SECTION METAL COMPOSITE MATERIAL WALL PANELS
|
|
|
- June Lynch
- 9 years ago
- Views:
Transcription
1 Use this section when specifying C.R. Laurence DWS Series 200 Deluxe Wet Seal for Aluminum-faced, stainless steel, copper, or titanium Composite Material Wall Panel System. This Specification Section is a manufacturer specific product Specification using the proprietary method of specifying applicable to project specifications and master guide specifications. Optional text is indicated by [ ]; delete optional text in final copy of Specification Section. This Section includes interior and exterior wall panels formed using Alpolic aluminum-faced composite material (ACM) or other metal composite material (MCM) face metal is available in aluminum, stainless steel, copper, or titanium. PART 1 GENERAL 1.01 SECTION INCLUDES A. Exterior cladding consisting of formed aluminum-faced composite material (ACM) or other metal composite material (MCM) sheet, secondary supports, and anchors to structure, attached to solid backup. MCM sheet face metal B. Matching flashing and trim RELATED REQUIREMENTS A. Section Cold Framed Metal Framing: Panel support framing. B. Section Weather Barriers: Weather barrier behind rainscreen wall system. C. Section Sheet Metal Flashing and Trim: Metal flashing components integrated with this wall system. D. Section Joint Sealers REFERENCE STANDARDS A. ASTM A Standard Specification for Stainless Steel Bars and Shapes; B. ASTM A 653/A 653M - Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process; C. ASTM A Standard Specification for Annealed or Cold-Worked Austenitic Stainless Steel Sheet, Strip, Plate, and Flat Bar; D. ASTM A 792/A 792M - Standard Specification for Steel Sheet, 55% Aluminum-Zinc Alloy- Coated by the Hot-Dip Process; 2006a. E. ASTM B Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate; F. ASTM B Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes; G. ASTM D Standard Test Method for Specular Gloss; 1989 (Reapproved 1999). H. ASTM D Standard Test Method for Climbing Drum Peel for Adhesives; 1998 (Reapproved 2004). I. ASTM D Standard Test Method for Determining Ignition Temperature of Plastics; 1996 (Reapproved 2001) / CRL
2 J. ASTM D Standard Practice for Calculation of Color Differences from Instrumentally Measured Color Coordinates; K. ASTM D Standard Test Method for Coating Flexibility of Prepainted Sheet; 1983 (Reapproved 2002). L. ASTM D Standard Test Methods for Evaluating the Degree of Chalking of Exterior Paint Films; M. ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building Materials; Specifier's note: Article below includes submittal of relevant data to be furnished by Contractor before, during and after construction. Coordinate this Article with Architect's and Contractor's duties and responsibilities in Conditions of the Contract and Division 1 Submittal Procedures Section SUBMITTALS A. Wall System Manufacturer Qualifications. B. Product Data: ACM [MCM] sheet and Wall Panel manufacturer's data sheets on each product to be used, including thickness, physical characteristics, and finish, and: 1. Finish manufacturer's data sheet showing physical and performance characteristics. 2. Storage and handling requirements and recommendations. 3. Fabrication instructions and recommendations. 4. Specimen warranty for finish, as specified herein. C. Shop Drawings: Show layout and elevations, dimensions and thickness of panels, ACM [MCM] sheet finishes and textures, connections, details and location of joints, sealants and gaskets, method of anchorage, number of anchors, supports, reinforcement, trim, flashings, and accessories. 1. Indicate panel numbering system. 2. Differentiate between shop and field fabrication. 3. Indicate substrates and adjacent work with which the wall system must be coordinated. D. Samples: Submit selection and verification samples of ACM [MCM] wall panel, inch ( mm) by inch ( mm) in size illustrating finish color, sheen, and texture. 1. Selection samples: Manufacturer's color charts or chips illustrating full range of colors, finishes and textures available for ACM [MCM] with factory-applied finishes. 2. Verification samples: a. Structural: 24 inch by 24 inch sample ACM [MCM] wall panel assembly, including intersection of 4 wall panels, in thickness specified, including Z-clips, stiffeners, substrate supports, and sealant for assembly approval. b. Include separate samples with factory applied finish on 6 inch by 6 inch ACM [MCM], of each color and finish selected for project. E. Installer s Qualifications: Include a minimum of three (3) projects with similar types of exterior ACM [MCM] wall panels, with facility contact information. F. Certificate: Certify that the work results of this section meet or exceed specified requirements. G. Manufacturer's installation instructions / CRL
3 H. Manufacturer's Field Reports: Provide within 48 hours of field review. State what was observed and what changes, if any, were requested or required. I. Maintenance Data: Care of finishes and warranty requirements. J. Executed Warranty: Submit warranty and ensure that forms have been completed in CRL's name and registered with manufacturer. Specifier's note: Article below to include qualifications, prerequesites, standards, limitations, and criteria to establish the requirements for the level of quality for products and workmanship for the work of this section. Coordinate Article with Division 1 Quality Assurance Section QUALITY ASSURANCE A. Field Measurements: Verify actual dimensions by field measurement before fabrication; show recorded measurements on shop drawings. B. Wall System Manufacturer Qualifications: Company specializing in manufacturing products specified in this section. 1. Approved by MCM sheet manufacturer. C. Installer Qualifications: Experienced in performing work of the type specified in this section. 1. With minimum 3 years of documented experience in installation of ACM [MCM] wall panel system similar to the work of this section. 2. Approved by wall system manufacturer. D. Design Engineer's Qualifications: When required by building authority having jurisdiction, Design structural supports and anchorages under direct supervision of a Structural Engineer experienced in design of this type of Work and licensed in [insert job specific state, or location]. E. Testing Agency Qualifications: Independent agency experienced in testing assemblies of the type required for this project and having the necessary facilities for full-size mock-up testing of the type specified. Specifier's note: Retain paragraph below if mock-up assemblies; erected either on-site, or off-site, are required. Mock-ups can be used to establish standards of quality for workmanship, review of construction sequence/operation, and coordination of work of related sections. Coordinate with Division 1 Quality Control Section; Mock-up requirements. F. Mock-Up: Provide a mock-up for evaluation of fabrication workmanship. 1. Locate on project site at an off-ste location]. 2. Provide panels finished as specified. 3. Mock-up may remain as part of the Work DELIVERY, STORAGE, AND HANDLING A. Deliver products in manufacturer's original, unopened, undamaged containers with identification labels intact. 1. Protect finishes by applying heavy duty removable plastic film during production. 2. Package for protection against transportation damage. 3. Provide markings to identify components consistently with drawings / CRL
4 4. Exercise care in unloading, storing and installing panels to prevent bending, warping, twisting and surface damage. B. Store products protected from exposure to harmful weather conditions and at temperature conditions recommended by manufacturer WARRANTY A. Wall System Warranty: Provide written warranty by manufacturer, agreeing to correct defects in manufacturing within a 5 [10] [20] year period after Date of Substantial Completion. B. ACM [MCM] Sheet Manufacturer s Finish Warranty: Provide manufacturer's written warranty stating that the finish will perform as follows for minimum of years: 1. Chalking: No more than that represented by a No.8 rating based on ASTM D Color Retention: No fading or color change in excess of 5 Hunter color difference units, calculated in accordance with ASTM D Gloss Retention: Minimum of 30 percent gloss retention, when tested in accordance with ASTM D 523. PART 2 PRODUCTS 2.01 MANUFACTURERS A. Metal Composite Material Sheet Manufacturers: 1. ALPOLIC-Mitsubishi Chemical FP America, Inc; 401 Volvo Parkway, Chesapeake, VA 23320; Tel: (800) ; Fax: (757) ; [email protected]: 2. Substitutions: See Section Product Requirements. B. Wall Panel System Manufacturers: 1. C.R. Laurence Co,, Inc., P.O. Box 58923, Los Angeles, CA ; Tel: (800) or (323) Ext. 7770; Fax: (866) or (323) ; [email protected]. 2. Substitutions: No substitutions are permitted MATERIALS A. Aluminum-faced Composite Material (ACM) [Metal Composite Material (MCM)] Sheet: Two sheets of aluminum [stainless steel] [copper] [titanium with stainless steel backer sheet] sandwiching a solid core of extruded [fire resistive Alpolic/fr] thermoplastic material formed in a continuous process with no glues or adhesives between dissimilar materials; core material free of voids and spaces; no foamed insulation material content. 1. Overall Sheet Thickness: 4 mm [ 3mm thickness available upon request]. 2. Face Sheet: Aluminum alloy 3105 H14, inches (0.50 mm), minimum [Titanium 0.3 mm and 0.3 mm stainless steel backer sheet]. 3. Panel size: As indicated on Drawings; 5 ft by 16 ft - 4 inches maximum panel size. 4. Bond strength: 1500 psi (10.3 MPa) minimum when tested in accordance with ASTM C Peel Strength: No adhesive failure of the bond between the core and the skin nor cohesive failure of the core itself below 22.4 inch-pound/inch (100 N-mm/mm) with no degradation in bond performance, when tested in accordance with ASTM D 1781, simulating resistance to panel delamination, after 8 hours of submersion in boiling water and after 21 days of immersion in water at 70 degrees F (21 degrees C). 6. Fire performance: Flame spread; 0, maximum; smoke developed;10 maximum; when tested in accordance with ASTM E 84. [Fire resistive Alpolic/fr core has higher flash point and ignition temperature than standard core, and has been tested to UBC 26-9 Intermediate Scale Multi Story Apparatus Test - Passed (4 and 6 mm thickness), and UBC / CRL
5 26-3 Room Corner Test - Passed (4 mm thickness.] 7. Surface flammability (Modified ASTM E108): Passed. 8. Factory Finish: One coat fluoropolymer resin coating, approved by the coating manufacturer for the length of warranty specified for the project, and applied by coil manufacturing facility that specializes in coil applied finishes. Meets or exceeds values expressed in AAMA 2605 for coil coatings. a. Basis of Design: fluoropolymer resin coating as manufactured by. b. Coating Flexibility: Pass ASTM D 4145 minimum 1T-bend, at time of manufacturing. c. Long-Term Performance: Not less than that specified under WARRANTY in PART Color/Texture: As selected from manufacturer's standard color selections below. Custom colors available upon request. a. Aluminum Series: 1) DWS200CBW Composite - Bone White 2) DWS200CCM Composite - Champagne Metallic 3) DWS200CMP Composite - Mica Platinum 4) DWS200CSM Composite - Silver Metallic 5) Custom colors available upon request] b. Stone Series: 1) DWS200CBG Composite - Black Granite 2) DWS200CWM Composite - White Marble Exotic c. Metals Series: 1) DWS200CCP Composite - Copper 2) DWS200CBS Composite - Stainless Steel 3) DWS200CT Composite - Titanium 10. ACM [MCM] sheet production tolerances: a. Width: plus or minus 0.04 inch in 3 feet (1mm in 1m). b. Length: plus or minus 0.04 inch in 3 feet (1mm in 1 m). c. Thickness (4 mm sheet): plus or minus inch (0.2 mm). d. Bow: Maximum 0.5% length or width. e. Squareness: Maximum 0.2 inch (5.1mm). f. Edges of sheet shall be square and trimmed with no displacement of aluminum sheets or protrusion of core material. B. Metal Framing Members: Include subgirts, extruded aluminum framing, mounting clips, base and sill angles and channels, hat-shaped and rigid channels, and furring channels required for complete installation. 1. Aluminum extrusions: ASTM B 221, 6063-T6 alloy, with mill finish. Z-clips, stiffeners and angles as recommended by manufacturer. 2. Provide material strength, dimensions, configuration as required to meet the applied loads applied and in compliance with applicable building code. 3. Sheet Steel Components: ASTM A 653/A 653M galvanized to G90/Z275 or zinc-iron alloycoated to A60/ZF180; or ASTM A 792/A 792M aluminum-zinc coated to AZ60/AZM Stainless Steel Sheet Components: ASTM A 480/A 480M. C. Anchors, Clips and Accessories: 1. Stainless steel complying with ASTM A 480/A480M, ASTM A 276 or ASTM A 666. D. Fasteners: 1. Exposed fasteners: Stainless steel; permitted only where absolutely unavoidable and subject to prior approval of the Architect [Owner]. 2. Screws: Self-drilling or self-tapping Type 410 stainless steel or zinc-alloy steel hex washer head, with EPDM or PVC washer under heads of fasteners bearing on weather side of metal wall panels. 3. Rivets: Aluminum blind rivets / CRL
6 4. Fasteners for Flashing and Trim: Blind fasteners of high-strength aluminum or stainless steel. 5. Tape: 3M VHB conformable tape, 1/2 inch wide by 1/16 inch thick closed cell acrylic foam carrier, conformable tape, 200 degree F long term temperature resistance, 300 degree F short term. Very good adhesion to painted surfaces and high solvent resistance. E. Joint Sealer: Silicone silicone sealant: CRL 95C, as approved by MCM sheet manufacturer WALL PANEL SYSTEM A. Wall Panel System: Metal panels, fasteners, and anchors designed to be supported by framing or other substrate provided by others; provide installed panel system capable of maintaining specified performance without defects, damage or failure. 1. When required by building authority having jurisdiction, provide structural design by or under a licensed Structural Engineer licensed in [insert job specific state, or location]. 2. Provide panel jointing and weatherseal using a "wet," sealant sealed system. 3. Anchor panels to supporting framing without exposed fasteners. B. Panels: One inch (2.5 mm) deep pans formed of metal composite material sheet by routing back edges of sheet, removing corners, and folding edges. 1. Panels are "V" cut using CNC routing machine. Holes for extruded aluminum framing are pre-drilled. 2. Holes for extruded aluminum framing are pre-drilled during fabrication. Drill machine is programmed using Mastercam X software. 3. Panels are bent using press brakes. 4. Curve forming is by plate roller. 5. Panels are reinforced with continuous extruded aluminum section, mechanically fastened. 6. Extruded aluminum framing is mechanically fastened to perimeter of panel using 3/16 inch dia. aluminum rivets spaced 10 inches on center. Holes are punched out on framing to match the holes on the panels. Extruded aluminum mounting clips are cut to 5 inch lengths with punched holes. 7. Stiffeners are attached to panels over 36 inches in length. 8. Reinforce corners with riveted aluminum angles. 9. Provide concealed attachment to supporting structure by adhering attachment members to back of panel; attachment members may also function as stiffeners. 10. Maintain maximum panel bow of 0.8 percent of panel dimension in width and length; provide stiffeners of sufficient size and strength to maintain panel flatness without showing local stresses or read-through on panel face. 11. Reinforce panels with aluminum stiffeners. Attach stiffeners to back face of panels with 3M VHB tape conformable foam tape. 12. Attach aluminum zee clips to back face of panels at each edge with 3/16 inch aluminum blind rivets. 13. Fabricate panels under controlled shop conditions. 14. Incorporate actual field measurements into fabrication Drawings. 15. Where final dimensions cannot be established by field measurement before commencement of manufacturing, make allowance for field adjustments without requiring field fabrication of panels. Field routing, bending forming of ACM [MCM] panels is not acceptable. 16. Fabricate as indicated on drawings and as recommended by ACM [MCM] sheet manufacturer. a. Make panel lines, breaks, curves and angles sharp and true. b. Keep plane surfaces free from warp or buckle. c. Keep panel surfaces free of scratches or marks caused during fabrication / CRL
7 d. Panels are packaged, and shipped with zee clips and stiffeners attached to panels / CRL
8 17. Provide joint details providing a watertight and structurally sound wall panel system that allows no uncontrolled water penetration on inside face of panel system. PART 3 EXECUTION 3.01 EXAMINATION A. Verify dimensions, tolerances, and interfaces with other work are acceptable for MCM panel installation. B. Verify substrate on-site to determine that conditions are acceptable for product installation in accordance with manufacturers written instructions. C. Verify subgirts have been installed perpendicular to panel length, securely fastened to substrates and shimmed and leveled to uniform plane. Space at intervals indicated. D. Notify in writing of conditions detrimental to proper and timely completion of work. Do not proceed with erection until unsatisfactory conditions have been corrected PREPARATION A. Protect adjacent work areas and finish surfaces from damage during installation INSTALLATION A. Do not install products that are defective, including warped, bowed, dented, and broken members, and members with damaged finishes. B. Comply with instructions and recommendations of MCM sheet manufacturer and wall system manufacturer, as well as with approved shop drawings. C. Install wall system securely allowing for necessary thermal and structural movement; comply with wall system manufacturer's instructions for installation of concealed fasteners. D. Do not rout, bend, or otherwise form panels in field unless required by wall system manufacturer and approved by the ; comply with MCM sheet manufacturer's instructions and recommendations for field forming. E. Separate dissimilar metals; use gasket fasteners, isolation shims, or isolation tape where needed to eliminate possibility of electrolytic action between metals. F. Where joints are designed for field applied sealant, seal joints completely with specified sealant. G. Install square, plumb, straight, and true, accurately fitted, with tight joints and intersections maintaining the following installation tolerances: 1. Variation From Plane or Location: 1/2 inch in 30 feet (10 mm in 10 m) of length and up to 3/4 inch in 300 feet (20 mm in 100 m), maximum. 2. Deviation of horizontal and vertical alignment of installed MCM panels: 0.25 inch in 20 feet (6.4 mm in 6.1 m), noncumulative. 3. Offset From True Alignment Between Two Adjacent Members Abutting End To End, In Line: 0.03 inch (0.75 mm), maximum. H. Replace damaged products FIELD QUALITY CONTROL A. Wall System Manufacturer's Field Services: Provide field services consisting of product use recommendations and periodic site visits for inspection of product installation in accordance with instructions / CRL
9 3.05 CLEANING A. Repair panels with minor damage such that repairs are not visible from a distance of 10 feet (3 m). B. Remove and replace panels that cannot be repaired. C. Remove protective film after installation of joint sealers, after cleaning of adjacent materials, and immediately prior to completion of work. D. Remove temporary coverings and protection of adjacent work areas. E. Clean installed products in accordance with manufacturer's instructions. END OF SECTION / CRL
SECTION 07 42 13 METAL WALL PANELS
Mitsubishi Plastics Composites America, Inc. 401 Volvo Parkway Chesapeake, VA 23320 Phone: (800) 422-7270 Fax: (757) 436-1896 E-mail: [email protected] www.alpolic-northamerica.com This MANU-SPEC utilizes
SECTION 07 61 13 STANDING SEAM METAL ROOFING
SECTION 07 61 13 STANDING SEAM METAL ROOFING PART 1 GENERAL 1.01 SCOPE OF WORK A. The Work shall include all labor, materials, equipment and supervision required to complete the work of the above referenced
SECTION 07410 PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK
SECTION 07410 PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK A. This section covers the pre-finished, pre-fabricated Architectural standing seam roof system. All metal trim,
PROPOSED SPECIFICATION FOR ALUCOBOND PLUS Aluminium Composite Panel Cladding System Fixed Watertight Cassette Panel System - 4mm thick
1. SCOPE OF WORK The scope of work includes the design, supply fabrication and installation of Alucobond PLUS aluminium composite panel cladding, complete with all necessary sub-structures, anchors, hardware
PART 1 GENERAL 1.1 SECTION INCLUDES
J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including
SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING
SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING PART ONE GENERAL DESCRIPTION This section includes pre-formed standing seam metal roofing and related flashings, closures, trim and accessories including,
Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023
Specifications Preformed Metal Wall and Roof Panels Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023 Section 07410 Preformed Metal Wall and Roof Panels Structural
INSTRUCTIONS FOR COORDINATION SECTION 06651 SOLID SURFACE FABRICATIONS
INSTRUCTIONS FOR COORDINATION SECTION 06651 SOLID SURFACE FABRICATIONS 1. Paragraph 1.02 Provide solid surface countertops at sinks locations. Provide solid surface window sills at drywall framing walls.
SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2
GUIDELINE SPECIFICATIONS
GUIDELINE SPECIFICATIONS GORDON SOFFIT-SHIELD - An Exterior Metal Soffit System DIVISION 05 5800 or DIVISION 07 7700 Note To Specifier: SOFFIT-SHIELD should be installed by tradesmen that are experienced
SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront
PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word
SECTION 05 7360 ALUMINUM HANDRAIL AND RAILING SYSTEMS WITH DECORATIVE METAL PANEL INFILLS
1 SECTION 05 7360 ALUMINUM HANDRAIL AND RAILING SYSTEMS WITH DECORATIVE METAL PANEL INFILLS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and
A. Double lock standing seam, single element, metal roof panels.
Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions SECTION 07 41 13 METAL ROOF PANELS Morin Metal Panels Double Lock Standing Seam Metal Roof Panels PART 1 - GENERAL 1.1
Window Installation Instructions
Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for
City of San Diego, CWP Guidelines
PART 1 -- GENERAL SECTION 08520-1.1 WORK OF THIS SECTION City of San Diego, CWP Guidelines A. The WORK of this Section includes providing aluminum windows with frames, bracing, glazing attachments, screens,
Holiday Inn Express & Suites Covington (Newton County) 1. Standing-seam metal roofing, custom fabricated.
PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Standing-seam metal roofing, custom fabricated. 1.2 SUBMITTALS A. Product Data: For each type of product indicated. B. Shop Drawings: Show installation
SECTION 07410 METAL ROOF & WALL PANELS
This document specifies Metal Roofing Systems prefinished factory formed metal roofing marketed as MRS System 2500 steel and aluminum roofing systems and includes MRS flashing and Trim. MRS finish is a
SECTION 07411 STANDING SEAM METAL ROOFING
PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following: 1. Standing-seam metal roof. 2. Metal gutters. 1.2 DEFINITIONS A. Metal Roof Panel Assembly: Metal roof panels, waterproofing membrane (underlayment),
SECTION 08 5656 GUARDA SECURITY WINDOW SCREENS
Page 1 of 5 SECTION 08 5656 GUARDA SECURITY WINDOW SCREENS Guarda Security Window Screens in this specification are appropriate for use in windows, storefronts, curtain walls, vents, and any other applications
Fire Resistant Aluminum Composite Material Building Panels (FR) Section 07410
Fire Resistant Aluminum Composite Material Building Panels (FR) Section 07410 Part 1 GENERAL 1.01 Summary A. Section Includes 1. The extent of panel system work is indicated on the drawings and in these
SPECIFICATION Aluminum Module Frames. Allowed anodization before fabrication for clear frames.
SPECIFICATION Allowed anodization before fabrication for clear frames. Page 2 of 9 1. SCOPE 1.1. This document provides general requirements for aluminum frames used in the assembly of photovoltaic modules.
EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS
EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS 1. SCOPE 1.1 This specification covers the type, physical properties and dimensions of Expanded Polystyrene Insulation Board intended for use
Preformed Metal Roofing and Siding
Page -1-1. GENERAL 1.1. Description This specification along with the drawings covers the furnishing of all material, products, equipment, accessories, tools, services, transportation, labor and supervision
JANUARY, 2016 TR-7100 Windows (Fixed) 1 EC 97909-071 085113 ALUMINUM WINDOWS Guide Specs
JANUARY, 2016 TR-7100 Windows (Fixed) 1 EC 97909-071 085113 ALUMINUM WINDOWS Guide Specs SECTION 085113 ALUMINUM WINDOWS This suggested guide specification has been developed using the current edition
Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood
Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood Section 07411 Metal Roof Panels Part 1 General 1.1 Summary A. This section includes the following: a. Factory-formed
ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING. January 24, 2014 06610-1
ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING January 24, 2014 06610-1 SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS MOLDED GRATING PART 1 - GENERAL 1.1 SCOPE OF WORK A. The CONTRACTOR
Display hidden notes to specifier. (Don't know how? Click Here) A. Advanced Upcoiling Security Grilles, power operated.
SECTION 08333 ADVANCED UPCOILING SECURITY GRILLE MODEL 600 ADV Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Advanced Upcoiling Security Grilles,
Sapa: SECTION 05520 ARCHITECTURAL ALUMINUM HANDRAILS AND RAILINGS
PART 1 GENERAL Sapa: SECTION 05520 ARCHITECTURAL ALUMINUM HANDRAILS AND RAILINGS 1.1 SECTION INCLUDES A. Aluminum and Glass Handrails B. Aluminum Railings 1.2 RELATED SECTIONS A. Section 05700 - Ornamental
SECTION 07400 STANDING SEAM METAL ROOF
SECTION 07400 STANDING SEAM METAL ROOF PART 1 - GENERAL 1.01 SECTION INCLUDES A. Work described in this section includes pre-formed standing seam metal roofing system complete with clips, perimeter and
238T Standing Seam Metal Roof System (SSMRS)
238T Standing Seam Metal Roof System (SSMRS) Text in red are instructions to the specifier and should be deleted. Text in blue are choices that need to be made, with those not selected, deleted. McElroy
1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.
SECTION 075416 - PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system. 1.2 PERFORMANCE REQUIREMENTS A. Solar Reflectance
CLEAR-DIVISIONS CENTERFOLD
CLEAR-DIVISIONS CENTERFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS CENTERFOLD moveable The yellow highlighted areas in
SCENIC VIEW SV 10 SECTION 08 87 13 SOLAR CONTROL FILMS
PART 1 GENERAL SCENIC VIEW SV 10 SECTION 08 87 13 SOLAR CONTROL FILMS 1.1 SUMMARY A. Optically clear dual reflective, neutral sputtered and aluminum metallized polyester film for solar control. 1.2 RELATED
MOCK-UP TEST REPORT. Rendered to: TUBELITE, INC. PROJECT: 200 Series Curtain Wall Mock-Up
MOCK-UP TEST REPORT Rendered to: TUBELITE, INC. PROJECT: 200 Series Curtain Wall Mock-Up Report No: 85616.01-120-32 Test Completion Date: 01/15/09 Report Date: 02/11/09 Record Retention End Date: 01/15/13
WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING
WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING IMPORTANT NOTICES AND INFORMATION Read these instructions in their entirety prior to installing windows. Any local building code requirements
RACQUETBALL, HANDBALL OR SQUASH COURTS AND GYMNASIUM WALL SURFACES
1807 Elmwood Avenue, Suite 275 Buffalo, New York 14207 (800) 543-5155 RACQUETBALL, HANDBALL OR SQUASH COURTS AND GYMNASIUM WALL SURFACES Fiberesin Wall System Provide materials and labor to complete courts
TEST REPORT. Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana
Architectural Testing TEST REPORT Report No.: D0162.02-201-44 Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana PRODUCT TYPE: Pressure Equalized Rainscreen SERIES/MODEL: 4 mm Composite
09/07/07 GLASSFIBER REINFORCED CEMENT (GRC) C. S. I. Spec 03500 Master Spec. 03 49 00 Page 1
C. S. I. Spec 03500 Page 1 PART 1 - GENERAL 1.01 SUMMARY:.01 Provide special glassfiber reinforced cement (GRC) shapes in accordance with the requirements of the contract documents..02 The installing contractor
Product Guide Specification
Stabilit America, Inc., dba Glasteel June 2005 285 Industrial Drive Moscow, Tennessee 38057 Toll Free (800) 238-5546 Phone (901) 877-3010 Fax (901) 877-1388 Web Site www.glasteel.com Product Guide Specification
Sun Windows General Information Sun New Construction Window Installation Instructions
Sun Windows General Information Section 1 G F H H H A. Apply Weather Resistive Barrier B. Apply Sill Flashing Tape C. Place Waterproof Sill Shims D. Caulk Back of Nail Fin Sides & Top, Set Window, Fasten
SECTION 08560 SERIES 1500 VINYL PATIO DOORS
SERIES 1500 VINYL PATIO DOORS PART 1 GENERAL 1.1 SECTION INCLUDES A. Patio Doors 1.2 RELATED SECTIONS A. Section 05450: Cold Formed Metal Framing. B. Section 06100: Rough Carpentry. C. Section 06200: Finish
SECTION 07 95 00 EXPANSION CONTROL
SECTION 07 95 00 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply
Clad Direct Glaze Window Installation Instructions
Clad Direct Glaze Window Installation Instructions Sill flashing and sealing: 2. An overview of the proper flashing sequence is shown in figure 1. Please read entire installation instructions carefully
FIRESTOPPING & SMOKE SEALS
SPECIFICATION SECTION 07 84 00 FIRESTOPPING & SMOKE SEALS 1 GENERAL 1.1 SECTION INCLUDES 1.1.1 Comply with Division 1, General Requirements and Documents referred to therein. 1.1.2 It is the intent of
PERFORMANCE TEST REPORT. Rendered to: BAMCO INC. PRODUCT TYPE: ACM Wall Panel Systems
PERFORMANCE TEST REPORT Rendered to: BAMCO INC. PRODUCT TYPE: ACM Wall Panel Systems Summary of Results Title Test Specimen #1 Test Specimen #2 Air Infiltration
ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES
ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES PART 1 - GENERAL 1.1 SCOPE OF WORK SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED SQUARE TUBE LADDER
SECTION 260536 - CABLE TRAYS. A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system.
SECTION 260536 - CABLE TRAYS PART 1 - GENERAL SECTION INCLUDES: A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system. B. Cable tray systems are defined to include, but
Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows
Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows americancraftsmanwindows.com Project Requirements: Read
DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS
DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the contract, including general and supplementary conditions and other Division 1
Tundra Series Windows January 2016
Tundra Series Windows January 2016 New Construction Installation Instructions Nail Fin, J-Fin and Brickmold Aplications product. ATTENTION! Read and understand all installation instructions before installing
ROXUL Board Insulation Section 07 21 13 Master Guide Specification (CAVITYROCK ) Page 1 April 2016
Master Guide Specification (CAVITYROCK ) Page 1 Click on the pilcrow in the MS Word Toolbar to toggle ROXUL GUIDE NOTES on and off. Delete this text before incorporating the section into a Project Manual.
A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, 2012. All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA
Page 1 of 10, Addendum No. 3 Temporary Garage Structure City of Chelsea, MA November 5, 2012 CBI Job No.: 12055-A A D D E N D U M # 3 DATE: November 5, 2012 TO: FROM: PROJECT: All Bidders Jenne dos Santos,
foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.
Skylight Installation Instructions This document provides instruction and guidelines for installation of both curb mount (CM) and self flashing (SF) unit skylights on flat, pitched (> or equal to 3/12
CLEAR-DIVISIONS VARIOFOLD
CLEAR-DIVISIONS VARIOFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS VARIOFOLD moveable The yellow highlighted areas in the
Basement Window Installation Guide Hopper and Sliding
Basement Window Installation Guide Hopper and Sliding americancraftsmanwindows.com Project Requirements: Installation must comply with all applicable building codes. Existing window frame, wall and weatherresistant
INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION FOR DOUBLE-HUNG VENT REPLACEMENT WINDOW
Vinyl Windows and Doors Manufactured by Pella Corporation INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION FOR DOUBLE-HUNG VENT REPLACEMENT WINDOW Lea las instrucciones en español en el reverso.
SECTION 05 42 16 COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex
(Specifier Note: The purpose of this guide specification is to assist the specifier in correctly specifying cold-formed metal deck framing products and execution. The specifier needs to edit the guide
NEW ELECTRICAL SUBSTATION Building 300 SECTION 07 53 23 ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK
ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within
Fiberglas, Exterior Wall Thermal Insulation
PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.
WATER LEAKAGE IN GLAZED CURTAIN WALL SYSTEMS:
WATER LEAKAGE IN GLAZED CURTAIN WALL SYSTEMS: BY WILLIAM D. SMITH Figure 1 Four Corporate Center, Franklin, TN. Architect: Little & Associates,Charlotte, NC. Gen. Contractor: Ray Bell Const. Co., Nashville,
K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11
K. D. FRAME ASSEMBLY FOR MASONRY WALLS...........................Ins 2 FRAME INSTALLATION DETAILS FOR MASONRY WALLS......................Ins 3 INSTALLING EXISTING MASONRY WALL ANCHORS IN FRAME..................Ins
Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.
Installation Guide Before you begin, take the time to read this entire guide to clearly understand the requirements and steps to follow for proper installation. Warning Do not install defective material.
Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing
Substrate, structural panel, bonded waterproofing The universal substrate for tiles Perfect covering No matter whether you work with mosaics or large format tiles, an absolutely level substrate with straight
Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin
Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin americancraftsmanwindows.com Project Requirements: Failure to follow these instructions may void product
INSTALLATION OF A BAY WINDOW
INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening
Standard Specification for Polyvinyl Chloride (PVC) and Other Organic Polymer-Coated Steel Chain-Link Fence Fabric 1
Designation: F 668 07 Standard Specification for Polyvinyl Chloride (PVC) and Other Organic Polymer-Coated Steel Chain-Link Fence Fabric 1 This standard is issued under the fixed designation F 668; the
C. Codes and References: Comply with the version year adopted by the Authority Having Jurisdiction.
SECTION 081216 - INTERIOR ALUMINUM DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
CLEAR-DIVISIONS APERTO
CLEAR-DIVISIONS Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS moveable glass wall system. The yellow highlighted areas in the
INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT.
INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT. awipanels.com From freezing, sub-zero temperatures to Contents dry heat or high humidity, Mother Nature continually tests the limits of building envelopes. That's
A. Work on this project shall consist of, but is not limited to, the following:
PART 1 - GENERAL CLEANING AND RESTORATION OF SECTION 05900-1 1.1 SUMMARY A. Work on this project shall consist of, but is not limited to, the following: 1. Clean and treat all exposed anodized architectural
AC-3200 ALUMINUM PLATE SYSTEM (DRY JOINT)
ALUMINUM PLATE SYSTEM (DRY JOINT) C D E G P J L A H M B Q F A B C D E F G H J K L M N P Q R HORIZONTAL JOINT DETAIL VERTICAL JOINT DETAIL COPING DETAIL (1) COPING DETAIL (2) COPING DETAIL (3) OUTSIDE CORNER
INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)
Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for Vinyl windows with an integral nailing fin. While the use of these installation instructions
2. Division 05 Structural Steel Framing for steel framework requirements
SECTION 131200 - CLIMBING WALLS PART 1 GENERAL 1.1 SUMMARY A. This section includes the following: 1. GFRC Rock Realistic Climbing Wall System B. Related Sections 1. Division 04 Unit Masonry 2. Division
Installation Guide for Andersen Architectural Clad Outswing Commercial Doors
Installation Guide for Andersen Architectural Clad Outswing Commercial Doors Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly, installation and maintenance
SECTION 11014 WINDOW WASHING SYSTEMS
SECTION 11014 WINDOW WASHING SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section includes, but is not limited to, design and furnishing portable davits, davit sleeves, dvit bases, four (4) removable outriggers,
VA25014B0516 VA CINCINNATI PROJECT NO. 539-328 INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION 09 29 00 GYPSUM BOARD
SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board, vapor retarder and air and moisture barrrier. 1.2 RELATED WORK A. Installation
GYPSUM AREA SEPARATION FIREWALLS GA-620-2011
GYPSUM AREA SEPARATION FIREWALLS GA-620-2011 GA-620-2011 Copyright 2011 Gypsum Association All rights reserved. Printed in U.S.A. Characteristics, properties, or performance of materials or systems herein
Introduction...COMB-2 Design Considerations and Examples...COMB-3
SECTION DIRECTORY General Information Introduction...COMB-2 Design Considerations and Examples...COMB-3 Combination Assembly Recommendations and Limitations Composite Configurations...COMB-4 Typical Sealant
PART E SPECIFICATIONS
PART E SPECIFICATIONS Page 1 of 5 PART E - SPECIFICATIONS GENERAL E1. APPLICABLE SPECIFICATIONS, STANDARD DETAILS AND DRAWINGS E1.1 The City of Winnipeg Works and Operations Division Standard Construction
ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES. July 1, 2008 Revision 2
ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES 1 PART 1 - GENERAL 1.0 GENERAL 1.1 REFERENCES: SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED FIBERGLASS
7. Installation. installation 7.1.1. CAST-IN WINDOW SYSTEM 7.1. INSTALLATION OF WINDOW MAIN FRAME
7. Installation Window involves the fixing of window frame at an earlier construction stage and subsequent of the window sashes. This is a highly workmanship dependent process. Only trained and approved
GigaCrete Specification PlasterMax
GigaCrete Inc. 6775 Speedway Blvd. Suite M105 Las Vegas, NV 89115 Ph (702) 643-6363 Fax (702) 643 1453 www.gigacrete.com GigaCrete Specification PlasterMax PlasterMax : Fire Rated Plaster for Direct Application
GreenGuard Housewrap Installation Guide
000768PACBPHW_Flashing Bro 5/23/03 2:52 PM Page 1 For the most current product information, go to www.green-guard.com. Pactiv Building Products believes the information and recommendations herein to be
07 21 19 Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
07 21 19 STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM 7819 Broadview Road Cleveland, OH 44131 800-522-4522 February, 2011 SPEC NOTE: This guide specification is intended for use when specifying
THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150
THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150 SECTION ONE A. Objective The objective of this guide is to provide Owners and General Contractors/Construction
STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS
ROOFING APPLICATION STANDARD (RAS) No. 133 STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS 1. Scope 1.1 This application standard has been developed to provide consistent information for the
SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE
SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel
SPECIFICATION Section 03450 - Insulated Precast Concrete Wall Panels
Lafarge/CPCI Guide Specification SPECIFICATION Section 03450 - Insulated Precast Concrete Wall Panels 1.0 General 1.1 Description.1 The General conditions of the Contract and Supplementary General Conditions
Section 04810 EXTERIOR STONE VENEER Full Mortar
Full Mortar PART 1 GENERAL 1.1 SUMMARY A. Section includes: 1. Portland cement mortar bed 2. Stone Veneer 3. Expansion and control joints. 4. Portland cement and hydraulic mortar and grout. 5. Sealer and
- - - - Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner
The Kelly Klosure pre-framed modular panel has 4 components that are factory finished to create an easy and versatile bolt-together system in the field. Steel Panel Frame Exterior Steel Sheeting Optional
Mark Cramer Inspection Services, Inc.
Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction
EDD-401. Stationary Louver Dual Drainable Blade. Application and Design. Standard Construction
Application and Design is a weather louver designed to protect air intake and exhaust openings in building exterior walls. Design incorporates a drainable head member and stationary horizontal blades to
Brick Veneer Construction
Brick Veneer Construction Check list of suggested tools & support items Claw hammer Tape measure 3/4" [19 or 20] Wood chisel Wood or plastic shims Pry bar Utility knife Caulking and caulking gun Power
CENTRIA FORMABOND Metal Composite Wall System
CENTRIA FORMABOND Metal Composite Wall System CENTRIA FormaBond is the only true metal composite panel wall system designed, manufactured and fabricated by a single, reliable national manufacturer and
March 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed