1 Agilent PSA Series Spectrum Analyzers External Source Control Measurement Personality, Option 215 Technical Overview with Self-Guided Demonstration Expand your PSA Series from spectrum analysis to scaler network analysis. With the Agilent PSA Series external source control measurement personality (Option 215) and an Agilent PSG, or ESG, or MXG signal generator, the PSA Series spectrum analyzers now enable scalar stimulus-response tests up to 50 GHz for component characterization.
2 Empower the PSA Series High-Performance Spectrum Analyzers with the Scalar Network Analysis Capability Up to 50 GHz Stimulus-response measurements are a necessity in component and subsystem characterization. Typically, most stimulus-response measurements are conducted with network analyzers. However, adding an external source control measurement personality (Option 215) to the Agilent PSA Series spectrum analyzers, along with an Agilent PSG, or ESG, or MXG signal generator 1, can provide single-channel scalar-networkanalysis in addition to all the benefits from a general-purpose spectrum analyzer and a standalone analog or digital signal source. Now, you can use the PSA Series spectrum analyzers not only for analyzing and identifying unknown signals by measuring parameters such as power, frequency, noise, distortion, and modulation quality, but also for characterizing the behavior of components or subsystems including frequency response, conversion loss, insertion loss/gain, and return loss. Key features Perform scalar stimulusresponse measurements up to 50 GHz 2, extending component tests to the millimeter-wave range with minimal extra investment. Characterize a component with the presence of high and low power levels at the same time, such as measurements of passband and block-band of a filter with the instrument s wide dynamic range (up to db on Option 215 s defaulted setting). Eliminate distortions caused by harmonics from swept signal sources when measuring passive devices using the narrow resolution bandwidths (up to 1 Hz with the manual setting). Save time performing component tests with the instrument s easy set up and intuitive user interface. Perform tests on different components with a variety of sweep modes, including standard sweep, harmonic sweep, offset sweep, reverse sweep, and power sweep. Improve the accuracy of the test system providing satisfactory measurements for scattering or S-parameters such as S 11 and S 21 using the normalization and Open/Short calibration. The Agilent PSA Series offers a leading-edge combination of flexibility, speed, accuracy and dynamic range along with powerful one-button measurements and a versatile feature set. Expand the PSA Series to include an external source control capability with the downloadable external source control measurement personality (Option 215). This technical overview includes: Measurement details Demonstrations PSA Series key specifications for the external source control personality Ordering information Related literature All demonstrations use the Agilent E4440A PSA Series with Option 215, Agilent E8257D PSG analog signal generator, and accessories included in the PSA Series Option 015 (6 GHz return loss measurement accessory kit), and an appropriate device under test (DUT). The keystrokes surrounded by [] indicate hard keys while keystrokes surrounded by {} indicate soft keys located on the right edge of the display. Demonstration preparation page 3 Filter test with standard sweep page 5 Amplifier test with harmonic sweep page 7 Amplifier linearity tests with power sweep page 9 Mixer test with offset sweep page 10 Normalization page 12 Open/Short calibration page Refer to "Key Specifications" on page 14 for supported signal generator models and firmware requirements. 2. PSA Option 215 does not support "frequency band crossing". 2
3 Demonstration preparation To perform the following demonstrations, a PSA Series and a PSG-D requires the following configurations. Figure 1a shows demo system set up. The LAN connection between the PSA and the PSG can be made either through a LAN cross-over cable or through the office LAN environment by using two normal LAN cables connected to the PSA and the PSG, respectively. The hardware connection instructions can also be obtained by pressing [Source] {Ext Src Config} {HW Connection Instructions} on the PSA Series (Figure 1b). Product type Model number Required configurations PSA Series E4440A/43A/ Option 215 external source control spectrum analyzer 45A/46A/ measurement personality 47A/48A Instrument firmware version A or later PSG-D Series E8257D/67D Instrument firmware version A or later signal generator "Trigger out" (on rear) PSG "Sweep out" (on rear) "10 MHz out" Trigger Drives each sweep point using the PSA gated sweep trigger source External frequency reference LAN Sweep Drives the start of the PSA sweep using the PSA trigger source "Ext Ref In" PSA "50 ohm feedthrough" "Trigger in" (on rear) "Ext trigger in" (on front) Figure 1a. Set up of the demonstration system Figure 1b. Graphic instructions for the hardware connection on the PSA Series display 3
4 Configure IP addresses Instructions Keystrokes The PSA Series with Option 215 controls the external source through a LAN connection based on the TCP/IP protocol. The TCP/IP protocol can only be established with correct IP addressing. Upon completion of the hardware set up, you need to assign an appropriate IP address to the external source. This section is an example for the IP addressing based on a LAN crossover cable connection between the PSA Series and the PSG. Set IP address and subnet mask On PSA: [System], {Config I/O} {IP on the PSA. Address}, key in [ ], and [Enter]; {Subnet}, key in [ ], and [Enter]. Assign IP address to the PSG. Save the assigned IP address to the PSG. On PSG: [Utility], {GPIB/RS-232/LAN} {LAN Setup} {IP Address} {Clear Text}, key in [ ], and {Enter}. {Proceed With Reconfiguration}, {Confirm Change (Instrument will Reboot)} Set the PSG IP address to the PSA External source control. On PSA: [Source] {Ext Src Config} {IP Address}, key in [ ], and [Enter]. Verify the IP connection. On PSA: [Source] {Ext Src Config} {Show Setup}, you should see information for the external source including its start and stop frequencies. 4
5 Filter tests with standard sweep Filters are one of the most important and most commonly used frequency selective devices. With the external source control capability, you can easily characterize a filter s behavior by using the PSA Series coupled with a supported external source. In this section, we will use a MHz bandpass filter as a DUT to determine its bandwidth, passband ripple, and shape factor. In the standard sweep mode, the PSA Series will sweep synchronically with the PSG at the same start and stop frequencies. Connect the input port of the filter to the PSG RF output, and the output to the PSA RF input as shown in Figure 2. This exercise demonstrates filter characterization for 3 db bandwidth, selectivity, and passband ripple. PSG RF output Figure 2. Set up for filter tests Instructions Preset PSA. Set PSA input as DC couple. Filter (DUT) Keystrokes [Preset] PSA with Option 215 RF input [Input/Output], {RF Coupling}, and toggle to underline DC. Set sweep range from MHz to [FREQUENCY], {Start Freq} [ ] MHz on the PSA. {MHz}, {Stop Freq} [ ] {MHz} Turn on external source control. [Source], {Amplitude}, toggle to underline On. Use Marker functions to determine: 1. Bandwidth ( 3 db) [Marker], {Normal} {Delta Pair}, toggle to underline D, turn the knob to move Marker 1 toward left and stop at 3 db down from Marker 1R; {Delta}, turn the knob to move Marker 1 to right and stop at 0 db. Now the frequency reading after D Mkr1 at the top right of the PSA display show the 3 db bandwidth. See Figure Selectivity or shape factor [Measure] {Meas Off}, [Marker], ( 3 db vs. 60 db) {Normal}, {Delta Pair}, toggle to underline Ref, turn the knob to move the Marker 1R to 3 db below Marker 1 and get the frequency offset reading A (for example: 7 khz); then {Delta Pair}, toggle to underline D, turn the knob to move Marker 1 to 57 db below Marker 1R and get the frequency offset reading B (for example: 8.3 khz). Now, the shape factor of this filter can be calculated as (a+b)/b (for example: (7+8)/7, or 2.1:1). See Figure Passband ripple [SPAN], [20] {khz}, [AMPLITUDE], {Ref Level}, [±] [14] {dbm}, {Scale Div} [1] {db}. See Figure 5 for the measurement result. 5
6 Figure 3. Determining the 3 db bandwidth for a bandpass filter Figure 4. Calculating the filter s shape factor Figure 5. Characterizing flatness or ripple of the filter s passband 6
7 Amplifier harmonic tests with harmonic sweep Amplifiers are the most common active devices. Harmonic distortion is one of the critical characteristics when evaluating the quality of an amplifier. In this section, we will demonstrate how to measure harmonic distortion for an Agilent 8447C amplifier ( MHz) with the harmonic sweep setting in the PSA Series external source control measurement personality. In the harmonic sweep mode, the starting and stopping frequencies of the PSA Series are N times of those of the PSG, where, N (0.1 < N < 10) is the harmonic number. Connect the input port and output port of the amplifier to the PSG RF Output and to the PSA RF Input, respectively (Figure 6). This exercise demonstrates how to test harmonic behaviors of an amplifier. PSG RF output Figure 6. Set up for amplifier harmonic tests Instructions Preset PSA. Amp (DUT) Keystrokes [Preset] PSA with Option 215 RF input Set PSA to sweep from 100 MHz to [FREQUENCY], {Start Freq} [100] {MHz}, 900 MHz. {Stop Freq} [900] {MHz} Turn on external source control. Verify sweep range of the PSG and compare it to that of the PSA. Set PSA to sweep from 300 MHz to 2700 MHz. [Source], {Amplitude}, toggle to underline On. See Figure 7 for the amplifier s frequency response between 100 MHz and 900 MHz. {Ext Src Config} {Show Setup}, you ll see the source information including start frequency = 100 MHz and stop frequency = 900 MHz. [FREQUENCY], {Start Freq} [300] {MHz}, {Stop Freq} [2700] {MHz} Set the 3rd harmonic and activate the [Source] {Config Sweep}, toggle harmonic sweep. {Harmonic} to underline On, then [3] [Enter]. Ensure the external source control is On. Verify sweep range of the PSG and compare it to that of the PSA. [Source], {Amplitude}, toggle to underline On. See Figure 8 for the amplifier s response at range of 300 ~ 2700 MHz to the input signal between 100 MHz and 900 MHz. {Ext Src Config} {Show Setup}, you ll see the source information including start frequency = 100 MHz and stop frequency = 300 MHz. 7
8 Figure 7. Amplifier s frequency response at the fundamental harmonic (N = 1) Figure 8. Amplifier s frequency response at the third harmonic (N = 3) 8
9 Amplifier linearity tests with power sweep Another important parameter in characterizing an amplifier is the gain compression or how the amplifier behaves in saturation. Gain compression limits the amplifier s dynamic range. The power sweep mode in the PSA Series external source control measurement personality enables you to easily measure the gain compression. In this section, we will demonstrate how to perform the CW gain compression measurement. The external source is controlled so that its power output is swept incrementally in a linear fashion as the frequency remains constant. Additionally, the swept gain compression of an amplifier can easily be measured by setting the frequency span to an appropriate range. Connect the input and output ports of an amplifier (ZFL-1000LN-3, from Mini-Circuits) to the RF output of the PSG and the RF input of the PSA Series, respectively (Figure 9). This exercise demonstrates how to determine linearity of an amplifier. PSG RF output Amp (DUT) Figure 9. Set up for amplifier gain compression tests Instructions Preset PSA. Set PSA to Zero span at 750 MHz. Set power sweep at 30 db. Turn on external source control. Readjust the display amplitude level. Keystrokes [Preset] PSA with Option 215 RF input [FREQUENCY], {Center Freq} [750] {MHz}, [SPAN] {Zero Span} [Source], {Config Sweep}, toggle {Power} to underline On, [30] {db}. [Return], toggle {Amplitude} to underline On, [±] [40] {dbm}. [AMPLITUDE], {Ref Level} [10] {dbm}, {Scale/Div} [2] {db} Observe the curve of the output power See Figure 10 for the amplifier s behavior vs. input power of the amplifier (as the when entering the saturation. full span of the input power is set to 30 db, the horizontal axis is translated to 3 db/division). Figure 10. Amplifier s gain compression at a fixed frequency 9
10 Mixer tests with offset sweep Mixers are widely used as frequency translation devices. They provide a signal at the output whose frequency is the sum and difference of the signals on the two inputs. The offset sweep mode, available in the PSA Series external source control measurement personality, allows you to measure behavior of a mixer output level while synchronizing the PSG to sweep with an offset frequency to generate an appropriate intermediate frequency (IF) span. Connect the RF input and IF output of the mixer to the PSG RF output and the PSA RF input, respectively. For the mixer tests we need an additional signal source to generate a CW signal with a fixed frequency as the LO input. Refer to Figure 11 for the test system set up. PSG RF output Figure 11. Set up for mixer tests Instructions RF Mixer (DUT) LO IF Second signal source at a fixed frequency Keystrokes PSA with Option 215 RF input Set the signal generator (II) to generate On the signal generator (II): [Frequency] a 400 MHz and 5 dbm output as the [400] {MHz}, [Amplitude] [5] {dbm} LO signal. Preset PSA. Set PSA start frequency = 100 MHz and stop frequency = 200 MHz. [Preset] [FREQUENCY], {Start Freq} [100] {MHz}, {Stop Freq} [200] {MHz} This exercise demonstrates mixer tests and shows how to determine sweep directions. Turn the offset sweep mode on and set the offset to 400 MHz. Turn on external source control. Verify the PSG sweeps up, i.e., in normal direction. [Source], {Config Sweep}, toggle {Offset} to underline On, [400] {MHz} [Return], toggle {Amplitude} to underline On. See the mixer output as shown in Figure 12. {Ext Src Config} {Show Setup}, you ll see the source information including start frequency = 500 MHz and stop frequency = 600 MHz as shown in Figure 13. Figure 12. Measuring mixer output with normal sweep Figure 13. Source set up status showing the normal sweep (start frequency < start frequency) 10
11 In some use cases, particularly for the mixer tests at the low side, a reverse sweep becomes desirable. By setting up an offset frequency of different values you can control the direction that the PSG sweeps. The PSG sweep frequency and direction are governed by the following equations: Freq source = Abs val [(Freq analyzer + Freq offset Freq point-spacing )/Harmonic] Equation 1 Sweep direction = sgn [(Freq analyzer + Freq offset Freq point-spacing )/Harmonic] Instructions Set PSA start frequency = 100 MHz and stop frequency = 200 MHz. Turn the offset sweep mode on and set the offset to 400 MHz. Turn on external source control. Verify the PSG sweeps Down, i.e., in reverse direction. Keystrokes [FREQUENCY], {Start Freq} [100] {MHz}, {Stop Freq} [200] {MHz} [Source], {Config Sweep}, toggle {Offset} to underline On, [±] [400] {MHz}. [Return], toggle {Amplitude} to underline On. See the mixer output as shown in Figure 14. {Ext Src Config} {Show Setup}, you ll see the source information including start frequency = 300 MHz and stop frequency = 200 MHz as shown in Figure 15. Equation 2 where, Abs val [x] is the absolute value of x, sgn [x] the sign (positive or negative) of x, and the Freq point-spacing is given by the span divided by (number of sweep points 1). In equation (2), the positive sign means the PSG sweeps at the normal direction (start frequency < stop frequency), whereas the negative sign means the reverse direction (start frequency > stop frequency). The following demo shows how to configure a reverse sweep for the hardware set up shown in Figure 11. Figure 15. Source set up status showing the reverse sweep (Note: start frequency > stop frequency) Figure 14. Measuring mixer output with the reverse sweep 11
12 Normalization Normalization is often used in a transmission measurement to correct for systemic frequency errors. The frequency response of the test system must first be measured and then normalization is used to eliminate the frequency response errors caused by the system. To measure the frequency response of the test system, set up the system as desired for the DUT tests. Then relace the DUT with a thru connection (See Figure 16). This exercise demonstrates how to use normalization to correct for systemic frequency errors in a transmission measurement. PSG V incident RF output Figure 16. Set up for normalization Instructions Preset PSA. DUT Through connection With the thru connection connected, measure the frequency response of the test system. Keystrokes [Preset] PSA with Option 215 [Source], {Normalize} Store the frequency response curve {Store Ref (1-> 3)} of the test system as the reference. Vtransmitted RF input Activate the normalization, and observe the active trace is now the ratio of the input to the stored reference. [Source], {Normalize}, toggle {Normalize} to underline On. Reconnect the DUT to the test Note that the units of the reference level system and measure the normalized have changed to db, indicating that it is DUT frequency response. now a relative measurement (Figure 17). Figure 17. Frequency response of the bandpass filter with normalization 12
13 Open/Short calibration The PSA with a tracking source and an external directional coupler or directional bridge enables reflection measurements. Performing reflection measurements allows you to determine some critical characteristics for a device, such as reflection coefficient, return loss, and SWR (standing wave ratio). An Open/ Short calibration is used for reflection measurements and corrects for system frequency response errors. Essentially, this type of calibration is a normalized measurement in which a reference trace is stored in memory and will then be subtracted from later measurement data. A calibration created by measuring both an open and a short is more accurate than using only one or the other. Since the open data and short data are 180 degrees out of phase, their average tends to average out the calibration errors. Figure 18 is a diagrammatic presentation for reflection measurements and the Open/Short calibration. The PSA Series Option 015 (6 GHz return-loss measurement accessory kit) provides the accessory parts, such as directional bridge, short, and coaxial cables, required for reflection measurements and is therefore ideal for the Open/Short calibration. PSG V incident Figure 18. Set up for Open/Short calibration Instructions Preset PSA. Start the Open/Short calibration. Follow the graphical instructions given on the PSA display and Open the bridge output and proceed. Follow the graphical instructions given on the PSA display and apply a Short to the bridge output and proceed. Complete the Open/Short calibration. PSA with Option 215 V reflected Directional bridge Keystrokes [Preset] Open/Short DUT [Source], {Open/Short Cal} {Continue} {Continue} {Done Open/Short Cal} V transmitted This exercise demonstrates how to initiate an Open/Short calibration that helps reduce systemic errors in a reflection measurement. 13
14 Key Specifications PSA Option 215: external source control measurement personality Description Specifications Supplemental information Operating frequency range 3 Hz to 50 GHz PSA mixing bands: (The start/stop frequencies of the Band 0: 3 Hz to 3.05 GHz swept span must be within the same Band 1: 2.85 to 6.6 GHz PSA Series mixing band as shown in Band 2: 6.2 to 13.2 GHz right column) Band 3: 12.8 to 19.2 GHz Band 4: 18.7 to 26.8 GHz Band 5: 26.4 to GHz Band 6: 31.0 to 50 GHz Sweep offset setting range Limited by the source and analyzer operating range Sweep offset setting resolution 1 Hz Harmonic sweep setting range Sweep direction N= 0.1 to 10, where N is the harmonic number Normal, reverse Dynamic range (10 MHz to 3 GHz, input terminated, sample detector, average typ = log, 20 C to 30 C) PSA span PSA RBW Dynamic range 1 MHz 2 khz db 10 MHz 6.8 khz db 100 MHz 20 khz 98.9 db 1000 MHz 68 khz 93.6 db Minimum/maximum power sweep range 0 to ±30 db Relative to the original power level and limited by the source to be controlled Measurement time (default RBW setting of the PSA Series determined by Option 215) ESG or PSG MXG 101 Sweep points 2.9 s (nominal) 1.1 s (nominal) 601 Sweep points 9.5 s (nominal) 1.9 s (nominal) Supported external sources Agilent PSG signal generators Agilent ESG signal generators Agilent MXG signal generators Models: E8257D, E8267D (firmware version C or later). E8247C, E8257C, E8267C (firmware version C or later). Model: E4438C (firmware version C or later), E4428C (firmware version C or later). Models: N5181A, N5182A, N5183A (firmware version A or later). 14
15 PSA Series Ordering Information For further information, refer to PSA Series Configuration Guide, EN PSA Series spectrum analyzer E4443A 3 Hz to 6.7 GHz E4445A 3 Hz to 13.2 GHz E4440A 3 Hz to 26.5 GHz E4447A 3 Hz to GHz E4446A 3 Hz to 44 GHz E4448A 3 Hz to 50 GHz Options To add options to a product, use the following ordering scheme: Model E444xA (x = 0, 3, 5, 6, 7 or 8) Example options E4440A-B7J, E4448A-1DS Warranty & Service Standard warranty is three years. R-51B-001-5C Warranty Assurance Plan, Return to Agilent, 5 years Calibration 1 R-50C R-50C Calibration Assurance Plan, Return to Agilent, 3 years Calibration Assurance Plan, Return to Agilent, 5 years R-50C Agilent Calibration + Uncertainties + Guardbanding, 3 years R-50C Agilent Calibration + Uncertainties + Guardbanding, 5 years AMG A6J R-50C R-50C UK6 E444xA-0BW R-52A N7810A Agilent Calibration + Uncertainties + Guardbanding (accredited cal) ANSI Z Calibration ANSI Z Calibration, 3 years ANSI Z Calibration, 5 years Commercial calibration certificate with data To be ordered with PSA Service manual Calibration software and licensing (ordered with PSA) PSA Series calibration application software (stand-alone order) 1. Options not available in all countries Measurement Personalities E444xA-226 Phase noise E444xA-219 Noise figure Requires Option IDS or 110 to meet specifications E444xA-241 Flexible digital modulation analysis E444xA-BAF W-CDMA Requires B7J E444xA-210 HSDPA/HSUPA (for W-CDMA) Requires B7J and BAF E444xA-202 GSM w/ EDGE Requires B7J E444xA-B78 cdma2000 Requires B7J E444xA-214 1xEV-DV Requires B7J and B78 E444xA-204 1xEV-DO Requires B7J E444xA-BAC cdmaone Requires B7J E444xA-BAE NADC, PCD Requires B7J E444xA-217 WLAN Requires 122 or 140 E444xA-211 TD-SCDMA power measurement E444xA-212 TD-SCDMA modulation E444xA-213 HSPA for TD-SCDMA Requires Option 212 E444xA-215 External source control E444xA-266 Programming code compatibility suite E444xA-233 Built-in measuring receiver personality E444xA-23A AM/FM/PM triggering Requires Option 233 E444xA-23B CCITT filter Requires Options 233 E444xA-239 N9039A RF preselector control Hardware E444xA-1DS RF internal preamplifier (100 khz to 3 GHz) Excludes 110 E444xA-110 RF/µW internal preamplifier (10 MHz Excludes 1DS to upper frequency limit of the PSA) E444xA-B7J Digital demodulation hardware E444xA MHz bandwidth digitizer E4440A/43A/45A/46A/48A, excludes 140, 107, H70 E444xA MHz bandwidth digitizer E4440A/43A/45A/46A/48A, excludes 122, 107, H70 E444xA-123 Switchable MW preselector bypass Excludes AYZ E444xA-124 Y-axis video output E444xA-AYZ External mixing E4440A/47A/46A/48A only, excludes 123 E444xA-107 Audio input 100 kω Requires 233 to operate; excludes 122, 140 E444xA-111 USB device side I/O interface Now shipped standard E444xA MB user memory Excludes 117, Shipped standard in all PSA instruments with serial number prefix MY4615 unless 117 is installed E4440A-BAB Replaces type-n input connector with APC 3.5 connector E444xA-H70 70 MHz IF output Excludes 122, 140. Not available for E4447A E444xA-HYX 21.4 MHz IF output Available for all PSA models PC Software E444xA-230 BenchLink Web Remote Control Software E444xA-235 Wide BW digitizer external Requires 122 or 140 calibration wizard E4443A/45A/40A/46A/48A Accessories E444xA-1CM E444xA-1CN E444xA-1CP E444xA-1CR E444xA-015 E444xA-045 E444xA-0B1 Rack mount kit Front handle kit Rack mount with handles Rack slide kit 6 GHz return loss measurement accessory kit Millimeter wave accessory kit Extra manual set including CD ROM 15
16 Product Literature Publication Title Publication Type Publication Number PSA Series Selecting the Right Signal Analyzer for Your Needs Selection Guide E PSA Series Brochure E PSA Series Data Sheet E PSA Series Configuration Guide EN Self-Guided Demonstration for Spectrum Analysis Product Note EN Wide bandwidth and vector signal analysis 40/80 MHz Bandwidth Digitizer Technical Overview EN Using Extended Calibration Software for Wide Bandwidth Measurements, Application Note EN PSA Option 122 & VSA PSA Series Spectrum Analyzer Performance Guide Using 89601A Vector Signal Product Note EN Analysis Software 89650S Wideband VSA System with High Performance Spectrum Analysis Technical Overview EN Measurement personalities and applications Phase Noise Measurement Personality Technical Overview EN Noise Figure Measurement Personality Technical Overview EN External Source Measurement Personality Technical Overview EN Flexible Modulation Analysis Measurement Personality Technical Overview EN W-CDMA and HSDPA/HSUPA Measurement Personalities Technical Overview EN GSM with EDGE Measurement Personality Technical Overview EN cdma2000 and 1xEV-DV Measurement Personalities Technical Overview EN 1xEV-DO Measurement Personality Technical Overview EN cdmaone Measurement Personality Technical Overview EN WLAN Measurement Personality Technical Overview EN NADC/PDC Measurement Personality Technical Overview EN TD-SCDMA Measurement Personality Technical Overview EN Built-in Measuring Receiver Personality / Agilent N5531S Measuring Receiver Technical Overview EN BenchLink Web Remote Control Software Product Overview EN IntuiLink Software Data Sheet EN Programming Code Compatibility Suite Technical Overview EN EMI Measurement Receiver Product Overview EN Hardware options PSA Series Spectrum Analyzers Video Output (Option 124) Technical Overview EN PSA Series Spectrum Analyzers, Option H70,70 MHz IF Output Product Overview EN Spectrum analyzer fundamentals Optimizing Dynamic Range for Distortion Measurements Product Note EN PSA Series Amplitude Accuracy Product Note EN PSA Series Swept and FFT Analysis Product Note EN PSA Series Measurement Innovations and Benefits Product Note EN Spectrum Analysis Basics Application Note Vector Signal Analysis Basics Application Note EN 8 Hints for Millimeter Wave Spectrum Measurements Application Note EN Spectrum Analyzer Measurements to 325 GHz with the Use of External Mixers Application Note EN EMI Application Note E 16
17 myagilent A personalized view into the information most relevant to you. LAN extensions for Instruments puts the power of Ethernet and the Web inside your test systems. Agilent is a founding member of the LXI consortium. Three-Year Warranty Beyond product specification, changing the ownership experience. Agilent is the only test and measurement company that offers three-year warranty on all instruments, worldwide Agilent Assurance Plans Five years of protection and no budgetary surprises to ensure your instruments are operating to specifications and you can continually rely on accurate measurements. Agilent Electronic Measurement Group DEKRA Certified ISO 9001:2008 Quality Management System Agilent Channel Partners Get the best of both worlds: Agilent s measurement expertise and product breadth, combined with channel partner convenience. For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: Americas Canada (877) Brazil (11) Mexico United States (800) Asia Pacific Australia China Hong Kong India Japan 0120 (421) 345 Korea Malaysia Singapore Taiwan Other AP Countries (65) Europe & Middle East Belgium 32 (0) Denmark Finland 358 (0) France * *0.125 /minute Germany 49 (0) Ireland Israel /544 Italy Netherlands 31 (0) Spain 34 (91) Sweden United Kingdom 44 (0) For other unlisted countries: (BP ) Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc Published in USA, November 25, EN
Agilent E5063A ENA Series Network Analyzer
Agilent E5063A ENA Series Network Analyzer 100 khz to 4.5/ 8.5/18 GHz Configuration Guide Ordering Guide The following steps will guide you through configuring your E5063A. Standard furnished item Description
Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide
Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors Demo Guide Introduction This demonstration guide helps you to get familiar with the basic setup and coniguration requirements
What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope?
What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope? Application Note In the past, deciding between an equivalent time sampling oscilloscope and a real
Agilent E5063A ENA Series Network Analyzer. 100 khz to 4.5/ 8.5/18 GHz
Agilent E5063A ENA Series Network Analyzer 100 khz to 4.5/ 8.5/18 GHz The Best Balance Between Price and Performance The E5063A is a low cost network analyzer for simple passive component testing up to
U7248A High Speed Inter-Chip (HSIC) Electrical Test Software Infiniium Oscilloscopes
U7248A High Speed Inter-Chip (HSIC) Electrical Test Software Infiniium Oscilloscopes Data Sheet This application is available in the following license variations Order N7248A for user-installed license
X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software
X-Series Signal Analysis Future-ready instruments Consistent measurement framework Broadest set of applications and software Arrive Ahead with X-Series We can t predict the future, but Agilent can help
Agilent E363xA Series Programmable DC Power Supplies. Data Sheet
Agilent E363xA Series Programmable DC Power Supplies Data Sheet Reliable Power, Repeatable Results Single and triple output 80 W to 200 W output power Dual range output Low noise and excellent regulation
Agilent Compatibility of the U2000 Series USB Power Sensors with Agilent Instruments. Application Note
Agilent Compatibility of the U2000 Series USB Power Sensors with Agilent Instruments Application Note Table of Contents Introduction 2 U2000 Series USB Power 3 Sensor s Compatibility with Agilent Instruments
Evaluating Oscilloscope Bandwidths for Your Application
Evaluating Oscilloscope Bandwidths for Your Application Application Note Table of Contents Introduction....1 Defining Oscilloscope Bandwidth.....2 Required Bandwidth for Digital Applications...4 Digital
Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy
Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy Application Note RF & Microwave Spectrum Analyzers Table of Contents 3 3 4 4 5 7 8 8 13 13 14 16 16 Introduction Absolute versus relative
How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer
How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer Application Note Introduction In a pulsed radar system, one of the key transmitter-side components
Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet
Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet Use BenchVue software to: Visualize multiple measurements simultaneously Easily capture data, screen shots and
Agilent U2000 Series USB Power Sensors
Agilent U2000 Series USB Power Sensors Configuration Guide U2000 Series USB Power Sensors U2000A (10 MHz to 18 GHz) U2001A (10 MHz to 6 GHz) U2002A (50 MHz to 24 GHz) U2004A (9 khz to 6 GHz) U2000H (10
Agilent Compatibility of USB Power Sensors with Agilent Instruments. Application Note
Agilent Compatibility of USB Power Sensors with Agilent Instruments Application Note Use USB Power Sensors as an Agilent Instruments Accessory Table of Contents Agilent USB Power Sensors 2 USB Power Sensor
Agilent FieldFox Remote Viewer
Agilent FieldFox Remote Viewer Application Brief Agilent Remote Viewer setup instructions The FieldFox remove viewer is a FREE ios application which allows you to view an Agilent FieldFox analyzer from
Keysight M9485A PXIe Multiport Vector Network Analyzer. Configuration Guide
Keysight M9485A PXIe Multiport Vector Network Analyzer Configuration Guide 02 Keysight M9485A PXIe Multiport Vector Network Analyzer - Configuration Guide Ordering Guide The following steps will guide
Agilent U2000 Series USB Power Sensors
Agilent U2000 Series USB Power Sensors GSM Timeslot Burst Power Measurement Product Note Table of Content Introduction 2 Measuring GSM Timeslot 4 Signal Overview of Agilent U2000 5 Series USB Power Sensors
802.11ac Power Measurement and Timing Analysis
802.11ac Power Measurement and Timing Analysis Using the 8990B Peak Power Analyzer Application Note Introduction There are a number of challenges to anticipate when testing WLAN 802.11ac [1] power amplifier
Basics of RF Amplifier Measurements with the E5072A ENA Series Network Analyzer
Basics of RF Amplifier Measurements with the E5072A ENA Series Network Analyzer Application Note Introduction The RF power amplifier is a key component used in a wide variety of industries such as wireless
Impedance 50 (75 connectors via adapters)
VECTOR NETWORK ANALYZER PLANAR TR1300/1 DATA SHEET Frequency range: 300 khz to 1.3 GHz Measured parameters: S11, S21 Dynamic range of transmission measurement magnitude: 130 db Measurement time per point:
Keysight Technologies 8 Hints for Better Spectrum Analysis. Application Note
Keysight Technologies 8 Hints for Better Spectrum Analysis Application Note The Spectrum Analyzer The spectrum analyzer, like an oscilloscope, is a basic tool used for observing signals. Where the oscilloscope
Agilent E5061B Network Analyzer. 100 khz to 1.5 GHz/3 GHz 5 Hz to 3 GHz
Agilent E5061B Network Analyzer 100 khz to 1.5 GHz/3 GHz 5 Hz to 3 GHz E5061B responds to various measurement needs, from LF to RF The Agilent E5061B is a member of the industry standard ENA Series network
Agilent PN 8753-1 RF Component Measurements: Amplifier Measurements Using the Agilent 8753 Network Analyzer. Product Note
Agilent PN 8753-1 RF Component Measurements: Amplifier Measurements Using the Agilent 8753 Network Analyzer Product Note 2 3 4 4 4 4 6 7 8 8 10 10 11 12 12 12 13 15 15 Introduction Table of contents Introduction
Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics
Jeff Thomas Tom Holmes Terri Hightower Learn RF Spectrum Analysis Basics Learning Objectives Name the major measurement strengths of a swept-tuned spectrum analyzer Explain the importance of frequency
Make Better RMS Measurements with Your DMM
Make Better RMS Measurements with Your DMM Application Note Introduction If you use a digital multimeter (DMM) for AC voltage measurements, it is important to know if your meter is giving you peak value,
Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network
Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network Application Brief Test Challenges: Designing heating and air conditioning (HVAC) systems Collecting data on a remotely located
N6171A MATLAB Data Analysis Software for Agilent Instruments
N6171A MATLAB Data Analysis Software for Agilent Instruments Technical Overview MATLAB is available directly from Agilent or its authorized sales partners with your instrument purchase Use MATLAB to create
Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz
Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz The Giga-tronics Model 8003 Precision Scalar Network Analyzer combines a 90 db wide dynamic range with the accuracy and linearity
Real-Time Spectrum Analysis for Troubleshooting 802.11n/ac WLAN Devices
Real-Time Spectrum Analysis for Troubleshooting 802.11n/ac WLAN Devices Application Brief 802.11 WLAN devices operate in the license-exempt 2.4 GHz ISM and 5 GHz UNII bands, where they must share spectrum
Keysight N9320B RF Spectrum Analyzer
Keysight N9320B RF Spectrum Analyzer 9 khz to 3.0 GHz Data Sheet 02 Keysight N9320B RF Spectrum Analyzer - Data Sheet Definitions and Conditions Specifications describe the performance of parameters covered
Performing Amplifier Measurements with the Vector Network Analyzer ZVB
Product: Vector Network Analyzer R&S ZVB Performing Amplifier Measurements with the Vector Network Analyzer ZVB Application Note This document describes typical measurements that are required to be made
Keysight Technologies N9320B RF Spectrum Analyzer
Keysight Technologies N9320B RF Spectrum Analyzer 9 khz to 3.0 GHz Data Sheet Definitions and Conditions The spectrum analyzer will meet its specifications when: It is within its calibration cycle It has
Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics
Jeff Thomas Tom Holmes Terri Hightower Learn RF Spectrum Analysis Basics Agenda Overview: Spectrum analysis and its measurements Theory of Operation: Spectrum analyzer hardware Frequency Specifications
Agilent MATLAB Data Analysis Software Packages for Agilent Oscilloscopes
Agilent MATLAB Data Analysis Software Packages for Agilent Oscilloscopes Data Sheet Enhance your InfiniiVision or Infiniium oscilloscope with the analysis power of MATLAB software Develop custom analysis
The Next Generation in Automated Oscilloscope Test
The Next Generation in Automated Oscilloscope Test Spanning 100 MHz to 13 GHz, and varying in height from 1U to 8U, Agilent s family of LXI compliant oscilloscopes can accommodate virtually any automated
Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet
Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers Data Sheet Specifications Specifications are only valid for the stated operating frequency, and apply over 0 C to +55 C unless otherwise
Agilent AN 1315 Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note
Agilent AN 1315 Optimizing RF and Microwave Spectrum Analyzer Dynamic Range Application Note Table of Contents 3 3 3 4 4 4 5 6 7 7 7 7 9 10 10 11 11 12 12 13 13 14 15 1. Introduction What is dynamic range?
Keysight N6854A Geolocation System. Configuration Guide
Keysight N6854A Geolocation System Configuration Guide 02 Keysight N6854A Geolocation System - Configuration Guide This guide will help you configure a geolocation system that meets your needs and includes
Agilent Test Solutions for Multiport and Balanced Devices
Agilent Test Solutions for Multiport and Balanced Devices Duplexer test solutions 8753ES option H39/006 During design and final alignment of duplexers, it is often necessary to see both the transmit-antenna
DDR Memory Overview, Development Cycle, and Challenges
DDR Memory Overview, Development Cycle, and Challenges Tutorial DDR Overview Memory is everywhere not just in servers, workstations and desktops, but also embedded in consumer electronics, automobiles
Keysight Technologies Understanding and Improving Network Analyzer Dynamic Range. Application Note
Keysight Technologies Understanding and Improving Network Analyzer Dynamic Range Application Note Introduction Achieving the highest possible network analyzer dynamic range is extremely important when
Agilent U2000 Series USB Power Sensors
Agilent U2000 Series USB Power Sensors Single/Multi-Channel Power Measurement Simple Setup Affordable Demo Guide Table of Contents Introduction 2 The Agilent N1918A Power 3 Analysis Manager Demonstration
Testing WiMAX receiver performance in a multipath propagation environment using Agilent s E6651A with an EB Propsim C8 radio channel emulator
Testing WiMAX receiver performance in a multipath propagation environment using Agilent s E6651A with an EB Propsim C8 radio channel emulator Application Note 1 Summary Introduction As a part of the certification
Scalar Network Analysis with the HP 8590 Series Spectrum Analyzers Product Overview
This literature was published years prior to the establishment of Agilent Technologies as a company independent from Hewlett-Packard and describes products or services now available through Agilent. It
Agilent E5100A Network Analyzer
Agilent E5100A Network Analyzer Data Sheet These specifications are the performance standards or limits against which the instrument is tested. When shipped from the factory, the E5100A meets the specifications
R&S FSW signal and spectrum analyzer: best in class now up to 50 GHz
R&S FSW signal and spectrum analyzer: best in class now up to 50 GHz The new R&S FSW 43 and R&S FSW 50 signal and spectrum analyzers make the outstanding features of the R&S FSW family available now also
Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview
Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview Reduce your cost of ownership by minimizing time to calibrate and
Agilent E6832A W-CDMA Calibration Application
Agilent E6832A W-CDMA Calibration Application For the E6601A Wireless Communications Test Set Data Sheet The next generation of mobile phone manufacturing test. E6601A is the newest test set from Agilent
Time-Correlated Multi-domain RF Analysis with the MSO70000 Series Oscilloscope and SignalVu Software
Time-Correlated Multi-domain RF Analysis with the MSO70000 Series Oscilloscope and SignalVu Software Technical Brief Introduction The MSO70000 Series Mixed Oscilloscope, when coupled with SignalVu Spectrum
N5416A and N5417A USB Compliance Test Software for Infiniium Oscilloscopes
N546A and N547A USB Compliance Test Software for Infiniium Oscilloscopes Data Sheet The N546A USB compliance test software for Infiniium oscilloscopes gives you a fast and reliable way to verify USB electrical
Agilent Electronic Calibration (ECal) Modules for Vector Network Analyzers
Agilent Electronic Calibration (ECal) Modules for Vector Network Analyzers N4690 Series, 2-port Microwave ECal 85090 Series, 2-port RF ECal N4430 Series, 4-port ECal Technical Overview Control ECal directly
Keysight Technologies Long-Term, Remote Monitoring of Satellite Performance
Keysight Technologies Long-Term, Remote Monitoring of Satellite Performance Using a Keysight High-Frequency USB Power Sensor Application Note 1.0 Introduction Satellite communication systems are driven
E5092A Configurable Multiport Test Set
Keysight Technologies E5080A Network Analyzer 9 khz to 4.5/6.5/9 GHz E5092A Configurable Multiport Test Set Configuration Guide 02 Keysight 5080A Network Analyzer & E5092A Configurable Multiport Test Set
Agilent 8753ET/8753ES Network Analyzers
Agilent 8753ET/8753ES Network Analyzers 8753ET, 300 khz to 3 or 6 GHz 8753ES, 30 khz to 3 or 6 GHz Configuration Guide System configuration summary The following summary lists the main components required
Agilent 4339B/4349B High Resistance Meters
Agilent 4339B/4349B High Resistance Meters Technical Overview Within Budget Without Compromise Introducing the Agilent Technologies 4339B and 4349B High Resistance Meters Used for Making Ultra- High Resistance
Agilent 87421A/87422A Power Supply
Agilent 87421A/87422A Power Supply Technical Overview Designed specifically for Agilent Technologies microwave system amplifiers Bias cable permits remote placement Compact size for easy system integration
MATRIX TECHNICAL NOTES
200 WOOD AVENUE, MIDDLESEX, NJ 08846 PHONE (732) 469-9510 FAX (732) 469-0418 MATRIX TECHNICAL NOTES MTN-107 TEST SETUP FOR THE MEASUREMENT OF X-MOD, CTB, AND CSO USING A MEAN SQUARE CIRCUIT AS A DETECTOR
Agilent N5970A Interactive Functional Test Software: Installation and Getting Started
Agilent N5970A Interactive Functional Test Software: Installation and Getting Started Application Note The N5970A Interactive Functional Test Software along with the 8960 Series 10 (E5515C) wireless communications
Optimizing IP3 and ACPR Measurements
Optimizing IP3 and ACPR Measurements Table of Contents 1. Overview... 2 2. Theory of Intermodulation Distortion... 2 3. Optimizing IP3 Measurements... 4 4. Theory of Adjacent Channel Power Ratio... 9 5.
Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet
Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price Data Sheet Features 120000 counts resolution 16 built-in measurement functions including temperature and
Keysight N9000A CXA Signal Analyzer
Keysight N9000A CXA Signal Analyzer Notice: This document contains references to Agilent. Please note that Agilent s Test and Measurement business has become Keysight Technologies. For more information,
Agilent 8720 Family Microwave Vector Network Analyzers
Agilent 8720 Family Microwave Vector Network Analyzers Product Overview High-Performance Solutions for Your Measurement Challenges Now more choices for solving your measurement challenges What's new in
Measurement Guide and Programming Examples
Measurement Guide and Programming Examples PSA and ESA Series Spectrum Analyzers This manual provides documentation for the following instruments: Agilent Technologies PSA Series E4443A (3 Hz - 6.7 GHz)
DSA800 Series Spectrum Analyzer
DSA800 Series Spectrum Analyzer Configuration Guide This guide is used to help users to configure DSA800 series spectrum analyzer according to their requirements. You can get an overall understanding of
Experiment 7: Familiarization with the Network Analyzer
Experiment 7: Familiarization with the Network Analyzer Measurements to characterize networks at high frequencies (RF and microwave frequencies) are usually done in terms of scattering parameters (S parameters).
Power Amplifier Gain Compression Measurements
Technical Brief Power Amplifier Gain Compression Measurements GPIB Private Bus Sweep Out Sweep In Pulse In AC Mod Out Blank/Marker Out Blanking In Overview The 1 db gain compression of an amplifier describes
Agilent 8762/3/4A,B,C Coaxial Switches
Agilent 8762/3/4A,B,C Coaxial Switches Technical Overview High performance switches for microwave and RF instrumentation and systems Agilent Technologies offers a ver satile line of multiport coaxial switches.
TekConnect Adapters. TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM Data Sheet. Applications. Features & Benefits
TekConnect Adapters TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM Data Sheet TCA-N TekConnect-to-N DC to 11 GHz (Instrument Dependent) 50 Ω Input (Only) TCA-SMA TekConnect-to-SMA DC to 18 GHz (Instrument Dependent)
Keysight Technologies Using Fine Resolution to Improve Thermal Images. Application Note
Keysight Technologies Using Fine Resolution to Improve Thermal Images Application Note Introduction Digital imaging opened up new possibilities and has been very much part of our lives since social media
Network Analyzer Operation
Network Analyzer Operation 2004 ITTC Summer Lecture Series John Paden Purposes of a Network Analyzer Network analyzers are not about computer networks! Purposes of a Network Analyzer Measures S-parameters
EE 186 LAB 2 FALL 2004. Network Analyzer Fundamentals and Two Tone Linearity
Network Analyzer Fundamentals and Two Tone Linearity Name: Name: Name: Objective: To become familiar with the basic operation of a network analyzer To use the network analyzer to characterize the in-band
Making Spectrum Measurements with Rohde & Schwarz Network Analyzers
Making Spectrum Measurements with Rohde & Schwarz Network Analyzers Application Note Products: R&S ZVA R&S ZVB R&S ZVT R&S ZNB This application note describes how to configure a Rohde & Schwarz Network
A Guide to Calibrating Your Spectrum Analyzer
A Guide to Calibrating Your Application Note Introduction As a technician or engineer who works with electronics, you rely on your spectrum analyzer to verify that the devices you design, manufacture,
Keysight E5063A ENA Series PCB Analyzer
Keysight E5063A ENA Series PCB Analyzer Technical Overview The Best Solution for PCB Manufacturing Test More accuracy and R&R More languages supported More ESD robustness Why choose the E5063A PCB Analyzer
R&S ZNC Vector Network Analyzer Specifications
ZNC3_dat-sw_en_5214-5610-22_v0300_cover.indd 1 Data Sheet 03.00 Test & Measurement R&S ZNC Vector Network Analyzer Specifications 04.09.2012 13:39:47 CONTENTS Definitions... 3 Measurement range... 4 Measurement
Agilent 4338B Milliohm Meter
Agilent 4338B Milliohm Meter 10 µω to 100 kω Technical Overview Introduction Ideal for precise measurements of extremely low resistances using an ac test signal, the Agilent Technologies 4338B suits bench-top
Calibration Guide. Agilent Technologies ESG Vector Signal Generator
Calibration Guide Agilent Technologies ESG Vector Signal Generator This guide applies to signal generator models and associated serial number prefixes listed below. Depending on your firmware revision,
Agilent Mobile WiMAX R&D Test Set Solutions: Software and Technical Support Contract
Agilent Mobile WiMAX R&D Test Set Solutions: Software and Technical Support Contract Product Overview Maximize the potential of the E6651A Mobile WiMAX test set and related software with the latest software
RF Network Analyzer Basics
RF Network Analyzer Basics A tutorial, information and overview about the basics of the RF Network Analyzer. What is a Network Analyzer and how to use them, to include the Scalar Network Analyzer (SNA),
Agilent 8757D Scalar Network Analyzer 10 MHz to 110 GHz
Agilent 8757D Scalar Network Analyzer 10 MHz to 110 GHz Data Sheet Accurate measurement of transmission and reflection characteristics is a key requirement in your selection of a scalar network analyzer.
ECE 435 INTRODUCTION TO THE MICROWAVE NETWORK ANALYZER
ECE 435 INTRODUCTION TO THE MICROWAVE NETWORK ANALYZER Latest revision: October 1999 Introduction A vector network analyzer (VNA) is a device capable of measuring both the magnitude and phase of a sinusoidal
2398 9 khz to 2.7 GHz Spectrum Analyzer
Spectrum Analyzers 2398 9 khz to 2.7 GHz Spectrum Analyzer A breakthrough in high performance spectrum analysis, combining cost effectiveness and portability in a new lightweight instrument 9 khz to 2.7
Fast and Accurate Test of Mobile Phone Boards
Products: R&S FSP Fast and Accurate Test of Mobile Phone Boards Short test times in conjunction with accurate and repeatable measurement results are essential when testing and calibrating mobile phones
E5061B-3L5 LF-RF Network Analyzer with Option 005 Impedance Analysis Function. Data Sheet
E506B-3L5 LF-RF Network Analyzer with Option 005 Impedance Analysis Function Data Sheet E506B-3L5 with Option 005; NA plus ZA in one box To ensure the performance and reliability of electronic equipment,
Agilent 8510-13 Measuring Noninsertable Devices
Agilent 8510-13 Measuring Noninsertable Devices Product Note A new technique for measuring components using the 8510C Network Analyzer Introduction The majority of devices used in real-world microwave
MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER
MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER W. Li, J. Vandewege Department of Information Technology (INTEC) University of Gent, St.Pietersnieuwstaat 41, B-9000, Gent, Belgium Abstract: Precision
Using Spectrum Analyzers For Signal Monitoring
Using Spectrum Analyzers For Signal Monitoring Presented by: 3 March 004 1 1 At the completion of this module you will have an understanding of how commercially available spectrum analyzers can be used
Agilent Infoline Web Services. Quick Reference Guide. Scan and use your phone to go to Infoline at www.agilent.com/find/service
Agilent Infoline Web Services Quick Reference Guide Scan and use your phone to go to Infoline at www.agilent.com/find/service One location for all information This quick reference guide reviews the powerful
An Overview of the Electrical Validation of 10BASE-T, 100BASE-TX, and 1000BASE-T Devices
An Overview of the Electrical Validation of 10BASE-T, 100BASE-TX, and 1000BASE-T Devices Application Note The number of devices that come with a built-in network interface card has risen steadily and will
Network analyzer and spectrum analyzer two in one
R&S ZVL Vector Network Analyzer Network analyzer and spectrum analyzer two in one The R&S ZVL is the lightest and smallest vector network analyzer in its class. On top of this, it can be used as a full-featured
The demo guide contains
The demo guide contains 1. Demo configuration, units are available in the Agilent demstock 2. Remote Demo, a remote setup is available in Böblingen. Booking is possible via a demo outlook calendar. Please
Agilent E4401B, E4402B, E4404B, E4405B, and E4407B ESA-E Series Spectrum Analyzers
Agilent, E4402B, E4404B, E4405B, and E4407B ESA-E Series Spectrum Analyzers Technical Specifications All specifications apply over 0 C to + 55 C unless otherwise noted. The analyzer will meet its specifications
Variable Frequency Drive Troubleshooting with U1610A/U1620A
Variable Frequency Drive Troubleshooting with U1610A/U1620A Application Note Electric motors form the backbone of most industrial and manufacturing environments. Variable frequency drives (VFDs) (also
Errata. Agilent Technologies PSA Series Spectrum Analyzers
Errata Agilent Technologies PSA Series Spectrum Analyzers This document contains supplemental information for instruments with firmware A.11.21 The latest revision of the firmware can be found at http://www.agilent.com/find/psa_firmware
Conquering Noise for Accurate RF and Microwave Signal Measurements. Presented by: Ernie Jackson
Conquering Noise for Accurate RF and Microwave Signal Measurements Presented by: Ernie Jackson The Noise Presentation Review of Basics, Some Advanced & Newer Approaches Noise in Signal Measurements-Summary
High Power Amplifier Measurements Using Agilent s Nonlinear Vector Network Analyzer
High Power Amplifier Measurements Using Agilent s Nonlinear Vector Network Analyzer Application Note 1408-19 Table of Contents Introduction...2 PNA-X Performance...3 Hardware Setup...6 Setup Examples...12
Agilent P940xA/C Solid State PIN Diode Switches
Agilent P940xA/C Solid State PIN Diode Switches Operating and Service Manual Agilent Technologies Notices Agilent Technologies, Inc. 2007 No part of this manual may be reproduced in any form or by any
Measuring ACLR Performance in LTE Transmitters. Application Note
Measuring ACLR Performance in LTE Transmitters Application Note Introduction As wireless service providers push for more bandwidth to deliver IP services to more users, LTE has emerged as a next-generation
Spectrum and Power Measurements Using the E6474A Wireless Network Optimization Platform
Application Note Spectrum and Power Measurements Using the E6474A Wireless Network Optimization Platform By: Richard Komar Introduction With the rapid development of wireless technologies, it has become