More than Air Conditioning. Catalogue 2004/2005. Air Conditioning Program R 407C R 410A
|
|
|
- Lee Johnston
- 9 years ago
- Views:
Transcription
1 More than Air Conditioning Catalogue 2004/2005 Air Conditioning Program R 407C R 410A
2 MITSUBISHI ELECTRIC Air Conditioning Systems As one of the world s leading technology companies, MITSUBISHI ELECTRIC is committed to providing products and solutions which will enhance the quality of our lives at home, at work and at play. Our outstanding range of split and multi-split air conditioning systems reflect this philosophy. Whether you are an installer, specifier or user, you will appreciate the combination of quality, energy-efficiency, reliability and ease-of-installation that MITSUBISHI ELECTRIC Environmental Control products offer.
3 New technology, more comfort, more energy-efficiency - high-quality air conditioners of MITSUBISHI ELECTRIC! Product series The program offers you more choice than ever before. So whatever the application - a shopping centre, a hotel, restaurant, shop or even a domestic home - the different product series provide the optimum fit. In-ceiling cassettes Contents Units of the M Series are designed for smaller rooms, each outdoor unit requires up to 4 indoor units. M-Series 4 The Mr. Slim Series is applied for middle-sized rooms and is available as single-split and as multi-split system in parallel mode. The City Multi Series convinces with cooling capacity of 14 kw till 84 kw in a refrigerant cycle used for big projects. Wall mounted systems M-Series Accessories Mr. Slim- R407C-Series New technology The inverter technology and new refrigerant R410A enable more energy efficiency. All indoor units can be controlled separately for customised adjustment of temperature. Easy installation The environment-friendly systems of MITSUBISHI ELECTRIC can be installed with minimum work. Space-saving and compact units are available for wall or floor mounting - for a flexible planning and design of structures. The air conditioning systems are expandable for subsequent increasing of the capacity at any time. Floor standing units Ceiling suspended systems Mr. Slim- R410A-Series Power Inverter Mr. Slim- Series Accessories City Multi- Series City Multi- Series Accessories Rating conditions COOLING Indoor: 27 C DB / 19 C WB Outdoor: 35 C DB / 24 C WB Outdoor water temperature for WR2 30 C HEATING Indoor: 20 C DB Outdoor: 7 C DB / 6 C WB Outdoor water temperature for WR2 20 C Refrigerant piping length 5 m / 7.5 m* (one way) H = 0 m Sound pressure level measured in anechoic room, at a position 1 m in front of the outdoor unit * For PUH-P8/10MYA and City Multi Above ceiling concealed ducted systems Lossnay Ventilation Series Dehumidifier
4 M Series Split- and Multi-Split Systems Cooling 2.3 kw kw The outstanding M Series brings legendary Mitsubishi Electric quality to the low-capacity air conditioning class. M Series units are perfect for small living spaces like offices, restaurants and small shops, where their unobtrusive appearance and quiet operation are important advantages. Ultra-energy-efficient M Series systems are designed to give lowest possible running costs, with innovative energy-saving features like `Econo-Cool, which direct airflow towards room occupants. This can allow set temperatures to be raised by 2 C with no loss in comfort and a 20% gain in energy efficiency. 4
5 Lowest noise levels With noise levels down to just 21 db(a) Excellent control features M Series remote controllers incorporate easy-to-use features like `IFeel control, which memorises the user`s ideal temperature and recreates it precisely. Multi-splits The M Series includes split system models, running up to four indoor units from one outdoor unit. Plus... Optional high-efficiency air cleaning filters; deodorising and antibacterial Catechin filters available for wallmounted systems Rapid room cooling with swing mode feature Remote control of five different angles of airflow to reach ideal temperatures in optimum time A wide range of indoor units and dual-use units for either floor or ceiling installation Quick and easy installation Auto restart function Winterkit in cooling mode up to -15 C for inverter models and a wind-protected installation Range of M Series Cooling Indoor: C DB C WB Outdoor: C DB Non-Inverter models and MXZ-A18 WV C DB Inverter types Heating Indoor: C DB Outdoor: C DB C WB MSC Cooling Only Wall Mounted Systems MS Cooling Only Wall Mounted Systems MSC Cooling/Heating Wall Mounted Systems MSH Cooling/Heating Wall Mounted Systems MCF Cooling Only Floor or Ceiling Mounted Systems MCFH Cooling/Heating Floor or Ceiling Mounted Systems MSZ Inverter Single Split Cooling/Heating Wall Mounted Systems SLZ Inverter Cooling/Heating 4-Ceiling Cassette Systems SEZ Inverter Cooling/Heating Ceiling Concealed Systems MSX Multi Split Systems Cooling Only MXZ Inverter Multi Split Systems Cooling/Heating M SERIES Accessories/Optional Parts/Refrigerant
6 Series MSC Cooling Only Wall Mounted Systems Energy-saving rotary piston compressor Extremely quiet operation with noise level of only 25 db(a)* `Swing Mode -function enables automatically a more natural and comfortable airflow throughout the room Factory charged with refrigerant R410A Hand-held controller with `fuzzy logic control Remote control for five different angles of airflow direction Auto restart function 24 h Timer Long-life and washable Catechin filters for deodorising and prevention of bacteria and viruses Accessories: Additional filters available to keep air fresh, please view page 24 * MCS-A07/09YV MSC COOLING ONLY - WALL MOUNTED SYSTEMS INDOOR UNIT MSC-A07YV MSC-A09YV MSC-A12YV CAPACITY (kw) Cooling AIRFLOW (m 3 /h) Low High NOISE db(a) Low High WEIGHT (kg) DIMENSIONS (mm) Width Depth Height , 1, 50 RUNNING CURRENT (A) OUTDOOR UNIT MU-A07YV MU-A09YV MU-A12YV POWER CONSUMPTION (kw) Cooling AIRFLOW (m 3 /h) NOISE db(a) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R410A* (kg) PIPE SIZE Liquid ø (mm) Gas , 1, 50 RUNNING CURRENT (A) * Factory charged to 7 m pipe length, optional charging on page 25 The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below the unit in anechoic chamber 6
7 Series MS Cooling Only Wall Mounted Systems Energy-saving rotary piston compressor Compact indoor units - easy to install `Swing Mode -function enables automatically a more natural and comfortable airflow throughout the room Factory charged with refrigerant R410A Hand-held controller with `fuzzy logic control Remote control for five different angles of airflow direction Auto restart function 24 h Timer Long-life and washable Catechin filters for deodorising and prevention of bacteria and viruses Accessories: Additional filters available to keep air fresh, please view page 24 MS COOLING ONLY - WALL MOUNTED SYSTEMS INDOOR UNIT MS-A18WV MS-A24WV MS-A30WV CAPACITY (kw) Cooling AIRFLOW (m 3 /h) Low High NOISE db(a) Low High WEIGHT (kg) DIMENSIONS (mm) Width Depth Height , 1, 50 RUNNING CURRENT (A) OUTDOOR UNIT MU-A18WV MU-A24WV MU-A30WV POWER CONSUMPTION (KW) Cooling AIRFLOW (m 3 /h) NOISE db(a) WEIGHT (kg) DIMENSIONS (MM) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R410A* (kg) PIPE SIZE Liquid ø (mm) Gas , 1, 50 RUNNING CURRENT (A)) * Factory charged to 7 m pipe length, optional charging on page 25 The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below the unit in anechoic chamber 7
8 Series MSC Cooling/Heating Wall Mounted Systems True comfort year-round Compact indoor units - easy to install Extremely quiet operation with noise level of only 25 db(a)* `Swing Mode -function for a quick cooling and comfortable airflow throughout the room Energy-saving rotary piston compressor Factory charged with refrigerant R410A Hand-held controller with `fuzzy logic control Remote control for five different angles of airflow direction Auto restart function 24 h Timer Long-life and washable Catechin filters for deodorising and prevention of bacteria and viruses Accessories: Additional filters available to keep air fresh, please view page 24 * MSC-A07/09YV MSC COOLING/HEATING - WALL MOUNTED SYSTEMS INDOOR UNIT MSC-A07YV MSC-A09YV MSC-A12YV CAPACITY (kw) Cooling Heating AIRFLOW (m 3 /h) Low High NOISE db(a) Low High WEIGHT (kg) DIMENSIONS (mm) Width Depth Height , 1, 50 RUNNING CURRENT (A) OUTDOOR UNIT MUH-A07YV MUH-A09YV MUH-A12YV POWER CONSUMPTION (kw) Cooling Heating AIRFLOW (m 3 /h) NOISE db(a) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R410A* (kg) PIPE SIZE Liquid ø (mm) Gas , 1, 50 RUNNING CURRENT (A) * Factory charged to 7 m pipe length, optional charging on page 25 The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below the unit in anechoic chamber (cooling mode) 8
9 Series MSH Cooling/Heating Wall Mounted Systems True comfort year-round Compact indoor units - easy to install `Swing Mode -function for a quick cooling and comfortable airflow throughout the room Energy-saving rotary piston compressor Factory charged with refrigerant R410A Hand-held controller with `fuzzy logic control Remote control for five different angles of airflow direction Auto restart function 24 h Timer Long-life and washable Catechin filters for deodorising and prevention of bacteria and viruses Accessories: Additional filters available to keep air fresh, please view page 24 MSH COOLING/HEATING WALL MOUNTED SYSTEMS INDOOR UNIT MSH-A18WV MSH-A24WV MSH-A30WV CAPACITY (kw) Cooling Heating AIRFLOW (m 3 /h)) Low High NOISE db(a) Low High WEIGHT (kg) DIMENSIONS (mm) Width Depth Height , 1, 50 RUNNING CURRENT (A) OUTDOOR UNIT MUH-A18WV MUH-A24WV MUH-A30WV POWER Cooling CONSUMPTION (kw) Heating AIRFLOW (m 3 /h)) NOISE db(a) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R410A* (kg) PIPE SIZE Liquid ø (mm) Gas , 1, 50 RUNNING CURRENT (A) * Factory charged to 7 m pipe length, optional charging on page 25 The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below the unit in anechoic chamber (cooling mode) 9
10 Series MCF Cooling Only Floor or Ceiling Mounted Systems Versatile 2-in-1 design supplied with multi-purpose brackets for floor-standing or ceiling-suspension Hand-held controller with `fuzzy logic control Lightweight and compact design for easy installation Readily access for pipe connections and maintenance Quiet operation noise Adjustment of five different angles of airflow direction Three fan-stages or automatic set-up angles of airflow direction `Swing Mode -function for a quick cooling and comfortable airflow throughout the room Factory charged with refrigerant R410A Auto restart function 24 h Timer Accessories: Additional filters available to keep air fresh, please view page 24 MCF COOLING ONLY - FLOOR OR CEILING MOUNTED SYSTEMS INDOOR UNIT MCF-A12WV MCF-A18WV MCF-A24WV CAPACITY (kw) Cooling AIRFLOW (m 3 /h) Low High NOISE db(a) Low High WEIGHT (kg) DIMENSIONS (mm) Width Depth Height , 1, 50 RUNNING CURRENT (A) OUTDOOR UNIT MU-A12YV MUCF-A18WV MUCF-A24WV POWER CONSUMPTION (kw) Cooling AIRFLOW (m 3 /h) NOISE db(a) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HeightNDIFFERENZ (m) CHARGE R410A* (kg) PIPE SIZE Liquid ø (mm) Gas (V, PHASE,Hz) , 1, 50 RUNNING CURRENT (A) * Factory charged to 7 m pipe length, optional charging on page 25 The noise levels are measured at a position 1.0 m in front of and 0.8 m below (ceiling mounted) / 1.0 m below (floor standing) the unit in anechoic chamber 10
11 Series MCFH Cooling/Heating Floor or Ceiling Mounted Systems Versatile 2-in-1 design supplied with multi-purpose brackets for floor-standing or ceiling-suspension Lightweight and compact design for easy installation Comfortable temperature the whole year round Quiet operation noise Hand-held controller with fuzzy-logic control Adjustment of five different angles of airflow direction 24 h Timer Factory charged with refrigerant R410A Readily access for pipe connections and maintenance Three fan-stages or automatic set-up angles of airflow direction Accessories: Additional filters available to keep air fresh, please view page 24 MCFH COOLING/HEATING - FLOOR OR CEILING MOUNTED SYSTEMS INDOOR UNIT MCFH-A12WV MCFH-A18WV MCFH-A24WV CAPACITY (kw) Cooling Heating AIRFLOW(m 3 /h) Low Mittel High NOISE db(a) Low High WEIGHT (kg) DIMENSIONS (mm) Width Depth Height , 1, 50 RUNNING CURRENT (A) Cooling OUTDOOR UNIT MUH-A12YV MUCFH-A18WV MUCFH-A24WV POWER Cooling CONSUMPTION (kw) Heating AIRFLOW(m 3 /h) NOISE db(a) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R410A* (kg) PIPE SIZE Liquid ø (mm) Gas , 1, 50 RUNNING CURRENT (A) * Factory charged to 7 m pipe length, optional charging on page 25 The noise levels are measured at a position 1.0 m in front of and 0.8 m below (ceiling mounted) / 1.0 m below (floor standing) the unit in anechoic chamber 11
12 Series MSZ Inverter Single-Split Cooling/Heating Wall Mounted Systems Compact indoor units - easy to install Easy and quick cleaning with `Quick Clean Body -system Extremely quiet operation with noise level of only 21 db(a) (MSZ-A09YV) Energy-saving inverter technology provides highest comfort year-round `Swing Mode -function for a quick cooling and comfortable airflow throughout the room Factory charged with refrigerant R410A Hand-held controller with `fuzzy logic control Remote control for five different angles of airflow direction 24 h Timer Long-life and washable Catechin filters for deodorising and prevention of bacteria and viruses Winterkit in cooling mode up to -15 C, view page 5 Accessories: Additional filters available to keep air fresh, please view page 24 Quick clean kit for connection to household vacuum cleaner MSZ INVERTER SINGLE-SPLIT, COOLING/HEATING INDOOR UNIT MSZ-A09YV MSZ-A12YV CAPACITY (kw) Cooling 2.5 ( ) 3.5 ( ) Heating 3.2 ( ) 4.0 ( ) AIRFLOW (m 3 /h) Low High NOISE db(a) Low High WEIGHT (kg) 9 10 DIMENSIONS (mm) Width Depth Height , 1, 50 RUNNING CURRENT (A) OUTDOOR UNIT MUZ-A09YV MUZ-A12YV POWER Cooling ,09 CONSUMPTION (kw) Heating AIRFLOW(m 3 /h) NOISE db(a) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R410A* (kg) PIPE SIZE Liquid 6 6 ø (mm) Gas , 1, 50 RUNNING CURRENT (A) * Factory charged to 7 m pipe length, optional charging on page 25 The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below the unit in anechoic chamber (cooling mode) 12
13 Series MSZ Inverter Single-Split Cooling/Heating Wall Mounted Systems Compact indoor units - easy to install Easy and quick cleaning with `Quick Clean Body -system Energy-saving inverter technology provides highest comfort year-round `Swing Mode -function for a quick cooling and comfortable airflow throughout the room Factory charged with refrigerant R410A Hand-held controller with `fuzzy logic control Remote control for five different angles of airflow direction 24 h Timer Long-life and washable Catechin filters for deodorising and prevention of bacteria and viruses Winterkit in cooling mode up to -15 C, view page 5 Accessories: Additional filters available to keep air fresh, please view page 24 MSZ INVERTER SINGLE SPLIT, COOLING/HEATING INDOOR UNIT MSZ-A18YV MSZ-A24YV MSZ-A26YV CAPACITY (kw) Cooling 5.0 ( ) 6.0 ( ) 7.1 ( ) Heating 6.25 ( ) 7.0 ( ) 8.5 ( ) AIRFLOW (m 3 /h) Low High NOISE db(a) Low High WEIGHT (kg) DIMENSIONS (mm) Width Depth Height , 1, 50 RUNNING CURRENT (A) OUTDOOR UNIT MUZ-A18YV MUZ-A24YV MUZ-A26YV POWER Cooling ,35 CONSUMPTION (kw) Heating AIRFLOW (m 3 /h) NOISE db(a) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R410A* (kg) PIPE SIZE Liquid ø (mm) Gas (V, PHASE,Hz) , 1, 50 RUNNING CURRENT (A) * Factory charged to 7 m pipe length, optional charging on page 25 The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below the unit in anechoic chamber (cooling mode) Units available approx. July/August
14 Series SLZ Inverter Cooling/Heating In-Ceiling Cassette Systems The standardised Euro-spacing facilitates installation in existing inserted ceilings The required installation height is only 235 mm Quiet operation with noise level of only 32 db(a)* Low weight of 16.5 kg - easy to install Best airflow adjustment by three fan stages Long-life filters to keep air fresh, cleaning necessary only after 2,500 hours of normal operation Equipped with drain pump, delivery height 500 mm Fresh air intake Infrared controller with 12-hours on/off-timer Auto restart function Factory charged with R410A Winterkit in cooling mode up to -15 C, view page 5 * SLZ-A09AR SLZ INVERTER COOLING/HEATING - IN-CEILING CASSETTE SYSTEMS INDOOR UNIT SLZ-A09AR SLZ-A12AR SLZ-A18AR GRILLE SLP-2AL SLP-2AL SLP-2AL CAPACITY (kw) Cooling 2.5 ( ) 3.2 ( ) 4.3 ( ) Heating 3.0 ( ) 3.8 ( ) 4.8 ( ) AIRFLOW (m 3 /h) Low Middle High NOISE db(a) Low High WEIGHT (KG) (kg) 16.5/ / /19.5 DIMENSIONS (mm) Width Indoor unit Depth Height* DIMENSIONS (mm) Width Grille Depth Height** , 1, 50 RUNNING CURRENT (A) OUTDOOR UNIT SUZ-A09VR SUZ-A12VR SUZ-A18VR POWER Cooling CONSUMPTION (kw) Heating AIRFLOW (m 3 /h) NOISE db(a) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R410A*** (kg) PIPE SIZE Liquid ø (mm) Gas , 1, 50 RUNNING CURRENT (A) *** Required installation height *** Visible height of grille *** Factory charged to 7 m pipe length, optional charging on page 25 The noise levels are measured at a position 1.5 m below the unit in anechoic chamber (cooling mode) 14
15 Series SEZ Inverter Cooling/Heating Ceiling Concealed Systems Quiet operation of indoor and outdoor units Compact, easy-to-install design (only 270 mm height) Low power consumption for economy of use Direct driven, forward curved centrifugal fan for maximum air throw Self diagnostic trouble shooting function Air intake options for entry at back or base of indoor unit High quality remote control with service display and 12 h-timer Factory charged with refrigerant R410A Auto restart function Winterkit in cooling mode up to -15, view page 5 Air filters PAC-1000 FT included in delivery SEZ INVERTER COOLING/HEATING - CEILING CONCEALED SYSTEMS INDOOR UNIT SEZ-A12AR SEZ-A18AR SEZ-A24AR CAPACITY (kw) Cooling 3.4 ( ) 4.7 ( ) 5.4 ( ) Heating 3.9 ( ) 5.7 ( ) 6.5 ( ) AIRFLOW (m 3 /h) Low High EXTERNAL STATIC PRESSURE (Pa) 30 (50) 30 (50) 30 (50) NOISE db(a) Low High WEIGHT (kg) DIMENSIONS (mm) Width Depth Height , 1, 50 RUNNING CURRENT (A) OUTDOOR UNIT SUZ-A12VR SUZ-A18VR SUZ-A24VR POWER Cooling CONSUMPTION (kw) Heating AIRFLOW (m 3 /h) NOISE db(a) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE* R410A (kg) PIPE SIZE Liquid Ø (mm) Gas , 1, 50 RUNNING CURRENT (A) * Factory charged to 7 m pipe length, for further information please view page 25 The values given in the table for the noise level reflect the levels measured at a position 1.5 m below the unit in anechoic chamber 15
16 Series MSX Multi-Split Cooling Only Wall Mounted Systems Advantages: Cooling capacity between 2.8 kw and 7.3 kw per outdoor unit Up to four wall mounted indoor units with different capacity can be connected for cooling 2, 3 or 4 rooms Independent infrared controller with 24-hours on/off-timer Expandable system, units can be added at any time Multi-Split configurations provide greater economy and comfort due to quiet operation noise, MSC-A07/09 YV only 25 db(a) The energy-saving rotary compressor enables quiet economical performance Auto restart function Refrigerant R410A MSC WALL MOUNTED INDOOR UNITS INDOOR UNIT MSC-A07YV MSC-A09YV MSC-A12YV CAPACITY (kw) Cooling Depending on combinations, view pages AIRFLOW (m 3 /h) Low High NOISE db(a) Low High WEIGHT (kg) DIMENSIONS (mm) Width Depth Height* , 1, 50 RUNNING CURRENT (A) POWER CONSUMPTION (W) PIPE SIZE Liquid ø (mm) Gas COMBINATION WITH 2 WALL MOUNTED INDOOR UNITS: OUTDOOR UNIT MUX-A10WV MUX-A19WV MUX-A25WV CAPACITY (kw) Cooling CONNECTABLE INDOOR Number UNITS Type 2 x 07 1 x x 12 2 x 12 AIRFLOW (m 3 /h) NOISE db(a) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height TOTAL PIPE LENGTH (m) MAX. PIPE LENGTH per indoor unit (m) MAX. HEIGHT DIFFERENCE DIFFERENCE (m) COMPRESSORS (pc) CHARGE R410A (kg)* Quantity 0.90 (2 x 0.7) 1.0 (12) 0.95 (12) Apportionment 0.8 (07) 0.95 (12) Charge for (m) 10 (2 x 0.7) 7 (12) 7 (12) Apportionment 7 (07) 7 (12) PIPE SIZE Liquid 2 x 6 2 x 6 2 x 6 ø (mm) Gas 2 x 10 1 x 10/ 1 x 12 2 x 12 (V, Phase, Hz) , 1, 50 RUNNING CURRENT (A) POWER CONSUMPTION (kw) The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below the unit in anechoic chamber * The values in brackets refer to the connected indoor units MSC-A07/09/12YV, optional charging on page 25 16
17 Series MSX Multi-Split Systems Cooling Only - 2 Wall Mounted Indoor Units Twin Combination: MSX-A10WV 2.8 kw cooling capacity up to 2 connectable indoor units 2 x MSC-A07YV MSC-A07YV MUX-A10WV MSC-A07YV COOLING CAPACITY (kw) OPERATION INDOOR UNIT INDOOR UNIT MSC-A07YV MSC-A07YV 1 indoor unit indoor unit MSX-A19WV MSC-A12YV 5.9 kw cooling capacity up to two connectable indoor units 1 x MSC-A07YV 1 x MSC-A12YV MUX-A19WV MSC-A07YV COOLING CAPACITY (kw) OPERATION INDOOR UNIT INDOOR UNIT MSC-A12YV MSC-A07YV 1 indoor unit indoor unit MSX-A25WV 7.0 kw cooling capacity up to two connectable indoor units 2 x MSC-A12YV MSC-A12YV MUX-A25WV MSC-A12YV COOLING CAPACITY (kw) OPERATION INDOOR UNIT INDOOR UNIT MSC-A12YV MSC-A12YV 1 indoor unit indoor unit
18 Series MSX Multi-Split Systems Cooling Only - 3 or 4 Wall Mounted Indoor Units MSC WALL MOUNTED INDOOR UNITS INDOOR UNIT MSC-A07YV MSC-A09YV MSC-A12YV CAPACITY (kw) Cooling Depending on combinations, view pages AIRFLOW (m 3 /h) Low High NOISE db(a) Low High WEIGHT (kg) DIMENSIONS (mm) Width Depth Height , 1, 50 RUNNING CURRENT (A) POWER CONSUMPTION (W) PIPE SIZE Liquid ø (mm) Gas COMBINATION WITH 3 OR 4 WALL MOUNTED INDOOR UNITS: OUTDOOR UNIT MUX-A20WV MUX-A22WV MUX-A26WV CAPACITY (kw) Cooling CONNECTABLE INDOOR Number UNITS Type 3 x 09 2 x x 12 2 x x 12 AIRFLOW (m 3 /h) NOISE db(a) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height TOTAL PIPE LENGTH (m) MAX. PIPE LENGTH per indoor unit (m) MAX. HEIGHT DIFFERENCE (m) COMPRESSORS (pc) CHARGE R410A (kg)* Quantity 0.80 (09) 0.85 (12) 1.05 (2 x 09) Apportionment 1.0 (2 x 09) 0.85 (2 x 07) 1.05 (2 x 12) Charge for (m) 7 (09) 7 (12) 10 (2 x 09) Apportionment 10 (2 x 09) 10 (2 x 07) 10 (2 x 12) PIPE SIZE Liquid 3 x 6 3 x 6 4 x 6 ø (mm) Gas 3 x 10 2 x 10 / 1 x 12 2 x 10 / 2 x 12 (V, Phase, Hz) , 1, 50 RUNNING CURRENT (A) POWER CONSUMPTION incl. indoor units (kw) The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below the unit in anechoic chamber * The values in brackets refer to the connected indoor units MSC-A07/09/12YV, optional charging on page 25 18
19 TRIPLE COMBINATION: MSC-A09YV MSX-A20WV 6.0 kw cooling capacity up to 3 connectable indoor units 3 x MSC-A09YV MUX-A20WV MSC-A09YV MSC-A09YV COOLING CAPACITY (kw) OPERATION INDOOR UNIT INDOOR UNIT INDOOR UNIT MSC-A09YV MSC-A09YV MSC-A09YV 1 indoor unit indoor unit indoor unit MSC-A12YV MSX-A22WV 6.5 kw cooling capacity up to 3 connectable indoor units 1 x MSC-A12YV 2 x MSC-A07YV MUX-A22WV MSC-A07YV MSC-A07YV COOLING CAPACITY (kw) OPERATION INDOOR UNIT INDOOR UNIT INDOOR UNIT MSC-A12YV MSC-A07YV MSC-A07YV 1 indoor unit indoor unit indoor unit MSC-A12YV MSX-A26WV 7.3 kw cooling capacity up to 4 connectable indoor units 2 x MSC-A12YV 2 x MSC-A09YV MUX-A26WV MSC-A12YV MSC-A09YV MSC-A09YV COOLING CAPACITY (kw) OPERATION INDOOR UNIT INDOOR UNIT INDOOR UNIT INDOOR UNIT MSC-A12YV MSC-A12YV MSC-A09YV MSC-A09YV 1 indoor unit indoor unit indoor unit indoor unit
20 Series MXZ Inverter Multi-Split Systems Cooling/Heating Energy-saving inverter technology provides highest comfort year-round Very quiet operation Factory charged with R410A Can operate with up to four indoor units connected Various indoor units available: Wall mounted systems, floor or ceiling mounted systems, ceiling concealed system and in-ceiling cassette system Combination of indoor units with different capacity possible Special control retains customised temperature adjustment Auto restart function Winterkit in cooling mode up to -15 C*, view page 5 * for MXZ-A26/32 WV MXZ INVERTER MULTI-SPLIT SYSTEMS COOLING/HEATING OUTDOOR UNIT MXZ-A18WV MXZ-A26WV MXZ-A32WV CAPACITY (kw) Cooling 5.4 ( ) 7.2 ( ) 8.0 ( ) Heating 6.6 ( ) 9.0 ( ) 9.4 ( ) POWER CONSUMPTION Cooling 1.86 ( ) 2.09 ( ) 2.19 ( ) incl. indoor units (kw) Heating 1.77 ( ) 2.15 ( ) 1.93 ( ) AIRFLOW (m3/h) NOISE db(a) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH per indoor unit (m) TOTAL PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R410A* (kg) Pipe size Liquid 2 x 6 3 x 6 4 x 6 Ø (mm) Gas 2 x 10 1 x 12 / 2 x 10 2 x 12 / 2 x , 1, 50 RUNNING CURRENT (A) Cooling Heating * Factory charged for max. pipe lengths please view page 25 REMARK: The Multi-Split Systems run either cooling or heating mode. At least two indoor units have to be connected. Possible combinations on page 21, 22 and
21 Series MXZ Inverter Multi-Split Systems Cooling/Heating MXZ-A18WV Wall mounted systems: MSC-A07/09/12YV Floor or ceiling mounted systems: MCFH-A12WV Ceiling concealed systems: SEZ-A12AR In-ceiling cassette systems: SLZ-A09/12AR, SLP-2AL (Grille) Combination Mode Capacity (kw) Model A B TOTAL 07 Cooling / HEATING 2.30 / 3.30 / 2.3 ( ) / 3.30 ( ) 09 Cooling / HEATING 2.50 / 3.60 / 2.5 ( ) / 3.60 ( ) 12 Cooling / HEATING 3.40 / 4.00 / 3.4 ( ) / 4.00 ( ) Cooling / HEATING 2.30 / / ( ) / 6.10 ( ) Cooling / HEATING 2.30/ / ( ) / 6.20 ( ) Cooling / HEATING 2.02 / / ( ) / 6.50 ( ) Cooling / HEATING 2.50 / / ( ) / 6.50 ( ) Cooling / HEATING 2.20 / / ( ) / 6.55 ( ) Cooling / HEATING 2.65 / / ( ) / 6.60 ( ) COMBINATION EXAMPLES MXZ-A18WV - Please refer to the following table for permitted combinations MSC-A12YV SEZ-A12AR MXZ-A18WV SLZ-A09/12AR SLP-2AL (Grille) MCFH-A12WV MXZ-A18WV 21
22 MXZ-A26WV Wall mounted systems: Floor or ceiling mounted systems: Ceiling concealed systems: In-ceiling cassette systems: MSC-A07/09/12YV, MSH-A18/24WV MCFH-A12/18/24WV SEZ-A12/18/24AR SLZ-A09/12/18AR (grille SLP-2AL) Kombination Model Mode Capacity (kw) A B C Total 7 Cooling/Heating 2.3 / ( ) / 3.3 ( ) 9 Cooling/Heating 2.5 / ( ) / 3.6 ( ) 12 Cooling/Heating 3.4 / ( ) / 4.0 ( ) 18 Cooling/Heating 5.0 / ( ) / 7.2 ( ) 24 Cooling/Heating 6.0 / ( ) / 7.9 ( ) Cooling/Heating 2.3 / / ( ) / 6.6 ( ) Cooling/Heating 2.1 / / ( ) / 6.9 ( ) Cooling/Heating 2.1 / / ( ) / 7.3 ( ) Cooling/Heating 2.01 / / ( ) / 8.9 ( ) Cooling/Heating 1.62 / / ( ) / 9.0 ( ) Cooling/Heating 2.5 / / ( ) / 7.2 ( ) Cooling/Heating 2.52 / / ( ) / 7.6 ( ) Cooling/Heating 2.4 / / ( ) / 9.0 ( ) Cooling/Heating 1.96 / / ( ) / 9.0 ( ) Cooling/Heating 3.4 / / ( ) / 8.0 ( ) Cooling/Heating 2.88 / / ( ) / 9.0 ( ) Cooling/Heating 2.4 / / ( ) / 9.0 ( ) Cooling/Heating 3.6 / / ( ) / 9.0 ( ) Cooling/Heating 3.08 / / ( ) / 9.0 ( ) Cooling/Heating 2.3 / / / ( ) / 8.7 ( ) Cooling/Heating 2.16 / / / ( ) / 8.8 ( ) Cooling/Heating 1.93 / / / ( ) / 9.0 ( ) Cooling/Heating 1.58 / / / ( ) / 9.0 ( ) Cooling/Heating 1.32 / / / ( ) / 9.0 ( ) Cooling/Heating 2.01 / / / ( ) / 9.0 ( ) Cooling/Heating 1.8 / / / ( ) / 9.0 ( ) Cooling/Heating 1.48 / / / ( ) / 9.0 ( ) Cooling/Heating 1.26 / / / ( ) / 9.0 ( ) Cooling/Heating 1.62 / / / ( ) / 9.0 ( ) Cooling/Heating 1.36 / / / ( ) / 9.0 ( ) Cooling/Heating 1.17 / / / ( ) / 9.0 ( ) Cooling/Heating 1.17 / / / ( ) / 9.0 ( ) Cooling/Heating 1.02 / / / ( ) / 9.0 ( ) Cooling/Heating 2.36 / / / ( ) / 9.0 ( ) Cooling/Heating 2.16 / / / ( ) / 9.0 ( ) Cooling/Heating 1.8 / / / ( ) / 9.0 ( ) Cooling/Heating 1.45 / / / ( ) / 9.0 ( ) Cooling/Heating 1.97 / / / ( ) / 9.0 ( ) Cooling/Heating 1.66 / / / ( ) / 9.0 ( ) Cooling/Heating 1.44 / / / ( ) / 9.0 ( ) Cooling/Heating 1.44 / / / ( ) / 9.0 ( ) Cooling/Heating 1.27 / / / ( ) / 9.0 ( ) Cooling/Heating 2.4 / / / ( ) / 9.0 ( ) Cooling/Heating 2.05 / / / ( ) / 9.0 ( ) Cooling/Heating 1.8 / / / ( ) / 9.0 ( ) Cooling/Heating 1.8 / / / ( ) / 9.0 ( ) Cooling/Heating 1.6 / / / ( ) / 9.0 ( ) 22
23 MXZ-A32WV Wall mounted systems: Combination Model Model Capacity (kw) MSC-A07/09/12YV, MSH-A18/24WV Floor or ceiling mounted systems: MCFH-A12/18/24WV Ceiling concealed systems: SEZ-A12/18/24AR In-ceiling cassette systems: SLZ-A09/12/18AR (grille SLP-2AL) Cooling/Heating A B C D Total 7 Cooling/Heating 2.3 / ( ) / 3.3 ( ) 9 Cooling/Heating 2.5 / ( ) / 3.6 ( ) 12 Cooling/Heating 3.4 / ( ) / 4.0 ( ) 18 Cooling/Heating 5.0 / ( ) / 7.2 ( ) 24 Cooling/Heating 6.0 / ( ) / 7.9 ( ) Cooling/Heating 2.3 / / ( ) / 6.6 ( ) Cooling/Heating 2.1 / / ( ) / 6.9 ( ) Cooling/Heating 2.1 / / ( ) / 7.3 ( ) Cooling/Heating 2.04 / / ( ) / 8.9 ( ) Cooling/Heating 1.75 / / ( ) / 9.4 ( ) Cooling/Heating 2.5 / / ( ) / 7.2 ( ) Cooling/Heating 2.52 / / ( ) / 7.6 ( ) Cooling/Heating 2.5 / / ( ) / 9.0 ( ) Cooling/Heating 2.11 / / ( ) / 9.4 ( ) Cooling/Heating 3.4 / / ( ) / 8.0 ( ) Cooling/Heating 3.1 / / ( ) / 9.4 ( ) Cooling/Heating 2.61 / / ( ) / 9.4 ( ) Cooling/Heating 3.95 / / ( ) / 9.4 ( ) Cooling/Heating 3.42 / / ( ) / 9.4 ( ) Cooling/Heating 4.0 / / ( ) / 9.4 ( ) Cooling/Heating 2.3 / / / ( ) / 8.7 ( ) Cooling/Heating 2.16 / / / ( ) / 8.8 ( ) Cooling/Heating 2.07 / / / ( ) / 9.4 ( ) Cooling/Heating 1.72 / / / ( ) / 9.4 ( ) Cooling/Heating 1.46 / / / ( ) / 9.4 ( ) Cooling/Heating 2.04 / / / ( ) / 8.9 ( ) Cooling/Heating 1.93 / / / ( ) / 9.4 ( ) Cooling/Heating 1.62 / / / ( ) / 9.4 ( ) Cooling/Heating 1.4 / / / ( ) / 9.4 ( ) Cooling/Heating 1.77 / / / ( ) / 9.4 ( ) Cooling/Heating 1.49 / / / ( ) / 9.4 ( ) Cooling/Heating 1.3 / / / ( ) / 9.4 ( ) Cooling/Heating 1.3 / / / ( ) / 9.4 ( ) Cooling/Heating 1.14 / / / ( ) / 9.4 ( ) Cooling/Heating 2.36 / / / ( ) / 9.0 ( ) Cooling/Heating 2.32 / / / ( ) / 9.4 ( ) Cooling/Heating 1.97 / / / ( ) / 9.4 ( ) Cooling/Heating 1.71 / / / ( ) / 9.4 ( ) Cooling/Heating 2.15 / / / ( ) / 9.4 ( ) Cooling/Heating 1.84 / / / ( ) / 9.4 ( ) Cooling/Heating 1.6 / / / ( ) / 9.4 ( ) Cooling/Heating 1.6 / / / ( ) / 9.4 ( ) Cooling/Heating 1.41 / / / ( ) / 9.4 ( ) Cooling/Heating 2.65 / / / ( ) / 9.4 ( ) Cooling/Heating 2.28 / / / ( ) / 9.4 ( ) Cooling/Heating 2.0 / / / ( ) / 9.4 ( ) Cooling/Heating 2.0 / / / ( ) / 9.4 ( ) Cooling/Heating 1.77 / / / ( ) / 9.4 ( ) Cooling/Heating 1.95 / / / / ( ) / 9.4 ( ) Cooling/Heating 1.83 / / / / ( ) / 9.4 ( ) Cooling/Heating 1.68 / / / / ( ) / 9.4 ( ) Cooling/Heating 1.43 / / / / ( ) / 9.4 ( ) Cooling/Heating 1.24 / / / / ( ) / 9.4 ( ) Cooling/Heating 1.72 / / / / ( ) / 9.4 ( ) Cooling/Heating 1.59 / / / / ( ) / 9.4 ( ) Cooling/Heating 1.36 / / / / ( ) / 9.4 ( ) Cooling/Heating 1.19 / / / / ( ) / 9.4 ( ) Cooling/Heating 1.47 / / / / ( ) / 9.4 ( ) Cooling/Heating 1.27 / / / / ( ) / 9.4 ( ) Cooling/Heating 1.12 / / / / ( ) / 9.4 ( ) Cooling/Heating 1.12 / / / / ( ) / 9.4 ( ) Cooling/Heating 1.62 / / / / ( ) / 9.4 ( ) Cooling/Heating 1.5 / / / / ( ) / 9.4 ( ) Cooling/Heating 1.3 / / / / ( ) / 9.4 ( ) Cooling/Heating 1.14 / / / / ( ) / 9.4 ( ) Cooling/Heating 1.4 / / / / ( ) / 9.4 ( ) Cooling/Heating 1.21 / / / / ( ) / 9.4 ( ) Cooling/Heating 1.07 / / / / ( ) / 9.4 ( ) Cooling/Heating 1.3 / / / / ( ) / 9.4 ( ) Cooling/Heating 1.14 / / / / ( ) / 9.4 ( ) Cooling/Heating 1.97 / / / / ( ) / 9.4 ( ) Cooling/Heating 1.84 / / / / ( ) / 9.4 ( ) Cooling/Heating 1.6 / / / / ( ) / 9.4 ( ) Cooling/Heating 1.41 / / / / ( ) / 9.4 ( ) Cooling/Heating 1.56 / / / / ( ) / 9.4 ( ) Cooling/Heating 1.5 / / / / ( ) / 9.4 ( ) Cooling/Heating 1.6 / / / / ( ) / 9.4 ( ) Cooling/Heating 2.0 / / / / ( ) / 9.4 ( ) 23
24 Series Accessories AIR CLEANING FILTER MODEL REFERENCE QUANTITY APPLICABLE MODELS MAC-1300FT 10 MSC-A07/09/12YV MSZ-A09/12YV MAC-1700FT 10 MS(H)-A18/24/30WV MAC-1200FT 10 MCF/MCFH DEODORISING FILTER MODEL REFERENCE QUANTITY APPLICABLE MODELS MAC-1700DF 10 MCF/MCFH QUICK CLEAN KIT MODEL REFERENCE QUANTITY APPLICABLE MODELS MAC-093SS-E1 1 MSZ-A09/12YV Series Refrigerant Charge OUTDOOR UNITS with R410A Mostly factory charged to 7 m pipe length (one-way). Please view the required refrigerant charge for other pipe lengths in the following table. MU-A07/09/12/18/24/30YV/WV OUTDOOR UNITS CHARGE (ONE-WAY) in kg (MODELS) 7 m 10 m 15 m 20 m 25 m 30 m MU-A07YV MU-A09YV MU-A12YV MU-A18WV MU-A24WV MU-A30WV MUH-A07/09/12/18/24/30YV/WV OUTDOOR UNITS CHARGE (ONE-WAY) in kg (MODELS) 7 m 10 m 15 m 20 m 25 m 30 m MUH-A07YV MUH-A09YV MUH-A12YV MUH-A18WV MUH-A24WV MUH-A30WV MUCFH-A18/24WV OUTDOOR UNITS CHARGE (ONE-WAY) in kg (MODELS) 7 m 10 m 15 m 20 m 25 m MUCFH-A18WV MUCFH-A24WV
25 Series Refrigerant Charge MUZ-A09/12/18/24/26 YV OUTDOOR UNITS CHARGE (ONE-WAY) in kg (MODELS) 7 m 10 m 15 m 20 m 25 m 30 m MUZ-A 09 YV MUZ-A 12 YV MUZ-A 18 YV MUZ-A 24 YV MUZ-A 26 YV SUZ-A09/12/18YV OUTDOOR UNITS CHARGE (ONE-WAY) in kg (MODELS) 7 m 10 m 15 m 20 m 25 m 30 m SUZ-A 09 YV SUZ-A 12 YV SUZ-A 18 YV MUX-A10/19/25/20/22/26WV OUTDOOR UNITS Com- Indoor Units CHARGE (ONE-WAY) in kg (MODELS) pressor Models 7 m 10 m 15 m 20 m 25 m 30 m MUX-A10WV 1 2 X MSC-A07YV 0.900* MUX-A19WV 1 1 X MSC-A12YV 1.000* X MSC-A09YV 0.800* MUX-A25WV 1 1 X MSC-A12YV 0.950* X MSC-A12YV 0.950* MUX-A20WV 1 1 X MSC-A09YV 0.800* X MSC-A09YV 1.000* MUX-A22WV 1 1 X MSC-A12YV 0.850* 0.910* X MSC-A07YV 0.850* MUX-A26WV 1 2 X MSC-A09YV 1.050* X MSC-A12YV 1.050* * Factory charged MXZ-A18/26/32WV OUTDOOR UNITS CHARGE (ONE-WAY) in kg (MODELS) 20 m 25 m 30 m 40 m 50 m 60 m 70 m MXZ-A18WV MXZ-A26WV MXZ-A32WV
26 Mr. Slim Series Split- and Multi-Split Systems, R407C Cooling 3.15 kw kw The Mr. Slim Series offers a huge choice of components and configurations for a wide range of applications. The packaged air conditioners are adapted for middlesized rooms, shops, restaurants and offices - for cooling only or with heat pump-function. With ceiling cassettes, ceiling suspended units, wall mounted units and ceiling ducted units, there is a Mr. Slim model which provides the optimum fit for your next job. 26
27 Advantages of Mr. Slim Wide range of indoor units Simultaneous operation of 2, 3 or 4 indoor units Standard long-life filters Auto change over between cooling and heating mode Heat pump with warm start system Indoor units without electrical heater connectable to heat pump outdoor units A-Control makes servicing easier. Automatic switching between heating and cooling is available on heat pump units. Error codes are shown at remote controls display of indoor units. Wired or infrared remote controller optional Maintenance Tool for control and service All models can be interfaced to Building Management Systems by Lon Works Interface Lossnay heat exchange ventilators connectable Factory charged with R407C Winter kit as standard, cooling up to -15 Rating conditions Mr. Slim Series* R407C: Cooling Indoor: 19 C - 35 C DB 15 C C WB Outdoor: -15 C - 46 C DB Heating Indoor: 17 C - 28 C DB Outdoor: -11 C - 24 C DB -12 C - 18 C WB * For PUH-P8/10MYA other rating conditions, please view page 61 COOLING ONLY PMH 1-WAY-IN-CEILING CASSETTE SYSTEMS PLA COMPACT 4-WAY-IN-CEILING CASSETTE SYSTEMS PLA 4-WAY-IN-CEILING CASSETTE SYSTEMS PCA CEILING SUSPENDED SYSTEMS PCA CEILING SUSPENDED SYSTEMS FOR KITCHEN APPLICATIONS PKA WALL MOUNTED SYSTEMS PSA FLOORSTANDING UNITS PEAD CEILING CONCEALED SYSTEMS HEAT PUMP UNITS - COOLING AND HEATING PMH 1-WAY-IN-CEILING CASSETTE SYSTEMS PLA/PLH COMPACT 4-WAY-IN-CEILING CASSETTE SYSTEMS PLA/PLH 4-WAY-IN-CEILING CASSETTE SYSTEMS PCA/PCH CEILING SUSPENDED SYSTEMS PCA CEILING SUSPENDED SYSTEMS FOR KITCHEN APPLICATIONS PKA/PKH WALL MOUNTED SYSTEMS PSA/PSH FLOORSTANDING UNITS PEAD/PEHD CEILING CONCEALED SYSTEMS PEH CEILING CONCEALED SYSTEMS
28 Mr. Slim Series PMH Cooling Only 1-Way-In-Ceiling Cassette Systems Simple installation and service, because of compact dimensions installation height only 230 mm Wired remote control Precisely directed airflow to prevent dirt built-up and staining of ceiling tiles Standard long-life filter Simple installation and easy access drain and refrigerant piping connections Factory charged with R407C Rotary and scroll compressors Twin, triple and quadruple configuration possible Standard drain pump for 600 mm height differences External airflow prepared 4 fan-stages for comfortable and optimum airflow Accessories: Optional parts on page 70 and the following 28
29 PMH 1-WAY-IN-CEILING CASSETTE SYSTEMS COOLING ONLY INDOOR UNIT PMH-P1.6 BA PMH-P2 BA CAPACITY (kw) Cooling AIRFLOW (m 3 /h) Low Middle Middle High NOISE db(a) Low High WEIGHT incl. Grille (kg) 14/17 14/17 DIMENSIONS (mm) Width Indoor unit Depth Height* DIMENSIONS (mm) Width Grille Depth Height** , 1, , 1, 50 RUNNING CURRENT (A) Cooling OUTDOOR UNIT PU-P1.6 YGAA PU-P2 YGAA POWER CONSUMPTION (kw) Cooling AIRFLOW (m 3 /h) NOISE db(a) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C*** (kg) PIPE SIZE Liquid ø (mm) Gas , 3, , 3, 50 RUNNING CURRENT (A) Cooling *** Required installation height *** Visible height of grille *** Factory charged to 20 m pipe length, optional charging please view page 73 The noise levels are measured at a position 1.5 m below the unit in anechoic chamber. Outdoor units PU-P1.6/2 YGAA also available in V, 1Ph, 50 Hz 29
30 Mr. Slim Series PLA Cooling Only 4-Way-In-Ceiling Cassette Systems Wired remote control with 24h-timer Compact dimensions Simple installation with easy access drain and refrigerant piping connections Adjustable air outlets for optimum airflow for ceiling heights up to 3.8 m Precisely directed airflow to prevent dirt built-up and staining of ceiling tiles Rotary and scroll compressors Factory charged with R407C Long-life air filter Drain pump for 500 mm height difference Twin, triple, quadruple configuration possible, on page 72 Accessories: Space panel enables installation into ceiling void of just 258 mm depth Infrared remote control High efficiency filter and external airflow For detailed descriptions please view on page 70 and the following 30
31 Optional PLA 4-WAY-IN-CEILING CASSETTE SYSTEMS COOLING ONLY INDOOR UNIT PLA-P1.6 KA PLA-P2 KA PLA-P2.5 KA CAPACITY (kw) Cooling AIRFLOW (m 3 /h) Low Middle Middle High NOISE db(a) Low High WEIGHT incl. Grille (kg) 19 / / / 23.7 DIMENSIONS (mm) Width Indoor unit Depth Height* DIMENSIONS (mm) Width (Grille) Depth Height** , 1, , 1, , 1, 50 RUNNING CURRENT (A) Cooling OUTDOOR UNIT PU-P1.6 YGAA PU-P2 YGAA PU-P2.5 YGAA POWER CONSUMPTION (kw) Cooling AIRFLOW (m 3 /h) NOISE db(a) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C*** (kg) PIPE SIZE Liquid ø (mm) Gas , 3, , 3, , 3, 50 RUNNING CURRENT (A) Cooling GRILLE-TYPE FOR WIRED REMOTE CONTROL GRILLE-TYPE FOR INFRARED REMOTE CONTROL PLP-2.5 KC PLP-2.5 KLM *** Required installation height *** Visible height of grille *** Factory charged to 20 m pipe length, for further information please view page 73 The noise levels are measured at a position 1.5 m below the unit in anechoic chamber. Outdoor units PU-P1.6/2 YGAA also available in V, 1Ph, 50 Hz 31
32 Mr. Slim Series PLA Cooling Only 4-Way-In-Ceiling Cassette Systems Wired remote control or infrared remote control with 24h-timer Compact dimensions Extremely quiet operation noise, PLA-P3AA just 28 db(a) Weight reduced for PLA-P6AA from 46 kg to only 37 kg Great convenience due to four fan-stages Drain pump for 850 mm height difference Simple installation with easy access drain and refrigerant piping connections Adjustable air outlets for optimum airflow for ceiling heights up to 4.2 m Precisely directed airflow to prevent dirt built-up and staining of ceiling tiles Rotary and scroll compressors Factory charged with R407C Long-life air filter Twin, triple, quadruple configuration possible, on page 72 Accessories: Space panel enables installation into ceiling void of just 258 mm depth High efficiency filter and external airflow For detailed descriptions please view on page 70 and the following 32
33 PLA 4-WAY-IN-CEILING CASSETTE SYSTEMS COOLING ONLY INDOOR UNIT PLA-P3 AA PLA-P4 AA PLA-P5 AA PLA-P6 AA CAPACITY (kw) Cooling AIRFLOW (m 3 /h) Low Middle Middle High NOISE db(a) Low High WEIGHT incl. Grille (kg) 24/29 30/35 30/35 32/37 DIMENSIONS (mm) Width Indoor unit Depth Height* DIMENSIONS (mm) Width (Grille) Depth Height** (V, phase, Hz) , 1, , 1, , 1, , 1, 50 RUNNING CURRENT (A) Cooling OUTDOOR UNIT PU-P3 YGAA PU-P4 YGAA PU-P5 YGAA PU-P6 YGAA POWER CONSUMPTION (kw) Cooling AIRFLOW (m 3 /h) NOISE db(a) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C*** (kg) PIPE SIZE Liquid ø (mm) Gas , 3, , 3, , 3, , 3, 50 RUNNING CURRENT (A) Cooling GRILLE-TYPE FOR WIRED REMOTE CONTROL GRILLE-TYPE FOR INFRARED REMOTE CONTROL PLP-6 AAM PLP-6 AALM *** Required installation height *** Visible height of grille *** Factory charged to 30 m pipe length, for further information please view page 73 The noise levels are measured at a position 1.5 m below the unit in anechoic chamber. 33
34 Mr. Slim Series PCA Cooling Only Ceiling Suspended Systems Wired remote control with 24h-timer Adjustable air outlets for optimum airflow for ceiling heights up to 3.5 m Rotary and scroll compressors Factory charged with R407C Long-life air filter Great convenience due to four fan-stages Swing louvres with `Auto Angle airflow Twin, triple, quadruple configuration possible, on page 72 Accessories: High efficiency filter Drain pump Infrared remote control For detailed descriptions please view on page 70 and the following 34
35 Optional PCA CEILING SUSPENDED SYSTEMS COOLING ONLY INDOOR UNIT PCA-P2 GA PCA-P2.5 GA PCA-P3 GA PCA-P4 GA PCA-P5 GA PCA-P6 GA CAPACITY (kw) Cooling AIRFLOW (m 3 /h) Low Middle Middle High NOISE db(a) Low High WEIGHT (kg) DIMENSIONS (mm) Width Depth Height , 1, , 1, , 1, , 1, , 1, , 1, 50 RUNNING CURRENT (A) Cooling OUTDOOR UNIT PU-P2 YGAA PU-P2.5 YGAA PU-P3 YGAA PU-P4 YGAA PU-P5 YGAA PU-P6 YGAA POWER CONSUMPTION (kw) Cooling AIRFLOW (m 3 /h) NOISE db(a) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C* (kg) PIPE SIZE Liquid ø (mm) Gas , 3, , 3, , 3, , 3, , 3, , 3, 50 RUNNING CURRENT (A) Cooling * Factory charged to 20 m pipe length, PU-P3/P4/P5/P6 YGAA factory charged to 30 m pipe length, please also view page 73 The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber. 35
36 Mr. Slim Series PCA Cooling Only Ceiling Suspended Systems For Applications In Kitchens The established ceiling suspended system consisting of stainless steel for applications in kitchens The special construction enables easy cleaning of the casing and of all airflow parts Oil particles can be filtered 1.5 times more efficient compared to conventional types due to high performance filter (optional) On the rear panel round knockout opening (Ø 200 mm) allows more comfort by supplying fresh air Rotary and scroll compressors Factory charged with R407C Wired remote control with 24h-timer Twin configuration possible, on page 72 Accessories: Oil mist filter (12 pcs.) PAC-SG 38 KF-E For detailed descriptions please view on page 70 and the following 36
37 PCA CEILING SUSPENDED SYSTEMS COOLING ONLY INDOOR UNIT PCA-P3HA PCA-P5HA CAPACITY (kw) Cooling AIRFLOW (m 3 /h) Low High NOISE db(a) Low High WEIGHT (kg) DIMENSIONS (mm) Width Depth Height , 1, , 1, 50 RUNNING CURRENT (A) OUTDOOR UNIT PU-P3YGAA PU-P5YGAA POWER CONSUMPTION (kw) Cooling AIRFLOW (m 3 /h) NOISE db(a) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C* (kg) PIPE SIZE Liquid ø (mm) Gas , 3, , 3, 50 RUNNING CURRENT (A) Cooling * Factory charged to 30 m pipe length, for further information please view page 73 The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber. 37
38 Mr. Slim Series PKA Cooling Only Wall Mounted Systems Infrared remote control with 24h-timer Slim compact units for wall mounting Simple installation with easy access drain and refrigerant piping connections Rotary and scroll compressors Factory charged with R407C Easily removable long-life air filter PKA-P1.6/2 GAL with four fan-stages Swing louvres with Auto Angle airflow Twin, triple, quadruple configuration possible, on page 72 Accessories: Drain pump Wired remote control For detailed descriptions please view on page 70 and the following 38
39 Optional PKA WALL MOUNTED SYSTEMS COOLING ONLY INDOOR UNIT PKA-P1.6 GAL PKA-P2 GAL PKA-P2.5 FAL PKA-P3 FAL PKA-P4 FAL CAPACITY (kw) Cooling AIRFLOW (m 3 /h) Low Middle Middle High NOISE db(a) Low High WEIGHT (kg) DIMENSIONS (mm) Width Depth Height , 1, , 1, , 1, , 1, , 1, 50 RUNNING CURRENT (A) Cooling OUTDOOR UNIT PU-P1.6 YGAA PU-P2 YGAA PU-P2.5 YGAA PU-P3 YGAA PU-P4 YGAA POWER CONSUMPTION (kw) Cooling AIRFLOW (m 3 /h) NOISE db(a) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C* (kg) PIPE SIZE Liquid ø (mm) Gas , 3, , 3, , 3, , 3, , 3, 50 RUNNING CURRENT (A) Cooling * Factory charged to 20 m pipe length, PU-P3/4 YGAA factory charged to 30 m pipe length, please also view page 73 The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber. 39
40 Mr. Slim Series PSA Cooling Only Floorstanding units Function panel case integrated 24h-timer Simple installation with easy access drain and refrigerant piping connections Rotary and scroll compressors Factory charged with R407C Standard long-life filter Twin and triple configuration possible, on page 72 Accessories: Optional parts on page 70 and the following 40
41 PSA FLOORSTANDING UNITS COOLING ONLY INDOOR UNIT PSA-P3 GA PSA-P4 GA PSA-P5 GA PSA-P6 GA CAPACITY (kw) Cooling AIRFLOW (m 3 /h) Low High NOISE db(a) Low High WEIGHT (kg) DIMENSIONS (mm) Width Depth Height , 1, , 1, , 1, , 1, 50 RUNNING CURRENT (A) Cooling OUTDOOR UNIT PU-P3 YGAA PU-P4 YGAA PU-P5 YGAA PU-P6 YGAA POWER CONSUMPTION (kw) Cooling AIRFLOW (m 3 /h) NOISE db(a) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C* (kg) PIPE SIZE Liquid ø (mm) Gas , 3, , 3, , 3, , 3, 50 RUNNING CURRENT (A) Cooling * Factory charged to 30 m pipe length, please also view page 73 The noise levels are measured at a position 1 m in front of and 1 m above. 41
42 Mr. Slim Series PEAD Cooling Only Above-Ceiling Concealed Ducted Systems Wired remote control with 24h-timer Simple installation with easy access drain and refrigerant piping connections PEAD-P1.6/2/2.5 EA airflow variable - draw in from the back or underside Rotary and scroll compressors Factory charged with R407C Standard long-life filter Twin, triple, quadruple configuration possible, on page 72 Accessories: Drain pump Fan motor (external static pressure 130 Pa) For detailed descriptions please view on page 70 and the following 42
43 PEAD ABOVE-CEILING CONCEALED DUCTED SYSTEMS COOLING ONLY INDOOR UNIT PEAD-P1.6EA PEAD-P2EA PEAD-P2.5EA PEAD-P3EA PEAD-P4EA PEAD-P5EA PEAD-P6EA CAPACITY (kw) Cooling AIRFLOW (m 3 /h) Low High EXTERNAL STATIC PRESSURE (Pa) 30(70) 30(70) 30(70) 70(130**) 70(130**) 70(130**) 70(130**) NOISE db(a) Low 34(36) 36(38) 37(39) 37(40) 41(42) 44(46) 46(47) High 38(43) 40(44) 41(46) 41(45) 46(48) 50(52) 51(53) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height , 1, , 1, , 1, , 1, , 1, , 1, , 1, 50 RUNNING CURRENT (A) Cooling OUTDOOR UNIT PU-P1.6YGAA PU-P2YGAA PU-P2.5YGAA PU-P3YGAA PU-P4YGAA PU-P5YGAA PU-P6YGAA POWER CONSUMPTION (kw) Cooling AIRFLOW (m 3 /h) NOISE db(a) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C* (kg) PIPE SIZE Liquid ø (mm) Gas , , 3, , 3, , 3, , 3, , 3, , 3, 50 RUNNING CURRENT (A) Cooling ** Factory charged to 20 m pipe length, PU-P3/P4/P5/P6 YGAA factory charged to 30 m pipe length, please also view page 73 ** Fan motor optional on page 70 The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber. 43
44 Mr. Slim Series PMH Cooling / Heating 1-Way-In-Ceiling Cassette Systems Simple installation and service because of compact dimensions - installation height only 230 mm Wired remote control with 24h-timer Quiet operation - only 29 db(a) at PMH-P1 BA Precisely directed airflow to prevent dirt built-up and staining of ceiling tiles Standard long-life filter Easy access drain and refrigerant piping connections Factory charged with R407C Rotary and scroll compressors Drain pump for 600 mm height difference External airflow prepared 4 fan-stages for comfortable and optimum airflow Accessories: Optional parts on page 70 and the following 44
45 PMH 1-WAY-IN-CEILING CASSETTE SYSTEMS COOLING / HEATING INDOOR UNIT PMH-P1 BA PMH-P1.6 BA PMH-P2 BA CAPACITY (kw) Cooling Heating AIRFLOW (m 3 /h) Low Middle Middle High NOISE db(a) Low High WEIGHT incl. Grille (kg) 14/17 14/17 14/17 DIMENSIONS (mm) Width Indoor unit Depth Height* DIMENSIONS (mm) Width Grille Depth Height** , 1, , 1, , 1, 50 RUNNING CURRENT (A) Cooling Heating OUTDOOR UNIT PUH-P1 VGAA PUH-P1.6 YGAA PUH-P2 YGAA POWER Cooling CONSUMPTION (kw) Heating AIRFLOW (m 3 /h) NOISE db(a) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C*** (kg) PIPE SIZE Liquid ø (mm) Gas , 1, , 3, , 3, 50 RUNNING CURRENT (A) Cooling Heating GRILLE-TYPE FOR WIRED REMOTE CONTROL PMP-40 BM *** Required installation height *** Visible installation height *** Factory charged to 20 m pipe length, for further information please view page 73 The noise levels are measured at a position 1.5 m below the unit in anechoic chamber. Outdoor units PUH-P1.6/2 YGAA also available in V, 1Ph, 50 Hz 45
46 Mr. Slim Series PLA Cooling / Heating PLH Cooling / Heating 4-Way-In-Ceiling Cassette Systems Wired remote control with 24h-timer PLH units with additional electrical heating for a warm start and to increase capacity of heat pump 4 fan-stages for best comfort Precisely directed airflow to prevent dirt built-up and staining of ceiling tiles Adjustable air outlets for optimum airflow for ceiling heights up to 3.8 m Standard long-life filter Simple installation with easy access drain and refrigerant piping connections Rotary and scroll compressors Factory charged with R407C Drain pump for 500 mm height difference Twin, triple, quadruple configuration possible, on page 72 Accessories: Space panel enables installation into ceiling void of just 258 mm depth Infrared remote control High efficiency filter and external airflow For detailed descriptions please view on page 70 and the following 46
47 Optional PLA/PLH 4-WAY-IN-CEILING CASSETTE SYSTEMS COOLING / HEATING INDOOR UNIT PLA-P1.6 KA PLA-P2 KA PLA-P2.5 KA INDOOR UNIT WITH ELECTRICAL HEATING PLH-P1.6 KAH PLH-P2 KAH PLH-P2.5 KAH CAPACITY (kw) Cooling Heating* 5.0 (6.4) 6.0 (7.4) 7.4 (9.5) AIRFLOW (m 3 /h) Low Middle Middle High NOISE db(a) Low High WEIGHT PLA incl. Grille (kg) 19 / / / 23.7 WEIGHT PLH incl. Grille (kg) 20 / / / 24.7 DIMENSIONS (mm) Width Indoor unit Depth Height** DIMENSIONS (mm) Width Grille Depth Height*** , 1, , 1, , 1, 50 RUNNING CURRENT (A) Cooling Heating* 0.45 (5.83) 0.45 (5.83) 0.45 (8.75) OUTDOOR UNIT PUH-P1.6 YGAA PUH-P2 YGAA PUH-P2.5 YGAA POWER CONSUMPTION (kw) Cooling Heating* 1.9 (3.3) 2.4 (3.8) 2.6 (4.7) AIRFLOW (m 3 /h) NOISE db(a) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C**** (kg) PIPE SIZE Liquid ø (mm) Gas , 3, , 3, , 3, 50 RUNNING CURRENT (A) Cooling Heating GRILLE-TYPE FOR WIRED REMOTE CONTROL GRILLE-TYPE FOR INFRARED REMOTE CONTROL PLP-2.5 KC PLP-2.5 KLM **** Values given in brackets incl. additional electrical heating **** Required installation height **** Visible height of grille **** Factory charged to 30 m pipe length, optional charging on page 73 The noise levels are measured at a position 1.5 m below the unit in anechoic chamber. Outdoor units PUH-P1.6/2 YGAA also available in V, 1Ph, 50 Hz 47
48 Mr. Slim Series PLA Cooling / Heating PLH Cooling / Heating 4-Way-In-Ceiling Cassette Systems Wired remote control or infrared remote control with 24h-timer PLH units with additional electrical heating for a warm start and to increase capacity of heat pump Compact dimensions Extremely quiet operation noise, PLA-P3AA just 28 db(a) Weight reduced for PLA-P6AA from 46 kg to only 37 kg 4 fan-stages for best comfort Drain pump for 850 mm height difference Simple installation with easy access drain and refrigerant piping connections Adjustable air outlets for optimum airflow for ceiling heights up to 4.2 m Precisely directed airflow to prevent dirt built-up and staining of ceiling tiles Rotary and scroll compressors Factory charged with R407C Long-life air filter Twin, triple, quadruple configuration possible, on page 72 Accessories: Space panel enables installation into ceiling void of just 258 mm depth High efficiency filter and external airflow For detailed descriptions please view on page 70 and the following 48
49 PLA/PLH 4-WAY-IN-CEILING CASSETTE SYSTEMS COOLING / HEATING INDOOR UNIT PLA-P3 AA PLA-P4 AA PLA-P5 AA PLA-P6 AA INDOOR UNIT WITH ELECTRICAL HEATING PLH-P3 AAH PLH-P4 AAH PLH-P5 AAH PLH-P6 AAH CAPACITY (kw) Cooling Heating* 9.3 (11.4) 10.6 (12.7) 14.9 (17.9) 17.1 (20.1) AIRFLOW (m 3 /h) Low Middle Middle High NOISE db(a) Low High WEIGHT PLA incl. Grille (kg) 24/29 30/35 30/35 32/37 WEIGHT PLA incl. Grille (kg) 26/31 32/37 32/37 34/39 DIMENSIONS (mm) Width Indoor unit Depth Height** DIMENSIONS (mm) Width Grille Depth Height*** , 1, , 1, , 1, , 1, 50 RUNNING CURRENT (A) Cooling Heating* 0.81 (8.75) 1.25 (10.83) 1.43 (12.5) 1.64 (12.5) OUTDOOR UNIT PUH-P3 YGAA PUH-P4 YGAA PUH-P5 YGAA PUH-P6 YGAA POWER CONSUMPTION (kw) Cooling Heating* 3.5 (5.6) 3.9 (6.0) 5.3 (8.3) 6.4 (9.4) AIRFLOW (m 3 /h) NOISE db(a) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C**** (kg) PIPE SIZE Liquid ø (mm) Gas , 3, , 3, , 3, , 3, 50 RUNNING CURRENT (A) Cooling Heating GRILLE-TYPE FOR WIRED REMOTE CONTROL GRILLE-TYPE FOR INFRARED REMOTE CONTROL PLP-6 AAM PLP-6 AALM **** Values given in brackets incl. additional electrical heating **** Required installation height **** Visible height of grille **** Factory charged to 30 m pipe length, optional charging on page 73 The noise levels are measured at a position 1.5 m below the unit in anechoic chamber. 49
50 Mr. Slim Series PCA Cooling / Heating PCH Cooling / Heating Ceiling Suspended Systems Wired remote control with 24h-timer PCH units with additional electrical heating for a warm start and to increase capacity of heat pump Adjustable air outlets for optimum airflow for ceiling heights up to 3.5 m Rotary and scroll compressors Factory charged with R407C Long-life air filter 4 fan-stages for optimum comfort Swing louvres with `Auto Angle airflow Twin, triple, quadruple configuration possible, on page 72 Accessories: High efficiency filter Drain pump Infrared remote control For detailed descriptions please view on page 70 and the following 50
51 Optional PCA/PCH CEILING SUSPENDED SYSTEMS COOLING / HEATING INDOOR UNIT PCA-P2 GA PCA-P2.5 GA PCA-P3 GA PCA-P4 GA PCA-P5 GA PCA-P6 GA INDOOR UNIT WITH ELECTRICAL HEATING PCH-P2 GAH PCH-P2.5 GAH PCH-P3 GAH PCH-P4 GAH PCH-P5 GAH PCH-P6 GAH CAPACITY (kw) Cooling Heating* 6.3 (7.7) 7.3 (9.4) 9.2 (11.3) 10.6 (13.4) 14.9 (17.9) 17.1 (20.1) AIRFLOW (m 3 /h) Low Middle Middle High NOISE db(a) Low High WEIGHT PCA (kg) WEIGHT PCH (kg) DIMENSIONS (mm) Width Depth Height , 1, , 1, , 1, , 1, , 1, , 1, 50 RUNNING CURRENT (A) Cooling Heating* 0.43 (5.83) 0.55 (8.75) 0.55 (8.75) 0.7 (11.25) 1.1 (12.5) 1.1 (12.5) OUTDOOR UNIT PUH-P2 YGAA PUH-P2.5 YGAA PUH-P3 YGAA PUH-P4 YGAA PUH-P5 YGAA PUH-P6 YGAA POWER Cooling CONSUMPTION (kw) Heating* 2.4 (3.8) 2.7 (4.8) 3.5 (5.6) 3.8 (6.55) 5.1 (8.1) 6.3 (9.3) AIRFLOW (m 3 /h) NOISE db(a) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C** (kg) PIPE SIZE Liquid ø (mm) Gas , 3, , 3, , 3, , 3, , 3, , 3, 50 RUNNING CURRENT (A) Cooling Heating ** Values given in brackets incl. additional electrical heating ** Factory charged to 20 m pipe length, PUH-P3/P4/P5/P6 YGAA factory charged to 30 m pipe length, please also view page 73 The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber. 51
52 Mr. Slim Series PCA Cooling / Heating Ceiling Suspended Systems For Applications In Kitchens The established ceiling suspended system consisting of stainless steel for applications in kitchens The special construction enables easy cleaning of the casing and of all airflow parts Oil particles can be filtered 1.5 times more efficient compared to conventional types due to high performance filter (optional) On the rear panel round knockout opening (Ø 200 mm) allows more comfort by supplying fresh air Rotary and scroll compressors Factory charged with R407C Wired remote control with 24h-timer Twin configuration possible, on page 72 Accessories: Oil mist filter (12 pcs.) PAC-SG 38 KF-E For detailed descriptions please view on page 70 and the following 52
53 PCA CEILING SUSPENDED SYSTEMS COOLING / HEATING INDOOR UNIT PCA-P3 HA PCA-P5 HA CAPACITY (kw) Cooling Heating AIRFLOW (m 3 /h) Low High NOISE db(a) Low High WEIGHT (kg) DIMENSIONS (mm) Width Depth Height , 1, , 1, 50 RUNNING CURRENT (A) OUTDOOR UNIT PUH-P3 YGAA PUH-P5 YGAA POWER Cooling CONSUMPTION (kw) Heating AIRFLOW (m 3 /h) NOISE db(a) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C* (kg) PIPE SIZE Liquid ø (mm) Gas , 3, , 3, 50 RUNNING CURRENT (A) Cooling Heating * Factory charged to 30 m pipe length, optional charging on page 73 The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber. 53
54 Mr. Slim Series PKA Cooling / Heating PKH Cooling / Heating Wall Mounted Systems Infrared remote control with 24h-timer PKH units with additional electrical heating for a warm start and to increase capacity of heat pump Slim compact units for wall mounting Simple installation with easy access drain and refrigerant piping connections Rotary and scroll compressors Factory charged with R407C Easily removable long-life air filter PKA/H-P1.6/2 GAL/H with 4 fan-stages Swing louvres with `Auto Angle airflow Twin, triple, quadruple configuration possible, on page 72 Accessories: Drain pump Wired remote control For detailed descriptions please view on page 70 and the following 54
55 Optional PKA/PKH WALL MOUNTED SYSTEMS COOLING / HEATING INDOOR UNIT PKA-P1.6 GAL PKA-P2 GAL PKA-P2.5 FAL PKA-P3 FAL PKA-P4 FAL INDOOR UNIT WITH ELECTRICAL HEATING PKH-P1.6 GALH PKH-P2 GALH PKH-P2.5 FALH PKH-P3 FALH PKH-P4 FALH CAPACITY (kw) Cooling Heating* 5.0 (5.8) 6.3 (7.1) 7.4 (9.5) 9.5 (11.6) 10.9 (13.3) AIRFLOW (m 3 /h) Low Middle Middle High NOISE db(a) Low High WEIGHT PKA (kg) WEIGHT PKH (kg) DIMENSIONS (mm) Width Depth Height , 1, , 1, , 1, , 1, , 1, 50 RUNNING CURRENT (A) Cooling Heating* 0.33 (3.3) 0.33 (3.3) 0.43 (8.75) 0.43 (8.75) 0.52 (10.0) OUTDOOR UNIT PUH-P1.6 YGAA PUH-P2 YGAA PUH-P2.5 YGAA PUH-P3 YGAA PUH-P4 YGAA POWER Cooling CONSUMPTION (kw) Heating* 1.9 (2.7) 2.4 (3.2) 2.6 (4.7) 3.6 (5.7) 3.8 (6.2) AIRFLOW (m 3 /h) NOISE db(a) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C** (kg) PIPE SIZE Liquid ø (mm) Gas , 3, , 3, , 3, , 3, , 3, 50 RUNNING CURRENT (A) Cooling Heating ** Values given in brackets incl. additional electrical heating ** Factory charged to 20 m pipe length, PUH-P3/4 YGAA factory charged to 30 m pipe length, please also view page 73 The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber. 55
56 Mr. Slim Series PSA Cooling / Heating PSH Cooling / Heating Floorstanding units Function panel case integrated and 24h-timer PSH units with additional electrical heating for a warm start and to increase capacity of heat pump Compact design and high capacity Simple installation with easy access drain and refrigerant piping connections Rotary and scroll compressors Factory charged with R407C Standard long-life filter Twin and triple configuration possible, on page 72 Accessories: Optional parts on page 70 and the following 56
57 PSA/PSH FLOORSTANDING UNITS COOLING / HEATING INDOOR UNIT PSA-P3 GA PSA-P4 GA PSA-P5 GA PSA-P6 GA INDOOR UNIT WITH ELECTRICAL HEATING PSH-P3 GAH PSH-P4 GAH PSH-P5 GAH PSH-P6 GAH CAPACITY (kw) Cooling Heating* 9.3 (11.4) 10.9 (13.6) 14.6 (17.6) 17.1 (20.1) AIRFLOW (m 3 /h) Low High NOISE db(a) Low High WEIGHT PSA (kg) WEIGHT PSH (kg) DIMENSIONS (mm) Width Depth Height , 1, , 1, , 1, , 1, 50 RUNNING CURRENT (A) Cooling Heating* 0.68 (8.75) 1.1 (11.25) 1.26 (12.5) 1.62 (12.5) OUTDOOR UNIT PUH-P3 YGAA PUH-P4 YGAA PUH-P5 YGAA PUH-P6 YGAA POWER Cooling CONSUMPTION (kw) Heating* 3.5 (5.6) 3.9 (6.6) 5.4 (8.4) 6.1 (9.1) AIRFLOW (m 3 /h) NOISE db(a) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C** (kg) PIPE SIZE Liquid ø (mm) Gas , 3, , 3, , 3, , 3, 50 RUNNING CURRENT (A) Cooling Heating ** Values given in brackets incl. additional electrical heating ** Factory charged to 30 m pipe length, optional charging on page 73 The noise levels are measured at a position 1 m in front of and 1 m above. 57
58 Mr. Slim Series PEAD Cooling / Heating PEHD Cooling / Heating Above-Ceiling Concealed Ducted Systems Wired remote control with 24h-timer PEHD units with additional electrical heating for a warm start and to increase capacity of heat pump Simple installation with easy access drain and refrigerant piping connections PEAD/PEHD-P1.6/2/2.5 EA/H airflow variable - draw in from the back or underside Rotary and scroll compressors Factory charged with R407C Standard long-life filter Twin, triple, quadruple configuration possible, on page 72 Accessories: Drain pump Fan motor (external static pressure 130 Pa) For detailed descriptions please view on page 70 and the following 58
59 PEAD/PEHD ABOVE-CEILING CONCEALED DUCTED SYSTEMS COOLING / HEATING INDOOR UNIT PEAD-P1.6EA PEAD-P2EA PEAD-P2.5EA PEAD-P3EA PEAD-P4EA PEAD-P5EA PEAD-P6EA INDOOR UNIT W. ELECTRICALHEATING PEHD-P1.6EAH PEHD-P2EAH PEHD-P2.5EAH PEHD-P3EAH PEHD-P4EAH PEHD-P5EAH PEHD-P6EAH CAPACITY (kw) Cooling Heating* 4.9 (5.9) 6.2 (7.2) 7.2 (8.7) 9.1 (11.2) 10.4 (12.9) 13.9 (16.9) 16.7 (19.7) AIRFLOW (m 3 /h) Low High EXTERNAL STATIC PRESSURE (Pa) 30(70) 30(70) 30(70) 70(130**) 70(130**) 70(130**) 70(130**) NOISE db(a) Low 34(36) 36(38) 37(39) 37(40) 41(42) 44(46) 46(47) High 38(43) 40(44) 41(46) 41(45) 46(48) 50(52) 51(53) WEIGHT PEAD (kg) WEIGHT PEHD (kg) DIMENSIONS (mm) Width Depth Height , 1, , 1, , 1, , 1, , 1, , 1, , 1, 50 RUNNING CURRENT (A) Cooling Heating* 0.55 (4.71) 0.63 (4.8) 0.7 (7.0) 1.7 (10.4) 2.6 (12.6) 2.7 (15.2) 2.8 (15.2) OUTDOOR UNIT PUH-P1.6YGAA PUH-P2YGAA PUH-P2.5YGAA PUH-P3YGAA PUH-P4YGAA PUH-P5YGAA PUH-P6YGAA POWER Cooling CONSUMPTION (kw) Heating* 1.8 (2.8) 2.2 (3.2) 2.5 (4.0) 3.2 (5.3) 4.0 (6.5) 4.8 (7.8) 6.0 (9.0) AIRFLOW (m 3 /h) NOISE db(a) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C*** (kg) PIPE SIZE Liquid ø (mm) Gas , 3, , 3, , 3, , 3, , 3, , 3, , 3, 50 RUNNING CURRENT (A) Cooling Heating *** Values given in brackets incl. additional electrical heating *** Fan motor optional on page 70 *** Factory charged to 20 m pipe length, PUH-P3/P4/P5/P6 YGAA factory charged to 30 m pipe length, please also view page 73 The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber. 59
60 Mr. Slim Series PEH Cooling / Heating Concealed Ducted Systems Wired remote control with 24h-timer Pressure to 150 Pa PUH-P8/10 MYA for simultaneous operation of Mr. Slim indoor units Factory charged with R407C Twin, triple, quadruple configuration possible, on page 72 Accessories: Optional parts on page 70 and the following 60
61 PEH CONCEALED DUCTED SYSTEMS COOLING/HEATING INDOOR UNIT PEH-P8 MYA PEH-P10 MYA CAPACITY (kw) Cooling Heating AIRFLOW (m 3 /h) EXTERNAL STATIC PRESSURE (Pa) 50/150 50/150 NOISE db(a) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height , 3, , 3, 50 RUNNING CURRENT (A) Cooling Heating OUTDOOR UNIT PUH-P8 MYA PUH-P10 MYA POWER Cooling CONSUMPTION (kw) Heating AIRFLOW (m 3 /h) NOISE db(a) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C* (kg) PIPE SIZE Liquid ø (mm) Gas , 3, , 3, 50 RUNNING CURRENT (A) Cooling Heating * Factory charged, please view page 73 The noise levels are measured at a position 1.5 m below the unit in anechoic chamber. Rating conditions: COOLING Indoor: 15 C - 24 C WB Outdoor: -15 C - 46 C DB HEATING Indoor: 15 C - 27 C WB Outdoor: -12 C - 18 C DB 61
62 Mr. Slim R410A-Series Power Inverter Split and Multi-Split Systems The established Mr. Slim Series with inverter technology - efficient, economical and very quiet. 62
63 Advantages of Mr. Slim R410A-Series Power Inverter New inverter-technology and refrigerant R410A enable high energy-efficiency The wide range of performance allows an optimum of convenience - for a quick cooling and heating All outdoor units with LOW NOISE - mode, only 44 db(a) at PUHZ-RP3VHA The indoor units RP can be connected with Mr. Slim R407C outdoor units Multi Split simultaneous operation Standard long-life filters Auto change over between cooling and heating mode A-Control makes servicing easier. Automatic switching between heating and cooling is available on heat pump units. Error codes are shown at remote controls display of indoor units Lossnay heat exchange ventilators connectable Factory charged with refrigerant R410A Wired or infrared remote controller optional Remote monitoring Maintenance Tool for control and service All models can be interfaced to Building Management Systems by Lon Works Interface Ceiling cassette models with condensate pump Winter kit as standard, cooling up to -15 C. If the unit is placed in wind direction use the optional part, view page 70 and the following Rating conditions Mr. Slim Series: COOLING Indoor: 19 C - 35 C DB 15 C C WB Outdoor: -15 C - 46 C DB HEATING Indoor: 17 C - 28 C DB Outdoor: -11 C - 24 C DB -12 C - 18 C WB NEW! POWER INVERTER- HEAT PUMP UNITS PLA 4-WAY-IN-CEILING CASSETTE SYSTEMS PKA WALL-MOUNTED SYSTEMS PEAD CEILING CONCEALED SYSTEMS
64 Mr. Slim Power Inverter PLA Cooling / Heating 4-Way-In-Ceiling Cassette Systems NEW! Wired or infrared remote control with 24h-timer provided Space-saving, quadratic design Installation height only 258 mm (PLA-RP3 AA) Quiet operation noise - just 28 db(a) (PLA-RP3 AA) Drain pump for 850 mm height difference Prepared duct connections: round 150 mm, rectangular 350 x 100 mm 4 fan-stages for best comfort Precisely directed airflow to prevent dirt built-up and staining of ceiling tiles Adjustable air outlets for optimum airflow for ceiling heights up to 4.2 m Standard long-life filter - cleaning necessary every 2,500 operating hours Simple installation with easy access drain and refrigerant piping connections Factory charged with R410A Rotary and scroll compressors Multi Split simultaneous operation, view page 72 Accessories: Space panel for installation of PLA-RP4/5/6AA into ceiling void of just 258 mm depth High efficiency filter and external airflow For detailed descriptions please view on page 70 and the following 64
65 POWER INVERTER PLA 4-WAY-IN-CEILING CASSETTE SYSTEMS COOLING / HEATING INDOOR UNIT PLA-RP3 AA PLA-RP4 AA PLA-RP5 AA PLA-RP6 AA CAPACITY COOLING (Min. - Nominal - Max.) kw CAPACITY HEATING (Min. - Nominal - Max.) kw COP Cooling/Heating 3.60/ / / /3.26 AIRFLOW (m 3 /h) Low Middle Middle High NOISE db(a) Low High WEIGHT incl. Grille (kg) 24/29 30/35 30/35 32/37 DIMENSIONS (mm) Width Indoor unit Depth Height** DIMENSIONS (mm) Width Grille Depth Height*** , 1, , 1, , 1, , 1, 50 RUNNING CURRENT (A) Cooling Heating OUTDOOR UNIT PUHZ-RP3VHA PUHZ-RP4VHA PUHZ-RP5VHA PUHZ-RP6VHA POWER Cooling CONSUMPTION (kw) Heating AIRFLOW (m 3 /h) NOISE db(a) 44*/47 46*/49 47*/50 48*/50 WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R410A**** (kg) PIPE SIZE Liquid ø (mm) Gas , 1, , 1, , 1, , 1, 50 RUNNING CURRENT (A) Cooling Heating CIRCUIT BREAKER (A) GRILLE-TYPE FOR WIRED REMOTE CONTROL GRILLE-TYPE FOR INFRARED REMOTE CONTROL PLP-6AAM PLP-6AALM **** LOW NOISE mode **** Required installation height **** Visible height of grille **** Factory charged to 30 m pipe length, optional charging on page 73 The noise levels are measured at a position 1.5 m below the unit in anechoic chamber. Indoor units "RP" can be connected with Mr. Slim R407C outdoor units. 65
66 Mr. Slim Power Inverter PKA Cooling / Heating Wall Mounted Systems NEW! Infrared remote control with 24h-timer Slim compact units for wall mounting Flexible louvre for evenly spread of air Simple installation with easy access drain and refrigerant piping connections Easily removable long-life air filter Factory charged with R407C Rotary and scroll compressors Multi Split simultaneous operation possible, page 72 Accessories: Drain pump Wired remote control For detailed descriptions please view on page 70 and the following 66
67 Optional POWER INVERTER PKA WALL MOUNTED SYSTEMS COOLING / HEATING INDOOR UNIT PKA-RP3FAL PKA-RP4FAL CAPACITY COOLING (Min. - Nominal - Max.) kw CAPACITY HEATING (Min. - Nominal - Max.) kw COP Cooling/Heating 3.59 / / 3.45 AIRFLOW (m 3 /h) Low High NOISE db(a) Low High WEIGHT (kg) DIMENSIONS (mm) Width Depth Height , 1, , 1, 50 RUNNING CURRENT (A) Cooling Heating OUTDOOR UNIT PUHZ-RP3VHA PUHZ-RP4VHA POWER Cooling CONSUMPTION (kw) Heating AIRFLOW (m 3 /h) NOISE db(a) 44*/47 46*/49 WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R410A** (kg) PIPE SIZE Liquid ø (mm) Gas , 1, , 1, 50 RUNNING CURRENT (A) Cooling Heating CIRCUIT BREAKER (A) ** LOW NOISE mode ** Factory charged to 30 m pipe length, please also view page 73 The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber. Indoor units RP can be connected with Mr. Slim R407C outdoor units. 67
68 Mr. Slim Power Inverter PEAD Cooling / Heating Above-Ceiling Concealed Ducted Systems NEW! Wired remote control with 24h-timer Standard long-life filter Installation height only 325 mm Simple installation with easy access drain and refrigerant piping connections Factory charged with R410A Rotary and scroll compressors Multi Split simultaneous operation possible, page 72 Accessories: Drain pump Fan motor (external static pressure 130 Pa) For detailed descriptions please view on page 70 and the following 68
69 POWER INVERTER PEAD ABOVE-CEILING CONCEALED DUCTED SYSTEMS COOLING / HEATING INDOOR UNIT PEAD-RP3EA PEAD-RP4EA PEAD-RP5EA PEAD-RP6EA CAPACITY COOLING (Min. - Nominal - Max.) kw CAPACITY HEATING (Min. - Nominal - Max.) kw COP Cooling/Heating 3.30/ / / /3.36 AIRFLOW (m 3 /h) Low High EXTERNAL STATIC PRESSURE (Pa) 70(130**) 70(130**) 70(130**) 70(130**) NOISE db(a) Low 37(40) 41(42) 44(46) 46(47) High 41(45) 46(48) 50(52) 51(53) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height , 1, , 1, , 1, , 1, 50 RUNNING CURRENT (A) Cooling Heating OUTDOOR UNIT PUHZ-RP3VHA PUHZ-RP4VHA PUHZ-RP5VHA PUHZ-RP6VHA POWER Cooling CONSUMPTION (kw) Heating AIRFLOW (m 3 /h) NOISE db(a) 44*/47 46*/49 47*/50 48*/50 WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R410A*** (kg) PIPE SIZE Liquid ø (mm) Gas , 1, , 1, , 1, , 1, 50 RUNNING CURRENT (A) Cooling Heating CIRCUIT BREAKER (A) *** LOW NOISE mode *** Fan motor optional 130 Pa *** Factory charged to 30 m pipe length, please also view page 73 The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber. Indoor units "RP" can be connected with Mr. Slim R407C outdoor units. 69
70 Mr. Slim R407C/R410A-Series Accessories Accessories Indoor / Outdoor units PART.NO. DESCRIPTION PLA/PLH PAC-SEO6 WP-E PAC-SEO1 AS-E PAC-SE21 TM-E PAC-SE13 KF-E PAC-SE60 AS-E PAC-SG03 TM-E PAC-SG01 KF-E 4-WAY-IN-CEILING CASSETTE SYSTEMS Wide panel for PLA-P 1.6/2/2.5 KA, PLH-P 1.6/2/2.5 KAH Space panel for PLA-P 1.6/2/2.5 KA, PLH-P 1.6/2/2.5 KAH Multi-function casement for PLA-P 1.6/2/2.5 KA, PLH-P 1.6/2/2.5 KAH High efficiency filter for PLA-P 1.6/2/2.5 KA, PLH-P 1.6/2/2.5 KAH (PAC-SE21 TM-E needed) Space panel for PLA-P 4/5/6 AA, PLH-P 4/5/6 AAH Multi-function casement for PLA-P 3/4/5/6 AA, PLH-P 3/4/5/6 AAH High efficiency filter for PLA-P 3/4/5/6 AA, PLH-P 3/4/5/6 AAH (PAC-SG03 TM-E needed) PCA/PCH PAC-SE85 DMA-E PAC-SE86 DMA-E PAC-SE80 KF-E PAC-SE81 KF-E PAC-SE82 KF-E PAC-SL99A-E CEILING SUSPENDED SYSTEMS Drain pump for PCA-P 2/2.5/3 GA, PCH-P2/2.5/3 GAH Drain pump for PCA-P 4/5/6 GA, PCH-P4/5/6 GAH High efficiency filter for PCA-P2 GA, PCH-P2 GAH High efficiency filter for PCA-P2.5/3/4 GA, PCH-P2.5/3/4 GAH High efficiency filter for PCA-P5/6 GA, PCH-P5/6 GAH Infrared remote control for PCA-P/PCH-P PCA PAC-SG38KF-E CEILING SUSPENDED SYSTEMS FOR KITCHEN APPLICATIONS Special high efficiency oil filter, 12 pieces PKA/PKH PAC-SE88 DM-E PAR-20MAAT-E WALL-MOUNTED SYSTEMS Drain pump PKA-P/PKH-P Wired remote control for PKH-P/PKA-P PEAD/PEHD PAC-KE03 DM-F PAC-SK005 MT-F PAC-SK004 MT-F PAC-SK003 MT-F CEILING CONCEALED SYSTEMS Drain pump for PEAD-P/PEHD-P Fan motor 130 Pa pressure for PEAD-P3 EA/PEHD-P3 EAH Fan motor 130 Pa pressure for PEAD-P4 EA/PEHD-P4 EAH Fan motor 130 Pa pressure for PEAD-P5/6 EA/PEHD-P5/6 EAH PU/PUH OUTDOOR UNITS PAC-SF37 DS-E Drain socket for Mr. Slim outdoor units P1.6 P6 PAC-SF08 SG-E Air outlet guide for Mr. Slim outdoor units P1.6 P6 (for P4/5/6 2x PAC-SF08 SG-E) PAC-SF16 DP-E Drain pan PU(H)-P 1.6/4 PAC-SF17 DP-E Drain pan PU(H)-P 5/6 PAC-SF09 AG Airflow panel for cooling to -15 C for P1.6 P6 (for P4/5/6 2x PAC-SF09 AG) PUHZ PAC-SG61DS-E PAC-SG59SG-E PAC-SG64DP-E OUTDOOR UNITS Drain socket for Mr. Slim Power Inverter outdoor units RP3-RP6 Air outlet guide for outdoor units RP3-RP6. RP4/5/6 require two PAC-SG59SG-E Drain pan for PUHZ-RP3/4/5/6 VHA 70
71 Control Accessories Mr. Slim R407C/R410A-Series Accessories PART.NO. PAC-SE41 TS-E PAC-SF48 MA-E PAC-SF40 RM-E PAC-SE55 RA-E CMS-MNF-B LMAP02-E PAC-YT32PTA PAC-SF50MA PAC-SC50KUA PAC-SK52ST DESCRIPTION External Temperature Sensor A/M Net-Converter Operation remote controller board Remote on/off Maintenance Tool, to use with PAC-SF48 MA-E and PAC-SC34 KUA LonWorks -Interface, to use with PAC-SF48 MA-E and PAC-SC50 KUA LCD weekly set back program timer operation only with wired remote control models A/M Net-Converter for Mr. Slim Inverter PUHZ R410 A Power Supply Service-Display for outdoor units P1-P6 and RP3/4/5/6 Further information: Planning handbook Mr. Slim Series 71
72 Accessories for Multi Split Systems*/Distributors: Twin, triple, quadruple configuration of Mr. Slim indoor units with single outdoor units possible. Ideally suited to open plan areas in small- to medium-sized offices or shops. Mr. Slim R407C: Combinations: INDOOR UNITS PLA-P/PLH-P1.6/2/2.5/3/4/5 PSA-P/PSH-P3/4/5 PCA-P/PCH-P2/2.5/3/4/5 PEAD-P/PEHD-P1.6/2/2.5/3/4/5 PKA-P/PKH-P1.6/2/2.5/3/4 PMH-P1.6/2 OUTDOOR UNITS COMIBINATION Twin 50:50 Twin 50:50 Triple 33:33:33 Triple 25:25:50 Triple 20:40:40 Quadruple 25:25:25:25 PU(H)-P3 YGAA PU(H)-P4 YGAA PU(H)-P5 YGAA PU(H)-P6 YGAA PUH-P8 MYA PUH-P10 MYA DISTRIBUTOR SDD-50 DA-E SDD-50WSA-E SDT-111 SA-E SDT-112 SA-E SDT-122 SA-E SDT-1111 SA-E Mr. Slim R410A: Combinations: INDOOR UNITS** PLA-RP1.6/2/2.5/3 PKA-RP1.6/2/2.5/3 PEAD-RP1.6/2/2.5/3 OUTDOOR UNITS COMBINATION Twin 50:50 Triple 33:33:33 PUHZ-RP3VHA ** PUHZ-RP4VHA 2 + 2** PUHZ-RP5VHA ** PUHZ-RP6VHA ** DISTRIBUTOR SDD-50SR-E SDT-111R-E ** Attention: Only indoor units of same type can be installed. In Multi-Split-Mode all indoor units have to be installed in the same room because of temperature sense in the master unit. ** RP1.6/2/2.5 available from August
73 Mr. Slim-Series Technical Data Refrigerants R407C/R410A Charge R407C Charge concerning single operation, optional charges for simultaneous operation as in the planning guide described. Outdoor units P1-2.5: Factory charged to 20 m pipe length Outdoor units P3-P6: Factory charged to 30 m pipe length Outdoor units P8 and P10: Factory charged 6 kg and 6.5 kg R407C. Please view in the table above pipe length and charging data Correction Factor R407C EFFICIENCY CLASS OUTDOOR UNITS CORRECTION FACTOR CAPACITY OF COOLING/HEATING CHARGING (ONE WAY) IN kg 10 m 20 m 30 m 40 m 50 m PUH-P1 VGAA PU(H)-P1.6 YGAA PU(H)-P2 YGAA PU(H)-P2.5 YGAA PU(H)-P3 YGAA PU(H)-P4 YGAA PU(H)-P5 YGAA PU(H)-P6 YGAA PUH-P8 MYA PUH-P10 MYA PIPE LENGTH (ONE WAY)/M P1 1.00/ / / / / /0.989 / / / / P / / / / / / / /0.983 / / P2 1.00/ / / / / / / /0.983 / / P / / / / / / / / / /0.978 P3 1.00/ / / / / / / / / /0.978 P4 1.00/ / / / / / / / / /0.978 P5 1.00/ / / / / / / / / /0.978 P6 1.00/ / / / / / / / / /0.978 P8 1.00/ / / / / / / / / /0.995 P / / / / / / / / / /0.995 Charge R410A Outdoor units PUHZ-P3/4/5/6VHA factory charged to 30 m pipe length (one-way), optional charges as in the table. OUTDOOR UNITS CHARGING (ONE WAY) IN kg 10 m 20 m 30 m 40 m 50 m 60 m 75 m PUHZ-RP3VHA PUHZ-RP4VHA PUHZ-RP5VHA PUHZ-RP6VHA Correction Factor R410A EFFICIENCY CLASS CORRECTION FACTOR CAPACITY OF COOLING/HEATING PIPE LENGTH (ONE WAY)/M RP3 1.00/ / / / / / /0.973 / / / RP4 1.00/ / / / / / / / / /0.958 RP5 1.00/ / / / / / / / /0.958 RP6 1.00/ / / / / / / / / /
74 City Multi-Series Y and R2 For large applications such as office blocks, hotels and large retail stores, City Multi variable refrigerant flow (VRF) multi-split systems offer significant advantages over centralised plant systems. A certain times of the year, many buildings can require cooling in some areas and heating in others even in adjacent rooms. The outstanding City Multi R2 and WR2 systems meet this requirement by distributing surplus heat from cooling operations to rooms where it is needed. This can result in energy savings of up to 20% over conventional systems. The water-cooled WR-system is adaptable specially to high-rise buildings. 74
75 Advantages of the City Multi-Series City Multi Super Y-Series manages up to 32 indoor units in a single refrigerant circle Simultaneous cooling and heating with incomparable 2-pipe-system By distributing surplus heat from cooling operations to rooms where it is needed, the result can be 15% - 20% energy savings over conventional systems Automatic switch of operating mode (heating/cooling), the room temperature stays constant Many indoor units, capacity-steps and installation possibilities to select Inverter-driven outdoor compressor units with very low start currents Remote control of individual indoor units, to centralised systems, right up to full interface with industry standard Building Management Systems CITY MULTI Y-Series City Multi Y-Series utilise 2-pipe technology for cooling and heating mode. By manual switch the most comfortable air conditions can be choosen. The system is very versatile, it is possible to install up to 32 different indoor units to a single refrigerant circle. The capacity of all installed indoor units can be 50% up to 130%. CITY MULTI R2-Series The City Multi range has been re-engineered to use R407C ozone-friendly refrigerant without performance loss. Modern buildings with a reduced exchange of air, technical equipment like PCs, printer etc. which warm up the air require efficient air conditioning with simultaneous cooling and heating. The "Fuzzy-logic makes individual air conditioning with max. 24 indoor units possible. Inverter-driven outdoor compressor units with very low start currents save energy. Distributing surplus heat from cooling operations to rooms where it is needed is another way to save energy. Control options to suit every kind of application City Multi systems offer an extremely wide choice of control solutions, from remote control of individual indoor units, to centralised systems and computer-aided systems which allow to control up to 2,000 units. Right up to full interface with industry standard Building Management Systems. Operating range of City Multi Cooling: indoor C (WB)/outdoor C (DB) (water temperature for WR2: 10 C 45 C) Heating (Y-Series): indoor C (DB)/ outdoor C (WB) Heating (R2-Series): indoor C (DB)/ outdoor C (WB) (water temperature for WR2: 10 C 45 C) Features of City Multi City Multi Y-series - Outdoors units City Multi R2 series - Outdoors units and BC-controllers PMFY/PLFY - Ceiling cassettes PCFY/PKFY - Suspended indoor units PEFY - Concealed ducted indoor units PFFY - Floor standing indoor units City Multi - Control accessoires City Multi - Accessoires
76 City Multi Systems: Economic, efficient and high-quality CITY MULTI Y-SERIES Switching between Heating and Cooling Flexible and Powerful Response from Compact Dimensions Flexibility is the motto with the City Multi Y-Series. A wide line-up of indoor units in combination with a flexible piping system can conform to any layout. From 8 to 32 indoor units, depending on capacity, can be connected to Y-Standard, BIG Y and SUPER Y outdoor units. All indoor units connected to only one refrigerant circuit. This enables easy air conditioning of areas requiring individual control. In common with the R2, the City Multi Y-Series can be easily operated through a central controller. Header Branch Y-Series Outdoor unit Indoor unit Indoor unit 76
77 CITY MULTI R2-SERIES Simultaneous Cooling and Heating excellent air conditioning under the aspect of economy. The R2-System means that simultaneous cooling and heating is possible. With the BC Controller connecting from 4 to 24 indoor units to one outdoor unit using only two pipes and energy-saving heat recovery operation, economy and efficiency are guaranteed. Smooth auto-switching (heating/cooling) based on set temperature realises easier operation and more comfortable environment in auto-mode. The WR2-System uses the same technical bases like the well-known R2-System. But the WR2-Series is the world s only simultaneous heating/cooling two-pipe system with water-cooled outdoor units. WR2-System is specially for high-rise buildings. R2-Series Outdoor unit WR2-Series Outdoor unit Water piping Conference room (cooling) BC Controller Connection Office (cooling) Two-Pipe system Conference room (heating) OA room (cooling) Office (heating) World-wide the only system for simultaneous cooling and heating with 2 pipes. 77
78 Mitsubishi Electric FEATURES of CITY MULTI Flexible and Adaptable The variety provided by 19 outdoor models and 65 indoor models (9 different types) increase design flexibility. The Y-Series: Cooling or heating mode, a maximum of 32 indoor units connectable with one refrigerant circuit. The R2-Series: Simultaneous heating/cooling with up to 24 indoor units and heat recovery by BC-controller. WR2-Series: World s only simultaneous heating/cooling two-pipe system with water-cooled outdoor units. SERIES Outdoor Cooling Heating No. of Total Capacity of unit capacity capacity Connect capacity connectable (kw) (kw) indoor units indoor units indoor models* Y-SERIES PUMY-P125 YMA , % PUY-P200 YEM-A PUY-P250 YEM-A PUY-P315 YEM-A % PUHY-P200 YEM-A PUHY-P250 YEM-A PUHY-P315 YEM-A , R407C BIG Y- SERIES SUPER Y- SERIES PUHY-P400 YMF-C PUHY-P500 YMF-C PUHY-P400 YMF-C + PUHN-P200 YMF-C PUHY-P400 YMF-C + PUHN-P250 YMF-C PUHY-P500 YMF-C + PUHN-P200 YMF-C PUHY-P500 YMF-C + PUHN-P250 YMF-C % % R2-SERIES BIG R2- SERIES WR2- SERIES PURY-P200 YEM-A PURY-P250 YEM-A PURY-P400 YMF-C PURY-P500 YMF-C PQRY-P200 YMF-C PQRY-P250 YMF-C % % % * Indoor units available: Type 20 (2.2 kw) up to type 250 (28.0 kw) 78
79 Indoor units - Overview All City Multi indoor units are compatible to Y-Series, R2- and WR2-Series. Capacity Capacity code P 20 P 25 P 32 P 40 P 50 P 63 P 71 P 80 P 100 P 125 P 140 P 200 P 250 Cooling capacity (kw) Type Heating capacity (kw) Ceiling Cassette Type (1-way airflow) PMFY-VBM-A Ceiling Cassette Type (2-way airflow) PLFY-VLMD-A/-B Ceiling Cassette Type (4-way airflow) PLFY-VKM-A/VAM-A B-model A-model Ceiling Concealed (horizontal airflow) PEFY-VML-A/VMH-A Ceiling Concealed (variable airflow) PEFY-VMM-A L-model* H-model* Ceiling Suspended Type PCFY-VGM-A Wall Mounted Type PKFY-VAM-A Wall Mounted Type PKFY-VGM-A Floor Standing Exposed Type PFFY-VLEM-A Floor Standing Concealed Type PFFY-VLRM-A * L-model: low stat. pressure, H-model: high stat. pressure 79
80 Outdoor units - Technical data City Multi Y-Series, Cooling or Heating City Multi Y-Series: PUMY-P125 YMA OUTDOOR UNIT PUMY-P125 YMA MODEL REFERENCE PUMY-P125 YMA CAPACITY (kw) Cooling 14.0 Heating 16.0 AIRFLOW (m 3 /h) 5400 NOISE* db(a) 54 WEIGHT (kg) 127 DIMENSIONS (mm) Width 1020 Depth 350 Height* 1280 MAX. PIPE LENGTH** (m) 100 MAX. HEIGHT DIFFERENCE (m) 30 CHARGE R407C*** (kg) 8.5 PIPE SIZE ø (mm) liquid 10 gas V, 50Hz, 3 INPUT POWER (kw) Cooling 5.95 Heating 5.58 STARTING CURRENT (A) 8 RUNNING CURRENT (A) 9.1 INDOOR UNITS TO INSTALL (pcs.) 1-8 / City Multi Standard Y: PU(H)Y-P 200/250/315 YEM-A STANDARD Y OUTDOOR UNIT COOLING ONLY COOLING/HEATING MODEL REFERENCE PUY- PUY- PUY- PUHY- PUHY- PUHY- P200YEM-A P250YEM-A P315YEM-A P200YEM-A P250YEM-A P315YEM-A CAPACITY (kw) Cooling Heating AIRFLOW (m 3 /h) NOISE* db(a) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height* MAX. PIPE LENGTH** (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C (kg) PIPE SIZE ø (mm) liquid gas V, 50Hz, V, 50Hz, V, 50Hz, 3 INPUT POWER (kw) Cooling Heating STARTING CURRENT (A) RUNNING CURRENT (A) INDOOR UNITS TO INSTALL (Number/Type) 1-13/ / / / / / *** The noise levels are measured at a position 1 m in front of and 1 m above the unit in anechoic chamber. *** one-way *** Factory charged to 50 m pipe length (one-way) 80
81 City Multi BIG Y and Super Y-Series BIG Y OUTDOOR UNITS MODEL REFERENCE PUHY-P400YMF-C PUHY-P500YMF-C CAPACITY (kw) Cooling Heating AIRFLOW (m 3 /h) NOISE* db(a) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH** (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C (kg) PIPE SIZE ø (mm) liquid gas V, 50Hz, 3 INPUT POWER (kw) Cooling Heating INDOOR UNITS TO INSTALL (pcs.) 1-20/ City Multi Big Y: PUHY-P400/500 YMF-C PUHN UNITS MODEL REFERENCE PUHN-P200YMF-C PUHN-P250YMF-C CAPACITY (kw) Cooling Heating AIRFLOW (m 3 /h) NOISE* db(a) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH** (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C (kg) PIPE SIZE ø (mm) liquid gas V, 50Hz, 3 INPUT POWER (kw) Cooling Depending of Combination Heating City Multi Super Y SUPER Y: COMBINATION OF BIG Y AND PUHN MODEL REFERENCE Cooling capacity (kw) Heating capacity (kw) Noise level Indoor units to install db(a) (pcs.) Super Y PUHY-P400YMF-C + PUHN-P200YMF-C / Super Y PUHY-P400YMF-C + PUHN-P250YMF-C / Super Y PUHY-P500YMF-C + PUHN-P200YMF-C / Super Y PUHY-P500YMF-C + PUHN-P250YMF-C / When adding 20 or more indoor units to one system transmission booster PAC-SF46EPA is needed. For connecting PUHN use SUPER Y Kit CMC-30A. ** The noise levels are measured at a position 1 m in front of and 1 m above the unit in anechoic chamber. ** one-way 81
82 Outdoor units - Technical data City Multi R2-Series City Multi R2: PURY-P 200/250 YEM-A Cooling + Heating simultaneous with heat recovery R2-OUTDOOR UNITS MODEL REFERENCE PURY- P200YEM-A PURY- P250YEM-A CAPACITY (kw) Cooling Heating AIRFLOW (m 3 /h) NOISE* db(a) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH** (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C (kg) PIPE SIZE ø (mm) liquid gas V, 50Hz, V, 50Hz, 3 INPUT POWER (kw) Cooling Heating STARTING CURRENT (A) 8 8 RUNNING CURRENT (A) INDOOR UNITS TO INSTALL (pcs.) 1-15/ / City Multi WR2: PQRY-P200/250 YMF-C Note: 1) Cooling/heating capacity indicates the maximum value at operation under the following conditions: Cooling/outdoor: 35 C DB/24 C WB Watertemperature WR2 30 C Heating/outdoor: 7 C DB/6 C WB Watertemperature WR2 20 C 2) The ambient temperature of heat source units has to be kept below 40 C DB. The ambient relative humidity of heat source units has to be kept below 80% WR2-SERIES WITH WATER COOLED HEAT EXCHANGER (ONLY FOR INDOOR USE) MODEL REFERENCE PQRY-P200YMF-C PQRY-P250YMF-C CAPACITY (kw) Cooling Heating COOLING WATER FLOW RATE (m 3 /h) PRESSURE DROP (k Pa) 8 10 MAX. PIPING LENGTH** (m) REFRIGERANT CIRCUIT MAX. HIGH DIFFERENCE (m) REFRIGERANT CIRCUIT CHARGE R407C (kg) NOISE* db(a) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height V, 50Hz, 3 INPUT POWER (kw) Cooling Heating STARTING CURRENT (A) RUNNING CURRENT (A) PIPE SIZE ø (mm) liquid GAS OPERATING TEMP. RANGE COOLING INDOOR 15ºC 24ºC (WB) / watertemp.10º C 45º C HEATING INDOOR 15ºC 27ºC (DB) / watertemp.10º C 45º C INDOOR UNITS NO./TYPE 1-15/ / BC-Controller required for R2/WR2 ** Noise level measured at a position of 1m in front of the unit. ** one-way 82 BC-CONTROLLER FOR R2/WR2-SERIES MODEL REFERENCE CMB- CMB- CMB- CMB- CMB- CMB- CMB- P104V-F P105V-F P106V-F P108V-F P1010V-F P1013V-F P1016V-F NUMBER OF CONNECTIONS PIPE SIZE EXT., ø (mm) liquid gas BC-Controller at outdoor unit PIPE SIZE EXT. ø (mm) liquid gas Indoor unit at BC-Controller WEIGHT (kg) DIMENSIONS (mm) Width Depth Height , (V, Freq.,Phase) V, 50Hz, 1 INPUT POWER (kw) RUNNING CURRENT (A)
83 BIG R2-OUTDOOR UNITS MODEL REFERENCE PURY-P400YMF-C PURY-P500YMF-C CAPACITY (kw) Cooling 45,0 56,0 Heating ,0 AIRFLOW (m 3 /h) NOISE* db(a) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX PIPE LENGTH** (m) MAX HIGH DIFFERENCE (m) CHARGE R407C (kg) PIPE SIZE ø (mm) liquid gas (V, Freq.,Phase) V, 50Hz, 3 INPUT POWER (Cooling) 16, (Heating) INDOOR UNITS TO INSTALL No./Type 2-24/ ** The noise levels are measured at a position 1 m in front of and 1 m above the unit in anechoic chamber. ** one-way City Multi Big R2: PURY-P400/500 YMF-C MASTER-CONTROLLER FOR BIG R2-SERIES MODEL REFERENCE CMB- CMB- CMB- CMB- P108V-FA P1010V-FA P1013V-FA P1016V-FA NUMBER OF CONNECTIONS PIPE SIZE EXT., ø (mm) liquid gas BC-Controller at outdoor unit PIPE SIZE EXT. ø (mm) liquid gas Indoor unit at BC-Controller PIPE SIZE EXT. ø (mm) liquid gas Master-Controller at Slave-Controller WEIGHT (kg) DIMENSIONS (mm) Width Depth Height , (V, Freq.,Phase) V, 50Hz, 1 INPUT POWER (kw) RUNNING CURRENT (A) Master- Controller SLAVE-CONTROLLER FOR BIG R2-SERIES MODEL REFERENCE CMB- P108V-FB NUMBER OF CONNECTIONS 8 PIPE SIZE EXT., ø (mm) liquid 12 gas 18 Slave Controller at Master Controller 28 PIPE SIZE EXT. ø (mm) liquid 10 gas 16 Indoor unit at Slave Controller WEIGHT (kg) 32 DIMENSIONS (mm) Width 648 Depth 432 Height 284, (V, Freq.,Phase) V, 50Hz, 1 INPUT POWER (kw) RUNNING CURRENT (A) 0.53 Slave- Controller Note: The Slave BC-Controller can only use in combination with the Master Controller 83
84 Indoor Units - Technical Data PMFY 1-WAY IN-CEILING CASSETTES MODEL REFERENCE PMFY-P20VBM-A PMFY-P25VBM-A PMFY-P32VBM-A PMFY-P40VBM-A GRILLE MODEL PMP-40 BM PMP-40 BM PMP-40 BM PMP-40 BM CAPACITY (kw) Cooling Heating AIRFLOW (m3/h) Low Middle Middle High NOISE* (Low/High) db(a) 27/35 32/37 32/37 33/39 WEIGHT / incl. Grille (kg) 14 (17) 14 (17) 14 (17) 14 (17) DIMENSIONS (mm) (Grille) Width 854 (1000) 854 (1000) 854 (1000) 854 (1000) Depth 395 (470) 395 (470) 395 (470) 395 (470) Height** 230 (30) 230 (30) 230 (30) 230 (30) PIPE SIZE ø (mm) liquid gas (V, Freq.,Phase) V, 50 Hz, 1 INPUT POWER (kw) RUNNING CURRENT (A) * The values given in the table for the noise level reflect the measured at a position 1.5 m below the unit in anechoic chamber ** Needed installation height, in brackets: Visible grille height PLFY 2-WAY IN-CEILING CASSETTES MODEL REFERENCE PLFY- PLFY- PLFY- PLFY- PLFY- PLFY- PLFY- PLFY- PLFY- P20VLMD-B P25VLMD-B P32VLMD-B P40VLMD-B P50VLMD-B P63VLMD-B P80VLMD-A P100VLMD-A P125VLMD-A GRILLE MODEL CMP-40 CMP-40 CMP-40 CMP-40 CMP-63 CMP-63 CMP-63 CMP-125 CMP-125 VLW-B VLW-B VLW-B VLW-B VLW-B VLW-B LW-F LW-F LW-F CAPACITY (kw) Cooling Heating AIRFLOW (m3/h) Low Middle Middle High NOISE* (Low/High) db(a) 27 / / / / / / / / / 46 WEIGHT / incl. Grille (kg) 23 (29.5) 23 (29.5) 24 (30.5) 24 (30.5) 27 (34.5) 28 (35.5) 41 (51) 56 (67.5) 56 (67.5) DIMENSIONS (mm) Width 776 (1080) 776 (1080) 776 (1080) 776 (1080) 946 (1250) 946 (1250) 1358 (1650) 1708 (2000) 1708 (2000) (Grille) Depth 634 (710) 634 (710) 634 (710) 634 (710) 634 (710) 634 (710) 606 (670) 606 (670) 606 (670) Height** 338 (20) 338 (20) 338 (20) 338 (20) 338 (20) 338 (20) 338 (8) 338 (8) 338 (8) PIPE SIZE ø (mm) liquid gas (V, Freq.,Phase) V, 50Hz, 1 INPUT POWER (kw) RUNNING CURRENT (A) * The values given in the table for the noise level reflect the measured at a position 1.5 m below the unit in anechoic chamber ** Needed installation height, in brackets: Visible grille height PLFY 4-WAY IN-CEILING CASSETTES PLFY- PLFY- PLFY- PLFY- PLFY- PLFY- PLFY- MODEL REFERENCE P32VKM-A P40VKM-A P50VKM-A P63VKM-A P80VAM-A P100VAM-A P125VAM-A GRILLE MODEL PLP-2.5KC PLP-2.5KC PLP-2.5KC PLP-2.5KC PLP-6AA PLP-6AA PLP-6AA CAPACITY (kw) Cooling Heating AIRFLOW (m3/h) Low Middle Middle High NOISE* (Low/High) db(a) 31 / / / / / / / 43 WEIGHT / incl. Grille (kg) 19 (22.7) 19 (22.7) 19 (22.7) 20 (23.7) 24 (29) 30 (35) 30 (35) DIMENSIONS Width 660 (760) 660 (760) 660 (760) 660 (760) 840 (950) 840 (950) 840 (950) (Grille) Depth 660 (760) 660 (760) 660 (760) 660 (760) 840 (950) 840 (950) 840 (950) Height** 298 (30) 298 (30) 298 (30) 298 (30) 258 (30) 298 (30) 298 (30) PIPE SIZE ø (mm) liquid gas (V, Freq.,Phase) V, 50Hz,1 INPUT POWER (kw) RUNNING CURRENT (A) * The values given in the table for the noise level reflect the measured at a position 1.5 m below the unit in anechoic chamber ** Needed installation height, in brackets: Visible grille height 84
85 PCFY SUSPENDED INDOOR UNITS MODEL REFERENCE PCFY- P40VGM-A PCFY- P63VGM-A PCFY- P100VGM-A PCFY- P125VGM-A CAPACITY (kw) Cooling Heating AIRFLOW (m3/h) Low Middle Middle High NOISE* db(a) 29 / / / / 44 (Low/High) WEIGHT (kg) DIMENSIONS (mm) Width Depth Hight PIPE SIZE ø (mm) liquid gas (V, Freq.,Phase) V, 50Hz, 1 INPUT POWER (kw) RUNNING CURRENT (A) *The values given in the table for the noise reflect the levels measured at a position 1 m in front of and 1 m below the unit in anechoic chamber PKFY WALL MOUNTED INDOOR UNITS MODEL REFERENCE PKFY-P20VAM-A PKFY-P25VAM-A PKFY-P32VGM-A PKFY-P40VGM-A PKFY-P50VGM-A CAPACITY (kw) Cooling Heating AIRFLOW (m3/h) Low Middle Middle High NOISE* db(a) 32 / / / / / 43 (Low/High) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height PIPE SIZE ø (mm) liquid gas (V, Freq.,Phase) V, 50Hz, 1 INPUT POWER (kw) RUNNING CURRENT (A) *The values given in the table for the noise reflect the levels measured at a position 1 m in front of and 1 m below the unit in anechoic chamber 85
86 Indoor Units - Technical Data PEFY CONCEALED DUCTED (REAR OR BOTTOM SUCTION) INDOOR UNITS, VML WITH FILTER AS STANDARD MODEL REFERENCE PEFY- PEFY- PEFY- PEFY- PEFY- PEFY- PEFY- P20VML-A P25VML-A P32VML-A P40VMH-A P50VMH-A P63VMH-A P71 VMH-A CAPACITY (kw) Cooling Heating AIRFLOW (m3/h) Low Middle High EXT. STATIC PRESSURE (Pa) / 100 /150 / 200 NOISE* (Low/High) db(a) 29/36 29/36 30/40 27/34 27/34 32/38 32/39 WEIGHT (kg) DIMENSIONS (mm) Width Depth Hight PIPE SIZE ø (mm) liquid gas (V, Freq.,Phase) V, 50Hz, 1 INPUT POWER (kw) RUNNING CURRENT (A) PEFY CEILING CONCEALED DUCTED (REAR SUCTION) INDOOR UNITS MODEL REFERENCE PEFY- P80VMH-A PEFY- P100VMH-A PEFY- P125VMH-A PEFY- P140VMH-A** PEFY- P200VMH-A** PEFY- P250 VMH-A** CAPACITY (kw) Cooling Heating AIRFLOW (Low/High) (m3/h) 1080/ / / / EXT. STATIC PRESSURE (Pa) 50/100/150/ /130/220/260 NOISE* (Low/High) db(a) 35/41 34/42 34/42 34/42 45*** 52*** WEIGHT (kg) DIMENSIONS (mm) Width Depth Hight PIPE SIZE ø (mm) liquid gas (V, Freq.,Phase) V, 50Hz, V, 50Hz, 3 INPUT POWER (kw) (kw) RUNNING CURRENT (A) ***The values given in the table for the noise reflect the levels measured at a position 1.5 m below the unit in anechoic chamber *** Refering to projects. Please ask for delivery times. *** at 220 PA PEFY CEILING CONCEALED DUCTED (REAR OR BOTTOM SUCTION) INDOOR UNITS, FILTER AS STANDARD MODEL REFERENCE PEFY- PEFY - PEFY - P20VMM-A P25VMM-A P32VMM-A PEFY - P40VMM-A PEFY - P50VMM-A PEFY - PEFY - PEFY - PEFY - PEFY - PEFY - P63VMM-A P71VMM-A P80VMM-A P100VMM-A P125VMM-A P140VMM-A CAPACITY (kw) Cooling Heizleistung Heating AIRFLOW(m3/h) Low Middle High EXT. STATIC PRESSURE (Pa) 30/50/100 30/50/100 30/50/100 30/50/100 30/50/100 30/50/100 30/50/100 30/50/100 50/130 50/130 50/130 NOISE* (Low/High) db(a) 27 / / / / / / / / / / / 45 WEIGHT (kg) DIMENSIONS (mm) Width Depth Hight PIPE SIZE ø (mm) liquid gas (V, Freq.,Phase) V, 50Hz, 1 INPUT POWER (kw) RUNNING CURRENT (A) *The values given in the table for the noise reflect the levels measured at a position 1.5 m below the unit in anechoic chamber 86
87 PFFY FLOOR STANDING (CONCEALED TYPE) INDOOR UNITS MODEL REFERENCE PFFY- PFFY- PFFY- PFFY- PFFY- PFFY- P20VLRM-A P25VLRM-A P32VLRM-A P40VLRM-A P50VLRM-A P63VLRM-A CAPACITY (kw) Cooling Heating AIRFLOW (m3/h) 330/ / / / / /930 (Low/High) NOISE* db(a) 31 / / / / / / 43 (Low/High) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height PIPE SIZE ø (mm) liquid gas (V, Freq., Phase) V, 50Hz, 1 INPUT POWER (kw) RUNNING CURRENT (A) *The values given in the table for the noise reflect the levels measured at a position 1 m in front of and 1 m above the unit in anechoic chamber PFFY FLOOR STANDING (CABINET TYPE) INDOOR UNITS MODEL REFERENCE PFFY- PFFY- PFFY- PFFY- PFFY- PFFY- P20VLEM-A P25VLEM-A P32VLEM-A P40VLEM-A P50VLEM-A P63VLEM-A CAPACITY (kw) Cooling Heizleistung Heating AIRFLOW (m3/h) 330/ / / / / /930 (Low/High) NOISE* db(a) 31 / / / / / / 43 (Low/High) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height PIPE SIZE ø (mm) liquid Anschlüsse, außen ø (mm) gas (V, Freq.,Phase) V, 50Hz, 1 INPUT POWER (kw) RUNNING CURRENT (A) *The values given in the table for the noise reflect the levels measured at a position 1 m in front of and 1 m above the unit in anechoic chamber 87
88 City Multi System Control Standard Remote Control PAR-20MAA PAR-20 MAA to connect at the indoor unit, building of groups of seperate Databus System possible 1 Indoor unit individual, 1 Group with 16 indoor units possible by two-wire signal lines Easy to read, easy to operate display On/Off Timer Temperature selection in 1 C units Auto-diagnosis display A microcomputer constantly monitors operation to keep the units running smoothly. Should problems occure, the temperature setting display changes to an auto-diagnosis display that shows the inspection mode and the unit address alternately. Room thermometer is built into the remote controller. Switching possible to indoor unit room thermometer. PAR-F27 MEA PAR-F27 MEA to connect at the City Multi Databus System, easy to form groups 1 Indoor unit individual / 1 Group with16 indoor units Easy to read, easy to operate display Extensive time function Temperature selection in 1 C units Auto-diagnosis display A microcomputer constantly monitors operation to keep the units running smoothly. Should problems occure, the temperature setting display changes to an auto-diagnosis display that shows the inspection mode and the unit address alternately. Room thermometer is built into the remote controller. Switching possible to indoor unit room thermometer. Limit temperature setting Operating status readout Exposed type PAC-SE51 CRA PAC-YT51 CRA* To simplify operation of the system, the range of controls has been limited to START/STOP, room temperature and fan speed The only wiring required is cross-over wiring based on two-wire signal lines Room temperature sensors are built-in The indoor unit can be replaced with body thermostats Easy-to-read, easy-to-operate icon display Temperature selection Can operate all types of indoor units Standardized remote controllers for all indoor units 1 indoor unit individual/1 group with 16 indoor units PAC-SE51 CRA Grouping addressing by data bus PAC-YT51 CRA Main grouping by two-wire signal lines *Since this system has no operation mode switching, test operation, self-diagnosis or linked setting functions, it should always be used in conjunction with the PAR-F27MEA or other centralized controller. 88
89 City Multi System Control Accessories Infrared-, Group- and System Remote Control Timer PAR-FL31MA Infrared-Remote Control PAR-FL31 MA and PAR-FA31 MA (Signal receiver) PAR-FA31MA It can operate in a group system without requiring address settings When operating, it displays LED lamps. When errors occure, the error can be shown by the LED flash count 1 Indoor unit individual/1 group with 16 indoor units by two-wire signal lines Group Remote Control PAC-SC30 GRA PAC-SC30GRA Easy to read, easy to operate display Temperature selection in 1 C units Auto-diagnosis-display A microcomputer constantly monitors operation to keep the units running smoothly. Should problems occure, the temperature setting display changes to an auto-diagnosis display that shows the inspection mode and the unit address alternately. 8 Indoor units individual / Max. 16 Indoor units in 8 groups Programme Timer PAC-YT32 PTA One-week scheduling by remote controller Set-back function Control for PAR-F27 MEA (1 Indoor unit individual / 1 group with 16 indoor units) PAC-YT32 PTA 89
90 City Multi System Control Accessories Infrared-, Group- and System Remote Control Timer On/Off Remote Controller PAC-YT40 ANRA Up to 50 groups Price competitive solution, up to 50 indoor units PAC-YT40 ANRA System Remote Controller PAC-SF44 SRA PAC-SF44SRA Control range as Standard Controller (Air Outlet Angle/Air Filter) Limited room air temperature selection Auto diagnosis system 50 indoor units individual/max. 50 indoor units with 50 groups Lock-out function for PAR-F27 MEA External Input/Output System Timer PAC-YT34 STA PAC-YT34 STA Directly connected to the M-Net databus 50 groups/max. 50 indoor units Timer-controlled mode Timer-controlled temperature 9 Timer functions Lock-off selection (On/Off/Mode/Temperatue) 90
91 City Multi The New Controller G-50 A The Next Controller Generation G-50A Simple and flexible The central controller G-50 A is equally suitable for small and large systems. Web browser Use a standard web browser on your PC, e.g. Microsoft Internet ExplorerTM, to operate and monitor the air-conditioning unit, which is connected to your local Intranet, in comfort. Integrated software The easy to understand operating software is already integrated in the G-50 A. This represents Mitsubishi Electric s own innovation and is not Windows-based. It is therefore impossible for hackers to spy in your system data. Three password levels You can safeguard against unauthorised access to the air-conditioning system on three operating levels which are individually protected by passwords of your choice. Access to an air-conditioning unit (or group) e.g. for each office/floor but without the possibility to change the system settings Access to group and maintenance functions, e.g. for in-house technicians Access to the entire system, e.g. for the system administrator Remote access You can also operate your air-conditioning system with your PC by remote control via your local intranet or phone connection. The access is protected by a password of your choice. Automatic alarm If an error occurs, the G-50 A sends a message with the most important information to a mobile phone (SMS) or an to an address of your choice. Always up-to-date Upgrades with continuously updated special functions are available for the G-50 A. Examples: Energy consumption data for individual cost statements Special economy programmes Annual schedules HARDWARE FOR G-50A Pos. Type Description 1 G-50A - Standard Standard central controller for 50 air conditioners 2 G-50A - Pro As above G-50 incl. Web function & annual schedule, programmed for clients demand 3 PAC-SC 50 KUA Power supply unit for G-50 4 BTX-1000 Router according to ME specification & installation is required depending to clients demands 5 PC* with software TG 2000 PC according Me specification & installation with OS, Internet Explorer and software TG Watt Hour Meter Amount of WHM is depend of the project SOFTWARE FOR G-50A Web Function Personal Web RC Power consumption Ratio Demand Control I Demand Control II Annual Schedule Data Export Error scanning function Auto Alarming Service BACnet PLC Set free Homepage Remote Control via PC Calculate individual cost*** Limit temperature range, optimize indoor-outdoor unit** Peak Cut*** only connection with PLC + PLC Software Weekly and Yearly Timer** Trend Graph*** Monitoring Error History Auto Alarm function Error Code mailing Maintenance Tool function BACnet Connection PLC connection direct with G-50 via RJ45 TG 2000 Installation TG 2000 software according customer requirement * Computer periphery like Monitor, Keyboard, Mouse, Printer from client ** Operation with G-50 or Pos. 5 *** Additional pos. 5 nessassary, for Power consumption ration additional Pos. 6 nessassary 91
92 City Multi Central Remote Control LonWorks Interface Maintenance Tool Lon Works -Interface L-MAP02-E Easy connection of City Multi Systems through LMAP02-E, the Lon Works -M-Net protocol converter, the total system requirements of engineers and end-users can be met more effectively and simply. 1 Lon Works -Interface manages 50 indoor units. Maintenance Tool - CMS-MNF-B Using Maintenance Tool is the easiest way for controlling, servicing and operating the City Multi system. All system information will be displayed on personal computer* screen based on Windows Software and settings can be changed. In addition, error code numbers are output onto the display. Easy maintenance is assured through the trouble history printer output and call functions. Besides ths connection with modem and data transfer is possible. CMS-MNF-B consists of converter box and software, RS-232 cable (cross) is needed. * Windows 3.1 or Windows 95, Pentium 75 MHz or more, 16 MB RAM, free space 10 MB on HDD. 92
93 City Multi Accessories CONTROLS MODEL REFERENCE DESCRIPTION PAC-SF48MA-E A to M-Net transmission converter PAC-SE40TS-E Temperature sensor PAC-725AD Remote indicator (Pack of 10) PAC-SA88HA-E Remote indicator (Pack of 1) PAC-SF46EPA Transmission booster ACCESSORIES MODEL REFERENCE PLFY-P-VKM/VAM-A PAC-SE06WP-E PAC-SE01AS-E PAC-SE60AS-E DESCRIPTION Wide panel for PLFY-P32/40/50/63 VKM-A Space panel for PLFY-P32/40/50/63 VKM-A Space panel for PLFY-P80/100/125 VAM-A PAC-SE13FK-E PAC-SG01KF PAC-SE21TM-E PAC-SG03TM-E PCFY-P-VGM-A PAC-SE80KF-E PAC-SE81KF-E PAC-SE82KF-E PAC-SE84DM-E PAC-SE85DM-E PAC-SE86DM-E PEFY-P-VML/VMH-A PAC-KE04DM-F PAC-KE32LAF-F PAC-KE86LAF PAC-KE88LAF PAC-KE89LAF PAC-KE85LAF PAC-KE63TB-F PAC-KE80TB-F PAC-KE140TB-F PAC-KE250TB-F PEFY-P-VMM-A PAC-KE03DM-F PAC-KE32EDF-F PAC-KE50EDF-F PAC-KE80EDF-F PAC-KE125EDF-F PAC-KE140EDF-F PU(H)Y-P/PURY-P-YMF-B/C PAC-KBU02MT-F PAC-KBU03MT-F High efficiency filter for PAC-SE21TM-E High efficiency filter for PAC-SG03TM-E Multifunction casement for PLFY-P32/40/50/63 VKM-A Multifunction casement for PLFY-P80/100/125 VAM-A High efficiency filter for PCFY-P40 VGM-A High efficiency filter for PCFY-P63/100 VGM-A High efficiency filter for PCFY-P125 VGM-A Drain pump for PCFY-P40 VGM-A Drain pump for PCFY-P63 VGM-A Drain pump for PCFY-P100/125 VGM-A Drain pump for PEFY-P-VMH-A Replacement filter for PEFY-P20/25/32 VML Optional filter for PEFY-P40/50/63 VMH Optional filter for PEFY-P71/80 VMH Optional filter for PEFY-P100/125/140 VMH Optional filter for PEFY-P200/250 VMH Filter box for PEFY-P40/50/63 VMH Filter box for PEFY-P71/80 Filter box for PEFY-P100/125/140 Filter box for PEFY-P200/250 Drain pump for PEFY-P-VMM-A Round duct flange for PEFY-P20/25/32 VMM-A Round duct flange for PEFY-P40/50 VMM-A Round duct flange for PEFY-P63/71/80 VMM-A Round duct flange for PEFY-P100/125 VMM-A Round duct flange for PEFY-P140 VMM-A High static pressure motor, 30 PA for PU(H)Y-/PURY- P200/250 YMF-C High static pressure motor, (30) 60 PA for PU(H)Y-/PURY- P200/250/315 YEM-A REFRIGERANT PIPES CMY-R160-H Junction pipe kit for BC-Controller CMY-R160-HA Junction pipe kit for BC-Controller 2 x CMY-R160-H CMY-Y102S-F* Joint for capacity 160 or below CMY-Y102L-F* Joint for capacity from 161 up to 330 CMY-Y202-F* Joint for capacity from 331 up to630 CMY-Y302-F* Joint for capacity 631 or above CMY-Y104-F* Header (4 branch) CMY-Y107-F* Header (7 branch) CMY-Y1010-F* Header (10 branch) CMC-30A Super Y Kit *you can use also Standard T-Branch 93
94 Lossnay Ventilation Systems with heat recovery VL-Series/LGH-Series The sophisticated heat recovery technology of the Lossnay Element saves energy even while keeping your room comfortable. The simultaneous intake/exhaust of air together with the Lossnay core recovers temperature and humidity from the room. The system s benefit is to use the released cooling or heating energy for fresh air conditioning. 94
95 Ventilation without wasting energy Ventilation of buildings can waste considerable amounts of heating or cooling energy. The Lossnay system can utilise a high percentage of this energy to cut operating costs between 20% and 50% of the power what would otherwise be required to maintain a constant temperature. Save capital costs too By utilising this lost energy, the capacity of installed heating and cooling systems can also be reduced, with a consequent saving in capital costs of up to 30%. Lossnay units are designed to keep exhaust air and fresh air completely separate and yet still achieve an efficiency in the range of 60% to 70%. The fresh air then enters the room at a similar temperature to be expelled air, to provide comfortable environmental conditions all year round. Lossnay at work - and at home Lossnay total heat exchange ventilators are available in ranges for both commercial installations and residential use. LOSSNAY HEAT EXCHANGE SYSTEM Stale air expelled outside Outside air is drawn in Stale internal air recovery Renewed internal air Operating range Lossnay system VL-Series: t = -10 C bis 40 C, ϕ = 60% max LGH-Series: t = -10 C bis 40 C, ϕ = 80% max 95
96 Lossnay VL-Series Wall Mounted Systems Model VL-100 LOSSNAY-VL-SERIES MODEL REFERENCE VL-100U-E (V, PHASE,Hz) , 1, 50 POWER INPUT (W) Low 23 High 26 AIRFLOW Low 65 (m 3 /h) High 105 NOISE* Low 29.5 db(a) High 39 EFFICIENCY (%) Low 77 High 70 WEIGHT (kg) 6.5 DIMENSIONS (mm) Width 620 Depth 168 Height 265 DUCT SIZE (mm) 2x75ø To install the units of the Lossnay Series VL-100 only 2 x 75 mm diameter bores are necessary. Supply and return air ducts and protective caps against invading rain water are included in delivery. The units operate very quietly, selection between 2 fan speed levels is possible, the unit will be switched on/off by pull string. * The values given in the table for the noise level reflect the levels measured at a position 1 m in front of and 0.8 m below the unit in anechoic chamber Lossnay LGH-Series Ceiling Suspended Systems Model LGH-40ES-E LOSSNAY-LGH-SERIES MODEL REFERENCE LGH-40ES-E , 1, 50 (V, PHASE,HZ) POWER INPUT (W) low 88 high 138 RUNNING CURRENT (A) low 0.4 high 0.6 AIRFLOW (m3/h) low 250 high 400 STATIC PRESSURE (Pa) low 10 high 40 NOISE* db(a) low 33 high 42 TEMPERATURE RECOVERY low 70 (%) EFFICIENCY high 60 ENTHALPY RECOVERY low 52 (%) EFFICIENCY high 45 WEIGHT (kg) 25 DIMENSIONS (mm) WIDTH 900 DEPTH 693 HEIGHT 255 DUCT SIZE (mm) 2 x 200 ø OPTIONAL PARTS MODEL REFERENCE PZ-03SLP-E Switch ON/OFF and Airflow * The values given in the table for the noise level reflect the levels measured at a position 1 m in front of and 0.8 m below the unit in anechoic chamber Compact Design A mere 255 mm from front to back, this thin design takes up a minimum of space even when suspended from the ceiling of an existing building. Minimal installation needs In addition to this lightweight and compact design, connection to the outdoor unit requires just a 200 mm. Saves energy The simultaneous intake/exhaust of air together with the Lossnay core recovers temperature and humidity from the room while ventilating, making this unit both economical and environmentally friendly. A refined design Designed to eliminate the outflow of air to the space directly beneath the unit, there is no worry of discomfort from drafts. 96
97 Lossnay LGH-Commercial Series Models LGH-15 to 200 RX Saves between 20% and 50% of the energy that would otherwise be lost by ventilation Saves up to 30% on initial capital costs of heating and cooling plant due to Lossnay s ability to utilise heating or cooling energy that would otherwise be wasted Automatically humidifies or dehumidifies incoming air to match required interior conditions Supply air and exhaust air are kept strictly separated to ensure inbound air is always fresh Supply air is heated or cooled as required to match room conditions Provides comfortable ventilation through introduction of fresh air, helping to provide a healthy working environment Minimal Maintenance Easily replaced Lossnay element LOSSNAY-LGH-SERIES MODEL REFERENCE LGH15RX LGH25RX LGH35RX LGH50RX LGH80RX LGH100RX LGH150RX LGH200RX (V,PHASE,Hz) ,1, ,1, ,1, ,1, ,1, ,1, ,1, ,1,50 RUNNING CURRENT (A) POWER INPUT (W) Low Medium High*** AIRFLOW Low (m 3 /h) Medium High*** STATIC PRESSURE (Pa)* Low Medium High*** NOISE** Low db(a) Medium High*** EFFICIENCY % Low Medium High*** WEIGHT (kg) DIMENSIONS (mm) Width Depth Height DUCT SIZE (mm) 100ø 150ø 150ø 200ø 250ø 250ø 350ø 350ø *** Refering to the airflow in the table *** The values given in the table for the noise level reflect the levels measured at a position 1.5 m below the unit in anechoic chamber *** Extra high ventilation step to increase stat. pressure ACCESSORIES LOSSNAY MODEL REFERENCE DESCRIPTION PZ-41SLB WIRED REMOTE Control for independent operation PZ-52SF Remote Controller for City Multi System 97
98 MJ-E16PX Dehumidifier Easy to operate by LCD display 3 operating modes: low, high and auto protection Air filter Display of defrost Waterlevel visible Large water container (6 L) Automatic stop by overflow Timer: 1 9 hours operation Hygrostat Display of humidity (50%, 60%, 70%) voltage break Automatic restart after Collects up to 16 litres of moisture in a 24 hours period Compact, unobstrusive and quiet in operation Low energy consumption Environment-friendly refrigerant R134a Compact and efficient MJ-E16PX seems unobstrusive and is portable because of its grip and weight (12.9 kg). Additional Advantages Reduces the time of drying your clothes on the line Installation of a hose possible to transport the condensate water MJ-E16PX DEHUMIDIFYING CAPACITY Litres/24 hours 10 C/70% rel. humidity C/60% rel. humidity C/80% rel. humidity 16.0 TECHNICAL DATA Water container (I) 5.0 Auto Stop (I) 5.0 Weight (kg) 12.9 Dimensions (mm) Width 360 Depth 281 Height 569 Supply voltage (V, Phase, Hz) , 1, 50 Power consumption (W) 280 Noise db(a) Low 33 in fan operation High 35 Operating temperature min. 1 C max. 40 C Compressor type Rotary Refrigerant R134 a Colour white MJ-E16PX CONTROL FUNCTIONS Mode button Timer button Control lamp Tank full lamp Defrost lamp Humidity lamp selects low, high and auto press to set operation time 1 9 hours or permanent shows adjustment lights when water tank needs emptying light is on during defrost operation lights when extremely high rel. humidity, audible signal for rel. humidity more than 70% 98
99
100 Mitsubishi and Mitsubishi Electric are trademarks of Mitsubishi Electric Europe B. V. The Company reserves the right to make any variation in specification to the equipment described or to withdraw or replace products without prior notification or public announcement. Mitsubishi Electric is constantly developing and improving its products. All descriptions, illustrations, drawings and specifications in this publication present only general particulars and shall not form part of any contract. All goods are supplied subject to the Company s General Conditions of Sale, a copy of which is available on request. Art. No /2004 MITSUBISHI ELECTRIC EUROPE B.V. AIR CONDITIONING DIVISION GOTHAER STR. 8 D RATINGEN GERMANY TEL.: FAX:
Air Conditioning at its best
Air Conditioning at its best Product range 200/2007 Split and Multi Split Systems Heat Pump Systems VRF Systems Close Control Systems Ventilation Systems with Heat Recovery Roof Top Systems Dehumidifier
york air-conditioning products Residential & VRF News 2015
york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter
Inverter Air Conditioning for Light Commercial Use
Inverter Air Conditioning for Light Commercial Use 02 Cost Saving Comfort An efficient use of time 03 SDISuper Digital Inverter Very efficient energy consumption Keeps down operating costs Heater operation
FULL DC INVERTER SYSTEMS
FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR DESIGN & FLEXIBLE COMBINATION commercial air conditioners SDV4 2011/2012 AIR CONDITIONING 1 WELCOME TO THE WORLD of SINCLAIR AIR CONDITIONERS Company operation
New Deluxe Wall Mounted Heat Pump Series EXTERIOS
New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History
Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE
Hitachi Air Conditioning Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE Contents Page 04 Product Range 08-09 RAC Summit Wall Mounted 10 RAC Shirokuma Wall mounted 11 RAC S Series - Wall
KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle
KSV70HRF RRP AUS $1,709.00 Split System Reverse Cycle air conditioner featuring inverter technology, clean front with LED display, Bio and active carbon filter, 2 way auto swing (up, down), remote (7.1kW
PLA. Advancements in PLA series improve style and performance for ensured indoor comfort. 4-way Ceiling Cassette. Wide Airflow.
13 4-way Ceiling Cassette PLA SERIES Advancements in PLA series improve style and performance for ensured indoor comfort Wide Air Wide-angle outlets distribute air to all corners of the room, ensuring
DUCTED AIR CONDITIONING SOLUTIONS
DUCTED AIR CONDITIONING SOLUTIONS H I G H E N E R G Y E F F I C I E N C Y B A C K E D B Y A 5 Y E A R F U L L P A R T S & L A B O U R W A R R A N T Y DUCTED RANGE WHY CHOOSE FUJITSU? AUSTRALIA S FAVOURITE
Ductless Systemss A COMFORTABLE, CONVENIENT SOLUTION BUILT TO A HIGHER STANDARD. READ ONLY
Ductless Systemss A COMFORTABLE, CONVENIENT SOLUTION BUILT TO A HIGHER STANDARD. READ ONLY Designed and built with the commitment to high-quality craftsmanship you expect from American Standard, our ductless
LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy
LG Air conditioning Company Multi V Water Ⅱ Air Conditioning Academy 1.1 What is Multi V Water II? High Performance Prospect rights Water pipe Refrigerant pipe Indoor unit Beautiful Exterior Convenience
utopia Split Systems DC Inverter 7kW-14kW G8 5kW-25kW
utopia DC Inverter 7kW-14kW G8 5kW-25kW Split Systems Contents Company profile 4 Product range overview 6 Features and benefits 8 DC Inverter 12 Utopia G8 24 Utopia centrifugal 40 Total heat exchanger
DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS
DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS AN EXCELLENT CHOICE IN COOLING, COMFORT AND CONVENIENCE Why choose a Mini-Split system? Installing
1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/
1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/ ISO 9001 ISO 14001 Certified number : 01 100 89394 Certified number : 01 104 9245101 Fujitsu General (Thailand) Co.,
technology innovation, comfort for your home. The perfect blend of
The perfect blend of innovation, & technology comfort for your home. Air conditioning for your home is all about comfort. No matter what Australia s harsh climate can dish out. From summer scorchers to
PRODUCT CATALOG. Indoor Units
PRODUCT CATALOG Indoor Units Life s Good! From installation to maintenance, LG runs more than 60 global air conditioning academies, each provides training for air conditioning professionals. What is LG?
M Series. Room Air Conditioning
M Series Room Air Conditioning The Adaptable M Series Range Available in a variety of options, our M Series range fits in wherever it s needed. Indoor units can be wall or floor mounted. The full M series
Pioneer in sustainability
Pioneer in sustainability Over 100 years ago Carrier helped pioneer a new industry, and in the last two decades we have pioneered environmentally sensitive products with a reduced impact on the environment.
MULTISPLIT SYSTEMS AIR CONDITIONING SYSTEMS
MULTISPLIT SYSTEMS AIR CONDITIONING SYSTEMS POER, FLEXIBILITY, RESIDENTIAL Carrier presents the new line of multi-split systems A complete and flexible range designed to meet every residential and light
Samsung Room Air Conditioning
Samsung Room Air Conditioning Air Conditioning Solutions from a Trusted Brand At the heart of family living is the home, a place full of special moments and wonderful memories where families live and
FTXS. Wall Mount Heat Pump or Cooling Only
FTXS Wall Mount Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FTXS SkyAir systems feature streamlined, wall mounted indoor units paired with quietly compact outdoor units. Available in both
FHQ. Ceiling Suspended Heat Pump or Cooling Only
FHQ Ceiling Suspended Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FHQ ceiling suspended SkyAir systems are ideal for applications without false ceilings. Installed from the structure, this
Trane Ductless Systems. Get comfortable with a smart solution. READ ONLY
Trane Ductless Systems Get comfortable with a smart solution. Trane Ductless Systems. A smart solution for efficient comfort, where and when you need it. Trane has a tradition of quality lasting more than
-~ available. Power consumption during operation is substantially less than that of lower rated
Introduction Specifically designed for small to medium sized areas the SANYO SAP range is the ideal solution when you need quiet, efficient room air conditioning to create a comfortable environment within
Air Conditioning for Small and Medium-size Buildings
Air Conditioning for Small and Medium-size Buildings Defining a HIGHER standard The all-new MiNi-SMMS air conditioner lineup lets you cool or warm as many as 12 *1 rooms with a single system. Outdoor units
Models Monozone/Multizone (NH4/QH4) Summit (YH4) Big Flow (GH4/G4) New Air Exchanger (JX4)
room air conditioners Models Monozone/Multizone (NH4/QH4) Summit (YH4) Big Flow (GH4/G4) New Air Exchanger (JX4) Contents Company profile 4 Product range overview 6 Standards and quality certificates 8
2015 / 16. price list. Airconditioning systems
2015 / 16 price list Airconditioning systems TERMS OF BUSINESS General As far as nothing else has been declared, the general terms of business and the agreed purchase conditions including the sales discounts
FTQ. Daikin Inverter Ducted Heat Pump
FTQ Daikin Inverter Ducted Heat Pump A TRADITIONAL CENTRAL AIR SYSTEM MADE BETTER WITH DAIKIN CONSTANT COMFORT INVERTER TECHNOLOGY. The Daikin Inverter Ducted Heat Pump line is a cost effective alternative
m-series Ultimate comfort where it matters most Mseries.MrSlim.ca PRODUCT CATALOGUE
PRODUCT CATALOGUE Ultimate comfort where it matters most m-series AIR CONDITIONERS & HEAT PUMPS Mseries.MrSlim.ca *When installed by an authorized HVAC (Heating, Ventilating, and Air Conditioning) installer.
Unico Inverter. Unique and efficient.
Unico Inverter. Unique and efficient. INTERNATIONAL PATENT PENDING The first fixed air conditioner without outdoor unit featuring DC Inverter technology. Great performance, reduced consumption. Designed
FBQ. DC Duct Heat Pump or Cooling Only
FBQ DC Duct Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FBQ DC Duct systems offer a powerful solution, compact in design and easily concealed in a ceiling. With both cooling only and heat
FCQ. Roundflow Cassette Heat Pump or Cooling Only
FCQ Roundflow Cassette Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FCQ roundflow cassette SkyAir systems are ideal for open plan applications where variances in temperature and airflow
AIR-CONDITIONER SPLIT TYPE
FILE NO. A08-016 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE RAS-M10PKVP-E, RAS-M13PKVP-E, RAS-M16PKVP-E, RAS-M18PKVP-E / RAS-M10PKVP-ND, RAS-M13PKVP-ND, RAS-M16PKVP-ND, RAS-M18PKVP-ND / RAS-3M26GAV-E1,
LG Electronics AE Company, Commercial Air Conditioning
www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,
Air Movement. Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners. Pg 83 84 85 85 86 88 89 90
6 Air Movement Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners Pg 83 84 85 85 86 88 89 90 83 Air Movement JKI Heaters Aurora Bathroom Heater Quartz 2
Contents. Part 1 General Information... 1. Part 2 Outdoor Units... 9. Part 3 Installation... 50. Part 4 Troubleshooting 73
MCAC-VTSM-2013-03 R410a Full DC Inverter Mini VRF Contents Part 1 General Information... 1 Part 2 Outdoor Units... 9 Part 3 Installation... 50 Part 4 Troubleshooting 73 Part 5 Control System... 100 Manufacture
The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity
Liebert HPF The High Performance Floormount Indoor Package Cooling Solution Precision Cooling for Business-Critical Continuity We re Emerson Network Power, backed by Emerson, a global company that brings
Consumer Guide. Split System: Wall Mounted Inverter Heat Pumps
Consumer Guide Split System: Wall Mounted Inverter Heat Pumps 6 6 Another Hitachi Day Imagine choosing your perfect day then instantly creating it in the comfort of your own home. With Hitachi heat pumps
Models Utopia ES Utopia IVX Utopia DC Inverter Utopia Fixed Speed Utopia Centrifugal
Utopia Split Systems Models Utopia ES (7.1-14 kw) Utopia IVX (7.1-30 kw) Utopia DC Inverter (5-14 kw) Utopia Fixed Speed (6.3-12.5 kw) Utopia Centrifugal (12.5-25 kw) Contents Company Profile 4 Utopia
hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &
hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS
IR410AI. The flexible solution. Simple, one touch control
The flexible solution The new SANYO Flexi Multi range of heat pump multi split systems are the ideal, flexible solution for providing quiet and efficient air conditioning to 2, 3 or 4 areas from a single
LG AIR CONDITIONING SYSTEMS
LG AIR CONDITIONING SYSTEMS THE NEW STANDARD IN COMFORT INNOVATIVE COMFORT SOLUTIONS AT LG, WE BELIEVE COMFORT SHOULD ALWAYS BE BEAUTIFUL. 4 Table of Contents INTRODUCTION 04-07 ART COOL 08-11 SINGLE
ECO-AIR AIR CONDITIONING www.northamericanhvac.com
INDEX ACCESSORIES INSTALLATION... 3-7 LINE SETS... 3-7 GEOTHERMAL... 3-8 WIRING CABLE... 3-8 CIRCULATOR PUMPS (PRO-TECH MODEL)... 3-9 DC INVERTER SINGLE ZONE HEAT PUMP... 3-6 DC INVERTER TECHNOLOGY...
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient
Inverter Air Conditioning for Light Commercial Use
Inverter Air Conditioning for Light Commercial Use Index Introducing Light Commercial 4 SDI-Super Digital Inverter 6 DI-Digital Inverter 7 DI Big 8 SDI-Super Digital Inverter & DI-Digital Inverter Lineup
SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI R410A Models Indoor unit Outdoor unit AB*14LBAJ AB*18LBAJ AB*F14LAT
All the best brands all under one roof
All the best brands all under one roof Year round comfort and energy efficiency The air conditioner you choose today is going to be with you for a long time, so it s important to choose wisely. The best
Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes
Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,
P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP
P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP www.mitsubishielectric.ca P-SERIES The Attraction of Being Untraditional The Mr. Slim P-Series is a hard worker. It s a commercial-grade ductless
Installation, operation and maintenance manual TX 35A
Installation, operation and maintenance manual TX 35A Rev.10 may 2012 Page 1 of 18 1.0.0 Table of contents INSTALLATION, OPERATION AND MAINTENANCE MANUAL...1 1.0.0 TABLE OF CONTENTS...2 2.0.0 ILLUSTRATIONS...2
For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System
For Residential & Light Commercial Applications 4 Ton 8 Zone Multi Split Heat Pump System EXPERTISE AND INNOVATION The Super Multi PLUS Split System is the ultimate, flexible solution for individual zone
Gree Solar Hybrid Hi Wall Inverter Air Conditioner
Gree Solar Hybrid Hi Wall Inverter Air Conditioner Utilize the natural power of the sun to heat or cool your home. Find out more at www.greeonline.com Why Choose a Solar Hybrid Inverter? The new Gree Solar
SiBE12-625. D-Series / E-Series. [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump
SiBE12-625 D-Series / E-Series [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump SUPER MULTI NX D-Series / E-Series Cooling Only Indoor Unit FTKS20D3VMW FTKS20CAVMB FDKS25CAVMB
Air Conditioning and Ventilation Products Single and Multi-Split Systems, VRF and Lossnay
LIVING ENVIRONMENT SYSTEMS Air Conditioning and Ventilation Products Single and Multi-Split Systems, VRF and Lossnay Price list 2012/2013 for specialist trade companies and planners About this catalogue
USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA
USER S MANUAL FH052EAV1 FH070EAV1 E HNIKA PORTUGUÊS ENGLISH ESPAÑOL ITALIANO DEUTSCH FRANÇAIS System Air Conditioner (Cooling and Heating) E S F I P D G DB98-29263A(1) Safety Precautions Register your
ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.
ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2
2009 AIR CONDITIONING
2009 AIR CONDITIONING PANASONIC AIR CONDITIONING DESIGNED TO CARE FOR YOU AIR CONDITIONING 2009 ECO IDEAS FOR PRODUCTS We will produce energy-efficient products Target To increase the number of products
LOCAL AIR-CONDITIONERS
LOCAL AIR-CONDITIONERS Local air-conditioners Compact Design Split Design Compact Air-Conditioner Quality with systems REMKO THE CUSTOMER-ORIENTED SYSTEM SUPPLIER FOR THE WHOLE YEAR THROUGH From the development
HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT
UP TO 15 SEER Performance MINI-SPLIT SYSTEM UNITS AIR CONDITIONING AND HEAT PUMPS COMPLETE ROOM COMFORT WITH EASY-TO-USE REMOTE CONTROL HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT The Goodman brand offers
Trane Ductless Systems. Get comfortable with a smart solution. READ ONLY
Trane Ductless Systems Get comfortable with a smart solution. Trane Ductless Systems. A smart solution for efficient comfort, where and when you need it. Trane has a tradition of quality lasting more than
AIR CONDITIONING and HEAT PUMP PRODUCTS
AIR CONDITIONING and HEAT PUMP PRODUCTS February 2015 The History of Panasonic Air Conditioning The Panasonic Air Conditioning Group has grown into a global company through its continuous quest for product
INVERTER IN-CEILING CASSETTE. Ideal for various applications including the lounge, family room, restaurants, hotels, offices and meeting rooms.
INVERTER IN-CEILING CASSETTE Ideal for various applications including the lounge, family room, restaurants, hotels, offices and meeting rooms. INVERTER TECHNOLOGY PFC Control in Power Input DC Inverter
CRAC Precision climate control units for data centres
CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have
1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None
1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements
CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability
PFD-P250VM-E PUHY-P250YJM-A(-BS) PUHY-P500YSJM-A(-BS) PQHY-P250YHM-A CLOSE CONTROL SYSTEM MITSUBISHI ELECTRIC s Close Control System (PFD series) is specifically designed for computer rooms, laboratories
SALES BULLETIN. Key Features. New 7 Series Under Ceiling Indoor Units
SALES BULLETIN Key Features 1. Chassis completely re designed 2. Increased product range, now includes 6HP model 3. New features to enable easy installation a. Easy access hanger b. Easier wiring connections
2010 Duct-Free Splits Line Card
2010 Duct-Free Splits Line Card Right Product for the Right Application 2010 Duct-Free Splits Right Product for the Right Application 1:1 2:1 to 4:1 9-24K High Walls 18-24/36/42/60K High Wall, Cassette,
Mini-Split Air Conditioners and Heat Pumps for Residential and Light Commercial Applications
Mini-Split Air Conditioners and s for Residential and Light Commercial Applications 3 TABLE OF CONTENTS FEATURES Mini-Splits Defined... 4 Individual Zoning... Comfort Solution... 8 Energy Efficient...
Introduction To VRF: System Overview, Applications, & Savings Opportunities
Introduction To VRF: System Overview, Applications, & Savings Opportunities System Overview What is VRF? Zoning System Two-Pipe / Three Pipe System Packaged DDC Control Operates as a Heat Pump Simultaneous
Earth can hardly wait for a change in the atmosphere. Nor can we. By making air conditioning supremely energy-efficient, quiet, easy to install, and
1 Earth can hardly wait for a change in the atmosphere. Nor can we. By making air conditioning supremely energy-efficient, quiet, easy to install, and cost-effective, Toshiba aims at the heart of growing
innovative comfort solutions
engineering and specifications Guide duct-free air conditioning systems Art cool inverter flex multi-split floor standing ceiling cassette PTAC PTHP through-the-wall innovative comfort solutions 1 AT LG,
Air Conditioning For Large Buildings
Air Conditioning For Large Buildings Index Introduction 3 Industry leading energy savings 6 New smart & sensitive VRF control 10 Industry leading layout flexibility 14 Other features 18 Outdoor units Outdoor
AIR CONDITIONERS ROOF TOP & UNDERBUNK INSPIRED BY COMFORT NEW RELEASE DOMETIC FRESHJET
AIR CONDITIONERS ROOF TOP & UNDERBUNK INSPIRED BY COMFORT NEW RELEASE DOMETIC FRESHJET 2 HOW AIR CONDITIONING WORKS Air s work on basically the same principle as the cooling units of kitchen refrigerators.
Heat Pump Product Brochure 2015/2016. Premier Series Hi-Wall Split Systems. Everyday Comfort
Heat Pump Product Brochure 2015/2016 Premier Series Hi-Wall Split Systems Everyday Comfort Everyday Innovation We design with you in mind. You ll find that Haier Heat Pump units are quiet, efficient and
AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.
AquaFREE System Technical Catalogue Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.5/6)H(1/3) Specifications in this manual are subject to change without notice
AIR DEHUMIDIFYING 2011. Condensation drying for industry and trade
AIR DEHUMIDIFYING 2011 Condensation drying for industry and trade Condensation drying for industry and trade 2011 DH 18 domestic dehumidifiers Development, production and sales: All from a single source
Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75
Specifications COOLING ONLY / HEAT PUMP 005 006 007 Capacity (Eurovent) Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Nominal input (Eurovent) Cooling kw 1.89 2.35 2.95 Heating kw 1.97 2.24 2.83 EER
Split units TH with hermetic compressors
Split units TH with compressors Refrigeration units in split variant. Available with screw or solder terminal. Condensing unit with sound insulated weatherproof housing for outdoor installation. Split
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
Air Conditioning & Heat Pump Products
Air Conditioning & Heat Pump Products Preliminary Revised April 06 SANYO Air Conditioners & Heat Pumps Btu/h 9,000 12,000 18,000 24,000 26,000 30,000 36,000 42,000 Type Standard Low Ambient Standard Low
R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power
R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor
System. SERVICE MANUAL R410A MODEL : ARNU Series URNU Series
Internal Use Only http://biz.lgservice.com System Indoor Unit R410A SERVICE MANUAL R410A MODEL : ARNU Series URNU Series CAUTI Before Servicing the unit, read the safety precautions in General SVC manual.
Super Modular Multi Design Manual HFC R-410A. Indoor unit. Outdoor unit
Ref.-No. SMMS02-AE-10-05 Indoor unit 4-way ceiling cassette MMU-AP0091H, AP0121H, AP0151H, MMU-AP0181H, AP0241H, AP0271H, MMU-AP0301H, AP0361H, AP0481H MMU-AP0561H 2-way ceiling cassette MMU-AP0071WH,
NEW 3-PIPE ECOi MF2 SERIES
NEW 3-PIPE ECOi MF2 SERIES SIMULTANEOUS HEATING AND COOLING VRF SYSTEM Internet Control Ready INTERNET CONTROL NEW Energy Environmentally friendly refrigerant R410A Down to -20 ºC in heating mode OUTDOOR
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3
SINGLE PACKAGE VERTICAL AIR CONDITIONERS
SINGLE PACKAGE VERTICAL AIR CONDITIONERS AIR CONDITIONERS l HEAT PUMPS l ELECTRIC HEAT QUIETER BY DESIGN SIMPLE TO INSTALL CONCEALED INSTALLATION www.friedrich.com VERT-I-PAK ideal for extended stay properties,
Commercial Air Conditioning Systems
Commercial Air Conditioning Systems 1 Functionality, versatility and comfort for every environment A wide variety of indoor unit designs and outdoor unit capacities ensures the flexibility to meet the
The ABC s of VRF: A Green HVAC Technology An Ideal Green School Solution. Presented by: Fujitsu General America, Inc.
The ABC s of VRF: A Green HVAC Technology An Ideal Green School Solution Presented by: Fujitsu General America, Inc. What to look for in a Green HVAC solution? What if your HVAC system could provide Individual
Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System
Auxiliary HVAC RAM ProMaster Standard Tie-in Extreme Climate System Auxiliary HVAC High performance aftermarket heating and cooling systems engineered for vehicle specific platforms that minimize install
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.
HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET. AFFORDABLE SOLUTIONS FROM AMERISTAR. We know that heating and cooling systems can be a major investment for homeowners. Our goal is
LG Duct-Free Split Systems Product Overview. LG comfort solutions that you never thought possible
LG Duct-Free Split Systems Product Overview LG comfort solutions that you never thought possible TABLE OF CONTENTS Company Introduction Introduction 4 Duct Free System Introduction 6 Key Features 8 Duct-Free
Operating Instructions Split System Air Conditioner
Operating Instructions Split System Air Conditioner Model No. Indoor Unit Type Indoor Unit Type Nominal Capacity 26 36 F2 Low Silhouette Ducted S-26PF2U6 S-36PF2U6 Connectable outdoor unit lineup This
emura Form. redefined.
emura Form. function. redefined. IT S ALL ABOUT DESIGN if award Daikin Europe N.V. is proud to announce that Daikin Emura has been awarded an if Product Design Award for 2010. For 56 years, the if product
elcome to the era of the SEER seasonal efficiency Product range
elcome to the era of the SEER seasonal efficiency Product range Daikin leads the way: Seasonal series Daikin again leads the industry with their full light commercial range optimised for seasonal efficiency,
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion
How To Control A Car With A Power Unit
2014 Catalogue Table of contents NEW REGULATION AND STANDARDS 8 PAGE OUR UNIQUE SOLUTIONS 12 AIRWELL RESIDENTIAL SERVICE 22 HISTORY 24 ICON GUIDE 26 MONOSPLIT DCI RANGE 28 HJD High wall mono & premium
Multi Air Conditioning System for Buildings
Multi Air Conditioning System for Buildings 6, Suenaga, Takatsuku, Kawasaki 238502, Japan http://www.fujitsugeneral.com/ ISO 900 ISO 400 ISO 900 ISO 400 Certified number : 0 00 89394 Certified number :
Room Air Conditioners
Room Air Conditioners Contents Air conditioning systems from Hitachi: quality, efficiency and durability Freely translated Hitachi means A man sees the sunrise as a sign of the start of a better future.
SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS
SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER INDOOR UNIT AH-129 AH-MP14 OUTDOOR UNIT AU-129 AU-MP14 CONTENTS SPECIFICATIONS...2 EXTERNAL DIMENSIONS...4 WIRING DIAGRAMS...5 ELECTRICAL PARTS...6 MICROCOMPUTER