Inspection and testing of portable electrical equipment



Similar documents
Safety & Environmental Protection Services Guidance Note

Maintaining portable electric equipment in low-risk environments

FIRST STOP SAFETY 1 PAT-IT. Portable Appliance Tester. User Manual. Issue 1.6

THE INSPECTION OF PORTABLE ELECTRICAL EQUIPMENT

Fire Protection Notice No. 9 ELECTRICAL SAFETY

Electrical safety for entertainers

INFRARED QUARTZ WALL HEATER

Electrical safety and you

St Peter s College ELECTRICAL SAFETY. B. University Safety Office Policy Statement S4/10, Working safely with Electricity.

Maintaining portable electrical equipment

RCD Inspection Log Book

Electrical Practices for Construction Work

GUIDE TO THE MAINTENANCE, INSPECTION AND TESTING OF PORTABLE EQUIPMENT (ELECTRICAL APPLIANCES AND TOOLS) IN THE WORKPLACE

Electrical Hazards. Power Tools. Extension Cords

HOUSING QUALITY STANDARDS (HQS)

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

NEW ZEALAND ELECTRICAL CODE OF PRACTICE REPAIR AND MAINTENANCE OF DOMESTIC ELECTRICAL APPLIANCES BY THE OWNER OF THE APPLIANCE

Heading FACT SHEET. Overview.

This Guideline does not address electrical equipment in the following categories:

OPERATING INSTRUCTIONS

Electrical Safety Plugs What are the different types of plugs? Extension Cords What are some potential hazards involving extension cords?

Data Sheet. Portable Appliance Testing

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

October Safety Subject

Section B: Electricity

CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

Annual testing programme will be reported, by the department, as part of the annual hazard review process due to be completed by 31 March each year.

Electrical Grounding. Appendix C

A better way to install PL-259 connectors on RG-8X type coax Dan Richardson, K6MHE

ENERGY AWARE. Monitor User Guide

This section gives you some helpful information and tips on running your home and the equipment in it.

In the context of this document, the following definitions apply:

Juice Box Stages 1&2 135&335 Installation Guide 5/10/08

Electrical Safety Policy

Technical Update TAA.TU Rev. 1

ALUMINUM ELECTRICAL WIRING

Instruction Manual. Cable Splicing. Models , HDF1, HDF SS1

Network Cabling Guide

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

Installation Instructions: Electrical System for Towing Hitch... 3

AMPSEAL* Automotive Plug Connector and Header Assembly

**ATTENTION** WE DO NOT PROMOTE OR ENCOURAGE YOU TO DO YOUR OWN ELECTRICAL WIRING!!! IT IS BY FAR THE MOST DANGEROUS THING YOU CAN ATTEMPT

Electrical Safety Tips. Help us keep you safe

INSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD LOW VOLTAGE TRACK LIGHTING SYSTEM

WIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS

GET SMART! GET EQUIPPED! GET OUT! Information that could save your life. Investing in your own safety. Make a plan. Be prepared.

ELECTRIC INSTANTANEOUS WATER HEATER

Experts in what we do. Portable Appliance Testing A Practical Guide.

Heat Surge Model X5C Fire Place Insert Service Manual Applies to all units w/ circuit board

DIOCESE OF LINCOLN GUIDELINES

FUEL CELL CAR SCIENCE KIT ASSEMBLY GUIDE. Battery operation instructions:

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

Installation Instructions: Electrical System for Towing Hitch...3

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

Odyssey of the Mind Technology Fair. Simple Electronics

Table of Contents. Basic Residential Phone Wiring

WIRELESS REMOTE ASSEMBLY, 24VDC, 1 TRANS,1 REC

Quartzone Infrared Quartz Tube & Metal Sheathed Electric Heaters

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

EnergySmart monitor user instructions

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

LED Par 56 Short DMX ORDERCODE 42421

HID H4 BI-XENON FITTING GUIDE. Carefully read the following notes before starting work.

Interface between Eircom Network and Additional Telephone Equipment

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE SAFETY BULLETIN #23

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

WATER LEAKS AND DAMAGE

Overheating limit control

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Inch PowerVent LED Indicator Explanations & Troubleshooting Table

ELECTRICAL PRACTICES FOR CONSTRUCTION WORK

Navico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement

Atlanta CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. IF UNSURE CONSULT A QUALIFIED ELECTRICIAN

Step by step guide to installing your own Ku Band satellite dish

Document number RS-PRD Revision 05 Date 20/10/2009 Page 1/30

Meaco 30L and Meaco 40L dehumidifier instruction manual

Manual for Fire Suppression & Methane Detection System

NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS

CoolWave r 2 Phase Control Board and Cable Replacement Kits

Does a landlord have to have an electrical inspection carried out?

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Circuit Electrical Testing

For Models #6-5001, #6-7501, # & #10-12K1

V94 BULK TAPE DEGAUSSER

School or service safety advisor (SSA) role

Determining the Cause of AFCI Tripping Branch/Feeder and Combination Arc Fault Circuit Interrupters Class 760

Subject: Circuit Board troubleshooting Bulletin

HDTV Anywhere USER MANUAL / HDTV Anywhere ALL RIGHTS RESERVED MARMITEK

OPERATING INSTRUCTIONS

Operating Instructions

Auto Sentry-eXP Maintenance

Enterprise Telephone. Model OPERATING INSTRUCTIONS

ELECTRICAL SAFETY. The standard unit for measuring electrical current.

Portable Air Conditioner

Transcription:

February 2008 Inspection and testing of portable electrical equipment This is a guidance document for Schools and Support Services. Units should use the guidance to help them develop their own local health and safety arrangements. Items of portable electrical equipment should be inspected and, if necessary, tested periodically to check that they are in a safe condition and have not been damaged or otherwise abused. In offices and related areas throughout the University the inspection and testing is arranged by the Estates Section who will usually bring in contractors to carry out the work. This will be done every 2 to 3 years. Equipment which has been inspected/tested and which is deemed to be safe will be marked with a green sticker. Computer equipment will not be tested but any multiway extension cables used with computer equipment will be tested. Schools must make their own arrangements for carrying out inspection and testing in laboratories and workshops. A similar frequency of 2 to 3 years is recommended. Technicians who have had suitable training can carry out this work. Inspection and testing of portable electrical equipment is not any more technically complex than many of the other activities which technicians carry out in laboratories. As with these other activities, Technical Resource Managers and Team Leaders should determine which of their staff are competent to carry out inspection and testing. Training and supervision should be provided as required. Audiovisual equipment will be inspected and tested by staff from DIT. There are some areas in the University where equipment needs to be tested more frequently than every 2 to 3 years. These are areas where equipment is more likely to be damaged. Examples include equipment used in kitchens, halls of residence and in maintenance activities such as grounds maintenance. Advice should be sought on inspection and testing frequencies for these higher risk areas. Studies carried out by the Health and Safety Executive have shown that around 95% of faults and damage with portable electrical equipment can be found just be looking the visual inspection. A small number of faults cannot be picked up on visual inspection, particularly lack of continuous earths. Therefore most items of earthed equipment should also have combined inspection and test to check for these other faults. Further guidance from the Health and Safety Executive is provided in their leaflet on Maintaining Portable Electrical Equipment ref INDG236 which is on the HSE website. An outline of how inspection and testing should be undertaken in a laboratory follows below.

Inspection and testing of portable electrical equipment in the laboratory Remember that the visual inspection is the most important part of the inspection and test. The HSE say that around 95% of faults with electrical equipment can be found just by looking at the equipment. Make sure that you understand the difference between earthed (or Class 1) equipment and equipment which is not earthed (Class 2 equipment). See the HSE s leaflet for details. Class 1 equipment needs both visual inspection and testing for a continuous earth. Class 2 equipment needs only a visual inspection. Extension leads should also be inspected and tested. After inspection/testing, both Class 1 and Class 2 items of equipment should be marked with a green sticker to show that they have passed. The date of inspection/test and the initials of the person carrying it out should be written on the sticker. Old stickers should be removed or defaced before new stickers are applied. Equipment which fails inspection/test should be labelled as faulty and taken out of use until it can be repaired. Inspection and testing should always be carried out by arrangements with those in charge of the laboratories concerned. Lab managers (or their equivalents) may have concerns about the testing of certain items of complex or high-value equipment. In such cases a visual inspection may be sufficient or advice on testing can be sought from those who maintain the equipment when they next visit. Supervisors should ensure that those carrying out inspection and testing have been shown how to do it and have demonstrated that that they understand how to it. This should be no different to the way in which technicians are shown how to operate any item of lab equipment, i.e. they have to demonstrate that they know how to do the task before being allowed to do it unsupervised. Equipment used for testing should be checked for calibration periodically (every 2 to 3 years is the suggested frequency for the simple testers which indicate just Pass/Fail). This should be done by an organisation which can issue a calibration certificate for the equipment. The manufacturers or suppliers of the equipment usually offer this service. Advice and assistance with inspection and testing should be sought from supervisors and line managers who can, if necessary, seek advice from the University Safety Adviser.

A Step-by-Step Guide to Visual Inspection of Electrical Equipment (reproduced here by kind permission of Safety and Environmental Protection Services at the University of Glasgow) What to Inspect? You should inspect all equipment that is portable. Generally this means equipment that has a cable and a plug that can be inserted into a 13A socket outlet. Schools should make alternative arrangements for equipment that is permanently wired to the mains (e.g. via fused outlets). The testing and inspection of the fixed wiring installation within buildings is the responsibility of Estates. When to Inspect The intervals between inspection are not fixed by legislation. Schools must determine the frequency that is appropriate to each piece of equipment based on risk. Equipment that is rarely moved and is not at risk of damage (e.g. computers) is likely to be low risk and requires less frequent inspection than equipment that is frequently moved, might be used in a damp environment (e.g. kettles, water baths) or may be subject to damage. Office equipment - levels of risk (Low to Medium) Low risk Medium risk Equipment used in an office environment is rarely of the type that would be considered high risk. High risk equipment includes equipment such as portable electrical hand tools. Non-Office Equipment - Levels of Risk (High) High risk

Who should carry out inspections? It is not necessary to have an electrician carry out equipment inspections. Many members of University staff will possess the skills to perform this task if given the correct guidance. OK so what needs to be done? By following the simple steps laid out below most staff should be able to carry out visual inspections of electrical equipment both safely and competently. Now work through each of these steps - but remember If you are in any doubt about what you are doing - STOP - and seek assistance. As the title visual inspection implies, all you really need to do is look closely at the equipment. More than 90% of equipment faults can be found by visual inspection. Step 1 - before you start inspecting SWITCH OFF THE POWER AND UNPLUG THE EQUIPMENT Never open the casing of the equipment. If you suspect there is a fault inside the casing you should seek help from someone appropriately qualified. Step 2 - the electrical cable Run the cable slowly through your hands and feel for any lumps, cuts or rough areas. At the same time inspect all round the cable whilst working down it a little section at a time. Watch out for any areas that are discoloured, this might indicate an area of damage. Be particularly vigilant with any part of the cable that may be prone to having equipment sat on it or that may be habitually curved or twisted. These are sections that are likely to become damaged. Uncover any areas of cable that have been covered (e.g. with tape or a label) as they may be obscuring joints or areas of damage. Cables should not generally have any joints that are made by means other than standard connectors. Be suspicious of any joints if they are not formed by fully enclosed, solid, standard connectors. Have them checked by someone suitably qualified. If any part of the outer insulation of the cable is breached, or if you have reason to believe that the wires within it may be damaged, refer immediately to Step 5.

Step 3 - the plug This illustration shows a correctly wired plug: Cable entry to the plug Begin your inspection of the plug by looking at the point where the cable enters it. The outer insulation of the cable should be tightly gripped by the plug cable grip and none of the thinner internal wires should be visible from the outside of the plug. Correct: Cable Entry to the Plug NOT like this: The plug casing

Next look at the plug itself. The casing should not be cracked, chipped or damaged. There should be no bent pins. If the plug is not permanently bonded to the cable you should be able to open the casing using a small screwdriver. Again look closely at the point where the cable enters the plug through the cable grip, this time examining it from the inside of the plug. As before, the outer cable should be securely gripped and the thinner inner cables should emerge from the outer only beyond this point. The wires within the plug Next examine each of the individual thinner cables. It is not necessary to unwire the plug to do this. Make sure that the BROWN wire (RED in older equipment) is connected to the LIVE terminal (usually labelled L), that the BLUE wire (BLACK in older equipment) is connected to the NEUTRAL terminal (usually labelled N) and that the GREEN and YELLOW wire is connected to the EARTH terminal (often labelled E, this is at the top of the plug). Ensure that there are no damaged parts on any of the cables and make sure that there is no excess cable that may snag or be trapped when the plug is re-assembled. If any of the smaller cables are too long you may see rub or pinch marks on the outer insulating surface. You should check the point where the inner wires are connected to the plug terminals and ensure that there is not an excessive amount of bare wire exposed. Ideally the insulating outer should cover the inner conducting wire entirely and no conducting wire should be visible. In practice this is often difficult to achieve and it may be necessary to have a gap of about one millimetre of conductor showing between the insulating material and the terminal. Finally check the connections at each terminal. Ensure that the conducting wire is securely housed and that no stray wires are sticking out. Make sure that the terminal screws are securely tightened. What if there are only two wires inside the plug? Remember that some appliances have a cable that contains only two wires (e.g. some desk lamps). If you see only two wires when you open the plug take a close look at the end of the cable where these wires emerge. Make sure that there isn't a third wire that has been cut off. You should also check that the two wires are connected correctly. This means that the BROWN (RED in older equipment) wire should be connected to the LIVE terminal and the BLUE (BLACK in older equipment) wire to the NEUTRAL just as they are when three wires are present.

In this case the only wire that should be missing is the GREEN and YELLOW connection to the EARTH terminal. A two wire plug: Is there more than one plug on the cable? In some cases the cable may not be permanently fixed into the equipment but may have a plug or connector for that purpose. In this case you should also examine this for any sign of damage and to ensure that the outer cable is securely held in such a way that the inner cables are not visible. It is usual for this type of connector to be sealed and as a result no internal inspection is possible. An example of a two plug lead: Step 4 - the fuse Any plug that is designed to make a connection between a piece of equipment and a mains socket should be fitted with a cartridge fuse. In the case of sealed plugs this fuse is located in a compartment that can be opened from outside the plug. This compartment is located on the face of the plug from which the pins protrude. In unsealed plugs the fuse is located inside the body of the plug and is connected to the LIVE terminal next to the BROWN wire. When you open an unsealed plug to inspect the cables and connections the fuse should be readily visible.

In sealed plugs the fuse is accessed from a compartment located between the plug pins. An example is shown below: When carrying out a visual inspection you should ensure that the plug has a fuse and that it has not been replaced by some other device (such as a piece of wire or silver foil). It is also necessary to make sure that the fuse is of the correct type (rating). As a general rule, most office equipment should be fitted with a 5 amp fuse. Heaters, kettles etc and appliances that use more power often require a 13 amp fuse.

The following table gives an indication of the fuse that should be used in some of the more common office equipment. Equipment type = Fuse rating Equipment Type Suggested Fuse Rating (Amps) Desk lamp 3 Kettle 13 Electric Fire 13 Computer 5 Vacuum Cleaner 13 It is possible to calculate the fuse rating required for equipment if you know how much electricity the equipment uses. Most equipment has a small plate or label (usually on the base or rear panel) giving the energy usage. This is expressed as a certain number of WATTS (the initial W is frequently used as an abbreviation) for example a desk lamp may say 100W maximum. If you know the energy usage then the correct fuse rating can be calculated using the table below: 'Wattage' of Equipment = Fuse Rating 'Wattage' of Equipment Fuse Rating Up to 600 Watts 3 Amps Between 600 Watts and 1000 Watts (1KW) 5 Amps Between 1KW and 3KW (3000 Watts) 13 Amps Step 5 - Putting the equipment back into service No faults observed If you have found no faults it is now a simple matter to reassemble the plug. Before putting the equipment back into use you should label the plug or the equipment to show that an inspection has been carried out. This label should give details of the date of inspection and who carried out the inspection. Proprietary labels may be purchased, but it is perfectly acceptable to use self-adhesive labels so long as they remain attached until the next inspection. A possible label layout for showing that equipment has been inspected is Electrical Appliance Inspection Date: 17/05/2000 Inspected by: Mary Smith, Astrophysics Dept.

If you found one or more faults: If you found any of the following simple faults you are likely to be competent to correct them by yourself: Incorrect fuse Missing fuse Connections inside the plug are loose Outer cable is not gripped tightly by the cable grip. After a little practice most people are able to rewire a plug if they have the correct equipment. If you do not have the correct equipment to do this job, or if you feel it is beyond your ability you should seek assistance. If the cable is damaged you should not attempt to repair this and should seek assistance. If you have identified faults during the inspection that cannot be immediately fixed then the equipment should be taken out of service until the necessary repairs can be undertaken. This can be achieved by removing it to a secure storage area. If this is not possible the plug should be removed to prevent use. In all cases the equipment should be labelled to indicate that it should not be used. Just before you go.. Why don't you try the quiz. See if you can spot the faults in the plugs shown below. You'll find the answers at the end. Plug A Plug B

Plug C Answers: Plug A - no outer cable sheath and live and neutral wires reversed. Plug B - plug broken and taped up Plug C - wire wrapped round fuse, live wire (brown) too long, protective sheathing cut too far back on earth wire (yellow and green) and so too much wire is exposed.