Start-up Guide. InterBus-S Adapter Module NIBA-01
|
|
|
- Antonia Stanley
- 10 years ago
- Views:
Transcription
1 ABB Drives Installation and Start-up Guide InterBus-S Adapter Module NIBA-01
2
3 InterBus-S Adapter Module NIBA-01 Installation and Start-up Guide 3AFY REV B EFFECTIVE: ABB Oy. All Rights Reserved.
4 ii NIBA-01 Installation and Start-up Guide
5 Safety Instructions Overview Warnings and Notes Warnings This chapter states the safety instructions that must be followed when installing and operating the NIBA-01 InterBus-S Adapter Module. The material in this chapter must be studied before attempting any work on, or with, the unit. This manual distinguishes two sorts of safety instructions. Warnings are used to inform of conditions which can, if proper steps are not taken, lead to a serious fault condition, physical injury and death. Notes are used when the reader is required to pay special attention or when there is additional information available on the subject. Notes are less crucial than Warnings, but should not be disregarded. Readers are informed of situations that can result in serious physical injury and/or serious damage to equipment with the following symbols: Dangerous Voltage Warning: warns of situations in which a high voltage can cause physical injury and/or damage equipment. The text next to this symbol describes ways to avoid the danger. General Warning: warns of situations which can cause physical injury and/or damage equipment by means other than electrical. The text next to this symbol describes ways to avoid the danger. Electrostatic Discharge Warning: warns of situations in which an electrostatic discharge can damage equipment. The text next to this symbol describes ways to avoid the danger. Notes Readers are notified of the need for special attention or additional information available on the subject with the following symbols: CAUTION! Note: Caution aims to draw special attention to a particular issue. Note gives additional information or points out more information available on the subject. NIBA-01 Installation and Start-up Guide iii
6 Safety Instructions General Safety Instructions WARNING! All electrical installation and maintenance work on the drive should be carried out by qualified electricians. The drive and adjoining equipment must be properly earthed. Do not attempt any work on a powered drive. After switching off the mains, always allow the intermediate circuit capacitors 5 minutes to discharge before working on the frequency converter, the motor or the motor cable. It is good practice to check (with a voltage indicating instrument) that the drive is in fact discharged before beginning work. The motor cable terminals of the drive are at a dangerously high voltage when mains power is applied, regardless of motor operation. There can be dangerous voltages inside the drive from external control circuits even when the drive mains power is shut off. Exercise appropriate care when working with the unit. Neglecting these instructions can cause physical injury and death. WARNING! There are several automatic reset functions in the drive. If selected, they reset the unit and resume operation after a fault. These functions should not be selected if other equipment is not compatible with this kind of operation, or dangerous situations can be caused by such action. More Warnings and Notes are printed at appropriate instances along the text. iv NIBA-01 Installation and Start-up Guide
7 Table of Contents Safety Instructions Overview iii Warnings and Notes iii Warnings iii Notes iii General Safety Instructions iv Table of Contents Chapter 1 Introduction to This Guide Overview Intended Audience What This Guide Contains Conventions Used in This Guide Chapter 2 Overview Overview The InterBus-S System Topology Data Channels The NIBA-01 InterBus-S Adapter Module Status LEDs Compatibility Delivery Check Warranty and Liability Information Chapter 3 Mechanical Installation Overview Mounting Outside the Drive Mounting Inside the Drive Chapter 4 Electrical Installation Overview Cabling Module Earthing Bus Cable Connections NIBA-01 Installation and Start-up Guide v
8 Table of Contents Chapter 5 Programming Overview Drive Configuration Control Locations Host Configuration Calculating the Optimal Cycle (Scan) Time Chapter 6 Communication Overview InterBus-S Message Frame PCP Services Supported by NIBA The Control Word and the Status Word References Actual Values Appendix A Definitions and Abbreviations Appendix B Technical Data DDCS Link B-1 InterBus-S B-2 NIBA B-3 Appendix C Ambient Conditions Ambient Conditions, Operation C-1 Ambient Conditions, Storage C-1 Ambient Conditions, Transportation C-1 vi NIBA-01 Installation and Start-up Guide
9 Chapter 1 Introduction to This Guide Overview Intended Audience What This Guide Contains This chapter contains a description of the Installation and Start-up Guide for the NIBA-01 InterBus-S Adapter Module. The Guide is intended for the people who are responsible for installing, commissioning, and using the NIBA-01 InterBus-S Adapter Module with an ABB drive. The reader is expected to have a basic knowledge of electrical fundamentals and wiring practices the drive and its control panel the host controller software. The installation and start-up of the NIBA-01 InterBus-S Adapter Module are introduced in this Guide. It is assumed that the drive is installed and ready to operate before starting the installation of the adapter module. For more information on the installation and start-up procedures of the drive, please refer to its user documentation. Safety Instructions are featured in the first few pages of this Guide. Safety Instructions describe the formats for various warnings and notations used within this Guide. This chapter also states the safety instructions which apply to the installation and operation of the NIBA-01 Module. Chapter 1 Introduction to This Guide contains a short description of the Guide. Chapter 2 Overview contains a short description of the InterBus-S system and the NIBA-01 InterBus-S Adapter Module, a delivery checklist, and information on the manufacturer s warranty. Chapter 3 Mechanical Installation contains the placing and mounting instructions for the module. Chapter 4 Electrical Installation contains the wiring instructions. Chapter 5 Programming explains how to program the drive before the communication through the adapter module can be started. Chapter 6 Communication contains a description of how data is transmitted through the NIBA-01. Appendix A explains definitions and abbreviations concerning the InterBus-S system. Appendix B contains Technical Data. NIBA-01 Installation and Start-up Guide 1-1
10 Chapter 1 Introduction to This Guide Appendix C contains a specification of the ambient conditions allowed during transportation, storage and use of the NIBA-01. Conventions Used in This Guide Communication Module (COMM.MODULE) Data Sets and Data Words Host NIBA-01 InterBus-S Adapter Module Parameter Communication Module is a parameter name/parameter selection name for a device (e.g. a fieldbus adapter) through which the drive is connected to an external serial communication network (e.g. a fieldbus). The communication with the communication module is activated with a drive parameter. Data sets are clusters of data sent through the DDCS link between the fieldbus adapter module and the drive. Each data set consists of three 16-bit words, ie. data words. The Control Word (sometimes called the Command Word) and the Status Word, References and Actual Values (see Chapter 6) are types of data words; the contents of some data words are user-definable. Refers to the InterBus-S master station, i.e. a PLC or a computer controlling the bus through an InterBus-S interface. The NIBA-01 Adapter Module is one of the optional fieldbus adapter modules available for ABB drives. The NIBA-01 is a device through which an ABB drive is connected to an InterBus-S serial communication bus system. A parameter is an operating instruction for the drive. Parameters can be read and programmed with the drive control panel, or through the NIBA-01 Module. 1-2 NIBA-01 Installation and Start-up Guide
11 Chapter 2 Overview Overview The InterBus-S System Topology This chapter contains a short description of the InterBus-S system and the NIBA-01 Adapter Module, a delivery checklist, and warranty information. InterBus-S is an open serial communication standard for the sensor actuator level. The protocol is based on DIN Part 2 and itself specified in DIN In the exchange of parameter data, InterBus-S employs the FMS user interface. Further information is available from the host controller documentation, Phoenix Contact ( and the INTERBUS Club ( The physical transmission medium of InterBus-S is a twisted pair cable (according to the RS 485 standard). The main bus in InterBus terminology, the remote bus may contain 32 segments, each consisting of a cable and the device connected to it. The maximum length of one segment is 400 m. Local branches (referred to as installation remote buses and local buses, depending on branch type) can be connected to the remote bus using so-called bus terminals. Host Remote Bus ABB Drive Local Bus NIBA-01 Remote Bus Segments Bus Terminal Installation Remote Bus Terminal I/O I/O I/O I/O I/O Bus Terminal Installation Remote Bus NIBA-01 Installation and Start-up Guide 2-1
12 Chapter 2 Overview Data Channels The InterBus-S system provides two channels for data transfer, the process data channel (for fast cyclic transfer of time-critical I/O data) and the PCP channel (for acyclic transfer of non-time-critical, complex blocks of data, e.g. parameter data). The NIBA-01 InterBus-S Adapter Module The NIBA-01 InterBus-S Adapter Module is an optional device that enables connection of an ABB drive to an InterBus-S system. The module is considered a remote bus device by the host. Through the NIBA-01 InterBus-S Adapter Module it is possible to: Give control commands to the drive (Start, Stop, Run enable, etc.) Feed a motor speed or torque reference to the drive Give a process actual value or a process reference to the PID controller of the drive Read status information and actual values from the drive Change drive parameter values Reset a drive fault. The InterBus-S commands and services supported by the NIBA-01 are discussed in Chapter 6. Please refer to the user documentation of the drive as to which commands are supported by the drive. The adapter module is mounted onto a standard mounting rail inside or outside the drive unit, depending on drive type and configuration. See the user s manual of the drive for module placement options. Screw terminal block for the bus cable OUT connection (see Chapter 4) RB5V RBST DG2 /DO2 DO2 /DI2 DI2 SH X2 RXD OUT TR Fibre optic connectors for connection to the drive: RXD = Receiver TXD = Transmitter RD TXD IN X1 DDCS IB-S ERROR U L RC BA INTERBUS-S ADAPTER NIBA-01 0V +24V DG1 /DI1 DI1 /DO1 DO1 SHF Status LEDs (For descriptions see next page) Screw terminal block for the bus cable IN and power supply connections (see Chapter 4) 2-2 NIBA-01 Installation and Start-up Guide
13 Chapter 2 Overview Status LEDs There are eight status LEDs on the NIBA-01 Module. The table below explains their functions. LED Operation Explanation DDCS flashing DDCS initialisation in progress flashing, ERROR lit lit DDCS communication errors DDCS communication established IB-S flashing (fast) Waiting for InterBus-S communication flashing (slowly) flashing together with ERROR flashing, ERROR lit lit I/O mode (process data communication enabled only) ROM checksum test failed InterBus-S communication error(s) PCP mode (process data and PCP communication enabled) ERROR lit PCP initialisation error lit, DDCS flashing lit, IB-S flashing flashing flashing together with IB-S DDCS communication errors InterBus-S communication error(s) RAM test failed ROM checksum test failed RC (Remote Bus Check) lit Cable connection correct, host not being reset BA (Bus Active) lit Bus is active TR (Transmit/Receive) flashing PCP communication active U L lit Module power OK (reset inactive) RD (Remote Bus Disabled) lit Extended remote bus interface disabled Compatibility The NIBA-01 is compatible with: ACS 600 SingleDrive (SW vsn ACxA5000 or later) ACS 600 MultiDrive (SW vsn AMxM103a or later) ACS 600 MotionControl (ACP 600) (SW vsn APxA1100 or later) ACS 600 Pump & Fan Drive (ACF 600) (SW vsn AF0A1020 or later) DCS 500 (SW vsn DC21x226 or later) All host stations equipped with an InterBus-S interface. NIBA-01 Installation and Start-up Guide 2-3
14 Chapter 2 Overview Delivery Check Warranty and Liability Information The NIBA-01 package contains: InterBus-S Adapter Module, Type NIBA-01 Two pairs (four pieces) of fibre optic cables for connecting the adapter to the drive Mounting rail This manual, the NIBA-01 Installation and Start-up Guide. The warranty for your ABB drive and options covers manufacturing defects. The manufacturer carries no responsibility for damage due to transport or unpacking. In no event and under no circumstances shall the manufacturer be liable for damages and failures due to misuse, abuse, improper installation, or abnormal conditions of temperature, dust, or corrosives, or failures due to operation above rated capacities. Nor shall the manufacturer ever be liable for consequential and incidental damages. The period of manufacturer's warranty is 12 months, and not more than 18 months, from the date of delivery. Extended warranty may be available with certified start-up. Contact your local distributor for details. Your local ABB Drives company or distributor may have a different warranty period, which is specified in their sales terms, conditions, and warranty terms. If you have any questions concerning your ABB drive, contact your local distributor or ABB Drives office. The technical data and specifications are valid at the time of printing. ABB reserves the right to subsequent alterations. 2-4 NIBA-01 Installation and Start-up Guide
15 Chapter 3 Mechanical Installation Overview Mounting Outside the Drive This chapter contains module mounting instructions. Depending on the drive, the module can be installed either inside or outside the drive housing or cabinet. See the user s manual of the drive for module placement options. Choose the location for the module. Note the following: The cabling instructions must be followed (see Chapter 4). Also, the length of the fibre optic cables included in the option package restrict the distance between the module and the drive. Observe the free space requirements for the module (min. 10 mm from adjoining equipment or wall) and the drive (see the drive documentation). The ambient conditions should be taken into account (see Appendix C). The degree of protection of the module is IP 20. Module earth is connected to the mounting rail by means of an earthing clip (see Figure 3-1 below). The mounting rail onto which the option module is to be mounted must be earthed to a noiseless earth. If the rail is not mounted on a properly earthed base, a separate earthing conductor must be used. The conductor must be as short as possible and the cross-sectional area must be 6 mm 2 at least. Note: No solid copper conductor may be used (stranded wire allowed only). Mounting instructions: 1. Switch off all dangerous voltages in the enclosure that the module is to be mounted in. 2. Fasten the rail and ensure the proper earthing as described above. 3. Push the module onto the rail. The module can be released by pulling the locking spring with a screwdriver (see Figure 3-1). Earthing Clips Figure 3-1 Mounting and removing the module. NIBA-01 Installation and Start-up Guide 3-1
16 Chapter 3 Mechanical Installation Mounting Inside the Drive The work inside the drive should be carried out by a qualified electrician only. WARNING! Pay attention to the slowly discharging voltage of the capacitor bank and the voltages that are connected from external control circuits to the inputs and outputs of the drive. WARNING! Do not touch the printed circuit boards. The integrated circuits are extremely sensitive to electrostatic discharge. Mounting instructions: 1. Stop the drive. 2. Switch off the power supply of the drive and all dangerous voltages connected to the inputs and outputs. 3. Wait for five minutes to ensure that the capacitors in the intermediate circuit have discharged. 4. Remove the front cover of the drive. 5. Ensure that the mains cable, motor cable and capacitor bank (UDC+ and UDC ) are not powered. 6. Locate the position for the module (see the user s manual of the drive). Fasten the mounting rail to its place if not already installed. Observe the free space requirements for the module (min. 10 mm from adjoining equipment/wall). 7. Push the module onto the rail. The module can be released by pulling the locking spring with a screwdriver (see Figure 3-1). 3-2 NIBA-01 Installation and Start-up Guide
17 Chapter 4 Electrical Installation Overview This chapter contains: Cabling instructions Connection and earthing instructions for the NIBA-01 Module and earthing instructions for the bus cable. WARNING! Before installation, switch off the drive power supply. Wait for five minutes to ensure that the capacitor bank of the drive is discharged. Switch off all dangerous voltages connected from external control circuits to the inputs and outputs of the drive. Cabling Arrange the bus cables as far away from the motor cables as possible. Avoid parallel runs. Use bushings at cable entries. Handle the fibre optic cables with care. When unplugging optic cables, always grab the connector, not the cable itself. Do not touch the ends of the fibres with bare hands as the fibre is extremely sensitive to dirt. The maximum long term tensile load for the fibre optic cable is 1 N. The minimum short term bend radius is 25 mm. The NIBA-01 module is connected to the drive using a fibre optic cable link. Consult the drive documentation as to the corresponding terminals inside the drive. X2: ABB Drive RB5V X2 OUT RBST RXD DG2 /DO2 DO2 /DI2 DI2 SH TR RD IN X1 TXD DDCS IB-S ERROR U L RC BA INTERBUS-S ADAPTER NIBA-01 0V +24V DG1 /DI1 DI1 /DO1 DO1 SHF DDCS T R X1: Figure 4-1 Fibre optic link between the NIBA-01 adapter and the drive. NIBA-01 Installation and Start-up Guide 4-1
18 Chapter 4 Electrical Installation Module Earthing Bus Cable Connections The NIBA-01 module earth is connected to the rail onto which the module is mounted. If the rail is fastened to an earthed metallic assembly plate, the module is automatically earthed, and no external earthing wire is needed. If the rail is fastened to a base that is not earthed, the rail must be connected to the nearest earthing terminal. However, the earthing wire should not be connected to the same terminal as the power cable screens. (See page 3-1.) The incoming bus cable and the external power supply are connected to terminal block X1 on the NIBA-01. The outgoing bus cable (if required) is connected to X2. See the connection diagram on page 4-4. Note: If the NIBA-01 module is the last station on the remote bus, the terminals of X2 are left unconnected. Bus Cable Specifications Ready-made remote bus cables in different lengths are available from Phoenix Contact. If these are not used, the cable should fulfil the following specifications: Parameter Value Test Method No. of Conductors 3 x 2 (twisted pairs), common shield Conductor Cross-section Min. 0.2 mm 2 Conductor Resistance (DC) Max. 9.6 Ω/m VDE , IEC cl. 5-1 Characteristic Impedance 120 Ω ± 20% at f = MHz, 100 Ω ± 15% at f > 1 MHz IEC cl Dielectric Strength, Conductor/Conductor, Conductor/Shield 1000 V RMS, 1 min VDE Test type C or IEC cl. 5.2 Insulation Resistance (after Dielectric Strength test) Min. 150 MΩ/1000 metres of cable VDE Test type B or IEC cl. 5.3 Maximum Transfer Impedance at 30 MHz 250 mω/m IEC 96-1 Operating Capacity at 800 Hz Max. 60 nf/1000 metres of cable VDE Test type A, IEC cl. 5-4 Minimum Near-end Crosstalk Attenuation (NEXT) for 100 metres of cable at VDE or IEC cl MHz 1 MHz 2 MHz 4 MHz 8 MHz 10 MHz 16 MHz 20 MHz 61 db 59 db 55 db 50 db 46 db 44 db 41 db 40 db 4-2 NIBA-01 Installation and Start-up Guide
19 Chapter 4 Electrical Installation Terminal Blocks Table 4-1 Description of terminal block X1 (INPUT). X1 (IN) 1 0V 2 +24V Description Power supply for the module 24 V d.c. ± 10 %; maximum power consumption 160 ma 3 DG1 Signal Ground 4 /DI1 Data in 1 (Inverted) 5 DI1 Data in 1 6 /DO1 Data out 1 (Inverted) 7 DO1 Data out 1 8 SHF Filtered Shield (Connected to module earth via an RC filter) Table 4-2 Description of terminal block X2 (OUTPUT). (Not connected if the module is the last device on the remote bus.) X2 (OUT) Description 1 SH Shield (Module earth) 2 DI2 Data in 2 3 /DI2 Data in 2 (Inverted) 4 DO2 Data out 2 5 /DO2 Data out 2 (Inverted) 6 DG2 Signal Ground 7 RBST Remote Bus Connector 8 RB5V Signal +5V NIBA-01 Installation and Start-up Guide 4-3
20 Chapter 4 Electrical Installation Connection to Remote Bus Serial Connection of Modules Female DSUB Connector Housing 9 6 DG DO DO DI DI REMOTE BUS OUT (Not connected if the module is the last device on the remote bus) DG DO DO DI DI RB5V X2 OUT IN X1 RBST RXD TXD DDCS IB-S ERROR DG2 /DO2 DO2 /DI2 DI2 SH TR RD U L RC BA INTERBUS-S ADAPTER NIBA-01 0V +24V DG1 /DI1 DI1 /DO1 DO1 SHF RB5V X2 OUT RBST RXD DG2 /DO2 DO2 /DI2 DI2 SH TR 0V +24V IN X1 TXD DDCS IB-S ERROR RD U L RC BA INTERBUS-S ADAPTER NIBA-01 0V +24V DG1 /DI1 DI1 /DO1 DO1 SHF 0V +24V DG DI DI DO DO RB5V X2 OUT RBST RXD DG2 /DO2 DO2 /DI2 DI2 SH TR RD TXD REMOTE BUS IN IN X1 DDCS IB-S ERROR U L RC BA INTERBUS-S ADAPTER NIBA-01 0V +24V DG1 /DI1 DI1 /DO1 DO1 SHF Male DSUB Connector DG DI DI DO DO Housing 5 9 Figure 4-2 InterBus-S remote bus cable connections. 4-4 NIBA-01 Installation and Start-up Guide
21 Chapter 5 Programming Overview Drive Configuration This chapter gives information on configuring the drive and the InterBus-S system for communication through the NIBA-01 Module. It is assumed that the NIBA-01 has been mechanically and electrically installed according to the instructions given in Chapters 3 and 4. The detailed procedure of activating the module for communication with the drive is dependent on drive type. (Normally, a drive parameter must be adjusted to activate the communication. See the drive documentation.) As communication between the drive and the NIBA-01 is established, the configuration parameters of the module become available at the drive. These parameters shown below in Table 5-1 must be checked first and adjusted if necessary. The alternative selections for these parameters are discussed in more detail below the table. (Note that the new settings take effect only when the module is powered up for the next time.) Note: The groupings, numberings, and adjustment procedures of parameters vary. Refer to the drive documentation. Table 5-1 NIBA-01 configuration parameters. Fieldbus Par. No. Name Alternative Settings Default Setting Note 1 MODULE TYPE NIBA-01 Vx.x Not adjustable 2 COMM. MODE PCP; I/O; I/O MUXED PCP 3 IB TIME-OUT 0 to ~ 1 s (0 = disabled) 4 DATA SET OFFSET FBA D SET 1; FBA D SET 10 FBA D SET 1 MODULE TYPE This parameter shows the module type as detected by the drive. The value cannot be adjusted by the user. (If this parameter is undefined, the communication between the drive and the module has not been established.) NIBA-01 Installation and Start-up Guide 5-1
22 Chapter 5 Programming COMM. MODE This parameter selects the operating mode of the NIBA-01. The NIBA-01 InterBus-S Adapter Module has three operating modes. PCP Process data channel and PCP channel enabled. This setting should be selected if drive parameters are to be adjusted through the fieldbus. I/O Process data channel enabled only. This setting is ideal for applications that do not require drive parameter adjustment through the fieldbus. Furthermore, equipment set-up is also simple, requiring only the definition of addressing areas by means of the controller program. I/O MUXED Process data channel enabled only. The first word of InterBus process data is used to indicate a multiplexed data word. The first IN data word selects the word to be read; the first OUT data word indicates the data word which was read. The index value range is 0 to 9. If the index value is greater than 9, the module will sequentially cycle through the indexes 0 to 9, incrementing the index with each InterBus message. Index Name Information Note 0 Actual Value 2 *Data Set 2 Word 3 1 Actual Value 3 *Data Set 4 Word 1 2 Actual Value 4 *Data Set 4 Word 2 3 Actual Value 5 *Data Set 4 Word 3 4 Actual Value 6 *Data Set 6 Word 1 5 Actual Value 7 *Data Set 6 Word 2 6 Actual Value 8 *Data Set 6 Word 3 7 Actual Value 9 *Data Set 8 Word 1 Actual Value support depends on drive type and application program. See the Firmware Manual of the drive for more information. 8 Actual Value 10 *Data Set 8 Word 2 9 Actual Value 11 *Data Set 8 Word 3 >9 Cycle indexes 0 to 9. The OUT index value indicates the value which was read. *Add 9 to data set number if module configuration parameter 4 (DATA SET OFFSET) is set to FBA D SET 10. Direction Process Data Word 1 Process Data Word 2 Process Data Word 3 Process Data Word 4 IN Index of data word to be read Control Word Reference 1 Reference 2 OUT Index of data word which was read Status Word Actual Value 1 (One of the values in table above) 5-2 NIBA-01 Installation and Start-up Guide
23 Chapter 5 Programming IB TIME-OUT DATA SET OFFSET Control Locations If the communication between the NIBA-01 and the host fails, this parameter defines the time after which the NIBA-01 stops communicating with the drive. (See the drive manuals for information on drive behaviour if this occurs.) Setting the parameter to 0 disables the function. Otherwise, 1 unit corresponds to approx. 0.1 seconds. Selects the number of the first data set to be used for fieldbus communication. By default, the value of this parameter is FBA D SET 1, denoting that data sets from no. 1 onwards are used for communication with the drive. However, some drives reserve these data sets for other use, so it may be necessary to use other data sets. Setting this parameter to the value of FBA D SET 10 makes data set 10 the first data set to be used for communication between the NIBA-01 and the drive. FBA D SET 1; FBA D SET 10 ABB drives can receive control information from multiple sources including digital inputs, analogue inputs, the drive control panel and a communication module (e.g. NIBA-01). ABB drives allow the user to separately determine the source for each type of control information (Start, Stop, Direction, Reference, Fault Reset, etc.). In order to give the fieldbus master station the most complete control over the drive, the communication module must be selected as source for this information. See the user documentation of the drive for information on the selection parameters. NIBA-01 Installation and Start-up Guide 5-3
24 Chapter 5 Programming Host Configuration The devices on the remote bus are automatically detected by the host controller software, and then assigned input and output memory addresses. The need for further configuration depends on the host controller software and the application. The configuration data in Table 5-2 below is valid for the NIBA-01. Table 5-2 Host controller configuration data for the NIBA-01 module. Communication Parameter Value Device Name/Type ID Code Length Code NIBA-01 PCP Mode: 243 (F3h) IO Mode: 3 (03h) 4 (04h) No. of Process Data Bytes In/Out 6/6 No. of Parameter Data Bytes In/Out 2/2 Register Length (bytes) 8 Profile No. 0 Services Supported Maximum PDU Length All mandatory services, Get OV, Read, Write 64 bytes COMMUNICATION REFERENCE LIST ENTRIES Max-PDU Sending-High-Prio 0 Max-PDU Sending-Low-Prio 64 bytes Max-PDU Receiving-High-Prio 0 Max-PDU Receiving-Low-Prio 64 bytes PMS-Services-Supported / ; Client / Server 5-4 NIBA-01 Installation and Start-up Guide
25 Chapter 5 Programming Calculating the Optimal Cycle (Scan) Time For fast data transfer, the host controller should send the message frame (detailed in Chapter 6) as frequently as possible. However, the slave stations on the bus may not be able to follow if the cycle time (scan time) is too short. The cycle time can be calculated using the following formula: t cycle = ( 13 ( 6 + n ) m ) t Bit + t SW + t PH where t cycle n m t Bit t SW t PH Transfer time in milliseconds Number of user data bytes Number of remote bus modules installed Bit duration (0.002 ms for 500 kbit/s) Software runtime (0.2 ms) Runtime on the transmission medium (for copper, ms l/km, where l = remote bus cable length in kilometres) Note: The minimum cycle time with the NIBA-01 is 1 ms. NIBA-01 Installation and Start-up Guide 5-5
26 Chapter 5 Programming 5-6 NIBA-01 Installation and Start-up Guide
27 Chapter 6 Communication Overview InterBus-S Message Frame This chapter describes the messaging used in InterBus-S communication. Further information is available from the host controller documentation, Phoenix Contact ( and the INTERBUS Club ( The InterBus-S system employs so-called summation frames. The host controller cyclically sends a message frame that includes the process data for every module on the bus. The frame is constructed by the host controller using the configuration data entered previously for each module on the bus. As the message frame is relayed through the system, each device on the bus stores the information addressed to it in a buffer and responds by writing a response message into the same position in the frame. As the message frame returns to the host controller, it is checked against the original message. VALUE 5th CYCLE VALUE INDEX 4th CYCLE INDEX SERVICE 3rd CYCLE SERVICE HEADER 2nd CYCLE HEADER LOOP CHECK PROCESS DATA PROCESS DATA PARAM- ETER PROCESS DATA PARAM- ETER PROCESS DATA PROCESS DATA MODULE 1 MODULE 2 MODULE 3 MODULE n-1 MODULE n FRAME CHECK SEQUENCE CONTROL 2 BYTES 2 BYTES 4 BYTES 4 BYTES 8 BYTES 2 BYTES 2 BYTES 2 BYTES BYTE 1 BYTE 2 BYTE 3 BYTE 4 BYTE 5 BYTE 6 BYTE 7 BYTE 8 IN (HOST TO DRIVE) *PCP CHANNEL / **INDEX DATA SET 1 DATA WORD 1 (DW 1.1) CONTROL WORD (CW) DATA SET 1 DATA WORD 2 (DW 1.2) REFERENCE 1 (REF1) DATA SET 1 DATA WORD 3 (DW 1.3) REFERENCE 2 (REF2) OUT (DRIVE TO HOST) *PCP CHANNEL / **INDEX DATA SET 2 DATA WORD 1 (DW 2.1) STATUS WORD (SW) DATA SET 2 DATA WORD 2 (DW 2.2) ACTUAL VALUE 1 (ACT1) DATA SET 2 DATA WORD 3 (DW 2.3) ACTUAL VALUE 2 (ACT2) *USED IN PCP MODE ONLY (SEE PCP SERVICES SUPPORTED BY NIBA-01 BELOW). **USED IN I/O MUXED MODE ONLY. Figure 6-1 InterBus-S message frame. NIBA-01 Installation and Start-up Guide 6-1
28 Chapter 6 Communication PCP Services Supported by NIBA-01 The PCP services presented below are supported (in PCP Mode) by the NIBA-01 InterBus-S Adapter Module. Note: The Command Codes given are valid for Generation 4 Phoenix Contact host controllers (equipped with an LCD display). Generation 3 controllers (equipped with an LED display) require the substitution of 8 for the first 0 (e.g. 808Bh for 008Bh). Service Command Codes Message Codes Request Response Indication Confirmation READ 0081h 00A1h 01A1h 0181h WRITE 0082h 00A2h 01A2h 0182h STATUS 0086h 0186h IDENTIFY 0087h 0187h GET OV 0088h 0188h INITIATE INITIATE ERROR 008Bh 00ABh 00ACh 01ABh 018Bh 018Ch ABORT 008Dh 01ADh Appendix A Definitions and Abbreviations contains basic explanations for the byte names used. The following values are applicable to all the PCP services supported. : The number of words (of 2 bytes each) to follow (in hexadecimal) Invoke ID: For NIBA-01, 00 Comm.Ref.: The Communication Reference (module number) assigned for the NIBA-01 upon host configuration (in hexadecimal) Password: For NIBA-01, 00 Index: ((Drive Param. No.) ), converted to hexadecimal Subindex: For NIBA-01, 00 Error Codes: Error Error Additional Class Code Code (hex) Explanation No access Invalid subindex Data too long Data too short Object is not a parameter Object does not exist Service cannot be executed Service cannot currently be executed Parameter value too high Parameter value too small 6-2 NIBA-01 Installation and Start-up Guide
29 Chapter 6 Communication Read Reads a parameter value from the drive via NIBA-01. Read Request: Command Code (0081h) Index* Subindex Example of a Read Request (Param ): eg. 02 3B CB 00 Read Response (+): Command Code (00A1h) Result (+) Length Data Data Read Response ( ): Command Code (00A1h) Result ( ) Error Class Error Code Add. Code Add. Code Read Indication: Message Code (01A1h) Index* Subindex Read Confirmation (+): Message Code (0181h) Result (+) Length Data Data Read Confirmation ( ): Message Code (0181h) Result ( ) Error Class Error Code Add. Code Add. Code *Index: ((Drive Param. No.) ), converted to hexadecimal NIBA-01 Installation and Start-up Guide 6-3
30 Chapter 6 Communication Write Writes a parameter value to the drive via NIBA-01. Write Request: Command Code (0082h) Index* Subindex Length Data Example of a Write Request (Param set to 1000): e.g E8 Data Write Response (+): Command Code (00A2h) Result (+) Write Response ( ): Command Code (00A2h) Result ( ) Error Class Error Code Add. Code Add. Code Write Indication: Message Code (01A2h) Index* Subindex Length Data Data Write Confirmation (+): Message Code (0182h) Result (+) Write Confirmation ( ): Message Code (0182h) Result ( ) Error Class Error Code Add. Code Add. Code *Index: ((Drive Param. No.) ), converted to hexadecimal 6-4 NIBA-01 Installation and Start-up Guide
31 Chapter 6 Communication Status Displays NIBA-01 status. Status Request: Command Code (0086h) Status Confirmation (+): Message Code (0186h) Result (+) Log. Status Phys. Status Length String of Local Status Confirmation ( ): Message Code (0186h) Result ( ) Error Class Error Code Add. Code Add. Code Detail Logical Status: Physical Status: 1 = Limited number of services 0 = Ready to communicate 0 = Ready for operation NIBA-01 Installation and Start-up Guide 6-5
32 Chapter 6 Communication Identify Displays NIBA-01 identification data. Identify Request: Command Code (0087h) Identify Confirmation (+): Message Code (0187h) Result (+) Length String of Vendor Str. of Vendor Identify Confirmation ( ): Message Code (0187h) Result ( ) Error Class Error Code Add. Code Add. Code Length Str. of Module String of Module Length Str. of Rev. String of Revision Vendor: ABB Industry Oy Model: NIBA-01 Revision: Rev. SW x.x HW x 6-6 NIBA-01 Installation and Start-up Guide
33 Chapter 6 Communication Get OV Reads the object dictionary from the drive in short form. The three words returned are the requested index, object code, and data type and length. Get OV Request: Command Code (0088h) All-Attrib. Access-Spec. Index or Name Get OV Confirmation (+): Message Code (0188h) Result (+) More-Follows Length List of O.D. List of Object Description Get OV Confirmation ( ): Message Code (0188h) Result ( ) Error Class Error Code Add. Code Add. Code List of Object Description NIBA-01 Installation and Start-up Guide 6-7
34 Chapter 6 Communication Initiate Initiates communication between the InterBus-S host and the NIBA-01. Initiate Request: Command Code (008Bh) Password Acc_groups Example of an Initiate Request: 00 8B eg Initiate Response: Command Code (00ABh) Password Acc_groups Initiate Error Response: Command Code (00ACh) Add. Code Initiate Indication: Message Code (01ABh) Version Length Str. of Profile Str. of Profile Protection Acc_groups Password Initiate Confirmation (+): Message Code (018Bh) Result (+) Version Version Length String of Profile Str. of Profile Protection Password Acc_groups Initiate Confirmation ( ): Message Code (018Ch) Result ( ) Error Class Error Code Send High Send Low Receive High Receive Low Su.Services Supported Services Supported Services Su.Services 6-8 NIBA-01 Installation and Start-up Guide
35 Chapter 6 Communication Abort Aborts the connection between the host and the NIBA-01. Abort Request: Command Code (008Dh) Comm.Ref. Abort Detail Abort Indication: Message Code (01ADh) Comm.Ref. Locally_gen. Abort_id Reason_code Abort_detail NIBA-01 Installation and Start-up Guide 6-9
36 Chapter 6 Communication The Control Word and the Status Word References Actual Values The Control Word is the principal means for controlling the drive from a fieldbus system. It is sent by the fieldbus master station to the drive, the adapter module acting as a transparent link. The drive switches between its states according to the bit-coded instructions on the Control Word. The Status Word is a word containing status information, sent by the drive to the master station. The contents of both the Control and Status Words are explained in the drive documentation. The Control and Status Words are not altered by the NIBA-01 in any way, excepting Bit 15 of the Status Word, which is turned on by the module in case of an error in the DDCS communication between the module and the drive. References are 16-bit words containing a sign bit and a 15-bit integer. A negative reference (indicating reversed direction of rotation) is formed by calculating the two s complement from the corresponding positive reference. ABB drives can receive control information from multiple sources including analogue and digital inputs, the drive control panel and a communication module (e.g. NIBA-01). In order to have the drive controlled through Interbus-S, the communication module must be defined as the source for control information, eg. Reference. The scaling of the integer received from the master as Reference is drivespecific. See its Programming Manual for available control source selections and Reference scaling factors. Actual Values are 16-bit words containing information on the operation of the drive. The functions to be monitored are selected with a drive parameter. The scaling of the integers sent to the master as Actual Values depends on the selected function. Please refer to the drive documentation NIBA-01 Installation and Start-up Guide
37 Appendix A Definitions and Abbreviations Abort Abort Detail Access Groups Acyclic Communication Add. Code Client Communication Object Service to abort the communication connection Application-specific, detailed designation for the abort Identification about the allocation of group access Communication in which messages are sent only once on request Application-specific, detailed designation of the error Communication Reference Module number of a station Communication Relationship List Confirmation Control Word Cyclic Communication Error Class/Error Code Error Code Fault Host (Controller) Index Initiate Invoke ID KBL KR Length Locally Generated Log. Status Object Dictionary Original Invoke ID Service requester; the communication partner who requests an order Data, programs or variables which may be processed or executed Contains definitions (permitted services, read and write memory sizes) regarding the communication channels Order confirmation which the service provider sends to the service requester (client) 16-bit word from master to slave with bit-coded control signals. (Sometimes called the Command Word) Communication in which Parameter/Process Data Objects are sent cyclically at pre-defined intervals Classification number of an error Error number of the service Event that leads to tripping of the device Control system with bus initiative. Also called Master Access reference for communication objects; pointer to a variable/field Service to establish a communication relationship Order identification, request no. of the service to a station See Communication Relationship List See Communication Reference Quantity of the following user data in bytes Error location. (Local station: 00; Remote station: FF) Status of the module program Local storage of all Communication Objects recognised by a device Invoke ID of the service which caused a reject NIBA-01 Installation and Start-up Guide A-1
38 Appendix A Definitions and Abbreviations OV Password PCP Phys. Status Primitive Process Data Profile Protection Reason Code See Object Dictionary Password for the access control Peripherals Communication Protocol. Also, an operating mode of the NIBA-01 for transferring parameter data Status of the module hardware Basic operation of a service Data that contains Control Word and Reference value or Status Word and Actual value. May also contain other control information Adaptation of the protocol for certain application field, e.g. drives The value of the access check. (00: Protection off; FF: Protection on) Error code for the connection release Receive High High-priority send buffer size. (Always 00) Receive Low Reject Reject Code Request Response Result Low-priority send buffer size (in bytes) Service, designation of the service type which indicates a non-allowable access to a station Designation of the error cause which initiated the reject Service request by the client Sending of the order confirmation by the server after the order has been executed Acknowledgement result of a service (positive: 00; negative: 01 to FF) Send High High-priority send buffer size. (Always 00) Send Low Server Slave Status Word String of Module String of Profile String of Revision String of Vendor Subindex Supported Services Low-priority send buffer size (in bytes) Service provider Passive bus participant 16-bit word from slave to master with bit-coded status messages Module type designation as a data string, the length of which is specified with Length Module profile as a data string, the length of which is specified with Length Module revision as a data string, the length of which is specified with Length Manufacturer name as a data string, the length of which is specified with Length Pointer to a location in a variable/field 6-word code of the supported services A-2 NIBA-01 Installation and Start-up Guide
39 Appendix B Technical Data DDCS Link Compatible Devices: All ABB Fieldbus Adapter modules, ABB ACS 300, ACS 600 SingleDrive, ACS 600 MultiDrive, ACS 600 MotionControl, ACF 600 Pump & Fan Drive, DCS 500 Size of the Link: 2 stations Medium: Fibre optic cable Construction: Plastic core, diameter 1 mm, plastic sheathing Attenuation: 0.31 db/m Maximum Length between Stations: 10 m Specifications: Parameter Minimum Maximum Unit Storage Temperature C Installation Temperature C Short Term Tensile Force 50 N Short Term Bend Radius 25 mm Long Term Bend Radius 35 mm Long Term Tensile Load 1 N Flexing 1000 cycles Topology: Ring Serial Communication Type: Asynchronous, half Duplex Transfer Rate: 4 Mbit/s Protocol: Distributed Drives Communication System (DDCS) Connectors: Blue receiver; grey transmitter NIBA-01 Installation and Start-up Guide B-1
40 Appendix B Technical Data InterBus-S Topology: Ring Protocol: Defined in DIN E Maximum Remote Bus Length: 12.8 km Maximum Remote Bus Segment Length: 400 m Maximum No. of Remote Bus Segments: 32 Maximum No. of Remote I/O Stations: 256 Medium: RS-485 cable, 3 x 2 (twisted pairs), common shield Serial Communication Type: Asynchronous, full duplex Transfer Rate: 500 kbit/s Minimum Bus Cycle (Scan) Time: 1 ms B-2 NIBA-01 Installation and Start-up Guide
41 Appendix B Technical Data NIBA-01 Enclosure: Plastic, dimensions mm; degree of protection IP 20 Mounting: Onto a standard mounting rail Settings: Via drive interface (Control panel) Current Consumption: 160 ma at 24 V d.c. Communication Parameters: Communication Parameter Value Device Name/Type ID Code Length Code NIBA-01 PCP Mode: 243 (F3h) IO Mode: 3 (03h) 4 (04h) No. of Process Data Bytes In/Out 6/6 No. of Parameter Data Bytes In/Out (PCP Mode only) 2/2 Register Length (bytes) 8 Profile No. 0 Services Supported Maximum PDU Length All mandatory services, Get-OV, Read, Write 64 bytes COMMUNICATION REFERENCE LIST ENTRIES Max-PDU Sending-High-Prio 0 Max-PDU Sending-Low-Prio 64 bytes Max-PDU Receiving-High-Prio 0 Max-PDU Receiving-Low-Prio 64 bytes PMS-Services-Supported / ; Client / Server NIBA-01 Installation and Start-up Guide B-3
42 Appendix B Technical Data Connectors: Light transmitter (grey) and receiver (blue) for connection to the drive Two Combicon MVSTBW 2,5/8-ST-5,08 (8-pole, cross-section 2.5 mm 2 max.) screw terminal blocks for the fieldbus and power supply: X1 (IN) 1 0V 2 +24V Description Power supply for the module 24 V d.c. ± 10 %; maximum power consumption 160 ma 3 DG1 Signal Ground 4 /DI1 Data in 1 (Inverted) 5 DI1 Data in 1 6 /DO1 Data out 1 (Inverted) 7 DO1 Data out 1 8 SHF Filtered Shield (Connected to module earth via an RC filter) X2 (OUT) Description 1 SH Shield (Module earth) 2 DI2 Data in 2 3 /DI2 Data in 2 (Inverted) 4 DO2 Data out 2 5 /DO2 Data out 2 (Inverted) 6 DG2 Signal Ground 7 RBST Remote Bus Connector 8 RB5V Signal +5V General: All materials are UL/CSA approved Complies with EMC Standards EN and EN B-4 NIBA-01 Installation and Start-up Guide
43 Appendix C Ambient Conditions Ambient Conditions, Operation Ambient Conditions, Storage Ambient Conditions, Transportation Ambient operating conditions refer to the conditions the adapter module is subjected to when installed for stationary use. Air Temperature: 0 to +50 C Relative Humidity: 5 to 95 %, no condensation allowed. Maximum allowed relative humidity is 60 % in the presence of corrosive gases. Contamination Levels: Chemical gases: IEC , Class 3C2 Solid particles: IEC , Class 3S2 Installation Site Altitude: 0 to 2000 m. If installation site is above 2000 m, contact local ABB representative. Vibration: Max 0.3 mm (2 to 9 Hz), max 1 m/s 2 (9 to 200 Hz) sinusoidal (IEC ) Shock: Max 70 m/s 2, 22 ms (IEC ) Ambient storage conditions refer to the conditions the adapter module is subjected to during storage in the protective package. Temperature: -40 to +70 C. Relative Humidity: Less than 95 %, no condensation allowed Atmospheric Pressure: 70 to 106 kpa Vibration: Max 1.5 mm (2 to 9 Hz), max 5 m/s 2 (9 to 200 Hz) sinusoidal (IEC ) Shock: Max 100 m/s 2, 11 ms (IEC ) Ambient transportation conditions refer to the conditions the adapter module is subjected to during transportation in the protective package. Temperature: -40 to +70 C Relative Humidity: Less than 95 %, no condensation allowed. Atmospheric Pressure: 60 to 106 kpa Vibration: Max 3.5 mm (2 to 9 Hz), max 15 m/s 2 (9 to 200 Hz) sinusoidal (IEC ) Shock: Max 100 m/s 2, 11 ms (IEC ) Bump: Max 300 m/s 2, 6 ms (IEC ) Free Fall: 250 mm NIBA-01 Installation and Start-up Guide C-1
44 Appendix C Ambient Conditions C-2 NIBA-01 Installation and Start-up Guide
45
46 NIBA-01/EN 3AFY REV B EFFECTIVE: ABB Oy AC Drives P.O. Box 184 FI HELSINKI FINLAND Telephone: Fax: Internet:
Installation and Start-up Guide. CS 31 Adapter Module NCSA-01
ABB Drives Installation and Start-up Guide CS 31 Adapter Module NCSA-01 CS 31 Adapter Module NCSA-01 Installation and Start-up Guide 3BFE 58920029 R0225 EFFECTIVE: 1.12.1999 SUPERSEDES: 1996-02-01 1999
ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions
ACS800. Master/Follower Application Guide Supplement to Firmware Manual for ACS800 Standard Application Program
ACS800 Master/Follower Application Guide Supplement to Firmware Manual for ACS800 Standard Application Program Master/Follower Application Guide Supplement to Firmware Manual ACS800 Standard Application
ABB Drives. User s Manual HTL Encoder Interface FEN-31
ABB Drives User s Manual HTL Encoder Interface FEN-31 HTL Encoder Interface FEN-31 User s Manual 3AUA0000031044 Rev B EN EFFECTIVE: 2010-04-06 2010 ABB Oy. All Rights Reserved. 5 Safety instructions
MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
Rack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
ABB i-bus EIB / KNX Analogue Input AE/S 4.2
Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion
Telephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
Vibration Monitoring System Adash 3600
" User's guide Application: Vibration Monitoring System Adash 3600! Vibration diagnostics, monitoring and protective on-line system! On-line vibration monitoring system of engines, fans, pumps, gearboxes,
SIMATIC NET. CP 243-2 AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program
Preface Contents SIMATIC NET CP 243-2 AS-Interface Master Manual Technical Description and Installation Instructions Interface to the User Program 2 in the S7-200 CPU Access to the Data of the AS-i Slaves
Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111
, GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,
ABB Drives. Protocol Manual - Modbus/TCP Ethernet Adapter Module FENA-01
ABB Drives Protocol Manual - Modbus/TCP Ethernet Adapter Module FENA-01 Ethernet Adapter Module - Modbus/TCP FENA-01 Protocol Manual 3AUA0000022989 REV B EN EFFECTIVE: 2009-11-01 2009 ABB Oy. All Rights
TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
GE Power Controls FIELDBUS APPENDIX PROFIBUS DP. Doc. No.: ASTAT Plus PB_Appendix-v0
GE Power Controls = FIELDBUS APPENDIX PROFIBUS DP = Doc. No.: ASTAT Plus PB_Appendix-v0 Fieldbus Appendix: PROFIBUS DP 1 Fieldbus Introduction...... 2 1.1 Introduction to Profibus-DP... 2 1.2 Network Overview...
Waveguide Access Point WGA631. Product Guide
Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................
Hardware Specifications of V2AF Series Hybrid Card Reader
B (1/ 14) Hardware Specifications of V2AF Series Hybrid Card Reader Rev. A Sep. 28, 1999 Rev. B Feb. 22, 2000 Card Business Promotion Division OMRON Corporation 1999 All Rights Reserved O M R O N B (2/
DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual
DVPPF02-H2 PROFIBUS DP Slave Communication Module Application Manual Warning Please read this instruction carefully before use and follow this instruction to operate the device in order to prevent damages
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Installation and start-up guide NETA-21 remote monitoring tool
Remote monitoring options for ABB drives, converters and inverters Installation and start-up guide NETA-21 remote monitoring tool 3AUA0000096881 REV C Effective: 2013-03-01 2013 ABB Oy. All rights reserved.
NC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
Combi switchbox with integrated 3/2 way pilot valve
H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
CQM1-SF200/CS1W-SF200
Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit
Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11
Communication Unit 560CMD11 The SLC works as master for the RTU560 serial peripheral bus (I/O-Interface/ Wired-OR-Bus ). The MPU is responsible for the other tasks. The MPU handles the absolute time and
IntesisBox KNX Modbus RTU master
IntesisBox KNX RTU master Gateway for integration of RTU devices into KNX control systems. Integrate RTU devices (Chillers, Roof Tops, electricity meters, heating floors, heat pumps, PLCs ) into KNX control
Documentation. M-Bus 130-mbx
Documentation M-Bus 130-mbx Introduction The mx M-Bus module is part of the mx Smart Slot communications family. With the integrated SmartSlot technology, mx systems ag offers automatic consumer data read-out
IntesisBox Modbus Server SAMSUNG Air Conditioners
IntesisBox Modbus Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung NASA compatible Air Conditioning Systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI,
Safety Manual BT50(T) Safety relay / Expansion relay
Safety Manual BT50(T) Safety relay / Expansion relay ABB Jokab Safety Varlabergsvägen 11, SE-434 39, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this document
IntesisBox KNX Modbus TCP master
IntesisBox KNX TCP master Gateway for integration of TCP slave devices into KNX control systems. Integrate any TCP slave device into KNX. KNX TCP slave EIB Bus IntesisBox Ethernet slave LinkBoxEIB Configuration
CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual
Instruction Manual OPC-LM1-IL Option Card for Encoder of Line Driver Output CAUTION Deliver this instruction manual without fail to those who actually operate the equipment. Read this operation manual
IntesisBox KNX - LON
IntesisBox KNX - Gateway for integration of devices into KNX systems. Integrate Air Conditioning from the main manufacturers (DAIKIN, Mitsubishi Electric, Mitsubishi Heavy Industries, Toshiba, Fujitsu,
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
HARTING mcon 1000 Introduction and features
Introduction and features HARTING mcon 1000 es, managed, for mounting onto top-hat mounting rail in control cabinets General Description Features Supporting Ethernet (10 Mbit/s), Fast Ethernet (100 Mbit/s)
EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014
EZmoto V2 Product description Rev. 6 10/01/2014 1 Contents 1. Overview... 3 2. Hardware Interface Description... 3 2.1 Main features of the EZmoto... 3 2.2 Hardware block diagram... 4 2.3 Internal Hardware
Voltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
We hope that every customer sets up CC-Link system easily by reading this documentation.
This documentation describes items to consider in advance, how to select devices, points to keep in mind and procedure in order to set up cable wiring. Abstract of contents Chapter 1: Procedure for cable
Disturbance Recoder SPCR 8C27. Product Guide
Issued: April 1999 Status: Updated Version: C/26.04.2006 Data subject to change without notice Features Versatile digital disturbance recorder module for recording various phenomena in the electric power
IntesisBox KNX LG Air Conditioning
IntesisBox KNX LG Air Conditioning Gateway for integration of LG Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB) bus. Direct connection to LG outdoor unit
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
MAKING MODERN LIVING POSSIBLE. UniLynx Indoor User Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS
MAKING MODERN LIVING POSSIBLE UniLynx Indoor User Manual ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS Contents Contents 1. Introduction 2 Introduction 2 2. Function Description 3 Definition
ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1
Product Manual ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1 Intelligent Installation Systems This manual describes the function of the EIB monitoring module EUB/S 1.1 with the Application program
ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011
, 2CDG 110 1xx R0011 SA/S 8.16.6.1 2CDC 071 006 S0010 The 16/20 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are especially
Modbus Server SAMSUNG Air Conditioners
IntesisBox Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung Air Conditioning Systems from any master device TCP or RTU (BMS, PLC, SCADA, HMI, TouchPanel ) Master TCP Master
Product Manual. ABB i-bus KNX Data Logging Unit BDB/S 1.1. Intelligent Installation Systems ABB
Product Manual ABB i-bus KNX Data Logging Unit BDB/S 1.1 Intelligent Installation Systems ABB This manual describes the function of the Data Logging Unit BDB/S 1.1. Subject to changes and errors excepted.
EXTERNAL DIMENSIONS AND PARTS
FX2N-4DA SPECIAL FUNCTION BLOCK USER S GUIDE JY992D65901A This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation of the FX2N-4DA special
EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM
EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM INSTALLATION MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273
Light scene push button 8gang comfort flush-mounted 751688xx
751688xx Documentation Product name: Light scene push button 8gang comfort Design: flush-mounting type (Up) ETS search path: Push button / Push button general / Light scene push button 8gang comfort Functional
MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference : 9010709-03
MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE USER GUIDE Document reference : 9010709-03 If you have questions about the MDM192 or desire assistance, contact ETIC TELECOMMUNICATIONS at the following
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
Remote Monitoring and REC 501 Control Unit Product Guide
Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the
How To Use A Power Supply On A Powerline 2.2 (Ai)
KNX/EIB Product documentation Issue: 05.08.2010 629x1220 Push button sensor 3 comfort 1-gang Push button sensor 3 comfort 2-gang (1+1) Push button sensor 3 comfort 3-gang Push button sensor 3 comfort 4-gang
CB15/CB155. PROFIBUS Module
CB15/CB155 PROFIBUS Module Contents Warning and Caution Notes 1. OVERVIEW 1.1 Description and Features 1.2 Application on a PROFIBUS Link 2. INSTALLATION 2.1 Installing the Module 2.1.1 CB15 Installation
Energy Communication Unit (ECU)
Altenergy Power System Energy Communication Unit (ECU) Installation and User Manual (For ECU-3 V3.7) Version:3.0 ALTENERGY POWER SYSTEM INC. All rights reserved TABLE OF CONTENTS 1.0 Introduction... 2
Instruction Manual Copy Adapter "CPAD-C1A" "CP Fuji Electric Systems Co., Ltd. INR-SI47-0886a-EU Rev 052010
Instruction n Manual Copy Adapter "CPAD-C1A" Thank you for purchasing our Copy Adapter CPAD-C1A. This product is designed to copy function codes and their data, which are stored in the FRENIC-Mini series
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
Original instructions Tina 3A/Aps Adaptor unit
Original instructions Tina 3A/Aps Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this
FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology
FOSTCDR pn 8684R1 FOSTCDR-0812ds page 1/5 Industrial Serial to Multimode Fiber Optic Converter Data Rates up to 115.2 kbps 2.5 Mile (4 km) Range 10 to 30 VDC Input Voltage Wide Operating Temperature 2000V
Fieldbus slave modules with I/Os, DIO
140 Fieldbus slave modules with I/Os, DIO 1534CF00 1534CH00 1534PF00 1534PH00 1536CH00 1536CL10 1536PH00 1536PL00 Order number 1534CF00 1534CH00 1534PF00 1534PH00 Figure Type SM 153, CANopen slave, DIO
Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION
Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature
IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.
IntesisBox KNX SAMSUNG Air Conditioning Gateway for integration of Samsung air conditioners into KNX control systems. Integrate Samsung Air Conditioners into KNX. KNX EIB Bus IntesisBox RS485 MIM-B13x/B04A
MOUNTING AND OPERATING INSTRUCTIONS
MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall
TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev.
TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. 0 1. Generality 3 2. Introduction 3 3. Accessories and Options 3 4. Installation 3 5. Connection
CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual
CelluLine CGW-TS GSM Cellular Gateway Installation and Programming Manual CelluLine CGW-TS GSM Cellular Gateway Installation and Programming Manual CGWTS-M001A Version 1, Release 1, December 2004 NOTICE
IntesisBox KNX Mitsubishi Heavy Industries AC
IntesisBox KNX Mitsubishi Heavy Industries AC Gateway for integration of Mitsubishi Heavy Indsutries (MHI) Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB)
PD 100A. Printing data system
PD 100A Printing data system Operating instructions ENGLISH IMPORTANT: Read these instructions carefully before installing and using the device; do not forget following all additional information. Keep
Adjustment functions for both span and shift have been incorporated
SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8
EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.
Wafer-carrier Mounting Photomicrosensors EE-SPY1/ CSM_EE-SPY1 DS_E_3_ Photomicrosensors for detecting wafer-carrier mounting. The mounting position is set with a pedestal. The contact surface with the
CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
Global Drive. Lenze INTERBUS. Communication manual
INTERBUS Communication manual Lenze Global Drive 1 Preface Contents 1.1 1 Preface 1.1 Contents 1.2 Introduction... 1.2-1 1.3 Comparison of industrial fieldbus systems... 1.3-1 1.4 About this Communication
Solarcheck string monitoring. User manual
Solarcheck string monitoring User manual User manual Solarcheck string monitoring 2013-06-14 Designation: Revision: UM EN Solarcheck String Monitoring 00 This user manual is valid for: Designation Order
DeviceNet Communication Manual
DeviceNet Communication Manual Soft-Starter Series: SSW-07/SSW-08 Language: English Document: 10000046963 / 00 03/2008 Summary ABOUT THIS MANUAL... 5 ABBREVIATIONS AND DEFINITIONS... 5 NUMERICAL REPRESENTATION...
Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!
Documentation Brake module AX5021 Please read this document carefully before installing and commissioning the brake module! Version : 1.2 : 2012.03.05 Date Article-no. : TDmlAX-5021-0000-0200 Page 2/8
PCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
Multifunction devices
devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2
WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK
WEA-Base User manual for load cell transmitters 1 Contents 1. Technical data... 3 2. Assembly... 4 2.1 Power supply... 4 2.2 Load cells... 4 2.3 RS-485... 4 2.4 Relays... 5 2.5 Digital input... 5 2.6 Analogue
Operating Manual UWAPS-TINY Series
Operating Manual UWAPS-TINY Series Powecon Oy WWW.POWECON.FI 1/9 Table of content 1 Warranty...3 2 Safety information...3 3 Abbreviations and terminology...3 4 List of appendices...4 5 Introduction...4
R.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
CompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
CMC-DN01 DeviceNet Slave Communication Card Operation Manual
CMC-DN01 DeviceNet Slave Communication Card Operation Manual 2011-12-26-A Warning This operation manual provides introduction on the functions, specifications, installation, basic operation and settings
Install the DeviceNet Module using the following procedure:
Installation INSTALLATION INSTRUCTIONS: MCD DEVICENET MODULE Order Code: 175G9002 1. Installation Install the DeviceNet Module using the following procedure: 1. Remove control power and mains supply from
IBS IP KIS A. Data Sheet INTERBUS-S. Digital I/O Module
IBS IP KIS A Data Sheet Digital I/O Module Data Sheet Revision C Product Description The IBS KIS IP A module is a digital I/O module for the extended installation remote bus. Features - InterBuS-S protocol
CMC-PD01 PROFIBUS DP Slave Communication Card Operation Manual
CMC-PD01 PROFIBUS DP Slave Communication Card Operation Manual CMC-0205820-01 Table of Content 1 Introduction to CMC-PD01... 2 1.1 Product Introduction... 2 1.2 Features... 2 2 Product Profile and Outline...
MultiViu Flex 7 Data Sheet
Division Interior MultiViu Flex 7 Data Sheet Picture: MultiViu Flex 7 Picture: MultiViu Flex 7 Description CAN-capable multifunction Solution Features: Robust and versatile design CAN-capability (SAE J1939,
Energy Communication Unit (ECU)
Altenergy Power System Energy Communication Unit (ECU) Installation and User Manual (For ECU-3 V3.8) ALTENERGY POWER SYSTEM INC. All rights reserved TABLE OF CONTENTS 1.0 Introduction... 2 2.0 Installation...
Model: DC-A2IO Advanced HVAC Controller
Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA
RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System
RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System RTM X42 is an innovative system that utilizes force measuring rollers to capture the tension of individual wires or strands,
BETAtrans. Cables and Systems for Rolling Stock. Edition 2006
BETAtrans Cables and Systems for Rolling Stock. Edition 2006 Info Consulting and Sales By Phone To ask for Information or to place an order please use the following number: +49 (0)9172-6844-11 By Fax For
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
MANUAL FOR RX700 LR and NR
MANUAL FOR RX700 LR and NR 2013, November 11 Revision/ updates Date, updates, and person Revision 1.2 03-12-2013, By Patrick M Affected pages, ETC ALL Content Revision/ updates... 1 Preface... 2 Technical
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
Contents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
TX OPEN RS232/485 module
s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the
EDK 350 (868 MHz) EDK 350U (902 MHz) EnOcean Developer Kit
EDK 350 (868 MHz) EDK 350U (902 MHz) EnOcean Developer Kit EDK 350 User Manual Important Notes This information describes the type of component and shall not be considered as assured characteristics. No
T7560A,B,C Digital Wall Module
T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital
A1000 Cheat Sheet (Open Loop Vector)
A1000 Cheat Sheet (Open Loop Vector) The following procedure is a supplement to supplied with this equipment and will guide the user in properly wiring the A1000 and. It will also show the user how to
Electronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite: www.gsm-m2m.com
DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite: www.gsm-m2m.com This handbook has been designed as a guide to the installation and operation of King Pigeon Hi-Tech.Co.,Ltd DAM series. Statements
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
Wind Sensor W-RS485 with RS485 Interface
Wind Sensor W-RS485 with RS485 Interface Technical data and notes for installation Elsner Elektronik GmbH Steuerungs- und Automatisierungstechnik Herdweg 7 D-75391 Gechingen Germany Phone: +49 (0) 70 56/93