Installation & Maintenance Manual of Hydrocyclone. Hydrocyclones is also called cyclone separator.hydrocyclones include
|
|
- Numb Wong
- 8 years ago
- Views:
Transcription
1 More Mud Solids Control Equipment, You can Visit: Installation & Maintenance Manual of Hydrocyclone Hydrocyclones is also called cyclone separator.hydrocyclones include hydrocyclone desander (10 in. cone) and hydrocyclone desilter (4 in. cone),which used to separate sand and silt from the drilling fluid. A hydrocyclone has two exits on the axis: the smaller on the bottom (underflow or reject) and larger at the top (overflow or accept). The underflow is generally the denser or thicker fraction, while the overflow is the lighter or more fluid fraction. Centrifugal pump is used to pump the drilling fluids from mud tank into the set of hydrocyclones. KOSUN desander has Flexible options for 1,2 or 3 hydrocyclone desander for different capacities and desilter has flexible options for 8 or 10,12,16 hydrocyclone for different capacities. Desander is installed after shale shaker and degasser but before desilter. Desander removes those abrassive solids from the drilling mud which cannot be removed by shale shaker. As a key part of drilling fluids solids control equipment, hydrocyclones in different specifications work against different diameters and for different cleannesses. Besides, separation capacity is closely related with cyclone diameter since larger diameter is aimed at larger particles while smaller one contends with smaller particles.
2 More Mud Solids Control Equipment, You can Visit: Installation & Maintenance of Hydrocyclone: 1. Desander ought to be installed on a well-prepared, flat foundation or merely on the ground. Then three expansion bolts are adequate to keep the base stable on the foundation built with concrete, which has a round or square surface and is 150mm high. 2. Take notice of the pipelines and flow directions in the installation. 3. Surface configuration of mud tank ought to include some space for operators. Though no maintenance is necessary for desander when it has no mobile parts, it is important to maintain a stable load at the inlet and proper force towards the drain valve, and to keep it from human damage.
COMMITMENT TO EXCELLENCE
PERFORMANCE DRIVEN OPERATIONS IN TEXAS AND OKLAHOMA COMMITMENT TO EXCELLENCE Basin Drilling, LP 1121 ESE Loop 323 Suite 218 Tyler, Texas 75701 (903) 561-8211 (903) 561-5844 fax www.basindrilling.com About
More informationUNDER DRAINAGE AND FILTER DESIGN
UNDER DRAINAGE AND FILTER DESIGN Tailings and HLP Workshop 28 April to 1 May 2010 INTRODUCTION The internal drainage is of crucial importance to the reliability and safety of a tailings dam throughout
More informationDomino VGS. Domino. Vertical Gravity Separator VGS. Oil Out. Clean Water Outlet. Oily Water In. Sludge Outlet. Everything Water PTY LTD
Vertical Gravity Separator Oil Out Clean Water Outlet Oily Water In Sludge Outlet Pg 1 Introduction Product Overview The is an oil/water separator developed to effectively remove free oil, grease and suspended
More informationESP FLOWSHEET SIMULATION APPLICATION BRIEF Downhole Oil/Water Separation
ESP FLOWSHEET SIMULATION APPLICATION BRIEF Downhole Oil/Water Separation The largest volume waste stream associated with oil and gas production is produced water. Water to gas ratios of 10 to 1 are common
More informationCase Study: Treatment of alluvial sand, treatment of washing water and sludge.
Case Study: Treatment of alluvial sand, treatment of washing water and sludge. Client: FAMY & Cie SARL Site of BELLEGARDE Presentation of the project: The company Famy operates in the department of Ain,
More informationThe Importance of Oil-based Mud in Shale Gas Exploration. Many unsolved problems in shale gas exploration are mostly attributed to
High capacity drilling mud solids control equipment manufacturer- http://www.china-kosun.com/ The Importance of Oil-based Mud in Shale Gas Exploration Many unsolved problems in shale gas exploration are
More informationAUTOMATIC TANK CLEANING (ATC) LITE On-the-fly automatic tank cleaning and recycling technology
AUTOMATIC TANK CLEANING (ATC) LITE On-the-fly automatic tank cleaning and recycling technology ATC Lite: Permanent or mobile option for safe and continuous onshore, offshore tank cleaning applications
More informationHow To Maintain A 50 Ton Tankers
On behalf of our client Pacifico Forages S.A. France, we offer for immediate sale the following Drilling Rig and Associated Equipment. The Equipment may be purchased as a whole or in individual packages
More informationC. starting positive displacement pumps with the discharge valve closed.
KNOWLEDGE: K1.04 [3.4/3.6] P78 The possibility of water hammer in a liquid system is minimized by... A. maintaining temperature above the saturation temperature. B. starting centrifugal pumps with the
More informationSAMPLE TEST QUESTIONS STEAMFITTER/PIPEFITTER - ITA WEBSITE
1 Which tool is used to correct internal hi-low when preparing a 4-in. steel pipe for welding? A. 4-in. grinder with cutting disc. B. Mini-grinder with flapper disc. C. Pencil grinder with cone stone.
More informationSpill Containment. IBC Bunds
IBC Bunds 1 x IBC Bund, Spill Pallet or Sump Pallet 2 1 x IBC Bund, Spill Pallet or Sump Pallet with dispensing facility 3 2 x IBC Bund, Spill Pallet or Sump Pallet 4 2 x IBC Bund, Spill Pallet or Sump
More informationVOYAGER 570G. 744A Sprayer Control
VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER
More informationGuidelines for Precast Concrete Grease Interceptors
Guidelines for Precast Concrete Grease Interceptors Purpose Provide an overview of the basic design principals that govern why gravity grease interceptors work Provide a forum for discussion of common
More informationMaintenance of drilling fluids jet mud mixer. Jet mud mixer is used to make and mix drilling fluid to change the
High capacity drilling mud solids control equipment manufacturer- http://www.china-kosun.com/ Maintenance of drilling fluids jet mud mixer Jet mud mixer is used to make and mix drilling fluid to change
More informationfor Sediment Removal desired levels. The filtered water then can be chemically treated to ensure its safety. Municipal water Preliminary settling
Treating Water for Sediment Removal J.R. Miner Lakes, ponds, and streams are important sources of water for many farms, rural camps, and households as well as for many municipalities in Oregon. Even under
More informationSafety In The Workplace
GEO Drilling Fluids, Inc.! P.O. Box 1478! Bakersfield, CA 93302 Telephone (661) 325-5919! FAX (661) 325-5648!1-800-GETSGEO! geodf@lightspeed.net Drilling Fluids, Inc. TECHNICAL SERVICES NEWS LETTER Volume
More informationUVDB empowered by Achilles
UVDB empowered by Achilles DISAB Centurion: High Performance Wet/Dry Materials Handling Unit DISAB Centurion: High performance vacuum tanker that will vacuum dry or wet material The DISAB can vacuum material
More informationPLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:
PLATE HEAT EXCHANGER Installation Manual Customer Name: Serial number: Purchase order number: Project: Table of Contents ----------------------------------------------------------------- Page: 2 3 Name
More informationHYDRAULICS. H91.8D/C - Computerized Open Surface Tilting Flow Channel - 10, 12.5, 15 and 20 m long
HYDRAULICS H91.8D/C - Computerized Open Surface Tilting Flow Channel - 10, 12.5, 15 and 20 m long 1. General The series of channels H91.8D has been designed by Didacta Italia to study the hydrodynamic
More informationSEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT
SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT The following are minimum requirements for installation of conventional trench sewage disposal systems in St. Mary s County,
More informationINSTALLATION, OPERATION & MAINTENANCE MANUAL
INSTALLATION, OPERATION & MAINTENANCE MANUAL Flanged Disk Check Valve with Strainer Ref. GENEBRE: 2450 2451 2452 1 INSTRUCTIONS FOR INSTALLATION, OPERATION & MAINTENANCE MANUAL 1. Spare parts... 3 1.1
More informationCHAPTER 11 STORM DRAINAGE
CHAPTER STORM DRAINAGE SECTION PC 0 GENERAL 0. Scope. The provisions of this chapter shall govern the materials, design, construction and installation of storm drainage. Storm water discharge shall be
More informationBLADDER SURGE CONTROL SYSTEM
PART I GENERAL 1.01 Description BLADDER SURGE CONTROL SYSTEM This specification describes the requirements for a Bladder Surge Control System. The purpose of the system is to minimize transient pressures
More informationSYNERGISTIC APPLICATION OF ADVANCED PRIMARY AND SECONDARY WASTEWATER TREATMENT SYSTEMS
SYNERGISTIC APPLICATION OF ADVANCED PRIMARY AND SECONDARY WASTEWATER TREATMENT SYSTEMS Published in Water and Waste Digest membrane issue, November 2008 Miroslav Colic; Chief Scientist, Clean Water Technology
More informationThe University of Toledo Soil Mechanics Laboratory
The University of Toledo Soil Mechanics Laboratory Permeability Testing - 1 Constant and Falling Head Tests Introduction In 1856 the French engineer Henri D arcy demonstrated by experiment that it is possible
More informationWeek of Mar. 22, 2004/US$10.00. International Petroleum News and Technology / www.ogjonline.com. Ethylene Report
Week of Mar. 22, 2004/US$10.00 International Petroleum News and Technology / www.ogjonline.com Ethylene Report MTBE issues broader than liability protection debate Seismic weight drop quest leads to improved
More informationRMF TANDEM 900 OFF-LINE FILTER SYSTEMS
RMF TANDEM 900 OFF-LINE FILTER SYSTEMS RMF Tandem 900 Off-line filter Systems can be applied to every imaginable industrial application where hydraulic or lubrication systems are present. An integrated
More informationTampa Bay Seawater Desalination Plant
Tampa Bay Seawater Desalination Plant Project History How The Plant Works Desal Fun Facts 2575 Enterprise Road, Clearwater, FL 33763-1102 Phone: 727.796.2355 / Fax: 727.791.2388 www.tampabaywater.org Tampa
More informationDrill Cutting, Mud and Slurry Handling Oil & Gas Industry
Drill Cutting, Mud and Slurry Handling Oil & Gas Industry Natural gas production platform Åsgard B (Photo Øyvind Hagen, Statoil Petroleum ASA) Drill Cuttings Handling Storage and Pumping on Rigs Since
More informationMechanical Seal Piping Plans
Mechanical Seal Piping Plans Single Seals plans 01, 02, 03, 11, 13, 14, 21, 23, 31, 32, 41 Dual Seals plans 52, 53A, 53B, 53C, 54, 55 Quench Seals plans 62, 65A, 65B, 66A, 66B Gas Seals plans 72, 74, 75,
More informationFiberstars Mini Lighted Laminar Flow Fountains
Fiberstars Mini Lighted Laminar Flow Fountains SAVE THESE DIRECTIONS! These directions are provided to ensure the proper installation and operation of Fiberstars Mini Lighted Laminar Flow Fountain. The
More informationThe Worcester Greenstar System Filter. An innovative solution for reducing system contaminants
The Worcester Greenstar System Filter An innovative solution for reducing system contaminants Protect your customer s heating system with the Greenstar System Filter Modern condensing boilers are precision
More informationTECHNICAL NOTES 6 MANUFACTURED-MEDIA GRAVITY SEPARATORS
TECHNICAL NOTES 6 MANUFACTURED-MEDIA GRAVITY SEPARATORS R P King 2000 GRAVITY SEPARATION Differences in the density of individual particles can be exploited to effect a separation and concentrate the desired
More informationSUMP PUMP. City of Ann Arbor & C O L L E C T I O N S Y S T E M G L O S S A R Y
Foundation A foundation is the bottom part of a building. It s the element that anchors the building to the ground and transmits the building s gravity load directly to the earth. Water damage weakens
More informationSEPTIC TANKS FOR THE COLLECTION & SETTLEMENT OF DOMESTIC SEWAGE
SEPTIC TANKS FOR THE COLLECTION & SETTLEMENT OF DOMESTIC SEWAGE Let us help! Free professional site visit with friendly support and advice. helpingyou@klargester.com to make the right decision or call
More informationSPECIFIC GRAVITY OF COARSE AGGREGATE AASHTO T 85
SPECIFIC GRAVITY OF COARSE AGGREGATE AASHTO T 85 GLOSSARY Absorption: The increase in weight due to water contained in the pores of the material. Bulk Specific Gravity (also known as Bulk Dry Specific
More informationWelcome: What is U Drain? Drain Materials. Flow
Welcome: Thank you for looking into the U Drain floor drain system. This paper will explore the functional features of the U Drain and why it is superior to other grated systems in the marketplace. We
More informationPRIVATE WELL SEPARATION
PRIVATE WELL SEPARATION This is an explanation to explain what you have to do with your well, and/or the other sources of water that you may have, in order to receive public water. The term well includes
More information1 DESCRIPTION OF THE APPLIANCE
1 DESCRIPTION OF THE APPLIANCE 1.1 INTRODUCTION The cast iron SF boilers are a valid solution for the present energetic problems, since they can run with solid fuels: wood and coal. These series of boilers
More informationLEAK DETECTION IN UNDERGROUND PIPELINES OF MUNICIPAL WATER DISTRIBUTION
4th DAAAM International Conference on Advanced Technologies for Developing Countries September 21-24, 2005 Slavonski Brod, Croatia LEAK DETECTION IN UNDERGROUND PIPELINES OF MUNICIPAL WATER DISTRIBUTION
More informationPractice Problems on Pumps. Answer(s): Q 2 = 1850 gpm H 2 = 41.7 ft W = 24.1 hp. C. Wassgren, Purdue University Page 1 of 16 Last Updated: 2010 Oct 29
_02 A centrifugal with a 12 in. diameter impeller requires a power input of 60 hp when the flowrate is 3200 gpm against a 60 ft head. The impeller is changed to one with a 10 in. diameter. Determine the
More informationHow To Launch A Rocket From A Formica
Building the Basic Bottle Rocket Launch Pad Materials: -Formica double-sink countertop cutout. This can be easily and cheaply obtained from a local company that manufactures and/or installs countertops.
More informationHydro International First Defense OK 110 Scour and Removal Efficiency Confirmation Tests November 9-10 2010
Hydro International First Defense OK 110 Scour and Removal Efficiency Confirmation Tests November 9-10 2010 Reported by James Houle UNH Stormwater Center On November 9-10, 2010, I witnessed scour and removal
More informationA HOMEOWNERS GUIDE ON-SITE SEWAGE MANAGEMENT SYSTEMS
GEORGIA DEPARTMENT OF HUMAN RESOURCES ENVIRONMENTAL HEALTH SECTION A HOMEOWNERS GUIDE TO ON-SITE SEWAGE MANAGEMENT SYSTEMS March 12, 2002 WHAT IS AN ON-SITE SEWAGE MANAGEMENT SYSTEM An on-site sewage management
More informationUnderstanding and Living With Your Septic System
Chapter 9 Understanding and Living With Your Septic System Rural versus urban sewage treatment One of the big difference between rural and city life is how sewage is dealt with. Cities usually have community
More informationDrilling rigs and technologies
3.1 Drilling rigs and technologies 3.1.1 Introduction The term drilling indicates the whole complex of operations necessary to construct wells of circular section applying excavation techniques not requiring
More informationA copy of Worksheet 1 at the appropriate level for each pupil. Ask pupils to answer the question 'What is sewerage?'
Waste Water Treatment 1. Fascinating Facts Aim: To introduce pupils to key facts about waste water Materials: A copy of Worksheet 1 at the appropriate level for each pupil String Method: Ask pupils to
More informationSPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN
SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN XXXX FARM (CITY OR COUNTY), MICHIGAN CONTACT (NAME), OWNER CERTIFICATION: I hereby certify that I have examined the facility, and being familiar with the
More informationVXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6
- B 1 Product Detail Engineering Data... B2 Structural Support... B6 Engineering Specifications... B9 - B 2 Engineering Data REMARK: Do not use for construction. Refer to factory certified dimensions &
More information50 Tannery Road, Unit 3 Branchburg, NJ 08822 1-800-407-3726 www.drain-net.com
50 Tannery Road, Unit 3 Branchburg, NJ 08822 1-800-407-3726 www.drain-net.com Dear Sir/Madam: VAC S was founded in response to a real problem existing in healthcare facility management today. OSHA s standards
More informationA Guide to Trouble-Free Cooling Towers
A Guide to Trouble-Free Cooling Towers A basic understanding of cooling tower operation and maintenance will help keep a cooling water system running in top condition, year after year By David M. Suptic
More informationIn-Line Air Separators
Air Elimination & Control In-Line Air Separators The AC models of air separators deliver all the quality and performance you expect from Taco products. They are built to last with shell, heads and ANSI
More informationIntroduction: Overview of Soil Mechanics
Introduction: Overview of Soil Mechanics 53:030 Soil Mechanics Notes; C.C. Swan, University of Iowa A. What is "soil"? 1) Not "dirt"! 2) Soil is unconsolidated earthen material comprised of discrete mineral
More informationENGINEERING REPORT FOR PAIES WATER SUPPLY SYSTEM KlTTl MUNICIPALITY, SECTION I, POHNPEI FEDERATED STATES OF MICRONESIA
ENGINEERING REPORT FOR PAIES WATER SUPPLY SYSTEM KlTTl MUNICIPALITY, SECTION I, POHNPEI FEDERATED STATES OF MICRONESIA Ulla Mogensen SOPAC Secretariat May 1996 SOPAC Technical Report 230 Prepared for the
More informationknk5 wmoep5 vtmpq NUNAVUT WATER BOARD NUNAVUT IMALIRIYIN
P.O. BOX 119 GJOA HAVEN, NU X0E 1J0 TEL: (867) 360-6338 FAX: (867) 360-6369 KATIMAYINGI knk5 wmoep5 vtmpq NUNAVUT WATER BOARD NUNAVUT IMALIRIYIN Application for: (check one) WATER LICENCE APPLICATION FORM
More informationRIG AND EQUIPMENT INSURANCE
Tuesday, March 5, 2013 Houston, TX 4:15 5:30 p.m. RIG AND EQUIPMENT INSURANCE Presented by Russel Howes Vice President, Account Executive (Upstream Energy) Willis Global Energy Jason Homrighaus Senior
More informationCERTIFYING DRAINLAYER
No. 9198 REGISTRATION EXAMINATION, NOVEMBER 2013 CERTIFYING DRAINLAYER ANSWER SCHEDULE Plumbers, Gasfitters and Drainlayers Board, 2013. All rights reserved. No part of this publication may be reproduced
More informationINSTRUCTIONS: LocknCharge Laptop Carts
INSTRUCTIONS: LocknCharge Laptop Carts www.lockncharge.com Extra Tools required: Hammer, Philips head screwdriver, medium adjustable spanner. (Allen key supplied) (Panel colours for illustration purposes
More informationBLASTING SYSTEMS. Turbine blasting systems. Air blasting systems. Automatic Painting plants
BLASTING SYSTEMS Turbine blasting systems Air blasting systems Automatic Painting plants 1, Dust Collector 2, Cyclone Separator 3, Sand (shot) Storage Hopper 4, Bucket elevator 5, Primary separator 6,
More informationOnsite Wastewater Concepts, Materials, Regulations & The Application Process Part I
Onsite Wastewater Concepts, Materials, Regulations & The Application Process Part I B Onsite Sewage System Materials Instructors: Bart Harriss, RS, Environmental Manager Florida Department of Health Division
More informationFats, Oil and Grease. Best Management Practices Manual. Information, Pollution Prevention, and Compliance Information For Food Service Facilities
Fats, Oil and Grease Best Management Practices Manual Information, Pollution Prevention, and Compliance Information For Food Service Facilities Pinellas County Utilities Water Quality Management Division
More informationGoliat Produced Water Management
Goliat Produced Water Management Hans Tore Nordbø, Process Engineer, Eni Norge AS Tekna Produced Water Management, 21.01.10-22.01.10, Clarion Hotel Stavanger www.eninorge.no PL229 Goliat location, ownership
More informationStorm Drain Inlet Protection - IP
Storm Drain Inlet Protection - IP DEFINITION A temporary protective device formed around a storm drain drop inlet to trap sediment. PURPOSE To prevent sediment from entering storm drainage systems, prior
More informationStorm Drain Inlet Protection for Construction Sites (1060)
Storm Drain Inlet Protection for Construction Sites (1060) Wisconsin Department of Natural Resources Conservation Practice Standard I. Definition A temporary device installed in or around a storm drain
More informationNational Precast Concrete Association
National Precast Concrete Association NOTES 1. This manual does not claim or imply that it addresses any safety-related issues associated with its use. Operation and maintenance of precast concrete grease
More informationSIEM WIS AS. Siem WIS. UTC June 2008 By Jan Atle Andresen
Siem WIS UTC June 2008 By Jan Atle Andresen Agenda Background Challenges- Technology- Solutions Siem WIS background Well Intervention Solutions AS (Siem WIS), was established in February 2005 and is located
More informationLABORATORY DETERMINATION OF CALIFORNIA BEARING RATIO
LABORATORY DETERMINATION OF CALIFORNIA BEARING RATIO STANDARD IS: 2720 (Part 16) 1979. DEFINITION California bearing ratio is the ratio of force per unit area required to penetrate in to a soil mass with
More informationSIEVE ANALYSIS OF FINE AND COARSE AGGREGATES
Test Procedure for SIEVE ANALYSIS OF FINE AND COARSE AGGREGATES TxDOT Designation: Tex-200-F Effective Date: January 2016 1. SCOPE 1.1 Use this test method to determine the particle size distribution of
More informationTHE PSEUDO SINGLE ROW RADIATOR DESIGN
International Journal of Mechanical Engineering and Technology (IJMET) Volume 7, Issue 1, Jan-Feb 2016, pp. 146-153, Article ID: IJMET_07_01_015 Available online at http://www.iaeme.com/ijmet/issues.asp?jtype=ijmet&vtype=7&itype=1
More informationCSD WATER REMOVAL FILTERS FOR DIESEL
CSD CSD WATER REMOVAL FILTERS FOR DIESEL Remove water to extend fuel injector life & increase combustion fuel efficiency Remove free water to saturation point with high single pass efficienc (achieve
More informationInstallation and instruction manual for Laing DDC pumps
Installation and instruction manual for Laing DDC pumps Application The Laing DDC series pumps are primarily used for the circulation of cooling liquid in liquid cooled computers. Construction - The Laing
More informationImproving the flood resistance of your home. Advice sheet 6: Flood-resilient floors
Improving the flood resistance of your home Advice sheet 6: Flood-resilient This sheet provides guidance on identifying different types of floor, assessing the routes floodwater may enter, and describes
More informationBritish Standard Underground Hydrant Range
British Standard Underground Hydrant Range 2 THE NEW AVK BRITISH STANDARD HYDRANT RANGE AVK are the renowned market leading innovators, manufacturers and suppliers of BS 750 fire hydrants into the UK,
More informationCharacterization of Greenhouse Gas Emissions Involved in Oil and Gas Exploration and Production Operations
Characterization of Greenhouse Gas Emissions Involved in Oil and Gas Exploration and Production Operations Review for the California Air Resources Board by Angela Zahniser What greenhouse gas (GHG) emissions
More informationMFH-5057 Ford Small-Block V-8 Fresh Water Cooling Kit Instructions
MFH-5057 Ford Small-Block V-8 Fresh Water Cooling Kit Instructions MONITOR PRODUCTS, INC. 15400 Flight Path Dr Brooksville, FL 34604 Tel: 1-800-334-4591 or 352-544-2620 Sales: ext 201 Technical Support:
More informationDrain Back systems Made in Germany
Drain Back systems Made in Germany State-of-the-art technology Made in Germany Besides high-performance flat plate collectors the company STI also manufactures Drain Back systems. Many years of experience
More informationInstallation & Operating Instructions
300 G R A V I T Y F E D Installation & Operating Instructions Note: Do not attempt to operate this unit before reading the manual thoroughly Manufactured by Evolution Aqua Ltd. Evolution House Kellett
More information6.7L Diesel Fuel System Contamination Diagnosis and Service Procedure Job Aid (Revised March, 2012)
6.7L Diesel Fuel System Contamination Diagnosis and Service Procedure Job Aid (Revised March, 2012) Fuel contamination on 6.7L diesel engines can damage fuel system components including the High Pressure
More informationSAMPLE GUIDE SPECIFICATIONS FOR OSTERBERG CELL LOAD TESTING OF DEEP FOUNDATIONS
Page 1 of 9 SAMPLE GUIDE SPECIFICATIONS FOR OSTERBERG CELL LOAD TESTING OF DEEP FOUNDATIONS 1. GENERAL REQUIREMENTS 1. Description of Work: This work consists of furnishing all materials, equipment and
More informationMinor losses include head losses through/past hydrants, couplers, valves,
Lecture 10 Minor Losses & Pressure Requirements I. Minor Losses Minor (or fitting, or local ) hydraulic losses along pipes can often be estimated as a function of the velocity head of the water within
More informationEXPERIMENTAL AND CFD ANALYSIS OF A SOLAR BASED COOKING UNIT
EXPERIMENTAL AND CFD ANALYSIS OF A SOLAR BASED COOKING UNIT I N T R O D U C T I O N Among the different energy end uses, energy for cooking is one of the basic and dominant end uses in developing countries.
More informationAIR PUMPS & ACCESSORIES
AIR PUMPS & ACCESSORIES Page Chapter 8 2 ECO-Oxy 3 ECO-Oxy 4 AIR Stones 5 AIR-Sets 6 Accessories 7 Pond Aerators 8 Spindrifter 9 OXY-Light 10 Spindrifter Bottom Drain Chapter 8 page 1 Chapter 8 page 1
More informationSpill Containment. Contents
Contents IBC Bund, Spill Pallet or Sump Pallets 2-14 IBC Bunds - User Healthy & Safety Instructions 15-16 Spill Trays, Drum Bunds & Drum Pallets 17-25 Tank Bunds 26-28 Standard Sized Bunds 29 Custom Built
More informationAll Products Brochure
All Products Brochure Rental Pioneer Pump design and build the largest range of dry prime portable pumps in the world. With over forty models of high flow and high pressure pumps, the company has a pump
More informationChecklist for plans to Construct, Alter or Repair An Individual Subsurface Sewage Disposal System
Checklist for plans to Construct, Alter or Repair An Individual Subsurface Sewage Disposal System An application for the construction or alteration of an individual subsurface sewage disposal system shall
More informationSECTION 02150 REMOVAL OR ABANDONMENT OF EXISTING UTILITIES AND UNDERGROUND STRUCTURES. 1. Trench excavation, backfill, and compaction; Section 02250.
02150-1 of 6 SECTION 02150 REMOVAL OR ABANDONMENT OF EXISTING 02150.01 GENERAL A. Description Removal or abandonment of existing utilities and underground structures shall include, but not necessarily
More informationVolkswagen Jetta, Golf, GTI 1999, 2000 2.8 Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)
17 Engine-Lubrication (Page GR-17) Lubrication system components, removing and installing Oil filter housing, disassembling and assembling Oil pan, removing and installing Oil pressure and oil pressure
More informationELECTRIC PERISTALTIC MORTAR POINTING PUMP
ELECTRIC PERISTALTIC MORTAR POINTING PUMP pointing gun & control valve ACF405 PERISTALTIC PuMP hopper feed roller & tube pump for refurbishment & repair trades heritage & conservation bridge & underground
More informationVX Series Pumps Rotary Lobe Pumps designed for abrasive and viscous liquids. HIGH PERFORMANCE PUMPS DESIGNED FOR TOUGH APPLICATIONS ENGINEERED TO WORK
ENGINEERED TO WORK HIGH PERFORMANCE PUMPS DESIGNED FOR TOUGH APPLICATIONS VX Series Pumps Rotary Lobe Pumps designed for abrasive and viscous liquids. Industry Agriculture Mining Biogas Agriculture Wastewater
More informationAfter reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE
86 :: Certificate in Construction Supervision (CIVIL) 12 ROOF 12.1 INTRODUCTION The structure provided to cover the house surface (floor) is known as roof. For different situation and requirement, it is
More informationCartridge Filter Application Notes
Industrial Water Purification (800) CAL-WATER Cal Water 1961 Petra Lane Placentia, CA 92870 FAX: (714) 792-0794 Web Page / Email: www.cal-water.com Cartridge Filter Application Notes Cal Water offers a
More informationLearning Objectives. History of Vacuum Testing for Precast. Vacuum Testing. Terminology and purpose
: It Just Sucks! Presented by: Darryl Cloud Concrete Sealants, Inc. Learning Objectives In this course, you will learn: Terminology for Watertightness Equipment Tips, Tricks, and FAQ s History of Vacuum
More informationSpill Containment. Contents
Contents IBC Bund, Spill Pallet or Sump Pallets 3-9 IBC Spill Containment Bund - User Healthy & Safety Instructions Spill Trays, Drum Bunds & Drum Pallets 11-18 Tank Bunds 19-21 Standard Sized Bunds 22
More informationCFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER
International Journal of Advancements in Research & Technology, Volume 1, Issue2, July-2012 1 CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER ABSTRACT (1) Mr. Mainak Bhaumik M.E. (Thermal Engg.)
More informationDIESEL FUEL CONDITIONING
COD FILTRATION DIESEL FUEL CONDITIONING REMOVE WATER & PARTICLES TO EXTEND FUEL INJECTOR LIFE & INCREASE COMBUSTION ENGINE FUEL EFFICIENCY Remove free water to saturation point with high single pass efficiency
More informationSeptic System Owner s Manual
Septic System Owner s Manual Sponsored by: copyright 2013 No part of this publication may be reproduced without our consent. www.callbrownies.com Brownie s Septic and Plumbing has provided quality service
More informationCHAPTER 11 STORM DRAINAGE
CHAPTER 11 STORM DRAINAGE SECTION 11 GENERAL 11.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of storm drainage. 11.2 Where required. All roofs,
More informationLand Disturbance, Erosion Control and Stormwater Management Checklist. Walworth County Land Conservation Department
Land Disturbance, Erosion Control and Stormwater Management Checklist Walworth County Land Conservation Department The following checklist is designed to assist the applicant in complying with the Walworth
More informationROTARY DRILLING COMPANY
DHR-200 (Depth Range 4000 m) DHR-200 (Depth Range 4000 m) TF 25 (Romanian) - 1 1/4" drilling line - 602 BAYLOL EDDY Current Brake KANIZSA-00 (DKG) - mast 42 m (17') max. hook load with 10 lines = 200 tons
More informationSolids Capture. Brian Vinci, Ph.D. James M. Ebeling, Ph.D. Freshwater Institute Shepherdstown, WV
Solids Capture James M. Ebeling, Ph.D. Research Engineer Aquaculture Systems Technologies, LLC New Orleans, LA Brian Vinci, Ph.D. Freshwater Institute Shepherdstown, WV 1 Effluent Treatment Treatment Required
More information