1 CENTRIA Exposed Fastener Series Metal Wall Panels CENTRIA Exposed Fastener Series Metal Wall Panels are a versatile design choice for both new and retrofit projects. Exposed Fastener Metal Wall Panels may be installed horizontally or vertically and may be inverted if desired. Panels are available with hot-dip galvanized, Galvalume, or Galvalume Plus coated steel, aluminum and uncoated stainless steel substrates. Exposed Fastener Metal Wall Panels are manufactured with a variety of profiles and surface treatments, which are especially attractive to creative designers. CENTRIA Exposed Fastener Series Metal Wall Panels are manufactured and coated with CENTRIA's own Fluorofinish Kynar 500 or Hylar based fluoropolymer or Versacor corrosion- and abrasionresistant finishes. Highly UV resistant and durable in the face of chemical and air borne pollution, salt spray and wind-driven sand, CENTRIA coatings set the standard for the industry. CENTRIA coatings are available in over 60 standard colors and additional custom colors. CENTRIA metal wall panels may be used as a single-skin application, with metal liner panels, or as the exterior cladding components of a wall assembly that includes CENTRIA MetalWrap insulated core metal wall backup panels providing an insulated substrate complete with moisture, air, and vapor control. CENTRIA Microline trim extrusions, used with 1 1/2-inch-deep horizontal panel profiles, offer the designer an integrated trim system that ensures aesthetic control over the profile of visual components of the wall assembly. CENTRIA MicroSeam mitered trimless corners accentuate horizontal lines. Available Profile Louvers match certain metal wall panel profiles and finishes. Consult your local CENTRIA architectural representative for design assistance. Contact CENTRIA, Pittsburgh, PA, (800) , [email protected], for a list of offices. CENTRIA is a world leader in the manufacture of metal building products and systems for nonresidential walls and roofs. CENTRIA is also a world-class coil coater, coating a wide range of products for customers in numerous industries. CENTRIA products appear in the following MasterFormat sections: Section Metal Roof Panels (SRS3) Section Insulated Core Metal Roof Panels (Versapanel) Section Metal Wall Panels (Cascade Metal Panel System, Intercept V-Trac, Intercept Entyre, Paradigm, Concept Series, IW Series, Exposed Fastener Panels) Section Insulated-Core Metal Wall Panels (Formawall Dimension Series, Formawall Graphix Series, Versawall, Versapanel, Foamwall, VersaShield MW) Section Insulated Composite Backup Panel (MetalWrap) Section Composite Wall Panels (FormaBond) Specifier: This document is organized according to CSI MasterFormat. Edit section number and title as appropriate to the Project. Bold items require specifier selection. Convert bold to plain text and delete notes before publishing Exposed Fastener Series, Microline, and MetalWrap are trademarks of CENTRIA, INC. Page 1 of 18

2 Fluorofinish and MicroSeam are a registered trademarks of CENTRIA, Inc. Galvalume and Galvalume Plus are registered trademarks of BIEC International, Inc. Kynar 500 is a registered trademark of Arkema, Inc. Hylar 5000 is a registered trademark of Solvay S.A. MasterFormat is a trademark of the Construction Specifications Institute. This document is Copyright 2014 CENTRIA. All rights reserved. Page 2 of 18

3 SECTION METAL WALL PANELS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Exposed fastener metal wall panels, [and liner panels] as part of the assembly described in Section RELATED REQUIREMENTS Specifier: Edit list below to correspond to Project. A. Division 01 Section "Sustainable Design Requirements" for related requirements. B. Division 07 Section "Sheet Metal Flashing and Trim" for sheet metal copings, flashings, reglets and roof drainage items. C. Division 07 Section "Joint Sealants" for field-applied joint sealants. 1.3 REFERENCES A. American Architectural Manufacturer's Association (AAMA): 1. AAMA Voluntary Specification for High Performance Organic Coatings on Coil Coated Architectural Aluminum Substrates. 2. AAMA Voluntary Specification for High Performance Organic Coatings on Coil Coated Architectural Hot Dipped Galvanized (HDG) and Zinc-Aluminum Coated Steel Substrates. B. American Society of Civil Engineers (ASCE): 1. ASCE 7 - Minimum Design Loads for Buildings and Other Structures. C. ASTM International (ASTM): 1. ASTM A 653/A 653M - Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc- Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process. 2. ASTM A 666 Standard specification for Annealed or Cold-Worked Austenitic Stainless Steel Sheet, Strip, Plate, and Flat Bar. 3. ASTM A 755/A 755M - Specification for Steel Sheet, Metallic Coated by the Hot-Dip Process and Prepainted by the Coil-Coating Process for Exterior Exposed Building Products. 4. ASTM A 792/A 792M Standard specification for Steel Sheets, 55% Aluminum Zinc Alloy. Coated by hot-dip process. 5. ASTM B Specification for Aluminum and Aluminum Alloy Sheet and Plate. 6. ASTM C Specification for Installation of Steel Framing Members to Receive Screw Attached Gypsum Panel Products. Page 3 of 18

4 7. ASTM C Specification for Elastomeric Joint Sealants. 8. ASTM E 72 - Standard Test Methods of Conducting Strength Tests of Panels for Building Construction. 9. ASTM E Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors under Specified Pressure Differences across the Specimen. 10. ASTM E Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference. D. Sheet Metal and Air Conditioning Contractors National Association, Inc. (SMACNA): 1. Architectural Sheet Metal Manual. 1.4 PERFORMANCE REQUIREMENTS Specifier: Contractor. Add requirements to this Article if Project requirements include delegated design by A. General: Provide metal wall panel assemblies meeting performance requirements as determined by application of specified tests by a qualified testing agency on manufacturer's standard assemblies. B. Air Infiltration: When installed over Insulated Composite Backup Panels or Metal Liner Panels, maximum 0.06 cfm/sq. ft. (0.3 L/s per sq. m) per ASTM E 283 at a static-air-pressure difference of 1.57 lbf/sq. ft. (75 Pa), using minimum 10-by-10 foot (3050-by-3050 mm) test panel that includes side joints. C. Water Penetration, Static Pressure: When installed over Insulated Composite Backup Panels or Metal Liner Panels, no uncontrolled water penetration per ASTM E 331 at a minimum static differential pressure of 6.24 lbf/sq. ft. (299 Pa), using minimum 10-by-10 foot (3050-by mm) test panel that includes side joints. D. Florida State Building Code Compliance: Provide wall panels that comply with the requirements for installation under Florida State Building Code aside of the High Velocity Hurricane Zone. E. Maximum allowable deflection limitation. Specifier: CENTRIA recommends minimum 22 gage metal wall panels for enhanced structural performance and optimum aesthetic appearance. CENTRIA exposed fastener metal wall panels, except Super Rib, and liner panels are also available in 24 gage. Specifier: Select one of the following three subparagraphs based upon the selected panel depth and configuration. 1. Single Skin Panels Less than 1-inch (25-mm) in Depth: Limited to L/90 deflection of panel perimeter normal to plane of wall. 2. Single Skin Panels greater than 1-inch (25-mm) in Depth: Limited to L/120 deflection of panel perimeter normal to plane of wall. 3. All Exposed Fastener Series panels specified with Liner Panels: Limited to L/180 deflection of panel perimeter normal to plane of wall. Page 4 of 18

5 F. Secondary Metal Framing: Design secondary metal framing for metal wall panel assembly according to AISI's "Standard for Cold-Formed Steel Framing - General Provisions." Specifier: For horizontal applications, and other applications where thermal movement is an issue, retain the requirements below. G. Thermal Movements: Allow for thermal movements from variations in both ambient and internal temperatures. Accommodate movement of support structure caused by thermal expansion and contraction. Specifier: Retain paragraph below if foam plastic insulation is included within the wall system. H. Wall systems that incorporate foam plastic insulation must be tested by the foam plastic supplier in accordance with NFPA QUALITY ASSURANCE A. Manufacturer/Source: Provide metal wall panel and panel accessories from a single manufacturer. Specifier: Retain paragraph below if Owner allows substitutions but requires strict control over qualifying of substitutions. B. Manufacturer Qualifications: Approved manufacturer listed in this Section with minimum 10 years experience in manufacture of similar products in successful use in similar applications. 1. Approval of Comparable Products: Submit the following in accordance with project substitution requirements, within time allowed for substitution review: a. Product data, including certified independent test data indicating compliance with requirements. b. Samples of each component. c. Project references: Minimum of 5 installations not less than 5 years old, with Owner and Architect contact information. d. Sample warranty. 2. Substitutions following award of contract are not allowed except as stipulated in Division 01 General Requirements. 3. Approved manufacturers must meet separate requirements of Submittals Article. C. Wall Systems Installer Qualifications: Experienced Installer with minimum of 5 years experience with successfully completed projects of a similar nature and scope. 1.6 ADMINISTRATIVE REQUIREMENTS A. Preinstallation Meeting: Conduct preinstallation meeting at site attended by Owner, Architect, manufacturer's representative, and other trade contractors. 1. Coordinate building framing in relation to metal wall panel assembly. 2. Coordinate installation of building air and water barrier behind metal wall panel assembly. 3. Coordinate window, door and louver, and other openings and penetrations of metal wall panel assembly. Page 5 of 18

6 1.7 ACTION SUBMITTALS A. Product Data: Manufacturer s data sheets, for specified products. 1. Include data indicating compliance with performance requirements. B. Shop Drawings: Provide shop drawings prepared by manufacturer or manufacturer's authorized Installer. Include full elevations showing openings and penetrations. Include details of each condition of installation and attachment. Provide details at a minimum scale 1-1/2-inch per foot (1:8) of all required trim and extrusions needed for a complete installation. 1. Indicate points of supporting structure that must coordinate with metal wall panel assembly installation. C. Samples for Initial Selection: For each product specified. Provide representative color charts of manufacturer's full range of colors. D. Samples for Verification: Provide 12-inch (300 mm) section of panel(s) showing finishes. Provide 12-inch (300 mm) long pieces of trim pieces and other exposed components. 1.8 INFORMATIONAL SUBMITTALS A. Product Test Reports: Indicating compliance of products with requirements, from a qualified independent testing agency. Specifier: Retain paragraphs below when Project requirements include compliance with Federal Buy American provisions. CENTRIA Metal Wall Panels comply with requirement. B. Buy American Act Certification: Submit documentation certifying that products comply with provisions of the Buy American Act 41 U.S.C 10a 10d. Specifier: Retain below when authorities having jurisdiction require certification for high velocity hurricane zone. C. Dade County Approval, Dade County Notice of Acceptance (NOA). Style-Rib, MR3-36 & Super- Rib only in 20 gage minimum. D. State of Florida High Velocity Hurricane Zone, (HVHZ). Style-Rib only in 20 gage minimum. E. Qualification Information: For Installer firm. F. Manufacturer's warranty: Submit sample warranty. 1.9 CLOSEOUT SUBMITTALS A. Maintenance data DELIVERY, STORAGE, AND HANDLING A. Protect metal wall panel products during shipping, handling, and storage to prevent staining, denting, deterioration of components or other damage. Page 6 of 18

7 1. Deliver, unload, store, and erect metal wall panel products and accessory items without misshaping panels or exposing panels to surface damage from weather or construction operations WARRANTY Specifier: Warranty terms below are available from CENTRIA. Verify that other allowable manufacturers furnish warranty meeting requirements. A. Special Manufacturer s Warranty: On manufacturer s standard form, in which manufacturer agrees to repair or replace components of metal wall panel assemblies that fail in materials and workmanship within [two] years from date of Substantial Completion. Specifier: Consult CENTRIA representative to verify available finish warranty. B. Special Panel Finish Warranty: On manufacturer s standard form, in which manufacturer agrees to repair or replace metal wall panels that display evidence of deterioration of finish within [20] years from the date of substantial completion. PART 2 - PRODUCTS 2.1 SYSTEM DESCRIPTION Specifier: Retain one or more of six wall system descriptions below that correspond to Project Requirements; edit as required. System (A) below describes installation of metal wall panels over CENTRIA MetalWrap backup system. A. Metal Wall Panels over Insulated-Composite Backup Panel Wall System: Single-skin exposed fastener metal wall panels serving as the exterior rainscreen cladding component of a metal wall panel system that includes insulated composite metal wall backup panels specified in Division 07 Section "Insulated-Composite Backup Panel System." Metal wall backup panels provide thermal, air, water, and water vapor control. Metal wall panel installation specified in this Section includes secondary metal subgirt framing for panel attachment. B. Metal Wall Panels and Metal Liner Panel Wall System: Single-skin exposed fastener metal wall panels applied as the exterior cladding over wall framing specified in [Division 05 Section "Cold-Formed Metal Framing" ] [Division 13 Section "Metal Building Systems" ]with board insulation and metal liner panels. Metal wall panel installation specified in this Section includes secondary metal subgirt framing for panel attachment and an interior sealed-joint metal liner panel that provides air and water vapor control. 1. Water-resistive barrier is required for Horizontal Liner applications and is under Division 07 Section "Weather Barriers." C. Metal Wall Panels over Multi-Component Framed Wall System: Single-skin exposed fastener metal wall panels applied as exterior rainscreen cladding over wall framing specified in Division 05 Section "Cold-Formed Metal Framing" with exterior sheathing specified in Division 06 Section "Sheathing", an applied membrane that provides air, moisture, and water vapor control specified in Division 07 Section "Air Barriers", and insulation within the framing specified Page 7 of 18

8 in Division 07 Section "Thermal Insulation." Metal wall panel installation specified in this Section includes secondary metal subgirt framing for panel attachment. Specifier: Retain subparagraphs below. Product is not by CENTRIA. 1. Air, moisture, and water vapor control membrane is provided under Division 07 Section "Air Barriers." D. Metal Wall Panels over Outside-Insulated Framed Wall System: Single-skin exposed fastener metal wall panels applied as exterior rainscreen cladding over wall framing specified in Division 05 Section "Cold-Formed Metal Framing" with exterior sheathing specified in Division 06 Section "Sheathing", an applied membrane that provides air, moisture, and water vapor control specified in Division 07 Section "Air Barriers", and insulation [within the framing and] applied outboard of the sheathing specified in Division 07 Section "Thermal Insulation." Metal wall panel installation specified in this Section includes secondary metal subgirt framing for panel attachment. Specifier: Retain subparagraphs below. Product is not by CENTRIA. 1. Air, moisture, and water vapor control membrane is provided under Division 07 Section "Air Barriers." E. Metal Wall Panels over Masonry Wall System: Single-skin exposed fastener metal wall panels applied as exterior rainscreen cladding over a masonry wall [and rigid board insulation] specified in Division 04 Section "Unit Masonry" and an applied membrane that provides air, moisture, and water vapor control specified in Division 07 Section "Air Barriers." Metal wall panel installation specified in this Section includes secondary metal subgirt framing for panel attachment. Specifier: Retain subparagraphs below for horizontal panels. Product is not by CENTRIA. 1. Air, moisture, and water vapor control membrane is provided under Division 07 Section "Air Barriers." F. Metal Wall Panels over Uninsulated Framed [Screen] Wall System: Single-skin exposed fastener metal wall panels applied as exterior barrier cladding over wall framing specified in [Division 05 Section "Cold-Formed Metal Framing" ] [Division 13 Section "Metal Building Systems" ] [and water-resistive barrier specified in Division 07 Section "Weather Barriers"]. Metal wall panel installation specified in this Section may include secondary metal subgirt framing for panel attachment. 2.2 MANUFACTURERS A. Basis of Design: CENTRIA, Exposed Fastener Series Metal Wall Panels. Provide basis of design product [, or comparable product approved by Architect prior to bid]. 1. CENTRIA Architectural Systems; Moon Township, PA Tel: (800) Tel: (412) Fax: (412) [email protected]. Web: Page 8 of 18

9 2.3 METAL WALL PANEL MATERIALS Specifier: Select metal wall panel face material from three paragraphs below. Aluminum-zinc alloycoated steel sheet, Galvalume, Galvalume Plus with a thin, clear acrylic topcoat, is also available and is recommended for uniform weathering when specified without an applied paint finish. A. Metallic-Coated Steel Face Sheet: Coil-coated, ASTM A 755/A 755M. 1. Zinc-Coated (Galvanized) Steel Sheet: ASTM A 653/A 653M, G90 (Class Z275), structural steel quality. 2. Aluminum-zinc alloy-coated (Galvalume) Steel Sheet: ASTM A 792/A 792 M, Class AZ50 Grade 50 (Class AZM150, Grade 275), structural steel quality. Specifier: Select required metal face sheet thickness from options below. Specifier: CENTRIA recommends minimum 22 gage metal wall panels for enhanced structural performance and optimum aesthetic appearance. CENTRIA exposed fastener metal wall panels, except Super Rib, and liner panels are also available in 24 gage. 3. Face Sheet: Minimum [0.024 inch/24 gage (0.60 mm)] [0.030 inch/22 gage (0.76 mm)] [0.036 inch/20 gage (0.91 mm)] [0.047 inch/18 gage (1.19 mm)] nominal uncoated thickness. 4. Surface: [Smooth] [Non-Directional Embossed]. B. Aluminum Face Sheet: Smooth surface coil-coated, ASTM B 209, 3003-H14 or 5052-H32 alloy. Specifier: Select required metal face sheet thickness from options below. 1. Face Sheet: [0.032 inch (0.8 mm)] [0.040 inch (1.0 mm)] [0.050 inch (1.27 mm)] nominal thickness. 2. Surface: [Smooth] [Non-Directional Embossed]. C. Stainless-Steel Face Sheet: ASTM A 666, architectural grade alloy type as indicated. Specifier: Select required metal face sheet thickness from options below inch/24 gage (0.60 mm) thickness is available in CENTRIA CS-260/260E and CS 660/660E panels. 1. Face Sheet: [0.024 inch/24 gage (0.60 mm)] [0.030 inch/22 gage (0.76 mm)] [0.036 inch/20 gage (0.91 mm)] nominal thickness. Specifier: Type 316 alloy is recommended for marine and other corrosive environments. 2. Finish: [Type 304, #4 Brushed], [Type 316, #4 Brushed]. 2.4 EXPOSED FASTENER PROFILE METAL WALL PANELS Specifier: CENTRIA EXPOSED FASTENER metal wall panels are suitable for horizontal and vertical installation. Continuous shims provide a ventilated cavity and a drain plane behind panels when required. Standard lengths are 5 to 40 feet; custom length panels are available on special order. Page 9 of 18

10 Specify optional field-applied sealant in vertical panel side laps when added water resistance is required. CENTRIA recommends a complete water-resistant barrier behind horizontal panels. If using more than one metal wall panel, retain the drawing designation below for each panel. If metal types, thicknesses, surfaces, or finish systems differ, add notes below to indicate the metal type, thickness, surface, and finish for each panel on project. A. Metal Wall Panels, General: Factory-formed, Exposed fastener panels with interconnecting side joints, fastened to supports with exposed fasteners, with field-applied sealants in side laps when required to meet performance requirements. B. Ribbed profile with lap joint MWP# : 1. Basis of Design Product: CENTRIA, BR Panel Coverage: 36 inches (914 mm). 3. Panel Height: 1.50 inches (38 mm). 4. Rib Spacing: 5 at 7.20 inches (183 mm) o.c. C. Ribbed profile with lap joint MWP# : 1. Basis of Design Product: CENTRIA, MR Panel Coverage: 36 inches (914 mm). 3. Panel Height: 3.0 inches (76 mm). 4. Rib Spacing: 3 at 12 inches (305 mm) o.c. D. Ribbed profile with raised pans with lap joint MWP# : 1. Basis of Design Product: CENTRIA, TR Panel Coverage: 36 inches (914 mm). 3. Panel Height: 1.50 inches (38 mm). 4. Rib Spacing: 4 at 9 inches (229 mm) o.c. E. Symmetrical corrugated profile with lap joint. MWP# : 1. Basis of Design Product: CENTRIA, Econolap 3/4 inch. 2. Panel Coverage: inches (880 mm). 3. Panel Height: 0.75 inches (19 mm). 4. Corrugation Spacing: 2.66 inches (68 mm) o.c. F. Symmetrical corrugated profile with lap joint MWP# : 1. Basis of Design Product: CENTRIA, Econolap 1/2 inch. 2. Panel Coverage: inches (948 mm). 3. Panel Height: 0.50 inches (13 mm). 4. Corrugation Spacing: 2.66 inches (68 mm) o.c. G. Symmetrical deep rib profile with lap joint MWP# : 1. Basis of Design Product: CENTRIA, Super-Rib. 2. Panel Coverage: 24 inches (610 mm). 3. Panel Height: 4 inches (102 mm). 4. Rib Spacing: 12 inches (305 mm) o.c. Page 10 of 18

11 H. Symmetrical rib profile with lap joint MWP# : 1. Basis of Design Product: CENTRIA, Style-Rib. 2. Panel Coverage: 36 inches (914 mm). 3. Panel Depth: 1.50 inches (38 mm). 4. Rib Spacing: 5 at 7.2 inches (183 mm) o.c. Specifier: Select metallic-coated steel face sheet or aluminum face sheet finish system from options below. AAMA 620 is aluminum sheet finish standard; AAMA 621 is metallic-coated steel sheet finish standard. Delete all finish options if specifying stainless steel face sheet. A. Exposed Coil-Coated Finish System: 1. Fluoropolymer Two-Coat System: 0.2 mil primer with 0.8 mil 70 percent PVDF fluoropolymer color coat, AAMA [620] [621]. a. Basis of Design: CENTRIA Fluorofinish. 2. Fluoropolymer Two-Coat System: 0.8 mil primer with 0.8 mil 70 percent PVDF fluoropolymer color coat, AAMA [620] [621]. a. Basis of Design: CENTRIA Duragard. 3. Fluoropolymer Three-Coat System: 0.8 mil primer with 0.8 mil 70 percent PVDF fluoropolymer color coat, and a 0.8 mil 70 percent PVDF fluoropolymer clear coat, AAMA [620] [621]. a. Basis of Design: CENTRIA Duragard Plus. 4. Fluoropolymer Two-Coat Mica System: 0.25 mil primer with 0.8 mil 70 percent PVDF fluoropolymer color coat providing a pearlescent appearance, AAMA [620] [621]. a. Basis of Design: CENTRIA Sundance Mica. 5. Fluoropolymer Three-Coat Metallic System: 0.2 mil primer with 0.8 mil 70 percent PVDF fluoropolymer color coat containing metal flakes, and a 0.5 mil 70 percent PVDF fluoropolymer clear coat, AAMA [620] [621]. a. Basis of Design: CENTRIA Sundance AM. Specifier: The three CENTRIA Versacor systems below are recommended for corrosive and abusive environments. Select system and one of three options for panel interior finish based on exposure and environmental conditions. Consult CENTRIA representative for recommended finish system. 6. Fluoropolymer Two-Coat Corrosion and Abrasion Resistant System: 2.0 mil barrier coat primer with 0.8 mil 70 percent PVDF fluoropolymer color coat. a. Basis of Design: CENTRIA Versacor Elite PF. 7. Fluoropolymer Two-Coat Corrosion and Abrasion Resistant System: 2.0 mil barrier coat primer with 0.8 mil 70 percent PVDF fluoropolymer color coat that includes mica flakes that provides a pearlescent appearance. Page 11 of 18

12 B. Color: a. Basis of Design: CENTRIA Versacor Elite MX. 8. Fluoropolymer Two-Coat Corrosion and Abrasion Resistant System: 2.0 mil barrier coat primer with 0.8 mil 70 percent PVDF fluoropolymer color coat that includes aluminum metal flakes, with a 0.5 mil PVDF clear topcoat. b. Basis of Design: CENTRIA Versacor Elite AM. 9. Fluoropolymer Three Coat System: 0.2 mil primer with a 0.5 mil polyester base coat and a 0.8 mil nominal PVDF fluoropolymer top coat providing an iridescent finish. a. Basis of Design: CENTRIA KolorShift. 10. Fluoropolymer Three Coat System: 0.65 mil color base coat and Primer with a 0.05 mil PVDF ink coat and a 0.45 nominal PVDF fluoropolymer clear coat. a. Basis of Design: CENTRIA Allusion. 11. Fluoropolymer Two Coat System: 0.2 mil primer with a 0.8 mil PVDF matte, low gloss color coat with fine aggregate finish. a. Basis of Design: CENTRIA Allura. Specifier: Retain one or both subparagraphs below has required for Project. 1. Exterior Surface: [As indicated] [As selected by Architect from manufacturer's standard colors] [Match Architect's custom color]. 2. Interior Surface: [Manufacturer's standard primer color] [As indicated] [As selected by Architect from manufacturer's standard colors] [Match Architect's custom color]. 2.5 LINER PANELS Specifier: Retain this Article if liner panel is required on interior of assemblies. Standard lengths are 5 to 30 feet; custom length panels are available on special order. Deeper assemblies may be used in conjunction with thicker insulation. A. Metal Liner Panels, General: Factory-formed panels with interconnecting side joints, fastened to supports with exposed fasteners. 1. [Zinc-Coated (Galvanized) steel sheet] [Aluminum-zinc alloy-coated (Galvalume) steel sheet]. 2. Face Sheet: Minimum [0.024 inch/24 gage (0.60 mm)] [0.030 inch/22 gage (0.76 mm)] [0.036 inch/20 gage (0.91 mm)] [0.047 inch/18 gage (1.19 mm)] nominal uncoated thickness. 3. Panel Sheet: [Solid] [Perforated, with 10 percent free area]. 4. Surface: [Smooth] [Non-Directional Embossed]. B. Metal liner panel MLP# : 1. Basis of Design Product: CENTRIA, L2. Page 12 of 18

13 2. Panel Coverage: 24 inches (610 mm). 3. Panel Height: inches (35 mm). 4. Stiffening Beads: Two. C. Metal liner panel MLP# : 1. Basis of Design Product: CENTRIA, L Panel Coverage: 24 inches (610 mm). 3. Panel Height: 2 inches (50 mm). 4. Stiffening Beads: Two. D. Metal liner panel MLP# : 1. Basis of Design Product: CENTRIA, L Panel Coverage: 24 inches (610 mm). 3. Panel Height: 3 inches (76 mm). 4. Stiffening Beads: Two. E. Exposed Coil-Coated Finish System: 1. Fluoropolymer Two-Coat System: 0.2-mil primer with 0.8 mil 70 percent PVDF fluoropolymer color coat, AAMA 621. a. Basis of Design: CENTRIA Fluorofinish. 2. Fluoropolymer Two-Coat System: 0.8 mil primer with 0.8 mil 70 percent PVDF fluoropolymer color coat, AAMA 621. a. Basis of Design: CENTRIA Duragard. 3. Fluoropolymer Three-Coat System: 0.8 mil primer with 0.8 mil 70 percent PVDF fluoropolymer color coat, and a 0.8 mil 70 percent PVDF fluoropolymer clear coat, AAMA 621. a. Basis of Design: CENTRIA Duragard Plus. 4. Fluoropolymer Two-Coat Mica System: 0.25 mil primer with 0.8 mil 70 percent PVDF fluoropolymer color coat providing a pearlescent appearance, AAMA 621. a. Basis of Design: CENTRIA Sundance Mica. 5. Fluoropolymer Three-Coat Metallic System: 0.2 mil primer with 0.8 mil 70 percent PVDF fluoropolymer color coat containing metal flakes, and a 0.5 mil 70 percent PVDF fluoropolymer clear coat, AAMA 621. a. Basis of Design: CENTRIA Sundance AM. Specifier: The three CENTRIA Versacor systems below are recommended for corrosive and abusive environments. Select system and one of three options for panel interior finish based on exposure and environmental conditions. Consult CENTRIA representative for recommended finish system. 6. Fluoropolymer Two-Coat Corrosion and Abrasion Resistant System: 2.0 mil barrier coat primer with 0.8 mil 70 percent PVDF fluoropolymer color coat. Page 13 of 18

14 F. Color: b. Basis of Design: CENTRIA Versacor Elite PF. 7. Fluoropolymer Two-Coat Corrosion and Abrasion Resistant System: 2.0 mil barrier coat primer with 0.8 mil 70 percent PVDF fluoropolymer color coat that includes mica flakes that provides a pearlescent appearance. c. Basis of Design: CENTRIA Versacor Elite MX. 8. Fluoropolymer Two-Coat Corrosion and Abrasion Resistant System: 2.0 mil barrier coat primer with 0.8 mil 70 percent PVDF fluoropolymer color coat that includes aluminum metal flakes, with a 0.5 mil PVDF clear topcoat. d. Basis of Design: CENTRIA Versacor Elite AM. 9. Fluoropolymer Three Coat System: 0.2 mil primer with a 0.5 mil polyester base coat and a 0.8 mil nominal PVDF fluoropolymer top coat providing an iridescent finish. b. Basis of Design: CENTRIA KolorShift. 10. Fluoropolymer Three Coat System: 0.65 mil color base coat and Primer with a 0.05 mil PVDF ink coat and a 0.45 nominal PVDF fluoropolymer clear coat. a. Basis of Design: CENTRIA Allusion. 11. Fluoropolymer Two Coat System: 0.2 mil primer with a 0.8 mil PVDF matte, low gloss color coat with fine aggregate finish. a. Basis of Design: CENTRIA Allura. Specifier: Retain one or both subparagraphs below has required for Project. 1. Interior Exposed Surface: [As indicated] [As selected by Architect from manufacturer's standard colors] [Match Architect's custom color]. 2. Concealed Surface: Manufacturer's standard primer color. 2.6 METAL WALL PANEL ACCESSORIES Specifier: Retain paragraph below when metal wall panels are used in conjunction with CENTRIA MetalWrap metal wall panel backup system, which provides a one-step insulated substrate incorporating watertight joints and air/vapor control. A. Metal Wall Panel Backup System: Refer to Division 07 Section "Insulated-Composite Backup Panel System." B. Metal Wall Panel Accessories, General: Provide complete metal wall panel assembly incorporating trim, copings, fasciae, parapet caps, soffits, sills, inside and outside corners, and miscellaneous flashings. Fabricate accessories in accordance with SMACNA Manual. Provide manufacturer's factory-formed clips, shims, flashings, gaskets, lap strips, closure strips, and caps for a complete installation as required for the following: Page 14 of 18

15 Specifier: Select and edit appropriate installation description below. 1. Single-skin application over metal framing [and secondary framing] with liner panels. 2. Single-skin application over insulated, sheathed frame wall with air and water resistant barrier. 3. Single-skin application over furred masonry backup with air and water resistant barrier. 4. Multi-component wall system, consisting of metal wall panel application over insulated core metal wall panel backup system. Specifier: CENTRIA offers Microline Extrusions, an extensive line of extruded trims that integrate both visually and mechanically with CENTRIA Exposed Fastener panels that are available for horizontal applications of CENTRIA Style Rib, BR5-36, Econolap ¾, and TR4-36 panels. C. Extruded Trim: Manufacturer's complementary aluminum extrusions for head, jamb, sill, base, flush, reveal, inside and outside corner, end wall, and expansion joint details. Finish to match metal wall panels. 1. Basis of Design: CENTRIA, Microline Extrusions. Specifier: CENTRIA offers MicroSeam Corners, a popular design feature that accentuates horizontal lines by eliminating trim at corners. MicroSeam corners are not available for Econolap ½. D. Mitered Corners: Structurally-bonded horizontal interior and exterior trimless corners matching metal wall panel material, profile, and factory-applied finish, fabricated and finished by metal wall panel manufacturer. 1. Welded, riveted, fastened, or field- fabricated corners do not meet the requirements of this specification. 2. Basis of Design: CENTRIA, MicroSeam Corners. E. Formed Flashing and Trim: Match material, thickness, and color of metal wall panel face sheets. F. Sealants: Type recommended by metal wall panel manufacturer for application, meeting requirements of Division 07 Section "Joint Sealants." G. Flashing Tape: 4-inch wide self-adhering butyl flashing tape. H. Fasteners: Self-tapping screws, bolts, nuts, and other acceptable fasteners recommended by panel manufacturer. All exposed fasteners must be stainless steel with heads matching color of metal wall panels by means of factory-applied coating. Specifier: CENTRIA offers Profile Louvers that are configured to match horizontally-oriented Exposed Fastener Series panel profiles. Profile matching louvers are available for BR5-36, MR3-36, Style-Rib and Super-Rib panels. 2.7 WALL LOUVER UNITS A. Wall Louvers, General: Metal louvers, designed to integrate with metal wall panel profile and secondary support system without receptor channels or other flashing, of types and performance indicated. Provide manufacturer's standard louver blade clips matching panel color. Page 15 of 18

16 Specifier: Select options and edit below as required for Project. Coordinate with HVAC engineer. Indicate size on Drawings. B. Horizontal Fixed Louver: 1. Louver Size: As indicated on Drawings. 2. Louver Depth: Various options depending on free area requirements 3. Free Area: Depending on profile and depth 4. Air Performance: Not exceeding (0.10-inch wg (25-Pa)) static pressure drop at 600-fpm (3.0-m/s) free area velocity. C. Base Metal and Finish: 1. Match metal wall panel base metal and finish. Specifier: Retain paragraph below if required, and select screen type. Bird screen is typically required; insect screen requires maintenance to ensure air flow. D. Louver Screens: Mounted in removable aluminum frame. 1. Bird Screen: 1/2-inch (12 mm) mesh aluminum, crimped. 2. Insect Screen: mesh aluminum, crimped. 2.8 SECONDARY METAL FRAMING A. Miscellaneous Framing Components, General: Cold-formed metallic-coated steel sheet, ASTM A 653/A 653M, G90 (Z180). 1. Hat Channels: 0.06 inch/16 ga. (1.52 mm) minimum nominal thickness. 2. Sill Channels: 0.06 inch/16 ga. (1.52 mm) minimum nominal thickness. PART 3 - EXECUTION 3.1 EXAMINATION A. Examine metal wall panel substrate with Installer present. Inspect for erection tolerances and other conditions that would adversely affect installation of metal wall panels. B. Wall Substrate: Confirm that wall substrate is within tolerances acceptable to metal wall panel system manufacturer. 1. Maximum deviations acceptable: a. 1/4-inch in 20 feet (6.4 mm in 6 m) vertically or horizontally from face plane of framing. b. 1/2-inch (12.7 mm) across building elevation. c. 1/8-inch in 5 feet (3.2 mm in 1.5 m). Specifier: Retain one, two, or three following paragraphs as appropriate to Project. C. Framing: Inspect framing that will support metal wall panels to determine if support components are installed as indicated on approved shop drawings. Confirm presence of Page 16 of 18

17 acceptable framing members at recommended spacing to match installation requirements of metal wall panels. D. Openings: Verify that windows, doors, louvers and other penetrations match layout on shop drawings. E. Air/Moisture Barriers: Confirm that work has been completed, inspected, and tested as required. F. Advise G.C, in writing, of out-of-tolerance work and other deficient conditions prior to proceeding with metal wall panel system installation. G. Correct out of tolerance work and other deficient conditions prior to panel installation. 3.2 SECONDARY FRAMING INSTALLATION Specifier: Retain article only if secondary framing is part of work of this Section. A. Secondary Metal Framing: Install secondary metal framing components to tolerances indicated, as shown on approved shop drawings. Install secondary metal framing and other metal panel supports per ASTM C 1007 and metal wall panel manufacturer's recommendations. 3.3 METAL WALL PANEL INSTALLATION A. General: Install metal wall panels in accordance with approved shop drawings and manufacturer's recommendations. Install metal wall panels in orientation, sizes, and locations indicated. Anchor metal wall panels and other components securely in place. B. Attach panels to metal framing using recommended screws, fasteners, sealants, and adhesives indicated on approved shop drawings. 1. Fasteners for Steel Wall Panels: Stainless-steel for exterior locations and locations exposed to moisture; carbon steel for interior use only. 2. Provide weatherproof escutcheons for pipe and conduit penetrating exterior walls. 3. Dissimilar Materials: Where elements of metal wall panel system will come into contact with dissimilar materials, treat faces and edges in contact with dissimilar materials as recommended by manufacturer. C. Joint Sealers: Install joint sealants where indicated on approved shop drawings. 3.4 ACCESSORY INSTALLATION A. General: Install metal wall panel accessories with positive anchorage to building. Coordinate installation with flashings and other components. 1. Install related flashings and sheet metal trim per requirements of Division 07 Section "Sheet Metal Flashing and Trim." 2. Install components required for a complete metal wall panel assembly, including trim, copings, corners, lap strips, flashings, sealants, fillers, closure strips, and similar items. 3. Comply with performance requirements and manufacturer's written installation instructions. 4. Set units true to line and level as indicated. Page 17 of 18

18 3.5 FIELD QUALITY CONTROL Specifier: Retain paragraph below when scope and complexity of metal wall panel installation justifies inspection expense. A. Manufacturer's Field Service: Engage a service representative authorized by metal wall panel manufacturer to inspect completed installation. Submit written report. B. Correct deficiencies noted in manufacturer's report. 3.6 CLEANING AND PROTECTION A. Remove temporary protective films. Clean finished surfaces as recommended by metal wall panel manufacturer. Clear weep holes and drainage channels of obstructions, dirt, and sealant. Maintain in a clean condition during construction. B. Replace damaged panels and accessories that cannot be repaired by finish touch-up or minor repair. END OF SECTION Page 18 of 18

CENTRIA FORMABOND Metal Composite Wall System

CENTRIA FORMABOND Metal Composite Wall System CENTRIA FORMABOND Metal Composite Wall System CENTRIA FormaBond is the only true metal composite panel wall system designed, manufactured and fabricated by a single, reliable national manufacturer and

More information

CENTRIA SRS3 Structural Standing Seam Metal Roof Panels

CENTRIA SRS3 Structural Standing Seam Metal Roof Panels CENTRIA SRS3 Structural Standing Seam Metal Roof Panels CENTRIA SRS3 Structural Standing Seam Metal Roof Panels are manufactured in many different coil coating systems and painted with a wide variety of

More information

SECTION 07410 PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK

SECTION 07410 PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK SECTION 07410 PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK A. This section covers the pre-finished, pre-fabricated Architectural standing seam roof system. All metal trim,

More information

Holiday Inn Express & Suites Covington (Newton County) 1. Standing-seam metal roofing, custom fabricated.

Holiday Inn Express & Suites Covington (Newton County) 1. Standing-seam metal roofing, custom fabricated. PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Standing-seam metal roofing, custom fabricated. 1.2 SUBMITTALS A. Product Data: For each type of product indicated. B. Shop Drawings: Show installation

More information

SECTION 07 61 13 STANDING SEAM METAL ROOFING

SECTION 07 61 13 STANDING SEAM METAL ROOFING SECTION 07 61 13 STANDING SEAM METAL ROOFING PART 1 GENERAL 1.01 SCOPE OF WORK A. The Work shall include all labor, materials, equipment and supervision required to complete the work of the above referenced

More information

GUIDELINE SPECIFICATIONS

GUIDELINE SPECIFICATIONS GUIDELINE SPECIFICATIONS GORDON SOFFIT-SHIELD - An Exterior Metal Soffit System DIVISION 05 5800 or DIVISION 07 7700 Note To Specifier: SOFFIT-SHIELD should be installed by tradesmen that are experienced

More information

SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING

SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING PART ONE GENERAL DESCRIPTION This section includes pre-formed standing seam metal roofing and related flashings, closures, trim and accessories including,

More information

SECTION 07 42 13 METAL WALL PANELS

SECTION 07 42 13 METAL WALL PANELS Mitsubishi Plastics Composites America, Inc. 401 Volvo Parkway Chesapeake, VA 23320 Phone: (800) 422-7270 Fax: (757) 436-1896 E-mail: [email protected] www.alpolic-northamerica.com This MANU-SPEC utilizes

More information

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood Section 07411 Metal Roof Panels Part 1 General 1.1 Summary A. This section includes the following: a. Factory-formed

More information

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023 Specifications Preformed Metal Wall and Roof Panels Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023 Section 07410 Preformed Metal Wall and Roof Panels Structural

More information

SECTION 07411 STANDING SEAM METAL ROOFING

SECTION 07411 STANDING SEAM METAL ROOFING PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following: 1. Standing-seam metal roof. 2. Metal gutters. 1.2 DEFINITIONS A. Metal Roof Panel Assembly: Metal roof panels, waterproofing membrane (underlayment),

More information

SECTION 07410 METAL ROOF & WALL PANELS

SECTION 07410 METAL ROOF & WALL PANELS This document specifies Metal Roofing Systems prefinished factory formed metal roofing marketed as MRS System 2500 steel and aluminum roofing systems and includes MRS flashing and Trim. MRS finish is a

More information

PART 1 GENERAL 1.1 SECTION INCLUDES

PART 1 GENERAL 1.1 SECTION INCLUDES J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including

More information

A. Double lock standing seam, single element, metal roof panels.

A. Double lock standing seam, single element, metal roof panels. Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions SECTION 07 41 13 METAL ROOF PANELS Morin Metal Panels Double Lock Standing Seam Metal Roof Panels PART 1 - GENERAL 1.1

More information

SECTION 07400 STANDING SEAM METAL ROOF

SECTION 07400 STANDING SEAM METAL ROOF SECTION 07400 STANDING SEAM METAL ROOF PART 1 - GENERAL 1.01 SECTION INCLUDES A. Work described in this section includes pre-formed standing seam metal roofing system complete with clips, perimeter and

More information

1. Section 074213.23 "Composite Wall Panel System"

1. Section 074213.23 Composite Wall Panel System SECTION 074113.16 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system

More information

SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here) SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2

More information

JANUARY, 2016 TR-7100 Windows (Fixed) 1 EC 97909-071 085113 ALUMINUM WINDOWS Guide Specs

JANUARY, 2016 TR-7100 Windows (Fixed) 1 EC 97909-071 085113 ALUMINUM WINDOWS Guide Specs JANUARY, 2016 TR-7100 Windows (Fixed) 1 EC 97909-071 085113 ALUMINUM WINDOWS Guide Specs SECTION 085113 ALUMINUM WINDOWS This suggested guide specification has been developed using the current edition

More information

Preformed Metal Roofing and Siding

Preformed Metal Roofing and Siding Page -1-1. GENERAL 1.1. Description This specification along with the drawings covers the furnishing of all material, products, equipment, accessories, tools, services, transportation, labor and supervision

More information

238T Standing Seam Metal Roof System (SSMRS)

238T Standing Seam Metal Roof System (SSMRS) 238T Standing Seam Metal Roof System (SSMRS) Text in red are instructions to the specifier and should be deleted. Text in blue are choices that need to be made, with those not selected, deleted. McElroy

More information

SECTION 07 95 00 EXPANSION CONTROL

SECTION 07 95 00 EXPANSION CONTROL SECTION 07 95 00 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

SECTION 07 41 13.16 - STANDING-SEAM METAL ROOF PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION 07 41 13.16 - STANDING-SEAM METAL ROOF PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS SECTION 07 41 13.16 - STANDING-SEAM METAL ROOF PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

ARCHITECTURAL METAL WALL AND ROOF SYSTEMS. 07 40 00 /CEN BuyLine 9165

ARCHITECTURAL METAL WALL AND ROOF SYSTEMS. 07 40 00 /CEN BuyLine 9165 ARCHITECTURAL METAL WALL AND ROOF SYSTEMS 07 40 00 /CEN BuyLine 9165 CENTRIA FORM MEETS FUNCTION CENTRIA is the world s leading innovator and manufacturer of high-performance building enclosure systems,

More information

CENTRIA Formawall Dimension Series Insulated Core Metal Wall Panel System with Integrated Components

CENTRIA Formawall Dimension Series Insulated Core Metal Wall Panel System with Integrated Components CENTRIA Formawall Dimension Series Insulated Core Metal Wall Panel System with Integrated Components CENTRIA Formawall pressure-equalized insulated core metal wall panel system is designed as a complete

More information

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS ROOFING APPLICATION STANDARD (RAS) No. 133 STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS 1. Scope 1.1 This application standard has been developed to provide consistent information for the

More information

SECTION 07411 PREFORMED METAL ROOF PANELS

SECTION 07411 PREFORMED METAL ROOF PANELS SECTION 07411 PREFORMED METAL ROOF PANELS PART 1 GENERAL 1.01 SECTION INCLUDES A. Roofing system of preformed aluminum panels. B. Fastening system. C. Underlayment. D. Accessories and miscellaneous components.

More information

EDD-401. Stationary Louver Dual Drainable Blade. Application and Design. Standard Construction

EDD-401. Stationary Louver Dual Drainable Blade. Application and Design. Standard Construction Application and Design is a weather louver designed to protect air intake and exhaust openings in building exterior walls. Design incorporates a drainable head member and stationary horizontal blades to

More information

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system. SECTION 075416 - PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system. 1.2 PERFORMANCE REQUIREMENTS A. Solar Reflectance

More information

SECTION 08 5656 GUARDA SECURITY WINDOW SCREENS

SECTION 08 5656 GUARDA SECURITY WINDOW SCREENS Page 1 of 5 SECTION 08 5656 GUARDA SECURITY WINDOW SCREENS Guarda Security Window Screens in this specification are appropriate for use in windows, storefronts, curtain walls, vents, and any other applications

More information

City of San Diego, CWP Guidelines

City of San Diego, CWP Guidelines PART 1 -- GENERAL SECTION 08520-1.1 WORK OF THIS SECTION City of San Diego, CWP Guidelines A. The WORK of this Section includes providing aluminum windows with frames, bracing, glazing attachments, screens,

More information

VA25014B0516 VA CINCINNATI PROJECT NO. 539-328 INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION 09 29 00 GYPSUM BOARD

VA25014B0516 VA CINCINNATI PROJECT NO. 539-328 INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION 09 29 00 GYPSUM BOARD SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board, vapor retarder and air and moisture barrrier. 1.2 RELATED WORK A. Installation

More information

SECTION 08560 SERIES 1500 VINYL PATIO DOORS

SECTION 08560 SERIES 1500 VINYL PATIO DOORS SERIES 1500 VINYL PATIO DOORS PART 1 GENERAL 1.1 SECTION INCLUDES A. Patio Doors 1.2 RELATED SECTIONS A. Section 05450: Cold Formed Metal Framing. B. Section 06100: Rough Carpentry. C. Section 06200: Finish

More information

COLORADO MODEL. 35 x 65 SPECIFICATIONS

COLORADO MODEL. 35 x 65 SPECIFICATIONS COLORADO MODEL 35 x 65 SPECIFICATIONS Dimensions: Roof Dimensions 35-0 x 65-0 Column Dimensions (center to center) 31-0 x 30-6 Minimum Clearance 14-0 Roof Height @ Peak ±18-8 Curved Roof ±42-6 radius Square

More information

SECTION 07 4243 METAL COMPOSITE MATERIAL WALL PANELS

SECTION 07 4243 METAL COMPOSITE MATERIAL WALL PANELS Use this section when specifying C.R. Laurence DWS Series 200 Deluxe Wet Seal for Aluminum-faced, stainless steel, copper, or titanium Composite Material Wall Panel System. This Specification Section is

More information

Sapa: SECTION 05520 ARCHITECTURAL ALUMINUM HANDRAILS AND RAILINGS

Sapa: SECTION 05520 ARCHITECTURAL ALUMINUM HANDRAILS AND RAILINGS PART 1 GENERAL Sapa: SECTION 05520 ARCHITECTURAL ALUMINUM HANDRAILS AND RAILINGS 1.1 SECTION INCLUDES A. Aluminum and Glass Handrails B. Aluminum Railings 1.2 RELATED SECTIONS A. Section 05700 - Ornamental

More information

ARCHITECTURAL METAL WALL AND ROOF SYSTEMS. 07 40 00 /CEN BuyLine 9165

ARCHITECTURAL METAL WALL AND ROOF SYSTEMS. 07 40 00 /CEN BuyLine 9165 ARCHITECTURAL METAL WALL AND ROOF SYSTEMS 07 0 00 /CEN BuyLine 965 Distinctively INNOVATIVE. Distinctively SUSTAINABLE. Distinctively INSTALLED. CENTRIA is the place where owner and architect visions are

More information

- - - - Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

- - - - Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner The Kelly Klosure pre-framed modular panel has 4 components that are factory finished to create an easy and versatile bolt-together system in the field. Steel Panel Frame Exterior Steel Sheeting Optional

More information

SECTION 074100 STANDING SEAM ROOF PANELS

SECTION 074100 STANDING SEAM ROOF PANELS SECTION 074100 STANDING SEAM ROOF PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

DENVER MODEL 30 X 30 SPECIFICATIONS

DENVER MODEL 30 X 30 SPECIFICATIONS DENVER MODEL 30 X 30 SPECIFICATIONS Dimensions: Roof Dimensions 30-0 x 30-0 (4) Columns (Center to Center) 25-6½ x 25-6½ Minimum Clearance 8-0 Roof Height @ Peak Dependent on Col. Ht. Hip Roof 4:12 pitch

More information

Window Installation Instructions

Window Installation Instructions Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for

More information

SECTION 05 7360 ALUMINUM HANDRAIL AND RAILING SYSTEMS WITH DECORATIVE METAL PANEL INFILLS

SECTION 05 7360 ALUMINUM HANDRAIL AND RAILING SYSTEMS WITH DECORATIVE METAL PANEL INFILLS 1 SECTION 05 7360 ALUMINUM HANDRAIL AND RAILING SYSTEMS WITH DECORATIVE METAL PANEL INFILLS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and

More information

CHAPTER 7: Building Systems ROOFING SYSTEMS

CHAPTER 7: Building Systems ROOFING SYSTEMS ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen

More information

ATLANTA MODEL SPECIFICATIONS

ATLANTA MODEL SPECIFICATIONS ATLANTA MODEL 50 SPECIFICATIONS Dimensions: Roof Dimensions (point to point) 50-0 Column Dimensions (out to out of columns) 44-0 Eave Height 8-0 Roof Height @ Peak ±21-8⅞ Hip Roof 6:12 pitch Square Feet

More information

Designer Series. Technical/Product Information

Designer Series. Technical/Product Information Designer Series Technical/Product Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE WALL SYSTEM. MBCI DETAILS MUST BE FOLLOWED AS A MINIMUM TO INSURE APPROPRIATE

More information

SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word

More information

GUIDE SPECIFICATION. Manufacturer: DECRA Roofing Systems, Inc.

GUIDE SPECIFICATION. Manufacturer: DECRA Roofing Systems, Inc. GUIDE SPECIFICATION Manufacturer: DECRA Roofing Systems A Fletcher Building Company 1230 Railroad Street Corona, CA 92882 951-272-8180 phone 951-272-4476 facsimile www.decra.com SECTION 07314 [07 31 14]

More information

Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.

Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work. Installation Guide Before you begin, take the time to read this entire guide to clearly understand the requirements and steps to follow for proper installation. Warning Do not install defective material.

More information

Rouse Life Sciences Roof Repair or Replacement 07 61 13 SECTION 07 61 13

Rouse Life Sciences Roof Repair or Replacement 07 61 13 SECTION 07 61 13 1. PART 1 - GENERAL 1.1 DESCRIPTION OF WORK SECTION 07 61 13 STANDING SEAM METAL ROOFING 1. This Section covers the pre-finished, pre-fabricated Architectural standing seam roof system. All metal trim,

More information

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 8 DOORS AND WINDOWS 08 50 00 WINDOWS

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 8 DOORS AND WINDOWS 08 50 00 WINDOWS SECTION INCLUDES Metal Windows Vinyl/Aluminum Clad Wood Windows Solid Fiberglass and Vinyl Windows Wood Windows (Historic Preservation only) RELATED SECTIONS 02 83 00 Lead Paint Remediation 06 10 00 Rough

More information

TEST REPORT. Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana

TEST REPORT. Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana Architectural Testing TEST REPORT Report No.: D0162.02-201-44 Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana PRODUCT TYPE: Pressure Equalized Rainscreen SERIES/MODEL: 4 mm Composite

More information

Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide

Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer /Installers.. 1 Fastener Placement and Selection.2-3

More information

GUIDE SPECIFICATION. Manufacturer: DECRA Roofing Systems, Inc.

GUIDE SPECIFICATION. Manufacturer: DECRA Roofing Systems, Inc. GUIDE SPECIFICATION Manufacturer: DECRA Roofing Systems A Fletcher Building Company 1230 Railroad Street Corona, CA 92882 951-272-8180 phone 951-272-4476 facsimile www.decra.com SECTION 07313 [07 31 13]

More information

Miami-Dade Qualified Drainable Blade Louvered Penthouse

Miami-Dade Qualified Drainable Blade Louvered Penthouse Application and Design is a gravity intake or exhaust louvered penthouse. Model incorporates high performance horizontal drainable style blades. Meets the performance requirements established by the Florida

More information

INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT.

INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT. INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT. awipanels.com From freezing, sub-zero temperatures to Contents dry heat or high humidity, Mother Nature continually tests the limits of building envelopes. That's

More information

Fire Resistant Aluminum Composite Material Building Panels (FR) Section 07410

Fire Resistant Aluminum Composite Material Building Panels (FR) Section 07410 Fire Resistant Aluminum Composite Material Building Panels (FR) Section 07410 Part 1 GENERAL 1.01 Summary A. Section Includes 1. The extent of panel system work is indicated on the drawings and in these

More information

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association Air-Conditioning, Heating, and Refrigeration Institute Sheet Metal and Air-Conditioning Contractors National Association GUIDELINE B-1997 ACKNOWLEDGEMENT These guidelines for Roof Mounted Outdoor Air-

More information

Standing Seam Roof Systems

Standing Seam Roof Systems Standing Seam Roof Systems REAL PEOPLE. REAL PRODUCTS. REAL SOLUTIONS. www.a-s.com Building Benefits You Can Expect From A&S Materials Standing Seam roof panels weigh a relatively modest 11/2 pounds per

More information

INSTRUCTIONS FOR COORDINATION SECTION 06651 SOLID SURFACE FABRICATIONS

INSTRUCTIONS FOR COORDINATION SECTION 06651 SOLID SURFACE FABRICATIONS INSTRUCTIONS FOR COORDINATION SECTION 06651 SOLID SURFACE FABRICATIONS 1. Paragraph 1.02 Provide solid surface countertops at sinks locations. Provide solid surface window sills at drywall framing walls.

More information

Ver. 2. Guide to. Inspecting Residential Brick Veneer

Ver. 2. Guide to. Inspecting Residential Brick Veneer Ver. 2 Guide to Inspecting Residential Brick Veneer 1. A guide created by industry professionals. The knowledgeable staff at MASONPRO together with technical support from the Masonry Institute of Michigan

More information

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003) NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:

More information

A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, 2012. All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA

A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, 2012. All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA Page 1 of 10, Addendum No. 3 Temporary Garage Structure City of Chelsea, MA November 5, 2012 CBI Job No.: 12055-A A D D E N D U M # 3 DATE: November 5, 2012 TO: FROM: PROJECT: All Bidders Jenne dos Santos,

More information

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers.. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer /Installers.. 1 Fastener Placement and Selection.2-3

More information

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150 THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150 SECTION ONE A. Objective The objective of this guide is to provide Owners and General Contractors/Construction

More information

Sun Windows General Information Sun New Construction Window Installation Instructions

Sun Windows General Information Sun New Construction Window Installation Instructions Sun Windows General Information Section 1 G F H H H A. Apply Weather Resistive Barrier B. Apply Sill Flashing Tape C. Place Waterproof Sill Shims D. Caulk Back of Nail Fin Sides & Top, Set Window, Fasten

More information

Display hidden notes to specifier. (Don't know how? Click Here) A. Advanced Upcoiling Security Grilles, power operated.

Display hidden notes to specifier. (Don't know how? Click Here) A. Advanced Upcoiling Security Grilles, power operated. SECTION 08333 ADVANCED UPCOILING SECURITY GRILLE MODEL 600 ADV Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Advanced Upcoiling Security Grilles,

More information

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for Vinyl windows with an integral nailing fin. While the use of these installation instructions

More information

PROPOSED SPECIFICATION FOR ALUCOBOND PLUS Aluminium Composite Panel Cladding System Fixed Watertight Cassette Panel System - 4mm thick

PROPOSED SPECIFICATION FOR ALUCOBOND PLUS Aluminium Composite Panel Cladding System Fixed Watertight Cassette Panel System - 4mm thick 1. SCOPE OF WORK The scope of work includes the design, supply fabrication and installation of Alucobond PLUS aluminium composite panel cladding, complete with all necessary sub-structures, anchors, hardware

More information

PERFORMANCE TEST REPORT. Rendered to: BAMCO INC. PRODUCT TYPE: ACM Wall Panel Systems

PERFORMANCE TEST REPORT. Rendered to: BAMCO INC. PRODUCT TYPE: ACM Wall Panel Systems PERFORMANCE TEST REPORT Rendered to: BAMCO INC. PRODUCT TYPE: ACM Wall Panel Systems Summary of Results Title Test Specimen #1 Test Specimen #2 Air Infiltration

More information

SECTION 07410 METAL ROOF SYSTEM

SECTION 07410 METAL ROOF SYSTEM SECTION 07410 METAL ROOF SYSTEM PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and General Provisions of Contract, including General Conditions and other Division 1 Specification Sections, apply to

More information

Springlok Flashing System

Springlok Flashing System Springlok Flashing System Why Fry Reglet? Fry Reglet s comprehensive selection of moisture prevention products offer the ultimate in protection from the elements. Available nationwide in a variety of materials

More information

Tundra Series Windows January 2016

Tundra Series Windows January 2016 Tundra Series Windows January 2016 New Construction Installation Instructions Nail Fin, J-Fin and Brickmold Aplications product. ATTENTION! Read and understand all installation instructions before installing

More information

GreenGuard Housewrap Installation Guide

GreenGuard Housewrap Installation Guide 000768PACBPHW_Flashing Bro 5/23/03 2:52 PM Page 1 For the most current product information, go to www.green-guard.com. Pactiv Building Products believes the information and recommendations herein to be

More information

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Architectural. Roofing. Basis of Design

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Architectural. Roofing. Basis of Design Basis of Design This section applies to roofing membranes, flashing and accessories. Design Criteria Adhere to the standards and details of the latest editions of the National Contractors Association (NRCA)

More information

INSTALLATION OF A BAY WINDOW

INSTALLATION OF A BAY WINDOW INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening

More information

SECTION 07540 - THERMOPLASTIC MEMBRANE ROOFING

SECTION 07540 - THERMOPLASTIC MEMBRANE ROOFING SECTION 07540 - THERMOPLASTIC MEMBRANE ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

ROOF FLASHING SPRINGLOK FLASHING SYSTEM FEATURES & BENEFITS PRODUCT DESCRIPTION

ROOF FLASHING SPRINGLOK FLASHING SYSTEM FEATURES & BENEFITS PRODUCT DESCRIPTION SPRINGLOK SYSTEM PRODUCT DESCRIPTION FEATURES & BENEFITS Fry Reglet offers five flashing systems, each tailored for a particular type of substrate so you can get exactly what you need. SM Surface mounted

More information

GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER

GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER CHAPTER 25 GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER User note: Code change proposals to this chapter will be considered by the IBC Structural Code Development Committee during the 2016 (Group B)

More information

AAMA 2400-10. Standard Practice for Installation of Windows with a Mounting Flange in Open Stud Frame Construction for Low Wind/Water Exposure

AAMA 2400-10. Standard Practice for Installation of Windows with a Mounting Flange in Open Stud Frame Construction for Low Wind/Water Exposure A M E R I C A N A R C H I T E C T U R A L AAMA 2400-10 Standard Practice for Installation of Windows with a Mounting Flange in Open Stud Frame Construction for Low Wind/Water Exposure M A N U F A C T U

More information

DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS

DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the contract, including general and supplementary conditions and other Division 1

More information

SECTION 05 42 16 COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex

SECTION 05 42 16 COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex (Specifier Note: The purpose of this guide specification is to assist the specifier in correctly specifying cold-formed metal deck framing products and execution. The specifier needs to edit the guide

More information

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES ROOFING APPLICATION STANDARD (RAS) No. 117 STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES Scope 1.1.

More information

Asphalt Shingle Application Requirements

Asphalt Shingle Application Requirements Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt

More information

2. Division 05 Structural Steel Framing for steel framework requirements

2. Division 05 Structural Steel Framing for steel framework requirements SECTION 131200 - CLIMBING WALLS PART 1 GENERAL 1.1 SUMMARY A. This section includes the following: 1. GFRC Rock Realistic Climbing Wall System B. Related Sections 1. Division 04 Unit Masonry 2. Division

More information

STANDING SEAM SHEET METAL ROOFING

STANDING SEAM SHEET METAL ROOFING STANDING SEAM SHEET METAL ROOFING GENERAL INFORMATION 1.1 For all standing seam metal roofing work consult Columbia University Facilities Exteriors and Historic Preservation group. 1.2 Fabricator is responsible

More information

Avoiding Air Barrier Pitfalls

Avoiding Air Barrier Pitfalls Avoiding Air Barrier Pitfalls Design & Durability November 2013 Air barriers, when correctly installed, help buildings achieve high levels of energy efficiency by decreasing heat loss. For example, great

More information

SECTION 08 53 13 VINYL WINDOWS. A. The General Conditions, Supplementary Conditions, and Division 01 - Requirements apply.

SECTION 08 53 13 VINYL WINDOWS. A. The General Conditions, Supplementary Conditions, and Division 01 - Requirements apply. SECTION 08 53 13 VINYL WINDOWS PART 1 - GENERAL 1.1 CONDITIONS AND REQUIREMENTS A. The General Conditions, Supplementary Conditions, and Division 01 - Requirements apply. 1.2 SECTION INCLUDES A. Double

More information

CLEAR-DIVISIONS CENTERFOLD

CLEAR-DIVISIONS CENTERFOLD CLEAR-DIVISIONS CENTERFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS CENTERFOLD moveable The yellow highlighted areas in

More information

MOCK-UP TEST REPORT. Rendered to: TUBELITE, INC. PROJECT: 200 Series Curtain Wall Mock-Up

MOCK-UP TEST REPORT. Rendered to: TUBELITE, INC. PROJECT: 200 Series Curtain Wall Mock-Up MOCK-UP TEST REPORT Rendered to: TUBELITE, INC. PROJECT: 200 Series Curtain Wall Mock-Up Report No: 85616.01-120-32 Test Completion Date: 01/15/09 Report Date: 02/11/09 Record Retention End Date: 01/15/13

More information

SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION

SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION As of October 1, 2007, this mitigation form must be submitted as part of the roofing permit application package. Secondary water barrier (if applicable)

More information

CB-100 CB-150 CS-100 SL-100 SL-150 SLZ-1000

CB-100 CB-150 CS-100 SL-100 SL-150 SLZ-1000 CB-100 CB-150 CS-100 SL-100 SL-150 SLZ-1000 Details and Installation Guide October 2013 All information, descriptions and dimensions in this manual are current at the time of printing. As always, Custom-Bilt

More information

RACQUETBALL, HANDBALL OR SQUASH COURTS AND GYMNASIUM WALL SURFACES

RACQUETBALL, HANDBALL OR SQUASH COURTS AND GYMNASIUM WALL SURFACES 1807 Elmwood Avenue, Suite 275 Buffalo, New York 14207 (800) 543-5155 RACQUETBALL, HANDBALL OR SQUASH COURTS AND GYMNASIUM WALL SURFACES Fiberesin Wall System Provide materials and labor to complete courts

More information

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs. Skylight Installation Instructions This document provides instruction and guidelines for installation of both curb mount (CM) and self flashing (SF) unit skylights on flat, pitched (> or equal to 3/12

More information