-5335700 PagePac Issue 3 by PAGEPAL V-5335700 INTRODUCTION The PagePal unit interfaces most telephone systems (PBX, KTS, Centrex) to virtually any public address audio system. In addition, PagePal furnishes inputs

More information

Advantium 2 Plus Alarm

Advantium 2 Plus Alarm ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia

More information

Powerware Relay-Serial Card User s Guide

Powerware Relay-Serial Card User s Guide Powerware Relay-Serial Card User s Guide Special Symbols The following are examples of symbols used on the UPS and accessories to alert you to important information: This symbol indicates that you should

More information

QUICK INSTALLATION. 8-Port Telephony Gateway. Model: SPA8000

QUICK INSTALLATION. 8-Port Telephony Gateway. Model: SPA8000 QUICK INSTALLATION 8-Port Telephony Gateway Model: SPA8000 Table of Contents Connect................................................. 4 Regulatory Information....................................12 WEEE

More information

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual. i800 AC Current Clamp Instruction Sheet Introduction The i800 AC Current Clamp, the Clamp, has been designed for use with multimeters, recorders, power analyzers, safety testers, etc., for accurate non-intrusive

More information

How To Install A Power Supply (Uplast) With A Battery Pack

How To Install A Power Supply (Uplast) With A Battery Pack APC Smart-UPS RT SURTA48XLBP/SURTA48XLBPJ External Battery Pack User Manual Introduction/Before Installation About this Manual The APC Smart-UPS RT external battery pack (SURTA48XLBP or SURTA48XLBPJ) connects

More information

BroadBand PowerShield. User Manual

BroadBand PowerShield. User Manual BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains

More information

Model SRMD Setra Remote Monitoring Display

Model SRMD Setra Remote Monitoring Display Model SRMD Setra Remote Monitoring Display 1.0 GENERAL INFORMATION Thank you for purchasing the Setra Remote Monitoring Display (SRMD). The SRMD is a digital panel meter with a bright 1 LED display for

More information

TTL to RS232 Adapter User Guide

TTL to RS232 Adapter User Guide TTL to RS232 Adapter User Guide Revision D March 28, 2011 Document Part Number GC-800-313d Copyright and Trademark Copyright 2006-2011, Grid Connect, Inc. All rights reserved. No part of this manual may

More information

Sunny Boy Accessories SMA POWER BALANCER

Sunny Boy Accessories SMA POWER BALANCER Sunny Boy Accessories SMA POWER BALANCER Installation Guide SBUS-PowBal-IUS102810 IMUS-SBUS-PBL Version 1.0 US SMA America, LLC Legal Restrictions Copyright 2010 SMA America, LLC. All rights reserved.

More information

USER MANUAL DUET EXECUTIVE USB DESKTOP SPEAKERPHONE

USER MANUAL DUET EXECUTIVE USB DESKTOP SPEAKERPHONE USER MANUAL DUET EXECUTIVE USB DESKTOP SPEAKERPHONE DUET EXE OVERVIEW Control Button Panel Connector Panel Loudspeaker Microphone The Duet is a high performance speakerphone for desktop use that can cover

More information

HP UPS R1500 Generation 3

HP UPS R1500 Generation 3 HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications

More information

About this Manual. Support for Your Product

About this Manual. Support for Your Product About this Manual We ve added this manual to the Agilent website in an effort to help you support your product. This manual is the best copy we could find; it may be incomplete or contain dated information.

More information

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. Power Max Level 2 Charging Station en Installation and Operating Instructions This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the

More information

Dolphin 9900 Mobile Computers

Dolphin 9900 Mobile Computers Dolphin 9900 Mobile Computers Dolphin 9900 Dolphin 9950 Dolphin 9951 with Windows Mobile 6.1 Quick Start Guide Dolphin 9900 Series Quick Start Guide Out of the Box Verify that the box contains the following

More information

INSTRUCTION MANUAL MODEL PCD-88

INSTRUCTION MANUAL MODEL PCD-88 INSTRUCTION MANUAL MODEL PCD-88 CLOSED CAPTION DECODER LINK ELECTRONICS, INC. 2137 Rust Avenue Cape Girardeau, Missouri 63703 Phone: 573-334-4433 Fax: 573-334-9255 e-mail: sales @ linkelectronics.com website:

More information

Innkeeper PBX. Desktop Digital Hybrid. User Guide. JK Audio

Innkeeper PBX. Desktop Digital Hybrid. User Guide. JK Audio Innkeeper PBX Desktop Digital Hybrid User Guide JK Audio Introduction Innkeeper PBX will allow you to send and receive audio through your multi-line PBX, ISDN or analog telephone. While this may seem like

More information

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN-00076-A

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN-00076-A 2-3 SAS/SATA II HDD Canister XC-23D1-SA10-0-R USER S MANUAL Document number: MAN-00076-A ii Preface Important Information Warranty Our product is warranted against defects in materials and workmanship

More information

LIM300-EU. Local Input Module Installation Guide

LIM300-EU. Local Input Module Installation Guide LIM300-EU Local Input Module Installation Guide Contents Introduction...3 System setup...4 Mounting...5 Fitting the LIM300...5 Faceplates...7 Wiring guide: EIA/TIA 568A wiring standard...8 connections...8

More information

PBXport. Rackmount PBX Digital Hybrid. User Guide. JK Audio

PBXport. Rackmount PBX Digital Hybrid. User Guide. JK Audio PBXport Rackmount PBX Digital Hybrid User Guide JK Audio Introduction PBXport will allow you to send and receive audio through your multiline PBX, ISDN or analog telephone. While this may seem like a simple

More information

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011 Instruction Manual 2in1 LAN Tester & Multimeter Model: LA-1011 1 Contents Introduction... Features... Safety Precautions.. Meter Description... Electrical Specification... Operation.. AutoRanging Multimeter.

More information

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL 854060

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL 854060 DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL 854060 (FOR DUSTTRAK II AND DRX AEROSOL MONITOR MODELS 8540 AND 8543) OPERATION AND MAINTENANCE MANUAL P/N 6008416, REVISION A MAY 2015 Copyright TSI Incorporated

More information

UniStream CPU-for-Panel

UniStream CPU-for-Panel UniStream CPU-for-Panel Installation Guide USC-P-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for industrial automation. This guide provides basic

More information

TELIKOU Intercom System. MS-500(4+1 channel) Main Station Instruction Manual

TELIKOU Intercom System. MS-500(4+1 channel) Main Station Instruction Manual TELIKOU Intercom System MS-500(4+1 channel) Main Station Instruction Manual TELIKOU Systems All Rights Reserved While TELIKOU makes every attempt to maintain the accuracy of the information contained in

More information

Take-2 by Nel-Tech Labs, Inc. Installation & User Manual

Take-2 by Nel-Tech Labs, Inc. Installation & User Manual Take-2 by Nel-Tech Labs, Inc. Installation & User Manual Index: Introduction... 3 Take-2 Layout Summary... Installation... 4 5-6 Warranty & FCC... 7 Introduction: The Take-2 is a state-of-the-art message-on-hold

More information

USER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun)

USER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun) USER MANUAL MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun) An ISO-9001 Certified Company Part #07M460-E Doc. #019021UE Revised 02/23/00 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301)

More information

Universal Wireless Effects Controller USER S GUIDE SA115

Universal Wireless Effects Controller USER S GUIDE SA115 Universal Wireless Effects Controller USER S GUIDE SA115 Welcome Thank you for purchasing this Hot Hand 3 Universal Wireless Effects Controller. We hope that the new functionality of the Hot Hand 3 unit

More information

LDG SLS-2 Two-Port RJ45 Switch

LDG SLS-2 Two-Port RJ45 Switch SLS-2 OPERATIONS MANUAL MANUAL REV. A LDG SLS-2 Two-Port RJ45 Switch LDG Electronics 1445 Parran Road St. Leonard MD 20685-2903 USA Phone: 410-586-2177 Fax: 410-586-8475 ldg@ldgelectronics.com www.ldgelectronics.com

More information

IEEE 802.3af 4-Port Power over Ethernet Injector Hub POE-400. User s Manual

IEEE 802.3af 4-Port Power over Ethernet Injector Hub POE-400. User s Manual IEEE 802.3af 4-Port Power over Ethernet Injector Hub POE-400 User s Manual - 1 - Trademarks Disclaimer Copyright PLANET Technology Corp. 2006. Contents subject to revision without prior notice. PLANET

More information

=============================== WARNING

=============================== WARNING =============================== WARNING EXPLANATION OF GRAPHICAL SYMBOLS This symbol is intended to alert the user to the presence of unprotected dangerous voltage" within the product's enclosure that

More information

MultiVOIP FX SIP Gateways

MultiVOIP FX SIP Gateways MultiVOIP FX SIP Gateways MVPFX2-2 MVPFX2-4 MVPFX2-8 Cabling Guide Cabling Guide MultiVOIP FX SIP Gateways, Models MVPFX2-2, MVPFX2-4, MVPFX2-8 82100090L Rev. A Copyright This publication may not be reproduced,

More information

Nest Learning Thermostat Installation Guide. Installation step-by-step

Nest Learning Thermostat Installation Guide. Installation step-by-step Nest Learning Thermostat Installation Guide Installation step-by-step Contents Compatibility. 3 In the box. 4 Before you start. 5 Choose an installation method. 6 Replacing an existing wired thermostat.

More information

VM-4 USB Desktop Audio Device Installation Guide

VM-4 USB Desktop Audio Device Installation Guide VM-4 USB Desktop Audio Device Installation Guide THE POSSIBILITIES ARE ENDLESS. 9 Austin Drive, Marlborough, CT 06447 (860) 295-8100 www.essentialtel.com sales@essentialtel.com Table of Contents Introduction...3

More information

User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction

User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger

More information

VM-8 USB Desktop Audio Device Installation Guide

VM-8 USB Desktop Audio Device Installation Guide VM-8 USB Desktop Audio Device Installation Guide THE POSSIBILITIES ARE ENDLESS. 9 Austin Drive, Marlborough, CT 06447 (860) 295-8100 www.essentialtel.com sales@essentialtel.com Table of Contents Introduction...3

More information

Telex Operating Instructions

Telex Operating Instructions Telex Operating Instructions Airman 850 General Description The Telex Airman 850 is designed for use in aircraft with low noise levels. Ambient noise levels in such aircraft cockpits may be considered

More information

Crow Limited Warranty. Print Version 017

Crow Limited Warranty. Print Version 017 Crow Limited Warranty (Crow) warrants this product to be free from defects in materials and workmanship under normal use and service for a period of one year from the last day of the week and year whose

More information

i410/i1010 AC/DC Current Clamp

i410/i1010 AC/DC Current Clamp /i1010 AC/DC Current Clamp Instruction Sheet Safety Information XW Read First: Safety Information To ensure safe operation and service of the current clamp, follow these instructions: Read all operating

More information

SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE

SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE SP4LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE INSTALLATION AND OPERATION MANUAL MASS NOTIFICATION SYSTEM Part Number: P84767 Rev. A Copyright 2006 Cooper Wheelock, Inc. All rights reserved.

More information

Sip/Puff Switch User Guide

Sip/Puff Switch User Guide Sip/Puff Switch User Guide www.orin.com Table of Contents Table of Contents... 2 Legal Notices... 3 Declaration of Conformity with European Directives... 3 Application Disclaimer... 4 Introduction... 5

More information

±15 V Current-Limited Power Supply

±15 V Current-Limited Power Supply USER S GUIDE ±15 V Current-Limited Power Supply Model 0901 Newport Corporation 3635 Peterson Way Santa Clara, CA 95054 www.newport.com/newfocus Warranty Newport Corporation guarantees its products to be

More information

LDG DTS-4/4R Desktop Coaxial Switch / Remote

LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG Electronics 1445 Parran Road, PO Box 48 St. Leonard MD 20685-2903 USA Phone: 410-586-2177 Fax: 410-586-8475 ldg@ldgelectronics.com www.ldgelectronics.com

More information

Liquid Carbon Balanced Transportable Headphone Amplifier. Cavalli audio. Copyright 2015-2016 Cavalli Audio, LLC All Rights Reserved

Liquid Carbon Balanced Transportable Headphone Amplifier. Cavalli audio. Copyright 2015-2016 Cavalli Audio, LLC All Rights Reserved Liquid Carbon Balanced Transportable Headphone Amplifier Cavalli audio All Rights Reserved Page 2 of 15 Congratulations! You re now the proud owner of the Cavalli Audio Liquid Carbon Balanced Transportable

More information

16/32 Channel 1U Rack Mount CCTV Power Supply

16/32 Channel 1U Rack Mount CCTV Power Supply 16/32 Channel 1U Rack Mount CCTV Power Supply Manual PH-A3224-GUQ Shown 16-Channel 32-Channel PTC PH-A1612-PUQ PH-A3224-PUQ Glass Fuse PH-A1612-GUQ PH-A3224-GUQ Industrial design 12 Amp 3 Amps per channel

More information

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual CelluLine CGW-TS GSM Cellular Gateway Installation and Programming Manual CelluLine CGW-TS GSM Cellular Gateway Installation and Programming Manual CGWTS-M001A Version 1, Release 1, December 2004 NOTICE

More information

CABLE MODEM QUICK START

CABLE MODEM QUICK START CABLE MODEM QUICK START This Quick Start describes how to connect your Zoom cable modem to a cable modem service. This lets your cable modem provide Internet access to a computer or other device connected

More information

Universal Vehicle Power Supply 9007AX01. Installation Instructions

Universal Vehicle Power Supply 9007AX01. Installation Instructions Universal Vehicle Power Supply 9007AX01 Installation Instructions Disclaimer Honeywell International Inc. ( HII ) reserves the right to make changes in specifications and other information contained in

More information

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134 AC 800M EtherNet/IP DeviceNet Linking Device LD 800DN SP1134 Power and productivity for a better world TM AC 800M EtherNet/IP DeviceNet Linking Device LD 800DN NOTICE This document contains information

More information

Installation and Operation Manual. for the. IPC-1, Bi-Directional stereo level matching interface

Installation and Operation Manual. for the. IPC-1, Bi-Directional stereo level matching interface for the Copyright 1996 2004 by All rights reserved. Except as permitted under the United States Copyright Act of 1976, no part of this document may be reproduced or distributed without permission All specifications

More information

LOSB9595 1/36 th Brushless ESC and 10250Kv Motor Combination

LOSB9595 1/36 th Brushless ESC and 10250Kv Motor Combination LOSB9595 1/36 th Brushless ESC and 10250Kv Motor Combination Thank you for purchasing this Losi High Performance Brushless System! This technically advanced system will offer maintenance free operation,

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Samba OPLC SM35-J-R20 Installation Guide The Unitronics SM35-J-R20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include: 1 HSC/Shaft-encoder Input, 2 Analog inputs (only

More information

USER MANUAL. Model 6103 3U ForeFront Alarm Card SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007. An ISO-9001 Certified Company

USER MANUAL. Model 6103 3U ForeFront Alarm Card SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007. An ISO-9001 Certified Company USER MANUAL Model 6103 3U ForeFront Alarm Card An ISO-9001 Certified Company Part# 07M6103 Doc# 123011U Rev. A Revised 7/15/03 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 CONTENTS 1.0

More information

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual Asanté Technologies, Inc. 821 Fox Lane San Jose, CA 95131 Copyright Notice Copyright 1997 by Asanté Technologies, Inc. All rights reserved. No

More information

Installation Guide Smart-UPS X External Battery Pack SMX120BP

Installation Guide Smart-UPS X External Battery Pack SMX120BP Installation Guide Smart-UPS X External Battery Pack SMX120BP Inventory Inspect the contents upon receipt. Notify the carrier and dealer if there is damage. Two bezels Tie brackets used to secure multiple

More information

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U SURT192RMXLBP2 SURT192RMXLBP2J English 990-2485B 02/2009 Introduction About this UPS The American Power Conversion (APC ) SURT192RMXLBP2 external

More information

T7560A,B,C Digital Wall Module

T7560A,B,C Digital Wall Module T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital

More information

SMART Board 8055i and 8055i-SMP

SMART Board 8055i and 8055i-SMP SMART Board 8055i and 8055i-SMP Interactive flat panel Installation guide Product registration If you register your SMART product, we ll notify you of new features and software upgrades. Register online

More information

INSTALLATION. Omega 8000 Series Controller For Use With Omega 90 Siren/P.A. Amplifier

INSTALLATION. Omega 8000 Series Controller For Use With Omega 90 Siren/P.A. Amplifier 22-UM8000-00 ECO# 104-06-MAN INSTALLATION Omega 8000 Series Controller For Use With Omega 90 Siren/P.A. Amplifier FS Unitrol 1108 Raymond Way Anaheim CA 92801 (714)871-3336 (800)854-3375 FAX(714)871- BASIC

More information

StorTrends 3400 Hardware Guide for Onsite Support

StorTrends 3400 Hardware Guide for Onsite Support StorTrends 3400 Hardware Guide for Onsite Support MAN-3400-SS 11/21/2012 Copyright 1985-2012 American Megatrends, Inc. All rights reserved. American Megatrends, Inc. 5555 Oakbrook Parkway, Building 200

More information

MultiVOIP FX FXS-Only SIP Gateways

MultiVOIP FX FXS-Only SIP Gateways MultiVOIP FX FXS-Only SIP Gateways MVPFXS-8 MVPFXS-16 MVPFXS-24 Cabling Guide MultiVOIP MVPFXS-8/16/24 Cabling Guide Cabling Guide MultiVOIP FX SIP FXS-Only Gateways Models MVPFXS-8, MVPFXS-16, MVPFXS-24

More information

Unattended Answering Device Instruction Manual

Unattended Answering Device Instruction Manual Model 3137B Unattended Answering Device Instruction Manual Monroe Electronics 100 Housel Ave Lyndonville NY 14098 800-821-6001 585-765-2254 fax: 585-765-9330 monroe-electronics.com Printed in USA Copyright

More information

TELIKOU Intercom System. TM-200 Main Station. Instruction Manual

TELIKOU Intercom System. TM-200 Main Station. Instruction Manual Intercom System TM-200 Main Station Instruction Manual TELIKOU Systems All Rights Reserved I. Introduction Thank you for choosing TELIKOU intercom product. TM-200 main station is suitable for television

More information

innkeeper PBX Desktop Digital Hybrid User Guide JK Audio

innkeeper PBX Desktop Digital Hybrid User Guide JK Audio innkeeper PBX Desktop Digital Hybrid User Guide JK Audio Introduction Innkeeper PBX will allow you to send and receive audio through your multi-line PBX, ISDN or analog telephone. While this may seem like

More information

innkeeper PBX Desktop Digital Hybrid User Guide JK Audio Warranty

innkeeper PBX Desktop Digital Hybrid User Guide JK Audio Warranty Warranty Innkeeper PBX is covered by a 2-year warranty to be free from defective workmanship and materials. In the event that the innkeeper PBX needs repair, you must call us to get an authorization, and

More information

Universal Host. Desktop Digital Hybrid. User Guide. JK Audio

Universal Host. Desktop Digital Hybrid. User Guide. JK Audio Universal Host Desktop Digital Hybrid User Guide JK Audio Introduction Universal Host will allow you to send and receive audio through your multi-line PBX, ISDN, VoIP or analog telephone. While this may

More information

Owner s Manual & Safety Instructions

Owner s Manual & Safety Instructions Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s

More information

User Manual PT-E-HIP

User Manual PT-E-HIP User Manual PT-E-HIP PT-E-HIP User Manual Contents PT-E-HIP-TX Transmitter 1. Introduction 2. How It Connects 3. Features 4. Transmitter Unit Panel Layout PT-E-HIP-RX Receiver 5. Transmitter Unit Panel

More information

5006 Centrex AuxBox. Call Recording for Meridian Digital Centrex Telephones. Hardware & Installation Guide

5006 Centrex AuxBox. Call Recording for Meridian Digital Centrex Telephones. Hardware & Installation Guide Call Recording for Meridian Digital Centrex Telephones Hardware & Installation Guide Algo Communication Products Ltd. Customer Support and Sales Tel: 1.877.884.2546 Fax: 604.437.5726 Email: sales@algosolutions.com

More information

Single Port T1/E1 Tap

Single Port T1/E1 Tap Single Port T1/E1 Tap Model 2 CUSTOMER SUPPORT INFORMATION To order or for a technical information support: Phone: +33 3 88 10 18 30 or Fax: +33 3 88 10 18 35 Mail order: COMCRAFT 2, rue de la Mairie 67203

More information

AXIS T81B22 DC 30W Midspan

AXIS T81B22 DC 30W Midspan INSTALLATION GUIDE AXIS T81B22 DC 30W Midspan ENGLISH About this Document This document includes instructions for installing AXIS T81B22 on your network. Previous experience of networking will be beneficial

More information

Portable Bluetooth Speaker. Quick Start Guide. Model: BTS201

Portable Bluetooth Speaker. Quick Start Guide. Model: BTS201 Portable Bluetooth Speaker Quick Start Guide Model: BTS201 Disclaimer All the information, design and specifications contained in this manual were correct at the time of publication. However, as the product

More information

3M Wrist Strap and Footwear Tester 740. User s Guide

3M Wrist Strap and Footwear Tester 740. User s Guide 3M Wrist Strap and Footwear Tester 740 User s Guide Table of Contents Section Page Safety Information...3 1.0 General...4 2.0 Description...4 3.0 Operation...5 4.0 Wall Mounting...5 5.0 Wrist Strap Test...6

More information

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation Stand Alone POTS Fiber Optic System P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit Description & Installation Printed in USA 09/11 TO466 Rev. A Table of Contents Page 1.0 SCOPE 2 2.0 PRODUCT

More information

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

6 & 12 Volt Battery and Systems Tester with 100 Amp Load 6 & 12 Volt Battery and Systems Tester with 100 Amp Load Form No. 841-731 -000 DESCRIPTION This Load Tester tests 6 or 12 volt automotive-size lead-acid batteries under load. It will also test 6 or 12

More information

2 X 250Watt Class D Audio Amplifier Board IRS2092 User s Guide

2 X 250Watt Class D Audio Amplifier Board IRS2092 User s Guide 2 X 250Watt Class D Audio Amplifier Board IRS2092 User s Guide 2004-2013 Sure Electronics Inc. AA-AB32291_Ver1.0 2 X 250Watt Class D Audio Amplifier Board IR2092 Note: Please read this manual carefully

More information

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...

More information

User Manual. September 18, 2007. Copyright 2004-2007 Thomson. All rights reserved.

User Manual. September 18, 2007. Copyright 2004-2007 Thomson. All rights reserved. User Manual September 18, 2007 Copyright 2004-2007 Thomson. All rights reserved. Notices and Warranties Notices & Warraties Copyright Regulations It is illegal for anyone to violate any of the rights provided

More information

Mini-HDMI Series MINIATURE MULTIMODE FIBER OPTIC HDMI TRANSMISSION SYSTEM

Mini-HDMI Series MINIATURE MULTIMODE FIBER OPTIC HDMI TRANSMISSION SYSTEM Mini-HDMI Series MINIATURE MULTIMODE FIBER OPTIC HDMI TRANSMISSION SYSTEM BCI reserves the right to make changes to the products described herein without prior notice or consent. No liability is assumed

More information

PC Tab Security System INSTRUCTION MANUAL

PC Tab Security System INSTRUCTION MANUAL PC Tab Security System INSTRUCTION MANUAL This manual is intended as a Quick Start manual covering the basic functions that have been enabled on the alarm panel. The alarm panel is capable of extensive

More information

KVM - DVI, USB 2.0, Cat 5 Extender

KVM - DVI, USB 2.0, Cat 5 Extender KVM - DVI, USB 2.0, Cat 5 Extender 330 feet (100 meters) EL5100 User Guide Powered by Thank you for purchasing the KVM - DVI, USB 2.0, Cat 5 Extender 330 feet (100 meters) Please read this guide thoroughly.

More information

Active Speaker System LX523 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Active Speaker System with remote input LX523. User Manual & Installation Guide

Active Speaker System LX523 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Active Speaker System with remote input LX523. User Manual & Installation Guide Active Speaker System LX523 AUDAC PROFESSIONAL AUDIO EQUIPMENT Active Speaker System with remote input LX523 User Manual & Installation Guide AUDAC PROFESSIONAL AUDIO EQUIPMENT User Manual & Installation

More information

USER S MANUAL. MaxPower 400-600 UPS. Uninterruptible Power System 28-2MAXPO0018

USER S MANUAL. MaxPower 400-600 UPS. Uninterruptible Power System 28-2MAXPO0018 USER S MANUAL MaxPower 400-600 UPS Uninterruptible Power System 28-2MAXPO0018 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for models MaxPower 400 and

More information

Contents. Safety Warnings... 1

Contents. Safety Warnings... 1 Contents Safety Warnings... 1 Unpacking the GQ600... 1 Introduction... 2 GQ600 Filter Characteristics... 2 1/3 Octave Centre Frequencies... 4 Front Panel Functions... 5 Rear Panel Functions... 6 Specifications...

More information

Benchtop Computer Monitor Generator

Benchtop Computer Monitor Generator Model: 1280B Benchtop Computer Monitor Generator USER MANUAL Safety Summary The following safety precautions apply to both operating and maintenance personnel and must be observed during all phases of

More information

eela-audio EA916 Journalist Unit USB Audio module with Telephone Hybrid User manual

eela-audio EA916 Journalist Unit USB Audio module with Telephone Hybrid User manual eela-audio EA916 Journalist Unit USB Audio module with Telephone Hybrid User manual EA Broadcast / Eela Audio, Het Riet 8 A, 5431NM Cuijk, The Netherlands http://www.eela-audio.com e-mail: sales@eela-audio.com

More information

1080P. Extender for HDMI over one CAT5. GTV-HDBT-CAT5 User Manual. gefentv.com

1080P. Extender for HDMI over one CAT5. GTV-HDBT-CAT5 User Manual. gefentv.com 1080P Extender for HDMI over one CAT5 GTV-HDBT-CAT5 User Manual gefentv.com ASKING FOR ASSISTANCE Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours:

More information

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL 162 CB CABLE TRACER Filter Probe & Tone Generator INSTRUCTION MANUAL INDEX PAGE 1. INTRODUCTION... 1 2. FILTER PROBE... 1-3 3. TONE GENERATOR... 3-6 4. SPECIFICATION... 7-8 5. MAINTENANCE... 8 1. INTRODUCTION

More information

Caller-ID on your TV!

Caller-ID on your TV! TM Caller-ID on your TV! User s Manual and Installation Guide Copyright 1998 NetMedia Inc., All rights reserved. Rev. 061898 Thank you for your purchase of Caller-TV! You are now ready to enjoy the convenience

More information

64-CHANNEL INTEGRATED AMPLIFIER

64-CHANNEL INTEGRATED AMPLIFIER Panasonic 64-CHANNEL INTEGRATED AMPLIFIER Operating Instructions P/N: SU-MED640E Caution for AC main lead FOR YOUR SAFETY, PLEASE READ THE FOLLOWING TEXT CAREFULLY This product is equipped with 2 types

More information

User Guide. HDMI Active Cable Extender. DVI-7370c

User Guide. HDMI Active Cable Extender. DVI-7370c User Guide HDMI Active Cable Extender DVI-7370c TABLE OF CONTENTS SECTION PAGE PRODUCT SAFETY...1 PRODUCT LIABILITY...1 1.0 INTRODUCTION...2 2.0 SPECIFICATIONS...3 3.0 PACKAGE CONTENTS...4 4.0 CONNECTING

More information

User Manual (English)

User Manual (English) User Manual (English) Table of Contents General Safety Information...2 Fueltank UNO Components...3 Charging the Fueltank UNO...4 Using the Fueltank UNO...5 Power Saving Mode...6 Checking the Fueltank UNO

More information

Extender for HDMI 1.3 over CAT6. GTV-HDMI1.3-CAT6 User Manual. www.gefentv.com

Extender for HDMI 1.3 over CAT6. GTV-HDMI1.3-CAT6 User Manual. www.gefentv.com Extender for HDMI 1.3 over CAT6 GTV-HDMI1.3-CAT6 User Manual www.gefentv.com ASKING FOR ASSISTANCE Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours:

More information

Generating Element. Frequency Response. Polar Pattern. Impedance. Output Level

Generating Element. Frequency Response. Polar Pattern. Impedance. Output Level Generating Element Frequency Response Polar Pattern Impedance Output Level Weight Pro 7: Dynamic Pro 7 ic: ic Electret Pro 7: 100 Hz - 12 khz Pro 7 ic: 35 Hz - 12 khz Pro 7: Heil Cardioid Pro 7 ic: Cardioid

More information

V-2901 UNIVERSAL DOOR ANSWERING SYSTEM

V-2901 UNIVERSAL DOOR ANSWERING SYSTEM VSP-V-2901 Issue 6 V-2901 UNIVERSAL DOOR ANSWERING SYSTEM INTRODUCTI The V-2901 is a Universal Door Answering System for use with any single line telephone, electronic or 1A2 key system, or PABX. These

More information

ZC-24DO CANopen I/O Module: 24 Digital Outputs

ZC-24DO CANopen I/O Module: 24 Digital Outputs Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches

More information

Installation & User Manual

Installation & User Manual Messager USB Installation & User Manual Note: All units support MP3 playback of up to 128Kbps @ 48KHz. Units with serial numbers starting with 15 or above will support the addition of WAV playback done

More information

MCR1900 Media Converter 19-Slot Chassis

MCR1900 Media Converter 19-Slot Chassis MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the

More information

User guide Conference phone Konftel 100

User guide Conference phone Konftel 100 User guide Conference phone Konftel 100 I Español I Français Conference phones for every situation This package includes the following items: 1 pc User Guide 1 pc Conference Phone 1 pc Power supply 1 pc

More information

Contents. 2 NP560-NP562 Installation Guide YML821 Rev1

Contents. 2 NP560-NP562 Installation Guide YML821 Rev1 Contents Introduction...4 Package Contents...5 Installing the NetComm Indoor Wireless Booster (NP560/NP562)...6 Electrical Specification...8 Appendix A: Registration and Warranty Information...9 2 NP560-NP562

More information