1 72 MY HOME Burglar alarm
2 CONTENTS. MY HOME Burglar alarm General features. 74 General rules for installation. 87 Configuration 203 Start-up and testing. 26 Burglar alarm MY HOME 73
3 GEnEral features Professional safety the MY HOME burglar-alarm system is a safe and effective alarm system for the protection of people and their belongings, capable of detecting any intrusions, promptly notifying the event by means of sound and visual alarms, and by sending telephone messages the system includes a central unit that can be programmed for control and supervision of the system, management and control devices, volumetric sensors (ir technology or dual ir+mw technology), for the internal protection of the house, and perimeter sensors for the protection of doors and windows By integrating special devices, the system can also perform "safety" functions, such as remote assistance for old people, and the protection of the house from gas or water leaks as for all the MY HOME system, the wiring of the of the burglar-alarm system is based on BuS technology all the devices are therefore connected using a non-polarised 2 wire cable this features allows to share information with the other MY HOME BuS functions, and obtain advanced applications WIDE RANGE OF SOLUTIONS Central unit with integrated PStn or GSM communicator, managing up to 72 sensors in 8 areas transponder connectors, radio wave connectors, infrared and numeric code connectors Wired or radio devices technical alarm management ademco Contact id communication protocol management RADIO EXPANSION By integrating the radio interface with the BuS system it is possible to expand the burglar-alarm system with radio detection and control devices a range of optional functions also become available: technical alarms - using a specific sensor, it is possible to perform flood control of the room remote assistance - to assure peace of mind and prompt assistance for people in difficulties radio control it is also possible to integrate a radio remote control, for radio arming and disarming Outdoor siren Central unit with PSTN or gsm communicator Power supply 230 Vac BuS IR+MW sensor IR sensor Basic contact interface Magnetic contacts 74 MY HOME Burglar alarm
4 INTEGRATION WITH OTHER MY HOME SYSTEMS using a special interface, the burglaralarm system can be easily integrated with other MY HOME systems, to obtain the following: advanced applications resulting from the synergy among the individual systems (for example automatic switch-on of the lights following a burglar-alarm event); local central management or remote central management via the internet, using the MY HOME WEB portal of the system RADIO DEVICES Remote control Radio perimeter detector BuS MY HOME SYSTEM Automation Video door entry system IMQ ALARM CERTIFICATION FOR LEvEL 2 DEvICES the Bticino burglaralarm system offers solutions for each protection requirement: from the minimum protection limit required in an apartment, to the most stringent levels offered by professional systems Radio volumetric presence detector Central management Keypad connector with display Radio receiver SCS/SCS interface BuS To any other systems Key ring badge transponder Badge transponder Transponder connector Keypad connector Burglar alarm MY HOME 75
5 GEnEral features advanced functions: the safety of the home and of people the burglar-alarm system WATER OR GAS LEAK ALARM REMOTE ASSISTANCE represents the basic infrastructure Water or gas leak detection with Forwarding of assistance request by for alarm management, but the message forwarding and immediate calling personal numbers. set of applications which can shut-off of the water or gas piping. Old, disabled or recovering people be implemented can easily be By integrating a water or gas sensor may send an assistance request expanded in fact the burglar-alarm with the burglar-alarm system, using a portable remote control system can be used to ensure the in case of such a danger event the signal transmitted is detected protection of people and their occurring, the burglar-alarm system by a radio receiver connected to the belonging from dangerous events activates a solenoid valve that orders burglar-alarm system, which activates such as gas leaks, flooding, etc with the shutting-off of the water or gas an indoor siren, and the telephone alarm notifications (also remotely distribution network at the same communicator of the central unit, through telephone messages) time an indoor siren will be activated, which forwards the assistance Below are some examples: while a burglar-alarm central unit request to the set number(s) communicator will forward a telephone alarm message WATER OR gas LEAK ALARM TV/SAT REMOTE ASSISTANCE IPTV TV/SAT Indoor siren automazione diffusione sonora antifurto termoregolazione videocitofonia automazione controllo diffusione sonora lan controllo antifurto carichi termoregolazione energia videocitofonia luci controllotv Indoor siren (optional) Relay actuator Radio receiver Radio receiver Flooding detector Radio control for remote assistance 76 MY HOME Burglar alarm
6 PANIC ALARM ANTI-BURGLARY ALARM in case of suspected noises inside in case of danger, it is possible to the home, the owner can manually activate the burglar-alarm system activate the burglar-alarm system for sending a remote assistance to generate an alarm signal if the request through the central unit system is armed all the sirens will communicator the activation does activate to confuse any intruders not generate a sound alarm, thus at the same time, the telephone allowing the police force to surprise communicator of the central unit will the burglar, who is not aware that the also send a remote assistance request call has been made if the system is not armed only the indoor siren will activate (if present), while the communicator will forward the request for assistance ANTI-BuRgLARY ALARM TV/SAT Indoor siren (optional) IPTV PANIC ALARM Technical alarm interface TV/SAT Technical alarm interface IPTV automazione diffusione sonora antifurto termoregolazione videocitofonia controllo lan controllo carichi energia luci tvcc automazione diffusione sonora antifurto termoregolazione videocitofonia controllo lan controllo carichi energia N.C. pushbutton N.C. pushbutton STOP & GO: TELEPHONE SIGNALLING OF TRIPPING OF THE GENERAL CIRCUIT BREAKER By connecting SalVaVita StOP&GO to the burglar-alarm system using a special interface, it is possible to receive a telephone message in case of tripping of the circuit breaker due to storm, electric disturbance, or system fault the SalVaVita StOP&GO device automatically closes the tripped circuit breaker, reinstating the power supply in fully safe conditions However, if the fault remains, due to an insulation defect or line overload, the burglar-alarm system will no longer try to reinstate the power supply, but will forward a message Stop & go circuit breaker STOP & go Technical alarm interface TV/SAT Control interface IPTV diffusione sonora antifurto termoregolazione videocitofonia controllo lan controllo carichi energia luci tvcc www Burglar alarm MY HOME 77
7 GEnEral features advanced functions: integration with other MY HOME functions By sharing the same means of information transmission (BuS pair), the MY HOME applications can be easily integrated with each other to optimise functions and to generate new ones, thus meeting new requirements in this respect, the Burglar-alarm system can be easily integrated with the automation or Video door entry system using a special interface f422 Of course by using several interfaces it will be possible to create fairly complex systems, through the integration of the burglar-alarm system with other systems with different functions (sound system, temperature control, etc ), which can therefore be managed also using a remote PC and the internet Below are some examples: By integrating the burglar-alarm system to the automation system it is possible to automatically switch on all the lights of the home following an intrusion event automatic disabling of the heating system By integrating the burglar-alarm system with the heating system, it is possible to set a particularly useful function, which can bring in important energy savings, by avoiding unwanted dispersion of heat to the outside, for example when changing the air inside the house in practice, when the doors or windows of a room are opened, the heating system of the temperature control zone of that room is automatically turned off the opening and closing of doors and windows is detected by the burglar-alarm system contact interface, which reads the status of the nc contact installed on the door or window, and sends the information to the temperature control system for the appropriate actions COuRTESY LIgHTS MANAgEMENT TV/SAT AuTOMATIC DISABLINg OF THE HEATINg IPTV SYSTEM Magnetic contact Interface diffusione sonora antifurto termoregolazione videocitofonia controllo lan controllo carichi energia luci tvcc www irrigazione TV/SAT IPTV Opening of TV/SAT window IPTV Interface automazione diffusione sonora antifurto termoregolazione videocitofonia controllo lan controllo carichi energia automazione diffusione sonora antifurto termoregolazione videocitofonia controllo lan controllo carichi energia luci tvcc general light control TV/SAT IPTV Control interface automazione diffusione sonora antifurto termoregolazione videocitofonia controllo lan controllo carichi energia luci 78 MY HOME Burglar alarm
8 System devices the pages that follow show the main devices making up the MY HOME burglar alarm system for the full list, refer to the Catalogue section BURGLAR-ALARM CENTRAL UNIT available in two versions: With telephone communicator, PStn or PStn/GSM; Without telephone communicator this is the device at the heart of the burglar-alarm system, capable of managing up to 72 sensors in 8 areas, and recognise up to 50 keys for the arming/disarming of the system using the large display, the user can control the system status, set advanced operating modes, such as user customisation, scenario management and activation of advanced functions resulting from the integration with other MY HOME systems it's also preset for the ademco Contact id function, for forwarding telephone messages to vigilance bodies following a burglar-alarm or technical alarm event Customisation of users the central unit can be programmed to allow access inside the house based on two criteria that can be customised by the user; by time band, and by type of area time band: access in protected areas is only allowed at certain times for example, the maid is given a key that disables the burglar-alarm system each tuesday between 9 00 o'clock and 2 00 o'clock area: access inside the house is only permitted in some areas for example, the gardener is given a key that only gives him access to the tool room Central unit with PSTN or gsm telephone communicator Managing scenarios it is possible to define up to 6 scenarios to activate, with one single operation, the burglar-alarm system for the areas of the home that need protecting it is also possible to associate a certain scenario to each individual key Protected areas System state Base central unit Night scenario: total protection of the day area and perimeter protection of the house. Work scenario: complete protection of the house. LEgEND Perimeter protection Day area IR protection Night area IR protection Burglar alarm MY HOME 79
9 GEnEral features Control and protection devices ACTIvATORS these devices can be used to arm/ disarm the system by entering a numeric code or using a transponder key using the keypad connector with display it is also possible to select the areas of the house that need protecting (separation), and to know the system status through the information shown on the display Transponder key reader Keypad connector with display CONTACT INTERFACES for the connection to the burglaralarm system of normally closed (nc) or normally open (no) magnetic contacts for the protection of doors and windows Radio remote control with built-in transformer DIN contact interface BASIC contact interface IR SENSOR for the protection of the areas of the house available in two versions: With ir sensor With ir sensor and MW (microwave) sensor for the protection of doors and windows, ir barriers are also available, in lengths between 0 5 and 2 metres IR barriers IR+MW sensor Note: For the full list of all the available devices refer to the Catalogue section. 80 MY HOME Burglar alarm
10 Devices for radio expansion and technical alarms IR SENSOR AND RADIO MAGNETIC CONTACT Battery powered, these devices can be used to protect rooms where no BUS wiring is present. Window-breaking radio detectors Radio IR sensor WIRE-RADIO INTERFACE It allows integration with the wired burglar-alarm system of radio technology devices, such as the radio remote control in the previous page, and the devices listed below. Wire-radio interface DEVICES FOR TECHNICAL ALARMS This family includes devices such as: The radio control, to send an assistance request; The radio sensor, to detect the presence of water; The Auxiliary channel interface, for integrating gas and water sensors with the burglar-alarm system; The Basic module contact interface. Radio water sensor Radio control for Remote assistance Burglar alarm MY HOME 8
11 GEnEral features System selection criteria today the wire burglar-alarm system can satisfy any installation needs in the home the criteria should thus be indicated for a correct choice of the components, depending on the type of structure to be made safe and the functions required four factors are to be considered when choosing a system area to be protected alarm modes Protections System control AREA TO be PROTECTED AVAILAbLE FUNCTIONS base CENTRAL UNIT CENTRAL UNIT WITH PSTN COMMUNICATOR CENTRAL UNIT WITH PSTN/ gsm COMMUNICATOR L/N/NT4600/4 Polyx Alarm 3485B HC/HD/HS460 L/N/NT460 Polyx Alarm Maximum number of sensors Maximum division into zones (areas) SYSTEM CONTROL WITH RADIO REMOTE CONTROL WITH IR REMOTE CONTROL (ONLY WITH CENTRAL UNIT L/N/NT4600/4 AND 3486) WITH TRANSPONDER WITH NUMERIC CODE HC/HD/HS/L/N/ NT468 Radio receiver HC/HD/HS4604, L/N/ NT4604 Activator HC/HD/HS4607, L/N/ NT4607, AM5787 Transponder reader HC/HD/HS4606, L/N/ NT4606, AM5786 Keypad connector Radio remote control HC/HD/HS4603/4 L/N/NT4603/4 IR divider HC/HD/HS4607/4 L/N/NT4607/4 AM5787/4 Divider transponder 4050 Remote control 3530S, 3540 Badge, key-ring HC/HD/HS4608 L/N/NT4608 Keypad connector with display 82 MY HOME Burglar alarm
12 PROTECTIONS AREA CONTROL PERIMETER CONTROL Fixed sensitivity Variable sensitivity Sensors + Barriers Detectors 350 FLUSH mounted magnetic detector Swivel IR (distance 6 m) L/N/NT46B AM579B Fixed IR (distance 3 9m) HC/HD/HS460 L/N/NT460 AM Visibly magnetic detector 356 Window breaking detectors 354 Cable detector for shutters 353 Magnetic detector for metal main doors Wall mounting IR (distance 6 m) N4640B Wall mounting IR (distance 3 9 m) N4640 Wall mounting IR (distance 4 2 m) Magnetic detector for swing doors 3444 Window-breaking radio detectors 3445 Cable radio detector for rolling shutters 350M Brass FLUSH mounted magnetic detector Dual-technology (distance 0 m) HC/HD/HS463 L/N/NT463 Swivel IR (distance 3 9 m) HC/HD/HS46 L/N/NT46 AM579 Brass FLUSH mounted magnetic detector 350PB 358, 358/50, 358/50, 359 IR barriers for windows 3442 Radio opening detector Burglar alarm MY HOME 83
13 GEnEral features System selection criteria ALARM MODES OPTION back-up battery in the outdoor siren Option2 - back-up battery in the switchboard POWER SUPPLY OUTDOOR SIREN INDOOR SIREN POWER SUPPLY OUTDOOR SIREN INDOOR SIREN E46ADCN 4072L HC/HD/HS/ N/NT4070 E47ADCN 4072A HC/HD/HS/ N/NT4070 Only outdoor siren Outdoor and Indoor siren Only indoor siren Central unit with communicator No siren 3486 Polyx Alarm 3485 Warning: if both internal and external sirens are installed, tampering with the system when disarmed will only cause the indoor siren to go off. ACTIVATION OF THE ALARM DEVICES DEPENDINg ON THE STATUS OF THE SYSTEM AND THE DANgER EVENT SYSTEM ARMED Alarm event Indoor siren Outdoor siren 4072A (without internal back-up battery) Outdoor siren 4072L (with internal back-up battery) Relay actuator 3479 and F48 () Telephone communicator of the 3485 and 3486 central units Internal relay of the 3485B and L/N/NT460 central units (2) Burglar Rings Rings Rings Activates Calls Activates Tamper Rings Rings Rings Activates Calls Activates Tamptest Rings Rings Rings Activates Calls Activates Anti-panic Rings Rings Rings Activates Calls Activates Silence (burglar alarm) Does not ring Does not ring Does not ring Does not activate Calls Does not activate Note (): configure the device in MOD=0 (siren status repetition) to enable the operation described in the table. Note (2): The relay contacts can be used to connect a third party optical/luminous alarm diffuser, or a telephone communicator. 84 MY HOME Burglar alarm
14 SYSTEM DISARMED Alarm event Indoor siren Outdoor siren 4072A (without internal back-up battery) Outdoor siren 4072L (with internal back-up battery) Relay actuator 3479 and F48 () Telephone communicator of the 3485 and 3486 central units Internal relay of the 3485B and L/N/NT460 central units (2) Tamper Rings Does not ring Does not ring Activates Forwarding of event notification message Activates Tamptest Does not ring Notification Does not ring Notification Does not ring Notification Does not activate Forwarding of event notification message Does not activate in central units with display, or LED notification in central unit L/N/NT460 in central units with display, or LED notification in central unit L/N/NT460 in central units with display, or LED notification in central unit L/N/NT460 Tampering (disconnection of the central unit from the system) Rings Does not ring Does not ring Activates Forwarding of event notification message Activates Tampering (disconnection of the siren from the system) Rings Rings Does not ring Does not activate Forwarding of event notification message Does not activate Anti-panic Rings Does not ring Does not ring Activates Forwarding of assistance request message Activates Silence (burglar alarm) Does not ring It rings if the L/N/NT4600/4 central unit is installed Does not ring It rings if the L/N/NT4600/4 central unit is installed Does not ring It rings if the L/N/NT4600/4 central unit is installed Does not activate Forwarding of assistance request message Does not activate Note (): configure the device in MOD=0 (siren status repetition) to enable the operation described in the table. Note (2): The relay contacts can be used to connect a third party optical/luminous alarm diffuser, or a telephone communicator. Burglar alarm MY HOME 85
15 GEnEral features System selection criteria CENTRAL UNIT FUNCTION in addition to the criteria explained in the previous pages, the selection of the central unit can be made taking into account the possible available functions, such as: KEYS ONLY OPERATING DURING CERTAIN TIME BANDS Enabling for the cleaning staff in order to be able to do her job, the maid has been given a key for the disarming of the burglar-alarm system across the whole house, but only between 9 00 o clock and 2 00 o clock, on normal working days During all other times and holidays the key does not operate AUTOMATION WITH CENTRAL UNIT 3486 OR Switching on of all home lights. if the burglaralarm system is integrated with the automation system, it can be set in such a way that if burglar-alarm event occurs, some or all the lights of the house will come on, inducing the burglar to leave KEYS ONLY OPERATING IN CERTAIN AREAS. Enabling access for the gardener. the cellar is used to store gardening tools and is made accessible by the owner of the house every tuesday from 2 00 to 6 00 pm in order to do his job, the gardener has been entrusted with a key, which during the above times deactivates the burglar-alarm system of the cellar all other areas of the house are still protected by the burglar-alarm system, armed by the owner when leaving the home for work AUTOMATION WITH CENTRAL UNIT 3485B. Activation of division scenario. Each time the key is used (transponder, radio remote control or numeric key) to activate the system, a specific division scenario will be activated CENTRAL UNIT FUNCTION AVAILAbLE FUNCTIONS 4 ZONE FLUSH-MOUNTED CENTRAL UNIT CENTRAL UNIT WITH PSTN COMMUNICATOR CENTRAL UNIT WITH PSTN/ gsm COMMUNICATOR L/N/NT4600/4 Max. no. of keys that can be saved () Key constraints (day/ zone/time) (2) Polyx Alarm 3485B HC/HD/HS460 L/N/NT460 Polyx Alarm NO NO SI SI 3486 Max. no. of scenarios NO Max. no. of automations NO 0 (see note 4) 20 (see note 3) 20 (see note 3) PC programming with software NO TiSecurity Basic for firmware update TiSecurity POLYX for the programming of parameters and firmware update TiSecurity GSM for the programming of parameters and firmware update NOTE: () Keys are any control devices such as IR remote control, radio remote control, transponder key, and numeric key. (2) Each key can be set to only operate certain days of the week, in certain areas, or during certain time bands. (3) If the system is integrated with other MY HOME systems, for example lights automation, it is possible to switch all the lights of the house on, if a burglar-alarm system event occurs. (4) Of the 0 possible automations, one is activated using an auxiliary relay inside the central unit. The other 9 are combined to Arming, disarming, Date and Time events. 86 MY HOME Burglar alarm
16 GENERAL RULES FOR INSTALLATION Project approach The project of setting up a new MY HOME BURGLAR-ALARM system can be completed in two ways: Functional this is a good compromise between cost and safety. The main priority is selecting which functions to include, and the possibility of making the system ready for future expansion is also taken into account. This solution includes, for example, both volumetric and perimeter protection. Advantages: high level of flexibility and increase in the value of the property. Economical based on an economic, low cost installation It does not exclude the use of the different features offered by the system, although it only calls for the use of one type of protection (volumetric), and does not take into account future system expansions. Advantages: low cost installation. In order to ensure a good work setup, the following elements are needed: Planimetry (absolutely necessary), of the living unit, so that the locations where the system elements are to be installed can be defined beforehand. It would also be appropriate to have a furniture plan. Definition of the protections, necessary to define which system devices to include (volumetric, perimeter or combined protection), and check that the protecting devices actually cover the appropriate areas. ESSENTIAL ELEMENTS Once the above information is available, the following must be agreed: Selection of the protection: Volumetric protection is normally the basic protection. This decision must be made taking into account various aspects, with the main one being the actual location of the property. For properties on the ground or st floor, perimeter protection and/or protection of the rolling shutters, is recommended. Perimeter protection is also recommended if external access points near balconies are also present (e.g. rain water pipes, gutters, nearby balconies or terraces). With perimeter protection, the system can also be armed when people or animals are inside the property. Example of house split into 4 zones Zone 4 - bedroom Zone 2 - kitchen Division into zones For a better management of the sensors needed to protect the property, it is recommended that the system is divided in at least 2 ZONES: a perimeter and a volumetric zone (up to 9 sensors per zone) In properties with more than 2 rooms, the system should be divided into at least 4 ZONES: 2 Perimeter ZONES (day/night areas) 2 Volumetric ZONES (day/night areas) In properties with several rooms, or in villas, the system should be divided into 4 ZONES or more. If the system does not include an external burglar-alarm arming / disarming device, a time delay should fitted on the sensors protecting the main entry. Otherwise, the entrance area should be kept as part ZONE, on which a time delay can be set as standard. Zone 3 - living room Zone - entrance Burglar alarm MY HOME 87
17 - General rules for installation System measurement MAXIMUM REACHABLE DISTANCES The maximum number of devices that can be connected to the BUS depends on the total absorption of the same and the distance between the point of connection and the power supply. The power supply can supply up to.2 A (E46ADCN) or A (E47ADCN); the maximum number of devices will therefore be determined by the sum of the absorptions of the individual devices to be installed. In calculating the absorptions it will also be necessary to consider the availability of current based on the length of the cable. During sizing ensure that the following rules are complied with: When two outdoor sirens are installed the connection lines between siren and power supply must be separate and the maximum length of each should not be more than 00 metres, while the sum of the two should not be more than 75 metres. The maximum length of the connections between the two furthest-away devices must not be more than 75 metres. The maximum length of the connections must not be more than 350 metres MAXIMUM BUS CABLE LENGTHS A = 00 m max B = 00 m max A+ B = 75 m max A + C = 75 m max A + B + C = 350 m max + C COM C2 2V C C2 C A B Note: During this check do not consider the connection between NC (normally closed) contacts and the corresponding interface module. 88 MY HOME Burglar alarm
18 SYSTEMS WITH AND WITHOUT Outdoor siren Traditional burglar-alarm systems - which require an outdoor siren as it is equipped with the back-up battery of the whole system - can sometimes cause inconvenience to neighbours in case of an alarm, especially in condominium flats. BTicino gives you the opportunity to avoid this drawback by using a specific power supply unit instead of the power supply E46ADCN. This power supply unit can be used for connecting a back-up battery (not supplied). It is easily available and necessary to power the system in case of power failure from the mains. The battery to be used with it must have the following features: 2 V, 7,2 24 Ah. The power supply unit and the battery are installed in wall mounted enclosures F5/8A and F5/8B which guarantee protection against tampering attempts thanks to special self-protection systems. The outdoor siren is now considered optional: However, if you want to install it, use siren 4072A. Warning: in order to install the devices and assure level 2 protection according to CEI standard use wall mounted boxes fitted with tampering and tearing protection devices(to prevent units being pulled away). These boxes are also needed when installing contact interfaces F482, or batteries with sizes not compatible with switchboards F5/8A. Power supply E47ADCN TYPE OF SYSTEM WITH OUTDOOR SIREN REQUIRED Power supply E46ADCN Siren 4072L + Battery inside the siren 3505/2 WITH OUTDOOR SIREN OPTIONAL Power supply E47ADCN Siren 4072A + Battery 2 V 7.2/2/24 Ah Note: the table summarises the combinations implement based on the type of system to create. Burglar alarm MY HOME 89
19 General rules for installation System measurement CHECK ELECTRICAL CONSUMPTIONS After checking the length of the connections, it is necessary to determine the sum of the total currents absorbed by the devices installed. This verification will determine whether it is necessary to equip the system with or 2 outdoor sirens or the type of battery to use. This is necessary in order to provide the most complex system with a minimum required autonomy of 24 hours, at a temperature of 25 C in case of power failure from the mains. if you use the E46ADCN power supply unit and the absorption is less than 50mA, you will only need to install a siren 4072L; if the absorption is higher than 50mA, it will be necessary to install 2 sirens 4072L; However, the total absorption must not exceed 300mA. For both cases, a 24 hour duration is guaranteed. if you use the E47ADCN power supply unit, you will only need to install a 7.2 Ah, 2 Ah or 24 Ah battery. The following chart indicates the maximum absorption required by the system, according to the battery installed and to the level of autonomy required. However, the maximum absorption must not exceed 700 ma. The maximum consumptions of the self-powered devices have already been deducted from the maximum current that can be supplied by the power supply unit. MAXIMUM CURRENT DELIVERED TO THE DEVICES ON THE BUS WITH POWER SUPPLY E47ADCN AUTONOMY IN CASE OF LACK OF NETWORK Type of battery installed 7.2 Ah 2 Ah 24 Ah 24 h 0 ma (*) 90 ma (*) 380 ma 5 h 80 ma 300 ma 600 ma 8 h 340 ma 560 ma 700 ma (*) In this case the system complies with level 2 of the CEI 79-2 standard. MAXIMUM CURRENT DELIVERED TO 2 V DEVICES WITH POWER SUPPLY E47/2 (This power supply is used, for example, in IR barriers) AUTONOMY IN CASE OF LACK OF NETWORK Type of battery installed 7.2 Ah 2 Ah 24 Ah 24 h 300 ma (*) 500 ma (*) A 5 h 480 ma 800 ma,6 A 8 h 900 ma.5 A 2 A (*) In this case the system complies with level of the CEI 79-2 standard. Note: in order to ensure level 2 performances according to CEI 79-2 standard in case of lack of network power supply, use batteries capable of ensuring system autonomy for at least 24 hours. Tables of unit absorptions DEVICE Absorbed current 4 zone central unit 25 ma Central unit ma (stand-by) max 20 ma Central unit ma (stand-by) max 90 ma Central unit 3485B; HC/HD/HS/L/N/NT ma Activator 8 ma Transponder reader 2 ma Zone divider 4; Zone divider to 4 transponder 5 ma 5-8 zone expander 0 ma Disconnector with key 5 ma Keypad connector with display 28 ma Keypad connector 5.5 ma Fixed sensitivity IR detector; Passive IR detector; Passive IR articulated detector 4.5 ma Dual-technology detector 5 ma 35 ma ** IR barriers 50 ma Contact interface 5 ma Contact interface - 2 V 5 ma * Contact interface - 2 DIN mod. 6 ma Interface ma Relay actuator 20 ma Technical alarm interface 6 ma Radio receiver 5 ma Indoor siren 8 ma Outdoor siren 4072A 5 ma Interface F422 2 ma Note:* Plus the absorption of the detector connected to it ** Consider: - 35mA for the first detector installed; 5 ma for all the others. 90 MY HOME Burglar alarm
20 C OK 0 P Each system can be made up of a minimum and maximum number of devices as shown in the following tables. CENTRAL UNIT FOR MAX. 36 SENSORS L/N/NT4600/4, AM4600/4 HC/HD/HS/L/N/NT B Minimum No. Maximum No. Minimum No. Maximum No. Minimum No. Maximum No. KEYS IR remote control Not managed Not managed Not managed Not managed Radio remote control Transponder 0 MAX 30 in total 0 MAX 20 in total 0 Numeric code MAX 20 in total Activators and dividers Keypad connector with display Keypad connector 0 9 for each zone for each zone (total 45) (total 45) Transponder reader or Divider transponder 9 for each zone 0-4(total 45) IR activator, zone -4 divider 0 9 (in total) Not managed Not managed Not managed Not managed Disconnector with key Detectors (IR and contact interface) 9 for each zone -4 (total 36) 9 for each zone -4 (total 36) 9 for each zone -4 (total 36) Technical alarm interface and actuator relay Radio receiver 0 9 for each zone 0-4 (total 45) 0 9 for each zone 0-4 (total 45) 0 9 for each zone 0-4 (total 45) Burglar alarm MY HOME 9
21 CLEAR 2 3 General rules for installation System measurement CENTRAL UNIT FOR MAX. 72 SENSORS OK Minimum No. Maximum No. Minimum No. Maximum No. KEYS IR remote control Not managed Not managed Radio remote control Transponder 0 MAX 50 in total 0 MAX 50 in total Numeric code 0 Activators and dividers: Keypad connector with display 0 0 Keypad connector for each zone 0 8 (total 8) Transponder reader or Divider transponder for each zone 0 8 (total 8) IR activator, zone -4 divider with 5-8 expansion unit Not managed Not managed 0 9 in total Disconnector with key 0 0 Detectors (IR and contact interface) 9 for each zone 8 (total 72) 9 for each zone 8 (total 72) Technical alarm interface and actuator relay 0 9 for each zone 8 (total 72) 0 9 for each zone 8 (total 72) NUMBER OF SIRENS Indoor siren Outdoor siren Minimum No. Maximum No. Minimum No. Maximum No. E46ADCN Not managed 3 (2 if a central unit with display is installed) Not managed 2 ( 4072L) E47ADCN 0 3 () 0 2 ( 4072A) NOTE (): the total number of internal/outdoor sirens must not exceed 3. Example: 2 indoor sirens and one outdoor siren. 92 MY HOME Burglar alarm
22 Example: apartment burglar-alarm system 00 m 2 apartment on the ground floor of an apartment complex, with balcony and continuous vertical protection parapet on one side the main entry consists of a door, while all french windows can be considered as alternative accesses these access ways are all controlled by magnetic contacts in view of the position, it is recommended that volumetric detectors are installed in all rooms, thus increasing the level of safety this will also make the system easier to manage it is recommended that volumetric systems are always installed, as the intruder may be able to break through the physical barriers (rolling shutters/window glass) without actually opening the door or window in this case, the magnetic detector on the opening would in fact be unable to generate the alarm this type of setup would also give the user the possibility to customise the system to meet personal needs this gives clear advantages on a management point of view for example: perimeter protection can be used during the night; volumetric sensors can be armed, whilst leaving perimeter sensors disarmed, during short absences to ensure this flexibility, the various sensors should be grouped appropriately in this case, the system can be divided as follows: magnetic contact and volumetric detector for the living room: zone ; magnetic contacts for doors and windows: zone 2; daytime area volumetric detectors (kitchen, studio): zone 3; sleeping area volumetric detector (bedrooms, hallways, service bathroom); zone 4; Arrangement of the components and wiring layout Study Bedroom Kitchen SYMBOL LEgEND Activator Hallway Bathroom C Burglar-alarm central unit Living room Second bathroom Children bedroom Balcony Contact interface IR sensor Magnetic contact Indoor siren Outdoor siren Burglar alarm MY HOME 93
23 General rules for installation Example: apartment burglar-alarm system The power supply unit can be installed in the area of the electric distribution board. The central u-itnit must be installed in a protected area, that can be reached easily by the user. In order to facilitate arming of the system, an auxiliary transponder arming device should also be included. If installation of the arming device on the outside of the property is not possible or desired, the activation of the volumetric sensor of the living room should be delayed. On the other hand, if the arming device is installed outside, zone will be activated without delay. The system will be completed by the installation of an indoor siren in the hallway area, so that the intruder will be confused by the high noise, and disturbed, and will be unable to hear the police force approaching. An outdoor siren with optic diffuser shall also be installed outside on the balcony, for easy identification from the outside, of the system in alarm state. When positioning the volumetric sensors, it will be necessary to check the coverage area and comply with the recommendations of the following pages. Using the system diagram, ensure that 24 hour autonomy is guaranteed with only one outdoor siren. During the installation of the system, the job of the installer can be made easier by filling a system card, including all the configuration information in one document, as well as consumptions and positioning of the devices. The card will also be useful after installation should, for example the system need extending. Detailed information on the compiling and use of the system card can be found in the system manuals. List of Items required Description ITEM Consumption QuantitY Central unit with dialling device ma Transponder activator L ma 2 Transponder Power supply E46ADCN Jointed pass. IR detector L ma 7 Contact interface ma 2 Outdoor siren 4072L Indoor siren ma Outdoor siren storage battery 3505/2 Indoor siren storage battery 3505/6 Anti-tamper device L Magnetic contact * 8 Configurators 350K * item to be selected based on the doors and windows characteristics 94 MY HOME Burglar alarm
24 installation of modular devices IN FLUSH MOUNTED BOXES the wire burglar-alarm system is compatible with systems made using the axolute, livinglight and MÀtix series and therefore uses the same boxes, supporting frames and cover plates When using standard flush mounted boxes (depth 52 mm) embedded in the mortar level with the plaster/tile, or in any case where the maximum depth from the bottom of the box to the finished wall is less than 60 mm, cut the tamper rod () at the first reference notch, insert it in the appropriate housing, rotate it 90 and then remove it completely E - 504E - 506L 52 mm < 60 mm IMPIANT O ON OF F 90 2 However, if the maximum depth from the bottom of the box to the finished wall plane is 60 mm, insert the appropriate rod protection device (tamper) in its housing (), rotate it 90, and remove it completely E - 504E - 506L mm IMPIANT O ON OF F if the flush mounted box is different from the Bticino standard (box with reduced depth, less than 52 mm), proceed as follows: completely remove the tamper rod < 52 mm < 52 mm Place the tip to the bottom of the box without pushing too hard and cut the rod level with the box insert the rod () protection device (tamper) in the appropriate housing, rotate 90, and remove completely IMPIANT O fix the devices to the flush mounted boxes Warning: the use of the tamper rod for the protection of FLuSH MOuNTED BOXES devices with BTicino supports is a necessary requirement to assure level 2 protection in accordance with CEI 79-2 standard. For the selection of the flush mounted boxes see the general Installation Catalogue. Check that there is no damage at the bottom of the box in the tamper rod working area. Take the necessary measures to solve any problems. ON OF F 90 2 IN WALL MOUNTED BOXES this series of boxes already has a supporting frame for the devices and the livinglight boxes have white cover plate When installing modular devices inside wall mounted boxes or corner boxes proceed as follows: remove the cap (A) from the bottom of the devices by rotating it 90 ; Do not fit the clear protection cover (B) fit the devices inside the wall mounted (or corner) boxes in this case, the anti-tamper protection (C) is already on the box Pay attention to ensure that the tamper rod of the box fits perfectly in the preset hole at the back of the device Warning: BTicino wall mounted boxes are suitable for installation of devices with level performance. For level 2 performance (CEI 79-2 standard) use the box 502PA for angle installation. C 2 A 3 90 B Burglar alarm MY HOME 95
25 General rules for installation Modular power supplies All the power supplies are sold with Tamper device against the opening of the switchboard. Depending on the power supply being used, two types of installations are possible Installation of power supply E47ADCN - E47/2 These devices are installed inside the switchboard F5/8A. If required, install the back-up battery(ies) in the appropriate housing of the 7.2 Ah enclosure F5/8B. For batteries of higher capacity check the compatibility with the F5/8B enclosure. When the N.C. contact is also being used for additional tampering protection of the battery, connect the contact on the F5/8B enclosure to a tamper line of the system. Warning: for batteries of sizes not compatible with F5/8B enclosures use the required DIN switchboard in the general BTicino catalogue. In order to assure level 2 performance in accordance with CEI 79-2 standard, it will be necessary to use wall mounted switchboards with opening and tear protection. If the power supply is installed in switchboards without door, ensure that it is not subjected to water sprays. Installation of power supply E46ADCN These devices are installed inside standard flush mounted or wall mounted switchboards. Warning: In order to assure level 2 performance in accordance with CEI 79-2 standard, it will be necessary to use flush mounted switchboards with opening protection, or wall mounted switchboards with opening and tear protection. If the power supply is installed in switchboards without door, ensure that it is not subjected to water sprays. Ensure that the vents are not obstructed. A two-pole thermal magnetic circuit breaker with contact separation of at least 3 mm must be used, positioned near the power supply. The function of the circuit breaker is to disconnect and protect the power supply. NOTE: For more information and for the wiring requirements refer to the instructions supplied with the power supplies. Battery N.C. contact 96 MY HOME Burglar alarm
26 Central unit with display WALL MOUNTED INSTALLATION after fixing the base and performing all connections, install the central unit ensuring that the cables are arranged in a way that they will not be damaged NOTE Before installing the burglar-alarm central unit ensure that the sliding switch on the back is in the ON position. OF F ON BUS WARNINGS FOR ALL CENTRAL UNITS Warning: both in wall mounted installation and in MultiBOx switchboards, in order to ensure compliance with level 2 of CEi 79-2 standard, it will be necessary to use the 3484 tamper for the protection of the GSM antenna, as explained in the installation manual of the central unit Wall mounted installation of 3485 or 3485B central units. This same method is also used for the installation of the 3486 central unit. impianto on off 2 PROTECTION OF PSTN CENTRAL UNITS FROM LIGHTNING it is good practice to protect the system from lightning by using surge protective devices, SPD, belonging to class ii for the protection of burglar-alarm central units 3485 and 3486 from surges from the telephone line, the use of the Plt device is recommended, connecting the corresponding earth clamp to the "earth" reference of the SPD limiter installed in the apartment switchboard for further details refer to the instructions supplied with the central units or the relevant technical SHEEtS 2 Installation of the 3486 central unit inside a MuLTIBOX switchboard. NOTE: the central units are supplied with the tamper line clamps (-/T) circuited for the use of the local tamper T (wall mounted installation with metal base). This is compulsory to ensure that the central unit complies with level 2 of CEI 79-2 standards in terms of possible tampering (tear protection). For installations inside MuLTIBOX boxes ensure the connection of a NC circuit breaker to the -/T clamps for the tamper function. For further information see the central unit installation manual. impianto on off Local tamper T Tamper line (see note) Burglar alarm MY HOME 97
27 General rules for installation IR detectors ADJUSTABLE IR DETECTOR HC/HS/L/N/NT46 In addition to the indications shown for the installation of modular devices, also take into account that before installing the swivel IR sensor the adjustment fixing screw () at the back of the detector must be loosened in order to allow the detector to turn. Note: the screw will be tightened after the System test and protected zone check, thus setting the central unit in maintenance mode. radio ir detector 3440 Two installation modes are possible: Wall mounted installation Angle installation Before permanently securing the object ensure that the radio communication with the HC/HD/HS/L/N/ NT468 receiver is working correctly. IR MINI DETECTOR N4640 AND N4640B The base of the detector has a particular shape that enables wall mounted installation in 4 different modes: Wall mounted installation Angle installation Front angle installation Tilted angular installation Wall mounted installation Wall mounted installation molla tamper Angle installation Angle installation MOD 98 MY HOME Burglar alarm Note: for other installation modes see the instruction leaflet.
28 Various sensors LAYOUT FOR MAGNETIC CONTACTS During the installation of the magnetic contacts, if a specific underground conduit is not being installed, ensure appropriate surface trunking up to the jambs of doors and windows. The wires of the contacts will then have to be run to the point on the door or window, where the sensor is being installed. The contact wires have a reduced section, which will not cause any problems when refitting the jambs. FLOODING DETECTOR HA/ HB/L/469 Fix the device to the wall using double sided adhesive tape or screws and plugs. After completing the configuration fit the key covers using the spacers supplied. Note: If the sensor cable needs shortening, cut the excess off and connect to the probe terminals. DETECTOR FOR SHUTTERS Place the rope contact preferably in the middle of the rolling shutter box and then fasten it. Then fasten the end of the rope to the rolling shutter with a screw. The rope can be extended up to 3.4 m. NOTE: The rope must be set between the window and the rolling shutter. Check condition of rope and its sliding movement periodically. In order to prevent the rope from rubbing against a sharp part of the rolling shutter, you can glue a square (not supplied) using double-sided adhesive tape. Magnetic contacts Key-cover L/N/NT499 Led Test Reset Burglar alarm MY HOME 99
29 General rules for installation Various sensors piezoelectric windowbreaking detector 356/3444 The detector must be applied to the glazed part to be protected using the special double-sided adhesive tape (supplied). The glazed part must be between.5 and 6 mm thick; the diagonal length must not exceed 3 m (Fig. ). RADIO MAGNETIC CONTACT 3442 The device must be installed inside the house, on doors and windows, including sliding ones, and similar openings, as shown in the figure; the magnetic contact must be fixed in place using the appropriate position adjustment spacers, in order to activate the alarm as soon as the movable part of the door or window starts to move away. Reference tab 2 25 mm min. 25 mm min. MAX 3 m Thickness from.5 to 6 mm 4 3 Note: Clean and dry glasses before applying the detector. Press hard to ensure optimum adhesion. Note: To ensure correct positioning align the reference notches of the magnetic contact of the transmitter 200 MY HOME Burglar alarm
30 IR BARRIERS /50 358/ the two columns must be installed one in front of the other (fig ) in the same direction (both terminal boards placed at the top side or bottom side) (fig 2); the height must be as close as possible to the ground or to the lower part of the window (fig 3), with no fixed or removable obstructions that may interfere with the rays (fig 4) so that the receivers are not directly exposed to sunrays (fig 5) and are not exposed to the rays of other transmitted, either directly or by reflection Each column consists of: aluminium section bar top terminal (base + cover + screw) Bottom terminal (base + cover + screw) 4 screws + 4 screw anchors for wall mounted installation follow the instructions on the instructions leaflet, taking into account the following requirements: the cable can be inserted from the bottom (inside the wall), or from the outside (exposed) in this case open (break) the cable passage hole at the base of the unit the terminal strips can be temporarily removed to help cable connection for the electric connection, refer to the Connection diagrams section WARNINg: Do not use a shielded cable when connecting the barriers to the contact interface. fig. fig. 2 fig. 3 fig. 4 fig. 5 RX Note: for further information see the instruction leaflet supplied with the barriers Burglar alarm MY HOME 20
31 General rules for installation Outdoor siren. Remove the two screws () and take off the external cover (2) Insert the screw plastic plugs into the holes and partly tighten the top screws () and the tamper screw (2). 7. Put the battery () or 2V-2Ah battery - into the special housing without connecting the Faston terminals. Connect the electronic card as shown in the instruction leaflet supplied with the siren Remove the four screws () and pull out the internal protection cover (2) Adjust the tamper screw by using the notch () on the drilling template, as shown in the picture. Warning: If the installation or the adjustment of the tamper screw is carried out incorrectly, the system will not work. 3. By using the drilling template (), position the hole (2) near the wireoutlet pipe and scribe the 5 holes. NOTE: use a Ø 6 mm bit for drilling the holes. TEMPLATE 2 6. Attach the siren to the two top screws (). Tighten the two bottom screws (2). Tighten the four screws completely MY HOME Burglar alarm
32 CONFIGURATION General concepts Configuring the devices of the burglar-alarm system means assigning them their respective addresses and operating modes The address allows you to solely identify each device within the system; conversely, the operating modes are the specific functions performed by each device (central unit, detectors, sirens, etc.). In addition to the typical functions of any burglar-alarm system, such as the tripping delay of a detector or the management of a balanced contact line, it is possible through the configuration of the operating mode to enable the devices in order to perform special functions such as the management of technical alarms (gas leaks, floods, etc.) or alarm signalling by means of auxiliary channels. The address of the device is determined by assigning a value to the positions: Z to specify the number of the assigned zone (compulsory) of the device, if this belongs to the group of detectors. If the device belongs to the group of connectors, this position must not be configured; N to specify the progressive number (compulsory) of the device within the above-mentioned zone. CONNECTION / REMOVAL OF CONFIGURATORS Before configuring the devices remove the clear protection cover (). To facilitate connection or removal of the configurators use the appropriate tool (2). 2 ZONE 0 Activator device ZONE 9 Auxiliary devices Z = 0 N = Z = 0 N = P N = AUX = - MOD = - N = 9 AUX = - MOD = - Central unit 9 max 9 max BUS CLEAR OK ZONE 8 ZONE... ZONE Sensors Z = N = Z = N = 9 9 max 72 devices max. Burglar alarm MY HOME 203
33 Z N AUX Configuration General concepts Z N AUX Example of IR detector configuration. First sensor belonging to zone 2, with pulse count function enabled. Configurator position Z N AUX Z 2 No. MOD AUX Z N MOD AUX Example of contact interface configuration. Fourth sensor of zone 3, with balanced protection of the contact line. Configurator position Z 3 N 4 MOD VALUE none 2 VALUE N.C. N.C. AUXILIARY CHANNELS In addition to the typical functions, the devices of the My Home Burglaralarm system can also perform a range of functions independent from the status of the burglar-alarm system itself (armed or disarmed). This is possible thanks to a particular communication channel of the burglar-alarm and automation bus, called auxiliary channel, used by some devices (such as the auxiliary channel interface or the radio receiver) for the transmission of information such as health emergency, robbery emergency etc. In order to better clarify this concept, the burglar-alarm system may be compared to a 3 lane road, with the first one used for the transit of police cars (information connected to intrusions or burglary), while the second is for service cars (information connected with the operation of the system), and the third lane is for emergency services (information connected with auxiliary alarms or events). Auxiliary devices are capable of handling the sets of information from the three lanes and act accordingly, based on their configuration. If the there is any information connected to intrusion events, the devices activate local signallings (sirens), or remote signallings (telephone dialling devices); if on the other hand the information relates to technical alarms, based on the set operating parameters, the devices activate to generate alarm or prealarm signals, or to reinstate safety within the controlled environment. Some typical examples are the application for the automatic shutting off of the gas piping following the detection of natural gas leaks, described in this guide, and the operation of the burglar-alarm central unit in ADEMCO protocol mode (forwarding of telephone calls to vigilance bodies following a burglar-alarm or a technical alarm event). In this case, when configuring the 3486 central unit, the use of the auxiliary channel with the type of technical alarm that generates the call is already set, as shown in the following table. Tamper line Balance resistance 0 KΩ 5 % /4 W TYPE OF TECHNICAL ALARM COMBINED AUXILIARY CHANNEL T - C - C2 AR T.F482 Gas leak Freezer 2 Flooding 3 T C2 C Anti-panico 4 General technical alarms Fire 8 Remote assistance MY HOME Burglar alarm
34 Configuration example the following drawing shows the example of the configuration of the burglar-alarm system of the apartment described in the section "GEnEral rules for installation" the configuration of the devices depending on the area to be protected is the following: Zone living room: protected by a magnetic contact with interface configured with Z= and n=2 on the entrance door and a volumetric detector configured with Z= and n=; Zone 2 house perimeter: protected by magnetic contacts on the french windows and the windows, connected to three interfaces configured with Z=2 and n= - 3; Zone 3 Kitchen and studio: protected by volumetric detectors configured with Z=3 and n=, and Z=3 and n=2; Balcony Zone 4 bedrooms, hallway, bathroom: protected by volumetric detectors configured with Z=4 and n= 4 Devices such as the indoor siren, the transponder connector, and the separator, are only configured in the n socket corresponding to the number of the device within the system Siren 4072L Bedroom BuS Contact interface Z=2 N=2 Transponder activator N=2 L4607 IR sensor Z=4 N=2 L46 Second bathroom Z=2 N=3 F482 Children's Z=4 N= L46 IR sensor Z=4 N=3 Z=4 N=4 bedroom F482 IR sensor L46 IR sensor L46 Hallway Kitchen Z=3 N=2 N= Indoor siren Bathroom IR sensor L T - C - C2 AR T.F482 Z=2 N= Study IR sensor Z=3 N= L46 IR sensor Z= N= L46 Living room Transponder activator T - C - C2 AR T.F482 N= 02 L4607 Z= N=2 35 T C2 C T C2 C F482 Contact interface F482 Contact interface Burglar alarm MY HOME 205
35 COnfiGuratiOn use of the Youproject program for the configuration of the system the configuration of the system can be performed using the appropriate design program called Youproject, conceived to automatically perform all the specific and predictable functions inside the home automation system (placement of devices, dimensional and electrical calculation, allocation of addresses, configuration of tables ) the software produces a paper report with technical information for the installation of the system, which also includes the configuration, and the list of the necessary materials Youproject program screen with the data of the system to be configured Report generated by the program with the configuration and the list of devices 206 MY HOME Burglar alarm
36 technical alarms: shop burglar-alarm if there is a robbery, the assistant can press a hidden pushbutton which activates the burglar-alarm central unit telephone communicator which sends a request for assistance to the My Home Portal this will warn the owner or people indicated by him, by BURGLAR ALARM means of: one or more telephone calls one or more sms (using the MY HOME portal) one or more (using the MY HOME portal) TV/SAT the activation does not generate IPTVa local sound alarm, so that the robber can be surprised, as he does not know that the call has been made Suspend the call by means of the remote control on the burglar-alarm central unit BuS diffusione sonora antifurto termoregolazione videocitofonia controllo lan controllo carichi energia luci tvcc www irriga TV/SAT OUT SCS/SCS interface IPTV Burglar-alarm central unit Technical alarm interface ART.F422 OK CLEAR N.C. pushbutton Telephone line termoregolazione videocitofonia controllo lan controllo carichi energia luci tvcc www irrigazione To any other systems CONNECTIONS AND CONFIGURATIONS technical alarm interface 348 NOTE*: the auxiliary channel number 7 must also be entered at TV/SAT the programming stage, on the burglar-alarm IPTV central unit, for coupling with the signalling message of the telephone communicator. BURGLAR ALARM BuS diffusione sonora antifurto termoregolazione videocitofonia controllo lan controllo carichi energia luci tvcc www irrig 7 st AuX device No. of auxiliary channel * Anti-burglary mode N.C. pushbutton Burglar alarm MY HOME 207
37 COnfiGuratiOn technical alarms: anti-panic alarm if the owner hears strange noises in the home, he presses a special pushbutton to activate all the Burglar-alarm system sirens (only with the system armed, otherwise only the indoor siren activates) to confuse any intruder with the intense sound BURGLAR ALARM the burglar-alarm central unit telephone communicator sends a request for assistance to the My Home Portal, which warns the owner or people indicated by him, by means of: one or more telephone calls; one or more sms (using the MY HOME portal); TV/SAT IPTV one or more (using the MY HOME portal) this function can be activated with the burglar-alarm system switched on or off and in any division condition Indoor siren (optional) BuS diffusione sonora antifurto termoregolazione videocitofonia controllo lan controllo carichi energia luci tvcc www irr TV/SAT OUT SCS/SCS interface IPTV Burglar-alarm central unit Technical alarm interface ART.F422 OK CLEAR N.C. pushbutton Telephone line termoregolazione videocitofonia controllo lan controllo carichi energia luci tvcc www irrigazione To any other systems CONNECTIONS AND CONFIGURATIONS technical alarm interface 348 TV/SAT IPTV indoor siren HC/HD/HS/ n/nt4070 BURGLAR ALARM BuS diffusione sonora antifurto termoregolazione videocitofonia controllo lan controllo carichi energia luci tvcc www irri 2 st AuX device no configurator anti-panic mode N MOD Indoor siren no configurator N.C. pushbutton N MOD 208 MY HOME Burglar alarm
38 a water pipe leak, or a tap left open, may cause serious damage if not immediately detected With MY HOME, the signal transmitted by the sensor is received by a radio receiver connected to the burglartechnical alarms: flooding control alarm system, which can activate an actuator that controls a solenoid valve in addition, it will also activate an indoor siren and the telephone communicator of the burglar-alarm unit, which sends the assistance request to the MY HOME portal, which will in turn warn the owner, or any nominated individual, by means of: one or more telephone calls; one or more sms messages; one or more s TV/SAT IPTV Indoor siren Radio receiver BURGLAR ALARM BuS sione sonora antifurto termoregolazione videocitofonia controllo lan controllo carichi energia luci tvcc www irrigazione TV/SAT OUT SCS interface IPTV Burglar-alarm central unit Relay actuator ART.F422 OK CLEAR Telephone line Flooding detector videocitofonia controllo lan controllo carichi energia luci tvcc www irrigazione Solenoid valve To any other systems CONNECTIONS AND CONFIGURATIONS relay actuator 3479 TV/SAT NOTE*: the number 4 of the auxiliary channel is the one shown in the AuX socket of the HC/HS/L/N/NT468 IPTV radio receiver. Configuration for manual reset solenoid valve. When using a different solenoid valve connect configurator no. 3 to the MOD socket (bistable mode). BURGLAR ALARM BuS st AuX device iffusione sonora antifurto termoregolazione videocitofonia controllo lan controllo carichi energia luci tvcc www irrigazio 4 No. of auxiliary channel * 6 monostable contact Transformer Solenoid valve Burglar alarm MY HOME 209
39 COnfiGuratiOn technical alarms: flooding control CONNECTIONS AND CONFIGURATIONS radio receiver HC/HD/HS/l/n/nt468 NOTE*: The number of the auxiliary channel must also be indicated during the programming of the burglar-alarm central unit, for coupling to the signalling message of the telephone communicator, as well as in the configuration of the relay actuator that controls the electrovalve. The coupling between the flood detector and the radio receiver must be completed before installing the detector itself. To save the detection device see the Configuration section. 9 zona 9 Z N AUX TV/SAT 4 IPTV st detector device in zone 9 No. of auxiliary channel * BuS BURGLAR ALARM e diffusione sonora antifurto termoregolazione videocitofonia controllo lan controllo carichi energia luci tvcc www indoor siren HC/HD/HS/4070-n/nt4070 BURGLAR ALARM TV/SAT IPTV in alternative to the radio flood detector, contact interface 3480, together with sensor 3482, can also be used BuS e diffusione sonora antifurto termoregolazione videocitofonia controllo lan controllo carichi energia luci tvcc www N MOD N MOD Tamper line NC Alarm reset 3482 st Indoor siren Z= 9 N= no configurator Z2= 9 Interface address Interface address No configurator N2= MOD= MOD2= 8 4 No configurator NO contact technical alarm No. of auxiliary channel (see note above) 20 MY HOME Burglar alarm
40 technical alarms: gas leak alarm with burglar-alarm system the application shows the use of the methane gas detector combined in the burglar-alarm system by means of an auxiliary channel interface When the detector detects gas, by means of the interface it generates BURGLAR ALARM a technical alarm signal managed by the burglar-alarm system to close the solenoid valve and at the same time, makes a telephone call via the central unit/dialling device to the TV/SAT My Home Portal which warns IPTV the owner or people indicated by him, by means of: One or more telephone calls; One or more sms; One or more BuS diffusione sonora antifurto termoregolazione videocitofonia controllo lan controllo carichi energia luci tvcc www irrig TV/SAT SCS/SCS interface OUT IPTV Burglar-alarm central unit Technical alarm interface Relay actuator ART.F422 OK CLEAR Telephone line videocitofonia controllo lan controllo carichi energia luci tvcc www irrigazione Bticino MET ANO Methane gas detector (*) 2 Vdc Solenoid valve Transformer Note: (*) maximum 3 devices with transformer F9/2E maximum 2 devices with transformer HC/HD/HS/L/N/NT454 CONNECTIONS AND CONFIGURATIONS Gas detector HC/HD/HS/l/n/nt45/2 Note: No configuration technical alarm interface 348 Note*: auxiliary channel number must TV/SAT also be indicated while programming IPTV the burglar-alarm central unit to link it to the telephone communicator signalling message. BURGLAR ALARM BuS To transformer F9/2E A + automazione diffusione sonora antifurto termoregolazione videocitofonia controllo lan controllo carichi 4 st AuX device No. of auxiliary channel * technical alarm energia To the auxiliary channel interface From methane gas detector Burglar alarm MY HOME 2
41 CONFIGURATION Technical alarms: gas leak alarm with burglar-alarm system CONNECTIONS AND CONFIGURATIONS Relay actuator 3479 Note*: the auxiliary channel number is that given in the AUX housing of the technical alarm interface 348. TV/SAT Indoor siren HC/HD/HS/4070-N/NT4070 (optional) Note*: The audible signal of the indoor siren does not activate for technical alarms. This function IPTV is performed by the natural gas detector. BURGLAR ALARM BUS diffusione sonora antifurto termoregolazione videocitofonia controllo lan controllo carichi energia luci tvcc www irr Transformer F9/2E nd AUX device No. of auxiliary channel * monostable contact N MOD o 5 st Indoor siren technical alarm deactivation * Solenoid valve L4525/2NO N MOD 22 MY HOME Burglar alarm
42 technical alarms: telephone signalling of the tripping of the general circuit breaker With home switchboards fitted with a SalVaVita StOP&GO circuit breaker, it is possible to be notified when the main circuit breaker trips, due to lightning, electric disturbance or system fault the main condition for this useful function, is that the SalVaVita StOP&GO device is connected to the burglar-alarm system through an interface, for the detection of the status of the earth leakage circuit breaker as soon as one of the above problems occur, the SalaVaVita StOP&GO device automatically closes the tripped circuit breaker and reinstates power supply in full safety if however the fault remains, due to an insulation defect, or line overload, the burglar-alarm system will send an SMS telephone message or a pre-recorded message, to notify the user of the problem the telephone message can also be forwarded to the MY HOME WEB portal, which will then send an alarm message by SMS and/or this function is only valid with 3485 and 3486 central units fitted with telephone communicator b a b ART.3485 _ T OFF ON STOP&gO BUS Central unit BURGLAR ALARM BuS automazione diffusione sonora antifurto termoregolazione videocitofonia Control interface Technical alarm interface st AuX device 3 No. of auxiliary channel * ART. F80CMD 4 technical alarm with normally closed contact 2 3 A select mode 3 ( fault notification) by operating the selector with a flat head screwdriver. NOTA*: auxiliary channel number 3 must also be indicated in the burglar-alarm central unit programming to link it to the telephone communicator signalling message. Auxiliary channels between and 9 can be selected. Burglar alarm MY HOME 23
43 ART.F422 COnfiGuratiOn advanced applications: switching on the lights because of an alarm an interesting application is the possibility of automatically switching on all the lights, or a group of them, inside the home, for a preset time following an intrusion this adds an element of confusion to the sound signal emitted by the siren and the BURGLAR ALARM risk of immediate identification will induce the thief to leave this function is obtained by connecting the automation device and burglaralarm systems with an interface which allows the burglar-alarm TV/SAT central unit and the automation IPTV device devices to dialogue Obviously the lights can also be switched on and off by means of the local control device in the automation system BuS diffusione sonora antifurto termoregolazione videocitofonia controllo lan controllo carichi energia luci tvcc www irr OUT SCS/SCS interface ON GEN general control of the lights TV/SAT IPTV AUTOMATION OFF BuS automazione diffusione sonora antifurto termoregolazione videocitofonia controllo lan controllo carichi energia luci CONNECTIONS AND CONFIGURATIONS SCS/SCS interface f422 TV/SAT General control of the lights H/l4652/2 IPTV BURGLAR ALARM BuS diffusione sonora antifurto termoregolazione videocitofonia controllo lan controllo carichi energia luci tvcc www irr AUTOMATION OUT ART.F422 SCS/SCS interface 4 I/I2/I3= No Configuration TV/SAT I4= interfacing mode MOD= burglar-alarm A PL M A2 PL2 M2 IPTV GEN O/I general configurator No configuration ON control (upper key) and OFF control (lower key) BuS automazione diffusione sonora antifurto termoregolazione videocitofonia controllo lan controllo carichi energia luci 24 MY HOME Burglar alarm
44 usione sonora ermoregolazione usione sonora Advanced applications: remote assistance request with telephone call Old or disabled people can send sends the assistance request to the MY This function can be activated with an assistance request, using a HOME portal, which will then warn the the burglar-alarm armed or disarmed, portable remote control. The signal owner or any nominated individuals, with any type of division. sent is captured by a radio receiver by means of: connected to the burglar-alarm. The one or more telephone calls; burglar-alarm activates an indoor siren one or more sms; and the telephone communicator of one or more . TV/SAT the burglar-alarm central unit, which Indoor siren (optional) IPTV BURGLAR ALARM BUS antifurto termoregolazione TV/SAT SCS/SCS controllo interface videocitofonia Burglar-alarm central unit lan IPTV controllo carichi energia luci tvcc Radio receiver www irrigazione OUT ART.F422 OK CLEAR 4 7 videocitofonia controllo lan controllo carichi Telephone line energia Radio control for Remote assistance luci tvcc www irrigazione CONNECTIONS AND CONFIGURATIONS Radio receiver HC/HD/HS/L/N/NT468 Indoor siren HC/HD/HS/4070-N/NT4070 (optional) NOTE*: If the configurator is not present, auxiliary channel no. 9 is allocated NOTA*: The audible signalling of the indoor siren does not activate for technical automatically. This auxiliary channel number must be indicated also at the alarms. This function is performed by the natural gas detector. programming stage on the burglar-alarm central unit, for coupling with the signalling message of the telephone communicator. zone st receiver device N MOD Z N AUX Indoor siren technical alarm deactivation * No. of auxiliary channel * TV/SAT IPTV N MOD BURGLAR ALARM antifurto termoregolazione videocitofonia BUS controllo lan controllo carichi energia luci Burglar alarm tvcc www MY HOME 25 irrigazione
45 Start-up and testing Start-up Note: this operation must be carried out after configuring the system. In order to startup the system, all devices must be connected and installed properly into their supports. CENTRAL UNIT 3486 When the central unit is switched on for the first time, the Maintenance menu is shown; the slide switch on the back is in OFF position. To activate the central unit and make it operational proceed as follows: choose the language; use the central unit to start the tutorial; move the slide switch to ON; press CLEAR twice to exit the maintenance menu; select Communication - GSM Management menu and enter the PIN code; go to the main screen by holding down CLEAR, switch off the central unit; disconnect the battery; insert the SIM card; connect the battery again and switch the central unit back on again; wait for the battery to fully charge (icon OFF); make sure there is a line connection; wait about one minute; during this time, the PIN ERROR or icons might be displayed. After one minute, both icons should disappear; if they do not disappear, check the PIN code or check if the SIM card is disabled by inserting it in a mobile phone. go back to the maintenance menu; check the reception level of the GSM signal; program any scenarios as needed; Program an IR remote control, a transponder key, or a Numeric code as shown in the following pages; enter time and date; edit the names of the zones and devices and the division scenarios. WARNING: If the central unit battery is exhausted, the GSM module does not operate. Central UNIT l/n/nt4600/4 Remove the support from the box (if already installed) and move the changeover switch () at the back of the device to the OFF position (maintenance). Power the system and check that the central unit is in maintenance mode. This is confirmed by the AUX (2) and 24h (3) red LEDs flashing in succession zone central unit IMPIANTO 24h TEST ALLARME ZONA PROG S ON OFF AUXON IMPIANTO OFF P ALLARME ZONA CENTRAL UNIT 3485/B AND HC/ HD/HS/L/N/NT460 When the central unit is switched on for the first time, the Maintenance menu is shown; the slide switch on the back is in OFF position. To activate the central unit and make it operational: choose the language; use the central unit to start the system tutorial; move the slide switch to ON; press twice to exit the maintenance menu () return to the maintenance menu; program a transponder key or a numeric code; enter time and date; customize zone, device and division scenario names. Central unit 3485 / 3485B Warning: with the system in Maintenance mode, the batteries of the system are not charged. If the system remains in this mode for an extended amount of time, the batteries may be damaged. 26 MY HOME Burglar alarm
46 Common operations for all central units Check if the red LED is on the siren control card. If it is lit, reverse the connection of the Bus pair. Warning: Furthermore, make sure the yellow LED is off; when it is lit, it indicates the alarm condition, hence an abnormal condition in the system. in this case, eliminate the anomaly. Now connect the two faston terminals () to the battery paying attention to the polarity (red +, black -). Warning: when there is a connection with an inversion of polarity, the card will be protected with 4A fuses placed inside the cable (2). Install the two siren protection covers. NOTE: in case a second siren is installed, make sure to repeat the LED check after its installation. The J jumper of the second siren must be cut (see the siren technical sheet). If central unit L/N/NT4600/4 is installed, move the changeover switch (3) at the back of the unit to the ON position (active). Fit the central unit inside the box correctly. Indoor siren card A J 2 B C Yellow LED Red LED 3 A = BUS B = BATTERY (RED+, BLACK -) C = SOUND SIGNALLER Burglar-alarm central unit L/N/NT 4600/4 Burglar alarm MY HOME 27
47 Start-up and testing Programming of 4050 infrared remote controls Central UNIT 3486, 3485/B HC/HD/HS/L/N/NT460 Programming remote controls is facilitated by the information given by the display (see the installation manual of the central unit supplied with the device). Flush mounted central units L/N/NT4600/4 After putting the batteries into the remote controls, with the central unit in maintenance mode (switch on the back in OFF position), press the P pushbutton () using a pencil or similar object. Make sure that the yellow LED PROG (2) is lit and that a short tone is emitted. Place the remote control transmission lens (3) against the central unit receiving lens (4) in order to keep it perfectly aligned (cover the lens in case of interferences with the infrared, e.g. due to the direct light of lamps or spotlights). Press the transmission pushbutton (5) and hold it down until the tone is emitted. A tone lasting about half a second means that the programming process has been executed correctly. NOTE: A tone lasting about 4 seconds means that the programming process has not been executed correctly. hence it will be necessary to repeat the operation. When the remote control programming has been completed, repeat the operation for all supplied remote controls (maximum 30). NOTE: in this stage, it is possible to program remote controls for other systems. After programming the last remote control, press the S pushbutton (6). Make sure the yellow LED PROG (7) is off. Pairing of RADIO remote controls Switch the system to maintenance mode. 2. Press the Radio receiver HC/HD/ HS/L/N/NT468 programming pushbutton for five seconds, until the red LED comes on. 3. Press the connection pushbutton for 5 seconds. 4. If the pairing of the device has been performed correctly, the red LED of the radio receiver will go off.if this does not happen, repeat the procedure from step 3. If the LED flashes, it means that the device memory is full. 5. To save other devices in the radio receiver repeat step Perform self learning of the system from the central unit. 7. Program the remote controls on the central unit, if this is of a type "with display. 8. Exit maintenance mode. 2 4-zone central unit 24h TEST 2 S AUX PROG P Arming Disarming 24h 7 4-zone central unit TEST S AUX PROG P ~ h TEST 2 S AUX PROG P 3 4 Key-ring 6 28 MY HOME Burglar alarm
48 cod3530 R Programming of 3530S and 3540 transponders CENTRAL UNIT 3486, 3485/B HC/HD/HS/L/N/NT460 programming transponders is facilitated by the information given by the display (see Central unit installer manual) FLUSH MOUNTED CENTRAL UNITS L/N/NT4600/4 the transponder (badge) programming operation is necessary in order for it to work as a normal infrared remote control 4050 Please keep in mind that when the transponder-reader is used as a activator, it will almost always be installed in places different from the one in which the central unit is located therefore, it is recommended to temporarily connect it near the central unit the initial programming - which is carried out when installing the transponder reader shall be carried out with the central unit in MaintEnanCE mode (selector switch located on the back in Off position) Procedure:. With central unit in maintenance mode, press the P key and check if the yellow led PrOG lights up 2. re-program the ir remote controls first (see chapter remote COntrOl PrOGraMMinG) 3. now, move the badges towards the transponder reader (figure at bottom left) 4. Make sure that two short tones are emitted: the first is emitted from the transponder reader, the second is emitted from the central unit 5. repeat points 3 and 4 for all available badges 6. When you have finished programming the last badge, press the S pushbutton on the central unit (the yellow PrOG led turns off) and move the back selector switch to On - dwg a DELETING OR ADDING A TRANSPONDER When using central units 3486, 3485/B and HC/HD/HS/l/n/nt460 the deletion of transponders is facilitated by the information given by the display (see Central unit installer manual) in systems with flush mounted central units l/n/nt4600/4, a new programming process is required to delete previously stored transponders or to add new ones follow the procedure described in section remote COntrOl PrOGraMMinG (of course, during this procedure, the badge will have to be moved near the transponder reader instead of the central unit) this procedure will delete all stored transponders (partial deletion is not possible) 4-zone central unit 24h TEST S AUX PROG P IMPIANTO ON OFF LUMINOUS AND AUDIbLE INDICATORS buzzer LED SYSTEM ENABLED 0.5 sec OFF SYSTEM DISABLED 0.5 sec Fixed green INCORRECT ACTIVATION 4 sec Flashing green ALARM OCCURRED - Fixed red DEACTIVATION AFTER ALARM OCCURRED (allows you to check the zone in which the alarm occurred) 0.5 sec Fixed orange bip IMPORTANT: the central unit can save up to 30 system arming/disarming devices. If a transponder is used as a remote control, only 29 devices can be saved. This is because an IR remote control (4050) must always be present. transponder HIGH SECURITY Burglar alarm MY HOME 29
49 TEST Start-uP and testing Programming a remote control or a transponder for several systems CENTRAL UNIT 3486, 3485/B AND HC/HD/HS/L/N/NT460 Programming is facilitated by the information given by the display (see Central unit installer manual) FLUSH MOUNTED CENTRAL UNITS L/N/NT4600/4 if you have two or more burglar-alarm systems with a flush mounted central unit (for example, home and office), it will be possible to program one or more remote controls able to interact with all systems Remote control (transponder) common to the two system ST SYSTEM (OFFICE) 2 ND SYSTEM (HOME) 24h 2 24h TEST 2 S PROG 3 4 S PROG 3 4 AUX P AUX P Office remote control (transponder) Home remote control (transponder) Note: carry out these operations with the two systems already activated: both central units with rear selector switch in ON position. Press the S pushbutton on the central unit of the second system (2) and hold it down Send an impulse using a previously-enabled remote control (keep it at a maximum distance of 50 cm from the central unit) Make sure the yellow led test (3) is on Send a second impulse Make sure the yellow led PrOG (4) is on release the S pushbutton (2) Press the P pushbutton (5) by using a pencil or a similar object Make sure a short tone is emitted Warning: When programming a newly-purchased remote control, first of all do the programming described in chapter REMOTE CONTROL PROgRAMMINg (user manual). NOTE: make sure the system is disabled - green LED () on. 4 4-zone central unit 24h TEST S AUX PROG P Note: all previously stored codes of the remote controls are now deleted and can no longer be recognised by the central unit. Hence, it will be necessary to re-program all remote controls and transponders which will need to act on this system by following the descriptions in chapter REMOTE CONTROL PROgRAMMINg (user manual) MY HOME Burglar alarm
50 Direct the remote control previously programmed on the first system towards a to 4 zone divider or connector of the second system Press the remote control pushbutton as if it were a normal enabling process if a transponder is used, move it towards the transponder reader and wait for the beep sound from now on, the remote control code for the first system will also be recognised by the second system When the remote control programming has been completed, repeat the operation for all remote controls requiring this function (30 altogether) after completing the programming operations, press the S pushbutton () and make sure the yellow led PrOG (2) is off Activator Divider zone to 4 max 50 cm max 50 cm zone central unit transponder transponder 24h TEST S PROG cod3530 HIGH SECURITY cod3530 HIGH SECURITY AUX P 2 Burglar alarm MY HOME 22
51 Start-up and testing System activation SYSTEM WITH central UNIT 3486, 3485/B HC/HD/HS/L/N/ NT460 After completing the operation described in the chapter "Putting into operation" of the system, the central unit becomes operational. Perform a system test as described below. Central unit (3486) rear view ON OFF slide switch impianto on off LU T a b a b SYSTEM WITH central UNIT l/n/nt4600/4 First of all, set the central unit to ON. To activate the system, direct the remote control () towards the receiving lens (2) of the central unit at a maximum distance of 50 cm. Activate the remote control by pressing the pushbutton (3) once or twice with a time interval of 5 seconds between the first and the second time, until the green LED (4) lights up. Activate the remote control with the pushbutton (3), thus making sure that the green LED (4) turns off. Activate the remote control again with the pushbutton (3), thus making sure that the green LED (4) turns on. Make sure that the red LEDs AUX (5) and 24h (6) are off. NOTE: if the two LEDs continue to flash, it means that the selector switch at the back of the central unit has not been set to ON. If the 24h LED is steadily on, it means that one of the devices is producing a 24h alarm. Check if the installation has been carried out properly (see problems/causes/solutions table). Make sure the green LED ~ (7) is on. In this condition, the system is activated and disabled h TEST S AUX PROG P ~ Tamper T T2 Now test the system as indicated in the next pages. 222 MY HOME Burglar alarm
52 System test CENTRAL UNIT 3486, 3485/B AND HC/HD/HS/L/N/NT460 access the Maintenance menu and select test, as described in the installer manual supplied with the central unit. When the system is disabled (led on) press S and hold it down 2. Press the pushbutton of one of the enabled remote controls; the TEST led turns on, hence you can now release the S key 3. after carrying out the verifications described in the following paragraphs ( test procedure ), press S to end the test; Make sure the TEST led turns off TEST PROCEDURE. infrared detector check the red led should light up when passing through the area protected by the detector 2. Contact check the red led of the contact interface should light up when opening the windows or entrance door Central units L/N/NT4600/4 24h TEST 2 S PROG 3 4 AUX P 2 24h TEST S AUX PROG P Warning : when testing, the central unit L/N/ NT/4600/4 does not recognize the remote controls When the rolling shutter controlled by the rope sensor is raised or lowered, the red led of the interface comes on after the number of pulses set, and will go off again after 4 seconds Central units L/N/NT4600/4 24h TEST 2 3 S PROG 3 4 AUX P Burglar alarm MY HOME 223
53 Start-up and testing System test: two line contact interfaces check The interfaces 3480 and F482 are equipped with LED indicators for properly start-up the system. During the startup procedure, the central unit must not be powered. If it is, it must be in test mode.. Connect the interface to the SCS bus and the wires of the contacts and tamper to their terminals. 2. Insert the required configurators and close again using the transparent shell (interface 3480). 3. Close all contacts, including the Tamper. 4. Power the item. Procedure for F482 Tamper contact LED indicator activated T T - C - C2 ART.F482 C2 C Line 2 LED indicator activated Line LED indicator activated 4. If the LEDs start flashing, check the configuration and repeat the startup procedure. If the LEDs flash quickly, only 5/6 times before stopping, go on to the following paragraph. 4.2 If the tamper contact LED is now off, go on to paragraph 4.3); if it stays on, make sure that the tamper line is short-circuited and then repeat the procedure from paragraph 4). 4.3 If the line contact / line contact 2 LEDs are now off, go on to paragraph 4.4); if it stays on, make sure that the contacts of the two lines are closed (e.g. windows closed). 4.4 Make sure the LED is on when opening the various contacts: when the contact is closed (e.g. window closed), the LED must be off, when the contact is open (e.g. window open) the LED must be on. Procedure for 3480 Tamper contact, line, line 2 LED indicator activated 4. If the LEDs start flashing, check the configuration and repeat the startup procedure. If the LED flashes quickly, only 5/6 times before stopping, go on to paragraph 4.2). 4.2 If the LED is now off, go on to paragraph 4.3); if it stays on, make sure: that the tamper line is shortcircuited and then repeat the procedure from paragraph 4) the enclosure of the interface is well closed and then repeat the procedure from paragraph 4) after switching the power off. the contacts of the two lines are closed (e.g. windows closed) and then repeat the procedure from paragraph 4.2) 4.3 Make sure the LED is on when opening the various contacts: when the contact is closed (e.g. window closed), the LED must be off, when the contact is open (e.g. window open) the LED must be on. COMPLETION OF THE TEST STAGE 3486, 3485/B and HC/HD/HS/L/N/ NT460 central units Exit the Maintenance" menu following the procedure described in the installation manual supplied with the central unit. L/N/NT4600/4 central units Once the checks have been completed press pushbutton (), check that the TEST LED (2) has gone off and move the ON-OFF selector (3) to the OFF position. Remove the swivel IR detectors from the box and tighten the screw locking the adjustments h TEST S AUX IMPIANTO ON OFF PROG P 2 ALLARME ZONA 4-zone central unit MY HOME Burglar alarm ALLARME ZONA NTO ON
54 Configuration or system modifications - Maintenance If it is necessary to modify the configuration of the system after starting it up, follow the procedure below after disabling the system: Central UNITS 3486, 3485/B AND HC/HD/HS/L/N/NT460 Go to the Maintenance" menu following the procedure described in the installation manual supplied with the central unit; Disconnect the power supply from the system; Replace or add the configurators to the devices; Connect the power supply; Ensure that the central unit performs the system self-learning procedure; Perform the system test. Central UNITS L/N/NT4600/4 after disabling the system, remove the central unit from the box and set the selector () to OFF within 30 seconds, otherwise a 24h alarm signal will be produced, if the tamper rod has been installed; switch off the system; replace or add the configurators to the devices; switch on the system; flip the selector switch () to ON ; install the central unit in the box; activate the system by sending one or two impulses with the remote control. 4-zone central unit IMPIANTO IMPIANTO ON NOTE: for normal operation of the system, please refer to the guidelines specified in the User manual. OFF ALLARME ZONA ORDINARY MAINTENANCE OF THE BURGLAR-ALARM SYSTEM It is recommended that a test is performerd regularly to check that the system i working correctly, that the system back-up batteries are charged, as well as the condition of any radio devices. ON OFF ALLARME ZONA Warning: If you are going to install a device next to the central unit, do not place the tamper rod in the new device as the system would produce a 24h alarm. The anti-tampering protection is guaranteed by the tamper rod installed on the central unit. Burglar alarm MY HOME 225
CONTENTS MY HOME - BURGLAR ALARM
CONTENTS MY HOME Burglar alarm General features...................... 24 General rules for installation.............. 36 Configuration....................... 53 Start-up and testing...................
MY HOME - SAFETY BURGLAR ALARM
MY HOME - SAFETY BURGLAR ALARM THE NEWS Transponder reader Double technology detector Burglar Alarm Control Unit with telephone dialling device 90 SECTION CONTENTS BURGLAR ALARM 92 General features 98
Burglar-alarm TECHNICAL GUIDE 08. La sicurezza da professionisti MH08AF/GB. BTicino SpA Via Messina, 38 20154 Milan - Italy www.bticino.
BTicino SpA Via Messina, 38 2054 Milan - Italy www.bticino.com Burglar-alarm My Home Burglar-Alarm MH08AF/GB La sicurezza da professionisti TECHNICAL GUIDE 08 This booklet deletes and replaces the previous
Integrated solutions for comfort, energy efficiency, safety, video door entry, and control
Integrated solutions for comfort, energy efficiency, safety, video door entry, and control AUTOMATION Thanks to a wide range of s, MyHOME offers simple and efficient solutions to meet the safety, comfort,
CONTENTS. Software and services General features... 472 MY HOME - SOFTWARE AND SERVICES
CONTENTS Software and services General features...................... 472 471 SOFTWARE AND SERVICES - GENERAL FEATURES YouProject preparing estimates and designing MY HOME home automation systems YouProject
CONTENTS. Radio system catalogue. Catalogue MY HOME 527
CONTENTS Radio system catalogue Catalogue MY HOME 527 RADIO SYSTEM CATALOGUE MY HOME RADIO ZigBee AXOLUTE Automation and technical alarms HB4596 HA4599 H4586 HC4578 HA4596 HB4596 HA4597 HB4597 HA4598 HB4598
Wireless Alarm system s manual
MOUNTVIEW TECH AUSTRALIA PTY LTD Wireless Alarm system s manual ADS A180 Series ADS Security 1/11/2011 1. Before You Begin For your safety and the safety of others, and to ensure that you get the most
SECTION 13850 DETECTION AND ALARM
SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring
ALARM SYSTEM INSTALLATION GUIDE
ALARM SYSTEM INSTALLATION GUIDE Congratulations on the purchase of your Egardia alarm system. Egardia's website www.egardia.com Customer services Please visit www.egardia.com if you would like further
ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems
ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems Content Introduction Preventing unauthorized access by perimeter surveillance Monitoring unauthorized access by indoor surveillance
FSLIMRF05-10 - 15-20 - 25
1. INTRODUCTION FSLIMRF is a fully wireless, battery-powered infrared beam barrier for the protection of doors and windows with alarm radio transmission. The barrier is made up of two aluminium sections
BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS
BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS BURGLAR ALARM SYSTEM EURO ALARM Six zones with the following connection capabilities: One
video door entry system offer
video door entry system offer CATALOGUE 2013 BTICINO Specialists in Video Door Entry Systems BTicino, introduces a complete range of products and systems capable of meeting all application and building
SFERA. NEw. 2 wire. audio ViDEO PUSHBUTTON PANELS
SFERA NEw 2 wire audio ViDEO PUSHBUTTON PANELS new SFERA TWO personalities FOR ONE SINGLE electronic HEART The QR Code provides direct access to multimedia contents. The service is very easy to use, and
Wireless Home Security System Product Manual (Model #80355)
Wireless Home Security System Product Manual (Model #80355) Installation Instructions During set-up, if no key is pressed for 15 seconds it will come out of the setup mode and you will have to start over.
MOBILE CALL GSM Alarm System User s Manual
MOBILE CALL GSM Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Contents Function Introduction Alarm Host Diagram
Examples of installations
Examples of installations Video door entry, automation and burglar alarm Row house The example shows the integration of the automation and burglar alarm system with the Sound System video door entry system,
LW-2000-3A. Wireless Auto Dial Alarm System. Sentry Plus User Manual By Global Gadgets
LW-2000-3A Wireless Auto Dial Alarm System Sentry Plus User Manual By Global Gadgets Main Features Simple to use keypad for operation and control. The system can store up to 9 telephone numbers: positions
Total Protection Alarm System
www.skylinkhome.com Total Protection Alarm System MODEL: SC-10 101A073-001 AUG, 2005. CUSTOMER SERVICE 17 Sheard Avenue, Brampton, Ontario, Canada L6Y 1J3 Tel : (800) 304-1187 Fax : (800) 286-1320 Email
the new wireless home alarm system
the new wireless home alarm system ANDROMEDA s wireless solution offers maximum installation flexibility even where wiring cannot be handled The advantages of Andromeda s wireless system: installation
Security. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000
Security Alarm Central Unit 3 4 Technical KNX Alarm central unit EAM 4000 ETS-product family: Alarm system Product type: Alarm central unit The alarm central unit is a modern alarm system using the KNX
Wireless Alarm System. Panic Button. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location
Wireless Alarm System Panic Button User s Manual Choice ALERT Control all sensors, accessories and remote transmitters from one location Table of Contents Important Safeguards 4 Introduction 5 Activating
WIRELESS HOME ALARM SYSTEM (WHA1)
WIRELESS HOME ALARM SYSTEM (WHA1) IMPORTANT : PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING TO INSTALL AND OPERATE THIS ALARM SYSTEM. SAFETY Please note: Before you start to install this alarm, we
How To Build A Home Automation System On A Tv Remote Control
TECHNICAL GUIDE 2011 MY HOME Design and installation guide CONTENTS MY HOME INTRODUCTION General features........................2 1MY HOME -INTRODUCTION INTRODUCTION - GENERAL FEATURES MY HOME - Build
Intruder Alarm System
Intruder Alarm System GSM & PSTN Wireless and Wired Touch Model 2013-01 V1.0.0 Statment This equipment must be installed and used in strict accordance with the instructions given in this user documentation.
Home Security Alarm System
Home Security Alarm System User Manual (ALM-S02) Read manual carefully before use. PiSector Inc., USA www.pisector.com Thank you for purchasing this home security alarm system. For your safety and better
TS93 EMR T/PT/TDE. Surface applied door closer
TS EMR T/PT/TDE Surface applied door closer Installation instructions: Pull side track mount door closer with smoke detector (EMR T) Push side track mount door closer with smoke detector (EMR PT) Double
WIRELESS ALARM KIT INSTRUCTION MANUAL COMPLETE ALARM SYSTEM FOR HOME OR BUSINESS. Model Number: IT214054
WIRELESS ALARM KIT COMPLETE ALARM SYSTEM FOR HOME OR BUSINESS Model Number: IT214054 INSTRUCTION MANUAL Warranty Details/Support This product is warranted against defects for a period of One year if the
Business/ Home GSM Alarm System
Business/ Home GSM Alarm System BUSINESS/HOME GSM ALARM SYSTEM POWER STATUS RECORD SIGNAL User Manual Profile For a better understanding of this product, please read this user manual thoroughly before
MODELS 7007 Gorilla Cycle Alarm 7017 Gorilla Cycle Alarm with 2-way pager system 1017 2-way pager system
MODELS 7007 Gorilla Cycle Alarm 7017 Gorilla Cycle Alarm with 2-way pager system 1017 2-way pager system Remote Control Motorcycle Alarm System Installation & Operation Instructions Sistema de Alarma de
F454. Web Server. User Manual 05/12-01 PC
F454 Web Server User Manual 05/2-0 PC 2 Web Server Contents Introduction and basic functions 5. Connection modes 6.. Connection to the data network 6..2 Remote connection 6.2 Using the Web Server with
AC-115 Compact Networked Single Door Controller. Installation and User Manual
AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.
Two-way communication, keep checking the commnunication between the panel and accessories, make sure the system safer.
Innovative GSM & WIFI dual network operating platform. On WIFI network, the alarm system will work without any fee. If no WIFI, it will work on GSM automatically. With state-of-the-art WIFI network technology,
INTRUSION ALARM SYSTEM
INTRUSION ALARM SYSTEM Case studies reveal most burglars are deterred by the mere presence of an alarm system. Burglars attack unprotected premises considerably more often than ones protected by alarm
GSM ALARM SYSTEM USER MANUAL
GSM ALARM SYSTEM USER MANUAL 1. Instruction The alarm system is based on GSM network. With a GSM SIM card, it can be used wherever you want and no need to connect any wire, which is convenient and easy
GSM Home Alarm System User Manual. http://www.usmartbuy.com
GSM Home Alarm System User Manual http://www.usmartbuy.com 1 1. Factory default Normally, all sensors in the big box have been coded (learnt) to the control host Operation Password: 0000 Long-Distance
LCD -based Intelligent Burglar Alarm System. User Guide. Ver 2.0
LCD -based Intelligent Burglar Alarm System User Guide Ver 2.0 Table of Content 1. Introduction... 2 1.1 General Description... 3 1.2 System Features... 3 2. Anatomy of the LCD-based Intelligence Burglar
Intruder alarm. Pro 21 TM /Solfà TM. Installation and operating instructions N0064EG2/00
Intruder alarm Pro TM /Solfà TM Installation and operating instructions N00EG/00 Contents General presentation..., Presentation of a system with zones..., Product guide... Typical installation Preparation...
HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12)
HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12) UL864 (Commercial Fire) Compliance General Requirements The VISTA-128FBPT/VISTA250FBPT
DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS
Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short
Wireless Home Security Alarm System AM 500
Wireless Home Security Alarm System AM 500 12 MONTH GUARANTEE Installation & Operating Instructions INTRODUCTION The AM500 is a simple self-contained alarm system. It protects the home by sounding a siren
PhoneWatch Smart Security System User Manual - Domonial
PW0002 10/13 Customer Support: 1850 753 753 PhoneWatch Ltd., Unit 3/4, Sandyford Park, Burton Hall Rd, Sandyford Industrial Estate, Dublin 18. Email: [email protected] PhoneWatch Smart Security System
WIRELESS MAGNETIC CONTACT
WIRELESS MAGNETIC CONTACT The magnetic contact wireless MAG HCS is a sensor able to detect opening or closing doors or windows and transmits via radio a alarm signal. It is composed of two distinct elements:
GSM Alarm System User Manual
GSM Alarm System User Manual For a better understanding of this product, please read this user manual thoroughly before using it. Quick Guider After getting this alarm system, you need to do the following
PROFESSIONAL HOME ALARM SYSTEM. Important! Please read these instructions carefully.
WIRELESS AUTODIAL HOME ALARM SYSTEM AM2000 Instructions for use Important! Please read these instructions carefully. IMPORTANT 1 IDENTIFICATION PLEASE CONTACT BEFORE RETURNING THIS PRODUCT TO THE RETAILER
WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER
BAT.LOW AC WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER THE SYSTEM THAT CALLS YOU! Our WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER is designed to allow you to create your own security system.
WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER
BAT.LOW AC WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER THE SYSTEM THAT CALLS YOU! Our WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER is designed to allow you to create your own security system.
Wireless Alarm System. Window/Door Sensor. User s Manual. Choice ALERT. Control all Sensors & accessories from one location
45131 Wireless Alarm System Window/Door Sensor User s Manual Choice ALERT Control all Sensors & accessories from one location Table of Contents Important Safeguards 4 Introduction 5 Installation 6 Assigning
MODELS 8007 Gorilla Cycle Alarm 8017 Gorilla Cycle Alarm with 2-way pager system 1018 2-way pager system
MODELS 8007 Gorilla Cycle Alarm 8017 Gorilla Cycle Alarm with 2-way pager system 1018 2-way pager system Remote Control Motorcycle Alarm System Installation & Operation Instructions Sistema de Alarma de
SECURITY SYSTEM NOTES SPECIAL CODES. Security System Configuration
Installing / Service Company: SECURITY SYSTEM NOTES For Service Call: Master Code SPECIAL CODES Duress Code Security System Configuration Auxiliary Code(s) Quick Arm" Digit: 2 9 3 10 4 11 5 12 6 13 7 14
WIRELESS STATUS MONITOR
INSTALLATION INSTRUCTIONS WIRELESS STATUS MONITOR (WSM or AUWSM) The most current version of this document is available for download at: http://www.ir-swa.com P/N: M053-032-D Schlage 245 W. Roosevelt Road,
How To Use A Power Supply On A Powerline 2.2 (Ai)
KNX/EIB Product documentation Issue: 05.08.2010 629x1220 Push button sensor 3 comfort 1-gang Push button sensor 3 comfort 2-gang (1+1) Push button sensor 3 comfort 3-gang Push button sensor 3 comfort 4-gang
Business/Home GSM Alarm System. Installation and User Manual
Business/Home GSM Alarm System Installation and User Manual Brief Introduction: GSM 900/1800/1900 bands, can be used in most parts of the world Full duplex communication with the host Monitor the scene
S I E R R A PRODUCT INFORMATION GUIDE FOR HOME SECURITY. SIERRA Page 1
S I E R R A PRODUCT INFORMATION GUIDE FOR HOME SECURITY SIERRA Page 1 C O N T E N T S USING YOUR SIERRA SYSTEM: Turning On/Off Home Arming Instant Home Arming Quick Exit Mode Chime Mode SPECIAL FUNCTIONS:
SECURITY SYSTEM NOTES. Security System Configuration
Installing / Service Company: For Service Call: SECURITY SYSTEM NOTES Security System Configuration Master Code: Auxiliary Code(s) 2 3 4 5 6 "Quick Arm" Digit: Exit Delay Time Auxiliary Exit Delay Time
500r+ Installation and User Guide
500r+ Installation and User Guide Compatible Equipment 502rUK-50 Watch/Pendant PA. 509rUK-50 Smoke Detector 515rUK-00 10 metre passive infra red movement detector. 525rUK-00 Remote Set/Unset (Full and
PiSector Home security systems
PiSector Home security systems User Manual (ALM-S02) Read manual fully before use. PiSector Inc., USA, www.pisector.com Thank you for purchase this alarm system, For proper use and your safety, please
SECURITY CAMERA INSTRUCTION MANUAL ENGLISH VERSION 1.0 LBC5451. www.lorextechnology.com
SECURITY CAMERA INSTRUCTION MANUAL ENGLISH VERSION 1.0 LBC5451 www.lorextechnology.com Contents 1x Camera and mounting stand 1x Power adapter 1x Mounting kit 1x Allen key 1x Screw cap 1x 60 ft. (18m)
TYXIA. *2702178_Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF 642-1 channel
Installation and User Guide TYXIA Wireless receiver TYXIA RF 642-1 channel DELTA DORE Bonnemain - 35270 COMBOURG - France E-mail : [email protected] Unit compliant with the requirements of directives:
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
Self-Install Security System Installation and User Guide
Self-Install Security System Installation and User Guide Contents Installation Installation guide 4 Codepad and accessories 6 Step 1 Determine security system location 8 Step 2 Mounting motion sensors
1pcs. 1pcs. 2pcs 1pcs 1pcs 2pcs
Home security alarm system LX-HS06 Instruction Brief introduction LX-HS06 is a set of entirely new English home security alarm system, it uses advanced MCU control and SMD technology. it innovate multiple
User Guide. Model: MAS-WA-SYS
User Guide Model: MAS-WA-SYS CONTENTS Section : Getting started... 4. General system overview. Introduction to the system.3 Items included with the system.4 Introduction to the Wireless Alarm Panel.5 Introduction
INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930
INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................
Wireless Alarm System. Wireless Keypad. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location
Wireless Alarm System Wireless Keypad User s Manual 1 2 3 4 Choice ALERT Control all sensors, accessories and remote transmitters from one location Table of Contents Important Safeguards 4 Introduction
Advanced Fencing and Security Technologies Ltd
G.M. Advanced Fencing and Security Technologies Ltd P.O. Box 2327 Kfar Sava Industrial Area 44425, Israel Tel +972-9-7662965 Fax + 972-9-7662964 E-mail: [email protected] Website: www.gmsecurity.com
Auto Dialer. Manual E-921APQ E-921GPQ
Troubleshooting: Auto dialer will not arm/disarm Auto dialer will not dial out Unit doesn t respond to a call-back Difficulty in activating room monitor by telephone remote control Make sure that you have
D45. SySTEm. ThE high-performance
D45 ThE high-performance SySTEm Security monitoring system with digital BUS technologies High efficiency system and quick installation for both backbone and riserdevicesthankstotheuse of cat.5e UTP cables
Conventional Fire Detection and Extinguishant Control System Specification
Conventional Fire Detection and Extinguishant Control System Specification Page 1 of 9 Scope Furnish a complete 24VDC Conventional, electrically supervised, combined fire detection and extinguishant release
o^c a (fg 1) Telephone Line Socket ( flcg. 2b ) ) fig. 2a ) TeiePhone b ^^I r DC Adaptor
INTRODUCTION Our jnique passive in`raroc ^ys,e^ii conccotrates on the protected area you select. Whenever the unit is set at ARMED, the motion detector will concentrate on the protected area. Once there
PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE
MODEL HAA51 PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE OPERATING MANUAL HAA51 PASSIVE INFRARED INTRUDER DETECTOR INTRODUCTION HAA51 Passive Infrared
Additional Instruction
Additional Instruction Note: a. Please connect the camera with 2.4G WIFI router or Ethernet cable, can t support 5G router. b. For first time wifi connection, please put your mobile close to camera within
NetworX NX-6V2. LED Keypad User Manual
NetworX NX-6V2 LED Keypad User Manual POWER Light is on when AC power is present; flashes to indicate a low battery condition. ARMED Light is on when armed; off when disarmed; flashes to indicate a previous
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10
TECHNICAL SPECIFICATIONS Page 1 of 10 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC conventional, electrically supervised, zone annunciated, fire detection and alarm system as specified
MY HOME - CONTROL 130
130 MY HOME - CONTROL SECTION CONTENTS 132 General features 142 Catalogue My home control 131 MY HOME GUIDE PROJECT AND INSTALLATION MY HOME control The home management and control from distance As well
Wireless AUTODIAL GSM SMS Home Alarm Security System 900/ 1800/ 1900Mhz(CK-GSM-9003)
CN2HK LIMITED Wireless AUTODIAL GSM SMS Home Alarm Security System 900/ 1800/ 1900Mhz(CK-GSM-9003) User Manual Please read this manual before operating this product. After you finish reading this manual,
Overview. Components of an alarm system Technology behind the equipment Communication Platforms Industry Terminology False Alarm Tips DSC products
Basic Security 101 Overview Components of an alarm system Technology behind the equipment Communication Platforms Industry Terminology False Alarm Tips DSC products Components of an Alarm System Main Control
Understanding Alarm Systems
Understanding Alarm Systems A false alarm occurs when an alarm signal designed to elicit an immediate emergency Law Enforcement, Fire, or Medical response is activated, when in fact no emergency exists.
F453. TiF453. User guide 10/11-01 PC
F453 TiF453 User guide 10/11-01 PC 2 TiF453 User guide Contents 1. Hardware and Software requirements 4 2. Installation 4 1.1 Minimum Hardware requirements 4 1.2 Minimum Software requirements 4 3. Fundamental
MOUNTING AND OPERATING INSTRUCTIONS
MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall
Wireless Auto-dial Intruder Alarm System
Wireless Auto-dial Intruder Alarm System User Manual User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Features and Function 1.
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
SPECIAL CODES AUXILIARY CODES SYSTEM NOTES
Installing/Service Company Monitoring Center SPECIAL CODES Master Code Duress Code AUXILIARY CODES "Quick Arm" " Chime" 08 02 09 03 10 04 11 05 12 06 13 07 14 SYSTEM NOTES Exit Delay Time Entry Delay Time
Shunt lock function 3066
Version: January 2004 Contents Alarm System Activation unit Deactivation unit Digital locking cylinder or Smart Relay 1.0 Method of Operation 4 1.1 General 4 1.2 Turning the Alarm System On 4 1.3 Turning
Intelligent GSM Auto-Dial Alarm System
Auto-dial Alarm System Intelligent GSM Auto-Dial Alarm System Profile For a better understanding of this product, please read this user manual thoroughly before using it. 2013.2.V1.0 Auto-dial Alarm System
QFP910. Water detector. Building Technologies. CE1N2732en. Synco living
2 732 Synco living Water detector QFP910 Wireless radio sensor to record water puddles RF communication based on KNX standard (868 MHz unidirectional) Battery operation with standard 1.5 V batteries Use
720r Addendum: Siting the 720r
720r Addendum: Siting the 720r UK 1 Cooper Security Limited 2013 Every effort has been made to ensure that the contents of this leaflet are correct. However, neither the authors nor Cooper Security Limited
Emergency Dialer DIAL-ALERT MODEL: AD-105. www.skylinkhome.com
www.skylinkhome.com Emergency Dialer TM DIAL-ALERT MODEL: AD-105 If you would like to order Skylink s products or have difficulty getting them to work or download information and user manual, please :
Security GSM Alarm System
KONLEN TECHNOLOGY LIMITED Website: www.konlen.com Add:, 3/F, Building5, Kaijieda Industry Zone, Huachang Road, Longhua, Shenzhen China Tel: +86-(0)755-29709632 E-mail: [email protected] [email protected]
868 Mhz. Wirefree DIY. Friendly. Easy Fit Range of Alarms
DIY Friendly Easy Fit Range of Alarms 60% of burglaries attempted on UK homes fitted with burglar alarms are unsuccessful. Introducing the new Easy Fit range of alarms With decades of experience in residential
FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS
FLEET MANAGEMENT & CAR SECURITY SYSTEM FOR PROVIDERS AND CUSTOMERS The Tracker Server Communication Program for data collection The Tracker Client Map Program intended for dispatching desks The GSM/GPRS
User Manual THR840DUK Digital Thermostat
User Manual THR840DUK Digital Thermostat 50051982-001 Rev. A WARNING: This product must be correctly installed and configured to work properly (see pages 12-24). If you are not experienced in wiring electrical
SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE
SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE Cable Processor Module overview WARNING! When tipping the Cable Processor Module back, (after removing the toggle arm pin), use extreme caution not to drop
WITURA CORPORATION SDN BHD
WT 1010SA Stand Alone GSM Alarm System User Manual and Installation Instructions Version: 1.2 Updated: 4 JAN 2012 WITURA CORPORATION SDN BHD Stand Alone GSM Alarm System Instruction Manual 1 Introduction:
428 MY HOME Structured cabling system for the home sector
428 MY HOME Structured cabling system for the home sector CONTENTS MY HOME Structured cabling system for the home sector General features. 384 General rules for installation. 400 Wiring diagrams. 404 Structured
Keys to understanding your alarm system
Keys to understanding your alarm system This section is designed to allow you to familiarize yourself with most of the security system devices that may be installed or proposed to be installed in your