1 Issue 4.1 Data Centre Solutions RACKS POWER COOLING MONITORING SECURITY SERVICE & SUPPORT
2 The simple route to the perfect data centre Data centres are complex systems. Software, hardware and IT infrastructure must work together seemlessly to supply the user with energy and cost effi cient, reliable IT services. The IT infrastructure alone demands a wide variety of specialists from each fi eld including: climate control, power ditribution and security. Rittal - The System, minimises complexity and reduces interfaces through a complete, integrated solution. Superior IT performance is achieved through perfect coordination of the Rittal IT System modules: Racks, Power, Cooling, Security, Monitoring & Remote Management, all complimented by a comprehensive range of software and services. Data Centre Solutions presents you with a complete overview of the Rittal IT System. Peter Mellino Managing Director Rittal Australia and New Zealand RACKS POWER COOLING rittaldatacentre.com.au
3 Contents NETWORK ENCLOSURES & SERVER RACKS 4 Corporate Racks 4 High Performance Cooling Racks 5 Rack Acessories 6 POWER DISTRIBUTION/ POWER BACKUP 10 Ri4Power System Solutions 12 UPS Technology 13 UPS Batteries 14 UPS Monitoring 15 The Rittal UPS Family 16 UPS PMC UPS PMC UPS Power Module Concept 20 UPS PMC UPS PMC UPS Acessories 25 Power Distribution Rack (PDR) 26 Horizontal & Vertical Power Rails 27 Monitored & Controlled Power Rails 28 Power System Module (PSM) 30 Battery Monitoring 34 CLIMATE CONTROL 36 High End Solutions 36 Rittal Liquid Cooling Package (LCP) 38 Rack Climate Control 40 Row Based Cooling 41 Liquid Cooling Packages (LCP) 42 Aisle Containment 46 CRAC Systems 47 IT Chillers 48 Alternative Cooling 49 MONITORING 50 CMC III Monitoring Systems 52 CMC III Processing Unit/Compact 54 CMC III Accessories 55 CMC III Processing Unit/Compact - System Overview 56 CMC III Processing Unit - System Overview 57 CMC III Sensors/Accessories 58 Dynamic Rack Control 59 RiZone 62 SECURITY SOLUTIONS 65 IT Security Solutions 65 IT Security Rooms 66 IT Security Safes 69 Modular Safe Extend 70 Modular Safe Light & Basic Safe Compact 71 Fire Alarm & Extinguisher Systems 72 DATA CENTRE CONTAINERS 74 Data Centre Construction & IT Infrastructures 76 SERVICE & SUPPORT 78 Engineering & Design 78 Rittal Global Service 79 NOTES 80 REFERENCES Back cover MONITORING SECURITY SERVICE & SUPPORT 1 rittaldatacentre.co.nz
4 Data centres that are perfect in every detail! A perfect IT environment provides the basis for perfect business. Rittal plans, builds and optimises data centres on your behalf, thereby making an effective and effi cient contribution to your corporate success. We will advise, design and develop solutions that fi t your business perfectly. The benefits to you: You benefi t from the opportunities offered by a complete supplier. From the initial draft, through to the implementation phase and commissioning, you only deal with one point of contact. You have structure and clarity in your data centre project. All participants and all components are precisely coordinated with one another. Every detail contributes to ensure optimum overall performance capability of the system. Rittal The System. Faster better worldwide. We accompany you every step of the way, from analysis, to planning and implementation, through to safeguarding your requirements with our global service. All services from a single source Network enclosures and server racks Power distribution and backup Climate control Monitoring Security solutions Engineering & design Service & support NETWORK ENCLOSURES/ SERVER RACKS POWER DISTRIBUTION/ POWER BACKUP CLIMATE CONTROL 2 RACKS POWER COOLING rittaldatacentre.com.au
5 SECURITY MONITORING SERVICE & SUPPORT MONITORING SECURITY SERVICE & SUPPORT 3 rittaldatacentre.co.nz
6 NETWORK ENCLOSURES & SERVER RACKS Corporate Racks Corporate Racks - TS8 The long term performance of an IT infrastructure is dependent on the coordinated interaction of individual components. With Rittal IT System server enclosures, integration of climate control, power and security solutions is simple. Innovative, modular designs maximise internal space and load bearing capacity while making the addition of new active devices and additional enclosures simple and cost effective. Designed specifi cally for the data centre, the TS8 is a modern enclosure offering strength and stability for virtually any server environment. Its patented 16 fold continuously welded frame delivers 30% more dimensional stability, high load carrying and maximised internal volume. Design Features Robust welded frame structure Front and rear door fully vented; vented surface area > 82% Tool-less adjustment of mounting angles reduces equipment deployment time Vendor neutrality, thanks to infi nite adjustment of mounting angles (L-shaped, front and rear) Cable entry via the roof and base 2-piece side panels Static load capacity of up to 1200 kg Castors and levelling feet on each model Supply Includes 130 tooless quick release type hinges Rear door split type Screen printed RU markings Comfort handles with security lock 3524 E with push button control Material: Mild steel Surface finish: Enclosure frame: Dipcoat primed, powder-coated Enclosure panels: Dipcoat primed, powder-coated Colour: RAL 9005 (Black or RAL 7035 (Grey) Corporate Rack With Side Panels Corporate Rack Without Side Panels RACKS POWER COOLING rittaldatacentre.com.au
7 NETWORK ENCLOSURES & SERVER RACKS High Performance Cooling Racks High Performance Cooling Systems HPC: Material: Mild steel Surface finish: Dipcoat-primed, panels additionally powdercoated, RAL 7035 (Grey). Gland plates and mm (19 ) mounting frame zinc-plated, passivated Supply includes: Enclosure frame with doors and rear panel, roof plate, gland plate, mm (19 ) interior installation, earthing of all panels, levelling feet, fi tted. side panels Model No. With side panels Width mm Height mm Depth mm RU Aluminium glazed front door, sheet steel rear door Roof plate for cable entry, two-piece Levelling feet Base frame with multi-piece gland plate ront and rear L-shaped mounting angles Mounting angles attached to depth stays ront and rear Side panel, screw-fastened, IP Depth-variable slide rail, 1 U, length mm, 80 kg, static, packs of Installation kit for heavy-duty component shelf, depth-variable re nominal dimensions. For absolute dimensions, please refer to the detailed drawing on the Internet. request. MONITORING SECURITY SERVICE & SUPPORT 5 rittaldatacentre.co.nz
8 NETWORK ENCLOSURES & SERVER RACKS Rack Accessories Fixed Shelf Application: Can be used with all 19" cabinets Features: Unique minimised hardware fi xing system Adjustable mounting position Includes mounting hardware and bracketry Finish: RAL7035 (Grey) 19" x 450mm 600 Deep 800 Deep 19" x 600mm 800 Deep 1000 Deep 19" x 740mm 800 Deep 1000 Deep 1200 Deep Sliding Shelf Application: Can be used with all 19" cabinets Features: Adjustable mounting position Includes mounting hardware and bracketry 30kg rating Finish: RAL7035 (Grey) 19" x 450mm 600 Deep 800 Deep 19" x 600mm 800 Deep 1000 Deep 19" x 700mm 800 Deep 1000 Deep 1200 Deep Cantilever Shelf 1RU 180mm Deep RAL 9005 (Black) 2RU 260mm Deep RAL 9005 (Black) 19 Blanking Panels Features: Complete with mounting hardware Colour: RAL7035 (Grey) 1RU 19" Blank Panel 1RU 2RU 19" Blank Panel 2RU 5RU 19" Blank Panel 5RU 9RU 19" Blank Panel 9RU 6 RACKS POWER COOLING rittaldatacentre.com.au
9 NETWORK ENCLOSURES & SERVER RACKS Rack Accessories 1RU Tool-less Blanking Panels Supply includes: 10 blanking panels with integral quick-fastening RAL RAL Modular Tooless Blanking Panel Features: 6RU sheet Snap off feature allows 1 to 6 RU s Tooless 6RU Modular Tooless Blanking Panel Black 6RU Modular Tooless Blanking Panel Grey 1RU & 2RU Cable Management - Ring Panel Can be used with all 19: cabinets Rings can be reorientated All metal construction 1 RU 2 RU 100mm x 37mm 120mm x 80mm Cable Shunting Rings Application: Cable routing Can be mounted to mounting rails, puched sections and cabinet frames. 120mm x 80mm 80mm x 37mm MONITORING SECURITY SERVICE & SUPPORT 7 rittaldatacentre.co.nz
10 NETWORK ENCLOSURES & SERVER RACKS Rack Accessories Cable Tray Material: 1.2 steel construction with vertical slots ideal for hook and clasp cable ties Finish: RAL7035 (Grey) Cable Tray 24RU x 100 wide Cable Tray 42RU x 100 wide Cable Tray 42RU x 300 wide Cable Tray 47RU x 100 wide Cable Tray 47RU x 300 wide Cage Nuts Features: Each fastener kit consists of a M6 cage nut, screw and nylon washer Available in black Fastener Kit x 4 (set) Fastener Kit x 50 (set) Baying Kit Used for the fi xing together of two frames without side panels All fasteners provided Installation and instruction sheets provided Complete Earthing Kit To DIN EN /VDE 0805, Ø 4 mm 2, I max. 40 A. For systemcompatible earthing of all enclosure parts on the enclosure frame according to VDE. The earth conductors are preassembled ready for connection with connectors and cut to the right length. 1 set 8 RACKS POWER COOLING rittaldatacentre.com.au
11 NETWORK ENCLOSURES & SERVER RACKS Rack Accessories Overhead Cable Trough Large capacity cable trough Integrated grounding provisions Unique design allows for power and data cables in one trough with the use of cable claws Cable pass-through provisions Accommodates ladder rack installations in parallel and perpendicular confi gurations Tool-less installation Overhead Cable Trough For laying cable in particularly high packaging densities (high density network nodes), in the fi eld of optical fi bre or copper cabling. Large capacity. A wide range of cable routing, cable clamping, channelling and crosscabling options creates the requirements for maximum port density in the minimum possible space. The individual U-related cable routing makes it possible to dispense with additional cable routing via patch panels within the distributor level, thereby equipping every U with connection points. This increases port density by up to 50%. The removable duct cover, hinged on both sides, facilitates user-friendly access at any time. The cable sections are held back by removable crossbars to protect them against falling out. Mounting is either on mounting rails at the sides, or on mounting angles and mounting frames in the mm (19 ) distributor level. Two ducts may also be secured back-to-back. There is a second, smaller variant available for intensive partial installation. Material: Cable duct: Sheet steel, spray-fi nished Cable routing components: Plastic Front trim panel: Aluminium, spray-fi nished Colour: RAL 7035 Supply includes: Hinged front trim panel Accessories: Cable ties for spare cables 4 Note: When using the duct in conjunction with mm (19 ) mounting frames and TS 8, the inner mounting level in the vicinity of the cable duct is not available. Within the duct, additional cable holders may be attached to accommodate spare cables and for system-compatible cable defl ection. MONITORING SECURITY SERVICE & SUPPORT 9 rittaldatacentre.co.nz
12 POWER DISTRIBUTION/POWER BACKUP Rittal Energy Management Systematic, Holistic Concepts You benefi t from our ideas and innovations. Our complete system offers comprehensive, complete solutions for power distribution and backup. All components are coordinated for maximum benefi ts. The Rittal PSM power distribution system can be adjusted with the system operational. New servers may be installed with little effort (amendments to the infrastructure, coordination of servicing windows or supply of specialist personnel). 5 From the outset, we ensure supply reliability from low-voltage main distributor or the integration of load transfer switches (with up to several hundred KW of output) for connecting mains backup systems such as diesel generators. Our UPS systems are based on double conversion technology, with outstanding effi ciencies of 95%. The Rittal PSM systems save you valuable energy, time and costs. 1 1 Power Modular Concept PMC Power Distribution Rack PDR 3 Power Distribution Module PDM 4 Power System Module PSM 5 Power distribution 10 RACKS POWER COOLING rittaldatacentre.com.au
13 2 3 4 MONITORING SECURITY SERVICE & SUPPORT 11 rittaldatacentre.co.nz
14 POWER DISTRIBUTION/POWER BACKUP Ri4Power System Solutions A New Dimension In Intelligent Power Distribution Rittal offers the entire product spectrum of innovative power distributors up to 5,500 A, from the industrial infeed via IT power distributors, through to the socket in the server rack. The structured Rittal system solution Ri4Power achieves fast, secure and cost-optimised assembly of low-voltage switchgear and IT power distributors in your data centre. The system is based on the broad Rittal product portfolio which provides all the components necessary for highly effi cient, intelligent power distribution. By developing the Ri4Power concept, we have broken new ground to achieve even greater fl exibility with extensive modularity. Ri4Power System Solutions A system based on decades of Rittal experience in the development of power distribution products With innovative busbar technology for maximum modularity and fl exibility of the overall system Outstanding technology combined with state-of-the-art design Compliance with the internationally recognised standards and safety standards goes without saying Within the control and distribution technology for data centres, the innovative Rittal busbar system up to 1,600 A is central to Rittal s low-voltage solutions. With numerous measurement points, Ri4Power records all key data centre performance parameters and makes them available to the network via an integral web server. In this way, the effectiveness of the data centre or PUE (Power Usage Effectiveness) and the effi ciency of individual systems or EER (Energy Effi ciency Ratio) such as refrigeration may be intelligently and selectively optimised. Confi guration of the system and measurement points is automatic thanks to the autodetect feature of the controller. Via SNMP communication, RiZone may be functionally extended to include intelligent power distribution. It is also possible to connect a network-compatible display on site. Rittal has integrated innovative high-current measurement systems into the low-voltage main distributor for intelligent monitoring of data centres to optimise energy demand (energy balance PUE). 12 RACKS POWER COOLING rittaldatacentre.com.au
15 POWER DISTRIBUTION/POWER BACKUP UPS Technology The Ultimate In Availability With Rittal Rittal develops individual UPS concepts on your behalf for the reliable backup of corporate processes where availability is crucial. We will precisely analyse your IT systems to determine which systems are best to support the critical load in a worstcase scenario. Our aim is to ensure maximum availability of the connected infrastructure, maximum energy effi ciency, and exceptional protection for your investment The particular benefi t of Rittal UPS technologies lies in the high operating ratio of the systems. This is synonymous with effi ciency, which in turn is refl ected in the operating costs. After all, with a service life of around 15 years, the energy costs are far more important than the initial investment. With an effi ciency of around 95%, Rittal keeps power loss extremely low, which in itself saves a large amount of energy. Additionally, the low heat loss also means less heat loss inside the enclosure, which in turn saves on energy costs associated with additional climate control. In this way, Rittal UPS systems save twice over with their high effi ciency Efficiency Particularly in the lower load range, a high effi ciency really comes into its own, and also ensures signifi cantly lower heat loss dissipation Capacitive load The capacitive load is increasing in the IT environment. The UPS must be designed accordingly. The PMC 200 can emit constant and full power from 0.9 kw capacitive to 0.8 kw inductive. Rittal PMC UPS Systems For Data Centres Flexibly extendible, rack-mounted modular UPS Choice of redundancy concepts High energy and cost effi ciency, thanks to a high level of effi ciency and maximum supply reliability with double conversion technology Transformerless design, compact systems, high performance density Maximum availability of the entire system No system disturbance in case of unbalanced load (PMC 40/200/800) Various UPS climate control concepts plus network-based UPS and battery monitoring Comprehensive service and maintenance concepts Category UPS classification to EN Rittal UPS 1 VFI: UPS output independent of mains, voltage and frequency variations within the limits to IEC (voltage and frequency independent) 2 VI: UPS output frequency dependent on mains frequency, voltage stabilised (electronic/passive) within the limits for normal operation (voltage independent) 3 VFD: UPS output dependent on mains voltage and frequency variations (voltage and frequency dependent) PMC 800 PMC 200 PMC 120 NX PMC 40 PMC 12 MONITORING SECURITY SERVICE & SUPPORT 13 rittaldatacentre.co.nz
16 POWER DISTRIBUTION/POWER BACKUP UPS Batteries Useful Information UPS Battery Concepts In order to ensure effi cient, maximum availability, we rely on optimised battery concepts. We precisely tailor the required output to the essential bridging times (autonomy/backup time). Our systems use standardised valve-regulated lead acid (VRLA) batteries, which means that spares can be purchased inexpensively worldwide. The batteries are compliant with the EUROBAT 5 standard, and upon request with the EUROBAT 10 standard (service life up to 10 years). Single-phase UPS systems (such as the Rittal PMC 12) generally have integral battery packs that guarantee a bridging time of at least 5 minutes at full load. Optional standardised battery packs may additionally be connected. Important Information For Climate Control Of A UPS Dissipation of heat loss Constant low temperature of the battery packs Battery gas release Application of various climate control scenarios depending on the installation site In a climate controlled environment (temperatures predominantly up to 25 C), vented front and rear doors are suffi cient for outputs of up to 120 kw Use of wall-mounted cooling unit or air/water heat exchanger (such as LCP Smart) with central gas release Service Life Of UPS Batteries In order to achieve a normal service life, batteries need the right ambient conditions. With VRLA batteries, the service life will be signifi cantly reduced with high operating temperatures over long periods. This is due to technological factors, and can only be prevented with sensible climate control. In permanent operation, the operating temperature of the battery packs should not exceed 25 C Other damage may arise as a result of overloading and shortcircuits. Despite the gas-sealed design, dangerous gases may still escape. For this reason, when handling UPS batteries, it is essential to observe the provisions of EN To protect our environment, we will take back batteries sold by us free of charge at the end of their useful life. Rittal guarantees that they will be professionally disposed of in an environmentally friendly manner. 14 RACKS POWER COOLING rittaldatacentre.com.au
17 POWER DISTRIBUTION/POWER BACKUP UPS Monitoring Reliable Protection Of Your UPS Systems There are various options for monitoring Rittal UPS systems. The available fl oating contacts may be used with the PMC. There is optionally a relay card for the PMC 12 which may be inserted into the extension slot and which transmits fault messages for forwarding to the building control system. Detailed information on the operating status of the UPS system, including the charging status of the battery, is sent to a website via a network monitoring card (SNMP card). In the event of an alarm, it is also possible to send a warning . Via this network card, servers may also be shut down individually or in groups according to predefi ned rules before the battery capacity is exhausted. Rittal UPS Monitoring Monitoring via the use of the fl oating contacts provided (PMC 40/PMS 120 NX/PMC 200/PMC 800) or an optional relay card (PMC 12) Or via a network monitoring card (SNMP card) Additional automatic shutdown of servers if necessary via special RCCMD client software. In order for the server to be able to respond to commands from the UPS, a small software tool is required for each server which receives the commands from the UPS and forwards them to the respective operating system. To this end, Rittal uses special shut-down software (RCCMD client software) which may be used for all UPS systems sold by Rittal. UPS web interface MONITORING SECURITY SERVICE & SUPPORT 15 rittaldatacentre.co.nz
18 POWER DISTRIBUTION/POWER BACKUP The Rittal UPS Family Power Module Concept PMC 12 A compact single-phase UPS with scaleable autonomy up to 55 minutes at 100% load produces a broad application spectrum Modules with 1/2/3/6 and 10 kva, single-phase Redundancy n+1 Installation in mm (19 ), 2 U or fl oor-standing enclosure Batteries hot-swap compatible, may be exchanged from the front Scalable to 30kVA PMC 40 Installation in racks with two mm (19 ) levels from a depth of 800 mm. Modules with 10 and 20 kw, 3-phase Redundancy n+1 Safe swap capability with redundancy: Safe module exchange with the system operational, no need to switch to bypass mode PMC 40 (Type 5) TS 8 rack with max. 3 UPS modules and battery pack Compact size, only 800 mm enclosure depth 10/20 kw UPS output modules (3-phase) Up to 40 kw n+1 redundant (max. 60 kw) High operating ratio of 95%, even in part-load operation Expansion/maintenance/module exchange while operational ( safe swap Additional battery rack possible to increase autonomy Double conversion technology VFI-SS-111, output range (scalable) kw PMC 12 PMC 40 PMC 40 type 5 PMC 120 PMC RACKS POWER COOLING rittaldatacentre.com.au
19 POWER DISTRIBUTION/POWER BACKUP PMC 120 TS 8 rack with max. 6 UPS modules in one compact enclosure Compact size, only 800 mm enclosure depth 10/20 kw UPS output modules (3-phase) Up to 100 kw n+1 redundant UPS output (max. 120 kw) High operating ratio of 95%, even in part-load operation Expansion/maintenance/module exchange while operational ( safe swap Batteries in external battery racks support long autonomies PMC 200 Maximum availability, modularity and compact design ensure fl exible, almost unlimited scalability and redundancy The benefi ts to you: Less capital tie-up, inexpensive expansion, and minimal space requirements Modules with 8/12/16/20/24/32/40 kw, 3-phase Redundancy n+1 Installation: Intergrated into the rack Scalability up to 20 modules. This facilitates a maximum output of up to 800 kw or 760 kw n+1 Modular expansion of output and autonomy with the system operational PMC 800 Maximum availability and performance in a modular design The separation of the modules into one power module and one control module is exemplary for this output class. This ensures a high level of service-friendliness and allows precise planning of maintenance work Modules with 64 and 80 kw, 3-phase Redundancy n+1 Installation: Intergrated into the rack Scalability up to 12 modules. This facilitates a maximum output of up to 960 kw or 880 kw n+1 The safe swap technology allows UPS modules (in inverter mode) to be replaced or the UPS extended with the system operational Double conversion technology VFI-SS-111, output range (scalable) kw PMC 800 MONITORING SECURITY SERVICE & SUPPORT 17 rittaldatacentre.co.nz
20 POWER DISTRIBUTION/POWER BACKUP UPS PMC 12 Single-phase, output range 1-12 kva n+1 The UPS is distinguished by the use of double-conversion technology. Double-conversion technology provides the basis for an optimum supply voltage to all connected loads. This makes the Rittal PMC 12 UPS ideally suited for all applications in the IT environment and for other requirements such as automation technology, system control etc. A scalable autonomy of up to 55 minutes at 100% load produces a broad application spectrum. Supply includes: , , Single-phase UPS systems with internal hot-swap compatible batteries, assembly parts, operating manual, software on CD-ROM, USB, RS232 cable and earthing-pin connection cable. Supply includes: , Single-phase UPS systems with assembly parts, operating manual, software on CD-ROM, RS232 cable and connection cable with open cable ends. Autonomy (min.) at 100% load: UPS type In Battery packs supplied state kva 7 min. 28 min. 55 min. 2 kva 7 min. 17 min. 29 min. 3 kva 5 min. 12 min. 20 min. 4.5 kva 9 min. 23 min. 39 min. 6 kva 8 min. 20 min. 33 min. Also required: Country-specifi c connection cables and slide rails are requierd to operate the UPS systens. 18 RACKS POWER COOLING rittaldatacentre.com.au
21 POWER DISTRIBUTION/POWER BACKUP UPS PMC 40 3-phase, output range scalable kw 11 HE 15 HE 18 HE 26 HE Type 1 Type 2 Type 3 Type 4 PMC 40 - compact, rack-independant UPS system (up to 40 kw, 3-phase) This uses double conversion UPS technology according to the highest classifi cation VFI-SS-111, which provides a constant output irrespective of the incoming voltage, coupled with a high overall operating ratio and minimal space requirements. The PMC 40 may be confi gured as a redundant system. As a general principle, it is important to ensure adequate climate control of the rack where the PMC 40 is installed. For installation purposes, the rack must have two mm (19 ) mounting levels and a minimum depth of 800 mm. Depending on the confi guration, mixed population (e.g. with servers) in the same rack is also supported. The PMC 40 (redundant design) has safe swap capabilities. This allows easy, safe module exchange while the system is operational, without having to switch the UPS to bypass mode. Supply includes: A PMC 40 UPS system is comprised of a basic unit for mm (19 ) installation. 1 2 UPS modules and, depending on the version, a maximum of two battery packs per UPS module may be integrated into this basic module. The confi gured complete system comes with basic unit and UPS module(s). Battery packs are supplied separately. MONITORING SECURITY SERVICE & SUPPORT 19 rittaldatacentre.co.nz
22 POWER DISTRIBUTION/POWER BACKUP UPS Power Module Concept UPS Rack With Integral Power Modules And Batteries Thanks to the double conversion technology (VFI-SS-111) the output voltage is independent from the input voltage and frequency Effi cient IGBT power transistor technology achieves a high operating ratio of 95% even in part-load operation Safe swap compatibility with a redundant design, i.e. the module may be exchanged while operational Every UPS module includes power electronics as well as the control unit including display Installation, commissioning and servicing to be carried out by authorised experts only PMC 40 (type 5), 3-phase, output range scalable kw, redundant Dimensions (UPS rack, without base/plinth) width x height x depth mm Packs of 600 x 2000 x x 2000 x 1000 Model No. UPS basic rack Maximum no. of UPS modules 3 Maximum no. of battery packs 4 Maximum UPS output (with 10 kw/20 kw modules) UPS output with n+1 redundancy (with 10 kw/20 kw modules) RS232 (D-Sub 9) and USB interface (configuration and shutdown) 1/1 Fault signal contacts (floating) 5 30/60 kw 20/40 kw Clamping strip input/output (3L+N+PE) max. conductor cross-section 35/50 mm 2 Weight (approximate, incl. batteries and 3 UPS modules) Protection category of UPS system IP 20 Operating temperature range (UPS with batteries, recommended) C Accessibility only required to front (for servicing, maintenance) Distance from wall at rear (due to fan cooling) 740 kg 900 mm 200 mm Model No. PMC kw module (order quantity acc. to output) Model No. PMC kw module (order quantity acc. to output) Model No. PMC 40 battery pack 1 x 4 x 10 batteries, when using 10 kw modules (12 V/7 Ah) prewired (service life 5 years under EUROBAT) Order volume n = 2.3 x Model No. PMC 40 battery pack 1 x 5 x 10 batteries, when using 20 kw modules (12 V/7 Ah) prewired (service life 5 years under EUROBAT) Order volume n = 3.4 x Model No. PMC 40 battery preparation n x 4 x 10 (for export or air freight) Drawers and battery cabling (n = 3.4 without batteries), cable set of 40 Model No. PMC 40 battery preparation n x 5 x 10 (for export or air freight) Drawers and battery cabling (n = 3.4 without batteries), cable set of 50 Accessories UPS monitoring/snmp monitoring card Base/plinth components, front and rear, RAL 7035, 100 mm high Base/plinth components, sides, RAL 7035, 800 mm deep/100 mm high Base/plinth components, sides, RAL 7035, 1000 mm deep/100 mm high Supply includes: UPS system in the TS 8 rack Vented front and rear door Fitted with UPS power modules (depending on confi guration) and batteries The batteries must only be installed at the point of assembly and are delivered separately Note: Only UPS modules with an identical output may be combined. Technical information/ battery configurations: Available on the Internet set set set 1 set 1 set RACKS POWER COOLING rittaldatacentre.com.au
23 POWER DISTRIBUTION/POWER BACKUP UPS Power Module Concept Modular UPS System (up to 120 kw) UPS power modules operate according to the double conversion principle (classifi cation to VFI-SS-111) and have a transformerless design thanks to the high intermediate circuit voltage Effi cient IGBT power transistor technology achieves a high operating ratio of 95% even in part-load operation Safe swap compatibility with a redundant design, i.e. the module may be exchanged while operational Every UPS module includes power electronics as well as the control unit including display Installation, commissioning and servicing to be carried out by authorised experts only Supply includes: UPS system in the TS 8 rack Vented front and rear door Fitted with UPS power modules (depending on confi guration) and batteries Note: Only UPS modules with an identical output may be combined. Battery configurations: Available on the Internet. PMC 120, 3-phase, output range scalable kw Dimensions (UPS rack, without base/plinth) width x height x depth mm Packs of 600 x 2000 x x 2000 x 1000 Maximum no. of UPS modules 6 Maximum UPS output (with 10 kw/20 kw modules) 60/120 kw UPS output with n+1 redundancy (with 10 kw/20 kw modules) 50/100 kw No. of batteries (12 V/28 Ah) per module/battery bank (per 10 kw/20 kw) 40/50 No. of battery banks per battery rack 1), max. 3 No. of batteries (12 V/28 Ah) per battery rack 1), max. 150 Operating ratio (from 50% load) 95% Operating ratio in eco-mode (100% load) 98% RS232 (D-Sub 9) and USB interface (con guration and shutdown) 1/1 Fault signal contacts ( oating) 5 Input (3L+N+PE) conductor cross-section 70/95 mm 2 Output (3L+N+PE) conductor cross-section 70/95 mm 2 Battery connection (3 x M10, joint batteries) conductor cross-section 150 mm 2 Weight (approx., UPS rack with 6 UPS modules) Protection category of UPS system IP 20 Operating temperature range (UPS with batteries, recommended) C Accessibility only required to front (for servicing, maintenance) Distance from wall at rear (due to fan cooling) 285 kg 900 mm 200 mm Base/plinth components, front and rear, RAL 7035, 600 mm wide/100 mm high Base/plinth components, sides, RAL 7035, 800 mm deep/100 mm high Base/plinth components, sides, RAL 7035, 1000 mm deep/100 mm high 1) Batteries not included with the supply of the battery rack. 1 set 1 set 1 set MONITORING SECURITY SERVICE & SUPPORT 21 rittaldatacentre.co.nz
24 POWER DISTRIBUTION/POWER BACKUP UPS Power Modular Concept Rittal PMC 200 ensures optimum availability for critical applications by combining modularity (fl exible, unlimited scalability and redundancy, whereby up to 20 modules may be switched in parallel) with decentralised parallel architecture or DPA (redundant protection without a single point of failure ). The UPS modules are transformerless, genuine online, double-conversion UPSs with static bypass and classifi cation code VFI-SS-111. This modular concept keeps the purchasing and operating costs of redundant solutions exceptionally low. As your performance requirements grow, the UPS grows with you, thanks to its fl exible scalability even in the most confi ned spaces, and with the system operational. The benefits to you: Pay as you grow approach, minimising CAPEX whilst retaining fl exibility for the future Highest levels of availability thanks to short MTTR and long MTBF Rightsizing of UPS provides better effi ciencies for redundancy Safe swap technology enables modules to be removed or added without any downtime High effi ciency even at low loads No single point of failure in overall architecture No de-rating of UPS with leading power factors up to RACKS POWER COOLING rittaldatacentre.com.au
25 POWER DISTRIBUTION/POWER BACKUP UPS PMC phase, output range scalable 8-800kW PMC200 PMC200 Module 10kVA / 8kW PMC200 Module 15kVA / 12kW PMC200 Module 20kVA / 16kW PMC200 Module 25kVA / 20kW PMC200 Module 30kVA / 24kW PMC200 Module 40kVA / 32kW PMC200 Module 45kVA / 40kW Trays and Links for PMC60 Trays and Links for PMC120 Battery Rack (800x2000x1000) max.150 Batt. - common Battery Rack (600x2000x1000) max.120 Batt. - common Battery Rack (600x2000x1000) max.120 Batt. - separate Battery Rack (800x2000x1000) max.150 Batt. - separate A Safe Investment Almost Unlimited Scalability Up to 20 PMC modules may be gradually switched in parallel e.g. in order to supply 800 kw without redundancy or 760 kw n+1 (with 40 kw modules) uninterrupted. May be upgraded with the system operational; no need to switch over to an unprotected network. Trays for Battery Rack / Links (Cables) for Battery Rack / Trays for Battery Rack / Links (Cables) for Battery Rack / Battery string 7Ah (10 Batteries) Battery string 28Ah (10 Batteries) Parallel cable kit for linking 2 PMC200 racks Sub-distributor with 12 3-ph outlets - 16A SNMP Card RCCMD License (Win-NT, UNIX, Novell) - 25 users MONITORING SECURITY SERVICE & SUPPORT 23 rittaldatacentre.co.nz
26 POWER DISTRIBUTION/POWER BACKUP UPS PMC 800 Modular UPS system, three-phase, up to 240 kw per rack. Scalable thanks to parallel switching of several UPS systems (max. 20 modules) up to a total output of 800 kw (760 kw n+1 redundant). Scalability of up to 12 modules, which allows a maximum output of up to 960 kw or 880 kw n+1, higher outputs available on request. The transformerless double conversion architecture ensures a high level of effi ciency. The decentralised parallel architecture (DPA) ensures that no single point of failure infl uences availability of the UPS. The modular architecture allows energy-effi cient confi guration, precisely tailored to requirements. The Safe Swap technology means that the UPS can be replaced (in inverter mode) or extended with the system operational. With a redundant confi guration of the UPS, the load continues to be supplied with current while a module is being replaced. Every UPS module has a separate static bypass and a display, together with the control electronics and a processor. 3-phase, output range scalable kw Minimum fl oor space is required by a rack with three modules (2+1 redundancy) and batteries with autonomy integrated into a single rack. The Rittal PMC 200 allows the integration of up to 5 modules (4+1 redundancy) in one rack. For this confi guration, an additional battery rack is required. The autonomy may be fl exibly adapted to suit your requirements. A safe investment almost unlimited scalability Up to 20 PMC modules may be gradually switched in parallel e.g. in order to supply 800 kw without redundancy or 760 kw n+1 (with 40 kw modules) uninterrupted. May be upgraded with the system operational; no need to switch over to an unprotected network. 24 RACKS POWER COOLING rittaldatacentre.com.au
27 POWER DISTRIBUTION/POWER BACKUP UPS Acessories Mechanical Maintenance Bypass, 2 U for PMC 12 Facilitates uninterrupted removal/maintenance of the UPS. Various designs are required depending on the UPS output category. Connection of the bypass for 1 3 kva UPS models is via a connector (Plug & Play), while the 4.5 and 6 kva UPS variant must be installed by a qualifi ed electrician. It is important to ensure the correct prefuse of the UPS bypass depending on the UPS output used. 1 3 kva (incl. UPS fuse 16 A) kva (incl. UPS fuse 32 A) Sub-distribution mm (19 ) sub-distribution for PMC 12 Outlets 4 x C19 and 2 x 32 A CEE-conforming Single-phase, individually fused. Allows the direct connection of up to 6 pieces of equipment. A qualifi ed electrician must carry out the installation. 1 PMC 12 Plug & Play Sub-distribution for PMC 12, 4.5 and 6 kva This sub-distribution facilitates simple installation and commissioning of the PMC 12 UPS, 4.5 and 6 kva. All that is needed is a single-phase 32 A connection to DIN/EN Sub-distribution Sub-distribution for PMC 40 Allows the direct, fused connection of single- and 3-phase equipment. In this way, up to 4 PSM busbars may be connected directly to the PMC 40 UPS via the relevant connection cables. 1 SNMP card, budget version 1 Single licence 1 SNMP car 1 Parallel hot swap chassis for 2 UPS systems 1 Parallel hot swap chassis for for 3 UPS systems 1 Licence bundle (5 servers) Licence bundle (25 servers) UPS External Wrap Around By-Pass Switches External wrap around Bypass Switches to suit 10 to 200kVA 3-Phase in / 3-Phase out UPS c/w key interlock and 3kVA to 10kVA 1 Phase in / 1 Phase out c/w key interlock. Switches are base mounted in powder coated metal enclosures and are operated via handle mounted on cubicle door. Switch positions are labelled NORMAL - BYPASS & TEST - BYPASS & ISOLATE. Switches are fi tted with a key interlock c/w 1 n/o & 1 n/c auxiliary contacts. Cabling from switch to feed through terminals are provided for both MV & LV system. This alleviates the need for contractors to cable directly to switch termination points. Neutral link & earth terminals are provided, as only active conductors are switched. Labelling of terminals is supplied to installing contractor. Custom switches for any application can be made, please call Rittal to discuss your requirements. MONITORING SECURITY SERVICE & SUPPORT 25 rittaldatacentre.co.nz
28 POWER DISTRIBUTION/POWER BACKUP Power Distribution Rack (PDR) Intelligent Power For Your Data Centre PDR Modular Based on the Rittal TS 8 enclosure platform, the PDR modular IT power distributor supplies up to four IT racks with 3 x 16 A (11 kw) for each Power Distribution Module (PDM) that is inserted. Additional PDMs are easily inserted by trained staff with the system operational. Standardised connection cables permit fast incorporation of new racks into the power supply, without any expert knowledge and no need for any operational interruptions. Customised PDMs, which may be fitted for example with integrated output and differential current measurement or a single-/3-phase 32 A output circuit, provide flexibility. The compact design with an enclosure depth of just 500 mm allows easy integration of the system into the data centre. PDR Flex The Rittal IT current distributor PDR Flex is specifically designed for use in data centres with a high power density. The system is available as a free-standing or wall-mounted distributor, and in both versions is prepared to accommodate installed equipment. All devices in the ABB smissline range (conduction current and residual-current circuit breaker, surge voltage protector etc.) may be used. The ABB smissline locations are wired to the outlet terminals with individual 6 mm² wires to facilitate the use of 32 A circuit-breakers. The straightforward handling means that long interruptions to operation during removal and conversion are now a thing of the past. A 200 mm wide cable chamber behind a vertically hinged trim panel, for example, facilitates easy cable entry from above or below. The system solution PDR Flex is consistently designed for future extendibility. Upon request, it is also possible to integrate an output measurement or network analysis system. 26 RACKS POWER COOLING rittaldatacentre.com.au
29 POWER DISTRIBUTION/POWER BACKUP Horizontal & Vertical Power Rails Features: 10 Amp / 15 Amp All fi xing hardware included Includes 3m lead 20 Amp versions available on request IEC plugs also available on request Colour: RAL 9005 Black Horizontal Features: Mounts to 19 mounting Rails Vertical Features: Mounts to all frame elements Part No. Outlets Type 1 Orientation Dimensions mm L x RU X D Plug Type Special Notes Mounting LPQ06AEEBK 6 X 10 Amp GPO Horizontal 420 x x Amp GPO captive 10 Amp thermal overload 19 LPQ12AEEBK 12 X 10 Amp GPO Horizontal 420 x 88.9 x Amp GPO captive 10 Amp thermal overload 19 LPQ12AEEBKV 12 X 10 Amp GPO Vertical 756 x x 44.5 LPQ21AEEBK 21 X 10 Amp GPO Vertical 1260 x x Amp GPO captive 10 Amp GPO captive 10 Amp thermal overload 10 Amp thermal overload Sliding bracket system Sliding bracket system LPQ06EFEBK 6 X 15 Amp GPO Horizontal 420 x x Amp GPO captive 15 Amp thermal overload 19 LPQ12EFEBK 12 X 15 Amp GPO Horizontal 420 x 88.9 x Amp GPO captive 15 Amp thermal overload 19 LPQ12EFEBKV 12 X 15 Amp GPO Vertical 756 x x Amp GPO captive 15 Amp thermal overload Sliding bracket system LPQ21EFEBK 21 X 15 Amp GPO Vertical 1260 x x Amp GPO captive 15 Amp thermal overload Sliding bracket system Hybrid IEC Power Rails Part No. Outlets Type 1 Outlets Type 2 Orientation Dimensions mm L x RU X D Plug Type Special Notes Mounting LPRHYBRID X 10 Amp C13 IEC 4 X 16 Amp C19 IEC Vertical 1260 x x Amp GPO captive LED indicator Side or top bottom from buttons LPRHYBRID X 10 Amp C13 IEC 4 X 16 Amp C19 IEC Vertical 1260 x x Amp GPO captive LED indicator Side or top bottom from buttons LPRHYBRID X 10 Amp C13 IEC 4 X 16 Amp C19 IEC Vertical 1260 x x Amp GPO captive LED indicator Side or top bottom from buttons MONITORING SECURITY SERVICE & SUPPORT 27 rittaldatacentre.co.nz
30 POWER DISTRIBUTION/POWER BACKUP Monitored and Controlled Power Rails Cabinet PDUs Explained These Rails provide AC and DC Cabinet Power Distribution Units as well as a full line of Fail Safe Transfer Switches. These devices manage everything from basic power distribution and load current monitoring to secure remote access, management and control of the power and network devices within a data centre equipment cabinet Features of these product include LED digital display indicator, IP based remote power management, ability to view power, temperature and humidity levels & receive SNMPbased alarms when conditions exceed defi ned thresholds Product offers ranging from Combine Power Distribution with the ability to monitor network equipment power draws. Each Metered Cabinet Power Distribution Unit s (PDUs) LED digital display indicator provides an accurate, real-time reading of the aggregate power load in amps on each power circuit in the rack. (Metered) Control network access to remote sites and data centre equipment with IP-based remote power management (switched). Data centre managers need solutions such as Sentry Switch POPS (Outlet Power Sensing) units that monitor, track and manage servers and IT equipment and the equipment cabinet infrastructure that houses them. (pops) Use the network interface via Web browser, or receive SNMP-based alarms when conditions exceed defi ned thresholds. (Smart) Smart CDU The Smart Cabinet Distribution Unit (CDU) provides reliable power distribution combined with local and networked power monitoring and environmental montoring* via IP. Use the network interface to view power, temperature and humity levels via Web browser, or receive SNMP based alarms and alerts when conditions exceed defi ned thresholds. Switched CDU The Switched Cabinet Distribution Units (CDU) family combines network confi guration and management with power distribution, power and environmental monitoring. Reboot a single or dual power server with one command and receive SNMP or based alerts when power or environmental conditions exceed thresholds. Assign users specifi c access rights to designated outlets or groups. Sentry: POPS Switched CDU Cabinet Power Distribution Unit with Per Outlet Power Sensing Sentry POPS (Per Outlet Power Sensing) combines all the features and functions of a Switched CDU with the ability to provide power monitoring per an individual outlet/device includes current, voltage, power (kw) apparent power, crest factor and power factor. Using our grouping technology, power information is available per device, groups of devices (application), individual CDU or cabinet. Sentry Power Manager - Manage multiple CDU s across multiple locations Do you have multiple Sentry CDU s in one or more locations that you would like to access from one central point? Would you like one central location where all alarms can be viewed and logged for reporting, or SNMP trap notifi cations? No problem! Our Sentry Power Manager (SPM) product is capable of monitoring and managing mutiple Sentry devices in IP based enterprise networks. SPM provides a global view of all Sentry CDU s with the ability to view devices based on their temperature, humidity, current and device status. Besides managing and monitoring all alarm conditions, this information can also be used to provide reporting and trending information for display within SPM or integrated with your existing Building Management System (BMS). 28 RACKS POWER COOLING rittaldatacentre.com.au
31 POWER DISTRIBUTION/POWER BACKUP Monitored and Controlled Power Rails Smart Part No. CS-16VE-P32M CS-24VE-P32MA CL-16VE-P32M CL-24VE-P32MA Web addressable monitoring, local current meter, Branch Circuit Protection on various models, temperature/humidity support Smart CDU, 0U, 16 x IEC C13 Outlets, LED amp meter, 230V 32A input w/ IEC A connector & cord, 10 ft (3m) w/ 2 x Temp/Humid Capable, with retractable fuses Smart CDU, 0U, 18 x IEC C13 Outlets, 6 x IEC C19 Outlets, 3 x LED amp meters, 230V input w/ IEC A connector and cord 10ft (3m), 2 x Temp/Humid Capable, with retractable fuses Smart CDU (Expansion Unit), 0U, 16 x IEC C13 Outlets, LED amp, 230V meter 32A input w/ IEC A connector & cord, 10 (3m), with retractable fuses Smart CDU (Expansion Unit), 0U, 18 x IEC C13 Outlets, 6 x IEC C19 Outlets, 3 x LED amp meters, 230V input w/ IEC A connector and cord 10ft (3m), with retractable fuses Switched Part No. CW-16VE-P32M CW-24VEK311A1 CX-16VE-P32M CX-24VEK311A1 Switched POPS Part No. CWG-24VEK311A1 CXG-24VEK311A1 Sentry Power Manager (SPM) Part No. SPM-APP SPM-25 SPM-50 SPM-100 SPM1-25 SPM1-50 SPM1-100 Web addressable monitoring and control, individual outlet reboot, local current meter and Branch Circuit Protection on various models, temperature/humidity support Switched CDU, 0U, 16 x IEC C13 Outlets, LED amp meter, 230V 32A input w/ IEC connector & cord, 10ft (3m), 2 x Temp/Humid Capable, with retractable fuses Switched CDU, 0U, 18 x IEC C13 Outlets and 6 x IEC C19 Outlets, 3 x LED Amp Meters, 230V 32A Input w/ IEC Connector, Bottom/Front Cord Entry, 3m (10_x0019_) Cord, 2 x Temp/Humid Capable, with Retractable Fuses Switched CDU (Expansion Unit), 0U, 16 x IEC C13 Outlets, LED amp meter, 230V 32A input w/ IEC connector & cord, 10ft (3m), with retractable fuses Switched CDU (Expansion Unit), 0U, 18 x IEC C13 Outlets and 6 x IEC C19 Outlets, 3 x LED Amp Meters, 230V 32A Input w/ IEC Connector, Bottom/Front Cord Entry, 3m (10 ) Cord, with Retractable Fuses Switched POPS (Per Outlet Power Sensing) provide power monitoring at the outlet level, Web addressable monitoring and control, individual outlet reboot, local current meter and Branch Circuit Protection on various models, temperature/humidity support Switched POPS CDU, Per Outlet Power Sensing, 0U, 18 x IEC C13, 6 x IEC C19, 3 x LED Amp Meters, 230V 32A w/ IEC Connector and Cord, Bottom/Front Entry, 3m (10ft) Cord, 2 x Temp/Humid Capable, w/ Retractable Fuses Switched POPS CDU (Expansion Unit), Per Outlet Power Sensing, 0U, 18 x IEC C13, 6 x IEC C19, 3 x LED Amp Meters, 230V 32A w/ IEC Connector and Cord, Bottom/Front Entry, 3m (10ft) Cord, w/ Retractable Fuses Monitor and manage multiple CDUs in one or multiple locations Sentry Power Manager - Hardware appliance. Required for SPM node license(s). Hardware includes 2-year warranty. Sentry Power Manager - 25 node license, requires support contract Sentry Power Manager - 50 node license, requires support contract Sentry Power Manager node license, requires support contract Sentry Power Manager 25 Node - 1 year service contract, S/W updates Sentry Power Manager 50 Node - 1 year service contract, S/W updates Sentry Power Manager 100 Node - 1 year service contract, S/W updates Environmental Monitors Part No. EMTH-1-1 Combination Temperature & Humidity Probe, 10 ft (3 m) EMWS-1-1 Water Sense Probe - 15 feet (4.5 m) MONITORING SECURITY SERVICE & SUPPORT 29 rittaldatacentre.co.nz
32 POWER DISTRIBUTION/POWER BACKUP Power System Module (PSM) Power Distribution Directly In The IT Rack Modern, powerful servers such as blade server systems have an increasingly high energy demand. This necessitates corresponding power distribution components directly in the IT rack. To this end, Rittal has developed the intelligent Power System Module (PSM) which intelligently meets current demands for power management and performance data logging at server level. Requirements such as operational reliability, redundancy and extendibility with the system operational have been consistently implemented. As a bar system for IT racks, our PSM has complete contact hazard protection. The outputs are designed as plug-in modules available for the various pin patterns and application scenarios. The bar system with three-phase circuits has a redundant design. The Rittal Power System Module A wide range of PSM bars with complete contact hazard protection in a compact, patented design Flexibly extendible with the system operational MID-conforming for consumption calculations, and with a VDE-tested design Repurchase guarantee for standard systems Also with switching function for the outputs, current and output measurement or optical load display This means that outputs of up to 22 kw (2 x 3 x 16 A) can be distributed across up to seven module slots via the PSM bar. There are also variants with 3 x 32 A or 1 x 32 A infeed. Special versions (PSM+) have four three-phase infeeds which doubles the output. Upon request, several PSM bars may be integrated into one IT rack, facilitating the physical separation of A and B supplies in the rack. Other application options include the deactivation of individual racks or components in the event of alarm messages this may be utilised via the active Rittal PSMs with switching function and current measurement at server level. 30 RACKS POWER COOLING rittaldatacentre.com.au
33 POWER DISTRIBUTION/POWER BACKUP Power System Module (PSM) PSM busbar With Fixed Infeed/RCD Busbar with Residual Current protective Device (RCD). The busbar is protected against inadmissibly high touch voltages by two RCDs with a rated differential current of 30 ma. One RCD protects 3 slots on the bar. Additionally, there are two 16 A miniature circuit-breakers integrated into the bar. Infeed is via a 32 A CE connector. Supply includes: Busbar with 3 m fi xed connection cable, instructions, assembly parts. Also required: Plug-in module PSM, Model Number For enclosure height mm Power Supply Maximum No. of modules x 32A 6 PSM Plug-in Module With Integral RCD PSM module with integral RCD. The rated differential current of the RCD is 30 ma. The module occupies 2 module slots on the PSM bar. Model Number Plug-in module Number of sockets EC C13 8 x 13C Plug-modules active PSM with individual current measurement (IP-compatible in conjunction with CMC-TC) Module with 8/4 1) slots, individually switchable or logging of individual currents per outgoing slot (C13/C19) via the Rittal CMC-TC. These active, switchable modules each occupy 2 slots in the PSM bar, and therefore up to 3 x 2 IEC320 C13 outlet modules may be installed in a PSM busbar for 2000 mm (1200 mm) high racks. Combined population of different modules is also supported. A maximum of 16 modules may be administered via one IP address. Material: Aluminium section with black plastic cover Supply includes: PSM plug-in module, instructions, bus cable. Note: Operating the module without CMC-TC (local current display in the rack) For operation of the socket strip, power pack DK and a mains cable (country-specifi c) is required. Up to 4 modules may be operated with one power pack. However, confi guration of the individual limits is only possible via the CMC-TC. A PSM busbar is required to operate. Model Number Plug-in module Number of slots IEC C IEC C ) There are additionally 2 x IEC C13 slots (IEC 320 connection) available. MONITORING SECURITY SERVICE & SUPPORT 31 rittaldatacentre.co.nz
34 POWER DISTRIBUTION/POWER BACKUP Power System Module (PSM) PSM/PCU modules in conjunction with the CMC-TC Common features: 2-digit local LED 7-segment current display. Individual current measurement per slot with limit confi guration via CMC-TC web interface. LED colour code for fast load assessment per module, and (new): per slot. SNMP switching option via the network. Up to 16 modules via a joint web interface under one IP address (up to 4 modules of the same type per port). Measuring and monitoring of the current per module and outgoing slot. Limits (range limits, signalling via coloured LED) may be freely confi gured. The 8/4 1 ) individual slots of the module may be switched separately in conjunction with the CMC-TC. May also be linked to other CMC-TC alarm messages. Alarm messages are additionally indicated byfl ashing LEDs. Up to 16 modules may be administered with one CMC-TC system via a shared IP address. Also required: CMC-TC Processing Unit II, DK wide-range power pack (sec. 24 V DC), DK U mounting unit, DK Connection cable (Cat 5), DK CMC-TC programming cable, DK Connection cable (DE) 230 V AC, DK ) There are additionally 2 x IEC C13 slots (IEC 320 connection) available per module. Rittal Power Control Unit with individual current measurement (PCU, IP-compatible in conjunction with CMC-TC) Module with 8/4 1 slots, individually switchable or logging of individual currents per outgoing slot (C13/C19) via the Rittal CMC-TC. This module may be mounted both within the mm (19 ) level and on the enclosure frame (zero-u). Material: Aluminium section with black plastic cover Supply includes: PCU mm (19 ) module, bus cable, instructions, assembly parts for mm (19 ) installation, connector. Note: Operating the PCU without CMC-TC (local current display in the rack) For operation of the socket strip, power pack DK and a mains cable (country-specifi c) are required. Up to 4 modules may be operated with one power pack. However, confi guration of the individual limits is only possible via the CMC-TC. Model Number Plug-in module Number of slots IEC C IEC C ) There are additionally 2 x IEC C13 slots (IEC 320 connection) available per module. 32 RACKS POWER COOLING rittaldatacentre.com.au
35 POWER DISTRIBUTION/POWER BACKUP Power System Module (PSM) PSM Busbar With Fixed Infeed, 3-phase Busbar with fi xed connection cable for strain relief. The existing DIN screw fastening prevents the cable from being pulled out accidentally. Connection is made using a 3 m connection cable with open cable ends. Supply includes: Busbar with fi xed connection cable, assembly instructions, assembly parts. Also required: PSM plug-in modules, see IT Catalogue, page Model Number For enclosure height mm Power Supply Maximum no. of modules x 16A x 3 x 16A 7 PSM Busbar For 47 U rack, 3-phase PSM busbar in special versions for 47 U racks. The 2100 mm high busbar offers 8 slots for PSM modules. Technical specifications: 3-phase infeed construction with a maximum current of 3 x 16 A A redundant three-phase infeed with 3 x 16 A may also be added The redundant circuit is completely separate from the 3 phases of the support rail Supply includes: Busbar, assembly instructions, assembly parts. Without cable. Also required: Connection cable, PSM plug-in modules, see IT Catalogue, page Model Number For enclosure height mm Power Supply Maximum no. of modules x 3 x 16A 8 PSM Busbar With Measurement Single-phase, 32 A Busbar with integral output measurement to display and monitor the entire connected current of the PSM bar. The display is local. The bar is remotely administerable and confi gurable in conjunction with the CMC-TC system. The following active functions are provided: Local display Measurement and monitoring of the current and voltage. Adjustable limits. Measurement range 0 16 A/0 250 V Alarm notifi cations via a fl ashing display Remote administration of the bar supported (in conjunction with the CMC-TC) Supply includes: Busbar with fi xed connection cable,with CE connector (32 A), instructions, assembly parts. Note: In stand-alone mode without CMC-TC, a separate power pack DK with connection cables is required. Also required: PSM plug-in modules, see IT Catalogue, page , CMC-TC system, see IT Catalogue, from page 153. Model Number For enclosure height mm Power Supply Maximum no. of modules x 32A 6 MONITORING SECURITY SERVICE & SUPPORT 33 rittaldatacentre.co.nz
36 POWER DISTRIBUTION/POWER BACKUP Battery Monitoring If you re operating mission critical systems and relying on the protection of a UPS and battery bank, then it makes sense to have battery monitoring. It s about peace of mind knowing that the batteries are healthy and being constantly monitored. Knowing that everything has been done, that can be done, to protect your enterprise from the consequences of a power failure. Rittal Battery Monitoring Features 24/7 alarm notifi cation. Automatic capture and recording of data during fl oat, charge, discharge & idle. Compatible with fl oat & intermittent charging Rapid voltage sampling - all batteries simultaneously every 4 seconds. Built in intelligence - battery state recognition & self calibration for reliable impedance User defi ned alarm limits On-board memory Sealed, vented, Ni-Cd batteries Flexible to suit battery model & application Designed to allow IEEE/IEC best practice Link Battery Management Software Proactive management tool Permanent connection to multiple sites Real time battery status Alarm & activity log with on-screen pop-ups and alerts Live discharge display Automated data management with RDBMS storage Battery history database for life trending Point & click report generation Data Presentation Is The Key For Efficient Management A single Rittal system can monitor up to 1,280 batteries. Connecting multiple systems via Rittal Link battery management software gives visibility to an unlimited number of batteries from a single desk. Rittal offers: WAN/LAN integration for remote monitoring via Link software RS 232 connection for local battery service & diagnosis SNMP or Modbus interface to Building Management Systems Dry contacts for alarm output Ensure that you can see and understand what is happening in your battery room. 34 RACKS POWER COOLING rittaldatacentre.com.au
37 MONITORING SECURITY SERVICE & SUPPORT 35 rittaldatacentre.co.nz
38 CLIMATE CONTROL High-End Solutions For The Lowest Energy Costs On average, 50% of the energy costs in data centres are attributable to the infrastructure. For this reason, Rittal focuses particular attention on energy-effi cient cooling components and cross-system control concepts % power distribution and backup 3% lighting etc. 50% servers 6 37% cooling Rittal aisle containment 2 CRAC systems 3 LCP Plus/Smart 4 IT chillers 5 Free cooling 6 Pipework 7 Raised fl oor for cold air supply 36 RACKS POWER COOLING rittaldatacentre.com.au
39 MONITORING SECURITY SERVICE & SUPPORT 37 rittaldatacentre.co.nz
40 CLIMATE CONTROL Rittal Liquid Cooling Package LCP Climate control of your data centre is becoming ever more important in terms of availability and energy costs. The Rittal Liquid Cooling concepts ensure precise, problem free heat loss dissipation of up to 60 kw per rack RACKS POWER COOLING rittaldatacentre.com.au
41 CLIMATE CONTROL 4 1 Rack climate control CW via chiller 2 Rack climate control CW via external condenser 3 Bayed climate control CW via chiller 4 Bayed climate control CW via external condenser CW = Chilled Water DX = Direct Expansion MONITORING SECURITY SERVICE & SUPPORT 39 rittaldatacentre.co.nz
42 CLIMATE CONTROL Best Performance In All Categories Rack Climate Control The LCP for rack climate control is designed for siting within a bayed enclosure suite. The cold air is expelled sideways on the front of the servers, and warm air is drawn back in at the rear. The LCP for rack climate control is ideal for maximum cooling performance and maximum fail-safeness, thanks to redundancy of all key components. A large-scale high-capacity air/water heat exchanger, designed as the rear door of the server enclosure, ensures that heated waste air from the servers is cooled down to server intake air level. This is achieved extremely energy-efficiently, because no electrical power is required for fans. High inlet temperatures above the dew point improve energy efficiency still further. Technology CW = Chilled Water DX = Direct Expansion CW CWT3 DX CW T3+ = for Tier 3 and 4 Output kw 10, 20, 30, 40, 50, Cooling medium Water Water Coolant Water Auto-load balancing Auto-recovery 40 RACKS POWER COOLING rittaldatacentre.com.au
43 CLIMATE CONTROL The Benefits To You: Maximum energy effi ciency by positioning the EC fan technology in the cold air zone with a considerably extended service life Minimal pressure loss at the air end, which in turn minimises the power consumption of the fans Optimum adaptability thanks to dynamic, continuous control of the cold water volume fl ow. By using high water inlet temperatures, the proportion of indirect free cooling is increased, which in turn reduces operating costs. Row Based Cooling The LCP for bayed climate control is designed for siting within a bayed enclosure suite. The hot air is drawn in from the room or hot aisle at the rear of the device and expelled at the front into the cold aisle after cooling. The LCP for inline bayed climate control achieves maximum performance and efficiency in conjunction with Rittal cold aisle containment. Technology CW = Chilled Water DX = Direct Expansion CW DX T3+ = for Tier 3 and 4 Output kw 10, 20, 30, 40, 50, Cooling medium Water Coolant Auto-load balancing Auto-recovery MONITORING SECURITY SERVICE & SUPPORT 41 rittaldatacentre.co.nz
44 CLIMATE CONTROL Liquid Cooling Packages Benefits: Maximum energy effi ciency thanks to EC fan technology and IT-based control Minimal pressure loss at the air end, which in turn minimises the power consumption of the fans Optimum adaptability thanks to dynamic, continuous control of the cold water volume fl ow By using high water inlet temperatures, the proportion of indirect free cooling is increased, which in turn reduces operating costs Thanks to six modular, box-type plug-in fan units, the cooling output can be adapted to actual requirements The box-type plug-in fan units are confi gurable as n+1 redundancy Standard 3-phase connection for electrical redundancy With redundant temperature sensor integrated at the air end as standard The separation of cooling and rack prevents water from penetrating the server enclosure. Up to 60 kw cooling output on a footprint of just 0.36 m² The low weight means a minimal load area Touchscreen display may be retrofi tted Monitoring: Monitoring of all system-relevant parameters such as: Server air intake temperature Server waste air temperature Water inlet/return temperature Water fl ow Cooling output Fan speed Leakage Optional sensors Direct connection of the unit via SNMP/Ethernet Integration into RiZone Application and mode of operation: The LCP draws in the air at the sides at the rear of the server enclosures, cools it using highperformance compact impellers and blows the cooled air back into the front part of the server enclosure at the sides. Colour: RAL 7035 (Grey) Protection category: IP 40 to EN TopTherm LCP Rack CW And DX Design CW CW CW DX Cooling medium Water (for specifications see Internet) Refrigerant R410A Model No. SK Rated operating voltage V, Hz 230, 1~, 50/60 400, 3~, 50/60 230, 1~, 50/60 400, 3~, 50/60 230, 1~, 50/60 400, 3~, 50/60 230, 1~, 50/60 400, 3~, 50/60 Dimensions mm W x H x D 300 x 2000 x x 2000 x x 2000 x x 2000 x 1000 Usable U Useful cooling output Up to 30 kw Up to 30 kw Up to 60 kw Up to 10 kw Duty cycle Electrical connection 100% Connection cable Linear fan control Temperature control Two-way control valve Fans may be exchanged with the system operational EC fan Accessories Packs of Condenser unit Fan module Touchscreen display, coloured Connection hose, top Connection hose, bottom RACKS POWER COOLING rittaldatacentre.com.au
45 CLIMATE CONTROL Power LCP T3+ Cooling A B Redundant power supply TopTherm LCP T3 + CW A B Redundant cooling medium supply Benefits: Error-tolerant, effi cient cooling of server racks with high thermal loads Fully redundant Two active cooling circuits and two switchable power circuits ensure optimum fail-safeness The built-in controllers are capable of adapting all device parameters automatically to preserve the required climate conditions A separate decentralised intelligence which automatically recognises emergency situations and responds appropriately with the autoload balancing and autorecovery functions Interfaces which facilitate user-friendly operation and monitoring via the network or BSM systems Optional: Fully integrated fi re detection and extinguisher system Automatic server enclosure door opening Various sensors Application and mode of operation: The LCP draws in the air at the sides at the rear of the server enclosures, cools it using high performance compact impellers, and blows the cooled air back into the front part of the server enclosures at the sides. Colour: RAL 7035 (Grey) Protection category: IP 40 to EN Cooling medium Water (for specifications see Internet) Model No. SK Rated operating voltage V, Hz 230, 1~, 50/60 400, 3~, 50/60 Dimensions mm W x H x D 300 x 2000 x 1200 Usable U 42 Useful cooling output, redundant Up to 25 kw Duty cycle 100% Electrical connection Temperature control Fans may be exchanged with the system operational EC fan Auto-load balancing Auto-recovery Accessories Fan module Touchscreen display, coloured Connection hose, top Connection hose, bottom Packs of C19/C20 Linear fan control Two-way control valve MONITORING SECURITY SERVICE & SUPPORT 43 rittaldatacentre.co.nz
46 CLIMATE CONTROL Liquid Cooling Packages Benefits: Maximum energy effi ciency thanks to EC fan technology and IT-based control Minimal pressure loss at the air end, which in turn minimises the power consumption of the fans Optimum adaptability thanks to dynamic, continuous control of the cold water volume fl ow By using high water inlet temperatures, the proportion of indirect free cooling is increased, which in turn reduces operating costs. Thanks to six modular, box-type plug-in fan units, the cooling output can be adapted to actual requirements The box-type plug-in fan units are confi gurable as n+1 redundancy Standard 3-phase connection for electrical redundancy With redundant temperature sensor integrated at the air end as standard The separation of cooling and rack prevents water from penetrating the server enclosure Up to 60 kw cooling output on a footprint of just 0.36 m² The low weight means a minimal load area Touchscreen display may be retrofi tted TopTherm LCP Inline CW And DX Design CW CW DX Water (for speci cations see Internet) Refrigerant R410A Rated operating voltage V, Hz 230, 1~, 50/60 400, 3~, 50/60 Monitoring: Monitoring of all system-relevant parameters such as: Server air intake temperature Server waste air temperature Water inlet/return temperature Water fl ow Cooling output Fan speed Leakage Optional sensors Direct connection of the unit via SNMP/Ethernet Integration into RiZone Application and mode of operation: The LCP is designed for siting within a bayed enclosure suite. The hot air is drawn in from the room or hot aisle at the rear of the device and expelled at the front into the cold aisle after cooling. The LCP achieves maximum performance and effi ciency in conjunction with Rittal cold aisle containment. With this product, a raised fl oor is not necessary. Colour: RAL 7035 (Grey) Protection category: IP 40 to EN , 1~, 50/60 400, 3~, 50/60 230, 1~, 50/60 400, 3~, 50/60 Dimensions mm W x H x D 300 x 2000 x x 2000 x x 2000 x 1200 Usable U Duty cycle Electrical connection 100% Connection cable Linear fan control Temperature control Two-way control valve Fans may be exchanged with the system operational EC fan Packs of Condenser unit (QX) Front cover Fan module Touchscreen display, coloured Connection hose, top Connection hose, bottom RACKS POWER COOLING rittaldatacentre.com.au
47 CLIMATE CONTROL Benefits: High cooling output of 20 kw in a minimal space Easily exchanged for the standard rear door of the server enclosure Easy retrofi tting A door opening angle of 120 allows rear access to the server enclosure and makes assembly and confi guration inside the enclosure easier The LCP does not require its own fan, and therefore does not need an integrated control Maximum energy effi ciency, as there is no electrical power consumption whatsoever Application and mode of operation: Air/water heat exchanger mechanically integrated into a rear door for server enclosures. The mm (19 ) equipment built into the server enclosure must have suitable airfl ow capabilities in order to route the heated waste air through the heat exchanger rear door. The waste air is cooled down to room temperature. The heat energy absorbed by the water is transported to the external cold water supply, where it is cooled back down to the required inlet temperature. Colour: RAL 7035 (Grey) Approvals: Available on the Internet. TopTherm LCP Passive CW Model No. SK Dimensions mm W x H x D 600 x 2000 x 170 Usable U 42 Useful cooling output Up to 20 kw MONITORING SECURITY SERVICE & SUPPORT 45 rittaldatacentre.co.nz
48 CLIMATE CONTROL Aisle Containment Cold Air Precisely Where It Is Needed In server rooms that have not been designed as data centres, the permanent mixing of cooled and heated air often leads to cooling defi cits. Hot spots make the IT equipment s work more diffi cult. In order to effi ciently ensure the necessary cooling here, Rittal has developed three cooling variants for aisle containment. Two solutions use containment of the cold aisle. The LCP Inline guides the cooled air directly to the cold aisle at the front, and the CRAC system to the raised fl oor, so that the cooled air is fed to the cold aisle via perforated raised fl oor plates. The third solution operates according to the principle of enclosing the hot aisle. The LCP Inline extracts the hot air directly at the point where it is created. The cooling performance of the cooling units is utilised to optimum effect, and the overall effi ciency of the system increases signifi cantly. Rittal Aisle Containment Intake air (cold) and waste air (hot) are unable to mix. It is possible to operate at a higher temperature level throughout the entire system. The CRAC units operate at maximum effi ciency, thanks to the greater temperature difference between the cold and hot air. Modular, scalable and upgradable. Simple arrangement. An inexpensive solution for the optimum cooling of existing data centres. Rittal Aisle Containment (Cold Aisle) With raised floor Use of inexpensive standard CRAC cooling units sited outside of the server area Even with low room heights, the raised fl oor height is maximised for cooling air supply without fl ow losses Undisturbed and uniform air fl ow distribution of cooling air in the cold aisle guarantees high effi ciency Favourable working conditions in the cold aisle due to low temperature, fl ow and noise load conditions Hardware racks not connected to the enclosure do not impair the cooling effi ciency of the cold aisle Rittal Aisle Containment (Cold Aisle) Without raised floor Direct connection of the liquid cooling packages to an external cold water supply Simple laying of pipework in the rack base/plinth Homogeneous distribution of cooling air in the cold aisle guarantees a high level of effi ciency Favourable working conditions in the cold aisle due to low temperature, fl ow and noise load conditions Hardware racks not connected to the containment system do not impair cooling effi ciency via the cold aisle Room heights play only a minimal role Rittal Aisle Containment (Hot Aisle) Without raised floor Simple assembly using the existing components of Rittal aisle containment Direct connection of the Liquid Cooling Packages (LCP Inline) to an external cold water supply Simple laying of pipework in the rack base/plinth Suitable for use with high heat losses Room-neutral dissipation of the heat loss 46 RACKS POWER COOLING rittaldatacentre.com.au
49 CLIMATE CONTROL CRAC Systems Fresh power for data centres and server rooms. Modern IT climate control technology ensures optimum thermal conditions in rooms exposed to high loads, such as data centres and server rooms. The main aim here is to ensure constant temperatures and precise humidity levels. Continuous-operation designs and redundant systems ensure that all key functions are maintained. Rittal CRAC systems dissipate waste heat from the IT equipment on demand, ensuring that the overall system operates in the most energy-saving way possible. The fan is positioned inside the raised fl oor. This provides for optimal air distribution in the raised fl oor and also reduces energy consumption by minimising pressure defl ection losses. The integration of a heat exchanger with a larger surface area also enables potential savings in chilled water generation by utilising higher water inlet temperatures. Model No. Width Height Depth Useful Cooling Output 1 kw Operating Voltage V/Hz Cooling Medium Volumetric Airflow at an External Pressure Loss of 20Pa m 3 /h /500 water /500 water /500 water /500 water /500 Refrigerant R407c /500 Refrigerant R407c /500 Refrigerant R407c /500 Refrigerant R407c ) Output fi gures less heat from the fans. CW: 26 C/45% air inlet and 10 C/15 C water temperatures DX: 26 C/45% air inlet and 50 C condensation temperature 2) Other media available on request. Other options available on request. We reserve the right to make technical modifi cations. Benefits: The unit is available in a broad output range, and for a variety of cooling media. The unit supports optimum integration of both hardware and software. Optimum energy and space effi ciency thanks to intelligent design features, such as the slanted heat exchanger and base integrated fan. Frame based on the popular TS 8 system. Functional principle: The CRAC system draws warm waste air from the top of your data centre, cools it with either water or refrigerant in a closed heat exchanger, and blows the cooled, fi ltered supply air into the unit s fl oor with overpressure. Equipment: User-friendly, high-quality control with an extensive range of functions and connectivity. Space-saving, readily accessible, high-effi ciency fan. Flow and energy-optimised special heat exchanger with a generous safety factor. The standard scope of the system includes the enclosure and the supporting structure for integration into a raised fl oor, as well as an autonomous controller with graphic display and the integrated fi lters. Pre-defi ned component lists permit the project-specifi c integration of additional options such as a humidifi er, an electric heater, diverse interfaces (BACnet, RS485) etc. MONITORING SECURITY SERVICE & SUPPORT 47 rittaldatacentre.co.nz
50 CLIMATE CONTROL IT Chillers Exceptionally Efficient IT Cooling The Rittal IT chiller in conjunction with indirect free cooling supplies media for exceptionally energy and cost-effi cient IT cooling. The system is specially designed for supplying critical IT applications cooled via LCP, air/water heat exchangers or CRAC systems. In this atmospherically sealed system, security options such as redundant, speed-regulated pumps, compressors, emergency cooling or buffer stores ensure optimum operational reliability and fail-safeness. Alongside optional heat recovery from the system, the connection to the Rittal free cooling recooling systems ensures exceptionally energy-effi cient operation. Free cooling uses cold ambient air for cooling, reduces operating costs by up to 80%, extends the service life of components, and increases operational reliability. If the free cooling performance is insuffi cient, the IT chiller will cut in. IT Chiller Redundant pumps, speed-regulated Redundant scroll compactor Intelligent control concept Interfaces: SNMP, BACnet Integral or separate free coolers (optional) Integral automatic bypass valve Flow monitor Minimisation of operating costs thanks to high water inlet temperatures for LCP and CRAC operation High COP (coeffi cient of performance) Integration into RiZone kw units 48 RACKS POWER COOLING rittaldatacentre.com.au
51 CLIMATE CONTROL Alternative Cooling New Forms Of IT Cooling Rittal is consistently seeking new technological approaches to make data centre operation even more effi cient and eco-friendly. We are intensively involved in the new forms of IT cooling, and we monitor trends, and evaluate new technologies. Anything which is eco-friendly and helps to cut energy costs is incorporated into our product development. Direct Free Cooling (DFC) Rittal climate control systems with DFC cool directly with cold external air at low external temperatures. An air valve system regulates the various airfl ows and adds waste air from the data centre to achieve the required inlet temperature. Kyoto Cooling (KC) KC refers to the indirect cooling of a data centre with external air. At its heart is a rotary heat exchanger which connects the external and internal air zones energetically but physically separates the airfl ows. Goethermal Energy With geothermal energy, the cooling medium heated in the data centre is conducted into the earth via probes and cooled so that it can be reused directly for cooling purposes. Absorption Cooling With this technology, the waste heat e.g. from solar thermal energy plants or combined heat and power (CHP) units is used to generate cooling. Efficient Control Concepts T control, P control The Rittal control concept ensures the cost-effective operation of the EC fans used in the cooling units. By variably adapting the volume of air required depending on the servers, the fans operate at maximum effectiveness and effi ciency. Kyoto cooling Direct free cooling MONITORING SECURITY SERVICE & SUPPORT 49 rittaldatacentre.co.nz
52 MONITORING CMC III Monitoring System - A Solution For Every Task 50 RACKS POWER COOLING rittaldatacentre.com.au
53 MONITORING IT security is now inextricably linked with the Computer Multi Control (CMC) monitoring system it has become fi rmly established as a permanent feature of physical IT security, allowing modern IT infrastructures to be operated securely, while at the same time ensuring optimum performance. The CMC III monitoring system sets new standards with regard to simple assembly and confi guration, reduced system complexity, and cost-effectiveness. In order to be able to cover the wide range of potential applications in IT and industry, the CMC III monitoring system is available in two variants: CMC III Processing Unit Compact The compact monitoring solution for applications in industry and building monitoring or for smaller IT projects with up to four additional CAN-Bus monitoring components. CMC III Processing Unit The powerful, modularly extendible monitoring solution for demanding IT and industrial environments with the option of connecting up to 32 additional monitoring components. The benefits to you with both variants: Minimal cabling work thanks to bus technology Temperature and access sensor, digital inputs and relay output already integrated into the base unit Sensors may be connected directly Power supply either redundant via two PSUs, directly via 24 V DC with industrial applications, or with Power over Ethernet (PoE) Integral OPC server allows direct communication with the control room (BMS or SCADA system) Fail-safeness, thanks to CAN-Bus technology. Even if the processing unit should fail, the sensors can still communicate with one another autonomously. MONITORING SECURITY SERVICE & SUPPORT 51 rittaldatacentre.co.nz
54 MONITORING CMC III Monitoring System CMC III Processing Unit 1 CMC III Processing Unit 2 Power supply 3 Redundant power supply 4 CMC III 1/0 Unit 5 CMC III Power Unit 6 CMC III CAN-Bus Unit 7 Up to 16 CAN-Bus systems may be connected 8 CMC III sensors for direct connection 9 CMC III CAN-Bus sensor for connection of CMC II sensors 10 CMC III CAN-Bus Access 11 Up to 16 CAN-Bus systems may be connected CMC II Processing Unit Compact 13 Power supply 14 Redundant power supply 15 CMC III sensors for direct connection 16 CMC III CAN-Bus sensor for connection of CMC II sensors 17 CMC III CAN-Bus Access 18 Up to four CAN-Bus systems may be connected 52 RACKS POWER COOLING rittaldatacentre.com.au
55 MONITORING CMC II Processing Unit Compact MONITORING SECURITY SERVICE & SUPPORT 53 rittaldatacentre.co.nz
56 MONITORING CMC III Processing Unit/Compact Benefits: CMC III Processing Unit Compact: Industrial and enclosure monitoring Building monitoring Small monitoring applications in IT CMC III Processing Unit: Larger monitoring applications in IT and industry Material: Plastic Surface finish: Front: Smooth Enclosure: Textured Colour: Front: RAL 9005 (Black) Enclosure: RAL 7035 (Grey) Protection category: IP 30 to EN Supply includes: Basic system Quick-start instructions 4 mounting feet CMC III Processing Unit Compact CMC III Processing Unit W x H x D mm 138 x 40 (1 U) x (front assembly) 138 x 40 (1 U) x (front assembly) Temperature range 0 C to +55 C 0 C to +55 C Operating humidity range 5% to 95% relative humidity, non-condensing 5% to 95% relative humidity, non-condensing Sensors/CAN-Bus connection units max. 4 max. 32 Max. overall cable length for CAN-Bus 1 x 50 m 2 x 50 m Model No. DK Interfaces Inputs and outputs Operation/ signals Protocols Redundant power supply Functions Integral sensors Network interface (RJ 45) Ethernet to IEEE via 10/100BaseT with PoE Ethernet to IEEE via 10/100BaseT with PoE Front USB interface Rear USB interface Front SD-HC slot Rear serial RS232 (RJ 12) Mini USB for system setting 1 x for connecting Display Unit DK or GSM Unit DK or ISDN Unit DK Mini USB for system setting for USB stick for data recording and SW updates up to 32 G 1 x up to 32G for data recording 1 x for connecting Display Unit DK or GSM Unit DK or ISDN Unit DK Digital inputs (terminal) 2 2 Relay output (terminal) Change-over contact max. 24 V DC,1 A Change-over contact max. 24 V DC,1 A CAN-Bus (RJ 45) 1 x for max. 4 sensors 2 x for max. 16 sensors each = 32 sensors in total (quantity restriction, see page 47) (quantity restriction, see page 47) Push-button Concealed reset button Piezo signal generator 1 x acknowledgement button 1 x service button 1 1 x acknowledgement button 1 x service button L ED display 1 x multi-colour OK/warning/alarm 1 x multi-colour OK/warning/alarm Rear LED Ethernet 1 x for the network status TCP/IPv4, TCP/IPv6, SNMPv1, SNMPv3, Telnet, SSH, FTP, SFTP, HTTP, HTTPS, NTP, DHCP, DNS server, SMTP, XML, Syslog, LDAP 1 1 x for the network status TCP/IPv4, TCP/IPv6, SNMPv1, SNMPv3, Telnet, SSH, FTP, SFTP, HTTP, HTTPS, NTP, DHCP, DNS server, SMTP, XML, Syslog, LDAP Input 24 V DC (jack) 1 x for connecting CMC III power pack 1 x for connecting CMC III power pack 1 x for direct connection or 1 x for direct connection or Input 24 V DC (terminals) for connecting CMC III power pack for connecting CMC III power pack Power over Ethernet Time function User administration User interface Control room connection Temperature sensor Access sensor 1 x Real-time clock, energy-buffered (24 h) without battery/accumulator, with NTP LDAP Integral WEB server Integral OPC server NTC sensor in the enclosure front Infrared technology in the enclosure front 1 x Real-time clock, energy-buffered (24 h) without battery/accumulator, with NTP LDAP Integral WEB server Integral OPC server NTC sensor in the enclosure front Infrared technology in the enclosure front 54 RACKS POWER COOLING rittaldatacentre.com.au
57 MONITORING CMC III Accessories Power Pack The CMC III power pack may be integrated into the CMC III assembly unit. CMC Power Supply Input voltage V 50/60 Hz, output vaoltage 24 V DC, 2 A 1 Connection cable/extension required D/F/B: 230 V, Model No. DK , USA/CDN: 230/115 V, Model No. DK C13/C14: 230/115 V, Model No. DK Programming Cable The programming cable is required for commissioning of the Processing Unit (PU) or PU Compact. CMC III programming cable USB CAN-Bus Connection Cable This can be used to connect the PU with the CAN-Bus sensors III, Units III, control units III as a bus. Also for cabling together. CMC III CAN-Bus connection cable RJ CMC III CAN-Bus connection cable RJ 45 1 CMC III CAN-Bus connection cable RJ CMC III CAN-Bus connection cable RJ 45 2 CMC III CAN-Bus connection cable RJ CMC III CAN-Bus connection cable RJ CMC III Mounting Unit, 1 U To accommodate PU, PU Compact, control units, CMC III CAN-Bus unit and CMC III power pack. The mounting unit can accommodate up to 3 units and is secured in the mm (19 ) frame. CMC III mounting unit, 1U 1 CMC III Mounting Unit For Enclosure Frame Can accommodate one unit and is mounted on the enclosure frame. CMC III mounting unit for enclosure frame 1 MONITORING SECURITY SERVICE & SUPPORT 55 rittaldatacentre.co.nz
58 MONITORING CMC III Processing Unit/Compact - System Overview Up to 4 CAN-Bus components are supported. 1 Mini USB: The programming cable DK is required for programming. Integral sensors: - Temperature sensor - Infrared access sensor CMC III sensors: for direct connection CMC III CAN-Bus sensor CMC III Processing Unit Compact CMC II sensors Voltage supply 24 V DC and redudant voltage supply 24 V DC Power packs/connection cables, see page 57 CMC III CAN-Bus access Alarm relay output Changeover contact for safety extra-low voltage Ethernet 10/100 BaseT RJ 45 with PoE: Ethernet interface to IEEE Via 10/100 BaseT full-duplex 10/100 Mbit/s Accessory modules RJ 12/RS232: Display Unit DK ISDN Unit DK GSM Unit DK Two integral digital inputs CMC III CAN-Bus Unit Interfaces unit for connecting CMC II accessories Connection for other products: see page 60 1 Depending on the power supply/connection combinations, see page 60 Contains 2 channels of the PU II Units systems: External 24 V DC supply supported. Model No. DK CMC III CAN-Bus Unit 56 RACKS POWER COOLING rittaldatacentre.com.au
59 MONITORING CMC III Processing Unit - System Overview Mini USB: The programming cable DK is required for programming. Integral sensors: - Temperature sensor - Infrared access sensor CMC III sensors: for direct connection CMC III CAN-Bus sensor CMC III Processing Unit Compact CMC II sensors CMC III CAN-Bus access Voltage supply 24 V DC and redudant voltage supply 24 V DC Power packs/connection cables, see page 57 Alarm relay output Changeover contact for safety extra-low voltage Ethernet 10/100 BaseT RJ 45 with PoE: Ethernet interface to IEEE Via 10/100 BaseT full-duplex 10/100 Mbit/s Up to 16 CAN-Bus systems are supported. 1 Accessory modules RJ 12/RS232: Display Unit DK ISDN Unit DK GSM Unit DK USB Master for data logging and update 1 Depending on the power supply/connection combinations, see page 60 Control Units Two integral digital inputs Up to 16 CAN-Bus systems are supported. 1 CMC III CAN-Bus Unit CMC III 1/0 Unit CMC III Power Unit Contains 8 digital inputs and 4 relay outputs Functions Switching and measurement of voltage, power, output and work. With two outputs. Also for the activation of AC fans. Interfaces unit for connecting CMC II accessories Connection for other products, see page 60 Model No. DK CMC III I/O Unit Model No. DK CMC III Power Unit Model No. DK CMC III CAN-Bus Unit MONITORING SECURITY SERVICE & SUPPORT 57 rittaldatacentre.co.nz
60 MONITORING CMC III Sensors/Accessories Model No. DK PU PU Compact Maximum quantity CMC III I/O Unit, 8 digital inputs + 4 relay outputs CMC III Power Unit, 1 input (C14) + 2 outputs (C13) 230 V, 50/60 Hz Temperature sensor Temperature/humidity sensor Infrared access sensor Vandalism sensor Analog airflow sensor Analog differential pressure sensor Universal sensor (digital input or 4-20 ma or SoBus power meter or Wiegand interface) CMC III CAN-Bus Unit for sensor For connecting the following products: 5 x access sensors (packs of 2), connect a max. of 5 in series 1 x smoke detector 1 x motion detector 1 x voltage monitor 48 V DC 1 x leakage sensor x leakage sensor, with sensor length 15 m /3 x fire detector and extinguisher system DET-AC Plus with 3 messages /3 x early fire detector system DET-AC Plus with 3 messages 1/2 x Door Control System with 2 enclosure channels CMC III CAN-Bus Unit Access (with integral infrared access sensor and interface for one reader III) For connecting the following products: 1 x Ergoform-S handle (el. magn.) 1 x Comfort handle TS 8 (el. magn. TS 8 handle with master key function, with and without CCP) 1 x universal lock 1 x universal handle x CMC III coded lock x CMC III transponder reader CMC III CAN-Bus Unit for 2 unit channels For connecting the following products (note: separate supply via power pack possible): 2 x Fan Control System FCS (DK fan 24 V DC for FCS) x fan mounting plate DC (universal fan roof W x D 800 x 800 mm with FCS) x RFID Controller DRC x 4 x Rittal Power Control Unit (PCU) 8-way x 4 x Rittal Power Control Unit (PCU) C13/earthing pin LED 6-way x 4 x Rittal Power Control Unit (PCU) C13 LED 8-way 2 x 4 x Rittal Power Control Unit (PCU) C13/19 LED 6-way x 4 x PSM socket module active PSM C13 8-way x 4 x PSM socket module active PSM C13/earthing pin 6-way x 4 x PSM socket module active PSM C13/19 6-way x 4 x PSM socket module active PSM C13/earthing pin LED 6-way x 4 x PSM socket module active PSM C13 LED 8-way 2 x 4 x PSM socket module active PSM C13/19 LED 6-way 2 x PSM busbar with measurement 16 A 2 x PSM busbar with measurement 32 A 2 x PSM measurement module 16 A 1) Max. 5 hours and 2) max. 1 hour for power supply with PoE or 48 V power pack. 3) Optional attachment see page RACKS POWER COOLING rittaldatacentre.com.au
61 MONITORING Dynamic Rack Control All IT Components In View At All Times Dynamic Rack Control brings genuine intelligence to the IT rack; after all, the control system thinks for itself. With its automatic inventory monitoring functionality, it is able to document the individual location assignments in the rack and thus the exact position of any given component in real-time. If hardware components change, this is auto matically detected and reported. The objective of Dynamic Rack Control is to protect the IT infrastructure against losses of hardware and data. This is possible thanks to virtual allocation of the hardware built into the rack to infrastructure components such as climate control and power supply to the rack via external management systems. For example, if climate control problems arise in a given rack or suite of racks, it is possible to identify the affected server hardware at any time. The ingeniously simple installation and straightforward handling of Dynamic Rack Control are the keys to effi cient cost reductions. Various data records are available on all RFID tags for inventorisation information and device-specifi c data records. To this end, every mm (19 ) component is equipped with a self-adhesive RFID tag. If a device is removed from a rack, the Dynamic Rack Control reports an alarm. When installing the device in a different rack (or U), the information about the original installation location is immediately available. This effectively prevents incorrect population of the rack, for example following maintenance work on a server. MONITORING SECURITY SERVICE & SUPPORT 59 rittaldatacentre.co.nz
62 MONITORING Dynamic Rack Control All IT Components In View At All Times Your Rittal Benefits Automatic detection of the components in a rack Independent server rack assignments Real-time signalling of status changes Precise position determination for each U in the rack Integration into existing monitoring systems Management of the electrical load and power losses of each component in the rack Up-to-date information on cooling capacity and power supply reserves Optional integration into the data centre management software RiZone Interfaces: SNMP, XML Mounting Position Of Components In The IT Rack Correct hardware positions are confi rmed by LEDs on each U. Installation positions may also be visually marked for the service personnel. By combining with infrastructure information, each rack may be optimally confi gured with mm (19 ) hardware. The overview of the IT infra structure is upto-date at all times. RFID Reader The integral RFID reader in the rack continuously supplies all important information. The hardware information (e.g. hardware manufacturer, type of component, date of installation, energy consumption, service appointments), which is stored on the RFID tags, is also permanently available. This constantly updated information makes the day-to-day operation of your data centre much easier. Automated Documentation IT infrastructures today are exposed to a powerful momentum but must always be up-to-date. This can only be achieved with automated solutions. To this end, Rittal offers innovated, automated documentation. 60 RACKS POWER COOLING rittaldatacentre.com.au
63 MONITORING SECURITY SERVICE & SUPPORT 61 rittaldatacentre.co.nz
64 MONITORING RiZone Perfect Data Centre Management RiZone is the management platform for all components in the data centre infrastructure. The system enables the monitoring of redundant data centres (up to Tier IV). RiZone is quickly confi gured via the automatic recognition of all active Rittal system components, and thanks to a modular licence model is tailored precisely to the requirements of your IT applications. The administration of the physical infrastructure (from miniature data centres to large, high-mbtf data centres) is effi cient, highly fl exible and ensures high availability. RiZone can communicate with a server management system (e.g. System Center Operations Manager from Microsoft) and exert direct infl uence over the availability of individual applications. Only the consistent merging of information from the data centre will allow the availability status of the IT infrastructure to be accurately assessed. With this information, weaknesses can be automatically detected and eliminated. Rittal RiZone allows energy consumption in the data centre to be adjusted and optimised. Efficiency Example To correspond to the power consumption of your data centre, the cooling output must be designed for maximum performance in unfavourable ambient temperatures. As this diagram of weekly operation shows, unless properly managed, a typical cooling system is oversized most of the time. Here, RiZone saves energy by intelligently adapting the cooling output to the power consumption, airfl ow and ambient temperature. Your Rittal Benefits Optimised availability Simplifi cation by reducing complexity Enhanced effi ciency of the data centre Individual representation of the entire IT infrastructure Diagrammatic representation of history values Calculation of variables such as PUE Automatic generation of reports Automatic detection of Rittal system components Support of the SNMP protocol Workfl ow editor for automated processes High-MBTF application Link to server management system Selectable software or hardware appliance KW MON TUE WED THU FRI SAT SUN Sub-optimum cooling output Optimum cooling output Heat load (IT load) The Main Aim Is Availability Linking the physical data centre infrastructure to server and application management achieves consistent monitoring of the IT services. The early detection of malfunctions allows prompt action to be taken, and ensures compliance with SLAs. Live Representation Of The Rack Status Rittal RiZone supports live, clear representation of the current operating status of a rack. This facilitates reliable monitoring and administration, as well as a fast response in the event of malfunctions and deviations. All key parameters relating to the server rack are incorporated into monitoring; RiZone represents the operating status of the entire rack with the colours red, amber and green. 62 RACKS POWER COOLING rittaldatacentre.com.au
65 MONITORING RiZone See Your IT In Context From Now On Mindful of availability, rationalisation and future orientation, the physical infrastructure of the IT landscape must be viewed in context. RiZone creates this context! Key for security: Take preventive action! RiZone identifi es hot spots on servers or pending phase overloads early on, and responds immediately. This creates peace of mind. Key for resource planning: Identifying trends! Extensions to IT may be implemented transparently using RiZone. Permanent monitoring supplies clear data on any trend developments, enabling the user to respond promptly to any bottlenecks, and reliably plan the expansion or improvement of the IT infrastructure. Key for energy efficiency: Optimise functions! RiZone represents the energy consumption of individual racks and complete data centres, and supplies the PUE (Power Usage Effectiveness) of all components for energetic optimisation of the data centre. RiZone Simple, Comprehensive And Profitable For Users All active Rittal data centre components are automatically detected and administered in the user interface. Any components that support the SNMP protocol may be incorporated and are able to use all RiZone functions. A workfl ow editor represents all mathematical operations and confi gures components comprehensively for optimum linking of all parameters, and therefore offers brand new opportunities for optimising the entire infrastructure. Customer-focused licence model: All potential applications from the server room to the data centre may be represented. Be it a one-rack data centre or a large server farm, protecting the availability of the IT infrastructure is unrelated to the size of the company; RiZone always offers full functionality for controlling and monitoring all IT components. RiZone can be adapted to the size of the company with a fl exible licence model. MONITORING SECURITY SERVICE & SUPPORT 63 rittaldatacentre.co.nz
66 64 RACKS POWER COOLING rittaldatacentre.com.au
67 SECURITY SOLUTIONS IT Security Solutions Targeted Physical Protection For Your IT IT Security Rooms And Safes With Rittal IT security rooms and security safes, we offer a broad spectrum of products for the physical protection of your IT, ranging from basic protection through to high-mtbf protection. The system-tested solutions protect against fi re, water, dust, fumes and external access. With the modular room-within-a-room solution, you invest and expand according to your individual requirements, while the option to dismantle and reassemble the system ensures fl exibility and protects your investment. The Rittal complete security solution also includes climate control, power distribution, an uninterruptible power supply, monitoring, fi re detection and extinguishing. LSR 18.6 E high security door system Secure Airfl ow Ducts for Direct Free Cooling The Benefits To You: Protection ranging from basic protection to high-mtbf Simple, fl exible integration into existing building structures Expandability and lasting cost-effectiveness Optimum space utilisation, thanks to the fl exible modular system Flexibility, by enclosing existing IT and infrastructure solutions System-tested protection from potential physical threats Room-within-a-room concept with the associated depreciation benefi ts Compatibility with Rittal data centre solutions High level of pre-manufacturing fast assembly times May be constructed and extended with the IT systems operational Plus: The Data Centre Container as a temporary main or backup data centre for outdoor areas LSR18.6 E with 19 racks Fire Alarm And Extinguisher Systems As well as protecting against potential threats from the environment, the various fi re alarm and extinguisher systems focus on identifying and extinguishing a fi re inside the data centre. Early fi re detection combined with an active extinguisher system prevents the destruction of your IT systems and associated data losses, and therefore safeguards your corporate processes. LER Extend with Power Distribution / UPS MONITORING SECURITY SERVICE & SUPPORT 65 rittaldatacentre.co.nz
68 SECURITY SOLUTIONS IT Security Rooms Reliable Protection, System-Tested The Rittal security rooms LER Basic, LER Extend and LSR 18.6 E allow you to choose between basic protection, extended protection or high-mbtf protection for your data centre. Thanks to the modular layout of the rooms and the wide range of options available, we will provide you with precisely the protection services your IT needs. The table below provides an insight into the Rittal security room concept. Criterion Standards Conventional design 2 LSR 18.6 E LER Extend LER Basic System testing Testing of the following standards as complete system or structure 1 X Fire protection Testing at temperatures of up to more than 1,000 C ECB S certifi cations to EN , 50 K temperature increase and 85% rel. humidity up to 24 hours (reheating period), 60 minutes fl ame impingement time X X X 50 K temperature rise and 85% rel. humidity over 30 minutes, without reheat period X X F120 as system test to EN 1363 (DIN 4102), for the cellular structure and its built-in modules X X X F90 as system test to EN 1363 (DIN 4102), for the cellular structure and its built-in modules X F180 only as component testing to EN 1363 (DIN 4102), wall system only X X X F120 only as component testing to EN 1363 (DIN 4102), wall system only F90 only as component testing to EN 1363 (DIN 4102), wall system only Explosion Detonation test as system testing of 200 kg TNT from 40 m X X X Water Standing water, 72 hours, 40 cm, maximum 20 drops X X X Extinguisher water, IP x6 as system testing to EN 60529, for the cellular structure and its built-in modules X Relative humidity, 85%, over 24 hours (reheat period), 60 minutes fl ame impingement time, to EN X X X Relative humidity, 85%, over 30 minutes X X Dust-tightness IP 5x as system test to EN 60529, for the cellular structure and its built-in modules X 3 Corrosive fire gases Acrid gas-tightness, based on EN (DIN 18095) X Unauthorised access Falling debris EMC protection WK 3 as system test to EN 1627/1630, for the cellular structure and its built-in modules, such as doors X WK 2 as system test to EN 1627/1630, for the cellular structure and its built-in modules, such as doors X WK 4 only as component testing to EN 1627/DIN 1630, door system only X X X Shock test as system test, 3 shocks of 200 kg from 1.5 m after 45 minutes fl ame impingement time X X X Shock test as system test, 1 shock of 200 kg from 1.5 m after 30 minutes fl ame impingement time X Protection against high-frequency irradiation and radiation, verifi ed by tests on comparable components by TU Aachen X EMC optional package Extended high-frequency shielding in accordance with BSI TL X X X 1) System-tested products are tested as a complete construction. This comprises the cellular structure and installation modules such as doors, cable shields or ventilation units. By contrast, component testing only refers to individual parts. 2) The conventional design refers to room structures of plasterboard, concrete and other standard construction materials which do not offer suffi cient protection for data centre applications. Conventional designs are generally tested for use as fi re walls. 3) Tested to EN 60529, category 1 (underpressure). 66 RACKS POWER COOLING rittaldatacentre.com.au
69 SECURITY SOLUTIONS IT Security Rooms From Basic Protection To High-MTBF Scalable Room Solutions From Rittal Rittal offers cost-effectively expandable designs and structures, with ecologically and economically optimised data centres offering a host of other benefi ts: Turnkey handover of the data centre Scalability Selection of the most cost-effective solution Investment protection thanks to modularity and expandability Option of installation with the system operational Fast availability High-MTBF Protection As a high-mtbf solution, the Rittal security room LSR 18.6 E offers maximum physical protection for data centres and IT system locations. The system was certifi ed by ESSA (European Security Systems Association) to ECB S regulations. This certifi cation confi rms that the LSR 18.6 E meets the requirements of EN without restriction. Moreover, construction of the security room is subject to constant, independent quality monitoring. LSR 18.6 E High-MTBF protection for data centres High level of pre-production of elements, which reduces dust and noise during assembly Fire protection to quality class R60D to EN (fi re resistance testing, shock testing, fl oor testing) Protection against external access Resistance category WK 3, optionally WK 4 based on EN 1627 Protection against standing water, 72 h, 40 cm, maximum 20 drops Explosion testing to SEAP standard Extended protection against falling debris Dust and water tight to IP 56, category 1 (underpressure) to EN Optionally extendible EMC protection to BSI TL Benefits Of ECB S Certification Optimum quality protection thanks to independent quality monitoring Improvement in the rating situation for loan applications and residual risk insurance Transparency for banks and insurance companies Compliance with European standards on IT protection LSR18.6 E for high security data centres Standard protection from: Fire Extinguishing water Corrosive gases Vandalism Unauthorised access Electromgn. interference Dust Explosion Falling debris Theft/ Mechanical burglary access Shot-proofing MONITORING SECURITY SERVICE & SUPPORT 67 rittaldatacentre.co.nz
70 SECURITY SOLUTIONS IT Security Rooms From Basic Protection To High-MTBF Basic Protection And Extended Basic Protection The security rooms LER Basic and LER Extend offer highquality, system-tested solutions for the basic protection range. As basic and extended solutions, LER Basic and LER Extend are optimum technical rooms for the protection of infrastructure components such as extinguisher systems, uninterrupted power supply etc. LER Extend Extended basic protection for data centres based on the LER Basic Fire resistance testing over 90 minutes F90, according to the limits of EN 1363 plus compliance with the limits of ECB S requirements pursuant to EN over 30 minutes LER Basic Basic protection for data centres or infrastructure solutions Fire resistance over 90 minutes F90 according to the limits of EN 1363 Dust and water tight to IP 56 to EN Protection against external access Resistance category WK 2, optionally WK 3 based on EN 1627 EMC protection Acrid gas-tightness based on EN Shock test with 3,000 Nm energy Standard protection from: Fire Extinguishing water Corrosive gases Vandalism Unauthorised access Electromgn. interference Dust Falling debris Theft/ burglary Fully System-tested All Rittal security systems are system-tested. System-tested products are tested as a complete structure, taking into account the interactions between all components. During testing, allowance is made for built-in modules such as doors, cable shielding systems and ventilation units. Benefi t from multifunctional risk coverage (fi re, water, burglary etc.) and compliance with the latest EN and DIN standards. LER Extend for infrastructure areas 68 RACKS POWER COOLING rittaldatacentre.com.au
71 SECURITY SOLUTIONS IT Security Safes A Complete Mini Data Centre, Flexible, Modular, Requirement Based Solutions The Rittal product range offers the ideal solution for every level of business security. Like security rooms, security safes also provide optimum protection against potential physical threats to your IT applications. Particularly for small and mediumsized enterprises, the compact safes represent an optimum protection concept as a physical cover for individual server racks. Features such as modu larity and extendibility guarantee investment protection and fl exibility. Scalable protection levels allow you to select the solution best suited to your needs. Rittal IT Security Safe As well as a physical cover in the form of an IT security safe, the confi guration components listed below complement the Rittal safe and transform it into a fully fi tted compact data centre. Energy-effi cient climate control in different variants Modular power distribution Fire alarm and extinguisher systems Monitoring system Server rack as mm (19 ) supporting structure MONITORING SECURITY SERVICE & SUPPORT 69 rittaldatacentre.co.nz
72 SECURITY SOLUTIONS Modular Safe Extend Maximum Security In A Minimal Space IT security = A combination of technical, logical and physical security. As the optimum solution for small and medium-sized enterprises, the Rittal Modular Safe Extend represents one of these pillars by protecting against potential physical threats. The system offers a complete range of security for one or more server racks. As well as facilitating installation in poorly accessible sites, the modular design also makes it possible to enclose existing IT structures. Extendibility, dismantling and re-assembly facilitate a targeted, future-safe investment. The security safe is prepared for the installation of a requirementbased climate control system. The optional confi guration components complete the modular safe and transform it into a complete compact data centre. As well as the side, top and base elements, the modular safe is also equipped with an operator door and a service door, to ensure optimum accessibility. There are cable entry systems in both side elements. The safe is available in different variants to match your requirements. The Protection Categories: Fire protection F90 (DIN 4102), compliance with limit values 70 C and relative humidity < 85% for 30 minutes. Burglary protection WK 2 (EN 1627) Optional burglary protection WK 3 and WK 4 (EN 1627) Protection against dust and water jets IP 56 (EN 60529) Protection from acrid gases (DIN 18095) Your Rittal Benefits With The Modular Safe Extend Extended basic protection for compact data centres System-tested protection Compatibility with other infrastructure elements Systems may be dismantled and reassembled, for maximum investment security Targeted investment, thanks to extendibility High level of pre-production of elements, which reduces dust and noise during assembly Flexibly by enclosing existing IT structures High level of operational and service-friendliness thanks to the two-door system Numerous options available Available in 42 U and 47 U Available for 1,000 mm and 1,200 mm deep racks Standard protection from: Fire Extinguishing water Corrosive gases Vandalism Unauthorised access Dust Theft/burglary 70 RACKS POWER COOLING rittaldatacentre.com.au
73 SECURITY SOLUTIONS Modular Safe Light & Basic Safe Compact Flexible Protection For Compact And Miniature Data Centres Modular Safe Light The Rittal Modular Safe Light is a basic protection solution for one or more server enclosures or compact data centres. Thanks to its reduced weight, the Modular Safe Light is also particularly suitable for locations with limited fl oor load-bearing capacity. As an optional single-door system the safe also offers a solution for confi ned spaces. Basic Safe Compact The Rittal Basic Safe Compact offers solid basic protection for miniature data centres. The climate control is integrated into the system. The protection categories: Fire protection F90 (DIN 4102) with compliance with the limits 70 C and rel. humidity < 85% over 10 minutes, protection against dust and water jets IP55 (EN 60529) and burglary protection WK 2 (EN 1627). The system is assembled in the factory and delivered in an operational condition. Your Rittal Benefits With The Modular Safe Light (Product properties deviate from the Modular Safe Extend) System testing for single safe with two-door system Weight reduction Available in 47 U and 33 U for 1,000 mm deep racks Fire protection F30 Anti-theft protection WK 2 Your Rittal Benefits With The Basic Safe Compact Basic protection for miniature data centres Delivery of the complete system with built-in climate control Compatibility with other infrastructure elements High level of operational and service-friendliness thanks to the two-door system MONITORING SECURITY SERVICE & SUPPORT 71 rittaldatacentre.co.nz
74 SECURITY SOLUTIONS Fire Alarm And Extinguisher System DET-AC XL Fires Are Rapidly Detected And Reliably Extinguished The Rittal fi re alarm and extinguisher system DET-AC XL is a standardised solution for extinguishing individual bayed suites of up to 24 enclosures or entire rooms. All components of the system are built into a 300 or 600 mm wide TS 8 enclosure, facilitating optimum baying to a suite of server enclosures. The integral early-warning fi re detection system with active smoke extraction detects fi re even at the pyrolysis phase and emits a pre-alarm. Extinguishing does not occur until the main alarm is triggered, to avoid accidental activation. NOVEC 1230 is used as the extinguisher gas. Rittal DET-ACXL units are installed according to AS (Gas Suppression) and AS16070 Part 1, 2004 (Automatic Fire Dectection System). As Room Application The DET-AC XL may be used as a room application for rooms up to a volume of 84 m³. In addition to the early-warning fi re detector with active smoke extraction system, several smoke alarms are also positioned in the room. Extinguishing is activated via cross-zoning. For The Detection And Extinguishing Of Rack Suites Up to 24 server enclosures can be detected and extinguished with the DET-AC XL. The system may be installed at the end of a suite of racks, but also between two server enclosures. Piping for the smoke extraction system and extinguisher gas is laid in every enclosure. Your Rittal Benefits Automatic extinguishing with the extinguisher gas NOVEC 1230, which is eco-friendly and harmless to humans and IT Fire detection at a very early stage (pyrolysis phase) Compact design, modular principle 72 RACKS POWER COOLING rittaldatacentre.com.au
75 SECURITY SOLUTIONS Fire Alarm And Extinguisher System DET-AC Plus Smoke Extraction And Active Extinguishing Rittal DET-AC Plus is a compact fi re alarm and active extinguisher system with smoke extraction system in one unit. The mm (19 ) rack mount only requires 1 U of space. With the extinguisher NOVEC 1230 integrated in a shallow tank, a volume of up to 3 m³ may be extinguished. The integral smoke extractor system continuously extracts the air from the enclosure via a pipe, and passes it over two smoke detectors. The fi rst smoke detector is extremely sensitive and triggers a pre-alarm. The second smoke detector triggers the main alarm and hence extinguishing. In conjunction with the DET-AC Plus slave system, up to fi ve bayed enclosures may be extinguished. For detection purposes, the pipework from the DET-AC Plus master system is laid in all enclosures. A DET-AC Plus slave system is positioned in each additional bayed enclosure and contains the extinguisher medium for that enclosure. Detection and activation of extinguishing for all enclosures is handled by the DET-AC Plus master. Your Rittal Benefits Automatic extinguishing with the extinguisher gas NOVEC 1230, which is eco-friendly and harmless to humans and IT Minimal space requirements with just one U per enclosure Active smoke extraction system and therefore early fi re detection EFD Plus For pure fi re detection, the EFD (Early Fire Detection) Plus system is available. EFD Plus is a fast, effective and inexpensive option for safeguarding corporate processes and preventing physical damage. The active smoke extraction system facilitates early detection. Two smoke sensors of differing sensitivity emit a pre-alarm and a main alarm. = DET-AC Plus = DET-AC Plus Slave = EFD Plus MONITORING SECURITY SERVICE & SUPPORT 73 rittaldatacentre.co.nz
76 DATA CENTRE CONTAINER Data Centre Container Your Complete Data Centre In A Container The Rittal Data Centre Container has been specifi cally designed for the mobile or temporary use of IT systems. Ideal for use during conversion and expansion work and when relocating your IT. The system can also be used as a permanent IT or server room or as a main or backup data centre. The absolute highlight is the innovative, direct free cooling. It saves up to 40% of cooling costs, and also guarantees seamless integration of a UPS, fi re alarm/extinguisher system, power supply and distribution, raised fl oor, cold aisle containment, access control and monitoring functions. Even the basic version of the container data centre is a fully functional system. Suitable option packages can be added to the basic model. Be it linked containers, more than seven racks or higher cooling outputs, in addition to the standard model range of 12 preconfi gured data centre types, we are also happy to devise special solutions. 74 RACKS POWER COOLING rittaldatacentre.com.au
77 DATA CENTRE CONTAINER Data Centre Container Your Complete Data Centre In A Container Your Rittal Benefits Simple planning Fixed price for data centre Mobile all-in-one concept No external assemblies, short-term location changes are possible High energy effi ciency thanks to innovative, direct free cooling, effi cient UPS with high effi ciency and PUE (Power Usage Effectiveness) of less than 1.2 With plenty of space for up to 329 U (7 racks) and max. 6 kw/rack Extra-wide (3 m) and very robust outdoor container Plug & play solution: Position connect and it s ready to go! Available in next to no time Confi guration to order Protection properties: Resistance to wind, rain, heat and cold Long autonomy in case of power failure, at least 15 minutes Monitoring and management of data centres and infrastructure via CMC-TC and RiZone Technical Data For The Basic Model Basic container Particularly generous dimensions: External (L x W x H) 6055 x 3000 x 3250 mm, internal (L x W x H) 5722 x 2664 x 2896 mm, useful area: 15.2 m2 Length variations 3-12 m possible Climate control direct free cooling Available as 7 and 10 kw unit. Up to 6 units can be integrated. Power distribution Infeed: CEE wall unit connector 125 A, 3-phase/N/PE, 400 V/50 Hz Enclosure dimensions (W x H x D): 600 x 2000 x 400 mm Raised floor Substructure type: Control room, heavy duty Number of slotted plates dependent on number of racks Total raised height: 300 mm Bulkhead system Type: Hard bulkhead DN200 Dimensions of packing space: 120 x 120 mm Protection standards Fire protection of internal panels to EN 1363/DIN 4102: F30, optionally F90, type-tested Burglary protection, security door to EN-1627/EN-1630: Anti-theft protection WK 2, optionally WK 3 The Packages: Access control Cable shielding system Climate control technology Power technology/ UPS Fire detection/ fi re extinguishing Base system Service/ maintenance Lighting system Monitoring Project management Optical package Data and network technology mm (19 ) rack system Power distribution Solar protection Cold aisle containment MONITORING SECURITY SERVICE & SUPPORT 75 rittaldatacentre.co.nz
78 DATA CENTRE CONTAINER Data Centre Construction And IT Infrastructures Perfectly Coordinated Rittal drafts, plans and implements high-mtbf data centres and IT environments that are super-effi cient in every respect. Based on your requirements, our engineers and expert planners will devise optimised, perfectly functioning IT centres for every size of company. This means that you only have one project partner: Rittal. As general contractors, site managers and your point of contact, we will coordinate the complex work operations on your behalf. With our supremely well-organised process and project management system, we will reduce interfaces, coordinate the various works, clarify your detailed questions on site, and strictly adhere to the agreed timetables. The fi nished outcome will be a perfect, turnkey data centre complete with all components: Server racks, network enclosures, power distribution, climate control, effi ciency management and the necessary monitoring and security components. Upon request we will also take care of your security and energy effi ciency certifi cations (e.g. TÜV-ITIER) and appropriate emergency planning concepts. Only infrastructures with coordinated components will achieve full performance in the long term. Rittal incorporates this into the planning stage, and you will reap the benefi ts with regard to implementation and service. You will receive modular, scalable solutions from a single source cooling, power, security room, monitoring, management and service. Rittal The System. Faster better worldwide. The components we have selected for you are tried and tested, thereby reducing any required adjustments between equipment and solutions from possible external suppliers to a bare minimum. As a complete supplier, we will also optimise the interactions between hardware and individual data centre software on your behalf in the following areas: Settings, monitoring, process optimisation, effi ciency control, emergency messages, maintenance etc. With our global, solid experience and broad product portfolio, we will create a secure, highly effi cient basis for your entire IT infrastructure. You will benefi t immediately from maximum performance capability, combined with permanent reliability, stability and availability. Data Centre Construction Engineering & design to implement complete data centres Site management and execution as general contractors Project and process management of the entire workfl ow Handling of all licensing procedures (construction application, statics and other approvals) Preparation of various certifi cations, including the relevant international certifi cates (safety, energy effi ciency, availability) IT Infrastructures Standardised server racks and network enclosures Scalable IT cooling concepts Modular power distribution and backup High-MTBF IT security rooms, including certifi cates Complete system accessories for IT environments and data centres Software-based IT and infrastructure management system Rittal endorses the European Code of Conduct and strives consistently to achieve its goals. 76 RACKS POWER COOLING rittaldatacentre.com.au
79 MONITORING SECURITY SERVICE & SUPPORT 77 rittaldatacentre.co.nz
80 SERVICE & SUPPORT Engineering & Design Concept-Based IT Power Rittal The System. Faster better worldwide. means innovative strength plus IT expertise plus decades of experience, all from a single source. Thanks to our intelligently compiled portfolio of solutions, we will continuously supply you with ideas, concepts, innovations and the exact IT solution you need for your company, right from day one. With Rittal, you can commit to high-end solutions: Engineering & consulting, data centre construction, IT infrastructures, and the international Rittal service. Utilise the knowledge, experience and products of a successful global player, for yourself and your IT. Rittal develops and optimises individual ITC solutions on your behalf, from small IT units to complex data centres. Our specialists will precisely analyse the current status and future requirements, the structural and physical conditions, and the existing IT structures, and on this basis will tap into proven optimisation potential. This will facilitate the planning and implementation of IT systems with maximum effi ciency in terms of performance, costs, processes, energy input, compatibility, availability and security. Rittal s technical and detailed planning teams will conduct all the necessary analyses and calculations, prepare all the drawings and documents, and select the optimum solutions and com ponents for your IT environment. Engineering & Design Site evaluation and risk assessment Design and planning of complete data centres Optimisation of existing data centres with regard to energy, costs, processes, security, disaster recovery management and outsourcing External assessment of data centre and infrastructure concepts Effi ciency analyses of energy, climate, security and IT processes 78 RACKS POWER COOLING rittaldatacentre.com.au
81 SERVICE & SUPPORT Rittal Global Service Global Security And Availability Everything works perfectly. You needn t worry about a thing. Rittal Global Service ensures your satisfaction, peace of mind and availability, 24 hours a day, 7 days a week, 365 days a year. Wherever you use our products, Rittal Global Service is there for you! We are on a worldwide mission to ensure that every aspect of Rittal The System. is exactly as it should be: perfect. Faster Short paths, fast communications: With regional service support points A perfect interplay between sales, project management and service Better Individual service solutions from a single source A global high standard of qualifi cations among Rittal service technicians A uniform global service ticket system Service From A Single Partner 24/7 service reachability, 365 days a year Highly qualifi ed service specialists Service technicians on site within 8 hours Automated incident and emergency management Individual availability of spare parts Global service ticket system You decide for yourself the format and scale in which you use the Rittal Global Service. You can choose from four standardised service packages: Basic, Comfort, Advanced and Full. Above and beyond this, you can agree further special conditions via our individual service packages. Worldwide 5 service support points worldwide More than 250 service partners and over 1,000 service technicians Represented in over 60 subsidiaries with service An Overview Of The Features Of The Various Rittal Service Packages: Service Contract Matrix Reachability Response time Spare parts availability Maintenance Warranty extension BASIC Business hours Next working day Standard 1 x per annum Optional COMFORT Business hours Next day Standard 2 x per annum Optional ADVANCED FULL CUSTOMISED 24 hours 365 days a year 24 hours 365 days a year Next day 24 hours 2 x per annum Yes 8 hours Individual concept Individual by arrangement Individual (at least 2 x/year) Yes MONITORING SECURITY SERVICE & SUPPORT 79 rittaldatacentre.co.nz
82 Notes 80 RACKS POWER COOLING rittaldatacentre.com.au
83 Notes MONITORING SECURITY SERVICE & SUPPORT 81 rittaldatacentre.co.nz
84 Notes 82 RACKS POWER COOLING rittaldatacentre.com.au
85 Notes MONITORING SECURITY SERVICE & SUPPORT 83 rittaldatacentre.co.nz
86 Notes 84 RACKS POWER COOLING rittaldatacentre.com.au
87 References UNIVERSITY OF SOUTHERN QUEENSLAND MODULAR AND SCALABLE Supporting three campuses, 2,000 staff and 25,000 students, requires secure, reliable and scalable IT infrastructure. With signifi cant growth in recent years USQ needed a new central data centre to centrally process information from three campuses. To support a demanding 24/7 IT load the university commissioned Rittal to provide an effi ciency room. This facility protects critical IT assets and information against fi re, vandalism, water, debris and theft. The Rittal Effi ciency Room was specifi cally chosen for its modularity and scalability; as USQ s data processing requirements grow, so can their security room without the need for welding or grinding around sensitive IT systems. Despite a budgeted build of fourteen days, Rittal s certifi ed installation team was able to build the Rittal Effi ciency Room in just seven days. USQ experienced no down time or interruptions to their existing data centre operations as the old legacy infrastructure was decommissioned, and the Rittal solution was installed. MICROSOFT ENERGY EFFICIENT AND FLEXIBLE The world s leading software developer Microsoft has set up a special data centre at the corporate headquarters in Redmond to enable its customers to test new software ahead of productive deployment. In the Enterprise Engineering Centre, over 700 servers are used to simulate the IT environments of enterprise software customers, removing the risk of surprises when it comes to actual implementation of next generation products. Following expansion of the test laboratory in 2009, Microsoft can now depict the impacts of migration on energy consumption at an even fi ner resolution. To this end, Microsoft has chosen IT infrastructure from system supplier Rittal: The new data centre has been equipped with the energy-effi cient and scalable cooling system LCP Plus and high-load server enclosures from the TS 8 range. Rittal is an offi cial Microsoft Gold Certifi ed Partner. MONITORING SECURITY SERVICE & SUPPORT rittaldatacentre.co.nz
88 HEAD OFFICE AUSTRALIA Parraweena Road, Miranda NSW 2228 Australia T E [email protected] W rittaldatacentre.com.au rittal.com.au HEAD OFFICE NEW ZEALAND 21 Bell Road South, Lower Hutt Wellington NZ T E [email protected] W rittaldatacentre.co.nz rittal.co.nz SYDNEY CANBERRA MELBOURNE BRISBANE ADELAIDE PERTH AUCKLAND WELLINGTON CHRISTCHURCH RACKS POWER COOLING MONITORING SECURITY SERVICE & SUPPORT
Rittal Data Centre Solutions
issue THREE Rittal Data Centre Solutions RACKS POWER COOLING The simple route to the perfect data centre Data centres are complex systems. Software, hardware and IT infrastructure must work together seamlessly
IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre
IT infrastructure Efficiency-boosting solutions nextlevel for data centre 2 Rittal IT infrastructure The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind,
RiMatrix S Make easy.
RiMatrix S Make easy. 2 RiMatrix S Rittal The System. The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure, power
Data Centre Solutions
Issue 6 Data Centre Solutions RACKS POWER COOLING MONITORING SECURITY SERVICE & SUPPORT The simple route to the perfect data centre Data centres are complex systems. Software, hardware and IT infrastructure
Data Centre Solutions
Issue 5 Data Centre Solutions RACKS POWER COOLING MONITORING SECURITY SERVICE & SUPPORT The simple route to the perfect data centre Data centres are complex systems. Software, hardware and IT infrastructure
Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE
Local Area Networks (LAN) Servers Data centers Internet centers (ISP/ASP/POP) Industrial PLCs EPOS (Electronic Point of Sale) Systems Emergency devices (lights/alarms) Electro-medical devices Telecommunication
Cabinets 101: Configuring A Network Or Server Cabinet
Cabinets 101: Configuring A Network Or Server Cabinet North, South and Central America White Paper May 2012 www.commscope.com Contents Background Information 3 What is a network or server cabinet? 3 What
Rittal The System. Faster. Better. Worldwide CLIMATE
IT infrastructures Rittal The System. Faster better worldwide: Everything we do centres around the benefits to you. For you, we have developed a perfectly coordinated system platform that unites innovative
Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS
Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS STANDARD & ECONOMICAL BasicRack A complete low-cost, high-quality basic equipment management system. Design Six web channel holes per side allow
Powerware Enclosure Solutions Product Focus
Powerware Enclosure Solutions Product Focus Powerware Enclosures IT availability and reliability are critical corporate issues in today s demanding, mission-critical environments. For this reason, it is
2 Rittal Micro Data Centre
Micro Data Centre 2 Rittal Micro Data Centre The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure, power distribution,
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels
30-120 3 Phase Modular Finally the benefits of Modular ups are for all
MUST 30-120 3 Phase Modular UPS Finally the benefits of Modular ups are for all MUST 30-120 MUST means Modular UPS System Three-phase MUST 30-120 is an uninterruptible power supply with double conversion
How To Use Rittal'S Rizone
RiZone Data Centre Infrastructure Management Enclosures Power Distribution Climate Control IT INFRASTRUcTURe SOFTWARE & SERVICEs RiZone Data Centre Infrastructure Management What can the RiZone Data Centre
Cabinet V800 V800 CABINETS
V800 Cabinet Siemon s V800 cabinets provide a robust, cost-effective enclosure solution that provides valuable Zero-U space on each side of the equipment rails for cable management, PDU mounting or connectivity
Rittal the time has come...
Rittal the time has come...... for the Data Centre of the future Sustainable energy efficiency! Energy Outstanding climate protection and energy efficiency with Green IT. Modular, scalable IT infrastructures
The UPS for the highest security in industry and data centres
The UPS for the highest security in industry and data centres P R E M I U M 6,000-20,000VA T E C H N O L O G Y www.online-usv.de Perfect: The ultimate protection against blackout and data loss The new
Rack Systems Solutions
Rack Systems Solutions Designed to simplify cable management and improve power distribution Engineered by APC by Schneider Electric for Dell, NetShelter S is the next-generation rack enclosure solution
CRAC Precision climate control units for data centres
CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have
How To Build A T7 Rack For Information Technology
THE NEXT GENERATION RACK FOR INFORMATION TECHNOLOGY THE RACK CABINET FOR INFORMATION TECHNOLOGY T7, THE HI-TECH HEART OF THE BLADESHELTER SYSTEM The real answer to the requirements of: Safety Versatility
InstaPATCH ZERO Solution Guide
SYSTIMAX Solutions InstaPATCH ZERO Solution Guide Rapid Server Deployment and Change Management North, South and Central Americas 1 As data centers face ever-increasing IT demands, growth demands and evolving
Power distribution in data centres
Power distribution in data centres by Manuel Lotz / Matthias Ribbe White Paper 09 Copyright 2008 All rights reserved. Rittal GmbH & Co. KG Auf dem Stützelberg D-35745 Herborn Phone +49 (0)2772 505-0 Fax
Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers
Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers An intelligent physical infrastructure is required
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
Technical data UNIBLOCK UBSF 180 625
Data TECHNICL DT Technical data UNIBLOCK UBSF 80 6 Output data Type UBSF 80 UBSF 0 UBSF 00 UBSF 6 Output power 80 kv 0 kv 00 kv 6 kv Output voltage 80/77 V 0/ V 0/ V 0/ V Output current 7 8 66 80 Power
Rittal Data Center Enclosures Modular and wallmount enclosures, racks and accessories
Rittal Data Center Enclosures Modular and wallmount enclosures, racks and accessories Rittal TS8 Modular and Wallmount Enclosures and Racks Your Data Center Partner Rittal TS8 Modular Enclosures Rittal
PowerGem Pro Uninterruptible Power Supply
Uninterruptible Power Supply User-friendly Intelligent Ultra reliable Range The Most Intelligent On-Line Double Conversion Power Protection System The range achieves higher reliability and greater immunity
LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification
08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and
Material test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
SERVER ROOM CABINET INSTALLATION CONCEPTS
SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS ZPAS 169 EXAMPLES OF SERVER ROOMS PROJECTS WITH ZPAS CABINETS Data Box in the
MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4
CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,
DIGITUS Network & Server Cabinets. UNIQUE Series
DIGITUS Network & Server Cabinets UNIQUE Series Benefits - Server Rack 4-Point locking system front door 3-point locking system rear door Swing handle lock with profile zylinder in front and rear door
Table of Contents. RimatriX5 IT Solutions from Rittal. Product Overview Section 1... Pages 3-11. Enclosures Section 2...
Rittal IT Solutions Table of Contents RimatriX5 IT Solutions from Rittal Product Overview Section 1... Pages 3-11 Enclosures Section 2... Pages 12-51 Cooling Section 3... Pages 52-73 Monitoring and Security
SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications
SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications Model #: SU3000RTXL3U 3000VA online 3U rack / tower UPS Enhanced serial communications
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
4.0 UPS dedicated to ICT for unmatched energy savings
4.0 UPS dedicated to ICT for unmatched energy savings Introducing UPSaver by Borri, a new modular UPS series for the ICT industry, totally configurable, quickly scalable, with high efficiency and low TCO.
Micro Data Center IT protection in the smallest possible space
Micro Data Center IT protection in the smallest possible space 2 Rittal Micro Data Center The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have bundled
How To Make A Fronius Cl Power Inverter
Fronius CL PV central inverter with Fronius MIX concept Modular system. Maximum yield. The Fronius CL combines high-yield power electronics with the unique, modular system design of up to 15 identical
How To Power A Bladecenter H Servers
Solutions Guide for IBM Data Center Architecture: IBM BladeCenter H Servers In today s high-demand enterprise environment, organizations need a reliable infrastructure to run compute-intensive applications
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Secure your IT equipment with confidence... secure with NetClosure
Secure your IT equipment with confidence... secure with NetClosure SERVER CABINETS NetClosure s REM Series Server Cabinet is the ultimate solution designed and engineered for demanding data center environments.
Technical Data. back-up time in minutes 100% load 6 7 0 5 6 0 5 0 50% load 15 18 0 15 16 0 15 0
The protectoq is a On-Line double conversion UPS-system according to IEC / EN 62040-3 (VFI-SS-111) with sinus wave output voltage in each operation mode, LCDindication, RS232 interface, USB-connection,
Eaton 93PM UPS Where aesthetics meet intelligence.
Brochure 100 kw Eaton 93PM UPS Where aesthetics meet intelligence. 93PM features and benefits The Eaton 93PM UPS combines unprecedented and reliability with eye-catching design. A space-saving, flexible
How do I... POPS Smart & Switched CDU. If you manage a datacenter, we have a solution for you.
POPS Smart & Switched CDU Zero-U & Rack Mounted CDUs with Per Outlet Power Sensing If you manage a datacenter, we have a solution for you. How do I... Monitor current, voltage, power (kw), apparent power,
Low Voltage Switchboards The Best Technical Solution for Your Ship
The Best Technical Solution for Your Ship Wärtsilä SAM Electronics Optimal Power Distribution The uninterrupted supply of power to systems and consumers onboard modern ships is an extremly important matter.
ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA
MRO Modularne Razdelilne Omare d.o.o. ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 2, 000 Ljubljana, LOVENIA MC GENERAL When to use? MC - modular switchgear cabinets are type-tested, factory built switchgears,
QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA - 12859 North America Version 5 August 22, 2008 Page 1
Overview It's getting harder to manage a data center efficiently, with rising utility bills and ever-increasing demands due to processor power and server density increases. Growing user requests mean heavier
Galleon 6-10K Online UPS. Voltronic Power Technology Corporation
Galleon 6-10K Online UPS Voltronic Power Technology Corporation Features Galleon online UPS series delivers optimal power quality, provides superior power management, resolves utility power protection
DATA CENTER SOLUTIONS
DATA CENTER SOLUTIONS Nobody Makes Better Data Center Equipment Maximize availability, manageability and efficiency with cost-effective solutions from a dependable partner. Provide reliable, efficient
PRODUCT PRESENTATION PROTECT B.PRO YEAR 2013 NOVEMBER 2012 DATA & IT, SBU C-UPS, PM/SR
PRODUCT PRESENTATION PROTECT B.PRO YEAR 2013 NOVEMBER 2012 DATA & IT, SBU C-UPS, PM/SR CLASSIFICATION CLASSIFICATION ACC. TO - AEG S UPS PRODUCT PORTFOLIO - IT S APPLICATION ORIENTED USE - UPS PRODUCT
LIBRA USV-Anlagen von EBT (10-800KVA) LIBRA pro. UPS 10-100 kva three-phase / single-phase 10-800 kva three-phase / three-phase.
LIBRA USV-Anlagen von EBT (10-800KVA) LIBRA pro online UPS 10-100 kva three-phase / single-phase 10-800 kva three-phase / three-phase LOCAL AREA NETWORKS (LAN) INTERNET CENTERS (ISP/ASP/POP) ELECTRO-MEDICAL
ADC-APC Integrated Cisco Data Center Solutions
Advanced Infrastructure Solution for Cisco Data Center 3.0 Ordering Guide ADC-APC Integrated Cisco Data Center Solutions The evolution of data centers is happening before our eyes. This is due to the
EN The Tool for Tools
EN The Tool for Tools THE TOOL FOR TOOLS Our Toolbase Tool Dispensing System is as reliable as it is multifunctional. Inventory tool management and issuing tools using Toolbase are guaranteed to increase
Make IT easy: The new TS IT rack
Make IT easy: The new TS IT rack The new TS IT rack. A new global standard for network and server equipment. At CeBIT 202, Rittal unveiled a newly developed rack system which is set to redefine the global
19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.
19" Data Racks Attractive design and high quality are characteristic. Basic framework is welded from multiple bent metal plate, which assures great rigidity suitable for heavier equipment. All profile
Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC
TM 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM D400E Data Module (60Hz) The EDGE D400E is designed to meet high power density requirements for both the HPC and Web Scale environments while
Open Rack Hardware v1.0
Open Rack Hardware v1.0 Authors: Pierluigi Sarti, System Designer Steve Mills, Mechanical Engineer 1 Scope This document describes the technical specifications for the custom rack that houses Open Compute
DCF Optimized Rack System Selection Guide
DCF Optimized Rack System Selection Guide DCF Optimized Rack System: Optimized Design, Optimized Delivery, Optimized Value A Rack System Designed to Meet The Challenges Your Data Center Faces Today Your
Customized Server Cabinets
GOING GREEN WITH CUSTOMIZABLE CABINETS AND RACKS Designed to provide industry leading airflow, CyrusOne s cabinets and rack solutions promote optimal cooling and contribute to reduced power consumption.
IPSIP M series-m Modular Data Center
IPSIP M series-m Modular Data Center IPSIP MODULAR TECHNOLOGIES. 1 With the rapid development of cloud computing and mobile Internet businesses, the growth of IT density and energy consumption are bringing
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire
SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire MODEL NUMBER: SU6000RT3UHV Highlights 6000VA / 6kVA / 4200W on-line double-conversion
HP UPS R1500 Generation 3
HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications
7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America
7 Best Practices for Increasing Efficiency, Availability and Capacity XXXX XXXXXXXX Liebert North America Emerson Network Power: The global leader in enabling Business-Critical Continuity Automatic Transfer
RIELLO ELETTRONICA. Master HP
RIELLO ELETTRONICA Master HP LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTRES TELECOM- MUNICATIONS DEVICES E-BUSINESS (Servers Farms, ISP/ASP/POP) INDUSTRIAL PROCESSES INDUSTRIAL PLCS ELECTRO- MEDICAL DEVICES
Racks & Enclosures. Deliver. Design. Define. Three simple words that clearly describe how we approach a Data Center project.
Three simple words that clearly describe how we approach a Data Center project. Eclipse Racks & Enclosures DELIVERING THE RIGHT INFRASTRUCTURE FOR YOUR MISSION-CRITICAL NEEDS SERVER RACKS & NETWORKING
Knürr Smaract. Knürr Smaract. CompactRack
CompactRack Features Ample space for components and cabling provided in an efficient, compact design. The innovative frame concept with triangular extrusions ensures low weight while maintaining high stability.
Miracel 19 rack platform for data center, telecommunication and network technology. Rack & Integrated Enclosure Systems
Miracel 19 rack platform for data center, telecommunication and network technology Rack & Integrated Enclosure Systems The Miracel innovation rack multi-talented, distinguished, integrative The Miracel
T1 Backhaul Connectivity Solution All Products :: Application Note
Telect 1 RU Customer Interface Panel (CIP) Enables Demarcation, Remote Circuit Maintenance and Trouble Isolation at the Backhaul Node The Application: T1 Demarcation and Testing in Backhaul Environments
Model #: SMART2200CRMXL
Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: +(773) 869 1234 E-mail: [email protected] Model #: SMART2200CRMXL SmartPro Compact Rackmount UPS System - Precision Protection for
Galaxy VM. Three-phase power protection. schneider-electric.com
Galaxy VM Three-phase power protection schneider-electric.com 2 schneider-electric.com schneider-electric.com 3 Galaxy VM trusted partner for your business continuity Features and benefits Highly efficient,
Incubator with mechanical convection
BF series 400 Incubators and cooling incubators Incubator with mechanical convection The BINDER incubator of the BF series with mechanical convection is suitable for all gentle incubation applications,
Edition Perfect combination 9 Power supplies Electronic P Edition kaging www clear order..biz information in the catalogue
9 Power supplies Übersicht PROLINE Overview... 0 Power supplies Cabinets... 1 Wall mounted cases... 2 slimpower AC/DC switched-mode power supply 42 W, 3 HP Compact and low interference Accessories for
Power Distribution Considerations for Data Center Racks
Power Distribution Considerations for Data Center Racks Power Distribution Considerations for Data Center Racks Table of Contents 3 Overview 4 At what voltage do you run all the IT equipment? 4 What electrical
06 / 2003. Optional components. MAXDATA PLATINUM Server-Rack PLATINUM. [Product Guide] www.maxdata.de
D Positioning Key-Features Specifications Optional components MAXDATA PLATINUM Server-Rack PLATINUM [Product Guide] www.maxdata.de Positioning Description Server-Racks with 41U, 37U and 23U Highlights
Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments
Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Model #: SM2000RMX Heavy-duty, industrial-grade metal housings Shock and vibration rated to MIL-STD-810D 19 inch
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
The Intelligent AX1 Switchgear for Medium Voltage
The Intelligent AX1 Switchgear for Medium Voltage Leif Lundin, Manager of Research and Development, Division Medium Voltage and Compact Substations, ABB Distribution, Sweden Abstract The newly launched
Server Technology, Inc.
Server Technology, Inc. Cabinet Power Monitoring, Management & Control Within the Data Center White Paper STI-100-011 2010-Sept-27 by Calvin Nicholson, Senior Director Software and Strategic Alliances,
Knürr Miracel. Knürr Miracel. 19 Network and Server Rack Platform 1.12 to 1.22 1.11
Knürr Miracel 19 Network and Server Rack Platform 1.12 to 1.22 1.11 19" Server Rack: Knürr Miracel Strong points 1.13 Knürr Miracel ASP ASP/Server Rack 1.16 Knürr Miracel Server Rack 1.18 Knürr Miracel
Compaq Rack Options and Accessories. Monitors and Keyboards
1 Compaq Rack Options and Accessories Compaq offers a wide variety of rack options and accessories that help you to complete your 9000 and 10000 series racks. Monitors and Keyboards TFT5600RKM United States
NEW RANGE OF CABINETS DRIVIATM. Innovation at your service. THE GLOBAL SPECIALIST in electrical and digital building infrastructures
NEW RANGE OF CABINETS DRIVIATM Innovation at your service THE GLOBAL SPECIALIST in electrical and digital building infrastructures Drivia true innovation The new electrical panel for the residential and
Cisco Redundant Power System 2300
Cisco Redundant Power System 2300 The Cisco Redundant Power System 2300 (RPS 2300) increases availability for converged data, voice, and video networks. The system delivers power supply redundancy and
BLADE S-MAX Cabinet for Blade Server
Cabinet for Blade Server 1 2 Overview Material specification Corner verticals: 1.5 mm steel End frames: 1.5 mm steel Panel mounts: 2.0 mm steel Panel mount supports: 1.5 mm steel Side panels, door and
Distributing Power to Blade Servers
Distributing Power to Blade Servers Ten steps to selecting the optimal power distribution design With the growth in blade servers with dual or triple power supplies, a single rack of equipment can easily
3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
JAWAHARLAL NEHRU UNIVERSITY
School of Biotechnology JAWAHARLAL NEHRU UNIVERSITY New Delhi 110 067 Tender No. JNU/SBT/DBT-BUILDER/Data Centre/2015-16 Sealed Quotation for the establishment of a Data Centre for High-End Computational
GE Consumer & Industrial Power Protection. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva. GE imagination at work
GE Consumer & Industrial Power Protection Digital Energy LP Series UPS Uninterruptible Power Supply 3-30 kva GE imagination at work For more than a century, GE has led the way with innovative technologies
Tyan Computer. Transport PX22. Service Engineer s Manual
Tyan Computer Transport PX22 Service Engineer s Manual 1 Precaution To read through the user manual, check all assembly and follow setup process before any operation on this server To keep paper clips,
Choosing Close-Coupled IT Cooling Solutions
W H I T E P A P E R Choosing Close-Coupled IT Cooling Solutions Smart Strategies for Small to Mid-Size Data Centers Executive Summary As high-density IT equipment becomes the new normal, the amount of
Thyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
Unified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to
RELIABLE AND FLEXIBLE POWER FOR YOUR DATA CENTRE
RELIABLE AND FLEXIBLE POWER FOR YOUR DATA CENTRE Highly efficient solutions for power distribution, management and monitoring POWER DISTRIBUTION WIRE-FREE MONITORING LEAK DETECTION Daxten provides comprehensive
NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements
NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems Safe energy distribution that meets the highest industrial requirements NATUS switchgear systems your advantages minimal use of insulant
Modular architecture for high power UPS systems. A White Paper from the experts in Business-Critical Continuity
Modular architecture for high power UPS systems A White Paper from the experts in Business-Critical Continuity Abstract Today, more than ever before, energy efficiency and cost-savings are among the top
Morgue refrigeration unit
Morgue refrigeration unit The Morgue refrigeration units are made of sturdy, self-supporting walls, floor and ceiling elements. They are delivered in separate components and are to be assembled on site
Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling
Electronics Ltd Presenting Power, Intelligence... with a sense of feeling By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford Plug in slots K772
APC APPLICATION NOTE #112
#112 Best Practices for Deploying the InfraStruXure InRow SC By David Roden Abstract The InfraStruXure InRow SC (ACSC100 and ACSC101) is a self-contained air conditioner for server rooms and wiring closets.
Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009
Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal
DC UPS. RTB.e 50-1000 A. IMB.e/ITB.e 5-200 kva. E2001.e/E3001.e 5-200 kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.
Oil & Gas Energy Catalogue DC UPS RTB.e 50-1000 A 3 phase rectifier battery chargers voltage: 400 Vac, 3-phase, 50/60 Hz voltage: 24/48/110/220 Vdc RMB.e/RCB.e 50-100-150 A 1 and 3 phase compact rectifier