Nationally Described Space Standard technical requirements. Consultation draft. September 2014



Similar documents
Technical housing standards nationally described space standard

Technical housing standards nationally described space standard

HOUSING STANDARDS POLICY TRANSITION STATEMENT IMPLEMENTATION: OCTOBER May 2015

Housing standards: evidence and research. Dwelling size survey. A report prepared by Scott Wilson for CABE in April 2010.

Building Control Guidance Note

What you need to know about. Smoke alarms for residential buildings

Approved Document M: Part M Access to and use of buildings Volume 1 dwellings. Consultation draft. August 2014

Northern Ireland Housing Executive: HMO Fire Safety Guide

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010

EAST LONDON HMO GUIDANCE (4)

Guide to Houses in Multiple Occupation Self Contained Flats

APPLICATION NO. 15/P/00168 RECEIVED: 27-Mar Change of use of shop to residential flat (first floor) and shop alterations

Access to and use of buildings

BUILDING CONTROL GUIDANCE SHEET SMOKE ALARMS IN STANDARD DWELLINGS Last updated 16/12/2010

EAST LONDON GUIDANCE ON HMO STANDARDS (3)

What are we discussing with you today?

25 PARSON STREET WILNECOTE TAMWORTH B77 5BD

Rochdale Building Control Guide. Approved Document F Means of ventilation

Residential SALES. 71 Oxhey Lane, Hatch End, Pinner, Greater London, HA5 4AY. pulvercarr.co pulvercarr.co.

ENVIRONMENTAL HEALTH PROFESSIONAL PRACTICE VOL II CHAPTER III. HOUSES IN MULTIPLE OCCUPATION Space Standards

Guidance on loft conversions in two-storey houses

City of Peterborough

Fire precautions in dwellings. Private sector housing Providing homes building communities

LONDON BOROUGH OF BROMLEY STANDARDS FOR HOUSES IN MULTIPLE OCCUPATION (HMO) INTRODUCTION

SOUTH GLOUCESTERSHIRE COUNCIL SPECIFICATION REQUIREMENTS FOR WHEELCHAIR UNITS - DRAFT

BUILDING PERMIT SPECIFICATIONS

8 Birkdale Avenue. Branston, Burton upon Trent, DE14 3HN. Choice Plot

HOUSES IN MULTIPLE OCCUPATION STANDARDS. Housing Executive

Ministry of the Environment Decree. on housing design

Building Control. Householder Guidance Leaflet No. 29. Fire detection in dwellings

Practice Note

Holiday Cottage / Live Work Home

720r Addendum: Siting the 720r

Energy Company Obligation (ECO): Technical Monitoring Questions

Issue ID Description No. of Credits Available. Mandatory Elements Storage of Non-recyclable Waste and Recyclable Household Waste

FIRE DETECTION AND ALARM SYSTEMS

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

Fire. The Fire Installers Mate. A guide to fire alarm systems design

June 7, 2010 Page 1 of 5

Wheelchair homes design guidelines. Guidelines to achieve the necessary standards for wheelchair users dwellings

SCHEDULE OF FINISHES AMBLE RIDGE RETIREMENT VILLAGE

FREEHOLD INVESTMENT/DEVELOPMENT OPPORTUNITY SWAN YARD HIGHBURY CORNER, LONDON, N1

Applies to: All Employees within the Facilities Management Department (FMD)

Schedule B to By-law Part A Fees Payable for Permits

New York, Dean. Price 182,500

Waste and Recycling Storage and Collection Guidance for Houses, Flats, Houses of Multiple Occupancy, New Builds, and Conversions.

Design and Access Statement Earls Court Road London SW5 9RH

Measuring Houses and Counting Rooms. Using the ANSI Standards

LARGE DINING ROOM A MOST ATTRACTIVE 3 BEDROOMED DETACHED HOUSE, HAVING BEEN

Smoke Alarms. New smoke alarm requirements for existing buildings from 1 May Introduction. Advisory note March 2006

Contents. 1. Introduction 1.1 Reason for this Guide Interpretation 1.3 Principles of Fire Safety 1.4 Legal Provisions 4

Fire Alarm system Installation Guide

wrightmarshall.co.uk fineandcountry.com MANCHESTER ROAD MARTON SK11 9HN GUIDE PRICE 750,000

Refuse and recycling storage guidance

London Borough of Barnet. Fire Safety in Houses in Multiple Occupation. A Guide to Landlords

ARGYLE ROAD WEST EALING W13

Code of Measuring Practice

H:\forms\handouts\bldg049 1 of 11 Revised Mar 2/15/dh

31 Linden Lane Kirby Muxloe Leicestershire LE9 2EG

HA5 4JX T: NEW Instruction. One Bedroom Retirement Flat for the over 60's. Greater London HA5 4JX. 523 Uxbridge Road Road

Design Development Quality Management Phase Checklist Project Phase Checklist Series

Protection from falling. collision and impact. The Building Regulations edition for use in England* ONLINE VERSION APPROVED DOCUMENT

Blackhorse Lane Croydon Surrey CR0 375,000

GENERAL + MEANS OF ESCAPE (Part One) By Mdm Eng Yew Hoon (SIA)

11 RATTRAY PLACE, ABERDEEN, AB24 2TJ

The Art Institute of Houston Summer 2010 Instructor : Rhonda Jones. 1. Concept Statement 7. One Line Diagram. 2. Program 8. Preliminary Floor Plan

Gas Water Heaters Regulation 35A of Building (Planning) Regulations

Hole In One. Freehold 425,000 + VAT SOLE SELLING RIGHTS REF: NW Forest Drive, Lytham, St Annes, Lancashire FY8 4QF

17,280 square feet Overview:

Schedule B to By-law

London Housing Design Guide INTERIM EDITION

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Fire Alarm Systems Design. a guide to BS5839

Planning Technical Advice Note: Waste bin storage and access requirements for new and change of use developments

Valuation Report. Property Address: Bristol. Date Inspected: 14 August 2013 CHARTERED SURVEYORS AUCTIONEERS VALUERS ESTATE AGENTS

POSEIDON COURT ISLE OF DOGS E14

HARFIELD GARDENS GROVE LANE LONDON SE5 385,000 FREEHOLD

Moonacres Beaulieu, Hampshire

Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS

Minimum Housing and Health Standards

- 5 - Table1. Maximum Compartment Volumes

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

ONLINE VERSION. The Building Regulations 2010 The Building (Approved Inspectors etc) Regulations 2010 ONLINE VERSION

DOMESTIC SMOKE ALARMS

81-91 COMMERCIAL ROAD, LONDON E1 1RD OFFICES TO LET COMMERCIAL ROAD, LONDON E1 1RD. 3,499 ft² (325 m²) 37,222 ft² (3,458 m²)

46 Sylvan Avenue BITTERNE, SOUTHAMPTON, SO19 5JU

PYMOOR 105,000. cheffins.co.uk

Exempted Development - Frequently Asked Questions

Waste & Recycling. Planning Guidance on Waste & Recycling Storage and Collection. Development & Enterprise FOR INTERNAL USE ONLY.

The White House 15 Whirlow Park Road, Sheffield. Park Estates

JSP 315 SCALE 45 1 OFFICES

Introduction. CE marked construction products

Table of Contents. I Introduction 2. II Definitions & Area Calculation 2. III Room Numbering 7. IV Appendix A 9

SMOKE ALARMS CLASS 1A BUILDINGS

Little Oak, Norton Grange Little Kineton, Warwickshire

Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER:

Transcription:

Nationally Described Space Standard technical requirements Consultation draft September 2014 1

Nationally Described Space Standard technical requirements 1.Introduction 1.1 This standard deals with internal space within new dwellings and is suitable for application across all tenures. It sets out requirements for the Gross Internal (floor) Area (GIA) of new dwellings at a defined level of occupancy as well as floor areas and dimensions for key parts of the home, notably bedrooms, storage and floor to ceiling height. Requirements may be exceeded but at the very least should be met. 1.2 This standard is only applicable where a condition which is derived from a policy within a local plan is applied to a planning permission. This standard should be read alongside relvant guidance set in National planning policy. 1.3 The requirements of this standard for bedrooms, storage and internal areas are relevant only in determining compliance with this standard in new dwellings and have no other statutory meaning. The methodology used to calculate this standard is set out at Annex A. Using the space standard 1.4 The standard GIAs as set out in Table 1 are organised by storey height to take account of the extra circulation space needed for stairs to upper floors, and deals separately with one storey dwellings (typically flats) and two and three storey dwellings (typically houses). 1.5 Individual dwelling types are expressed with reference to the number of bedrooms (denoted as b ) and the number of bedspaces (or people) that can be accommodated within these bedrooms (denoted as p ). A three bedroom (3b) home with one double bedroom (providing two bed spaces) and two single bedrooms (each providing one bed space) is therefore described as 3b4p. 1.6 This allows for different combinations of single and double/twin bedrooms to be reflected in the minimum GIA. The breakdown of the minimum GIA therefore allows not only for the different combinations of bedroom size, but also for varying amounts of additional living, dining, kitchen and storage space; all of which are related to the potential occupancy. 1.7 Relating internal space to the number of bedspaces is a means of classification for assessment purposes only when designing new homes and seeking planning approval (if a local authority has adopted the space standard in its Local Plan). It does not imply actual occupancy, or define the minimum for any room in a dwelling to be used for a specific purpose other than in complying with this standard. 2

1.8 Minimum floor areas and room widths for bedrooms and minimum floor areas for storage are also an integral part of the space standard. They cannot be used in isolation from other parts of the design standard or removed from it. 1.9 The GIA of a dwelling is defined as the total floor space measured between the internal faces of perimeter walls 1. This includes partitions, structural elements, cupboards, ducts, flights of stairs and voids above stairs. GIA should be measured and denoted in square metres (m 2 ). Compliance 1.10 Drawings of at least 1:100 scale showing overall GIA, room dimensions and heights should be provided for plan checking purposes. 1.11 Confirmation of plan compliance may be checked by the local planning authority setting the condition. Planning authorities should also accept type approval and compliance of plans where this is confirmed by a building control body (which can be either a Local Authority Building Control Body, or a Government Approved Inspector) providing that the information used to asses compliance is submitted alongside the statement of compliance, to enable on site checking by the local authority 1 The internal face of a perimeter wall is defined as the brick/block work or plaster coat applied to the brick/block work. For a detached house, the perimeter walls are the external walls that enclose the dwelling, and for other houses or apartments they are the external walls and party walls. 3

4. The Nationally described Space Standard 4.1 The Internal Design Standard requires that: a. every dwelling provides at least the gross internal floor area and built-in storage area set out in Table 1 b. every dwelling with two or more bedspaces provides at least one double (or twin) bedroom c. in order to provide one bedspace, every single bedroom has a floor area of at least 7.5m 2 and is at least 2.15m wide d. in order to provide two bedspaces, every double (or twin bedroom) has a floor area of at least 11.5m 2 e. one double (or twin bedroom) is at least 2.75m wide and every other double (or twin) bedroom is at least 2.55m wide f. any area with a headroom of less than 1.5m is not counted within the GIA unless used solely for storage (if the area under the stairs is to be used for storage, assume a general floor area of 1m 2 within the GIA) g. any other area that is used solely for storage and has a headroom of 900-1500mm (such as under eaves) is counted at 50% of its floor area, and any area lower than 900mm is not counted at all h. the minimum floor to ceiling height of the main living space is 2.5m for at least 75% of the Gross Internal Area. Table 1 - Minimum gross internal floor areas and storage (m 2 ) number of bedrooms number of bedspaces 1 storey dwellings 2 storey dwellings 3 storey dwellings studio 1p 39 (37)* 1.0 built-in storage 1b 2p 50 58 1.5 3p 61 70 2b 4p 70 79 2.0 4p 74 84 90 3b 5p 86 93 99 2.5 6p 95 102 108 5p 90 97 103 6p 99 106 112 4b 7p 108 115 121 3.0 8p 117 124 130 6p 103 110 116 5b 7p 112 119 125 3.5 8p 121 128 134 7p 116 123 129 6b 8p 125 132 138 4.0 Notes: 1. GIAs for one storey dwellings include enough space for one bathroom and one additional WC (or shower room) in dwellings with 5 or more bedspaces. *Where a studio has a shower room instead of a bathroom, the floor area may be reduced from 39m 2 to 37m 2, as shown bracketed. 2. GIAs for two and three storey dwellings include enough space for one bathroom and one additional WC (or shower room). 3. Built-in storage areas are included within the overall GIA and include an allowance of 0.5m 2 for fixed services or equipment such as a hot water cylinder, boiler or heat exchanger. 4

Annex A: Methodology for generating the minimum gross internal floor areas Principles of the Nationlally Described Space Standard 1. This document sets out the methodology used to generate the Gross Intenral Areas within the Nationally described Space Standard. Use of this methodology is not required in demonstrating compliance with the standard. The space standard was developed to rationalise existing space standards into a single national approach. The starting point is the need for rooms to be able to accommodate a basic set of furniture, fittings, activity and circulation space appropriate to the function of each room. The overall objective is to ensure that all homes are highly functional in terms of meeting typical day to day needs at a given level of occupation. 2. The space standard also takes into account the spatial implications of providing improved accessibility and adaptability, particularly for older or less mobile people, and is capable of accommodating the requirements of both Category 1 and Category 2 accessibility standards in Approved Document M (2014). 3. The space standard sets out a comprehensive range of one, two and three storey dwelling types with one to six bedrooms and up to eight bedspaces (as well as studio flats). Detailed calculation methodology 4. The Gross Internal Areas in Table 1 are determined by a combination of the space needed to accommodate the furniture detailed in Annex B (which is derived from the Housing Quality Indicators and the London Housing Design Guide) and the accessibility requirements of M4(2) of the 2014 version of Approved Document M. They therefore reflect the individual room areas and the amount of general circulation and storage space needed to accommodate these cumulative requirements in a range of dwelling types and sizes. 5. The GIA reflects the principle that more people (or bedspaces) need more space but there are other variables which affect the amount of space needed for any given home to be functional. 6. The variables are as follows: 1. The number of bedspaces (or people) 2. The number of bedrooms 3. The number of bathrooms 4. The number of WC/cloakrooms (and shower rooms) 5. The number of storeys 7. Each of these variables also has an impact on the amount of circulation space and the area taken up by internal partition walls within each dwelling type. 5

8. By assigning a numerical value to each variable, the Gross Internal Areas (GIAs) can be generated by a simple calculator which has an in-built starter figure. The starter figure varies for one, two and three storey homes and takes account of any extra space needed for stairs; effectively dealing with variable 5. It also includes a basic allowance for living, dining and kitchen space, storage and general circulation and partitions. 9. Using the appropriate version of the calculator 2, only the number of bedspaces, bedrooms, bathrooms and WC/cloakrooms need to be entered for any dwelling type. These values are added to the starter figure to produce the required Gross Internal Areas. 10. Each bedspace/person has a value of 9m 2. This is made up of 2m 2 of living/dining/kitchen space, 0.5m 2 of storage space and 4m 2 of bedroom space (the difference between the size of a single and a double or twin bedroom). The remaining 2.5m 2 is attributable to extra circulation and partitions. 11. Each bedroom adds a further 4m 2. This allows the different spatial implications of various combinations of single and double/twin bedrooms to be reflected in the minimum GIAs. Independently of the number of bathrooms, WCs or storeys, these two variables together generate a simple pattern. 2b3p to 2b4p add 9m 2 2b4p to 3b4p add 4m 2 2b4p to 3b5p add 13m 2 (9+4) 3b5p to 3b6p add 9m 2 3b6p to 4b6p add 4m 2 3b5p to 4b6p add 13m 2 (9+4) 12. Each bathroom has an incremental value of 5m 2 and each WC/cloakroom or shower, 3m 2. These, and the bedroom values, also include a small further allowance for the extra circulation and partitioning that is needed when any extra room is added. 13. It should be noted that the GIAs for two and three storey homes are based on the provision of a compact winder stair. Where straight stair flights are required, more floor space may be needed. 14. The areas for one bedroom homes (which have no spare room ) incorporate an additional allowance to ensure that they are suitable for people who wish to work from home and/or older people who choose to downsize. 15. The GIA s in this standard will not be adequate for wheelchair housing (Category 3 homes) where additional internal area is required to accommodate increased cirucualtion and functionality to met the needs of wheelcahir households. 2 The calculator used to generate these figures was originally developed by Levett Bernstein Architects in 2009. The GIA s used in this standard have been calculated by Levett Bernstein Architects for DCLG. 6

Annex B: Furniture schedule used to generate the minimum gross internal floor areas Diagrams based on HQI and London Housing Design Guide 2010, courtesy of Greater London Authority 7

Diagrams based on HQI and London Housing Design Guide 2010, courtesy of Greater London Authority 8