UV-VIS-NIR. Varian Cary 4000, 5000 and 6000i Spectrophotometers
|
|
|
- Elaine Pitts
- 9 years ago
- Views:
Transcription
1 UV-VIS-NIR Varian Cary 4000, 5000 and 6000i Spectrophotometers
2 Varian Cary At the leading edge Varian s Cary range of UV-Vis-NIR spectrophotometers has been synonymous with excellence and high performance for over 50 years. The Cary range has become the standard for researchers wanting to extend the boundaries of spectrophotometric measurement techniques. The range is equally at home in routine laboratories where reliability and easeof-use are vital. In fact, no matter what your measurement challenge, Varian s Cary product range has a solution for you. The new generation Cary series Now, Varian introduces the latest breakthrough in UV-Vis-NIR: the new generation Cary series. Comprising the Cary 4000, 5000 and 6000i instruments, this research grade series sets new standards for UV-Vis-NIR performance. With unsurpassed photometric accuracy and a wide range of flexible accessories, the new Cary series satisfies all your measurement needs and is the only choice for researchers who need to stay at the forefront of their field. Cary 4000 Offering the ultimate in UV-Vis photometric performance from nm, the Cary 4000 sets the industry standard for research and reference spectrophotometers. Cary 5000 With innovative PbSmart technology, the Cary 5000 extends the unparalleled Cary performance into the NIR to 3300 nm. Cary 6000i Having provided the world s first UV-Vis NIR spectrophotometer with InGaAs detection, the Cary 6000i represents the second generation of this technology. No other instrument can match the NIR performance of the Cary 6000i. The wavelength ranges of the Varian Cary 4000, 5000 and 6000i instruments. 2
3
4 What s inside? The new generation Cary series features the Optical Isolation System, which provides all the optical stability of an independently mounted, research grade optical bench. Vibrational noise is reduced, as the optics casting is mounted on an isolated system which floats independently of the spectrophotometer cover and sample compartment. The system has also been insulated from vibrational effects, so you can be sure that your laboratory environment won t affect your instrument s performance. The Cary 4000/5000/6000i instruments also feature the unique LockDown mechanism that ensures you can mount accessories in the sample compartment quickly, easily and reproducibly. With the Cary LockDown mechanism, you ll spend less time on setup and more time on analysis. With Plug-and-Go lamp management, lamps are now easily replaced and pre-aligned, requiring no adjustment. The lamp management electronics ensures that a wider range of lamp designs can be accommodated. Schwarzchild coupling optics ensure the maximum level of light throughput. This produces more accurate measurements at low transmission levels. The slits can be fixed in the NIR as well as the UV-Vis. A large sample compartment, with a removable floor plate, gives you maximum flexibility when mounting samples. 4 The unique precision LockDown mechanism allows you to position your accessories quickly and reproducibly in the sample compartment.
5 Cary s out-of-plane double Littrow monochromator design minimizes photometric noise and stray light, providing excellent resolution. The Optical Isolation System incorporates a floating solid aluminium casting that isolates the optics from external disturbances. The monochromator and sample compartments have separate nitrogen purging capabilities, allowing the sample compartment to be purged at a higher rate than the instrument. The extended dynamic range of the Cary instruments is a result of its advanced electronics design. With reference beam attenuation, the instruments can typically measure absorbances beyond 8. A choice of PbS or InGaAs detectors provides flexibility in the NIR. The optics are silica overcoated, so that they can be cleaned without damage to the reflective surface. 5
6 Unparalleled performance The new generation Cary range begins with the Cary This instrument sets the standard for photometric noise, range and linearity, providing excellent resolution across the UV-Visible spectrum from nm. Featuring Varian s new Optical Isolation System, the Cary 4000 provides advances in noise and stray light reduction, making it ideal for the most challenging research applications or as your own primary reference UV-Vis spectrophotometer. The Cary 5000 combines unparalleled Cary performance with Varian s innovative PbSmart technology, extending the wavelength range into the NIR to 3300 nm. PbSmart optimizes the performance of the PbS NIR detector in real time, providing noise and linearity performance never before achieved using this detector technology. The Cary 5000 can be used to achieve significant performance breakthroughs across a range of applications from quantifying out-of-band blocking characteristics of band pass filters or measuring the high transmission of next generation fibre optic materials to QC applications for testing of raw materials or finished pharmaceutical products. 6
7 Demonstrating signal-to-noise (S:N) scanning mode, this scan shows the excellent precision obtained at both high and low transmission values for this reference filter. Shown here is the same sample measured with (bottom) and without (top) S:N scanning mode. Signal-to-noise (S:N) mode is a unique scanning mode available only on the Cary instruments. It allows you to control the level of precision you want across the whole scan. This saves time because the system will scan quickly in areas of high energy throughput and slow down in areas where the energy throughput is less. In addition, S:N mode provides the same precision throughout the lifetime of the instrument, no matter what its age. This makes S:N scanning ideal for standards and reference laboratories and laboratories conforming to strict regulatory protocols. Even at a background absorbance of over 4.5, small changes in highly turbid samples such as Cytochrome P450 can be measured. 7 Cary Praying Mantis Diffuse Reflectance Accessory Cary Automated Double Aperture Accessory Cary Variable Angle Specular Reflectance Accessory Cary Rear Beam Attenuators Cary Specular Reflectance Accessory
8 The widest photometric range When you need to push the limits of photometric measurement, only Varian s new generation Cary spectrophotometers can break the performance barriers. The Cary series has the widest photometric range available, across the broadest wavelength range. The instruments can measure absorbances exceeding 6 from the UV-Vis to the NIR. This means you can avoid time consuming sample and standard dilutions, and you can confidently measure the most challenging of samples. Whether you want to collect kinetics data in situ without dilution, or measure turbid, highly scattering biological samples without using integrating spheres, you can with a Cary instrument. And Cary s wide photometric range makes light work of the highest optical density filters and the lowest reflectance AR lenses. Linearity The quality of your results is only as good as the linearity performance of your spectrophotometer. Whether you re making solution measurements at the limit of detection, measuring highly absorbing chemical process streams or discerning the smallest difference in optical thickness, the superb photometric linearity of the Cary range guarantees the validity of your results. 8 The Diffuse Reflectance Accessory is ideal for measuring a wide range of solid and liquid samples.
9 The addition of two blue filters shows the superior photometric range and linearity of the Cary instruments in the UV-Vis. The insert compares the spectral addition of the filters to their combined measurement, a difference of less than 8 x 10-8 %T. The quantitative analysis of aqueous potassium permanganate further demonstrates the excellent photometric accuracy and range of the Cary instruments. Measurement at 555 nm permits analysis from ppm without dilution. The plot of Absorbance vs Concentration (shown below) highlights the wide dynamic range and inherent linearity (r 2 = 0.999) of the Cary spectrophotometers. 9
10 Specialized spectrophotometers for specialized applications Advanced NIR performance for advanced photonics With an operating range from nm, the Cary 6000i is the instrument of choice for users needing to keep abreast of rapidly developing photonics and communications technologies both now and in the future. Varian pioneered the world s first double beam UV-Vis-NIR spectrophotometer with InGaAs detection to take advantage of the dramatically reduced noise and improved sensitivity the detector provides in the NIR. The Cary 6000i represents the second generation of this technology and is the world s most advanced UV-Vis-NIR spectrophotometer with InGaAs detection. The InGaAs detector provides superior signal-to-noise performance compared to conventional lead sulfide detectors. This results in improved detection limits and increased scan rates, giving you cleaner spectra with better resolution in less time. The unmatched NIR capabilities of the Cary 6000i are further enhanced by the Cary Optical Isolation system and Peltier detector cooling. Like the Cary 4000 in the UV-Vis region, the 6000i can be used as a primary reference spectrophotometer in the NIR, providing absolute accuracy measurements without the need for reference to expensive external calibration standards. The addition of three filters shows the superior photometric range and linearity of the Varian Cary instruments in the NIR. The actual and predicted measurements show excellent correlation across the entire NIR wavelength range measured. Using the Cary 6000i, a high resolution NIR scan of water vapor clearly resolves absorption bands around 940 nm which are barely visible on standard spectrophotometers. The fine resolution delivered by the Cary 6000i is made possible through the use of a dedicated 600 lines/mm NIR diffraction grating in combination with InGaAs NIR detection. 10
11 Varian s technology advances don t stop at the spectrophotometer. The superior InGaAs and PbSmart NIR detection systems also power Varian s comprehensive range of integrating sphere accessories. Available in two diameters (150 mm or 110 mm) and three model types, you can swap from PbS to InGaAs to solve the most challenging diffuse reflectance measurements. Varian, Inc. DRAs offer a unique range of features, so there s always a model to suit your needs. (Model number indicates the wavelength limit in nanometers.): Internal/External DRA-900 Offering exceptionally low photometric noise, a wide photometric range and good linearity. Internal/External DRA-1800 The world s only PMT/InGaAs DRA, providing superior signal to noise performance for improved detection limits and increased scan rates. Get cleaner spectra with better resolution more quickly. Internal/External DRA-2500 Extending the Cary 5000 s PbSmart NIR detector management, the DRA PbS NIR detector is peltier cooled and optimized in real time, offering exceptional performance. The External DRA (150 mm integrating sphere) is ideal for reflectance or transmission measurements of large and physically challenging samples. Multiple sample mounting options are available. 11
12 Simply smarter software New Cary WinUV software ensures that Varian s widely acclaimed UV-Vis-NIR software is now even more powerful and easier to use. The modular design of the Cary WinUV software means that it can be tailored to suit your analytical requirements whether it s a materials science application using basic concentration measurements or life science applications requiring advanced enzyme kinetics or thermal control. But it doesn t stop there. Cary WinUV is completely customizable using the powerful built-in Applications Development Language (ADL). ADL gives you the capability to modify the WinUV software to meet your most specific applications ensuring that no matter what analytical challenges the future holds, you will have the capability to meet them. With standard software packages designed to meet most application needs and the power and flexibility of ADL, the Cary WinUV software is sure to meet all your requirements. 21 CFR Part 11 compatibility Optional 21 CFR Part 11 and GLP (Good Laboratory Practice) compatibility is ideal for users in the pharmaceutical industry or anyone requiring regulatory compliance. In addition, the unique Validate application enables immediate certification of your instrument against factory, BP/EP, USP (British/European, U.S. Pharmacopoeia) specifications. 12
13 Choose your operating system Cary WinUV software is compatible with both Microsoft Windows XP and Windows Enhanced graphics features The graphics control module has automatic peak labeling, zoom, free and tracking cursor, multiple ordinate and abscissa formats, smart copy/paste and overlay modes, making spectral interpretation and presentation for publications a breeze. Enhanced file transfer and report export capabilities give Cary WinUV greater connectivity than any other UV-Vis-NIR software. The Auto Convert function allows you to convert your data files automatically for use in another program. You can also elect to store your data files in formats that can be directly imported into a spreadsheet. The optional Color Calculation software is compatible with the international color commission (CIE) and ASTM standards, and is ideal for users in the pharmaceutical, textile, automotive, paint or graphic arts industries. Advanced spectrum calculator Use the spectrum calculator to apply mathematical operations, including addition, subtraction, division, multiplication, log and square root functions, to spectra. The calculator also features mean, normalization, smoothing, up to fourth order derivatives, integration and the Kubelka-Munk correction algorithm. Cary WinUV s extensive online help includes step-by-step videos of hardware setup and routine maintenance procedures ensuring you can get up and running quickly. 13
14 Precision engineered for greater flexibility and versatility The Cary series has been designed for flexibility and versatility. Whether your application is optics, powders, fabrics, gases, liquids, films or coatings, there is a Cary accessory to meet your needs. Our fibre optic technologies take measurements beyond the sample compartment, ensuring you can perform a full range of measurements from advanced specular and diffuse reflectance measurements to simple solution transmittance and absorbance. If you have the application, we have the solution. You can count on Varian s Cary spectrophotometers to meet all your needs today and tomorrow. Lock it down and walk away Throw down your tools! The new generation Cary series features the unique precision LockDown mechanism that allows you to position your accessories in your spectrophotometer quickly and reproducibly. With just a flick of the wrist, the Cary LockDown system permits quick mounting, release and changeover of accessories so you can spend more time on analysis and less time setting up. The Cary LockDown system means you can confidently mount any accessory in the instrument, in exactly the same place time-after-time eliminating tools and time-consuming alignment procedures. Plug-and-Go The Cary s Plug-and-Go lamp management feature makes lamp replacement easy, as lamps are pre-aligned and don t require any adjustments. And, it s more flexible with the ability to accommodate a wider range of lamp designs to match your application needs. A mercury lamp module for wavelength accuracy validation is supplied with all high-end Cary spectrophotometers, allowing you to verify wavelength accuracy in one simple step. Safety Although Varian s products are designed to be safe and to comply with all applicable regulatory requirements, it is important to be familiar with the hazards associated with these products. For full details, refer to The Cary Series is certified to comply with the requirements of the EMC and LV directives of the European Union Insert accessory into the sample compartment 2 Position accessory over mounting holes 3 Flick the switch to lock the accessory down
15 A family of solutions Varian s vast array of hardware solutions ensures you can handle the widest variety of sample sizes from the smallest etalon to uncut sheet glass, from micro-flowcells to long path gas cells. The huge Cary sample compartment accommodates most sample sizes, while the removable sample compartment floor means even more flexibility is provided. The new generation Cary series are part of Varian s range of Cary molecular spectrophotometers, which also includes the Cary 50, 100 and 300 UV-Vis spectrophotometers and the Cary Eclipse fluorescence spectrometer. With xenon flash lamp technology, plug-and-identify electronics and featurepacked, intuitive software, the Cary Eclipse instrument embodies the Cary name. When combined with the optional solid sample holder, the Cary Eclipse can be used for a variety of materials science applications from measuring optical components for unwanted fluorescence to measuring specialty chemicals such as optical brighteners. For the measurement of large samples such as optical filters, the Cary Eclipse can be used in conjunction with Varian s fibre optic system (as shown above). The Cary Eclipse fibre optic system takes the light to the sample, enabling the fluorescence spectra of large, heavy and oddly shaped objects such as rocks, gems and other minerals to be measured. For further information on Varian s range of Cary 50, 100, 300 UV-Vis or Cary Eclipse fluorescence spectrophotometers, ask your Varian sales representative for a brochure, or visit our website at To keep your Cary instruments running smoothly, Varian also offers a wide range of the highest quality consumable supplies, including cuvettes, reference materials and lamps. 15
16 Varian, Inc. serving worldwide markets in: Agriculture Basic Chemical Biotechnology Clinical Electronics Environmental Photonics Toxicology Pharmaceutical Food and Beverage Metals and Mining Petroleum and Petrochemical Varian, Inc. is committed to a process of continuous improvement which demands that we understand and then meet or exceed the needs and expectations of our customers both inside and outside the company in everything we do. Varian Sales and Dealer Offices QUALITY SYSTEM C E R T I F I E D All trademarks are the property of their respective owners. Specifications subject to change without notice. Varian, Inc. North America , Europe The Netherlands Asia Pacific Australia Latin America Brazil China Japan Korea Taiwan India Other sales offices and dealers throughout the world GC LC MS AAS ICP UV-Vis-NIR FT-IR Raman Fluorescence Dissolution NMR Consumable Products /04 Printed in Australia Printed on environmentally friendly paper. Design: Digital Image. Photography: Parallax
Agilent Cary 4000/5000/6000i Series UV-Vis-NIR
Agilent Cary 4000/5000/6000i Series UV-Vis-NIR Guaranteed specifications Design overview Double beam, ratio recording, double out-of-plane Littrow monochromator UV-Vis-NIR spectrophotometer (Agilent Cary
UV-Vis spectrophotometers
UV-Vis spectrophotometers an Advanced Digital Technology EXPERIENCE SECOMAM is proud to provide the new fourthgeneration UVIKON ultraviolet-visible spectrophotometers.with more than five decades of experience
UV-VIS VARIAN, INC. Cary 100/300 UV-Vis. S p e c t r o p h o t o m e t e r s
UV-VIS VARIAN, INC. Cary 100/300 UV-Vis S p e c t r o p h o t o m e t e r s Unmatched quality and performance Outstanding performance, flexibility, and ease of use are what you can expect from Varian s
UV-VIS-NIR Cary 4000, 5000, 6000i Spectrophotometers Preliminary Performance Data
UV-VIS-NIR Spectrophotometers Preliminary Performance Data UV-VIS-NIR Spectrophotometers Preliminary Performance Data Cary UV-Vis-NIR spectrophotometers are manufactured according to a Quality system certified
Agilent Cary 60 UV-Vis
Agilent Cary 60 UV-Vis Efficient. Accurate. Flexible. Specifications Introduction The Agilent Cary 60 UV-Vis spectrophotometer is efficient, accurate and flexible, and is designed to meet both current
Fundamentals of modern UV-visible spectroscopy. Presentation Materials
Fundamentals of modern UV-visible spectroscopy Presentation Materials The Electromagnetic Spectrum E = hν ν = c / λ 1 Electronic Transitions in Formaldehyde 2 Electronic Transitions and Spectra of Atoms
Fiber Optic Sampling by UV/Vis and UV/Vis/NIR Spectroscopy
Fiber Optic Sampling by UV/Vis and UV/Vis/NIR Spectroscopy UV/VIS AND UV/VIS/NIR SPECTROSCOPY A P P L I C A T I O N N O T E Introduction The availability and applications of fiber optic sampling in UV/Vis
User guide for Cary 5000 absorption spectrometer with external DRA 1800 attachment.
User guide for Cary 5000 absorption spectrometer with external DRA 1800 attachment. (last updated 03/17/2016) This guide is for use of the Cary 5000 with the DRA only. For use without the DRA as a standard
Reflectance Measurements of Materials Used in the Solar Industry. Selecting the Appropriate Accessories for UV/Vis/NIR Measurements.
T e c h n i c a l N o t e Reflectance Measurements of Materials Used in the Solar Industry UV/Vis/NIR Author: Dr. Jeffrey L. Taylor PerkinElmer, Inc. 710 Bridgeport Avenue Shelton, CT 06484 USA Selecting
Cary 100 Bio UV-Vis Operating Instructions 09/25/2012 S.V.
1234 Hach Hall 515-294-5805 www.cif.iastate.edu Cary 100 Bio UV-Vis Operating Instructions 09/25/2012 S.V. Location: Contact: 1240 Hach Hall Steve Veysey, 1234 Hach Hall Safety All researchers working
instruments Analytical Instruments for Science
instruments Analytical Instruments for Science instruments Contents PAGE NO. Introduction 4 T60 UV-Vis Spectrophotometer 6 T70 UV-Vis Spectrophotometer 10 T80 UV-Vis Spectrophotometer 14 T90+ UV-Vis Spectrophotometer
Introduction to Fourier Transform Infrared Spectrometry
Introduction to Fourier Transform Infrared Spectrometry What is FT-IR? I N T R O D U C T I O N FT-IR stands for Fourier Transform InfraRed, the preferred method of infrared spectroscopy. In infrared spectroscopy,
MB3600 Versatile FT-NIR analyzer designed for your industry The most reliable FT-NIR specifically designed for QA/QC
Measurement & Analytics Measurement made easy MB3600 Versatile FT-NIR analyzer designed for your industry The most reliable FT-NIR specifically designed for QA/QC MB3600 FT-NIR spectrometer for your industry
UV/VIS/IR SPECTROSCOPY ANALYSIS OF NANOPARTICLES
UV/VIS/IR SPECTROSCOPY ANALYSIS OF NANOPARTICLES SEPTEMBER 2012, V 1.1 4878 RONSON CT STE K SAN DIEGO, CA 92111 858-565 - 4227 NANOCOMPOSIX.COM Note to the Reader: We at nanocomposix have published this
Measurement of Enhanced Specular Reflector (ESR) Films Using a LAMBDA 1050 UV/Vis/NIR Spectrometer and URA Accessory
FIELD APPLICATION REPORT UV/Vis/NIR Spectroscopy Author: Frank Padera Shelton, CT Contributor: Chris Lynch Shelton, CT Measurement of Enhanced Specular Reflector (ESR) Films Using a LAMBDA 1050 UV/Vis/NIR
QUANTITATIVE INFRARED SPECTROSCOPY. Willard et. al. Instrumental Methods of Analysis, 7th edition, Wadsworth Publishing Co., Belmont, CA 1988, Ch 11.
QUANTITATIVE INFRARED SPECTROSCOPY Objective: The objectives of this experiment are: (1) to learn proper sample handling procedures for acquiring infrared spectra. (2) to determine the percentage composition
Hitachi U-4100 UV-vis-NIR spectrophotometer (341-F)
Hitachi U-4100 UV-vis-NIR spectrophotometer (341-F) Please contact Dr. Amanda Young for training requests and assistance: 979-862-6845, [email protected] Hardware Our spectrophotometer is made up of
Hellma. Where precision becomes an art. Calibration standards for spectrophotometers. 2008 by Hellma www.hellma-worldwide.com
Hellma. Where precision becomes an art. Calibration standards for spectrophotometers 2008 by Hellma www.hellma-worldwide.com Contents Calibration of spectrophotometers 3 Traceability of the calibration
Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs
Spectroscopy Biogeochemical Methods OCN 633 Rebecca Briggs Definitions of Spectrometry Defined by the method used to prepare the sample 1. Optical spectrometry Elements are converted to gaseous atoms or
VWR SPECTROPHOTOMETERS
VWR SPECTROPHOTOMETERS Reliable Accurate Easy to Use New_Spectrophotometry_v2.indd 2 Your first choice for spectrophotometry 5/9/2014 2:22:18 PM Quality Guaranteed VWR SPECTROPHOTOMETERS Single Beam Units
MCAL Spectrophotometry. Spectrophotometry
MCAL Spectrophotometry Instruments include: Cary 50 UV-vis Spectrophotometer Eclipse Spectrofluorometer HPLC Diode Array and Fluorescence ICP-OES with CCD detection Spectrophotometry The instruments all
EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions.
EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions. Outcomes After completing this experiment, the student should be able to: 1. Prepare
Spectral Measurement Solutions for Industry and Research
Spectral Measurement Solutions for Industry and Research Hamamatsu Photonics offers a comprehensive range of products for spectroscopic applications, covering the, Visible and Infrared regions for Industrial,
Shimadzu UV-VIS User s Guide
Shimadzu UV-VIS User s Guide 1) Push the F4 button on the UV-VIS instrument keypad. This will enable PC control. Push the F4 Button 2) Log into the UV-VIS software with your username and password. 3) After
Using the Spectrophotometer
Using the Spectrophotometer Introduction In this exercise, you will learn the basic principals of spectrophotometry and and serial dilution and their practical application. You will need these skills to
Laboratory #3 Guide: Optical and Electrical Properties of Transparent Conductors -- September 23, 2014
Laboratory #3 Guide: Optical and Electrical Properties of Transparent Conductors -- September 23, 2014 Introduction Following our previous lab exercises, you now have the skills and understanding to control
Uses of Derivative Spectroscopy
Uses of Derivative Spectroscopy Application Note UV-Visible Spectroscopy Anthony J. Owen Derivative spectroscopy uses first or higher derivatives of absorbance with respect to wavelength for qualitative
Measurement & Analytics Measurement made easy
Measurement & Analytics Measurement made easy MB3600-PH Versatile FT-NIR analyzer for the life sciences and pharmaceutical industries Designed for QA/QC, research and development and at-line PAT applications
73 Series Spectrophotometers
73 Series Spectrophotometers The 73 series introduces four new spectrophotometers to the extensive Jenway range. These spectrophotometers use icon driven software and have an improved navigation system
Experiment #5: Qualitative Absorption Spectroscopy
Experiment #5: Qualitative Absorption Spectroscopy One of the most important areas in the field of analytical chemistry is that of spectroscopy. In general terms, spectroscopy deals with the interactions
Qualitative NIR Analysis for Ingredients in the Baking Industry
Overview The challenge to all baking companies in today s economy is to operate plants as efficiently as possible, with a focus on quality and keeping costs in check. With regulatory issues becoming more
Austin Peay State University Department of Chemistry Chem 1111. The Use of the Spectrophotometer and Beer's Law
Purpose To become familiar with using a spectrophotometer and gain an understanding of Beer s law and it s relationship to solution concentration. Introduction Scientists use many methods to determine
Problem Set 6 UV-Vis Absorption Spectroscopy. 13-1. Express the following absorbances in terms of percent transmittance:
Problem Set 6 UV-Vis Absorption Spectroscopy 13-1. Express the following absorbances in terms of percent transmittance: a 0.051 b 0.918 c 0.379 d 0.261 e 0.485 f 0.072 A = log P o /P = log1/t = - log T
University of Wisconsin Chemistry 524 Spectroscopic Applications (GFAA, ICP, UV/Vis, Fluorescence)
University of Wisconsin Chemistry 524 Spectroscopic Applications (GFAA, ICP, UV/Vis, Fluorescence) For this laboratory exercise, you will explore a variety of spectroscopic methods used in an analytical
Measuring of optical output and attenuation
Measuring of optical output and attenuation THEORY Measuring of optical output is the fundamental part of measuring in optoelectronics. The importance of an optical power meter can be compared to an ammeter
Raman Spectroscopy Basics
Raman Spectroscopy Basics Introduction Raman spectroscopy is a spectroscopic technique based on inelastic scattering of monochromatic light, usually from a laser source. Inelastic scattering means that
Ultraviolet-Visible (UV-Vis) Spectroscopy Background Information
1 Ultraviolet-Visible (UV-Vis) Spectroscopy Background Information Instructions for the Operation of the Cary 300 Bio UV-Visible Spectrophotometer See the Thermo OMNIC Help reference on page 49. Ultraviolet-Visible
Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry
Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry Jon H. Hardesty, PhD and Bassam Attili, PhD Collin College Department of Chemistry Introduction: In the last lab
Improved predictive modeling of white LEDs with accurate luminescence simulation and practical inputs
Improved predictive modeling of white LEDs with accurate luminescence simulation and practical inputs TracePro Opto-Mechanical Design Software s Fluorescence Property Utility TracePro s Fluorescence Property
Appendix 5 Overview of requirements in English
Appendix 5 Overview of requirements in English This document is a translation of Appendix 4 (Bilag 4) section 2. This translation is meant as a service for the bidder and in case of any differences between
Optical or Acoustic Process measurement of liquids Turbidity Colour Oil in Water Water in Oil Oil on Water Process UV- Photometry
Optical or Acoustic Process measurement of liquids Turbidity Colour Oil in Water Water in Oil Oil on Water Process UV- Photometry Models UVS-1, MoniSpec-UV & MoniSpec-UVd Model UVS-1 general information
Reprint (R22) Avoiding Errors in UV Radiation Measurements. By Thomas C. Larason July 2001. Reprinted from Photonics Spectra, Laurin Publishing
Reprint (R22) Avoiding Errors in UV Radiation Measurements By Thomas C. Larason July 2001 Reprinted from Photonics Spectra, Laurin Publishing Gooch & Housego 4632 36 th Street, Orlando, FL 32811 Tel: 1
SGS: Das Scanning Grating Spektrometer Ein kleines, günstiges Spektrometermodul auf Basis eines dispersiven Mikrosystems
the leading supplier of Micro Scanning Devices Your Micro Optical Solution IPHT-Workshop 11.-12.03.08 We move the light for you! SGS: Das Scanning Grating Spektrometer Ein kleines, günstiges Spektrometermodul
The Sievers 900 Series TOC Analyzers
GE Water & Process Technologies Analytical Instruments The Sievers 900 Series TOC Analyzers imagination at work Delivering Next-Generation Ease of Use, Productivity, and Reliability The Sievers* 900 Series
TotalChrom. Chromatography Data Systems. Streamlining your laboratory workflow
TotalChrom Chromatography Data Systems Streamlining your laboratory workflow maximize productivity with TotalChrom CDS Acquiring, processing, reporting, reviewing and approving data is a streamlined series
Hitachi Spectrophotometer
Hitachi Spectrophotometer Spectrophotometer Meeting a Wide Range of Analytical Needs from Liquid to Solid Sample Measurements Single monochromator U-3900 Stray light : 0.015% or less Photometric range
Back to Basics Fundamentals of Polymer Analysis
Back to Basics Fundamentals of Polymer Analysis Using Infrared & Raman Spectroscopy Molecular Spectroscopy in the Polymer Manufacturing Process Process NIR NIR Production Receiving Shipping QC R&D Routine
Flame Direct Attach UV-VIS Integrated Sampling System Installation and Operation Instructions
Flame Direct Attach UV-VIS Integrated Sampling System Installation and Operation Instructions Description The Flame Integrated Sampling System (FLAME-DA-CUV-UV-VIS) is a snap-on, direct-attach 1 cm cuvette
Chemistry 111 Lab: Intro to Spectrophotometry Page E-1
Chemistry 111 Lab: Intro to Spectrophotometry Page E-1 SPECTROPHOTOMETRY Absorption Measurements & their Application to Quantitative Analysis study of the interaction of light (or other electromagnetic
HP 70950B OPTICAL SPECTRUM ANALYZER
HP 71450B, 71451B, and 71452B Optical Spectrum Analyzers Technical Specifications Spectral Measurements from 600 to 1700 nm HP 70950B OPTICAL SPECTRUM ANALYZER OPTICAL INPUT The HP 71450B, 71451B, and
Graphite Furnace AA, Page 1 DETERMINATION OF METALS IN FOOD SAMPLES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY (VERSION 1.
Graphite Furnace AA, Page 1 DETERMINATION OF METALS IN FOOD SAMPLES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY I. BACKGROUND (VERSION 1.0) Atomic absorption spectroscopy (AAS) is a widely used
FTIR Instrumentation
FTIR Instrumentation Adopted from the FTIR lab instruction by H.-N. Hsieh, New Jersey Institute of Technology: http://www-ec.njit.edu/~hsieh/ene669/ftir.html 1. IR Instrumentation Two types of instrumentation
Application of Automated Data Collection to Surface-Enhanced Raman Scattering (SERS)
Application Note: 52020 Application of Automated Data Collection to Surface-Enhanced Raman Scattering (SERS) Timothy O. Deschaines, Ph.D., Thermo Fisher Scientific, Madison, WI, USA Key Words Array Automation
MB3000-PH FT-IR spectrometer for the pharmaceutical industry Designed for QA/QC, formulation, research and development laboratory applications
Measurement & Analytics Measurement made easy MB3000-PH FT-IR spectrometer for the pharmaceutical industry Designed for QA/QC, formulation, research and development laboratory applications MB3000-PH FT-IR
Single Mode Fiber Lasers
Single Mode Fiber Lasers for Industrial and Scientific Applications T h e P o w e r t o T r a n s f o r m T M IPG s Single Mode Fiber Lasers Advantages IPG's YLR-SM Series represents a break-through generation
The Measurement of Sensitivity in Fluorescence Spectroscopy
The Measurement of Sensitivity in Fluorescence Spectroscopy Among instrumental techniques, fluorescence spectroscopy is recognized as one of the more sensitive. In fluorescence, the intensity of the emission
EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline
EXPERIMENT 5 Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline UNKNOWN Submit a clean, labeled 100-mL volumetric flask to the instructor so that your unknown iron solution
Determination of the Mass Percentage of Copper in a Penny. Introduction
Determination of the Mass Percentage of Copper in a Penny Introduction This experiment will cost you one penny ($0.01). The penny must be minted after 1983. Any penny will do; for best results the penny
Optical Lab Room 1122 Nexus 670 and Magna 560 Instructions Feb. 26, 2013
Optical Lab Room 1122 Nexus 670 and Magna 560 Instructions Feb. 26, 2013 To get set up to use the FTIR systems, first contact Scott at extension 51806 e- mail [email protected] to make appointment for training/orientation
Spetec. Laminar Flow Box. Portable Clean Room Technology
Spetec Laminar Flow Box Portable Clean Room Technology 1 Fundamentals Portable Clean Room Technology Laminar Flow The basis for the development of the clean room technology was first established in the
PRODUCT INFORMATION. Insight+ Uses and Features
PRODUCT INFORMATION Insight+ Traditionally, CAE NVH data and results have been presented as plots, graphs and numbers. But, noise and vibration must be experienced to fully comprehend its effects on vehicle
UV-VISIBLE SPECTROPHOTOMETER
instruments UV-VISIBLE SPECTROPHOTOMETER PRODUCT BROCHURE Analytical Instruments for Science Contents PAGE NO. Introduction 4 T60 UV-Vis Spectrophotometer 6 T70 UV-Vis Spectrophotometer 10 T80 UV-Vis Spectrophotometer
P R E A M B L E. Facilitated workshop problems for class discussion (1.5 hours)
INSURANCE SCAM OPTICS - LABORATORY INVESTIGATION P R E A M B L E The original form of the problem is an Experimental Group Research Project, undertaken by students organised into small groups working as
Copyright 1999 2010 by Mark Brandt, Ph.D. 12
Introduction to Absorbance Spectroscopy A single beam spectrophotometer is comprised of a light source, a monochromator, a sample holder, and a detector. An ideal instrument has a light source that emits
haze-gard i The objective standard for a clear view Global communication Reliable and Precise
haze-gard i The objective standard for a clear view Transparent products can have a milky or fuzzy appearance dependent on its light scattering behaviour. The haze-gard i quantifies the visual perception
WATERS QUANTITATIVE ANALYSIS solutions
More sensitivity. More speed. What more can you ask for in a complete quantitative analysis solution? WATERS QUANTITATIVE ANALYSIS solutions THE CHALLENGE OF QUANTITATIVE ANALYSIS Tandem mass spectrometry,
Specifying Plasma Deposited Hard Coated Optical Thin Film Filters. Alluxa Engineering Staff
Specifying Plasma Deposited Hard Coated Optical Thin Film Filters. Alluxa Engineering Staff December 2012 Specifying Advanced Plasma Deposited Hard Coated Optical Bandpass and Dichroic Filters. Introduction
Image Area EXCEPTIONAL PERFORMANCE FOR CHALLENGING MERCURY ANALYSES. FIMS 100 and 400. Flow Injection Mercury Systems
Image Area EXCEPTIONAL PERFORMANCE FOR CHALLENGING MERCURY ANALYSES FIMS 100 and 400 Flow Injection Mercury Systems Delivering the Performance You Need The determination and monitoring of sub-ppb concentrations
We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement
MAS 40 Mini-Array Spectrometer light measurement Features at a glance Cost-effective and robust CCD spectrometer technology Standard USB interface Compatible with all Instrument Systems measuring adapters
Components for Infrared Spectroscopy. Dispersive IR Spectroscopy
Components for Infrared Spectroscopy Mid-IR light: 00-000 cm - (5.5 m wavelength) Sources: Blackbody emitters Globar metal oxides Nernst Glower: Silicon Carbide Detectors: Not enough energy for photoelectric
Application Note #503 Comparing 3D Optical Microscopy Techniques for Metrology Applications
Screw thread image generated by WLI Steep PSS angles WLI color imaging Application Note #503 Comparing 3D Optical Microscopy Techniques for Metrology Applications 3D optical microscopy is a mainstay metrology
C101-E142 TALK LETTER. Vol. 16
C101-E142 TALK LETTER Vol. 16 Retrospective of Shimadzu UV-VIS Spectrophotometers from Initial Release to Today ------- 02 Application: Expertise for Measuring Transmittance in Solid Samples and Corresponding
Nano-Spectroscopy. Solutions AFM-Raman, TERS, NSOM Chemical imaging at the nanoscale
Nano-Spectroscopy Solutions AFM-Raman, TERS, NSOM Chemical imaging at the nanoscale Since its introduction in the early 80 s, Scanning Probe Microscopy (SPM) has quickly made nanoscale imaging an affordable
Pore size and BET surface area. analysis at your fingertips. SA 3100. Gas Adsorption Analyzer
Pore size and BET surface area analysis at your fingertips. SA 3100 Gas Adsorption Analyzer The History of Beckman Coulter Particle Characterization Introducing The SA 3100 Surface Area and Pore Size Analyzer
Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data
Low cost ICP-OES analysis high quality data The NEW Thermo Scientific icap 7000 Series ICP-OES provides low cost multi-element analysis for measuring trace elements in a diverse sample range. The instrument
DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS
DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display
X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software
X-Series Signal Analysis Future-ready instruments Consistent measurement framework Broadest set of applications and software Arrive Ahead with X-Series We can t predict the future, but Agilent can help
Raman spectroscopy Lecture
Raman spectroscopy Lecture Licentiate course in measurement science and technology Spring 2008 10.04.2008 Antti Kivioja Contents - Introduction - What is Raman spectroscopy? - The theory of Raman spectroscopy
Signal to Noise Instrumental Excel Assignment
Signal to Noise Instrumental Excel Assignment Instrumental methods, as all techniques involved in physical measurements, are limited by both the precision and accuracy. The precision and accuracy of a
MB3600-HP12 / Measurement & Analytics. Laboratory FT-NIR Heavy Oils Analyzer Crude oil, fuel oil, heavy oil upgrader unit feeds
MB3600-HP12 / Measurement & Analytics Laboratory FT-NIR Heavy Oils Analyzer Crude oil, fuel oil, heavy oil upgrader unit feeds Adapted for crude oil, fuel oil and heavy oil upgrader unit feed applications
Passive Remote Sensing of Clouds from Airborne Platforms
Passive Remote Sensing of Clouds from Airborne Platforms Why airborne measurements? My instrument: the Solar Spectral Flux Radiometer (SSFR) Some spectrometry/radiometry basics How can we infer cloud properties
We bring quality to light. ISP Series Integrating Spheres
We bring quality to light. ISP Series Integrating Spheres Theory ISP-Series ISP 75 / ISP 100 / ISP 150L ISP 250 ISP 500 ISP 1000 ISP 2000 The Integrating Sphere The working principle Using integrating
product overview pco.edge family the most versatile scmos camera portfolio on the market pioneer in scmos image sensor technology
product overview family the most versatile scmos camera portfolio on the market pioneer in scmos image sensor technology scmos knowledge base scmos General Information PCO scmos cameras are a breakthrough
Simplicity. Reliability. Performance
Simplicity Reliability Performance ICP Without Compromise At Teledyne Leeman Labs atomic spectroscopy is our business, our only business. We are deeply committed to providing you with technically superior
Product Range Overview
Product Range Overview Stereo Optical Inspection Microscopes Non-Contact Measurement Systems Laboratory Microscopes Metallurgical Microscopes FM 557119 Vision Engineering Ltd has been certificated for
Agilent 4339B/4349B High Resistance Meters
Agilent 4339B/4349B High Resistance Meters Technical Overview Within Budget Without Compromise Introducing the Agilent Technologies 4339B and 4349B High Resistance Meters Used for Making Ultra- High Resistance
HIGH-RESOLUTION LED MODULES PERFECT VISUAL SOLUTIONS
HIGH-RESOLUTION LED MODULES PERFECT VISUAL SOLUTIONS OUR eyeled SERIES DEVELOPED FOR DEMANDING APPLICATIONS: CONTROL STANDARD epanel LED modules for standard installations of seamless video walls with
Application Note: Absorbance
Units Units Theory of absorbance Light absorption occurs when atoms or molecules take up the energy of a photon of light, thereby reducing the transmission of light as it is passed through a sample. Light
MPA. Innovation with Integrity. Multi Purpose Analyzer FT-NIR
MPA Multi Purpose Analyzer Innovation with Integrity FT-NIR Discover the Flexibility of FT-NIR Spectroscopy The MPA is the result of almost 40 years of experience in the engineering and production of FT-IR
Thermo Scientific GENESYS 10S Series UV-Visible Spectrophotometers
m o l e c u l a r s p e c t r o s c o p y Thermo Scientific GENESYS 10S Series UV-Visible Spectrophotometers Powerful Performance, Affordable Price Accurate Reliable Easy-to-Use Part of Thermo Fisher Scientific
Coating Thickness and Composition Analysis by Micro-EDXRF
Application Note: XRF Coating Thickness and Composition Analysis by Micro-EDXRF www.edax.com Coating Thickness and Composition Analysis by Micro-EDXRF Introduction: The use of coatings in the modern manufacturing
Micro Motion 3098 Gas Specific Gravity Meter
Product Data Sheet PS-001161, Rev. D April 2013 Micro Motion 3098 Gas Specific Gravity Meter Micro Motion density and concentration meters are built to tackle the most demanding process and fiscal applications.
INTERNATIONAL OLIVE COUNCIL
INTERNATIONAL OLIVE COUNCIL COI/T.20/Doc. No 19/Rev. 3 February 2015 ENGLISH Original: ENGLISH Príncipe de Vergara, 154 28002 Madrid España Telef.: +34 915 903 638 Fax: +34 915 631 263 - e-mail: [email protected]
Lab #11: Determination of a Chemical Equilibrium Constant
Lab #11: Determination of a Chemical Equilibrium Constant Objectives: 1. Determine the equilibrium constant of the formation of the thiocyanatoiron (III) ions. 2. Understand the application of using a
What s in the Mix? Liquid Color Spectroscopy Lab (Randy Landsberg & Bill Fisher)
What s in the Mix? Liquid Color Spectroscopy Lab (Randy Landsberg & Bill Fisher) Introduction: There is more to a color than a name. Color can tell us lots of information. In this lab you will use a spectrophotometer
Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy
Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy Application Note RF & Microwave Spectrum Analyzers Table of Contents 3 3 4 4 5 7 8 8 13 13 14 16 16 Introduction Absolute versus relative
Encoders for Linear Motors in the Electronics Industry
Technical Information Encoders for Linear Motors in the Electronics Industry The semiconductor industry and automation technology increasingly require more precise and faster machines in order to satisfy
DMA-1 Direct Mercury Analyzer
DMA-1 Direct Mercury Analyzer www.milestonesrl.com MILESTONE H E L P I N G C H E M I S T S 8 good reasons to choose the milestone DmA-1 1. no sample preparation 2. ease of use 3. lowest cost of analysis
2 Spectrophotometry and the Analysis of Riboflavin
2 Spectrophotometry and the Analysis of Riboflavin Objectives: A) To become familiar with operating the Platereader; B) to learn how to use the Platereader in determining the absorption spectrum of a compound
International Year of Light 2015 Tech-Talks BREGENZ: Mehmet Arik Well-Being in Office Applications Light Measurement & Quality Parameters
www.led-professional.com ISSN 1993-890X Trends & Technologies for Future Lighting Solutions ReviewJan/Feb 2015 Issue LpR 47 International Year of Light 2015 Tech-Talks BREGENZ: Mehmet Arik Well-Being in
