Rittal Data Centre Solutions
|
|
|
- Margaret Flowers
- 9 years ago
- Views:
Transcription
1 issue THREE Rittal Data Centre Solutions RACKS POWER COOLING
2 The simple route to the perfect data centre Data centres are complex systems. Software, hardware and IT infrastructure must work together seamlessly to supply the user with energy and cost efficient, reliable IT services. The IT infrastructure alone demands a wide variety of specialists from each field including: Climate control, power distribution and security. Rittal The System, minimizes complexity and reduces interfaces through one complete, integrated solution. Superior IT performance is achieved through perfect coordination of the RimatriX5 modules: Racks, Power, Cooling, Security, Monitoring & Remote Management, all complimented by a comprehensive range of software and services. Data Centre Solutions presents you with a complete overview of the Rittal IT System. Peter Mellino Managing Director Rittal Australia and New Zealand
3
4 Rittal The System. Faster better worldwide. The requirements placed by a company on its data centre are dependent on a wide range of factors. Regardless of whether a company has a few racks or several hundred servers, every CIO is reliant upon availability and efficiency. Rittal The System. offers a perfectly coordinated platform for this purpose from systematic requirement analysis and planning of the entire data centre, to physical security, through to configuration with precise-fit, efficient IT infrastructure components. This includes robust racks for server and network technology, efficient power supply and protection, and energy-saving climate control components. The system is rounded off by monitoring and security solutions, the RiZone management software, and global customer service. In this way, Rittal offers a product portfolio that is unique on the market, and totally scalable, from the basic solution right through to high-density computing. Rittal The System. Faster better worldwide. Advice Products & solutions Service Scalable Requirement analysis Planning Prime contractor services Racks Cooling Power Monitoring Management software Physical security Customer proximity Global 24 hour spare parts availability Individual maintenance contracts Comprehensive Efficiency Cooling Power Monitoring Complete IT 4
5 Contents Corporate Rack TS8 6 Cooling Racks - High Performance 7 Rack Accessories 8-11 Power Systems 12 Rails - Horizontal & Vertical 1 Intelligent Power Management 14 Modular PSM Power Control Unit Monitored & Controlled Power Units UPS PMC UPS PMC Power Modular Concept 22 UPS PMC UPS Accessories 24 Cooling Systems 26 Aisle Containment 27 CRAC Systems 28 LCP Systems 29-1 Cooling Accessories 1 Security Monitoring 2 - Fire Alarm & Extinguishers 4 RiZone Management 5 Security Rooms 6-7 Data Centre Container 8 Modular Safes 9-40 Notes Literature List 4 PDR Racks 25 Contact Details Back Page 5
6 Corporate Racks - TS8 Corporate Racks - TS8 RACKS The long term performance of an IT infrastructure is dependent on the coordinated interaction of individual components. With RimatriX5 server enclosures, integration of climate control, power and security solutions is simple. Innovative, modular designs maximise internal space and load bearing capacity while making the addition of new active devices and additional enclosures simple and cost effective. Designed specifically for the data centre, the TS8 is a modern enclosure offering strength and stability for virtually any server environment. Its patented 16 fold continuously welded frame delivers 0% more dimensional stability, high load carrying and maximised internal volume. Design Features Robust welded frame structure Front and rear door fully vented; vented surface area > 82% Tool-less adjustment of mounting angles reduces equipment deployment time Vendor neutrality, thanks to infinite adjustment of mounting angles Cable entry via the roof and base 2-piece side panels Static load capacity of up to 1200 kg Castors and levelling feet on each model Material: Mild steel Surface finish: Enclosure frame: Dipcoat primed Enclosure panels: Dipcoat primed, powder-coated RAL 9005 (black) Corporate Rack With Side Panels Supply includes: Enclosure frame TS 8 with mild steel doors front and rear, vented 82% open area, with 10 tooless quick release type hinges, rear door split type, top panel provisioned with 4 covered cable entry points, L-shaped front and rear depth-variable mounting angles each with screen printed RU positions and adjustable via tooless assembly, levelling feet, castor kit, comfort handles with security lock 524 E with push button control, both sides have dual lockable side panels. Model No. Width Height Depth RU Corporate Rack Without Side Panels Supply includes: Enclosure frame TS 8 with mild steel doors front and rear, vented 82% open area, with 10 tooless quick release type hinges, rear door split type, top panel provisioned with 4 covered cable entry points, L-shaped front and rear depth-variable mounting angles each with screen printed RU positions and adjustable via tooless assembly, levelling feet, castor kit, comfort handles with security lock 524 E with push button control, no side panels. Model No. Width Height Depth RU AUS: rimatrix5.com.au NZ: rimatrix5.co.nz
7 High Performance Cooling Racks High Performance Cooling systems HPC: Material: Mild steel Surface finish: Dipcoat-primed, panels additionally powdercoated, RAL 705. Gland plates and mm (19 ) mounting frame zinc-plated, passivated Supply includes: Enclosure frame with doors and rear panel, roof plate, gland plate, mm (19 ) interior installation, earthing of all panels, levelling feet, fitted. Without side panels Model No. DK With side panels Width mm Height mm Depth mm U ) Model No. DK ) Doors Aluminium glazed front door, sheet steel rear door n n n n n Roof Roof plate for cable entry, two-piece n n n n n Base Levelling feet n n n n n Base frame with multi-piece gland plate n n n n n Interior installation mm (19 ) levels front and rear n n n n n L-shaped mounting angles Mounting angles attached to depth stays mm (19 ) mounting frames front and rear n n n n n Panel earthing, fitted n n n n n Accessories Side panel, screw-fastened, IP n ( only) n ( only) Depth-variable slide rail, 1 U, length mm, 80 kg, static, packs of mm (19 ) heavy duty base, 500/700 mm deep, kg load capacity1) Installation kit for heavy-duty component shelf, depth-variable n Included with the supply 1) All sizes are nominal dimensions. For absolute dimensions, please refer to the detailed drawing on the Internet. 2) Delivery times available on request. AUS: rittal.com.au NZ: rittal.co.nz 7
8 RACK ACCESSORIES Rack Accessories Fixed Shelf Application: Can be used with all 19" cabinets Features: Unique minimised hardware fixing system Adjustable mounting position Includes mounting hardware and bracketry Finish: RAL705 Part No. Width x Depth Fits Cabinet L " x 450mm 600 Deep 800 Deep L " x 600mm 800 Deep 1000 Deep L " x 740mm 800 Deep 1000 Deep 1200 Deep Sliding Shelf Application: Can be used with all 19" cabinets Features Adjustable mounting position Includes mounting hardware and bracketry 0kg rating Finish: RAL705 Part No. Width x Depth Fits Cabinet L714450T 19" x 450mm 600 Deep 800 Deep L714600T 19" x 600mm 800 Deep 1000 Deep L714700T 19" x 700mm 800 Deep 1000 Deep 1200 Deep Cantilever Shelf Part No. L Size 1RU 180mm Deep L RU 260mm Deep 8 AUS: rimatrix5.com.au NZ: rimatrix5.co.nz
9 Rack Accessories 19 Blanking Panels Features: Complete with mounting hardware Colour: RAL705 Unit Part No. Height Description L RU 19" Blank Panel 1RU L RU 19" Blank Panel 2RU L RU 19" Blank Panel 5RU L RU 19" Blank Panel 9RU 1U Tool-less Blanking Panels Supply includes: 10 blanking panels with integral quick-fastening Part No. Colour Packs RAL RAL U & 2U Cable Management Ring Panel Can be used with all 19" cabinets Rings can be reorientated All metal construction Part No. Cable Ring Size mm x 7mm mm x 80mm Cable Shunting Rings Application: Cable routing 2 sizes Can be mounted to mounting rails, punched sections and cabinet frame. Part No. Width x Depth mm x 80mm mm x 7mm Part No. Unit Height Width Description Cable Tray Material 1.2 steel construction with vertical slots ideal for hook and clasp cable ties Finish: RAL705 LCT Cable Tray 24RU x 100 wide LCT Cable Tray 42RU x 100 wide LCT Cable Tray 42RU x 00 wide LCT Cable Tray 47RU x 100 wide LCT Cable Tray 47RU x 00 wide AUS: rittal.com.au NZ: rittal.co.nz 9
10 Rack Accessories RACK ACCESSORIES Telescopic Chimney (Cable or Air Duct) Features: Height adjustable from 500mm to 780mm Retro fittable around an existing cable installation Access area cross section 450mm x 140mm Colour: RAL705 Grey (pictured as a black variant) Part No. LCHIMT760 Cage Nuts Features: Each fastener kit consists of a M6 cage nut, screw and nylon washer Available in black Part No. LCNKIT4 LCNKIT50 Description Fastener Kit x 4 (set) Fastener Kit x 50 (set) Baying Kit Used for the fixing together of two frames without side panels All fasteners provided Installation and instruction sheets provided Part No Extension kit for complete earthing kit for DK-TS To DIN EN /VDE 0805, Ø 4 mm2, Imax. 40 A. To extend the complete earthing kit DK , in order to keep additional components potential free. Conductor length 00 mm in each case. For 6. mm flat-pin connectors, 8 mm earthing bolts or for attachment with contact washers and screw. Supply includes: Assembly parts and identification Model Number DK Pack labels set 10 AUS: rimatrix5.com.au NZ: rimatrix5.co.nz
11 Rack Accessories Overhead cable trough Large capacity cable trough Integrated grounding provisions Unique design allows for power and data cables in one trough with the use of cable claws Cable pass-through provisions Accommodates ladder rack installations in parallel and perpendicular configurations Tool-less installation Cable Duct for TS/TE For laying cable in particularly high packaging densities (high density network nodes), in the field of optical fibre or copper cabling. Large capacity. A wide range of cable routing, cable clamping, channelling and cross-cabling options creates the requirements for maximum port density in the minimum possible space. The individual U-related cable routing makes it possible to dispense with additional cable routing via patch panels within the distributor level, thereby equipping every U with connection points. This increases port density by up to 50%. The removable duct cover, hinged on both sides, facilitates user-friendly access at any time. The cable sections are held back by removable crossbars to protect them against falling out. Mounting is either on mounting rails at the sides, or on mounting angles and mounting frames in the mm (19 ) distributor level. Two ducts may also be secured back-to-back. There is a second, smaller variant available for intensive partial installation. Material: Cable duct: Sheet steel, spray-finished Cable routing components: Plastic Front trim panel: Aluminium, spray-finished Colour: RAL 705 Supply includes: Hinged front trim panel. Model Number DK Width mm Height mm No. of U Pack Accessories: Cable ties for spare cables Model Number DK Pack Note: When using the duct in conjunction with mm (19 ) mounting frames and TS 8, the inner mounting level in the vicinity of the cable duct is not available. Within the duct, additional cable holders may be attached to accommodate spare cables and for system-compatible cable deflection. AUS: rittal.com.au NZ: rittal.co.nz 11
12 POWER SYSTEMS Power Systems Miniaturisation and the ever greater performance of hardware components place new demands on modern power management solutions for the data centre. Ever increasing data requirements and the introduction of new devices require scalability and quick implementation of power management systems. With RimatriX5, the need for redundancy, scalability and maximum availability are bundled into a single system. Together, these solutions help to reduce operating costs and boost the availability of the overall system. The RimatriX5 power management and distribution product range is based on implementing plug-and-play expansion, with no need to interrupt current operations. Downtime is avoided and future operating costs are lowered. 12 AUS: rimatrix5.com.au NZ: rimatrix5.co.nz
13 Power Systems - horizontal and vertical rails Horizontal & Vertical Power Rails Features: 10 amp All fixing hardware included Includes m lead 15 amp and 20 amp versions available on request IEC and captive plugs also available on request Colour: RAL 9005 Black Horizontal Features: Mounts to 19" mounting Rails Vertical Features: Mounts to all frame elements Part No. Description Outlets Type 1 Orientation Dimensions mm L x RU X D Plug Type Special Notes Mounting LPQ06AEEBK DK Powerrail 1RU 6 Way GPO 10amp 6 X 10 amp GPO Horizontal 420 x x amp GPO captive 10 amp thermal overload 19 LPQ12AEEBK DK Powerrail 2RU 12 Way GPO 10amp 12 X 10 amp GPO Horizontal 420 x 88.9 x amp GPO captive 10 amp thermal overload 19 LPQ12AEEBKV LPQ21AEEBK DK Powerrail vertical 12 Way GPO 10amp DK Powerrail vertical 21 Way GPO 10amp 12 X 10 amp GPO Vertical 756 x x X 10 amp GPO Vertical 1260 x x amp GPO captive 10 amp GPO captive 10 amp thermal overload 10 amp thermal overload Sliding bracket system Sliding bracket system LPQ06EFEBK DK Powerrail 1RU 6 Way GPO 15amp 6 X 15 amp GPO Horizontal 420 x x amp GPO captive 15 amp thermal overload 19 LPQ12EFEBK DK Powerrail 2RU 12 Way GPO 15amp 12 X 15 amp GPO Horizontal 420 x 88.9 x amp GPO captive 15 amp thermal overload 19 LPQ12EFEBKV DK Powerrail vertical 12 Way GPO 15amp 12 X 15 amp GPO Vertical 756 x x amp GPO captive 15 amp thermal overload Sliding bracket system LPQ21EFEBK DK Powerrail vertical 21 Way GPO 15amp 21 X 15 amp GPO Vertical 1260 x x amp GPO captive 15 amp thermal overload Sliding bracket system Hybrid IEC Power Rails Part No. Description Outlets Type 1 Outlets Type 2 Orientation Dimensions mm L x RU X D Plug Type Special Notes Mounting LPRHYBRID00 TE POWERRAIL Hybrid 16 WAY IEC 15amp 12 X 10 AMP C1 IEC 4 X 16 AMP C19 IEC Vertical 1260 x x amp GPO captive LED indicator side or top bottom fixed + hang style from buttons LPRHYBRID006 TE POWERRAIL Hybrid 24 WAY IEC 15amp 20 X 10 AMP C1 IEC 4 X 16 AMP C19 IEC Vertical 1260 x x amp GPO captive LED indicator side or top bottom fixed + hang style from buttons LPRHYBRID004 TE POWERRAIL Hybrid 24 WAY IEC 20amp 20 X 10 AMP C1 IEC 4 X 16 AMP C19 IEC Vertical 1260 x x amp GPO captive LED indicator side or top bottom fixed + hang style from buttons AUS: rittal.com.au NZ: rittal.co.nz 1
14 POWER SYSTEMS Power Systems - Module PSM/Power Control Unit PCU Intelligent power management with the Rittal PSM/PCU system Switching and measuring at individual server level During times of rising energy costs, operators need to be very aware of the performance data of their hardware. With this in mind, Rittal has extended its range of active PSM modules with switching option to include the feature of current measurement per outlet slot. This supports targeted data logging and response down to individual equipment level. With the new active modules, which are compatible with existing PSM modules, it is now possible to monitor the current power consumptionof individual servers and peripheral hardware at a glance. The respective outgoing output is displayed visually via two LEDs per slot based on the traffic light principle (green, amber, red). Additionally, the overall current of the module can be read from a 7-segment display in the upper area of the module. The individual slot limits may be retrieved online via the CMC-TC system. An upper limit for the entire module may also be set. Once this is reached, all LEDs on the active module switch to red so that no further equipment is connected. Networking capability of active modules via the CMC-TC system In conjunction with the Rittal CMC-TC Processing Unit II, up to 16 active PSM/PCU modules may be managed via TCP/IP. Event-controlled linking e.g. of switching states with other CMC-TC sensors (e.g. temperature) is also supported. Connection recommendations: In order to ensure problem-free operation and the maximum connected load (22 kw) of the PSM bar, it is essential to ensure that a separate circuit with 16 A fuse is allocated to each module installed in the PSM bar (this is possible with 2 x three-phase 16 A infeed to the PSM bar by refraining from populating the 7th (8th) slot). For active PSM/PCU modules that are controlled via the CMC-TC system, the default values of the output ranges may be modified. These limits may be adapted to the respective equipment environment. The values may be configured here in 0.1 A increments up to 10 A (15 A) via the CMC-TC web interface! Note: Detailed information on the supply scope of the Rittal PSM system may be found in the IT Catalogue, from page 99. Further information on the CMC-TC may be found in the IT Catalogue, from page 15. Note: The limits of the visual display may be set to customer-specific requirements via the CMC-TC system. If an upper limit has been set for the overall output of the module and this limit is reached, all LEDs on the module will automatically switch to red. Green LEDs indicate that power is being supplied to the PSM module, and a low current flow of between 0.1A and 7A has been detected on the slot of that module. Other equipment may now be safely connected. Amber LEDs indicate an increased current flow of between 7A and 1A on the slot. The power consumption of all equipment connected to the module must not exceed 000 W. Before connecting other equipment, please note its connected load. Red LEDs indicate that the threshold of 1A has been exceeded. No further equipment must be connected in order to avoid overloading and tripping of the prefuses. 14 AUS: rimatrix5.com.au NZ: rimatrix5.co.nz
15 Power Systems - Module PSM/Power Control Unit PCU PSM/PCU modules in conjunction with the CMC-TC Common features: 2-digit local LED 7-segment current display. Individual current measurement per slot with limit configuration via CMC-TC web interface. LED colour code for fast load assessment per module, and (new): per slot. SNMP switching option via the network. Up to 16 modules via a joint web interface under one IP address (up to 4 modules of the same type per port). Measuring and monitoring of the current per module and outgoing slot. Limits (range limits, signalling via coloured LED) may be freely configured. The 8/41) individual slots of the module may be switched separately in conjunction with the CMC-TC. May also be linked to other CMC-TC alarm messages. Alarm messages are additionally indicated byflashing LEDs. Up to 16 modules may be administered with one CMC-TC system via a shared IP address. Also required: CMC-TC Processing Unit II, DK wide-range power pack (sec. 24 V DC), DK U mounting unit, DK Connection cable (Cat 5), DK CMC-TC programming cable, DK Connection cable (DE) 20 V AC, DK ) There are additionally 2 x IEC C1 slots (IEC 20 connection) available per module. Plug-in modules active PSM with individual current measurement (IP-compatible in conjunction with CMC-TC) Module with 8/4 1 ) slots, individually switchable or logging of individual currents per outgoing slot (C1/C19) via the Rittal CMC-TC. These active, switchable modules each occupy 2 slots in the PSM bar, and therefore, up to (2) modules may be installed in a PSM busbar for 2000 mm (1200 mm) high racks. Combined population of different modules is also supported. A maximum of 16 modules may be administered via one IP address. Material: Aluminium section with black plastic cover Supply includes: PSM plug-in module, instructions, bus cable. Note: Operating the module without CMC-TC (local current display in the rack) For operation of the socket strip, power pack DK and a mains cable (country-specific) is required. Up to 4 modules may be operated with one power pack. However, configuration of the individual limits is only possible via the CMC-TC. A PSM busbar is required to operate. 1) There are additionally 2 x IEC C1 slots (IEC 20 connection) available. Model Number DK Plug-in module Number of slots IEC C IEC C ) Rittal Power Control Unit with individual current measurement (PCU, IP-compatible in conjunction with CMC-TC) Module with 8/4 1 ) slots, individually switchable or logging of individual currents per outgoing slot (C1/C19) via the Rittal CMC-TC. This module may be mounted both within the mm (19 ) level and on the enclosure frame (zero-u). Material: Aluminium section with black plastic cover Supply includes: PCU mm (19 ) module, bus cable, instructions, assembly parts for mm (19 ) installation, connector. Note: Operating the PCU without CMC-TC (local current display in the rack) For operation of the socket strip, power pack DK and a mains cable (country-specific) are required. Up to 4 modules may be operated with one power pack. However, configuration of the individual limits Number is only possible via the CMC-TC. Model Number DK Plug-in module of slots 1) There are additionally 2 x IEC C1 slots (IEC 20 connection) available per module IEC C IEC C ) AUS: rittal.com.au NZ: rittal.co.nz 15
16 Power Systems - Module PSM POWER SYSTEMS PSM busbar with fixed infeed, -phase Busbar with fixed connection cable for strain relief. The existing DIN screw fastening prevents the cable from being pulled out accidentally. Connection is made using a m connection cable with open cable ends. Supply includes: Busbar with fixed connection cable, assembly instructions, assembly parts. Also required: PSM plug-in modules, see IT Catalogue, page Model Number DK For enclosure height mm Power Supply Maximum no. of modules x 16A x x 16A 7 PSM busbar for 47 U rack, -phase PSM busbar in special versions for 47 U racks. The 2100 mm high busbar offers 8 slots for PSM modules. Technical specifications: -phase infeed construction with a maximum current of x 16 A A redundant three-phase infeed with x 16 A may also be added The redundant circuit is completely separate from the phases of the support rail Supply includes: Busbar, assembly instructions, assembly parts. Without cable. Also required: Connection cable, PSM plug-in modules, see IT Catalogue, page Model Number DK For enclosure height mm Power Supply Maximum no. of modules x x 16A 8 PSM busbar with measurement Single-phase, 2 A Busbar with integral output measurement to display and monitor the entire connected current of the PSM bar. The display is local. The bar is remotely administrable and configurable in conjunction with the CMC-TC system. The following active functions are provided: Local display Measurement and monitoring of the current and voltage. Adjustable limits. Measurement range 0 16 A/0 250 V Alarm notifications via a flashing display Remote administration of the bar supported (in conjunction with the CMC-TC) Supply includes: Busbar with fixed connection cable,with CE connector (2 A), instructions, assembly parts. Note: In stand-alone mode without CMC-TC, a separate power pack DK with connection cables is required. Also required: PSM plug-in modules, see IT Catalogue, page , CMC-TC system, see IT Catalogue, from page 15. Model Number DK For enclosure height mm Power Supply Maximum no. of modules x 2A 6 16 AUS: rimatrix5.com.au NZ: rimatrix5.co.nz
17 Power Systems - Module PSM PSM busbar with fixed infeed/rcd Busbar with Residual Current protective Device (RCD). The busbar is protected against inadmissibly high touch voltages by two RCDs with a rated differential current of 0 ma. One RCD protects slots on the bar. Additionally, there are two 16 A miniature circuit-breakers integrated into the bar. Infeed is via a 2 A CE connector. Supply includes: Busbar with m fixed connection cable, instructions, assembly parts. Also required: Plug-in module PSM, Model Number DK For enclosure height mm Power Supply Maximum no. of modules x 2A 6 PSM plug-in module with integral RCD PSM module with integral RCD. The rated differential current of the RCD is 0 ma. The module occupies 2 module slots on the PSM bar. Model Number DK Plug-in module Number of sockets EC C1 8 x 1C AUS: rittal.com.au NZ: rittal.co.nz 17
18 MONITORED AND CONTROLLED POWER RAILS Monitored and Controlled Power Rails Cabinet PDUs explained These Rails provide AC and DC Cabinet Power Distribution Units as well as a full line of Fail Safe Transfer Switches. These devices manage everything from basic power distribution and load current monitoring to secure remote access, management and control of the power and network devices within a data centre equipment cabinet Features of these product include LED digital display indicator, IP based remote power management, ability to view power, temperature and humidity levels & receive SNMP-based alarms when conditions exceed defined thresholds Product offers ranging from Combine Power Distribution with the ability to monitor network equipment power draws. Each Metered Cabinet Power Distribution Unit's (PDUs) LED digital display indicator provides an accurate, real-time reading of the aggregate power load in amps on each power circuit in the rack. (Metered) Control network access to remote sites and data centre equipment with IP-based remote power management (switched) Data centre managers need solutions such as Sentry Switch POPS (Outlet Power Sensing) units that monitor, track and manage servers and IT equipment and the equipment cabinet infrastructure that houses them. (pops) Use the network interface via Web browser, or receive SNMP-based alarms when conditions exceed defined thresholds. (Smart) Smart CDU The Smart Cabinet Distribution Unit (CDU) provides reliable power distribution combined with local and networked power monitoring and environmental montoring* via IP. Use the network interface to view power, temperature and humity levels via Web browser, or receive SNMP based alarms and alerts when conditions exceed defined thresholds. Switched CDU The Switched Cabinet Distribution Units (CDU) family combines network configuration and management with power distribution, power and environmental monitoring. Reboot a single or dual power server with one command and receive SNMP or based alerts when power or environmental conditions exceed thresholds. Assign users specific access rights to designated outlets or groups. Sentry: POPS Switched CDU Cabinet Power Distribution Unit with Per Outlet Power Sensing Sentry POPS (Per Outlet Power Sensing) combines all the features and functions of a Switched CDU with the ability to provide power monitoring per an individual outlet/device includes current, voltage, power (kw) apparent power, crest factor and power factor. Using our grouping technology, power information is available per device, groups of devices (application), individual CDU or cabinet. Sentry Power Manager - Manage multiple CDU s across multiple locations Do you have multiple Sentry CDU s in one or more locations that you would like to access from one central point? Would you like one central location where all alarms can be viewed and logged for reporting, or SNMP trap notifications? No problem! Our Sentry Power Manager (SPM) product is capable of monitoring and managing mutiple Sentry devices in IP based enterprise networks. SPM provides a global view of all Sentry CDU s with the ability to view devices based on their temperature, humidity, current and device status. Besides managing and monitoring all alarm conditions, this information can also be used to provide reporting and tending informatin for display within SPM or integrated with your existing Building Management System (BMS). 18 AUS: rimatrix5.com.au NZ: rimatrix5.co.nz
19 Monitored and Controlled Power Rails Smart Part No. CS-16VE-P2M CS-24VE-P2MA CL-16VE-P2M CL-24VE-P2MA Web addressable monitoring, local current meter, Branch Circuit Protection on various models, temperature/ humidity support Smart CDU, 0U, 16 x IEC C1 Outlets, LED amp meter, 20V 2A input w/ IEC A connector & cord, 10 ft (m) w/ 2 x Temp/Humid Capable, with retractable fuses Smart CDU, 0U, 18 x IEC C1 Outlets, 6 x IEC C19 Outlets, x LED amp meters, 20V input w/ IEC A connector and cord 10ft (m), 2 x Temp/Humid Capable, with retractable fuses Smart CDU (Expansion Unit), 0U, 16 x IEC C1 Outlets, LED amp meter, 20V 2A input w/ IEC A connector & cord, 10 (m), with retractable fuses Smart CDU (Expansion Unit), 0U, 18 x IEC C1 Outlets, 6 x IEC C19 Outlets, x LED amp meters, 20V input w/ IEC A connector and cord 10ft (m), with retractable fuses Switched Part No. CW-16VE-P2M CW-24VEK11A1 CX-16VE-P2M CX-24VEK11A1 Switched POPS Part No. CWG-24VEK11A1 CXG-24VEK11A1 Sentry Power Manager (SPM) Part No. SPM-APP SPM-25 SPM-50 SPM-100 SPM1-25 SPM1-50 SPM1-100 Web addressable monitoring and control, individual outlet reboot, local current meter and Branch Circuit Protection on various models, temperature/humidity support Switched CDU, 0U, 16 x IEC C1 Outlets, LED amp meter, 20V 2A input w/ IEC 6009 connector & cord, 10ft (m), 2 x Temp/Humid Capable, with retractable fuses Switched CDU, 0U, 18 x IEC C1 Outlets and 6 x IEC C19 Outlets, x LED Amp Meters, 20V 2A Input w/ IEC 6009 Connector, Bottom/Front Cord Entry, m (10_x0019_) Cord, 2 x Temp/Humid Capable, with Retractable Fuses Switched CDU (Expansion Unit), 0U, 16 x IEC C1 Outlets, LED amp meter, 20V 2A input w/ IEC 6009 connector & cord, 10ft (m), with retractable fuses Switched CDU (Expansion Unit), 0U, 18 x IEC C1 Outlets and 6 x IEC C19 Outlets, x LED Amp Meters, 20V 2A Input w/ IEC 6009 Connector, Bottom/Front Cord Entry, m (10 ) Cord, with Retractable Fuses Switched POPS (Per Outlet Power Sensing) provide power monitoring at the outlet level, Web addressable monitoring and control, individual outlet reboot, local current meter and Branch Circuit Protection on various models, temperature/humidity support Switched POPS CDU, Per Outlet Power Sensing, 0U, 18 x IEC C1, 6 x IEC C19, x LED Amp Meters, 20V 2A w/ IEC 6009 Connector and Cord, Bottom/Front Entry, m (10ft) Cord, 2 x Temp/Humid Capable, w/ Retractable Fuses Switched POPS CDU (Expansion Unit), Per Outlet Power Sensing, 0U, 18 x IEC C1, 6 x IEC C19, x LED Amp Meters, 20V 2A w/ IEC 6009 Connector and Cord, Bottom/Front Entry, m (10ft) Cord, w/ Retractable Fuses Monitor and manage multiple CDUs in one or multiple locations Sentry Power Manager - Hardware appliance. Required for SPM node license(s). Hardware includes 2-year warranty. Sentry Power Manager - 25 node license, requires support contract Sentry Power Manager - 50 node license, requires support contract Sentry Power Manager node license, requires support contract Sentry Power Manager 25 Node - 1 year service contract, S/W updates Sentry Power Manager 50 Node - 1 year service contract, S/W updates Sentry Power Manager 100 Node - 1 year service contract, S/W updates Environmental Monitors Part No. EMTH-1-1 Combination Temperature & Humidity Probe, 10 ft ( m) EMWS-1-1 Water Sense Probe - 15 feet (4.5 m) AUS: rittal.com.au NZ: rittal.co.nz 19
20 UPS PMC 12 - single phase, output range 1-12kVA n+1 SINGLE PHASE UPS The UPS is distinguished by the use of double-conversion technology. Double-conversion technology provides the basis for an optimum supply voltage to all connected loads. This makes the Rittal PMC 12 UPS ideally suited for all applications in the IT environment and for other requirements such as automation technology, system control etc. A scalable autonomy of up to 55 minutes at 100% load produces a broad application spectrum. With 90º swivellable LCD Serial/USB interface and emergency power off (EPO) contact Optional SNMP monitoring card Batteries hot swap compatible, may be replaced from the front Integral batteries for 1-kVA external batteries for 4.5kVA and 6kVA Parallel switching of 4.5kVA and 6kVA UPS modules up to 12kVA n+1 redundant Autonomy (min.) at 100% load: UPS type in Battery packs supplied state kva 7 min. 28 min. 55 min. 2 kva 7 min. 17 min. 29 min. kva 5 min. 12 min. 20 min. 4.5 kva 9 min. 2 min. 9 min. 6 kva 8 min. 20 min. min. Supply includes: DK , DK , DK Single-phase UPS systems with internal hot-swap compatible batteries, assembly parts, operating manual, software on CD-ROM, USB, RS22 cable and earthing-pin connection cable. Supply includes: DK , DK Single-phase UPS systems with assembly parts, operating manual, software on CD-ROM, RS22 cable and connection cable with open cable ends. UPS for mm (19) racks or as floor-standing enclosures UPS with integral battery UPS control unit Model No. DK PMC 12, 2 U Width x height mm 440 (482.6 mm/19 ) x 88 (2 U) Depth 2) mm Weight kg Model No. DK PMC 12, 4 U Width x height mm 440 (482.6 mm/19 ) x 176 (4 U) Depth 2) mm Weight kg VA Power Watts Max. heat loss (W) Rated voltage 20 V ( V) Input Frequency 50/60 Hz ±5% Power factor > 0.99 with linear load Voltage 20 V < ±1% (200/208/220/20/240 V adjustable) Output Frequency, synchronised ± 1 Hz Operating ratio, AC mode 88% 88% 90% 90% 90% Power factor 0.8 Battery 5 years EUROBAT Autonomy at 100% load > 7 min. > 7 min. > 5 min. > 12 min. 1) > 8 min. 1) Interface 1 x USB, 1 x RS22 1 x RS22 Communication SNMP Optional network monitoring card DK /relay card Operating systems supported Windows, Unix, Linux, OS/2, Novell, Apple; RCCMD shutdown licence DK Emergency Power Off (EPO) Connection Input connection 20 V Output connection 20 V 10 A C14 6 x 10 A, C1, 2 units switched 16 A C20 4 x 10 A, C1, 2 units switched, 1 x 16 A, C19 Compact connector Compact connector Compact connector Compact connector Power IEC/EN Standards and certifications EMC EN /EN class A, EN /-/-4/-6-8/-11, EN /- Labelling CE, FCC Accessories Battery pack ) PMC Battery pack PMC 12 compact Connection cable at output end, UPS, single-phase, for PSM busbar ) With an external battery pack 2) Without an external battery pack ) Autonomy (min.) at 100% load see table. 20 AUS: rimatrix5.com.au NZ: rimatrix5.co.nz
21 UPS PMC 40 - phase, output range scalable kw 11 HE 15 HE 18 HE 26 HE UPS -PH Type 1 Type 2 Type Type 4 PMC 40 compact rack independent UPS system (up to 40 kw, -phase) This uses double conversion UPS technology according to the highest classification VFI-SS-111, which provides a constant output irrespective of the incoming voltage, coupled with a high overall operating ratio and minimal space requirements. The PMC 40 may be configured as a redundant system. As a general principle, it is important to ensure adequate climate control of the rack where the PMC 40 is installed. For installation purposes, the rack must have two mm (19 ) mounting levels and a minimum depth of 800 mm. Depending on the configuration, mixed population (e.g. with servers) in the same rack is also supported. The PMC 40 (redundant design) has safe swap capabilities. This allows easy, safe module exchange while the system is operational, without having to switch the UPS to bypass mode. Supply includes: A PMC 40 UPS system is comprised of a basic unit for mm (19 ) installation. 1 2 UPS modules and, depending on the version, a maximum of two battery packs per UPS module may be integrated into this basic module. The configured complete system comes supplied with basic unit and UPS module(s). The battery packs are supplied separately. Type 1 Type 2 Type Type 4 Number of UPS modules Number of battery packs Maximum UPS output (with 10 kw/20 kw module) kw 10 10/ /40 UPS output with 1+1 redundancy (with 10 kw/20 kw module) kw 10 10/20 Approx. autonomies at 100% load (10 kw/20 kw modules) min. 6/ 15/5 6/ 16/5 Approx. autonomies at 50% load (10 kw/20 kw modules) min. 12/ 0/10 12/ 2/10 Qty. 1/1 1/1 1/1 1/1 Width (B) mm 485 (19 ) 485 (19 ) 485 (19 ) 485 (19 ) Dimensions Height (H) U Depth (T) mm Required distance between mm (19 ) levels (min./max.) mm Weight (approx. incl. batteries and UPS modules) kg Model No. DK basic unit Model No. DK PMC kw module (order quantity acc. to type) Model No. DK PMC kw module (order quantity acc. to type) Model No. DK PMC 40 battery pack per n x 4 x 10 batteries (12 V/7 Ah) prewired (service life 5 acc. to EUROBAT) n = 1, 2, 4 Model No. DK PMC 40 battery preparation (for export or air freight ) Drawers and battery cabling (excluding battery, quantity depending on type) 1 x x x x x x Accessories SNMP monitoring card (Budget) RCCMD licence, bundle with 5 licences for selective shutdown of computers (only available in conjunction with UPS hardware) RCCMD licence, bundle with 25 licences for selective shutdown of computers (only available in conjunction with UPS hardware) Note: Only UPS modules with an identical output may be combined. AUS: rittal.com.au NZ: rittal.co.nz 21
22 UPS Power Modular Concept UPS -PH Rittal UPS Power Modular Concept 1 Rittal PMC 200 ensures optimum availability for critical applications by combining modularity (flexible, unlimited scalability and redundancy, whereby up to 20 modules may be switched in parallel) with decentralised parallel architecture or DPA (redundant protection without a single point of failure ). The UPS modules are transformerless, genuine online, double-conversion UPSs with static bypass and classification code VFI-SS-111. This modular concept keeps the purchasing and operating costs of redundant solutions exceptionally low. As your performance requirements grow, the UPS grows with you, thanks to its flexible scalability even in the most confined spaces, and with the system operational. The benefits to you: Pay as you grow approach, minimising CAPEX whilst retaining flexibility for the future Highest levels of availability thanks to short MTTR and long MTBF Rightsizing of UPS provides better efficiencies for redundancy Safe swap technology enables modules to be removed or added without any downtime High efficiency even at low loads No single point of failure in overall architecture No de-rating of UPS with leading power factors up to 0.9 Module range (per rack) Up to 100 kw Up to 200 kw Module power kw Rectifier data Nominal input voltage Input voltage tolerance V V x 80/220 V+N, x 400/20 V+N, x 415/240 V+N x 06/177 V to x 464/264 V for < 100% load x 280/161 V to x 464/264 V for < 80% load x 160/18 V to x 464/264 V for < 60% load 5 70 Input frequency Hz Power factor input PF = % load Distortion factor, THDI Sine-wave THDI = < % 100% load 2. Battery specifications (maintenance-free lead and NiCd) No. of 12 V batteries Battery charging curve Ripple free; IU (DIN 41 77) Output data Power output per module Output power per module at cos phi 0.8 ind. to cos phi 0.9 cap. Output voltage Operating ratio AC AC at 100%/75%/50%/25% load (cos phi 1.0) Eco-mode operating ratio at 100% load kva kw V % % 25 0 x 80/220 V or x 400/20 V or x 415/240 V 96/95/95/ General technical specifications Safety EN : 200, EN : 2006 EMC 2006, EN : 2000, EN : 2006, EN : 2006, EN : 2002 EN : 2002 Product conformity CE Protection category IP 20 Noise level at 100%/50% load db (A) 55/49 57/49 57/49 57/49 59/51 6/5 Up to 20 modules 6/5 22 AUS: rimatrix5.com.au NZ: rimatrix5.co.nz
23 UPS PMC phase, output range scalable 8-800kW Part No. PMC200 -Ph UPS PMC PMC PMC PMC PMC200 Module 10kVA / 8kW PMC200 Module 15kVA / 12kW PMC200 Module 20kVA / 16kW PMC200 Module 25kVA / 20kW PMC200 Module 0kVA / 24kW PMC200 Module 40kVA / 2kW PMC200 Module 45kVA / 40kW Trays and Links for PMC Trays and Links for PMC Battery Rack (800x2000x1000) max.150 Batt. - common Battery Rack (600x2000x1000) max.120 Batt. - common Battery Rack (600x2000x1000) max.120 Batt. - separate Battery Rack (800x2000x1000) max.150 Batt. - separate Trays for Battery Rack / Links (Cables) for Battery Rack / Trays for Battery Rack / Links (Cables) for Battery Rack / Battery string 7Ah (10 Batteries) Battery string 28Ah (10 Batteries) Parallel cable kit for linking 2 PMC200 racks Sub-distributor with 12 -ph outlets - 16A SNMP Card RCCMD License (Win-NT, UNIX, Novell) - 25 users A safe investment almost unlimited scalability Up to 20 PMC modules may be gradually switched in parallel e.g. in order to supply 800 kw without redundancy or 760 kw n+1 (with 40 kw modules) uninterrupted. May be upgraded with the system operational; no need to switch over to an unprotected network Examples of 12 and 20 kw module configurations and autonomies UPS racks: Battery racks: W 600 x H 2000 x D 1000 mm W 600 x H 2000 x D 1000 mm Redundancy UPS rack/battery rack Number of UPS modules without 1/ 1 with PMC 12 module type, power in kw Battery autonomy 1) PMC 20 module type, power in kw Battery autonomy 1) without 1/ 2 with 1/ 2 without 1/ with 1/ without 1/1 4 with 1/1 4 without 1/1 5 with 1/1 5 Note: This table contains only sample configurations. We would be pleased to configure your individual solution with you. AUS: rittal.com.au NZ: rittal.co.nz 2
24 UPS Accessories UPS ACCESSORIES Mechanical maintenance bypass, 2 U for PMC 12 Facilitates uninterrupted removal/maintenance of the UPS. Various designs are required depending on the UPS output category. Connection of the bypass for 1 kva UPS models is via a connector (Plug & Play), while the 4.5 and 6 kva UPS variant must be installed by a qualified electrician. It is important to ensure the correct prefuse of the UPS bypass depending on the UPS output used. Model No. DK Description kva (incl. UPS fuse 16 A) kva (incl. UPS fuse 2 A) Sub-distribution mm (19 ) sub-distribution for PMC 12 Outlets 4 x C19 and 2 x 2 A CEE-conforming Single-phase, individually fused. Allows the direct connection of up to 6 pieces of equipment. A qualified electrician must carry out the installation. Model No. DK Pack PMC 12 Plug & Play Sub-distribution for PMC 12, 4.5 and 6 kva This sub-distribution facilitates simple installation and commissioning of the PMC 12 UPS, 4.5 and 6 kva. All that is needed is a single-phase 2 A connection to DIN/EN Model No. DK Pack Sub-distribution mm (19 ) sub-distribution for PMC 40 UPS Allows the directly fused connection of single and -phase equipment. In this way, up to 4 PSM busbars may be connected directly to the PMC 40 UPS via the relevant connection cables. Additionally, there are six single-phase outlets (16 A) available via C19 jacks. Model No. DK Pack Other UPS Options RCCM D Shutdown Software PMC 12 Relay Card Model No. DK Pack Model No. DK Licences Model No. DK Pack SNMP card, budget version SNMP card CS121 wth floating contacts Parallel hot swap chassis for 2 UPS systems Parallel hot swap chassis for for UPS systems Single licence Licence bundle (5 servers) Licence bundle (25 servers) AUS: rimatrix5.com.au NZ: rimatrix5.co.nz
25 PDR Racks Power Distribution Rack PDR Accommodate a maximum of 8 PDMs Height 1.20 m for 4 PDMs and 2m height for 8 PDMs PDM may be retrofitted whilst operational A maximum of 2 racks may be fitted to the sub-distributor Fully shock-hazard protected Main switch in various options1): Isolator switch On-load isolator Power circuit-breakers RC circuit-breaker Low-voltage distribution up to250 A1) Depending on the standards of the local power supply company Note: Observe the standards of the local power supply companies. Material: Sheet steel Surface finish: Enclosure frame: Dipcoat-primed Doors, roof and base/ plinth: Dipcoat-primed, powder-coated in RAL 705 Gland plates, punched sections with mounting flanges and mounting angles: Zinc-plated, passivated Supply includes: Enclosure frame with door (without tubular door frame), rear panel, side panels and roof plate, levelling feet including base/plinth adaptor, earthing of all enclosure panels, busbars shock-hazard protected, main switch integrated. Extended delivery times. Also required: Power Distribution Module PDM Detailed drawing, available on the Internet. PDR RACKS Model No. DK Width mm Height mm Depth mm Power Distribution Rack PDR Possible number of PDM Modules Pack Power Distribution Module PDM mm (19 ) Power Distribution Module mechanically locked in the rack Scalable Including master switch, optional RC circuitbreaker 4 fused -phase outlets to the rack x 20 V/16 A per outlet Connected load 400 V/ AC, max. 6 A Supply includes: mm (19 ) module, U Model No. DK Version PDM 482.6mm (19 ) 4 outlets per 10kW PDM 19, 4 outlets, project specific Connection cable with 2A CEEkon connector Plug & play connection cable to the server enclosures Model No. DK Length m Pack AUS: rittal.com.au NZ: rittal.co.nz 25
26 Cooling Product COOLING Perhaps the most pressing issue in today s data centre, management of heat and humidity, is paramount in maintaining a high performing data infrastructure. Higher processing speeds and the implementation of high density blade servers has led to enclosure heat densities of 0kW and higher. RimatriX5 cooling solutions incorporate the indusrty s most comprehensive and advanced technologies to meet the requirements of the hottest running data centres. Highly adaptable and easily scaled, data centres can leverage an array of solutions that includes simple air cooling, heat exchangers or sophisticated liquid cooling modules that provide direct liquid cooling to heat sinks on processors. Basic solutions CRAC systems LCP Extend LCP Inline LCP Standard/Smart LCP Plus/LCP T+ Low Density Your entry into professional IT climate control with aisle containment Mid Density The tailor-made solution for discerning data centres with aisle containmen t Cooling requirements High Density The most powerful solutions for high-end data centres. 26 AUS: rimatrix5.com.au NZ: rimatrix5.co.nz
27 Aisle Containment Three systems with a high level of efficiency Nowadays, servers are increasingly positioned in rooms that were not designed as data centres. As a result of hot air cushions below the ceiling, in particular, hot-spots in hot-spot racks are not dissipated. In order to consistently address this problem, Rittal has developed three systems for aisle containment. In the two variants of cold aisle (CRAC and Inline Cooling), we are able to provide a solution that is independent of whether there is a false floor available or not. Both provide cold air to the aisle, where it is then absorbed by the server inlets. In the third system, the hot air is extracted from the hot aisle, via the LCP Inline, without influencing the ambient temperatures, and then selectively re-emitted as cold air in the proximity of the equipment. The outcome is the same with all three systems: Increased reliability, greater cooling capacity and simultaneously improved energy efficiency. Rittal aisle containment (hot aisle) without raised floor Simple assembly using the existing components of Rittal aisle containment. Direct connection of the liquid cooling packages (LCP Inline) to an external cold water supply. Simple laying of pipework in the rack base/plinth. Suitable for use with high heat losses. Room-neutral dissipation of the heat loss. Simple management of air can make a significant difference to operating costs Containment systems are modular pods that simply ensure the cool air and warm air do not mix Containing the cold aisle helps manage air better and enables us to increase air or temperatures to the servers Containing the hot aisle helps to increase the return air temperature and make the cooling units run more efficiently Systems can be retrofitted to existing facilities or implemented as new Containment provides us with predictability and manageability This knowledge can be used to alter cooling parameters and reduce costs - Increase air on temperatures thanks to better control - Increase the water temperature to account for the fact that we now have a higher air on temperature - Slow down the fans to increase the delta T on the air side - Slow down the water flow rate and save on pump power at the central plant AUS: rittal.com.au NZ: rittal.co.nz 27
28 CRAC Systems - Data centres and server rooms CRAC SYSTEMS CRAC systems Fresh power for data centres and server rooms. Modern IT climate control technology ensures optimum thermal conditions in rooms exposed to high loads, such as data centres and server rooms. The main aim here is to ensure constant temperatures and precise humidity levels. Continuous-operation designs and redundant systems ensure that all key functions are maintained. Rittal CRAC systems dissipate waste heat from the IT equipment on demand, ensuring that the overall system operates in the most energy-saving way possible. The fan is positioned inside the raised floor. This provides for optimal air distribution in the raised floor and also reduces energy consumption by minimising pressure deflection losses. The integration of a heat exchanger with a larger surface area also enables potential savings in chilled water generation by utilising higher water inlet temperatures. Model No. SK Width Height Depth Useful cooling output 1 ) kw Operating voltage Volt/Hz Cooling medium Volumetric airflow at an external pressure loss of 20Pa m/h ) /500 water 2 ) /500 water 2 ) /500 water 2 ) /500 water 2 ) /500 Refrigerant R407c 2 ) /500 Refrigerant R407c 2 ) /500 Refrigerant R407c 2 ) /500 Refrigerant R407c 2 ) ) Output figures less heat from the fans. CW: 26 C/45% air inlet and 10 C/15 C water temperatures DX: 26 C/45% air inlet and 50 C condensation temperature 2) Other media available on request. Other options available on request. We reserve the right to make technical modifications. Benefits: The unit is available in a broad output range, and for a variety of cooling media. The unit supports optimum integration of both hardware and software. Optimum energy and space efficiency thanks to intelligent design features, such as the slanted heat exchanger and base integrated fan. Frame based on the popular TS 8 system. Functional principle: The CRAC system draws warm waste air from the top of your data centre, cools it with either water or refrigerant in a closed heat exchanger, and blows the cooled, filtered supply air into the unit s floor with overpressure. Equipment: User-friendly, high-quality control with an extensive range of functions and connectivity. Space-saving, readily accessible, high-efficiency fan. Flow and energy-optimised special heat exchanger with a generous safety factor. The standard scope of the system includes the enclosure and the supporting structure for integration into a raised floor, as well as an autonomous controller with graphic display and the integrated filters. Pre-defined component lists permit the project-specific integration of additional options such as a humidifier, an electric heater, diverse interfaces (BACnet, RS485...) etc. 28 AUS: rimatrix5.com.au NZ: rimatrix5.co.nz
29 LCP Systems The LCP Family Features: Rittal EC fans vary between 20% and 100% - enabling greater savings during idle periods The LCP can accept a wide range of water inlet temperatures - +6 deg C to +20 deg C which facilitates indirect free cooling for more days per year All units incorporate hot swap fans for ease of maintenance Possible to use with or without a raised floor Management and alarms via IP or BMS Remote monitoring, control and setup via web interface Additional sensors can be added e.g. Humidity LCP SYSTEMS LCP Smart - 20 kw Application and mode of operation: The LCP Smart draws in the air at the sides of the server enclosure rear, cools it using highperformance compact registers, and blasts the cooled air back into the front part of the server enclosure at the sides. Maximum efficiency is achieved, thanks to the use of EC fans. The heat exchanger of the LCP Smart supports the longest possible usage of free cooling. Benefits: High energy efficiency. Bayable with server/network enclosures based on TS 8 (H x D: 2000 x 1000 mm). Fans may be individually exchanged with the system operational, self-contacting. Basic CMC as standard. Touchscreen display may be retrofitted. Shorter servicing times. Extended functionality of the monitoring and control technology/software. Optimum adaptability thanks to dynamic, continuous control of the cold water volume flow. Control of the inlet air temperature and the temperature difference for the best possible supply to your server systems. Extremely robust thanks to its simple, optimised construction. Maximum power draw of 600W Model No. SK Width mm Height mm Depth mm Operating voltage Volt/Hz Usable U Useful cooling output kw Hz 20, 1~, 50/60 400, ~, 50/60 42 up to 20 AUS: rittal.com.au NZ: rittal.co.nz 29
30 LCP Systems LCP SYSTEMS LCP Plus - 0kW Application and mode of operation: Air/water heat exchanger, bayable with server racks based on TS 8 (H x D: 2000 x 1200 mm). Complete unit with 0 kw useful cooling output. Benefits: The separation of cooling andrack prevents water from penetrating the server rack. Increased assembly- and service-friendliness LCPs are easy to handle and may be transported in lifts and through doors. The low weight means a minimal load area. LCP Plus EC the energyefficient variant of LCP Plus, fitted with extremely electricity- saving EC fan technology. Approvals: see hardcover catalogue System Climate Control, page 29. Model No. SK Width mm Height mm Depth mm Description Operating voltage Volt/Hz Usable U Useful cooling output kw ) LCP Plus EC on request LCP Plus Hz 20, 1~, 50/60 400, ~, 50/60 20, 1~, 50/60 400, ~, 50/60 42 up to 0 51 up to 40 LCP Inline, useful cooling output up to 0 kw LCP Inline - 0 kw Application and mode of operation: The LCP Inline is designed for siting within a bayed enclosure suite. The hot air is extracted from the room or warm aisle at the rear of the unit, cooled, then blown out forwards into the cold aisle, where it is available to your IT equipment. The LCP Inline achieves maximum performance and efficiency in conjunction with Rittal cold aisle containment. With this product, a raised floor is not necessary. Equipment: High-performance heat exchanger with very even temperature distribution. Integrated condensate management. Controller with networking capability, compatible with all common communication standards (SNMP, BACnet etc.). Benefits: Combines the slimline design of the LCP with the function of room air-conditioning. Climate control technology, specially designed for IT environments with comprehensive monitoring functions. Frame based on the popular TS 8 system. Model No. SK Width mm Height mm Depth mm Operating voltage Volt/Hz Usable U Useful cooling output kw (42 ) Hz 20, 1~, 50/60 400, ~, 50/60 Hz 20, 1~, 50/60 400, ~, 50/60 42 up to 0 42 up to 0 0 AUS: rimatrix5.com.au NZ: rimatrix5.co.nz
31 LCP Systems LCPT+EC-25 kw Application and mode of operation: Air/water heat exchanger, bayable with server racks based on TS 8 (H x D: 2200 x 1200 mm). Benefits: Efficient cooling of server racks with high thermal loads. Fully redundant Two active cooling circuits and two switchable power circuits ensure the best possible resilience. The built-in controllers are capable of adapting all device parameters automatically to preserve the required climate conditions. A separate decentralised intelligence which automatically recognises emergency situations and responds appropriately with the autoload balancing and autorecovery functions. Interfaces which facilitate user-friendly operation and monitoring via the network or BSM systems. Optional: Three-way control valve Full BSM integration Air filter system Special colour Model No. SK Width mm Height mm Depth mm Description Operating voltage Volt/Hz Usable U Useful cooling output kw LCP T+ EC Hz 20, 1~, 50/60 47 up to 25 Cooling Accessories - Fan kits Fan Kits Excessive heat build-up is easily treated with Rittal s fan trays. By dispersing warm air out of the racks, fan trays ensure your equipment remains cool. Fan trays are fitted during configuration or retro-fitted without any disruption to the equipment within the rack. Part No. DNFAN2 DNFAN4 DNFAN4R Description 2 Fan Roof Mounted Fan tray 4 Fan Roof Mounted Fan tray 4 Fan Rack Mounted Fan tray AUS: rittal.com.au NZ: rittal.co.nz 1
32 RTT I/O unit PLC X2 LAN COM RS-485 RS-22 G + - Security - monitoring system CMC-TC processing unit II plus The monitor CMC-TC is the complete Security management concept for preventive protection, to guard against follow-on costs. At the same time, it is also the central organisational unit for connecting to facility management. SECURITY Processing Unit II (PU II) forms the basis of any application and provides a direct interface to the user network. The sensor units are linked to the PU II with various sensors. The function of the CMC-TC monitoring system is determined by the selection of sensor units and sensors. Electronic systems with monitoring of temperatures, fans and DC voltages, see page 502. Active Power System Module PSM, Power Control Unit PCU The sockets may be activated directly by the Processing Unit II, combined with an ammeter (max. 4 x 4 x 8 sockets). RTT I/O unit Up to 10 climate control devices with Comfort controller may be connected via one unit in master/slave mode. LAN (SNMP/WEB) GSM (SMS) ISDN (SMS) ISDN/analog modem point to point (SNMP/WEB) Liquid Cooling Package LCP The professional LCP water cooling system for data centres may be linked directly to the Processing Unit II. Processing Unit II (PU II): The nerve centre of the monitoring system CMC-TC The PU II serves as a coordinator between the sensor unit and the network. It is configured via the integral web server. I/O unit wireless Up to 16 sensors may be wirelessly incorporated into the CMC-TC system via this unit Access unit The doors of buildings, rooms and enclosures may be monitored, activated and opened via the network. Climate unit, Fan Control System FCS Fans are controlled via temperature sensors. Airflow monitors report any contamination of the filter mat, for example. The fan speed is controlled and monitored via the FCS. Universal I/O unit This measurement and alarm module indicates motion, vibrations, doors being opened, temperatures exceeded, and much more besides. The sensors may be selected for the application. 2 AUS: rimatrix5.com.au NZ: rimatrix5.co.nz
33 Security - CMC plus monitoring units SECURITY Model No. DK Sensors/Actuators Max Temperature sensor Humidity sensor Analog sensor input module 4 20 ma Access sensor1) 4 x Vandalism sensor Acoustic sensor Airflow monitor Smoke alarm Motion sensor Digital input module Digital relay Voltage monitor Voltage monitor with 10 A switch output Voltage monitor with 16 A switch output V voltage monitor Leak sensor Leak sensor, 15 m Connection cable 1) Up to a maximum of 5 sensors may be connected in series. Model No.DK Latch/reader Max Ergoform-S handle FR/PS/TC/TE 2 on request Electromagnetic Ergoform-S QR Comfort handle TS TS 8 transponder handle with Legic unit Universal lock unit Digital relay output module for room door Universal handle Smartcard reader for door release Magnetic card reader for door release Coded lock for door release Connection cable 1) Up to a maximum of 5 sensors may be connected in series. AUS: rittal.com.au NZ: rittal.co.nz
34 FIRE ALARM & EXTINGISHER Fire Alarm and Extinguisher System DET-AC XL For room and rack applications Fire Alarm and Extinguisher System DET-AC XL No fire without oxygen. Three ingredients are necessary to keep a fire burning: Fuel, heat and oxygen. As soon as just one of these factors is removed, the fire will be extinguished. As the high availability demands of IT systems rule out the use of water for firefighting, the protected space is flooded with an extinguisher gas to smother fires quickly and without leaving residues. Thanks to its width of just 00 mm, the Rittal fire alarm and extinguisher system DET-AC XL is ideal for spacesaving integration into a rack suite or IT room. Three solutions are available in the standard version: Extinguishing for: up to 8 racks up to 16 racks up to 24 racks In addition, we are able to configure both room and rack extinguisher systems to your individual specifications. Function principle: The detection system of the DET-AC XL draws room or rack air in continuously and detects even the tiniest smoke particles during the initial phase of a fire, the so-called pyrolysis phase. After a defined delay time, the extinguisher gas bottle is opened electrically and the gas flows out into the room or racks via the extinguisher nozzles. Benefits: Extinguisher system forroom volumes up to 84 m Rack extinguisher system for up to 24 racks Suitable for incorporation into TS 8 server rack suites Integration into the RimatriX concept Simple project planning on the basis of standard packages Innovative extinguisher gas NOVEC 120 Ecological compatibility Uncritical for IT components 4 AUS: rimatrix5.com.au NZ: rimatrix5.co.nz
35 RiZone Management For Microsoft system centre operations manager server rooms What can the RiZone Data Centre Management Software do? 1. RiZone is the management platform for all components in the data centre infrastructure. Monitoring of redundant data centres (up to Tier IV). Fast configuration, automatic detection of all active RimatriX5 components. Precise adaptation to requirements, a modular licence model. Efficient administration of the physical infrastructure (from the single-enclosure data centre through to the maxi-data centre ), with a high level of flexibility and availability. 2. RiZone can communicate with a server management system (e.g. System Center Operations Manager from Microsoft) and exert direct influence over the availability of individual applications.. RiZone supports the protocols SNMP and BACnet for connecting and monitoring all equipment in the IT and building infrastructure. At last, isolated thinking in IT and building management is a thing of the past. RiZONE MANAGEMENT RiZone Easy to use, comprehensive and profitable All active RimatriX5 components are automatically detected and administered in the user interface. Any components that support the protocol SNMP or BACnet may be incorporated via the configuration manager. This means that all RiZone functions are then available to these components. A workflow editor represents all mathematical operations and configures components across the board, facilitating optimum interconnection between all parameters. This opens up brand new opportunities to optimise the entire infrastructure. The architecture is easily adapted to customer requirements. All potential applications from the small server room to the large data centre may be represented. Configured as a high-mtbf a pplication, the individual RiZone servers monitor one another to ensure availability. If one server fails, the second server assumes full functioning and alerts the administrator. If the RiZone server is disconnected from the network, the RimatriX5 components are capable of maintaining data centre operation. Individual messages or results from the sensors and the workflow may be transmitted, e.g. to a server management system. This opens up the opportunity of responding directly at server level if malfunctions occur in the data centre, which in turn significantly enhances the availability of each application. AUS: rittal.com.au NZ: rittal.co.nz 5
36 Security Rooms - Basic protection solution for data centres SECURITY ROOMS The new Efficiency Room IT environments today must be flexible, efficient and secure. Only modular room systems can meet all these requirements and also offer fast, clean conversions and extensions. Efficiency Rooms (LER) offer uncompromising flexibility and extremely short delivery times. System checks are state of the art. Why should you, as the customer, be content with less security, flexibility and long-term benefits? Only the system testing of a room structure. Benefits: Efficient value for money Optimum use of your investment, due to a growing and modular structure of the entire data centre Absolute investment protection, thanks to the option of complete dismantling and reassembly of the security room Efficient design Optimum space utilisation of the structural conditions Fast assembly times Ideal for technology and infrastructure rooms Eco-friendly manufacturing technique Efficient project handling Extremely short delivery times (10 working days for basic package) Customised data centre solution, thanks to the flexible modular principle Flexible self-assembly with a supervisor Efficient climate control concepts Optimum air routing, e.g. hot/cold aisle containment Efficient climate control technology System-tested basic protection Compliance with the latest EN and DIN standards Multi-functional risk coverage (fire, water, break-ins...) One modular system infinite possibilities The new Efficiency Rooms are based on the modular principle. The basic package already includes a solid range of basic features, and can be adapted to individual customer requirements with various optional modules. Basic package Modular room construction, security functions, door system, cable duct, delivery and assembly supervisor Application example: Infrastructure room The Efficiency Rooms LER Basic and LER Extend are ideally suited as a technical room for the infrastructure components of a data centre. Here, the climate control and power technology are equipped with a basic level of security. Access monitoring Full assembly Cable duct system Lighting systems Climate control technology Monitoring Power Fire detection/ Base system engineering fire extinguishing Project management Optical package Data and network technology Optional packages Security, efficiency and availability are at the heart of customer requirements. The LER option packages include solutions for security, systems engineering, climate control, power distribution and monitoring. With these versatile options, IT managers can customise their own precisely tailored, secure, made-to-measure IT package. Fire Water used for fire-fighting Corrosive gases Vandalism Unauthorised access Electro-magnetic Interference Dust Falling debris Theft/ break-ins 6 AUS: rimatrix5.com.au NZ: rimatrix5.co.nz
37 System test SECURITY ROOMS Forget simple component tests - only system tested room constructions make your data centre secure! 1 Criterion Standard Conventional construction 2 System test Test as a complete system or construction according to the following standards X Fire protection Test at temperatures of up to over 1000 C ECB S certification according to EN , 50K temperature rise and 85% rel. humidity over 24 hours (soak-out period), heating time 60 minutes 50K temperature rise and 85% rel. humidity over 0 minutes, X LSR 18.6 E LER Basic X without soak-out period X X F120 as system test according to EN 16 (DIN 4102), X for the design of the room units and their installation modules. F90 as system test according to EN 16 (DIN 4102), for the design of the room units and their installation modules. X F180 as component test only according to EN 16 (DIN 4102), wall system only X F120 as component test only according to EN 16 (DIN 4102), wall system only ( ) F90 as component test only according to EN 16 (DIN 4102), wall system only Explosion Detonation test as system test of 200 kg TNT from 40 m distance X Water Standing water, 72 hours, 40 cm, 20 droplets maximum X Dust tightness Fire-fighting water, IP x6 as system test according to EN , for the design of the room units and their installation modules. X relative humidity, 85 %, over 24 hours (soak-out period), X 60 minute heating time, in accordance with EN relative humidity, 85 %, over 0 minutes X X IP 5x as system test according to EN , for the design of the room units and their installation modules X Corrosive fire gases Fume/smoke (corrosive gas) tightness based on EN 164- (DIN 18095) X X Unauthorised access WK as system test in accordance with EN 1627 / 160, for the design of the room units and their installation modules, e.g. doors X WK 2 as system test in accordance with EN 1627 / 160, for the design of the room units and their installation modules, e.g. doors X WK 4 as component test only in accordance with EN 1627 / 160, door system only X Debris loads Impact test as system test, lateral impacts of 200 kg from 1.5 m height X EMC protection Verified in accordance with tests on comparable components by Aachen Technical University X X X X X X X X LER Extend X X X X X X + X X 1 System-tested products are tested as a complete design or construction. This includes both the room units and their installation modules such as doors, cable ducting or ventilation slides. Component tests on the other hand relate to individual parts only. 2 The conventional construction method denotes room constructions made of RIGIPS (gypsum), concrete and other commonly used building materials, which are unable to provide sufficient security for data centre applications. In general, conventional construction methods are tested for use as a fire retardant wall. AUS: rittal.com.au NZ: rittal.co.nz 7
38 DATA CENTRE CONTAINER Data Centre Container DCC - Energy efficient, mobile, plug-and-play Data Centre Container The Rittal Data Centre Container DCC has been developed specifically for outdoor IT system operations. The perfect temporary data centre to bridge the duration of alterations, expansion measures or relocation, but no less ideally suitable as a permanent IT or server room. The absolute highlight is the innovative direct free cooling, which brings savings of up to 40% on the usual costs for cooling. At the same time, the container guarantees seamless integration of a UPS, fire alarm/extinguisher system, power distribution, raised floor, access control and monitoring functions. Benefits: Drastically reduced energy costs PUE (Power Usage Effectiveness) below 1.2 Innovative direct free cooling Highly efficient UPS Plenty of space and top quality Up to 29 U (7 racks) and max. 6 kw/rack Extra-wide ( m) and extremely robust outdoor container Deliver connect up (data and power) ready to use Monitor and manage the data centre and infrastructure (RiZone) All-in-one concept, no additional external installations Simple planning fixed price for data centre Long autonomy time in case of power failure: Min. 15 minutes Technical data: Container: Particularly generous dimensions: Outside (L x W x H) 6055 x 000 x 250 mm Inside (L x W x H) 5722 x 2664 x 2896 mm Usable floor space: 15.2 m 2 Fire protection to EN 16/DIN 4102: F0, optionally F90, type-tested Burglar resistance to EN 1627/160 Resistance class WK2, optionally WK Bulkhead system: Type: Hard bulkhead DN200 Dimensions of packing space: 120 x 120 mm Climate control direct free cooling: Available with 7 and 10 kw units. Up to units can be integrated. Technical data of 7 kw unit: Type: RDF Rittal direct free cooling Useful cooling capacity (ta 2 C, RH 40%): 7.0 kw Max. outdoor temperature: +40 C/ Min. outdoor temperature: 5 C Refrigerant: R407c Filter grade: F 7 Unit dimensions (H x W x D): 270 x 780 x 25 mm Sound pressure level, A-weighted, 5 m from external unit, free field: 40 db (A) Raised floor: Substructure type: Control room Number of slotted plates dependent on number of racks Total raised height: 00 mm Optional: 19 rack system, UPS, fire alarm/extinguisher system, power distribution, sun protection. Power distribution: Infeed: Wall-mounted CEE connector, 125 A, -phase/n/pe, 400 V/50 Hz Enclosure dimensions (W x H x D): 600 x 2000 x 400 mm 8 AUS: rimatrix5.com.au NZ: rimatrix5.co.nz
39 Modular Safes - Strong arguments for maximum security Modular Safes Protection for distributed IT infrastructure is no longer a problem thanks to the Rittal mini data centres. The safes protect their valuable contents against a diversity of physical threats, such as fire, water, smoke gases, dust and unauthorised access. The Rittal product range offers the ideal solution for every level of business security demand. Small and medium-size companies benefit from the modular scalability of the concept. The modular safe system is as simple as it is ingenious with maximum flexibility and performance. MODULAR SAFES The scalability, too, is exemplary, with unlimited options for suite creation. The modular safes are not only easy to assemble, they are equally easy to re-assemble, for example should relocation become necessary. It goes without saying that Rittal configures the security safes to individual customer specifications with state-of-the-art, energy-efficient components. There are thus practically no restrictions to be placed on your plans for climate control solutions, system controllers or early fire detection, fire alarm and extinguisher systems. Benefits you can rely on: Energy-efficient climate control with water- or refrigerant-based cooling tailored to actual demand. Modular, scalable protection against potential physical threats such as fire, water, smoke gases and unauthorised access. Integrated security concept combining a monitoring system and a fire alarm and extinguisher system. Autonomous power supply with a modular busbar system and 19 compatible UPS. High, multifunctional IT protection ensures improved ratings with insurance companies. Limitation of liability risks for the responsible operator. Long-term investment value: No barriers to relocation at any time. Expandability for graduated investment in line with IT growth. AUS: rittal.com.au NZ: rittal.co.nz 9
40 Modular Safes MODULAR SAFES Basic Safe Compact Rittal presents the smallest climate-controlled data centre. Small companies, in particular, can now be offered a cost-efficient solution for the protection of tape libraries, individual 19 servers or the like. Benefits: Description of standard features Security enclosure with operating and service doors (three-point locking) Cable entry in both side elements Cooling capacity 1./2.4 kw Usable height for installations 15 U Compatible options Early fire detection system EFD Plus Fire alarm and extinguisher system DET-AC Plus Monitoring CMC-TC Uninterruptible power supply PMC server rack Applications Micro data centre for small companies Protection for servers, storage applications Suitable for integration into smaller office rooms Storage of personal data, e.g. doctors surgeries or tax advisors Modular Safe - Extend The Modular Safe - Extend offers ultimate security and efficient protection against potential physical threats. Available in a variety of sizes, it permits free configuration in respect of the doors and locking systems, cable bulkheads and climate control solutions. Protection standards Fire protection F90 Compliance with limit values 50 K ΔT and 85% relative humidity for 0 minutes Burglar resistance class WK4 Protection against smoke gases Protection against dust and water jets All tests were performed as system tests and confirmed by way of test reports. Colour: Modular Safe: RAL 705 Modular Safe - Light The Modular Safe - Light promises a dependable basic level of protection, particularly for locations which place lesser demands on physical security. It is available in both 47 U and U versions, each with a wide range of configuration options. Thanks to its reduced weight, the Modular Safe Light is also suitable for locations with a limited floor load-bearing capacity. Protection standards Fire protection F0 Burglar resistance class WK2 Protection against smoke gases Protection against dust and water jets The tests were performed as system tests and confirmed by way of test reports. Colour: Modular Safe: RAL AUS: rimatrix5.com.au NZ: rimatrix5.co.nz
41 NOTES AUS: rittal.com.au NZ: rittal.co.nz 41
42 NOTES 42 AUS: rimatrix5.com.au NZ: rimatrix5.co.nz
43 R Literature List Catalogue A comprehensive guide to all Rittal products IT Catalogue Annual catalogue covering Rittal's full IT product portfolio Rittal RimatriX5 RimatriX5 Data Centre catalogue covering racks, cooling, power, security, and remote management IT infrastructure solutions for maximum availability Efficient, flexible, secure. issue TWO Rittal4Racks IT Rack solutions IT rack solutions on demand AUS: rittal.com.au NZ: rittal.co.nz 4
44 Head Office - Australia Parraweena Road Miranda NSW 2228 T E [email protected] W rittal.com.au Å New Zealand 21 Bell Road South Lower Hutt Wellington F E [email protected] W rittal.co.nz Å SYDNEY MELBOURNE BRISBANE ADELAIDE PERTH AUCKLAND WELLINGTON Distributed by: SECURITY REMOTE MANAGEMENT
IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre
IT infrastructure Efficiency-boosting solutions nextlevel for data centre 2 Rittal IT infrastructure The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind,
Data Centre Solutions
Issue 6 Data Centre Solutions RACKS POWER COOLING MONITORING SECURITY SERVICE & SUPPORT The simple route to the perfect data centre Data centres are complex systems. Software, hardware and IT infrastructure
Data Centre Solutions
Issue 4.1 Data Centre Solutions RACKS POWER COOLING MONITORING SECURITY SERVICE & SUPPORT The simple route to the perfect data centre Data centres are complex systems. Software, hardware and IT infrastructure
Data Centre Solutions
Issue 5 Data Centre Solutions RACKS POWER COOLING MONITORING SECURITY SERVICE & SUPPORT The simple route to the perfect data centre Data centres are complex systems. Software, hardware and IT infrastructure
Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS
Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS STANDARD & ECONOMICAL BasicRack A complete low-cost, high-quality basic equipment management system. Design Six web channel holes per side allow
Cabinets 101: Configuring A Network Or Server Cabinet
Cabinets 101: Configuring A Network Or Server Cabinet North, South and Central America White Paper May 2012 www.commscope.com Contents Background Information 3 What is a network or server cabinet? 3 What
Rack Systems Solutions
Rack Systems Solutions Designed to simplify cable management and improve power distribution Engineered by APC by Schneider Electric for Dell, NetShelter S is the next-generation rack enclosure solution
Powerware Enclosure Solutions Product Focus
Powerware Enclosure Solutions Product Focus Powerware Enclosures IT availability and reliability are critical corporate issues in today s demanding, mission-critical environments. For this reason, it is
RiMatrix S Make easy.
RiMatrix S Make easy. 2 RiMatrix S Rittal The System. The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure, power
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels
The UPS for the highest security in industry and data centres
The UPS for the highest security in industry and data centres P R E M I U M 6,000-20,000VA T E C H N O L O G Y www.online-usv.de Perfect: The ultimate protection against blackout and data loss The new
Make IT easy: The new TS IT rack
Make IT easy: The new TS IT rack The new TS IT rack. A new global standard for network and server equipment. At CeBIT 202, Rittal unveiled a newly developed rack system which is set to redefine the global
30-120 3 Phase Modular Finally the benefits of Modular ups are for all
MUST 30-120 3 Phase Modular UPS Finally the benefits of Modular ups are for all MUST 30-120 MUST means Modular UPS System Three-phase MUST 30-120 is an uninterruptible power supply with double conversion
Rittal the time has come...
Rittal the time has come...... for the Data Centre of the future Sustainable energy efficiency! Energy Outstanding climate protection and energy efficiency with Green IT. Modular, scalable IT infrastructures
Technical Data. back-up time in minutes 100% load 6 7 0 5 6 0 5 0 50% load 15 18 0 15 16 0 15 0
The protectoq is a On-Line double conversion UPS-system according to IEC / EN 62040-3 (VFI-SS-111) with sinus wave output voltage in each operation mode, LCDindication, RS232 interface, USB-connection,
Cabinet V800 V800 CABINETS
V800 Cabinet Siemon s V800 cabinets provide a robust, cost-effective enclosure solution that provides valuable Zero-U space on each side of the equipment rails for cable management, PDU mounting or connectivity
Power distribution in data centres
Power distribution in data centres by Manuel Lotz / Matthias Ribbe White Paper 09 Copyright 2008 All rights reserved. Rittal GmbH & Co. KG Auf dem Stützelberg D-35745 Herborn Phone +49 (0)2772 505-0 Fax
Technical data UNIBLOCK UBSF 180 625
Data TECHNICL DT Technical data UNIBLOCK UBSF 80 6 Output data Type UBSF 80 UBSF 0 UBSF 00 UBSF 6 Output power 80 kv 0 kv 00 kv 6 kv Output voltage 80/77 V 0/ V 0/ V 0/ V Output current 7 8 66 80 Power
DIGITUS Network & Server Cabinets. UNIQUE Series
DIGITUS Network & Server Cabinets UNIQUE Series Benefits - Server Rack 4-Point locking system front door 3-point locking system rear door Swing handle lock with profile zylinder in front and rear door
How To Build A T7 Rack For Information Technology
THE NEXT GENERATION RACK FOR INFORMATION TECHNOLOGY THE RACK CABINET FOR INFORMATION TECHNOLOGY T7, THE HI-TECH HEART OF THE BLADESHELTER SYSTEM The real answer to the requirements of: Safety Versatility
SERVER ROOM CABINET INSTALLATION CONCEPTS
SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS ZPAS 169 EXAMPLES OF SERVER ROOMS PROJECTS WITH ZPAS CABINETS Data Box in the
Rittal Data Center Enclosures Modular and wallmount enclosures, racks and accessories
Rittal Data Center Enclosures Modular and wallmount enclosures, racks and accessories Rittal TS8 Modular and Wallmount Enclosures and Racks Your Data Center Partner Rittal TS8 Modular Enclosures Rittal
Eaton 93PM UPS Where aesthetics meet intelligence.
Brochure 100 kw Eaton 93PM UPS Where aesthetics meet intelligence. 93PM features and benefits The Eaton 93PM UPS combines unprecedented and reliability with eye-catching design. A space-saving, flexible
Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE
Local Area Networks (LAN) Servers Data centers Internet centers (ISP/ASP/POP) Industrial PLCs EPOS (Electronic Point of Sale) Systems Emergency devices (lights/alarms) Electro-medical devices Telecommunication
Thyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers
Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers An intelligent physical infrastructure is required
Table of Contents. RimatriX5 IT Solutions from Rittal. Product Overview Section 1... Pages 3-11. Enclosures Section 2...
Rittal IT Solutions Table of Contents RimatriX5 IT Solutions from Rittal Product Overview Section 1... Pages 3-11 Enclosures Section 2... Pages 12-51 Cooling Section 3... Pages 52-73 Monitoring and Security
LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification
08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and
RIELLO ELETTRONICA. Master HP
RIELLO ELETTRONICA Master HP LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTRES TELECOM- MUNICATIONS DEVICES E-BUSINESS (Servers Farms, ISP/ASP/POP) INDUSTRIAL PROCESSES INDUSTRIAL PLCS ELECTRO- MEDICAL DEVICES
Edition Perfect combination 9 Power supplies Electronic P Edition kaging www clear order..biz information in the catalogue
9 Power supplies Übersicht PROLINE Overview... 0 Power supplies Cabinets... 1 Wall mounted cases... 2 slimpower AC/DC switched-mode power supply 42 W, 3 HP Compact and low interference Accessories for
CRAC Precision climate control units for data centres
CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have
InstaPATCH ZERO Solution Guide
SYSTIMAX Solutions InstaPATCH ZERO Solution Guide Rapid Server Deployment and Change Management North, South and Central Americas 1 As data centers face ever-increasing IT demands, growth demands and evolving
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications
SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications Model #: SU3000RTXL3U 3000VA online 3U rack / tower UPS Enhanced serial communications
LIBRA USV-Anlagen von EBT (10-800KVA) LIBRA pro. UPS 10-100 kva three-phase / single-phase 10-800 kva three-phase / three-phase.
LIBRA USV-Anlagen von EBT (10-800KVA) LIBRA pro online UPS 10-100 kva three-phase / single-phase 10-800 kva three-phase / three-phase LOCAL AREA NETWORKS (LAN) INTERNET CENTERS (ISP/ASP/POP) ELECTRO-MEDICAL
Material test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.
19" Data Racks Attractive design and high quality are characteristic. Basic framework is welded from multiple bent metal plate, which assures great rigidity suitable for heavier equipment. All profile
PowerGem Pro Uninterruptible Power Supply
Uninterruptible Power Supply User-friendly Intelligent Ultra reliable Range The Most Intelligent On-Line Double Conversion Power Protection System The range achieves higher reliability and greater immunity
DATA CENTRES POWERED BY EXCEL
DATA CENTRES POWERED BY EXCEL MAXIMISE EFFICIENCY BOOST PERFORMANCE INCREASE R.O.I. WITHOUT COMPROMISE Excel is a world-class premium performance end-to-end infrastructure solution. Designed, manufactured,
Eaton 93PM UPS Efficient. Scalable. Innovative.
Product rochure 20-100 kw aton UPS fficient. Scalable. Innovative. features and benefits The aton UPS combines unprecedented and reliability with an eye-catching design. space-saving, scalable and flexible
How To Use Rittal'S Rizone
RiZone Data Centre Infrastructure Management Enclosures Power Distribution Climate Control IT INFRASTRUcTURe SOFTWARE & SERVICEs RiZone Data Centre Infrastructure Management What can the RiZone Data Centre
Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009
Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
Low Voltage Switchboards The Best Technical Solution for Your Ship
The Best Technical Solution for Your Ship Wärtsilä SAM Electronics Optimal Power Distribution The uninterrupted supply of power to systems and consumers onboard modern ships is an extremly important matter.
How To Power A Bladecenter H Servers
Solutions Guide for IBM Data Center Architecture: IBM BladeCenter H Servers In today s high-demand enterprise environment, organizations need a reliable infrastructure to run compute-intensive applications
Secure your IT equipment with confidence... secure with NetClosure
Secure your IT equipment with confidence... secure with NetClosure SERVER CABINETS NetClosure s REM Series Server Cabinet is the ultimate solution designed and engineered for demanding data center environments.
DELTA3-1. Delta 3 Data Centre Rack Solution
DELTA3-1 Delta 3 Data Centre Rack Solution Contents Building on more than 50 years of British design and innovation, Cooper B-Line introduces Delta 3 ( Delta cubed ). Designed to offer M.O.R.E. to customers
DATA CENTER SOLUTIONS
DATA CENTER SOLUTIONS Nobody Makes Better Data Center Equipment Maximize availability, manageability and efficiency with cost-effective solutions from a dependable partner. Provide reliable, efficient
Model #: SMART2200CRMXL
Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: +(773) 869 1234 E-mail: [email protected] Model #: SMART2200CRMXL SmartPro Compact Rackmount UPS System - Precision Protection for
Linkeo 19" freestanding cabinets
87045 LIMOGES Cedex France Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 Linkeo 19" freestanding cabinets Page 1. General characteristics....1 2. Range....2 3. Technical characteristics...3
SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial
SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SU5000RT4UHV Description Tripp Lite SU5000RT4UHV 5000VA / 5kVA /
Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC
TM 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM D400E Data Module (60Hz) The EDGE D400E is designed to meet high power density requirements for both the HPC and Web Scale environments while
ADC-APC Integrated Cisco Data Center Solutions
Advanced Infrastructure Solution for Cisco Data Center 3.0 Ordering Guide ADC-APC Integrated Cisco Data Center Solutions The evolution of data centers is happening before our eyes. This is due to the
Knürr Miracel. Knürr Miracel. 19 Network and Server Rack Platform 1.12 to 1.22 1.11
Knürr Miracel 19 Network and Server Rack Platform 1.12 to 1.22 1.11 19" Server Rack: Knürr Miracel Strong points 1.13 Knürr Miracel ASP ASP/Server Rack 1.16 Knürr Miracel Server Rack 1.18 Knürr Miracel
SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial
SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial MODEL NUMBER: SMART2200RM2U Highlights 2.2kVA / 2200VA / 1920W line interactive 2U
Knürr Smaract. Knürr Smaract. CompactRack
CompactRack Features Ample space for components and cabling provided in an efficient, compact design. The innovative frame concept with triangular extrusions ensures low weight while maintaining high stability.
APC APPLICATION NOTE #112
#112 Best Practices for Deploying the InfraStruXure InRow SC By David Roden Abstract The InfraStruXure InRow SC (ACSC100 and ACSC101) is a self-contained air conditioner for server rooms and wiring closets.
Customized Server Cabinets
GOING GREEN WITH CUSTOMIZABLE CABINETS AND RACKS Designed to provide industry leading airflow, CyrusOne s cabinets and rack solutions promote optimal cooling and contribute to reduced power consumption.
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
Rittal The System. Faster. Better. Worldwide CLIMATE
IT infrastructures Rittal The System. Faster better worldwide: Everything we do centres around the benefits to you. For you, we have developed a perfectly coordinated system platform that unites innovative
AIS 3000 APC AIS 3000 15kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass
AIS 3000 APC AIS 3000 15kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass APC AIS 3000, 12 kw / 15 kva,input 208V 3PH / Output 120V, 208V, 208V 3PH, Interface Port DB-9 RS-232,
DCF Optimized Rack System Selection Guide
DCF Optimized Rack System Selection Guide DCF Optimized Rack System: Optimized Design, Optimized Delivery, Optimized Value A Rack System Designed to Meet The Challenges Your Data Center Faces Today Your
BLADE S-MAX Cabinet for Blade Server
Cabinet for Blade Server 1 2 Overview Material specification Corner verticals: 1.5 mm steel End frames: 1.5 mm steel Panel mounts: 2.0 mm steel Panel mount supports: 1.5 mm steel Side panels, door and
Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments
Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Model #: SM2000RMX Heavy-duty, industrial-grade metal housings Shock and vibration rated to MIL-STD-810D 19 inch
SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial
SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SMART500RT1U Description Tripp Lite's SMART500RT1U intelligent, line-interactive rack/tower uninterruptible
Rack Power Distribution
The Rack PDU Selector is located at: www.apc.com/tools/selector/pdu Test drive a metered or switched Rack Power Distribution Rack PDU at testdrive.apc.com 132 Fairgrounds Road West Kingston, RI 02892 Phone:
APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out
APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS, 3750 Watts / 5000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model Includes: CD with software,
19 DYNAmax Free Standing Server C A B I N E T s
9 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server Cabinets FAMILY W=600mm and W=800mm DYNAmax Series Free Standing Server Cabinets DYNAmax series Servering Enclosures, provide
InForm Mobile Units. Selection. Equipment trolley, filing trolley Printer/PC trolley Overhead/demo trolley
Selection Equipment trolley, filing trolley Printer/PC trolley Overhead/demo trolley Basic mobile unit Basic mobile with vertical profiles Installation options Functional shelf, low Functional shelf, inclinable
Data Sheet Fujitsu PRIMERGY CX1000 S1 with 38 cloud server nodes
Data Sheet Fujitsu PRIMERGY CX1000 S1 with 38 cloud server nodes The Cool-Central architecture for Scale-Out Cloud Data Centers: Scale Big- Spend Small PRIMERGY CX1000 is a new product category within
MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4
CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,
Open Rack Hardware v1.0
Open Rack Hardware v1.0 Authors: Pierluigi Sarti, System Designer Steve Mills, Mechanical Engineer 1 Scope This document describes the technical specifications for the custom rack that houses Open Compute
19 DYNAmax Free Standing Server C A B I N E T s
9 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server Cabinets FAMILY W=mm and W=800mm DYNAmax Series Free Standing Server Cabinets DYNAmax series Servering Enclosures, provide
PRODUCT PRESENTATION PROTECT B.PRO YEAR 2013 NOVEMBER 2012 DATA & IT, SBU C-UPS, PM/SR
PRODUCT PRESENTATION PROTECT B.PRO YEAR 2013 NOVEMBER 2012 DATA & IT, SBU C-UPS, PM/SR CLASSIFICATION CLASSIFICATION ACC. TO - AEG S UPS PRODUCT PORTFOLIO - IT S APPLICATION ORIENTED USE - UPS PRODUCT
Cisco Redundant Power System 2300
Cisco Redundant Power System 2300 The Cisco Redundant Power System 2300 (RPS 2300) increases availability for converged data, voice, and video networks. The system delivers power supply redundancy and
Smart-UPS On-Line 230 V
Smart-UPS On-Line 230 V Unity output power factor single-phase, double-conversion online UPS with advanced management features A versatile UPS developed for unstable power conditions worldwide Smart-UPS
COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C
COOLS conditioned server - racks for direct installation into the room COOLSIDE box INVERTER R410A E C 2 COOLSIDE box GENERAL FEATURES COOLSIDE BOX is a split system consisting of an outdoor motocondensing
SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire
SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire MODEL NUMBER: SU6000RT3UHV Highlights 6000VA / 6kVA / 4200W on-line double-conversion
T1 Backhaul Connectivity Solution All Products :: Application Note
Telect 1 RU Customer Interface Panel (CIP) Enables Demarcation, Remote Circuit Maintenance and Trouble Isolation at the Backhaul Node The Application: T1 Demarcation and Testing in Backhaul Environments
Rack Power Distribution. Worldwide
Rack Distribution Worldwide Introduction APC TM by Schneider Electric TM offers a wide array of standardized Rack Distribution Units (PDUs) designed to increase manageability and efficiency in your data
Power Distribution Considerations for Data Center Racks
Power Distribution Considerations for Data Center Racks Power Distribution Considerations for Data Center Racks Table of Contents 3 Overview 4 At what voltage do you run all the IT equipment? 4 What electrical
2 Rittal Micro Data Centre
Micro Data Centre 2 Rittal Micro Data Centre The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure, power distribution,
CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
4.0 UPS dedicated to ICT for unmatched energy savings
4.0 UPS dedicated to ICT for unmatched energy savings Introducing UPSaver by Borri, a new modular UPS series for the ICT industry, totally configurable, quickly scalable, with high efficiency and low TCO.
Cisco Nexus 7000 Series Power Supply Modules
Cisco Nexus 7000 Series Power Supply Modules Product Overview The Cisco Nexus 7000 Series Power Supply Modules (Figures 1 and 2) deliver fault tolerance, high efficiency, load sharing, and hot-swappable
How To Upgrade An Hp Power Distribution Rack To A Power Distribution Unit
Overview Power protection in the data center is critical to maintain up time, and the increased densities in data centers is driving the need for uninterruptible power with increased power density, power
SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial
SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial MODEL NUMBER: SMARTINT3000VS Highlights 3kVA / 3000VA / 2250W line interactive tower UPS system 230V
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
Datasheet Fujitsu PRIMERGY CX1000 S1 with 38 CX120 S1 The Cool-Central Architecture
Datasheet Fujitsu PRIMERGY CX1000 S1 with 38 CX120 S1 The Cool-Central Architecture New Cloud server infrastructure platform for Scale-Out data centers Scale Big - spend small PRIMERGY CX1000 is a new
Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server
Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server Blade Made Easy Fujitsu PRIMERGY BX Blade Servers provide a faster, simpler and lower-cost way to build and run an IT infrastructure in your midsize organization,
SMARTPLAY7. Increase your Deal Size and Profitability with SmartPlays
SMARTPLAY7 Increase your Deal Size and Profitability with SmartPlays - Comstor and Panduit have joined forces to promote the power and flexibility of UCS combined with market leading energy efficient enclosures.
SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial
SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial MODEL NUMBER: SMART1000RM1U Description Tripp Lite SMART1000RM1U 1000VA / 1kVA / 800 watt line interactive,
A project to optimise quality and energy efficiency must include metering
EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,
Liebert GXT MT+ CX UPS, 1000VA - 3000VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity
Liebert GXT MT+ CX UPS, 1000VA - 3000VA Intelligent, Reliable UPS Protection AC Power for Business-Critical Continuity Liebert GXT MT+ CX UPS, 1000VA -3000VA Intelligent, Reliable UPS Protection Liebert
Uninterruptible Power Supply
96-01101 / rev. 2e / 2-2-12 Uninterruptible Power Supply EXCEPTIONAL SUPPORT & PROTECTION Uninterruptible Power Supply with Energy Saver design that is optimized to address the needs of A/V systems Features
JAWAHARLAL NEHRU UNIVERSITY
School of Biotechnology JAWAHARLAL NEHRU UNIVERSITY New Delhi 110 067 Tender No. JNU/SBT/DBT-BUILDER/Data Centre/2015-16 Sealed Quotation for the establishment of a Data Centre for High-End Computational
STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
Cabinet Overview Frame Material & Construction. Shelves Fan Options Cable Trays Blank Panels Brush Cable Entry
i Q S E R I E S S P E C I F I C A T I O N S P a g e s 2-5 Cabinet Overview Frame Material & Construction Quality Assurance Freestanding Specifications i Q S E R I E S B A S I C C A B I N E T F R A M E
