Panorama Electricity meters For reliable values of energy consumption



Similar documents
Main catalog. Electricity meters For modular enclosures and DIN rail

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

B21 User Manual Document ID: 2CMC485004M0201 Revision: A

Counter for Energy. We make energy measurable and secure your future.

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

A project to optimise quality and energy efficiency must include metering

Applications. diris_826_a_1_gb_cat

Quick Connect. quick - simple - efficient.

CRITICAL POWER MONITORING CPM20/CPM21 DETAILS

Metering for today s systems

/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.

Simple Electrical Utility Cost Allocation Solutions

Power Meter Series 700

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

Electrical Measuring Instruments

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

NEW. Solar-Log & GE Meter Residential Solar PV Monitoring & Metering Built into a Single Device

M2M The measure of efficiency

PCS0100en Persy Control Services B.V. Netherlands

TX2123 RS485 TO ETHERNET ADAPTOR

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

securityprobe 5E Standard

Uninterruptible Power Supply

How To Use A Powerbook 2.2 (Powerbook 2) For Free On A Computer Or Ipad (Powerware) For A Week Or Two (For A Week) For $99.99 (For An Extended Period Of Time)

Process Alarm Solutions

Application/Connection Examples

Optimize your simple machines... Modicon M218 Selection Guide

Remote Monitoring and REC 501 Control Unit Product Guide

Low Voltage Products

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

Energy meters For an efficient control of energy consumption

Passion for KNX innovation

Waveguide Access Point WGA631. Product Guide

securityprobe5es -X20

/ The personal storage solution for 24H Sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected

MID Guide onsultancy eters

PRO370D 65A Mbus MID DIN rail three phase four wire energy meter. User manual Version 1.03

INTEGRAL REMOTE MANAGEMENT SOLUTION cirwatt b series

ABB central inverters PVS to 1000 kw

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

Compatible with all of the Ravica range of Intelligent Sensors it provides a complete environmental, access control and security monitoring solution.

Power Xpert Gateway 800E

PowerCommand iwatch 100 Remote Network Monitoring

NXL Series Inverters. HVAC Inverters made simple

Unidirectional Transmitter/ Receiver Units Introduction

SECTION 16002C CAMPUS CENTRAL METERING SYSTEM DESIGN CRITERIA 1. General

Indoor / Outdoor Antenna

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

API Marine. BMS Presentation. Ballast Measurement Systems

PE8216/PE8324. Energy Intelligence Solutions

Energy Management Energy Meter Type EM23 DIN

Power monitoring unit type VAMP 260

KNX Panasonic Air Conditioners

Application Note: Monitoring Branch Circuit Loads in Critical Facilities


Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Temperature & Humidity SMS Alert Controller

March 15th 2005 EI Solutions - Submetering 1

IntesisBox Modbus Server SAMSUNG Air Conditioners

Using installed Fieldbus Wiring to carry Ethernet Communications

HYBRID POWER SYSTEMS for TELECOM applications

ACR120 Technical Specifications version 2.9 November 2005

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

Monitoring,Telemaintenance,... HACCP. Innovative Supermarket solutions. Tecnologia ed Evoluzione

SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY. Apparent Power Control (APC) unique micro inverter with

EFC Frequency converters

idom Powered by OMNICON Srl

scalable data centre energy management solution

EDM Cloud Remote Monitoring Solutions. Crystal Instruments, January 2014

System Components EMIS Central Unit. Central Unit. Description

Automatic Transfer Switch-Controller ATS-C by Eaton. Automatic Transfer Switch- Controller ATS-C 96 and C 144

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Foxboro Evo Process Automation System

Case Study - University at Buffalo State University of New York. Lower Energy Usage Costs with Real Time Monitoring, Campus-wide

NC-12 Modbus Application

Digital input modules

MONITORING ELECTRICITY, WATER, SOLAR AND GAS

Disturbance Recoder SPCR 8C27. Product Guide

Static energy meters

Labkotec SET. Labkotec separator alarm system protecting our environment. Measure your success

Technical Information POWER PLANT CONTROLLER

Environmental data Temperature: -20 C to +55 C (Operating) -55 C to +85 C (Storage) Humidity: 0 95%

Reducing Energy Costs with Peak Shaving in Industrial Environments

PN5212/PN5320/PN7212/PN7320

ENERGY AUDITING AND MONITORING IN COMPANIES

EN54-16 Voice Alarm System PRODUCT DATASHEETS

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Eaton s E-Series protective relay family

Transcription:

Panorama Electricity meters For reliable values of energy consumption

Why measure Electrical Energy Energy cost is on the rise. It is therefore in the interest of both private and commercial customers to measure energy. If you know your consumption, you are able to be energy efficient and ultimately save money. By using EQ meters from ABB it is possible to know and control consumption over time, in addition you measure cost for fair distribution/sharing. This is valid for commercial buildings, such as shopping malls and airports, for industries as well as for residential buildings. Another reason to measure energy is obvious saving the environment. By having full control over your consumption you will be able to cut on you CO2 emissions. New legislations and standards like ISO 50001 call for more control over your energy consumption and EQ meters from ABB will provide the electrical energy consumption data for both initial analysis and later on also monitoring the result. Why EQ meters from ABB EQ meters from ABB comes with a pedigree of quality and front line technology since the first ever DIN rail mounted meter produced by us in 1984. We drive the technology further and offer a wide modern range of electricity meter from small meters for basic usage up to advanced meters for demanding Customers. By using the flexible interface for communication you are able to see and control your consumption in a very efficient way. With the optional tariff handling functions EQ meters from ABB helps you on the way to accurate cost distribution even when complex tariff schemes are used. A lot of functions fit inside EQ meters from ABB despite its compact design and small dimensions. They are very easy to add or retrofit into your standard enclosure - the installers best friend. All our meters deliver reliable values even in harsh environments, both electrical and ambient. EQ meters is a part of the well-known ABB quality from a reliable supplier. You can simply trust an EQ meter to supply the correct value. Common features DIN rail mounted MID Wide temperature range Logical interface Instrumentation (P, U, I, Pf) Pulse output

Product overview Number of phases Three phases Single phase Meter type A43 B23 C13 A44 B24 A41 B21 C11 A42 Connection Direct connected Transformer connected Direct connected Transformer connected Nominal voltage 3 x 230/400 V AC 3 x 230/400 V AC 230 V AC 230 V AC Frequency 50 or 60 Hz 50 or 60 Hz 50 or 60 Hz 50 or 60 Hz Voltage (V AC) phase to neutral phase to phase 3 x 57,7-288 3 x 100-500 3 x 220-240 3 x 380-415 3 x 57,7-288 3 x 100-500 3 x 220-240 3 x 380-415 57,7-288 220-240 230 57,7-288 Accurcy class (active energy) Class 1 (B) Class 1 (B) or Class 0,5 S (C) Class 1 (B) Class 1 (B) or Class 0,5 S (C) Maximum current 80 A 65 A 40 A 6 A 80 A 65 A 40 A 6 A Reference current 5 A 1 A 5 A 1 A DIN modules 7 4 3 7 4 4 2 1 4 Meter type A43 B23 C13 A44 B24 A41 B21 C11 A42 Pulse output Alarm Reactive energy Four quadrant measurements Steel Steel Steel Steel Bronze Bronze Bronze Bronze Resettable register 2 inputs and 2 outputs Up to 4 tariffs - controlled by externa signal or communication Up to 4 tariffs - controlled by internal clock Basic clock functions Silver Silver Silver Silver Gold No Gold No Gold No Gold Advanced clock functions Harmonics and THD Platinum Platinum Platinum Platinum Configurable I/O In-built communication M-Bus Option Option Option Option In-built communication RS-485 (Modbus RTU or EQ bus) Option Option Option Option KNX module via IR port Available 2014* ) Available 2014* ) Available 2014* ) Available Meter type A43 B23 C13 A44 B24 A41 B21 C11 A42 * ) Available from 2014 For ABB current/voltage transformers range, please see System prom catalog 2CSC400002D0208 For further information, see catalog 2CMC480022C0003

Communication network EQ meters EQ s bu -t w is t ed pa ir DELTA/ODIN generation meters wi st ed pa ir IR M -B us -t External communication The EQ meter gateway is used as an access point to all of the EQ meters and allows the user to perform settings using high level programming language JSON or through a web browser. When safety and maximum functionality is of importance the EQ bus will make it fully utilized over the EQ meter gateway. Meters with RS-485 can be used for Modbus or EQ bus. General features The gateway is the interface between EQ meters and the system side. The gateway features both RS-485 and M-Bus interfaces towards the meter side. On the up-stream side there is a RJ 45 connector for Ethernet. Security is ensured on the Ethernet by the use of SSL encryption. This QR-code is linked to the latest version of our folder 2CMC481006B0201 in PDF format. You will have to download a QR-code reader app to your phone in order to use it.

Features C series HVAC applications Stand alone applications Domestic applications Charging stations Single phase or three phase Very compact, 1 & 3 modules. Direct connected up to 40 A Active energy measurement Instrument values Accuracy class 1 Alarm function Optional MID B series Cost transfer/billing Solar power Elevators/escalators Lighting Installation on machines Single phase or three phase Direct connected up to 65 A or CT connected (three phase types) Active energy measurement Class B (Cl. 1) or Class C (Cl. 0,5 S) Alarm function MID Reactive energy measurement Import/export measurement of energy Optional communication via M-Bus or RS-485 1) 4 tariffs controlled by input or communication A series Facility management installations Critical power Production lines System solutions Power quality Single phase or three phase Direct connected up to 80 A or transformer current- and/or voltage transformers (CTVT) Active energy measurement Class B (Cl. 1) or Class C (Cl. 0,5 S) on CTVT connected meters Wide voltage range 100-500 V phase to phase 57,7-288 V phase to neutral Alarm function MID Reactive energy measurement Import/export measurement of energy Optional communication via M-Bus or RS-485 1) 4 tariffs controlled by inputs, communication or built-in clock Previous values (by day, week or month) Demand measurement (max and min) Load profiles (8 channels) Harmonics measurement up to 16 th harmonic and evaluation of THD Gateway Meter management/configuration Remote reading of meter data Integration of meters in system solution Connection to meters via RS-485 EQ bus Connection to meters via M-Bus Ethernet connection (https, JSON) Built-in webserver Meter readout via webserver Meter configuration via webserver Upgradeable 1) For Modbus RTU or EQ bus

Contact us ABB AB Meters Box 1005 SE-611 29 NYKÖPING, Sweden Phone: +46 155 29 50 00 Fax: +46 155 28 81 10 www.abb.com/lowvoltage Copyright 2013 ABB. All rights reserved. Specification subject to change without notice. This QR-code is linked to our web site www.abb.com/lowvoltage. You will have to download a QR-code reader app to your phone in order to use it. This QR-code is linked to the latest version of our catalog in PDF format. You will have to download a QR-code reader app to your phone in order to use it. Panorama 2CMC481005B0201, June 2013, Ver A, Prod ABB AB, Meters/XM