MVX-Series Diesel Engine Shut Down Valves (Cable Operated Closure/Integral Reset Lever Types)



Similar documents
MVX-Series Diesel Engine Air Shut Down Valves

MPX-Series Diesel Engine Shut Down Valves (Manual Reset / Air Pressure and Manual Closure Options)

SELECTION, APPLICATION & MAINTENANCE

SELECTION, APPLICATION & MAINTENANCE

SELECTION, APPLICATION AND MAINTENANCE

SELECTION, APPLICATION AND MAINTENANCE

World proven safety solutions for diesel engines

SELECTION, APPLICATION AND MAINTENANCE

RODADEACO. Diesel Engine Air Intake Shutoff Valves. Model RDS1 Swing Gate Valve. by AMOT. Overview. Typical Applications. Key Features and Benefits

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

Toroidal Conductivity Sensor

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Diesel Engine Exhaust Spark Arrestors Selection, Application and Maintenance

Operators manual Basic water heater

Baumann Way Bronze or Stainless Steel Control Valve

Turbocharger system components, servicing

Coolflo Safe Touch Shower Mixing Valve ST20015CP

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250 Single Wheel 4WD Ford F350 Dually 4WD (2011 F350 Single Wheel 4WD use p/n 6113)

Assembly and instructions

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250/F-350 Single Wheel 2WD Ford F350 Dually 2WD IMPORTANT NOTES

Original Assembly Guide

INSTALLATION INSTRUCTIONS BL-8704

REMOVAL AND INSTALLATION

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

INSTALLATION INSTRUCTIONS MK-8704

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

PRESSURE REDUCING CONTROL VALVE

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

Installation Instructions

Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

Shut-off & Lockout Valves 1/4" to 1-1/2" port size

Installation Instructions

Front axle components, overview

VW GOLF Mk4 TDI FRONT MOUNTING INTERCOOLER INSTALLATION INSTRUCTIONS

Stainless Steel Single and Dual Circulation Kits

K17.11 DOOR BOLTS K17 DOORS

Installation Instructions S

Givare NC-SRS 280 och 880

High Flow High Pressure Solenoid Valve. Double 3/2 N.C. solenoid valve with manual override

Trash Pumps Models: 56200, , 56201, , 56300, , 56301,

BETTIS CONVERSION INSTRUCTIONS TO CONVERT HD SERIES ACTUATORS TO HD-M3, HD-SR-M3 HD-M3HW OR HD-SR-M3HW SERIES PNEUMATIC ACTUATORS

DeZURIK 3-20" BAW AWWA BUTTERFLY VALVES WITH TRANSFER MOLDED SEAT

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

6 Crankcase Ventilation

2 H OW TO ORDER 2 D ESIGN FEATURES 3 P RODUCTS INDEX 35 O VAL FLANGES 35 B LEED 35 C ONDENSING POTS 36 S YPHONS 36 A IR FEED HEADERS

MANDATORY SERVICE BULLETIN

How To Order A Direct Flow Air Cleaner

StackFlowMaster FPD580 TORBAR probe Stack gas metering systems. Measurement made easy. Introduction. For more information

Model 43AP Pneumatic Controller, Style B

Proportional pressure regulators VPPE

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

kymanual or Automatic - it s your Choice

Saferand easierinstallation

F-Series Camera Mounting Accessories

P7100 PUMP INSTALLATION INSTRUCTIONS Diesel Care & Performance Inc

Fixtures - Parts - Accessories to shampoo bowls

Rack installation instructions

FIRE FIGHTING MANUAL AND REMOTE-CONTROLLED. Simple cabling just 2 power lines. Common Electronic Optimal reach

Fleetguard CS41018 SpiraTec Centrifuge Rotor Installation Instructions

V47 Series Temperature Actuated Modulating Water Valves

Stainless Steel Valves For the Sanitary Industries

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions

Richter Twin Piston Quarter-turn Actuators

Triac Printed Circuit Board Replacement

Aprilia.no. RS Eng.6M

Two most common lock nut groups: 1-Prevailing Torque Type Lock Nuts:

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

FEATURES. ! Sealing to IP68 (fully waterproof) Infra-red optical navigation technology

Installation, Maintenance, & Repair Series 4000B/LF4000B

series Materials Body: 1/2, 3/4 and 1 : dezincification resistant alloy brass EN CW617N

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

Typical Aluminum GFM Mass Flow Meter

STABITHERM INSTALLATION & SERVICE BOOKLET

HIROSE ELECTRIC U.S.A. Fiber Optic VAR July, 2015

INSTALLATION INSTRUCTIONS

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

How To Replace A Reverse Osmosis Water Tank

Eliminator Vented Disc Brake Owners Manual

ANOISON HPQN SERIES HPQN CONNECTORS INTERFACE DIMENSIONS. Description. Interface Dimensions 21 Characteristics

High Flow Air Cleaner Assembly

Flue Options. Ace Finest Finest Gold Best 30/40/50/60 Best 80. Flue Options Flue Options Flue Options Flue Options

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

IOMaster FPD510 Compact integral orifice flowmeter. Low-cost measurement of small flow rates

Electromagnetic Flow Meter

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

Unit 24: Applications of Pneumatics and Hydraulics

PLUMBING CARE AND REPAIR

Transcription:

MVX-Series Diesel Engine Shut Down Valves (Cable Operated Closure/Integral Reset Lever Types) Selection, pplication and Maintenance Valve Numbers MVX-301 MVX-302 MVX-303 MVX-501 MVX-502 MVX-503 MVX-801 MVX-802 MVX-803

DESCRIPTION a range of mechanically actuated diesel engine air intake closure valves based on standard Chalwyn 3, 5 and 8 butterfly valves. Suitable for both hazardous and non-hazardous area applications where a cable operated stop control combined with a valve mounted reset lever is required. available in basic flange mounted form or fitted with hose adaptors or an integral flame trap housing. ody and disc manufactured in corrosion resistant hard anodised aluminium with PtFE coating. Spindle and mechanism made from 316 stainless steel. Typical rrangement: Valve Types MVX-301, MVX-501 and MVX-801 PUSH Type Stop utton Reset Lever Optional Hose daptors Cable Length Options - see under Selection C1 C2 (min) C2 (max) Typical rrangement: Valve Types MVX-302, MVX-502 and MVX-802 PUSH Type Stop utton Reset Lever Cable Length to suit installation Cable Length Options - see under Selection Optional Hose daptor (one each side) C1 C2 (min) C2(max) 2

Typical rrangement: Valve Types MVX-303, MVX-503 and MVX-803 PULL Type Manual Stop Reset Lever Cable Length Options - see under Selection Optional Hose daptor (one each side) C1 C2(min) C2(max) Main Dimensions (mm) Valve Types Nominal ore Diameter C 1 C 2 minimum & maximum MVX-301 MVX-302 MVX-303 76 (3 ) 190.0 190.0 223.0 111.5 37.5 82.5 to 112.5 MVX-501 MVX-502 MVX-503 127 (5 ) 246.0 246.0 279.0 167.0 45.5 102.0 to 157.5 MVX-801 MVX-802 MVX-803 203 (8 ) 346.5 346.5 377.5 257.0 56.0 136.5 to 185.5 Note: Maximum temperature of the engine intake air at the MVX valve not to exceed 150 C. (See also installation - page 5). 3

SELECTION Determine the size and position of the MVX valve to be installed. within the various constraints imposed by the application, the valve should be as generously sized as possible Check that the valve can be positioned such that the reset lever will be easily and safely accessible and that a reasonably straight run is available for the shut down cable. Select the cable length required from the options listed below. Remote Push utton and Cable options for use with PULL Cable ssembly Options (to suit valves Handle RTD-100 (to suit valves MVX-301/302, MVX-501/502 or MVX- MVX-303, MVX-503, or MVX-803) 801/802) assembly part No. length (meters) rc--100 1.0 rc-150 1.5 rc-200 2.0 rc-300 3.0 Select the required length of the manual shut down cable from the table. alternative lengths may be available on request. Cable part No. length (meters) ClD-100 1.0 ClD-150 1.5 ClD-200 2.0 ClD-300 3.0 Select the required length of the manual shut down cable from the table. alternative lengths may be available on request. also order handle rtd-100. If the valve is to be fitted into a hose as opposed to flange mounted, suitable hose adaptors may be selected from the table below for ordering with the valve. Hose daptor Options 76mm (3") ore Valves adaptor to Suit hose ore Part Number mm (inches) hax-320 38 (1 1 / 2 ) hax-322 44.5 (1 3 / 4 ) hax-301 51 (2) hax-302 54 (2 1 / 8 ) hax-303 57 (2 1 / 4 ) hax-304 60 (2 3 / 8 ) hax-305 63.5 (2 1 / 2 ) hax-306 67 (2 5 / 8 ) hax-307 70 (2 3 / 4 ) hax-308 73 (2 7 / 8 ) hax-309 76 (3) hax-312 82.5 (3 1 / 4 ) hax-314 89 (3 1 / 2 ) hax-319 102 (4) 127mm (5") ore Valves adaptor to Suit hose ore Part Number mm (inches) hax-501 89 (3 1 / 2 ) hax-502 92 (3 5 / 8 ) hax-503 95 (3 3 / 4 ) hax-504 98 (3 7 / 8 ) hax-505 102 (4) hax-506 105 (4 1 / 8 ) hax-507 108 (4 1 / 4 ) hax-508 111 (4 3 / 8 ) hax-509 114 (4 1 / 2 ) hax-510 117.5 (4 5 / 8 ) hax-511 121 (4 3 / 4 ) hax-512 124 (4 7 / 8 ) hax-513 127 (5) hax-518 140 (5 1 / 2 ) hax-523 152 (6) 203mm (8") ore Valves adaptor to Suit hose ore Part Number mm (inches) hax-807 178 (7) hax-808 203 (8) 4

INSTLLTION 1. in the case of a naturally aspirated engine, the Chalwyn MVX shut down valve should generally be fitted as close to the engine air intake manifold as possible. if an intake flame trap is also fitted, the MVX valve must be installed upstream (air cleaner side) of the flame trap. 2. to avoid excessively high intake air temperatures at the MVX valve when fitted to a turbocharged engine, it may be necessary to fit the MVX valve either upstream of the turbocharger or downstream of the intercooler (where fitted). again, if an air intake flametrap is also fitted, the valve must be installed upstream of the flametrap. 3. where more than one MVX valve is installed on an engine, as in the case of an engine with multiple intake pipes, the shut down valves must be arranged to all close simultaneously. intake ports must be sealed and replaced by an external breather system venting either to atmosphere or to the intake system upstream of the shut down valve. External breather system kits for various engine types are available from Chalwyn. 8. For values with the pull handle cable operated manual shut down, fit the t handle assembly rtd-100 through a suitable Ø20mm (3/4"dia) hole in a bulkhead or mounting bracket as follows. release the handle locknut. remove the handle,handle locknut and upper locknut and washer. thread handle body through the bulkhead/bracket. refit upper locknut and washer. adjust lower and upper locknuts to position handle and tighten. refit handle locknut and handle. tighten locknut. 4. the valve may be installed either horizontally or vertically. 5. if hose adaptors are used, the mating hose should be of a reinforced type, provide adequate support for the valve and prevent excessive vibration. if necessary, additional support brackets mounted from the engine should be considered. 6. Particular care must be taken to ensure the integrity of the intake pipework between the Chalwyn valve and intake manifold. ideally metal pipework should be used and any gaps kept as short as possible, (taking into account any relative movement) and closed by reinforced hose. the possibility of a hose collapse on closure of the shut down valve must be avoided. 7. any engine crankcase breather connections into the intake system between the MVX valve and engine, or any internal crankcase breather arrangement venting directly into the engine T HNDLE HNDLE LOCKNUT ULKHED or MOUNTING RCKET HNDLE ODY STOP CLE UPPER LOCK NUT LOWER LOCK NUT 5 SVX ENErgiSED to StoP MoDElS

OPERTION Prior to starting the diesel engine, the MVX valve must be latched open by rotating the reset lever clockwise as far as possible. once latched, the reset lever will remain in the latched open position until manually released by the remote stop button. to carry out an emergency closure of the MVX intake valve to stop the engine, operate the manual stop control. No attempt should then be made to restart the engine until the MVX valve is again latched open. MINTENNCE MONTHLY: Check that the fasteners locating the MVX valve and any associated intake systems or support bracket fasteners are securely tightened. Check that any flexible hoses between the MVX valve and engine are free from damage and suitable for further service. run engine, preferably at low idle. operate the stop button. the engine should stop within a few seconds. if not, check that the shut down cable is properly adjusted and that there are no leaks in the intake system between the MVX valve and the engine. if this does not resolve the problem, remove the MVX valve and return to Chalwyn for further investigation. 6

Chalwyn by MOT www.chalwyn.com a division of roper industries limited UK western way ury St Edmunds Suffolk, ip33 3SZ tel: +44 (0)1284 715739 Fax: +44 (0)1284 715747 US 8824 Fallbrook Drive houston tx 77064 tel: +1 (281) 940 1800 Fax: +1 (281) 668 8802 ChalwyN reserves the right to update this ProDuCt SPECiFiCatioN without Prior NotiCE.