Performing Amplifier Measurements with the Vector Network Analyzer ZVB



Similar documents
Making Spectrum Measurements with Rohde & Schwarz Network Analyzers

Agilent PN RF Component Measurements: Amplifier Measurements Using the Agilent 8753 Network Analyzer. Product Note

Impedance 50 (75 connectors via adapters)

Power Amplifier Gain Compression Measurements

RF Network Analyzer Basics

Basics of RF Amplifier Measurements with the E5072A ENA Series Network Analyzer

One Port Network Analyzer

Network analyzer and spectrum analyzer two in one

R&S ZVB Vector Network Analyzer High measurement speed up to 20 GHz with two or four test ports

Keysight Technologies Understanding the Fundamental Principles of Vector Network Analysis. Application Note

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

R&S ZNBT8 Vector Network Analyzer Specifications

Experiment 7: Familiarization with the Network Analyzer

R&S ZCxxx Millimeter-Wave Converters Specifications

ECE 435 INTRODUCTION TO THE MICROWAVE NETWORK ANALYZER

R&S ZNC Vector Network Analyzer Specifications

Improving Network Analyzer Measurements of Frequency-translating Devices Application Note

R&S ZVA Vector Network Analyzer Specifications

Michael Hiebel. Fundamentals of Vector Network Analysis

A Network Analyzer For Active Components

UNDERSTANDING NOISE PARAMETER MEASUREMENTS (AN )

Optimizing IP3 and ACPR Measurements

Fast and Accurate Test of Mobile Phone Boards

Transfer of Trace Data From R&S Network Analyzer ZVx To Microsoft Excel

R&S ZVA Vector Network Analyzer High performance up to 110 GHz with up to four test ports

Basic of Load Pull Measurements Active and Passive load pull & Harmonic load pull testbench

R&S ZVA Vector Network Analyzer High performance up to 67 GHz with up to four test ports

Understanding the Fundamental Principles of Vector Network Analysis. Application Note Table of Contents. Page

Agilent 8720 Family Microwave Vector Network Analyzers

High Power Amplifier Measurements Using Agilent s Nonlinear Vector Network Analyzer

R&S ZVA-Z75, -Z110, -Z140, -Z170, -Z220, -Z325, -Z500 Converters Quick Start Guide

1. The Slotted Line. ECE 584 Microwave Engineering Laboratory Experiments. Introduction:

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

PLANAR 304/1 Vector Network Analyzer. Operating Manual

A Guide to Calibrating Your Spectrum Analyzer

Software Utility VNA Frequency Converter Leveling Tool Getting Started

Automatic compression measurement using network analyzers

R&S ZVA Vector Network Analyzer High performance up to 110 GHz with up to four test ports

iva Cable & Antenna Analyzer

Agilent 10 Hints for Making Better Network Analyzer Measurements. Application Note B

Network Analyzer Operation

Noise Figure Measurement without a Noise Source on a Vector Network Analyzer

Field Calibration Software

MATRIX TECHNICAL NOTES

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

2. The Vector Network Analyzer

Vector Network Analyzer Techniques to Measure WR340 Waveguide Windows

0HDVXULQJWKHHOHFWULFDOSHUIRUPDQFH FKDUDFWHULVWLFVRI5),)DQGPLFURZDYHVLJQDO SURFHVVLQJFRPSRQHQWV

Group and Phase Delay Measurements with Vector Network Analyzer ZVR

R&S ZNC Vector Network Analyzer Solid performance on a future-oriented platform

AUTOMATIC NETWORK ANALYZER PROCEDURES FOR 5045 KLYSTRON CAVITIES * J.G. Judkins

R&S FSW signal and spectrum analyzer: best in class now up to 50 GHz

S-parameter Simulation and Optimization

Agilent AN 1315 Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note

FREQUENCY RESPONSE ANALYZERS

The Effective Number of Bits (ENOB) of my R&S Digital Oscilloscope Technical Paper

Agilent PN Extending Vector Signal Analysis to 26.5 GHz with 20 MHz Information Bandwidth

Agilent 8753ET/8753ES Network Analyzers

Agilent FieldFox RF Vector Network Analyzer N9923A Quick Reference Guide

Introduction to Network Analyzer Measurements

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Application Note Noise Frequently Asked Questions

Agilent Measuring Noninsertable Devices

Distance-To-Fault (DTF) Measurement in 75 Ohm Systems with the R&S FSH3-TV

Engineering Sciences 151. Electromagnetic Communication Laboratory Assignment 3 Fall Term

Experiments Using the HP8714 RF Network Analyzer

EE 186 LAB 2 FALL Network Analyzer Fundamentals and Two Tone Linearity

Scalar Network Analysis with the HP 8590 Series Spectrum Analyzers Product Overview

RF-Microwaves formulas - 1-port systems

Revision 1.10 April 7, 2015 Method of Implementation (MOI) for 100BASE-TX Ethernet Cable Tests Using Keysight E5071C ENA Option TDR

Agilent De-embedding and Embedding S-Parameter Networks Using a Vector Network Analyzer. Application Note

HP 8753E RF Vector Network Analyzer

A Small, Simple, USB-Powered Vector Network Analyzer Covering 1 khz to 1.3 GHz

Agilent Time Domain Analysis Using a Network Analyzer

Advanced Nonlinear Device Characterization Utilizing New Nonlinear Vector Network Analyzer and X-parameters

DSA800 Series Spectrum Analyzer

Using R&S NRP-Z Power Sensors with Android TM Handheld Devices. Application Note. Products:

Measuring RF Parameters of Networks Bill Leonard NØCU

S-Parameters and Related Quantities Sam Wetterlin 10/20/09

Numerical Parameters Analysis of Boonton 4540 Peak Power Meter

CellAdvisor. JD725A Dual-Port Cable and Antenna Analyzer

Microwave. 6200B series RF and Microwave Test sets.

iva Cable & Antenna Analyzer

Technical Overview with Self-Guided Demonstration

Techniques for Precise Cable and Antenna Measurements in the Field

Mobile Phone Testing using Impedance Tuners

Applying Error Correction to Network Analyzer Measurements. Application Note Table of Contents. Page

How To Use An Hm804X Series Of Power Supplies

R&S ZNB Vector Network Analyzer Leading in speed, dynamic range and ease of operation

Network Analyzer Basics- EE142 Fall 07

Calibration Guide. Agilent Technologies ESG Vector Signal Generator

R&S ZVL Vector Network Analyzer Specifications

Agilent E5063A ENA Series Network Analyzer. 100 khz to 4.5/ 8.5/18 GHz

Vector Network Analyzer Family ZVR

Understanding Mixers Terms Defined, and Measuring Performance

Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics

Spectrum and Power Measurements Using the E6474A Wireless Network Optimization Platform

RF and Microwave Accessories. CD-ROM Catalog. Find the right component for your Rohde & Schwarz test & measurement equipment

Transcription:

Product: Vector Network Analyzer R&S ZVB Performing Amplifier Measurements with the Vector Network Analyzer ZVB Application Note This document describes typical measurements that are required to be made on amplifiers and how the measurement can be implemented on the ZVB Vector Network Analyzer. The document describes the concepts and setups required to perform Gain, Isolation, input impedance measurements, then goes on to describe how more uncommon measurements are made with the ZVB like Harmonics, Stability Factor and compression point. Subject to change Jamie Lunn,.27 EZ54_E

Introduction Contents Introduction... 3 2 Amplifier Measurement Configuration for ZVB... 3 3 S-Parameter Measurements... 3 4 Input Reflection Parameters... 4 5 Transmission Parameters... 6 6 Compression Point... 7 7 Harmonic Measurements... 8 Stability Factor... 9 User Definition of Measurements... 3 AM to PM Conversion Measurement... 4 Power Added Efficiency... 5 2 Typical Set of Measurements... 6 EZ54_E 2 Rohde & Schwarz

Introduction Introduction This document is designed to be a guide to help point the user in the right direction for configuring the ZVB Vector Network Analyzer to make important measurements on amplifiers. For further information please refer to the internal help of the ZVB [ ] or alternatively you can access the help online at the Rohde & Schwarz website, http://www.rohde-schwarz.com/webhelp/zvb/start.htm Text marked with grey highlight indicates either a dedicated button press on the front panel or a selection within the softkey menu at the side of the display. 2 Amplifier Measurement Configuration for ZVB To characterize the 2-Port amplifier, the device should be connected directly to the test ports and 2 of the ZVB, as indicated below. ROHDE&SCHWARZ ZVA 24 VECTOR NETWORK ANALYZER MHz 24GHz 3 4 2 3 S-Parameter Measurements Perform a full 2-Port calibration (TOSM) by either using an appropriate manual calibration kit (e.g. R&S ZV-Z32) or using the R&S ZV-Z5x automatic calibration unit. The ZVB is capable of characterizing the input of a device by measuring its input reflection coefficient. This is realized by an internal reflectometer on each test port that has a dedicated receiver for measuring both the incident power wave or reference power (a) and also the reflected power wave or measured power (b). EZ54_E 3 Rohde & Schwarz

Input Reflection Parameters Incident Wave a Reflected Wave b Port Port 2 Transmitted Wave This measured parameter is displayed on the network analyzer as the S- Parameter, S which is the ratio of the measured power b divided by the reference power a: s b = a2 = a This S-Parameter is called the reflection coefficient Γ, the complex data from this measurement can be formatted in a number of different ways on the ZVB to display the desired result. 4 Input Reflection Parameters The input return loss is calculated from the logarithmic value of the magnitude part of the reflection coefficient Γ. Return Loss = 2log This can be displayed directly on the ZVB with a S trace formatted using the [] selection within the [FORMAT] menu. ( ρ) ρ = Γ Trc S 5 db / Ref db S 5 Cal -5 - -5-2 -25-3 Trace Statistics Min: -7.52 db Max: -4.539 db Pk-Pk: 3.3482 db -35 Ch Start 5 MHz Pwr -2 dbm Stop.5 GHz /2/26, :44 PM EZ54_E 4 Rohde & Schwarz

Input Reflection Parameters A nice feature of the ZVB is the ability to display the statistical analysis of a desired trace. This can be accessed in the [TRACE FUNCTION] x2 menu and then [Trace Statistics], within this menu you can then choose the required read-out (Min/Max/Peak-Peak etc). *Hint, when using Trace Statistics you can define an evaluation range for which the analysis is to be performed, therefore giving the characteristics over a defined bandwidth. The reflection coefficient can also be displayed in a VSWR format (Voltage Standing Wave Ratio or more commonly SWR). This is the ratio of the maximum to minimum values of the standing wave pattern that is created when signals are reflected on a transmission line. VSWR = Vmax Vmin = + ρ ρ This can be displayed directly on the ZVB with a S trace formatted using the [SWR] selection within the [FORMAT] menu. Trc S SWR.5 U / Ref U S 5.5 Cal 5. 4.5 4. 3.5 3. Trace Statistics Min:.396 U Max:.4889 U Pk-Pk:.793 U 2.5 2..5. Ch Start 5 MHz Pwr -2 dbm Stop.5 GHz /2/26, :46 PM The reflection coefficient can also be displayed in a complex input impedance format that is mapped directly onto the smith chart. This can be accessed using the [Smith] selection within the [FORMAT] menu. EZ54_E 5 Rohde & Schwarz

Transmission Parameters Trc S Smith Ref U Cal S.5 Mkr. GHz 6.956 Ω j4.97 Ω 2 2.383 nh 5 Mkr.2.5 2 5-5 -.5-2 Ch Start 5 MHz Pwr -2 dbm Stop.5 GHz /2/26, :49 PM - 5 Transmission Parameters In addition to reflection measurements, the forward transmission coefficient can be measured by referencing the transmitted power on the measured power () receiver of Port 2 to the reference power (a) receiver of Port. b 2 s 2 = a 2 = a The ratio of these parameters will give the forward transmission coefficient (S 2 ) which can be converted into the transmission gain by taking the logarithmic value of its magnitude: Gain (db) = 2 Log The ZVB is also capable of performing a reverse sweep measurement, so that the stimulus can be applied from Port 2 and the reverse transmission coefficient can be found, commonly known as the isolation characteristics. s b 2 = a = a2 The reverse transmission coefficient can be measured by referencing the transmitted power on the measured power (b) receiver of Port, to the reference power (a2) receiver of Port 2. S 2 Isolation (db) = - 2 Log Both the Gain and Isolation can be displayed directly on the ZVB using the relevant S-Parameters S 2 & S 2 and formatting these using the [] selection within the [FORMAT] menu. S 2 EZ54_E 6 Rohde & Schwarz

Compression Point Trc Trc2 S2 S2 db / db / Ref - db Ref - db Cal Ca? Cal Off S2 3 Mkr. GHz Mkr 2.63 db 2 - Trace Statistics Min: 9.5948 db Max: 2.498 db Pk-Pk:.897 db -2-3 Mkr -4-5 Mkr. GHz -34.465 db Ch Start 5 MHz Pwr -2 dbm Stop.5 GHz /2/26, 4:52 PM 6 Compression Point Compression point is a measure of linearity of a device. It is always defined at a specified value of which can be referenced to the input or the output power that is present at that device. For instance the db compression point of an amplifier defines the output level at which the amplifier s gain is db less than the small signal gain, or is compressed by db. P db db On the ZVB it is possible to not only sweep the measurement versus frequency, but you can also choose power as the swept variable. The ZVB has a very large sweep range available from its generators (typically 6dB), it does this completely electronically without the need for mechanical step attenuators. This makes the ZVB the perfect instrument to measure nonlinearities and compression of an active device. EZ54_E 7 Rohde & Schwarz

Compression Point Source_Power a db / Ref dbm a 2 Min -48.44 dbm -47.476 dbm Max 7.62 dbm 5.44 dbm Max - -2-3 >6dB Power Sweep Range -4 Min -5-6 Power Sweep with Freq = GHz Ch Start -5 dbm Freq GHz Stop 2 dbm /28/26, 4:6 PM As the S-Parameter S 2 is the ratio of the output power over input power, then this is precisely what is needed to be displayed on the ZVB. Compressio n P db = ( or in) @ ( small signal) P out Gain db By adding a second channel it is possible to perform a completely separate set of measurements, this new channel can be configured to perform a power sweep. Pressing [CHAN SELECT] and [Add Channel + Trace + Diag Area] will create a new channel, then in the [Sweep] menu select [Power], and choose the fixed frequency at which the power is to be swept over. There is an automatic compression point marker available, this can be found be pressing [TRACE FUNCT] x2 and then choosing [Trace Statistics] and [Compression Point] EZ54_E 8 Rohde & Schwarz

Compression Point Trc S2 2 db / Ref 2 db S2 2 8 6 4 2 8 6 4 Ca? Cmp Trace Statistics Cmp In: -9.9 dbm Cmp Out: 9.7 dbm Ch Start -45 dbm Freq GHz Stop dbm Trc2 5 db / Ref -5 dbm 5 db -5 - -5-2 -25-3 -35 2 Ch Start -45 dbm Freq GHz Stop dbm /3/26, 2: PM *Hint, to select more than one compression point value use additional channels with a power sweep at different fixed frequencies. When performing absolute power measurements like compression point, it is important to have the correct power level feeding into the DUT, it is recommended to perform a Power Calibration. This can be performed easily with the R&S NRP power sensor and the NRP-Z4 USB cable connected directly to the ZVB, alternatively a SCPI compliant power meter connected to the IEEE bus may also be used if you have the ZVAB-B44 option (USB- GPIB converter). When the channel is configured correctly, select [CAL] and choose [Start Power Cal], you can then perform a [Source Power Cal] with the NRP power sensor connected directly to the end of the cable on Port. In addition, the receiver (and cable loss) on Port 2 can also be calibrated by simply connecting the calibrated source of Port to the receiver of Port 2, this can be done using the [Receiver Power Cal]. EZ54_E 9 Rohde & Schwarz

Harmonic Measurements ROHDE&SCHWARZ ZVA 24 VECTOR NETWORK ANALYZER MHz 24GHz 3 4 2 NRP-Z NRP-Z4 You can change the parameters that are used during the measurement sweep by the [Modify Settings] tab within the Power Cal menu. For more information on this and power calibration in general, please refer to the ZVB help. 7 Harmonic Measurements Due to non-linearities in active devices as an amplifier moves out of its linear region and gets close to compression, distortion effects will start to become apparent. One of these distortion effects will manifest itself into power at the harmonics, i.e. additional frequency components at multiples of the fundamental frequency. P f F f H2 f H3 f The flexible hardware concept of the ZVB makes it possible to introduce a frequency offset between the generators and the receivers of the instrument (requires ZVB-K3 option). This gives the ability to stimulate the device at the fundamental frequency and then measure the transmission response from the device at a different (multiples of) frequency. EZ54_E Rohde & Schwarz

Stability Factor Fundamental Harmonic_2nd Harmonic_3rd db / db / db / Ref dbm Ref dbm Ref dbm Ch Ch2 Ch3 Mkr - Mkr Mkr -2-3 -4-5 Mkr -. dbm.67 dbm Mkr -. dbm -9.328 dbm Mkr -. dbm -7.729 dbm -6-7 Ch Ch2 H2 Ch3 H3 Start -45 dbm Start -45 dbm Start -45 dbm /7/26, :42 AM Freq Freq Freq GHz GHz GHz Stop dbm Stop dbm Stop dbm Create a new channel by pressing [CHAN SELECT] and [Add Channel + Trace + Diag Area], and now assign the traces containing the harmonic values to this channel. Select [MODE] and [Harmonics], then choose either 2 nd Harmonic, 3 rd Harmonic or another integer multiple of fo from the soft key menu. Multiple harmonic traces can be created by adding a new channel for each, [CHAN SELECT] and [Add Channel + Trace]. As with the Compression point measurement, it is important to calibrate the correct power levels at all of the harmonic frequencies to be measured on the reference receiver [] of Port 2. In the [MODE] menu select [Harmonics] and, [Harmonics Power Cal], it is then possible to calibrate the ZVB in much the same way as before. 8 Stability Factor Amplifiers have the ability to become unstable at certain operating conditions. This can cause the device to start to oscillate, resulting in spurious frequencies to be produced at the output. Spurious frequencies are those that are not associated with or related to the fundamental frequency. Stability refers to the amplifiers ability to not produce any of these spurious oscillations. The stability factor can be defined in a number of ways, the ZVB allows for three methods of stability factor to be calculated automatically, and are defined from the small signal 2 Port S-Parameters of the device. A linear circuit is said to be unconditionally stable if no combination of passive source or load can cause the circuit to oscillate. Conditionally stable refers to a circuit that is stable when its input and output impedance are matched to the correct impedance, but under mismatch conditions their may a combination of input and output impedance that causes the device to oscillate. The stability factors Κ, µ and µ 2 are real functions of the (complex) S-parameters, defined as follows: EZ54_E Rohde & Schwarz

Stability Factor where S xx denotes the complex conjugate of S xx. The K-factor provides a necessary condition for unconditional stability: A circuit is unconditionally stable if K> and an additional condition is met. The additional condition can be tested by means of the stability factors µ and µ2. The µ and µ2 factors both provide a necessary and sufficient condition for unconditional stability: The conditions µ> or µ2> are both equivalent to unconditional stability. This means that µ and µ2 provide direct insight into the degree of stability or potential instability of linear circuits. EZ54_E 2 Rohde & Schwarz

User Definition of Measurements 9 User Definition of Measurements The ZVB has a very powerful equation editor allowing the user to configure almost any arbitrary formula for further processing of data. Even very complex derived quantities are displayed in real time along with the standard S- Parameters. One possible use for this could be to measure the Maximum Available Gain (MAG) from a device when the K factor is greater than. S2 2 MAG = K K S 2 A dedicated trace can be configured to display the required user defined math function as shown, below. The math editor can be found in the [TRACE FUNCT] menu and then [User Def Math] EZ54_E 3 Rohde & Schwarz

AM to PM Conversion Measurement AM to PM Conversion Measurement Measurements of Amplitude Modulation to Phase Modulation are characteristics of non-linear behavior of amplifiers. They give a measure of the unwanted phase distortion that may occur in an amplitude varying system. AM to PM conversion is defined as the change in output phase for a db increment in the input power to the amplifier, which is expressed in degrees/db. The AM to PM conversion can be measured easily on the ZVB by using the power sweep mode. As before when configuring the compression measurement press [CHAN SELECT] and [Add Channel + Trace] create a new channel, then in the [Sweep] menu select [Power], and choose the fixed frequency at which the power is to be swept over. You can then choose a point at which the amplifier is to be used and by using the delta marker select db, and read off the value of phase change. In this case for -5dBm input power the AM to PM conversion is.5º/db. Trc S2 Phase / Ref -8.5 S2 Trc2 S2 2 db / Ref 2 db 8 Trace Statistics Cmp In: -. dbm Cmp Out: -.4 dbm Cmp 6 4 Ref Mkr 2 Ref -5. dbm -8.47 Mkr. dbm.52-2 -4-6 Ch Start -45 dbm Freq GHz Stop dbm /6/26, 3:5 PM EZ54_E 4 Rohde & Schwarz

Power Added Efficiency Power Added Efficiency Another feature of the ZVB is the ability to measure DC voltages from the two DC Measurements inputs located at the rear of the instrument (±V & ±V ranges available). These inputs allow a DC voltage to be sampled and either displayed real-time on the ZVB or the result of DC quantities derived from the user-defined equation editor. To complement this feature the ZVB also has a built-in function to allow the real time characterization of the Power Added Efficiency (PAE) of an amplifier. The PAE is defined as the ratio of the difference of the output and input signal to the DC power that the device is consuming: PAE = ( Pout( db) Pin( db) This feature can be accessed in the [MEAS] followed by [DC Meas] and [PAE]. P DC ) ROHDE&SCHWARZ ZVA 24 VECTOR NETWORK ANALYZER MHz 24GHz DC Measurement Inputs 3 4 2 R SENSE P IN P OUT V Connection to the DC measurement inputs on the rear of the ZVB can be made with the optional ZV-Z7 cable. EZ54_E 5 Rohde & Schwarz

Typical Set of Measurements 2 Typical Set of Measurements Input_Ret_Lo... S 2 db / Ref db S -2-4 -6-8 - -2-4 -6-8 Cal Trace Statistics: Input_Ret_Loss S Min: -7.2497 db Max: -4.2372 db Pk-Pk: 3.24 db Fwd_Gain Rev_Isolatio... S2 5 4 3 2 - -2-3 S2 S2 db / Ref db db / Ref db Trace Statistics: Fwd_Gain S2 Min: 9.5557 db Max: 2.5497 db Pk-Pk:.9939 db. GHz -24.452 db Isolation Cal Cal 2 Ch Start 5 MHz Pwr -2 dbm Stop.5 GHz Compression S2 2 db / Ref 2 db S2 Cmp 2 8 6 4 2 8 6 4 Cal Trace Statistics:Compression S2 Cmp In: -.2 dbm Cmp Out: 9.6 dbm Ch2 Start -45 dbm Freq GHz Stop dbm /28/26, 3:39 PM 3 Ch Start 5 MHz Pwr -2 dbm Stop.5 GHz Fundamental Harmonc_2nd Harmonic_3rd - -3-5 -7 Ch3 Ch4 Ch5 H2 H3 Start Start Start -45 dbm Freq -45 dbm Freq -45 dbm Freq db / db / db / GHz GHz GHz Ref dbm Ref dbm Ref dbm Ch3 Ch4 Ch5 Stop Stop Stop 4 dbm dbm dbm EZ54_E 6 Rohde & Schwarz

Additional Information 3 Additional Information This Application Note is updated from time to time. Please visit the website EZ54 to download the latest versions. Please send any comments or suggestions about this application note to sales@rsuk.rohde-schwarz.com. 4 Ordering Information Listed are all R&S ZVB network analyzers and most important options. Of course, accessories like test cables, or manual and automatic calibration kits are available in addition. There is also a wide variety of R&S NRP test heads for power measurement and power calibration. For details, please contact your local R&S sales office, or the R&S web site. Order No. Type Designation 45..4 R&S ZVB4 Vector Network Analyzer, 2 Ports, 4 GHz 45..5 R&S ZVB4 Vector Network Analyzer, 3 Ports, 4 GHz 45..6 R&S ZVB4 Vector Network Analyzer, 4 Ports, 4 GHz 45..8 R&S ZVB8 Vector Network Analyzer, 2 Ports, 8 GHz 45..9 R&S ZVB8 Vector Network Analyzer, 3 Ports, 8 GHz 45.. R&S ZVB8 Vector Network Analyzer, 4 Ports, 8 GHz 45..2 R&S ZVB2 Vector Network Analyzer, 2 Ports, 2 GHz 45..22 R&S ZVB2 Vector Network Analyzer, 4 Ports, 2 GHz 64.592.2 R&S ZVB-K3 Mixer and Harmonic Measurements 32.5544.2 R&S ZVAB-B44 USB-to-IEC/GPIB Adapter 6.8473.2 VISA I/O BIB. Visa I/O library for instrument control ROHDE & SCHWARZ UK LTD Ancells Business Park, Fleet, Hants, UK GU5 2UZ Telephone +44 252 88888 Fax +44 252 8447. Internet: http://www.rohde-schwarz.com/uk This application note and the supplied programs may only be used subject to the conditions of use set forth in the download area of the Rohde & Schwarz website. EZ54_E 7 Rohde & Schwarz