Power Amplifier Gain Compression Measurements



Similar documents
Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Performing Amplifier Measurements with the Vector Network Analyzer ZVB

Automatic compression measurement using network analyzers

RF Network Analyzer Basics

Agilent PN RF Component Measurements: Amplifier Measurements Using the Agilent 8753 Network Analyzer. Product Note

Network analyzer and spectrum analyzer two in one

Application Note Noise Frequently Asked Questions

Basics of RF Amplifier Measurements with the E5072A ENA Series Network Analyzer

Fast and Accurate Test of Mobile Phone Boards

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

Agilent 8757D Scalar Network Analyzer 10 MHz to 110 GHz

Experiment 7: Familiarization with the Network Analyzer

Agilent 8720 Family Microwave Vector Network Analyzers

Impedance 50 (75 connectors via adapters)

Microwave. 6200B series RF and Microwave Test sets.

Improving Network Analyzer Measurements of Frequency-translating Devices Application Note

Distance-To-Fault (DTF) Measurement in 75 Ohm Systems with the R&S FSH3-TV

Basic of Load Pull Measurements Active and Passive load pull & Harmonic load pull testbench

R&S ZNBT8 Vector Network Analyzer Specifications

A Guide to Calibrating Your Spectrum Analyzer

Agilent U2000 Series USB Power Sensors

Making Spectrum Measurements with Rohde & Schwarz Network Analyzers

High Power Amplifier Measurements Using Agilent s Nonlinear Vector Network Analyzer

A Network Analyzer For Active Components

Spectrum Analyzers And Network Analyzers. The Whats, Whys and Hows...

R&S FSW signal and spectrum analyzer: best in class now up to 50 GHz

Logging of RF Power Measurements

1. The Slotted Line. ECE 584 Microwave Engineering Laboratory Experiments. Introduction:

Calibration Guide. Agilent Technologies ESG Vector Signal Generator

0HDVXULQJWKHHOHFWULFDOSHUIRUPDQFH FKDUDFWHULVWLFVRI5),)DQGPLFURZDYHVLJQDO SURFHVVLQJFRPSRQHQWV

R&S ZNC Vector Network Analyzer Specifications

Agilent 10 Hints for Making Better Network Analyzer Measurements. Application Note B

Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview

FREQUENCY RESPONSE ANALYZERS

Agilent 8753ET/8753ES Network Analyzers

R&S ZVB Vector Network Analyzer High measurement speed up to 20 GHz with two or four test ports

MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER

Engineering Sciences 151. Electromagnetic Communication Laboratory Assignment 3 Fall Term

AUTOMATIC NETWORK ANALYZER PROCEDURES FOR 5045 KLYSTRON CAVITIES * J.G. Judkins

One Port Network Analyzer

Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics

Agilent Test Solutions for Multiport and Balanced Devices

Agilent FieldFox RF Vector Network Analyzer N9923A Quick Reference Guide

Transmitter Interface Program

Noise Figure Measurement without a Noise Source on a Vector Network Analyzer

Agilent Compatibility of the U2000 Series USB Power Sensors with Agilent Instruments. Application Note

Agilent PN Extending Vector Signal Analysis to 26.5 GHz with 20 MHz Information Bandwidth

Field Calibration Software

Michael Hiebel. Fundamentals of Vector Network Analysis

How To Use A High Definition Oscilloscope

Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics

Understanding Mixers Terms Defined, and Measuring Performance

GOOD WILL Instrument Co., Ltd. All rights reserved.

Multi-Range Programmable DC Power Supplies 9115 Series

Agilent Compatibility of USB Power Sensors with Agilent Instruments. Application Note

Techniques for Precise Cable and Antenna Measurements in the Field

MATRIX TECHNICAL NOTES

Experiments Using the HP8714 RF Network Analyzer

PLANAR 304/1 Vector Network Analyzer. Operating Manual

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

AN Application Note: FCC Regulations for ISM Band Devices: MHz. FCC Regulations for ISM Band Devices: MHz

R&S ZVA Vector Network Analyzer Specifications

Recommendations for TDR configuration for channel characterization by S-parameters. Pavel Zivny IEEE GCU Singapore, 2011/03 V1.

Group and Phase Delay Measurements with Vector Network Analyzer ZVR

EN v1.2.1 TEST REPORT FOR ag/Draft n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U

HP 8970B Option 020. Service Manual Supplement

R&S ZVA Vector Network Analyzer High performance up to 110 GHz with up to four test ports

COUPLING / DECOUPLING NETWORK (CDN) FOR UNSCREENED BALANCED PAIRS

A PC-BASED TIME INTERVAL COUNTER WITH 200 PS RESOLUTION

Features, Benefits, and Operation

2. The Vector Network Analyzer

Sentinel I28 and Blackbelt Mass Flow Calibration and Verification

Antenna Measurements with the Network Analyzer. Presented by Ernie Jackson RF/uW Applications Engineer Agilent Technologies

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

ECE 435 INTRODUCTION TO THE MICROWAVE NETWORK ANALYZER

Cond-IS RF Conducted Immunity System

Scalar Network Analysis with U2000 Series USB Power Sensors

Scalar Network Analyzer

Microwave & RF Device Characterization Solutions

Release Notes. R&S ZVH4/ZVH8 Cable and Antenna Analyzer

Agilent AN 1315 Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note

HEWLETT PACKARD. HP 8510C Network Analyzer 45 MHz to 110 GHz. Unmatched excellence in microwave network analysis

R&S ZNC Vector Network Analyzer Solid performance on a future-oriented platform

Scalar Network Analysis with the HP 8590 Series Spectrum Analyzers Product Overview

A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance.

High Power Programmable DC Power Supplies PVS Series

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

DS1621 Digital Thermometer and Thermostat

Agilent AN Improving Throughput in Network Analyzer Applications. Application Note

R&S ZVA Vector Network Analyzer High performance up to 67 GHz with up to four test ports

Multi-Range Programmable DC Power Supplies 9115 Series

Broadband covering primary wireless communications bands: Cellular, PCS, LTE, WiMAX

Optimizing IP3 and ACPR Measurements

Dash 18X / Dash 18 Data Acquisition Recorder

Using R&S FSW for Efficient Measurements on Multi- Standard Radio Base Stations Application Note

EE 186 LAB 2 FALL Network Analyzer Fundamentals and Two Tone Linearity

UNDERSTANDING NOISE PARAMETER MEASUREMENTS (AN )

R&S ZVA-Z75, -Z110, -Z140, -Z170, -Z220, -Z325, -Z500 Converters Quick Start Guide

khz to 2.7 GHz Spectrum Analyzer

Transcription:

Technical Brief Power Amplifier Gain Compression Measurements GPIB Private Bus Sweep Out Sweep In Pulse In AC Mod Out Blank/Marker Out Blanking In Overview The 1 db gain compression of an amplifier describes the region where the gain drops off 1 db compared to the small signal linear region. The industry standard for specifying the gain and output power of an amplifier is the 1 db gain compression point (P1dB). By improving the accuracy of the 1 db compression point measurement, manufacturers can provide more competitive products that are not specified in an overly conservative way.

This application note describes how the fast and accurate frequency sweep of the Giga-tronics 2500B Microwave Signal Generator, combined with the power meter accuracy of the Giga-tronics Model 8003 Scalar Network Analyzer, can be used to tune amplifiers for optimum performance whilst reducing test times. Scalar Network Analyzer versus Power Meter The traditional approach to measuring gain compression is to use a power meter. A difficulty in obtaining accurate data of gain compression is the fact that amplifiers are at their 1 db gain compression point only at particular frequencies. In order to verify the worst case 1 db compression point when using a power meter, many repetitions might be necessary at different frequencies. This approach is time consuming and expensive. Power measurement at the 1 db compression point using the swept frequency method offers improved convenience over single frequency methods. Unlike single frequency methods, all portions of the band of operation can be viewed simultaneously, averting the problem of the operator overlooking potential holes that might exist in the amplifier s response. It is also possible with this method to simultaneously use the scalar network analyzer to tune gain and return loss interactively while making the measurement to obtain the best possible overall performance. Scalar network analyzers are the instruments of choice for production testing and tuning of microwave amplifiers. Scalar network analyzers allow fast, swept frequency measurement of amplifier gain, return loss (VSWR) and power output. The problem was that, historically, power measurements using scalar network analyzers were just an approximation. This was due to their inherent lack of power measurement accuracy and NIST traceable standard within the instrument. Typical power measurement accuracy for earlier scalar analyzers might range from ±0.5 db to greater than ±2.0 db. This would depend on a number of factors, such as the scalar analyzer used, sensor type, frequency range, and the power level to be measured. The Giga-tronics 8003 Scalar Network Analyzer incorporates a built-in power meter and diode sensor for performing fast, accurate power measurements. It can be viewed as a swept power meter with scalar analyzer speed, processing power and convenience. The sweep speed of the scalar network analyzer is influenced by the frequency switching speed of the signal source. For optimum frequency accuracy, the signal source needs to be a synthesized signal generator set for digital step sweep. Switching times for a typical synthesized signal generator are in the 5 to 10 ms range that can result in a sweep too slow for optimum tuning. For example, an amplifier that operates in X-band may need to be characterized from 8 to 12 GHz at 10 MHz steps. For a source stepping at 10 ms per step, the result is a sweep 4 seconds long too slow for real-time tuning. For a more optimal tuning rate of 200 ms, the step size using this source will have to be 500 MHz wide too wide to catch glitches or find the true compression point. What is needed is an accurate, fast switching signal source. The Giga-tronics 2500B series Microwave Signal Generators AN-GT147A Power Amplifier Gain Compression Measurements Page 2 of 6

provide frequency switching speeds of under 500 µs per step (as fast as 200 µs per step for 10 MHz steps) for optimum speed and measurement accuracy. With the fast frequency speed of the 2500B series Microwave Signal Generators and the power meter accuracy of the 8003 scalar network analyzer, gain compression measurements can now be made with very fine frequency resolution without sacrificing overall measurement speed or accuracy. Using this system for the example given above, the Giga-tronics 8003 Scalar Network Analyzer will measure the X-band amplifier from 8 to 12 GHz in 10 MHz steps easily in the desired 200 ms or less time frame. Description of Operation The following method allows the scalar network analyzer to be set to simultaneously display the gain and output power of the amplifier under test. The input power to the amplifier under test is gradually increased until it is determined that, at some point in the band, the amplifier s gain has decreased by 1 db. This is the first frequency and the lowest input power level at which the amplifier under test is at the 1 db compression point. The Search feature of the 8003 can be used if desired to automatically position the cursor at the -1 db point with respect to the 0 db reference. Simultaneously, the channel connected to the amplifier s output displays the power output. The cursor then provides the frequency where the 1 db compression point first occurs as well as the output power of the device. Selecting between AC and DC Detection The 8003 scalar network analyzer is able to use the AC or DC detection mode. In the AC detection mode, each point on the sweep is measured twice, once with the signal source power on and then with the signal source power off. Consequently, this method provides zeroing for each point measured. The AC detection method offers a maximum dynamic range of 90 db without the need to re-zero the sensors. It should be noted that AC detection might induce problems with amplifiers, especially those with Automatic Level Control (ALC). For such devices, switch the analyzer to the DC detection mode for best results. Configuring the 8003 SNA and 2500B Microwave Signal Generator for Gain Compression Measurements Figure 1 below, describes how to set up the 8003 scalar analyzer and 2500B microwave signal generator to perform a low power (< 20 dbm) 1 db gain compression measurement. For high power measurements, the return loss bridge is replaced with a high power coupler. Also, in order to measure the high output of the DUT, the sensor is connected to the coupled port of a high power coupler, which is terminated by a high power load. AN-GT147A Power Amplifier Gain Compression Measurements Page 3 of 6

GPIB Private Bus Sweep Out Sweep In Pulse In AC Mod Out Blank/Marker Out Blanking In Fig 1 Connections Diagram Calibration Procedure The following procedure is used to calibrate out the couplers, bridges, and filter used in the low power measurement setup. The benefit of this approach is that the user can then effectively measure absolute power at the input and output of the DUT while the sensors are connected to couplers, etc. The low pass filter is used to minimize the effect of harmonics when measuring amplifiers at the 1 db gain compression point. Connect the equipment as shown in Figure 1 above. Include the DUT, which has been turned off. Set Signal Generator Sweep Resolution On the 2500B Select [Ramp] hardkey Select [Resolution] softkey and use the [Step Size] increment key to set the resolution to 1601 points. Set Signal Generator GPIB Address Select [System] [Menu 2][GPIB Address][Step Size Increment/Decrement] and set address to 4. AN-GT147A Power Amplifier Gain Compression Measurements Page 4 of 6

Preset the 8003 Select [PRESET] [CONFIRM PRESET] Turn ON the 8003 private bus connection to the signal generator [CONFIG] [GPIB DEVICES] [PVT BUS ON/OFF] Set Device Under Test (DUT) measurement parameters Set the Start Frequency [Start] Enter DUT start parameter [GHz] Set the Stop Frequency [Stop] Enter DUT stop parameter[ghz] Set the Power Level [Power] Enter DUT input Power Level [Power On/Off] ON Set the Sweep Speed [Sweep Time] Enter sweep time Turn OFF 8003 channels 3 and 4 [CH 3] [OFF] [CH 4] [OFF] Define Channel 1 to display sensor C. Define Channel 2 to display the ratio of C/A: [CH 1] [DEFINE] [SINGLE SENSOR] [C] [CH 2] [DEFINE] [RATIO] [C/] [C/A] Set Amplifier DUT Signal Input Level Set the input power to the small signal region of the amplifier by observing that the power at the Measurement port is at least 10 db below the anticipated value of P1dB: Select [POWER] and adjust for small signal region. Normalize the gain measurement using Path Calibration and set the scale factor to 0.5 db: [CAL] [THRU] [STORE THRU A] [STORE THRU C] [SCALE] [AUTOSCALE] [0.5] [GHz/dB] Increase the input power until the trace displaying gain on channel 2 is -1 db: [POWER] Adjust for displayed gain of -1 db. AN-GT147A Power Amplifier Gain Compression Measurements Page 5 of 6

Turn off path calibration for channel 1, autoscale, and read the output power: [CH 1] [MEAS] [ABS PWR/PATH CAL] [SCALE] [AUTOSCALE] Cursor Measurement of Compression Point Turn on the cursor and set it to the maximum output power of channel 1. This is the maximum output power of the amplifier when the 1 db gain compression point is reached: [CH 1] [CURSOR] [SEARCH] [MAX] [CURSOR] Read Pc1dB Simultaneous Return Loss Measurement Note that Channel 3 may be configured for a simultaneous return loss measurement using Input B. Press the [Channel 3] key [DEFINE] key [SINGLE SENSOR] key Calibrate for return loss by pressing the [CAL] front panel key and the [SHORT/OPEN] softkey and store the short and open measurements. Channel 3 is now configured for a return loss measurement. For improved accuracy, the frequency response of the bridge should be removed by storing the characteristics in memory and using the [MEAS-TRACE N] feature of the 8003. Read the output power and return loss of the amplifier at the frequency where the 1 db compression point is reached. This method emphasizes the importance of using a swept frequency test for verifying the precise frequency where the amplifier first reaches gain compression. AN-GT147A Power Amplifier Gain Compression Measurements Page 6 of 6