Agilent J&W DB-WAX Ultra Inert GC columns INCREASE YOUR ANALYTICAL CONFIDENCE FOR CHALLENGING POLAR COMPOUNDS
|
|
|
- Frederick Hall
- 9 years ago
- Views:
Transcription
1 Agilent J&W DB-WAX Ultra Inert GC columns INCREASE YOUR ANALYTICAL CONFIDENCE FOR CHALLENGING POLAR COMPOUNDS
2 AGILENT J&W DB-WAX ULTRA INERT GC COLUMNS NOW YOU CAN ACHIEVE BETTER PEAK SHAPE AND REPRODUCIBILITY FOR CHALLENGING POLAR COMPOUNDS GC columns with Polyethylene glycol (PEG) stationary phases are commonly used for analyzing compounds with polar functional groups. They are well suited for food, flavor, and fragrance applications, as well as industrial chemical analysis in quality control and method development labs. For active and complex polar compounds, you cannot afford adsorption caused by flow path activity. Having to repeat or verify suspect analyses wastes valuable resources, hinders productivity, and hurts your bottom line. Unreliable results can also have serious implications in the quality of the foods we eat and the products that consumers and businesses use every day. Perform worry-free analysis of polar compounds with NEW Agilent J&W DB-WAX Ultra Inert GC columns With their Durabond Polyethyleneglycol stationary phase and proprietary processing, DB-WAX Ultra Inert GC columns deliver excellent inertness with greater sensitivity than any other WAX column on the market. These innovative columns let you: Spend less time on troubleshooting and reruns: With DB-WAX UI GC columns, you can count on excellent peak shape and column-to-column inertness reproducibility, as well as retention time stability. Save money on columns and maintenance: DB-WAX UI has extended inertness lifetime that withstands repeated temperature cycling to the upper temperature limits of the column. Stop wasting time prequalifying columns: Specific inertness testing during quality control guarantees out-of-the-box inertness performance for every DB-WAX UI column. Implement easily, with minimal workflow interruption: DB-WAX UI GC columns have the same selectivity as DB-WAX GC columns. This makes upgrading to Ultra Inert performance easy with minimal validation. What s more, there s no need to recreate or modify existing compound libraries that are based on DB-WAX selectivity.
3 Trust Ultra Inert GC columns for your trace-level analysis of active analytes DB-WAX UI GC columns are part of the Agilent J&W Ultra Inert GC column family, which pushes industry standards for consistent column inertness. Every Ultra Inert GC column is rigorously tested to ensure optimal active analyte delivery to the GC or MS detector. The result: optimal, lower detection limits and more accurate identification of challenging polar analytes. Proof of inertness: the DB-WAX Ultra Inert test mix A strong test probe mixture can highlight deficiencies in column activity, while a weak mixture can actually mask such deficiencies. Like all of Agilent's Ultra Inert GC columns, DB-WAX UI GC columns are tested with the industry s most demanding test probe mixture based on real-world requirements and we prove it with a performance summary sheet shipped with each column. In addition, the DB-WAX Ultra Inert test probe mixture includes decanal, propionic acid, ethyl hexanoic acid, and ethyl maltol to ensure inertness performance for these active polar compounds. DB-WAX Ultra Inert test mix mau min DB-WAX Ultra Inert QC test mix contains strong inertness probes including decanal, propionic acid, -ethylhexanoic acid and ethyl maltol to ensure consistent inertness for challenging flavor compounds.. -Nonanone Decanal. Propionic Acid. Ethylene Glycol. Heptadecane. Aniline Carrier Gas: cm/s Injection: µl, C Oven: Detector:. Methyl Dodecanoate. -Chlorophenol. -Undecanol. Nonadecane. -Ethylhexanoic Acid. Ethyl Maltol C Isothermal FID, C, H ml/min, Air ml/min, N make-up gas ml/min For more information, or to order now, visit
4 APPLICATIONS EXCELLENT PEAK SHAPE FOR ACIDIC COMPOUNDS With DB-WAX UI GC columns, there is no need to run a separate FFAP column. You can standardize on DB-WAX UI to broaden your application range. Competitive comparison: free fatty acids DB-WAX Ultra Inert GC column m x. mm id,. μm (p/n -UI) mau mau..... min Standard WAX GC column m x. mm id,. μm The DB-WAX UI GC column exhibits excellent peak shape for this mixture of free fatty acids, compared to a standard WAX capillary column. min. Methane. Acetone (solvent). Acetic Acid. Propionic Acid. Isobutyric Acid. Butyric Acid. Isovaleric Acid. Valeric Acid. -Methylvaleric Acid. Hexanoic Acid. -Methylhexanoic Acid. -Ethylhexanoic Acid. Heptanoic Acid. Pyruvic Acid. Octanoic Acid. Nonanoic Acid. Decanoic Acid. Undecylenic Acid. Myristic Acid (Tetradecanoic) Carrier gas: Injection volume: μl cm/s Inlet: C Oven program: Detector: C Isothermal C, H ml/min, Air ml/min, N make-up gas ml/min
5 Competitive Comparison: Stability at T max DB-WAX Ultra Insert vs. StabilWAX and ZB-WAX plus Inertness of Agilent DB-WAX UI pa XOffset : YOffset :.. DB-WAX UI after h at ºC DB-WAX UI after h at ºC.... Even after hours of exposure at the upper temperature range, the DB-WAX UI GC column demonstrated superior inertness and stability with minimal peak shifting. Inertness of Restek StabilWAX pa Inertness of Phenomenex ZB-WAX plus pa XOffset : YOffset : StabilWAX after h at ºC StabilWAX after h at ºC.... RT [min] XOffset : YOffset : ZB-WAX plus after h at ºC ZB-WAX plus after h at ºC.... RT [min]. -Nonanone. Decanal. Propionic Acid. Ethylene Glycol. Heptadecane. Aniline. Methyl Dodecanoate. -Chlorophenol. -Undecanol. Nonadecane. -Ethylhexanoic Acid. Ethyl Maltol Injector: C, Split : Injection volume: µl Flow rate:. ml/min, H gas Oven program: C Isothermal Detector: C Application Note: Application Note: A New PEG GC Column with Improved Inertness Reliability and Column Lifetime (-EN)
6 APPLICATIONS STABLE INERTNESS PERFORMANCE FOR ALCOHOLS AND GLYCOLS Glycol (diol) compounds are commonly used in the manufacturing of consumer and industrial products, such as cosmetics, polyesters, paints, automotive coolant, cleaning solutions, and wood finishes. For these challenging compounds, Agilent J&W DB-WAX Ultra Inert GC columns deliver inertness and longevity, while maintaining DB-WAX selectivity. Analysis of diethylene glycol (DEG) and ethylene glycol (EG) in toothpaste DB-WAX UI "Brand R" WAX ms th injection th injection th injection th injection ,-propanediol. EG.,-Propanediol. DEG. Glycerin DB-WAX UI GC columns meet strict analytical standards for detecting trace levels of diethylene glycol (DEG) and ethylene glycol (EG) known poisons that are commonly used as industrial solvents and in antifreeze solutions. Column: DB-WAX UI, m x. mm,. µm (p/n -UI) Tubing: Instrument: Injection volume: µl Carrier gas: Agilent Ultimate Plus deactivated FS tubing, m x. mm (p/n CP) Agilent B autosampler and sample tray, µl syringe (p/n G-) Helium, cm/s constant flow mode Inlet: C, split ratio : Oven program: MSD: Solvent delay: C ( min) to C at C/min, min hold Agilent A MSD min MS temperature: C (source), C (quad) Transfer line: C, EI Scan - amu, EI mode Scan - amu Application Note: Analysis of Glycols in Toothpaste Using Agilent J&W DB-WAX Ultra Inert Capillary GC Column (-EN)
7 Inertness comparison: DB-WAX Ultra Inert outperforms "Brand G" Inertness of DB-WAX UI column: Alcohols and Glycols test mix mau mau FID B, Back Signal (E:\DATA\UIWAX\B IEX.D), Inertness of "Brand G" WAX column: Alcohols and Glycols test mix, min *, min *,* *,* *,* * *,* The DB-WAX UI column shows superior performance, compared to the Brand G WAX column, for an extensive list of Alcohols and Glycols.. Methane. Acetone (solvent). Methyl Alcohol. tert-butyl Alcohol. Isopropyl Alcohol. Ethyl Alcohol. tert-amyl Alcohol. n-propyl Alcohol. Isobutyl Alcohol. -Methyl--pentanol. n-butyl Alcohol. -Methyl--pentanol (Methyl amyl alcohol). -Methoxyethanol (Ethylene glycol monoethyl ether). -Methyl--butanol (Isoamyl alcohol). -Ethoxyethanol (Ethylene glycol ethyl ether). Cyclopentanol. -Hexanol (n-hexyl alcohol). Cyclohexanol. -Butoxyethanol (Ethylene glycol monobutyl ether). -Heptanol (n-heptyl alcohol). Propylene glycol (,-Propanediol). -(-Ethyoxyethoxy)ethanol (Diethylene glycol monoethyl ether). -Methyl-,-pentanediol (Hexylene glycol). Ethylene glycol (,-Ethanediol, Gycol). -Nonanol (n-nonyl alcohol). Glycerol formal ( isomers).,-propanediol (Trimethylene glycol). Neopentyl glycol (,-Dimethyl-,-propanediol). Dipropylene glycol (* of isomers).,-hexanediol ( isomers). -Undecanol (Undecyl alcohol).,-pentanediol. Dipropylene glycol (* of isomers).,-hexanediol. Dipropylene glycol (* of isomers). Diethylene glycol (-Oxa-,-pentanediol).,-Pentanediol (Pentylene glycol). -Tridecanol (n-tridecyl alcohol). -Methyl-,-pentanediol. Methyl neopentyl glycol (,-Dimethyl-,-propanediol). -Pentadecanol (n-pentadecyl alcohol). Anisyl alcohol ((-Methyoxyphenyl)methanol). Glycerol (Glycerine, Glycerin, Propanetriol). Triethylene glycol (Triglycol).,-Octanediol (Octamethylene glycol).,-butanediol (Tetramethylene glycol).,-nonanediol (Nonamethylene glycol).,-decanediol (Decamethylene glycol). Steary alcohol (-Octadecanol, n-octadecyl alcohol). Tetraethylene glycol (Tetraglycol) Column: Oven program: Carrier gas: Injection volume: µl Inlet: Split C Detector: DB-WAX UI m x. mm id,. µm (p/n -UI) C (. min), C/min to C, min hold ml/min constant flow C, H ml/min, Air ml/min, N make-up gas ml/min Flow path supplies: Ultra Inert Low Pressure drop liner (p/n -) Ultra Inert gold seal (p/n -) Self Tightening Column Nut (p/n -) Graphite-vespel ferrules (p/n -) pk Long-life septa (p/n -)
8 APPLICATIONS RELIABLE, ROBUST PERFORMANCE FOR AQUEOUS SAMPLES Agilent J&W DB-WAX Ultra Inert GC columns deliver extended longevity and a lower cost per analysis for beverages/spirits, glycols in water, and headspace applications. The bonded and cross-linked DB-WAX UI phase is solvent rinsable, and tolerates aqueous injections. Profile of Maker s Mark Whiskey pa *FID A, Front Signal (a -- --\F.D) *FID A, Front Signal (a -- --\F.D) Retention time and peak shape remained stable over injections of neat -proof whiskey. th injection st injection min. Acetyl aldehyde. Ethyl acetate. Methanol. Ethanol. -propanol. Isobutyl alcohol. methyl -butanol/ methyl -butanol. Acetic acid. Phenyl ethyl alcohol Column: DB-WAX UI m x. mm x. µm (p/n -UI) Injection volume:. μl Inlet: Split C Inlet liner: Carrier gas: Oven program: Detector: C Ultra Inert Low Pressure drop liner with wool (p/n -) H constant flow. ml/min C, min hold, C/min to C, min hold Application Note: Analysis of Distilled Spirits Using Agilent J&W DB-WAX Ultra Inert Capillary GC Column (-EN)
9 Bonded PEG stationary phase capillary columns are specified in numerous ASTM methods. These include the separation of isomeric solutes, as well as fast resolution of non-polar saturated hydrocarbons from polar solutes in complex process streams. Stringent Agilent testing procedures give you the confidence that every DB-WAX UI GC column you install will meet the industry s most demanding performance specifications. Analysis of BTEX pa pa DB-WAX UI DB-WAX min min. n-nonane. benzene. toluene. n-undecane(is). ethylbenzene. p-xylene. m-xylene. cumene. o-xylene Identical selectivity enables easy standardization of DB-WAX UI for BTEX and other industrial solvents. Columns: Injection volume:. μl DB-WAX UI m x. mm x. μm (p/n -UI) DB-WAX m x. mm x. μm (p/n -) Inlet: Split C Carrier gas: Oven program: Detector: C ml/min (constant flow) C for min to C/min and min hold
10 UPGRADE EASILY UPGRADE DB-WAX METHODS FOR BETTER QUALITATIVE AND QUANTITATIVE RESULTS DB-WAX methods containing active compounds (such as alcohols, carboxylic acids, and aldehydes) can easily be switched to Agilent J&W DB-WAX Ultra Inert GC columns without modifying your existing methods and retention time libraries. Identical selectivity specifications and operating temperatures simplify validation, and allow you to standardize methods for improved efficiency. Extended FAMEs mix: compounds, retention time locked for Methyl Stearate (nc:) mau a b a b,,,,,,,,,, b,, a,, DB-WAX UI,,b, a a b DB-WAX Column: DB-WAX UI m x. mm id,. μm (p/n -UI) Inlet: C (p/n GA), split ratio : Injection volume: µl Carrier gas: Head pressure: Oven program: Detector: Hydrogen Methyl Stearate is retention time locked at. min. Carrier gas pressure set to constant pressure mode, velocity approximately cm/s at ºC and kpa C, min, C/min to C, min to C, min hold C, H ml/min, Air: ml/min, He make-up gas: ml/min Flow path supplies: Ultra Inert Low Pressure drop liner (p/n -) Ultra Inert gold seal (p/n -) Self Tightening Column Nut (p/n -) Graphite-vespel ferrules (p/n -) pk Long-life septa (p/n -) mau DB-WAX Ultra Inert has the same selectivity as DB-WAX as demonstrated with this separation of FAME compounds. Agilent leads the food analysis industry with products and services to help you deliver what your customers demand. We provide entire analytical workflow solution from sample preparation, to instruments, supplies, and powerful software that are used throughout the food production chain, including incoming inspection, new product development, quality control and assurance, and packaging. For more information, visit the Agilent Food Solution website today at
11 Lavender oil sample: Identical retention performance of DB-WAX and DB-WAX UI is demonstrated with this separation of lavender oil. pa DB-WAX Column: DB-WAX UI, m x. mm,. µm (p/n -UI) and DB-WAX, m x. mm,. µm (p/n -) Instrument: Injection volume: µl Agilent B autosampler and sample tray, µl syringe (p/n G-), Carrier gas: Helium, constant flow mode RTL: D-Limonene locked to. min DB-WAX UI min Inlet: C, split ratio : Oven program: C ( min), C/min to C ( min), C/min to C, min hold MSD: Agilent A MSD, solvent delay. min, C (source), C (quad) Expanded view Improved response for terpene, terpine-ol and sesquiterpene compounds. Camphor. b-linalool. Linalool acetate. a-santalene DB-WAX DB-WAX UI. Bornyl acetate. a-bergamotene. Caryophyllene. Terpinen--ol. Lavandulyl acetate. b-farmesene. Lavandulyl. a-terpineol Transfer line: Flow path supplies: Application Note: C, EI mode Scan - amu Ultra Inert Low Pressure drop liner (p/n -) Ultra Inert gold seal (p/n -) Self Tightening Column Nut (p/n -) Graphite-vespel ferrules (p/n -) pk Long-life septa (p/n -) Analysis of Lavender Essential Oil by Agilent J&W DB-WAX Ultra Inert Capillary GC Columns (-EN) Compared with DB-WAX columns, DB-WAX UI columns have the same selectivity, which means no additional method development or validation is needed when replacing DB-WAX with DB-WAX UI. What analysts are saying " With DB-WAX UI, we are seeing better reproducibility of total aldehyde content and less tailing because of the improved inertness. [There is] no selectivity change compared to the standard DB-WAX, which is essential for complex citrus oil analysis. In addition, time spent for pre-testing new columns is eliminated. - DR. ANDREAS BÖKER, MCI MIRITZ CITRUS
12 UPGRADE SUCCESS STORY: AROMA ANALYSIS WAX columns are commonly used for aroma and flavor profiling of foods and beverages. Aroma analysis often involves complex mixtures of compounds in a wide range of concentrations. In the examples below, the DB-WAX UI columns provided optimum response for real-world samples. (Chromatograms courtesy of Dr. Frank David, Research Institute for Chromatography, Belgium.) Tea Aroma on DB-WAX UI x TIC Scan thee.d Counts vs. Aquisition Time (min). Butane,,-diethoxy-. Butane,,-diethoxy--methyl-. -Hexenal. -Hexenal diethyl acetal, trans. -Heptanol, -methyl-. -Pentanone, -hydroxy--methyl-..alpha.-methyl-.alpha. -[-methylpentyl]oxiranmethanol..alpha.-methyl-.alpha. -[-methylpentyl]oxiranmethanol. -Buten--ol, TMS derivative. -Furanmethanol, -ethenyltetrahydro-.alpha.,.alpha.,-trimethyl-, cis-. trans-linalool oxide (furanoid). Nonane,,-diethoxy-. Linalool. -Cyclohexen--ol, -methyl--(-methylethyl)-, (R)-.,,-Trimethyl--cyclohexene-,-dione. Methyl salicylate. -Cyclopenten--one, -methyl--(-pentenyl)-, (Z)- Coffee Aroma on DB-WAX UI x TIC Scan KOFFIE.D Counts vs. Aquisition Time (min). Dimethylketol. Ethyl -hydroxy-propanoate. Trimethyl-pyrazine. Acetic acid. Butyric acid. Caproic acid. Triacetin Column: DB-WAX UI, m x. mm id,. µm (p/n -UI) Injection volume: µl split C Liner: Ultra inert liner (p/n -) Oven program: Carrier: MS: ºC ( min) to ºC/min to ºC ( min) ml/min He constant Scan (- amu)
13 ORDERING INFORMATION Which Ultra Inert GC column is best for your application? High Polar Mid Polar Non/Low Polar DB-WAX UI DB-ms UI DB- UI DB-ms UI HP-ms UI DB-ms UI HP-ms UI Application specific Ultra Inert columns: DB-UI D: Environmental semivolatiles DB-Select UI for : Pharmaceutical residual solvents Need more help? Use the Agilent J&W GC Column Selection Tool to find the right column in just a few clicks: Ultra Inert DB-WAX GC columns ID (mm) Length (m) Film (µm) Part No. DB-WAX Ultra Inert.. -UI. -UI.. -UI.. -UI. -UI. -UI. -UI. -UI.. -UI. -UI. -UI. -UI. -UI.. -UI. -UI. -UI. -UI. -UI Learn how to optimize your flow path for inertness, so you can achieve the parts-per-billion or parts-per-trillion detection levels that today s analyses demand. See our complete line of Ultra Inert GC columns: Download our Inert Flow Path brochure: Download our GC consumables catalog:
14 INERT FLOW PATH AN INTEGRATED APPROACH TO INERTNESS: THE AGILENT ADVANTAGE Flow path inertness is vital to your analysis and is also on the cutting edge of GC By minimizing activity along every step of the GC and GC/MS flow path, Agilent Inert Flow Path solutions improve system performance, ensure better results, and allow you to process more samples without unplanned maintenance and recalibration. So, you won t miss a thing in your GC analysis. Agilent Ultra Inert liners and gold seals Agilent UltiMetal Plus Flexible Metal ferrules Agilent Self Tightening Column Nut Long life septa Sample Ultra Inert liner Glass wool Ultra Inert gold seal Self Tightening Column Nut Inert Flow Path Split/Splitless inlet Agilent J&W Ultra Inert GC column Ultimate plus deactivated guard column/ retention gap UltiMetal Plus Flexible Metal ferrule UltiMetal Plus Ultimate union or device with Flexible Metal ferrule Stationary phase Fused silica surface Deactivation Inside GC Column Polyimide outer coating Detector Self Tightening Column Nut GC/MSD or other detectors whose metal surfaces are treated to improve sensitivity for active analytes (FPD and TCD) Data Ion source Self Tightening Column Nut For more information, visit UltiMetal Plus Flexible Metal ferrule Backflush using -way purged splitter (Capillary Flow Technology device)
15 SUPPLIES AND SERVICES ENSURE A LIFETIME OF INSTRUMENT PERFORMANCE WITH AGILENT SUPPLIES AND SERVICES Accurate, reliable results with fewer repeated samples Agilent sample preparation products help you move easily from sample to successful analytical results: Extend instrument performance with Captiva filtration Reduce costs and save time with Bond Elut QuEChERS kits Achieve lower detection limits with Bond Elut silica and polymeric SPE products Selectively remove lipids in complex matrices with Enhanced Matrix Removal (EMR) Maintain maximum instrument protection The Agilent Gas Clean Filter System delivers clean gases, reducing the risks of column damage, sensitivity loss, and instrument downtime: Deliver clean gases for accurate analyses Fast, leak-free filter replacement reduces downtime Economical, with immediate payback Highly sensitive filter indicators provide maximum instrument protection Solve problems quickly, increase uptime, and optimize resources Whether you need support for a single instrument or a multi-lab, multi-vendor operation, Agilent helps maximize the value of your investment with: Repair and maintenance services Remote advisor support Service plans to suit your needs Compliance support Enterprise services
16 Learn more about Agilent J&W DB-WAX Ultra Inert GC columns Learn how to boost your GC workflow productivity, running more analyses in less time Buy online Download additional application examples Find a local Agilent customer center in your country USA and Canada --- [email protected] Europe [email protected] Asia Pacific [email protected] This information is subject to change without notice. Agilent Technologies, Inc. Printed in the USA March, -EN
Lavender Oil Analysis Using Agilent J&W DB-WAX Ultra Inert Capillary GC Columns
Lavender Oil Analysis Using J&W DB-WAX Ultra Inert Capillary GC Columns Application Note Flavors and Fragrances Author Yun Zou Technologies Ltd, Shanghai Abstract Lavender essential oil samples were analyzed
An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.
An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols. Jaap de Zeeuw, Ron Stricek and Gary Stidsen Restek Corp Bellefonte, USA To analyze basic compounds at
1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.
Standard Method for Analysis of Benzene and Toluene Content in Hydrocarbon Waxes by Headspace Gas Chromatography EWF METHOD 002/03 (Version 1 Reviewed 2015) 1 Scope 1.1 This test method covers the qualitative
Gas Chromatography Liner Selection Guide
Gas Chromatography Liner Selection Guide Peter Morgan, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20551 Key Words Liner, focus Abstract The liner serves an important function in allowing
23 The Thermal Conductivity Detector
23 The Thermal Conductivity Detector General Information TCD pneumatics Conditions that prevent the detector from operating Filament passivation Carrier, reference, and makeup gas Negative polarity Analyzing
Addressing the World Helium Shortage For Gas Chromatography
Addressing the World Helium Shortage For Gas Chromatography Helium Conservation and Converting GC Methods to Nitrogen and Hydrogen Carrier Gas James D. McCurry, Ph.D. Senior Scientist Agilent Technologies
Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS
Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS UCT Part Numbers: ECQUEU750CT-MP - QuEChERS, Mylar packs containing 4 g magnesium sulfate, 1 g sodium chloride, 0.5 g sodium citrate dibasic
The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port
APPLICATION NOTE Gas Chromatography/ Mass Spectrometry Authors: Andrew Tipler Sheila Eletto PerkinElmer, Inc. Shelton, CT The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory
Analyzing Small Molecules by EI and GC-MS. July 2014
Analyzing Small Molecules by EI and GC-MS July 2014 Samples Appropriate for GC-MS Volatile and semi-volatile organic compounds Rule of thumb,
PLOT Columns. Top: Bob Langford, GC Column Manufacturing Technician Bottom: Stephanie Sunner, Customer Service Representative
PLOT Columns Top: Bob Langford, GC Column Manufacturing Technician Bottom: Stephanie Sunner, Customer Service Representative PLOT Column Selection 93 Features & Benefits of Restek PLOT Columns Features
Intelligent use of Relative Response Factors in Gas Chromatography-Flame Ionisation Detection
52 May/June 2012 Intelligent use of Relative Response Factors in Gas Chromatography-Flame Ionisation Detection by Karen Rome and Allyson McIntyre, AstraZeneca, Macclesfield, SK10 2NA, UK Quantitative analysis
Expectations for GC-MS Lab
Expectations for GC-MS Lab Since this is the first year for GC-MS to be used in Dr. Lamp s CHEM 322, the lab experiment is somewhat unstructured. As you move through the two weeks, I expect that you will
ADVANCEMENTS IN MICRO GAS CHROMATOGRAPHY (GC)
ADVANCEMENTS IN MICRO GAS CHROMATOGRAPHY (GC) 1 Fast Analysis of C1 to C8 hydrocarbons for mud logging applications within 2 minutes using a temperature programmable Micro GC Fusion NEN GAS2015 Debbie
Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography
Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography INTRODUCTION The analysis of soft drinks for caffeine was able to be performed using UV-Vis. The complex sample
Identification of Arson Accelerants by Gas Chromatography
Identification of Arson Accelerants by Gas Chromatography Purpose Arson is an insidious crime that annually claims the lives of hundreds of Americans and costs billions of dollars. 1 Scientists and criminal
Gas Chromatograph GC Consumables. p/n: 220-94898-02
Gas Chromatograph GC Consumables p/n: 220-94898-02 Diag. # 1) Septum Nut 2) Needle Guide 3) Septum 4) Injection Port A Assy 5) O-ring for Glass Insert 6) Glass Insert 7) Gold Gasket 8) Capillary Adaptor
Background Information
1 Gas Chromatography/Mass Spectroscopy (GC/MS/MS) Background Information Instructions for the Operation of the Varian CP-3800 Gas Chromatograph/ Varian Saturn 2200 GC/MS/MS See the Cary Eclipse Software
Analysis of Liquid Samples on the Agilent GC-MS
Analysis of Liquid Samples on the Agilent GC-MS I. Sample Preparation A. Solvent selection. 1. Boiling point. Low boiling solvents (i.e. b.p. < 30 o C) may be problematic. High boiling solvents (b.p. >
Chemical Analysis. Natural Gas Analyzer. A Family of optimized GC Solutions. Gas Chromatography. think forward
Chemical Analysis Natural Gas Analyzer A Family of optimized GC Solutions think forward Gas Chromatography Bruker Natural Gas Analyzers Natural gas is bought and sold as a bulk commodity with price based
Chapter 12 Organic Compounds with Oxygen and Sulfur
Chapter 12 Organic Compounds with Oxygen and Sulfur 1 Alcohols An alcohol contains a hydroxyl group ( OH) that replaces a hydrogen atom in a hydrocarbon. A phenol contains a hydroxyl group ( OH) attached
Copyright 2010 Pearson Education, Inc. Chapter Fourteen 1
An alcohol has an OH bonded to an alkyl group; a phenol has an OH bonded directly to an aromatic ring; and an ether has an O bonded to two organic groups. Chapter Fourteen 1 Ethyl alcohol, dimethyl ether,
Theory and Instrumentation of GC Introduction
Theory and Instrumentation of GC Introduction i Wherever you see this symbol, it is important to access the on-line course as there is interactive material that cannot be fully shown in this reference
Agilent Enhanced Matrix Removal Lipid LOSE THE LIPIDS, FIND YOUR ANALYTES
Agilent Enhanced Matrix Removal Lipid LOSE THE LIPIDS, FIND YOUR ANALYTES AGILENT ENHANCED MATRIX REMOVAL LIPID ARE LIPIDS WEIGHING YOUR SAMPLES DOWN? Interference from lipids is a problem for labs measuring
GC/MS Analysis of Vanillin and Ethyl Vanillin in Distilled Spirits
Issue Implementation Page 1 of 7 GC/MS Analysis of Vanillin and Ethyl Vanillin in Distilled Spirits Scope and Application This method will determine the level of vanillin and ethyl vanillin in distilled
SEPARATION AND IDENTIFICATION OF BLOOD POLLUTANTS
SEPARATION AND IDENTIFICATION OF BLOOD POLLUTANTS EBERHARDT KUHN, MEERA DATTA, and JASON ELLIS Agilent Technologies Inc. 91 Blue Ravine Rd. Folsom, CA 95630 INTRODUCTION With the high level of alcohol
LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research
LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research J. Jones, J. Denbigh, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 20581 Key Words SPE, SOLA,
RAPID MARKER IDENTIFICATION AND CHARACTERISATION OF ESSENTIAL OILS USING A CHEMOMETRIC APROACH
RAPID MARKER IDENTIFICATION AND CHARACTERISATION OF ESSENTIAL OILS USING A CHEMOMETRIC APROACH Cristiana C. Leandro 1, Peter Hancock 1, Christian Soulier 2, Françoise Aime 2 1 Waters Corporation, Manchester,
Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.
Gas Chromatography Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC. Samples in 10mL sealed glass vials were placed in the MPS-2
A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water
A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water Sjaak de Koning 1, Mark van Lieshout 2, Hans-Gerd Janssen 2 and Wil van Egmond 1 1 ATAS, De Run 4334, PO Box
Fractional Distillation and Gas Chromatography
Fractional Distillation and Gas Chromatography Background Distillation The previous lab used distillation to separate a mixture of hexane and toluene based on a difference in boiling points. Hexane boils
Quantitative Evaluation of Perfume Fleuressence Samples using the znose
Quantitative Evaluation of Perfume Fleuressence Samples using the znose Edward J. Staples, Electronic Sensor Technology Electronic Noses Conventional electronic noses (enoses) produce a recognizable response
EPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer. HT3 Application Note.
EPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer HT3 Application Note Introduction The analysis of dissolved gases in ground water is important in
Alcohols. Copyright 2009 by Pearson Education, Inc. Copyright 2009 Pearson Education, Inc. CH 3 CH 2 CH 2 OH 1-propanol OH
Chapter 12 rganic Compounds with xygen and Sulfur 12.1 Alcohols, Thiols, and Ethers Alcohols An alcohol contains a hydroxyl group ( ) attached to a carbon chain. A phenol contains a hydroxyl group ( )
Bringing Innovations to Standards AC Analytical Controls by PAC All In One Biodiesel Analyzer
Bringing Innovations to Standards AC Analytical Controls by PAC All In One Biodiesel Analyzer www.paclp.com Background Biodiesel offers an alternative to fossil diesel fuel & contributes to the reduction
Analyzing Alcoholic Beverages by Gas Chromatography
Technical Guide Analyzing Alcoholic Beverages by Gas Chromatography Inside: Analysis of alcohols and aldehydes in alcoholic beverages Flavor compounds in distilled liquor products Determining trace sulfur
ALLERGENS IN PERFUMES: GAS CHROMATOGRAPHY^ MASS SPECTROMETRY
1974 III / ALLERGENS IN PERFUMES: GAS CHROMATOGRAPHY^MASS SPECTROMETRY ALLERGENS IN PERFUMES: GAS CHROMATOGRAPHY^ MASS SPECTROMETRY S. C. Rastogi, National Environmental Research Institute, Rokilde, Denmark
AppNote 10/2012. Large Volume Injection with GC/MS Multi Column Switching for Direct Determination of Ethyl Carbamate in Alcoholic Beverages KEYWORDS
AppNote 10/2012 Large Volume Injection with GC/MS Multi Column Switching for Direct Determination of Ethyl Carbamate in Alcoholic Beverages T. Albinus, K. MacNamara Gerstel GmbH & Co. KG, Eberhard-Gerstel-Platz
Transformer Oil Gas Analysis
Get on the Analyzer FAST TRACK Transformer Oil Gas Analysis Helping customers protect the environment! 1 Why Analyzers Value to Customers Alleviates Resource Pressure Facilitates Configuration Use Advanced
Lecture Chromo-3: Gas Chromatography. CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography. Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder
Lecture Chromo-3: Gas Chromatography CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder Outline Introduction Instrument overview Carrier gas Sample
The Agilent 7890A Gas Chromatograph All the elements for perfect chemistry. Our measure is your success.
The Agilent 7890A Gas Chromatograph All the elements for perfect chemistry. Our measure is your success. Introducing the Agilent 7890A Gas Chromatograph. Step up to a higher level of GC reliability, productivity
GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE
ACTA CHROMATOGRAPHICA, NO. 13, 2003 GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE A. Pavlova and R. Ivanova Refining and Petrochemistry Institute, Analytical Department, Lukoil-Neftochim-Bourgas
Strategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM. Technical Overview.
Strategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM Technical Overview Introduction The 5975A and B series mass selective detectors (MSDs) provide
THERMAL DESORPTION. Introduction and Principles. Focusing on Volatiles
THERMAL DESORPTION Introduction and Principles Thermal Desorption Thermal desorption is a simple extension of the technique of gas chromatography (GC) It involves the use of heat and a flow of inert gas
Separation of Amino Acids by Paper Chromatography
Separation of Amino Acids by Paper Chromatography Chromatography is a common technique for separating chemical substances. The prefix chroma, which suggests color, comes from the fact that some of the
Gerhard Schomburg. Gas Chromatography. A Practical Course. -«WTM-JY// ^ Weinheim New York. VCH XJ Basel Cambridge
Gerhard Schomburg Gas Chromatography A Practical Course -«WTM-JY// ^ Weinheim New York VCH XJ Basel Cambridge Contents 1 The Role of Gas Chromatography Among Other Methods of Instrumental Analysis 1 2
Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS
Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS Stephen Lock 1 and Matthew Noestheden 2 1 AB SCIEX Warrington, Cheshire (UK), 2 AB SCIEX Concord, Ontario (Canada) Overview A rapid,
Split / Splitless Injection for Capillary GC
Split / Splitless Injection for Capillary GC Speakers John V Hinshaw CHROMacademy GC Dean GC Connections editor Moderator Tony Taylor CHROMacademy Trainer Technical Director, Crawford Scientific Dave Walsh
Purification of reaction mixtures using flash chromatography.
Purification of reaction mixtures using flash chromatography. This technical note details the use of ISOLUTE Flash chromatography columns for the purification of reaction mixtures. What is flash chromatography?
How To Test For Contamination In Large Volume Water
Automated Solid Phase Extraction (SPE) of EPA Method 1694 for Pharmaceuticals and Personal Care Products in Large Volume Water Samples Keywords Application Note ENV0212 This collaboration study was performed
Analysis of Drugs by using the Ultra Inert Inlet Liners with Wool
nalysis of Drugs by using the Ultra Inert Inlet Liners with Wool pplication Note Forensic Toxicology uthors Limian Zhao, ruce Quimby gilent Technologies, Inc. 280 Centerville Road Wilmington, DE 19808
Paper Chromatography: Separation and Identification of Five Metal Cations
Paper Chromatography: Separation and Identification of Five Metal Cations Objectives Known and unknown solutions of the metal ions Ag +, Fe 3+, Co 2+, Cu 2+ and Hg 2+ will be analyzed using paper chromatography.
GC/MS BATCH NUMBER: CK0102
GC/MS BATCH NUMBER: CK0102 ESSENTIAL OIL: CORIANDER BOTANICAL NAME: CORIANDRUM SATIVUM ORIGIN: RUSSIA KEY CONSTITUENTS PRESENT IN THIS BATCH OF CORIANDER OIL % LINALOOL 68.8 -PINENE 6.7 CAMPHOR 5.1 -TERPINENE
Mass Spectrometry. Fundamental GC-MS. GC Considerations
Mass Spectrometry Fundamental GC-MS GC Considerations i Wherever you see this symbol, it is important to access the on-line course as there is interactive material that cannot be fully shown in this reference
Guide to Reverse Phase SpinColumns Chromatography for Sample Prep
Guide to Reverse Phase SpinColumns Chromatography for Sample Prep www.harvardapparatus.com Contents Introduction...2-3 Modes of Separation...4-6 Spin Column Efficiency...7-8 Fast Protein Analysis...9 Specifications...10
Determination of Polycyclic Aromatic Hydrocarbons (PAH) in Food with GC-MS/MS
Determination of Polycyclic Aromatic Hydrocarbons (PAH) in Food with GC-MS/MS Thorsten Bernsmann, Peter Fürst Chemical and Veterinary Analytical Institute Münsterland-Emscher-Lippe Joseph-König-Str. 40,
TABLE OF CONTENTS CHAPTER TITLE PAGE DECLARATION ACKNOWLEDGEMENT ABSTRACT LIST OF TABLES LIST OF FIGURES LIST OF SYMBOLS LIST OF APPENDICES
vii TABLE OF CONTENTS CHAPTER TITLE PAGE DECLARATION ii ACKNOWLEDGEMENT iv ABSTRACT v TABLE OF CONTENTS vii LIST OF TABLES xii LIST OF FIGURES xiv LIST OF SYMBOLS xvii LIST OF APPENDICES xviii 1 INTRODUCTION
Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide
chromatography Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide The following guide provides considerations, tips and general guidelines for developing SPE methods using the Thermo
TCI Chiral HPLC Column
TCI Chiral HPLC Column ~ Spiral Polymer New Chiral Stationary Phase ~ Tokyo Chemical Industry Co.,Ltd. Chromatography Department 29 Tokyo Chemical Industry Co., Ltd. Features of TCI Chiral A unique new
AMD Analysis & Technology AG
AMD Analysis & Technology AG Application Note 120419 Author: Karl-Heinz Maurer APCI-MS Trace Analysis of volatile organic compounds in ambient air A) Introduction Trace analysis of volatile organic compounds
Safe Method of Use 7 HSNO Class 3.1 - Flammable Liquids
Safe Method of Use 7 HSNO Class 3.1 - Flammable Liquids A. Classification HSNO Class 3.1 flammable liquids are categorised according to their flashpoints: HSNO Category 3.1A Flammable Liquids with a flashpoint
EKSIGENT EKSPERT NANOLC 400. Unmatched flexibility for low flow LC/MS
EKSIGENT EKSPERT NANOLC 4 Unmatched flexibility for low flow LC/MS EKSIGENT EKSPERT NANOLC 4 Focused ekspertise In 23, Eksigent changed the way scientists looked at nanoscale chromatography with the introduction
Micro Cryo-Trap Model 971
Micro Cryo-Trap Model 971 for Liquid CO2 Cooling Scientific Instrument Services, Inc. 1027 Old York Road Ringoes, NJ 08551 Phone (908) 788-5550 Part #951001M revised 10/ /98 Notice The information in this
This study was performed by Patrick Sullivan and staff at TestAmerica Analytical Testing Corp., Westfield, MA, USA
An Automated Method for the Fractionation of Extractable Petroleum Hydrocarbons (EPH) from Water and Soil Extracts Using the Gilson GX-274 ASPEC System Keywords: Aliphatic Hydrocarbons, Aromatic Hydrocarbons,
Request for Quotes Goods/Trade Services RFQ for Gas Chromatograph Mass Spectrometer (GCMS) (PCS# 600000-1621-RFQ)
Request for Quotes Goods/Trade Services RFQ for Gas Chromatograph Mass Spectrometer (GCMS) Closing Date and Time: Wednesday, April 13, 2016 at 5:00 p.m. (Pacific Time) Contact: Aaron Galloway Fax: 541-888-3250
SCION SQ Series GC-MS
SCION SQ Series GC-MS The Gas Chromatographers Detector SCION SQ TM GC-MS The SCION SQ series GC-MS systems combine innovative engineering with detailed cutomer requirements to produce a truly innovative
Diffusion and Fluid Flow
Diffusion and Fluid Flow What determines the diffusion coefficient? What determines fluid flow? 1. Diffusion: Diffusion refers to the transport of substance against a concentration gradient. ΔS>0 Mass
The Use of Hydrogen Carrier Gas for GC/MS
Technical Note The Use of Hydrogen Carrier Gas for GC/MS Gas Chromatography/ Mass Spectrometry Highlights Guidelines that can mitigate dangers and leverage benefits of using hydrogen Key safety factors
How To Analyze Pesticide Levels In Lemon Oil
AppNote 9/2006 Target GC-MS Analysis using Accelerated Column Heating and Interactive Deconvolution Software Albert Robbat Tufts University, Chemistry Department, Medford, MA 02155, USA Andreas Hoffmann
INSTRUCTIONS 56-1190-98. Edition AC
Sephacryl S-100 High Resolution Sephacryl S-200 High Resolution Sephacryl S-300 High Resolution Sephacryl S-400 High Resolution Sephacryl S-500 High Resolution INSTRUCTIONS Sephacryl High Resolution chromatography
Agilent 7697A Headspace Sampler Data Sheet
Agilent 7697A Headspace Sampler Data Sheet Overview The Agilent 7697A Headspace Sampler is part of Agilent s line of gas chromtography products. The 7697A based on the architecture of the market-leading
Alcohols An alcohol contains a hydroxyl group ( OH) attached to a carbon chain. A phenol contains a hydroxyl group ( OH) attached to a benzene ring.
Chapter : rganic Compounds with xygen Alcohols, Ethers Alcohols An alcohol contains a hydroxyl group ( H) attached to a carbon chain. A phenol contains a hydroxyl group ( H) attached to a benzene ring.
WHITE PAPER CONTINUOUS AIR MONITORING USING GRIFFIN 460 MOBILE GC/MS. HEADINGS: ALL CAPS, 12 PT TREBUCHET FONT, ICx BLUE
WHITE PAPER CONTINUOUS AIR MONITORING USING GRIFFIN 460 MOBILE GC/MS HEADINGS: ALL CAPS, 12 PT TREBUCHET FONT, ICx BLUE Body text is 11 pt Cynthia Georgia Liu, with 1.5 Ph.D., line spacing. Paul Dreier
Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis
Thermo Scientific SOLAµ SPE Plates Technical Guide Consistent excellence for bioanalysis SOLAµ - delivering reproducible low volume extractions. Everytime! Thermo Scientific SOLAµ plates are designed for
MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question.
Ch14_PT MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question. 1) Compounds with the -OH group attached to a saturated alkane-like carbon are known as A)
AC DHA Solutions. Detailed Hydrocarbon Analysis of Light Petroleum Streams & Light End in Crude Oils. ASTM D 5134, D 6729, D 6730, D 6733 Compliance
AC DHA Solutions Detailed Hydrocarbon Analysis of Light Petroleum Streams & Light End in Crude Oils ASTM D 5134, D 6729, D 6730, D 6733 Compliance Signal Alignment Automated with LineUp TM Tool Compatible
Gas Chromatography. Gas Chromatograph
Gas Chromatography Gas Chromatograph Chromatography: Separate analytes in a mixture with a resolution 1.5 in the shortest amount of time and detection of separated components. 1 = m.p. 6 2 4 5 3 Gas supplies
Clarus 580 Gas Chromatograph
S P E C I F I C A T I O N S Gas Chromatography Clarus 580 Gas Chromatograph The PerkinElmer Clarus 580 Gas Chromatograph (GC) is a fully automated gas chromatograph. The system offers the capabilities
ß-CYCLODEXTRIN SYNONYMS
ß-CYCLODEXTRIN Prepared at the 44th JECFA (1995), published in FNP 52 Add 3 (1995) superseding specifications prepared at the 41st JECFA (1993), published in FNP 52 Add 2 (1993). Metals and arsenic specifications
Thermal Conductivity Detector
Thermal Conductivity Detector Troubleshooting Tips The thermal conductivity detector (TCD) detects the difference in thermal conductivity between column effluent flow (carrier gas + sample components)
Simplifi ed assay of diethylene glycol and ethylene glycol in various raw materials by capillary gas chromatography
J. Cosmet. Sci., 61, 225 234 (May/June 2010) Simplifi ed assay of diethylene glycol and ethylene glycol in various raw materials by capillary gas chromatography K. MOLEVER, Research and Development Department,
Ferda ORHUN Mineral Research and Exploration Institute of Turkey
GAS CHROMATOGRAPHY, EXPERIMENTAL STUDIES ON THE FLOW RATE EFFECTS OF CARRIER GAS AND APPLICATION OF THE METHOD TO HYDROCARBON ANALYSIS OF SOME NATURAL GASES IN TURKEY Ferda ORHUN Mineral Research and Exploration
Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE
Waters Corporation Waters 2690/5 USER & TROUBLESHOOTING GUIDE Contents 2690/5 Theory Setup procedures. Troubleshooting the 2690/5 User maintenance of the 2690/5 Spare Parts 2 2690/5 Theory 2690/5 Solvent
LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006)
October 2006 RESTRICTED LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006) DRAFT FOR DISCUSSION World Health Organization 2006 All rights reserved. This draft is intended for
Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction
Advantages of Using Triple Quadrupole over Single Quadrupole Mass Spectrometry to Quantify and Identify the Presence of Pesticides in Water and Soil Samples André Schreiber AB SCIEX Concord, Ontario (Canada)
GCxGC COUPLED TO FAST SCANNING QUADRUPOLE MS FOR TRACE ANALYSIS OF POPs
GCxGC COUPLED TO FAST SCANNING QUADRUPOLE MS FOR TRACE ANALYSIS OF POPs Kinet C, De Pauw E, Focant JF CART, Mass Spectrometry Laboratory, Chemistry Department, University of Liège, Allée de la Chimie 3,
EnAlgae SOP: Biogas analysis
Table of content 1. PURPOSE... 2 2. PRINCIPLE... 2 3. REQUIREMENTS... 3 3.1. EQUIPMENT AND MATERIALS... 3 3.2. REAGENTS... 3 3.3. PREPARATION OF MEASUREMENT... 3 4. PROCEDURE... 4 4.1. SAMPLE MEASUREMENT...
Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection
Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection Application Note 1097 Liu Qian, Zheng Hongguo and
CRYOCOOLER CONTAMINATION STUDY. S.W.K. Yuan, D.T.Kuo, and A.S. Loc. BEI Technologies, Cryocooler Group Sylmar, CA 91342 ABSTRACT
CRYOCOOLER CONTAMINATION STUDY S.W.K. Yuan, D.T.Kuo, and A.S. Loc EI Technologies, Cryocooler Group Sylmar, CA 91342 ASTRACT Eliminating or reduction of contamination is essential for the success of cryocoolers
A Comparison between EPA Compendium Method TO- 15 and EPA Method 8260B for VOC Determination in Soil Gas
A Comparison between EPA Compendium Method TO- 15 and EPA Method 8260B for VOC Determination in Soil Gas Paper #46 Heidi C. Hayes Air Toxics, Ltd., 180 Blue Ravine Rd. Ste. B, Folsom, CA 95630 Diane J.
SSENTIALS RESTEK. A new species of column. Restek Certified. SPP speed. USLC resolution. Restek s EZGC Online Suite. Reference Materials
Now in 2.7 and 5 µm particles! Speed Up and mplify GC Method Development With Restek s EZGC nline Suite SSENTIALS RESTEK Must-Have Solutions for Your Lab 2014.4 SPP speed. USLC resolution. A new species
GC-2010 Gas Chromatograph INSTRUCTION MANUAL
221-40407F Gas Chromatograph INSTRUCTION MANUAL Read this instruction manual thoroughly before using this instrument. Save the manual for future reference. Copyright Shimadzu Corporation 2000. All rights
Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database
C146-E175A Technical Report Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database Hitoshi Tsuchihashi 1 Abstract: A sample consisting
Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan
Fast, Reproducible LC-MS/MS Analysis of and Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 685 Key Words Accucore C18, dextromethorphan, dextrorphan, SOLA CX Abstract