Access control and traffic bollards. Access control and traffic bollards
|
|
|
- Bertram Kennedy
- 9 years ago
- Views:
Transcription
1 Access control and traffic bollards Access control and traffic bollards 165
2 Mag100 Magnetic readers The MAG100 magnetic card reader can be used to realize both pedestrian and vehicle access control systems. Mag100 Swipe magnetic card reader Electronic control board VIPER 400 / COBRA MAG aluminium column Foundation plate for columns Cards FAAC Controls magnetic card, numbered and coded (minimum q.ty 10 pcs.) Technical specifications Enclosure mag100 In metal Power supply voltage 12 Vdc (from the control board) Type of magnetic reader Swipe Format ISO STANDARD track 2 Reading of magnetic strip 100% of track Electrical connections Multipolar cable 5 x 0.5 mm Max. distance between reader and control unit 100 metres - 10 C to + 55 C Installation Wall-mounted or column-mounted Heater Not present LED indications Dual colour multifunction LED Buzzer Can be turned off Dimensions 125 x 56 x 45 mm (L x H x D) Use Vehicle or pedestrian access control systems, indoors and outdoors. 166
3 Tag10 Proximity readers The TAG 10 passive transponder proximity reader can be used to build high-security access control systems. With its distance detection, it offers greater ease of use and, since it is completely free from moving mechanical parts, it is practically maintenance-free. Access control and traffic bollards Tag 10 Proximity reader for passive transponder Electronic control board VIPER 400 (see page 233) / COBRA (see page 240) Aluminium column Foundation plate for column Cards FAAC Controls proximity card, numbered, no magnetic strip (min. 10 pcs) Keyring transponder (min. 10 pcs) Technical specifications Enclosure Power supply voltage Reading distance Protection class Electrical connections Max. distance between reader and control unit two-colour multifunction LED Buzzer Installation Dimensions tag 10 Plastic 12 Vdc (from the control board) ~10 cm IP 54 Multipolar cable 5x0.5 mm 100 metres -10 C to +55 C YES YES (can be turned off) Wall-mounted or column-mounted 70 x 95 x 44 mm (L x H x D) Use TAG 10 Vehicle or pedestrian access control systems, indoors and outdoors. 167
4 Resist Readers for pedestrian and vehicle gates The Resist line of readers for pedestrian and vehicle gates has a very robust anti-vandal structure with a front panel in fibre glass. Resist-T Resist-PS Resist-TPS Resist-T Resist-PS Resist-TPS Keypad for access authorisation by entering a code Passive proximity reader Passive proximity reader with keypad for access authorisation by entering a code Electronic control board VIPER 400 / COBRA Resist-COL Column in galvanised steel, painted black Cards FAAC Controls proximity card, numbered, no magnetic strip (min. 10 pcs) Keyring transponder (min. 10 pcs) Technical specifications Resist-T Resist-PS Resist-TPS Type of reader Keypad, 12 buttons Passive proximity Proximity and keypad Reading distance -- Max. 5 cm Max. 5 cm TAG reading (125 Khz) -- TAG Card / Keyring TAG Card / Keyring Structure die-cast aluminium Dimensions (mm) H100xL100xD42 Front panel Fibre glass with polycarbonate layer Protection class IP 55 Buttons Mechanical buttons in stainless steel no button Mechanical buttons in stainless steel Indication LEd dual-colour, 3 mm Buzzer Can be turned off Power supply From the control board Absorption Max. 60 ma Max. 100 ma Max. 160 ma -10 C to +55 C Installation Wall-mounted or column-mounted Electrical connections 5 x 0.5 mm cable, with screen (max. 100 m) TECHNICAL SPECIFICATIONS RESIST- COL Structure - galvanised steel Painting - black powder Dimensions x100x100 mm Use: vehicle or pedestrian access control systems, indoors and outdoors 168
5 Accessories Interface for radio control 433 SLH DECODER TTR The DECODER TTR interface can be used to realize access control systems with the FAAC 433 SLH / 868 SLH radio control. This system is perfect for vehicle systems, because the driver can control the access opening remotely while remaining comfortably seated in the car. Access control and traffic bollards Decoder TTR Plus / Plus XT4 433 SLH XT4 868 SLH Decoder TTR Interface for programmable transmitters 433 SLH / 868 SLH Technical specifications Plus 1 XT2 XT4 Version 433 SLH 868 SLH 433 SLH 868 SLH 433 SLH 868 SLH Frequency of use SLH MHz SLH MHz SLH MHz Power supply voltage Reading distance Protection class 20 to 30 Vdc 24 Vac ± 10% / IP 44 Battery 12 V ~50 m / Transmission channels / 2 4 Codes available / -20 C to +55 C 72 million billion -10 C to +55 C Compatibility with VIPER 400 / COBRA 5000 board PLUS SLH PLUS SLH XT2 433 SLH XT4 433 SLH XT2 868 SLH XT4 868 SLH Multi-channel receiver Multi-channel receiver 2-channel transmitter 4-channel transmitter 2-channel transmitter 4-channel transmitter Use: vehicle or pedestrian access control systems, indoors and outdoors. Electronic control board VIPER 400. Mixer board Mixer board Interface for combining two readers of different technologies Characteristics The MIXER board allows you to combine two readers on the same input, even if they use different technologies, on the VIPER 400 / COBRA board. This allows pedestrian or vehicle access control systems with a double reader on entry and a double reader on exit (e.g. magnetic and DECODER TTR or magnetic and transponder, etc.) managed by the control board. The MIXER board is supplied with a mounting for a DIN bar and is therefore compatible with enclosure models E - L - LM. 169
6 Minitime New Readers for pedestrian and vehicle gates The range of MINITIME keypads and readers is ideal for access control systems both for pedestrians, indoors in prestige locations, and for vehicles outdoors. Minitime-T Minitime-PS Minitime-TPS Keypad for access authorisation by entering a code Passive proximity reader Passive proximity reader with keypad for access authorisation by entering a code Electronic control board VIPER 400 / COBRA. MINITIME aluminium column Foundation plate for columns Cards FAAC Controls proximity card, numbered, no magnetic strip (min. 10 pcs) Keyring transponder (min. 10 pcs) To obtain personalised cards contact the FAAC S.p.A. export department Technical specifications Minitime - T Minitime - TPS Minitime - PS Keypad, 12 buttons yes yes no Type of reader no Passive proximity TAG reading distance no Max. 5 cm TAG format no Card / keyring at 125 KHz Operating principle connected with VIPER 400 or COBRA 5000 Signalling dual colour multifunction led Front panel Stainless steel with polycarbonate layer Buzzer Incorporated Installation Wall-mounted or column-mounted Connections to control unit Multipolar cable 5 x 0.5 mm, screened Distance from reader to control unit 100 MT Type of enclosure ABS with painted cover, dimensions H 175 L 60 D 45 mm -10 C to +55 C Power supply directly from the control board COBRA 5000 and VIPER 400 Use: vehicle or pedestrian access control systems, indoors and outdoors. 170
7 Viper 400 Control board VIPER 400 The autonomous VIPER 400 control board is designed for stand-alone access control systems (it does not require a personal computer). It is ideal for all situations requiring a simple but secure system. Access control and traffic bollards Viper 400 Enclosure for VIPER 400 electronic board Enclosure mod. E Enclosure mod. L Enclosure mod. LM Power supply for VIPER 400 board MINISERVICE power supply (necessary for managing electric locks at 12 Vac (*) Accessories for installing MINISERVICE in enclosures L - LM Memory for saving data held in the VIPER 400 board Technical specifications VIPER 400 Up to 2 readers can be connected - MAG, TAG transponder, or RESIST - or 433/868 SLH trasmitters using the DECODER TTR Memory capacity up to 400 users Programmable control of a single gate or two gates: single gate: entry reader/button to exit; entry reader/exit reader; possibility of door status management with alarm activation two gates: reader on entry A; reader on entry B (on gate A an exit button can be installed and also a door status management with alarm activation) Can add access password to configuration and programming 1 3-digit display for programming and displaying card status 5 programming buttons Programs available: Card management (saving, deleting, changing) Operational settings (manage one gate, manage two gates etc.) Time settings Activation of exits Export/import archives The additional memory, optionally available, can be used to export/ import the "card data" from one board to another, or to make backup copies Power supply 12 to 24 Vac/Vdc Compatible with enclosure models E - L - LM. Notes (*) When the Miniservice power supply is used to activate an electric lock (12 V ac) the power for the VIPER board can be taken from the Miniservice (24 V dc). In this case the VIPER 400 power supply is not required. Obviously not all electric locks are compatible with the Miniservice. 171
8 TAG10 SA stand-alone proximity reader The TAG-10-SA is an access control device that can archive access cards and command the opening of a door, control the status (open/closed) and sound an alarm in the event of unauthorised opening. It works totally autonomously ("SA" means Stand Alone) with no external management board or computer for programming and downloading data. The electronic control unit comprises two interconnected boards: - The CPU board, which contains the terminals, buzzer, relays and interface for the passive reader - The keypad board with the buttons, the LED indicators and the antenna for passive proximity reading. The TAG-10-SA (reader A, master) can connect with a standard TAG-10, currently available (reader B, slave). This configuration can manage an area with two entry/exit gates, controllable with Anti-Pass-Back. Configuring the reader and acquiring the cards is done using the cards programming kit. The additional memory, optionally available, can be used to export/import the card list from one TAG-10-SA to a similar product. TAG10 SA Stand-alone proximity reader SA CARDS KIT - Programming cards Aluminium column Foundation plate for column Memory for saving data Cards FAAC Controls proximity card, numbered, no magnetic strip (min. 10 pcs) Keyring transponder (min. 10 pcs) Technical specifications Type of device Control board Reading distance TAGs handled External structure Dimensions (mm) Front panel Protection class LED indications Buzzer Input Output Number of users Control of one door Control of two doors Door A Door B Configuration Power supply Absorption Fixing Master-slave connection cable TAG10 SA Proximity reader Integrated Max. 10 cm Cards/Keyrings Plastic H95 x L70 x D44 Plastic IP 54 a) Programming - b) Reading OK Card recognised, error status 1 door status input - door opening input (button) - 2 relay outputs - 1 open collector output (alarm) 500 cards 1 TAG-10-SA - master - 1 TAG-10 - slave 1 TAG-10-SA (A) - master 1 TAG-10 (B) - slave 1 door alarm (A) - 1 door input (A) Cards kit 12/24 Vdc - 12/21 Vac Max. 180 ma -10 C to +55 C Wall-mounted or column-mounted 5 x 0.5 mm, screened (max. 100 m) 172
9 Resist SA Stand-alone readers / keypads RESIST-SA is an access control device that can archive codes or cards and command the opening of a door, control the status (open/closed) and sound an alarm in the event of unauthorised opening. It works totally autonomously ("SA" means Stand Alone) with no external management board or computer for programming and downloading data. The electronic control unit comprises two interconnected boards: - The CPU board, which contains the terminals, buzzer, relays and interface for the passive reader - The keypad board with the buttons, the LED indicators and the antenna for the passive proximity reader. RESIST-SA (reader A, master) can connect with a standard RESIST, currently available (reader B, slave). This configuration can manage an area with two gates, one entry and one exit, controllable with Anti-Pass-Back. Configuring the reader and acquiring the codes or cards can be done via the keypad or using the kit for card programming. The additional memory, optionally available, can be used to export/ import the list of cards or codes from a Resist-SA to a similar product. Resist PS SA Resist T SA Resist TPS SA Access control and traffic bollards Resist PS SA Resist T SA Resist TPS SA Stand-alone proximity reader Stand-alone keypad Reader + stand-alone SA CARDS KIT - Programming cards Resist-COL column in galvanised steel, painted black Memory for saving data Cards FAAC Controls proximity card, numbered, no magnetic strip (min. 10 pcs) Keyring transponder (min. 10 pcs) Technical specifications Resist-T-SA Resist-PS-SA Resist-TPS Type of device Keypad Proximity reader Keypad with proximity reader Control board Integrated Reading distance - Max. 5 cm Max. 5 cm TAGs handled - Cards/Keyrings Cards/Keyrings External structure Die-cast aluminium Dimensions (mm) H100 x L100 x D42 Front panel Fibre glass with polycarbonate layer Protection class IP 55 Type of keypad (12 buttons in steel) (0-9), Enter, Space - (0-9), Enter, Space LED indications a) Programming - b) Reading OK Buzzer Code recognised, Card recognised, error status Card/code recognised, error status error status Input 1 door status input - door opening input (button) Output 2 relay outputs - 1 open collector output (alarm) 500 codes or cards Number of users 500 PIN codes 500 cards 1 Resist-TPS-SA -1 Resist-TPS Control of one door 1 Resist-T-SA -1 Resist-T 1 Resist-PS-SA - 1 Resist-PS 1 Resist-TPS-SA (A) Control of two doors 1 Resist-T-SA (A) 1 Resist-PS-SA (A) 1 Resist-TPS-SA (A) Reader A 1 Resist-T (B) 1 Resist-PS (B) 1 Resist-TPS (B) Reader B 1 door alarm (A)- 1 door input (A) 1 door alarm (A) - 1 door input (A) 1 door alarm (A) - 1 door input (A) Configuration Keypad Cards kit Keypad, cards kit Power supply 12/24 Vdc - 12/21 Vac Absorption Max. 180 ma -10 C to +55 C Fixing Wall-mounted or column-mounted Master-slave connection cable 5 x 0.5 mm, screened (max. 100 m) 173
10 Minitime SA New Stand-alone readers / keypads MINITIME-SA is an access control device that can archive cards and command the opening of a door, control the status (open/closed) and sound an alarm in the event of unauthorised opening. It works totally autonomously ("SA" means Stand Alone) with no external management board or computer for programming and downloading data. The electronic control unit comprises two interconnected boards: - The CPU board, which contains the terminals, buzzer, relays and interface for the passive reader - The keypad board with the buttons, the LED indicators and the antenna for passive proximity reading. MINITIME-SA (reader A, master) can connect with a standard MINITIME currently available (reader B, slave). This configuration can manage an area with two gates, one entry and one exit, controllable with Anti-Pass-Back. Configuring the reader and acquiring the Codes or Cards can be done via the keypad or using the kit for card programming. The additional memory, optionally available, can be used to export/import the list of cards or codes from a MINITIME-SA to a similar product. Minitime PS SA Minitime T SA Minitime TPS SA Stand-alone proximity reader Stand-alone keypad Reader + stand-alone SA CARDS KIT - Programming cards Minitime aluminium column Foundation plate for column Memory for saving data Cards FAAC Controls proximity card, numbered, no magnetic strip (min. 10 pcs) Keyring transponder (min. 10 pcs) Technical specifications Minitime-T-SA Minitime-TPS-SA Minitime-PS-SA Keypad, 12 buttons yes yes no Type of reader no Passive proximity TAG reading distance no Max. 5 cm Operating principle stand-alone Programming Via keypad and 3 LEDs Via cards Special functions Saving and deleting of cards, operational settings and exit activation times anti-passback management Import/export card archive on additional memory Connection of external readers Inputs Outputs Inputs Outputs Number of users 500 More codes 1 standard reader without keypad or display 2 inputs for button and door status 2 relay outputs for door-opening, 1 open-collector output for alarm 1 door status input 1 door opening input (push-button) 2 relay outputs 1 open collector output (alarm) 500 cards 500 codes or cards Single gate management Double gate management Type of enclosure Power supply entry reader / exit button, entry reader / exit reader, door management with alarm activation entry reader, exit reader alarm activation ABS with painted cover, dimensions H175 L60 D45 mm C Vdc Vac, max. absorption 200 MA 174
11 Time TIME pedestrian access control readers The TIME range of readers with keypad and display are especially suitable for pedestrian access control and for detecting presence. With their enclosure in ABS, they're ideal for outdoor installations as well. The readers must be connected to a COBRA control unit. Access control and traffic bollards Time M Time T Time M Time T Magnetic reader with keypad and display Passive proximity reader with keypad and display Electronic control board: Cobra management unit. Use: high-security pedestrian access control systems, indoors and outdoors. Technical specifications Time m time t Type of reader Standard ISO-2 magnetic swipe reader Passive proximity reader Type of cards used Reading distance Reading of magnetic strip Keypad Display Installation of reader Enclosure COBRA installation Electrical connections Power supply Dimensions ISO-2 magnetic cards Proximity cards and TAG keyrings at 125 khz on contact Max. 10 cm 100% of track - Standard 12 keys, 0-9 E C, 5 function keys, 4 scroll keys, OK 16x2 characters, backlit Wall-mounted In ABS External to reader, at max. distance of 40 m Multipolar cable 9 x 0.5 mm 2, screened From the Cobra control unit -10 C to +55 C H 170 x L110 x D70 mm Applications/Functions - the keypad can be used to enter: Codes associated with the card used (double security) system activation code justification codes activation / deactivation codes for other systems (e.g. alarm system etc.) The information display shows: Calendar with date and time Messages about the tickets/cards used (card valid, card invalid, outside permitted times, etc.) Messages about the codes entered Information messages sent by a central computer SPECIAL VERSIONS Time M T Magnetic and passive proximity reader with keypad and display
12 A100 Cards compact Passive cards and transponders Magnetic cards and proximity cards in STANDARD ISO format (credit card size, 86x54x0.78 mm) are available. Proximity cards are also available in a convenient keyring format. For all types of card, the minimum order is 10 pieces, except for personalised cards (see note at end of page). Magnetic card, FAAC Controls, numbered and coded Proximity card, white, no magnetic strip Proximity card, white, numbered, no magnetic strip Proximity card, FAAC Controls, numbered, no magnetic strip Proximity card, white, numbered, with neutral magnetic strip Proximity card, white, numbered, with coded magnetic strip Transponder keyring format
13 AT 8 Vehicle access control unit with detection at a distance and at speed AT-8 The AT-8 control unit is designed to identify vehicles equipped with TAGs active at 2.45 GHz, installable on the windscreen of the vehicle using sucker cups. Double identification is possible (for vehicle and driver), with the PROX-BOOSTER active transponder. AT-8 Prox-Booster Compact TAG Window button Access control and traffic bollards AT - 8 Reader unit for long-range active transponders at 2.45 GHz Electronic control board Control unit COBRA LONG-RANGE active transponders at 2.45 GHz COMPACT TAG WINDOW BUTTON PROX-BOOSTER - (active TAG ready to receive passive card) Proximity card for PROX-BOOSTER Detector FG1 Detector FG2 Pole for AT-8 Technical specifications Reading unit Detection speed TAG reader Structure Installation Front panel Dimensions Weight Power supply voltage Absorbed current Protection class Interface Identification signal Max. distance between reader and control unit For detection up to 8 m Max. 200 km/h Active at 2.45 GHz In stainless steel on articulated support Wall-mounted or rod-mounted In plastic 310 x 250 x 100 mm 5 kg -20 C to +55 C 230 V~ (+6% -10%) 50 (60) Hz 125 ma IP 65 RS232 or OMROM ISO 7811/2 Buzzer 50 m Technical specifications of transponder Reading distance COMPACT TAG 5 m WINDOW BUTTON 8 m PROX-BOOSTER 8 m Power supply Lithium battery, 5 year life Lithium battery, 5 year life Lithium battery, 5 year life Fixing slot one suction cup three suction cups Dimensions 86 x 59 x 5 mm (L x H x D) Ø 75 mm D 30 mm 116 x 72 x 32 mm (L x H x D) Use: vehicle access control with detection at a distance and at speed. Applications: identification without stopping the vehicle, dynamic control of vehicle access, vehicle fleet management with identification of vehicle and driver (PROX-BOOSTER). 177
14 Cobra Control unit The COBRA control unit, together with the WINCONTROL software, allows the setup of access control systems of any type and size and can handle over 500 readers with WIN-NET network connection. All the technologies for handling access tickets or cards and their readers are managed by the COBRA units. Memory capacity for up to 65,000 users, management of 999 time bands on a weekly basis, management of annual calendar with holidays if there is an online connection with the WINCONTROL software. Cobra 5000 Supplied with stabilised power supply and enclosure LM (IP55) Battery 12 Volt 1.2 Ah Converter ETH Converter ETH-MOD-V Technical specifications Access control system CPU Program memory Tables + transactions memory Serial ports Operating principle Readers management User management (stand-alone) Readings archive management (stand-alone) Time bands management (stand-alone) Parking lanes management Single door management Double door management PIN management Inputs and outputs Power supply voltage Pedestrian and vehicle 16/32 bit 512 Kbyte flash memory, updatable via serial port, containing all functional variants 512 Kbyte buffered RAM 1 RS 232 serial port - 1 auxiliary RS 232 serial port - 1 RS 485 serial port 1 RS 485 serial port for subnet management In stand-alone mode if configured from a laptop PC, or on a network with a PC Max. 2 readers (4 with MIXER board) Variable from 10 to 15,000 - Preset to 5,000 Variable from 200 (15,000 cards) to 51,000 (10 cards) - Preset to 34,189 with 5,000 users or 2, programmable entry reader, exit button; entry reader, exit reader possibility of door status management with alarm activation reader on gate A; reader on gate B on both, exit buttons can be installed and also door status management and alarms Via connection with a reader equipped with display + keypad (PIN and PIN+card) 6 inputs, 1 anti-intrusion tamper, 4 relay outputs 230 V (+ 6% to 10%) 230 Vac 178
15 Software Management software The WINCONTROL access control software allows management of terminals or control units connected to the data concentrator computer. The software manages a series of archives of user information, identification criteria for personnel subject to checking, operation modes, both for the control units and for the readers installed at the gates, and accesses of controlled areas. All versions handle up to 65,535 users and include the modules: - 8 ore (8 hours), for counting and processing the times read - WINCONTROL-PRES, for exporting data to other computer systems - WINCONTROL-NET, for monitoring and sharing of the archives of a WINCONTROL installed on another PC on a LAN. Access control and traffic bollards Accessories for PC Interface converter INT ISO (4 lines) Analogue modem for access control Software for management, Wincontrol 1P (for 1 COBRA) connectable directly to the serial port (RS 232) of the PC (*) for management, Wincontrol 5P (for 5 COBRAs) operating on a WinNet network via converter to four lines for management, Wincontrol 10P (for 10 COBRAs) operating on a WinNet network via converter to four lines for management, Wincontrol 255P (for 255 COBRAs) operating on a WinNet network via converter to four lines Technical specifications Operating system Access Communication Identification User associations Logistics controls Time controls Conditioning of opening Microsoft Windows (95/98/NT/2000/XP/VISTA) Confidential password Serial port Transponder card, magnetic card, PIN code Unlimited level of accesses Enabled zones, movements, anti-pass back, entering amounts 999 time bands/week Level of accesses, time bands, PIN codes, temporary disablings 179
MAG/MAG100 magnetic reader. TAG-10/TAG-5/TAG-3 proximity readers
Access control MAGMAG100 magnetic reader The MAGMAG100 insertion magnetic card reader, makes it possible to create access control systems for both vehicles and pedestrians. MAG MAG 100 MAG MAG 100 Enclosure
ACCESS CONTROL SYSTEM
ACCESS CONTROL SYSTEM Flexible, Expandable, Economical. The i-pass system comprises of the i-pass controller built with state of the art technology to provide reader access for up to 16 doors and 32 elevator
VIPER 400 ENGLISH ENGLISH
VIPER 400 These instructions apply to the following model: VIPER 400 electronic appliance 1.2. LAY-OUT OF VIPER CARD CE DECLARATION OF CONFORMITY DIS Manufacturer: FAAC S.p.A. J8 Address: Via Benini, 1-40069
contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control
Wireless Control Systems Accessories Leading the way in intelligent automation contents Range Overview Typical Installations Transmitters Combined Modules Accessories Programming Switching & Dimmer Functions
FIREDEX 2200. Conventional Fire Panels
68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class
ACCESS CONTROL SECURITY SYSTEMS TRANSMITTERS SHOW-WINDOWS PROTECTION COMPONENTS FOR GATES AUTOMATION
ACCESS CONTROL SECURITY SYSTEMS TRANSMITTERS SHOW-WINDOWS PROTECTION COMPONENTS FOR GATES AUTOMATION 2014 Ferport/Armas has over 30 years been synonymous with technology, reliability and experience in
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
Always on the Lookout Perfect Protection against Burglary
Always on the Lookout Perfect Protection against Burglary Terxon wired and hybrid alarm systems One system offers all possibilities Rely on experts With a qualified specialist installation contractor on
www.smarcom.biz BARCODE TICKET SOLUTION RF CARD SOLUTION MAGNETIC TICKET SOLUTION
BARCODE TICKET SOLUTION RF CARD SOLUTION MAGNETIC TICKET SOLUTION C A R PA R K M A N A G E M E N T S Y S T E M C A R Barcode ticket application PA R K M A N A G E M E N T S Y S T E M RF card application
EQUIPMENT SPECIFICATIONS
EQUIPMENT SPECIFICATIONS IC-1600 Intelligent Controller The IC-1600 Intelligent Controller is a fully intelligent panel that has a complete database on board. It operates in conjunction with the Access
Ticket Reader with real time clock and magnetic encoding
Ticket Reader with real time clock and magnetic encoding Order number: TL-31 The Ticket Reader TL 31 consists of the multifunctional MODPARK ticket modules integrated into a housing, which is well suited
AC-115 Compact Networked Single Door Controller. Installation and User Manual
AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.
INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.
SA-2000-II HARDWARE MANUAL Access Technologies International, Inc. 1 Table of Contents 1. Introduction 3 2. Features 3 3. Specification 4 4. Identifying Supplied Parts 4 5. Panel Description 5 6. Connection
EASY PROGRAMMING AND TRANSACTION ANALYSIS SOFTWARE
EASY PROGRAMMING AND TRANSACTION ANALYSIS SOFTWARE You can program online 24/7 giving you the freedom to work when and where you want. From remote bookkeeping and access, to security control on the ground
HyperAccess Access Control System
Control System We manufacture, an advanced PC based access control solution that will give you control over who has access to your building. With you can control access on hundreds of doors for up to 10,000
Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling
Electronics Ltd Presenting Power, Intelligence... with a sense of feeling By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford Plug in slots K772
Temperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
Frequency selective monitoring and logging of environmental electromagnetic fields
FREQUENCY SELECTIVE EMF AREA MONITOR AMS-8060 Frequency selective monitoring and logging of environmental electromagnetic fields Up to 20 fully programmable frequency bands Real built-in spectrum analyser
My2B. MyALARM2 GSM/GPRS Datalogger with Alarm Management
My2B GSM/GPRS Datalogger with Alarm Management 100% Made & Designed in Italy My2B GSM/GPRS Datalogger with Alarm Management MY2B ( Standard / Datalogger) is a GSM / GPRS telecontrol unit for home & building
BIBUS VOP. large blocks of flats with switchboard and mixed mainly audio systems. Ideal for door phone systems with up to 250 users.
BIBUS VOP Advice for use: large blocks of flats with switchboard and mixed mainly audio systems Ideal for door phone systems with up to 250 users VOP technology Easy creation of mixed audio and video door
INSTALLATION MANUAL XM3 Reader
INSTALLATION MANUAL XM3 Reader Conditions Transactions, deliveries et cetera will be according to the general terms of delivery as deposited at the Chamber of Commerce at Meppel, The Netherlands. Registration
Vibration Monitoring System Adash 3600
" User's guide Application: Vibration Monitoring System Adash 3600! Vibration diagnostics, monitoring and protective on-line system! On-line vibration monitoring system of engines, fans, pumps, gearboxes,
Repeaters and Mimics Data Sheet
Repeaters and Mimics Data Sheet IDR series repeaters and mimics allow vital information from a Notifier fire system to be communicated to points around a building remote from the fire alarm control panel.
FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS
FLEET MANAGEMENT & CAR SECURITY SYSTEM FOR PROVIDERS AND CUSTOMERS The Tracker Server Communication Program for data collection The Tracker Client Map Program intended for dispatching desks The GSM/GPRS
A C C E S S C O N T R O L S Y S T E M
A C C E S S C O N T R O L S Y S T E M TIME & ATTENDANCE SYSTEM Model No. Z.AC.R.BIO.M8.TA Z.AC.RC.BIRO.M8+ID.TA Type: BIOMETRIC TIME & ATTENDANCE SYSTEM Combination of silver & black colour Instant verification
SECTION 13850 DETECTION AND ALARM
SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
ABLOY DOOR AUTOMATICS Easy access for all types of swing doors
ABLOY DOOR AUTOMATICS Easy access for all types of swing doors Automatic door operators bring additional convenience in situations where the doors opening manually would be inconvenient or laborious. Recommended
Alliance System Ordering Guide
Alliance System Ordering Guide Multiple Technologies Versatile Hardware Powerful Software One family of parts and accessories Version 12-Nov-03 Alliance System Ordering Guide Table of Contents Controllers
PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00
Standalone door control module PK-01 Firmware version 1.00 pk-01_en 06/12 SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 [email protected] www.satel.eu WARNINGS Read carefully
NiceBar System. New range of road barrier systems to control accesses in public and private parking areas, even where traffic is heavy.
The NiceBar System New range of road barrier systems to control accesses in public and private parking areas, even where traffic is heavy. L/M/S Bar Barrier gate operators for all sizes New range of barrier
BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS
BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS BURGLAR ALARM SYSTEM EURO ALARM Six zones with the following connection capabilities: One
International Journal of Engineering Research & Management Technology
International Journal of Engineering Research & Management Technology March- 2015 Volume 2, Issue-2 Radio Frequency Identification Security System Mr. Shailendra Kumar Assistant Professor Department of
Security. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000
Security Alarm Central Unit 3 4 Technical KNX Alarm central unit EAM 4000 ETS-product family: Alarm system Product type: Alarm central unit The alarm central unit is a modern alarm system using the KNX
How To Use A Ds340 (Dsp)
Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes. Innovative Dynamic Detection Principle (DDP) measurement technique Immune to gradual reductions
GSM HOME SECURITY SYSTEM
Cell /Mobile phone home security system GSM HOME SECURITY SYSTEM Model : GSM-120 TABLE OF CONTENTS 1. FEATURES... 1 2. APPLICATION... 2 3. SPECIFICATIONS... 3 4. FRONT PANEL & LAYOUT DESCRIPTION...6 5.
Versatility, reliability and expandability are the three main features that make the N-1000 one of the most popular access control panels ever.
Versatility, reliability and expandability are the three main features that make the N-1000 one of the most popular access control panels ever. Expandability is the most important feature of any access
ELITE-L Series. ELITE - Low Voltage / Dry contact Remote Control System
ELITE-L Series ELITE - Low Voltage / Dry contact Remote Control System Applications Garden Lighting Pond pumps Remote outdoor Switching Access control Industrial control Features 4 switched channels 1000W
Gen4 Intruder Alarm Panels SIMPLY SECURE. For Residential & Small Commercial Applications
Gen4 Intruder Alarm Panels SIMPLY SECURE For Residential & Small Commercial Applications Overview and features 8 Zones Each one is separately identified on the keypad and provides ample security detection
1838AP 1810AP PG. 48 PG. 42
Telephone Entry PLUS Computer Programming and Control. The DKS Access Plus product line is a true hybrid access control and telephone entry system that is ideal for residential, small apartment, condominium,
Ex15x //DATASHEET. Xs4 Mini. Cutting-edge design + Amazing technology:
//DATASHEET XS4 Mini Cutting-edge design + Amazing technology: Stylish design is a SALTO trademark and with the XS4 Mini, we raise the bar on this already high standard thanks to the XS4 Mini s small,
CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access
CSP Combined Series Telephone Door Entry with Proximity Keyfob Access PD-094 Issue 3 General Description The CSP series systems are combined Door Entry Telephone and Proximity Access Systems. The entrance
Business/Home GSM Alarm System. Installation and User Manual
Business/Home GSM Alarm System Installation and User Manual Brief Introduction: GSM 900/1800/1900 bands, can be used in most parts of the world Full duplex communication with the host Monitor the scene
Adaptability to Enhanced Security
Installer Guide Adaptability to Enhanced Security AdapTec Plus combines power supply and door access controller features in a compact casing for an encrypted and secure I/O function, enhancing door access
PRT3 Printer Module: ASCII Protocol Programming Instructions
PRT3 Printer Module: ASCII Protocol Programming Instructions We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send
Continuous, remote monitoring and logging of electromagnetic fields
MULTI-BAND EMF AREA MONITOR AMB-8057 Continuous, remote monitoring and logging of electromagnetic fields Discrimination of GSM and UMTS contributions to total emf values Magnetic fields monitoring from
Adaptability to Enhanced Security
Installer Guide Adaptability to Enhanced Security AdapTec Plus combines power supply and door access controller features in a compact casing for an encrypted and secure I/O function, enhancing door access
ELECTRONIC LOCKING SYSTEMS
ELECTRONIC LOCKING SYSTEMS Electronic Locking Systems Electronic locks for display cases, lockers and sliding doors This small intelligent electronic cabinet lock has a wide range of uses. Based on a
Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected
Niagara Security Overview Niagara Security by Tridium, is an open, web-based security management solution that allows you to manage and monitor your facility anytime, anywhere. Built on Tridium s Niagara
AR-721U/721K/661U User s Guide
AR-72U/72K/66U User s Guide Feb. 6, 2004 Table of Contents Page. Main Feature --------------------------------- 3 2. AR-72U Installation --------------------------------- 4 2. Steps ---------------------------------
Hills wireless security alarm DIY range
Hills wireless security alarm DIY range EASY TO INSTALL DIY system PEACE OF MIND Receive SMS/calls when alarm is armed INTERACTIVE Arm and disarm by SMS or via smartphone app Control your alarm via smart
Wireless Alarm system s manual
MOUNTVIEW TECH AUSTRALIA PTY LTD Wireless Alarm system s manual ADS A180 Series ADS Security 1/11/2011 1. Before You Begin For your safety and the safety of others, and to ensure that you get the most
Ensto Chago Master EVM300 and EVM500 Operational description
Pages: 1 (8) Ensto Chago Master EVM300 and EVM500 Operational Pages: 2 (8) Contents 1 What is Ensto EVM... 3 2 EVM versions... 3 2.1 EVM300... 4 2.2 EVM500... 5 3 Technical information... 7 Pages: 3 (8)
HomeSafe-Basic VT-PS99E. User s Manual. PSTN Home Alarm System. Page: 1 / 15
HomeSafe-Basic VT-PS99E User s Manual PSTN Home Alarm System Page: 1 / 15 Table of Contents 1. Product Overview:... 3 2. Main Functions & Features... 3 3. For Your Safety... 4 4. VT-PS99E Characteristics...
Business/Home GSM. Alarm System(III) Installation and Users guide
Business/Home GSM Alarm System(III) Installation and Users guide I. General information: GSM 900/1800/1900 bands, can be used all over the world. Full duplex communication with the base. Monitor environment
MANAGEMENT SOLUTION (P.A.M.S.)
DOORKING SYSTEMS ACCESS CONTROL SOLUTIONS PERIMETER ACCESS MANAGEMENT SOLUTION (P.A.M.S.) Revision N, updated 01.12 PERIMETER ACCESS MANAGEMENT SOLUTION (P.A.M.S.) Design Concept How the System Works TYPICAL
Rev 06 1211. GSM base station. Installation instructions
Rev 06 1211 GSM base station Installation instructions Output string format Baud rate 115200 bps Parity none Data bits 8 Stop bits 1 Flow control none The output string is a modified version of the Sureguard
User Manual. Before installation and use, please read the user manual carefully.
Sebury Technology Co., Ltd. Address: 5/F, Building 8, Xinwu Industrial Park, Xili, Nanshan District, Shenzhen, China. Tel: +86-755-88856 Fax: +86-755-888565 P.C.: 58055 www.sebury.com.cn User Manual Before
Knowledge Base Article. Integrating ISONAS Access Control System with TagMaster LR-series RFID Readers
Knowledge Base Article Integrating ISONAS Access Control System with TagMaster LR-series RFID Readers Copyright 2009-2012, ISONAS Security Systems All rights reserved Table of Contents 1: INTRODUCTION...
GSM ALARM SYSTEM USER MANUAL
GSM ALARM SYSTEM USER MANUAL 1. Instruction The alarm system is based on GSM network. With a GSM SIM card, it can be used wherever you want and no need to connect any wire, which is convenient and easy
Installation manual. Version 1.1. www.videx-security.com
Installation manual Version 1.1 www.videx-security.com 2 Table of Contents MANUAL INTRODUCTION... 4 SYSTEM INTRODUCTION... 4 SYSTEM COMPONENTS... 5 CONTROLS... 6 3.5A 13.8Vdc PSU... 6 CONTROL PCB... 6
OPEN PARK. Automatic Number Plate Recognition that works worldwide including Egypt Number plates
Automatic Number Plate Recognition that works worldwide including Egypt Number plates Free subscription lane, ticket dispenser for nonmembers, ticket readers, e- payment with NFC OPEN PARK INTEGRATED PARKING
INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK
Security Door Controls 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: [email protected] INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP
Business/Home. GSM Alarm system
Business/Home GSM Alarm system Installation and Users guide Profile For a better understanding of this product, please read this user manual thoroughly before using it. I. General information: GSM 900/1800/1900
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE
1.44 kw Programmable DC Power Supplies XLN Series
Data sheet 1.44 kw Programmable DC Power Supplies XLN Series New Family of High Density System Power Supplies The B&K Precision XLN series are compact, programmable, single-output DC power supplies, suitable
SNMP Web Management. User s Manual For SNMP Web Card/Box
SNMP Web Management User s Manual For SNMP Web Card/Box Management Software for Off-Grid Inverter Version: 1.2 Table of Contents 1. Overview... 1 1.1 Introduction... 1 1.2 Features... 1 1.3 Overlook...
CKM-EP2500, CKM-EP1501, and CKM-EP1502 Mercury Network Controllers
Johnson Controls, Inc. now offers Mercury Security Corporation s high-quality access control hardware products, which can be integrated with the Johnson Controls P2000 Security Management System (SMS)
LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER
LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER System for flow measurement, data acquisition and transmission for wastewater with long battery life With Long Life Battery Open Channel Flow Meter
How To Program A Powerline System On A Dgma1D (Dgma) With A Smartcard And A Powercard (Dm1D) On A Pcv123D (Powerline) On An Iphone Or
PCV123D Terminal Unit and DGM1D 1-Door Controller + Contactless Smartcard Reader Version 2.0 G00301FR0219V02 DGM1D: 1-door controller + contactless smartcard reader PCV123D: Terminal unit + PC software
Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS
Vehicle or Personal Position Tracking Vehicle Status and Speed Tracking Auto Accident Report Global Position System (GPS) Navigation System Anti theft Alarm System Overview 1. GPS data tracking via GSM
Page 1 / 14 Groupe MOBILITECHMIOSBOX Technical Specification MWP-DT1010. Technical specifications
Page 1 / 14 Technical specifications Page 2 / 14 SUMMARY 1. GENERAL OVERVIEW 1.1 MIOS and the remote management 1.2 The MIOSBOX range 1.3 Synthesis of MIOSBOX s specificities 2. DETAILED PRESENTATION OF
APR-PRT3 Printer Module: C-Bus Programming Instructions
APR-PRT3 Printer Module: C-Bus Programming Instructions We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send us
FLOOR INDICATORS CATALOGUE 2007
FLOOR CATALOGUE 2007 All Your Needs For Elevators INDEX 1. LCD Indicators... 3 2. Dot Matrix Indicators... 9 3. Accessories... 17 ALBEN İnşaat Makine Elektrik Elektronik San. ve Tic. Ltd. Şti 2/21 LCD
AC3200 INTELLIGENT BROADBAND AMPLIFIER
Kari Mäki 9.4.2013 1(7) AC3200 INTELLIGENT BROADBAND AMPLIFIER AC3200 is the latest leading-edge addition to AC family with extended frequency and gain ranges and integrated electrical controls in both
CAR PLATE CAMERAS & ANPR
CAR PLATE CAMERAS & ANPR Image from a standard D&N Camera Image from the Plateview Plate View Installation Guidelines H D L PVPark Max car speed 15mph (25Km/h) Model PVPark 3-5 PVPark 5-7 PVPark 7-9 Plate
VARIO PROX CARD READER INSTALLATION MANUAL
VARIO PROX CARD READER INSTALLATION MANUAL TABLE OF CONTENTS 1.0 INTRODUCTION...2 1.1 Legend...3 1.2 Terminology...4 2.0 MOUNTING...5 3.0 WIEGAND CONNECTION...6 4.0 AUX BUTTON INPUT...7 5.0 INSTALLER PROGRAMMING...8
Product Specification instalert Rapid Messenger Variable Message Sign
instalert 2 units to cover any application instalert 18 (ia18): 18 x 28 full matrix instalert 24: (ia24): 24 x 60 full matrix Size, Weight without battery ia18: 30 x 20 x 2.74, 29 lbs ia24: Folds to fits
Wireless AUTODIAL GSM SMS Home Alarm Security System 900/ 1800/ 1900Mhz(CK-GSM-9003)
CN2HK LIMITED Wireless AUTODIAL GSM SMS Home Alarm Security System 900/ 1800/ 1900Mhz(CK-GSM-9003) User Manual Please read this manual before operating this product. After you finish reading this manual,
A-307. Mobile Data Terminal. Android OS Platform Datasheet
A-307 Mobile Data Terminal Android OS Platform Datasheet Revision 1.1 July, 2013 Introduction A-307 Platform Overview Introduction A-307 Platform Overview The A-307 provides Original Equipment Manufacturers
ACR120 Technical Specifications version 2.9 November 2005
Version 2.9 11-2005, Email: [email protected] Website: www.acs.com.hk ACR120 Contactless Reader/Writer 1.0 Introduction The ACR120 is a compact and cost-effective contactless reader and writer. It is developed
How To Sell A Talan
The TALAN represents state-of-the-art capability to rapidly and reliably detect and locate illicit tampering and security vulnerabilities on both digital and analog telephone systems. Marketing Characteristics
GV-AS/EV Controller. User s Manual
GV-AS/EV Controller User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. AS100.110.120.210.400.410.810-EV48-A
DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
WIRELESS INSTRUMENTATION TECHNOLOGY
BS&B WIRELESS, L.L.C. BS&B WIRELESS, L.L.C. WIRELESS INSTRUMENTATION TECHNOLOGY Printed February 2004 BS&B WIRELESS, L.L.C. 7422-B East 46th Place, Tulsa, OK74145 Phone: 918-622-5950 Fax: 918-665-3904
Multifunction devices
devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2
Functional Specification Document
Functional Specification Document Access Control Technology Unit C1 South City Business Centre Tallaght Dublin 24 Ireland Ph: + 353 (0) 1 4662570 Web: www.accesscontrol.ie Index Introduction 1.1 Hardware
USB Plus+ RFID Reader Setup Guide
875-0042-03 RevA USB Plus+ RFID Reader Setup Guide 1 Government Limited Rights Notice: All documentation and manuals were developed at private expense and no part of it was developed using Government funds.
Product Information Fire alarm panel 8000 C
Product Information Fire alarm panel 8000 C Fire alarm panel 8000 C, basic configuration In common with all modern Esser panels, the 8000 C fire alarm panel is based on high-performance ringbus technology.
SMS GSM Alarm Messenger
SMS GSM Alarm Messenger Data Logging Alarm Input Relay Output Voice Temperature Humidity Analog Input Capture and Send Data via SMS Report triggered alarm via SMS Output triggered via SMS Auto pick up
User manual Compact Web PLC WP240 series IEC-line
User manual Compact Web PLC WP240 series IEC-line update: 09-01-2014 IEC-line by OVERDIGIT overdigit.com 1. General description The WP240 device is a PLC, programmable in IEC61131-3 language using CoDeSys
Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
MultiViu Flex 7 Data Sheet
Division Interior MultiViu Flex 7 Data Sheet Picture: MultiViu Flex 7 Picture: MultiViu Flex 7 Description CAN-capable multifunction Solution Features: Robust and versatile design CAN-capability (SAE J1939,
NiceWay. Professional For a more professional and practical use, the system can be programmed by means of the handy Nice palmtops.
NiceWay NiceWay Radio control system to manage the range of Nice automations, such as awnings, rolling shutters, gates and garage doors, from any point within the home. Modular The NiceWay system is based
WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK
WEA-Base User manual for load cell transmitters 1 Contents 1. Technical data... 3 2. Assembly... 4 2.1 Power supply... 4 2.2 Load cells... 4 2.3 RS-485... 4 2.4 Relays... 5 2.5 Digital input... 5 2.6 Analogue
PD 100A. Printing data system
PD 100A Printing data system Operating instructions ENGLISH IMPORTANT: Read these instructions carefully before installing and using the device; do not forget following all additional information. Keep
GSM Alarm System User Manual
GSM Alarm System User Manual For a better understanding of this product, please read this user manual thoroughly before using it. Quick Guider After getting this alarm system, you need to do the following
Operating Instructions
Operating Instructions Kühn Controls AG, Gräfenhäuser Str. 14, D-75305 Neuenbürg, Germany Tel. +49 (0)7082-94 00 00 www.kuehn-controls.de [email protected] Fax +49 (0)7082-94 00 01 Content 1. SMS
How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)
MODEL NUMBER: ISC910-1-0-GB-XX ISC911-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)