ASCO 920 Product Specifications

Size: px
Start display at page:

Download "ASCO 920 Product Specifications"

Transcription

1 ASCO is the global leader in power switching and controls ASCO 90 Product Specifications Only (Panelboard Mounting),,. Suitable insulation must be behind switch unit.. Suitable for bus bar mounting. Lugs not supplied.. Dimensional data is approximate and subject to change. -/ (0) 8-/ () -/ (89) 0-00 (.) -/ (0) 9-/ () -/ (89) 0- (.) With Sub-Panel (Panelboard Mounting) NEMA Type Enclosure -/ (0) -/(98) -/8 (98) (0) 8-/() -/ () 8(.) -/ (0) -/(8) -/(00) (0) -/ () (.0) (0) (0.) (.0). Enclosure gutter spaces are based on non-looping of cables within the enclosure. Where cables must be looped within the enclosure, oversize cabinets are available at extra cost. Contact ASCO for complete information. Maximum Voltage s at Rated, Open or Enclosed When Connected Pole to Load VAC 0 VAC VAC When Connected Poles to Load on and Poles to Load on 80 VAC 0 VAC 00 VAC A SCO Power Te chnologies 0 Hanover Road F l o r ham Park, NJ 09 USA A SCO w w w. em er so n n et workpower.com / A SCO w w w. ascoapu.co m. For DC service, maximum current rating is amps or switch rating, whichever is less, with maximum voltage rating of volts when connected pole to load and 0 volts when connected poles to load. Current Values and Recommended Control Circuit Size,, Volts, 0 Hz 0 0 Volts, 0 Hz 8 0 Volts, 0 Hz 80 Volts, 0 Hz. Overcurrent protective device ratings for control circuits should be selected and installed in accordance with the NEC.. This table shows the minimum permissible control circuit fuse size, based on the operating coil s momentary inrush current. 8. ASCO furnished control fuses are rated at. Wire Size for Service and Control Connections 9, AL or CU Terminal Lug Wire Range AWG-MCM / Maximum Distance Between Control Station and One ASCO 90 RC with Source Line Voltage at 90% of Normal of Cable per Terminal Lug Connector Control circuit connections are supplied with terminals accommodate a copper wire range of # AWG to #0 AWG. 0. Service connection for switches on sub-panels are furnished with solderless lugs to accommodate copper or aluminum wire, except on 0 Amp size which is provided with / studs. 0- AWG 0 0 Distance in Feet, 0 Volts, 0 Volts, Volts, If the control device does not have adequate current-carrying capacity to control the switch directly, or the control station is to be located a greater distance from the switch than is allowed in the above table, auxiliary control relays for -wire, or -wire control are available. See optional accessories on inside tab.. For 08 volt system, reduce 0 volt values by %.. For volt system, reduce volt values by %. Emerson Network Power. The global leader in enabling Business-Critical ContinuityTM. AC Power Connectivity Embedded Computing Embedded Power Infrastructure Management & Monitoring Outside Plant DC Power Industrial Power Power ing & Controls EmersonNetworkPower.com Precision Cooling Racks & Integrated Cabinets Services Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. 0 Emerson Electric Co. Publication 0 R September, 0 Printed in the U.S.A.

2 Maximum reliability and excellent value ASCO 90 Remote Control (RC) es ASCO 90 Remote Control in Type Enclosure The ASCO 90 is designed as a feeder disconnect switch for load capacities beyond the ASCO 9. ASCO 90 RC switches are available for separate mounting in NEMA type enclosures or direct mounting within lighting panelboards for total or splitbus applications. It is available from 0 through Amperes per pole with or poles and service voltages through 00 volts AC. The ASCO 90 is listed under UL 08 for ballast lighting, tungsten, general use and resistive loads. It also ASCO 90 Ordering Information meets the withstand current requirements of UL for panelboard applications. The ASCO 90 is easy to install and features all position mounting, no derating for high inrush loads and a reliable single-solenoid operator. ASCO 90 RC switches can be used with energy management systems which automatically control lighting and power circuits through control devices such as photoelectric cells, microprocessors, timers and occupancy sensors. Product Code of Poles 90 Continuous Ampere UL listed. CSA Approved Meets UL requirements with short-circuit rating (Withstand Current ) of,000 rms symmetrical at 80 volts for use with molded case circuit breakers; 00,000 rms symmetrical at 00 volts for use with currentlimiting fuses. Interrupts 00% of rated current at 80 volts, 0. to 0. power factor ASCO 90 Optional Auxiliary Control Relays Features Voltage Code AC/DC AC Voltage to 0V 08 to 0V to V 0 to 80V 9 Other Voltages Up to 80 X Sub-Panel Code 0 = No Sub Panel = Sub-Panel Enclosures Options Leave Blank for No Options. X Indicates Options. List Separately. See Below. Leave Blank for Open - Type. C Indicates NEMA Type, or Specify Other Type Required.. For DC service, maximum current rating is or switch rating, whichever is less, with maximum voltage rating of volts when connected pole to load and 0 volts when connected poles to the load.. All at 0 or 0 Hz. For voltages other than those listed, and for DC applications, contact your nearest ASCO source.. Specified only when ASCO 90 is to be mounted within a panelboard. A sub-panel is required when mounting in NEMA type enclosures Example: The catalog number for an ASCO 90, -pole, -amp switch with a control coil voltage of volts, 0 Hz, with an Optional Accessory 8 and a sub-panel, in a NEMA Type enclosure is: 90XC with option 8A(0V) Allows control of RC switches directly from energy management systems. UL recognized for use with ASCO RC switches. Permits low voltage AC or DC normal. Polycarbonate dust cover for protection against industrial environment. Barrier screw type terminals with approved means for solderless connection of conductors. Low VA burden. Auxiliary Control Relays to Operate RC es are useful when: When the controlling device does not have adequate current-carrying capacity to directly control the RC switch. When the control station is to be located at a distance greater than the allowable RC switch line run. When the controlling device is only available as a single pole, single throw contact, necessitating a two-wire control line. Narrow width design. Incorporates ASCO relays. When Form (start-stop) control for an RC switch is required. Two-Wire Control Accessory Catalog A0 Two-wire ASCO relay for two-wire control. ASCO 90 Features Electrical Features The largest service organization of its kind Creative, responsive, customer - focused and competitive. Optional Accessories Can be used with metal halide, mercury vapor, quartz halogen, tungsten and fluorescent lighting. No derating when used on high inrush loads such as cold tungsten lamps. Wide arc gaps and arc splitters to quickly extinguish arcs. Isolated arcing chambers are widely spaced and symmetrically located. Construction Features Long life. Designed for more demanding lighting contactor use. Provides extended life and quieter operation. Suitable for use with energy management systems. Rugged molded base and cover with superior electrical insulation. Control line terminal clamps simplify installation: Insert wire and tighten. Wire range # AWG to #0 AWG. Option Description Auxiliary contacts, one normally open and one normally closed. Supplied as a pair. Rated 0 amps at 80 VAC. Fully-rated neutral plate Auxiliary control relay for -wire control Auxiliary control relay for -wire control Auxiliary control relay for Form control Control line fuse: For grounded control voltage (to 00V) For ungrounded control voltage (to 00V) For ungrounded control voltage (0-00V) Contacts are power-driven in both directions for complete dependability. No extra wires or contacts needed to install signal lamps at control stations. Can be mounted in any Provisions for manual position. operation during inspection and maintenance. Available from stock from 0-. Lightweight for easy installation. Plug-in auxiliary control relays available. ASCO 90 Remote Control with sub-panel See Notes Specify Option A and B,,,,,, 8 9, A B C. A maximum of one pair of optional A and B contacts can be supplied on the above indicated remote es.. The Amperage of the neutral plate will be equal to the Amperage of the specified remote. Lugs capable of accommodating the same cables as a single main pole are provided.. When ordering specify desired control voltage. See next page for control voltages.. Control line fuses can be used to supply power from the remote enclosures to external control stations. Any incoming service or control power should have appropriate overcurrent protection at their source as required by application codes. For a grounded control voltage, one fuse should be ordered; for an ungrounded control voltage, two fuses should be ordered.. Shipped loose for open types. Installed for enclosed types.. U.L. recognized.,0, 08, 0, VAC, 0 or, or 0VDC Accessory Three-Wire Control Accessory 8 Catalog A Three-wire ASCO relay for three-wire control.,0, 08, 0, VAC, 0 or,,,, 8 or 0VDC Accessory 8 Dimensions inches (mm) for ASCO two-wire and three-wire Control Relays -/ (mm) (mm) -/8 8 (mm). Dimensional data is approximate and subject to change. Operating Coil Characteristics Accessory Accessory 8 Nominal AC Pickup Voltage AC Nominal DC Pickup Voltage DC Maximum Voltage.0 VA. Watts 80% of Nominal 0% of Nominal.0 VA. Watts % of Nominal 0% of Nominal

3 ASCO is the global leader in power switching and controls ASCO 90 Product Specifications Only (Panelboard Mounting),,. Suitable insulation must be behind switch unit.. Suitable for bus bar mounting. Lugs not supplied.. Dimensional data is approximate and subject to change. -/ (0) 8-/ () -/ (89) 0-00 (.) -/ (0) 9-/ () -/ (89) 0- (.) With Sub-Panel (Panelboard Mounting) NEMA Type Enclosure -/ (0) -/(98) -/8 (98) (0) 8-/() -/ () 8(.) -/ (0) -/(8) -/(00) (0) -/ () (.0) (0) (0.) (.0). Enclosure gutter spaces are based on non-looping of cables within the enclosure. Where cables must be looped within the enclosure, oversize cabinets are available at extra cost. Contact ASCO for complete information. Maximum Voltage s at Rated, Open or Enclosed When Connected Pole to Load VAC 0 VAC VAC When Connected Poles to Load on and Poles to Load on 80 VAC 0 VAC 00 VAC A SCO Power Te chnologies 0 Hanover Road F l o r ham Park, NJ 09 USA A SCO w w w. em er so n n et workpower.com / A SCO w w w. ascoapu.co m. For DC service, maximum current rating is amps or switch rating, whichever is less, with maximum voltage rating of volts when connected pole to load and 0 volts when connected poles to load. Current Values and Recommended Control Circuit Size,, Volts, 0 Hz 0 0 Volts, 0 Hz 8 0 Volts, 0 Hz 80 Volts, 0 Hz. Overcurrent protective device ratings for control circuits should be selected and installed in accordance with the NEC.. This table shows the minimum permissible control circuit fuse size, based on the operating coil s momentary inrush current. 8. ASCO furnished control fuses are rated at. Wire Size for Service and Control Connections 9, AL or CU Terminal Lug Wire Range AWG-MCM / Maximum Distance Between Control Station and One ASCO 90 RC with Source Line Voltage at 90% of Normal of Cable per Terminal Lug Connector Control circuit connections are supplied with terminals accommodate a copper wire range of # AWG to #0 AWG. 0. Service connection for switches on sub-panels are furnished with solderless lugs to accommodate copper or aluminum wire, except on 0 Amp size which is provided with / studs. 0- AWG 0 0 Distance in Feet, 0 Volts, 0 Volts, Volts, If the control device does not have adequate current-carrying capacity to control the switch directly, or the control station is to be located a greater distance from the switch than is allowed in the above table, auxiliary control relays for -wire, or -wire control are available. See optional accessories on inside tab.. For 08 volt system, reduce 0 volt values by %.. For volt system, reduce volt values by %. Emerson Network Power. The global leader in enabling Business-Critical ContinuityTM. AC Power Connectivity Embedded Computing Embedded Power Infrastructure Management & Monitoring Outside Plant DC Power Industrial Power Power ing & Controls EmersonNetworkPower.com Precision Cooling Racks & Integrated Cabinets Services Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. 0 Emerson Electric Co. Publication 0 R September, 0 Printed in the U.S.A.

4 Maximum reliability and excellent value ASCO 90 Remote Control (RC) es ASCO 90 Remote Control in Type Enclosure The ASCO 90 is designed as a feeder disconnect switch for load capacities beyond the ASCO 9. ASCO 90 RC switches are available for separate mounting in NEMA type enclosures or direct mounting within lighting panelboards for total or splitbus applications. It is available from 0 through Amperes per pole with or poles and service voltages through 00 volts AC. The ASCO 90 is listed under UL 08 for ballast lighting, tungsten, general use and resistive loads. It also ASCO 90 Ordering Information meets the withstand current requirements of UL for panelboard applications. The ASCO 90 is easy to install and features all position mounting, no derating for high inrush loads and a reliable single-solenoid operator. ASCO 90 RC switches can be used with energy management systems which automatically control lighting and power circuits through control devices such as photoelectric cells, microprocessors, timers and occupancy sensors. Product Code of Poles 90 Continuous Ampere UL listed. CSA Approved Meets UL requirements with short-circuit rating (Withstand Current ) of,000 rms symmetrical at 80 volts for use with molded case circuit breakers; 00,000 rms symmetrical at 00 volts for use with currentlimiting fuses. Interrupts 00% of rated current at 80 volts, 0. to 0. power factor ASCO 90 Optional Auxiliary Control Relays Features Voltage Code AC/DC AC Voltage to 0V 08 to 0V to V 0 to 80V 9 Other Voltages Up to 80 X Sub-Panel Code 0 = No Sub Panel = Sub-Panel Enclosures Options Leave Blank for No Options. X Indicates Options. List Separately. See Below. Leave Blank for Open - Type. C Indicates NEMA Type, or Specify Other Type Required.. For DC service, maximum current rating is or switch rating, whichever is less, with maximum voltage rating of volts when connected pole to load and 0 volts when connected poles to the load.. All at 0 or 0 Hz. For voltages other than those listed, and for DC applications, contact your nearest ASCO source.. Specified only when ASCO 90 is to be mounted within a panelboard. A sub-panel is required when mounting in NEMA type enclosures Example: The catalog number for an ASCO 90, -pole, -amp switch with a control coil voltage of volts, 0 Hz, with an Optional Accessory 8 and a sub-panel, in a NEMA Type enclosure is: 90XC with option 8A(0V) Allows control of RC switches directly from energy management systems. UL recognized for use with ASCO RC switches. Permits low voltage AC or DC normal. Polycarbonate dust cover for protection against industrial environment. Barrier screw type terminals with approved means for solderless connection of conductors. Low VA burden. Auxiliary Control Relays to Operate RC es are useful when: When the controlling device does not have adequate current-carrying capacity to directly control the RC switch. When the control station is to be located at a distance greater than the allowable RC switch line run. When the controlling device is only available as a single pole, single throw contact, necessitating a two-wire control line. Narrow width design. Incorporates ASCO relays. When Form (start-stop) control for an RC switch is required. Two-Wire Control Accessory Catalog A0 Two-wire ASCO relay for two-wire control. ASCO 90 Features Electrical Features The largest service organization of its kind Creative, responsive, customer - focused and competitive. Optional Accessories Can be used with metal halide, mercury vapor, quartz halogen, tungsten and fluorescent lighting. No derating when used on high inrush loads such as cold tungsten lamps. Wide arc gaps and arc splitters to quickly extinguish arcs. Isolated arcing chambers are widely spaced and symmetrically located. Construction Features Long life. Designed for more demanding lighting contactor use. Provides extended life and quieter operation. Suitable for use with energy management systems. Rugged molded base and cover with superior electrical insulation. Control line terminal clamps simplify installation: Insert wire and tighten. Wire range # AWG to #0 AWG. Option Description Auxiliary contacts, one normally open and one normally closed. Supplied as a pair. Rated 0 amps at 80 VAC. Fully-rated neutral plate Auxiliary control relay for -wire control Auxiliary control relay for -wire control Auxiliary control relay for Form control Control line fuse: For grounded control voltage (to 00V) For ungrounded control voltage (to 00V) For ungrounded control voltage (0-00V) Contacts are power-driven in both directions for complete dependability. No extra wires or contacts needed to install signal lamps at control stations. Can be mounted in any Provisions for manual position. operation during inspection and maintenance. Available from stock from 0-. Lightweight for easy installation. Plug-in auxiliary control relays available. ASCO 90 Remote Control with sub-panel See Notes Specify Option A and B,,,,,, 8 9, A B C. A maximum of one pair of optional A and B contacts can be supplied on the above indicated remote es.. The Amperage of the neutral plate will be equal to the Amperage of the specified remote. Lugs capable of accommodating the same cables as a single main pole are provided.. When ordering specify desired control voltage. See next page for control voltages.. Control line fuses can be used to supply power from the remote enclosures to external control stations. Any incoming service or control power should have appropriate overcurrent protection at their source as required by application codes. For a grounded control voltage, one fuse should be ordered; for an ungrounded control voltage, two fuses should be ordered.. Shipped loose for open types. Installed for enclosed types.. U.L. recognized.,0, 08, 0, VAC, 0 or, or 0VDC Accessory Three-Wire Control Accessory 8 Catalog A Three-wire ASCO relay for three-wire control.,0, 08, 0, VAC, 0 or,,,, 8 or 0VDC Accessory 8 Dimensions inches (mm) for ASCO two-wire and three-wire Control Relays -/ (mm) (mm) -/8 8 (mm). Dimensional data is approximate and subject to change. Operating Coil Characteristics Accessory Accessory 8 Nominal AC Pickup Voltage AC Nominal DC Pickup Voltage DC Maximum Voltage.0 VA. Watts 80% of Nominal 0% of Nominal.0 VA. Watts % of Nominal 0% of Nominal

5 Maximum reliability and excellent value ASCO 90 Remote Control (RC) es ASCO 90 Remote Control in Type Enclosure The ASCO 90 is designed as a feeder disconnect switch for load capacities beyond the ASCO 9. ASCO 90 RC switches are available for separate mounting in NEMA type enclosures or direct mounting within lighting panelboards for total or splitbus applications. It is available from 0 through Amperes per pole with or poles and service voltages through 00 volts AC. The ASCO 90 is listed under UL 08 for ballast lighting, tungsten, general use and resistive loads. It also ASCO 90 Ordering Information meets the withstand current requirements of UL for panelboard applications. The ASCO 90 is easy to install and features all position mounting, no derating for high inrush loads and a reliable single-solenoid operator. ASCO 90 RC switches can be used with energy management systems which automatically control lighting and power circuits through control devices such as photoelectric cells, microprocessors, timers and occupancy sensors. Product Code of Poles 90 Continuous Ampere UL listed. CSA Approved Meets UL requirements with short-circuit rating (Withstand Current ) of,000 rms symmetrical at 80 volts for use with molded case circuit breakers; 00,000 rms symmetrical at 00 volts for use with currentlimiting fuses. Interrupts 00% of rated current at 80 volts, 0. to 0. power factor ASCO 90 Optional Auxiliary Control Relays Features Voltage Code AC/DC AC Voltage to 0V 08 to 0V to V 0 to 80V 9 Other Voltages Up to 80 X Sub-Panel Code 0 = No Sub Panel = Sub-Panel Enclosures Options Leave Blank for No Options. X Indicates Options. List Separately. See Below. Leave Blank for Open - Type. C Indicates NEMA Type, or Specify Other Type Required.. For DC service, maximum current rating is or switch rating, whichever is less, with maximum voltage rating of volts when connected pole to load and 0 volts when connected poles to the load.. All at 0 or 0 Hz. For voltages other than those listed, and for DC applications, contact your nearest ASCO source.. Specified only when ASCO 90 is to be mounted within a panelboard. A sub-panel is required when mounting in NEMA type enclosures Example: The catalog number for an ASCO 90, -pole, -amp switch with a control coil voltage of volts, 0 Hz, with an Optional Accessory 8 and a sub-panel, in a NEMA Type enclosure is: 90XC with option 8A(0V) Allows control of RC switches directly from energy management systems. UL recognized for use with ASCO RC switches. Permits low voltage AC or DC normal. Polycarbonate dust cover for protection against industrial environment. Barrier screw type terminals with approved means for solderless connection of conductors. Low VA burden. Auxiliary Control Relays to Operate RC es are useful when: When the controlling device does not have adequate current-carrying capacity to directly control the RC switch. When the control station is to be located at a distance greater than the allowable RC switch line run. When the controlling device is only available as a single pole, single throw contact, necessitating a two-wire control line. Narrow width design. Incorporates ASCO relays. When Form (start-stop) control for an RC switch is required. Two-Wire Control Accessory Catalog A0 Two-wire ASCO relay for two-wire control. ASCO 90 Features Electrical Features The largest service organization of its kind Creative, responsive, customer - focused and competitive. Optional Accessories Can be used with metal halide, mercury vapor, quartz halogen, tungsten and fluorescent lighting. No derating when used on high inrush loads such as cold tungsten lamps. Wide arc gaps and arc splitters to quickly extinguish arcs. Isolated arcing chambers are widely spaced and symmetrically located. Construction Features Long life. Designed for more demanding lighting contactor use. Provides extended life and quieter operation. Suitable for use with energy management systems. Rugged molded base and cover with superior electrical insulation. Control line terminal clamps simplify installation: Insert wire and tighten. Wire range # AWG to #0 AWG. Option Description Auxiliary contacts, one normally open and one normally closed. Supplied as a pair. Rated 0 amps at 80 VAC. Fully-rated neutral plate Auxiliary control relay for -wire control Auxiliary control relay for -wire control Auxiliary control relay for Form control Control line fuse: For grounded control voltage (to 00V) For ungrounded control voltage (to 00V) For ungrounded control voltage (0-00V) Contacts are power-driven in both directions for complete dependability. No extra wires or contacts needed to install signal lamps at control stations. Can be mounted in any Provisions for manual position. operation during inspection and maintenance. Available from stock from 0-. Lightweight for easy installation. Plug-in auxiliary control relays available. ASCO 90 Remote Control with sub-panel See Notes Specify Option A and B,,,,,, 8 9, A B C. A maximum of one pair of optional A and B contacts can be supplied on the above indicated remote es.. The Amperage of the neutral plate will be equal to the Amperage of the specified remote. Lugs capable of accommodating the same cables as a single main pole are provided.. When ordering specify desired control voltage. See next page for control voltages.. Control line fuses can be used to supply power from the remote enclosures to external control stations. Any incoming service or control power should have appropriate overcurrent protection at their source as required by application codes. For a grounded control voltage, one fuse should be ordered; for an ungrounded control voltage, two fuses should be ordered.. Shipped loose for open types. Installed for enclosed types.. U.L. recognized.,0, 08, 0, VAC, 0 or, or 0VDC Accessory Three-Wire Control Accessory 8 Catalog A Three-wire ASCO relay for three-wire control.,0, 08, 0, VAC, 0 or,,,, 8 or 0VDC Accessory 8 Dimensions inches (mm) for ASCO two-wire and three-wire Control Relays -/ (mm) (mm) -/8 8 (mm). Dimensional data is approximate and subject to change. Operating Coil Characteristics Accessory Accessory 8 Nominal AC Pickup Voltage AC Nominal DC Pickup Voltage DC Maximum Voltage.0 VA. Watts 80% of Nominal 0% of Nominal.0 VA. Watts % of Nominal 0% of Nominal

6 ASCO is the global leader in power switching and controls ASCO 90 Product Specifications Only (Panelboard Mounting),,. Suitable insulation must be behind switch unit.. Suitable for bus bar mounting. Lugs not supplied.. Dimensional data is approximate and subject to change. -/ (0) 8-/ () -/ (89) 0-00 (.) -/ (0) 9-/ () -/ (89) 0- (.) With Sub-Panel (Panelboard Mounting) NEMA Type Enclosure -/ (0) -/(98) -/8 (98) (0) 8-/() -/ () 8(.) -/ (0) -/(8) -/(00) (0) -/ () (.0) (0) (0.) (.0). Enclosure gutter spaces are based on non-looping of cables within the enclosure. Where cables must be looped within the enclosure, oversize cabinets are available at extra cost. Contact ASCO for complete information. Maximum Voltage s at Rated, Open or Enclosed When Connected Pole to Load VAC 0 VAC VAC When Connected Poles to Load on and Poles to Load on 80 VAC 0 VAC 00 VAC A SCO Power Te chnologies 0 Hanover Road F l o r ham Park, NJ 09 USA A SCO w w w. em er so n n et workpower.com / A SCO w w w. ascoapu.co m. For DC service, maximum current rating is amps or switch rating, whichever is less, with maximum voltage rating of volts when connected pole to load and 0 volts when connected poles to load. Current Values and Recommended Control Circuit Size,, Volts, 0 Hz 0 0 Volts, 0 Hz 8 0 Volts, 0 Hz 80 Volts, 0 Hz. Overcurrent protective device ratings for control circuits should be selected and installed in accordance with the NEC.. This table shows the minimum permissible control circuit fuse size, based on the operating coil s momentary inrush current. 8. ASCO furnished control fuses are rated at. Wire Size for Service and Control Connections 9, AL or CU Terminal Lug Wire Range AWG-MCM / Maximum Distance Between Control Station and One ASCO 90 RC with Source Line Voltage at 90% of Normal of Cable per Terminal Lug Connector Control circuit connections are supplied with terminals accommodate a copper wire range of # AWG to #0 AWG. 0. Service connection for switches on sub-panels are furnished with solderless lugs to accommodate copper or aluminum wire, except on 0 Amp size which is provided with / studs. 0- AWG 0 0 Distance in Feet, 0 Volts, 0 Volts, Volts, If the control device does not have adequate current-carrying capacity to control the switch directly, or the control station is to be located a greater distance from the switch than is allowed in the above table, auxiliary control relays for -wire, or -wire control are available. See optional accessories on inside tab.. For 08 volt system, reduce 0 volt values by %.. For volt system, reduce volt values by %. Emerson Network Power. The global leader in enabling Business-Critical ContinuityTM. AC Power Connectivity Embedded Computing Embedded Power Infrastructure Management & Monitoring Outside Plant DC Power Industrial Power Power ing & Controls EmersonNetworkPower.com Precision Cooling Racks & Integrated Cabinets Services Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. 0 Emerson Electric Co. Publication 0 R September, 0 Printed in the U.S.A.

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1 How to configure Part Numbers: Step : Select Switch Amperage Power Module Switch Rating (Amps) Power Module Switch Catalog No. 30 3 60 6 00 200 2 400 4 Step 2: Select Options Needed 5 Bussmann Power Module

More information

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Optional Standby Power Generator Systems A. Furnish and install automatic transfer switches

More information

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according

More information

ASCO SERIES 185 Power Transfer Switches

ASCO SERIES 185 Power Transfer Switches ASCO SERIES 185 Power Transfer Switches 4-hour protection no matter when trouble strikes ASCO Series 185 Power Transfer Switches An Automatic Transfer Switch helps prevent... Your business or home from

More information

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations Connecting the Power of the Sun DC Disconnects for Solar Photovoltaic Installations DC disconnects for solar photovoltaic installations Solar energy is heating up Interest in renewable energy sources has

More information

Tmax MCCBs. Molded case circuit breakers. Tmax

Tmax MCCBs. Molded case circuit breakers. Tmax Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high

More information

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Submit shop drawings for equipment provided under this section Shop drawings shall indicate: Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,

More information

Owner s Manual. For Automatic Transfer Switch. 100-200 Amp, Service Entrance/Non-Service Entrance

Owner s Manual. For Automatic Transfer Switch. 100-200 Amp, Service Entrance/Non-Service Entrance Owner s Manual For Automatic Transfer Switch 100-200 Amp, Service Entrance/Non-Service Entrance Model Numbers RTST100A3 RTSP100A3 RTST150A3 RTST200A3 RTSP200A3 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED:

More information

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun DC disconnects for solar photovoltaic installations Connecting the power of the sun Solar energy is heating up Interest in renewable energy sources has never been greater, and the fastest growing of these

More information

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a

More information

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to: PREFACE UL developed the Dead-Front Switchboard Marking Guide for code authorities, electric utilities, contractors, installers, users, designers, and other interested parties to aid in understanding deadfront

More information

Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity

Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity Proper Application of 415V Systems in North American Data Centers A White Paper from the Experts in Business-Critical Continuity Introduction Increasing pressure to reduce operating expenses and be more

More information

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2

More information

CHAPTER 2 EXAMPLES AND TABLES

CHAPTER 2 EXAMPLES AND TABLES CHAPTER 2 EXAMPLES AND TABLES COMMENTARY AT 210.20(A) EXCEPTION An overcurrent device that supplies continuous and noncontinuous loads must have a rating that is not less than the sum of 100 percent of

More information

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

Learning Module 13: Panelboards and Switchboards. 101 Basic Series Learning Module 13: Panelboards and Switchboards 101 Basic Series What You Will Learn We ll step through each of these topics in detail: Introduction 4 Definitions 4 Similarities Between Panelboards and

More information

MCC Ratings. Voltage Rating

MCC Ratings. Voltage Rating MCC Ratings In addition to the various ratings of individual components used in motor control centers, the overall ratings of the motor control center must also be considered. Voltage Rating Motor control

More information

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less. PART 1 - GENERAL SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less. RELATED SECTIONS Division 16 Section "Basic Electrical Materials and Methods" for general

More information

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY 7320 Ashcroft, Suite 104 Houston, Texas 77081 p: 713-772-1404 f: 713-772-7360 e: [email protected] www.juicegoose.com 06-06 CONGRATULATIONS

More information

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80 Buck-Boost Transformers Single and Three Phase Potted Buck-Boost Transformers Buck-Boost Applications & Standard Specification... 80 Selecting Buck-Boost Transformers... 81 Single Phase Selection Tables...

More information

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. 2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to

More information

DISCONTINUED PRODUCT. Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert icom-do. User Manual

DISCONTINUED PRODUCT. Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert icom-do. User Manual Infrastructure Management & Monitoring For Business-Critical Continuity Liebert icom-do User Manual TABLE OF CONTENTS 1.0 INTRODUCTION............................... 1 2.0 INSTALLATION...............................

More information

Catalog January. Heavy industrial power applications Motor contactors and starters

Catalog January. Heavy industrial power applications Motor contactors and starters Catalog January Heavy industrial power applications Motor contactors and starters 2006 General contents 0 Heavy Industrial Power Applications Motor Contactors and Starters 1 Contactors and Starters, Type

More information

Cable/Conduit Conversion

Cable/Conduit Conversion Cable/Conduit Conversion Busway can be used in many applications where cable and conduit are more commonly used. The question arises, Why use busway instead of conventional cable and conduit? Benefits

More information

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features Metallic and Non-Metallic Air Conditioning Disconnects A Complete Family of Disconnects with Exclusive Time Saving Features Enclosed Molded Case Disconnect Switch Not-Fusible The preferred molded case

More information

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

Lighting Packages. 230 VAC Fluorescent Enclosure Light: Spec-00581 H763.422.2211 763.422.2600 Electrical Lighting Packages Electrical Lighting Packages PANELITE Enclosure Lights Overview FEATURES Slim profile allows light to be tucked up out of the way for

More information

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811 Instruction Sheet 1-2003 Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811 PURPOSE OF KIT A CCM-T is used to monitor and control an automatic transfer switch. The

More information

Power Supplies 3. SDN-P DIN Rail Series

Power Supplies 3. SDN-P DIN Rail Series SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.

More information

SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL 1.1 SUMMARY A. This section describes the requirements for the installation of Power Monitors and associated

More information

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: Chapter 12 of the Burlington Code of ordinances allows owner occupants of single family homes to do their own wiring if they choose. If you choose to

More information

SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS

SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS PART 1 - GENERAL 1.01 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

What are the basic electrical safety issues and remedies in solar photovoltaic installations? What are the basic electrical safety issues and remedies in solar photovoltaic installations? Presented by: Behzad Eghtesady City of Los Angeles Department of Building and Safety Topics Covered Photovoltaic

More information

GTEC transfer switch open transition

GTEC transfer switch open transition GTEC transfer switch open transition 40-1250 Amp Description The GTEC automatic transfer switch combines reliability and flexibility in a small, economical package for transferring loads between a utility

More information

Contactors Low Voltage

Contactors Low Voltage 00Motor Starters and April 06 Sheet Motor Starters and ContactorsLow Voltage.0- ContactorsLow Voltage Contents Motor Starters and ContactorsLow Voltage Manual Motor Control MS Starter with Hand/Auto......................................-

More information

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE 2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE PAGE 1 OF 5 This Reference provides a very comprehensive list of aspects of a solar PV installation that could be reviewed, clarifying

More information

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D 12 - ELECTRIC SERVICE HANDBOOK SECTION D METER REQUIREMENTS This chapter gives you information on Central Lincoln s metering requirements. It's divided into three sections: General requirements This section

More information

Transfer switch BTPC open, closed or delayed transition

Transfer switch BTPC open, closed or delayed transition Transfer switch BTPC open, closed or delayed transition 150-4000 Amp Description The Cummins Power Generation BTPC series bypass isolation transfer switch combines an automatic transfer switch with a drawout

More information

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, 3 8.25 (210) 16 (407) 5.5 (140) 4 11.125 (283) 16 (407) 5.5 (140)

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, 3 8.25 (210) 16 (407) 5.5 (140) 4 11.125 (283) 16 (407) 5.5 (140) 9-10N Supersedes Selection Data 9-10N, pages, 1-, dated dated March March 1995 1995 Mailed to: E, D, C/9-100A, 31-A, INTERRUPTING CAPACITY RATINGS IEC 947- Interrupting Capacity s➀ Interrupting Capacity

More information

How To Operate A Gec Transfer Switch Open Transition 40 2000 Amp Power Supply

How To Operate A Gec Transfer Switch Open Transition 40 2000 Amp Power Supply GTEC Transfer switch open transition 40 2000 amp Description GTEC transfer switches combine reliability and flexibility in a small, economical package for transferring loads between a utility and a generator

More information

Circuit Breakers Supplementary Protectors Manual Motor Controllers

Circuit Breakers Supplementary Protectors Manual Motor Controllers WHITE PAPER Circuit Breakers Supplementary Protectors Manual Motor Controllers Circuit Protection Methods Differentiating between Supplementary Protection, Branch Circuit Protection, and Self-Protected

More information

THERMAL MANAGEMENT SOLUTIONS

THERMAL MANAGEMENT SOLUTIONS t2000 Series Electronic heat-tracing controller Product Overview /COMMUNICATIONS INTERACE CARRIER REQ TO SEND The DigiTrace heat trace controller is designed to provide the benefits associated with single

More information

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables The National Armored Cable Manufacturers Association Presents Installation Standard for Types AC and MC Cables An ANSI Standard Original document jointly produced by NECA and NACMA as Standard for Installing

More information

Sentron Series Circuit Breakers

Sentron Series Circuit Breakers Sentron Series Circuit Breakers Siemens Sentron Series circuit breakers are available in nine frame sizes: ED, FD, JD, LD, LMD, MD, ND, PD, and RD. Sentron Series circuit breakers have a wide range of

More information

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services Circuit Breakers and Switchgear Thomas Greer Director of Engineering TLG Services Presentation Outline Switchgear Definition Overcurrent Protection Devices Circuit Breaker Trip Curves and Coordination

More information

BRITISH STYLE SEMICONDUCTOR PROTECTION FUSES

BRITISH STYLE SEMICONDUCTOR PROTECTION FUSES The Edison British Style semiconductor protection fuses include a 660VAC line utilizing new filler technology. These new fuses have greatly reduced peak let-through current and energy under fault conditions

More information

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,

More information

NFPA 70E 2012 Rolls Out New Electrical Safety Requirements Affecting Data Centers

NFPA 70E 2012 Rolls Out New Electrical Safety Requirements Affecting Data Centers NFPA 70E 2012 Rolls Out New Electrical Safety Requirements Affecting Data Centers A market position paper from the experts in Business-Critical Continuity TM Executive Summary Electrocutions are the fourth

More information

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS:

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS: RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS: Signed completed Electrical Permit application form. Minnesota law requires all electrical work is to be performed by licensed,

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS VAN AMBATIELOS PRESIDENT E. FELICIA BRANNON VICE-PRESIDENT JOSELYN GEAGA-ROSENTHAL GEORGE HOVAGUIMIAN JAVIER NUNEZ CITY OF LOS ANGELES CALIFORNIA ERIC GARCETTI

More information

Line Loss WSDOT Winter 2008 BZA

Line Loss WSDOT Winter 2008 BZA Electrical Design Training Class Line Loss WSDOT Winter 2008 BZA Presented by: Keith Calais 1 OHM S LAW P = Watts (Power) I = CURRENT (AMPERES) R = RESISTANCE (OHMS) E = ELECTROMOTIVE FORCE (VOLTS) P =

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable

More information

Secondary Unit Substations

Secondary Unit Substations 14 SWITCHGEAR Secondary Unit Substations Overview Siemens offers a wide variety of unit substation designs to meet customer requirements. A unit substation consists of one or more transformers mechanically

More information

E2 Series Electric Furnaces

E2 Series Electric Furnaces E2 Series Electric Furnaces Service Manual Table of Contents Electrical Requirements... 10 Codes, Specifications Requirements... 10 Connection Supply Service Wires... 10 Furnace Sequence of Operation...

More information

Solid State Timers Type F

Solid State Timers Type F Solid State Timers Type F Class 9050 CATALOG CONTENTS Description.....................................................Page Product Descriptions............................................. 3 Application

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

D-Line Contactors, Overload Relays and Accessories

D-Line Contactors, Overload Relays and Accessories D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information...............................................

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information

NEC 2014 Code Changes

NEC 2014 Code Changes NEC 2014 Code Changes Articles 400-408.55 CHANGES FROM 2011 TO 2014 CODE ARE IN RED Chapter 4 Equipment for General Use ARTICLE 400 Flexible Cords and Cables 400.4 Types Flexible cords and flexible cables

More information

Vario-Series Accessories

Vario-Series Accessories Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates

More information

8146/5 Series Breaker Panelboards

8146/5 Series Breaker Panelboards 8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division

More information

MCR1900 Media Converter 19-Slot Chassis

MCR1900 Media Converter 19-Slot Chassis MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the

More information

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET: SWITCH The Budderfly lighting switch is a Decora style, plug-and-play replacement for your existing building switches. Installing a Budderfly adapter transforms your building s existing wiring into the

More information

ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST

ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST Name of School: OPTIONAL INFORMATION Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST Guidelines: This checklist

More information

Thermal-Magnetic / Magnetic Only Molded Case Circuit Breakers

Thermal-Magnetic / Magnetic Only Molded Case Circuit Breakers Thermal-Magnetic / Magnetic Only Molded Case Circuit Breakers Catalog 2004 Class 601 CONTENTS Description..............................................Page INTRODUCTION.............................................

More information

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

ELECTRIC METERING COMMERCIAL & INDUSTRIAL ELECTRIC METERING COMMERCIAL & 1.0 INDEX 1.0 INDEX 2.0 SCOPE 3.0 GENERAL REQUIREMENTS 4.0 METER LOCATIONS 5.0 UNDERGROUND TERMINATIONS 6.0 METERING TRANSFORMER ENCLOSURES 7.0 SINGLE CUSTOMER METER INSTALLATIONS

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to: PREFACE UL has developed the Molded-Case Circuit Breaker (MCCB) Marking Guide for electrical inspectors, electric utilities, contractors, installers, users, designers, and other interested parties to aid

More information

Mission Critical Data Center Systems

Mission Critical Data Center Systems Mission Critical Systems Mission Critical/ Electrical Distribution Systems Data center electrical distribution designs are rapidly evolving, driven by needs such as increasing power densities, energy efficiency,

More information

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS POWER DISTRIBUTION RACKS IN A MISSION CRITICAL SYSTEM MODULES IN A MISSION CRITICAL SYSTEM UPS Convertor Main Inverter Load Battery BPC UPS & BATTERY

More information

Instructions for Class W200, W201, Sizes 5 and 6, Three Phase Non-Reversing Magnetic Motor Starters and Contactors

Instructions for Class W200, W201, Sizes 5 and 6, Three Phase Non-Reversing Magnetic Motor Starters and Contactors I.L. 17405 Revision F Instructions for Class W200, W201, Sizes 5 and 6, Three Phase Non-Reversing Magnetic Motor Starters and Contactors RATINGS The maximum horsepower ratings of these motor controllers

More information

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary

More information

Safetran TYPE ST1 AND ST2 VITAL PLUG-IN RELAYS I-1-1. Relays SIZE 1 AND SIZE 2 READILY MOUNTS TO EXISTING SOCKETS

Safetran TYPE ST1 AND ST2 VITAL PLUG-IN RELAYS I-1-1. Relays SIZE 1 AND SIZE 2 READILY MOUNTS TO EXISTING SOCKETS Safetran I-1-1 TYPE ST1 AND ST2 VITAL PLUG-IN RELAYS SIZE 1 AND SIZE 2 READILY MOUNTS TO EXISTING SOCKETS ALL FERROUS METAL PARTS ARE NICKEL PLATED MEETS OR EXCEEDS APPLICABLE AREMA RECOMMENDED PRACTICES

More information

Single Phase Soft Starter

Single Phase Soft Starter Single Phase Soft Starter Installation & Operating Manual 6/02 Table of Contents Section 1 General Information................................................... 1 1 General Description................................................

More information

Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems

Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems Suitable for Emergency, Peak and Prime Power System Applications Low Voltage Automatic Transfer Switch Systems THE POWER AUTHORITY THE POWER AUTHORITY ASCO s experience and commitment to excellence in

More information

Distribution Dry Type Transformers

Distribution Dry Type Transformers 8 TRASFORMERS Distribution Dry Type Transformers Table (Contact Sales office for List Price) (commonly used) 1a. 115 C Rise F 1b. 80 C Rise B 4. Wall Brackets1 W 6. Low noise XdB below std. LX Type bg

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

Arc Flash Avoidance and its Application to Overhead Traveling Cranes

Arc Flash Avoidance and its Application to Overhead Traveling Cranes Arc Flash Avoidance and its Application to Overhead Traveling Cranes Whitepaper August 2012 Jason Wellnitz, Controls Product Manager Material Handling Numerous technical papers, bulletins, magazine articles

More information

Circuit Breakers. Next Generation of Protection Capabilities

Circuit Breakers. Next Generation of Protection Capabilities Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many

More information

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional

More information

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY! READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY! The main power to any existing system must be disconnected prior to the

More information

Freeze Protection Thermostats MODELS SST 2. Installation and Operation Manual

Freeze Protection Thermostats MODELS SST 2. Installation and Operation Manual Freeze Protection Thermostats MODELS SST 2 Part Number 22744 MANUAL We Manage Heat Installation and Operation Manual Environmental Technology, Inc. 1850 N Sheridan Street South Bend, Indiana 46628 (574)

More information

Tips for connecting 24-volt power

Tips for connecting 24-volt power Digital Designer s Guide Application NoteAN0604D Revision B Tips for connecting 24-volt power This application note covers choosing a transformer and connecting 24 volt AC power to a KMC Controls DDC controller.

More information

Operation and Maintenance manual. fusible shunt trip switch

Operation and Maintenance manual. fusible shunt trip switch Operation and Maintenance manual fusible shunt trip switch Table of Contents Fusible Shunt Trip Switch Device Overview... 2 Installation Instructions... 3 Catalog Number Selection Table... 4 Motor Fuse

More information

CONDUCTOR SHORT-CIRCUIT PROTECTION

CONDUCTOR SHORT-CIRCUIT PROTECTION CONDUCTOR SHORT-CIRCUIT PROTECTION Introduction: This paper analyzes the protection of wire from fault currents. It gives the specifier the necessary information regarding the short-circuit current rating

More information

Primary and Secondary Electrical Distribution Systems

Primary and Secondary Electrical Distribution Systems Primary and Secondary Electrical Distribution Systems Critical Facilities Round Table 12th Quarterly Membership Meeting June 2, 2006 David D. Roybal. P.E. Eaton Electrical Cutler-Hammer Products Utility

More information

PSR The compact range Description

PSR The compact range Description Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides

More information

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations 12S, 14S, 15S Series Time Delay Relays and Sequencers Time Delay Relays and Sequencers The Therm-O-Disc type 12S, 14S and 15S series time delay relays and sequencers are field-proven devices for controlling

More information

13 SERIES. Electronic step relays 10-16 A 13.81 13.91

13 SERIES. Electronic step relays 10-16 A 13.81 13.91 13 Electronic step relays 10-16 A 13 13.81 - Electronic step relay - Rail mount - 1 Pole 13.91 - Electronic step relay and timing step relay Switch box mount - 1 Pole Fixed time (10 minutes) timing function

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide - long al and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide range coils +0% to -30% Finger safe terminals Four-pole versions available NO + NC and

More information

Inverter / Charger Installation General Operations and AC and DC Connections

Inverter / Charger Installation General Operations and AC and DC Connections Inverter / Charger Installation General Operations and AC and DC Connections The Inverter is just one piece. Sometimes, a tendency is to mount the inverter and batteries, and make it work It is better

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

Hyperlinks are Inactive

Hyperlinks are Inactive Prepared by: NIB/EOB PLANNING GUIDE FOR SINGLE CUSTOMER SUBSTATIONS SERVED FROM TRANSMISSION LINES 05503 Department: Electric T&D Section: T&D Engineering and Technical Support Approved by: G.O. Duru (GOD)

More information

INSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD. 2108 LOW VOLTAGE TRACK LIGHTING SYSTEM

INSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD. 2108 LOW VOLTAGE TRACK LIGHTING SYSTEM 7/00 INSTALLATION INSTRUCTION SPEC. SHEET 99052 99063 City of New York Calendar #40747 Copyright c 2000 ALFA Lighting, Inc. All rights reserved. Call:1-415-975-8080 QUICK JACK QJS R LISTED 9901483 ETL

More information

Specification Requirements DBL 700MX and 1000MX Series UPS

Specification Requirements DBL 700MX and 1000MX Series UPS Specification Requirements DBL 700MX and 1000MX Series UPS Theory of Operation Upon loss of utility power, the UPS inverter shall continue to provide seamless pure sine-wave AC from the batteries without

More information

AZ420 MINIATURE GENERAL PURPOSE RELAY

AZ420 MINIATURE GENERAL PURPOSE RELAY MINIATURE GENERAL PURPOSE RELAY FEATURES Rugged construction for high reliability Life expectancy greater than 0 million operations DC coils to 11 V Power consumption as low as 2 mw per pole available

More information

Terminal Blocks 9080LBA Power Distribution Blocks Copper or Aluminum Wire

Terminal Blocks 9080LBA Power Distribution Blocks Copper or Aluminum Wire 9080LBA Power Distribution Blocks Copper or Aluminum Wire Class 9080 Miniature Standard Amperage Rating - CU Wire 115 amp. 115 amp. 175 amp. 175 amp. Amperage Rating - AL Wire 90 amp. 90 amp. 135 amp.

More information

How To Test A Power Switch On A Power Supply

How To Test A Power Switch On A Power Supply transfer switches Soft load Innovative, reliable, integrated solution Built with years of experience Powered with innovation Delivered with reliability A history of experience, innovation and reliability

More information

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5 AMFA-27 AMFA-29 Operator s Manual & Installation Instructions Rev. 2.5 Date: 17 July, 2010 Permanently-connected, utility Interactive, single-phase, inverters Model AMFA-27 WIND TURBINE INVERTER (240 VAC

More information

British BS 88 Fuses. Introduction

British BS 88 Fuses. Introduction British BS 88 Introduction British BS 88 Contents Fuse Volts Amp Range Page 0-900 188-190 90-791-19 Accessories Indicator System & Fuse Bases 195 British BS 88 Fuse Ranges Amps Vac Vdc -900 0 150-710 90

More information