Product Data Sheet. Trespa Meteon Architectural System is a flat decorative façade installed on a specifically designed Benchmark Karrier Panel.
|
|
- Opal Wilkinson
- 7 years ago
- Views:
Transcription
1 Trespa Meteon Architectural System is a flat decorative façade installed on a specifically designed Benchmark. FAÇADE DATA Material TRESPA Meteon is a flat board, based on thermosetting resins, homogeneously reinforced with wood based fibres and manufactured under high pressure and at high temperatures according to the European Standard EN 438 and to ISO The façade panel has an integrated decorative surface using proprietary EBC technology. Available in a wide choice of finishes; metallics, wood decors, naturals and uni-colours - they can also be custom-made. Dimensions Typical standard board sizes are 1836mm x 2526mm and 1506mm x 3026mm. Maximum panel size available is 4200mm x 2100mm. Face panel thickness : 8mm* and 10mm as standard. 13mm SF option is also available. *Available for Benchmark FF system applications only. Please Note: Dimensions are restricted to 1196mm x 596mm or 1000mm x 1000mm maximum with the alternative secret fix method (please see page 3). All sizes indicated above exclude 10mm joint. Sizes can be tailored to the build option - please contact Benchmark Technical Services for more information. Product Tolerances Length 1mm +1mm Width 1mm +1mm Thickness 1mm +1mm Flatness (per metre) 2mm +2mm Squareness 1mm +1mm Thickness, sides straightness, rectangularity and surface flatness are all in accordance with BS EN Fire Standard TRESPA Meteon boards have the reaction to fire classification: Class D, s2, d0 in accordance with EN :2002 Fire Classification of Construction Products and Building Elements, EN and ISO FR- Fire Retardant TRESPA Fire Retardant boards have the reaction to fire classification: Class B, s2, d0 in accordance with standards stated above. Environmental TRESPA Meteon boards are certified according to the environmental management system standard ISO 14001:2004, awarded by Lloyds register. Greenfield Business Park No 2 Flintshire, North Wales Tel: +44 (0) info@kingspanbenchmark.com Page 1
2 KARRIER PANEL DATA Insulation Core Polyisocyanurate (PIR): EcoSafe with zero Ozone Depletion Potential (zero ODP). Product Tolerances Length 2mm +2mm Width 2mm +2mm Thickness 2mm +2mm End Squareness 3mm +3mm Flatness (per metre) 2mm +2mm Available Lengths Standard length is 1.8 to 12 metres. Panel lengths up to 17 metres are available. Panels less than 1.8 metres long can be supplied and are subject to an extra charge. These panels cannot be end lapped. Materials Steel Substrate S220GD+ZA hot-dip zinc/aluminium Galfan coated metal to BS EN10214: Standard external sheet thickness 0.63mm, standard internal sheet thickness 0.4mm. Coatings - External Sheet Kingspan XL Forté TM. Colour is Merlin Grey. Reverse side of sheet coated with a light grey polyester coating. Factory Applied Side Joint Seal All side joints have a factory-applied seal fitted into the groove to automatically seal the joint between panels. Fire The steel outer and inner facings of the have a Class 1 surface spread of flame to BS476-7: 1987, and are Class 0, as defined by Building Regulations. Biological Benchmark insulated panels are normally immune to attack from mould, fungi, mildew and vermin. No urea formaldehyde is used in the construction, and the panels are not considered deleterious. Coatings - Internal Liner Standard polyester coating developed for use for the internal lining of insulated panels. Standard colour is bright white with an easily cleaned surface. Foodsafe hygienic coating developed for use where the liner is exposed to foodstuffs and is regularly cleaned. Colour white. Kingspan XL Forté TM coating for internal high humidity environments. Colour white. Reverse side of sheet coated with a light grey polyester coating. Greenfield Business Park No 2 Flintshire, North Wales Tel: +44 (0) info@kingspanbenchmark.com Page 2
3 SYSTEM WEIGHT TRESPA Meteon façade system has an overall typical weight depending upon thickness: 8mm; Thickness (mm) Weight (Kg/m²)* mm; Thickness (mm) Weight (Kg/m²)* mm; Thickness (mm) Weight (Kg/m²)* *Based on complete façade system - panel, rail and façade weight. For Project Specific weights, please contact Benchmark Technical Services Department. SYSTEM ATTACHMENT There are three different types of system attachment options which are as follows; Benchmark FF System The Trespa boards will be fixed with rivets to aluminium omega and zed profiles which are, in turn attached to the Karrier panel system. Benchmark SF System The Trespa boards will be fixed invisibly by attaching metal hanging brackets with stainless steel self tapping screws.the Trespa panels are attached to aluminium rails. Each panel has two adjusting points and a fixed point at the top of the panel through the attached brackets. The aluminium rail (powder coated black) is in turn attached to the. FINISH TYPES Certain finish types (typically Metallics) are subject to a directional finish which can appear as a slightly different colour if installed perpendicular to each other. To ensure consistent colour tone and directionality, façade elevations should be ordered in batches. SYSTEM PERFORMANCE Thermal Insulation Thermal Transmittance (U value) calculated in compliance with Building Regulations Approved Documents L2A & L2B (England & Wales), Technical Handbooks Non-Domestic Sections 6 (Scotland), Part F2 (Northern Ireland) and Part L (Republic of Ireland - based on the Overall Heat Loss Method). Thickness (mm) U-value (W/m²K) PLEASE NOTE: For England and Wales; W/m²K is the U-Value used for Notional Building Wall. This U-Value or better is recommended for compliance and can be seen as underlined in the above table. For Scotland; 0.27 W/m²K is the U-Value used for Notional Building Wall. This U-Value or better is recommended for compliance and can be seen as highlighted in bold in the above table. Acoustics TRESPA Meteon Façade System has a single figure weighted sound reduction Rw = 24dB. Sound Reduction Index (SRI) Frequency (Hz) k 2k 4k SRI (db) Greenfield Business Park No 2 Flintshire, North Wales Tel: +44 (0) info@kingspanbenchmark.com Page 3
4 STRUCTURAL LOAD/SPAN TABLE FOR KARRIER PANEL (To be checked against unfactored design wind-loads) Notes: 1. Values have been calculated using the limit state method in the European Recommendations for the Design of Sandwich Panels (ECCS document No ), taking imposed loads, temperature and creep into account. 2. For each value individual and combined load cases with appropriate load factors and temperatures have been considered. These are detailed under Structural Performance in Building Design Section. 3. The table is for dark coloured panels. 4. The following deflection limits have been used: Pressure Loading L/100 Suction Loading L/ For intermediate values linear interpolation may be used. 6. The actual wind suction load resisted by the panel is dependent upon the number of fasteners used and material of the rail. The fastener calculation should be carried out in accordance with the appropriate standard. For further advice please contact Benchmark Envirocare Technical Services. 7. The allowable tolerance between bearing planes of adjacent supports is L/600, where L is the distance between supports. 8. Load span tables for spans outside of those shown are available from the Benchmark Technical Services department. Greenfield Business Park No 2 Flintshire, North Wales Tel: +44 (0) info@kingspanbenchmark.com Page 4
5 PACKING AND STORAGE Façade The packing and storage of Trespa Meteon boards varies slightly dependent upon the attachment method. For the Benchmark FF System, Trespa façade boards will be laid flat on pallets which have supports at not more than 600mm centres. The packs will be wrapped in a waterproof membrane. For the Benchmark SF System, Trespa façade boards will have brackets attached so will be laid on a pallet face to face and back to back with supports in between at maximum of 600mm centres. The pallets will have supports at not more than 600mm centres. For both FF and SF options, boards should be stored in a clean dry frost free room. Treat boards like hardwood. Ensure no moisture forms between boards; do not place moisture sensitive paper layers between the boards. Boards removed from packs should be installed as soon as possible. The boards should not be stored upright leaning against anything as this could cause warping. The Benchmark s are stacked horizontally. Removable hot melt adhesive is laid between each panel. The top, bottom, sides and ends are protected with polystyrene and timber packing and the entire pack is wrapped in polythene. To ensure panels remain in prime condition while stored onsite, the panels need to be stored in a safe, clean and trade free area. Personnel should not walk over packs. Store the panels on a slight slope ensuring any penetrating rainwater drains off and ensure regular inspection the panel packs. Should panel s need to be stored for a period of time in excess of 3 months, please contact Benchmark Technical Services. The number of panels in each pack depends on panel length and weight. Typical pack height is 1100mm (based on 100mm thick panel). Maximum pack weight 1500kg. For information regarding the number of panels per pack, please contact Benchmark Technical Services. Sea Freight Fully timber crated packs are available on projects requiring delivery by sea freight shipping, at additional cost. Alternatively, steel containers can be used. Special loading charges apply. HANDLING Trespa boards are decorative end products so need to be treated with care. Do not slide them, but lift them and prevent getting dirt on and between the panels. If needed to be marked/coded, use adhesive stickers. If the boards have been provided with special protective foil, remove the foil within 24 hours of the boards being removed from the pallet. When lifting a pack of boards with straps fit protective corner pieces under straps. SITE INSTALLATION PROCEDURE Site assembly instructions are available from the Kingspan Benchmark Field Service Department QUALITY & DURABILITY Benchmark components are manufactured from the highest quality materials to rigorous quality control standards, complying with ISO 9001:2000 standard, ensuring long-term reliability and service life. GUARANTEES & WARRANTIES Benchmark will provide external coating and product guarantees on an individual project basis. Greenfield Business Park No 2 Flintshire, North Wales Tel: +44 (0) info@kingspanbenchmark.com Page 5
6 DELIVERY AND OFF- LOADING Transportation of Benchmark packs to site is by road transport (unless indicated otherwise). It is the customer s responsibility to check the site for restrictions (i.e. entrance to site, power lines etc.) and agree a storage area to be used, also to identify the correct type/methods of off-loading/hoisting facilities to be used i.e. crane, crane forks, lifting beam/ slings and airbags, forklift or specialist lifting equipment. Always check the current certification of the crane, crane forks, lifting beam, slings, forklift, or specialist lifting equipment prior to carrying out offloading/hoisting operation (i.e. with correct current SWL Certification). Greenfield Business Park No 2 Flintshire, North Wales Tel: +44 (0) info@kingspanbenchmark.com Page 6
ALUMINIUM. Product Data Sheet
ALUMINIUM Benchmark Aluminium system is available in five different cassette options and installed on a specifically designed Benchmark. Images above courtesy of Euramax FAÇADE DATA Materials Benchmark
More informationInsulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW
Insulated Roof & Wall Panels Trapezoidal Insulated Roof Panels KS1000 RW Overview Kingspan roof panel systems present a superior system compared to conventional multi-part site assembled systems. They
More informationLongspan. Insulated Panels. Architectural Frame to Frame Insulated Panel System. CI/SfB (4-) Rh2 September 2008
Insulated Panels CI/SfB (4-) Rh2 September 2008 INSULATED WALL SYSTEMS Longspan Architectural Frame to Frame Insulated Panel System Approved to LPS 1181 Certificate No. 186a & 260a Longspan is a frame
More informationCERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011
CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS
More informationKingspan Envirodek Structural Green Roof System
Insulated Panels CI/SfB (4-) Rh2 January 2010 INSULATED ROOF SYSTEMS Envirodek Structural Green Roof System Image courtesy of Alumasc Exterior Building Products Ltd. Front cover left image: courtesy of
More informationKingspan Roof Tile. Insulated Panels. Insulated Tile Effect Roofing System. Building to the Power of. CI/SfB. September 2008
Insulated Panels CI/SfB (4-) Rh2 September 2008 Kingspan Roof Tile Insulated Tile Effect Roofing System Building to the Power of Approved to LPS 1181 Certificate No. 279a/10 Combining traditional looks
More informationRockwool Cladding Roll
Rockwool Cladding Roll High performance industrial insulation has been specifically developed for use in lightweight cladding applications to commercial or industrial framed buildings. Cladding Roll U/F
More informationENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.
APR 1200 Acoustic Partition Roll CI/Sfb Ref: APR002 Glass mineral wool roll designed to provide high levels of sound insulation in walls and floors to meet Part E (England & Wales) and Section 5 (Scotland)
More informationSection 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01
Section Built-up Metal Roofs Rail and bracket system Product: Earthwool FactoryClad range Bu01 Standing seam system Product: Earthwool FactoryClad range and Earthwool Universal Slab Bu02 Built-up Metal
More informationBuilt-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5
Cl Sfb (27-9) Rn7 M2 December 2004 Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5 Fesco, Fesco S, Retrofit, Retrofit S, Fesco Fillet, PF,
More informationSTEEL BUILDINGS IN EUROPE. Single-Storey Steel Buildings Part 8: Building Envelope
STEEL BUILDINGS IN EUROPE Single-Storey Steel Buildings Part 8: Building Envelope Single-Storey Steel Buildings Part 8: Building Envelope 2 - ii Part 8: Building Envelope emissions
More informationComposite Panel Firewall Systems
Composite Panel Firewall Systems part of the Protecting more than your business Insulated mineral fibre panels have excellent thermal and acoustic properties, ideal for factory and office partition walls.
More informationThe Kingspan Insulation Price List 1 st January 2013
Insulation The Kingspan Insulation Price List 1 st January 2013 FOR BUILDING FABRIC INSULATION, CAVITY CLOSERS AND MEMBRANES Visit our website: www.kingspaninsulation.co.uk Low Energy - Low Carbon Buildings
More informationSection 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.
Section 5.0 Basements Wall insulated externally Product: Polyfoam ECO Ba01 Wall insulated internally Product: Polyfoam ECO Ba02 Basements Basements Basement design Waterproofing BS 8102: 2009 Code of practice
More informationTR21. I n s u l a t i o n. Low Energy Low Carbon Buildings
I n s u l a t i o n CI/Sfb (27.9) Rn7 M2 Fourth Issue March 2011 TR21 INSULATION FOR FLAT ROOFS WATERPROOFED WITH PARTIALLY BONDED BUILT UP FELT AND MASTIC ASPHALT High performance rigid thermoset insulation
More informationINNOVATIVE. ADAPTABLE. ENERGY EFFICIENT.
INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT. awipanels.com From freezing, sub-zero temperatures to Contents dry heat or high humidity, Mother Nature continually tests the limits of building envelopes. That's
More informationNEW ELECTRICAL SUBSTATION Building 300 SECTION 07 53 23 ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK
ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within
More informationKnauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap
Tile Backing Will not deteriorate in water Easy to score and snap Resistant to mould and mildew Knauf Aquapanel Interior Cement board for wet areas Knauf Aquapanel Interior Cement Board Drywall for Wet
More information1.2.1 1.1.8 PRODUCTBLADEN GT ROCKPANEL STRUCTURE
1..1 1.1.8 PRODUCTBLADEN SHEETS GT page 1 to 6 Rockpanel Structure is a very durable panel with a lightly textured finish, specially developed for use in cladding, fascia, soffit applications. The basic
More informationBETONYP building boards. The modern way of living.
BETONYP building boards The modern way of living. Tough for 30 years. Healthy, debarked pine wood and cement: the raw materials used to produce one of our most successful products for more than three decades.
More informationServices Enclosures and Protected Shafts - Maintaining Compartmentation
Introduction When a fire resisting element is used to provide fire compartmentation, every opening that allows services to pass through the element must be adequately protected by sealing, or fire stopping
More informationSteel-framed Walls. Insulation
Insulation A4/8 SF AW1192 Issue 4 Nov 2012 Steel-framed Walls Insulation guide Helps achieve a 6-star house energy rating Rigid and flexible Kingspan AIR-CELL solutions available Vapour barrier or vapourpermeable
More informationALUMASC ROOF WATERPROOFING MEMBRANES EUROROOF MASTERGOLD ROOF WATERPROOFING MEMBRANE
Alumasc Exterior Building Products Ltd White House Works Bold Road Sutton St Helens Merseyside WA9 4JG Tel: 01744 648 400 e-mail: roofing@alumasc-exteriors.co.uk website: www.alumascroofing.co.uk APPROVAL
More informationArchitectural composite panels
Architectural composite panels June 2012 Composite panels to suit every project Introduction Panel Systems has over 35 years experience in producing high quality composite panels for the construction and
More informationMezzanine. Technical manual
TechNICAL MANUAL 1 Mezzanine Technical manual 2 Varnished (optional) Product class P6 Melamined (optional) Tongue and groove Structural applications STANDARD FEATURE additional options - Chipboard - Varnished
More informationUpstand Rooflight Natural Light Translucent Upstand Systems
Insulated Panels CI/SfB (4-) Rh2 October 2008 ROOFLIGHT SYSTEM Upstand Rooflight Natural Light Translucent Upstand Systems Upstand Rooflight Pre-assembled Rooflight System Introduction The Upstand Rooflight
More informationLow Energy Low Carbon Buildings
I n s u l a t i o n CI/Sfb (27.9) Rn7 M2 Eighth Issue March 2011 TR27 LPC/FM INSULATION FOR FLAT ROOFS WATERPROOFED WITH FULLY ADHERED SINGLE PLY, PARTIALLY BONDED BUILT UP FELT, MASTIC ASPHALT AND COLD
More informationCEILING SYSTEMS. CI/SfB (35) Xy April 2006. [Between us, ideas become reality.] ULTIMA CANOPY. Data sheet. Acoustic performance meets High Design
CEILING SYSTEMS [Between us, ideas become reality.] CI/SfB (35) Xy April 2006 ULTIMA CANOPY Data sheet Acoustic performance meets High Design ULTIMA CANOPY Installation Instructions I. GENERAL 1. Product
More informationSchlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing
Substrate, structural panel, bonded waterproofing The universal substrate for tiles Perfect covering No matter whether you work with mosaics or large format tiles, an absolutely level substrate with straight
More informationRe-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY
Insulation for Above the Deck WALL SPECIALTY PRODUCT DESCRIPTION Rmax Re-Cover Board-3 is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (polyiso) foam core bonded
More informationMineral fibreglass insulation
Isover MULTIMAX 30 Specification code: MW - EN 13162 - T5 - MU1 - WS - WL(P) - AF r 5 TeChNICaL SPeCIFICaTION Insulating slabs made of Isover fibreglass wool. The production method is based on the fibering
More informationPRODUCT SHEET 1 MIDLAND LEAD MANUFACTURERS LTD S CAST LEAD SHEET
CI/SfB (49) Mh8 Midland Lead Manufacturers Ltd Kiln Way Woodville Swadlincote Derbyshire DE11 8ED Tel: 01283 224555 Fax: 01283 550284 e-mail: sales@midlandlead.co.uk website: www.midlandlead.co.uk Agrément
More informationLow Energy Low Carbon Buildings
I n s u l a t i o n CI/Sfb (27.9) Rn7 M2 Seventh Issue March 2011 TR26 LPC/FM INSULATION FOR FLAT ROOFS WATERPROOFED WITH MECHANICALLY FIXED SINGLE PLY WATERPROOFING High performance rigid thermoset insulation
More informationGlass partitions SFB 3074
Glass partitions SFB 3074 Our facade system SFB 3074 is innovative in its design. We have made a great effort to obtain an energy effective system. The future requirements regarding the economical use
More informationFERMACELL Powerpanel H 2 O for Wet & Moisture affected areas
FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas Powerpanel H 2 O is a cement based board from FERMACELL. Board Characteristics Board Thickness 12.5 mm Board Sizes 1000 x 1200 mm 50 sheets/pallet
More informationfoot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.
Skylight Installation Instructions This document provides instruction and guidelines for installation of both curb mount (CM) and self flashing (SF) unit skylights on flat, pitched (> or equal to 3/12
More informationProduct Data Sheet ROCKPANEL Rockclad
Product Data Sheet ROCKPANEL Rockclad Durable - Xtreme - FS-Xtra United Kingdom 1 Product description ROCKPANEL boards are prefabricated compressed mineral wool boards with synthetic binders. The surface
More informationCHESTERFLEX ROOF WATERPROOFING MEMBRANES
CI/SfB (47) Ln2 Chesterfelt Ltd CHESTERFLEX ROOF WATERPROOFING MEMBRANES Certificate No 94/3062 DETAIL SHEET 2 Product THIS DETAIL SHEET RELATES TO CHESTERFLEX ROOF WATERPROOFING MEMBRANES, POLYESTER REINFORCED
More informationCOMMERCIAL BUILDING APPLICATIONS
EXPANDED POLYSTYRENE FOR COMMERCIAL BUILDING APPLICATIONS www.falconfoam.com Commercial Building Ap Expanded Polystyrene Insulation Falcon Foam leads the commercial building industry with products that
More informationCLEAR-DIVISIONS CENTERFOLD
CLEAR-DIVISIONS CENTERFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS CENTERFOLD moveable The yellow highlighted areas in
More informationFaçade panels for interior cladding on a wooden supporting structure
1 General These application instructions are specifically intended for the fastening of EURO PANELS OVERSEAS N.V. façade panels as decorative interior wall cladding on a wooden supporting structure. A
More informationPROFILED METAL ROOFING DESIGN GUIDE
MCRMA Technical Paper No. 6 CI/SfB (23) Nh2 JUNE 2004 PROFILED METAL ROOFING DESIGN GUIDE THE METAL CLADDING & ROOFING MANUFACTURERS ASSOCIATION LIMITED Contents Page 1.0 Typical construction and assemblies
More information0845 0098 980 www.nicholsonsts.com
0845 0098 980 www.nicholsonsts.com ROOFTRAK The IFP is revolutionising the way we fix things to roofs. Technical Director of a leading UK roofing system manufacturer The ROOFTRAK-IFP A revolutionary solution
More informationCable ladder installation at S.C.M. Chemicals Limited s titanium dioxide Plant in Western Australia
Exel Composites Cable Support Systems offer engineers a structural product for solving many design and plant engineering problems, enabling long term reliable support of expensive and often critical cables.
More informationSTENCA PIPE. High quality pipe insulation. www.stenca.com
STENCA PIPE High quality pipe insulation WELCOME TO STENCA TRADING - Global focus with local service Stenca Trading offers optimal solutions for the offshore, marine, refineries and cogeneration industry.
More informationFire Resistant Systems
Fire Resistant Systems A R C H I T E C T U R A L A L U M I N I U M G L A Z I N G S Y S T E M S Fire Resistant Systems Introduction Kawneer are pleased to introduce two new comprehensive Fire Resistant
More informationProRox Slabs (formerly known as RW slabs)
Slabs (formerly known as RW slabs) Versatile thermal acoustic insulation slabs ROCKWOOL's Slabs are high quality resin bonded slabs that can be used for thermal, acoustic and fire insulation. They are
More informationBuilt to Last. Built for Beauty. Good. Solid. Logix. TM
Built to Last. Built for Beauty. Good. Solid. Logix. TM Quality, Value and Service Introducing LOGIX Insulated Concrete Forms. Based on the simple concept of interlocking blocks, LOGIX ICF gives you a
More informationColonnade Security Pipe
Description: Round & Square downpipe formed from extruded 6060 T4 aluminium in various sizes (Ø83mm, Ø108mm, 83x83 mm & 108x108mm*) & supplied with a complete range of accessories i.e. Offsets, bends,
More informationInstallation Detailed installation instructions are provided which should be strictly followed.
Specification System 6 The Metal Technology Thermally-Broken Vertical Slide Window has been designed in such a way that its'attractive and clean lines will enhance all types of residential and commercial
More informationDubai Municipality Standard DMS 1: Part 5: 2004
Specification for precast concrete blocks Part 5: Normal-weight concrete-polystyrene sandwich masonry blocks Issue Date Revision Revision Description Prepared by Approved by Authorized by 19/12/2004 Issue
More informationConfort 26. Sliding Systems. Sapa Building System
Confort 26 Sliding Systems Sapa Building System Confort 26 is Sapa s thermally insulated sliding system for windows and doors. Available as two- and three-rail solution. Among its features, there are
More informationI-Line - Snap-On Feature
Oct 2012 I-Line - Snap-On Feature DATA SHEET Snap-On features - Guaranteed truelines every time Bailey I-Line Snap-On is an architectural cladding feature offering creative possibilities for architects
More informationMemtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems
Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology Modern Efficient Performance Cost Effective Flat Roofing Systems Introduction A complete range of Memtec Roofing and Waterproofing Single
More informationROXUL Board Insulation Section 07 21 13 Master Guide Specification (CAVITYROCK ) Page 1 April 2016
Master Guide Specification (CAVITYROCK ) Page 1 Click on the pilcrow in the MS Word Toolbar to toggle ROXUL GUIDE NOTES on and off. Delete this text before incorporating the section into a Project Manual.
More informationAsphalt Shingle Application Requirements
Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt
More informationRHEPANOL RHEPANOL FK ROOF COVERING SYSTEM
Flachdach Technologie GmbH & Co KG Eisenbahnstrasse 6 8 68199 Mannheim Germany Tel: 00 49 621 8504-372 Fax: 00 49 621 8504-378 e-mail: export@fdt.de website: www.fdt.de APPROVAL INSPECTION TESTING CERTIFICATION
More informationSmooth & Seamless Hygienic Doors for the Food Sector
CI/SfB (31.5) Xn (U46) 12/05 Smooth & Seamless Hygienic Doors for the Food Sector Applications: Food Processing Factories Bakeries Supermarkets Dairies Abattoirs Kitchen/Catering Facilities Breweries Bacteria
More informationPROPOSED SPECIFICATION FOR ALUCOBOND PLUS Aluminium Composite Panel Cladding System Fixed Watertight Cassette Panel System - 4mm thick
1. SCOPE OF WORK The scope of work includes the design, supply fabrication and installation of Alucobond PLUS aluminium composite panel cladding, complete with all necessary sub-structures, anchors, hardware
More informationIsover HVAC Application Handbook Installing fire protection insulation to metal ductwork
Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork HVAC - Fire protection of metal ductwork Fire protection Thermal insulation Isover ULTIMATE TM Protect - Fire protection
More informationBasements. I n s u l a t i o n. Low Energy Low Carbon Buildings
I n s u l a t i o n CI/Sfb (13.9) Rn7 M2 Third Issue March 2011 INSULATION FOR BASEMENTS Basements High performance rigid extruded polystyrene insulation thermal conductivities as low as 0.029 W/m.K High
More informationConfort 160. Sliding Systems. Sapa Building System
Confort 160 Sliding Systems Sapa Building System Confort 160 is a high performance thermally insulated sliding window system, with a user-friendly slide action. The system, which has an attractive aesthetic
More informationINNOVATIONS. Economic Flat Roof Refurbishment with NOVOPROOF Sealing Systems. A Company of the SAARGUMMI Group
INNOVATIONS Economic Flat Roof Refurbishment with NOVOPROOF Sealing Systems A Company of the SAARGUMMI Group OUR SOLUTION TO REFURBISH ROOFS FOR LONG-TERM DURABILITY Quality and Experience from the Innovation
More informationLight-Weight Panels. High quality panels. www.stenca.com
Light-Weight Panels High quality panels WELCOME TO STENCA TRADING - Global focus with local service Stenca Trading offers optimal solutions for the offshore, marine, refineries and cogeneration industry.
More informationTR31. I n s u l a t i o n. Low Energy Low Carbon Buildings
I n s u l a t i o n CI/Sfb (27.9) Rn7 M2 Sixth Issue March 2011 TR31 STRUCTURAL INSULATION / FSC CERTIFIED PLYWOOD COMPOSITE FOR FLAT ROOFS WATERPROOFED WITH PARTIALLY BONDED BUILT UP FELT High performance
More informationSECTION 08 5656 GUARDA SECURITY WINDOW SCREENS
Page 1 of 5 SECTION 08 5656 GUARDA SECURITY WINDOW SCREENS Guarda Security Window Screens in this specification are appropriate for use in windows, storefronts, curtain walls, vents, and any other applications
More informationCONTRACT SPECIFICATIONS - SEISMIC ISOLATION BEARINGS
CONTRACT SPECIFICATIONS - SEISMIC ISOLATION BEARINGS 1.0 DESIGN 1.1 Scope of Work 1.1.1 This work shall consist of furnishing Isolation Bearings and installing Isolation Bearing Assemblies at the locations
More informationHanson Building Products. precast basement solutions
Hanson Building Products precast basement solutions Hanson Building Products Basement Systems Add an extra dimension and combine the inherent flexible, structural and waterproof properties of concrete
More informationTABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"
2 TABLE OF CONTENTS SECTION 1: What is a Standing Seam Metal Roof PAGE 3 SECTION 2: Common Types of Standing Seam Metal Roofs..PAGE 5 SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE
More informationCLEAR-DIVISIONS APERTO
CLEAR-DIVISIONS Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS moveable glass wall system. The yellow highlighted areas in the
More informationCLEAR-DIVISIONS VARIOFOLD
CLEAR-DIVISIONS VARIOFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS VARIOFOLD moveable The yellow highlighted areas in the
More informationInstallation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: 1996. No.: SE-...
Installation guide for the SafeLine type anchorage device Tested in compliance with EN 795: 1996 No.: SE-... Version: 09.10.2008 SE 67 Subject to technical alterations! Contents 1. General information
More informationRemovable Insulation Blankets from A to Z
Removable Insulation Blankets from A to Z At first glance, making up a removable insulation blanket seems somewhat simple take some insulation, put some mesh on one side, a cover on the other, sew them
More informationSECTION 07560 FLUID APPLIED ROOFING (LIGHT TRAFFIC DECKS OVER CONCRETE)
SECTION 07560 FLUID APPLIED ROOFING (LIGHT TRAFFIC DECKS OVER CONCRETE) PART 1 GENERAL 1.1 DESCRIPTION 1. Fluid applied flexible acrylic waterproofing system over concrete. This work shall include the
More informationBAUDER BITUMINOUS ROOFING SYSTEMS BAUDERFLEX ROOF WATERPROOFING SYSTEMS
Bauder Ltd 70 Landseer Road Ipswich Suffolk IP3 0DH Tel: 01473 257671 Fax 01473 230761 e-mail: mail@bauder.co.uk website: www.bauder.co.uk APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL APPROVALS
More informationMULTI ROOFING. Our Services. www.multiroofing.ie www.multiroofing.co.uk
Our Services www.multiroofing.ie About Us MultiRoofing Systems Ltd was established in 1992 to meet the needs of a growing construction industry in Ireland. Through organic sustainable growth, MultiRoofing
More informationENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES
ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES PART 1 - GENERAL 1.1 SCOPE OF WORK SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED SQUARE TUBE LADDER
More informationEnergy Company Obligation (ECO): Technical Monitoring Questions
Energy Company Obligation (ECO) Technical Monitoring Questions v1 30/05/2013 Energy Company Obligation (ECO): Technical Monitoring Questions Under ECO suppliers are required to instruct suitably qualified
More informationStorage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.
Installation Guide Before you begin, take the time to read this entire guide to clearly understand the requirements and steps to follow for proper installation. Warning Do not install defective material.
More informationSeries 456 Commercial Awning Window
Commercial Awning Window COMMERCIAL SERIES Photo courtesy of Hanlon Windows Australia DATE: MAY 2013 REPLACES: MARCH 2008 COMMERCIAL SERIES KEY FEATURES/PERFORMANCE CHARACTERISTICS Scale: not to scale
More informationPreformed Metal Roofing and Siding
Page -1-1. GENERAL 1.1. Description This specification along with the drawings covers the furnishing of all material, products, equipment, accessories, tools, services, transportation, labor and supervision
More informationThe better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs
The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs February 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements...................................
More informationCERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED
CERTIFICATE OF APPROVAL No CF 291 This is to certify that, in accordance with TS General Requirements for Certification of Fire Protection Products The undermentioned products of Drummond Road, Stafford.
More informationHoesch Matrix System individuell. ThyssenKrupp Steel Europe Thinking the future of steel
Hoesch Matrix System individuell ThyssenKrupp Steel Europe Thinking the future of steel 2 3 Steel in perfect shape and precision Steel the material of contemporary architecture. Throughout the production
More informationBafl-Sorb Sound Absorbing Ceiling Baffles
Bafl-Sorb Sound Absorbing Ceiling Baffles INC offers a complete line of Sound Absorbing Ceiling Baffles to compliment any environment. Our ceiling baffles are among the most cost-effective method of adding
More informationRead and understand all installation instructions and precautions before installing. GENERAL APPLICATION INSTRUCTIONS
AC TOPSEAL SELF-ADHERED, GRANULAR SURFACED, SINGLE PLY, LOW SLOPE ROLLED ROOFING 3 X 33.3 = 100 SQ. FT. 10 YEAR MATERIAL LIMITED WARRANTY For Use on Porches / Sheds / Utility Buildings / Accessory Buildings
More informationTimber Frame Walls Rethinking Construction
Insulation Fifth Issue November 2007 Timber Frame Walls Rethinking Construction INSULATION BEST PRACTICE FOR THE 21ST CENTURY Summary 9 mm OSB sheathing 3 mm skim coated 15 mm plasterboard Rock or glass
More informationBuilding to the Power of
Insulated Panels CI/SfB (4-) Rh2 UK September 2008 Insulated Standing Seam Roof System Approved to LPS 1181 : 2003 Certificate No s. 260a/24 & 186a/24 Building to the Power of Insulation Built-in Introduction
More informationA D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, 2012. All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA
Page 1 of 10, Addendum No. 3 Temporary Garage Structure City of Chelsea, MA November 5, 2012 CBI Job No.: 12055-A A D D E N D U M # 3 DATE: November 5, 2012 TO: FROM: PROJECT: All Bidders Jenne dos Santos,
More informationHow To Make An Oriented Strand Board
ABOUT COMPANY Mission Provide solutions to enchance customers product value. Vision - To be a leader among wood based panel producers in the region. Values Innovation, integrity and team commitment. BOLDERAJA
More informationfr fire retardant MARMOLEUM
MARMOLEUM fr fire retardant MARMOLEUM fr 63038 63173 63174 sahara van gogh caribbean 63120 63163 63164 indian summer opera rosato 63182 63055 63030 blue fresco blue lapponia 63032 63146 63048 graphite
More informationConcepts. Products. Service. Lindner Plus Organisation
Concepts Products Service Lindner Plus Organisation Building new solutions. Lindner undertakes major worldwide projects in all areas of interior finishes, insulation technology, industrial services and
More informationEnclosures 1-866-338-0988. DuraSystems Barriers, Inc. www.durasystems.com Email: sales@durasystems.com. The Passive Fire Protection Specialists
Enclosures Sturdy single and double wall fire protection construction Impact resistant Fast & easy installation Pre-manufactured and modular Available in galvanized, stainless steel & other specialty metals
More informationKALZIP STANDING SEAM ROOF SYSTEMS KALZIP DECK ROOF SYSTEM
Kalzip Ltd Haydock Lane Haydock St Helens Merseyside WA11 9TY Tel: 01942 295500 Fax: 01942 295508 e-mail: enquiries.uk@kalzip.com website: www.kalzip.com APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL
More informationRockwool Flexi Insulation Application Guide
Pitched roof Rafters InterMediate floors INTERNAL partitions external Framed walls separating floors Separating Walls Rockwool Flexi Insulation Application Guide Ground floor The perfect fit for any framed
More informationHow To Certify The Scottsdale Construction System
BRE CERTIFICATION LIMITED PRODUCT SCOTTSDALE CONSTRUCTION SYSTEM CERTIFICATE NUMBER 129/07 DATE OF ISSUE December 2007 SUPPLIED BY Scottsdale Construction System Ltd SUMMARY The Scottsdale Construction
More informationAthena is the name given to our assortment of electronic tapes. products of the very highest quality. These tapes both conduct and
Electric Athena. Athena is the name given to our assortment of electronic tapes products of the very highest quality. These tapes both conduct and insulate against electricity, in addition to warmth and
More informationProduct Guide Specification
Stabilit America, Inc., dba Glasteel June 2005 285 Industrial Drive Moscow, Tennessee 38057 Toll Free (800) 238-5546 Phone (901) 877-3010 Fax (901) 877-1388 Web Site www.glasteel.com Product Guide Specification
More informationKINGSPAN INSULATION KINGSPAN KOOLTHERM K12 FRAMING BOARD INSULATION
Kingspan Insulation Limited Pembridge Leominster Herefordshire HR6 9LA Tel: 01544 388601 Fax: 01544 388888 e-mail: general.enquiries@kil.kingspan.co.uk APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL
More information