SeMSy III Failover Server

Similar documents
Recording Server Module BANK

Server Rack Commissioning

AXIS Camera Station Quick Installation Guide

Video Recording and Video Analysis DVS1600

MySabre with Sabre VPN

User Manual. Software SmartGUI. Dallmeier electronic GmbH & Co.KG. DK GB / Rev /

INSTALLATION GUIDE. AXIS Camera Station

Remote Backup Software User Manual V 2.0

Operation. English. Recording Server PRELOADED. Rev /

Hardware/Software Specifications for Self-Hosted Systems (Multi-Server)

Dell Statistica Statistica Enterprise Installation Instructions

V2.7.x Installation on a Database Server Note: This document is to be used on a new database server installation.

Server Installation Guide ZENworks Patch Management 6.4 SP2

RSM Web Gateway RSM Web Client INSTALLATION AND ADMINISTRATION GUIDE

CompleteView Pop Up Monitor User s Manual. Version 3.8

Avigilon Control Center Server User Guide

Recording Server Monitoring Tool

FAS Asset Accounting FAS CIP Accounting FAS Asset Inventory SQL Server Installation & Administration Guide Version

V2.8.x Installation on a Database Server Note: This document is to be used on a new database server installation.

Configuration. English. Viewing Client. Rev /

formerly Help Desk Authority Upgrade Guide

Installation Instruction STATISTICA Enterprise Small Business

NTP Software File Auditor for Windows Edition

SQL Server 2008 R2 Express Installation for Windows 7 Professional, Vista Business Edition and XP Professional.

NTP Software File Reporter Analysis Server

Avigilon Control Center 5 System Integration Guide. for Software House C Cure 9000

Monitor Wall 4.0. Installation and Operating Manual

STATISTICA VERSION 12 STATISTICA ENTERPRISE SMALL BUSINESS INSTALLATION INSTRUCTIONS

SharpdeskTM R3.1. Installation Guide Version

Installation Instructions

Quick Start Guide. GV-Redundant Server GV-Failover Server. 1 Introduction. Packing List

Data Collection Agent for Active Directory

Magaya Software Installation Guide

Global Server Installation Guide

StarWind iscsi SAN: Configuring Global Deduplication May 2012

Lepide Active Directory Self Service. Installation Guide. Lepide Active Directory Self Service Tool. Lepide Software Private Limited Page 1

Guide to Installing BBL Crystal MIND on Windows 7

MetaMorph Microscopy Automation & Image Analysis Software Super-Resolution Module

Dell Statistica Document Management System (SDMS) Installation Instructions

intertrax Suite resource MGR Web

Cloud Services ADM. Agent Deployment Guide

Recording Server Version

Product Version 1.0 Document Version 1.0-B

Active Directory Management. Agent Deployment Guide

Installing LearningBay Enterprise Part 2

footscan SCSI system Installation guide: balance software

Diamond II v2.3 Service Pack 4 Installation Manual

Installation Guide for Workstations

Fiery E100 Color Server. Welcome

STATISTICA VERSION 9 STATISTICA ENTERPRISE INSTALLATION INSTRUCTIONS FOR USE WITH TERMINAL SERVER

Remote Backup Software

IDIS Solution Suite. Streaming Service. Software Manual. Powered by

Avira Secure Backup INSTALLATION GUIDE. HowTo

IP-Pro (Virtual IP Protocol Independent Version) User Instructions

Remote Management System

Sharpdesk V3.5. Push Installation Guide for system administrator Version

ViconNet/Software House C Cure Integration

Receptionist-Small Business Administrator guide

How To Create An Easybelle History Database On A Microsoft Powerbook (Windows)

Pro-Watch Software Suite Installation Guide Honeywell Release 3.81

AW-HE60 Firmware Upgrade Procedure

CompleteView Alarm Client User s Manual. Version 3.8

License Patrol TM Mac Client Installation Guide 7.0 for Mac OS X. September 2015 VERALAB TM

InfoPrint 4247 Serial Matrix Printers. Remote Printer Management Utility For InfoPrint Serial Matrix Printers

DeviceAnywhere Automation for Smartphones Setup Guide Windows Mobile

Backing up IMail Server using Altaro Backup FS

Hardware/Software Requirements For Self-Hosting Multi Server

2. Installation and System requirements

@ptitude Observer. Installation Manual. Part No Revision G

Windows 2003 Server Installation Guide

Installation Guide v1.11 and Higher

1. Technical requirements 2. Installing Microsoft SQL Server Configuring the server settings

MGC WebCommander Web Server Manager

Polycom RSS 4000 / RealPresence Capture Server 1.6 and RealPresence Media Manager 6.6

CompleteView Alarm Client User Manual. CompleteView Version 4.3

Installation Instruction STATISTICA Enterprise Server

GUARD1 PLUS SE Administrator's Manual

IDIS Solution Suite. Backup Service. Software Manual. Powered by

IDIS Solution Suite. Backup Service. Software Manual. Powered by

PowerSchool Student Information System

Copyright. Disclaimer. Introduction 1. System Requirements Installing the software 4

1 DVR 670 Series firmware version (date )

Installing the BlackBerry Enterprise Server Management Software on an administrator or remote computer

How to Test Out Backup & Replication 6.5 for Hyper-V

File Management Utility User Guide

ivms-5200 Professional Web Manager User Manual

Impact+OCR 1.1 Readme


Administration guide. Host software WinCCU Installation. Complete gas volume and energy data management

Web Supervisor/Agent. System Requirements & Troubleshooting Guide. 989 Old Eagle School Road Wayne, PA (610)

Software Activation. high security remote access. NCP Secure Entry Client

JKW-IP. IP Video Entry System. QuikStart Guide

Compuprint 4247 Serial Matrix Printers

Topaz Installation Sheet

BlackHawk for MAC Software User Guide

Xactimate v.27 Network Installation


ManageEngine IT360. Professional Edition Installation Guide.

pco.interface GigE & USB Installation Guide

Charter Business Desktop Security Administrator's Guide

Transcription:

Installation English Video Management System SeMSy III Failover Server Rev. 1.0.0 / 2015-07-14

Information about copyright, trademarks, design patents 2015 Dallmeier electronic The reproduction, distribution and utilization of this document as well as the communication of its contents to others without express authorization is prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or design. We reserve the right to make technical modifications. The manufacturer accepts no liability for damage to property or pecuniary damages arising due to minor defects of the product or documentation, e.g. print or spelling errors, and for those not caused by intention or gross negligence of the manufacturer. Dallmeier electronic GmbH & Co.KG Cranachweg 1 93051 Regensburg Germany www.dallmeier.com info@dallmeier.com All trademarks identified by are registeres trademarks of Dallmeier electronic. All trademarks identified by * ) are trademarks of the following owners: Intel and Core of Intel Corporation headquartered in Santa Clara, California, USA; Microsoft, Windows and AvtiveX of Microsoft Corporation headquartered in Redmond, Washington, USA; Third-party trademarks are named for information purposes only. Dallmeier electronic respects the intellectual property of third parties and always attempts to ensure the complete identification of thirdparty trademarks and indication of the respective holder of rights. In case that protected rights are not indicated separately, this circumstance is no reason to assume that the respective trademark is unprotected. www.dallmeier.com 2

Table Of Contents 1 Introduction...4 1.1 Validity...4 1.2 Documents...4 1.3 Typographical Conventions...4 2 General Notes...5 2.1 Appropriate Use...5 2.2 Performance Features...5 2.3 Warranty...5 3 System Requirements...6 4 Installation...7 5 Status And Activity...18 5.1 Failover Manager Client...18 5.1.1 SeMSy III Database...18 5.1.2 Failover Server Database...19 5.2 Web Service Server...19 6 SysStart...20 www.dallmeier.com 3

1 Introduction 1.1 Validity This document applies to the installation of the SeMSy III Failover Server software. The illustrations in this document might differ from the actual product. 1.2 Documents Datasheet Technical specifications and data (for trained system integrators) Installation (this document) Instructions on installing and commissioning the software (for trained system integrators) Configuration Instructions for configuring the software (for trained system integrators) 1.3 Typographical Conventions This document may contain various warning words and symbols that indicate potential sources of danger: NOTICE NOTICE indicates practices for preventing property damage, incorrect configurations or faulty operations. For reasons of clarity and readability, various text formatting elements and types of emphasis are used in this documentation: Instructions are indicated by arrows ( ). ¾¾Carry out instructions one after the other in the sequence described. Expressions in bold/italics generally indicate a control element on the device (switches or labels) or on its user interface (buttons, menu items). Paragraphs in italics provide information on basic principles, special features and efficient procedure as well as general recommendations. www.dallmeier.com 4

2 General Notes 2.1 Appropriate Use The SeMSy III Failover Server software is a failover (hot standby) for network-based Dallmeier recording systems. The software permanently monitors the availability of all recording systems in the SeMSy III video management system. When the recording of a system is interrupted (fail of the device, loss of the network connection, HDD or RAID failure), the Failover Server switches all streams for the recording on the defined spare recording system. 2.2 Performance Features Monitoring of the availability of recording systems Definition of standby recording systems for all monitored recording systems Detection of failure of the recording system, loss of the network connection, HDD or RAID failure Instant switching of all streams for recording on spare recording systems Triggering of failover operation indicators on SeMSy III Workstations 2.3 Warranty The terms and conditions valid at the signing of the contract shall apply. www.dallmeier.com 5

3 System Requirements In order to install a SeMSy III Failover Server the following requirements must be met: Operating system Microsoft *) Windows *) 7 / 8 (32- / 64-bit) Processor (CPU) Intel *) Core *) i3 at least 2.5 GHz or comparable Memory (RAM) DDR3, minimum 4 GB Graphics card (GPU) VGA compatible Resolution 1600 1200 (4:3, UXGA) or 1920 1080 (16:9, Full HD) Ethernet 100 Mbps Storage 500 MB Miscellaneous SeMSy III Setup Server www.dallmeier.com 6

4 Installation The SeMSy III installer setup installs all the necessary components on your system. A SeMSy III Failover Server gets its settings automatically by a SeMSy III Setup Server, which is administered by the software SeMSy DB ConfigTool (see the documentation Configuration for SeMSy III ). Note before the start that administrator rights are required for installation. that a SeMSy III Setup Server must be available and accessible over the network. Follow the steps below in order to install a SeMSy III Failover Server: ¾¾Close all running applications. ¾¾Start the SeMSy_III_Installerx.x.x.exe application. The Select Language dialog is displayed. Fig. 4-1 ¾¾Select the required option. ¾¾Click OK. www.dallmeier.com 7

The welcome dialog is displayed. Fig. 4-2 ¾¾Click Next >. The End Users License Agreement dialog is displayed. Fig. 4-3 ¾¾Read and confirm the dialog with Agree >. www.dallmeier.com 8

The ReadMe dialog with information on system requirements and software versions of the applications to be installed is displayed. Fig. 4-4 ¾¾Read and confirm the dialog with Next >. The dialog for selecting the desired software package is displayed. Fig. 4-5 ¾¾Select the SeMSy III Failover Server entry from the drop down box. ¾¾Enable the Failover Server starting as a service? checkbox if required. If this checkbox is enabled the SeMSy III Failover Server is set up as a Windows service. It is started automatically during system startup and runs in the background. ¾¾Confirm the selection with Next >. www.dallmeier.com 9

The dialog for selecting the installation directory is displayed. The installation directory can not be changed. Fig. 4-6 ¾¾Confirm the dialog with Next >. The dialog in order to start the installation process is displayed. Fig. 4-7 ¾¾Click Next >. www.dallmeier.com 10

The dialog for entering the connection to the SeMSy III Setup Server is displayed. Fig. 4-8 ¾¾Enter in the Connection box the IP address of the SeMSy III Setup Server. ¾¾Confirm with OK. The installation process is started. Progress bars displays the procedure of the installation. Fig. 4-9 www.dallmeier.com 11

The dialog for completing the server installation and install other required components (MariaDB database, Network Time Protocol) is displayed. Fig. 4-10 ¾¾Click Finish >. The initial configuration of the SQL database management system (DBMS) MariaDB then runs automatically. Fig. 4-11 The dialog of the Network Time Protocol License Agreement is displayed. Fig. 4-12 ¾¾Read and confirm the dialog with I Agree. www.dallmeier.com 12

The dialog for selecting the NTP installation directory is displayed. Fig. 4-13 ¾¾Select via Browse... another directory for the NTP installation if required. ¾¾Confirm the selection with Next >. The dialog for selecting the NTP components to be installed is displayed. Fig. 4-14 ¾¾Disable components if required. ¾¾Confirm the selection with Next >. www.dallmeier.com 13

The NTP installation is running. Fig. 4-15 The dialog for selecting the NTP configuration settings is displayed. Fig. 4-16 ¾¾Enable the Create an initial configuration file with the following settings checkbox. ¾¾Make the required settings. ¾¾Click Next >. Fig. 4-17 ¾ ¾ Confirm the following information dialog in order to display the generated configuration file with Yes. www.dallmeier.com 14

The ntp.conf file is displayed in a text editor. Fig. 4-18 ¾¾Edit the line #server 127.127.1.0: ¾¾Remove the # comment character and enter the PC host name or the IP address of the SeMSy III Setup Server in order to use as a backup either the local system time or system time of SeMSy III Setup Server. ¾¾Save and close the ntp-conf file. The dialog for configuring the NTP service settings is displayed. Normally the already activated settings in the dialog can be used. Fig. 4-19 ¾¾Click Next > in order to create a NTP service account. www.dallmeier.com 15

The dialog for configuring the NTP service account is displayed. Fig. 4-20 ¾¾Enter a user name. ¾¾Enter a password and Confirm it. ¾¾Click Next >. The dialog for completion of the NTP installation is displayed. Fig. 4-21 ¾¾Confirm with Finish. It takes place the automatic installation of the required ActiveX *) component. Fig. 4-22 www.dallmeier.com 16

The system must be restarted in order to complete the installation of the SeMSy III Failover Server. Fig. 4-23 ¾¾Confirm the reboot with OK. The installation of the SeMSy III Failover Server was performed. The SeMSy III Failover Server starts automatically after rebooting the system if it was set up as a Windows service. A manual server start can be done via the executable FailoverMngr file in the C:\ Programs (x86) > Dallmeier > SeMSyIII > FailoverServer > FailoverManager directory. The SeMSy III Failover Server gets at the startup the configuration settings from the SeMSy III Setup Server, that has been specified at the installation. The additionally installed FailoverMngrClient application displays system-wide status information about the active failure recordings of a SeMSy III Failover Server (see below). The SysStart application allows to display status information about the operating state of a SeMSy III Failover Server and the required web service server if the SeMSy III Failover Server is not running as a Windows service in the background (see below). www.dallmeier.com 17

5 Status And Activity In order to display the status and activity of a SeMSy III Failover Server different applications are available. 5.1 Failover Manager Client The Failover Manager Client application provides an overview of status and activity of the connections taken over by a SeMSy III Failover Server, for example, by failure of recording equipment or loss of network connections. ¾¾Start the application with the FailoverMngrClient file in the C:\ Programs (x86) > Dallmeier > SeMSyIII > FailoverServer > FailoverManager directory. The view displays the failed Primary devices and which Spare devices have adopted the service: Fig. 5-1 5.1.1 SeMSy III Database The information about the connection of the SeMSy III database can be updated. ¾¾Select File > SeMSy Database in order to open the configuration dialog. Fig. 5-2 www.dallmeier.com 18

¾¾Make the required adjustments and changes to the database login and connection. ¾¾Confirm the input with OK. 5.1.2 Failover Server Database The information about the connection of the Failover Server database can be updated. ¾¾Select File > Failover Database in order to open the configuration dialog. Fig. 5-3 ¾¾Make the required adjustments and changes to the database login and connection. ¾¾Confirm the input with OK. 5.2 Web Service Server The RestFul WebService is part of the installation and provides status information of the encoders and cameras for a SeMSy III Failover Server. A software tool displays the current status of the web service. ¾¾Open the tool with the SeMSy3FailOverRFS file in the C:\ Programs (x86) > Dallmeier > FailoverServer > FailoverWebservice directory. Fig. 5-4 www.dallmeier.com 19

6 SysStart The SysStart application provides the automatic server startup and monitors the server operating, if the SeMSy III Failover Server was not set up as a Windows service. Even the startup and the status of the required RESTFul web service, which provides the encoder and camera information for the server, will be controlled by the SysStart. ¾¾Open the application with the SysStart file in the C:\ Programs (x86) > Dallmeier > SeMSy III > FailoverServer > SysStart directory or via the icon in the system tray. Fig. 6-1 ¾¾Check the display for the status of the server and web service. www.dallmeier.com 20