utopia Split Systems DC Inverter 7kW-14kW G8 5kW-25kW
|
|
|
- Russell Lynch
- 10 years ago
- Views:
Transcription
1 utopia DC Inverter 7kW-14kW G8 5kW-25kW Split Systems
2 Contents Company profile 4 Product range overview 6 Features and benefits 8 DC Inverter 12 Utopia G8 24 Utopia centrifugal 40 Total heat exchanger 42 Control systems 44 Set-up and operation 46 Lon interface 48 Optional parts 50 3
3 Air Conditioning from HITACHI can justifiably be described as the art of exploiting the latest ideas and developments in technology to create a range of innovative products which provide a more comfortable and more productive environment in which people can happily live and work. It is also an art executed with a responsible concern for protecting the environment. Ecological thinking begins at the very first stages of new product design and continues throughout production, installation procedures, equipment and operation. Specifiers and users alike can always be assured that performance and costs are not the only parameters by which HITACHI products can be judged. To achieve success with such objectives on a global scale requires not only enormous resources but also a commitment to the future. As one of the largest companies in the world, with over 321,517 employees, HITACHI is well positioned to undertake this commitment with confidence that comes from successfully responding to the changing needs of people for over 90 years. worldwide. In 1993 HITACHI invested in a new purpose built, state of the art factory (HAPE) in Barcelona, Spain. The site of the factory was carefully chosen to accommodate further building on its 40,000 square meter site. The creation of a European manufacturing facility and customer training centre helps reduce production costs, speed up delivery times and enables full support to be given to all customers. HITACHI s advanced air conditioning products are specified all over the world, wherever there is a requirement for ultimate performance and cost effective, long term reliability. A wide range of units coupled with a choice of advanced control systems mean HITACHI can provide solutions to meet every possible air conditioning application or specification. Authorised Distributors all over the world contribute their own specialised technical support and practical assistance to provide individual system designs, commissioning and after sales service. HITACHI Authorised Distributors are committed to providing an unrivalled support from a combination of experienced engineers, local product and spare parts stock, Hitachi Air Conditioning Products Europe HAPE works, Spain Hitachi Air Conditioning Products Europe (HAPE works, Spain) has acquired International Standard Quality Management System ISO9001 & ISO authorisation. HAPE performs thorough product quality control using various environmental tests. Hitachi Set Free Series Indoor units and panels are manufactured according to this ISO certification system. Hitachi Air Conditioning Systems Co., Ltd. (Shimizu works, Japan) has acquired International Standard Quality Management System ISO9001 and ISO14001 authorisation. Shimizu works perform thorough product quality control using various environmental tests, severe heating testing for compressors, and many others. Hitachi Set Free Series Outdoor units are manufactured according to this ISO certification system. Hitachi Air Conditioning Products (M) Sdn.Bhd (HAPM works, Malaysia) has acquired International Standard Quality Management System ISO9001 and ISO14001 authorisation. HAPM perform thorough product quality control using various environmental tests. Hitachi Set Free Series RPK Indoor units are manufactured according to this ISO certification system. Company profile Hitachi Air Conditioning Systems Co., Ltd. Shimizu works, Japan Quality control HITACHI in Japanese the name means sunrise is at the forefront of research and development turning new ideas and innovations into new products. Of its $81.4 billion sales worldwide in 2003, close to 5.2% was invested in research and development programs. This vast amount of money has given HITACHI the opportunity to conceive many world firsts examples of which include the technologically advanced and acclaimed scroll and semi-hermetic Screw compressors. These have been incorporated in HITACHI s air conditioning systems and water chillers which have revolutionised air conditioning supported in turn by on-going technical support from HITACHI. From the initial product concept at HITACHI s research and development facility in Japan, product development is dedicated to providing the products the customer requires. Product design and development is continuous with priority being given to the use of ecologically friendly refrigerants. To satisfy your cooling and heating requirements and to ensure the optimum indoor environment, consider HITACHI the first and last word in air conditioning. Hitachi Air Conditioning Products (M) HAPM works, Malaysia 5
4 Indoor Units Utopia Split Systems In-the-Ceiling Capacity Range [HP] Way Cassette 2-Way Cassette Mini Wall Wall Ceiling Floor-Standing Floor-Concealed DC Inverter Utopia Outdoor Units Capacity Range [HP] Adjustable by dip switch setting RAS-HVRNE Series Utopia G8 Outdoor Units Capacity Range [HP] Hitachi s new range of Utopia Split Systems has developed significantly in recent years following a great deal of investment in research and development and testing facilities at various Hitachi factories and laboratories, around the world. Hitachi has continuously developed sophisticated energy saving air conditioning systems that reduce CO 2 emissions and help to protect the global environment. The latest addition to the Utopia range of air conditioning systems is the new G8 series outdoor unit with its combination of SYSTEM FREE indoor units. This combination allows the interconnection of the same indoor units in all the systems. The system provides effortless selection, easy control, logical zooming, and trouble-free installation. Through its modularity the system delivers maximum flexibility and consequently offers increased benefits for both installers and end users. The Hitachi range of Utopia Split Systems benefit from a vast array of significant features all designed with the user in mind! Remarkably low sound levels Improved efficiency due to DC Fan Motor Simple and Flexible Installation Highest Air Quality Space Saving Designs Easy Servicing and Commissioning RAS-AG8E RAS-HG8E RASC-HG8E Econofresh Capacity Range [HP] EF-5GE 7
5 High Efficiency Scroll Compressor EER (Cooling) COP (Heating) Performance is greatly improved by the high-efficiency, high pressure, inverter driven scroll compressor. Reliability greatly improved by optimised bearing Intake loss and leakage loss largely reduced by asymmetric scroll lap Heat loss largely reduced by oil return structure Accurate oiling to the compressor by improved oiling system Rotor shape optimized Peculiar electromagnetic noise to DC compressor cut Compressor rotor Neodymium magnet used Efficiency increased across entire range of rpm used High-efficiency motor [ C] ,000 DC motor AC motor rpm 4,000 6, HP 4HP 5HP R407C Fix speed HVRN (R410A Inverter) HP 4HP 5HP G8 (R407C Fix speed) HVRN (R410A Inverter) Supercooling circuit Performance improved by high-efficiency plate type of heat exchanger Effect of subcooler DC Compressor By using DC, the performance is improved at around 30-40Hz where the operation time of the inverter compressor is longest. Also, to suppress electromagnetic noise interference and achieve low noise, the rotor has been divided into two and the electric pole displaced. Standard R407C Fix Speed and Hitachi R410A Inverter Refrigerating ability increased by supercooling circuit Features and benefits DC Inverter System Free Indoor Units The complete Utopia outdoor unit range can be connected to any of the Hitachi range of indoor units. Compact and Light design Extremely compact design enabling easy installation and effective use of plant space. Hitachi has created one of the lightest and most compact systems on the market. Flexible Installation Piping connectors pivot four ways (front, rear, lateral and down) to allow easier positioning of units. This greatly enhanced flexibility reduces problems during installation and encourages the alignment of multiple outdoor units in small areas. New R410A Refrigerant Using new R410A refrigerant adds the following benefits: Reduced power consumption Increased system performance Higher heat exchange coefficient Reduction in component size. Low sound Levels Super high stream fan, delta shaped edges reduces fan size and noise levels. Bell Mouth, the new bellmouth minimises friction, resulting in smooth flow and sound. 9
6 Twin with UTOPIA G8 series outdoor unit TOPIA G8 series outdoor unit Combination Flexibility The systems are offered in the following combinations: Quad with UTOPIA Big Non visible installation With its modular design the new Utopia G8 series outdoor unit provides a totally flexible air conditioning solution. This offers not only standard cooling functions but, in addition, heating (for heat pump models), dry and fan operation for all environments. Single, Twin or Triple with the Utopia range of outdoor units Single, Twin, Triple and Quad with the Utopia Big outdoor unit Single with Centrifugal Utopia unit The Utopia Centrifugal unit can be installed indoors or outdoors making it the ideal choice for places where it is is forbidden or impossible to place an outdoor unit outside the building. Avoids legislation and local regulations regarding outdoor unit installation. Twin with Utopia G8 series Outdoor unit Quad with UTOPIA Big TOPIA G8 series outdoor unit Single with Centrifugal Utopia Unit Single with UTOPIA G8 series outdoor unit Twin with UTOPIA G8 series outdoor unit Twin with UTOPIA Big Single with Centrifugal UTOPIA Unit Single with Centrifugal Utopia Unit Features and benefits Utopia G8 ad with UTOPIA Big Space Saving Design A sensibly located front access panel allows installation in a space saving in line configuration with as little as 50mm separation between each unit. This is an advantage over conventional side access units that must be positioned several feet apart. Flexible Installation Piping connectors pivot four ways (front, rear, lateral and down) to allow easier positioning of units. This greatly enhanced flexibility reduces problems during installation and encourages the alignment of multiple outdoor units in small areas. H-Link Control System The system requires only two transmission wires for connecting each outdoor unit to its indoor units (to control up to 16 refrigerant cycles). Both outdoor units and indoor units require connecting wires in series. The advantages of using this system are: Outdoor Unit Transmission Wires Refrigerant Piping Trouble-free and adaptable installation No polarity requirements CS Net connection via indoor or outdoor unit Up to 128 indoor units Indoor Unit Indoor Units System Free Indoor Units ith Centrifugal Up to Utopia cable run Unit length: 1000m CS-NET The complete Utopia outdoor unit range can be connected to any of the Hitachi range of indoor units. 11
7 DC Inverter RPI Technical Description Slim, space saving design Adjustable fan speed Adjustable static pressure Drain Pump as standard Air Filter as standard Broader range of external static pressure up to 150 Pa. Flexibly supports a wide range of installation conditions at site, e.g. longer ducts. Increased flexibility and extended ducting now available, provides full temperature control even to remote areas. Adjustable air flow and fan speed control. Wide selection Full line-up from model 0.8HP to 6.0HP. Econofresh Kit As part of the Set Free range the Econofresh can provide up to 100% fresh air and has the ability to provide free cooling via dampers when the outdoor ambient temperature is below the temperature required indoors. Available for 5.0HP unit. In the ceiling In the ceiling ducted systems Slimmest design in the industry Less than 197mm in height, this unit can be fitted practically any existing false ceiling or formerly ducted space, without substantial modification. 120mm 197mm Minimum 5mm False Ceiling (0.8 ~ 1.5HP) Drain-up mechanism Drain-up mechanism is built in the units as standard. An electronic sensor monitors the water level and automatically activates the pump when draining becomes necessary. Return Air ( HP) Available as bottom or rear entry. Suction filter equipped as standard New RPI unit is equipped with a filter as standard. Model Combined Indoor Unit Model Outer Dimensions EF-5GE RPI-5FSN(E) Height mm 254 Width mm Depth mm 270 Net Weight Kg 12.5 Damper Motor Quality 1 Approx. Packing Measurement m Standard Accessories Fresh Outdoor Air Inlet Thermistor Model RPI 1.5FSNE RPI 2.0FSNE RPI 2.5FSNE RPI 3.0FSNE RPI 4.0FSNE RPI 5.0FSNE RPI 6.0FSNE Indoor Unit Configuration Twin Twin Triple Twin Single Twin Single Single Single Power Supply V/Ph/Hz V/50Hz V/50Hz Nominal Cooling Capacity kw 7.1(3.9~8.0) 10(4.9~11.2) 14(TBC) 12.5 (6.7~14) 7.1 (3.9~10.0) 14(TBC) 10 (4.9~11.2) 12.5 (6.7~14) 14 Nominal Heating Capacity kw 8(4~10.0) 11.2(5.7~14.0) 16(TBC) 14(7~18) 8.0 (4.0~10.0) 16 (TBC) 11.2 (5.7~14) 14.0(7~18) 16(TBC) Sound Pressure Levels db(a) 38/37/35 39/37/34 40/38/35 40/38/35 42/41/37 45/44/43 46/45/44 Static Pressure (Hi/Me/Lo) mmaq 5/5/5 8/6/5 8/6/5 8/6/5 8/7/6 8/7/6 8/7/6 Dimensions (HxWxD) mm 197/1020/ /1074/ /1074/ /1074/ /1464/ /1464/ /1464/643 Net Weight Indoor unit kg Air Flow Rate (Hi/Me/Lo) m 3 /min 10/9/7 16/14/12 19/17/15 22/20/17 30/29/26 35/32/29 36/33/31 Approx packing measurement Unit m Combined Outdoor Unit Heat Pump RAS 3.0HVRNE RAS 4.0HVRNE RAS 6.0HRNE RAS 5.0HVRNE RAS 3.0HVRNE RAS 6.0HRNE RAS 4.0HVRNE RAS 5.0HVRNE RAS 6.0HRNE Total Input power cooling kw Total Input power heating kw Energy Efficiency Class Cooling/Heating A/A A/A A/A A/A A/A A/A Sound Pressure Levels db(a) 43(39) 45(41) 48(44) 47(43) 43(39) 48(44) 45(41) 47(43) 48(44) Air Flow Rate (Hi/Me/Lo) m 3 /min Dimensions (HxWxD) mm 800/850/ /950/ /950/ /950/ /850/ /950/ /950/ /950/ /950/315 Net Weight kg Refrigerant type R410A R410A Refrigerant charge kg Precharged Length m Liquid line inches Ø9.53(3/8) Ø9.53(3/8) Ø9.53(3/8) Ø9.53(3/8) Ø9.53(3/8) Ø9.53(3/8) Ø9.53(3/8) Ø9.53(3/8) Ø9.53(3/8) Gas line inches Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Power supply V/Ph/Hz 220/240V 1Ø 380/415 3Ø 220/240V 1Ø 380/415 3Ø Working Range C Cooling Operation: -5 c/43 c DB Heating Operation: -8 c/15.5 c WB Cooling Operation: -5 c/43 c DB Heating Operation: -8 c/15.5 c WB Approximate packing measurement m
8 DC Inverter RCI Technical Description High Efficiency Inside of ceiling NOTES For setting 3 and 2 directions, the separately sold 3-way outlet parts set is necessary. Speed up (1) and Speed-up (2) can be selected through RCS by using C5 option. Silent Operation Slim Air Panel Drain Pump as standard New design air panel DC Motor Efficiency increased by 40% (motor input halved) AC Motor The air panel was revised to give a fresh and simple design. Prevention of smudging and short-circuiting is also taken into account. Motor Efficiency (%) Revolutions per Min. (rpm) 298mm False ceiling Indoor unit body 3HP Air panel High ceiling adaptability satisfies a wide variety of requirements This model is adaptable to a high ceiling with a height of 4.2m by using speed-up taps. These features allow comfortable air conditioning in high street stores. Wireless controller (option) See page 47. Fresh air intake Connection of fresh air intake can be taken in by connecting the duct beside the indoor unit. The control duct fan will operate only when unit is operating giving good air recirculation and comfort. Branch duct Available across the range for added flexibility 4-way cassette 4 way cassette systems Extremely Quite Operation Uses a blade design resulting in an exceptionally quiet fan. HI-stream fan achieves the lowest level of noise, 28 db (A) (RCI-1.0FSN1E). Compact, low height units The height of the units is just 298mm so they can easily be installed in a small space. The units require limited ceiling space which enables improved work efficiency in installation behind the ceiling. High Ceiling 1.0/1.5/2.0/2.5 HP 3.0/3.5/4.0/5.0/6.0 HP (m) 4-way 3-way 2-way 4-way 3-way 2-way Standard Speed-up (1) Speed-up (2) DC Fan Motor with Outstanding Efficiency The DC fan motor greatly improves efficiency compared with conventional products having an AC motor. Also, air blasts are reduced by controlling the rotation speed of the fan. Drain-up mechanism is equipped as standard. Anti-mould filter is equipped as standard. Model RCI 1.5FSN1E RCI 2.0FSN1E RCI 2.5FSN1E RCI 3.0FSN1E RCI 4.0FSN1E RCI 5.0FSN1E RCI 6.0FSN1E Indoor Unit Configuration Twin Twin Triple Twin Single Twin Single Single Single Compatible Panel PG23WA2 PG23WA2 Power Supply V/Ph/Hz V/50Hz V/50Hz Nominal Cooling Capacity kw 7.1(3.9~8.0) 10(4.9~11.2) 14(TBC) 12.5 (6.7~14) 7.1 (3.9~10.0) 14(TBC) 10 (4.9~11.2) 12.5 (6.7~14) 14(TBC) Nominal Heating Capacity kw 8(4~10.0) 11.2(5.7~14.0) 16(TBC) 14(7~18) 8.0 (4.0~10.0) 16 (TBC) 11.2 (5.7~14) 14.0(7~18) 16(TBC) Sound Pressure Levels db(a) 32/30/28 32/30/28 32/30/28 34/32/30 38/35/33 39/37/35 42/40/36 Dimensions (HxWxD) mm 248/840/ /840/ /840/ /840/ /840/ /840/ /840/840 Net Weight Indoor unit kg Air Flow Rate (Hi/Me/Lo) m 3 /min 15/14/12 16/14/12 20/17/15 26/23/20 32/28/24 34/29/25 37/32/27 Approx packing measurement Unit m Combined Outdoor Unit Heat Pump RAS 3.0HVRNE RAS 4.0HVRNE RAS 6.0HRNE RAS 5.0HVRNE RAS 3.0HVRNE RAS 6.0HRNE RAS 4.0HVRNE RAS 5.0HVRNE RAS 6.0HRNE Total Input power cooling kw Total Input power heating kw Energy Efficiency Class Cooling/Heating A/A A/A A/A A/A A/A A/A Sound Pressure Levels db(a) 43/(39) 45(41) 48(44) 47(43) 43(39) 48(44) 45(41) 47(43) 48(44) Air Flow Rate (Hi/Me/Lo) m 3 /min Dimensions (HxWxD) mm 800/850/ /950/ /950/ /950/ /850/ /950/ /950/ /950/ /950/315 Net Weight kg Refrigerant type R410A R410A Refrigerant charge kg Precharged Length (m) m Liquid line inches Ø9.53(3/8) Ø9.53(3/8) Ø9.53(3/8) Ø9.53(3/8) Ø9.53(3/8) Ø9.53(3/8) Ø9.53(3/8) Ø9.53(3/8) Ø9.53(3/8) Gas line inches Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Power supply V/Ph/Hz 220/240V 1Ø 380/415 3 Ø 220/240V 1Ø 380/415 3 Ø Working Range C Cooling Operation: -5 c/43 c DB Heating Operation: -8 c/15.5 c WB Cooling Operation: -5 c/43 c DB Heating Operation: -8 c/15.5 c WB Approximate packing measurement m
9 DC Inverter RCD Technical Description Quiet Operation Slim line design New Air panel, perfect fit for any ceiling Quiet operation and low height design for any ceiling. Reduced weight and size simplify handling for easier renewal. The length of the 3HP type is reduced from 1,320mm to 860mm, the height is also reduced and the volume is decreased by about 50%. The reduced weight of 30kg also makes handling much easier. Inside of Ceiling Ceiling Compact Turbo Fan 298mm 2-way cassette 2 way cassette systems 398mm 298mm 860mm 1,320mm New Model (50%) Current Model (100%) Low-profile design allows installation in a small space inside of ceiling. A compact turbo fan simplifies the structure and reduces the height to 298mm, for easy installation. Top-class noise control due to compact turbo fan. The three-dimensional twisted wings of the compact turbo fan greatly reduce noise and electromagnetic disturbance is minimised by PWM (Pulse Width Modulation) control. Simple Maintenance Auto-louvers are not flocked, therefore the unit does not accumulate dirt and is easy to clean. Speed-up tap ensures comfortable air conditioning even when installed in high ceiling areas. Even rooms with a high ceiling can be comfortably air-conditioned by setting the speed-up tap with the remote control switch. Model RCD 1.5FSN RCD 2.0FSN RCD 2.5FSN RCD 3.0FSN RCD 4.0FSN RCD 5.0FSN Indoor Unit Configuration Twin Twin Triple Twin Single Twin Single Single Compatible Panel PG23DWA1 PG46DWA1 Power Supply V/Ph/Hz V/50Hz V/50Hz Nominal Cooling Capacity kw 7.1(3.9~8.0) 10(4.9~11.2) 14(TBC) 12.5 (6.7~14) 7.1 (3.9~10.0) 14(TBC) 10 (4.9~11.2) 12.5 (6.7~14) Nominal Heating Capacity kw 8(4~10.0) 11.2(5.7~14.0) 16(TBC) 14(7~18) 8.0 (4.0~10.0) 16 (TBC) 11.2 (5.7~14) 14.0(7~18) Sound Pressure Levels db(a) 35/32/30 35/32/30 38/34/31 40/36/33 40/36/33 43/40/36 Dimensions (HxWxD) mm 298/860/ /860/ /860/ /860/ /1420/ /1420/620 Net Weight Indoor unit kg Air Flow Rate (Hi/Me/Lo) m 3 /min 12/10/8.5 15/13/11 18/15.5/ /19/16 30/26/23 32/29/25 Approx packing measurement Unit m Combined Outdoor Unit Heat Pump RAS 3.0HVRNE RAS 4.0HVRNE RAS 6.0HRNE RAS 5.0HVRNE RAS 3.0HVRNE RAS 6.0HRNE RAS 4.0HVRNE RAS 5.0HVRNE Total Input power cooling kw Total Input power heating kw Energy Efficiency Class Cooling/Heating A/A A/A A/A A/A A/A A/A Sound Pressure Levels db(a) 43/(39) 45(41) 48(44) 47(43) 43/(39) 48(44) 45(41) 47(43) Air Flow Rate (Hi/Me/Lo) m 3 /min Dimensions (HxWxD) mm 800/850/ /950/ /950/ /950/ /850/ /950/ /950/ /950/315 Net Weight kg Refrigerant type R410A R410A Refrigerant charge kg Precharged Length m Liquid line inches Ø9.53(3/8) Ø9.53(3/8) Ø9.53(3/8) Ø9.53(3/8) Ø9.53(3/8) Ø9.53(3/8) Ø9.53(3/8) Ø9.53(3/8) Gas line inches Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Power supply V/Ph/Hz 220/240V 1Ø 380/415 3 Ø 220/240V 1Ø 380/415 3 Ø Working Range C Cooling Operation: -5 c/43 c DB Heating Operation: -8 c/15.5 c WB Cooling Operation: -5 c/43 c DB Heating Operation: -8 c/15.5 c WB Approximate packing measurement m
10 FSNM Wall mounted DC Inverter RPK Technical Description Extended Line-up NEW Quiet operation More compact than previous models FSN1M Mini Wall mounted New design Ideal for the home Compact and stylish Wall mounted Wall mounted systems Wall Mounted Compact, allowing easy installation Designed with ease of installation in mind this new space saving model uses a high proportion of light weight parts reducing the unit weight to 12kg. Expanded product line up 2.5/3.0/4.0HP models available Compact design It s compact size allows easy installation and the weight has been reduced by 15%. Quiet Operation Trapezoidal blades cut the air diagonally to reduce air flow resistance. The conical blade fan ensures a high air flow and low noise with slow rotation. This model creates a pleasant, quiet and comfortable environment. Swing Louver The Swing Louver with 3 flaps at both sides has been adopted, in order to provide comfortable air to the entire room. Wireless or Wired Control The indoor unit is equipped with a wireless receiver kit inside as an standard accessory. The wired remote control switch, PC-P1HE is also applicable. Mini Wall Mounted Compact and Stylish Design This model has been designed with a flat panel and the width has been reduced by 250mm to 780mm. The weight has also been condensed by approximately 17%. Ideal for the Home This model creates a pleasant, quiet and comfortable environment, making it the ideal choice for the home. Wireless or Wired Control The indoor unit is equipped with a wireless receiver kit (PC-LH3A) inside as a standard accessory. The wired remote control switch, PC-P1HE is also applicable. Easy Maintenance Alarm indication when using PC-LH3A has been improved (LED of the unit shows alarm code). Quiet Operation Trapezoidal blades cut the air diagonally reducing air flow resistance. Conical blade fans with their slow rotation ensure a high air flow and low noise levels. Model RPK 1.5FSNM RPK 1.5FSN1M RPK 2.0FSNM RPK 2.5FSNM RPK 3.0FSNM RPK 4.0FSNM Indoor Unit Configuration Twin Quad Twin Quad Twin Triple Twin Single Twin Single Power Supply V/Ph/Hz V/50Hz V/50Hz Nominal Cooling Capacity kw 7.1(3.9~8) (4.9~11.2) 14(TBC) 12.5 (6.7~14.0) 7.1(3.9~8) 14(TBC) 10.0(4.9~11.2) Nominal Heating Capacity kw 8.0(4.0~10.0) (5.7~14.0) 16(TBC) 14(7~18) 8.0(4.0~10.0) 16(TBC) 11.2(5.7~14.0) Sound Pressure Levels db(a) 39/37/34 40/38/36 40/38/36 43/40/37 43/40/37 49/46/43 Dimensions (HxWxD) mm 295/1030/ /780/ /1030/ /1390/ /1390/ /1390/225 Net Weight kg Air Flow Rate (Hi/Me/Lo) m 3 /min 13/11/9 11/10/9 14/12/10 22/18/15 22/18/15 26/22/19 Approx packing measurement Unit m Combined Outdoor Unit Heat Pump RAS 3.0HVRNE RAS 6.0HRNE RAS 3.0HVRNE RAS 6.0HRNE RAS 4.0HVRNE RAS 6.0HRNE RAS 5.0HVRNE RAS 3.0HVRNE RAS 6.0HRNE RAS 4.0HVRNE Total Input power cooling kw Total Input power heating kw Energy Efficiency Class Cooling/Heating A/A A/A A/A A/A A/A A/A Sound Pressure Levels db(a) 43/(39) 48(44) 43/(39) 48(44) 45(41) 48(44) 47(43) 43(39) 48(44) 45(41) Air Flow Rate (Hi/Me/Lo) m 3 /min Dimensions (HxWxD) mm 800/850/ /950/ /850/ /950/ /950/ /950/ /950/ /850/ /950/ /950/315 Net Weight kg Refrigerant type R410A R410A Refrigerant charge kg Precharged Length m Liquid line inches Ø9.53(3/8) Ø9.53(3/8) Ø9.53(3/8) Ø9.53(3/8) Ø9.53(3/8) Ø9.53(3/8) Ø9.53(3/8) Ø9.53(3/8) Ø9.53(3/8) Gas line inches Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Power supply V/Ph/Hz 220/240V 1Ø 380/415 3Ø 220/240V 1Ø 380/415 3Ø Working Range C Cooling Operation: -5 c/43 c DB Heating Operation: -8 c/15.5 c WB Cooling Operation: -5 c/43 c DB Heating Operation: -8 c/15.5 c WB Approximate packing measurement m
11 DC Inverter RPC Technical Description Stylish design Space saving design Easy installation Quiet Operation Quiet operation, easy installation and space saving design Versatile mounting To expand installation and positioning options, HITACHI has added a second drain pipe connector, one more than conventional units. Refrigeration pipes have also been improved and can now be connected at the left, right or rear of the unit. Rear Side Quiet Operation The ceiling unit is equipped with a highly efficient, multi-blade centrifugal fan that generates a powerful yet gentle airflow throughout the room. A redesigned aerodynamically tested air panel minimises operational sound even at high fan speeds. Easier installation By enabling refrigeration piping to be tucked-in close to each indoor unit, piping layout and installation have been made much easier. Anti-mildew filter Anti-mildew filter is equipped as a standard accessory. Ceiling suspended Ceiling suspended systems Open Space 163mm Concealed 150mm (2,0, 2,5 and 3,0 HP) Drain piping Space saving design Hitachi s unique feature An innovative fan and heat exchanger design led to the creation of today s ultra-slim ceiling unit. Fully adjustable mounting brackets permit close fitting to the ceiling to make installation possible in even the smallest area. Less than 163mm of vertical space are required for installation. Model RPC 2.0FSNE RPC 2.5FSNE RPC 3.0FSNE RPC 4.0FSNE RPC 5.0FSNE RPC 6.0FSNE Indoor Unit Configuration Twin Triple Twin Single Twin Single Single Single Power Supply V/Ph/Hz V/50Hz V/50Hz Nominal Cooling Capacity kw 10.0 (4.9~11.2) 14(TBC) 12.5 (6.7~14.0) 7.1(3.9~8) 14(TBC) 10.0(4.9~11.2) 12.5 (6.7~14.0) 14 (TBC) Nominal Heating Capacity kw 11.2 (5.7~14.0) 16(TBC) 14(7~18) 8.0(4.0~10.0) 16(TBC) 11.2(5.7~14.0) 11.2 (7~18) 16 (TBC) Sound Pressure Levels db(a) 44/42/38 46/43/41 48/45/42 49/45/39 49/46/41 50/48/44 Dimensions (HxWxD) mm 163/1094/ /1314/ /1314/ /1314/ /1574/ /1574/625 Net Weight Indoor unit kg Air Flow Rate (Hi/Me/Lo) m 3 /min 15/13/10 18/16/12 21/17/15 30/24/19 35/28/21 37/32/27 Approx packing measurement Unit m Combined Outdoor Unit Heat Pump RAS 4.0HVRNE RAS 6.0HRNE RAS 5.0HVRNE RAS 3.0HVRNE RAS 6.0HRNE RAS 4.0HVRNE RAS 5.0HVRNE RAS 6.0HRNE Total Input power cooling kw Total Input power heating kw Energy Effciency Class Cooling/Heating A/A A/A A/A A/A A/A Sound Pressure Levels db(a) 45(41) 48(44) 47(43) 43(39) 48(44) 45(41) 47(43) 48(44) Air Flow Rate (Hi/Me/Lo) m 3 /min Dimensions (HxWxD) mm 1240/950/ /950/ /950/ /850/ /950/ /950/ /950/ /950/315 Net Weight kg Refrigerant type R410A R410A Refrigerant charge kg Precharged Length m Liquid line inches Ø9.53(3/8) Ø9.53(3/8) Ø9.53(3/8) Ø9.53(3/8) Ø9.53(3/8) Ø9.53(3/8) Ø9.53(3/8) Ø9.53(3/8) Gas line inches Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Power supply V/Ph/Hz 220/240V 1Ø 380/415 3 Ø 220/240V 1Ø 380/415 3 Ø Working Range C Cooling Operation: -5 c/43 c DB Heating Operation: -8 c/ 15.5 c WB Cooling Operation: -5 c/43 c DB Heating Operation: -8 c/ 15.5 c WB Approximate packing measurement m
12 DC Inverter RPF/RPFI Technical Description Floor mounted indoor units RPF Floor Type Slim design, only 200mm deep Low height, only 630mm Light unit Low sound level Floor concealed indoor units RPFI Compact design 620mm in height 220mm in depth Space-saving slim unit, only 220mm in depth Slim line design only 220mm in depth allowing the unit to be installed without spoiling the style or beauty of the room. Effective use of space by window With a height of 630mm, may be installed by a window leaving plenty of window space. Best installed in a perimeter zone. Low height Only 630mm. Concealed Floor Mounted Compact design for limited space inside of perimeter wall. So compact that it fits into even the smallest space. Special emphasis placed on interior design compatibility as well as space saving design, allowing it to fit perfectly into the space below a bay window. Optional location for remote control switch Install the PC-P1HE under the plastic cover Floor Mounted Floor mounted systems uncased Model RPFI 1.5FSNE RPFI 2.0FSNE RPFI 2.5FSNE Indoor Unit Configuration Twin Twin Triple Twin Power Supply V/Ph/Hz V/50Hz Nominal Cooling Capacity kw 7.1(3.9~8.0) 10.0 (4.9~11.2) 14(TBC) 12.5 (6.7~14.0) Nominal Heating Capacity kw 8.0(4.0~10.0) 11.2 (5.7~14.0) 16(TBC) 14(7~18) Sound Pressure Levels db(a) 38/35/31 39/36/32 42/38/34 Dimensions (HxWxD) mm 620/988/ /1238/ /1238/220 Net Weight Indoor unit kg Air Flow Rate (Hi/Me/Lo) m 3 /min 12/10/9 16/14/11 16/14/11 Approx packing measurement Unit m Floor mounted systems cased Model RPF 1.5FSNE RPF 2.0FSNE RPF 2.5FSNE Indoor Unit Configuration Twin Twin Triple Twin Power Supply V/Ph/Hz V/50Hz Nominal Cooling Capacity kw 7.1(3.9~8.0) 10.0 (4.9~11.2) 14(TBC) 12.5 (6.7~14.0) Nominal Heating Capacity kw 8.0(4.0~10.0) 11.2 (5.7~14.0) 16(TBC) 14(7~18) Sound Pressure Levels db(a) 38/35/31 39/36/32 42/38/34 Dimensions (HxWxD) mm 630/1170/ /1420/ /1420/220 Net Weight Indoor unit kg Air Flow Rate (Hi/Me/Lo) m 3 /min 12/10/9 16/14/11 16/14/11 Approximate packing measurement m Combined Outdoor Unit RAS 3.0HVRNE RAS 4.0HVRNE RAS 6.0HRNE RAS 5.0HVRNE Total Input power cooling kw Total Input power heating kw Energy Efficiency Class Cooling/Heating A/A A/A A/A Sound Pressure Levels db(a) 43/(39) 45(41) 48(44) 47(43) Air Flow Rate (Hi/Me/Lo) m 3 /min Dimensions (HxWxD) mm 800/850/ /950/ /950/ /950/315 Net Weight kg Refrigerant type R410A Refrigerant charge kg Precharged Length m 30 Liquid line inches Ø9.53(3/8) Ø9.53(3/8) Ø9.53(3/8) Ø9.53(3/8) Gas line inches Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Power supply V/Ph/Hz 220/240V 1Ø 380/415 3 Ø Working Range C Cooling Operation: -5 c/43 c DB Heating Operation: -8 c/ 15.5 c WB Approximate packing measurement m Combined Outdoor Unit RAS 3.0HVRNE RAS 4.0HVRNE RAS 6.0HRNE RAS 5.0HVRNE Total Input power cooling kw Total Input power heating kw Energy Efficiency Class Cooling/Heating A/A A/A A/A Sound Pressure Levels db(a) 43/(39) 45(41) 48(44) 47(43) Air Flow Rate (Hi/Me/Lo) m 3 /min Dimensions (HxWxD) mm 800/850/ /950/ /950/ /950/315 Net Weight kg Refrigerant type R410A Refrigerant charge kg Precharged Length m 30 Liquid line inches Ø9.53(3/8) Ø9.53(3/8) Ø9.53(3/8) Ø9.53(3/8) Gas line inches Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Power supply V/Ph/Hz 220/240V 1Ø 380/415 3Ø Working Range C Cooling Operation: -5 c/43 c DB Heating Operation: -8 c/15.5 c WB Approximate packing measurement m
13 Utopia G8 RPI Technical Description Slim, space saving design Adjustable fan speed Adjustable static pressure Drain Pump as standard Air Filter as standard Slimmest design in the industry Less than 197mm in height, this unit can be fitted practically any existing false ceiling or formerly ducted space, without substantial modification. Minimum 5mm Broader range of external static pressure up to 150 Pa. Flexibly supports a wide range of installation conditions at site, e.g. longer ducts. Increased flexibility and extended ducting now available, provides full temperature control even to remote areas. Adjustable air flow and fan speed control. Wide selection Full line-up from model 0.8HP to 6.0HP. Drain-up mechanism 197mm Drain-up mechanism is built in the units as standard. An electronic sensor monitors the water level and automatically activates the pump when draining becomes necessary. In the ceiling 120mm False Ceiling (0.8 ~ 1.5HP) Return Air ( HP) Available as bottom or rear entry. Suction filter equipped as standard New RPI unit is equipped with a filter as standard. In the ceiling ducted systems Model RPI 1.5FSNE RPI 2.0FSNE RPI 2.5FSNE RPI 2.5FSNE RPI 3.0FSNE RPI 3.5FSNE RPI 4.0FSNE Indoor Unit Configuration Twin Quad Single Twin Triple Quad Single Twin Single Twin Single Single Twin Power Supply V/Ph/Hz V/50Hz V/50Hz Nominal Cooling Capacity kw Nominal Heating Capacity kw Sound Pressure Levels check LSP db(a) 38/37/35 39/37/34 40/38/35 40/38/35 40/38/35 40/38/35 42/41/37 Static Pressure (Hi/Me/Lo) mmaq 5/5/5 8/6/5 8/6/5 8/6/5 8/6/5 8/6/5 8/7/6 Dimensions (HxWxD) mm 197/1020/ /1074/ /1074/ /1074/ /1074/ /1074/ /1464/643 Net Weight Indoor unit kg Air Flow Rate (Hi/Me/Lo) m 3 /min 10/9/7 16/14/12 19/17/15 19/17/15 22/20/17 22/20/17 30/29/26 Approx. Packing Measurement m Cooling Only RAS 3.0AG(V)8E RAS 6.0AG8E RAS 2.0AGV8E RAS 4.0AG(V)8E RAS 6.0AG8E RAS 8.0AG8E RAS 2.5AG(V)8E RAS 5.0AG8E RAS 3.0AG(V)8E RAS 6.0AG8E RAS 3.5AG(V)8E RAS 4.0AG(V)8E RAS 8.0AG8E Combined Outdoor Unit Heat Pump RAS 3.0HG8E RAS 6.0HG8E RAS 2.0HGV8E RAS 4.0HG8E RAS 6.0HG8E RAS 8.0HG8E RAS 2.5HG8E RAS 5.0HG8E RAS 3.0HG8E RAS 6.0HG8E RAS 3.5HG8E RAS 4.0HG8E RAS 8.0HG8E Total Input Power Cooling kw Total Input Power Heating kw Sound Pressure Levels db(a) Air Flow Rate m 3 /min Dimensions (HxWxD) mm 800/850/ /850/ /850/ /850/ /850/ /1000/ /850/ /850/ /850/ /850/ /850/ /850/ /1000/875 Net Weight kg Refrigerant type R407C R407C Refrigerant charge kg ? ? Precharged Length m 10 metres 10 metres Liquid line inches 9.53(3/8) 9.53(3/8) 6.35(1/4) 9.53(3/8) 9.53(3/8) Ø12.7(1/2) 9.53(3/8) 9.53(3/8) 9.53(3/8) 9.53(3/8) 9.53(3/8) 9.53(3/8) Ø12.7(1/2) Gas line inches 15.88(5/8) 19.05(3/4) 15.88(5/8) 19.05(3/4) 19.05(3/4) Ø28.6(1 1/8) 15.88(5/8) 19.05(3/4) 15.88(5/8) 19.05(3/4) 15.88(5/8) 19.05(3/4) Ø28.6(1 1/8) Power supply V/Ph/Hz 220/240V 1Ø 380/415 3Ø 220/240V 1Ø 380/415 3Ø Working Range C Cooling Operation: -5 c/43 c DB Heating Operation: -8 c/15.5 c WB Cooling Operation: -5 c/43 c DB Heating Operation: -8 c/15.5 c WB Approx. packing measurement m
14 Utopia G8 RPI Technical Description Econofresh Kit As part of the Set Free range the Econofresh can provide up to 100% fresh air and has the ability to provide free cooling via dampers when the outdoor ambient temperature is below the temperature required indoors. Available for 5.0HP unit. In the ceiling Model EF-5GE Combined Indoor Unit Model RPI-5FSN(E) Outer Dimensions Height mm 254 Width mm Depth mm 270 Net Weight Kg 12.5 Damper Motor Quality 1 Approx. Packing Measurement m Standard Accessories Fresh Outdoor Air Inlet Thermistor In the ceiling ducted systems Model RPI 5.0FSNE RPI 6.0FSNE RPI 8FSNE RPI 10FSNE Indoor Unit Configuration Single Twin Single Single Single Power Supply V/Ph/Hz V/50Hz Nominal Cooling Capacity kw Nominal Heating Capacity kw Sound Pressure Levels check LSP db(a) 45/44/43 46/45/44 54/54/51 55/55/52 Static Pressure (Hi/Me/Lo) mmaq 8/7/6 8/7/6 18/18/14 18/18/14 Dimensions (HxWxD) mm 274/1464/ /1464/ /1580/ /1580/600 Net Weight Indoor unit kg Air Flow Rate (Hi/Me/Lo) m 3 /min 35/32/29 36/33/31 66/66/57 75/75/66 Approx. Packing Measurement m Cooling Only RAS 5.0AG8E RAS 10AG8E RAS 6.0AG8E RAS8.0AG8E RAS10AG8E Combined Outdoor Unit Heat Pump RAS 5.0HG8E RAS 10HG8E RAS 6.0HG8E RAS8.0HG8E RAS10HG8E Total Input Power Cooling kw Total Input Power Heating kw Sound Pressure Levels db(a) Air Flow Rate m 3 /min 135 Dimensions (HxWxD) mm 1240/850/ /1000/ /850/ /1000/ /1000/875 Net Weight kg Refrigerant type Refrigerant charge kg 4.5? 4.7?? Precharged Length m Liquid line inches 9.53(3/8) Ø15.88(5/8) 9.53(3/8) Ø12.7(1/2) Ø15.88(5/8) Gas line inches 19.05(3/4) Ø28.6(1 1/8) 19.05(3/4) Ø28.6(1 1/8) Ø28.6(1 1/8) Power supply V/Ph/Hz 220/240V 1Ø 380/415 3Ø Working Range C Cooling Operation: -5 c/43 c DB Heating Operation: -8 c/15.5 c WB Approx. packing measurement m
15 Utopia G8 RCI Technical Description Silent Operation Inside of ceiling NOTES For setting 3 and 2 directions, the separately sold 3-way outlet parts set is necessary. Speed up (1) and Speed-up (2) can be selected through RCS by using C5 option. Slim Air Panel Drain Pump as standard New design air panel DC Motor Efficiency increased by 40% (motor input halved) AC Motor The air panel was revised to give a fresh and simple design. Prevention of smudging and short-circuiting is also taken into account. Motor Efficiency (%) Revolutions per Min. (rpm) 298mm False ceiling Indoor unit body 3HP Air panel High ceiling adaptability satisfies a wide variety of requirements This model is adaptable to a high ceiling with a height of 4.2m by using speed-up taps. These features allow comfortable air conditioning in high street stores. Wireless controller (option) See page 47. Fresh air intake Connection of fresh air intake can be taken in by connecting the duct beside indoor unit. The control duct fan will operate only when unit is operating giving good air recirculation and comfort. Branch duct Available across the range for added flexibility 4-way cassette 4 way cassette systems Extremely Quite Operation Uses a blade design resulting in an exceptionally quiet fan. HI-stream fan achieves the lowest level of noise, 28 db (A) (RCI-1.0FSN1E). Compact, low height units The height of the units is just 298mm so they can easily be installed in a small space. The units require limited ceiling space which enables improved work efficiency in installation behind the ceiling. High Ceiling 1.0/1.5/2.0/2.5 HP 3.0/3.5/4.0/5.0/6.0 HP (m) 4-way 3-way 2-way 4-way 3-way 2-way Standard Speed-up (1) Speed-up (2) DC Fan Motor with Outstanding Efficiency The DC fan motor greatly improves efficiency compared with conventional products having an AC motor. Also, air blasts are reduced by controlling the rotation speed of the fan. Drain-up mechanism is equipped as standard. Anti-mould filter is equipped as standard. Model RCI 1.5FSN1E RCI 2.0FSN1E RCI 2.5FSN1E RCI 3.0FSN1E RCI 3.5FSN1E RCI 4.0FSN1E RCI 5.0FSN1E RCI 6.0FSN1E Indoor Unit Configuration Twin Quad Single Twin Triple Quad Single Twin Quad Single Twin Single Single Twin Single Twin Single Compatible Panel P-G23WA2 P-G23WA2 Power Supply V/Ph/Hz V/50Hz V/50Hz Nominal Cooling Capacity kw Nominal Heating Capacity kw Sound Pressure Levels db(a) 32/30/28 32/30/28 32/30/28 34/32/30 34/32/30 38/35/33 39/37/35 42/40/36 Dimensions (HxWxD) mm 248/840/ /840/ /840/ /840/ /840/ /840/ /840/ /840/840 Net Weight Indoor unit kg Air Flow Rate (Hi/Me/Lo) m 3 /min 15/14/12 16/14/12 20/17/15 26/23/20 26/23/20 32/28/24 34/29/25 37/32/27 Approx. packing measurement m Cooling Only RAS 3.0AG(V)8E RAS 6.0AG8E RAS 2.0AGV8E RAS 4.0AG(V)8E RAS 6.0AG8E RAS 8.0AG8E RAS 2.5AG(V)8E RAS 5.0AG8E RAS 10AG8E RAS 3.0AG(V)8E RAS 6.0AG8E RAS 3.5AG(V)8E RAS 4.0AG(V)8E RAS 8.0AG8E RAS 5.0AG8E RAS 10AG8E RAS 6.0AG8E Combined Outdoor Unit Heat Pump RAS 3.0HG8E RAS 6.0HG8E RAS 2.0HGV8E RAS 4.0HG8E RAS 6.0HG8E RAS 8.0HG8E RAS 2.5HG8E RAS 5.0HG8E RAS 10HG8E RAS 3.0HG8E RAS 6.0HG8E RAS 3.5HG8E RAS 4.0HG8E RAS 8.0HG8E RAS 5.0HG8E RAS 10HG8E RAS 6.0HG8E Total Input power cooling kw Total Input power heating kw Sound Pressure Levels db(a) Air Flow Rate m 3 /min Dimensions (HxWxD) mm 800/850/ /850/ /850/ /850/ /850/ /1000/ /850/ /850/ /1000/ /850/ /850/ /850/ /850/ /1000/ /850/ /1000/ /850/350 Net Weight kg Refrigerant type kg R407C R407C Refrigerant charge Precharged Length m 10m 10m Liquid line inches 9.53(3/8) (1/4) Ø12.7(1/2) Ø15.88(5/8) Ø12.7(1/2) 9.53 Ø15.88(5/8) 9.53 Gas line inches Power supply V/Ph/Hz 220/240V 1Ø 380/415 3Ø 220/240V 1Ø 380/415 3Ø Working Range C Cooling Operation: -5 c/43 c DB Heating Operation: -8 c/ 15.5 c WB Cooling Operation: -5 c/43 c DB Heating Operation: -8 c/ 15.5 c WB Approx. packing measurement m
16 Utopia G8 RCD Technical Description Quiet Operation Slim line design New Air panel, perfect fit for any ceiling Quiet operation and low height design for any ceiling. Reduced weight and size simplify handling for easier renewal. The length of the 3HP type is reduced from 1,320mm to 860mm, the height is also reduced and the volume is decreased by about 50%. The reduced weight of 30kg also makes handling much easier. Inside of Ceiling Ceiling Compact Turbo Fan 298mm 2-way cassette 2 way cassette systems 398mm 298mm 860mm 1,320mm New Model (50%) Current Model (100%) Low-profile design allows installation in a small space inside of ceiling. A compact turbo fan simplifies the structure and reduces the height to 298mm, for easy installation. Top-class noise control due to compact turbo fan. The three-dimensional twisted wings of the compact turbo fan greatly reduce noise and electromagnetic disturbance is minimised by PWM (Pulse Width Modulation) control. Simple Maintenance Auto-louvers are not flocked, therefore the unit does not accumulate dirt and is easy to clean. Speed-up tap ensures comfortable air conditioning even when installed in high ceiling areas. Even rooms with a high ceiling can be comfortably air-conditioned by setting the speed-up tap with the remote control switch. Model RCD 1.5FSN RCD 2.0FSN RCD 2.5FSN RCD 3.0FSN RCD 4.0FSN RCD 5.0FSN Indoor Unit Configuration Twin Quad Single Twin Triple Quad Single Twin Quad Single Twin Single Twin Single Twin Compatible Panel P-G23DWA1 PG46DWA1 Power Supply V/Ph/Hz V/50Hz V/50Hz Nominal Cooling Capacity kw Nominal Heating Capacity kw Sound Pressure Levels db(a) 35/32/30 35/32/30 38/34/31 40/36/33 40/36/33 43/40/36 Dimensions (HxWxD) mm 298/860/ /860/ /860/ /860/ /1420/ /1420/620 Net Weight Indoor unit kg Air Flow Rate (Hi/Me/Lo) m 3 /min 12/10/8.5 15/13/11 18/15.5/ /19/16 30/26/23 32/29/25 Approx. packing measurement m Cooling Only RAS 3.0AG(V)8E RAS 6.0AG8E RAS 2.0AGV8E RAS 4.0AG(V)8E RAS 6.0AG8E RAS 8.0AG8E RAS 2.5AG(V)8E RAS 5.0AG8E RAS 10AG8E RAS 3.0AG(V)8E RAS 6.0AG8E RAS 4.0AG(V)8E RAS 8.0AG8E RAS 5.0AG8E RAS 10AG8E Combined Outdoor Unit Heat Pump RAS 3.0HG8E RAS 6.0HG8E RAS 2.0HGV8E RAS 4.0HG8E RAS 6.0HG8E RAS 8.0HG8E RAS 2.5HG8E RAS 5.0HG8E RAS 10HG8E RAS 3.0HG8E RAS 6.0HG8E RAS 4.0HG8E RAS 8.0HG8E RAS 5.0HG8E RAS 10HG8E Total Input power cooling kw Total Input power heating kw Sound Pressure Levels db(a) Air Flow Rate m 3 /min Dimensions (HxWxD) mm 800/850/ /850/ /850/ /850/ /850/ /1000/ /850/ /850/ /1000/ /850/ /850/ /850/ /1000/ /850/ /1000/875 Net Weight kg Refrigerant type R407C R407C Refrigerant charge kg Precharged Length m 10m 10m Liquid line inches 9.53 (3/8) 9.53(3/8) 6.35(1/4) 9.53(3/8) 9.53(3/8) Ø12.7(1/2) 9.53(3/8) 9.53(3/8) Ø15.88(5/8) 9.53(3/8) 9.53(3/8) 9.53(3/8) Ø12.7(1/2) 9.53(3/8) Ø15.88(5/8) Gas line inches 15.88(5/8) 19.05(3/4) 15.88(5/8) 19.05(3/4) 19.05(3/4) Ø28.6(1 1/8) 15.88(5/8) 19.05(3/4) Ø28.6(1 1/8) 15.88(5/8) 19.05(3/4) 19.05(3/4) Ø28.6(1 1/8) 19.05(3/4) Ø28.6(1 1/8) Power supply V/Ph/Hz 220/240V 1Ø 380/415 3Ø 220/240V 1Ø 380/415 3Ø Working Range C Cooling Operation: -5 c/43 c DB Heating Operation: -8 c/ 15.5 c WB Cooling Operation: -5 c/43 c DB Heating Operation: -8 c/ 15.5 c WB Approx. packing measurement m
17 FSNM Wall mounted Utopia G8 RPK Technical Description Extended Line-up NEW Quiet operation More compact than previous models FSN1M Mini Wall mounted New design Ideal for the home Compact and stylish Wall mounted Wall mounted systems Wall Mounted Compact, allowing easy installation Designed with ease of installation in mind this new space saving model uses a high proportion of light weight parts reducing the unit weight to 12kg. Expanded product line up 2.5/3.0/4.0HP models available Compact design It s compact size allows easy installation and the weight has been reduced by 15%. Quiet Operation Trapezoidal blades cut the air diagonally to reduce air flow resistance. The conical blade fan ensures a high air flow and low noise with slow rotation. This model creates a pleasant, quiet and comfortable environment. Swing Louver The Swing Louver with 3 flaps at both sides has been adopted, in order to provide comfortable air to the entire room. Wireless or Wired Control The indoor unit is equipped with a wireless receiver kit inside as an standard accessory. The wired remote control switch, PC-P1HE is also applicable. Mini Wall Mounted Compact and Stylish Design This model has been designed with a flat panel and the width has been reduced by 250mm to 780mm. The weight has also been condensed by approximately 17%. Ideal for the Home This model creates a pleasant, quiet and comfortable environment, making it the ideal choice for the home. Wireless or Wired Control The indoor unit is equipped with a wireless receiver kit (PC-LH3A) inside as a standard accessory. The wired remote control switch, PC-P1HE is also applicable. Easy Maintenance Alarm indication when using PC-LH3A has been improved (LED of the unit shows alarm code). Quiet Operation Trapezoidal blades cut the air diagonally reducing air flow resistance. Conical blade fans with their slow rotation ensure a high air flow and low noise levels. Model RPK 1.5 FSNM RPK 1.5FSN1M RPK 2.0FSNM RPK 2.0FSNM RPK 2.5FSNM RPK 3.0FSNM RPK 3.5FSNM RPK 4.0FSNM Indoor Unit Configuration Twin Quad Twin Quad Single Twin Triple Quad Single Twin Quad Single Twin Single Twin Power Supply V/Ph/Hz V/50Hz V/50Hz Nominal Cooling Capacity kw Nominal Heating Capacity kw Sound Pressure Levels db(a) 39/37/34 40/38/36 40/38/36 40/38/36 43/40/37 43/40/37 49/46/43 49/46/43 Dimensions (HxWxD) mm 295/1030/ /780/ /1030/ /1030/ /1390/ /1390/ /1390/ /1390/225 Net Weight Indoor unit kg Air Flow Rate (Hi/Me/Lo) m 3 /min 13/11/9 11/10/9 14/12/10 14/12/10 22/18/15 22/18/15 26/24/20 26/22/19 Approximate packing measurement m Cooling Only RAS 3.0AG(V)8E RAS 6.0AG8E RAS 3.0AG(V)8E RAS 6.0AG8E RAS 2.0AGV8E RAS 4.0AG(V)8E RAS 6.0AG8E RAS 8.0AG8E RAS 2.5AG(V)8E RAS 5.0AG8E RAS 10AG8E RAS 3.0AG(V)8E RAS 6.0AG8E RAS 3.5AG(V)8E RAS 8.0AG8E Combined Outdoor Unit Heat Pump RAS 3.0HG8E RAS 6.0HG8E RAS 3.0HG8E RAS 6.0HG8E RAS 2.0HGV8E RAS 4.0HG8E RAS 6.0HG8E RAS 8.0HG8E RAS 2.5HG8E RAS 5.0HG8E RAS 10HG8E RAS 3.0HG8E RAS 6.0HG8E RAS 3.5HG8E RAS 8.0HG8E Total Input power cooling kw Total Input power heating kw Sound Pressure Levels db(a) Air Flow Rate (Hi/Me/Lo) m 3 /min Dimensions (HxWxD) mm 800/850/ /850/ /850/ /850/ /850/ /850/ /850/ /1000/ /850/ /850/ /1000/ /850/ /850/ /850/ /1000/875 Net Weight kg Refrigerant type R407C R407C Refrigerant charge kg Precharged Length m 10m 10m Liquid line inches 9.53 (3/8) 9.53(3/8) 9.53 (3/8) 9.53(3/8) 6.35(1/4) 9.53 (3/8) 9.53 (3/8) Ø12.7(1/2) 9.53 (3/8) 9.53 (3/8) Ø15.88(5/8) 9.53 (3/8) 9.53 (3/8) 9.53 (3/8) Ø12.7(1/2) Gas line inches 15.88(5/8) 19.05(3/4) 15.88(5/8) 19.05(3/4) 15.88(5/8) 19.05(3/4) 19.05(3/4) Ø28.6(1 1/8) 15.88(5/8) 19.05(3/4) Ø28.6(1 1/8) 15.88(5/8) 19.05(3/4) 15.88(5/8) 19.05(3/4) Power supply V/Ph/Hz 220/240V 1Ø 380/415 3Ø 220/240V 1Ø 380/415 3Ø Working Range C Cooling Operation: -5 c/43 c DB Heating Operation: -8 c/ 15.5 c WB Cooling Operation: -5 c/43 c DB Heating Operation: -8 c/ 15.5 c WB Approximate packing measurement m
18 Utopia G8 RPC Technical Description Stylish design Space saving design Easy installation Quiet Operation Quiet operation, easy installation and space saving design Versatile mounting To expand installation and positioning options, HITACHI has added a second drain pipe connector, one more than conventional units. Refrigeration pipes have also been improved and can now be connected at the left, right or rear of the unit. Rear Side Quiet Operation The ceiling unit is equipped with a highly efficient, multi-blade centrifugal fan that generates a powerful yet gentle airflow throughout the room. A redesigned aerodynamically tested air panel minimises operational sound even at high fan speeds. Easier installation By enabling refrigeration piping to be tucked-in close to each indoor unit, piping layout and installation have been made much easier. Anti-mildew filter Anti-mildew filter is equipped as a standard accessory. Ceiling suspended Ceiling suspended systems Open Space 163mm Concealed 150mm (2,0, 2,5 and 3,0 HP) Drain piping Space saving design Hitachi s unique feature An innovative fan and heat exchanger design led to the creation of today s ultra-slim ceiling unit. Fully adjustable mounting brackets permit close fitting to the ceiling to make installation possible in even the smallest area. Less than 163mm of vertical space are required for installation. Model RPC 2.0FSNE RPC 2.5FSNE RPC 3.0FSNE RPC 3.5FSNE RPC 4.0FSNE RPC 5.0FSNE RPC 6.0FSNE Indoor Unit Configuration Single Twin Triple Quad Single Twin Quad Single Single Single Twin Single Twin Single Power Supply V/Ph/Hz V/50Hz V/50Hz Nominal Cooling Capacity kw Nominal Heating Capacity kw Sound Pressure Levels db(a) 44/42/38 46/43/41 48/45/42 48/45/42 49/45/39 49/46/41 50/48/44 Dimensions (HxWxD) mm 163/1094/ /1314/ /1314/ /1314/ /1314/ /1574/ /1574/625 Net Weight Indoor unit kg Air Flow Rate (Hi/Me/Lo) m 3 /min 15/13/10 18/16/12 21/17/15 21/17/15 30/24/19 35/28/21 37/32/27 Approx. packing measurement m Cooling Only RAS 2.0AGV8E RAS 4.0AG(V)8E RAS 6.0AG8E RAS 8.0AG8E RAS 2.5AG(V)8E RAS 5.0AG8E RAS 10AG8E RAS 3.0AG(V)8E RAS 3.5AG(V)8E RAS 4.0AG(V)8E RAS 8.0AG8E RAS 5.0AG8E RAS 10AG8E RAS 6.0AG8E Combined Outdoor Unit Heat Pump RAS 2.0HGV8E RAS 4.0HG8E RAS 6.0HG8E RAS 8.0HG8E RAS 2.5HG8E RAS 5.0HG8E RAS 10HG8E RAS 3.0HG8E RAS 3.5HG8E RAS 4.0HG8E RAS 8.0HG8E RAS 5.0HG8E RAS 10HG8E RAS 6.0HG8E Total Input power cooling kw Total Input power heating kw Sound Pressure Levels db(a) Air Flow Rate (Hi/Me/Lo) m 3 /min Dimensions (HxWxD) mm 800/850/ /850/ /850/ /1000/ /850/ /850/ /1000/ /850/ /850/ /850/ /1000/ /850/ /1000/ /850/350 Net Weight kg Refrigerant type R407C R407C Refrigerant charge kg ? Precharged Length m Liquid line inches 6.35(1/4) 9.53 (3/8) 9.53 (3/8) Ø12.7(1/2) 9.53 (3/8) 9.53 (3/8) Ø15.88(5/8) 9.53 (3/8) 9.53 (3/8) 9.53 (3/8) Ø12.7(1/2) 9.53 (3/8) Ø15.88(5/8) 9.53 (3/8) Gas line inches 15.88(5/8) 19.05(3/4) 19.05(3/4) Ø28.6(1 1/8) 15.88(5/8) 19.05(3/4) Ø28.6(1 1/8) 15.88(5/8) 15.88(5/8) 19.05(3/4) Ø28.6(1 1/8) 19.05(3/4) Ø28.6(1 1/8) 19.05(3/4) Power supply V/Ph/Hz 220/240V 1Ø380/415 3Ø 220/240V 1Ø380/415 3Ø Working Range C Cooling Operation: -5 c/43 c DB Heating Operation: -8 c/15.5 c WB Cooling Operation: -5 c/43 c DB Heating Operation: -8 c/15.5 c WB Approx. packing measurement m
19 Utopia G8 RPFI Technical Description Floor concealed indoor units RPFI Compact design 620mm in height 220mm in depth Space-saving slim unit, only 220mm in depth Slim line design only 220mm in depth allowing the unit to be installed without spoiling the style or beauty of the room. Effective use of space by window With a height of 630mm, may be installed by a window leaving plenty of window space. Best installed in a perimeter zone. Low height Only 630mm. Concealed Floor Mounted Compact design for limited space inside of perimeter wall. So compact that it fits into even the smallest space. Special emphasis placed on interior design compatibility as well as space saving design, allowing it to fit perfectly into the space below a bay window. Optional location for remote control switch Install the PC-P1HE under the plastic cover Floor Mounted Floor mounted systems uncased Model RPFI 1.5FSNE RPFI 2.0FSNE RPFI 2.0FSNE RPFI 2.5FSNE Indoor Unit Configuration Twin Quad Single Twin Triple Quad Single Twin Quad Power Supply V/Ph/Hz V/50Hz V/50Hz Nominal Cooling Capacity kw Nominal Heating Capacity kw Sound Pressure Levels db(a) 38/35/31 39/36/32 39/36/32 42/38/34 Dimensions (HxWxD) mm 620/988/ /1238/ /1238/ /1238/220 Net Weight Indoor unit kg Air Flow Rate (Hi/Me/Lo) m 3 /min 12/10/9 16/14/11 16/14/11 16/14/11 Approx. packing measurement m Cooling Only RAS 3.0AG(V)8E RAS 6.0AG8E RAS 2.0AGV8E RAS 4.0AG(V)8E RAS 6.0AG8E RAS 8.0AG8E RAS 2.5AG(V)8E RAS 5.0AG8E RAS 10AG8E Combined Outdoor Unit Heat Pump RAS 3.0HG8E RAS 6.0HG8E RAS 2.0HGV8E RAS 4.0HG8E RAS 6.0HG8E RAS 8.0HG8E RAS 2.5HG8E RAS 5.0HG8E RAS 10HG8E Total Input power cooling kw Total Input power heating kw Sound Pressure Levels db(a) Air Flow Rate (Hi/Me/Lo) m 3 /min Dimensions (HxWxD) mm 800/850/ /850/ /850/ /850/ /850/ /1000/ /850/ /850/ /1000/875 Net Weight kg Refrigerant type R407C R407C Refrigerant charge kg Precharged Length m Liquid line inches 9.53 (3/8) 9.53 (3/8) 6.35(1/4) 9.53 (3/8) 9.53 (3/8) Ø12.7(1/2) 9.53 (3/8) 9.53 (3/8) Ø15.88(5/8) Gas line inches 15.88(5/8) 19.05(3/4) 15.88(5/8) 19.05(3/4) 19.05(3/4) Ø28.6(1 1/8) 15.88(5/8) 19.05(3/4) Ø28.6(1 1/8) Power supply V/Ph/Hz 220/240V 1Ø380/415 3Ø 220/240V 1Ø380/415 3Ø Working Range C Cooling Operation: -5 c/43 c DB Heating Operation: -8 c/ 15.5 c WB Cooling Operation: -5 c/43 c DB Heating Operation: -8 c/ 15.5 c WB Approx. packing measurement m
20 Utopia G8 RPF Technical Description Floor mounted indoor units RPF Floor Type Slim design, only 200mm deep Low height, only 630mm Light unit Low sound level Space-saving slim unit, only 220mm in depth Slim line design only 220mm in depth allowing the unit to be installed without spoiling the style or beauty of the room. Effective use of space by window With a height of 630mm, may be installed by a window leaving plenty of window space. Best installed in a perimeter zone. Low height Only 630mm. Concealed Floor Mounted Compact design for limited space inside of perimeter wall. So compact that it fits into even the smallest space. Special emphasis placed on interior design compatibility as well as space saving design, allowing it to fit perfectly into the space below a bay window. Optional location for remote control switch Install the PC-P1HE under the plastic cover Floor Mounted Floor mounted systems cased Model RPF 1.5FSNE RPF 2.0FSNE RPF 2.0FSNE RPF 2.5FSNE Indoor Unit Configuration Twin Quad Single Twin Triple Quad Single Twin Quad Power Supply V/Ph/Hz V/50Hz V/50Hz Nominal Cooling Capacity kw Nominal Heating Capacity kw Sound Pressure Levels db(a) 38/35/31 39/36/32 39/36/32 42/38/34 Dimensions (HxWxD) mm 630/1170/ /1420/ /1420/ /1420/220 Net Weight Indoor kg Air Flow Rate (Hi/Me/Lo) m 3 /min 12/10/9 16/14/11 16/14/11 16/14/11 Approx. packing measurement m Cooling Only RAS 3.0AG(V)8E RAS 6.0AG8E RAS 2.0AGV8E RAS 4.0AG(V)8E RAS 6.0AG8E RAS 8.0AG8E RAS 2.5AG(V)8E RAS 5.0AG8E RAS 10AG8E Combined Outdoor Unit Heat Pump RAS 3.0HG8E RAS 6.0HG8E RAS 2.0HGV8E RAS 4.0HG8E RAS 6.0HG8E RAS 8.0HG8E RAS 2.5HG8E RAS 5.0HG8E RAS 10HG8E Total Input power cooling kw Total Input power heating kw Sound Pressure Levels db(a) Air Flow Rate (Hi/Me/Lo) m 3 /min Dimensions (HxWxD) mm 800/850/ /850/ /850/ /850/ /850/ /1000/ /850/ /850/ /1000/875 Net Weight kg Refrigerant type R407C R407C Refrigerant charge kg Precharged Length m Liquid line inches 9.53 (3/8) 9.53 (3/8) 6.35(1/4) 9.53 (3/8) 9.53 (3/8) Ø12.7(1/2) 9.53 (3/8) 9.53 (3/8) Ø15.88(5/8) Gas line inches 15.88(5/8) 19.05(3/4) 15.88(5/8) 19.05(3/4) 19.05(3/4) Ø28.6(1 1/8) 15.88(5/8) 19.05(3/4) Ø28.6(1 1/8) Power supply V/Ph/Hz 220/240V 1Ø 380/415 3Ø 220/240V 1Ø 380/415 3Ø Working Range C Cooling Operation: -5 c/43 c DB Heating Operation: -8 c/ 15.5 c WB Cooling Operation: -5 c/43 c DB Heating Operation: -8 c/ 15.5 c WB Approx. packing measurement m
21 Utopia G8 Centrifugal 5HP Outdoor Units Ducted Condensing Unit Non visible installation: Suitable application in business and housing where it s forbidden or impossible to place outdoor unit outside the building. Avoid legislation and local regulations regarding outdoor units installation. Hitachi high reliable Scroll Compressor, and Utopia series control. Utopia centrifugal New structure and dimensioning according to use of centrifugal fan. Space saving due to use of centrifugal fan. Installation of ducts could be performed. The new unit can be installed in indoor or outdoor locations. Four different configurations for air inlet and outlet (changeable in the field). Compatible with all indoor units. Centrifugal systems Model RASC-5HG8E RASC-10HG8E Nominal Cooling Capacity kw Nominal Heating Capacity kw Cabinet Colour (RAL 9002) Soft Grey Soft Grey (RAL 9002) Sound Pressure Level (1*) db(a) Outer Dimensions (HxWxD) mm 555/1312/ /2050/930 Net Weight kg Refrigerant Charge kg Refrigerant R407C (Factory charged for 10 meters) (2*) R407C (Factory charged for 10 meters) (2*) Compressor Type Hermetic (Scroll) Hermetic (Scroll) Model G500DH G1000EL Quantity un. 1 1 Fan Motor Type Centrifugal Fan Centrifugal Fan Output kw Quantity un. 1 1 Nominal Static Pressure Pa Maximum Static Pressure Pa Connections Service Valves with Flare Nut connection S-Valves with Flare Nut/Flange connection Refrigerant Piping Liquid Line mm (in) 9.53 (3/8) (5/8) Gas Line mm (in) (3/4) 28.6 (1 1/8) Drain Piping (exterior diameter) mm Packing Measurements m Note: (1*). The sound pressure level is based on the following conditions: - 3 m. from the unit front surface. The above data was measured in anechoic chamber so that reflected sound should be taken into consideration in the field. In case of night Shift setting, the noise level decrease about 2 db(a). (2*). The outdoor unit is charged with refrigerant before shipment. The charged volume is suitable for a maximum refrigerant piping of 10m., when combining to a Hitachi standard indoor unit. 41
22 Utopia G8 KPI Technical Description Various Control Examples of Total Heat Exchanger Standard Connection Central Station (PSC-5S) Structure Outdoor air Air supply fan Outdoors Electrical components box Air discharge Fixed Type Heat Exchanging Element Air supply Air filter (for discharge) Indoors Indoor air The newly developed fixed type heat exchanging element with high temperature exchange efficiency equivalent to the rotor type element, has been adopted for the new total heat exchangers (Temp Exchange Efficiency: 77% <in case of 500m 3 /h type unit>). In addition, reliability is increased due to reduction of moving parts. Low weight with simple unit structure: 33kg (in case of 500m 3 /h type unit). Provides a comfortable environment by control interlocking with air conditioning units. Controllable using the remote control switch for the air conditioning unit. Can be controlled in various ways using the remote control switch for the air conditioning unit (PC-P1H). Functions Simultaneous RUN/STOP switch both for air conditioning units and heat exchanging unit Individual operation of heat exchanging unit Fan speed control (high/medium/low) Ventilation mode selection (automatic/heat exchange/bypass) *1 Pre-cool/pre-heat control (interlocking start with delay in 30 or 60 minutes)*1 ON/OFF timer (every half hour, maximum 24 hours) Increased air supply operation Specific alarm display *1 Required option to be selected at remote control switch. Automatic selection of most suitable ventilation mode Depending on temperature conditions both outdoors and indoors, the most suitable ventilation mode is automatically selected, designed for energy efficiency. Example of System Outlook of System Component of System Example of System Outlook of System Component of System PC-P1H SET-FREE PC-P1HE UTOPIA Able to control up to 16 Indoor Units and Total Heat Exchanger Units PC-P1H Remote Control Switch (PC-P1H) CS-NET 1 PC-P1H Hitachi Computer Control Network System CS-NET (version 7) PC-P1H 2 T.H.E+PC-P1H Able to control with PC-P1H directry CS-NET PC-P1H PSC-5S Able to control up to 128 Indoor Units consist of 16 refrigeration series Central Station (PSC-5S) Remote Control Switch (PC-P1H) 4 H-LINK Able to control up to 128 Indoor Units consist of 16 refrigeration series CS-NET Remote Control Switch (PC-P1H) 3 H-LINK PC-P1H ~ 1 5 :INDOOR UNIT :TOTAL HEAT EXCHANGER ( T.H.E ) :NEW AVAILABLE SYSTEM Model KPI-2521 KPI-5021 KPI-8021 KPI CS-NET 5 H-LINK Total heat exchanger Other Characteristics Quiet operation with low noise level of db (A) (at Hi Tap of KPI 5021 Type) has been realised by improving the flow path configuration. Operation not only with SET-FREE Series Indoor Unit, but also with UTOPIA Series Indoor Unit. Connectable to H-LINK System with Central Station or with CS-NET in Operation with Indoor Unit. Flexible Duct Installation: The connecting direction of duct at outdoor side (OA,EA) can be changed according to the condition of the installation site (2 directions). Reduced packing material for environment protection. The wood for the packing use has been reduced for environment protection. Can also be installed upside down. Power Supply AC 1 -, V / 50Hz, 60Hz*1 Air Flow Rate (m 3 /h) Hi 250/ / /800 1,000/1,000 Me 250/ / /800 1,000/1,000 Lo 165/ / / /720 Temperature Exchange Efficiency (%) Enthalpy Exchange Efficiency Heating/Cooling 74/68 73/68 73/68 73/67 Sound Pressure Level Hi / / / /36 (Overall A Scale) at 1.5m Me 25-26/ / / /34 from the unit (under)*3 *4 Lo 21-22/ / / /30 External Pressure (PA) Hi 65/ / / /200 *2 Me 40/50 60/60 100/ /110 Lo 20/20 30/20 70/80 80/60 Outer Dimensions Height Width Depth Net Weight Kg Approx Packing Measurement m NOTES: *1 KPI has different units according to the applied power supply, v, 50Hz and 200V/60Hz *2 Use it under the following conditions. KPI-8021: 29Pa or more, KPI-10021: 49Pa or more *3 The sound pressure level is based on the following conditions; 1.5 meter beneath the unit and this data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field. *4 The sound pressure is based on the total heat exchange mode. In case of the bypass ventilation mode, the sound pressure level increased by approximately 1dB(A). 43
23 System Example 1 : Outdoor Units 16 PC USB Connection (Field supply) H-LINK Max. 16* 1 Outdoor Units HARC 40 Max. 16* 3 Indoor System Example 1 : Outdoor Units 16 (Option) Units per cycle PCB for 10HP and 128 USB Connection units per Harc-box (Field supply) PC in CS-NET system H-LINK Max. 16* 1 Outdoor Units PCB Control systems System Example 2 : 16<Outdoor in CS-NET system Units 128 PC USB Connection (Field supply) H-LINK System Example 2 : 16<Outdoor Units 128 PC USB Hub (Field supply) HARC 40 (Option) HARC 40 ID=0(Option) USB USB Hub Connection (Field (Field supply) H-LINK HARC 40 ID=0(Option) HARC 40 ID=7(Option) PCB H-LINK HARC 40 ID=7(Option) H-LINK PCB PCB PCB Max. 16* 3 Indoor Units per cycle for 10HP and 128 units per Harc-box Max. 16* 1 Outdoor Units Max. 16* 1 Outdoor Units Max. 16* 1 Outdoor Units Max. 16* 3 Indoor Units per cycle PCB for 10HP and 128 units per Harc-box Max. 16* 1 Outdoor in CS-NET Units system Max. 16* 3 Indoor Units per cycle for 10HP and 128 units per Harc-box in CS-NET system PCB PCB PCB PCB PCB CS-NET Features * 1: If the number of indoor units per a refrigeran cycle is 17 or greater, count one outdoor unit as two units. *2: Max. total length of transmission wire is 1,000 meters. * 3: Max. 8 units for 5HP *1: If the number of indoor units per a refrigerant cycle is 17 or greater, Max. 13 count units one for outdoor 8HP unit as two units. Max. 16 units for 16 and 20HP Max. 27 units for 24HP *2: Max. total length of transmission wire is 1,000 meters. Max. 32 units for 30HP *3: Max. 8 units for 5HP Max. 13 units for 8HP Max. 16 units for 16 and 20HP Max. 27 units for 24HP Max. 32 units for 30HP H-Link Transmission System This system connects the control wires for the outdoor and indoor units across two or more refrigerant systems. Regardless of the order or number of units to be connected, all the units can be controlled once they have been connected. By this method, design flexibility is very high, installation is easy and total costs are reduced. Furthermore, central control is possible by connecting CS-NET to H-LINK wiring located in the room next to the room where CS-NET is installed. Computer Controlled Network System Control Function On/Off control Operation mode setting Temperature setting [setting range: Cooling 19 C 30 C, Heating 19 C 30 C] Air direction setting Remote control fully allowed/prohibited Remote control partially allowed/prohibited Fan speed setting Air direction setting (cannot be set by wireless remote control) Filter sign resetting Annual timer Monitoring Function On/Off Control Operation mode Set fan speed Set air direction Set temperature Remote control prohibition setting Filter sign Alarm Alarm code Air inlet temperature Floor layout plan (BMS style) Web server functionality (internet/intranet connection) CS-NET HARC-40 45
24 Easy Set Up Floor Layout Plan Web Connection after Easy Set Up CS-NET set up and operation Module configuration box Click on the Module Configuration Icon of the first Unit to open the Module Configuration Box. The Icon for the open Module will have a yellow surround to indicate the Module that is open. Operation When the Set Up and Auto Configuration have been completed, the Unit information must be entered in each Individual Module. It is important for future service to enter the Serial Numbers and Models in their respective fields, as this will avoid time consuming searching in the event of warranty claims or spare parts identification. Graphic Representation When the systems are running, the operating conditions for each unit are shown in a graphical layout which can be operated through FAULT and then SYSTEM STATUS. By clicking on DISPLAY the operating conditions will be shown in a tabular form. This graphical layout is not available for UTOPIA or UTOPIA BIG units. 47
25 PC-P1HE Remote Control Switch Specifications of HARC-BX Features a wide range of functions, including a large liquid crystal display screen, self-diagnostic capabilities, and a timer which can be set in 0.5 hour intervals. A convenient remote control which is supplied as standard with all units. Type Standard Option A Option B Connectable Q ty Control Monitor Control Monitor Control Monitor Run/Stop & Alarm* Operation Mode Set Temp Fan Speed Louver Position RC. Sw.Permission/Prohibition Alarm Code IU Inlet Air Temp IU Outlet Air Temp Outdoor Air Temp Thermo-ON/OFF Remark Use PC-P1H or PC-2H2 Maximum Wiring Length 1000m (Bus Total length) *Alarm for monitor only PC-LH3A Wireless Remote Control Switch No wiring work required. Two or more units can be operated simultaneously by remote control. The receiver kit is integral in wall mounted units. Receiver kit PC-RLH11 is required for all other models. PC-P5H Simplified remote control switch The main function of this easy-to-use remote control is temperature setting. Suitable for a variety of applications such as hotels, restaurants and offices. 2 remote controls or group control (for 16 controls max) can be used, similar to the standard remote control. If a problem occurs, an alarm code immediately shows the details of the problem. *When the half-size remote control is used, cooling/heating is automatic. Lon Works Gateway Interface to LON WORKS BMS Systems Using HARC-BX allows control of up to 5 setting points and remote monitoring of up to 9 valves. By connecting HARC-BX to H-LINK, a group of up to 16 remote controls can be used and up to 64 indoor units can be controlled. interface PSC-5S Centralised Remote Control Switch Remote controllers This Central Station enables centralised control of up to 16 groups of indoor units (at maximum 256 indoor units). Features a wide range of functions, including a large liquid crystal display screen and alarm code. User friendly Central Station. Remote start/stop and common fault signal available. PSC-5T 7-Day Timer The 7-Day Timer allows long-term unattended control. By plugging this time to the optional remote control switch or Central Station, daily ON/OFF operation control throughout the week is available. ON/OFF setting is available three times a day by two different patterns. HARC-BX 49
26 Indoor Units 4-Way Cassette Type Item Receiver Kit for Wireless Control RCI FSN1E PC-RLH8 (on the panel) 2-Way Cassette Type Item Receiver Kit for Wireless Control RCD FSN PC-RLH9 (on the panel) Mini Wall Mounted Type Item Wireless Receiver Kit RPK FSNM As standard In-the-Ceiling, Wall, Floor and Ceiling Type Item RPI ( HP), RPK ( HP), RPC ( HP), RPF ( HP), RPFI ( HP) Receiver Kit for Wireless Control (with 5m cable) PC-RLH11 (wall mounted) Optional parts Control System Compatibility Item RPI-FSN RCI-FSN RCD-FSN RPK-FSN RPC-FSN RPF(1)-FSN KPI Remote Control Switch* 1 PC-P1H (without cable) Wireless Remote Control Switch* 2 PC-LH3A (new) Half-size Remote Control Switch PC-P5H 7-Day Timer PSC-5T Centralised Remote Control Switch* 3 PSC-5S Remote Control Cable PRC-10E1, 15E1, 20E1, 30E1 for PC-P1H 3P Connector Cable PCC-1A Remote Sensor THM-R2A Computer Controlled Network System CS-NET *1 As the PC-P1H does not include a remote control cable, prepare one in the field, or use PRC-10E1, 15E1, 20E1, 30E1. *2 PC-LH3 can be used instead of PC-LH3A. *3 Supply 220V or 240V 51
27 Specifications in this catalogue are subject to change without notice in order that HITACHI may bring the latest innovations to their customers. Omitting typing errors. Hitachi Europe Ltd Whitebrook Park Lower Cookham Road Maidenhead Berkshire SL6 8YA United Kingdom Distributed by: HELGB-SF-002
Models Utopia ES Utopia IVX Utopia DC Inverter Utopia Fixed Speed Utopia Centrifugal
Utopia Split Systems Models Utopia ES (7.1-14 kw) Utopia IVX (7.1-30 kw) Utopia DC Inverter (5-14 kw) Utopia Fixed Speed (6.3-12.5 kw) Utopia Centrifugal (12.5-25 kw) Contents Company Profile 4 Utopia
UTOPIA COMMERCIAL SPLIT AIR CONDITIONING SYSTEM. G7 Series (5-25 kw) DC INVERTER Series (7-12,5 kw) KPI - Total Heat Exchanger
UTOPIA G7 Series (5-25 kw) DC INVERTER Series (7-12,5 kw) KPI - Total Heat Exchanger www.hitachiaircon.com [email protected] Specifications in this catalogue are subject to change without
york air-conditioning products Residential & VRF News 2015
york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter
Inverter Air Conditioning for Light Commercial Use
Inverter Air Conditioning for Light Commercial Use 02 Cost Saving Comfort An efficient use of time 03 SDISuper Digital Inverter Very efficient energy consumption Keeps down operating costs Heater operation
Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE
Hitachi Air Conditioning Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE Contents Page 04 Product Range 08-09 RAC Summit Wall Mounted 10 RAC Shirokuma Wall mounted 11 RAC S Series - Wall
UTOPIA DC-INVERTER ES SERIES HVRN1/H(V)RNS(E)
UTOPIA DC-INVERTER ES SERIES HVRN1/H(V)RNS(E) Technical Catalogue Outdoor Units: 2~10 HP Indoor Units Type: 4-Way Cassette 2-Way Cassette Wall Ceiling In-the-Ceiling Floor Floor Concealed Specifications
More than Air Conditioning. Catalogue 2004/2005. Air Conditioning Program R 407C R 410A
More than Air Conditioning Catalogue 2004/2005 Air Conditioning Program R 407C R 410A MITSUBISHI ELECTRIC Air Conditioning Systems As one of the world s leading technology companies, MITSUBISHI ELECTRIC
Models Monozone/Multizone (NH4/QH4) Summit (YH4) Big Flow (GH4/G4) New Air Exchanger (JX4)
room air conditioners Models Monozone/Multizone (NH4/QH4) Summit (YH4) Big Flow (GH4/G4) New Air Exchanger (JX4) Contents Company profile 4 Product range overview 6 Standards and quality certificates 8
AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.
AquaFREE System Technical Catalogue Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.5/6)H(1/3) Specifications in this manual are subject to change without notice
FULL DC INVERTER SYSTEMS
FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR DESIGN & FLEXIBLE COMBINATION commercial air conditioners SDV4 2011/2012 AIR CONDITIONING 1 WELCOME TO THE WORLD of SINCLAIR AIR CONDITIONERS Company operation
AquaFREE system. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE
AquaFREE system Technical Catalogue Outdoor units: RAS(3~5)HVRNE RAS(4/5)HRNE Indoor units: RWM(3~5)FSN1E RWM(3~5)FSN1E(4.5/6)H(1/3) RWM(3~5)FSN1ES1 RWM(3~5)FSN1E(4.5/6)SH(1/3) Specifications in this
ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.
ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2
1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/
1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/ ISO 9001 ISO 14001 Certified number : 01 100 89394 Certified number : 01 104 9245101 Fujitsu General (Thailand) Co.,
LG Electronics AE Company, Commercial Air Conditioning
www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,
LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy
LG Air conditioning Company Multi V Water Ⅱ Air Conditioning Academy 1.1 What is Multi V Water II? High Performance Prospect rights Water pipe Refrigerant pipe Indoor unit Beautiful Exterior Convenience
DUCTED AIR CONDITIONING SOLUTIONS
DUCTED AIR CONDITIONING SOLUTIONS H I G H E N E R G Y E F F I C I E N C Y B A C K E D B Y A 5 Y E A R F U L L P A R T S & L A B O U R W A R R A N T Y DUCTED RANGE WHY CHOOSE FUJITSU? AUSTRALIA S FAVOURITE
Earth can hardly wait for a change in the atmosphere. Nor can we. By making air conditioning supremely energy-efficient, quiet, easy to install, and
1 Earth can hardly wait for a change in the atmosphere. Nor can we. By making air conditioning supremely energy-efficient, quiet, easy to install, and cost-effective, Toshiba aims at the heart of growing
The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity
Liebert HPF The High Performance Floormount Indoor Package Cooling Solution Precision Cooling for Business-Critical Continuity We re Emerson Network Power, backed by Emerson, a global company that brings
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes
Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,
MULTISPLIT SYSTEMS AIR CONDITIONING SYSTEMS
MULTISPLIT SYSTEMS AIR CONDITIONING SYSTEMS POER, FLEXIBILITY, RESIDENTIAL Carrier presents the new line of multi-split systems A complete and flexible range designed to meet every residential and light
Air Conditioning For Large Buildings
Air Conditioning For Large Buildings Index Introduction 3 Industry leading energy savings 6 New smart & sensitive VRF control 10 Industry leading layout flexibility 14 Other features 18 Outdoor units Outdoor
DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS
DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS AN EXCELLENT CHOICE IN COOLING, COMFORT AND CONVENIENCE Why choose a Mini-Split system? Installing
New Deluxe Wall Mounted Heat Pump Series EXTERIOS
New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History
Unico Inverter. Unique and efficient.
Unico Inverter. Unique and efficient. INTERNATIONAL PATENT PENDING The first fixed air conditioner without outdoor unit featuring DC Inverter technology. Great performance, reduced consumption. Designed
Air Conditioning for Small and Medium-size Buildings
Air Conditioning for Small and Medium-size Buildings Defining a HIGHER standard The all-new MiNi-SMMS air conditioner lineup lets you cool or warm as many as 12 *1 rooms with a single system. Outdoor units
How To Make A High Efficiency Thermostat
Zoning with Variable Speed Mini-Split Systems Fujitsu Service Training Welcome - Thank you for attending Did you know? In 1940 only 42% of homes in the US had central heating In 1970 20% of homes had central
FTQ. Daikin Inverter Ducted Heat Pump
FTQ Daikin Inverter Ducted Heat Pump A TRADITIONAL CENTRAL AIR SYSTEM MADE BETTER WITH DAIKIN CONSTANT COMFORT INVERTER TECHNOLOGY. The Daikin Inverter Ducted Heat Pump line is a cost effective alternative
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient
AIR-CONDITIONER SPLIT TYPE
FILE NO. A08-016 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE RAS-M10PKVP-E, RAS-M13PKVP-E, RAS-M16PKVP-E, RAS-M18PKVP-E / RAS-M10PKVP-ND, RAS-M13PKVP-ND, RAS-M16PKVP-ND, RAS-M18PKVP-ND / RAS-3M26GAV-E1,
technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air
technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t
UTOPIA RASC-G8 SERIES
UTOPIA RASC-G8 SERIES Technical Catalog Outdoor Units: 5, 10 HP CONTENTS 0/1 0 CONTENTS PART I TECHNICAL DATA 1 FEATURES AND BENEFITS 1.1. System description 1/2 1.2. Installation advantages 1/4 2 GENERAL
hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &
hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS
SALES BULLETIN. Key Features. New 7 Series Under Ceiling Indoor Units
SALES BULLETIN Key Features 1. Chassis completely re designed 2. Increased product range, now includes 6HP model 3. New features to enable easy installation a. Easy access hanger b. Easier wiring connections
For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System
For Residential & Light Commercial Applications 4 Ton 8 Zone Multi Split Heat Pump System EXPERTISE AND INNOVATION The Super Multi PLUS Split System is the ultimate, flexible solution for individual zone
R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power
R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor
NEW 3-PIPE ECOi MF2 SERIES
NEW 3-PIPE ECOi MF2 SERIES SIMULTANEOUS HEATING AND COOLING VRF SYSTEM Internet Control Ready INTERNET CONTROL NEW Energy Environmentally friendly refrigerant R410A Down to -20 ºC in heating mode OUTDOOR
Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed
Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed Rely on GD to provide the perfect fit The perfect fit to maximise productivity The growing industrial demand for compressed air requires
UTOPIA RASC-HNE SERIES
UTOPIA RASCHNE SERIES Technical Catalogue Centrifugal Outdoor Units: 5, 10 HP The specifications in this Manual are subject to change without notice in order that HITACHI may bring the latest innovations
ECO-AIR AIR CONDITIONING www.northamericanhvac.com
INDEX ACCESSORIES INSTALLATION... 3-7 LINE SETS... 3-7 GEOTHERMAL... 3-8 WIRING CABLE... 3-8 CIRCULATOR PUMPS (PRO-TECH MODEL)... 3-9 DC INVERTER SINGLE ZONE HEAT PUMP... 3-6 DC INVERTER TECHNOLOGY...
INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK
INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK CL - CH - CK Direct driven solution for industry Proven technology, solid construction The CL - CH - CK units are directly driven air-cooled, single
Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75
Specifications COOLING ONLY / HEAT PUMP 005 006 007 Capacity (Eurovent) Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Nominal input (Eurovent) Cooling kw 1.89 2.35 2.95 Heating kw 1.97 2.24 2.83 EER
HP switch LP switch Discharge thermo Comp. Surface thermo
1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion
technology innovation, comfort for your home. The perfect blend of
The perfect blend of innovation, & technology comfort for your home. Air conditioning for your home is all about comfort. No matter what Australia s harsh climate can dish out. From summer scorchers to
COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C
COOLS conditioned server - racks for direct installation into the room COOLSIDE box INVERTER R410A E C 2 COOLSIDE box GENERAL FEATURES COOLSIDE BOX is a split system consisting of an outdoor motocondensing
Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO
Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO The sum of technology TriAB Air ends The BALMA screw compressors are fitted with the unique TriAB air ends that are designed and
Pioneer in sustainability
Pioneer in sustainability Over 100 years ago Carrier helped pioneer a new industry, and in the last two decades we have pioneered environmentally sensitive products with a reduced impact on the environment.
We have been working in an ideal climate for thirty years.
Underfloor cooling We have been working in an ideal climate for thirty years. A climate that has brought us to a position of leadership in Italy in the field of radiant heating and cooling. RDZ was the
Heat Pump Product Brochure 2015/2016. Premier Series Hi-Wall Split Systems. Everyday Comfort
Heat Pump Product Brochure 2015/2016 Premier Series Hi-Wall Split Systems Everyday Comfort Everyday Innovation We design with you in mind. You ll find that Haier Heat Pump units are quiet, efficient and
HITACHI INVERTER-DRIVEN MULTI-SPLIT SYSTEM HEAT PUMP AIR CONDITIONERS
HITACHI INVERTER-DRIVEN MULTI-SPLIT SYSTEM HEAT PUMP AIR CONDITIONERS SET FREE FSG(1)/FS3, FS5 SERIES AND SET FREE FXG/FX3 SERIES Models In-the-Ceiling Type RPI-0.8FSG1 RPI-2.5FSG1 RPI-8FSG1
Contents. Part 1 General Information... 1. Part 2 Outdoor Units... 9. Part 3 Installation... 50. Part 4 Troubleshooting 73
MCAC-VTSM-2013-03 R410a Full DC Inverter Mini VRF Contents Part 1 General Information... 1 Part 2 Outdoor Units... 9 Part 3 Installation... 50 Part 4 Troubleshooting 73 Part 5 Control System... 100 Manufacture
Inverter Air Conditioning for Light Commercial Use
Inverter Air Conditioning for Light Commercial Use Index Introducing Light Commercial 4 SDI-Super Digital Inverter 6 DI-Digital Inverter 7 DI Big 8 SDI-Super Digital Inverter & DI-Digital Inverter Lineup
UDSA - UDSBD unit heater
APPLICATIONS Heating >> FACTORIES >> WAREHOUSES >> HALLS >> SHOWROOMS >> GREENHOUSES >> RETAIL >>... UDSA - UDSBD unit heater www.reznor.eu V3 gas fired unit heater Reznor V3 unit heaters are one of the
Air Conditioners Technical Data
Air Conditioners Technical Data O u t d o o r U n i t E E D E N 2-0 0 RX-JV Outdoor Unit RX-JV TABLE OF CONTENTS RX-JV Features............................................................. 2 2 Specifications.......................................................
SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI R410A Models Indoor unit Outdoor unit AB*14LBAJ AB*18LBAJ AB*F14LAT
ARMSTRONG AIR HEAT PUMPS www.armstrongair.com
INDEX ELECTRIC FURNACE MODULAR AIR SYSTEM EFC/EFV... 5-10 electric Heat Kits... 5-11 evaporator coils EC1P / EM1P UPFLOW / COUNTERFLOW APPLICATIONS and upflow / horizontal applications (CASED)... 5-6 5-7
Screw Compressors 11-22kW
INDUSTRIALS GROUP Screw Compressors 11-22kW KSA Plus Fixed Speed, KSV Variable Speed Smart and affordable CHAMPION COMPRESSED AIR TECHNOLOGIES KSA Plus Screw Compressors Up to 45 C ambient temperature
CRAC Precision climate control units for data centres
CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have
FTXS. Wall Mount Heat Pump or Cooling Only
FTXS Wall Mount Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FTXS SkyAir systems feature streamlined, wall mounted indoor units paired with quietly compact outdoor units. Available in both
LG AIR CONDITIONERS 2014 Ducted Split System
Australia Pty Ltd. New South Wales / Head Office 2 Wonderland Drive EASTERN CREEK NSW 2766 PH : 02-8805-4000 FAX : 02-8805-4248 AUS-DU1309 Queensland 23 Terrace Place MURARRIE QLD 4172 PH : 07-3908-9000
III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014
III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014 III.1. Large Roof Mount PN: 89-3037 Roof Mount Unit Eco 136 Parallel roof mount Air-conditioning and ventilation systems The Eco 136
KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle
KSV70HRF RRP AUS $1,709.00 Split System Reverse Cycle air conditioner featuring inverter technology, clean front with LED display, Bio and active carbon filter, 2 way auto swing (up, down), remote (7.1kW
AIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW -
AIR-COOLED CHILLERS APPLIED SYSTEMS www.daikin.eu Cooling Only Heat pump EUWA*5-24KAZW - EUWY*5-24KAZW - Environmental Awareness Daikin and the Environment In recent years, motivated by a global awareness
SINGLE PACKAGE VERTICAL AIR CONDITIONERS
SINGLE PACKAGE VERTICAL AIR CONDITIONERS AIR CONDITIONERS l HEAT PUMPS l ELECTRIC HEAT QUIETER BY DESIGN SIMPLE TO INSTALL CONCEALED INSTALLATION www.friedrich.com VERT-I-PAK ideal for extended stay properties,
- White Paper - Data Centre Cooling. Best Practice
- White Paper - Data Centre Cooling Best Practice Release 2, April 2008 Contents INTRODUCTION... 3 1. AIR FLOW LEAKAGE... 3 2. PERFORATED TILES: NUMBER AND OPENING FACTOR... 4 3. PERFORATED TILES: WITH
2015 / 16. price list. Airconditioning systems
2015 / 16 price list Airconditioning systems TERMS OF BUSINESS General As far as nothing else has been declared, the general terms of business and the agreed purchase conditions including the sales discounts
Installation, operation and maintenance manual TX 35A
Installation, operation and maintenance manual TX 35A Rev.10 may 2012 Page 1 of 18 1.0.0 Table of contents INSTALLATION, OPERATION AND MAINTENANCE MANUAL...1 1.0.0 TABLE OF CONTENTS...2 2.0.0 ILLUSTRATIONS...2
Monozone/Multizone (QH8,NH7A,NH6A,NH5,QH5) Summit (WX8)(FX8)(DH7A)(FH6)(YH6)(YH5A) Bigflow (G4,GH4) Technical Catalogue
Monozone/Multizone (QH8,NH7A,NH6A,NH5,QH5) Summit (WX8)(FX8)(DH7A)(FH6)(YH6)(YH5A) Bigflow (G4,GH4) Technical Catalogue Monozone/Multizone Outdoor Unit RAC RAM Monozone/Mutizone Indoor Unit RAK RAF RAI
Development and testing of a multi-type air conditioner without using AC inverters
Energy Conversion and Management 46 (2005) 373 383 www.elsevier.com/locate/enconman Development and testing of a multi-type air conditioner without using AC inverters Shih-Cheng Hu *, Rong-Hwa Yang Department
Gree Solar Hybrid Hi Wall Inverter Air Conditioner
Gree Solar Hybrid Hi Wall Inverter Air Conditioner Utilize the natural power of the sun to heat or cool your home. Find out more at www.greeonline.com Why Choose a Solar Hybrid Inverter? The new Gree Solar
Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty
Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp
LG AIR CONDITIONING SYSTEMS
LG AIR CONDITIONING SYSTEMS THE NEW STANDARD IN COMFORT INNOVATIVE COMFORT SOLUTIONS AT LG, WE BELIEVE COMFORT SHOULD ALWAYS BE BEAUTIFUL. 4 Table of Contents INTRODUCTION 04-07 ART COOL 08-11 SINGLE
AIR DEHUMIDIFYING 2011. Condensation drying for industry and trade
AIR DEHUMIDIFYING 2011 Condensation drying for industry and trade Condensation drying for industry and trade 2011 DH 18 domestic dehumidifiers Development, production and sales: All from a single source
Samsung Room Air Conditioning
Samsung Room Air Conditioning Air Conditioning Solutions from a Trusted Brand At the heart of family living is the home, a place full of special moments and wonderful memories where families live and
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table
SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS
innovative comfort solutions
engineering and specifications Guide duct-free air conditioning systems Art cool inverter flex multi-split floor standing ceiling cassette PTAC PTHP through-the-wall innovative comfort solutions 1 AT LG,
CADB and CADT-D / DI / DC Series
HEAT RECOVERY UNITS CADB and CADT-D / DI / DC Series NEW The CADB, CADT heat recovery range consists of: - Self-supporting casing with extruded aluminium profile structure and beige plastic coated galvanised
FHQ. Ceiling Suspended Heat Pump or Cooling Only
FHQ Ceiling Suspended Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FHQ ceiling suspended SkyAir systems are ideal for applications without false ceilings. Installed from the structure, this
PANASONIC TROUBLE SHOOTING GUIDE
A General Guide To Room Style Products Pipework Pipe sizes and lengths should be as the relevant Technical Guide Both lines should be insulated No line accessories or oil traps should be fitted In cooling
NEW COMMERCIAL RANGE EXTREMELY EFFICIENT 2013 / 2014
NEW COMMERCIAL RANGE EXTREMELY EFFICIENT 2013 / 2014 PACi STANDARD PACi ELITE NEW COMMERCIAL AIR TO AIR 2013 / 2014 NEW 2013 / 2014 COMMERCIAL RANGE Summary PANASONIC LEADING THE WAY IN HEATING & COOLING...4
SiBE12-625. D-Series / E-Series. [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump
SiBE12-625 D-Series / E-Series [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump SUPER MULTI NX D-Series / E-Series Cooling Only Indoor Unit FTKS20D3VMW FTKS20CAVMB FDKS25CAVMB
SWIMMING POOL HEAT PUMP Owners Manual
SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor
The ABC s of VRF: A Green HVAC Technology An Ideal Green School Solution. Presented by: Fujitsu General America, Inc.
The ABC s of VRF: A Green HVAC Technology An Ideal Green School Solution Presented by: Fujitsu General America, Inc. What to look for in a Green HVAC solution? What if your HVAC system could provide Individual
INVERTER IN-CEILING CASSETTE. Ideal for various applications including the lounge, family room, restaurants, hotels, offices and meeting rooms.
INVERTER IN-CEILING CASSETTE Ideal for various applications including the lounge, family room, restaurants, hotels, offices and meeting rooms. INVERTER TECHNOLOGY PFC Control in Power Input DC Inverter
Chiller/Heat pumps 30AWH. Reversible. Monobloc inverter
Chiller/Heat pumps 30AWH Reversible Monobloc inverter C O M P A C T, R E L I A B L E A N D E F F I C I E N T Reversible Compact, reliable and efficient 2 The new AquaSnap PLUS chillers and reversible heat
Super Modular Multi Design Manual HFC R-410A. Indoor unit. Outdoor unit
Ref.-No. SMMS02-AE-10-05 Indoor unit 4-way ceiling cassette MMU-AP0091H, AP0121H, AP0151H, MMU-AP0181H, AP0241H, AP0271H, MMU-AP0301H, AP0361H, AP0481H MMU-AP0561H 2-way ceiling cassette MMU-AP0071WH,
Air conditioning unit Saphir vario. 2. Product information for the new Truma air conditioning unit. Comfort on the move
Air conditioning unit 2. Product information for the new Truma air conditioning unit October 2006 Edition Comfort on the move Air conditioning systems Manoeuvring systems Energy systems Heating systems
News in Data Center Cooling
News in Data Center Cooling Wednesday, 8th May 2013, 16:00h Benjamin Petschke, Director Export - Products Stulz GmbH News in Data Center Cooling Almost any News in Data Center Cooling is about increase
Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System
Auxiliary HVAC RAM ProMaster Standard Tie-in Extreme Climate System Auxiliary HVAC High performance aftermarket heating and cooling systems engineered for vehicle specific platforms that minimize install
Elements of Energy Efficiency in Data Centre Cooling Architecture
Elements of Energy Efficiency in Data Centre Cooling Architecture Energy Efficient Data Center Cooling 1 STULZ Group of Companies Turnover 2006 Plastics Technology 400 Mio A/C Technology 200 Mio Total
-~ available. Power consumption during operation is substantially less than that of lower rated
Introduction Specifically designed for small to medium sized areas the SANYO SAP range is the ideal solution when you need quiet, efficient room air conditioning to create a comfortable environment within
Multi Air Conditioning System for Buildings
Multi Air Conditioning System for Buildings 6, Suenaga, Takatsuku, Kawasaki 238502, Japan http://www.fujitsugeneral.com/ ISO 900 ISO 400 ISO 900 ISO 400 Certified number : 0 00 89394 Certified number :
INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. C11-211 REV. 3 Supersedes Form No. C11-211 Rev. 2 INDOOR COILS RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant CASED/UNCASED COILS
INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. C11-211 REV. 7 Supersedes Form No. C11-211 Rev. 6 INDOOR COILS RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM
HDA -----------------------------------------------------------
----------------------------------------------------------- Lightstrips ---------------------------------------------------------------------- Ceiling system for heating and cooling LIGHTSTRIPS LIGHTSTRIPS
IR410AI. The flexible solution. Simple, one touch control
The flexible solution The new SANYO Flexi Multi range of heat pump multi split systems are the ideal, flexible solution for providing quiet and efficient air conditioning to 2, 3 or 4 areas from a single
UR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm)
UR...3 Heat recovery unit URX CF...7 Heat recovery unit with refrigerant circuit(442-1947 cfm) URHE CF...11 High efficiency heat recovery unit with refrigeration circuit(588-1942 cfm) UR Heat recovery
International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS
International Telecommunication Union ITU-T TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU Technical Paper (13 December 2013) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES