2 Rittal Micro Data Centre
|
|
|
- Bryce Anthony
- 10 years ago
- Views:
Transcription
1 Micro Data Centre
2 2 Rittal Micro Data Centre
3 The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure, power distribution, climate control and IT infrastructure products together into a single system platform. Complemented by our extensive range of software tools and global service, we create unique added value for all industrial applications: Production plant, test equipment, facility management and data centres. In accordance with our simple principle, Faster better worldwide, we are able to combine innovative products and efficient service to optimum effect. Faster with our Rittal The System. range of modular solutions, which guarantees fast planning, assembly, conversion and commissioning with its system compatibility. Better by being quick to translate market trends into products. In this way, our innovative strength helps you to secure competitive advantages. Worldwide thanks to global networking across 150 locations. Rittal has over 60 subsidiaries, more than 250 service partners and over 1,000 service engineers worldwide. For more than 50 years, we have been on hand to offer advice, assistance and product solutions. Rittal Micro Data Centre 3
4 4 Rittal Micro Data Centre
5 Security safe as Micro Data Centre In addition to the physical cover in the form of an IT security safe, the confi guration components listed below complement the Rittal safe and transform it into a fully fi tted Micro Data Centre. Robust, fl exible racks especially for server and network technology Effi cient climate control solutions in a range of designs and outputs IT-specifi c power distribution Networkable monitoring and security solutions with the CMC III system Early fi re detection and automatic rack fi re extinguishing Rittal Micro Data Centre 5
6 Benefits of Micro Data Centres Level E Complete solution in the smallest possible space and in next to no time No need for expensive upgrades to existing premises Effi cient cooling and extinguishing solution High level of protection for your IT Maximum security in the Rittal range of Micro Data Centres Optimum protection concept for one or more server rack solutions for small and medium-sized enterprises Modular layout for installation in hard-to-access locations and for retrospective enclosure of existing IT structures Future-proof investment thanks to the options of extendibility, dismantling and re-assembly System-tested security and a high level of protection; testing has been carried out by accredited institutes and confi rmed with test reports Modifi ed air baffl e plates for optimum air routing, for effi cient cooling of the Micro Data Centre 6 Rittal Micro Data Centre
7 Benefits of Micro Data Centres Level B Solid protection for your IT Optimum protection concept for a server rack Modular layout for installation in hard-to-access locations Form-fi t connection with the stable TS 8 framework structure Front and rear mm (19 ) level of the TS IT rack already included with the supply Lower weight than the Micro Data Center Level E Tested security testing has been carried out by accredited institutes and confi rmed with test reports Level A Solid protection for small IT applications Ready-installed safe as a complete system Integral cooling Integral TS 8 frame structure with front and rear pairs of mm (19 ) mounting angles Base/plinth with ground clearance Tested safety The tests were carried out as system tests and confi rmed via test reports Rittal Micro Data Centre 7
8 Overview of Micro Data Centres Requirement-based security Level E Usable U 42/47 Usable interior depth mm 1000/1200 Colour of enclosure/service door RAL 7035 Colour of operator door RAL 9005 Fire protection Fire resistance class F 90 to DIN 4102 Part 2, compliance with limits ΔT < 50 K, rel. humidity < 85% over 30 minutes 1) Burglar resistance WK II tool attack analogous to DIN V ENV 1630/ /WK II 4) WK III tool attack analogous to DIN V ENV 1630/ /WK II 3) WK IV tool attack analogous to DIN V ENV 1630/ /WK II 3) Protection category IP 56 to IEC ) Smoke protection Based on DIN : ) Modularity May be enclosed with the system operational Extendibility 1) The Micro Data Centre was tested as a system. 2) The critical connection points were tested as a system. 3) The single safe was tested as a system with single-leaf doors and mechanical lock. 4) The single safe was tested as a system with one single-leaf door and one bifold door and mechanical lock. 8 Rittal Micro Data Centre
9 Overview of Micro Data Centres Level B Level A 42/ / RAL 7035 RAL 7035 RAL 9005 RAL 9005 Fire resistance class EI 90/F 90 to DIN EN : 1999 / based on DIN :1997 2) Fire resistance class F 90 to DIN 4102 Part 2, compliance with limits ΔT < 50 K, rel. humidity < 85% over 10 minutes 1) RC 2 tool attack analogous to DIN EN 1630/ /RC 2 3) WK II tool attack analogous to DIN V ENV 1630/ /WK II 1) IP 56 to IEC : ) IP 55 to IEC ) Based on DIN EN : ) Safe is supplied assembled including cooling unit Rittal Micro Data Centre 9
10 Micro Data Centre Level E Applications: A high level of protection against potential physical threats for IT Targeted confi guration components transform into a complete Micro Data Centre Benefits: As well as facilitating installation in poorly accessible sites, the modular design also makes it possible to retrospectively enclose existing IT structures. Extendibility, dismantling and re-assembly mean targeted, future-safe investments. Tested security testing has been carried out by accredited institutes and confi rmed with test reports Protection standards: Fire protection fi re resistance class F 90 to DIN 4102 Part 2 Compliance with limit values ΔT < 50 K, relative humidity 85% for 30 minutes Burglar resistance WK II, III and IV, tool attack analogous to DIN V ENV 1630/ / WK II Smoke protection based on DIN : Material: Sheet steel, coated Colour: Enclosure and service door: RAL 7035 Operator door: RAL 9005 Protection category IP to IEC : IP 56 Supply includes: Micro Data Centre with operator door and service door Cable entry in both side elements Both doors with key lock Optional: Choice of door hinges Bifold doors Different cable entry systems Cable entry additionally in the top or base unit Different lock variants Supporting structure 1060 T3 T Note: The Micro Data Centre is confi gured on a project-specifi c basis B2 T2 H2 B1 H1 Technical details: Available on the Internet. U External dimensions mm Width (B1) Height (H1) Depth (T1) Depth (T3) Width (B2) Internal dimensions mm Height (H2) Depth (T2) Model no. (Safe is confi gured on a project-specifi c basis) Empty weight excluding cooling unit and excluding rack approx. kg Accessories Fire alarm and extinguisher system DET-AC/EFD Plus see page 18 see page 18 see page 18 see page 18 CMC monitoring system see page 19 see page 19 see page 19 see page 19 PSM Power System Module busbar see Internet PDU Power Distribution Unit see Internet Split cooling solutions from page 15 from page 15 from page 15 from page 15 LCP Liquid Cooling Package, rack depth 1000 mm see Catalogue 33, page 461 Standard protection from: Fire Extinguishing water Corrosive gases Vandalism Unauthorised access Dust Theft/burglary 10 Rittal Micro Data Centre
11 Operator door L/h DIN door hinge R/h DIN door hinge Bifold door Options for Micro Data Centre Level E Service door L/h DIN door hinge R/h DIN door hinge Bifold door Cable entry Soft duct 1) in both side elements Hard duct 2) in both side elements Cable box 3) in both side elements Hard duct 2) in top element Hard duct 2) in base element 1) Size of soft duct: approx. 267 x 165 mm For fi re protection reasons, the duct may be confi gured up to a max. of 60% with cable up to a diameter of 15 mm and conduits up to a diameter of 18 mm. 2) Size of hard duct: 2 panels each 120 x 120 mm 3) Size of cable box: Cables up to a diameter of 15 mm and hoses up to a diameter of 44 mm may be routed through the cable box. No conduits may be routed through the cable box. Locks Electronic combination lock Key lock with 2 keys Electronic combination lock 1) for activation via an access control system supplied by the customer 1) First code, second code and double code allocation possible. Key-based opening for inspection purposes supported. TS-IT rack with air baffle plates Width mm Height mm Depth mm Included with the supply Optional Supporting structure Included with the supply Optional Steel supporting structure to compensate for the raised fl oor height when siting the modular safe on the bare fl oor. The height of the supporting structure is selectable between 100 mm and 1000 mm. Steel supporting structure to compensate for the raised floor height when siting the modular safe on the bare fl oor. The supporting structure has a fi re-proof covering. The height of the supporting structure is selectable between 100 mm and 1000 mm. Rittal Micro Data Centre 11
12 Micro Data Centre Level B Applications: Basic protection against potential physical threats for IT components. Targeted confi guration components transform the safe into a complete Micro Data Centre Benefits: Modular layout for installation in hard-to-access locations Lower weight than the Micro Data Centre Level E Tested security testing has been carried out by accredited institutes and confi rmed with test reports. Protection standards: Fire protection fi re resistance class EI 90/F 90 to DIN EN : 1999 based on DIN EN : 1997 Burglar resistance RC 2, tool attack analogous to DIN EN 1630/ /RC 2 Smoke protection based on DIN EN : Material: Sheet steel, coated Colour: Enclosure and rear door: RAL 7035 Operator door: RAL 9005 Protection category IP to IEC : IP 56 Supply includes: Security safe with integral TS 8 frame Front and rear mm (19 ) level Adjusted air baffl e plates Every side element is prepared for one cable entry at the bottom and one cable entry at the top Operator and service door with swing-lever handle and semi-cylinder Optional: Choice of door hinges Bifold doors Different cable entry systems Cable entry additionally in the top and base element Different lock variants Supporting structure with fi re protection T3 T1 Note: The Micro Data Centre is confi gured on a project-specifi c basis B2 T2 H2 B1 H1 Technical details: Available on the Internet. U Width (B1) External dimensions mm Height (H1) Depth (T1) Depth (T3) Width (B2) Internal dimensions mm Height (H2) Depth (T2) Model no. (Safe is confi gured on a project-specifi c basis) Empty weight excluding cooling unit approx. kg Accessories Fire alarm and extinguisher system DET-AC/EFD Plus see page 18 see page 18 see page 18 see page 18 CMC monitoring system see page 19 see page 19 see page 19 see page 19 PSM Power System Module busbar see Internet PDU Power Distribution Unit see Internet Split cooling solutions from page 15 from page 15 from page 15 from page 15 LCP Liquid Cooling Package, rack depth 1000 mm see Catalogue 33, page 461 Standard protection from: Fire Extinguishing water Corrosive gases Vandalism Unauthorised access Dust Theft/burglary 12 Rittal Micro Data Centre
13 Operator door L/h DIN door hinge R/h DIN door hinge Bifold door Options for Micro Data Centre Level B Service door L/h DIN door hinge R/h DIN door hinge Bifold door Cable entry Soft duct 1) in both side elements Cable box 2) in top element Cable box 2) in base element Cable box 2) in both side elements 1) Size of soft duct: approx. 267 x 165 mm For fi re protection reasons, the duct may be confi gured up to a max. of 60% with cable up to a diameter of 15 mm and conduits up to a diameter of 18 mm. 2) Size of cable box: Cables up to a diameter of 15 mm and hoses up to a diameter of 44 mm may be routed through the cable box. No conduits may be routed through the cable box. Locks Swing lever handle with interchangeable semi-cylinder Swing lever handle with electronic lock for external activation Swing lever handle with electronic lock with combination code Supporting structure Included with the supply Optional Steel supporting structure to compensate for the raised fl oor height when siting the modular safe on the bare fl oor. The supporting structure has a fi re-proof covering. The height of the supporting structure is selectable between 100 mm and 1000 mm. Rittal Micro Data Centre 13
14 Micro Data Centre Level A Applications: Protection for servers and storage applications Protection for business-critical data Storage of personal data, e.g. doctors' surgeries or tax advisors Benefits: Complete system with built-in cooling and mm (19 ) rack High level of operational and service-friendliness thanks to the two-door system Compatibility with other infrastructure elements Tested security testing has been carried out by accredited institutes and confi rmed with test reports Protection standards: Fire resistance class F 90 to DIN 4102 Part 2, compliance with limits ΔT < 50 K, rel. humidity < 85% over 10 minutes Burglar resistance WK II, tool attack analogous to DIN V ENV 1630/ /WK II Material: Sheet steel, coated Colour: Enclosure and service door: RAL 7035 Operator door: RAL 9005 Protection category IP to IEC : IP 55 Supply includes: Security enclosure with operating and service doors (three-point locking) Cable entry in both side elements Cooling 2.4 kw designed as a split unit Technical details: Available on the Internet. T3 T2 B1 B2 H2 T1 H1 U 15 Cooling capacity kw 2.4 Width (B1) 806 External dimensions mm Height (H1) 1699 Depth (T1) 1270 Depth (T3) 2746 Width (B2) 620 Internal dimensions mm Height (H2) 827 Depth (T2) 1024 Weight excluding internal fi ttings, including climate control unit approx. kg 360 Model No. Micro Data Centre with built-in mm (19 ) rack Model No. Micro Data Centre without built-in mm (19 ) rack Accessories mm (19 ) rack, 15 U, depth 1000 mm Fire alarm and extinguisher system DET-AC/EFD Plus see page 18 CMC monitoring system see page 19 PDU Power Distribution Unit with busbar see Internet Standard protection from: Fire Extinguishing water Vandalism Unauthorised access Dust Theft/burglary 14 Rittal Micro Data Centre
15 Compact split cooling solution for Micro Data Centres Separate, hermetically sealed internal and external circuits No ingress of dust or smoke gases The internal and external unit are connected to one another via coolant lines and control cables and shielded for fi re protection. Air routing inside the Micro Data Centre is horizontal. Modifi ed air baffl e plates ensure targeted air routing. By separating the cold side from the hot side, air shortcircuits are avoided, and the effi ciency of cooling is enhanced. Used in rooms with climate control in the building or adequate ventilation, and low or no noise level requirements. The evaporator coil is fastened to the side panel on the inside of the Micro Data Centre, and the external unit on the service door. Colour: RAL 7035 Protection category IP to IEC : External circuit IP 24 Internal circuit IP 54 Supply includes: Internal unit External unit Coolant lines Data and power supply cables Flexible coolant lines inlet/return Power supply 4 Data cable 5 2 External unit Internal unit Model No Rated operating voltage V, Hz 400/460, 3~, 50/60 Dimensions mm Useful cooling output Q. K to DIN 3168 W x H x D external unit 500 x 1580 x 231 W x H x D internal unit 804 x 1544 x 100 L 35 L 35 L 35 L W/3090 W 2070 W/2300 W 4000 W/4010 W 3020 W/3250 W Rated current max. 3.3 A/3.5 A 4.1 A/4.8 A Start-up current 14.2 A/14.7 A 15.2 A/15.8 A Pre-fuse T A A Motor circuit-breaker Power consumption P el to DIN 3168 L 35 L 35 L 35 L W/1615 W 1525 W/1920 W 1620 W/2125 W 1825 W/2835 W Refrigeration factor e = Q. /P K el L 35 L Refrigerant R134a, 1500 g R134a, 2900 g Permissible operating pressure p. max. 28 bar 25 bar Temperature and setting range +20 C to +55 C +20 C to +55 C Noise level db (A) < 70 < 72 Weight External unit 65 kg 65 kg Internal unit 70 kg 70 kg Colour RAL 7035 RAL 7035 Temperature control Comfort controller (factory setting +25 C) Rittal Micro Data Centre 15
16 Split outdoor cooling solution for Micro Data Centres The internal circuit of the cooling unit is attached to the side panel inside the Micro Data Centre The external unit is positioned outside of the building. Internal and external units are connected to one another via coolant lines and control cables The hot air from the servers is drawn in at the rear, and the cooled air is expelled in front of the mm (19 ) level The waste heat is routed directly to the outside. As a result, room ventilation or airconditioning is not necessary Colour: RAL Supply includes: Internal unit External unit Coolant lines Data and power supply cables Copper pipe inlet/return Power supply Data cable External unit Internal unit Model No Redundancy Rated operating voltage V, Hz 230 V, 50 Hz, 1~ 400 V, 50 Hz, 3~ 230 V, 50 Hz, 1~ (2 x) 400 V, 50 Hz, 3~ (2 x) Dimensions of external unit, mm W x H x D 795 x 610 x x 680 x 340 (2 x) 795 x 610 x x 680 x 340 (2 x) Useful cooling output Q. to DIN 3168 L 35 L W 5000 W 2400 W 5000 W K Rated current max. 3.8 A 4.1 A 3.8 A 4.1 A Start-up current per unit 19.5 A 35 A 19.5 A 35 A Pre-fuse T 16 A 3 x 16 A 16 A (2 x) 3 x 16 A (2 x) Refrigerant R410 a Temperature and setting range 15 C to +35 C Weight External unit 38 kg 74 kg 2 x 38 kg 2 x 74 kg Internal unit 59 kg 59 kg 63 kg 66 kg Colour RAL 7035 Accessories Coolant line incl. electric control cable for 2400 W, length 20 m Coolant line incl. electric control cable for 5000 W, length 20 m Rittal Micro Data Centre
17 Split outdoor cooling solution with inverter technology Targeted speed control of the compressor. The volume of refrigerant is regulated via the electronic expansion valve Up to 40% energy saved. The cold air is expelled in front of the mm (19 ) level by the internal unit (evaporator coil), while the hot air is drawn in at the rear Colour: RAL 7035 Suppy includes: 4 Internal unit External unit Coolant lines 5 Data and power supply cables Copper pipe inlet/return Power supply Data cable Control box Operating unit Switch box External unit Internal unit Model No Redundancy Rated operating voltage V, Hz 230 V, 50 Hz, 1~ 230 V, 50 Hz, 1~ (2 x) Dimensions of external unit, mm W x H x D 900 x 795 x x 795 x 320 (2 x) Useful cooling output Q. K to DIN 3168 L 18 1) /L 35 L 18/L W 7030 W 7850 W 7030 W Rated current max A 13.9 A Start-up current 36 A 36 A Pre-fuse T 25 A 25 A (2 x) Refrigerant R 410a R 410a Temperature and setting range 15 C to +43 C 15 C to +43 C Noise level db (A) db (A) Weight External unit 63 kg 63 (2 x) kg Internal unit 70 kg 70 (2 x) kg Colour RAL 7035 Also required Heat exchanger (evaporator coil) ) 1) Server inlet temperature 2) 2 heat exchangers are required. Rittal Micro Data Centre 17
18 Fire alarm and extinguisher system DET-AC/EFD Plus Benefits: Early fi re detection Automatic extinguishing Innovative extinguisher gas NOVEC 1230 Eco-friendly Uncritical for IT components mm (19 ) rack mount with just 1 U Colour: RAL 7035 DET-AC Plus Compact fi re alarm and active extinguisher system with smoke extraction system, built into one height unit. The detection system is identical to that used in the EFD Plus system. Fire extinguishing with the extinguisher gas NOVEC 1230 is automatically activated when a main alarm is triggered. With the extinguisher gas supply provided, a volume of up to 3 m 3 can be extinguished. The collective fault signal and the alarms may be forwarded to the CMC. DET-AC Plus slave In conjunction with the DET- AC Plus slave system, up to fi ve bayed enclosures may be extinguished. In addition to the DET-AC Plus unit, a DET- AC Plus slave unit is used for each additional enclosure and contains the extinguisher gas for one enclosure. The pipework from the DET-AC Plus system is laid in all enclosures to facilitate detection. EFD Plus Compact early fi re detection system with active smoke extraction system. The integral fan continuously extracts the air from the enclosure, and passes it over two smoke detectors. The fi rst smoke detector is extremely sensitive and triggers a pre-alarm. The second smoke detector triggers the main alarm. Photo shows a confi guration example with equipment not included in the scope of supply. Fire alarm and extinguisher system DET-AC Plus Add-on unit DET-AC Plus slave Early fire detection system EFD Plus Width (B) mm (19 rack mount) (19 rack mount) (19 rack mount) Height (H) mm 44 (1 U) 44 (1 U) 44 (1 U) Depth (T) mm Weight kg approx. 15 approx. 12 approx. 8 Model No Protection category IP 20 IP 20 IP 20 Ambient temperature (operation) +10 C to +35 C +10 C to +35 C +10 C to +35 C Battery storage 10 C to +50 C 10 C to +50 C 10 C to +50 C Operating voltage 100/240 V AC 50/60 Hz 24 V DC 100/240 V AC 50/60 Hz Uninterruptible mains electricity operation 2 x 12 V; 2.2 A/approx. 4 h 2 x 12 V; 2.2 A/approx. 4 h 2 x 12 V; 2.2 A/approx. 4 h Connections 3 RJ 12 connectors for connecting to the CMC, alternatively 3 relay outputs, max. contact load 24 V DC/0.5 A Sensors 2 different scattered-light sensors 2 different scattered-light sensors Display LCD display LCD display with plain text information with plain text information No. of slave modules max. 4 max. 5 No. of monitored enclosures max. 5 max. 5 Extinguisher gas NOVEC 1230 NOVEC 1230 Fill volume of extinguisher gas 3.2 kg 3.2 kg Admissible max. protection volume 3 m³ 3 m³ Also required Pipe kit Cat. 33, page RJ 12 cable for alarm relaying to CMC, packs of ) ) ) 775 Access sensors Depth-variable slide rails ) 2 packs are required. 18 Rittal Micro Data Centre
19 CMC III monitoring system CMC III monitoring system The CMC III monitoring system controls physical parameters such as the temperature inside the Micro Data Centre. The user defi nes limits for the various parameters. These are fully automatically monitored by the CMC. If the limits are exceeded or undercut, the CMC emits an alarm which may optionally be notifi ed via or SMS. The system may also be connected to the customer network (via OPC/SNMP) to represent messages or values directly in the control room system (SCADA/BMS/NMS). The CMC III system is plug & play-ready, sensors are detected automatically, and the Web user interface is easy to use even with no prior knowledge. The CMC Compact basic unit is available for small monitoring units, and supports the connection of up to four sensors. The CMC III Processing Unit for larger monitoring units supports the connection of up to 32 sensors. There is a 24 V DC power supply with a redundant design, but power can also be supplied via the integral Power over Ethernet (PoE). In addition to temperature monitoring, both the alarms and collective fault signal from the fi re alarm and extinguishing system, as well as the fault signalling from the climate control system, may be switched to the CMC. Packs of Model No. CMC III Processing Unit Compact Power pack V AC to 24 V DC Mounting unit, 1 U USB programming cable CAN-bus cable 0.5 m CAN-bus cable 1.0 m CAN-bus unit for CMC-TC sensors Temperature sensor Connection cable Note: For more CMC III sensors, see Catalogue 33, page 773. Application example for monitoring a Micro Data Centre with fire alarm and extinguisher system CMC III Processing Unit Compact (with front infrared access sensor, temperature sensor, 2/1 inputs/outputs) Power pack V AC to 24 V DC Mounting unit, 1 U Programming cable USB CAN-bus connection cable 1 m CAN-bus connection cable 0.5 m CAN-bus sensor Temperature sensor Connection cable Rittal Micro Data Centre 19
20 Enclosures Power Distribution Climate Control IT Infrastructure Software & Services /E53B RITTAL GmbH & Co. KG Postfach 1662 D Herborn Phone +49(0) Fax +49(0) ENCLOSURES POWER DISTRIBUTION CLIMATE CONTROL IT INFRASTRUCTURE SOFTWARE & SERVICES
Micro Data Center IT protection in the smallest possible space
Micro Data Center IT protection in the smallest possible space 2 Rittal Micro Data Center The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have bundled
RiMatrix S Make easy.
RiMatrix S Make easy. 2 RiMatrix S Rittal The System. The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure, power
IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre
IT infrastructure Efficiency-boosting solutions nextlevel for data centre 2 Rittal IT infrastructure The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind,
CRAC Precision climate control units for data centres
CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have
Security rooms for data centres
Security rooms for data centres 2 Rittal Security rooms The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure,
COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C
COOLS conditioned server - racks for direct installation into the room COOLSIDE box INVERTER R410A E C 2 COOLSIDE box GENERAL FEATURES COOLSIDE BOX is a split system consisting of an outdoor motocondensing
THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER
Your Complete Turnkey Server Room Air Condition UPS THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER AVAILABLE IN WATER AND GAS SYSTEM MODEL AIR-CONDITIONED CABINET EXCELLENT TEMPERATURE CONTROL FOR
Rittal the time has come...
Rittal the time has come...... for the Data Centre of the future Sustainable energy efficiency! Energy Outstanding climate protection and energy efficiency with Green IT. Modular, scalable IT infrastructures
Data Centre Solutions
Issue 6 Data Centre Solutions RACKS POWER COOLING MONITORING SECURITY SERVICE & SUPPORT The simple route to the perfect data centre Data centres are complex systems. Software, hardware and IT infrastructure
Rittal TopTherm fan-and-filter unit
Rittal TopTherm fan-and-filter unit System Climate Control More pressure. Higher air flow rates. 2 Assembly without tools Straightforward assembly, exchange and maintenance with no need for tools of any
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
JAWAHARLAL NEHRU UNIVERSITY
School of Biotechnology JAWAHARLAL NEHRU UNIVERSITY New Delhi 110 067 Tender No. JNU/SBT/DBT-BUILDER/Data Centre/2015-16 Sealed Quotation for the establishment of a Data Centre for High-End Computational
Material test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
Technical specifications. Containerized data centre NTR CDC 40f+
Technical specifications Containerized data centre NTR CDC 40f+ CONTENT 1 THE PURPOSE OF CDC... 3 2 BASIC PROPERTIES... 4 2.1 EXTERNAL DIMENSIONS... 4 2.2 INSTALLATION REQIREMENTS... 4 2.3 ELECTRICAL CONNECTION
SERVER ROOM CABINET INSTALLATION CONCEPTS
SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS ZPAS 169 EXAMPLES OF SERVER ROOMS PROJECTS WITH ZPAS CABINETS Data Box in the
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels
Incubator with mechanical convection
BF series 400 Incubators and cooling incubators Incubator with mechanical convection The BINDER incubator of the BF series with mechanical convection is suitable for all gentle incubation applications,
(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently
(68.52) X June 2000 Supercedes February 2000 xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM.... we look @ business differently XENEX SYSTEM ARCHITECTURE Note: This schematic is for guidance only please
Climate chamber with illumination
KBWF series (E5.2) Climate chambers with illumination Climate chamber with illumination The BINDER climate chamber with illumination of the KBW series achieves homogeneous light distribution with its natural
How To Make A Fronius Cl Power Inverter
Fronius CL PV central inverter with Fronius MIX concept Modular system. Maximum yield. The Fronius CL combines high-yield power electronics with the unique, modular system design of up to 15 identical
White Paper Data Centre in a Standard Container
White Paper Data Centre in a Standard Container Contents Contents... 1 List of illustrations... 3 List of tables... 3 Executive summary... 4 Introduction... 5 Objective and requirement... 6 Rittal Data
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
DIGITUS Network & Server Cabinets. UNIQUE Series
DIGITUS Network & Server Cabinets UNIQUE Series Benefits - Server Rack 4-Point locking system front door 3-point locking system rear door Swing handle lock with profile zylinder in front and rear door
Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems
Knürr CoolAdd The universal retrofit solution against overheating in server racks Rack & Enclosure Systems Knürr CoolAdd When cold air is no longer enough! Data centers are subject to constant changes:
White Paper Rack climate control in data centres
White Paper Rack climate control in data centres Contents Contents...2 List of illustrations... 3 Executive summary...4 Introduction...5 Objectives and requirements...6 Room climate control with the CRAC
Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009
Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal
CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS
CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS Air / Water / DX Cooled Cabinet Solutions Mini Data Centre All in One Solution: Where there is a requirement for standalone computing and communications, or highly
Standardised Data centres. Sales presentation
Standardised Data centres 1 Standardised Data Centres l Motivation ll Change of paradigm lll Rittal s Data centre concept lv Benefits V Summary Standardised Data Centre Motivation Does every data centre
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient
Visions become real. Temperature control and cooling systems. The innovative and reliable solution
Temperature control and cooling systems The innovative and reliable solution With our PulseTemp equipment you have the option of up to 72 cooling circuits in the impulse cooling, temperature control, temperature
MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4
CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,
Installation & operating instructions
Installation & operating instructions Isotherm Cruise & Drawer marine freezers Type: CR 63F INOX, CR 65F, CR 65F INOX, CR 90F, CR 90F INOX, DR 55F INOX Indel Webasto Marine USA, Inc. 3400 Gateway Drive
Miracel 19 rack platform for data center, telecommunication and network technology. Rack & Integrated Enclosure Systems
Miracel 19 rack platform for data center, telecommunication and network technology Rack & Integrated Enclosure Systems The Miracel innovation rack multi-talented, distinguished, integrative The Miracel
york air-conditioning products Residential & VRF News 2015
york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter
Knürr Miracel. Knürr Miracel. 19 Network and Server Rack Platform 1.12 to 1.22 1.11
Knürr Miracel 19 Network and Server Rack Platform 1.12 to 1.22 1.11 19" Server Rack: Knürr Miracel Strong points 1.13 Knürr Miracel ASP ASP/Server Rack 1.16 Knürr Miracel Server Rack 1.18 Knürr Miracel
How To Use Rittal'S Rizone
RiZone Data Centre Infrastructure Management Enclosures Power Distribution Climate Control IT INFRASTRUcTURe SOFTWARE & SERVICEs RiZone Data Centre Infrastructure Management What can the RiZone Data Centre
Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75
Specifications COOLING ONLY / HEAT PUMP 005 006 007 Capacity (Eurovent) Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Nominal input (Eurovent) Cooling kw 1.89 2.35 2.95 Heating kw 1.97 2.24 2.83 EER
3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.
ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2
Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE
Hitachi Air Conditioning Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE Contents Page 04 Product Range 08-09 RAC Summit Wall Mounted 10 RAC Shirokuma Wall mounted 11 RAC S Series - Wall
Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC
TM 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM D400E Data Module (60Hz) The EDGE D400E is designed to meet high power density requirements for both the HPC and Web Scale environments while
RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features
RKE Heat recovery unit from 200 to 6800 m 3 /h General features RKE heat recovery units are suitable for residential and commercial applications and offer a real energy saving in forced ventilation plants,
IPSIP M series-m Modular Data Center
IPSIP M series-m Modular Data Center IPSIP MODULAR TECHNOLOGIES. 1 With the rapid development of cloud computing and mobile Internet businesses, the growth of IT density and energy consumption are bringing
Weiss Mobile Air Conditioning Systems
Weiss Mobile Air Conditioning Systems SHELTER AIR CONDITIONING System Weiss Umwelttechnik GmbH Simulationsanlagen Messtechnik Worldwide... Weiss Umwelttechnik GmbH is one of the world s most important
Comparative study for cables and busbars
Comparative study for cables and busbars Preliminary considerations To compare the prices of two categories of product as different as traditional cables and busbars, it is necessary to make some preliminary
EasiCool. 6-64kW DX AIR. www.airedale.com. Precision Air Conditioning
Precision Air Conditioning DX / CW EasiCool 6-64kW ENHANCED EASICOOL RANGE: + Up to 37% increase in EER + Up to 8% more cooling kw/m 2 Compared with our previous generation EasiCool units HFC R410A HFC
Heating oven with mechanical convection
FD series 53 Drying ovens / Heating ovens Heating oven with mechanical convection A BINDER FD series heating oven is always used when fast drying and sterilization is required. Thanks to its fully homogeneous
CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60
CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.
CoolTeg Plus Chilled Water (CW) version: AC-TCW
version: 12-04-2013 CONTEG DATASHEET TARGETED COOLING CoolTeg Plus Chilled Water (CW) version: AC-TCW CONTEG, spol. s r.o. Czech Republic Headquarters: Na Vítězné pláni 1719/4 140 00 Prague 4 Tel.: +420
ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA
MRO Modularne Razdelilne Omare d.o.o. ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 2, 000 Ljubljana, LOVENIA MC GENERAL When to use? MC - modular switchgear cabinets are type-tested, factory built switchgears,
Photovoltaic Solar Energy Unit EESFB
Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality
Adsorption air dryers ADS 1 215
Adsorption air dryers ADS 25 INDUSTRY CUSTOMER SERVICE COMPRESSED AIR AIR INTAKE 20 C 70% UR 760 mm Hg 2 grh 2 O/m 3 AIR PRESSURE 0 bar COOLING SYSTEM 30 C 00% UR 0 bar 2,8 grh 2 O/m 3 A compressor that
Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes
Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,
NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements
NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems Safe energy distribution that meets the highest industrial requirements NATUS switchgear systems your advantages minimal use of insulant
RRV934. Multi-controller. Synco living
s 2 709 Synco living Multi-controller RRV934 RF-based multi-controller For precontrol of up to 2 room groups For control of ventilation plant with up to 3 stages RF communication based on KNX standard
Vacuum drying oven for non-flammable solvents
VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.
Your own power station: For continuous power
Mass Combi Ultra Your own power station: For continuous power Compact and lightweight inverter/battery charger Seamless switching between generator and grid Separate second charger Integrated MPPT solar
LG Electronics AE Company, Commercial Air Conditioning
www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,
Climate Test Chamber. System Weiss. Type WK3-2000/40
Climate Test Chamber System Weiss Type WK3-2000/40 Tel. 0552561066 Technical description WK3-2000/40 Page 1/16 FACTS Operation, monitoring and documentation of the test chamber are realised by an integrated
How To Build A T7 Rack For Information Technology
THE NEXT GENERATION RACK FOR INFORMATION TECHNOLOGY THE RACK CABINET FOR INFORMATION TECHNOLOGY T7, THE HI-TECH HEART OF THE BLADESHELTER SYSTEM The real answer to the requirements of: Safety Versatility
FOXAIR 60/50 ALL MODELS
FOXAIR 60/50 ALL MODELS OPERATION AND SERVICE MANUAL UNIT WEIGHT - ALL MODELS APPROX. 300 POUNDS FOXTRONICS, INC. 38 L x 28 W x 24 H Love Field-Dallas TX MADE IN THE USA 3448 West Mockingbird Lane Dallas,
Knürr Smaract. Knürr Smaract. CompactRack
CompactRack Features Ample space for components and cabling provided in an efficient, compact design. The innovative frame concept with triangular extrusions ensures low weight while maintaining high stability.
CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series
Programmable Terminal NPSeries Easy Setup with the Low-cost, Compact NP Series Simpler and More Versatile.OMRON s Compact NP Series Connect! Easier connection to OMRON PLCs and Temperature Controllers,
IV. Rear Mount System
Mobile Climate Control 45 MCC Reference Manual 2014 PN: 89-3069 Rearmount Air Conditioning System Eco RM Capacity, Reliability, and Serviceability MCC Eco RM unit, selected as preferred equipment by leading
Cold Room & Refrigeration System (Casserole Assembly) No of units: 1
Technical Specifications Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 For chiller storage of all sorts of items Chiller storage temperature: 2-5 C Provides excellent thermal efficiency
technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air
technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t
Air conditioning unit Saphir vario. 2. Product information for the new Truma air conditioning unit. Comfort on the move
Air conditioning unit 2. Product information for the new Truma air conditioning unit October 2006 Edition Comfort on the move Air conditioning systems Manoeuvring systems Energy systems Heating systems
Huawei IDS2000 Modular Data Center Solution
CloudPower Huawei IDS2000 Modular Data Center Solution HUAWEI TECHNOLOGIES CO., LTD. With the rapid development of cloud computing and mobile Internet businesses, the growth of IT density and energy consumption
Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks
Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks 19-inch Industry Standard Rack Systems The trend to consolidation as a result of virtualization and optimization
Daikin Altherma hybrid heat pump. The natural combination
Daikin Altherma hybrid heat pump The natural combination Daikin Altherma hybrid heat pump, the natural combination Why choose Daikin Altherma hybrid heat pump? What the customer wants: more energy efficient
Voltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage [kv] 28 50 Rated lightning impulse withstand voltage [kv] 75 125
Standards and Regulations IEC 62271-200 ; VDE 0671-200 ; BS EN 62271-200 Technical Data MC3-12 MC3-24 Voltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage [kv] 28 50 Rated
Heating, air-conditioning, cooling
Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft
BLADE S-MAX Cabinet for Blade Server
Cabinet for Blade Server 1 2 Overview Material specification Corner verticals: 1.5 mm steel End frames: 1.5 mm steel Panel mounts: 2.0 mm steel Panel mount supports: 1.5 mm steel Side panels, door and
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
TrueAlarm Fire Alarm Systems
TrueAlarm Systems UL, ULC, CSFM Listed; FM Approved* Network Annunciators; es Features Provides a dedicated local area network (LAN) for connection of a TrueSite workstation server to remote clients: es
SMART SHELTER CONTAINER
Da ta Ce nt er Total Flexibility and Security in a Modular Data Center Advantages Environmentally Friendly Short Delivery Time Smart Shelter Container (SSC) solution provides a fully functional Data Center
Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate
1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration
III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014
III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014 III.1. Large Roof Mount PN: 89-3037 Roof Mount Unit Eco 136 Parallel roof mount Air-conditioning and ventilation systems The Eco 136
DATA CENTRES POWERED BY EXCEL
DATA CENTRES POWERED BY EXCEL MAXIMISE EFFICIENCY BOOST PERFORMANCE INCREASE R.O.I. WITHOUT COMPROMISE Excel is a world-class premium performance end-to-end infrastructure solution. Designed, manufactured,
FIREDEX 2200. Conventional Fire Panels
68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class
LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy
LG Air conditioning Company Multi V Water Ⅱ Air Conditioning Academy 1.1 What is Multi V Water II? High Performance Prospect rights Water pipe Refrigerant pipe Indoor unit Beautiful Exterior Convenience
Data Center Rack Systems Key to Business-Critical Continuity. A White Paper from the Experts in Business-Critical Continuity TM
Data Center Rack Systems Key to Business-Critical Continuity A White Paper from the Experts in Business-Critical Continuity TM Executive Summary At one time, data center rack enclosures and related equipment
Thyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity
Liebert Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment Precision Cooling For Business-Critical Continuity The Intelligent Data Center Cooling Solution: Liebert Trust the industry
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
APC APPLICATION NOTE #112
#112 Best Practices for Deploying the InfraStruXure InRow SC By David Roden Abstract The InfraStruXure InRow SC (ACSC100 and ACSC101) is a self-contained air conditioner for server rooms and wiring closets.
Optimum Climate Control For Datacenter - Case Study. T. Prabu March 17 th 2009
Optimum Climate Control For Datacenter - Case Study T. Prabu March 17 th 2009 Agenda 2 About EDEC (Emerson) Facility Data Center Details Design Considerations & Challenges Layout Design CFD Analysis Of
P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.
This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product
Commercial Gas Furnace Upflow
Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted
The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity
Liebert HPF The High Performance Floormount Indoor Package Cooling Solution Precision Cooling for Business-Critical Continuity We re Emerson Network Power, backed by Emerson, a global company that brings
DELTA3-1. Delta 3 Data Centre Rack Solution
DELTA3-1 Delta 3 Data Centre Rack Solution Contents Building on more than 50 years of British design and innovation, Cooper B-Line introduces Delta 3 ( Delta cubed ). Designed to offer M.O.R.E. to customers
ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011
, 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
The Mission Critical Data Center Understand Complexity Improve Performance
The Mission Critical Data Center Understand Complexity Improve Performance Communications Technology Forum Fall 2013 Department / Presenter / Date 1 Rittal IT Solutions The State of the Data Center Market
Workspace and storage furnishings
LISTA Compact Workspace and storage furnishings Test and inspection workstations With its modular test and inspection workstations, LISTA offers optimised solutions for modern quality assurance practices.
Linkeo 19" freestanding cabinets
87045 LIMOGES Cedex France Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 Linkeo 19" freestanding cabinets Page 1. General characteristics....1 2. Range....2 3. Technical characteristics...3
Low Voltage Switchboards The Best Technical Solution for Your Ship
The Best Technical Solution for Your Ship Wärtsilä SAM Electronics Optimal Power Distribution The uninterrupted supply of power to systems and consumers onboard modern ships is an extremly important matter.
Gree Solar Hybrid Hi Wall Inverter Air Conditioner
Gree Solar Hybrid Hi Wall Inverter Air Conditioner Utilize the natural power of the sun to heat or cool your home. Find out more at www.greeonline.com Why Choose a Solar Hybrid Inverter? The new Gree Solar
Dimensions (HxDxW) Total Cabinet Area 89.96x 39.69 x 24 in/ 2,285 x 1,008.17 x 612.77 mm 95.47x 48 x 32 in/ 2,425 x 1,219.2 x 812.
1 Compaq 10000 Series Racks The 10000 series racks are a family of 1000mm deep racks which are available in 22U, 36U, 42U and 47U 600mm widths. Compaq 10000 Series Racks provides a common, integrated platform