SUMMARY - RELATIONSHIP BETWEEN QUALITY OF SERVICE DEMANDED AND TARIFF
|
|
|
- Thomas Weaver
- 10 years ago
- Views:
Transcription
1 SUMMARY - RELATIONSHIP BETWEEN QUALITY OF SERVICE DEMANDED AND TARIFF PA Consulting Services SA Authors: C. Guidi / J. Espain - / J. García Argentina Restructuring of Electric Sectors in Latin America has been characterized by the concession of service supply, establishing: a) the quality conditions under which such service should be provided; b) a penalty regime in the case of verifying non compliance with such conditions; and c) maximum tariffs to be charges for the service. Thus, in each case, an implicit relationship between the price paid by the customer and the service and the related quality was established. Even though these aspects were evaluated by the different bidders when they submitted their offers for the different areas given in concession, they had no definite experience about the implications of this type of regime, and after a certain period of application, similar concerns started to arise in various countries whether it was possible to provide the service according to the quality demands established and if tariffs really reflected the service supply under those conditions. This situation reached various degrees of relevance depending on the characteristics of the concessions and quality regimes in each country, but in general terms it gave way to the beginning of some research about this particular subject. The natural opportunity has been the moment of the tariff review, which generally takes place every 4 years, counted from the take-over date. predictable quality, have proved to be within the limits established. In some cases, there is evidence of limits way below the admissible ones. Values also presented a significant similitude among themselves and a good relationship with their Distribution Costs. As regards areas, the opposite situation was verified. In most of the cases, the resulting simulation values proved the impossibility of complying with the demand levels established, as well as the presence of a great dispersion among the results obtained, depending mainly on the facilities characteristics, in particular, the feeders length. In these cases, the absence of a relationship between Distribution Costs incorporated in tariffs and the quality of service predicted to be obtained through an efficient network management was verified. In most of the cases it was also verified that the necessary costs to increase quality of service levels are of a magnitude comparable to the Distribution Cost itself, even not making it possible to achieve the demanded levels. Some countries have undertaken studies tending to determine if the typical circuits for each type of area to serve enabled to provide the service according to the requirements established in the quality standards, as well as the economic impact of the standard application regarding the necessary resources for the execution of the requested controls and their relationship with tariff. The results obtained prove that quality requirements might not be in agreement with tariffs in some of the served areas. In some cases, they are even impossible to comply with considering the network configuration considered in tariff determination. This situation has led to more in-depth studies about the actual companies networks in order to determine their relationship with the typical circuits considered for tariff determination and with the quality of service levels demanded. These studies have yielded different results depending on the characteristics of the area served. The conclusions are that in all the cases analyzed for areas, the simulations results as regards the
2 RELATIONSHIP BETWEEN QUALITY OF SERVICE DEMANDED AND TARIFF Authors: C. Guidi / J. Espain - / J. García PA Consulting Services SA Argentina SYNOPSIS: depending on the characteristics of the area served. These results will be presented in this paper. Restructuring of Electric Sectors in Latin America has been characterized by the concession of service supply, establishing: a) the quality conditions under which such service should be provided; b) a penalty regime in the case of verifying non compliance with such conditions; and c) maximum tariffs to be charges for the service. Thus, in each case, an implicit relationship between the price paid by the customer and the service and the related quality was established. Even though these aspects were evaluated by the different bidders when they submitted their offers for the different areas given in concession, they had no definite experience about the implications of this type of regime, and after a certain period of application, similar concerns started to arise in various countries whether it was possible to provide the service according to the quality demands established and if tariffs really reflected the service supply under those conditions. This situation reached various degrees of relevance depending on the characteristics of the concessions and quality regimes in each country, but in general terms it gave way to the beginning of some research about this particular subject. The natural opportunity has been the moment of the tariff review, which generally takes place every 4 years, counted from the take-over date. Some countries have undertaken studies tending to determine if the typical circuits for each type of area to serve enabled to provide the service according to the requirements established in the quality standards, as well as the economic impact of the standard application regarding the necessary resources for the execution of the requested controls and their relationship with tariff. The results obtained prove that quality requirements might not be in agreement with tariffs in some of the served areas. In some cases, they are even impossible to comply with considering the network configuration considered in tariff determination. This situation has led to more in-depth studies about the actual companies networks in order to determine their relationship with the typical circuits considered for tariff determination and with the quality of service levels demanded. These studies have yielded different results RELATIONSHIP BETWEEN QUALITY OF SERVICE DEMANDED AND TARIFF Methodology The quality of service supplied by a distribution company is generally evaluated through a series of performance indicators that monitor service technical and commercial aspects. The present paper focuses on the technical aspects (Technical Service and Product), since they are closely related to the network characteristics and the market they serve. As regards the Technical Product, only the voltage level has been analyzed and as to the Technical Service, outage frequency and duration indicators have been contemplated. In every case and through a simulation, the analysis has been based on the determination of the quality expected to be obtained in networks of various characteristics operated under efficiency conditions and quality has been associated with distribution costs that are representative of those characteristics. The results obtained have been considered through multiple studies made in various countries of Latin America, such as Peru, Chile and Argentina, as a result of a tariff revision or a particular research on the predictable quality conditions. For the purposes of the present analysis, three types of markets served by networks of various characteristics have been selected. High-Density, and. The markets analyzed have turned out to be comparable among themselves, and even though there are peculiarities in the facilities serving them, depending on the company and country analyzed, the main common characteristics in each one of them have been the following: High-density urban market is characterized for being supplied through underground networks and MV/LV transforming modules over 6 kva. Facilities associated to the urban-type market are characterized
3 by overhead pole networks and MV/LV transforming modules in the order of 3 kva. As regards the rural type market, the facilities characteristics serving it are long-length MV network and small capacity MV/LV transformers. The following figures schematize the representative circuits of each one of the cases under analysis. High-Density Market HV Overhead Pole Two HV transmission line MV HV Line Cliente Especi HV/ MV transf. LV Underground Diversion LV MV/ LV Transf. MV Closure MV Supply Technical Service Interruptions LV MV Supply Underground network Market 1x25 kva Cliente Especi HV/ MV Transf. k1 x 25 MVA MV One HV transmission line Cierre en extremos The analysis tasks performed comprised the simulation of the typical circuit behavior considered in the VAD calculation, in the countries where tariff calculations are based on this methodology and the behavior simulation of the actual networks, operated under efficiency conditions, for the areas that are representative of each one of the markets under study. Simulations comprised the HV and MV network up to the MV/LV terminals, since in average terms 9 % of the interruption impacts undergone by users are originated in these facilities. Through this methodology, maps of the predictable quality could be elaborated through an efficient management of the networks of each MV/LV transforming center, as indicated in the Figure below. LV network Aerial closure MV/ LV. Tranf. LV Network Market
4 The results of the simulations performed for the different cases analyzed, consolidated by type of market served, are summarized in the figures below. Interruptions Frequency/semester Duration Time/Semester (hs) High Density Max. Freq. Min.Freq. Avge Freq. High Density Max. Time Min. Time Avge. Time Results have proved a great value homogeneity for High-Density cases and a great value dispersion in the case of rural markets, depending mainly on the characteristics of their length. As regards the impact produced on the different voltage level facilities, a high HV network participation has been evident as regards area interruption level, decreasing towards the lower density areas, and showing an insignificant participation in areas. % interruption impact 1% 9% 8% 7% 6% 4% 3% 2% 1% % HV Network. MV Network As regards the participation of the main components of the facilities for each type of network analyzed, the impact of each component in the number and duration of the interruptions has proved to depend mainly on the topology and configuration of each type of network. The following figures show the impact percentage of each element in the Interruption Duration (D) and the Number of Interruptions (N). High-Density Area 9% 6% 46% FUS TRAFOS SECC LINES INTER R6KV 41% 18% 23% 9% % D PARTICIPATION % N PARTICIPATION Area 11% 36% 6% 29% FUS SECC TRAFOS LINES INTER R6KV 29% 3% 4% 5 % D PARTICIPATION % N PARTICIPATION As a result of the comparison of the values obtained with the demand levels established in each particular case, compliance with those values in general terms has been verified in high-density urban areas and urban areas. In the case of areas, non compliance has been verified practically in all demand cases. In the case of areas, various operation and control devices have been incorporated to the simulation in order to improve frequency and duration indicators, such as telecontrol, re-connectors and isolating switches, which were taken into account at the moment of determining the network payment value for the tariff calculation. Technical Product Voltage Level As to Voltage Level, since this parameter is habitually pre-established when the facilities are designed, the results of the simulations run on the typical circuits proved the compliance with design conditions. In the
5 case of actual networks operated in an efficient way, the values obtained have resulted in voltage drop between 5 % and 7 % for MV network, and between 8 % and 1 % in LV network in areas, and between 8 % and 11 % in the MV network in areas. In the case of areas, it has been necessary to incorporate a simulation of the voltage regulator operation throughout the facilities, resulting in some cases a significant number, that was considered for payment remuneration of the networks at the moment of the tariff calculation. great homogeneity and almost linear relationship among them has turned out for the High-Density area, turning this area into one where both values are perfectly predictable. This situation brings about dispersion areas, depending on the particular features of the networks within which both quality levels and distribution costs are predicted to be. The following graphs represent interruption frequency and time values predictable for each one of the areas under study based on their corresponding distribution costs. 12 Distribution-Related Costs Distribution cost values associated to each one of the facilities that are representative of the areas analyzed present some variations brought about by the various methodologies used for the calculations and to differences in costs, calculation dates and type of related equipment, typical of each company and country studied. Furthermore, the analysis made has performed an adequate value comparison and association, resulting in a value alignment in cases and a huge dispersion in the cases, which might be considered as a reference in the subject. The Figure below represents all quality indicators together, representative of frequency and duration of the interruptions and distribution costs associated to each one of the areas analyzed. Frquency/Semester Max. Freq. Min. Freq. Avge. Freq. Max. Time Min. Timen Avge. Time US$/kW-mes Hours/ Semester US$/kW-month It may be observed that even though there is a similar tendency in cost curves with those of the quality of service predictable for each type of networks, the latter show a greater dispersion. Dispersion in quality levels associated to rural areas is due to the fact that the analysis included facilities with very different extensions, in some cases even up to 5 times longer than the lengths between them. The great dispersion in quality levels is not related to the unit capacity costs. As a result of the analysis and by connecting the quality of service values predictable for the various types of networks with the corresponding distribution costs, a Frequency/Semester Hours/Semester US$/kW-month US$/kW-mes The verified linearity for the High Density area may be observed, as well as the increasing value dispersion towards the area. Conclusions To conclude, it may be mentioned that in all the cases analyzed for areas, the simulations results as regards the predictable quality, have proved to be within the limits established. In some cases, there is evidence of limits way below the admissible ones. Values also presented a significant similitude among themselves and a good relationship with their Distribution Costs. As regards areas, the opposite situation was verified. In most of the cases, the resulting simulation values proved the impossibility of complying with the demand levels established, as well as the presence of a great dispersion among the results obtained, depending mainly on the facilities characteristics, in particular, the feeders length. In these cases, the absence of a relationship between Distribution Costs incorporated in tariffs and the quality of service predicted to be obtained through an efficient network management was verified. In most of the cases it was also verified that the necessary costs to
6 increase quality of service levels are of a magnitude comparable to the Distribution Cost itself, even not making it possible to achieve the demanded levels.
ESB Networks Response. ERGEG Consultation. Voltage Quality Regulation in Europe
NETWORKS ESB Networks Response to ERGEG Consultation on Voltage Quality Regulation in Europe Date: 22 February 2007 Distribution System Operator ESB Networks Page 1 of 12 Contents 1.0 INTRODUCTION...3
A Network Reference Model for Distribution Regulation and Planning: the Spanish Case
A Network Reference Model for Distribution Regulation and Planning: the Spanish Case Jesús Pascual Peco González Instituto de Investigación Tecnológica (IIT) Universidad Pontificia Comillas, Madrid http://www.iit.upco.es
Phase Attribute Identification using GPS Technology
Phase Attribute Identification using GPS Technology Date 11 June 2009 John Sinclair Power Quality Manager Slide 1 Topics of Discussion Remote Phase Identification How it works Principals of operation Benefits
SURVEY OF HARMONIC DISTORTION IN LV AND MV NETWORKS: RESULTS AND CORRECTIVE STRATEGIES
SURVEY OF HARMONIC DISTORTION IN LV AND MV NETWORKS: RESULTS AND CORRECTIVE STRATEGIES E Bompard*, E Carpaneto*, R Napoli*, P Ribaldone**, C Vercellino** * Dipartimento di Ingegneria Elettrica Industriale,
Power products and systems. Intelligent solutions for power distribution Zone concept
Power products and systems Intelligent solutions for power distribution Zone concept Securing continuous power supply ABB is one of the world's leading power and automation technology companies whose products,
Low Voltage Asset Management (LVAM) The key to reliable and safe electricity
Low Voltage Asset Management (LVAM) The key to reliable and safe electricity Archie Jaykaran Distribution Division Eskom SA Contents Change drivers Scope, Approach, Project status LV Planning and Design
Chapter 1. Network Structures
Chapter 1 Network Structures Definition Standard IEC 60038 defines voltage ratings as follows: Low voltage (): for a phase-to-phase voltage of between 100 V and 1,000 V, the standard ratings are: 400 V
BL20A0501 Electricity distribution technology. Introduction Jarmo Partanen
BL20A0501 Electricity distribution technology Introduction Jarmo Partanen Introduction to ED Prof. Jarmo Partanen, D.Sc Jukka Lassila Topics of lectures Introduction to Electricity Distribution, 27.10
VOLTAGE CONTROL IN DISTRIBUTION SYSTEMS AS A LIMITATION OF THE HOSTING CAPACITY FOR DISTRIBUTED ENERGY RESOURCES
VOLTAGE CONTROL IN DISTRIBUTION SYSTEMS AS A LIMITATION OF THE HOSTING CAPACITY FOR DISTRIBUTED ENERGY RESOURCES C. Schwaegerl*, M.H.J. Bollen, K. Karoui #, A. Yagmur + *Siemens AG, # Tractebel STRI AB
ELECTRICITY DISTRIBUTION TARIFFS The Chilean Experience. Hugh Rudnick Pontifícia Universidad Católica de Chile
ELECTRICITY DISTRIBUTION TARIFFS The Chilean Experience Hugh Rudnick Pontifícia Universidad Católica de Chile Brasilia, June 2009 Objective Describe the building of the electricity distribution tariff
Medium Voltage (MV) & High Voltage (HV) Training Module 6. Date of the presentation
Medium Voltage (MV) & High Voltage (HV) Training Module 6 Date of the presentation Electrical System Basics MV vs. HV - Definitions Differences between USA and the rest of the world IEC define a high voltage
Agenda do Mini-Curso. Sérgio Yoshio Fujii. Ethan Boardman. [email protected]. [email protected]
Agenda do Mini-Curso Sérgio Yoshio Fujii [email protected] Ethan Boardman [email protected] Agenda do Mini-Curso Sistemas de Distribuição (DMS) Characteristics of Distribution Network
For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V - 690 V - 1000 V (at 50 Hz)
24 1. NETWORK CONFIGURATIONS definition Standard IEC 38 defines voltage ratings as follows: - Low voltage () For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V - 690
ES281 COMPANY-SPECIFIC APPENDICES TO ENA ENGINEERING RECOMMENDATION G81 PART 1
ES281 COMPANY-SPECIFIC APPENDICES TO ENA ENGINEERING RECOMMENDATION G81 PART 1 Design and Planning Specification for New Low Voltage Installations for Housing Developments 1. SCOPE This appendix to ENA
Understanding Power Factor and How it Affects Your Electric Bill. Presented by Scott Peele PE
Understanding Power Factor and How it Affects Your Electric Bill Presented by Scott Peele PE Understanding Power Factor Definitions kva, kvar, kw, Apparent Power vs. True Power Calculations Measurements
Comparative Report. Pacific Region Electricity Bills
Comparative Report Pacific Region Electricity Bills July 2014 Letter from the CEO In September 2013, the URA Staff prepared and released its first Electricity Bills Comparison Report for the Pacific region.
Audit Report Rottnest Island 2015 Network Quality and Reliability of Supply Performance Audit - Operation of Compliance Monitoring Systems
ABN 20 009 454 111 Rottnest Island 2015 Network Quality and Reliability of Supply Performance Audit - Operation of Compliance Monitoring Systems Telephone: +61 8 9260 0003 Fax: +61 8 9225 7447 E-Mail:
Developing a Utility/Customer Partnership To Improve Power Quality and Performance
Developing a Utility/Customer Partnership To Improve Power Quality and Performance Mark McGranaghan Electrotek Concepts Knoxville, TN Abstract Many industrial and commercial electric customers now require
BC Hydro. Electric Distribution System Cost of Service Study
BC Hydro Electric Distribution System Reimer Consulting Group Inc. Arnie Reimer May 7, 2010 Table of Contents 1. Executive Summary... 3 2. BC Hydro Electric Distribution System... 4 2.1. General Description...
How the National Grid System Operates. Chris Gorman Lead Account Executive Syracuse
How the National Grid System Operates Chris Gorman Lead Account Executive Syracuse 2 Parts of the Electric System Parts of the Electric System 1. Generating Station: Produces Electricity. 2. Transmission
Trends in Power Quality
Trends in Power Quality Herwig Renner Graz University of Technology Institute for Electrical Power Systems Contents Results from long term harmonic and flicker measurement in Austria Discussion flicker
ESB Networks Ltd Statement of Charges
ESB Networks Ltd Statement of Charges Revision Date: 9/2014 Revision No.: 11 Document No: DOC-101209-AXR Issued by: ESB NETWORKS LTD Approved by : CER Effective Date: 01/10/2014 Commercial and Renewable
F.C. Chan General Manager, CLP Engineering Ltd., Hong Kong SAR, China
ELECTRIC POWER DISTRIBUTION SYSTEMS F.C. Chan General Manager, CLP Engineering Ltd., Hong Kong SAR, China Keywords: Distribution system planning, Load characteristics, Subtransmission Lines, Distribution
Networks. ESB Networks Ltd Basis of Charges for Connection to the Distribution System. Commercial and Customer Asset Management ESB Networks Ltd.
Networks ESB Networks Ltd Basis of Charges for Connection to the Distribution System Revision Date: 14/01/20010 Revision No.: 1 Document No: DOC-10129-AXQ Issued by: ESB Networks Ltd Approved by : CER
Comparison of GIS and AIS systems for urban supply networks
Comparison of GIS and AIS systems for urban supply networks Studies carried out by ABB show that for urban supply networks the combination of HV gas-insulated switchgear (GIS) and HV cable has important
Isolated-Parallel UPS Configuration
Isolated-Parallel UPS Configuration 1 Inhalt 1 Introduction... 4 2 IP systems configuration... 6 3 Projects... 17 4 Conclusions... 17 2 Abstract The isolated-parallel UPS configuration has become well
Enel s experience on smart grids
Enel s experience on smart grids Projects and Strategy Shenzhen, September 2014 Agenda Enel profile Overview of smart grid technologies Smart Grids and Smart Cities projects in Italy and Europe 2 Enel:
Energy Storage Systems in Grid4EU Demo4 and in Other Enel Distribuzione Projects Speaker
Energy Storage Systems in Grid4EU Demo4 and in Other Enel Distribuzione Projects Speaker Enel Distribuzione SpA Enel: a world dimension Focus on major areas of presence NORTH-CENTRAL AMERICA North America,
The calm after the storm
The calm after the storm Human decision support in storm outage recovery Rafael Ochoa, Amitava Sen It s a fact of life that interruptions in an electrical distribution utility happen. Although they can
SGTech Europe 2015 September 22 th Amsterdam. Pedro Gama, Head of SCADA & Telecom Department at EDP Distribuição, SA
Time-Critical Applications - applying the latest tools and techniques to guarantee QoS for time-critical applications and services over IP/Ethernet/MPLS telecom networks Pedro Gama, Head of SCADA & Telecom
ADMS(Advanced Distribution Management System ) in Smart Grid
ADMS(Advanced Distribution Management System ) in Smart Grid 柯 佾 寬 博 士 Yi-Kuan Ke, Ph.D. 2014/03/28 Smart Grid Solution Smart Grid Solution Overview Smart Grid Solutions Smart Network Operation - Distribution
Reliability centered asset management tool
Reliability centered asset management tool The development of RACalc Claes Böös and Richard Göransson Degree project in Electromagnetic Engineering Second Level, 30.0 HEC Stockholm, Sweden 2009 XR-EE-ETK
Network Consulting for Power Grid Optimization
Network Consulting for Power Grid Optimization Project experience in India Network Consulting Competences Page 1 Our worldwide representation Manchester The Hague Denver Schenectady San Diego Houston Mexico
Advanced Protection of Distribution Networks with Distributed Generators
Date:- 8 10 March 2011 Venue: University of Manchester EES-UETP Course title Advanced Protection of Distribution Networks with Distributed Generators Peter Crossley Director of the Joule Centre School
Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear
Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear Index 3 Overview 4 Standard Levels 6 Monitoring & Control 7 Measurements 8 Protection & Logic
Simple Methods for Calculating Short Circuit Current Without a Computer By Dennis McKeown, PE GE Senior System Application Engineer
Simple Methods for Calculating Short Circuit Current Without a Computer By Dennis McKeown, PE GE Senior System Application Engineer A Short Circuit analysis is used to determine the magnitude of short
Proceedings of the 38th Hawaii International Conference on System Sciences - 2005
The use of Multi-Attribute Trade-Off Analysis in Strategic Planning For an Electric Distribution utility: An Analysis of Abu Dhabi Distribution Company Richard D. Tabors, Ph.D. Rick Hornby Tabors Caramanis
THE PER-UNIT SYSTEM. (2) The per-unit values for various components lie within a narrow range regardless of the equipment rating.
THE PER-UNIT SYSTEM An interconnected power system typically consists of many different voltage levels given a system containing several transformers and/or rotating machines. The per-unit system simplifies
AMSC s Superconductor Cable Technologies for Electric Utilities
International Workshop 2014 AMSC s Superconductor Cable Technologies for Electric Utilities Michael Ross, P.E. Managing Director of Superconductor Power Systems AMSC Corporate Facts Headquartered in MA,
Electricity Networks Service Standards: An Overview
Electricity Networks Service Standards: An Overview A Report for the NSW Department of Premier and Cabinet 2 September 2014 Final Report HoustonKemp.com Report Author/s Ann Whitfield Tom Graham Contact
NO-BREAK KS 7e. Concentrated Energy. 2750 kva (50Hz) 3000 kva (60Hz) DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY SYSTEM
NO-BREAK KS 7e Concentrated Energy e 2750 kva (50Hz) 3000 kva (60Hz) DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY SYSTEM Data Centre owners, operators and designers are required to meet ever increasing and
7. Reactive energy compensation
593 7. Reactive energy compensation 594 7. REACTIVE ENERGY COMPENSATION Reactive energy compensation is an important element for reducing the electricity bill and improving the quality of the electrical
4160: THE GREEN 480 MEDIUM VOLTAGE ELECTRICAL SYSTEMS
4160: THE GREEN 480 MEDIUM VOLTAGE ELECTRICAL SYSTEMS for DATA CENTERS Michael Mosman, PE Chief Technical Officer CCG Facilities Integration Incorporated FACILITIES INTEGRATION INCORPORATED MEDIUM VOLTAGE
Calculation of Voltage Sag Indices for Distribution Networks
Calculation of Voltage Sag Indices for Distribution Networks Juan A. Martinez-Velasco, Member, IEEE, Jacinto Martin-Arnedo, Nonmember Abstract This paper is presenting the main results of a work aimed
INTEGRAL REMOTE MANAGEMENT SOLUTION cirwatt b series
Communication system for the management of electrical installations INTEGRAL REMOTE MANAGEMENT SOLUTION cirwatt b series MID Approval Technology for energy efficiency PLC Communications (Power Line Communication)
APPLICATION NOTE USING A MODEL 3060-MS SERIES AS A REGENERATIVE AC SOURCE FOR PV INVERTER TEST APPLICATIONS. Abstract.
USING A MODEL 3060-MS SERIES AS A REGENERATIVE AC SOURCE FOR PV INVERTER TEST APPLICATIONS Abstract This application note describes the necessary procedure to use a standard Pacific Power Source Model
Network Pricing Trends
Network Pricing Trends Queensland Perspective 20 January 2015 Foreword This report has been prepared for Infrastructure Partnerships Australia (IPA). Its purpose is to help build community understanding
OPERATIONS CAPITAL. The Operations Capital program for the test years is divided into two categories:
Filed: September 0, 00 EB-00-0 Tab Schedule Page of OPERATIONS CAPITAL.0 INTRODUCTION Operations Capital funds enhancements and replacements to the facilities required to operate the Hydro One Transmission
Modeling of PV Based Distributed Generator Systems with Diverse Load Patterns
Modeling of PV Based Distributed Generator Systems with Diverse Load Patterns Mehmet H. Cintuglu, [email protected], Armando Altamirano, [email protected] Osama A. Mohammed, [email protected] Energy Systems
V1.8 0 - N ovember 2015. Distribution Network Asset Data Available To Third Parties
V1.8 0 - N ovember 2015 Distribution Network Asset Data Available To Third Parties How To Request Data LinesearchBeforeUDig (http://www.linesearchbeforeudig.co.uk) This service is available 24/7 365 days
Market Growth and New Regulations Demand Network Modernization
CASE ESB NETWORKS: POLE TOP COMMUNICATION INCREASES EFFICIENCY IN IRELAND Viola s solution for remotely operating pole-top reclosers and switches increases reliability, cuts operating costs and helps to
MEDIUM VOLTAGE. Michael Mosman, PE. CCG Facilities Integration Incorporated FACILITIES INTEGRATION INCORPORATED
MEDIUM VOLTAGE ELECTRICAL SYSTEMS for DATA CENTERS Michael Mosman, PE Chief Technical Officer CCG Facilities Integration Incorporated FACILITIES INTEGRATION INCORPORATED CCG Facilities Integration Incorporated
Laboratory 4: Feedback and Compensation
Laboratory 4: Feedback and Compensation To be performed during Week 9 (Oct. 20-24) and Week 10 (Oct. 27-31) Due Week 11 (Nov. 3-7) 1 Pre-Lab This Pre-Lab should be completed before attending your regular
RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0.
Receiver AC-RX2/CS RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. Pin-out 38.1 3 Component Side 1 2 3 7 11 13 14 15
This is a Master s degree level apprenticeship which includes academic learning combined workplace learning and training.
Power Engineer Degree Apprenticeship The UK s energy sector is integral to the prosperity and stability of the UK economy as a whole, delivering an absolutely fundamental service for all its citizens.
C. PROCEDURE APPLICATION (FITNET)
C. PROCEDURE APPLICATION () 495 INTRODUCTION ASSESSMENT OF SCC ASSESSMENT OF CORROSION FATIGUE STRESS CORROSION AND CORROSION FATIGUE ANALYSIS ASSESSMENT OF LOCAL THINNED AREAS 496 INTRODUCTION INTRODUCTION
Understanding Power Impedance Supply for Optimum Decoupling
Introduction Noise in power supplies is not only caused by the power supply itself, but also the load s interaction with the power supply (i.e. dynamic loads, switching, etc.). To lower load induced noise,
Electricity Industry Code. made under the Electricity Act 1994
Electricity Industry Code made under the Electricity Act 1994 Seventeenth Edition: approved 16 July 2014 effective 25 July 2014 This Seventeenth Edition of the Electricity Industry Code pursuant to section
Reduction of Power Losses Using Phase Load Balancing Method in Power Networks
Proceedings of the World Congress on Engineering and Computer Science 009 Vol I WCECS 009, October 0-, 009, San Francisco, USA eduction of Power Losses Using Phase Load Balancing Method in Power Networks
Benchmark Regulation and Efficiency of Electricity Distribution
Pontificia Universidad Católica de Chile Departamento de Ingeniería Eléctrica Benchmark Regulation and Efficiency of Electricity Distribution Hugh Rudnick Bundesnetzagentur Conference Bonn, 25-26 April
Cost Benefit Methodology for Optimal Design of Offshore Transmission Systems
Centre for Sustainable Electricity and Distributed Generation Cost Benefit Methodology for Optimal Design of Offshore Transmission Systems Predrag Djapic and Goran Strbac July 2008 FUNDED BY BERR URN 08/1144
WHITEPAPER CABLE CONDUCTOR SIZING
WHITEPAPER CABLE CONDUCTOR SIZING FOR MINIMUM LIFE CYCLE COST Bruno De Wachter, Walter Hulshorst, Rodolfo di Stefano July 2011 ECI Available from www.leonardo-energy.org/node/156451 Document Issue Control
Analysis of the Brazilian Data Center Power Supplies Market
Analysis of the Brazilian Data Center Power Supplies Market IT Infrastructure Outsourcing Services Compel New Trends for this Growing Market ND27-14 September 2013 Contents Section Slide Numbers Executive
Phase Balancing of Distribution Systems Using a Heuristic Search Approach
Phase Balancing of Distribution Systems Using a Heuristic Search Approach Lin, Chia-Hung*, Kang, Meei-Song**, Chuang, Hui-Jen**, and Ho, Chin-Ying** *National Kaohsiung University of Applied Sciences **Kao
Iman Ziari. M.Sc, B.Eng (Electrical Engineering) A Thesis submitted in Partial Fulfillment of the Requirement for the Degree of. Doctor of Philosophy
Planning of Distribution Networks for Medium Voltage and Low Voltage Iman Ziari M.Sc, B.Eng (Electrical Engineering) A Thesis submitted in Partial Fulfillment of the Requirement for the Degree of Doctor
How To Choose A Transformer
Consider open loop MV network as an example source 1 source 2 NC NC NC or NO main MV switchboard A B Detail design of substation NC NC NC NO NC NC switchboard 1 switchboard 2 switchboard 3 MV MV MV LV
Electric Power Distribution
Electric Power Distribution A S Pabla Consulting Engineer and Former Chief Engineer Punjab State Electricity Board McGraw-Hill New York Chicago San Francisco Lisbon London Madrid Mexico City Milan New
Electricity Service Standards
CODE OF PRACTICE Electricity Service Standards Revised August 2015 Contents 1. Preface... 1 Format... 1 2. Application and Objectives... 2 3. Service Standards... 3 3.1 General... 3 3.2 Particular... 3
A Case Study: How a Utility Automated and Integrated Data/Control for 4000 Pole-Top Switches and Protection Relays, and Reduced its SAIDI
A Case Study: How a Utility Automated and Integrated Data/Control for 4000 Pole-Top Switches and Protection Relays, and Reduced its SAIDI Hervé Delmas, Eng. - Hydro-Quebec Patrick Cossette, Eng. - Cooper
ZONE SELECTIVE INTERLOCKING (ZSI) APPLICATION AND TESTING GUIDE SIEMENS WL UL489 AND UL1066 AIR CIRCUIT BREAKERS
Definition: Zone Selective Interlocking (ZSI) - A method which allows two or more ground fault breakers to communicate with each other so that a short circuit or ground fault will be cleared by the breaker
Technical Trial of Broadband IP/Internet over ESB Power Networks. Engineers Ireland. October 2006
Technical Trial of Broadband IP/Internet over ESB Power Networks Engineers Ireland October 2006 Outline of Presentation 1. Introduction to Broadband Power Line Carrier 2. Trial start up 1. Objectives 2.
Transformers. Special transformers Reactors products
Transformers Special transformers Reactors products Reactors Custom designed, custom built ABB Oy Transformers has extensive experience and numerous references from different reactor applications, having
Digital to Analog Converter. Raghu Tumati
Digital to Analog Converter Raghu Tumati May 11, 2006 Contents 1) Introduction............................... 3 2) DAC types................................... 4 3) DAC Presented.............................
Washington DC Power Sector Overview
Washington DC Power Sector Overview Kenneth (Ken) Glick Public Service Commission Of the District of Columbia December 8, 2014 DC Power Market Area - Summary Single electric utility that has divested itself
1ED Compact A new high performance, cost efficient, high voltage gate driver IC family
1ED Compact A new high performance, cost efficient, high voltage gate driver IC family Heiko Rettinger, Infineon Technologies AG, Am Campeon 1-12, 85579 Neubiberg, Germany, [email protected]
ICM Project Station Infrastructure and Equipment
EB 0 00 Schedule B. ( pages) ICM Project Station Infrastructure and Equipment (THESL) EB 0 00 Schedule B. I EXECUTIVE SUMMARY 0. Project Description Many Municipal Substations (MS) located outside of downtown
EMTP STUDIES PERFORMED TO INSERT LONG AC CABLES IN THE FRENCH GRID
Tension (kv) Impedance (Ohms) EMTP STUDIES PERFORMED TO INSERT LONG AC CABLES IN THE FRENCH GRID frequency (Hz) Simon DESCHANVRES Yannick VERNAY RTE, CNER, Substations Department t (ms) EMTP-RV Users Group
Loop Bandwidth and Clock Data Recovery (CDR) in Oscilloscope Measurements. Application Note 1304-6
Loop Bandwidth and Clock Data Recovery (CDR) in Oscilloscope Measurements Application Note 1304-6 Abstract Time domain measurements are only as accurate as the trigger signal used to acquire them. Often
ASSET MANAGEMENT LCNI 2014 Wednesday 22 nd October. Jennifer Woodruff Innovation & Low Carbon Networks Engineer
ASSET MANAGEMENT LCNI 2014 Wednesday 22 nd October Jennifer Woodruff Innovation & Low Carbon Networks Engineer Asset Management Efficient asset management ensures that risk is effectively managed and returns
RX-AM4SF Receiver. Pin-out. Connections
RX-AM4SF Receiver The super-heterodyne receiver RX-AM4SF can provide a RSSI output indicating the amplitude of the received signal: this output can be used to create a field-strength meter capable to indicate
Transformers Energy efficient transformer solutions European Minimum Energy Performance Standard (MEPS)
Transformers Energy efficient transformer solutions European Minimum Energy Performance Standard (MEPS) 2 European MEPS for transformers The EU MEPS (European Minimum Energy Performance Standard) Transformers
Federal Wage System Job Grading Standards for Electric Power Controlling, 5407. Table of Contents
Federal Wage System Job Grading Standards for Electric Power Controlling, 5407 Table of Contents WORK COVERED... 2 WORK NOT COVERED...2 TITLES... 2 GRADE LEVELS... 2 SPECIAL ADDITIONAL RESPONSIBILITIES...
Network Demand and Customer Connections Forecasting Procedure Power Networks
Network Demand and Customer Connections Forecasting Procedure Power Networks 1 Forecast Purpose...3 2 Forecast Scope...3 3 Reference...3 4 Characteristics of a robust forecasting process...3 4.1 Forecast
3-PHASE LOW VOLTAGE NETWORK LOAD BALANCER : A COST EFFECTIVE SOLUTION TO LINE VOLTAGE VARIATIONS
3-PHASE LOW VOLTAGE NETWORK LOAD BALANCER : A COST EFFECTIVE SOLUTION TO LINE VOLTAGE VARIATIONS Pierre FRISTOT Olivier CONSTANT Catherine MONCET Omegawatt - France Omegawatt - France SDET - France [email protected]
Rack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V
14.5GHZ 2.2KW CW GENERATOR GKP 22KP 14.5GHz WR62 3x400V UTILIZATION OF GKP 22KP GENERATOR With its characteristics of power stability whatever the load, very fast response time at a pulse, low ripple,
Fuse Selection Method Module 2. Date of the presentation
Fuse Selection Method Module 2 Date of the presentation Fuse Selection When selecting LV fuses certain important information must be known. 1.System Voltage This is the voltage of the system or distribution
Cost-effective Distribution Reliability Improvement Using Predictive Models
Cost-effective Distribution Reliability Improvement Using Predictive Models Dr. Julio Romero Agüero Sr. Director, Distribution Quanta Technology Raleigh, NC [email protected] 919-334-3039 Table
MOBILE SYSTEM FOR DIAGNOSIS OF HIGH VOLTAGE CABLES (132KV/220KV) VLF-200 HVCD
MOBILE SYSTEM FOR DIAGNOSIS OF HIGH VOLTAGE CABLES (132KV/220KV) VLF-200 HVCD VERY LOW FREQUENCY (VLF) - PARTIAL DISCHARGES AND TANGENT DELTA HV/EHV POWER CABLES DIAGNOSTIC AND ON-SITE FIELD TESTING WITH
3. TYPES OF SERVICE AVAILABLE. 3.1 Scope
3. TYPES OF SERVICE AVAILABLE 3.1 Scope UI supplies 60 hertz, alternating current with different voltage and ampere ratings. Not all voltage and ampere ratings are available throughout the entire service
Siemens Fusesaver. Highest availability and cost savings for your MV distribution network. www.siemens.com/fusesaver
www.siemens.com/fusesaver Siemens Fusesaver Highest availability and cost savings for your MV distribution network Answers for infrastructure and cities. 2 In high demand: An intelligent solution Improving
