1 Marine Consultants & Specialist Brokers Saturation Diving System Components Equipment List Item No: Description Quantity 1 SDC (Bell) Fitting Out Mechanical Outfit Materials ( Valves, Fittings, pipework etc..) 1 Mechanical Outfit External (Labour) 1 Viewports 3 SDC Insulation / Floatation ( supply only) 1 Gas System G Size Onboard Gas Bottles 300 Bar 9 O2 Buffer Bottle 1 Plumbing / Pipework / Panels 1 Mara Diver Gas Panel 1 Onboard Gas Regulators Tescom E Analyser (PP02 Hyperbaric Analiyser) 1 CO2 Scrubbers Normal & Emergency (DH21) 2 Bibs Scotts Single Hose 4 Lung Powered Scrubbers Passive CP Electrical System Battery Pack 1 Oil Filled Electrical Junction box External 1 Electrical Penetrators 3 Viking External Lights c/w Yoke 4 External TV Camera 1 Internal Electrical Junction Box 1 Hat Lights Divex 3 LP 20 Lights c/w 1 Meter Pigtails 2 Heater (DH21) 1 Communications Internal Radio 1 Emergency Though Water Comms 1 Bell Locating Device Transponder 1 SP Phone c/w Call Generator 1 Bell Equipment Cassion Guage msw 2 Fibron Divers Umbilicals x 70m c/w Jupiter Connections 2 Fibron Bellmans Umbilical x 75m 1 UltraJewel 601 Reclaim Helmets 2 Specifications given in good faith but without guarantee. pg. 1
2 KMB 28 Bandmask 1 Bell Survival Kits 3 Drager Test Kit 1 Bell Tool Kit 1 Bailout Cylindres & Backpack X 3 3 1st Stage Reg & Bailout Whip (Posiedon) 3 Dive Harness 3 Diver Recovery Hoist 1 Pneumatic Safety Interlock 7 2 LARS c/w Umbilical and Lift Wires Winch Lloyds Classified 12 Tonne Man Riding 1 Bell Main Wire AUD 76/mtr 1 Winch 8 Tonne Man Riding / Secondary Bell Recovery Lloyds Class m Non Rotating SWR 16 mm (Guid Wire) 1 Hyd Umbilical Winch Constant Tension Lloyds Class 1 Braided Main Bell 360 /m 1 HPU's for winches 1 Hydraulic Console including local and pilot remote control 1 Design & Fabricate HRC Launch system - Lloyds Class 1 3 DDC 1 (9 Man Twin Lock Chamber) Viewports 3 Mechanical Outfitting Materials ( Valves, pipework, Fittings) 1 Electrical Outfitting Materilas ( Cable, Cable Tray, Connectors) 1 Chamber Gas System PPO 2 Analysers 2 Bibs Scotts Twin Hose 14 Bibs, BPR Divex VM A-XX 3 Chamber Electrical System Inernal Cable tray Wiring etc 1 Electrical Penetrators 4 Scrubber Emergency CES BH500 3 Roof Lights LP 20 c/w 1mtr pigtail 5 Bunk Lights LP 20 c/w 1mtr pigtail, switched 9 Chamber Enviromental Control Unit Chamber Conditioning ( HCU/3/6) main lock 1 Chamber Conditioning ( HCU3/4) entry lock 2 Chamber Communications Chamber Comms Box 2 Sound Powered Phone c/w call generator 2 Camera Static Low Light 2 Chamber fitted equipment Caisson Guage 0-320m 2 Fire Extinguisher Hy-Fex 7.5 Ltr 2 Interlocked Toilet & Hand Basin, Stainless Steel 1 Sanitary Holding Tank 1 Specifications given in good faith but without guarantee. pg. 2
3 Shower 1 Bedding (fireproof) 9 Mattresses ( Fire Proof ) 9 Temp/Humidity Guage 2 6 DDC 2 (6 Man Twin Lock Chamber) Viewports 3 Mechanical Outfitting Materials ( Valves, pipework, Fittings) 1 Electrical Outfitting Materilas ( Cable, Cable Tray, Connectors) 1 Chamber Gas System PPO 2 Analysers 2 Bibs Scotts Twin Hose 11 Bibs, BPR Divex VM A-XX 2 Chamber Electrical System Inernal Cable tray Wiring etc 1 Electrical Penetrators 4 Scrubber Emergency (UTS Unit) 3 Roof Lights LP 20 c/w 1mtr pigtail 5 Bunk Lights LP 20 c/w 1mtr pigtail, switched 6 Chamber Enviromental Control Unit Chamber Conditioning (HCU 3/6) 1 Chamber Conditioning Unit HCU 3/4 1 Plumbing, Pipework, Valves 1 Chamber Communications Chamber Comms Box 2 Sound Powered Phone c/w call generator 2 Camera Static Low Light 2 Chamber fitted equipment Bunks, Seats 7 Caisson Guage msw ( need 0-320m ) 2 Fire Extinguisher Hy-Fex 7.5 Ltr 2 Toilet & Hand Basin, Stainless Steel 1 Sanitary Holding Tank 1 Shower 1 Bedding (fireproof) 6 Mattresses ( Fire Proof ) 6 Temp/Humidity Guage Man Single Lock HRC Viewports 2 Mechanical Outfit Materials ( Valves, Fittings, Tubing etc..) 1 Electrical Outfit Materials ( Cable, connectors etc..) 1 Chamber Gas System 9 x G Size Onboard Gas Bottles ( 200 Bar ) ( 300 Bar? ) 12 PPO 2 Analysers 2 Bibs Scotts Twin Hose 13 Bibs, BPR Divex VM A-XX 2 Chamber Electrical System Emergency Battery 72 Hours Operations 1 Specifications given in good faith but without guarantee. pg. 3
4 Inernal Cable tray Wiring etc 1 Electrical Penetrators 4 Scrubber Emergency CES BH500 3 Roof Lights LP 20 c/w 1mtr pigtail 3 Bunk Lights LP 20 c/w 1mtr pigtail, switched 3 Chamber Enviromental Control Unit Chamber Coooling unit and HCU3/6 Conditioning unit 1 Chamber Communications Chamber Comms Box 2 Sound Powered Phone c/w call generator 2 Camera Static Low Light 2 Strobe, radar reflector & EPIRB 1 Chamber fitted equipment Saftey harness etc 12 Caisson Guage 0-320m 2 Fire Extinguisher Hy-Fex 7.5 Ltr 2 Rally style Seating 12 Temp/Humidity Guage 2 Lung Powered Scrubbers 13 Survival Suits, ( Thin Bear Suit ) 13 Dedicated Lifting & towing Gear 1 9 Dive Control Mechanical oufit including panel frames 1 Electrical outfit including LIMS, DP Alarms, Transformers for SDC) 1 Dive Control Gas Panels. Depth gauges 5 3 Diver Control Panel Complete, 1 02 analysers 3 C02 analysers 3 Dive Control Communications. Air radios 1 Heliox Unscramblers 2 VHF Radio & Arial/Transciever 1 TV Monitors 3 Video/DVD Recorders 2 Diver Video System 1 Deck Video System 2 19 Inch Electrical Rack 1 Black Box recorder 1 Dive Control fitted equipment Supervisors Smoke Mask with comms 1 High/Low Hot Water Alarms 1 Push Button Knife Switch, Welding/Cutting 1 10 Saturation Control Fabricate Container 1 Mechanical oufit including panel frames 1 Electrical outfit including transformers, swithc panels and cabling 1 Specifications given in good faith but without guarantee. pg. 4
5 Saturation Control Gas Panels.. 1 Chamber Gas Control Panel ( DDC 1 ) 1 Chamber Gas Control Panels ( DDC 2 ) 1 HRC/Chamber 3 Gas Control Panel ( HRC/DDC 3 ) 1 Bell Trunking Gas Control Panel 1 Gas Distribution & Mixing Panel 1 O2 Chamber Analyser 3 CO2 Chamber Analyser 3 Saturation Control Electrical Panels.. Chamber TV Monitor Rack 5 Chamber Communications Panel 3 Hyperbaric First Aid Kit 1 Oxy Viva 1 B.A Masks 2 Head Sets With Mike 3 Diver Entertainment System 1 Environment Control Machinery and Gas Recovery 11 System Dyfog Water Deluge System - Lloyds Approved 1 Main Electircal Distribution Board IP56 1 Electrical outfitting materials 1 3 Diver Hot Water Unit, Electric 2 CMU 02 plus Life support units 3 CEC-02 Environmental Life Support Controller Package 5 PWS-01 Kinergetics Potable Water Skid 1 Gasmizer 3 Divers Reclaim ( Airdriven ) 1 Gas Transfer panels for onboard gas storage 4 Corblin Refurbished Gas Transfer Compressors 2 Haskel Gas Booster Package 1 12 HRC Support Container 10' Air Conditioned c/w Lifting Points + Slings 1 Air Conditioner 1 HRC Control Panel 1 Communication Radio/Panel 1 TV Monitors x 2 2 Emergency HRC Umbilical 1 O2 Analyser- Analox 1 CO2 Analyser - Analox 1 Environmental Control System 1 13 Divers Apparel / Equipment 70m divers excursion umbilical (spare) c/w Jupitor TV Connector 1 Hat Mounted Video Camera 1 Survival suit & L/P Scrubber 1 Hot water suits c/w boots, gloves, Various Sizes 15 Ultrajewel 601 -reclaim helmet 1 KMB 28B Bandmask 1 Bibs Scott Twin Hose 2 Specifications given in good faith but without guarantee. pg. 5
6 BIBS Scott Single Hose 2 O2 Analysers Analox 2 Bailout Cylinder & Backpac 2 1st Stage Reg & Bailout Whip ( Posieden ) 3 Dive Harness 3 A.R vest 4 System Charging whips 6 O2 Cleaning Bath, Multi Metres, Meggers, Tong Testers. Lot System Plant & Equipment Tool Chest, 1 Regulators for Deck Quads 4 Specifications given in good faith but without guarantee. pg. 6
B-1 Buildings & Service Maintenance
B-1 Buildings & Service Maintenance B-1 Buildings & Service Maintenance SAFETY, HEALTH AND ENVIRONMENTAL POLICY: B-1 DATE OF ISSUE: AUGUST 1994. BUILDINGS AND SERVICES MAINTENANCE 1. Introduction It is
Repairs: who s responsible?
Your responsibilities as a tenant in a sheltered scheme Condensation Condensation Damage Damage caused by you Domestic appliances We will repair domestic appliances if they have been provided by us Keys
Topics of the Presentation
Drill Rig Safety Topics of the Presentation Personnel safety and monitoring PPE Health (Drugs and Alcohol) Drill Rig operation Safe set up procedures Safe operation of machine Safety related accidents
CUBICLE SYSTEMS LTD. CI/SfB 74 X IPS. Pre-plumbed Wall Duct Access Panel System
CUBICLE SYSTEMS LTD CI/SfB 74 X IPS Pre-plumbed Wall Duct Access Panel System ISO 9001:2000 IPS the perfect washroom solution plumbing wall duct panel system and cubicles installed in one operation Cubicle
ANNEX 4 - IG Rate Comparison TECHNICAL COMPARISON OF CONTRACT TERMS T&T BISSO
ANNEX 4 - IG Rate Comparison TECHNICAL COMPARISON OF CONTRACT TERMS - Version 7 June 2010 (1) Category 1 - vessel adrift TOWHIRE SCOPIC rates with 20% uplift, out-of-pocket expenses at cost plus 15% (2)
To: All Shipowners, Ship Managers, Ship Masters and Classification Societies
海 事 處 船 舶 事 務 科 香 港 中 環 統 一 碼 頭 道 38 號 海 港 政 府 大 樓 ---------- 香 港 郵 箱 4155 號 MARINE DEPARTMENT Shipping Division Harbour Building 38 Pier Road, Central, Hong Kong ----------- G.P.O.Box 4155 網 站 Website
POSEIDON ISLA TRAWLERS 1490
POSEIDON ISLA TRAWLERS 1490 GENERAL CHARACTERISTICS AND MAIN MEASURES Loa 14.95 m Lwl 13.40 m Bmax 4.95 m Draught max 1.50 m Depth 2.15 m Full Displacement 30.0 tonnes Certifications : Built to CE certification
Cooling system components, removing and installing
Page 1 of 34 19-1 Cooling system components, removing and installing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate
SANITARY & WASTE WATER PUMPING SYSTEMS. Now you can install kitchen, bathroom, laundry and commercial facilities almost anywhere.
SANITARY & WASTE WATER PUMPING SYSTEMS Now you can install kitchen, bathroom, laundry and commercial facilities almost anywhere. Wallace Pumps solve all those waste disposal problems, big or small, with
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion
Engineered Solutions
Engineered Solutions Long established partnerships bring together the world s leading instrumentation companies within BKW. Our manufacturing facility enables us to quickly adapt standard instruments to
Confined Space Entry Procedure Worksheet
1. Location Exact name and location of space to be entered. Confined Space Entry Procedure Worksheet 2. Hazard Identification & Determination - (circle all that apply) a. Tasks to be performed. Welding/Cutting
WARRANTY BOOKLET. Commercial Water Heaters. Register online at www.rinnai.com.au
WARRANTY BOOKLET Commercial Water Heaters Register online at www.rinnai.com.au Rinnai Commercial Water Heating Products Warranty Warranty Terms The benefits to the consumer given by this warranty are
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS ODEON IN-WALL TANK K-6283K/ K-6284K/ K-6286K Read installation guide in illustration and word file carefully, and install the tank according to instructions in the guide to avoid
tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable
tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable Port side cable (with black cable tie attached) Power cable Preparing for Installation 1 Overall
E. Fowler & Sons Ltd.
Oil storage tank manufacturers EFS 5000 BUNDED WITH SECURITY CABINET EFS 1200 DOMESTIC capacity: 1200 litres dimensions: length 1780mm width 550mm height 1250mm finish: 2 coats bitumen on bottom 2 coats
section 5 machine guarding and lockout
section machine guarding and lockout This section covers ways to physically protect people working in and around machinery. It includes information on: machinery guards lockout systems emergency stop confined
The Yachtmans Choice...
Ref: 1740, Nov 2015 The Yachtmans Choice... A competitive price 10 to 150 hp, engineered in the UK Advanced, compact, quiet reliable engines Easy engine replacement, with our special feet option Amazing
301.7D. Mini Hydraulic Excavator
301.7D Mini Hydraulic Excavator Engine Weights Gross Power (ISO 14396) 17.9 kw 24.3 hp Operating Weight with Canopy 1610 kg 3,550 lb Net Power 13.2 kw 17.7 hp Operating Weight with Cab 1720 kg 3,792 lb
Waste Oil Handling, Spill Containment & Lighting
58 Waste Oil Handling, Spill Containment & Lighting 372000 SAMOA Mobile Waste Oil Drainer & Extractor Drains and/or extracts waste oil from cars and light commercial vehicles Drain bowl capacity of 20
FOGA ApS. Arctic Hunter Multipurpose/support vessel
Arctic Hunter Multipurpose/support vessel General information Name... Arctic Hunter IMO #... 7719832 Call sign... OUWK MMSI #... 331404000 Flag state... Danish Ship Register Home port... Esbjerg Class...
JUBILEE TECHNICAL TRAINING CENTRE TAKORADI POLYTECHNIC 2015 TRAINING PROGRAMMES
JUBILEE TECHNICAL TRAINING CENTRE TAKORADI POLYTECHNIC 2015 TRAINING PROGRAMMES Main Courses Duration: 26 weeks 1. NVQ Level 2 Performing Process Operation in Replicating Environment 2. NVQ Level 2 Performing
ELECTRICAL WIRING (R.H. DRIVE VEHICLES)
C-1 ELECTRICAL WIRING (R.H. DRIVE VEHICLES) CONTENTS GENERAL.......................... 3 WIRING HARNESS CONFIGURATION DIAGRAMS......................... 4 ENGINE COMPARTMENT................ 4 DASH PANEL...........................
Installation Instructions for Alarm Module Kit A043F059
Instruction Sheet 07-2013 Installation Instructions for Alarm Module Kit A043F059 1 Introduction The information contained within is based on information available at the time of going to print. In line
ECHM Recommendations for Safety in multiplace medical hyperbaric chambers
ECHM Recommendations for Safety in multiplace medical hyperbaric chambers Coordination and Correspondence : D. MATHIEU, Service d'urgence Respiratoire, de Réanimation Médicale et de Médecine hyperbare
TRUCK MOUNTED KNUCKLE BOOM HYDRAULIC CRANE PROPOSAL
TRUCK MOUNTED KNUCKLE BOOM HYDRAULIC CRANE PROPOSAL CUSTOMER: SUPPLIER: CONTACT: DATE: E-mail: VALIDITY: 1 month Dear Sir, In the attached file you will find the proposal and specification(s) for the ASK
Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1
Visage Digital Digital diverter TM Installation guide Visage Digital diverter installation instructions Page 1 Visage Digital diverter Visage Digital concealed with adjustable and fixed head Visage Digital
Service Packages & Pricing
Service Packages & Pricing Silver Gold Motorcycle Service Packages Change oil & filter Change oil & filter Fuel system treatment $ 109.95 $ 129.95 Platinum Replace spark plugs Change oil & filter Fuel
Please also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk
1. Description Sanicom is a lifting pump for wastewater used in commercial applications (restaurants, hairdressing salons, the catering industry etc.). The unit operates automatically, has a high performance
TRUCK MOUNTED KNUCKLE BOOM HYDRAULIC CRANE PROPOSAL
TRUCK MOUNTED KNUCKLE BOOM HYDRAULIC CRANE PROPOSAL CUSTOMER : - SUPPLIER : CONTACT PERSON : DATE : E-mail: VALIDITY: Dear In the attached file you will find the Proposal and specification(s) for the ASK
Capital Expenditure. The common definition of capital expenditure is
Capital Expenditure Under standard accounting practices local authorities are required to account for revenue expenditure and capital expenditure differently. Capital expenditure is defined in the Local
Design and manufacture of subsea and topside composite cables and connectors
Overview Design and manufacture of subsea and topside composite cables and connectors Hydro Group. [email protected] www.hydrogroup-asia.com tel: +65 63343566 fax: +65 63343566 1 : 5 Hydro Group
E-gas Instant Gas Water Heaters
The Proven Preferred Choice! E-gas Instant Gas Water Heaters Training & Information Manual: There are important functional and operational differences between the conventional hot water geyser and the
Work Order History Report
Work Order History Report Asset MG304 Asset: MG304, Including Children, Active: True Grader, motor W/O No Description Finished Done 1570 MG304 - Perform Plant Audit and Mobile Plant Mechanical Check List.
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
TRUCK MOUNTED KNUCKLE BOOM HYDRAULIC CRANE PROPOSAL
TRUCK MOUNTED KNUCKLE BOOM HYDRAULIC CRANE PROPOSAL CUSTOMER : - SUPPLIER: CONTACT PERSON: DATE: E-mail: VALIDITY: Dear In the attached file you will find the Proposal and specification(s) for the ASK
Competency Framework for Marine Engineer Class 6. Competency Framework for Marine Engineer Class 6
Table of Contents (MEC 6)... 1 Function: Operate Vessel Machinery and Systems... 1 Diesel engines.... 1 Operational procedures.... 3 Operate and monitor a vessel s engines and auxiliary equipment.... 4
Gazeley. Where You and Your Horses Safety Comes First. Coachbuilders Ltd. Designed and Manufactured in Newmarket, Suffolk, Great Britain
Gazeley Coachbuilders Ltd HORSEBOX MANUFACTURER Designed and Manufactured in Newmarket, Suffolk, Great Britain Where You and Your Horses Safety Comes First Gazeley Coachbuilders Ltd is a total family business.
PBX Series Quick Fit Connector Bimetallic Steam Traps
6262100/6 IM-P626-01 ST Issue 6 PBX Series Quick Fit Connector Bimetallic Steam Traps Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning
Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)
47 Brakes - Hydraulic Components (Page GR-47) FS III front brake calipers, servicing Front brake caliper piston, removing and installing FN 3 front brake calipers, servicing Front caliper piston, removing
understanding medium frequency induction melting furnace and its components
understanding medium frequency induction melting furnace and its components 9 Spruce Street, Jersey City, NJ 07306 USA [email protected] INDUCTION MELTING FURNACE AND ITS COMPONENTS The purpose
Safety Flash. IMCA Safety Flash 18/13 December 2013. 1 Fatality During Lifting Operations
AB Safety Flash IMCA Safety Flash 18/13 December 2013 These flashes summarise key safety matters and incidents, allowing wider dissemination of lessons learnt from them. The information below has been
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook Trainee:... Training Provider:... Year:... Trainee Contact no:... Competency Based Skill Training Logbook Introduction
RACE TRANSPORTER TRAILERS RACE PROFESSIONAL
» Connected to you RACE TRANSPORTER TRAILERS RACE PROFESSIONAL UNITED KINGDOM CONTENT 04 06 10 14 18 20 22 RACE TRANSPORTER Overview. RACE TRANSPORTER 4 Up to mid sized road cars and larger race cars.
API Marine. BMS Presentation. Ballast Measurement Systems
API Marine BMS Presentation Ballast Measurement Systems BMS4 Typical Configuration BMS4 Typical Configuration BMS4 Extended Configuration BMS4 System (24 tanks) Air regulator Terminal block Drain/Air Filter
The Engine Department
The Engine Department The Engine Department of a cruise ship is part of the Marine Operations Division. Although the Engine Department team is primarily responsible for the safe and smooth operation of
Integrated Custom Systems
Integrated Custom Systems Compact panels Standard Manifolds & Assemblies Electronic pressure control Custom manifolds & Assemblies Automated test benches S t r e a m l i n e y o u r p r o c e s s Complete
TANKLESS WATER HEATER INSTALLATION DIAGRAMS
TANKLESS WATER HEATER INSTALLATION DIAGRAMS Installation Diagrams Tankless Installation / Optional Return Small 10-15 Gallon Point-of-Use Water Single and Optional Return : One single, small capacity water
Troubleshooting Guide for Jacks Down LED Lights
Troubleshooting Guide for Jacks Down LED Lights Equalizer Systems Auto-Level systems manufactured after 2005 feature a pressure switch system that monitors the retracted state of leveling jacks and any
CO 2. fire extinguishing systems
fire extinguishing systems Extinguishing technique is a colourless, odourless and electrical non-conductive gas. In systems the is mixed with a special identifiable odour. The extinguishing effect of is
Lebanon Fire Department Lebanon Engine 512 Check Sheet
Page 1 of 8 Initials Engine Oil Transmission Fluid Windshield washer fluid Radiator level Power Steering Fluid Mileage (All digits) Brakes/Air Tanks Fuel Level Windshield Wipers Brake Lights Interior Lights
Fire Protection Program Of Chashma Nuclear Power Generating Station Pakistan Atomic Energy Commission 5/28/2015 1
Fire Protection Program Of Chashma Nuclear Power Generating Station Pakistan Atomic Energy Commission 5/28/2015 1 Nuclear Power in Pakistan Nuclear Power Plants Capacity (MWe) Year of Commissioning In
Appendix 3H A/V and Video Conferencing Standard
Appendix 3H A/V and Standard 1. Introduction The Authority uses meeting and conference rooms for a variety of purposes. All new construction will have a mix of each type of room type as identified below.
UNDERWATER ENGINEERING SERVICES. Visit Us Online At www.uesltd.net Part of the ATR Group
UNDERWATER ENGINEERING SERVICES Visit Us Online At www.uesltd.net Part of the ATR Group PART OF THE ATR GROUP Global Equipment Specialists THE ATR DIVISIONS At ATR, we believe we re the logical choice
Rail 001 112 2 Canvas, folding top 001 101 3 Rear panel 001 102 4 Stip in window, left 001 106 dto. right 001 107
U 411 1 Rear view mirror, round, metall 13cm Ø 002 045 2 Raised airintake 002 060 3 Side panelling, front, left 002 030 Side panelling, front, right 002 031 4 Panelling left 002 051 dto. right 002 052
Air Vantage 500 Kubota
Illustration of Sub Assemblies Illustration of Sub Assemblies Illustration of Sub Assemblies Illustration of Sub Assemblies P-625 P-625 RETURN TO MAIN INDEX PARTS LIST FOR Air Vantage 500 Kubota P-625-A
Turnkey Projects, Conversions, Restorations & Property Management. Marsalforn - Gozo APARTMENT FINISHING EXCLUSIVE PACKAGE
Turnkey Projects, Conversions, Restorations & Property Management Marsalforn - Gozo APARTMENT FINISHING EXCLUSIVE PACKAGE Reg. Office: Karlu Galea Street, Victoria, Gozo Malta. T. 2155 6600 M. 9943 4391
Property Services. Maintainable Assets Description Hierarchy. Revision 4.3a
Property Services Maintainable Assets Description Hierarchy Revision 4.3a 26 August 2011 Schedule of amendments to description hierarchy: Date Item Old New 12/08/08 Schedule of amendments nil Added 12/08/08
COMITÉ EUROPÉEN DES ASSURANCES
COMITÉ EUROPÉEN DES ASSURANCES SECRETARIAT GENERAL 3bis, rue de la Chaussée d'antin F 75009 Paris Tél. : +33 1 44 83 11 73 Fax : +33 1 44 83 11 85 Web : cea.assur.org DELEGATION A BRUXELLES Square de Meeûs,
EXPORT w w w. k r a n m a n. c o m
EXPORT Kranman T1700 4WD series for ATV. Hydraulic unit KS-780 Facts: standard equipped T1700 Trailer T1700 4WD Total width 1.340 mm 4WD drive Hydraulic Total length 3000-3900 mm Pivoting stays 4 Load
Flood Rescue Emergency Services First Responders Coast Guard Police
RESCUE RESCUE RESCUE Flood Rescue Emergency Services First Responders Coast Guard Police Sealegs amphibious marine craft give rescue and patrol organizations unique multi-role capabilities which cannot
DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information
Safety Safety Is Your Responsibility DANGER To avoid personal injury or death, carefully read and understand all instructions pertaining to the Anthony Liftgates product. Do not attempt to install, operate,
creating progress for the future
CREATING PROGRESS OFFSHORE creating progress for the future CREATING PROGRESS SCANAOFFSHORE Scana Offshore group of companies will be present at the OTD in Stavanger, October 23-24 2013. The companies
Table of Contents. Division 2 Site Work Site Preparation Site Demolition Tree Protection Excavation, Trenching, and Backfilling for Utilities
Division 1 Requirements Design and Construction Quality Campus Master Plans Texas Tech University System Operating and Building Maintenance Project Administration Historically Underutilized Business (HUB)
Asking Price: N/A Final Price: N/A OROPS BUCKET AUXILIARY HYDRAULICS GENERAL APPEARANCE. Good. Good
Page 1 of 6 SPECIFICATIONS 2005 CATERPILLAR 247B Customer Owned Certified MULTI TERRAIN LOADERS Inspection Number: 1117842 Serial #: MTL01706 Date Created: 09/23/2013 02:53:31 PM CDT Engine Serial #: N/A
S/Y SEEWIND VAN DER STADT SEAL 36
This is the perfect boat for someone who wants to travel. Seewind is incredibly well set up for a boat of this size. And she is clean and dry and very sturdy. She can sleep up to 7 people and has a watermaker,
Dacia Sandero and Sandero Stepway Accessories Range
Dacia Sandero and Sandero Stepway Accessories Range All you need for long-term protection and maximum comfort. Simply a clever choice! CONTENTS DESIGN Exterior 4 Interior 4 Wheels 4 TRANSPORT Towing and
SITE ACCOMODATION BUILDINGS, ABLUTION BLOCKS, CONTAINERS AND PORTABLE COMPLEXES
SITE ACCOMODATION BUILDINGS, ABLUTION BLOCKS, CONTAINERS AND PORTABLE COMPLEXES 13 40 40 Site Accomodation Overview Our Knowledge Your Choice More than just a tagline. The Onsite Rental Group is made up
SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R8216470-01EN - Edition 01-26/10/2009
Instantaneous Gas Water Heaters Storage Gas Water Heaters SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model R8216470-01EN - Edition 01-26/10/2009 Boilers CUENOD Renewable 3121488 12 EAA1...... 3124527 25
Engineers Edge, LLC PDH & Professional Training
510 N. Crosslane Rd. Monroe, Georgia 30656 (770) 266-6915 fax (678) 643-1758 Engineers Edge, LLC PDH & Professional Training Copyright, All Rights Reserved Engineers Edge, LLC An Introduction to Communication
Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier
Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier A. Requirement This document is to be used to specify the physical and operational
2010 APPLICATION REFERENCE GUIDE
2010 APPLICATION REFERENCE GUIDE INDEX QUALITY POLICY 2 ERGO ASSIST STANDARD 4-13 CUSTOM 14-18 END EFFECTORS 19-24 LIFT ASSIST 25-41 FIXTURED TOOLS 42-53 FIXTURES 54-63 ASSEMBLY TABLES 64-72 CARTS/ DUNNAGE
Experience Our Innovation
Experience Our Innovation Rinnai Holdings (Pacific) Pte Ltd 47 Tannery Lane #05-01/02 Elite Industrial Buiding II Singapore 347794 T. +65 6748 9011 F. +65 6745 9240 E. [email protected] www.rinnai.sg
INSTALLATION INSTRUCTIONS
Rear Vision System Tailgate Handle Camera Mirror Display 2004-2014 Ford F-150 and 2008-2015 Ford Super Duty (Kit part numbers 9002-9521) Kit Contents: Mirror Tailgate Handle with camera and harness Interior
THE BASICS DOOR ENTRY AND ACCESS CONTROL SYSTEMS. Intercoms R Us Ltd 2013 (c)
THE BASICS DOOR ENTRY AND ACCESS CONTROL SYSTEMS SYSTEM PLANNING Intercoms R Us Ltd 2013 (c) Forward thinking and planning is essential and will save a lot of hassle in the long run and will ensure that
2015 Malpelo Expedition 7 Diving Days
2015 Malpelo Expedition 7 Diving Days November 29 to December 09 Aboard MV YEMAYA - large schools of hammerheads; hammerhead sharks can be seen all year round, but scientists have observed that the schools
Nominal Life Expectancy for Building Components
Nominal Life Expectancy for Building Components Building System Page A. HVAC 2 B. Elevator/Escalator 6 C. Plumbing 7 D. Roofing 8 E. Electrical 10 F. Fire/Life/Safety/Security System 11 G. Interior Finishes
Fire Protection Systems, Appliances and Compressed Gas Cylinders Periodic Maintenance, Inspection and Testing
Fire Protection Systems, Appliances and Compressed Gas Cylinders Periodic Maintenance, Inspection and Testing Notice to Shipowners, Ship Operators, Managers, Masters, Owners Representatives and Recognised
AIR COMPRESSORS come with an inflating pistol and gauge for tyre inflation as well as additional accessories for use around the home.
Today MICHELIN is developing new consumer products which not only support motorists needs but go further to provide assistance with general care and maintenance needs in and around the home. The MICHELIN
INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX
Fan Coil Replacement Coil Kit EBX & EBXX These instructions must be read and understood completely before attempting installation. These instructions covers the installation of replacement coil kit into
Federal Wage System Job Grading Standard for Powered Support Systems Mechanic, 5378. Table of Contents
Federal Wage System Job Grading Standard for Powered Support Systems Mechanic, 5378 Table of Contents WORK COVERED... 2 WORK NOT COVERED...2 GRADES... 2 TITLES... 3 HELPER AND INTERMEDIATE JOBS... 3 NOTE
DESIGN STANDARDS SECTION 23 60 00
PART 1 - GENERAL 1.01 Work included: A. Piping, tubing and fittings. B. Piping specialties. C. Special duty valves. D. Refrigerants. E. Chillers. F. Refrigerant monitors. 1.02 General requirements: A.
Total Solutions Providers for Fire & Security Systems
Total Solutions Providers for Fire & Security Systems Tyco Fire & Security UAE is a joint venture between Suwaidi Engineering Group and Tyco Fire & Integrated Solutions. Established in 1994, we now employ
Oxygen & Nitrogen. Oxygen & Nitrogen Service Catalog. Parts & Complete Systems
Oxygen & Nitrogen Oxygen & Nitrogen Service Catalog Parts & Complete Systems Why buy our carts? Whether you need a complete system or just a few items, our knowledgeable technical staff can custom configure
FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST
FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST Date of Inspection: Conducted by: Location: Reviewed by: Date of Review: Comments or additional corrective action taken as a result
FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid
Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars Presented By: Greg Pelster & Robert Schmid FFI Ferrie, Franzmann Industries LOW VOLTAGE SWITCHGEAR & LOW VOLTAGE
How to report a repair
How to report a repair for repairs to your home? We are committed to making sure your home is in a good state of repair. To meet our legal responsibilities we will: Keep the exterior (eg roof, walls, doors,
Rules for Classification and Construction Additional Rules and Guidelines 3 Machinery Installations
VI Rules for Classification and Construction Additional Rules and Guidelines 3 Machinery Installations 5 Guidelines for Design, Equipment and Testing of Gas Welding Installations on Seagoing Ships Edition
INTRODUCTION INDUSTRIAL INSTALLATIONS AND ERECTIONS QUALITY THAT EXCELS
QUALITY THAT EXCELS INTRODUCTION Established in July 1996, aiming at attending market needs, Munhoz positively has taken charge of supplying high standard solutions, in the projects, civil constructions,
REGISTRATION EXAMINATION, JUNE 2009 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours
Affix label with Candidate Code Number here. If no label, enter candidate Number if known No. 99 REGISTRATION EXAMINATION, JUNE 009 PLUMBING INSTRUCTIONS QUESTION AND ANSWER BOOKLET Time allowed THREE
Method Statements. Debenham House, 8 Addison Road, London, W1J 8DJ Debenham House 8 Addison Road Holland Park W14 8DJ.
Method Statements Debenham House, 8 Addison Road, London, W1J 8DJ Debenham House 8 Addison Road Holland Park W14 8DJ Method Statements Method Statement - Plumbing Central Heating - Gas & domestic Pipework
Guidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters
Guidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters When water is heated, it naturally expands and allowance has to be made for this. Vented water heaters usually
REGISTRATION OF INTEREST
A B C Adhesives and Sealants Advertising Air Cargo Transport Air Conditioners Air Conditioning Installation or Maintenance or Repair Services Air Filters Ambulance Services Arborist Services Architectural
ILLUSTRATED PARTS LIST
TW400 WITH 390cc HONDA ENGINE 390cc 2 WHEEL DRIVE UTILITY VEHICLE ILLUSTRATED S LIST 390cc 2WD B O D Y D I A G R A M 390cc 2WD F R A M E D I A G R A M 390cc 2WD D R I V E T R A I N D I A G R A M DESCRIPTION
Facility Support Services
Facility Support Services The Precision Group has a breadth of experience delivering innovative, first class facility support service solutions to clients across the public and private sectors. Our expert