1 VRF Variable Refrigerant Flow System CATALOGUE HEAT PUMP & HEAT RECOVERY for Europe

2 Fujitsu General have been developing and manufacturing high quality and energy efficient products for more than 35 years. Using the latest Japanese technology and state of the art expertise, our products have been designed in accordance with our policy to create the most comfortable environment possible. Our History... 4 Quality Development & Production Environment... 6 AIRSTAGE TM New Products... 8 AIRSTAGE TM Lineup... 0 Indoor units range... 2 AIRSTAGE TM Support... 4 Design Support Tool... 6 The AIRSTAGE TM series provides high energy savings, comfort, and reliability to the end user. The design, installation, and servicing were developed based on the concepts of high flexibility and simplicity. We offer an abundant VRF system lineup to match regional and customer needs by providing the best combination from low to high capacities and from giving priority to conserving installation space to giving priority to high efficiency. AIRSTAGE TM SOLUTION HIGH ENERGY EFFICIENCY MORE COMFORT HIGH RELIABILITY DESIGN FLEXIBILITY EASY INSTALLATION EASY SERVICE & MAINTENANCE... AIRSTAGE TM SERIES HEAT RECOVERY TYPE AIRSTAGE TM VRII HEAT PUMP TYPE AIRSTAGE TM VIII HEAT PUMP TYPE AIRSTAGE TM VII HEAT PUMP TYPE AIRSTAGE TM JIII HEAT PUMP TYPE AIRSTGAE TM JIIS Space saving combination 8HP to 48HP / 2 models Energy efficiency combination 6HP to 44HP / 3 models 8HP54HP 39 Space saving combination 8HP to 54HP / 24 models INDOOR UNITS Compact Cassette... Cassette Mini Duct Slim Duct / Slim Concealed Floor Medium Static Pressure Duct Static Pressure Duct Energy efficiency combination 6HP to 46HP / 5 models Space saving combination 8HP to 48HP / 2 models Energy efficiency combination 6HP to 44HP / 2 models 6 Large Airflow Duct Floor/Ceiling Ceiling... Wall mounted (EEV Internal / external )... CONTROL SYSTEMS CONTROL SYSTEM OVERVIEW WIRING SYSTEM COMPARISON TABLE OF CONTROLLERS... 9 Individual Controller Centralized Controller Convertor / Adaptor Service & Maintenance Tool... 4 P34 P42 P48 P54 P58 Ventilation... 8 Option Reference

3 N E W JIII series efficiency and small capacity model 4HP to 6HP /Heat pump 54 FUJITSU GENERAL s VRF AIRSTAGE TM Series has been developed based on our longterm airconditioning technology knowhow and was first provided 4 years ago. We have offered a series of products from large homes to largescale buildings to meet the various market needs. For Coercial Use For Residential & Light Coercial Use Established as Yaou Shouten Ltd. Air conditioner exports to Middle East. S series 0HP / Heat recovery & Heat pump 0HP / Heat recovery 8,0HP / Heat pump & J series 6HP / Heat pump V series 8 to 42HP / Heat pump VII series efficiency and Compact design model Extensive lineup from 8HP to 48HP in 2HP increment / Heat pump 48 JII series efficiency and small capacity model 4HP to 6HP / Heat pump VRII series efficiency and Compact design model 8 to 48HP / Heat Recovery JIIS series efficiency and compact design model 4HP to 6HP / Heat pump 58 VIII series efficiency and large capacity model Extensive lineup from 8HP to 54HP in 2HP increment / Heat pump Certification Acquisition of New Product Initiatives Fujitsu introduced inverter technology which used R40A refrigerant. RoHS Compliant Restriction of Hazardous Substances (ROHS) is an EU directive on the restriction of the use of certain hazardous substances in all consumer electrical and electronic equipment. DC Inverter Compressors Use of 00% inverter driven DC compressors. 998 : Fujitsu General (Shanghai) Co.,Ltd. 999 : Fujitsu General (Thailand) co.,ltd : FGA (Thailand) Co.,Ltd : Fujitsu General Central Airconditioner (Wuxi) co.,ltd. 4 5

4 The HeadquartersR&D Center (Japan) is equipped with a wide range of testing equipment envisioning a variety of operating conditions. This includes a testing tower with a 60m height difference for buildings. We provide high quality & reliable products that meet the customers' needs from all over the world through this advanced R&D Center and 6 factories based in China and Thailand. Advanced Research Facility and Equipment Performance testing Testing Laboratory Fujitsu General EMC Laboratory Limited Sound testing Fujitsu General Central Airconditioner (Wuxi) Co., Ltd. Air flow testing Calorimeter testing Transportation & Handling Fujitsu General (Shanghai) Co., Ltd. Fujitsu General Limited Vibration testing Compressibility testing International Test Site for EMC Regulation Reliability Testing 60m Height Difference Testing Tower Fujitsu General (Thailand) Co., Ltd. Fujitsu General Engineering (Thailand) Co., Ltd. Objective is to Confirm Oil Circulation of Compressor for Reliability Severe environmental testing Water shower testing FGA (Thailand) Co., Ltd. Certifications Acquisition of ISO 900 and ISO400 in each factory 6 7

5 New Small VRF Series Mini Duct Models: ARXK07/09/2/4/8/24GCLH (With drain pump) N E W 4/5/6 HP class Single phase / 3 phase 6 models 7 to 24 class 6 models efficiency Compact design of Depth 450 and Height 98 Installation is possible even in narrow ceiling space N E W In spite of compact model, Vshaped heat exchanger, large fan casing, and optimized airflow path achieve significant low noise. ARXK07/09/2/4 ARXK8 ARXK24 Static Pressure Duct Model: ARXC96GATH N E W These indoor units allow for high airflow quantities 96 class high energy efficiency Wide static pressure range of 0 to 0Pa 5 static pressures selection New Tropical VRF Series (Production by order) 2HP to 54HP 39 models Tropical VRF is designed for tropical weather. Possibe to operate cooling up to 52 C ambient temperature. Heavy anticorrosion treatment design Controllers Supported languages are increased for Wired Remote Controller (Touch Panel) New function (option) is added for Touch Panel Controller Wired Remote Controller (Touch Panel) UTYRNRYZ N E W Corresponds to 2 different languages Touch Panel Controller UTYDTGYZ N E W N E W Electricity charge apportionment function added (option) Convertors Network Convertor can be connected to single split 2 types of DC power supply type and AC power supply type are available Modbus convertor can be connected to Modbus network Network Convertor: UTYVTGX (DC power supply type) N E W UTYVTGXV (AC power supply type) N E W Network Convertors offer total solutions for multiple airconditioning systems control. MODBUS Convertor UTYVMGX N E W VRF System can be integrated with the Building management system supported by MODBUS. UTYVTGX UTYVTGXV UTYVMGX 8 9

6 Fujitsu General provides multi air conditioning systems for buildings AIRSTAGE Series matched to the size and application of the property. 8HP48HP 8HP54HP 8HP48HP 4HP, 5HP, 6HP 4HP, 5HP, 6HP 34 models 39 models 33models 6 models 3 models Heat Recovery type for simultaneous heating and cooling operation Heat Pump type for heating or cooling operation Systems compatible with individual operation mode control, as well as large offices, hotels, and large composite facilities Systems for large offices, hotels, and large composite facilities Extensive lineup from 8HP to 54HP increment connectable indoor unit capacity ratio up to 50% Space saving and Energy efficiecy combinations 39 models lineup Extensive lineup from 8HP to 48HP increment connectable indoor unit capacity ratio up to 50%. Space saving and Energy efficiecy combinations 34models lineup. Heat Pump type for heating or cooling operation Systems for large offices, hotels, and large composite facilities Extensive lineup from 8HP to 48HP increment connectable indoor unit capacity ratio up to 50% Space saving and Energy efficiecy combinations 33 models lineup Heat Pump type for heating or cooling operation Heat Pump type for heating or cooling operation Systems for large homes to medium sized offices, shops Small capacity range from Systems for large homes to medium sized offices, shops Small capacity range 4HP to 6HP connectable indoor unit capacity ratio up to %. Energy efficiency 3models lineup from 4HP to 6HP connectable indoor unit capacity ratio up to % Space saving design 3 models lineup Outdoor units range HP class Space saving AJYA72GALH AJYA90GALH AJY08GALH AJY26GALH AJY44GALH AJY62GALH AJYGALH AJY98GALH AJY26GALH AJY234GALH AJY252GALH AJY270GALH AJY288GALH AJY6GALH AJY324GALH AJY342GALH AJY360GALH AJY378GALH AJY396GALH AJY44GALH AJY432GALH Heat Recovery Efficiency AJY44GALHH AJY98GALHH AJY26GALHH AJY234GALHH AJY252GALHH AJY270GALHH AJY288GALHH AJY6GALHH AJY324GALHH AJY342GALHH AJY360GALHH AJY378GALHH AJY396GALHH Space saving AJY072LALBH AJY090LALBH AJY08LALBH AJY26LALBH AJY44LALBH AJY62LALBH AJYLALBH AJY98LALBH AJY26LALBH AJY234LALBH AJY252LALBH AJY270LALBH AJY288LALBH AJY6LALBH AJY324LALBH AJY342LALBH AJY360LALBH AJY378LALBH AJY396LALBH AJY44LALBH AJY432LALBH AJY450LALBH AJY468LALBH AJY486LALBH Heat Pump Efficiency AJY44LALBHH AJY62LALBHH AJYLALBHH AJY26LALBHH AJY234LALBHH AJY252LALBHH AJY270LALBHH AJY288LALBHH AJY6LALBHH AJY324LALBHH AJY342LALBHH AJY360LALBHH AJY378LALBHH AJY396LALBHH AJY44LALBHH AJY26LALH AJY234LALH Space saving AJYA72LALH AJYA90LALH AJY08LALH AJY26LALH AJY44LALH AJY62LALH AJYLALH AJY98LALH AJY252LALH AJY270LALH AJY288LALH AJY6LALH AJY324LALH AJY342LALH AJY360LALH AJY378LALH AJY396LALH AJY44LALH AJY432LALH Heat Pump Efficiency AJY44LALHH AJY98LALHH AJY26LALHH AJY234LALHH AJY252LALHH AJY270LALHH AJY288LALHH AJY6LALHH AJY324LALHH AJY360LALHH AJY378LALHH AJY396LALHH Efficiency NEW (Single phase) AJY040LBLAH AJY045LBLAH AJY054LBLAH Heat Pump Efficiency (3 phase) AJY040LELAH AJY045LELAH AJY050LELAH Heat Pump Space saving AJY040LCLAH AJY045LCLAH AJY054LCLAH 0 * Production by order VIII tropical series: Possible to operate up to 52 C outdoor temperature. Heavy anticorrosion treatment design. Capacity range 8 HP (AJY072LNLBH) to 54 HP (AJY486LNLBH). 39 models

7 Indoor units range Comprehensive range of indoor units of variety design and capacity ranges available which can be selected to suit any air conditioning needs. 2 types, 66 models, Capacity range from. to 28.0 Model code Capacity range () Compact Cassette AUXB04GALH AUXB07GALH AUXB09GALH AUXB2GALH AUXB4GALH AUXB8GALH AUXB24GALH Cassette Cassette (Slim type) AUXD8GALH AUXD24GALH Cassette (Large type) AUXA8GALH AUXA24GALH AUXAGALH AUXA34GALH AUXA36GALH AUXA45GALH AUXA54GALH Mini Duct N E W (With drain pump) ARXK07GCLH ARXK09GCLH ARXK2GCLH ARXK4GCLH ARXK8GCLH ARXK24GCLH Slim Duct (With drain pump) ARXD04GALH ARXD07GALH ARXD09GALH ARXD2GALH ARXD4GALH ARXD8GALH ARXD24GALH Duct Medium Static Pressure Duct ARXA24GBLH ARXAGBLH ARXA36GBLH ARXA45GBLH N E W Static Pressure Duct ARXC36GBTH ARXC45GATH ARXC60GATH* ARXC72GBTH* ARXC90GBTH* ARXC96GATH* Large Airflow Duct ARXN8GATH* 2 ARXN24GATH* 2 ARXNGATH* 2 ARXN34GATH* 2 ARXN36GATH* 2 ARXN45GATH* 2 Floor (Same as Ceiling models) Floor ABYA2GATH ABYA4GATH ABYA8GATH ABYA24GATH Slim Concealed Floor (Same as Slim Duct models) ARXD04GALH ARXD07GALH ARXD09GALH ARXD2GALH ARXD4GALH ARXD8GALH ARXD24GALH Ceiling Ceiling ABYA2GATH ABYA4GATH ABYA8GATH ABYA24GATH ABYAGATH ABYA36GATH ABYA45GATH ABYA54GATH Wall Mounted Wall Mounted ASYA04GACH ASYA07GACH ASYA09GACH ASYA2GACH ASYA4GACH ASYA8GACH ASYA24GACH ASYAGACH Wall Mounted (EEV external) ASYE04GACH ASYE07GACH ASYE09GACH ASYE2GACH ASYE4GACH With this model, connection of EV kit is necessary. *: ARXC60/72/90/96G cannot be connected to JIIS series and JIII series. *2: Large Airflow Duct can be connected to VIII series only. Energy Recovery Ventilator range Outdoor Air Unit range Airflow rate (m3/h) Airflow rate (m3/h) Model code Model code Energy Recovery Ventilator Outdoor Air Unit UTZBD025B UTZBD035B UTZBD050B UTZBD0B UTZBD00B ARXH054GTAH ARXH072GTAH ARXH096GTAH 2 3

8 Fujitsu General provides a variety of product and technology information to engineers and consultants and also conducts new product research and design support activities. We provide a wide range of support to maintain high quality from design to installation. Product information New product information is provided in the form of documents and movies for each model to match the release timing. These can be downloaded from a special website, so please contact our dealer nearest you. Features Product News Brochures & All Manuals Feature Promotion Movie Head Office Trainingng Center Japan Europe Training Center UK China Training Center China Europe Training Center Germany Technical Information Asia Training Center Singapore America Training Center U.S.A. We provide information helpful for design. We also provide information and tools that are useful for air conditioning system design, such as unit performance data and tools that make it easy to select models and create estimates. Features Design & Technical Manual Model Selection & Estimation Certificate Data 2D/3D CAD Data Middle East Training Center UAE Oceania Training Center Australia Training Technical Support Fujitsu General has built the training facilities in many locations around the world that regularly engage in specialized product, technology, and servicing training. These research facilities also support the development of people with high technical capability. Technological support is provided at every stage from design to installation to maintain the necessary reliability. We cooperate with you to build a better quality air conditioning environment. Features Designing Airstage Systems Control System onsite training Training for installer Presentation & training for dealers 2 Features CFD Simulation Guide line Coissioning Support

9 Design Simulator Building Information Modeling (BIM) Put the charts and pens away and design your projects on your computer with ease using the Design Simulator. Everything from selecting indoor and outdoor units, allocating controls and optional parts to designing the piping and wiring systems is made easier using the program's builtin features. Once your project is designed take advantage of the Export functions to easily get materials lists, product specifications, refrigerant calculations and more it'll even export to Word or Excel formats, and group the relevant CAD data for your project. FUJITSU GENENRAL provides the Building Information Modeling (BIM) object models and contents for our VRF system and some products to the architect, designer and contractor using Autodesk Revit technology from our Website and Autodesk Seek Website, etc. Automatically create model selection information Each unit can be automatically set by entering the required performance, type, and temperature conditions for each indoor unit and then dragging and dropping into the outdoor unit. Piping and wiring diagrams can be created automatically and it is easy to set branches, grouping, and options. 3D and 2D product data We provide 3D data that closely resemble the actual product appearance. 2D CAD design operations are supported and 2D display is also provided. The data can also be output in other formats, such as DXF and DWG, which are used by other design CAD. The additional refrigerant charging amount is automatically calculated when the pipe length is entered. It is also easy to set the remote controller groups, central controller and converters. The equipment list including the equipment information is created automatically. Output the format that matches the application Installation limitation The equipment installation limitation range is shown. Installation requirements, such as distance from the wall, is automatically displayed to make it easy to produce highly reliable layout designs. The information specific to your project can be exported in a number of industry standard file formats. Word format (rtf) Excel format (csv) Auto CAD format (DXF) 2D Data (DXF) 3D Data (RFA) Installation information Other information, such as symbols showing the airflow direction that are required for installation drawings, is built in and can be automatically reflected in 2D drawings. Installation drawings can be created easily. Update your Design Simulator Database can be easily updated online using AutoUpdate function through FTP. User side(pc) Information on the latest history update is demanded. Information on the latest history update replied. FTP server side (PC) Product specifications & Link information Contains the basic information required for air conditioner design, including unit size, capacity, input power, noise, and airflow rate. These data can be procured from the Fujitsu General Website, Design Simulator, and Autodesk Seek Website. 6 7

10 Airstage VRF Systems can be designed to effectively provide an air conditioning solution from a large domestic residence through to a large scale coercial building. 8 9

11 Operation Performance is Effectively Controlled. Room temperature set point limitation ( C) The minimum and maximum temperature ranges can be limited, which provide further energy saving while maintaining the comfort of the occupants Original Set Temp Set point limitation setting Autooff timer New wired remote controller is equipped with an OFF timer function that automatically stops operation when a fixed time has elapsed from the start of operation. This prevents waste of energy. Furthermore a new wired remote controller can set up the interval of time in case operation stops. Set interval time hour (7:00 to 24:00) ON Auto OFF Set off time ( to 240 minutes) 7:00 24:00 OFF Energy saving management ly Energy Efficiency Efficiency is improved significantly by using DC twin rotary compressor, inverter technology, and large heat exchanger. EER COP New model Previous model A variety energy saving operations can be set and managed depending on the season, weather, and time period. Excellent energy saving operation is performed by using System Controller %UP! %UP! %UP! %UP! %UP! %UP! Capacity save operation Operation capacity can be set in 5 steps for rated capability. The power consumption at peak is cut down and the maximum load is suppressed. (Screen image is Energy manager software(option)) Setting range 00% % Capacity Setting level System Controller Capacity save 60% 40% 0 Heat Recovery (0HP) Heat Pump (8HP) Heat Pump (6HP) 0% Time 20 2

12 Precision refrigerant flow control Precise and smooth refrigerant flow control is achieved by using a DC Inverter control in conjunction with individual indoor unit electronic expansion valve control. This allows high precision comfortable temperature control of ±0.5 C. Set temp. Hot Hot Cold ±0.5 C Low Reach the set temperature quickly Thermal change of the room *Simulation in heating operation. Comfortable operation is achieved due to a small variation of room temperature Low sound level design Small capacity indoor units respond for the demands of several applications. These models will be able to offer greater audibility comfort by operating at super low sound levels. Especially, Wall mounted (EEV external) type is 9dB(A) when low mode heating operation. 9dB(A) At low mode heating operation Small capacity indoor unit Quiet operation Low noise mode Two low noise modes can be selected automatically by quiet priority setting and capacity priority setting depending on the indoor environment and outside temperature load. This feature can be controlled via outdoor unit external input and/or system controller. Quiet priority setting Capacity priority setting Auto changeover function Air conditioning load factor Heat load Air conditioning load factor Heat load At Auto setting, the cooling/heating mode is automatically switched according to the set temperature and room temperature. Automatic cooling / heating operation for each room is possible Capacity 00% 0 down Capacity 00% 0 Alternated automatically 2 C 0.5 C Set Temp. 0.5 C 2 C operation time fan operation Dry Room A 24 C Room C 27 C Room D OFF Room B 8 C Room E 23 C Fan Operating sound 58dB 0 time Quiet priority low noise mode Operating sound 58dB 0 Reset automatically Capacity priority low noise mode time operation fan operation Nonstop oil recovery operation Previous model VIII series ( operation) Auto changeover setting allows for the product to easily switch between cooling and heating modes regardless of the operation mode of other indoor units. This can be done via specific indoor unit with wired remote controller. This ensures comfortable operation all year round. Switching to cooling and heating mode by specific remote controller in the main room, etc. A comfortable room condition is maintained during oil recovery mode because the product continues to operate without stopping the cooling or heating operation. *: AIRSTAGE VRII series is not available. ON OFF Operation stopped at oil recovery Time ON Nonstop oil recovery operation Time 22 23

13 Backup operation If one compressor fails, backup operation will be performed by the remaining compressors*. *: Note: Backup operation may not be possible depending on the trouble state. Advanced refrigerant control Innovative compressor control logic has been introduced in order to balance the refrigerant mass flow rate of each outdoor unit by controlling the inverter speed. ON ON ON ON ON OFF DC DC 2 DC 3 DC DC 2 DC 3 Master Slave Slave 2 Balance operation condition Load level Master Slave Slave 2 Unbalance operation condition Outdoor unit rotational operation The compressor starting order is rotated so that the running time is shared. Rotation Liquid flow back protection By adopting a large sized accumulator, the not completely vapourised refrigerant stays inside of the accumulator to ensure no liquid refrigerant is being fed into the compressor. Compressor Completely vapourised refrigerant from Evapolator Large sized Accumulator Liquid refrigerant (stays inside of accumulator) DC DC 2 DC 3 DC DC 2 DC 3 Adoption of blue fin heat exchanger heat exchanger Corrosion resistant of the heat exchanger has been improved by the introduction of blue fin treatment to the outdoor unit s heat exchanger. Cobalt Blue protection Standard chromate protection Aluminium base material Rotation DC DC 2 DC 3 Rotation Hydrophilic coating Note: Rotational operation is alternated by the start / stop timing of the compressor

14 Overall piping length,000m Total pipe length,000m, max. capacity connection 4HP6HP AIRSTAGE TM JIIS Heat Pump type 4HP6HP AIRSTAGE TM JIII Heat Pump type 8HP54HP AIRSTAGE TM VIII series Heat Pump type Actual pipe length m (VRII, VIII) 50m (VII) Height difference between outdoor and indoor units 50m max. For the outdoor unit installed below the indoor units: 40m max. Connectable indoor unit capacity range 50 % *2 to % * Connectable indoor unit number up to 8 Connectable indoor unit capacity range 50 % to 50% * Connectable indoor unit number up to 3 Connectable indoor unit capacity range 50 % to 50% *3 Connectable indoor unit number up to 8HP48HP AIRSTAGE TM VRII series Heat Recovery type AIRSTAGE TM VII series Heat Pump type *. Conditions of maximum connectable indoor unit capacity ratio is as the chart below. *2. Only 4HP is 46% *3. Max. capacities in the combinations including the 8HP outdoor unit fall below 50%. Pipe length from first separation tube to the farthest indoor unit 60m max. (VRII, VII) 90m* max. (VIII) Height difference between indoor and indoor units 5m max. Connectable indoor unit capacity range 50 % to 50% * Connectable indoor unit number up to Connectable indoor unit capacity range 50 % to 50% * Connectable indoor unit number up to 48 Series VII/VRII JIII JIIS Maximum connectable indoor unit capacity ratio Without. models With. models* 4 % 50% 7% 50% 50% % *4. In the case of connectable indoor units,. models and Cassette and/ or Duct type of 9.0 class or more, maximum connectable indoor unit capacity ratio is 0%. *: The limitation on the pipe length between the farthest IU and the nearest IU originated from the first separation tube must be 60m or less. Wide operating range Installation in extreme temperature conditions is possible due to an increase in operational range. static pressure The outdoor unit can have a condenser hood easily connected with a static pressure of Pa to Pa. This allows outdoor units to be installed within plant rooms in high rise buildings. Powerful discharge air prevents a shortcircuit. Previous model VRII, VIII, VII series Pa (VRII, VII) Pa (VIII) Large diameter fan and DC motor has been utilized allowing an external static pressure of Pa to Pa. This is approximately 2.6 times greater than the previous model. AIRSTAGE TM VRII series Heat Recovery type ( C) C 0 C AIRSTAGE TM VII series Heat Pump type ( C) C 5 C * 5 & 2 C 0 C 2 C 20 C 2 C 20 C AIRSTAGE TM VIII series Heat Pump type ( C) C 5 C * 5 2 C 20 C AIRSTAGE TM JIIS & AIRSTAGE TM JIII series Heat Pump type ( C) C 5 C 2 C 20 C *5. Note : When a multiple outdoor unit connection is used, operating range is from 5 C to 46 C in cooling

15 Easily transported Easily craned using lifting belt hooks Design of outdoor unit allows for lifting straps to be used Simple wiring work Installation of the wiring systems is made easier as the counication wiring can be installed continuously between the indoor, outdoor and RB units. or Parallel connection Serial connection Transporting by forklift Transport with forklift is possible. Easy evacuation using vacuum mode function Air Air The vacuum mode function enables all expansion valves of indoor units to be fully opened, making it easy to evacuate all the air inside pipe lines and indoor units. Outdoor unit Air Vacuum pump Can be transported in a small elevator Automatic address setting The address of the indoor unit, RB unit and signal amplifier can be set through the automatic function setting on the outdoor unit PCB. Automatic address setting is performed at outdoor unit Addresses are automatically distributed from outdoor unit. Signal Amplifier Easy access By adopting a LShape front panel that can be removed, the work space for installation and service has been significantly expanded by this new design. For multiple installations, work is performed easily and efficiently even in a narrow space. Expansion of work space RB unit Reduced installation intervals by front access Press the push button switch of outdoor unit Manual address setting from indoor unit and remote controller is also possible. Flexible piping connection Piping and wiring are available to the front, left and right, and bottom. Easy coissioning by Service Tool Service tools can be used to check the refrigerant temperature, pressure, and the operating status of the electronic expansion valve, making it easy to determine whether the units are connected properly. Flexible installation by 4 way pipe direction 28 29

16 Design for Easy Maintenance Mobile trouble shooting tool for iphone Mobile Technician FREE 7 segment LED is used to make it easy to check the details about the function setting status, refrigerant temperature, pressure, compressor operation time, and other factors for each model to make it easy to perform selfdiagnostics. We will release an App of troubleshooting tool for iphone, ipod touch and other Apple products. This application is a troubleshooting tool for FUJITSU GENERAL air conditioner (RAC / PAC, VRF) It helps you to check air conditioner condition. Error code check, Troubleshooting, and Sensor check are available. Error diagnosis by Service Tool Necessary maintenance can be carried out after analysing the operation data. The service tool can be connected anywhere in the VRF network. Outdoor unit Transmission line Service Tool UTYASGX Software Easy to read 7segment LED : Confirm detailed operational and error status without using any specific equipment. Movable PCB panel Easier for maintenance work behind the PCB Indoor unit USB adaptor (Field supplied) Easy to carry out with USB adaptor Equipment Detail (Diagram) Equipment Detail (List) 7segment LED Operation mode status Discharge temperature/pressure status Compressor operation indication Address/type/number of outdoor unit Error status can be checked easily via the indoor unit wired controller An error code is displayed on a liquid crystal screen. Error status can be cheked easily by outdoor unit display Remote monitoring The Web Monitoring system allows you to view system operation anytime over the internet, ensuring issue free operation. Web Monitoring System Wired Remote Controller System number 00: Controller 002: Indoor unit Error code Simple Remote Controller Remote controller address Error code Monitoring Side VRF Network System Side Outdoor unit Transmission line Unit number Wired Remote Controller (Touch panel) Error status / Error history Error and quantity annunciation Internet or Public Telephone Line Web Monitoring Tool Error code USB adapter (Field supplied) Abnormal indoor unit address Indoor unit 3

17 The AIRSTAGE series outdoor units were developed with structural designs and advanced inverter technology to provide higher efficiency. durability technology has also been incorporated to ensure longterm use

18 Features Efficiency in actual operation Top class high COP is achieved for all combinations by our unique heat exchanger structure, high efficient DC twin compressor, and our own technologies. Smart and cutting edge design Extensive lineup from 8HP to 48HP in 2HP increment Connectable indoor unit capacity ratio up to 50% Space saving combination (COP) * (HP) (COP) For 24 HP Combination Space saving Energy efficiency Energy efficiency 4 Simultaneous cooling and heating operation using refrigerant system and heating can be freely selected for each indoor unit to provide simultaneous cooling and heating in rooms with large temperature differences. combination * (HP) COP 2.6% UP Annual cooling operation Use annual cooling operation for the rooms and other spaces that require constant temperature control throughout the year. Handles changes in the temperature difference The operation mode can be freely changed when there are large temperature differences during the day, such as between seasons. Energy saving technology that boosted operation efficiency Powerful large propeller fan By using CFD* technology, a newly designed fan achieves high performance and low noise operation. *. CFD = Computational Fluid Dynamics 3 phase DC fan motor Efficiency is substantially improved by high efficient motor with sophisticated driver control. In addition, low noise is realized by DC fan motor. Large Building Outdoor unit Heat exchanger 4 way valve Compressor pressure liquid Low pressure gas pressure gas RB unit Heat exchanger Indoor unit EEV Our Heat recovery systems achieve high operating energy efficiency by drawing heat from the room to be cooled and transferring it as energy for rooms that are to be heated. Subcool heat exchanger Heat Exchange efficiency is achieved by using an internal projection shape double pipe construction. Sinewave DC inverter control efficiency is realized by adoption of reduced switching loss IPM. efficient compressor Large capacity DC inverter compressor Large capacity high efficient DC twin rotary compressor with excellent intermediate capability. Energy saving of the operating systems has been approved as heating and cooling modes can be operated at the same time on the same air conditioning piping system. COP & Mainly Mainly NoHeat Recovery model (%) ratio 4face heat exchanger Heat exchange efficiency is significantly improved by the introduction of a new 4face heat exchanger that increases effective surface area. Front intake port (corner cut air inhaling structure) In multiple outdoor unit installations, the unique front intake design improves airflow into the Heat Exchanger

19 Features All inverter compressor Flexible piping connection Large capacity DC inverter compressor Large capacity high efficient DC twin rotary compressor with excellent intermediate capability. A more flexible refrigerant piping work is possible by the use of various piping and RB Unit connections, for adjustments to the floor layout and building structure. Separation tube efficient compressor speed control Comfortable space with small room temperature changes and little energy loss is created by 0.Hz steps compressor speed control. Capacity RB Unit (Single type) RB Unit (Multi type) Max.3 or 8 indoor units 0.Hz Application Max. 8 indoor unit Single connection Group connection Individual cooling and heating Simultaneous cooling and heating Single connection & RB Unit less connection*2 Group connection Individual cooling and heating Simultaneous cooling and heating only The RB unit can be freely positioned between the first branch and the indoor unit. The maximum height difference between RB units is 5 m. *2. RB Unit is not necessary for cooling only use. Inverter frequency Flexible installation of RB unit Multiple outdoor operation control Height When multiple outdoor units are connected a sophisticated operation is performed by each compressor. Rather than running one compressor at full load and distributing refrigerant to one heat exchanger, this control method operates all compressors at part load and distributes refrigerant to all of the heat exchangers which allows for the overall system efficiency to be improved. 98 Small & slim design saves space A drain pipe is not required The control box position can be changed to meet the installation conditions Compressor Load level efficient operation Installation possible from either side for freedom of the control box efficient refrigerant flow control Larger refrigerant flow Large intake airflow Small design saves space A drain pipe is not required Simple installation series connection design 2way connection Small intake airflow EEV 36 Installation possible on the upperside for use in narrow space Fan Heat exchanger RB unit (single type) Easy to maintenance in a narrow space Inefficient operation Heat exchanger refrigerant control The heat exchanger in the outdoor unit is split into two parts (Top and Bottom). The efficiency of the heat exchanger has been improved by adopting an optimum refrigerant path control where the refrigerant is distributed more into the top heat exchanger as this is where there is a greater air flow intake. RB unit (multi type) Heat exchanger Distributor Up to 2 units can be connected in series. Maintenance can be performed from the side. Electrics box can be temporarily fixed by sliding down. Parts can be replaced easily even at narrow space in the ceiling. RB unit Ceiling Outdoor unit 37

20 Outdoor units lineup Combinations other than the followings are not recoended. Space saving combination 22.4 (8HP) 28.0 (0HP) 33.5 (2HP) 40.0 (4HP) 45.0 (6HP) Dimensions 8,0,2HP : AJYA72GALH / AJYA90GALH / AJY08GALH 690 (Bolt pitch) (Unit : ) 5 (Bolt pitch) 7 (Hole) AJYA72GALH UNIT : AJYA72GALH AJYA90GALH UNIT : AJYA90GALH AJY08GALH UNIT : AJY08GALH AJY26GALH UNIT : AJY26GALH 50.4 (8HP) 56.0 (20HP) 6.5 (22HP) 67.0 (24HP) 73.0 (26HP) AJY44GALH UNIT : AJY44GALH 732 (Bolt pitch) 9 AJY62GALH UNIT : AJYA90/A72GALH AJYGALH UNIT : AJYA90/A90GALH AJY98GALH UNIT : AJY08/A90GALH AJY26GALH UNIT : AJY08/08GALH AJY234GALH UNIT : AJY44/90GALH 78.5 (28HP) 85.0 (HP) 90.0 (32HP) 95.0 (34HP) 00.5 (36HP) AJY252GALH UNIT : AJY44/08GALH AJY270GALH UNIT : AJY44/26GALH AJY288GALH UNIT :AJY44/44GALH AJY6GALH UNIT : AJY08/08/A90GALH AJY324GALH UNIT : AJY08/08/08GALH 06.5 (38HP) 2.0 (40HP) 8.0 (42HP) 23.5 (44HP).0 (46HP) B A C AJY342GALH UNIT : AJY44/08/A90GALH AJY360GALH UNIT : AJY44/08/08GALH AJY378GALH UNIT : AJY44/44/A90GALH AJY396GALH UNIT : AJY44/44/08GALH AJY44GALH UNIT : AJY44/44/26GALH 4,6HP : AJY26GALH / AJY44GALH (Unit : ) 35.0 (48HP) 000 (Bolt pitch) 840 (Bolt pitch) 7 (Hole) AJY432GALH UNIT : AJY44/44/44GALH 732 (Bolt pitch) Energy efficiency combination (6HP) 62.4 (22HP) 67.2 (24HP) 72.8 (26HP) 78.4 (28HP) 690 AJY44GALHH UNIT : AJYA72/A72GALH AJY98GALHH UNIT : AJY26/A72GALH AJY26GALHH UNIT : AJYA72/A72/A72GALH AJY234LALHH UNIT : AJYA90/A72/A72LALH AJY252GALHH UNIT : AJYA90/A90/A72GALH 84.0 (HP) 90.4 (32HP) 96.0 (34HP) 02.4 (36HP) 08.0 (38HP) B A C AJY270GALHH UNIT : AJYA90/A90/A90GALH 3.0 (40HP) AJY360GALHH UNIT : AJY44/26/A90GALH AJY288GALHH UNIT : AJY26/A90/A72GALH 20.0 (42HP) AJY378GALHH UNIT : AJY26/26/26GALH AJY6GALHH UNIT : AJY26/A90/A90GALH 25.0 (44HP) AJY396GALHH UNIT : AJY44/26/26GALH AJY324GALHH UNIT : AJY26/26/A72GALH AJY342GALHH UNIT : AJY26/26/A90GALH A Front side knockout position 73 Ø Ø 43.7 Ø 50 Ø 22.2 Power supply cable port Power supply cable port Power supply cable port Transmission cable port Ø 22.2 Transmission cable port Pipe port B Left side knockout position Ø 50 Power supply cable port Ø 22.2 Transmission cable port Ø 34.5 Power supply cable port Ø 43.7 Power supply cable port Ø 22.2 Transmission cable port C Bottom side knockout position Pipe port Top view

21 Outdoor units specifications Space Saving Combination Rating Capacity range HP Power source Capacity Unit Unit 2 Unit 3 Maximum Connectable Indoor Unit* Indoor unit connectable capacity Input power EER COP Air flow rate Sound pressure level* 2 Maximum external static pressure Compressor motor output Heat exchanger fin Dimensions Weight Refrigerant Connection pipe diameter Operation range Pa Height Width Depth W/W m 3 /h db (A) kg Type (Global Warming Potential) Charge kg Liquid Discharge Gas Suction Gas C / AJYA72GALH AJYA90GALH AJY08GALH AJY26GALH AJY44GALH AJY62GALH AJYGALH AJY98GALH AJY26GALH AJYA72GALH AJYA90GALH AJY08GALH AJY26GALH AJY44GALH AJYA90GALH AJYA90GALH AJY08GALH AJY08GALH AJYA72GALH AJYA90GALH AJYA90GALH AJY08GALH , to to 2 0 to , to to 2 0 to , to to 2 0 to , , to to 2 0 to phase 4 wire, 400 V, 50Hz , , to to 2 0 to , to to 2 0 to , to to 2 0 to , to to 2 0 to , to to 2 0 to 2 AJY234GALH AJY252GALH AJY270GALH AJY288GALH AJY6GALH AJY324GALH AJY342GALH AJY360GALH AJY378GALH AJY396GALH AJY44GALH AJY432GALH AJY44GALH AJYA90GALH ,000+, , to to 2 0 to 2 AJY44GALH AJY08GALH ,000+, , to to 2 0 to 2 AJY44GALH AJY26GALH , , to to 2 0 to 2 AJY44GALH AJY44GALH , , to to 2 0 to 2 AJY08GALH AJY08GALH AJYA90GALH , to to 2 0 to 2 AJY08GALH AJY08GALH AJY08GALH , to to 2 0 to 2 AJY44GALH AJY08GALH AJYA90GALH phase 4 wire, 400 V, 50Hz ,000+, , to to 2 0 to 2 AJY44GALH AJY08GALH AJY08GALH ,000+, , to to 2 0 to 2 AJY44GALH AJY44GALH AJYA90GALH ,000 2+, , to to 2 0 to 2 AJY44GALH AJY44GALH AJY08GALH ,000 2+, , to to 2 0 to 2 AJY44GALH AJY44GALH AJY26GALH , , to to 2 0 to 2 AJY44GALH AJY44GALH AJY44GALH , , to to 2 0 to 2 Energy Efficiency Combination Rating Capacity range HP Unit Unit 2 Unit 3 Maximum Connectable Indoor Unit* Indoor unit connectable capacity AJY44GALHH AJYA72GALH AJYA72GALH AJY98GALHH AJY26GALH AJYA72GALH AJY26GALHH AJYA72GALH AJYA72GALH AJYA72GALH AJY234GALHH AJYA90GALH AJYA72GALH AJYA72GALH AJY252GALHH AJYA90GALH AJYA90GALH AJYA72GALH AJY270GALHH AJYA90GALH AJYA90GALH AJYA90GALH AJY288GALHH AJY26GALH AJYA90GALH AJYA72GALH AJY6GALHH AJY26GALH AJYA90GALH AJYA90GALH AJY324GALHH AJY26GALH AJY26GALH AJYA72GALH AJY342GALHH AJY26GALH AJY26GALH AJYA90GALH AJY360GALHH AJY44GALH AJY26GALH AJYA90GALH AJY378GALHH AJY26GALH AJY26GALH AJY26GALH AJY396GALHH AJY44GALH AJY26GALH AJY26GALH Power source Capacity Input power EER COP Air flow rate Sound pressure level* 2 Maximum external static pressure Compressor motor output Heat exchanger fin Dimensions Weight Refrigerant Connection pipe diameter Operation range Height Width Depth Pa W/W m 3 /h db (A) kg Type (Global Warming Potential) Charge kg Liquid Discharge Gas Suction Gas C / , to to 2 0 to ,000+, , to to 2 0 to 2 3phase 4 wire, 400 V, 50Hz , to to 2 0 to , to to 2 0 to , to to 2 0 to , to to 2 0 to ,000+, , to to 2 0 to ,000+, , to to 2 0 to 2 3phase 4 wire, 400 V, 50Hz ,000 2+, , to to 2 0 to ,000 2+, , to to 2 0 to ,000 2+, , to to 2 0 to , , to to 2 0 to , , to to 2 0 to 2 Note : Specifications are based on the following conditions. : Indoor temperature of 27 CDB / 9 CWB, and outdoor temperature of 35 CDB / 24 CWB. : Indoor temperature of 20 CDB / (5 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. * Minimum connectable indoor unit number is 2. *2 The noise value is the value when measured in an anechoic room. When measured in the actual installed state, surrounding noise and reflections are received and the measured value is usually larger than the indicated value. 40 4

22 Features Efficiency in actual operation Top class high COP is realized for all combinations by our unique heat exchanger structure, high efficient DC twin compressor, and other our own technologies. Smart and cutting edge design Extensive lineup from 8HP to 54HP in 2HP increment Connectable indoor unit capacity ratio up to 50% Space saving combination (COP) * (HP) Energy efficiency (COP) For 24 HP Combination Space saving Energy efficiency combination 3 Excellent energy saving Heat pump inverter type realizes the highly energy saving air conditioning for individual cooling and heating operation by all inverter technology for seasonal efficiency * (HP) COP 7% UP design flexibility for various building air conditioning design flexibly meets the various needs of highrise building air conditioning such as outdoor unit roof top concentrated installation and each floor installation by large capacity combination, sufficient connection capacity, and high static pressure design. Easy installation and maintenance The flexible counication method and piping connections makes installation and maintenance easy even for large systems. Energy saving technology that boosted operation efficiency Powerful large propeller fan By using CFD* technology, a newly designed fan achieves high performance and low noise operation. *. CFD = Computational Fluid Dynamics 3 phase DC fan motor Efficiency is substantially improved by high efficient motor with sophisticated driver control. In addition, low noise is realized by DC fan motor. Subcool heat exchanger Heat Exchange efficiency is achieved by using an internal projection shape double pipe construction. Large Office System configuration example This system is used for mediumsized and large buildings. Connecting each outdoor unit makes it possible to create a highcapacity system. Connection of multiple indoor units using separation tubes and headers. Outdoor unit Sinewave DC inverter control efficiency is realized by adoption of reduced switching loss IPM. efficient & Large capacity ALL DC inverter compressor Large capacity high efficient DC twin rotary compressor with 0.Hz steps compressor speed control 4face heat exchanger Heat exchange efficiency is significantly improved by the introduction of a new 4face heat exchanger that increases effective surface area. Capacity 0.Hz Inverter frequency Separation tube Header Front intake port (corner cut air inhaling structure) Advanced energy saving control Liquid pipe Indoor unit Multiple outdoor operation control This control method operates all compressors at part load and distributes refrigerant to all heat exchangers to improve the overall system efficiency. Heat exchanger refrigerant control The efficiency of the top and bottom heat exchanger in the outdoor unit has been improved by adopting an optimum refrigerant rant path control. Gas pipe Fan efficient refrigerant flow control Large intake airflow Larger refrigerant flow Indoor unit Compressor Load level efficient operation Inefficient operation Small intake airflow Heat exchanger Outdoor unit EEV Heat exchanger Distributor 42 43

23 Outdoor units lineup Combinations other than the followings are not recoended. Space saving combination 22.4 (8HP) 28.0 (0HP) 33.5 (2HP) 40.0 (4HP) 45.0 (6HP) Dimensions 8,0HP : AJY072LALBH / AJY090LALBH (Unit : ) 690 (Bolt pitch) 5 (Bolt pitch) 7 (Hole) AJY072LALBH UNIT : AJY072LALBH AJY090LALBH UNIT : AJY090LALBH AJY08LALBH UNIT : AJY08LALBH AJY26LALBH UNIT : AJY26LALBH 50.0 (8HP) 56.0 (20HP) 62.4 (22HP) 68.0 (24HP) 73.0 (26HP) AJY44LALBH UNIT : AJY44LALBH 732 (Bolt pitch) 9 AJY62LALBH UNIT : AJY62LALBH AJYLALBH UNIT : AJY090/090LALBH AJY98LALBH UNIT : AJY26/072LALBH AJY26LALBH UNIT : AJY26/090LALBH AJY234LALBH UNIT : AJY44/090LALBH 78.0 (28HP) 85.0 (HP) 90.0 (32HP) 95.0 (34HP) 00.0 (36HP) AJY252LALBH UNIT : AJY62/090LALBH AJY270LALBH UNIT : AJY44/26LALBH AJY288LALBH UNIT : AJY44/44LALBH AJY6LALBH UNIT : AJY62/44LALBH AJY324LALBH UNIT : AJY62/62LALBH 06.0 (38HP) 3.0 (40HP) 8.0 (42HP) 23.0 (44HP) 28.0 (46HP) B A C AJY342LALBH UNIT : AJY62/090/090LALBH AJY360LALBH UNIT : AJY44/26/090LALBH AJY378LALBH UNIT : AJY44/44/090LALBH AJY396LALBH UNIT : AJY62/44/090LALBH AJY44LALBH UNIT : AJY62/62/090LALBH 2,4,6,8HP : AJY08LALBH / AJY26LALBH / AJY44LALBH / AJY62LALBH (Unit : ) 35.0 (48HP) 40.0 (50HP) 45.0 (52HP) 50.0 (54HP) 000 (Bolt pitch) 840 (Bolt pitch) 7 (Hole) AJY432LALBH UNIT : AJY44/44/44LALBH AJY450LALBH UNIT : AJY62/44/44LALBH AJY468LALBH UNIT : AJY62/62/44LALBH AJY486LALBH UNIT : AJY62/62/62LALBH 732 (Bolt pitch) Energy efficiency combination (6HP) 50.4 (8HP) 55.9 (20HP) 67.2 (24HP) 72.8 (26HP) 690 AJY44LALBHH UNIT : AJY072/072LALBH AJY62LALBHH UNIT : AJY090/072LALBH AJYLALBH UNIT : AJY08/072LALBH AJY26LALBHH UNIT : AJY072/072/072LALBH AJY234LALBHH UNIT : AJY090/072/072LALBH 78.3 (28HP) 84.8 (HP) 89.4 (32HP) 95.9 (34HP) 00.5 (36HP) B A C AJY252LALBHH UNIT : AJY08/072/072LALBH AJY270LALBHH UNIT : AJY26/072/072LALBH AJY288LALBHH UNIT : AJY08/08/072LALBH AJY6LALBHH UNIT : AJY26/08/072LALBH AJY324LALBHH UNIT : AJY08/08/08LALBH 07.0 (38HP) 3.5 (40HP) 20.0 (42HP) 25.0 (44HP).0 (46HP) AJY342LALBHH UNIT : AJY26/08/08LALBH AJY360LALBHH UNIT : AJY26/26/08LALBH AJY378LALBHH UNIT : AJY26/26/26LALBH AJY396LALBHH UNIT : AJY44/26/08LALBH AJY44LALBHH UNIT : AJY44/44/26LALBH A Front side knockout position 73 Ø Ø 43.7 Ø 50 Ø 22.2 Power supply cable port Power supply cable port Power supply cable port Transmission cable port Ø 22.2 Transmission cable port Pipe port B Left side knockout position Ø 50 Power supply cable port Ø 22.2 Transmission cable port Ø 34.5 Power supply cable port Ø 43.7 Power supply cable port Ø 22.2 Transmission cable port C Bottom side knockout position Pipe port Top view

24 Outdoor units specifications Space Saving Combination Rating Capacity range HP Unit Unit 2 Unit 3 Maximum Connectable Indoor Unit* Indoor unit connectable capacity AJY072LALBH AJY072LALBH AJY090LALBH AJY090LALBH AJY08LALBH AJY08LALBH AJY26LALBH AJY26LALBH AJY44LALBH AJY44LALBH AJY62LALBH AJYLALBH AJY62LALBH AJY090LALBH AJY090LALBH AJY98LALBH AJY26LALBH AJY234LALBH AJY252LALBH AJY26LALBH AJY26LALBH AJY44LALBH AJY62LALBH AJY072LALBH AJY090LALBH AJY090ALBH AJY090LALBH AJY270LALBH AJY44LALBH AJY26LALBH AJY288LALBH AJY44LALBH AJY44LALBH AJY6LALBH AJY62LALBH AJY44LALBH AJY324LALBH AJY62LALBH AJY62LALBH AJY342LALBH AJY62LALBH AJY090LALBH AJY090LALBH AJY360LALBH AJY44LALBH AJY26LALBH AJY090LALBH AJY378LALBH AJY44LALBH AJY44LALBH AJY090LALBH AJY396LALBH AJY62LALBH AJY44LALBH AJY090LALBH AJY44LALBH AJY62LALBH AJY62LALBH AJY090LALBH AJY432LALBH AJY44LALBH AJY44LALBH AJY44LALBH AJY450LALBH AJY62LALBH AJY44LALBH AJY44LALBH AJY468LALBH AJY62LALBH AJY62LALBH AJY44LALBH AJY486LALBH AJY62LALBH AJY62LALBH AJY62LALBH Power source Capacity Input power EER COP Air flow rate Sound pressure level* 2 Maximum external static pressure Compressor motor output Heat exchanger fin Dimensions Weight Refrigerant Connection pipe diameter Operation range Pa Height Width Depth W/W m 3 /h db (A) kg Type (Global Warming Potential) Charge kg Liquid Gas C , to to , to to , , to to , , to to , , to to 2 3phase 4 wire, 400 V, 50Hz , , to to , to to ,000+, , to to ,000+, , to to ,000+, , to to ,700+, , to to ,700+3, , to to , , to to , , to to , , to to ,700+, , to to ,700+3,000+, , to to 2 3phase 4 wire, 400 V, 50Hz ,700 2+, , to to ,700 2+, , to to ,700 2+, , to to , , to to , , to to , , to to , , to to 2 Energy Efficiency Combination Rating Capacity range HP Unit Unit 2 Unit 3 Maximum Connectable Indoor Unit* Indoor unit connectable capacity AJY44LALBHH AJY072LALBH AJY072LALBH AJY62LALBHH AJY090LALBH AJY072LALBH AJYLALBHH AJY08LALBH AJY072LALBH AJY26LALBHH AJY072LALBH AJY072LALBH AJY072LALBH AJY234LALBHH AJY090LALBH AJY072LALBH AJY072LALBH AJY252LALBHH AJY08LALBH AJY072LALBH AJY072LALBH AJY270LALBHH AJY26LALBH AJY072LALBH AJY072LALBH AJY288LALBHH AJY08LALBH AJY08LALBH AJY072LALBH AJY6LALBHH AJY26LALBH AJY08LALBH AJY072LALBH AJY324LALBHH AJY08LALBH AJY08LALBH AJY08LALBH AJY342LALBHH AJY26LALBH AJY08LALBH AJY08LALBH AJY360LALBHH AJY26LALBH AJY26LALBH AJY08LALBH AJY378LALBHH AJY26LALBH AJY26LALBH AJY26LALBH AJY396LALBHH AJY44LALBH AJY26LALBH AJY26LALBH AJY396LALBHH AJY44LALBH AJY26LALBH AJY26LALBH Power source Capacity Input power EER COP Air flow rate Sound pressure level* 2 Maximum external static pressure Compressor motor output Heat exchanger fin Dimensions Weight Refrigerant Connection pipe diameter Operation range Height Width Depth Pa W/W m 3 /h db (A) kg Type (Global Warming Potential) Charge kg Liquid Gas C , to to , to to ,000+, , to to 2 3phase 4 wire, 400 V, 50Hz , to to , to to ,000+, , to to ,000+, , to to ,000 2+, , to to ,000 2+, , to to , , to to 2 3phase 4 wire, 400 V, 50Hz , , to to , , to to , , to to ,700+3, , to to , , , to to 2 Note : Specifications are based on the following conditions. : Indoor temperature of 27 CDB / 9 CWB, and outdoor temperature of 35 CDB / 24 CWB. : Indoor temperature of 20 CDB / (5 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. * Minimum connectable indoor unit number is 2. However ARXC72 and ARXC90 can be used signal connection. *2 The noise value is the value when measured in an anechoic room. When measured in the actual installed state, surrounding noise and reflections are received and the measured value is usually larger than the indicated value

25 Features Efficiency in actual operation Top class high COP is realized for all combinations by our unique heat exchanger structure, high efficient DC twin compressor, and other our own technologies. Smart and cutting edge design Extensive lineup from 8HP to 48HP in 2HP increment Connectable indoor unit capacity ratio up to 50% Space saving combination (COP) * (HP) (COP) 5 For 24 HP Combination Space saving Energy efficiency Energy efficiency Excellent energy savings Heat pump type inverter control is used to achieve economic cooling and heating operation for individual air conditioning to entire air conditioning. combination * (HP) COP 8% UP design flexibility for various building air conditioning The high static pressure design flexibly meets the needs of high rise buildings including easy installation on each floor. Easy installation and maintenance The flexible counication method and piping connections makes installation and maintenance easy even for large systems. Energy saving technology that boosted operation efficiency Powerful large propeller fan By using CFD * technology, A newly designed fan achieves high performance and low noise operation. *. CFD = Computational Fluid Dynamics DC fan motor Power consumption has been reduced by 25% compared to previous models by using a compact and high performance DC fan motor. Large Office System configuration example This system is used for mediumsized and large buildings. Connecting each outdoor unit makes it possible to create a highcapacity system. Connection of multiple indoor units using separation tubes and headers. Subcool heat exchanger Heat Exchange efficiency is achieved by using an internal projection shape double pipe construction. Sinewave DC inverter control efficiency operation is realized by using a sine wave DC inverter control. Outdoor unit Separation tube Header DC twin rotary compressor Significantly greater efficiency is realized by use of a large capacity DC twin rotary compressor with substantially increased refrigerant intake and compression efficiency. Liquid pipe Gas pipe Indoor unit 4face heat exchanger Heat exchange efficiency is significantly improved by the introduction of a new 4face heat exchanger that increases effective surface area. Indoor unit Front intake port (Corner cut air inhaling structure) In multiple outdoor unit installations, the unique front intake design improves airflow into the Heat Exchanger

26 Outdoor units lineup Combinations other than the followings are not recoended. Space saving combination 22.4 (8HP) 28.0 (0HP) 33.5 (2HP) 40.0 (4HP) 45.0 (6HP) Dimensions 8,0,2HP : AJYA72LALH / AJYA90LALH / AJY08LALH 690 (Bolt pitch) (Unit : ) 5 (Bolt pitch) 7 (Hole) AJYA72LALH UNIT : AJYA72LALH AJYA90LALH UNIT : AJYA90LALH AJY08LALH UNIT : AJY08LALH AJY26LALH UNIT : AJY26LALH 50.4 (8HP) 55.9 (20HP) 6.5 (22HP) 67.0 (24HP) 73.5 (26HP) AJY44LALH UNIT : AJY44LALH 732 (Bolt pitch) 9 AJY62LALH UNIT : AJYA90/A72LALH AJYLALH UNIT : AJY08/A72LALH AJY98LALH UNIT : AJY08/A90LALH AJY26LALH UNIT : AJY08/08LALH AJY234LALH UNIT : AJY26/08LALH 78.5 (28HP) 85.0 (HP) 90.0 (32HP) 95.0 (34HP) 00.5 (36HP) AJY252LALH UNIT : AJY44/08LALH AJY270LALH UNIT : AJY44/26LALH AJY288LALH UNIT :AJY44/44LALH AJY6LALH UNIT : AJY08/08/A90LALH AJY324LALH UNIT : AJY08/08/08LALH 07.0 (38HP) 2.0 (40HP) 8.5 (42HP) 23.5 (44HP).0 (46HP) B A C AJY342LALH UNIT : AJY26/08/08LALH AJY360LALH UNIT : AJY44/08/08LALH AJY378LALH UNIT : AJY44/26/08LALH AJY396LALH UNIT : AJY44/44/08LALH AJY44LALH UNIT : AJY44/44/26LALH 4,6HP : AJY26LALH / AJY44LALH (Unit : ) 35.0 (48HP) 000 (Bolt pitch) 840 (Bolt pitch) 7 (Hole) AJY432LALH UNIT : AJY44/44/44LALH 732 (Bolt pitch) Energy efficiency combination (6HP) 62.4 (22HP) 67.2 (24HP) 72.8 (26HP) 78.3 (28HP) 690 AJY44LALHH UNIT : AJYA72/A72LALH AJY98LALHH UNIT : AJY26/A72LALH AJY26LALHH UNIT : AJYA72/A72/A72LALH AJY234LALHH UNIT : AJYA90/A72/A72LALH AJY252LALHH UNIT : AJY08/A72/A72LALH 84.8 (HP) 89.8 (32HP) 95.9 (34HP) 02.4 (36HP) 3.5 (40HP) B A C AJY270LALHH UNIT : AJY26/A72/A72LALH 20.0 (42HP) AJY378LALHH UNIT : AJY26/26/26LALH AJY288LALHH UNIT : AJY08/08/A72LALH 25.0 (44HP) AJY396LALHH UNIT : AJY44/26/26LALH AJY6LALHH UNIT : AJY26/08/A72LALH AJY324LALHH UNIT : AJY26/26/A72LALH AJY360LALHH UNIT : AJY26/26/08LALH A Front side knockout position 73 Ø Ø 43.7 Ø 50 Ø 22.2 Power supply cable port Power supply cable port Power supply cable port Transmission cable port Ø 22.2 Transmission cable port Pipe port B Left side knockout position Ø 50 Power supply cable port Ø 22.2 Transmission cable port Ø 34.5 Power supply cable port Ø 43.7 Power supply cable port Ø 22.2 Transmission cable port C Bottom side knockout position Pipe port Top view

27 Outdoor units specifications Space Saving Combination Rating Capacity range HP Power source Capacity Unit Unit 2 Unit 3 Maximum Connectable Indoor Unit* Indoor unit connectable capacity Input power EER COP Air flow rate Sound pressure level* 2 Maximum external static pressure Compressor motor output Heat exchanger fin Dimensions Weight Refrigerant Connection pipe diameter Operation range Pa Height Width Depth W/W m 3 /h db (A) kg Type (Global Warming Potential) Charge kg Liquid Gas C AJYA72LALH AJYA90LALH AJY08LALH AJY26LALH AJY44LALH AJY62LALH AJYA72LALH AJYA90LALH AJY08LALH AJY26LALH AJY44LALH AJYA90LALH AJYA72LALH , to to , to to , to to , , to to phase 4 wire, 400 V, 50Hz , , to to ,00 x x 2 9 x x to to 2 AJYLALH AJY08LALH AJYA72LALH ,00 x x x to to 2 AJY98LALH AJY08LALH AJYA90LALH ,00 x x x to to 2 AJY26LALH AJY08LALH AJY08LALH ,00 x x x 2 9 x x to to 2 AJY234LALH AJY26LALH AJY08LALH AJY252LALH AJY44LALH AJY08LALH AJY270LALH AJY44LALH AJY26LALH AJY288LALH AJY44LALH AJY44LALH AJY6LALH AJY08LALH AJY08LALH AJYA90LALH AJY324LALH AJY08LALH AJY08LALH AJY08LALH AJY342LALH AJY26LALH AJY08LALH AJY08LALH AJY360LALH AJY44LALH AJY08LALH AJY08LALH AJY378LALH AJY44LALH AJY26LALH AJY08LALH AJY396LALH AJY44LALH AJY44LALH AJY08LALH AJY44LALH AJY44LALH AJY44LALH AJY26LALH AJY432LALH AJY44LALH AJY44LALH AJY44LALH ,000 +, x x 2 9 +, x to to ,000 +, x x 2 9 +, x to to ,000 x x x 2,240 x x 2 5 to to ,000 x x x 2,240 x x 2 5 to to ,00 x x x 2 9 x x to to ,00 x x x 3 9 x x to to phase 4 wire, 400 V, 50Hz ,000 +, x x 3 9 x 2 +, x to to ,000 +, x x 3 9 x 2 +, x to to , , x x 3 9 +,240 x x to to , , x x 3 9 +,240 x x to to ,000 x x x 3,240 x x to to ,000 x x x 3,240 x x to to 2 Energy Efficiency Combination Rating Capacity range HP Unit Unit 2 Unit 3 Maximum Connectable Indoor Unit* Indoor unit connectable capacity AJY44LALHH AJYA72LALH AJYA72LALH AJY98LALHH AJY26LALH AJYA72LALH AJY26LALHH AJYA72LALH AJYA72LALH AJYA72LALH AJY234LALHH AJYA90LALH AJYA72LALH AJYA72LALH AJY252LALHH AJY08LALH AJYA72LALH AJYA72LALH AJY270LALHH AJY26LALH AJYA72LALH AJYA72LALH AJY288LALHH AJY08LALH AJY08LALH AJYA72LALH AJY6LALHH AJY26LALH AJY08LALH AJYA72LALH AJY324LALHH AJY26LALH AJY26LALH AJYA72LALH AJY360LALHH AJY26LALH AJY26LALH AJY08LALH AJY378LALHH AJY26LALH AJY26LALH AJY26LALH AJY396LALHH AJY44LALH AJY26LALH AJY26LALH Power source Capacity Input power EER COP Air flow rate Sound pressure level* 2 Maximum external static pressure Compressor motor output Heat exchanger fin Dimensions Weight Refrigerant Connection pipe diameter Operation range Height Width Depth Pa W/W m 3 /h db (A) kg Type (Global Warming Potential) Charge kg Liquid Gas C ,00 x x 2 9 x x to to ,000 +, x , to to 2 3phase 4 wire, 400 V, 50Hz ,00 x x 3 9 x x to to ,00 x x 3 9 x x to to ,00 x x x x to to ,000 +,000 x x x 2 +, x 2 5 to to ,00 x to to ,000 +,00 x x x 2 9 x 2 +, x to to 2 3phase 4 wire, 400 V, 50Hz ,000 x 2 +, x x 2 9 +,240 x x to to ,000 x 2 +, x x 3 9 +,240 x x to to ,000 x x x 3,240 x x to to ,000 x x x 3,240 x x to to 2 Note : Specifications are based on the following conditions. : Indoor temperature of 27 CDB / 9 CWB, and outdoor temperature of 35 CDB / 24 CWB. : Indoor temperature of 20 CDB / (5 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. * Minimum connectable indoor unit number is 2. However ARXC72 and ARXC90 can be used signal connection. *2 The noise value is the value when measured in an anechoic room. When measured in the actual installed state, surrounding noise and reflections are received and the measured value is usually larger than the indicated value

28 Features Efficiency in actual operation N E W Top class high COP is achieved for all models by large heat exchanger, high efficient DC twin compressor, and our own technologies. EER / COP EER / COP Fujitsu General provides air conditioning systems for a wide range of applications from small office buildings and stores to large houses. [3phase] [Single phase] HP class 8% UP % UP Energy Efficiency 4HP 5HP 6HP 4HP 5HP 6HP JII JIII JII JIII Heat pump inverter control is used to achieve an efficient cooling and heating operation in any indoor unit combination. Advanced high efficiency technology Flexible systems for small and mediumsize buildings air conditioning Space saving design and long piping design allow for flexible installation on the roofs or balconies of smalland mediumsize buildings. Multiple indoor units of various capacities and types can be connected. Large propeller fan performance and low noise realized by large propeller and optimization of angle. DC inverter control Efficiency is improved by mounting of new active filter module. DC fan motor Miniaturized, low noise, high efficiency, multistage DC fan motor is mounted. Small Office System configuration example This system is used for small and mediumsized buildings. refrigerant system is used for each outdoor unit. Connection of multiple indoor units using separation tubes and headers. Subcool heat exchanger performance is improved by mounting of dual tube heat exchanger. Outdoor unit Separation tube Header Large heat exchanger Heat exchange performance is substantially improved by mounting of 3row large heat exchanger. Pressure effect efficiency compressor motor DC twin rotary compressor Efficiency in all load regions is good. Especially good performance from low to medium at normal operation. performance improved Enthalpy Liquid pipe Indoor unit Optimized refrigerant flow design Gas pipe ly accurate parts Compressor efficiency DC Twin Rotary compressor Indoor unit Compressor capacity 54 55

29 Features Long piping capability Our advanced refrigerant control technology allows us to achieve a total refrigerant piping length of m. This opens up new possibilities in system design. Total pipe length m max. Specifications Rating Capacity range Maximum Connectable Indoor Unit HP 4 AJY040LBLAH 9 5 AJY045LBLAH 0 6 AJY054LBLAH 3 4 AJY040LELAH 9 5 AJY045LELAH 0 6 AJY054LELAH 3 Actual piping length 20m max. Height difference between outdoor and indoor units 50m max. For the outdoor unit installed below the indoor units: 40 m max. Power source Capacity Input power EER COP Air flow rate Sound pressure level Heat exchanger fin Net Dimensions Weight Refrigerant Connection pipe diameter Total pipe length Max. Height difference Operation range Height Width W/W m 3 /h db (A) Depth kg Type (Global Warming Potential) Charge kg Liquid Gas m C , , Singlephase, ~2V, 50Hz ,400 6, ,334, /40 (Outdoor unit: Upper/Lower) 5 to 46 5 to 46 5 to to 2 20 to 2 20 to , , phase, ~400V, 50Hz , , , , to to 2 50/40 (Outdoor unit: Upper/Lower) 5 to to 2 5 to to 2 Piping length from first separation tube to the farthest indoor unit 40m max. Height difference between indoor and indoor units 5m max. Note : Specifications are based on the following conditions. : Indoor temperature of 27 CDB / 9 CWB, and outdoor temperature of 35 CDB / 24 CWB. : Indoor temperature of 20 CDB / (5 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. The protective function may work when using it outside the operation range. Dimensions Model : AJY040LBLAH / AJY045LBLAH / AJY054LBLAH / AJY040LELAH / AJY045LELAH / AJY054LELAH (Unit : ) Nonstop oil recovery operation (Liquid) 5(Gas) (40) 40 A comfortable room condition is maintained during oil recovery mode because the product continues to operate without stopping the cooling or heating operation. Previous model JIII series ( operation) Terminal blocks (Transmission) Operation stopped at oil recovery Nonstop oil recovery operation ON OFF Time ON Time 334 Terminal blocks (Power) 3Way valve (Liquid) Easier Installation Connection check function : Possible to confirm whether wiring connection and address setting are correct by a quick check run function Ø28 (Cable port) 89 3Way valve (Gas) Ø28 (Cable port) Pipe port 279 (Liquid valve) 297 (Gas valve) Ø28 (Cable port) 2 55 Ø28 (Cable port) Pipe port 2 50 Ø28 (Cable port) Ø28 (Cable port) Pipe port A 5 4 Detail A Display connected indoor unit numbers 50 Duplicately set address number of indoor unit can be displayed Pipe & cable port 56 57

30 Features It Can be Easily Carried and Installed Obscure Place Small and light weight outdoor unit This model is much more compact than conventional 6HP comparable outdoor units. Even when installed on the balcony it fits within the height of the fence. The compact size with a height of less than m allows it to be installed under windows and in tight spaces Fujitsu General provides air conditioning systems for a wide range of applications from small office buildings and stores to large houses. Current model / 6 HP class Height:334 Weight:7 kg Model / 6 HP class Space saving and low sound level design Economical individual air conditioning is realized by ALLDC technology, large capacity DC twin rotary compressor, and 3row heat exchanger though the size is compact. Height difference % Light weight 87 kg Low sound level design Significantly low sound level is improved by using DC twin rotary compressor, inverter technology, and advanced airflow structure design. db(a) Flexible systems for homes, shops, smallsize buildingss air conditioning Due to compact size design and flexible piping design, JIIS series can be installed easily at the place where the installation space is limited such as homes, shops, and small offices. Multiple indoor units of various capacities and types can be connected. Advanced high efficiency technology 4 HP 5 HP 6 HP 6 HP Previous model Large propeller fan performance and low noise realized by large propeller and optimization of angle. DC inverter control Efficiency is improved by mounting of new active filter module. Large Homes System configuration example Low noise rubber Outdoor unit Separation tube Header DC fan motor Miniaturized, low noise, high efficiency, multistage DC fan motor is mounted. efficiency compressor motor Optimized refrigerant flow design ly accurate parts Liquid pipe Gas pipe Indoor unit Indoor unit Large heat exchanger Heat exchange performance is substantially improved by mounting of 3row large heat exchanger. heat transfer copper tube (Improved lead angle) Smooth airflow grille This grille was aerodynamically designed for good efficiency with little blow loss. Compact and high performance DC twin rotary compressor Efficiency in all load regions is good. Especially good performance from low to medium at normal operation. Compressor efficiency Compressor capacity 00% 58 59

31 Features Long Piping Length Our advanced refrigerant control technology allows us to achieve a total refrigerant piping length of m. This opens up new possibilities in system design. Total pipe length m max. Specifications Rating capacity range Maximum connectable indoor unit HP 4 AJY040LCLAH 7 5 AJY045LCLAH 8 6 AJY054LCLAH 8 Actual piping length 50m max. Height difference between outdoor and indoor units m max. Power source Capacity Input power EER COP V/Ø/Hz W/W Airflow rate m 3 /h Sound db Pressure level (A) Heat exchanger fin Height Dimensions Width Depth Weight kg Refrigerant Type (Global Warming Potential) Charge kg Connection Liquid Pipe diameter Gas Total pipe length Max. Height difference Operation Range m C Singlephase, ~2V, 50Hz , to to 2 Singlephase, ~2V, 50Hz , to to 2 Singlephase, ~2V, 50Hz , to to 2 Piping length from first separation tube to the farthest indoor unit 40m max. Height difference between indoor and indoor units 5m max. Note : Specifications are based on the following conditions. : Indoor temperature of 27 CDB / 9 CWB, and outdoor temperature of 35 CDB / 24 CWB. : Indoor temperature of 20 CDB / (5 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. The protective function may work when using it outside the operation range. Dimensions Model : AJY040LCLAH / AJY045LCLAH / AJY054LCLAH (Unit : ) Nonstop oil recovery operation Previous model JIIS series ( operation) Top view A comfortable room condition is maintained during oil recovery mode because the product continues to operate without stopping the cooling or heating operation. * Operation stopped at oil recovery Nonstop oil recovery operation ON ON OFF Time Time Easier Installation Connection check function : Possible to confirm whether wiring connection and address setting are correct by a quick check run function. Front view Side view Rear view Display connected indoor unit numbers Duplicately set address number of indoor unit can be displayed Bottom view Detail A 60 6

32 The AIRSTAGE indoor units were developed to be highly efficient, compact, low noise and to have user friendly operation. With a variety of indoor units and capacities available, Fujitsu General has an indoor unit to match any requirement which is easy to install and maintain. Further, a variety of options are available to achieve an air conditioning environment that is more desirable from the user s perspective. Compact Cassette Cassette Mini Duct Slim Duct / Slim Concealed Floor Medium Static Pressure Duct Static Pressure Duct Large Airflow Duct Floor / Ceiling Ceiling Wall mounted (EEV Internal / external ) 62 63

33 Indoor units Improvement of the airflow distribution lift drain pump Models AUXB04GALH AUXB07GALH AUXB09GALH AUXB2GALH AUXB4GALH AUXB8GALH AUXB24GALH Compact size panel design that fits standard ceiling panel (600x600) 2stage turbo fan Quiet quality A B C D 2 Grille cover Maintenance of fan motor and fan Maintenance of the fan motor and fan can be done easily after taking off the panel as the bell mouth of the fan can be removed easily. A : Fan motor C : Bellmouth B : 2stage turbo fan D : Panel 3 Model code Ceiling panel ceiling mode Standard mode Max. Max. 700 The compact cassette can be installed up to a height of 3.0m (2/4/8/24). The maximum height from floor to ceiling (m) ceiling mode efficiency design by 2 stage structure An evenly spread air distribution across the heat exchanger is possible due to the new 2 stage turbo fan which produces two separate airflow streams. stage + = 2stage 2stage turbo fan Heat exchange efficiency 20%UP Previous turbo fan In the case of a previous fan, the air outlet range was narrow as the airflow moved to the motor side which meant the velocity of air passing through the heat exchanger was uneven. Wind velocity Fast Slow Optimization of wing form (laminar wing type) and wing number (7 blades each) Designed by CFDanalysis (fluid) simulations Adoption of laminar wing Quiet Spin direction Airflow direction Laminar wing Airflow runs through smoothly along the laminar wing Quiet No airflow separation 2 Air filter : standard equipment 3 Adaptation of transparent drainage parts During installation, maintenance and operation, the drain pump and kit can be checked easily. Compact design Worlds first 24,000Btu model in the compact cassette category (Easy installation by taking off ceiling panel of 600 x 600 size) Optional parts Air Outlet Shutter Plate : UTRYDZB Insulation Kit for Humidity : UTZKXGC Fresh Air Intake Kit : UTZVXAA Specifications Dimensions (Unit : ) AUXB04GALH AUXB07GALH AUXB09GALH AUXB2GALH AUXB4GALH AUXB8GALH AUXB24GALH Models: AUXB04 / AUXB07 / AUXB09 / AUXB2 / AUXB4 / AUXB8 / AUXB24 Power source Capacity V ~, 50Hz Hanging bolt position Input power Airflow rate Sound pressure level Med Low W m 3 /h /450* 0/350* , : Indoor unit Hanging bolt position 5 to 660 Ceiling openings Med db(a) 28/* Dimensions (H x W x D) Low 2/25* x 570 x IR receiver 5 Drain hose Weight kg 5 7 Connection pipe diameter Cassette Grille Liquid (Flare) Gas (Flare) Drain Dimensions (H x W x D) ø6.35 ø2.70 ø25 (I.D) ; ø32 (O.D.) UTGUFYCW 50 x 700 x 700 ø9.52 ø Weight kg 2.6 Note : Specifications are based on the following conditions. : Indoor temperature of 27 CDB / 9 CWB, and outdoor temperature of 35 CDB / 24 CWB. : Indoor temperature of 20 CDB / (5 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 2 [V]. *: This value is under cooling operation. 4 Ceiling 4 9 Gas pipe Control Box Liquid pipe

34 Indoor units Models (Slim type) AUXD8GALH AUXD24GALH Powerful, wide airflow and quiet operation efficiency turbo fan with 3dimensional blade Models (Large type) AUXA8GALH AUXA24GALH AUXAGALH AUXA34GALH AUXA36GALH AUXA45GALH AUXA54GALH Improvement of the airflow distribution The louvre design distributes air leaving a space between the chassis and the ceiling allowing far and wide air flow distribution. Rear part Front part Round louvre Ceiling Adjustment of hanger position is possible after installation Detachable Grille corner Bottom view Much less temperature irregularity happens by spreading airflow widely lift drain pump Model code Ceiling panel ceiling mode Standard mode Max. 850 This cassette can be installed up to a height of 4.2m (36/45/54). The maximum height from floor to ceiling (m) ceiling mode efficiency airflow distribution has been achieved by the introduction of a 3 dimensional blade which increases the air passing over the heat exchanger dimensional blade Previous turbo fan Air passing through the heat exchanger was uneven and the air would only flow close to the ceiling. 450 Previous blade Adjustment can be done just taking off the corner part One way aperture installation Optional parts Wind velocity Fast Slow Heat exchanger < Motor side > Quiet No airflow separation Heat exchanger < Motor side > Uneven airflow Separation phenomenon of airflow causes noise Parallel apertures IR Receiver Unit : UTYLRHYB Air Outlet Shutter Plate : UTRYDZK Panel Spacer : UTGBKXAW Insulation Kit for Humidity : UTZKXRA Wide Panel : UTGAKXAW Fresh Air Intake Kit : UTZVXRA : Spin direction : Airflow direction : Turbulent flow noise Specifications Dimensions (Unit : ) ( ) : AUXD8 / AUXD24 Power source Capacity Input power Airflow rate W AUXD8GALH ,50 AUXD24GALH ,2 AUXA8GALH ,420 AUXA24GALH ,420 AUXAGALH 2V ~, 50Hz ,600 AUXA34GALH ,750 AUXA36GALH.2 2.5,0 AUXA45GALH ,900 AUXA54GALH ,000 Models: AUXD8 / AUXD24 (Slim type) AUXA8 / AUXA24 / AUXA / AUXA34 / AUXA36 / AUXA45 / AUXA54 (Large type) IR receiver (Option) Hanging bolt position Sound pressure level Dimensions (H x W x D) Med Low Med Low m 3 /h db(a) 940, x 840 x 840,2,2,00/,000*,00/,000* /3* 33/3*,0, ,0, x 840 x 840,0, ,370, ,370, : Indoor unit Hanging bolt position 860 to 90 Ceiling opening Weight Connection pipe diameter Liquid (Flare) Gas (Flare) kg 22 ø5.88 ø ø (Control) Box 358 Drain hose Cassette Grille Drain Dimensions (H x W x D) Weight kg ø25 (I.D.) ; ø32 (O.D.) UTGUGYAW 50 x 950 x (256) Note : Specifications are based on the following conditions. : Indoor temperature of 27 CDB / 9 CWB, and outdoor temperature of 35 CDB / 24 CWB. : Indoor temperature of 20 CDB / (5 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 2 [V]. *: This value is cooling operation / heating operation. 42 Ceiling 42 0 Liquid pipe Wire hole Gas pipe

35 Indoor units performance & Low noise design 6speed control* Models (With drain pump) ARXK07GCLH ARXK09GCLH ARXK2GCLH ARXK4GCLH ARXK8GCLH ARXK24GCLH N E W N E W N E W N E W N E W N E W ARXK07GCLH ARXK2GCLH ARXK09GCLH ARXK4GCLH ARXK8GCLH Drastic low noise operation and high performance can be achieved by Vshaped heat exchanger structure and optimum airflow design. Fan casing Multistep airflow speed control allows this model to install in a quiet location. 6Step Speed MeHi Med LoHi Low Low noise 2dB(A) at 07/09 models Compact & Slim Duct indoor unit for creating comfortable living space ARXK24GCLH V shaped heat exchanger Optimum airflow path Quiet * Compatible Remote Controller is as follows: UTYRNRYZ/UTYRLRY/UTYDCGY/UTYDTGYZ/UTYALGX/UTYAPGX Optimum design in harmony with interior decoration Thin and shortdepth body makes the clipped ceiling design simple. Easy drain design even at narrow ceiling Drainage to the distant drain port is possible Drain pump builtin Drain design is easy even at narrow ceiling. Optional parts Remote Sensor Unit : IR Receiver Unit : Auto Louver Grille Kit : UTYXSZX UTBYWC UTDGXTAW (for ARXK07/09/2/4GCLH) UTDGXTBW (for ARXK8GCLH) UTDGXTCW (for ARXK24GCLH) Specifications Dimensions (Unit : ) ARXK07GCLH ARXK09GCLH ARXK2GCLH ARXK4GCLH ARXK8GCLH ARXK24GCLH Models: ARXK07 / ARXK09 / ARXK2 / ARXK4 / ARXK8 / ARXK24 Power source Capacity Input power MeHi Med Airflow rate LoHi Low Quiet Static pressure range Standard static pressure MeHi Med Sound pressure level LoHi Low Quiet Dimensions (H x W x D) Weight Connection Liquid (Flare) pipe diameter Gas (Flare) Drain W m 3 /h Pa db(a) kg to V ~, 50Hz to to to x 700 x ø6.35 ø2.70 ø25 (I.D.) ; ø32 (O.D.) ,60 840, to 50 0 to x 900 x x,00 x ø9.52 ø5.88 View A (Drain hose) Rear view A B C Top view D E F Front view Drain port Side view 450 Refrigerant pipe flare connection (Liquid) 2 Refrigerant pipe flare connection (Gas) 3 Drain hose connection A B C D E F ARXK074 P00 6= ARXK8 P00 8= ARXK24 P00 0= Note : Specifications are based on the following conditions. : Indoor temperature of 27 CDB / 9 CWB, and outdoor temperature of 35 CDB / 24 CWB. : Indoor temperature of 20 CDB / (5 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 2 [V]. 69

36 Indoor units lift drain pump Auto Louver Grille Kit (Option) Models (With drain pump) ARXD04GALH ARXD07GALH ARXD09GALH ARXD2GALH ARXD4GALH ARXD8GALH ARXD24GALH Slim design and wide range of static pressure for flexible installation. ARXD04GALH ARXD2GALH ARXD07GALH ARXD4GALH ARXD09GALH Slim Concealed Floor ARXD8GALH ARXD24GALH Drain hose is standard accessory Selectable with a wide range of static pressure By using DC fan motor, it is possible to change of static pressure range 0 to 90Pa. The change of static pressure range is possible by remote controller. Max. 850 Static pressure range 0 to 90 Pa *24 model is 0 to 50Pa Simple flat Auto Louver will provide comfort airflow and harmonize with luxury interior. Slim Duct Wired Remote Controller Auto Louver Grille Wireles Remote Controller Filter (Accessory) ARXD04 / 07 / 09 / 2 / 4 / 8 Filter (2pcs.) ARXD24 Filter (3pcs.) Flexible installation Ceiling concealed Slim design Airintake This model is slim design, it can install at the place where a ceiling is narrow. Drain port Air intake direction can be selected to match the installation site. Floor concealed Optional parts Drain pump Height 98 Drain pump builtin Bottom side Back side Remote Sensor Unit : UTYXSZX IR Receiver Unit : UTBYWC Auto Louver Grille Kit : UTDGXTAW (for ARXD04/07/09/2/4GALH) UTDGXTBW (for ARXD8GALH) UTDGXTCW (for ARXD24GALH) Specifications Dimensions (Unit : ) Power source Capacity Input power W ARXD04GALH ARXD07GALH ARXD09GALH ARXD2GALH 2V ~, 50Hz ARXD4GALH ARXD8GALH ARXD24GALH Models: ARXD04 / ARXD07 / ARXD09 / ARXD2 / ARXD4 / ARXD8 / ARXD24 *Service accessibility must be allowed for when installing the product. Please consult the installation manual for the necessary service access size G 74 Airflow rate ,3 Static pressure range Standard static pressure Med Low m 3 /h Pa 400/470* 320/440* 0 to to to to to to 90 25,240,00 0 to (Bolt pitch) 48 Sound pressure level Dimensions (H x W x D) Weight Connection pipe diameter Med Low Liquid (Flare) Gas (Flare) Drain db(a) kg Note : Specifications are based on the following conditions. 26 2/25* 20/22* x 700 x ø6.35 ø2.70 ø25 (I.D.) ; ø32 (O.D.) x 900 x x,00 x ø9.52 ø5.88 : Indoor temperature of 27 CDB / 9 CWB, and outdoor temperature of 35 CDB / 24 CWB. : Indoor temperature of 20 CDB / (5 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 2 [V]. *: This value is under cooling operation. F (All surroundings) E D C (Bolt pitch) B A A B C D E F G ARXD044 ARXD8 ARXD P00x6=600 P00x8=0 P00x0=000 8xØ5 22xØ5 26xØ

37 Models ARXA24GBLH ARXAGBLH ARXA36GBLH ARXA45GBLH Low energy consumption by DC fan motor. Selectable with a wide range of static pressure. Selectable with a wide range of static pressure It is possible to change of static pressure range 0 to 50Pa. Can be installed for various location It can be installed in such locations as highrise condominiums by low static pressure design. Static pressure range 0 to 50 Pa It can also be installed in wide spade when high static pressure is required, such as for offices. Easy maintenance See below for the case of rear suction type New model Control box 2.Fan casing 3.Fan 4.Motor Bottom panel: 2 pieces The maintenance of the motor and fan can be easily carried out by removing the rear panel and the lower part of the casing while leaving the main chassis installed. Slim & Compact design In the case of bottom return air connection, not only does the indoor unit design allow for installation in a narrow ceiling space of up to 270, Further space savings have been achieved by mounting the electrical control box internally inside the chassis. Low energy consumption by high efficiency DC fan motor Improved motor efficiency from previous model. Easy setting by using remote controller The change of static pressure range is possible by remote controller Installation styles Embedded in Ceiling Hanging from Ceiling 270,200,35 Control box is now included as part of the main chassis Twodirection drain piping Optional parts One touch operating and easy to install long life filter (Optional Parts) 24 model /36/45 / model Duct indoor unit Twodirection drain piping Remote Sensor Unit : UTYXSZX Long Life Filter : UTDLF25NA Flange (Square) : UTDSF045T Flange (Round) : UTDRF204 IR Receiver Unit : UTBYWC Drain Pump Unit : UTZPXNBA Specifications Dimensions (Unit : ) ARXA24GBLH ARXAGBLH ARXA36GBLH ARXA45GBLH Models: ARXA24 / ARXA / ARXA36 / ARXA45 Power source Capacity V ~, 50Hz *Service accessibility must be allowed for when installing the product. Please consult the installation manual for the necessary service access size. Input power Airflow rate Static pressure range Standard static pressure Sound pressure level Med Low Med Low W m 3 /h Pa db(a) 94, to ,40,2,50 0 to ,840,600,470 0 to ,970,860,0 0 to ø205 hole ø200 (knock out hole) 6 447(Bolt pitch) 73 77(Bolt pitch) Outlet Dimensions (H x W x D) Weight Connection pipe diameter Liquid (Flare) Gas (Flare) kg x,35 x 700 ø9.52 ø5.88 ø 40 Front view 2 Side view (L) P.C.D. ø Top view Side view (R) Drain Note : Specifications are based on the following conditions. ø25 (I.D.) ; ø32 (O.D.) : Indoor temperature of 27 CDB / 9 CWB, and outdoor temperature of 35 CDB / 24 CWB. : Indoor temperature of 20 CDB / (5 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 2 [V]. Refrigerant piping flare connection (Liquid) : 2 Refrigerant piping flare connection (Gas) : 3 Drain piping connection (Drain pipe) Rear view 72 73

38 Indoor units Models ARXC36GBTH ARXC45GATH ARXC60GATH Easy installation (Compact size & Lightweight) Models : ARXC36 A compact size and lightweight indoor unit has been developed by reducing the basic chassis and the overall material weight. Volume 47.5% down Weight 46.5% down 400,050 ARXC36GBTH : 40kg 500 (unit: ) Static pressure selection Models : ARXC36 / ARXC72 / ARXC90 / ARXC96 Max. 200Pa (36 class) Max. 0Pa (72 / 90 / 96 class) Models ARXC72GBTH ARXC90GBTH Low noise Models : ARXC36 / ARXC45 / ARXC60 Cutting off the corners of the conventional indoor unit front panel and fan casing, has enabled less turbulent air flow. Low noise is realized by adopting a plastic case and a plastic fan. By using DC fan motor, it is possible to change static pressure range from 0 to 200Pa (ARXC36) / 0Pa (ARXC72 / 90 / 96). [Pa] 200 or 0 0 [m 3 /h] Air ow rate Low energy consumption by high efficiency DC fan motor Improved motor efficiency from previous model. Models ARXC96GATH N E W Previous model New model (ARXC36GBTH) ARXC36 ARXC72 / 90 / 96 These indoor units allow for high airflow quantities ARXC36GBTH : Plastic fan [42dB(A)] * Model : Material (At 00Pa : Actual noise measurement value) Plastic fan ø Heat exchanger Optional parts Casing (Plastic) 400 LongLife Filter : IR Receiver Unit : Remote Sensor Unit : UTDLF60KA (For ARXC36 / 45 / 60) UTBYWC UTYXSZX Specifications Power source Capacity Input power Airflow rate Static pressure range Standard static pressure Sound pressure level Dimensions (H x W x D) Weight Connection pipe diameter Med Low Med Low Liquid Gas Drain W m 3 /h Pa db(a) kg Note : Specifications are based on the following conditions. *: ARXC60/72/90/96G cannot be connected to JIII series. ARXC36GBTH ,990,6,3 0 to ARXC45GATH ,500 3,000 2, to x,050 x 500 ø9.52 (Flare) ø (Flare) 46 ARXC60GATH* ,500 3,000 2, to V ~, 50Hz ARXC72GBTH* ,900 3,0 3,000 0 to VP25 [ø25 (I.D.) ; ø32 (O.D.)] ARXC90GBTH* ,0 4,000 3,500 0 to x,587 x ø2.70 (Brazing) ø22.22 (Brazing) : Indoor temperature of 27 CDB / 9 CWB, and outdoor temperature of 35 CDB / 24 CWB. : Indoor temperature of 20 CDB / (5 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 2 [V]. ARXC96GATH* ,850 4,250 3,600 0 to Dimensions (Unit : ) Models: ARXC36 / ARXC45 / ARXC60 Models: ARXC72 / ARXC90 Models: ARXC96 400,0(Bolt pitch) 324 4, (Bolt pitch) 88 MAIN DARAIN SAFETY DARAIN 60 2 PORT PORT Rear view Rear view Rear view 85, P60 2 Ø3 50 7= P60 2 P50 7= Side view (R) = Side view (R) = Side view (R) Side view (L) Top view Side view (L) Top view Side view (L) Top view Front view Front view Front view Refrigerant piping flare connection (Liquid) 2 Refrigerant piping flare connection (Gas) 3 Drain piping connection (BOLT PITCH) (Drain hose) (BOLT PITCH) 250 Refrigerant pipe are connection (Liquid) 2 Refrigerant pipe are connection (Gas) 3 Drain hose (BOLT PITCH) 29 (Drain hose) 8 MAIN DARAIN PORT Refrigerant pipe are connection (Liquid) 2 Refrigerant pipe are connection (Gas) 3 Drain hose (BOLT PITCH) SAFETY DARAIN PORT

39 Indoor units Large Airflow Duct Large airflow volume It can be installed in places such as early replacement of air required by large airflow volume. Models ARXN8GATH ARXN24GATH ARXNGATH ARXN34GATH ARXN36GATH ARXN45GATH These indoor units allow for high airflow quantities Selectable with a wide range of static pressure Installation styles static pressure range 50 to 250 Pa static pressure range 50 to 0 Pa ( / 34class) (36 / 45class) Optional parts Remote Sensor Unit : UTYXSZX Specifications Power source Capacity Input power Airflow rate Static pressure range Standard static pressure Sound pressure level Dimensions (H x W x D) Weight Connection pipe diameter Med Low Med Low Liquid Gas Drain W m 3 /h Pa db(a) kg Note : Specifications are based on the following conditions. Large Airflow Duct can be connected to VIII series only. ARXN8GATH ARXN24GATH ARXNGATH ARXN34GATH ,2 50 to ,0 50 to , to V ~, 50Hz 450 x,587 x ø9.52 (Flare) , to VP25[ø25(I.D.); ø32(o.u.)] ARXN36GATH ,20 50 to ø5.88 (Flare) ø (Flare) : Indoor temperature of 27 CDB / 9 CWB, and outdoor temperature of 35 CDB / 24 CWB. : Indoor temperature of 20 CDB / (5 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 2 [V]. ARXN45GATH ,20 50 to Dimensions (Unit : ) Models: ARXN8GATH / ARXN24GATH / ARXNGATH / ARXN34GATH / ARXN36GATH / ARXN45GATH Rear view Air Flow Top view 76 Front view 77

40 Indoor units Double auto swing Super vane Models ABYA2GATH ABYA4GATH ABYA8GATH ABYA24GATH The slim and lightweight design allow the unit to be suspended from the ceiling or installed on the floor. This type suits many room designs Floor standing A combination of up/down and right/left directional swing allows threedimensional air direction control. RIGHT and LEFT SWING steps selectable 4 5 UP and DOWN SWING 3 4 Double Louvre Super vane with newly developed special configuration boosts airflow sending cool air quickly to every corner of the room. Autoclosing louvre When operation is stopped, the louvres will automatically close. (This function is available on all nonducted models.) Compact design Syetrical, slim and compact design. 4 steps selectable Flexible installation Example for floor installation Floor console Example for ceiling installation Under ceiling power DC fan motor power Wide rotation range efficiency (Unit : ) Specifications Power source Capacity Input power Airflow rate Sound pressure level Med Low Med Low Dimensions (H x W x D) Weight Connection Liquid (Flare) pipe diameter Gas (Flare) Drain W m 3 /h db(a) kg ABYA2GATH ABYA4GATH ABYA8GATH ABYA24GATH Note : Specifications are based on the following conditions. : Indoor temperature of 27 CDB / 9 CWB, and outdoor temperature of 35 CDB / 24 CWB. : Indoor temperature of 20 CDB / (5 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 2 [V]. 25 ø6.35 ø V ~, 50Hz 99 x 990 x 5 ø25 (I.D.) ; ø32 (O.D.) , ø9.52 ø , Dimensions (Unit : ) Models: ABYA2 / ABYA4 / ABYA8 / ABYA Refrigerant piping flare connection (Liquid) Refrigerant piping flare connection (Gas) Drain piping connection

41 Indoor units Models ABYAGATH ABYA36GATH ABYA45GATH ABYA54GATH Double auto swing and wide airflow Auto airflow direction and auto swing Right and left 5 steps selectable lift drain pump Optional drain pump unit allows flexible installation design. Fresh air intake Max. 500 Easily concealed in any installation Up and down Fresh air 2 Indoor Outdoor steps selectable power DC fan motor Installation Open Concealed Wall mounted Long airflow Long Airflow ensures comfort to every corner of a large room. power Wide rotation range efficiency (Field Supplied) Long distance airflow General installation pattern which suspends the indoor unit from the ceiling. Installation pattern where part of the indoor unit is embedded into the ceiling. Installation which fixes the indoor unit to the wall by the use of wall brackets (Field supplied). This type of installation can be used when the ceiling space is insufficient. Slim & Compact design t 240 Optional parts Drain Pump Unit : UTRDPB24T Flange : UTDRF204 Specifications Dimensions (Unit : ) ABYAGATH ABYA36GATH ABYA45GATH ABYA54GATH Models: ABYA / ABYA36 / ABYA45 / ABYA54 Power source 2V ~, 50Hz Capacity Input power W Airflow rate,6 2,00 2,270 Med m 3 /h,370,400,600,7 Low,40,70,2,2 Sound pressure level Med db(a) Low Dimensions (H x W x D) 240 x,660 x 700 Weight kg Connection pipe diameter Liquid (Flare) Gas (Flare) ø9.52 ø5.88 ø9.52 ø Drain ø25 (I.D.) ; ø32 (O.D.) Note : Specifications are based on the following conditions. : Indoor temperature of 27 CDB / 9 CWB, and outdoor temperature of 35 CDB / 24 CWB. : Indoor temperature of 20 CDB / (5 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 2 [V]. 2 3 Refrigerant piping flare connection (Liquid) Refrigerant piping flare connection (Gas) Drain piping connection

42 wire OUTDOOR UNIT SIDE UPWARD wire Install the unit as confiremed direction. Install the unit where it will not be tilted by more than 5 INDOOR UNIT SIDE Indoor units Compact size Auto swing louvre Models (EEV internal model) ASYA04GACH ASYA07GACH ASYA09GACH ASYA2GACH ASYA4GACH Models (EEV external model) ASYE04GACH ASYE07GACH ASYE09GACH ASYE2GACH ASYE4GACH Powerful output even compact design Though the indoor unit is compact, it features a large, high pressure cross fan (90 diameter) in a centre mounted configuration and a Lambda type heat exchanger to provide plenty of power. Width 790 The Auto Swing Louvre function ensures that the air direction corresponds to the mode selected. Swing 2 3 Compact and Stylish design indoor 4 Step Swing 790 Easy maintenance Low sound level design Low sound mode of 9dB (A) is realized by DC fan motor mounting and PAM inverter control. Clean filters quality air conditioning by incorporation of high performance filter. Easy maintenance has been realized as the front panel can removed for easy access. Open panel 9dB(A)* At low mode heating operation (ASYE04GACH only) Ion Deodorization Filter The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultrafineparticle ceramic. * This sound level is the same level as the rustling of leaves. Applecatechin Filter Applecatechin filter uses static electricity to clean fine particles and dust in the air. Specifications Power source Capacity Input power Airflow rate Sound pressure level Dimensions (H x W x D) Weight Connection pipe diameter EV Kit (option) Med Low Med Low W m 3 /h db(a) kg Liquid (Flare) Gas (Flare) Drain Note : Specifications are based on the following conditions. ASYA04GACH ASYA07GACH ASYA09GACH ASYA2GACH ASYA4GACH ASYE04GACH ASYE07GACH ASYE09GACH ASYE2GACH ASYE4GACH /440* 320/420* 33 27/32* 22/3* 2V ~, 50Hz /420* 370/420* /3* 27/3* x 790 x 25 9 ø6.35 ø2.70 ø3.8(i.d.) ; ø5.8ø6.7(o.d.) /440* 0/420* 32 26/3* 9/* 2V ~, 50Hz /420* 370/420* /* 26/* : Indoor temperature of 27 CDB / 9 CWB, and outdoor temperature of 35 CDB / 24 CWB. : Indoor temperature of 20 CDB / (5 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 2 [V]. * : This value is under cooling operation x 790 x 25 9 ø6.35 ø2.70 ø3.8(i.d.) ; ø5.8ø6.7(o.d.) UTREV09XB UTREV4XB Dimensions (Unit : ) Models: ASYA04 / ASYA07 / ASYA09 / ASYA2 / ASYA4 ASYE04 / ASYE07 / ASYE09 / ASYE2 / ASYE Refrigerant pipe flare connection (Liquid) Refrigerant pipe flare connection (Gas) Drain piping connection EV kit (UTREV09XB/ UTREV4XB ) Optional parts: UPWARD Install the unit as confirmed direction. Install the unit where it will not be tilted by more than 5 Vertical installation Horizontal installation

43 Indoor units Models ASYA8GACH ASYA24GACH ASYAGACH Double auto swing A combination of up/down and right/left directional swing allows threedimensional air direction control. 5 steps selectable Air conditioner filter features Ion Deodorization Filter Organic coating fin used heat exchanger Simple & Elegant Appearance Design Applecatechin Filter Air Filter 4 steps selectable quality air conditioning by incorporation of high performance filter. More comfort airflow by adopting power diffuser Vertical airflow provides powerful floor level heating Horizontal airflow does not blow cool air directly at the occupants in the room Swing Step Swing Ion Deodorization Filter The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultrafineparticle ceramic. 5 (24/) 5 (24/) Compact & Slim design Applecatechin Filter By using DC fan motor, compact design is realized. Applecatechin filter uses static electricity to clean fine particles and dust in the air. 46 o Power diffuser (full open) (m) Outside air conditions: 2 C 60% Operation contents:, Set temperature (Max set temp) C, airflow Hi, Air direction downward and front ( C) Power diffuser (m) Outside air conditions: 35 C 40% Operation contents:, Set temperature (Min set temp) 8 C, airflow Hi, Air direction downward and front ( C) DC fan motor Easy maintenance Simplification of drain pan cleaning improves maintenanceability. Specifications Dimensions (Unit : ) ASYA8GACH ASYA24GACH ASYAGACH Models: ASYA8 / ASYA24 / ASYA Power source Capacity V ~, 50Hz Input power W ,00,240 Airflow rate Med Low m 3 /h Sound pressure level Med db(a) Dimensions (H x W x D) Low x 998 x Weight Connection pipe diameter Liquid (Flare) Gas (Flare) kg 5 ø9.52 ø Drain ø2 (I.D.) ; ø6 (O.D.) Note : Specifications are based on the following conditions. : Indoor temperature of 27 CDB / 9 CWB, and outdoor temperature of 35 CDB / 24 CWB. : Indoor temperature of 20 CDB / (5 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 2 [V]. 520 Refrigerant piping flare connection (Liquid) 2 Refrigerant piping flare connection (Gas) 3 Drain hose connection 84 85

44 The AIRSTAGE control system can perform air conditioning control of individual room, centralized control by floor or by building, or centralized energy saving air conditioning control for large buildings. A variety of air conditioning management schemes are available to match the application, such as linking with the building control system, linking with a single split models, and using various interfaces

45 Air Conditioning Centralized Control Air Conditioning Individual Control System Controller UTYAPGX UTYALGX (Lite edition) USB Adaptor *2 Software Touch Panel Controller UTYDTGYZ N E W Central Remote Controller UTYDCGY Wired Remote Controller (Touch panel) UTYRNRYZ N E W For All AIRSTAGE TM series Internet or Public Telephone Line (Field supplied) Remote/Monitoring side Group Remote Controller UTYCGGY Network Convertor UTYVGGXZ Wired Remote Controller UTYRLRY Convertor / Adaptor (for external device) Simple Remote Controller UTYRSKY BACnet Gateway UTYABGX Software USB Adaptor *2 BMS/BAS * (Field supplied) Simple Remote Controller UTYRHKY Without operation mode Network Convertor (BMS/LONWORKS ) UTYVLGX MODBUS Convertor UTYVMGX N E W BMS, Home automation system or Wireless Remote Controller UTYLNHY MODBUS Interface FJRCMBS *. BMS/BAS: Building Management System/Building Automation System *2. USB Adaptor: Echelon U0 USB Network Interface KNX Interface FJRCKNXi Service & Maintenance Tool Web Monitoring System UTYAMGX Monitoring Side Software VRF Network System Side Service Tool UTYASGX Software Wireless LAN Interface FJRCWIFI External Switch Controller UTYTEKX Convertor / Adaptor (for system expansion) Network Convertor DC power supply type UTYVTGX N E W AC power supply type UTYVTGXV N E W Single split Single split Internet or Public Telephone Line Outdoor unit Transmission line Web Monitoring Tool USB adapter (Field supplied) USB Adaptor *2 (Field supplied) Cardkey (Field supplied) Internett devicee Network Convertor UTYVGGXZ Signal Amplifier UTYVSGXZ Indoor unit 88 89

46 Max. transmission line length 3,600m Wiring construction of the control system is made of power source wiring, transmission wiring and remote controller wiring. Total wiring length (total length of transmission line) can be extended up to 3,600m (by using signal amplifiers). Item System Controller UTYAPGX Maximum,600 indoor units can be controlled. Air conditioning control Operation monitoring Status monitoring system Electricity charge calculation Refrigerant system Refrigerant system 2 USB Adaptor NW NW 2 NW 3 NW 4 Internet or Public Telephone Line Touch Panel Controller UTYDTGYZ One Touch Panel Controller can control up to 400 groups / 400 indoor units. (Remote / Monitoring side) Max. controllable remote controller groups Max. controllable indoor units Max. controllable groups On / Off Wired Remote Controller (Touch panel) UTYRNRYZ 6 Wired Remote Controller UTYRLRY 6 Simple Remote Controller UTYRSKY 6 Simple Remote * Controller UTYRHKY 6 Wireless Remote Controller UTYLNHY 6 Group Remote Controller UTYCGGY 8 28 Central Remote Controller UTYDCGY Touch Panel Controller UTYDTGYZ System Controller Lite Software UTYALGX System Controller Software UTYAPGX Building Management System BACnet BACnet Operator Workstation (BOWS) LONWORKS Web Monitoring Tool Trouble free operation at all times by remote monitoring system. (Monitoring side) BACnet Gateway UTYABGX Transmission line line is nonpolar 2conductor. (Monitoring side) BACnet USB Adaptor LONWORKS Network Web Monitoring Tool UTYAMGX Internet or Public Telephone Line Network Convertor for LONWORKS UTYVLGX Network Convertor UTYVGGXZ Signal Ampli er UTYVSGXZ (VRF network system side) (Monitoring side) System without Remote Controller Together with Touch Panel Controller, it is possible to build non remote controller system. USB Adaptor Service Tool UTYASGX USB Adaptor Central Remote Controller UTYDCGY Maximum 00 indoor units can be controlled. Group Remote Controller Maximum 8 remote controller groups can be controlled Remote Controller line Maximum 6 units can be controlled 2 Remote Controllers Indoor unit can be controlled from both remote controllers. Service Tool Extensive monitoring and analysis functions for installation and maintenance. Outdoor unit Indoor unit (Cassette) Indoor unit (Duct) System Controller Touch Panel Controller Central Remote Controller Group Remote Controller Wired Remote Controller (Touch panel) Wired Remote Controller Simple Remote Controller Simple Remote Controller Wireless Remote Controller IR Receiver Unit Cassette type indoor unit can be controlled with Wireless Remote Controller IR Receiver Unit Duct type indoor unit can be controlled with Wireless Remote Controller. Card key External Switch Controller Indoor units can be controlled by combining with Cardkey switch such as hotel room. Network Convertor UTYVGGXZ Single system External Switch Controller IR Receiver unit RB unit (Single) RB unit (Multi) Transmission line Module link Remote Controller line (2 wires) Remote Controller line (3 wires) USB cable LONWORKS Network Ethernet Signal line (single system) Group Remote Controller line Control Timer Display Air conditioning control function Operation mode setting Fan speed setting Room temp. setting Room temp. set point limitation Test operation Up/down air direction flap setting Right/left air direction flap setting Group setting RC prohibition Anti freeze setting Economy mode setting Error Defrosting Current time Day of week R.C. prohibition /heating priority Address display Room temp Multi language Suer time Name registration Backlight 2D floor layout / 3D building display Schedule timer On/off timer Sleep timer Program timer Auto off timer Day off Min. unit of timer setting (Minutes) Status monitoring system Electricity charge apportionment Error history Emergency stop Remote management Energy saving management notification for malfunction Key lock Period On/off, Temp, Mode, Times per day Week 8 0 Child lock Week 4 Child lock * "Operation mode" setting is not available for this model. : Supported *2 This function is available only through external input control. 5 Week 4 0 Child lock Week 20 0 *2 Password setting Year 20 0 *2 Password setting Year 44 0 Password setting Year 44 0 Password setting : Optional function : Not supported yet 90 9

47 Individual Controller UTYRNRYZ Easy operation by highdefinition large STNLCD touch panel screen Easy finger touch operation with LCD panel Builtin weekly/daily timer(on/off,temp.,mode) Backlight enables easy operation in a darkened room Room temperature display Control up to 6 indoor units Corresponds to 2 different languages (English, Chinese, French, German, Spanish, Russian, Polish, Italian, Greek, Portuguese, Turkish and Dutch) Functions performance and compact size In addition to the individual control, various energy saving controls can be realized using one remote controller only. Individual control Thermo sensor N E W Weekly timer Auto off timer Accurate and comfortable control Indoor temperature can be detected accurately by the inclusion of a thermo sensor in the body of the wired controller. Various energy saving control Auto OFF Timer The indoor unit automatically turns off after a set time has passed. The time interval for which auto off works can be set. Ex) At interval time hour (7:00 to 24:00) to prevent forgetting to turn off Set interval time hour (7:00 to 24:00) Set off time ( to 240 minutes) 7:00 24:00 2 schedules Weekly Timer 2 schedules such as for the suer and winter can be set. 8 setting changeable per day of week (Setting items: On/Off, Temperature, Mode, Time) Ex) Setting temp. ON 26 C 24 C Schedule (Suer schedule) OFF OFF Time 8:40 :40 7: 20:40 Set Temperature Auto Return The setting temperature automatically returns to the previous setting temperature. The time range in which the set temperature can be changed is 0 to 20 minutes. ON Setting temp. ON 25 C 23 C Max. controllable 6 indoor units Auto OFF OFF Schedule 2 (Winter schedule) OFF OFF Time 8:40 0:00 5: 7: 20:40 Various convenient functions Displays setting status and Limitations The remote controller settings can be easily checked Simplified installation Uses nonpolar 2wire type The faulty wiring can be prevented by using nonpolar 2wire. Easy Maintenance Suer Time display This function can be set easily from Menu screen OK Error History Display The errors that occur in the indoor unit or remote controller are saved as a history. A maximum of 32 error incidents can be saved. I.U. Y Y2 Y3 I.U. Y Y2 Y3 nonpolar 2wire OK Y Y2 Y Y2 Initial Setting Language Setting Temp. Unit Setting Back Child lock Lock / unlock method: Push the ON/OFF button and the screen (4 seconds) Auto Address Setting/Setting Position Notification Reduce errors and install time compared with the current specification Rotary SW When will be set remote controller groups, can also be set automatically new Wired remote controller address After auto address setting of new wired remote controller groups, what number can also confirm addresses Address Date Setting Page / 3 R.C.Group Name Setting Next Page Name Registration Remote controller names can be registered in the remote controller screen. This makes it easy to identify the indoor unit you want to control in the room. The appropriate indoor unit performs the air blow and LED lamps blink. Room temperature sensor Room temperature display operation operation Setting temp. Set temperature change Auto return Setting temp. Set temperature change Auto return 24 C 25 C 22 C 23 C Settable time range Settable time range 0 to 20 minutes 0 to 20 minutes Time Time :40 3:40 :40 3:40 Backlight Backlight enable easy operation in a darkened room. For the lighting time of Backlight, or 60 seconds can be set. Backlight activates while the buttons are operated and goes off or 60 seconds after the operation stops. Set Temperature Upper and Lower Limit Setting The set temperature range can be set for each operation mode. ( / / Auto) C 25 C 8 C Original temp. setting range During Lower limit setting C 25 C 0 C Original temp. setting range During Upper limit setting Specifications Power Supply Dimensions (H x W x D) () Weight (g) DC2V is supplied by the indoor unit. UTYRNRYZ DC 2V 20 x 20 x

48 Individual Controller Max. controllable 6 indoor units Max. controllable 6 indoor units UTYRLRY UTYRSKY / UTYRHKY (Without Operation mode) Various timer setup (ON / OFF / WEEKLY) are possible. The room temperature can be controlled by detecting the temperature accurately with Builtin thermo sensor. When a failure occurs, the error code is displayed. Error history. (Last 6 error codes can be accessed.) 2wire type Compact remote controller provides access to basic functions Up to 6 indoor units can be controlled with one remote controller. Suitable for hotels or offices as it is easily operated with no complex functions. UTYRSKY UTYRHKY Without Operation mode Functions Functions performance and compact size In addition to the individual control, weekly timer, and various energy saving controls can be realized using only one remote controller. Individual control Thermo sensor Weekly timer Auto OFF timer visibility and easy operation "Mode", "Set Temp", and "Fan" are displayed at large size on the top screen. Each function to be set is indicated by an icon. Control guide is displayed and operation is simple and straightforward. Sophisticated control buttons Simple operation with easy 4way navigation pad Set contents can be displayed clearer with large LCD. Userfriendly operation Provides access to basic operations, such as Start / Stop, Fan control, Operation mode switching, and Room temperature setting. A large On / Off button is provided in the centre of the remote controller for easy operation. Can be used jointly with other individual control unit. Following an error display, diagnostics can be carried out on the controller. Backlight Backlight enables easy operation in a darkened room. Backlight activates during all button operations, and lasts 0 seconds in Operation mode and 5 seconds in stop mode after a button is pressed. Autooff timer The indoor unit automatically turns off after a set time has passed. Operation status ON Auto OFF Auto OFF Set temperature auto return The setting temperature automatically returns to the previously set temperature. The time range in which the set temperature can be changed is to 240 minutes. Simple installation Can be mounted on the European Mounting Box (Installation dimension: 60) or the JIS Builtin Box (Installation dimension: 83.5). 60 Functions suary Model Operation UTYRSKY UTYRHKY OFF Autooff timer can be set from to 240 minutes operation Setting temp. 24 C 22 C Set temperature change Settable time range to 240 minutes Auto return Time operation Setting temp. Set temperature change Auto return 25 C 23 C Settable time range to 240 minutes Time European switch box JIS builtin box 83.5 On / Off Fan control Operation mode Room temp. setting * Weekly timer function Set temperature upper and lower limit setting *: "Operation mode" setting is not available. It is recoend to use together with other type controller. Not only time setting On / Off, but also setting of the operation mode and set temperature can be set by Weekly timer function. The set temperature range can be set for each operation mode. ( / / Auto) 24 C ON OFF ON OFF C During C During Working hour Working hour 25 C 25 C 8:00 2:00 3:00 7:00 4 types (ON, OFF, ON, OFF) can be set on every day of the week in a week. 8 C Original temp. setting range Lower limit setting 6 C Original temp. setting range Upper limit setting Specifications Specifications UTYRLRY UTYRSKY UTYRHKY Power Supply DC 2V Power Supply DC 2V Dimensions (H x W x D) () 20 x 20 x 7 Dimensions (H x W x D) () 20 x 75 x 4 Weight (g) 70 Weight (g) 90 DC2V is supplied by indoor unit. DC2V is supplied by the indoor unit

49 Individual Controller UTYLNHY Simple and sophisticated operations with a choice of 4 daily timers A single controller controls up to 6 indoor units. Max. controllable 6 indoor units Selectable 4 daily timers UTBYWC Necessary to control for all Duct types* by Wireless Remote Controller *Only Large Airflow Duct can not be connected to IR Receiver Unit. Up to 6 indoor units can be controlled with one remote controller. Suitable for hotels or offices as it is easily operated with no complex functions. Functions Wiring connection Builtin daily timer Easy installation and operation Select from 4 different timer programs : On / Off / Program / Sleep Program timer : The program timer operates the ON and OFF timer once within a 24 hour period. Sleep timer : The sleep timer function automatically corrects the set temperature according to the time setting to prevent excessive cooling or heating during sleep hours. Code selector switch prevents indoor unit mixup. (Up to 4 codes can be set.) Duct Type Indoor Unit IR Receiver Unit Wireless Remote Controller operation/dry operation Wide and precise Specifications When the sleep timer is set, the set temperature automatically rises C every hour. The set temperature can rise up to a maximum of 2 C. UTBYWC Power supply DC 5V Timer setting Dimensions (H x W x D) () 45 x 90 x Weight (g) 50 60min. operation C 2 C Address setting During installation work, address setting can be performed using the Wireless Remote Controller, thus eliminating manual switch setting. When the sleep timer is set, the set temperature automatically drops C every minutes. The set temperature can drop to a max. of 4 C. C 2 C 3 C 4 C Outdoor unit RB unit Transmission line Indoor unit UTYLRHYB Cassette type indoor unit can be controlled with Wireless Remote Controller min. Wireless Remote Controller 60min. 90min. Timer setting Wireless Remote Controller Specifications Specifications UTYLNHY UTYLRHYB Power supply.5v (R03 / LR03 / AAA) x 2 Power Supply DC 5V Dimensions (H x W x D) () 70 x 56 x 9 Dimensions (H x W x D) () Weight (g) 85 Weight (g)

50 Centralized Controller UTYCGGY Group control of indoor units with simple operation Up to 8 remote controller groups can be controlled by one Group Remote Controller. Up to Group Remote Controllers can be connected in one VRF network system. Network Convertor (UTYVGGXZ) is required to connect Group Remote Controllers to a VRF network system. (Network Convertor allows up to 4 Group Remote Controllers) Control up to 8 remote controller groups Single Group Remote Controller controls and monitors up to 8 remote controller groups. Hotel Office & Lounge Refrigerant system Refrigerant system 2 Guest room Max. controllable 8 remote controller groups Max. controllable group R.C. in a VRF network system UTYDCGY Central control of small and mediumsized buildings and tenants. The operation status of all connected indoor units can be viewed at a glance on a large LCD monitor to simplify individual control to batched control. Individual control and monitor of 00 indoor units 5 inch TFT color screen User friendly view and easy operation External input / output contact Detachable power supply unit Corresponds to 7 different languages (English, Chinese, French, German, Spanish, Russian, Polish) System overview It allows multiple indoor units grouping (Max.6 groups controlled) Interlock with external device Group : 3F Group : Division A Group : 2F Group : Division B Group : Hallway Max. controllable 00 Indoor units Max. controllable 6 groups Group : Division C Group : Tenant A Group : Tenant B Group : Tenant C Restaurant Emergency stop function Lobby Network Convertor Office room Restaurant Lounge Group Remote Controller : To control office room, lounge, restaurant and lobby (8 remote controller groups) Functions Diverse control of indoor units Remote controller prohibition Weekly timer Error history (All, On / Off, Mode, Temp, Timer, Filter) Automatic clock adjustment 2 Group Remote Controller Lobby Group Remote Controller 2: To control guest room and launge (7 remote controller groups) Easy Installation performance and compact size ON / OFF, Operating mode, Room temperature and Fan speed setting can be controlled / monitored centrally or individually. Central control ON/OFF control Weekly timer Builtin weekly timers The weekly timer is provided as a standard function.. The timer can be set up for up to 4 times per day. (On / Off, operating mode, set temperature) 2. Allows separate settings for each day of the week. The control panel and power supply unit can be installed separately. For flexibility in installation, the Control panel can be built into the wall or fix on the wall. Setting pattern Setting pattern 2 Power supply unit Power supply unit Ceiling Automatic or manual indoor unit registration Indoor unit registration start Indoor unit registration RB Unit Control panel Wall Control panel Control panel + Power supply unit Wall Indoor unit registration finish Specifications UTYDCGY Specifications Power Supply Control Panel DC 5 V Power Supply Unit 00240V, 5060Hz, Single phase UTYCGGY Dimensions (H x W x D) () 20 x 62 x x 35 x 39.2 Power Supply DC 2V Weight (g) Dimensions (H x W x D) () 20 x 20 x 8 <PACKING LIST> Weight (g) 200 Packing List Control Panel / Power Supply Unit / Connecting cable, etc. DC2V is supplied by a network converter

51 Centralized Controller Max. controllable 400 Indoor units Up to 400 indoor units can be controlled UTYDTGYZ N E W visibility and easy operation via high resolution 7.5 inch TFTLCD touch panel screen 6 RB Unit Group A Group B Largesized 7.5inch TFT color LCD Easy finger touch operation Stylish shape and design to suit all application Up to 400 indoor units can be controlled Selectable 2 display types (Icon / List) in monitoring mode Supports 7 differentlanguages,english, Chinese, French, German, Spanish, Russian, Polish. Mounted with LAN interface for remote control & operation, external input / output with emergency stop and batch ON / OFF Emergency stop control Air conditioner can be turned off through the external input control It allows multiple indoor unit grouping Emergency stop function Functions Diverse operation management Outdoor unit low noise setting Automatic clock adjustment Emergency stop function Individual control Flexible grouping Schedule control Indoor units operation monitoring Remote monitoring and operation Air conditioner can be monitored and controlled via LAN from PC. Error contents are notified automatically by at error occurrence to handle the trouble promptly. Operation status monitoring Error notification by LAN or Internet Operation mode setting VRF network system Electricity charge apportionment (Option: UTYPTGXA) Electricity charge apportionment can be performed easily for thr power consumed when billing users for air conditioning power charges. Electricity charges VRF network system Block (Tenant) A Electricity meter Signal line* Electric power company Easy operation Easy maintenance LAN cable Block (Tenant) B *: Electricity meter (unit) can be connected to external input connector of the TPC unit. In this case, electricity meter cannot be connected to outdoor unit simultaneously. Large and wideangled LCD is easily viewable even at a distance Easytounderstand icondriven Graphical User Interface (GUI) Wide range of simpletounderstand icons Flat touch screen is easily cleaned Nonglare coating on touch panel controller minimizes fingerprint marking Easytoremove front cover Specifications UTYDTGYZ Operation can be selected using your finger or the dedicated touch pen by pressing the appropriate onscreen icon Uptodate status display Background color identifies current control operation Blue for monitoring, green for operational control Easy installation Touch Panel Controller is easily mounted to the wall. Flat back surface allows to be installed wherever it is needed. No additional component is required for installation. Power Supply Dimensions (H x W x D) () Weight (g) Interface 00240V 50/60Hz, Single phase 260 x 246 x 54 2,50 Transmission / LAN / USB / EXT IN / EXT OUT / Reset SW 00 0

52 Centralized Controller UTYAPGX System Controller realizes the advanced integrated monitoring & control of VRF network system from small scale buildings to large scale buildings. Up to a maximum of 4 VRF network systems, 600 indoor units, and 400 outdoor units can be controlled. In addition to air conditioning precision control function, central remote control, electricity charge calculation, schedule management, and energy saving functions are strengthened and building manager and owner needs are met. UTYALGX System Controller Lite has standard functions sufficient for air conditioner management in small and medium scale buildings. Up to a maximum of VRF network system, 400 indoor units, and 00 outdoor units can be controlled. In addition to air conditioning precision control function, a variety of management software is available as an option to give customers a wide range of choice. Software Software Max. controllable 4 VRF network systems Max. controllable 400 Outdoor units Max. controllable,600 Indoor units Max. controllable VRF network systems Max. controllable 00 Outdoor units Max. controllable 400 Indoor units Diverse operation management & Data management Schedule management Annual schedules can be set for each remote controller group / user defined group. Start / stop, operating mode, remote controller prohibition, and temperature settings can be set up to 43 times per day at 0 minute intervals for up to 0 configurations for each remote controller group. Settings can be made for periods straddling midnight. Allows prograing of special settings for holidays, including public holidays, for a complete year. Low noise operation of outdoor unit can be scheduled. Diverse control of indoor and outdoor unit Indoor unit operation state, operation mode, etc. are displayed Indoor unit start / stop and operation mode switching Room temperature set point limitation Outdoor unit low noise setting Standard for System Controller and System Controller Lite Error display & notification Error is notified with popup message, audible sound and real time when error occurs. Error for the past year are logged and can be reviewed later. Operating & control record Displays the history of operation status and control. Data base import/export Imports/exports registration data, layout data, and image data. Only the administrator can make this setting. Functions Remote controller prohibition Automatic clock adjustment User friendly view and operation Click & Operate : The property is shown visually from the perspective most suitable for operation and operated accordingly (Click & Operate). You can select from among the 4 displays of site, building, floor, or list. Freely define groups for batched control : Indoor units can be freely grouped for simple batched control from a tree menu. Grouping by hierarchal structure, such as by section, division or department is possible. This prohibits changes to the operation mode, temperature, start/stop, etc. The time setting of each controller can be set in batch automatically. Click & Operate the whole building! Site view Properties can be shown using one of the four displays of site, building, floor, or list. The display is easily changed by pressing the button. Click & Operate any specified unit(s)! List view Electricity charge apportionment Standard Option Electricity charge apportionment calculation framework Suppose you want to find the power consumed by the air conditioners of each tenant from the electricity charge for each month. With electricity charge apportionment function, used energy apportionment ratio will be provided, calculating in detail the energy consumed by the units used by each tenant. This information is then used to calculate the charges for the electricity consumed for air conditioning by each tenant from the total electricity charges in the bill from the electric power company. (See figure at right) The detailed calculation takes into consideration such things as unused rooms and nighttime electricity charges and shows them in a charges calculation sheet. for System Controller for System Controller Lite UTYPLGXA Energy used by each unit is calculated Tenant A Tenant B Energy apportioned by the outdoor unit to each indoor unit is calculated Tenant A Tenant B System Configuration Example Tenant C Tenant C 02 Batched control of freely defined groups Batched control of freely selected units Note: 2D floor layout / 3D building display are not available for System Controller Lite. Click & Operate the whole floor! Batched control of freely selected units Building view The floor layout drawing can be imported to easily make the settings for the actual building. Floor view Click & Operate the unit! Powe r distribuibu bution board Electric power company Outdoor unit System Controller 3Ø, 4 wire 400V, 50Hz Electricity charges (air conditioning) RB Unit Tenant A Tenant A2 Tenant A3 Tenant A4 Tenant A5 Tenant A6 Tenant B Tenant B2 Tenant B3 Tenant C Tenant C2 Tenant C3 Signal transmission line Powe r distribuibu bution board Ø, 2wire 2V, 50Hz Electricity charges by tenant are calculated The distribution ratio for energy used by each indoor unit is calculated and the electricity charges for the energy used by each indoor unit are calculated from the total electricity charges. Tenant A Electric Bill Tenant B Electric Bill Tenant C Electric Bill The energy used by each indoor unit and the energy apportioned by the outdoor unit are added together to calculate the total amount of energy used. Indoor unit energy used Apportioned energy Indoor unit total energy used 03

53 Centralized Controller FUNCTIONS SUMMARY System controller Remote management Function Standard for System Controller Option for System Controller Lite UTYPLGXR System Controller may be used on site or remotely over various networks for remote central control. System Controller requires 2 softwares working together. VRF Controller runs on site and counicate with VRF system. VRF Explorer runs remotely and provides user interface and counicate with the VRF Controller. VRF Controller and VRF Explorer program may run in a single PC or in different PCs separated by network. By using VRF Explorer software, one PC can perform central control of 0 VRF system sites with max. 20 buildings per site. System specification Remote central control VRF Explorer can control or monitor up to 0 sites. VRF Explorer VRF Controller Site supervision Building management company, management center, etc. A maximum of 0 locations, such as offices or factories Error management VRF Controller History Internet or Telephone Line or LAN On site central control Max. 4 VRF network systems per site Internet or Telephone Line or LAN Operation control VRF Controller can be monitored from any number of VRF Explorers (Up to 5 connections simultaneously). VRF Explorer Central Monitoring Screen for all Properties VRF Explorer Building Management Company A (In charge of the day shift) VRF Explorer VRF Explorer Schedule Building Management Company B (In charge of the night shift) Internet or Telephone Line or LAN Office Management Center Remote manageent VRF Controller VRF Explorer VRF Explorer Electricity charge apportionment Security Company Headquarters Management Center Special Property Detailed Monitoring Screen Energy saving management Energy saving management Option Option for System Controller UTYPEGX for System Controller Lite UTYPLGXE A variety of energy saving operations can be set and managed depending on the season, weather, and time period. Excellent energy saving operation is performed while keeping users comfortable. Energy saving graph data: This graph compares the electricity consumption with the previous month and previous year to make it easy to analyze the energy saving effect. Energy Saving Management Main Screen Others Max. VRF networks supported Max. indoor unit / remote controller groups per VRF network Max. outdoor units per System controller Max. indoor units / remote controller groups per System controller Max. outdoor units per System controller Multi site display Number of building / site Number of floor per site Number of floor per building 3D graphical layout view 2D graphical layout view List display Tree display Group display Error notification Audible alarm Error notification Error history Operation history Control history On/Off Operation mode Room temperature Fan speed Individual Air flow direction control Economy mode Room temperature set point limitation Test operation Antifreeze Outdoor unit low noise setting Remote control prohibition setting Individual Temperature upper and lower limit setting management Filter sign reset Memory operation Other Pattern operation Annual Schedule Special day setting On /off per day On / off per week Day off Min. unit of timer setting (Minutes) Low noise mode Weekly schedule Remote monitoring Remote operation control Remote function setting Apportionment charge/bill calculation Tenant (block) setting Coon facilities apportionment setting Rated power consumption allotment setting Individual calculation at cooling and heating Electricity meter supported Indoor unit rotation Peak cut control Outdoor unit capacity save Record of energy saving operation Energy saving information Power consumption monitor Electricity meter supported Database import/export Automatic clock adjustment Multi language languages Option UTYPLGXR Option UTYPLGXA Option UTYPLGXE 7 languages Personal computer system requirements The operation of indoor units can be automatically rotated within a group in accordance with the set annual schedule to reduce power consumption while maintaining comfort. The indoor unit operation stoppage rate can be selected. Outdoor unit capacity save switches the outdoor unit capability upper limit to suppress power consumption during hot suers and cold winters by averaging the power saving effect of each refrigerant system. You can select from 50% or more of the capacity upper limit. Power consumption Outdoor unit capacity save Outdoor O td unitit capacity it control screen UTYALGX * A power meter is connected to detect the total power consumption while shifting the indoor unit set temperature, set the indoor unit forced thermostat off, and taking other measures to carefully control the power consumed Forced thermostat off range while maintaining comfort Outdoor unit stop range Target power consumption and conducting control to maintain the target power consumption set for each time. The indoor units to Ideal control line be controlled can be (Use of average power consumption) freely grouped and the control level can be set. Shows change in power consumption by time Cold day of winter System controller lite Option UTYPEGX : Available. : Not available. *:Power calculation application software is necessary, please contact the local FGL representative. Hot day of suer 04 UTYAPGX Peak cut operation Indoor unit rotation operation IIndoor d unitit rotation t ti screen Type Outdoor unit capacity upper limit Operating system System Controller System Controller Lite Microsoft Windows Vista Home Premium (32bit) SP2, Windows Vista Business (32bit) SP2 Microsoft Windows 7 Home Premium (32bit or bit) SP, Windows 7 Professional (32bit or bit) SP Microsoft Windows 8. (32bit or bit), Windows 8. Pro (32bit or bit) Microsoft Windows 0 Home (32bit or bit), Windows 0 Pro (32bit or bit) [Supported languages] English, Chinese, French, German, Russian, Spanish, and Polish CPU Intel CoreTM i3 2 GHz or higher Memory 2 GB or more (for Windows Vista and Windows 7 [32bit]) 4 GB or more (for Windows 7 [bit], Windows 8., and Windows 0) HDD Display 40 GB or more of free space 024 x 768 or higher resolution Interface Ethernet port (for getting access to the Internet using LAN) or Modem (for getting access to the Internet using Public Telephone Line) USB ports (Maximum of 6 ports) (Required only for the Server PC that works as VRF Controller) Maximum of 2 USB ports are required for WibuKey connection Maximum of 4 USB ports are required for Echelon U0 USB Network Interface * Maximum number of required USB port depends on the applicable system configuration. Graphic accelerator Software Optical drive Microsoft DirectX 9.0c compatible Adobe Reader 9.0 or later DVDROM drive Personal computer that satisfies the following system requirements Echelon U0 USB Network Interface TP/FT0 Channel (Model number: 7500R) (Required for each VRF Network.) <Packing list> For System controller Type Time Ethernet port (for getting access to the Internet using LAN) or Modem (for getting access to the Internet using Public Telephone Line) USB ports (Maximum of 5 ports) (Required only for the Server PC that works as VRF Controller) Maximum of 4 USB ports are required for WibuKey connection USB port is required for Echelon U0 USB Network Interface * The maximum number of required USB port depends on the applicable system configuration. DVDROM WibuKey*(Software protection key) System controller UTYAPGX Option Energy manager UTYPEGX For System controller Lite System Controller Lite UTYALGX Option Remote access UTYPLGXR ņ Electricity charge apportionment UTYPLGXA ņ *:Software protection key to be inserted in a USB slot running System Controller or System Controller Lite. System Controller or System Controller Lite may only run on a PC with Wibu Key. However, WibuKey is not required for remote VRF Explorer software. Energy saving UTYPLGXE ņ 05

54 Convertor / Adaptor UTYABGX Max. controllable 4 VRF network systems Max. controllable 400 Outdoor units UTYVLGX Max. controllable 4 Units to BMS Max. controllable 00 Outdoor units It is possible to connect medium to large sized BMS to VRF network system via BACnet, a global standard for open networks. A maximum of 600 indoor units with 4 VRF network systems (a maximum of 400 indoor units & 00 outdoor units for one network system) can be connected to one BACnet Gateway. It is possible to control or monitor VRF network system from BMS via BACnet Gateway. Compatible with BACnet (ANSI / ASHRAE352004) application specific controller (BASC). Compatible with BACnet /IP over Ethernet. Scheduling function, Alarm & Event functions as well as Electricity Change Apportionment function are provided in BACnet Gateway. Connection between VRF network system to personal computer is possible via small U0 USB interface. However, both U0 USB interface & personal computer are field supplied items. Corresponds to 7 different languages, English, Chinese, French, German, Spanish, Russian, Polish. Max. controllable,600 Indoor units For connection between VRF network system and a LONWORKS open network for management of small to mediumsized BMS and VRF network system. The UTYVLGX permits central monitoring and control of a VRF network system from a BMS through a LONWORKS interface. Up to 28 Indoor units can be connected to one Network Convertor for LONWORKS Installation example Max. 00 outdoor units Max. controllable 28 Indoor units Max. 28 indoor units Installation example VRF network system RB Unit Indoor unit Outdoor unit USB adaptor * (Field supplied) BACnet BACnet Operator Workstation (BOWS) Generalpurpose building control computer (LONWORKS device) Max. 4 Network Convertor RB Unit RB Unit RB Unit VRF network system 2 RB Unit Outdoor unit Indoor unit USB adaptor (Field supplied) USB adaptor (Field supplied) BACnet Gateway (UTYABGX) Lighting facilities Security system Automatic fire alarm interface Ventilation system Lighting facilities Security system Automatic fire alarm interface Max. 00 outdoor units VRF network system RB Unit Max. 28 indoor units Max. 4 VRF network systems USB adaptor (Field supplied) DVDROM (Software) Software Protection Key = USB cable = Transmission line (VRF Network) = Ethernet *: USB adaptor is U0 USB Network Interface of Echelon Corporation. Ventilation system RB Unit Personal computer system requirements UTYABGX LONWORKS Network RB Unit VRF network system 2 Operating system Microsoft Windows Vista Home Premium (32bit) SP2, Windows Vista Business (32bit) SP2 Microsoft Windows 7 Home Premium (32bit or bit) SP, Windows 7 Professional (32bit or bit) SP Microsoft Windows 8. (32bit or bit), Windows 8. Pro (32bit or bit) Microsoft Windows 0 Home (32bit or bit), Windows 0 Pro (32bit or bit) [Supported languages] English, Chinese, French, German, Russian, Spanish, and Polish Specifications UTYVLGX Dimensions (Unit : ) CPU Memory HDD Display Interface Software Optical drive <Packing list> Name and shape DVDROM Wibu Key (Software protection key) Quantity Intel Core TM i3 2 GHz or higher 2 GB or more (for Windows Vista and Windows 7 [32bit]) 4 GB or more (for Windows 7 [bit], Windows 8., and Windows 0) 40 GB or more of free space 024 x 768 or higher resolution Ethernet port (for getting access to the Internet using LAN) USB ports (Maximum of 5 ports) USB port is required for WibuKey connection Maximum of 4 USB ports are required for Echelon U0 USB Network Interface * Maximum number of required USB ports depends on the applicable system configurations. Adobe Reader 9.0 or later DVDROM drive Application Includes the software and manuals for BACnet Gateway. Software protection key to be connected to USB port on the BACnet installed PC. BACnet Gateway runs only on a PC with WibuKey. Personal computer that satisfies the following system requirements Echelon U0 USB Network Interface TP/FT0 Channel (Model number: 7500R) (Required for each VRF Network.) Power Supply Power Consumption (W) Dimensions (H x W x D) () Weight (g) 2040V 50/60Hz, Single phase Transmission specifications (BMS side) Transmission speed Transceiver Transmission way form Terminal resistor x 288 x 2, kbps FTX (Echelon Corporation) Free topology None (It attaches at the terminal of a network.) 06 07

55 Convertor / Adaptor Max. connectable 9 units to one VRF UTYVMGX N E W The MODOBUS Convertor allows a complete integration of air conditioners into MODBUS Networks. Compact and lightweight design Direct connection to MODBUS Network Up to 28 indoor units can be controlled in one MODBUS Convertor The MODBUS Convertor permits central monitoring and control of air conditioners from BMS or Central Controller. Max. controllable 00 outdoor units Selectable 28 indoor units FJRCMBS The Modbus Interface allows a complete integration of air conditioners into Modbus Networks. Simple installation due to small and compact size. No separate external power supply required. The Modbus Interface permits central monitoring and control of air conditioners from BMS,. Functions Modbus Network Max. 63 Modbus Interface The Modbus Interface can be used with or without Wired Remote Controller. The Solution for integrating VRF Systems into small and medium sized buildings by Modbus method. BMS/Central Controller VRF Indoor unit VRF Indoor unit BMS/Central Controller Controller Lighting facilities MODBUS Network MODBUS Convertor for VRF VRF System (Lon Network) VRF Indoor unit VRF Indoor unit Wired Remote Controller Split Indoor unit Security system Automatic fire alarm interface Windows bind * BMS : Bulding Management System VRF Outdoor unit FJRCKNXi The KNX Interface allows a complete integration of air conditioners with KNX Network systems. Connectable MAX 9 Up to 9 convertors can be connected to a VRF network. The simultaneous controls such as ON/OFF or temperature settings can be done for each zone. Traceability of sources of connection error It is easy to locate the source of error if any connection errors should occur after completion of installation works. Simple installation due to small and compact size. No separate external power supply required (just KNX bus power). Can be used for single indoor units and group controlled (up to 6) indoor units Hotel Office & Lounge Tenant A Tenant B Example : If any connection error occurs, it will tell you where the problem is in either BMS controller to MODBUS Convertor or VRF system to MODBUS Convertor, Test Run ON! Check item! Faulty wiring check Address check KNX Network Home Controller Lighting facilities KNX The KNX Interface can be used with or without Wired Remote Controller. or VRF Indoor unit Restaurant Security system Lobby Tenant C BMS/Central Controller MODBUS Network MODBUS Convertor Automatic fire alarm interface Windows bind Wired Remote Controller Split Indoor unit Specifications Specifications UTYVMGX FJRCMBS FJRCKNXi Power Supply V 50/60Hz, Single phase Dimensions (H x W x D) () Dimensions (H x W x D) () Input power (W) Max. 2 Weight (g) 85 Weight (g) 70 Dimensions (H x W x D) () Weight (g),

56 Convertor / Adaptor FJRCWIFI It is the most advanced solution to remotely manage an Air Conditioning system using all sort of mobile devices such as Smartphones, Tablets and PC No separate external power supply required Can be used for single indoor units and group controlled (up to 6) indoor units UTYVTGX (DC power supply type) UTYVTGXV (AC power supply type) N E W N E W The network convertors are required when connecting single split system to VRF network system. Compact and light weight design Connectable to both types of 2wire and 3wire remote controllers UTYVTGX DC power supply type UTYVTGXV AC power supply type Max. controllable 6 single indoor units Max. controllable 00 Network Convertors Indoor unit Functions Internet Smartphone Installation example Wireless LAN Interface Tablet 2 types of remote controller type and 2 remote controllers type are available. Power supply (AC220240V, 50/60Hz) is required for 2 remote controllers type. Router (Field supplied) PC VRF network System Network Convertors (for remote controller) Network Convertors (for 2 remote controllers) AC2V Basic control Turning the units on and off Mode control (Heat, Cool, Dry, Auto, Fan) Fan speed setting Louver position (Airflow direction setting) Room temperature display Set temperature control Multi Language One Scene and Timer (Application screen image) 2wire and 3wire type of the wired remote controller can be connectable. Power supply (AC220240V, 50/60Hz) is required for 2 remote controllers type. A central control can be provided for the single split systems. (Up to 00 units of Network Convertor is connectable in one VRF network system) VRF network System VRF network System Advanced control (Optional functions) Notifications and History Up to 00 units of Network Converter Climate working modes (ECO, Comfort, Powerful) (future release) Schedulable functionalities (ON/OFF, Modes, Set point temperature, Fan Speed, Louver position) Set temperature limitation (future release) Multiple Scenes & Timers and Calendar function Alerts notification (future release) Air conditioning malfunction alerts Connectivity monitoring and alerts History (future release) Specifications Specifications FJRCWIFI UTYVTGX UTYVTGXV Dimensions (H x W x D) () Power Supply polar 3wire DC2V nonpolar 2wire DC2V V 50/60Hz, Single phase Weight (g) Input power (W) Max..2 Max. 3 Dimensions (H x W x D) () Weight (g) 250,00 0

57 SU MO TU WE TH FR SA Convertor / Adaptor UTYVGGXZ Max. controllable 6 single indoor units Max. controllable 4 Group Remote Controllers UTYTEKX Air conditioner switching can be controlled by connecting other sensor switches This Network Convertor is to be used for connecting single split system or Group Remote Controller (UTYCGGY / UTYCGGG) with the VRF network system. Please select the function by switching the dip switch during the installation. In combination with a field supply CardKey Switch or other sensor, the External Switch Controller allows control of the ON / OFF, Room temperature, Fan speed and Master control functions. This makes this product suitable for installations such as hotel rooms. Cardkey or other sensor switches are available as a field supplied parts. Installation example Electrical wiring Functions Used for connecting single split system Split type systems can be centrally controlled from Touch Panel Controller or System Controller through connection to the VRF's network convertor. On / Off Control, Master control, Room temperature and Fan speed setting via the Network Convertor are available. One Network Convertor can be used to connect and control up to 6 single units. RB Unit Network Convertor Single Split Group of Single Split Auto mode operation, which switches the cooling and the heating automatically, is enabled by using the sensor switch and External Switch Controller. Note: All indoor units will operate in the same mode. T = ON, T2 = OFF Sensor SW (Field supplied) To individual dry contact External Switch Controller (UTYTEKX) Room temp. T T2 Time Note. Please choose a thermosensor switch which can be set up for T and T2. Note 2. The remote controller's operation is prior to the auto mode operation. Cardkey Indoor Unit 2 3 E COM SW SW2 Remote External Controller Line input Sensor SW Indoor External Switch Controller Unit 2 3 E COM SW SW2 Remote External Controller Line input External Switch Controller Cardkey (Field supplied) Sensor SW (Field supplied) USB Adaptor VRF network system System Controller Big Multi Please consult your distributor for connectable split type air conditioner. Up to 00 Network Convertors may be connected in single VRF network system. One Network Convertor is considered as a single refrigerant system, irrespective of the number of connected single models. UTYVSGXZ Used for connecting Group Remote Controller 4 Group Remote Controllers can be connected to a single Network Convertor (UTYVGGXZ). RB Unit Group Remote Controller UTYCGGY UTYCGGG Transmission Line length can be extended up to 3,600m with multiple Signal Amplifiers. Up to 40 signal amplifiers can be installed in a VRF network system. A signal amplifier is required, () When the total wiring length of the transmission line exceeds 500m. (2) When the total number of units on the transmission line exceeds. Installation example Network Convertor B VRF network system * 2 refrigerant circuits can be covered by a single Network Convertor (UTYVGGXZ). Up to a total of 6 Network Convertors (UTYVGGXZ) and System Controller adaptors can be connected in a single VRF network system. A D C Signal Amplifier Specifications Specifications UTYVGGXZ UTYTEKX UTYVSGXZ Power Supply 2040V 50/60Hz, Single phase Power Supply DC 2V Power Supply 2040V 50/60Hz, Single phase Power Consumption (W) 8.5 Dimensions (H x W x D) () 20 x 75 x Power Consumption (W) 4.5 Dimensions (H x W x D) () 67 x 288 x 2 Weight (g) 00 Dimensions (H x W x D) () 67 x 288 x 2 Weight (g),500 DC2V is supplied by the indoor unit. Weight (g),

58 Service & Maintenance Tool UTYASGX Extensive monitoring and analysis functions for installation and maintenance. Software Operation status can be checked and analyzed to detect even the small abnormalities. Data collected and stored on site can be checked later, offline, offsite for more detail analysis. One VRF network system with maximum number of up to 400 units can be monitored and controlled. Operation status and various sensor information can be monitored and checked real time in the form of list, refrigerant circuit diagram, graphs as well. Simple operation control functions are useful during maintenance. The recent error history can be retrieved from units on demand to perform analysis on the cause of the error, after connecting Service Tool to the VRF network system. Coissioning tool supports test runs, data storage for each unit and saving of data as CSV files, which may be formatted to create coissioning report. Connectable to any point of transmission line with USB adaptor * (field supplied) Connection between VRF network system to personal computer is possible via small U0 USB interface. However, both U0 USB interface & personal computer are field supplied items. 4 advanced functions are available for the VRII series for through servicing and through shooting. The operating state (Solenoid valve) of RB unit can be checked. * : Service Tool (UTYASGX) will only support USB type network adaptor and will not support transmission adaptor of the traditional type(utrytma) Max. Monitor 00 Outdoor units Max. Monitor and control 400 Indoor units 5) Error History Displays the error information for each unit. The error information can sequentially be displayed up to 50 items as they occur starting with the latest error. 7) Coissioning Tool Test run coands can be executed with this tool. During test running, the outdoor unit / indoor unit sensor data can be saved (coissioning log data). After the end of test running, this data can be exported in CSV file format. 9) Remote Setting * Function (Field) Setting for indoor unit is realized remotely 6) Remote File Download Operation and error history data can be downloaded. Only the required data may be downloaded specifying the refrigerant system, unit and time range. 8) Network Topology Analyzer * A list of units connected to the VRF system network is displayed in network segments in tree form. 0) System Time Setting * An arbitrary time is set for all the remote controllers within the system. ) Central Release * 2) Model Name Writer * Wiring connection The operation setting restriction function of the indoor units set from the controller can be forcibly released.(remote controller inhibit, temperature upper/lower limit setting) An arbitrary model name can be written to the target unit. Transmission line RB Unit Indoor unit USB adaptor (Field supplied) (Field supplied) 3) Error Memory Reader * When an error occurs at an outdoor unit, the operation data records before the error are acquired over a network and saved to a CSV file. 4) Time Guard Information * Reference data for judging the maintenance period of indoor and outdoor units (compressor,fan, etc. integrated time) is output to a CSV file. Indoor unit Easy to carry out with USB adaptor Note: To perform "Error Memory Reading", Service Tool and the corresponding outdoor unit must be connected directly with each other. Refer to the Operation Manual of the Service Tool for detail. *: Supported by Ver.. or later *USB Adaptor is U0 USB Network interface of Echelon Corporation. Functions ) System List Displays the overall operation status of all or specified units in the system in a list form. 3) Equipment Detail (List) Displays the detail information for sensor values, electrical components etc. of units in a specified refrigerant system in list form. The information here can be used along with the detail information in diagram form, to check the operation status of units and make detail analysis on the cause, in case an error occurs. 2) Equipment Detail (Diagram) Displays the detail information for sensor values, electrical components etc. for the specified units in schematic. The information here can be used along with the detail information in list form, to check the operation status of units and make detail analysis on the cause, in case an error occurs. 4) Operation History The indoor units or outdoor unit operation history can be recorded. The displayed operation history can be printed out and saved to a CSV file. Personal computer system requirements Operating system CPU Memory HDD Display Interface Software Optical drive <Packing list> Name and shape DVDROM WibuKey (Software protection key) Quantity GHz or higher GB or more (for Windows Vista, Windows 7 [32bit], Windows 8. [32bit], and Windows 0 [32bit]) 2 GB or more (for Windows 7 [bit], Windows 8. [bit], and Windows 0 [bit]) 0 GB or more of free space 024 x 768 or higher resolution 2 USB ports USB port is required for WibuKey connection USB port is required for Echelon U0 USB Network Interface Internet Explorer 8, 9, 0 or / Adobe Reader 9.0 or later DVDROM drive UTYASGX Microsoft Windows Vista Home Premium (32bit) SP2, Windows Vista Business (32bit) SP2 Microsoft Windows 7 Professional (32bit or bit) SP Microsoft Windows 8. Pro (32bit or bit) Microsoft Windows 0 Pro (32bit or bit) Application Includes the software and manuals Software protection key to be connected to USB port on the Service Toolinstalled PC. These products runs only on a PC with WibuKey. Personal computer that satisfies the following system requirements Echelon U0 USB Network Interface TP/FT0 Channel (Model number: 7500R) (Required for each VRF Network.) 4 5

59 Service & Maintenance Tool UTYAMGX Product features Software Troubleshooting is performed by monitoring each unit remotely during periodical system checks offsite. Operation status can be checked and analyzed to detect even the smallest abnormalities. Four VRF network systems each with 400 units, with maximum number of up to,600 units can be monitored and controlled. Operation status and various sensor information can be monitored and checked real time in the form of list, refrigerant circuit diagram, and graphs as well. The monitoring data in a remote side can be optionally downloaded. And, this data can be displayed in offline mode of the Service Tool. Error notification can be automatically transmitted to several locations using the internet *. Monitoring side computer is not required to install special software, requires only general web browser. Connectable to any point of transmission line with U0 USB interface *2 (field supplied) Connection between VRF network system to personal computer is possible via small U0 USB interface. However, both U0 USB interface & personal computer are field supplied items. The operating state (Solenoid valve) of RB unit can be checked. * : USB of internet mail system required. * 2: Web Monitoring Tool (UTYAMGX) will only support USB type network adaptor and will not support transmission adaptor of the traditional type (UTRYTMA). VRF network systems can be supported 4 Max. Monitor 400 Outdoor units Max. Monitor and control,600 Indoor unit can be monitored COMPARISON TABLE No. Item Interchangeability of equipment 2 Indication of equipment list 3 Operation control 4 Indication of refrigerant circuit diagram 5 Coissioning tool 6 Monitoring of equipment information 7 Monitoring of operating condition 8 Monitoring of sensor data 9 Storage and CSV output of operating history (sensor data) 0 Indication of trend graph Printing of trend graph 2 Monitoring and screen display of abnormalities 3 automatic transmission of abnormalities 4 Setting for user level Service Tool UTYASGX Web Monitoring Tool UTYAMGX VRF network system Side * Monitoring Side 5 Network Topology Analyzer * Web Monitoring System 6 Remote Setting * 7 System Time Setting * Monitoring Side VRF Network System Side 8 Central Release * 9 Model Name Writer * Outdoor unit 20 Error Memory Reader * 2 Time Guard Information * Transmission line *: Supported by Ver.. or later *: it is available only during a connection to the Internet. Web Monitoring Tool Internet or Public Telephone Line System components Monitoring Side Personal Computer (Field Supplied) Internet or Public Telephone Line Software (UTYAMGX) VRF Network System Side Personal Computer (Field Supplied) VRF Network System Software Protection Key USB adaptor (Field Supplied) RB Unit Support 4 VRF network systems USB adaptor (max. 4 adaptors per PC) permit, monitoring of up to,600 indoor units. Suitable for largescale buildings or hotels. VRF Network System Max. 400 Indoor unit USB adapter (Field supplied) Indoor unit USB adaptors VRF Network System 2 Max. 400 Indoor unit VRF Network System 3 Max. 400 Indoor unit RB Unit VRF Network System 4 Max. 400 Indoor unit Personal computer system requirements Operating system CPU Memory HDD Display Interface Software Optical drive <Packing list> Name and shape DVDROM Wibu Key (Software protection key) Quantity GHz or higher GB or more (for Windows Vista, Windows 7 [32bit], Windows 8. [32bit], and Windows 0 [32bit]) 2 GB or more (for Windows 7 [bit], Windows 8. [bit], and Windows 0 [bit]) 40 GB or more of free space 024 x 768 or higher resolution Ethernet port (for getting access to the Internet using LAN) or Modem (for getting access to the Internet using Public Telephone Line) USB ports (Maximum of 5 ports) USB port is required for WibuKey connection Maximum of 4 USB ports are required for Echelon U0 USB Network Interface * Maximum number of required USB ports depends on the applicable system configurations. Internet Explorer 8, 9, 0 or / Adobe Reader 9.0 or later DVDROM drive UTYAMGX Microsoft Windows Vista Home Premium (32bit) SP2, Windows Vista Business (32bit) SP2 Microsoft Windows 7 Professional (32bit or bit) SP Microsoft Windows 8. Pro (32bit or bit) Microsoft Windows 0 Pro (32bit or bit) Application Includes the software and manuals Software protection key to be connected to USB port on the Service Toolinstalled PC. These products runs only on a PC with WibuKey. Personal computer that satisfies the following system requirements Echelon U0 USB Network Interface TP/FT0 Channel (Model number: 7500R) (Required for each VRF Network.) 6 7

60 Efficiency and low noise levels are achieved by using a highly efficient heat exchange process. A comfortable air conditioned space is achieved by conveniently selecting whether to use heat exchange or normal ventilation setting, according to the requirements of the conditioned space. 8 9

61 Ventilation Energy efficiency and ecology Slim shape and easier installation Models UTZBD025B UTZBD035B UTZBD050B UTZBD0B UTZBD00B Energy recovery ventilator unit offers maximum comfort and greater energy savings. UTZBD025BB UTZBD035B UTZBD050B Energy consumption is dramatically reduced by using a counterflow heatexchange element. Air conditioning load is reduced by approximately 20%, resulting in significant energy savings. Recovers up to 77% of the heat in the outgoing air. Features of heat exchange element 20% Energy saving With the crossflow element, air moves in a straight line across the element. With the counterflow element, air flows through the element for a longer time (longer distance),so the heatexchange effect remains unchanged. Counterflow heat exchange element used for reduced noise and slier, more compact body yshape. Height 270 UTZBD025B Height 37 UTZBD035B/BD050B Height 388 UTZBD0B/BD00B UTZBD0B UTZBD00B Other element (Crossflow element) Fujitsu element (Counterflow element) Reverse mountable direct air supply / exhaust system Adoption of straight air supply / exhaust system: Duct design is simplified because the air supply / exhaust ducts are straight. Heat exchange ventilation and normal ventilation Heat exchange ventilation When a room is cooled or heated, the exhausted cooling / heating energy is recovered by heatexchange ventilation. Normal ventilation The operation is used during periods when the room space requires no cooling or heating effect, i.e. when there is minimal temperature difference between the indoor and outdoor environments. Adopts a highly efficient counterflow heat exchange element Exhaust air Outside air Room air Supply air Heat exchanger Quiet operation Significantly reducing low pressure loss and noise allows lownoise operation. Extended range of an external static pressure An external static pressure is improved by adopting a powerful fan motor. This allows for application in a wide variety building. Since each unit can be mounted in reverse position, only one inspection hole is needed for two units: Two units can share one inspection hole so duct work is easier and more flexible. Room air Straight unit Exhaust air Supply air Inspection cover Inspection hatch Outside air Room air Reverse mounted unit Exhaust air Specifications Dimensions (Unit : ) Rated flow rate 250 m 3 /h 350 m 3 /h 500 m 3 /h 0 m 3 /h 000 m 3 /h Models: UTZBD025B / UTZBD035B / UTZBD050B / UTZBD0B / UTZBD00B Model No. UTZBD025B UTZBD035B UTZBD050B UTZBD0B UTZBD00B Power source HEAT EXCHANGE VENTILATION NORMAL VENTILATION Input power Air flow rate External static pressure Temperature Exchange Efficiency Energy Exchange Efficiency Energy Exchange Efficiency Heat pump Sound pressure level Input power Air flow rate External static pressure Sound pressure level Dimensions (W D H) Weight Outlet duct diameter Operation range Maximum humidity Extra high / / Low Extra high / / Low Extra high / / Low Extra high / / Low Extra high / / Low Extra high / / Low Extra high / / Low Extra high / / Low Extra high / / Low Extra high / / Low Extra high / / Low W m 3 /h Pa % % % db* W m 3 /h Pa db* kg C % * The noise level must be measured.5 m below the centre of the unit. 28 / 23 / / 250 / / 95 / / 75 / / 63 / 70 / 70 / /.5 / / 23 / / 250 / / 95 / /.5 / x 599 x ~ / 85 / / 350 / / 60 / / 75 / / 66 / 7 69 / 69 / / 3 / / 85 / / 350 / / 60 / / 3 / x 4 x ~ V, 50Hz 289 / 225 / / 500 / / 60 / / 75 / / 62 / 67 / 67 / / 35.5 / / 225 / / 500 / / 60 / / 38 / x 904 x ~ / 378 / / 0 / 6 40 / 0 / / 75 / 76 / / 68 7 / 7 / / 37 / / 378 / / 0 / 6 40 / 0 / / 37 / x 884 x ~ / 432 / / 000 / / / / 75 / 79 / / 70 7 / 7 / / 37.5 / / 432 / / 000 / / / / 39.5 / x 34 x ~ Maintenance space Maintenance opening A B C D E F G H I J K L M N O UTZBD025B UTZBD035B UTZBD050B UTZBD0B UTZBD00B

62 Ventilation Models ARXH054GTAH ARXH072GTAH ARXH096GTAH The heat pump method efficiently processes the outdoor air for cooling and heating and supplies 00% fresh air into a room. Production by order ARXH054GTAH ARXH072GTAH energy savings and flexible duct design by using DC motor Greatly reduces electricity consumption by adopting permanent magnet compared to when using an AC motor. 054 / 072 type 096 type Compared with AC motor, changing the speed makes it possible to respond flexibly to the external static pressure from 50 Pa to 240 Pa. Even if damper equipment is not used, static pressure can be adjusted and duct design is easy. Static pressure can be set easily using wired remote controller. DC Motor (When external static pressure is small) Low speed 50 to 240 Pa (096 type) speed (When external static pressure is large) Various Controller Supplied variety of controllers as options, such as individual controller, central controller, and building management controller. Individual Controller Wireless Remote Controller Central Controller Simple Remote Controller Wired Remote Controller Wired Remote Controller (Touch Panel) ARXH096GTAH AC Motor speed (Constant) speed (Constant) One VRF system can provide air conditioning and air supply at the same time. Outdoor Air Unit can be connected in a same VRF* system as one of indoor unit series and can create fresh and comfortable air supply together from our high advanced technology. *. Connectable VRF series:jiis, JIII, VII, VRII In JIII series alone, OAU is prohibit to connect under the ambient temperature of 40 C or higher. Outdoor Air Unit Fan Heat Exchanger Outdoor Air Unit VRF system Indoor unit Fresh Air Duct Indoor unit Wired R.C. Wired R.C. Wired R.C. Fresh Air * Make sure the connected capacity is within the range of 50% to 00% of the outdoor unit capacity. In addition, if there are mixed connections with indoor units, make the Outdoor Air Unit connection capacity % or less of the outdoor unit capacity. Damper opening small (Field supplied) Top class compact design Top class lightweight compact design at just 425 in height, 55 kg in weight for ARXH072 type. This unit can be installed easily even at narrow space. 55kg (072 type) 367 (ARXH072 type) Damper opening large (Field supplied) Group Remote Controller Central Remote Controller Touch Panel Controller * The temperature setting is discharged air temperature setting. The air volume is set to a constant speed. System Controller System Controller Lite (Software) Specifications Rated flow rate 000 m 3 /h 500 m 3 /h 2000 m 3 /h (Tentative) Dimensions (Unit : ) Models: ARXH054GTAH / ARXH072GTAH / ARXH096GTAH Model No. ARXH054GTAH ARXH072GTAH ARXH096GTAH ARXH054GTAH Power source Capacity Input Power / Airflow Rate Static Pressure Standard (range) Sound Pressure Level Dimensions (H x W x D) Weight Connection Pipe Diameter (Small / Large) Operation Range Refrigerant Note : Specifications are based on the following conditions. : Outdoor temperature of 33 CDB / 28 CWB. : Outdoor temperature of 0 CDB / 2.9 CWB. Pipe length : 7.5 m Voltage : 2 [V]. W m 3 /h Pa db (A) kg ºCDB 2// ,0 85 (5085) , Ø9.52/Ø 5 to 43 7 to 2 R40A 2// ,6 200 (50200) , Ø2.70/Ø to 43 7 to 2 R40A 2// , (50240) , Ø2.70/Ø to 43 7 to 2 R40A Side view (L) (Drain hose) ARXH072GTAH Top view Front view Main drain port Safety drain port Side view (R) Main drain port ARXH096GTAH Main drain port Safety drain port Safety drain port Side view (R) Side view (R) Side view (L) Top view Side view (L) Top view (Drain hose) (Drain hose) 22 Front view Front view 23

63 Ventilation Models Control unit UTYVDGX EEV unit UTPVXA UTPVX60A UTPVX90A These kits enable other manufacturers air handling units (AHU) and fan coil units (FCU) to be incorporated into a Fujitsu VRF system or, be connected to a dedicated Fujitsu VRF outdoor unit as a : system to control outside air ventilation (AHU) or room temperature (FCU). Multiple temperature sensors optimally control the air handling unit and fan coil unit. Control unit UTYVDGX EEV unit EEV unit EEV unit UTPVXA UTPVX60A UTPVX90A Functions Suary Inputs ON/OFF Setting temperature Capacity demand / operation mode Fault information Installation Limitation Outputs ON/OFF indication Fan ON/OFF indication Thermo ON/OFF indication Defrost indication Fault indication Connectable VRF series : JIIS, JIII, VII, VRII Connectable DXKit system capacity range : 50 to 00% of the outdoor unit capacity Connectable DXKit system capacity range with indoor units : % or less of the outdoor unit capacity Max. wiring length from control unit : 0 m Max. piping length between EEV unit and indoor unit : 5 m Outdoor installation : Control unit (IP54 class) and EEV unit can be installed at an outdoor space. Connectable capacity Single connection DXKIt Air Handling Unit 50%00% of outdoor unit capacity Modbus Control Possible to control via a Modbus enabled BMS by using optional interface. Mixed connection DXKIt Air Handling Unit Within % of total capacity DXKit AHU Thermistor When connecting to an air handling unit, the supply air temperature is controlled by the discharge sensor. Arrangement as part of a VRF system Indoor unit Transmission line [For 2EEV units connection (option)] Separation Tube : UTPLXA Piping and wiring length Air Handling Unit EEV unit 50%00% of outdoor unit capacity VRF system Max. piping length 5 m Max. wiring length 0 m Control unit DXKit FCU Thermistor When connecting to a fan coil unit, the room temperature is controlled by the return air temperature sensor. Air Handling Unit Thermistor DXKit Control unit EEV unit Wired R.C. Specifications Max. wiring length 0 m EEV unit UTPVXA UTPVX60A UTPVX90A UTPVX90A 2 Power source V/Ø/Hz 2 / / 50 Connectable capacity class Supports a wide range of capacity classes 2 EEV units can be connected in parallel and up to 20 HP (50 ) large capacity units. (Separation Tube of UTPLXA is required.) Connectable capacity range: 5 to 50 Piping EEV unit EEV unit Wiring Control unit AHU or FCU (40 50 class) A variety of controls to match the application Central control using our VRF controllers or central management controllers Transmission line VRF Controller Interface (Option) Modbus network (Future release) DXKit Central control from external controllers Transmission line DXKit External I/O DDC* 3rd party Controller External I/O Thermistor Thermistor External I/O AHU or FCU AHU or FCU *DDC=Direct Digital Controller Capacity Airflow Rate(Reference value) Dimensions (H W D) Weight Connection pipe diameter(liquid) Control unit Power source Dimensions (H W D) Weight m 3 /h kg V/Ø/Hz kg 5.6 (5.5.9) 6.3 (5.76.7), (6.07.) 7. (6.88.0),200 8 (7.29.0) 9 (8.0.0),520 0 (9..).2 (0.2.4) Note : Specifications are based on the following conditions. : Indoor temperature of 27 CDB / 9 CWB, and outdoor temperature of 35 CDB / 24 CWB. : Indoor temperature of 20 CDB / (5 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m Voltage : 2 [V]., (.23.2) 4 (2.55.0) 2,000 4 (3.38.0) 6 (5.20.0) 2, (8.23.7) 25 ( ) 3, (23.8.0) 28 ( ) 4, ( ) 45 (3.9.9) 6, ( ) 56.5 ( ) 8, ( ) Ø9.52 Ø2.70 UTYVDGX 2 / /

64 Models UTDGXTAW UTDGXTBW UTDGXTCW Simple flat Auto Louver will provide comfort airflow and harmonize with luxury interior. Closed louver Opened louver Flexible Control Operation with indoor unit Auto Louver can be operated by synchronizing remote controller of indoor unit. UP and Down auto swing Auto airflow direction and auto swing 4 steps selectable Autoclosing louver When operation of indoor unit is stopped, the louver will automatically close. Auto Louver Grille Dimensions W2 W H Fitting Flame Grille H2 D D2 Duct type Unit: Model Name W W2 H H2 D D2 UTDGXTAW UTDGXTBW Wired Remote Controller Wireles Remote Controller UTDGXTCW,083,045 Specifications Applicable Indoor Unit Power Supply Fixing of Auto Louver Grille Extension Square Duct Limit UTDGXTAW UTDGXTBW UTDGXTCW ARXD04/07/09/2/4GALH ARXD8GALH ARXD24GALH ARXK07/09/2/4GCLH ARXK8GCLH ARXK24GCLH Connecting with Control box of indoor unit Screw xing to Flange or Square Duct.0m (Max. duct length between indoor unit and Grille) Net Dimension (H x W x D) (inch) x683x(84+9) [73/32x267/8x(35/6+/32)] x883x(84+9) [73/32x343/4x(35/6+/32)] x083x(84+9) [73/32x425/8x(35/6+/32)] Weight Net Gross kg (lb.) 2.0 (4.4) 3.0 (6.7) 2.5 (5.6) 3.5 (7.8) 3.0 (6.7) 4.0 (8.9) Color White Louver Motor Stepping Motor Accessories Fitting Flame, etc. Operation range C ( F) % RH 8 to 32 ( to 90) % or less C ( F) 6 to (60 to 88) *: The Auto Louver Grille Kit can also be installed to ARXD07/09/2/4/8/24LATH revision code B models. Please refer to the Design & Technical manual for revision code " details

65 Option Connection Units Specifications Separation Tube Separation Tube UTPAX054A UTPAX090A UTPAXA UTPAX567A Gas Pipe Gas Pipe Gas Pipe Gas Pipe Total cooling capacity of indoor unit () 9.6 or less 28.0 or less 28. to or more UTPBX090A UTPBXA UTPBX567A Total cooling capacity of indoor unit () 28.0 or less 28. to or more Liquid Pipe Liquid Pipe Liquid Pipe Liquid Pipe Header Suction Gas Pipe Discharge Gas Pipe UTPAX054A Suction Gas Pipe Discharge Gas Pipe UTPAX090A Suction Gas Pipe Discharge Gas Pipe UTPAXA For DXKit UTPAX567A Total cooling capacity of indoor unit () Total cooling capacity of indoor unit () 36 Branches 38 Branches 36 Branches 38 Branches UTRH0906L UTRH0908L 28.0 or less UTPJ0906A UTPJ0908A 28.0 or less UTRH6L UTRH8L 28. to 56.0 UTPJ6A UTPJ8A 28. to 56.0 Liquid Pipe UTPBX090A Liquid Pipe UTPBXA Liquid Pipe UTPBX567A UTPLXA Outdoor unit Branch kit UTPCX567A (for VII) UTPDX567A (for VRII) Header Outdoor Unit Branch Kit Number of Outdoor unit 2 outdoor units 3 outdoor units 2 Gas Pipe Gas Pipe Gas Pipe EV Kit UTREV09XB UTREV4XB Liquid Pipe Liquid Pipe Liquid Pipe Application Model ASYE04GACH ASYE07GACH ASYE09GACH ASYE2GACH ASYE4GACH UTRH0906L / UTRH6L UTRH0908L / UTRH8L UTPCX567A RB Unit Type Single type Multi type Suction Gas Pipe Suction Gas Pipe Suction Gas Pipe UTPRX0AH UTPRX0BH UTPRX0CH UTPRX04BH Power source Single phase 2V, 50Hz Discharge Gas Pipe Discharge Gas Pipe Discharge Gas Pipe Input power Number of branches W Liquid Pipe UTPJ0906A / UTPJ6A Liquid Pipe UTPJ0908A / UTPJ8A Liquid Pipe UTPDX567A Maximum capacity of connectable indoor units(q) Maximum capacity of connectable indoor units per branch(q) Maximum number of connectable indoor units per branch Q 8.0 Q Q 8.0 Q Q 28.0 Q Q 56.0 * Q EV Kit For Compact Wall Mounted type RB Unit Single type Multi type Dimensions (H W D) *: In case of two RB units connected in series ( total 8branches ), maximum capacity of connectable indoor units is up to Model code 09 : UTREV09XB Model code 2 : UTREV4XB UTPRX0AH / UTPRX0BH / UTPRX0CH UTPRX04BH 28 29

66 Option Controllers For Individual Control Convertors / Adaptors For External device Wired Remote Controller (Touch Panel ) UTYRNRYZ N E W Wired Remote Controller UTYRLRY Simple Remote Controller UTYRSKY With operation mode BACnet Gateway UTYABGX Software Network Convertor for LONWORKS UTYVLGX MODBUS Convertor for VRF UTYVMGX N E W DVDROM (Software) Software Protection Key Simple Remote Controller UTYRHKY Without operation mode Wireless Remote Controller UTYLNHY IR Receiver Unit UTBYWC For All Duct types except Large Airflow Duct MODBUS Interface FJRCMBS KNX Interface FJRCKNXi Wireless LAN Interface FJRCWIFI IR Receiver Unit UTYLRHYB For System expansion For Cassette type Network Convertor for single split UTYVTGX N E W DC power supply type Network Convertor for single split UTYVTGXV N E W AC power supply type Network Convertor for Group Remote Controller UTYVGGXZ For Centralized Control Group Remote Controller Central Remote Controller Touch Panel Controller External Switch Controller UTYTEKX Signal Amplifier UTYVSGXZ UTYCGGY UTYDCGY UTYDTGYZ N E W Option UTYPTGXA Panels System Controller Lite Software System Controller Software For Cassette type UTYALGX UTYAPGX Cassette Grille Cassette Grille UTGUFYCW UTGUGYAW Option Option For Compact Cassette type For Cassette type UTYPLGXA UTYPLGXR UTYPLGXE UTYPEGX 3

67 Option Others Counication system: External Connect Kit For Duct type For Indoor unit For Outdoor unit Flange (Round) UTDRF204 Flange (Square) UTDSF045T Remote Sensor Unit UTYXSZX UTYXWZXZ7 UTYXWZXZD UTYXWZXZ6 For Medium Static Pressure Duct type / Ceiling type For Medium Static Pressure Duct type For All Duct type UTYXWZXZB UTYXWZXZE UTYXWZXZ9 New amenity space can be offered by installing the Remote sensor. UTYXWZXZC UTYXWZXZF For RB unit UTYXWZXZ6 UTYXWZXZB For Central Remote Controller UTYXWZXZ7 UTYXWZXZ8 UTYXWZXZA For Touch Panel Controller UTYXWZXZA LongLife Filter UTDLF25NA For Medium Static Pressure Duct type UTDLF60KA For Static Pressure Duct type Auto Louver Grille Kit UTDGXTAW (for ARXD04/07/09/2/4GALH, ARXK07/09/2/4GCLH) UTDGXTBW (for ARXD8GALH, ARXK8GCLH) UTDGXTCW (for ARXD24GALH, ARXK24GCLH) For Slim Duct type / Mini Duct type Drain Pump Unit UTZPXBBA For Low Static Pressure Duct type UTZPXNBA For Medium Static Pressure Duct type Function list Controller Other For Cassette type Operation / Stop Indoor unit UTYXWZXZD UTYXWZXZB Outdoor unit Central Remote Controller Touch Panel Controller RB Unit Wide Panel UTGAKXAW For Cassette type Panel Spacer UTGBGYAW For Cassette type Insulation Kit for Humidity UTZKXRA UTZKXGC For Cassette type For Compact Cassette type All On / All Off Batch Stop UTYXWZXZ6 UTYXWZXZ7 UTYXWZXZ8 *3 *3 Indoor unit 950 Insulation Kit Forced Stop UTYXWZXZD UTYXWZXZB Panel () Panel spacer 50 Output Input Emergency Stop Forced Thermostat off Low Noise Mode Operation / Priority "Outdoor Unit Operation Peak Control" "Power Usage Information from Electricity Meter" Operation Status Error Status Indoor Unit Fun Operation Status Auxiliary Heater Output UTYXWZXZD UTYXWZXZB UTYXWZXZE UTYXWZXZ7 UTYXWZXZC UTYXWZXZC UTYXWZXZC UTYXWZXZC *2 UTYXWZXZ6 UTYXWZXZ6 * UTYXWZXZ6 UTYXWZXZ6 UTYXWZXZF UTYXWZXZ6 UTYXWZXZ6 UTYXWZXZ7 UTYXWZXZ8 UTYXWZXZA UTYXWZXZA *3 *3 *3 *3 UTYXWZXZA UTYXWZXZA UTYXWZXZ6 UTYXWZXZB Fresh Air Intake Kit UTZVXAA For Compact Cassette type For Ceiling type Drain Pump Unit UTRDPB24T For Ceiling type UTZVXRA For Cassette type Air Outlet Shutter Plate UTRYDZB For Compact Cassette type Shuts the air outlet when only using as 3 blow out. Air Outlet Shutter Plate UTRYDZK For Cassette type Shuts the air outlet when only using as 3 blow out. Base Heater UTYXWZXZ9 *. Heat Pump type only *2. Duct type only *3. Touch Panel Controller has these functions for Dry contact and Apply voltage, however, above External Connect Kit is not necessary because Touch Panel Controller has an external input terminal block. : Dry Contact : Apply Voltage 32 33

68 Reference There are many applications for Airstage VRF systems including such markets as education, healthcare,hospitality, utilities, office buildings, apartment buildings, condominiums, and restaurants. Note: VRF Heat Recovery system provides simultaneous and. System operates both mode and mode. Educational and Religious Facilities Medical and Healthcare Facilities In a school, an investment in VRF is an investment in your counity. VRF is more efficient than conventional systems, providing financial savings to the school for many years. Also, a quiet VRF system creates a much better learning environment for students. VRF gives each patient individual control of their room temperature. Central control ensures that air conditioning is only delivered to rooms that are occupied. INDIVIDUAL CONTROL VRF gives each patient or each room individual control of their room temperature. CLEAN AIR VRF systems can use ductless indoor units reducing the time and expense of maintaining a HVAC system and eliminating the risk of ductborne molds and bacteria. CENTRAL CONTROL Powerful central control ensures that heating and cooling are delivered to rooms that are occupied. This provides enormous savings for facilities with revolving occupancy. MAINTENANCE Since each refrigerant circuit has the ability to operate independently, a properly designed VRF system can add a layer of security to a HVAC system. If an individual unit needs to be shut down for repairs, the rest of the system can operate normally. FRESH AIR VRF systems can be integrated with fresh air systems to ensure that air quality meets the needs of the occupants. VRF provides the most comfortable environment for all occupants. HEALTHIER FACILITY VRF systems can be integrated with fresh air systems to ensure that air quality meets the needs of the teachers and students. CENTRAL CONTROL Powerful central control can monitor and control individual schools, or an entire college campus, from a single location. ZONING Save energy by heating and cooling the classrooms that are occupied. Set temperature can preprograed to meet the energy budget for the school district. COMFORT VRF helps achieve a healthier, quieter, more comfortable and productive learning environment

69 Reference MultiTenant Dwellings Office Buildings and Retail Spaces VRF improves the quality of multitenant buildings while reducing tenant complaints. quality VRF systems let owners save on energy costs and reduced maintenance costs. With VRF, each tenant has individual control over the temperature setting for the comfort of their home. VRF provides a comfortable work environment for all employees. Zoning ensures that energy is only used to cool/heat occupied offices. Quiet indoor units and precise temperature control creates the most comfortable and productive work environment. 36 QUALITY By delivering quiet, efficient heating and cooling, VRF improves the quality of multitenant buildings and reduces tenant complaints. ENERGY SAVINGS Efficient VRF systems reduce the total energy costs for buildings over most other options. quality systems reduce maintenance and service costs. INDIVIDUAL BILLING Using the Energy Charge Apportionment feature, landlords can easily bill each tenant for the percentage of total energy the individual tenant consumes. INDIVIDUAL COMFORT With VRF, each tenant can have their own controller to set their room temperature for their maximum comfort. CONVENIENT CENTRAL CONTROL Landlord can monitor and control all indoor units from a central location. Landlord can even troubleshoot or solve tenant complaints remotely. QUIET Indoor units ensures a quiet, comfortable living environment for all tenants. QUIET Indoor units and outdoor units creates a pleasant work environment and reduces noise complaints. ZONING Save energy by heating and cooling occupied offices. No more hot/cold calls since each zone or tenant has individual control of the set temperature.. CONTROL Powerful controls options can manage and monitor entire building from a single location. EASE OF INSTALLATION Can be installed in occupied office spaces with minimal disruption to occupants. Can even be installed without disrupting the existing HVAC system. FLEXIBLE As tenants and office configurations change, VRF system configurations can also be modified (within original design constraints) to meet the needs of new tenants. COMFORT VRF provides a comfortable work environment for all employees. Quiet indoor units and precise temperature control creates the most comfortable and productive work environment. 37

70 ISO 900 ISO 400 Certified number: Certified number: /0 Fujitsu General (Thailand) Co., Ltd. ISO 900 ISO 400 Certified number: Certified number: CNBJ353UK Fujitsu General (Shanghai) Co., Ltd. ISO 900 ISO 400 Certified number: 594Q00R4M Certified number: 592E0022R3M Fujitsu General Central Airconditioner (Wuxi) Co., Ltd. is a worldwide trademark of FUJITSU GENERAL LIMITED and is a registered trademark in Japan and other countries or areas. Specifications and design are subject to change without notice for future improvement. For further details, please check with our authorised dealer. iphone and ipad are trademarks of Apple Inc., registered in the U.S. and other countries. Other company and product names mentioned herein may be registered trademarks, trademarks or trade names of their respective owners. Actual products colors may be different from the colors shown in this printed material. Distributed by : Copyright Fujitsu General Limited. All rights reserved. 6EF004604E

Multi Air Conditioning System for Buildings

Multi Air Conditioning System for Buildings Multi Air Conditioning System for Buildings 6, Suenaga, Takatsuku, Kawasaki 238502, Japan http://www.fujitsugeneral.com/ ISO 900 ISO 400 ISO 900 ISO 400 Certified number : 0 00 89394 Certified number :

More information

1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/

1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/ 1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/ ISO 9001 ISO 14001 Certified number : 01 100 89394 Certified number : 01 104 9245101 Fujitsu General (Thailand) Co.,

More information

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy LG Air conditioning Company Multi V Water Ⅱ Air Conditioning Academy 1.1 What is Multi V Water II? High Performance Prospect rights Water pipe Refrigerant pipe Indoor unit Beautiful Exterior Convenience

More information

york air-conditioning products Residential & VRF News 2015

york air-conditioning products Residential & VRF News 2015 york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter

More information

Contents. Part 1 General Information... 1. Part 2 Outdoor Units... 9. Part 3 Installation... 50. Part 4 Troubleshooting 73

Contents. Part 1 General Information... 1. Part 2 Outdoor Units... 9. Part 3 Installation... 50. Part 4 Troubleshooting 73 MCAC-VTSM-2013-03 R410a Full DC Inverter Mini VRF Contents Part 1 General Information... 1 Part 2 Outdoor Units... 9 Part 3 Installation... 50 Part 4 Troubleshooting 73 Part 5 Control System... 100 Manufacture

More information

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient

More information

Inverter Air Conditioning for Light Commercial Use

Inverter Air Conditioning for Light Commercial Use Inverter Air Conditioning for Light Commercial Use 02 Cost Saving Comfort An efficient use of time 03 SDISuper Digital Inverter Very efficient energy consumption Keeps down operating costs Heater operation

More information

DUCTED AIR CONDITIONING SOLUTIONS

DUCTED AIR CONDITIONING SOLUTIONS DUCTED AIR CONDITIONING SOLUTIONS H I G H E N E R G Y E F F I C I E N C Y B A C K E D B Y A 5 Y E A R F U L L P A R T S & L A B O U R W A R R A N T Y DUCTED RANGE WHY CHOOSE FUJITSU? AUSTRALIA S FAVOURITE

More information

The ABC s of VRF: A Green HVAC Technology An Ideal Green School Solution. Presented by: Fujitsu General America, Inc.

The ABC s of VRF: A Green HVAC Technology An Ideal Green School Solution. Presented by: Fujitsu General America, Inc. The ABC s of VRF: A Green HVAC Technology An Ideal Green School Solution Presented by: Fujitsu General America, Inc. What to look for in a Green HVAC solution? What if your HVAC system could provide Individual

More information

FULL DC INVERTER SYSTEMS

FULL DC INVERTER SYSTEMS FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR DESIGN & FLEXIBLE COMBINATION commercial air conditioners SDV4 2011/2012 AIR CONDITIONING 1 WELCOME TO THE WORLD of SINCLAIR AIR CONDITIONERS Company operation

More information

NEW 3-PIPE ECOi MF2 SERIES

NEW 3-PIPE ECOi MF2 SERIES NEW 3-PIPE ECOi MF2 SERIES SIMULTANEOUS HEATING AND COOLING VRF SYSTEM Internet Control Ready INTERNET CONTROL NEW Energy Environmentally friendly refrigerant R410A Down to -20 ºC in heating mode OUTDOOR

More information

LG Electronics AE Company, Commercial Air Conditioning

LG Electronics AE Company, Commercial Air Conditioning www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,

More information

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE Hitachi Air Conditioning Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE Contents Page 04 Product Range 08-09 RAC Summit Wall Mounted 10 RAC Shirokuma Wall mounted 11 RAC S Series - Wall

More information

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

New Deluxe Wall Mounted Heat Pump Series EXTERIOS New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History

More information

Air Conditioning For Large Buildings

Air Conditioning For Large Buildings Air Conditioning For Large Buildings Index Introduction 3 Industry leading energy savings 6 New smart & sensitive VRF control 10 Industry leading layout flexibility 14 Other features 18 Outdoor units Outdoor

More information

1 4. 3 4-2 ABNORMAL OPERATION. 4-2-1 Error code Display. Specifics Error Code. Subsection Error Code. Subsection and Specifics Error code target

1 4. 3 4-2 ABNORMAL OPERATION. 4-2-1 Error code Display. Specifics Error Code. Subsection Error Code. Subsection and Specifics Error code target 4-2 ABNORMAL OPERATI 4-2-1 An is represented by 3 digit characters. The first 2 digit means the subsection, and the last 1 digit means the specifics. Ex.) Indoor unit Network communication Error Subsection

More information

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability PFD-P250VM-E PUHY-P250YJM-A(-BS) PUHY-P500YSJM-A(-BS) PQHY-P250YHM-A CLOSE CONTROL SYSTEM MITSUBISHI ELECTRIC s Close Control System (PFD series) is specifically designed for computer rooms, laboratories

More information

Multi Air Conditioning System for Buildings

Multi Air Conditioning System for Buildings TM Variable Refrigerant Flow System Multi Air Conditioning System for Buildings Large Capacity Multi VRF System DC Inverter Control Compressor Long Piping System Design High Efficiency Refrigerant R40A

More information

FTQ. Daikin Inverter Ducted Heat Pump

FTQ. Daikin Inverter Ducted Heat Pump FTQ Daikin Inverter Ducted Heat Pump A TRADITIONAL CENTRAL AIR SYSTEM MADE BETTER WITH DAIKIN CONSTANT COMFORT INVERTER TECHNOLOGY. The Daikin Inverter Ducted Heat Pump line is a cost effective alternative

More information

HP switch LP switch Discharge thermo Comp. Surface thermo

HP switch LP switch Discharge thermo Comp. Surface thermo 1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer

More information

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor

More information

Earth can hardly wait for a change in the atmosphere. Nor can we. By making air conditioning supremely energy-efficient, quiet, easy to install, and

Earth can hardly wait for a change in the atmosphere. Nor can we. By making air conditioning supremely energy-efficient, quiet, easy to install, and 1 Earth can hardly wait for a change in the atmosphere. Nor can we. By making air conditioning supremely energy-efficient, quiet, easy to install, and cost-effective, Toshiba aims at the heart of growing

More information

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t

More information

More than Air Conditioning. Catalogue 2004/2005. Air Conditioning Program R 407C R 410A

More than Air Conditioning. Catalogue 2004/2005. Air Conditioning Program R 407C R 410A More than Air Conditioning Catalogue 2004/2005 Air Conditioning Program R 407C R 410A MITSUBISHI ELECTRIC Air Conditioning Systems As one of the world s leading technology companies, MITSUBISHI ELECTRIC

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

FCQ. Roundflow Cassette Heat Pump or Cooling Only

FCQ. Roundflow Cassette Heat Pump or Cooling Only FCQ Roundflow Cassette Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FCQ roundflow cassette SkyAir systems are ideal for open plan applications where variances in temperature and airflow

More information

FTXS. Wall Mount Heat Pump or Cooling Only

FTXS. Wall Mount Heat Pump or Cooling Only FTXS Wall Mount Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FTXS SkyAir systems feature streamlined, wall mounted indoor units paired with quietly compact outdoor units. Available in both

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS

More information

For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System

For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System For Residential & Light Commercial Applications 4 Ton 8 Zone Multi Split Heat Pump System EXPERTISE AND INNOVATION The Super Multi PLUS Split System is the ultimate, flexible solution for individual zone

More information

FHQ. Ceiling Suspended Heat Pump or Cooling Only

FHQ. Ceiling Suspended Heat Pump or Cooling Only FHQ Ceiling Suspended Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FHQ ceiling suspended SkyAir systems are ideal for applications without false ceilings. Installed from the structure, this

More information

Air Conditioning for Small and Medium-size Buildings

Air Conditioning for Small and Medium-size Buildings Air Conditioning for Small and Medium-size Buildings Defining a HIGHER standard The all-new MiNi-SMMS air conditioner lineup lets you cool or warm as many as 12 *1 rooms with a single system. Outdoor units

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data O u t d o o r U n i t E E D E N 2-0 0 RX-JV Outdoor Unit RX-JV TABLE OF CONTENTS RX-JV Features............................................................. 2 2 Specifications.......................................................

More information

Appendix - Controllers 179

Appendix - Controllers 179 Version: 200703 Appendix - Controllers 179 -3- -4- -5- -6- -7- -8- 2. Specifications 2.1 Specifications for inverter units item Model AB182ACERA Function cooling heating Capacity kw 5.01.8--5.8 5.22.0---6.2

More information

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

Gree Solar Hybrid Hi Wall Inverter Air Conditioner Gree Solar Hybrid Hi Wall Inverter Air Conditioner Utilize the natural power of the sun to heat or cool your home. Find out more at www.greeonline.com Why Choose a Solar Hybrid Inverter? The new Gree Solar

More information

Commercial Gas Heat Pump - VRF

Commercial Gas Heat Pump - VRF SANYO GHP Introduction Commercial Gas Heat Pump - VRF 01.12.2011 Agenda 1. SANYO GHP History 2. SANYO GHP Range 3. GHP Market Position 4. 2-WAY 5. GHP Power 6. 3-WAY 7. EER/COP 8. Water Heat Exchanger

More information

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI R410A Models Indoor unit Outdoor unit AB*14LBAJ AB*18LBAJ AB*F14LAT

More information

KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle

KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle KSV70HRF RRP AUS $1,709.00 Split System Reverse Cycle air conditioner featuring inverter technology, clean front with LED display, Bio and active carbon filter, 2 way auto swing (up, down), remote (7.1kW

More information

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/ SERVICE MANUAL Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/ FS2MI-147HFD FS2MI-187HFD FS3MI-217HFD FS3MI-277HFD FS4MI-277HFD FS4MI-367HFD FS5MI-367HFD NOTE: Before servicing the

More information

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp

More information

ECO-AIR AIR CONDITIONING www.northamericanhvac.com

ECO-AIR AIR CONDITIONING www.northamericanhvac.com INDEX ACCESSORIES INSTALLATION... 3-7 LINE SETS... 3-7 GEOTHERMAL... 3-8 WIRING CABLE... 3-8 CIRCULATOR PUMPS (PRO-TECH MODEL)... 3-9 DC INVERTER SINGLE ZONE HEAT PUMP... 3-6 DC INVERTER TECHNOLOGY...

More information

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05 TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation

More information

FBQ. DC Duct Heat Pump or Cooling Only

FBQ. DC Duct Heat Pump or Cooling Only FBQ DC Duct Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FBQ DC Duct systems offer a powerful solution, compact in design and easily concealed in a ceiling. With both cooling only and heat

More information

Samsung Room Air Conditioning

Samsung Room Air Conditioning Samsung Room Air Conditioning Air Conditioning Solutions from a Trusted Brand At the heart of family living is the home, a place full of special moments and wonderful memories where families live and

More information

Pioneer in sustainability

Pioneer in sustainability Pioneer in sustainability Over 100 years ago Carrier helped pioneer a new industry, and in the last two decades we have pioneered environmentally sensitive products with a reduced impact on the environment.

More information

USER S MANUAL HSC-24A

USER S MANUAL HSC-24A AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL

More information

How To Make A High Efficiency Thermostat

How To Make A High Efficiency Thermostat Zoning with Variable Speed Mini-Split Systems Fujitsu Service Training Welcome - Thank you for attending Did you know? In 1940 only 42% of homes in the US had central heating In 1970 20% of homes had central

More information

2015 HVAC Excellence Educator Conference Variable Refrigerant Flow & Variable Refrigerant Temperature

2015 HVAC Excellence Educator Conference Variable Refrigerant Flow & Variable Refrigerant Temperature 2015 HVAC Excellence Educator Conference Variable Refrigerant Flow & Variable Refrigerant Temperature Slide 1 Residential Market Push for more efficiency Green Building Initiative R-22 & High Efficiency

More information

HVAC Systems: Overview

HVAC Systems: Overview HVAC Systems: Overview Michael J. Brandemuehl, Ph.D, P.E. University of Colorado Boulder, CO, USA Overview System Description Secondary HVAC Systems Air distribution Room diffusers and air terminals Duct

More information

AIR-CONDITIONER SPLIT TYPE

AIR-CONDITIONER SPLIT TYPE FILE NO. A08-016 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE RAS-M10PKVP-E, RAS-M13PKVP-E, RAS-M16PKVP-E, RAS-M18PKVP-E / RAS-M10PKVP-ND, RAS-M13PKVP-ND, RAS-M16PKVP-ND, RAS-M18PKVP-ND / RAS-3M26GAV-E1,

More information

-~ available. Power consumption during operation is substantially less than that of lower rated

-~ available. Power consumption during operation is substantially less than that of lower rated Introduction Specifically designed for small to medium sized areas the SANYO SAP range is the ideal solution when you need quiet, efficient room air conditioning to create a comfortable environment within

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU 9RLF ASURLF ASU5RLS AOU 9RLFW AOURLFW AOU5RLS R40A CONTENTS. DESCRIPTION OF EACH CONTROL

More information

Development of Air-to-Water Heat Pump for Home Air conditioning/hot Water Supply Combination System with Chilled/Hot Water in European Markets

Development of Air-to-Water Heat Pump for Home Air conditioning/hot Water Supply Combination System with Chilled/Hot Water in European Markets 2 Development of Air-to-Water Heat Pump for Home Air conditioning/hot Water Supply Combination System with Chilled/Hot Water in European Markets - Extending Use of New Heat Pump System in Cold Regions

More information

HEATER, AIR CONDITIONING AND VENTILATION

HEATER, AIR CONDITIONING AND VENTILATION 55-1 GROUP 55 HEATER, AIR CONDITIONING AND VENTILATION CONTENTS GENERAL DESCRIPTION 55-2 HEATER AND AIR CONDITIONING SYSTEM 55-4 HEATER CONTROL 55-6 A/C-ECU 55-7 A/C COMPRESSOR 55-9 CONDENSER 55-9 DUCT

More information

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-EF25/35/42/50VE - E2 and MUZ-EF25/35VEH - E2 have been added. Please void OBH590 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED

More information

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity Liebert HPF The High Performance Floormount Indoor Package Cooling Solution Precision Cooling for Business-Critical Continuity We re Emerson Network Power, backed by Emerson, a global company that brings

More information

Introduction To VRF: System Overview, Applications, & Savings Opportunities

Introduction To VRF: System Overview, Applications, & Savings Opportunities Introduction To VRF: System Overview, Applications, & Savings Opportunities System Overview What is VRF? Zoning System Two-Pipe / Three Pipe System Packaged DDC Control Operates as a Heat Pump Simultaneous

More information

Unico Inverter. Unique and efficient.

Unico Inverter. Unique and efficient. Unico Inverter. Unique and efficient. INTERNATIONAL PATENT PENDING The first fixed air conditioner without outdoor unit featuring DC Inverter technology. Great performance, reduced consumption. Designed

More information

14. Troubleshooting Guide

14. Troubleshooting Guide 14. Guide 14.1 Refrigeration Cycle System In order to diagnose malfunctions, ensure the air conditioner is free from electrical problems before inspecting the refrigeration cycle. Such problems include

More information

ENERGY SAVING STUDY IN A HOTEL HVAC SYSTEM

ENERGY SAVING STUDY IN A HOTEL HVAC SYSTEM ENERGY SAVING STUDY IN A HOTEL HVAC SYSTEM J.S. Hu, Philip C.W. Kwong, and Christopher Y.H. Chao Department of Mechanical Engineering, The Hong Kong University of Science and Technology Clear Water Bay,

More information

PRODUCT CATALOG. You re looking at the future of VRF

PRODUCT CATALOG. You re looking at the future of VRF PRODUCT CATALOG You re looking at the future of VRF From installation to maintenance, LG runs more than 60 global air conditioning academies, each provides training for air conditioning professionals.

More information

Communication Capabilities via a Touch Screen or a Web Browser Further Expand Air-Conditioning Control Possibilities.

Communication Capabilities via a Touch Screen or a Web Browser Further Expand Air-Conditioning Control Possibilities. Communication Capabilities via a Touch Screen or a Web Browser Further Expand Air-Conditioning Control Possibilities. More Freedom to Administrators Connectable up to 128 Indoor Unit Groups (256 indoor

More information

TEST REPORT #31. System Drop-in Test of Refrigerant R-32 in Split Air-conditioning System

TEST REPORT #31. System Drop-in Test of Refrigerant R-32 in Split Air-conditioning System Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Low-GWP Alternative Refrigerants Evaluation Program (Low-GWP AREP) TEST REPORT #31 System Drop-in Test of Refrigerant R-32 in Split Air-conditioning

More information

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free... Solar air collectors for industry and larger halls N S Ø Efficient dehumidification and air heating for free... This booklet contains information about SolarVenti Industrial air solar system. The system

More information

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved Sanyo Section : Section : Section : Section : Section : sip Modbus Guide Configuration Modbus Table Technical Specification Pinouts, Cable Connections & Wiring Alarm Fault Codes Issue : February 009 Section

More information

Heat Pump Product Brochure 2015/2016. Premier Series Hi-Wall Split Systems. Everyday Comfort

Heat Pump Product Brochure 2015/2016. Premier Series Hi-Wall Split Systems. Everyday Comfort Heat Pump Product Brochure 2015/2016 Premier Series Hi-Wall Split Systems Everyday Comfort Everyday Innovation We design with you in mind. You ll find that Haier Heat Pump units are quiet, efficient and

More information

INVERTER IN-CEILING CASSETTE. Ideal for various applications including the lounge, family room, restaurants, hotels, offices and meeting rooms.

INVERTER IN-CEILING CASSETTE. Ideal for various applications including the lounge, family room, restaurants, hotels, offices and meeting rooms. INVERTER IN-CEILING CASSETTE Ideal for various applications including the lounge, family room, restaurants, hotels, offices and meeting rooms. INVERTER TECHNOLOGY PFC Control in Power Input DC Inverter

More information

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,

More information

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1 SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH

More information

Super Modular Multi Design Manual HFC R-410A. Indoor unit. Outdoor unit

Super Modular Multi Design Manual HFC R-410A. Indoor unit. Outdoor unit Ref.-No. SMMS02-AE-10-05 Indoor unit 4-way ceiling cassette MMU-AP0091H, AP0121H, AP0151H, MMU-AP0181H, AP0241H, AP0271H, MMU-AP0301H, AP0361H, AP0481H MMU-AP0561H 2-way ceiling cassette MMU-AP0071WH,

More information

LG AIR CONDITIONING SYSTEMS

LG AIR CONDITIONING SYSTEMS LG AIR CONDITIONING SYSTEMS THE NEW STANDARD IN COMFORT INNOVATIVE COMFORT SOLUTIONS AT LG, WE BELIEVE COMFORT SHOULD ALWAYS BE BEAUTIFUL. 4 Table of Contents INTRODUCTION 04-07 ART COOL 08-11 SINGLE

More information

2015 / 16. price list. Airconditioning systems

2015 / 16. price list. Airconditioning systems 2015 / 16 price list Airconditioning systems TERMS OF BUSINESS General As far as nothing else has been declared, the general terms of business and the agreed purchase conditions including the sales discounts

More information

marine/bespoke split applications

marine/bespoke split applications split applications marine/bespoke evaporators, condensers and split air conditioning systems suitable for a multitude of applications such as coastal, extreme high and low ambients, harsh dusty environments

More information

DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS

DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS AN EXCELLENT CHOICE IN COOLING, COMFORT AND CONVENIENCE Why choose a Mini-Split system? Installing

More information

PANASONIC TROUBLE SHOOTING GUIDE

PANASONIC TROUBLE SHOOTING GUIDE A General Guide To Room Style Products Pipework Pipe sizes and lengths should be as the relevant Technical Guide Both lines should be insulated No line accessories or oil traps should be fitted In cooling

More information

innovative comfort solutions

innovative comfort solutions engineering and specifications Guide duct-free air conditioning systems Art cool inverter flex multi-split floor standing ceiling cassette PTAC PTHP through-the-wall innovative comfort solutions 1 AT LG,

More information

Learn more about Samsung air conditioner at:

Learn more about Samsung air conditioner at: 2014 SAMSUNG New Ducted Air-Conditioner Learn more about Samsung air conditioner at: www.samsung.com/global/business/system-air-conditioner 2014 SAMSUNG NEW DUCTED AIR CONDITIONER CONTENTS Smart Cooling

More information

your comfort. our world. DNSS EcoSave A/C remote monitoring and malfunction prediction

your comfort. our world. DNSS EcoSave A/C remote monitoring and malfunction prediction your comfort. our world. DNSS EcoSave A/C remote monitoring and malfunction prediction What is DNSS EcoSave? The Daikin Network Service System (DNSS EcoSave) is a Daikin developed internet based remote

More information

AIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW -

AIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW - AIR-COOLED CHILLERS APPLIED SYSTEMS www.daikin.eu Cooling Only Heat pump EUWA*5-24KAZW - EUWY*5-24KAZW - Environmental Awareness Daikin and the Environment In recent years, motivated by a global awareness

More information

PRODUCT CATALOG. Indoor Units

PRODUCT CATALOG. Indoor Units PRODUCT CATALOG Indoor Units Life s Good! From installation to maintenance, LG runs more than 60 global air conditioning academies, each provides training for air conditioning professionals. What is LG?

More information

SiBE12-625. D-Series / E-Series. [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump

SiBE12-625. D-Series / E-Series. [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump SiBE12-625 D-Series / E-Series [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump SUPER MULTI NX D-Series / E-Series Cooling Only Indoor Unit FTKS20D3VMW FTKS20CAVMB FDKS25CAVMB

More information

Inverter Air Conditioning for Light Commercial Use

Inverter Air Conditioning for Light Commercial Use Inverter Air Conditioning for Light Commercial Use Index Introducing Light Commercial 4 SDI-Super Digital Inverter 6 DI-Digital Inverter 7 DI Big 8 SDI-Super Digital Inverter & DI-Digital Inverter Lineup

More information

SALES BULLETIN. Key Features. New 7 Series Under Ceiling Indoor Units

SALES BULLETIN. Key Features. New 7 Series Under Ceiling Indoor Units SALES BULLETIN Key Features 1. Chassis completely re designed 2. Increased product range, now includes 6HP model 3. New features to enable easy installation a. Easy access hanger b. Easier wiring connections

More information

How Ground/Water Source Heat Pumps Work

How Ground/Water Source Heat Pumps Work How Ground/Water Source s Work Steve Kavanaugh, Professor Emeritus of Mechanical Engineering, University of Alabama Ground Source s (a.k.a. Geothermal s) are becoming more common as the costs of energy

More information

CoolTeg Plus Chilled Water (CW) version: AC-TCW

CoolTeg Plus Chilled Water (CW) version: AC-TCW version: 12-04-2013 CONTEG DATASHEET TARGETED COOLING CoolTeg Plus Chilled Water (CW) version: AC-TCW CONTEG, spol. s r.o. Czech Republic Headquarters: Na Vítězné pláni 1719/4 140 00 Prague 4 Tel.: +420

More information

Failure code manual. content

Failure code manual. content Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一

More information

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Specifications COOLING ONLY / HEAT PUMP 005 006 007 Capacity (Eurovent) Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Nominal input (Eurovent) Cooling kw 1.89 2.35 2.95 Heating kw 1.97 2.24 2.83 EER

More information

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Air Conditioner Water Heater - A Product of HotSpot Energy LLC Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform

More information

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system. ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2

More information

ASTACEA4 Inspect complex/central air conditioning systems

ASTACEA4 Inspect complex/central air conditioning systems Overview This Unit covers the competences required to inspect complex/central air conditioning systems as defined by the CIBSE TM 44 Figure 1.1: Summary of system types and their component parts. The air

More information

LG AIR CONDITIONERS 2014 Ducted Split System

LG AIR CONDITIONERS 2014 Ducted Split System Australia Pty Ltd. New South Wales / Head Office 2 Wonderland Drive EASTERN CREEK NSW 2766 PH : 02-8805-4000 FAX : 02-8805-4248 AUS-DU1309 Queensland 23 Terrace Place MURARRIE QLD 4172 PH : 07-3908-9000

More information

Why Daikin? 2015 Houston, Texas USA www.daikincomfort.com

Why Daikin? 2015 Houston, Texas USA www.daikincomfort.com Why Daikin? Daikin: The Premium Brand industry leader Daikin is recognized as the world s number one leader in the manufacture of HVAC equipment and refrigerants. For over 90 years, Daikin has grown consistently

More information

Lesson 36 Selection Of Air Conditioning Systems

Lesson 36 Selection Of Air Conditioning Systems Lesson 36 Selection Of Air Conditioning Systems Version 1 ME, IIT Kharagpur 1 The specific objectives of this chapter are to: 1. Introduction to thermal distribution systems and their functions (Section

More information

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER INDOOR UNIT AH-129 AH-MP14 OUTDOOR UNIT AU-129 AU-MP14 CONTENTS SPECIFICATIONS...2 EXTERNAL DIMENSIONS...4 WIRING DIAGRAMS...5 ELECTRICAL PARTS...6 MICROCOMPUTER

More information

Air conditioners Heating & Cooling

Air conditioners Heating & Cooling Air conditioners Heating & Cooling Replacement VRV Cost effective upgrade for R-22 s High efficiency Possibility to increase capacity Limited and planned downtime Limited and phased investment cost www.daikin.eu

More information

utopia Split Systems DC Inverter 7kW-14kW G8 5kW-25kW

utopia Split Systems DC Inverter 7kW-14kW G8 5kW-25kW utopia DC Inverter 7kW-14kW G8 5kW-25kW Split Systems Contents Company profile 4 Product range overview 6 Features and benefits 8 DC Inverter 12 Utopia G8 24 Utopia centrifugal 40 Total heat exchanger

More information

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.

More information

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting

More information

LG Air Conditioning Solutions COMFORT MADE EASY. COMFORT MADE BEAUTIFUL.

LG Air Conditioning Solutions COMFORT MADE EASY. COMFORT MADE BEAUTIFUL. Residential Brochure LG Air Conditioning Solutions COMFORT MADE EASY. COMFORT MADE BEAUTIFUL. LG DUCT-FREE Split SYSTEMS BRING COMFORTING INNOVATION LG Duct-Free Split systems allow you to cool or heat

More information

Versati Air to Water Heat Pump

Versati Air to Water Heat Pump Versati Air to Water Heat Pump VERSATI DC Inverter Multifunctional Air To Water Heat Pump Nowadays, people are increasingly focusing on heating costs as well as environmental issues. Traditional heating

More information