CRITICAL POWER MONITORING CPM20/CPM21 DETAILS



Similar documents
Application Note: Monitoring Branch Circuit Loads in Critical Facilities

Energy Savings in the Data Center Starts with Power Monitoring

Power Commander Power Distribution Units from Wiremold/Legrand offer

Panorama Electricity meters For reliable values of energy consumption

How To Power A Bladecenter H Servers

A project to optimise quality and energy efficiency must include metering

API Marine. BMS Presentation. Ballast Measurement Systems

Power & Environmental Monitoring

Application/Connection Examples

Energy Management Solutions

Installation Guide Solar Connect-11

APC 3Phase Power Distribution

Simple Electrical Utility Cost Allocation Solutions

Eaton s E-Series protective relay family

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

ED1259R5 Updated April 2011 For latest specs visit

Rack Power Distribution

Electrical Network Management System

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

Smart-UPS On-Line 230 V

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

ELECTRICAL INSPECTION BULLETIN (Effective )

Current Transformer (CT) Selection Guide

OVR-3SP Recloser with PCD Control Style Guide 1VAL SG March 30, 2009 Revision B

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.

Limited Service Fire Pump Controllers Features

in widespread use with Simplex sister Company, Simplex Onsite, providing nationwide load bank rentals.

Power Distribution in Data Centers: STARLINE Track Busway, PX ipdus and Power IQ

RELIABLE AND FLEXIBLE POWER FOR YOUR DATA CENTRE

Intelligent Power Distribution in the Data Center

Applications. diris_826_a_1_gb_cat

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

Types of Electrical Meters in Data Centers

Power Meter Series 700

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Rack Power Distribution. Worldwide

Best Practices Guide for Obvius Data Acquisition Products

Packet Power. Data Center Solutions. Packet Power for Data Centers. Benefits. Features. The Packet Power Solution. Data Center Monitoring Made Easy

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

OVR Three-Phase Recloser and PCD Control Style Guide 1VAL SG October 13, 2009 Revision F

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

10 Port L2 Managed Gigabit Ethernet Switch with 2 Open SFP Slots - Rack Mountable

8 Intelligent PDUs. Intelligent Power Distribution Units for Data Centers

NEW. Solar-Log & GE Meter Residential Solar PV Monitoring & Metering Built into a Single Device

IP DSLAM IDL Quick Installation Guide

Cable Specifications. T3 Trunk Cabling APPENDIX

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

Products and solutions for pumping, irrigation and piping

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

MINIMAT-EC-Servo Screwdriver Spindles

scalable data centre energy management solution

Product Information Sheet UH36 Hi Pot Tester

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

How can a charging station for electric vehicles be set up simply and safely?

CS-24HEK4B3H2 (Master) CL-24HEK4B3H2 (Expansion) Key Features. Inputs

Communicate and view data from meters with one simple device

National Craft Assessment and Certification Program S P E C I F I C A T I O N S

IntesisBox Modbus Server SAMSUNG Air Conditioners

Product overview mm. 100 mm

USB 3.0 Cables. Color. Black Black Black Black Black Black Black Black Black Black

Energy Communication Unit (ECU)

Model #: SMART2200CRMXL

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

Remote Monitoring and REC 501 Control Unit Product Guide

EATS16 EATS16N. Installation and user manual ENGLISH. Copyright 2015 EATON All rights reserved.

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

TruPower-Portable-500W. Solar Starter kit

Current Monitoring Kit QUICK START GUIDE

MAJORSINE Power Inverter

OPL BASIC. Dosing System for Professional Laundry machines. Contents

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify.

4-Port 10/100Mbps with PoE + 1-Port 100FX Industrial Ethernet Switch Wide Temperature

Current Monitoring Kit

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design

Automatic AES Change-Over

Distributing Power to Blade Servers

Low Voltage Products

MCR1900 Media Converter 19-Slot Chassis

SECTION WEB-BASED POWER MONITORING COMMUNICATIONS SYSTEM

Microcor Wireless Transmitter (MWT)

Packet Power. Data Center Solutions. Packet Power. Packet Power for Data Centers. Benefits. Features. The Packet Power Solution

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

IFS SP-PoE Splitter User Manual

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

ABB PSPS Erich Steinmann; Generator control-2013

Transcription:

CRITICAL POWER MONITORING CPM20/CPM21 DETAILS The Starline Critical Power Monitor (CPM) is a distributed data acquisition system that enables Current and Power monitoring in busway systems. Each phase and neutral may be monitored independently. The CPM may be incorporated at a power feed point or directly into a plug-in unit. CURRENT TRANSFORMERS Current transformers (CT s) are supplied and calibrated with the unit for installation onto the customer-supplied feeder cables. Sense leads from the CT s connect to the Meter. METER MODULES Each unit is calibrated for accuracy within 1% to meet ANSI Revenue Grade Standards. CPM20 - BASIC PACKAGE Provides current measurements and alarms of up to 3 circuits. Includes Ethernet and Modbus ports; supports wireless option. CPM21 ENHANCED PACKAGE Provides current and voltage inputs, monitoring Current, Voltage, Power, Power Factor, Frequency, Apparent Power, Energy kwh, Reactive Power, Temperature, Neutral current, Power Min. and Max. DISPLAY (OPTIONAL) The bright LCD touch screen displays all basic power measurements and alarms. Touch screen provides limited configuration and control. Large format display is easily readable at a distance. COMMUNICATION Ethernet and Modbus RTU ports are standard. Ethernet port provides an Embedded Web (html) Interface & supports SNMP. Wireless mesh network interface is optional, providing true versatility in the busway environment. The Power monitor can be used to manage and maximize power distribution within a three phase power system. It can be employed as a component to help balance three phase power distribution between each phase. This assures accuracy within power usage calculations; increase efficiency by reducing wasted power on incoming power and/or neutral lines, and enables a user to fully utilize the power supplied to them. POWER FEED MONITORING CPM incorporated in or near the power feed unit provides load monitoring of the entire run of busway. Used in conjunction with BMS systems to ensure busway is not overloaded as well as for general power management. Typically uses the CPM21 Enhanced package with display. BRANCH CIRCUIT MONITORING CPM incorporated into each plug-in unit monitors individual branch circuits. Used in conjunction with BMS system for general power management and revenue purposes at the rack or circuit level. Typically uses the CPM20 basic unit for most efficient cost and packaging. Monitors up to 3 circuits. BUILDING MANAGEMENT INTERFACE Starline CPM is easily interfaced with BMS systems. Many BMS systems offer drivers for use with the Starline CPM. Contact your BMS supplier or Starline Engineering for more information. MONITOR PART NUMBER (Appends to Base Unit p/n as required) (Base Unit) - M21(xx)(yyy)/(z) No. of circuits (1-4) Max Amps/circuit(60,250,400) R: Remote Communications W: Wireless Communications DR or DW: with Display M20 or M21

POWER FEED UNIT with CPM Monitor End Feed with Installed Standard End Power Feed units connect to the male end of the Busway. Factory assembled unit consists of a 12 X 16 X 5 in. steel junction box, with removable sides, connected to a 1 foot section of Busway. The assembly includes connection lugs, ground lug and shrink tubing for wires up to 300 MCM. End Feed units for connection to female Busway ends are also available. Integral CPMs (M20/M21) installed in the End Feed provide power monitoring and alarms. Nuisance tripping may be avoided using the current information to protect against overloading phases. The monitors also assist in balance the three phase loads. A buzzer is provided that activates at 80% of full load. This level may be changed in the field using the embedded webpage. R versions provide remote communication functions, W provides wireless, DW include both local display and wireless and DR both local display and remote Special need power feed units for confined spaces that may be found in Mission Critical Data Centers can also be designed and fabricated, requiring minimum quantities. STANDARD END FEED (x = 20 or 21, yy = R, W, DW, or DR) EF225-4-Mxyy225/4 EF100N-4-Mxyy100/4 EF100NG-4-Mxyy100/4 EF225G-4-Mxyy225/4 MALE END FEED EF225-4M-Mxyy225/4 EF100N-4M-Mxyy100/4 EF100NG-4M-Mxyy100/4 EF225G-4M-Mxyy225/4 MALE RIGHT LID END FEED EF225-4MR-Mxyy225/4 EF100N-4MR-Mxyy100/4 EF100NG-4MR-Mxyy100/4 EF225G-4MR-Mxyy225/4 STANDARD LEFT LID END FEED EF225-4L-Mxyy225/4 EF100N-4L-Mxyy100/4 EF100NG-4L-Mxyy100/4 EF225G-4L-Mxyy225/4 RS-485 Ethernet Page 12.33

POWER FEED UNIT with CPM Monitor End Feed with Installed Standard End Power Feed units connect to any Busway section. Factory assembled unit consists of a 12 X 17 X 10 in. steel junction box, with removable sides, connected to a 1 ft section of Busway. Ground and connection lugs for wires up to 500 MCM are included. Reverse End Feed units for connection to opposite end of Busway sections are also available. (See B400 pages.) Integral CPMs (M20/M21) installed in the End Feed provide power monitoring and alarms. Nuisance tripping may be avoided using the current information to protect against overloading phases. The monitors also assist in balance the three phase loads. A buzzer is provided that activates at 80% of full load. This level may be changed in the field using the embedded webpage. R versions provide remote communication functions, W provides wireless, DW include both local display and wireless and DR both local display and remote Special need power feed units for confined spaces that may be found in Mission Critical Data Centers can also be designed and fabricated, requiring minimum quantities. STANDARD END FEED (x = 20 or 21, yy = R, W, DW, or DR) EF400-4-Mxyy400/4 EF400N-4-Mxyy400/4 EF400G-4-Mxyy400/4 EF400NG-4-Mxyy400/4 REVERSE END FEED EF400-4R-Mxyy400/4 EF400N-4R-Mxyy400/4 EF400G-4R-Mxyy400/4 EF400NG-4R-Mxyy400/4 REVERSE LEFT RS-485 LID END FEED EF400-4R-L-Mxyy400/4 EF400N-4R-L-Mxyy400/4 EF400G-4R-L-Mxyy400/4 EF400NG-4R-L-Mxyy400/4 STANDARD RIGHT LID END FEED EF400-4-RT-Mxyy400/4 EF400N-4-RT-Mxyy400/4 EF400G-4-RT-Mxyy400/4 EF400NG-4-RT-Mxyy400/4 RS-485 Ethernet Page 12.44

OUTLET BOX UNIT for Power Feed Current Monitoring Outlet Box with Installed An M20/M21 E12 plug-in unit is installed within 100 ft of the Busway power feed. Current Transformers (CT) are installed around the feed wires and then cabled to the Outlet Box. The paddle head may be rotated in the field to change the facing of the unit. M20/M21 CPMs provide the current level and alarm status for each phase and neutral. Nuisance tripping may be avoided using the current information to protect against overloading phases. The monitors also assist in balance the three phase loads. A buzzer is provided that activates at 80% of full load. This level may be changed in the field using the embedded webpage. R versions provide remote communication functions, W provides wireless Catalog No. Description Weight OB60E12-M20R60/3-4 CURRENT MONITOR UNIT, 60A/3P, RS-232 5.0 lb OB100CE12-M21R100/4-4 CURRENT MONITOR UNIT, 100A/4P, RS-232 5.0 lb OB100AE12-M21R100/4-4 CURRENT MONITOR UNIT, 100A/4P, RS-232 5.0 lb OB100NE12-M21R100/4-4 CURRENT MONITOR UNIT, 100A/4P, RS-232 5.0 lb OB100NGE12-M21R100/4-4 CURRENT MONITOR UNIT, 100A/4P, RS-232 5.0 lb OB225E12-M21R225/4-4 CURRENT MONITOR UNIT, 225A/4P, RS-232 5.0 lb OB225GE12-M21R225/4-4 CURRENT MONITOR UNIT, 225A/4P, ISO GND. 5.0 lb OB400E12-M21R400/4-4 CURRENT MONITOR UNIT, 400A/4P, RS-232 5.0 lb OB400GE12-M21R400/4-4 CURRENT MONITOR UNIT, 400A-4P, ISO GND. 5.0 lb OB225E12-M21R425/4-4 SPLIT NEUTRAL CF M4, ABC: 225A, N: 400A 5.0 lb Options: - Replace R with W for wireless communication. - Replace M20 with M21 for Power monitoring. - replace -4 with -3 for 3-Pole units Page 12.5

CIRCUIT BREAKER UNIT for Branch Circuit Monitoring Circuit Breaker Unit with Installed Critical Power Monitor The Branch Circuit Current Monitoring Unit has the capability of monitoring a maximum of 4 single phase receptacles or a one 3-phase receptacle. The monitor has 4 channels available. Solid core current transformers (CT) are installed around the phase wires in the plug-in unit. R versions provide remote communication functions, W provides wireless, DW include both local display and wireless and DR both local display and remote Communications Ethernet and Modbus RTU ports are standard. Ethernet port provides an Embedded Web (html) Interface & supports SNMP. Wireless mesh network interface is optional, providing true versatility in the busway environment. See Power Monitoring pages for more details. Catalog No. Description CB100NHE28-L1530-4-M20R30/3 CBM225GE28-(2)L630-4-M20R30/2 CBM225GE25-(4)L630-4-M20R30/4 CB400NGHE28-L1530-4-M20R30/3 CKT. BKR. UNIT W/RECEPTS L1530, 22K CKT. BKR. UNIT W/RECEPTS - (2) L630 CKT. BKR. UNIT W/RECEPTS - (4) L630 CKT. BKR. UNIT W/RECEPTS L1530 CBDC225E28-X-L2130C-4-M20R30/3 CKT. BKR. DROP CORD UNIT W/CONN BODY - L2130C Options: - Replace R with W for wireless communication. - Replace M20 with M21 for Power monitoring.