ARCHITECTURAL METAL WALL AND ROOF SYSTEMS /CEN BuyLine 9165
|
|
|
- Blaise McKenzie
- 9 years ago
- Views:
Transcription
1 ARCHITECTURAL METAL WALL AND ROOF SYSTEMS /CEN BuyLine 965
2 Distinctively INNOVATIVE. Distinctively SUSTAINABLE. Distinctively INSTALLED. CENTRIA is the place where owner and architect visions are realized, contractor challenges are conquered and discoveries are made for greener ways to build with metal. Through continuous pursuit of excellence and innovation in the design, engineering and manufacturing of exterior wall and roof systems, no other company does more to improve the aesthetics, durability and performance of our world s commercial buildings than CENTRIA. CENTRIA Formawall is the most advanced insulated metal composite wall system available today, providing outstanding thermal, moisture and air infiltration; integrated window, louver and sunshade offerings; and unprecedented design freedom from two design series Dimension Series and Graphix Series. All Formawall panels may be installed vertically or horizontally, and are often curved in a design. Formawall is simply the most complete wall system available today. 5 6 Insulating foam core, factory foamed-in-place, provides a thermally efficient exterior wall in either " [5mm] or " [76mm] thickness Durable metal skins provide impact resistance, strength for increased span capability and a built-in vapor barrier High performance coatings offer long-term performance, minimal maintenance and excellent color selection for your building s exterior Concealed clips and fasteners provide a sleek exterior appearance with proven long-term performance 5 Variable reveal sizes, /" [mm] to 6" [5mm] 6 For complete details and specifications visit CENTRIA.com FORMAWALL DIMENSION SERIES Parkwest Medical Center Knoxville, TN Architect: Earl Swensson Assoc. Inc Nashville, TN 6 Rainscreen and pressure equalization design with concealed sealant protects against water penetration
3 With Formawall Dimension Series, designers combine panels of varying thickness, width of reveal, and profile shape to give walls unique articulations and shadows. VARYING PANEL THICKNESS VARYING REVEALS STEEP SLOPE JOINTS DS-59 PROFILE DS-60 PROFILE Combine Formawall panels of varying thickness thick or thick. Specify the width of Steel Faced Formawall panel reveals anywhere from / to 6 in / increments. Aluminum Faced Formawall panel reveals, consult CENTRIA With optional steep sloped joints Formawall panels can be installed horizontally on an angle. Explore even more interesting wall articulations by incorporating optional thick panel profile shapes. ( wide only) DIMENSION SERIES DESCRIPTION Insulated metal composite wall panel system SUBSTRATE & CORE Standard /6 gage G-90 galvanized steel face and liner with HCFC-free polyurethane or polyisocyanurate foam-insulated core Optional gages available consult CENTRIA Optional stainless steel face sheet, 0 stainless steel, or 0 gage, smooth, embossed or striated Optional.00 Aluminum Face ( thick only), flat embossed or smooth striated JOINERY Horizontal oriented panel Rainscreen, pressure-equalized and drainable joinery, / nom. joint standard Vertical oriented panel Double tongue-and-groove, /8 nom. joint standard SURFACE FINISH Non-directional embossed flat or striated Interior Smooth flat or striated Non-directional embossed planked or flat Smooth planked PANEL WIDTH Available from 0 to 0 PANEL LENGTH (Steel Face) Smooth 6 max. Embossed striated 7 max. Embossed 7 max. Smooth striated 0 max. Duracast 8 max. PANEL LENGTH (Aluminum Face) Embossed 6 max. Smooth striated 6 max. PANEL THICKNESS/DEPTH OF REVEAL with -/6 deep reveal standard with -/6 deep reveal R VALUE panel with / reveal R panel with / reveal R R-Values are based on ASTM C6. Air films are included. FORMAWALL DIMENSION SERIES PE PERFORMANCE OPTION Formawall Dimension Series PE features an integral pressure equalized vent drainage channel for Formawall Dimension Series and Formawall Graphix Series exterior metal wall panels. The continuous air seal is not compromised by the seal plate venting and the plate transfers load to vertical support. This design creates two lines of defense against water intrusion /CEN BuyLine 965 SILVER 6 FEATURES & BENEFITS Pressure-equalized vertical & horizontal joinery Lightweight easy to handle and install Mitered panels permit clean, sharp corners and soffit transitions High strength panels offer increased span capability with less framing required Concealed clips, fasteners and sealants Trimless ends eliminate overlapping Cradle to Cradle SM Certification Integrated louvers and sunshades available Thermal break between face and liner offers efficient panel R-Values
4 INTEGRATION OPTIONS Formavue Windows Full line of windows for any framing type that integrate mechanically with Formawall panels for the highest performing panel/window interface C/S Sunshades Attractive and functional sunshades designed specifically for thermal and structural integration with Formawall panels and Formavue windows C/S Louvers High-quality line of fixed, drainable and storm-resistant louvers engineered specifically for fast and easy integration with Formawall panels Kalwall Translucent Windows Lightweight yet strong, these window systems combine the beauty of diffused, natural lighting with the functional qualities of high insulation, shatterproof construction and low maintenance FINISH OPTIONS SILVER Duracast Textured Finish Create a textured wall appearance with this durable textured coating. Available in eight standard natural earthtones Stainless Steel A strikingly beautiful choice of substrate that instantly elevates any project to a higher echelon Aluminum Available either smooth or embossed, aluminum facing offers increased design versatility and performance 6 For complete details and specifications visit CENTRIA.com FORMAWALL DIMENSION SERIES THE COMPLETE WALL SYSTEM Tacoma Public Utilities Administration Building Tacoma, WA Architect: BCRA Architects Tacoma, WA
5 Formawall Graphix Series American Eurocopter Columbus, MS Architect: JBHM Architects Columbus, MS /CEN BuyLine 965 Unique segmented construction Formawall Graphix Series segmented construction creates the illusion of multiple smaller panels from a single large wall panel easily and economically. Segments can be specified as frequently as every across the length of a Formawall panel for virtually unlimited grid like design possibilities. Add Formawall panel reveals / to 6 to a Graphix Series design for even more possibilities. Reduced length of weather joints leads to reduced risk of leaks. Faster erection/assembly. EASILY CREATE THESE COMPLEX PATTERNS FROM FEWER PANELS The appearance of nine individual panels is created from just three Graphix Series panels. NOTE: Graphix Series panels are not available with DS-59 or DS-60 panels, in stainless steel, or with a striated surface finish. Maximum panel length is 0. The appearance of 8 individual panels is created from just five Graphix Series panels. FORMAWALL GRAPHIX SERIES SILVER 5 6 GRAPHIX SERIES DESCRIPTION Insulated metal composite wall panel system SUBSTRATE & CORE Standard /6 gage G-90 galvanized steel face and liner with HCFC-free polyurethane or polyisocyanurate foam-insulated core Optional gages available consult CENTRIA Optional.00 Aluminum face ( thick only), embossed* and smooth JOINERY Horizontal oriented panel Rainscreen, pressure-equalized and drainable joinery, / nom. joint standard Vertical oriented panel Double tongue-and-groove, /8 nom. joint standard Segmented joint 5/8 x / deep embossment with factory applied black gasket, standard Max. segments per panel Min. length of segment SURFACE FINISH Non-directional embossed Smooth flat Interior Non-directional embossed planked or flat Smooth planked PANEL WIDTH Available from 0 to 0 PANEL LENGTH (Steel Face) 0 max. PANEL LENGTH (Aluminum Face) Embossed, Flat Overall Max. Length 6 Max. Length of Segment 6 Min. Length of Segment Max. Number of Segments Smooth, Flat Overall Max. Length 6 Max. Length of Segment Min. Length of Segment Max. Number of Segments PANEL THICKNESS standard consult CENTRIA * Length and reveal restrictions apply, please consult CENTRIA
6 SILVER Versawall and Versapanel (Cradle to Cradle certified) insulated metal composite panels install vertically to create a wall with advanced thermal and moisture protection properties. Architects enjoy the systems ability to provide long, uninterrupted sight lines up to 8 feet. Plus, Versawall and Versapanel wall panels can be coated with CENTRIA Duracast to provide a natural textured look. Versapanel is extra-versatile. With its bold standing seam, Versapanel doubles as a high-performance insulated roof when combined with its watertight, snap-on batten cap. VERSAWALL FLAT VERSAWALL PLANKED VERSAWALL STRIATED VERSAPANEL FLAT DESCRIPTION Insulated metal composite wall and roof system SUBSTRATES Standard 6/6 G-90 galvanized steel face and liner with HCFC-free foam insulated core Optional gages available, consult CENTRIA JOINERY Double tongue-and-groove joinery with factory-applied air and vapor seal Surface Finish Versawall Non-directional embossing, flat, striated or planked. For non-embossed and non-striated consult CENTRIA Versapanel Non-directional embossing, planked or flat Interior Non-directional embossing, planked Optional Duracast textured finish is available for Versawall and Versapanel wall applications, consult CENTRIA for panel length options PANEL WIDTH Versawall 0, 6 Versapanel 6 PANEL LENGTH 6 to 0 standard 8 max. consult CENTRIA PANEL THICKNESS Versawall, -/ nom. Versapanel -/, -/ R VALUE Versawall depth R -/ R0 R7 Versapanel -/ R -/ R9 R7 R-Values are based on ASTM C6 Air films are included. VERSAPANEL PLANKED 6 6 For complete details and specifications visit CENTRIA.com VERSAWALL & VERSAPANEL WALL & ROOF SYSTEMS Cal Train Maintenance Facility San Jose, CA Architect: STV Los Angeles, CA
7 /CEN BuyLine [5 ] or [76 ] [5 ] R- [76 ] R- 6 [9 ] [.66 ] 0 [6.0 ] 9-50
8 Bartle Hall Convention Center Ballroom Kansas City, MO Architect: HNTB Architecture Inc. Kansas City, MO Unlike ordinary ACM made by lamination, then fabricated into panels by a second party FormaBond is manufactured entirely by CENTRIA using a proprietary reaction injection molding process. The result is a stronger, flatter, finished ACM panel, with a pressure-equalized open, dry joinery. The panels joinery are engineered to prohibit the entry of water without using sealants. Yet, because of its open design, this joinery also provides optimum venting to allow wall cavities to dry any residual vapor or moisture. CENTRIA also provides window, louver and sunshade components that are engineered to integrate with FormaBond panels. Rout & Return Joinery 8 6 For complete details and specifications visit CENTRIA.com FORMABOND WALL SYSTEM DESCRIPTION Aluminum composite wall panel system SUBSTRATE & CORE Metal 0.0 nominal aluminum face and liner Core Highly cross-linked polymer that meets fire code requirements 8mm sheet thickness Smooth, Fusion, Embossed, Braided or Honeycomb Surface Finish Fusion Braided Embossed Honeycomb JOINERY All dry construction that is pressure equalized and provides ventilation to the inner wall cavity PANEL WIDTH Up to 60 PANEL LENGTH Up to 80 VARIABLE REVEALS From / to 6 in / increments. May also be colorized COATINGS Available in micas, metallics, and Fluorofinish PERFORMANCE High performance water testing Pressure-equalized joinery AAMA
9 The ribs of these six interchangeable panels are based on an identical asymmetrical form. Thousands of combinations of patterns, articulations, shadows and sight lines may be achieved by creatively combining these panels in either vertical or horizontal orientations. DESCRIPTION Concealed fastener pre-formed wall panel system SUBSTRATES Standard -8 gage G-90 galvanized steel Optional gage CS-60 and CS-660 only Galvalume steel, aluminum or stainless steel optional Smooth or embossed surface texture CONCEPT SERIES PROFILES Lengths up to 0 Concealed clips and fasteners Stand-off clip provides ventilation cavity and continuous drain plane behind panel May be installed vertically or horizontally Common joint design permits multiple profile integration Concealed fastener extended leg option /CEN BuyLine 965 CONCEALED CLIP With Standoff CS-00* CS-0 CS-60 CONCEALED Fastener Extended Leg Optional CS-60* CS-60* CS-660 Concealed with flush clip, consult CENTRIA SILVER Harrah s Chester Casino & Race Track Chester, PA Architect: SOSH Architects Atlantic City, NJ CONCEPT SERIES WALL SYSTEM OPTIONS MicroLine Extrusions Slim, wide aluminum trim for finishing around windows and doors, at corners and joints, and at the head and base of walls (horizontal or vertical panel) MicroSeam Corners Perfectly seamless inside or outside corners with no welds or pop rivets Liner Panels Used for creating an attractive, finished interior for a field-assembled wall Firewall System Field-assembled wall systems that employ layers of gypsum to provide UL -hour through -hour firewalls Quietwall System Field-assembled wall system with specific sound absorption or transmission loss values 9 6 *Patent No.: US D57,8; D58,98
10 These thirteen panels come in your choice of flat panels or with reveal depths of, or 6, with or without pencil bead stiffeners. By combining these panels in either a vertical or horizontal fashion, you re able to create thousands of combinations of attractive wall patterns and designs. IW-0A IW-A IW-A IW-A IW-A IW-5A IW-0A IW-A IW-0A IW-A IW-0A IW-A IW-60A SILVER 0 6 For complete details and specifications visit CENTRIA.com IW SERIES WALL SYSTEM DESCRIPTION Concealed fastener pre-formed wall panel system SUBSTRATES Standard -8 gage G-90 galvanized steel Optional gage IW-A, IW-A and IW-60A Galvalume steel, aluminum or stainless steel optional Smooth or embossed surface texture IW SERIES PROFILES Lengths up to 0 Horizontal or vertical wall installation Lock-joint design of IW-0A through IW-A makes panels interchangeable swaged laps are available in gages lighter than 8 Not available for IW-A, IW-A, IW-5A and IW-60A OPTIONS MicroLine Extrusions Slim, wide aluminum trim for finishing around windows and doors, at corners and joints, and at the head and base of walls (horizontal panels only) MicroSeam Corners Perfectly seamless inside or outside corners with no welds or pop rivets Liner Panels Used for creating an attractive, finished interior for a field-assembled wall Firewall System Field-assembled wall systems that employ layers of gypsum to provide UL -hour through -hour firewalls Quietwall System Field-assembled wall system with specific sound absorption or transmission loss values
11 California State University, Stanislaus Turlock, CA Architect: Perkins & Will Architecture San Francisco, CA DESCRIPTION Exposed fastener pre-formed wall and roof panel systems SUBSTRATES Standard -8 gage G-90 galvanized steel* Galvalume steel, aluminum or stainless steel optional Smooth or embossed surface texture EXPOSED FASTENER PROFILES Horizontal or vertical wall installation Wall and roof installation Lengths up to 0, consult CENTRIA for longer lengths * Super-Rib is not available in gage /CEN BuyLine 965 SUPER-RIB MR-6 BR5-6 STYLE-RIB TR-6 ECONOLAP-/ ECONOLAP-/ EXPOSED FASTENER WALL & ROOF SYSTEM CENTRIA manufactures seven exposed fastener profile panels. In addition to wall panels, these versatile panels may also be used for roofing, and soffit applications, they are readily curved for walls, canopies, awnings, parapets, column and beam wraps and more. Like all CENTRIA profile panels, these panels can be mixed and matched to create virtually unlimited designs. OPTIONS MicroLine Extrusions Slim, wide aluminum trim for finishing around windows and doors, at corners and joints, and at the head and base of walls (BR5-6, Style-Rib, TR-6 and Econolap / Horizontal only) MicroSeam Corners Perfectly seamless inside or outside corners with no welds or pop rivets (all profiles except Econolap / ) Liner Panels Used for creating an attractive, finished interior for a field-assembled wall Firewall System Field-assembled wall systems that employ layers of gypsum to provide UL -hour through -hour firewalls Quietwall System Field-assembled wall system with specific sound absorption or transmission loss values Curving is available in a wide selection of exposed fastener profiles, finishes and colors to match virtually any architectural, commercial or industrial application. 6
12 / /" /8 /8 /8 / / / 0 /8 7/ /6 5/6 0 /8 /6 0 /8 9/ /6 6 -/ -/ 0% /8" [0 ] ] 00 75
13 DESCRIPTION SRS Structural standing seam roof system /CEN BuyLine 965 SUBSTRATES SRS -0 gage SRS -8 gage G90 galvanized steel, Galvalume, stainless steel, and aluminum PANEL WIDTH, 6, 8 PANEL DEPTHS SRS SRS PANEL LENGTH Factory-formed up to 8-0 max. standard, up to 60-0 optional Field-formed 0-0 max. SRS Oil canning within industry standard guidelines as defined by MCA is not a cause for rejection. SRS SILVER SRS STRUCTURAL STANDING SEAM ROOF SYSTEMS 6 DESCRIPTION SRS PLANKED SRS PENCIL BEAD SRS PLANKED Concealed fastener pre-formed wall panel system OTHER ROOF PROFILES ARCHITECTURAL DESIGN PANELS ADP 00 ADP 00C OTHER STRUCTURAL DESIGN PANELS SDP 75 SDP 00 ADP 00B
14 COATING SYSTEMS AND SUBSTRATES Distinctively Protected. CENTRIA has devoted more than 00 years to the art and science of producing color coated metal walls and roofs that impart the very best in aesthetics and performance. This includes a wide variety of high-quality coating systems, a full palette of colors and a range of substrates and surface textures to meet even the most demanding environmental conditions. THE INDUSTRY S WIDEST ARRAY OF COLORS CENTRIA offers you a full array of colors (see CENTRIA Colors brochure) including micas and bright metallics. CUSTOM COLOR MATCHING CENTRIA is also equipped with the latest color matching technology enabling us to provide fast turnaround on even the most unique or unusual colors. For complete information on CENTRIA coating systems, contact us for a copy of our coatings brochure. FLUOROFINISH * A Kynar 500, or Hylar 5000 coating providing good durability. 0.8 mil [0 micron] nominal Color Coat 0. mil [5. micron] nominal Primer Substrate DURAGARD PLUS A premium, high build architectural coating providing the ultimate in color retention and fade resistance. 0.8 mil [0 micron] nominal Polyvinylidene Fluoride Clear Coat* 0.8 mil [0 micron] nominal Polyvinylidene Fluoride Color Coat* 0.8 mil [0 micron] nominal Primer Substrate Duragard 0.8 mil [0 micron] nominal Polyvinylidene Fluoride Color Coat* 0.8 mil [0 micron] nominal Primer Prismatic Series Colors Fluorofinish, Duragard and Duragard Plus 6 For complete details and specifications visit CENTRIA.com Unless specified otherwise, CENTRIA will provide a standard backer coat on the reverse side of single skin panels. Color may vary. Polyester Arctic Ice is the standard finish offering for the interior surfaces of foam panels. Other finishes available upon request. C ENERGY STAR qualified cool roofing color for low* or steep* slope applications CS ENERGY STAR qualified cool roofing color for steep* slope application Standard Duracast finish color. Consult CENTRIA for custom colors. Low Slope Roofs: - :, Steep Slope Roofs: > : Colors shown are for preliminary selection only. Printed colors can vary from actual painted material. Contact CENTRIA for painted metal samples before final selection. Cost of CENTRIA coatings may vary depending on color and finish selection. NOTE: Because of the differences in the formulation and application properties of spray-applied coatings versus coil coatings, a slight color variation is likely to occur when matching coatings of these different types.
15 /CEN BuyLine 965 SUNDANCE MICA* -COAT FINISH A Kynar 500, Hylar 5000 or FEVE-based coating providing good durability. 0.8 mil [0 micron] nominal Color Coat 0. mil [5. micron] nominal Primer Substrate SUNDANCE AM ALUMINIUM METALLIC -COAT FINISH A quality, durable coating providing the iridescence and refl ectivity of a metallic surface. 0.5 mil [.7 micron] nominal Polyvinylidene Fluoride Clear Coat* 0.8 mil [0 micron] nominal Polyvinylidene Fluoride Color Coat* 0. mil [5. micron] nominal Primer Substrate DURACAST TEXTURED FINISH SYSTEM** Factory-applied coating with natural aggregate matrix providing the look and feel of precast. Available exclusively for Formawall Dimension Series, Formawall Graphix Series and Versawall panels. Acrylic and Natural Aggregate Matrix 0.8 mil [0 micron] nominal Polyester 0. mil [5. micron] nominal Primer Substrate ** Subject to minimum quantity requirements. VERSACOR ULTRA A premium, high build, multi-layer coating for applications where corrosion and abrasion resistance is more important. VERSACOR ULTRA PF An excellent coating for corrosive architectural applications. 0.8 mil [0 micron] nominal PVDF Coat.0 mil [75 micron] nominal Versacor Ultra Barrier Coat Primer Substrate VERSACOR ULTRA TF and HF A coating merging the superior corrosion resistance of the Versacor Barrier Coat Primer with the durability of a Urethane Finish..5 or.0 mil [8 or 75 micron] nominal Urethane Coat.0 mil [75 micron] nominal Versacor Ultra Barrier Coat Primer Substrate What is Reverse Side Coating Protection? On CENTRIA s Profi led Series panels with a Versacor Ultra coating system, an additional Versacor Barrier Coating Primer is applied to the interior of the metal substrate. Then either a wash coat, Urethane top coat or primer are applied over the barrier coat. This additional coating protects the metal against corrosion from the interior and at lap conditions. Another reason Versacor Ultra provides superior protection. AVAILABLE SUBSTRATES Standard G-90 hot-dip galvanized steel conforming to ASTM A9 and ASTM A65 structural quality Galvalume steel, unpainted hot-dip coated with aluminum-zinc alloy conforming to ASTM A9 and ASTM A79 Stainless Steel**, Type 0 AISI architectural grade alloy; austenitic, non-magnetic, non-glare surface; slight variation in surface fi nish Aluminum Alloy 00 or 505 and for standing seam roof panels, 00**, available in smooth surface as a substrate Sundance Series Colors Sundance Mica -coat 5 6 Sundance AM Aluminum Metallic -coat Custom colors may require an additional clear and/or barrier coat. Consult CENTRIA for details. Duracast Dove Gray Lee Ivory Light Gray Slate Gray Light Seawolf Surrey Beige Limestone Off-White *Polyvinylidene Fluoride (PVDF) coat contains 70% Kynar 500 or Hylar 5000 resin. Kynar 500 is a Reg. TM of Atofi na Chemicals, Inc. Hylar 5000 is a Reg. TM of Solvay Solvents, Inc. Galvalume is a Reg. TM of BIEC International, Inc. NOTE: Galvalume, Stainless and Aluminum may not be available for all product profi les or coating systems. Consult CENTRIA sales. Galvalume offers improved heat resistance only when used unpainted.
16 NORTHEAST REGION SOUTH CENTRAL REGION WEST REGION Baltimore, MD Phone: Fax: Boston, MA Phone: Fax: Hartford, CT Phone: Fax: Newark, NJ Phone: Fax: New York, NY Phone: Fax: Philadelphia, PA Phone: Fax: Pittsburgh, PA Phone: Fax: Syracuse, NY Phone: Fax: Washington, DC Phone: Fax: Atlanta, GA Phone: Fax: Charlotte, NC Phone: Fax: Cincinnati, OH Phone: Fax: Detroit, MI Phone: Fax: Greenville, SC Phone: Fax: Indianapolis, IN Cell: Fax: Memphis, TN Phone: Fax: Milwaukee, WI Phone: Fax: Sarasota, FL Phone: Fax: Western Michigan Phone: Fax: Beaver Grade Road, Moon Township, PA Phone: Fax: Dallas, TX Phone: Fax: Denver, CO Phone: Fax: Des Moines, IA Phone: Fax: Houston, TX Phone: Fax: Minneapolis, MN Phone: Fax: Phoenix, AZ Phone: Fax: San Francisco, CA Phone: Fax: St. Louis, MO Phone:.. Fax:..686 Seattle, WA Phone: Fax: Southern California (Los Angeles) Phone: Fax: Office of Business Development Phone: CENTRIA products have inherent sustainable characteristics. Our products are primarily composed of steel and other metals which have been, and can repeatedly be, recycled. Our factory foamed insulation provides an insulation value in excess of alternative systems saving energy cost and fuel resources. CENTRIA also offers specific high-performance, sound-reducing products to protect the environment from machine or process-generated noise pollution. Reference SWT 09/09 5M PG Copyright 00 CENTRIA Printed in U.S.A.
ARCHITECTURAL METAL WALL AND ROOF SYSTEMS. 07 40 00 /CEN BuyLine 9165
ARCHITECTURAL METAL WALL AND ROOF SYSTEMS 07 40 00 /CEN BuyLine 9165 CENTRIA FORM MEETS FUNCTION CENTRIA is the world s leading innovator and manufacturer of high-performance building enclosure systems,
SECTION 07410 PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK
SECTION 07410 PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK A. This section covers the pre-finished, pre-fabricated Architectural standing seam roof system. All metal trim,
INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT.
INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT. awipanels.com From freezing, sub-zero temperatures to Contents dry heat or high humidity, Mother Nature continually tests the limits of building envelopes. That's
CENTRIA SRS3 Structural Standing Seam Metal Roof Panels
CENTRIA SRS3 Structural Standing Seam Metal Roof Panels CENTRIA SRS3 Structural Standing Seam Metal Roof Panels are manufactured in many different coil coating systems and painted with a wide variety of
PRODUCT SPECIFICATIONS
LokSeam LokSeam 12" One of the most versatile architectural metal panels available today, LokSeam by ABC, is a snap-together, concealed fastener, standing seam roof system with a 13/4" tall vertical rib,
UNIVERSITY OF NEBRASKA MAMMEL HALL COLLEGE OF BUSINESS
UNIVERSITY OF NEBRASKA MAMMEL HALL COLLEGE OF BUSINESS Formawall PE provides a high performance insulated panelized exterior metal wall system that s suited for an endless array of design options. Joe
SECTION 07 61 13 STANDING SEAM METAL ROOFING
SECTION 07 61 13 STANDING SEAM METAL ROOFING PART 1 GENERAL 1.01 SCOPE OF WORK A. The Work shall include all labor, materials, equipment and supervision required to complete the work of the above referenced
GUIDELINE SPECIFICATIONS
GUIDELINE SPECIFICATIONS GORDON SOFFIT-SHIELD - An Exterior Metal Soffit System DIVISION 05 5800 or DIVISION 07 7700 Note To Specifier: SOFFIT-SHIELD should be installed by tradesmen that are experienced
SECTION 07400 STANDING SEAM METAL ROOF
SECTION 07400 STANDING SEAM METAL ROOF PART 1 - GENERAL 1.01 SECTION INCLUDES A. Work described in this section includes pre-formed standing seam metal roofing system complete with clips, perimeter and
- - - - Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner
The Kelly Klosure pre-framed modular panel has 4 components that are factory finished to create an easy and versatile bolt-together system in the field. Steel Panel Frame Exterior Steel Sheeting Optional
EDD-401. Stationary Louver Dual Drainable Blade. Application and Design. Standard Construction
Application and Design is a weather louver designed to protect air intake and exhaust openings in building exterior walls. Design incorporates a drainable head member and stationary horizontal blades to
metal Duil~ing manufacturers Association
metal Duil~ing manufacturers Association ApplicatiDns metal Building Systems Conventional Buildings Retrofit Roofing Projects l~e Perfect Cover.One of the most important technological advances in building
Metal Wall Panels. Colorweld 300 Architectural Finishes
Metal Wall Panels Colorweld 300 Architectural Finishes Metal Wall standard architectural finishes These products are protected and colored with high-performance Colorweld 300 coatings ensuring precise
STANDING SEAM METAL ROOFING PANELS
STANDING SEAM METAL ROOFING PANELS Roof it for the last time. ENERGY EFFICIENCY WITH STYLE & DURABILITY METAL ROOFING FOR RESIDENTIAL AND COMMERCIAL APPLICATIONS. Featuring the TITAN Cool Roof Reflective
Springlok Flashing System
Springlok Flashing System Why Fry Reglet? Fry Reglet s comprehensive selection of moisture prevention products offer the ultimate in protection from the elements. Available nationwide in a variety of materials
CENTRIA FORMABOND Metal Composite Wall System
CENTRIA FORMABOND Metal Composite Wall System CENTRIA FormaBond is the only true metal composite panel wall system designed, manufactured and fabricated by a single, reliable national manufacturer and
Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood
Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood Section 07411 Metal Roof Panels Part 1 General 1.1 Summary A. This section includes the following: a. Factory-formed
SECTION 07410 METAL ROOF & WALL PANELS
This document specifies Metal Roofing Systems prefinished factory formed metal roofing marketed as MRS System 2500 steel and aluminum roofing systems and includes MRS flashing and Trim. MRS finish is a
METAL ROOF & WALL SYSTEMS
07 40 00/MCE BuyLine 3423 CATALOG 2006 METAL ROOF & WALL SYSTEMS ARCHITECTURAL COMMERCIAL RESIDENTIAL Since 1963, McElroy Metal has served the construction industry with quality products and excellent
Standing Seam Roof Systems
Standing Seam Roof Systems REAL PEOPLE. REAL PRODUCTS. REAL SOLUTIONS. www.a-s.com Building Benefits You Can Expect From A&S Materials Standing Seam roof panels weigh a relatively modest 11/2 pounds per
TABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"
2 TABLE OF CONTENTS SECTION 1: What is a Standing Seam Metal Roof PAGE 3 SECTION 2: Common Types of Standing Seam Metal Roofs..PAGE 5 SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE
CENTRIA Exposed Fastener Series Metal Wall Panels
CENTRIA Exposed Fastener Series Metal Wall Panels CENTRIA Exposed Fastener Series Metal Wall Panels are a versatile design choice for both new and retrofit projects. Exposed Fastener Metal Wall Panels
Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023
Specifications Preformed Metal Wall and Roof Panels Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023 Section 07410 Preformed Metal Wall and Roof Panels Structural
COMMERCIAL BUILDING APPLICATIONS
EXPANDED POLYSTYRENE FOR COMMERCIAL BUILDING APPLICATIONS www.falconfoam.com Commercial Building Ap Expanded Polystyrene Insulation Falcon Foam leads the commercial building industry with products that
3955-01 Santa Barbara Lounge 24W x 31H x 24D AH22
3955-01 Santa Barbara Lounge 24W x 31H x 24D AH22 T H E L O G I C w o r k O F F I C E S E R I E S h b f L O G I C w o r k O F F I C E S E R I E S A D A P T S T O E V E R C H A N G I N G W O R K P L A C
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.
Light Architecture. Colors Sweden. Light
Light Architecture Danpalon is the complete daylighting solution offering exceptional quality of light, thermal insulation and UV protection with a rich non-industrial visual appeal. The Danpalon system
ROOF FLASHING SPRINGLOK FLASHING SYSTEM FEATURES & BENEFITS PRODUCT DESCRIPTION
SPRINGLOK SYSTEM PRODUCT DESCRIPTION FEATURES & BENEFITS Fry Reglet offers five flashing systems, each tailored for a particular type of substrate so you can get exactly what you need. SM Surface mounted
SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING
SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING PART ONE GENERAL DESCRIPTION This section includes pre-formed standing seam metal roofing and related flashings, closures, trim and accessories including,
800.406.7387 www.metalsales.us.com. Light Gauge Panels. Metal Sales Manufacturing Corporation
800.406.7387 www.metalsales.us.com Light Gauge Panels Metal Sales Manufacturing Corporation The Metal Sales Advantage Metal Sales Manufacturing Corporation continues to lead the industry with time-tested
THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150
THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150 SECTION ONE A. Objective The objective of this guide is to provide Owners and General Contractors/Construction
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
Holiday Inn Express & Suites Covington (Newton County) 1. Standing-seam metal roofing, custom fabricated.
PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Standing-seam metal roofing, custom fabricated. 1.2 SUBMITTALS A. Product Data: For each type of product indicated. B. Shop Drawings: Show installation
WATER LEAKAGE IN GLAZED CURTAIN WALL SYSTEMS:
WATER LEAKAGE IN GLAZED CURTAIN WALL SYSTEMS: BY WILLIAM D. SMITH Figure 1 Four Corporate Center, Franklin, TN. Architect: Little & Associates,Charlotte, NC. Gen. Contractor: Ray Bell Const. Co., Nashville,
JANUARY, 2016 TR-7100 Windows (Fixed) 1 EC 97909-071 085113 ALUMINUM WINDOWS Guide Specs
JANUARY, 2016 TR-7100 Windows (Fixed) 1 EC 97909-071 085113 ALUMINUM WINDOWS Guide Specs SECTION 085113 ALUMINUM WINDOWS This suggested guide specification has been developed using the current edition
stand the tests of time, & economics
Roofs that stand the tests of time, THE elements & economics Architectural metal systems WHY METAL ROOFING? AMS metal standing seam roofs provide the longest life cycle of any common roof in use today,
Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.
Installation Guide Before you begin, take the time to read this entire guide to clearly understand the requirements and steps to follow for proper installation. Warning Do not install defective material.
Peel & Seal Self-Stick Roofing Solutions
Peel & Seal Self-Stick Roofing Solutions Ideal for Low Slope Applications Waterproof and Weatherproof Energy Efficient Tough and Durable Versatile, Effective Sealing Around Protrusions Perfect for Vents,
COLORADO MODEL. 35 x 65 SPECIFICATIONS
COLORADO MODEL 35 x 65 SPECIFICATIONS Dimensions: Roof Dimensions 35-0 x 65-0 Column Dimensions (center to center) 31-0 x 30-6 Minimum Clearance 14-0 Roof Height @ Peak ±18-8 Curved Roof ±42-6 radius Square
Nucor VR16 II TM Vertical Rib Standing Seam Roof System
Nucor VR16 II TM Vertical Rib Standing Seam Ro System www.nucorbuildingsystems.com Nucor VR16 II Vertical Rib Standing Seam Ro Perfect for the Marketplace The Nucor Building Systems VR16 II Ro Panel is
DIVISION 07. Architectural Sheet Metal. Weathertight Warranties. Rollforming Equipment. 50+ Years of SSMR, Installation & Technical Experience
DIVISION 07 Engineered Metal Roofing Systems Architectural Sheet Metal Specialty Coil & Sheet Products Weathertight Warranties Rollforming Equipment Accessories & Components 50+ Years of SSMR, Installation
Miami-Dade Qualified Drainable Blade Louvered Penthouse
Application and Design is a gravity intake or exhaust louvered penthouse. Model incorporates high performance horizontal drainable style blades. Meets the performance requirements established by the Florida
DENVER MODEL 30 X 30 SPECIFICATIONS
DENVER MODEL 30 X 30 SPECIFICATIONS Dimensions: Roof Dimensions 30-0 x 30-0 (4) Columns (Center to Center) 25-6½ x 25-6½ Minimum Clearance 8-0 Roof Height @ Peak Dependent on Col. Ht. Hip Roof 4:12 pitch
238T Standing Seam Metal Roof System (SSMRS)
238T Standing Seam Metal Roof System (SSMRS) Text in red are instructions to the specifier and should be deleted. Text in blue are choices that need to be made, with those not selected, deleted. McElroy
Built to Last. Built for Beauty. Good. Solid. Logix. TM
Built to Last. Built for Beauty. Good. Solid. Logix. TM Quality, Value and Service Introducing LOGIX Insulated Concrete Forms. Based on the simple concept of interlocking blocks, LOGIX ICF gives you a
METAL BUILDING SYSTEMS
BUILDING SYSTEMS The Brand of Choice METAL BUILDING SYSTEMS www.nucorbuildingsystems.com Building Systems The Brand of Choice Nucor Building Systems, a division of Nucor Corporation, is one of the most
Ethernet Access (Formerly Converged Ethernet Access) Operations Manual
Ethernet Access (Formerly Converged Ethernet Access) Operations Manual 1. Service Description. Ethernet Access (formerly known as Converged Ethernet Access or Multi-Service Ethernet Access) provides dedicated
DELTA Premium Moisture Management Systems for Foundations.
DELTA protects property. Saves energy. Creates comfort. DELTA Premium Moisture Management Systems for Foundations. DELTA Premium Moisture Management Systems provide the best protection for foundations.
1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.
SECTION 075416 - PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system. 1.2 PERFORMANCE REQUIREMENTS A. Solar Reflectance
TremLock Metal Roofing and Wall Solutions
TremLock Metal Roofing and Wall Solutions ROOFING & BUILDING MAINTENANCE TABLE OF CONTENTS PRODUCT systems overview APPLICATION TremLock Roofing and Wall Solutions...4 STANDING SEAM TremLock T-238 Roof,
Sun Windows General Information Sun New Construction Window Installation Instructions
Sun Windows General Information Section 1 G F H H H A. Apply Weather Resistive Barrier B. Apply Sill Flashing Tape C. Place Waterproof Sill Shims D. Caulk Back of Nail Fin Sides & Top, Set Window, Fasten
Building Owners Guide to a Duro-Last System!
Building Owners Guide to a Duro-Last System Table of Contents Section 1: Introduction to Duro-Last Roofing Systems Section 2: Benefits of a Duro-Last Roofing System Section 3: Comparing a Duro-Last Roof
City of San Diego, CWP Guidelines
PART 1 -- GENERAL SECTION 08520-1.1 WORK OF THIS SECTION City of San Diego, CWP Guidelines A. The WORK of this Section includes providing aluminum windows with frames, bracing, glazing attachments, screens,
Preformed Metal Roofing and Siding
Page -1-1. GENERAL 1.1. Description This specification along with the drawings covers the furnishing of all material, products, equipment, accessories, tools, services, transportation, labor and supervision
CB-100 CB-150 CS-100 SL-100 SL-150 SLZ-1000
CB-100 CB-150 CS-100 SL-100 SL-150 SLZ-1000 Details and Installation Guide October 2013 All information, descriptions and dimensions in this manual are current at the time of printing. As always, Custom-Bilt
Technical Data Honeycomb Door Leaf 8-1-99
8--99 8-/8 8-7/8 B 8-/4 A A Dim. A Leaf Width B ELEVATION F DESIGN Vertical edge seams mechanically interlocked Square hinge and lock edges 4-/ x.4 full mortise hinge prep Gov. 60/6 cyl lock prep...prefix
foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.
Skylight Installation Instructions This document provides instruction and guidelines for installation of both curb mount (CM) and self flashing (SF) unit skylights on flat, pitched (> or equal to 3/12
A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, 2012. All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA
Page 1 of 10, Addendum No. 3 Temporary Garage Structure City of Chelsea, MA November 5, 2012 CBI Job No.: 12055-A A D D E N D U M # 3 DATE: November 5, 2012 TO: FROM: PROJECT: All Bidders Jenne dos Santos,
DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 41 13 METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC
0 ICC ES Report ICC ES (800) 423 687 (62) 699 043 www.icc es.org 000 Most Widely Accepted and Trusted ESR 3422 Reissued 09/201 This report is subject to renewal 09/2016. DIVISION: 07 00 00 THERMAL AND
SECTION 07411 STANDING SEAM METAL ROOFING
PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following: 1. Standing-seam metal roof. 2. Metal gutters. 1.2 DEFINITIONS A. Metal Roof Panel Assembly: Metal roof panels, waterproofing membrane (underlayment),
DIVISION 7 - THERMAL AND MOISTURE PROTECTION
DIVISION 7 - THERMAL AND MOISTURE PROTECTION Note: This is a guide for Designers only. Contents shall not be used in lieu of specifications as part of the Designer s Contract Documents. SECTION 07 1000
CHAPTER 7: Building Systems ROOFING SYSTEMS
ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen
Metal Building Systems Installation and Flashings & Details Guide. Table of Contents
Table of Contents Section Page Notes to Designer/User..................1-2 Map of Typical Roof Conditions............3 Fastener Placement.......................4 Fastener Selection........................5
PART 1 GENERAL 1.1 SECTION INCLUDES
J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including
SECTION 08 5656 GUARDA SECURITY WINDOW SCREENS
Page 1 of 5 SECTION 08 5656 GUARDA SECURITY WINDOW SCREENS Guarda Security Window Screens in this specification are appropriate for use in windows, storefronts, curtain walls, vents, and any other applications
VERTICAL LOCK Table of Contents
Table of Contents TABLE OF CONTENTS Vertical Lock Product Data Sheet... 2 Vertical Lock Engineering Data... 3 General Information... 6 Material Testing... 7 Panel Overview... 8 Handling Material & Storage
Quality Windows And Doors. Great Service. Exceptional Value.
Quality Windows And Doors. Great Service. Exceptional Value. As A Matter Of Fact, Our Windows And Doors Are The Best. Since 1985 North Star has been an industry leader in the manufacture of attractive
ATLANTA MODEL SPECIFICATIONS
ATLANTA MODEL 50 SPECIFICATIONS Dimensions: Roof Dimensions (point to point) 50-0 Column Dimensions (out to out of columns) 44-0 Eave Height 8-0 Roof Height @ Peak ±21-8⅞ Hip Roof 6:12 pitch Square Feet
GreenGuard Housewrap Installation Guide
000768PACBPHW_Flashing Bro 5/23/03 2:52 PM Page 1 For the most current product information, go to www.green-guard.com. Pactiv Building Products believes the information and recommendations herein to be
metals LLC Metal roofing ON-DEMAND
Metal roofing ON-DEMAND PRODUCT CATALOG About Drexel Metals contents Metal Roofing on Demand PAGES 4-5 Certified Installer Program & Warranties PAGES 6-7 Engineered Metal Roof Systems PAGES 9-15 Solar
Atlanta Rankings 2014
Atlanta Rankings Major National Magazine and Study Rankings BUSINESS FACILITIES Metro Business Rankings Lowest Cost of Doing Business 2. Orlando, FL 3. Charlotte, NC 4. San Antonio, TX 5. Tampa, FL 6.
Tundra Series Windows January 2016
Tundra Series Windows January 2016 New Construction Installation Instructions Nail Fin, J-Fin and Brickmold Aplications product. ATTENTION! Read and understand all installation instructions before installing
Coastal Metal Service
Coastal Metal Service Manufacturers of Quality Metal Roofing and Siding Products 25 th ANNIVERSARY Manufacturers of Quality Metal Roofing & Siding Products Coastal Metal Service is a Quality Manufacturer
Adding value to the finest homes in Virginia for 52 years! years
52 years Family Owned and Trusted! Adding value to the finest homes in Virginia for 52 years! James Hardie Fiber Cement Siding Insulated Vinyl Windows Insulated Vinyl Siding Vinyl Railings, Columns, Entry
Window Installation Instructions
Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for
SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront
PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system
STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS
ROOFING APPLICATION STANDARD (RAS) No. 133 STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS 1. Scope 1.1 This application standard has been developed to provide consistent information for the
DIVISION 23 HEATING, COOLING, AIR CONDITIONING AND VENTILATION
SECTION 230713- ALUMAGUARD ENGINEER SPECIFICATION DIVISION 23 HEATING, COOLING, AIR CONDITIONING AND VENTILATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract,
A. Double lock standing seam, single element, metal roof panels.
Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions SECTION 07 41 13 METAL ROOF PANELS Morin Metal Panels Double Lock Standing Seam Metal Roof Panels PART 1 - GENERAL 1.1
HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS
BSW HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS BSW is a fully reinforced Pre-Applied system membrane designed for horizontal and vertical external blind-side
!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035
Decra Plus Drawing no DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 Description Shown In Decra Brochure Most Commonly Used Detail t~êã=oççñ=b~îéë=aéí~áä=b~îéë=lîéêü~åö=táíü=fåëìä~íéç=c~ëåá~=~åç=pçññáí
HOMEOWNER S ENHANCEMENT GUIDE. Chapter 8: New Houses in the Neighborhoods
HOMEOWNER S ENHANCEMENT GUIDE Chapter 8: New Houses in the Neighborhoods? NEW CONSTRUCTION There are limited opportunities for new singlefamily home construction in most of Henrico County s midcentury
ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS
ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS 1. 2. 3. 3.0 Scope 1.1 This application standard shall be used where the authority having jurisdiction has adopted its use, and
SECTION 07 42 13 METAL WALL PANELS
Mitsubishi Plastics Composites America, Inc. 401 Volvo Parkway Chesapeake, VA 23320 Phone: (800) 422-7270 Fax: (757) 436-1896 E-mail: [email protected] www.alpolic-northamerica.com This MANU-SPEC utilizes
Determining the Right Molding Process for Part Design
Determining the Right Molding Process for Part Design How RIM Molding Advantages Compare with Traditional Production Technologies Page 2 Introduction This White Paper details the part production processes
Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide
Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer /Installers.. 1 Fastener Placement and Selection.2-3
ABSeam Panel Overview and Installation Instructions
82 Garden Spot Road Ephrata, PA 17522 717-445-6885 35 Ridge Road Newville, PA 17241 717-776-5951 ABSeam Panel Overview and Installation Instructions Applications: The ABSeam panel is an architectural panel
western transforming space window systems series 670 a new option for hinged window line
western window systems a new option for transforming space series 670 hinged window line Western Window Systems a new way to live, a better way to build Since opening in 1959 in Phoenix, Western Window
EAST LYME HIGH SCHOOL
Overview: 1971 N 1966 GYM 1966 CLASSROOM WING 1966 AUD. 1971 GYM 1998 1998 POOL EAST LYME HIGH SCHOOL Original 1966 Building: The original East Lyme High School was constructed in 1966 and was composed
Number of Liver Transplants Performed 2003-2004 Updated October 2005
PEDIATRIC CENTERS PEDIATRIC TRANSPLANT CENTERS Number of Liver Transplants Performed 2003-2004 Updated October 2005 University of Alabama Hospital, Birmingham, AL 3 2 1 University Medical Center, University
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590
Confort 26. Sliding Systems. Sapa Building System
Confort 26 Sliding Systems Sapa Building System Confort 26 is Sapa s thermally insulated sliding system for windows and doors. Available as two- and three-rail solution. Among its features, there are
Fire Resistant Systems
Fire Resistant Systems A R C H I T E C T U R A L A L U M I N I U M G L A Z I N G S Y S T E M S Fire Resistant Systems Introduction Kawneer are pleased to introduce two new comprehensive Fire Resistant
eading Performance Solutions
eading Solutions Manage Risk Save Time and Money Grow Business Responsive Leadership As a construction professional, you face countless challenges. Every day you are expected to finish projects efficiently
Final inspections are completed by site visit only. Access to fenced yards shall be planned.
ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,
I-Line - Snap-On Feature
Oct 2012 I-Line - Snap-On Feature DATA SHEET Snap-On features - Guaranteed truelines every time Bailey I-Line Snap-On is an architectural cladding feature offering creative possibilities for architects
The Peak of Protection
FUTURE ROOF The Peak of Protection Our Future is Your Satisfaction E l e g a n t Imagine the look of heavy wood shake without all the problems associated with wood. Future Shake by Future Roof Systems
ANGELOUECONOMICS 2012 INDUSTRY HOTSPOTS
ANGELOUECONOMICS 2012 INDUSTRY HOTSPOTS INDUSTRY SPECIALIZATION OF AMERICA'S 100 LARGEST METROPOLITAN AREAS INDUSTRY CLUSTERS 19-24 (of 36) ABOUT THE RANKINGS In the 21 st Century, the engines that drive