WAR NING S E C TION 1 : INTR ODUC TION HIG H V OLT AG E S C AN K ILL. 1.2.2 TC -V2 digital controller. 1.1 S afety P reca utions (WAR NING S )



Similar documents
AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

MTS Power Products MIAMI FL ATS-22AG. Automatic Transfer Switch And Control PLC Operator s Manual

ATC-300 Automatic Transfer Switch Controller

Controller Automation, Model II+

Instructions for Installation, Operation and Maintenance of the Eaton ATC-600 Automatic Transfer Switch Controller Instructional Booklet

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

GSM HOME SECURITY SYSTEM

FIREDEX Conventional Fire Panels

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

5500 Series, Catalog A5510 Thin Web Server software version 5

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Automatic Telephone Dialer TD-101(W)

Combi B Alarm box. Mounting instructions

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

ODYSSEY. Security System Owner s Manual. Kit No. 08E51-SHJ E55-SHJ American Honda Motor Co., Inc. - All Rights Reserved.

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

AUTODIALLER / QUICKDIALLER - SA132

Digital Keypad Use s Manual

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

GSM AUTO DIALER. Remote Monitoring & Control using your mobile phone.

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Transfer Equipment Controls

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

15 Series - Electronic step relay and dimmer. Features SERIE

Inwall 4 Input / 4 Output Module

HyperAccess Access Control System

Product Information Sheet UH28CS-12kV Hi Pot Tester

Zenith Controls ISO R-1000C 5/99

How to read this guide

GTEC transfer switch open transition

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

TS-770 SERIES CONFERENCE SYSTEM

1. INTRODUCTION FEATURES 2. PROGRAMMING

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y, 3x14/24 W and 4x14/24 W EXCEL T5

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

COMPALARM AP GENERAL MAIN FEATURES

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.

2 4PI175 issue 1_6/01. How to unset system in alarm. Programs 1, 2 and 3. Access codes. How to operate Personal Attack

How To Operate A Gec Transfer Switch Open Transition Amp Power Supply

Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives

9452/9453 Installation and User Guide

Inductive Proximity Sensors

Centro-Matic Automatic Lubrication Systems System Controls

Application Engineering

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

Automatic Transfer Switch Controller

Transponder reader CÉLIANE TECHNICAL GUIDE

T Sentry 4 Multi-Point Digital Alarm Instruction Manual

Auto Dialer. Manual E-921APQ E-921GPQ

Automatic AES Change-Over

A.1. a Division of Pittway Corporation. Documento: M MGAS-ENG. Edizione: 01/1997 Rev.:

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions

ELR: ABB range of front panel residual current relays Protection device according to IEC/EN Annex M

OPERATING INSTRUCTIONS SECURITY SYSTEM KIT NO.: 08E51-EP American Honda Motor Co., Inc. - All Rights Reserved. 1

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, W EXCEL T5

computer radio control system

I.L T.K. Instructions for Cutler-Hammer MP1 Series Automatic Transfer Switches A

Thyristor-controlled power supplies and battery chargers

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

OWNERS MANUAL. Status Monitor. for Windows 95, 98, ME, NT 4, 2000 & XP. SIGNALCRAFTERS TECH, INC.

MANUAL FOR MODEL MP30 ELECTRIC MOTOR DRIVEN LIMITED SERVICE CONTROLLER

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Section D..General Auto Electrical Corporation

Automatic start of a generator

Programming A PLC. Standard Instructions

FL ballasts Electronic dimming. PCA T5 ECO lp Y II, W ECO T5

Operational Overview and Controls Guide

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

Series Six Plus Programmable Controller

SECTION DETECTION AND ALARM

HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Safety automation solutions

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S


Car Alarm Series 2 B 2 Buttons

NDQ5 Series. Automatic Transfer Switch. Shanghai Liangxin Electrical CO.,LTD

DC-8706K Auto Dial Alarm System

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

3PH2 or 3PHE 3 Phase Control Board

GST301. (Single Protection Zone) Operation Manual

Single Phase Magnetic Card Electricity Meter

NC-12 Modbus Application

Fire Alarm Control Panel. Family. Operating Manual

Inwall Room Temperature Unit

650W Single Output Power Supply

Energy Division

How To Set Off An Alarm On A Car With A Car Alarm On It

Transcription:

S E C TION 1 : INTR ODUC TION 1.1 S afety P reca utions (WAR NING S ) T his manual covers the ins tallation, operation and maintena nce of the T C S 3P 125 Automatic T rans fer S witch. It is intended for qualified pers onal only. WAR NING HIG H V OLT AG E S C AN K ILL. 1.2 P roduc ts Overview T he T C S 3P 125 automatic trans fer s witch cons is t of two parts the T S 3P 125 s witch and the T C -V 2 electronic control unit: 1.2.1 TS 125 Features T he contacts on the T S 3P 125 trans fer s witch are clas s P C, this mea ns that it is capable of making and withs tanding s hort circuits but is not intended for breaking s hort circuit current. R ated operating V oltage:600v AC. R ated operating C urrent:125amps Number of poles:3p C oil operating voltage:220v AC ±20% S mall size, light weight and low power consumption. E lectrically operated and mechanically held. Manufactured us ing UL 94V -0 plas tics. Adjus table time delay in OF F pos ition when trans ferring. Des igned for cell-phone repeaters, and many indus trial and home AT S applications. 1.2.2 TC -V2 digital controller T he T C -V 2 digital control unit offers programming flexibility to cus tomize the AT S to different cus tomer requirements. The controller : Monitor normal s ource for full phas e over and under voltages. Monitor emergency s ource for s ingle phas e over and under voltages. Normal & emergency s ource voltage and freque ncy parameter dis play. T DE N, T DN E, T DE C and T DOF F real time countdown dis play. P ermit tes ting the trans fer s witch from the control panel. P ermit tes ting the trans fer s witch with / without load from the front panel. B uilt-in 1 to 4 weeks exercis er timer. P ermit cus tomer plant exercis er tes t with / without load on a pres et period. S tore cus tomer / factory es tablis hed parameters in permane nt memory. S hows s tatus and fail alarm LE D s on the front panel. No need for a P C connection and programming s oftware. Any and all changes can be made in the field. Des ign for ins tallation next to s witch or on the front panel. TS3P125 TC-V2 1

SECTION 2 : HARDWARE DESCRIPTION 2.1 Front Panel Load Connector Load Display Window Function Slector Manual Handle ATS Status Emergency Normal 2

2.2 T C S3P1 25 Dimens ions (Unit : mm) 2.3 P ane l C ut-out for the TC -V2 (Unit : mm) 3

SECTION 3 : FUNCTION DESCRIPTION 3.1 General Operation of the TCS3P125 electronic control. 3.2 TDNE Settings TDNE provides a time delay when transferring from Normal to Emergency. Timing begins when the Emergency Source (generator) becomes available. TDNE:Adjustable from 0 t o 99 seconds. 3.3 TDEN Settings TDEN provides a time delay when transferring from Emergency to Normal. This permits stabilization of the Normal Power before transferring back to normal. Timing begins when the Normal Power returns and becomes available and steady. TDNE:Adjustable from 0 t o 99 seconds. 3.4 TDEC Settings TDEC timer keeps the generator running without load (Engine Cool-down) after the ATS transfer back to Normal Power. Timing begins when the transfer back t o normal is completed. TDEC:Engine Cool-down - from 0 to 99 sec. 3.5 TDES Setting TDES is the time delay for Engine Start when the Normal Source voltage is in over or under-voltage (OV or UV). If power return to normal while timing, the TDES timer resets and starts again. TDEC:Adjustable from 0 t o 30 seconds. 3.6 TD-OFF Setting Time Delay on OFF this timer keeps the switch in the center neutral OFF position (completely disengaged) before transferring to the other side. You can preset the switch in Neutral or OFF from 0 to 18 seconds (2 to 3 sec in normal). TD-OFF:Adjustable from 1 t o 20 seconds. 3.7 Plant Exerciser This feature provides for automatic test operation of the generator. The interval is fixed at once per 1 to 4 weeks with a specific test day and time. The exerciser can be set for either testing with load or without load. When the exerciser is activated the exerciser LED (EX)on the right side of display flashes and turns on during the exercise period. 3.8 Over / Under Voltage Sensing The TC-V2 constantly monitors normal & emergency power. When power falls outside the programmed voltages this LED turns RED and flashes to show OV /UV problems. Adjustable Over voltage range:110vac ~ 530VAC Over voltage reset:when voltage falls below 10VAC of the OV setting Adjustable Under voltage range:80vac ~ 470VAC Under voltage reset:when voltage exceeds 10VAC of the UV setting 3.9 Transfer Failure When a transfer is made the TS125 communicates it s position to the TC-V2 controller by using two small internal micro-switches, if this signal is not received, it will try switching 3 more times every 2 seconds or until the connection is made. A flashing light indicator and a FAIL signal displayed an incomplete transfer and that the ATS mechanism or wiring is defective. If the ATS fails, the TC-V2 controller stops all ATS functions and starts flashing until the failure is corrected and the control is reset. To reset the t ransfer fail alarm: 1. Manually move t he ATS t o the correct position. 2. Press any buttons (Auto Program or Test) on the front panel to reset the alarm. 4

SECTION 4 : OPERATION 4.1 General This section specifically describes the operation and functional use of the TC-V2 controller. 4.2 Auto Mode In AUTO the TC-V2 controller automatically transfer and retransfers from source to source as directed by the pre-programmed instructions. In AUTO the controller, monitor the condition of both normal and standby power sources providing the logic for the transfer operation. 4.3 Test Mode The TC-V2 is provided with a test pushbutton that simulates the loss of normal source. Pushing the Test key the TC-V2 runs a test on the ATS. The TDES and TDNE programmed time delays will be performed as part of the test. There are two test modes: Testing with load Testing without load 4.4 Programming Mode The TC-V2 controller is fully programmable from the front panel when in Program Mode. The build-in program buttons have multiple functions: Real t ime clock displaying Programming mode operating To enter programming mode, push & hold the PEN Program button for 10 seconds. In the first 10 seconds the screen showing internal real time clock and then the word Vr 1.0 appears on the front display window for 2 seconds indicating the version of the software. At this time start a line by line programming sequence. To advance to the next line, push the Program button on the front panel. To change each line s programming parameters, press the increase ( ) and decrease ( ) buttons. When pressing and releasing the ( ) or ( ) key the displayed parameter can be increased or decreased by one. The parameter will continue to scroll if the ( ) or ( ) button is pressed and not released. Always push the Program button to advance to the next line or until the word End appears on the screen. To immediately end the programming mode, you simply push the Program button for 4 seconds. Then the word End shows on the screen indicating the end of the programming mode. If you like to return to factory settings, stay in programming mode and simultaneously press all 3 buttons ( ), ( ) and Program buttons for 4 seconds. The TC-V2 will now automatically program itself to factory settings and the word Au.Po will appear on the display window. 4.5 Specification Summary PARAMETER Rated Voltage Rated Current Rated Frequency Poles Switch Type ATS Class Operation Life Transfer Current Remote Start contactor N & E On contactor SPECIFICATION 600 VAC 125 Amp 50/60 Hz 3P Power Consumption <1W Operating Temperature Storage Temperature Double Throw Class PC Over 6000 Times W/L 2.0A @ 220VAC 6A @ 277VAC Max 7A @ 250VAC Max -10? C ~ 70? C -20? C ~ 80? C Operating Humidity 0 to 95% Weight 1.8kg ±2% 5

4.6 System Setting Reference Table ITEM DESCRIPTION SETTING FACTORY SETTING 1 Is this ATS operator in 1Ø or 3Ø 01) 1Ø 02) 3Ø 02 2 TDNE Time delay normal to emergency 00 ~ 99 sec 10sec 3 TDEN Time delay emergency to normal 00 ~ 99 sec 10sec 4 TDES Time delay engine start 00 ~ 30 sec 5sec 5 TDEC Time delay engine cool-down 00 ~ 99 sec 60sec 6 TD-OFF Time delay on OFF position 01 ~ 20 sec 5sec 7 Normal source over voltage setting 11 ~ 53 ( 110V ~530V ) 25 (250V) 8 Normal source under voltage setting 08 ~ 47 ( 80V ~ 470V ) 18 (180V) 9 Time delay if there is a problem with normal source voltage output 0 ~ 99sec ( 0 = Without volt monitor function ) 10sec 10 Standby source over voltage setting 11 ~ 53( 110V ~530V ) 25 (250V) 11 Standby source under voltage setting 08 ~ 47 ( 80V ~ 470V ) 18 (180V) 12 Time delay if there is a problem with standby source voltage output 0 ~ 99sec ( 0 = Without volt monitor function ) 10 13 Current day of week setting 01 ~ 07 (Monday to Sunday) current 14 Current hour setting 00 ~ 23 current 15 Current minute setting 00 ~ 59 current 16 Plant exerciser test day of week 01 ~ 07 (Monday to Sunday) 06 17 Plant exerciser hour 00 ~ 23 12 18 Engine run time on exerciser 0 ~ 60 min ( 0 = Without exerciser function ) 00 19 Exerciser cycle 01) Once a Week 02) Once every 2 weeks 03) Once every 3 Weeks 04) Once every 4 weeks 20 Plant exerciser test with or without load 01) Without load 02) With load 01 21 Plant Manual test with or without load 01) Without load 02) With load 02 01 6

SECTION 5 : INSTALLATION INSTRUCTIONS 5.1 General The TC-V2 controller is modular and is designed for installation next to switch or on the front door panel. A longer harness is required for door installation. 5.2 Installation On The Plate STEP-1 STEP-2 STEP-3 STEP-4 7

5.3 Ins tallation On The Door P ane l S T E P -1 S T E P -2 S T E P -3 S T E P -4 S T E P -5 S T E P -6 8

S E C T IO N 6 : T Y P IC AL WIR ING 6.1 TCS 3P 125 S tanda rd Wiring Diag ram (220 V ) #NLS>>Normal Auxiliary S witch #ELS>>Emergency Auxiliary Switch L OA D L 1 L 2 L 3 T S 3P 125 NOR MAL S OUR C E N1 N2 N3 C S 1 C S 1 C S 1 C S 2 C S 2 C S 2 E 1 E ME R G E NC Y E 2 S OURC E E 3 NL S E L S 220V C OIL CN 1 C onnector CN 1-1 BR O WN CN 1-5 G R E E N CN 1-9 WHITE CN 1-10 B L AC K CN 1-6 B L UE CN 1-11 P INK CN 1-2 R E D CN 1-3 OR AN G E CN 1-4 YE LL OW CN 1-8 CN 1-12 R E D/WHITE CN 2-12 CN 2-4 CN 2-3 CN 2-2 CN 2-11 CN 2-6 CN 2-10 CN 2-9 CN 2-5 CN 2-1 CN 2 C onnector T C -V 2 C on troller R emote S tart 9

6.2 TCS 3P 125 S tanda rd Wiring Diag ram (380 / 440 / 480V) #NLS >>Normal Auxiliary S witch #E LS >>Emergency Auxiliary Switch L OAD L 1 L 2 L 3 T S 3P 125 NOR MA L S OURC E C S 1 N1 N2 E 1 E ME R G E NC Y C S 1 C S 2 E 2 S OUR C E N3 C S 1 C S 2 E 3 C S 2 NL S E L S 220V C OIL CN 1 C onn ec tor CN 1-1 BR OWN CN 1-5 G R EE N CN 1-9 WHIT E CN 1-10 B L AC K CN 1-6 B L UE CN 1-11 P INK CN 1-2 R E D CN 1-3 ORAN GE CN 1-4 YE LL OW CN 1-8 CN 1-12 R E D/WHIT E T S P -XX CN 2-12 CN 2-4 CN 2-3 CN 2-2 CN 2-11 CN 2-6 CN 2-10 CN 2-9 CN 2-5 CN 2-1 CN 2 C onn ec tor T C -V 2 C ontroller R emote S tart T S P -XX Mode N O. T S P -38 T S P -44 T S P -48 S ys tem Volt 380 VAC 440 VAC 480 VAC 10