SGS: Das Scanning Grating Spektrometer Ein kleines, günstiges Spektrometermodul auf Basis eines dispersiven Mikrosystems
|
|
- Katrina Powers
- 8 years ago
- Views:
Transcription
1 the leading supplier of Micro Scanning Devices Your Micro Optical Solution IPHT-Workshop We move the light for you! SGS: Das Scanning Grating Spektrometer Ein kleines, günstiges Spektrometermodul auf Basis eines dispersiven Mikrosystems Dr. Alexander Wolter Alexander Wolter, 11-Mar-08, Page 1
2 Company HiperScan GmbH, Dresden develops, fabricates and sells High-Tech-solutions made of microsystems Innovator 10 years experience in MEMS proved production technology strong partners for our customers OEM Industry So you can offer your customers new products more quality better performance Alexander Wolter, 11-Mar-08, Page 2
3 Our SGS product line offers outstanding near infrared-spectrometers compact dimensions short measurement time integrated computing power reliable technology best return on investment all through Scanning Grating technology Alexander Wolter, 11-Mar-08, Page 3
4 Spectroscopy Infrared-spectroscopy non-destructive analysis method identifies many chemical substances quantifies blends and mixtures provides a universal method quick results high reproducibility Alexander Wolter, 11-Mar-08, Page 4
5 Spectroscopy For quality control Incoming inspection Process analysis Process control outgoing inspection Alexander Wolter, 11-Mar-08, Page 5
6 Spectroscopy For all industries, especially Food Feed Beverage Agriculture Chemical production Oil & petro Recycling Pharmaceuticals Life Science Bio Tech Alexander Wolter, 11-Mar-08, Page 6
7 Spectrometry Products: SGS1900 & SGS2500 Universal & flexible continuous spectra with a broad spectral range up to 1900nm (!) or 2500nm at 3-10nm resolution Compact & low-power also with cooled detector 3 Software-Interfaces applicable to all NIR-active substances (Analysis of the 1st & 2nd overtones) to fit into every device implementation into any proprietary software Alexander Wolter, 11-Mar-08, Page 7
8 Spectrometry Products : SGS1900 & SGS2500 High quality Precision due to MEMS with internal time-reference for reproducible analysis results Robust according to specifications for mobile applications long-term durability (no bearings, no wear) No linear detector array For building maintainance-free and reliable devices reliable shipping times selected detectors & better price Alexander Wolter, 11-Mar-08, Page 8
9 Diode Array Spectrometers InGaAs diode array expensive ($2.000-$8.000) entrance slit Technical Background: State of the Art fixed diffraction grating Czerny-Turner- Monochromator Grating on rotational stage heavy slow vibration sensitive expensive entrance slit rotating grating spectrum scanned spectrum collimator diode array collimator exit slit single detector Alexander Wolter, 11-Mar-08, Page 9
10 Micro Scanning Devices Innovation through high precision high speed high reliability Alexander Wolter, 11-Mar-08, Page 10
11 Technical Background MEMS scanning gratings fabrication on silicon wafers including the grating dicing & packaging alignment in the optical bench Alexander Wolter, 11-Mar-08, Page 11
12 Technical Background Combines the advantages of microsystems highly robust, almost no weight vibration tolerant, almost no inertia durable, no wear tiny quick entrance slit collimator Scanning Grating exit slit scanned spectrum single detector and of the Czerny-Turner monochromator single detector with optimized amplifier broad & continuous spectral range limited computed power required Alexander Wolter, 11-Mar-08, Page 12
13 Specific advantages Advantages of the specific microsystem absolutely symmetric dimensions & drive insensitive to vibration resonant operation highly reproducible position no need for analog real-time position sensing control in time-domain (high resolution) Alexander Wolter, 11-Mar-08, Page 13
14 The SGS-series of NIR-spectrometers Technical data SGS 1900 SGS1900 SGS2500 comment spectral range nm nm other configurations resolution <10 nm <13 nm optional 3 nm wavelength stability 1 nm straylight < 0,1 % acqusition time detector dimensions, weight InGaAs uncooled 10 ms InGaAs 2-stage TE-cooled SMA 905 for low-oh-fiber with 400µm core USB 100 mm x 80 mm x 75 mm, 800 g Alexander Wolter, 11-Mar-08, Page 14
15 Technical Background Alexander Wolter, 11-Mar-08, Page 15
16 Technical Background Alexander Wolter, 11-Mar-08, Page 16
17 Technical Background Alexander Wolter, 11-Mar-08, Page 17
18 NIR-Spectrometer Start today with the technology of tomorrow! Fraunhofer Technology 10 years of experience in our MEMS-technology 5 years of experience in our spectrometers We keep innovating for your future success and the success of your customers! Alexander Wolter, 11-Mar-08, Page 18
Spectral Measurement Solutions for Industry and Research
Spectral Measurement Solutions for Industry and Research Hamamatsu Photonics offers a comprehensive range of products for spectroscopic applications, covering the, Visible and Infrared regions for Industrial,
More informationMB3600 Versatile FT-NIR analyzer designed for your industry The most reliable FT-NIR specifically designed for QA/QC
Measurement & Analytics Measurement made easy MB3600 Versatile FT-NIR analyzer designed for your industry The most reliable FT-NIR specifically designed for QA/QC MB3600 FT-NIR spectrometer for your industry
More informationNederland België / Belgique
Cronus Brochure 2 Introduction Cronus: The first spectrometer and colorimeter in one The Cronus is world s first spectrocolorimeter combining a high en VIS spectrometer with a high speed XYZ colorimeter.
More informationAgilent Cary 4000/5000/6000i Series UV-Vis-NIR
Agilent Cary 4000/5000/6000i Series UV-Vis-NIR Guaranteed specifications Design overview Double beam, ratio recording, double out-of-plane Littrow monochromator UV-Vis-NIR spectrophotometer (Agilent Cary
More informationS2000 Spectrometer Data Sheet
Description The Ocean Optics OEM S2000 Spectrometer includes the linear CCD-array optical bench, plus the circuits necessary for spectrometer operation. The result is a compact, flexible system with no
More informationFig.1. The DAWN spacecraft
Introduction Optical calibration of the DAWN framing cameras G. Abraham,G. Kovacs, B. Nagy Department of Mechatronics, Optics and Engineering Informatics Budapest University of Technology and Economics
More informationSingle Mode Fiber Lasers
Single Mode Fiber Lasers for Industrial and Scientific Applications T h e P o w e r t o T r a n s f o r m T M IPG s Single Mode Fiber Lasers Advantages IPG's YLR-SM Series represents a break-through generation
More informationPassive Remote Sensing of Clouds from Airborne Platforms
Passive Remote Sensing of Clouds from Airborne Platforms Why airborne measurements? My instrument: the Solar Spectral Flux Radiometer (SSFR) Some spectrometry/radiometry basics How can we infer cloud properties
More informationAutomatisierte, hochpräzise Optikmontage Lösungen für die Industrie
Automatisierte, hochpräzise Optikmontage Lösungen für die Industrie Alexander Steinecker, CSEM Trends in Micro Nano, HSLU, Horw, 5. Dezember 2013 High power laser sources Motivation Laser manufacturing
More informationDevelopment of the Extreme Ultraviolet Spectrometer: EXCEED
Development of the Extreme Ultraviolet Spectrometer: EXCEED Go Murakami*, Kazuo Yoshioka, Atsushi Yamazaki, Tomoki Kimura Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency
More informationEncoders for Linear Motors in the Electronics Industry
Technical Information Encoders for Linear Motors in the Electronics Industry The semiconductor industry and automation technology increasingly require more precise and faster machines in order to satisfy
More informationSpectraTec II. Polarized Multi-Laser Source BLUE SKY RESEARCH WAVELENGTHS. The SpectraTec II
BLUE SKY RESEARCH The SpectraTec II, two wavelength laser module is a highly integrated system comprised of two lasers, individual driving and temperature control electronics, wavelength combining, and
More informationCorona process The new ZEISS spectrometer system for the food industry
Interactive PDF Version 1.0 Start Trust needs reliability quality needs ZEISS The real challenge is to offer a product with consistent quality using raw materials which are themselves subject to ongoing
More informationWAVELENGTH OF LIGHT - DIFFRACTION GRATING
PURPOSE In this experiment we will use the diffraction grating and the spectrometer to measure wavelengths in the mercury spectrum. THEORY A diffraction grating is essentially a series of parallel equidistant
More informationIntroduction to Fourier Transform Infrared Spectrometry
Introduction to Fourier Transform Infrared Spectrometry What is FT-IR? I N T R O D U C T I O N FT-IR stands for Fourier Transform InfraRed, the preferred method of infrared spectroscopy. In infrared spectroscopy,
More informationNano-Spectroscopy. Solutions AFM-Raman, TERS, NSOM Chemical imaging at the nanoscale
Nano-Spectroscopy Solutions AFM-Raman, TERS, NSOM Chemical imaging at the nanoscale Since its introduction in the early 80 s, Scanning Probe Microscopy (SPM) has quickly made nanoscale imaging an affordable
More informationAgilent Cary 60 UV-Vis
Agilent Cary 60 UV-Vis Efficient. Accurate. Flexible. Specifications Introduction The Agilent Cary 60 UV-Vis spectrophotometer is efficient, accurate and flexible, and is designed to meet both current
More informationLaser Diode Gas Sensors
Laser Diode Gas Sensors Photonic Sensors Swiss Laser Net Workshop Biel 17.09.09 Thomas Hessler Overview Leister and ist photonic activities TDLS detection principle TDLS product plattform Applications
More informationModern Classical Optics
Modern Classical Optics GEOFFREY BROOKER Department of Physics University of Oxford OXPORD UNIVERSITY PRESS Contents 1 Electromagnetism and basic optics 1 1.1 Introduction 1 1.2 The Maxwell equations 1
More informationinstruments Analytical Instruments for Science
instruments Analytical Instruments for Science instruments Contents PAGE NO. Introduction 4 T60 UV-Vis Spectrophotometer 6 T70 UV-Vis Spectrophotometer 10 T80 UV-Vis Spectrophotometer 14 T90+ UV-Vis Spectrophotometer
More informationAnalyze IQ Spectra Manager Version 1.2
Analyze IQ Spectra Manager Version 1.2 User Manual Document Version: 1.2-2010-02-15 Copyright Analyze IQ Limited, 2008-2010. All Rights Reserved. Table of Contents 1 Introduction... 3 2 Installation...
More informationRadiant Dyes Laser Accessories GmbH
New NarrowScan New Resonator Design Improved Sine Drive Unit Autotracking Frequency doubling, tripling and mixing Wavelength Separation Unit Frequency Stabilization Temperature Stabilization Wavelength
More informationFTIR Instrumentation
FTIR Instrumentation Adopted from the FTIR lab instruction by H.-N. Hsieh, New Jersey Institute of Technology: http://www-ec.njit.edu/~hsieh/ene669/ftir.html 1. IR Instrumentation Two types of instrumentation
More informationO6: The Diffraction Grating Spectrometer
2B30: PRACTICAL ASTROPHYSICS FORMAL REPORT: O6: The Diffraction Grating Spectrometer Adam Hill Lab partner: G. Evans Tutor: Dr. Peter Storey 1 Abstract The calibration of a diffraction grating spectrometer
More informationRaman spectroscopy Lecture
Raman spectroscopy Lecture Licentiate course in measurement science and technology Spring 2008 10.04.2008 Antti Kivioja Contents - Introduction - What is Raman spectroscopy? - The theory of Raman spectroscopy
More informationSpherical Beam Volume Holograms Recorded in Reflection Geometry for Diffuse Source Spectroscopy
Spherical Beam Volume Holograms Recorded in Reflection Geometry for Diffuse Source Spectroscopy Sundeep Jolly A Proposal Presented to the Academic Faculty in Partial Fulfillment of the Requirements for
More informationwww.photonics.com May 2013 Color Sense Trilinear Cameras Bring Speed, Quality
www.photonics.com May 2013 Color Sense Trilinear Cameras Bring Speed, Quality Tech Feature Trilinear Cameras Offer High-Speed Color Imaging Solutions With high color quality and speed and low cost trilinear
More informationZEISS T-SCAN Automated / COMET Automated 3D Digitizing - Laserscanning / Fringe Projection Automated solutions for efficient 3D data capture
ZEISS T-SCAN Automated / COMET Automated 3D Digitizing - Laserscanning / Fringe Projection Automated solutions for efficient 3D data capture ZEISS 3D Digitizing Automated solutions for efficient 3D data
More informationMeasurement & Analytics Measurement made easy
Measurement & Analytics Measurement made easy MB3600-PH Versatile FT-NIR analyzer for the life sciences and pharmaceutical industries Designed for QA/QC, research and development and at-line PAT applications
More informationWavelength stabilized high-power diode laser modules
Wavelength stabilized high-power diode laser modules Bernd Köhler *, Thomas Brand, Matthias Haag, Jens Biesenbach DILAS Diodenlaser GmbH, Galileo-Galilei-Str. 10, 55129 Mainz-Hechtsheim, Germany ABSTRACT
More informationRecent developments in high bandwidth optical interconnects. Brian Corbett. www.tyndall.ie
Recent developments in high bandwidth optical interconnects Brian Corbett Outline Introduction to photonics for interconnections Polymeric waveguides and the Firefly project Silicon on insulator (SOI)
More informationFiber Optics: Engineering from Global to Nanometer Dimensions
Fiber Optics: Engineering from Global to Nanometer Dimensions Prof. Craig Armiento Fall 2003 1 Optical Fiber Communications What is it? Transmission of information using light over an optical fiber Why
More informationMachine Tool Inspection & Analyzer solutions
Machine Tool Inspection & Analyzer solutions Introduction IBS Precision Engineering machine tool inspection series offers a range of products to provide peace of mind and control to machine operators by
More informationAmplified High Speed Fiber Photodetectors
Amplified High Speed Fiber Photodetectors User Guide (800)697-6782 sales@eotech.com www.eotech.com Page 1 of 7 EOT AMPLIFIED HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE Thank you for purchasing your Amplified
More informationSFG spectrometers. Sum Frequency Generation Vibrational Spectroscopy. More than 20 years experience
Sum Frequency Generation Vibrational Spectroscopy More than 20 years experience Sum Frequency Generation Vibrational Spectroscopy Sum Frequency Generation Vibrational Spectroscopy (SFG-VS) is powerful
More informationLabRAM HR. Research Raman Made Easy! Raman Spectroscopy Systems. Spectroscopy Suite. Powered by:
LabRAM HR Research Raman Made Easy! Raman Spectroscopy Systems Powered by: Spectroscopy Suite Cutting-Edge Applications with the LabRAM HR Deeply involved in Raman spectroscopy for decades, HORIBA Scientific
More informationUV-VIS-NIR. Varian Cary 4000, 5000 and 6000i Spectrophotometers
UV-VIS-NIR Varian Cary 4000, 5000 and 6000i Spectrophotometers Varian Cary At the leading edge Varian s Cary range of UV-Vis-NIR spectrophotometers has been synonymous with excellence and high performance
More informationDIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES)
Features: DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES) PATENT NUMBERS: CANADA 2,494,133, USA 7095931, 7295731 AND CHINA 1672073 Telcordia GR-468 qualified Available in versions for any wavelength
More informationRaman Spectroscopy Basics
Raman Spectroscopy Basics Introduction Raman spectroscopy is a spectroscopic technique based on inelastic scattering of monochromatic light, usually from a laser source. Inelastic scattering means that
More informationCoating Thickness and Composition Analysis by Micro-EDXRF
Application Note: XRF Coating Thickness and Composition Analysis by Micro-EDXRF www.edax.com Coating Thickness and Composition Analysis by Micro-EDXRF Introduction: The use of coatings in the modern manufacturing
More informationAnalysis of Chlorine, Bromine and Iodine in Water using ICP-AES
ICP OPTICAL ATOMIC EMISSION SPECTROSCOPY Analysis of Chlorine, Bromine and Iodine in Water using ICP-AES HORIBA Scientific Longjumeau, France Keywords: metallurgy, non-ferrous, halogens 1 Introduction
More informationDepartment of Aerospace Engineering Indian Institute of Science Bangalore
Department of Aerospace Engineering Indian Institute of Science Bangalore Brief Outline of Department The department of Aerospace Engineering is one of the oldest departments in the country encompassing
More informationIntroduction to reflective aberration corrected holographic diffraction gratings
Introduction to reflective aberration corrected holographic diffraction gratings By Steve Slutter, Wu Jiang, and Olivier Nicolle The reflective diffraction grating is the heart of most spectroscopy systems
More informationHerschel PACS Test Procedure STM PACS-KT-PR-011 Issue: 1 Revision: -
CASE GmbH Westendstrasse 125 80339 München Herschel PACS Test Procedure STM 1 Revision: - i Document Approval Sheet Title: Herschel PACS Subtitle: Test Procedure STM Doc. No: 1 Revision: - Prepared:......
More informationAMPLIFIED HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE
AMPLIFIED HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE Thank you for purchasing your Amplified High Speed Fiber Photodetector. This user s guide will help answer any questions you may have regarding the
More informationIndustrial Process Monitoring Requires Rugged AOTF Tools
Industrial Process Monitoring Requires Rugged AOTF Tools Dr Jolanta Soos Growth has been rapid in the use of spectroscopic methods to monitor industrial processes, both in production lines and for quality
More informationMEMS mirror for low cost laser scanners. Ulrich Hofmann
MEMS mirror for low cost laser scanners Ulrich Hofmann Outline Introduction Optical concept of the LIDAR laser scanner MEMS mirror requirements MEMS mirror concept, simulation and design fabrication process
More informationSilicon Drift Detector Product Brochure Update 2013
Silicon Drift Detector Product Brochure Update 2013 Content Classic Silicon Drift Detector High Resolution Silicon Drift Detector Multielement Silicon Detector Extra Large Detector Series July 2013 About
More informationA NEW LOOK AT RISLEY PRISMS. By Craig Schwarze Senior Systems Engineer OPTRA Inc.
As seen in Photonics Spectra June 2006: A NEW LOOK AT RISLEY PRISMS By Craig Schwarze Senior Systems Engineer OPTRA Inc. Introduction With laser beams finding more and more applications that require aiming
More informationFlame Direct Attach UV-VIS Integrated Sampling System Installation and Operation Instructions
Flame Direct Attach UV-VIS Integrated Sampling System Installation and Operation Instructions Description The Flame Integrated Sampling System (FLAME-DA-CUV-UV-VIS) is a snap-on, direct-attach 1 cm cuvette
More informationInspection and Illumination Systems for Visual Quality Assurance. Large selection Attractive prices Tailored solutions. optometron.
Inspection and Illumination Systems for Visual Quality Assurance Large selection Attractive prices Tailored solutions optometron.de en Optometron fulfils a key role Visual quality assurance is essential
More informationAppendix 5 Overview of requirements in English
Appendix 5 Overview of requirements in English This document is a translation of Appendix 4 (Bilag 4) section 2. This translation is meant as a service for the bidder and in case of any differences between
More informationMobile field balancing reduces vibrations in energy and power plants. Published in VGB PowerTech 07/2012
Mobile field balancing reduces vibrations in energy and power plants Published in VGB PowerTech 07/2012 Dr. Edwin Becker PRÜFTECHNIK Condition Monitoring PRÜFTECHNIK Condition Monitoring GmbH 85737 Ismaning
More informationFully Automated Imaging Spectrometer User Manual
Fully Automated Imaging Spectrometer User Manual Part Number 81092 Revision 2 Copyright February, 06 HORIBA Jobin Yvon Inc., Optical Spectroscopy Division. All rights reserved. Portions of the software
More information5. Scanning Near-Field Optical Microscopy 5.1. Resolution of conventional optical microscopy
5. Scanning Near-Field Optical Microscopy 5.1. Resolution of conventional optical microscopy Resolution of optical microscope is limited by diffraction. Light going through an aperture makes diffraction
More informationMB3000-PH FT-IR spectrometer for the pharmaceutical industry Designed for QA/QC, formulation, research and development laboratory applications
Measurement & Analytics Measurement made easy MB3000-PH FT-IR spectrometer for the pharmaceutical industry Designed for QA/QC, formulation, research and development laboratory applications MB3000-PH FT-IR
More informationSpecifying Plasma Deposited Hard Coated Optical Thin Film Filters. Alluxa Engineering Staff
Specifying Plasma Deposited Hard Coated Optical Thin Film Filters. Alluxa Engineering Staff December 2012 Specifying Advanced Plasma Deposited Hard Coated Optical Bandpass and Dichroic Filters. Introduction
More informationThermo Scientific Dionex UltiMate 3000 Variable Wavelength Detectors
Chromatography Thermo Scientific Dionex UltiMate 3000 Variable Wavelength Detectors Product Specifications Integrating hardware, software and separation chemistry, we offer UHPLC to everyone for all needs
More informationBarcode positioning systems BPS 8, BPS 34/37 Innovations that truly move you forwards.
Barcode positioning systems BPS 8, BPS 34/37 Innovations that truly move you forwards. PRODUCT INFORMATION Flexible, tolerant and millimetre precision. The Leuze electronic barcode positioning system.
More information3D TOPOGRAPHY & IMAGE OVERLAY OF PRINTED CIRCUIT BOARD ASSEMBLY
3D TOPOGRAPHY & IMAGE OVERLAY OF PRINTED CIRCUIT BOARD ASSEMBLY Prepared by Duanjie Li, PhD & Andrea Novitsky 6 Morgan, Ste156, Irvine CA 92618 P: 949.461.9292 F: 949.461.9232 nanovea.com Today's standard
More informationUniSort NIR Technologies
The first near infra-red (NIR) sorting systems were used to process recyclable materials in the early 1990s. Until then, recyclable materials were only collected sporadically, and sorted more or less by
More informationSepye SeptembMay 2015- Volume 3, Issue 1 In This Issue Thank You for Your Feedback NEW! Detective-Remote V3 NEW! Mobile MCB Server NEW! Detective-Pro NEW! Programmer's Toolkit NEW! M-1-T-2 Tripod NEW!
More informationSense it! Connect it! Bus it! Solve it! EncoderS
Sense it! Connect it! Bus it! Solve it! EncoderS Incremental encoders Incremental encoders use electrical pulses to measure rotation speed or position. The dual-channel incremental encoders of the Ri series,
More informationLaboratory #3 Guide: Optical and Electrical Properties of Transparent Conductors -- September 23, 2014
Laboratory #3 Guide: Optical and Electrical Properties of Transparent Conductors -- September 23, 2014 Introduction Following our previous lab exercises, you now have the skills and understanding to control
More informationLabRAM HR Evolution. Research Raman Made Easy!
LabRAM HR Evolution Research Raman Made Easy! Cutting-Edge Applications with the LabRAM HR LabRAM HR Deeply involved in Raman spectroscopy for decades, HORIBA Scientific has been providing an extensive
More informationSpectrometers. Introduction Fiber Optic Spectroscopy. Optical Bench Design. info@avantes.com www.avantes.com. Figure 1 Optical bench design
Introduction Fiber Optic Spectroscopy Optical spectroscopy is a technique for measuring light intensity in the UV-, VIS-, NIR- and IR-region. Spectroscopic measurements are being used in many different
More informationExperiment #5: Qualitative Absorption Spectroscopy
Experiment #5: Qualitative Absorption Spectroscopy One of the most important areas in the field of analytical chemistry is that of spectroscopy. In general terms, spectroscopy deals with the interactions
More informationInternational Year of Light 2015 Tech-Talks BREGENZ: Mehmet Arik Well-Being in Office Applications Light Measurement & Quality Parameters
www.led-professional.com ISSN 1993-890X Trends & Technologies for Future Lighting Solutions ReviewJan/Feb 2015 Issue LpR 47 International Year of Light 2015 Tech-Talks BREGENZ: Mehmet Arik Well-Being in
More informationMicro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity
Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Innovation with Integrity Micro-CT 3D Microscopy Using Micro-CT for SEM Micro-CT for SEM
More informationZEISS Axiocam 506 color Your Microscope Camera for Imaging of Large Sample Areas Fast, in True Color, and High Resolution
Product Information Version 1.0 ZEISS Axiocam 506 color Your Microscope Camera for Imaging of Large Sample Areas Fast, in True Color, and High Resolution ZEISS Axiocam 506 color Sensor Model Sensor Pixel
More informationSimplicity. Reliability. Performance
Simplicity Reliability Performance ICP Without Compromise At Teledyne Leeman Labs atomic spectroscopy is our business, our only business. We are deeply committed to providing you with technically superior
More informationMore colors, more power, more applications... Solid state laser Diode laser Line laser Multicolor laser Laser diode driver Cooling modules
PEGASUS Linienlaser Diodenlaser Festkörperlaser PEGASUS LASERSYSTEME GMBH More colors, more power, more applications... Solid state laser Diode laser Line laser Multicolor laser Laser diode driver Cooling
More informationNear infrared spectroscopy as a tool for in-line control of process and material properties of PLA biopolymers
Near infrared spectroscopy as a tool for in-line control of process and material properties of PLA biopolymers OMC conference Karlsruhe 18.3-19.3.2015 W. Becker Fraunhofer Institute for Chemical Technology
More informationBiaxial tripod MEMS mirror and omnidirectional lens for a low cost wide angle laser range sensor
Biaxial tripod MEMS mirror and omnidirectional lens for a low cost wide angle laser range sensor U. Hofmann, Fraunhofer ISIT Itzehoe M. Aikio, VTT Finland Abstract Low cost laser scanners for environment
More informationGuideline Laser Series
Guideline Laser Series Highly visible alignment laser for visually demanding surfaces Red / Green long visible lines Equal brightness across length of the line Uniform Line (no fading at ends of the line)
More informationGRID AND PRISM SPECTROMETERS
FYSA230/2 GRID AND PRISM SPECTROMETERS 1. Introduction Electromagnetic radiation (e.g. visible light) experiences reflection, refraction, interference and diffraction phenomena when entering and passing
More informationMB3600-HP12 / Measurement & Analytics. Laboratory FT-NIR Heavy Oils Analyzer Crude oil, fuel oil, heavy oil upgrader unit feeds
MB3600-HP12 / Measurement & Analytics Laboratory FT-NIR Heavy Oils Analyzer Crude oil, fuel oil, heavy oil upgrader unit feeds Adapted for crude oil, fuel oil and heavy oil upgrader unit feed applications
More informationINFRARED PARTS MANUAL
INFRARED PARTS MANUAL PIR325 FL65 GLOLAB CORPORATION Thank you for buying our Pyroelectric Infrared components. The goal of Glolab is to produce top quality electronic kits, products and components. All
More informationAdvanced Research Raman System Raman Spectroscopy Systems
T600 Advanced Research Raman System Raman Spectroscopy Systems T600 Advanced Research Raman System T600 Triple stage Raman Spectrometer: The only solution for unprecedented stability and performance! Robust
More informationMeasuring of optical output and attenuation
Measuring of optical output and attenuation THEORY Measuring of optical output is the fundamental part of measuring in optoelectronics. The importance of an optical power meter can be compared to an ammeter
More informationA down-under undergraduate optics and photonics laboratory
A down-under undergraduate optics and photonics laboratory Barry Perczuk and Michael Gal School of Physics, The University of New South Wales, Sydney, NSW 2052, Australia ABSTRACT Our senior undergraduate
More informationSpectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs
Spectroscopy Biogeochemical Methods OCN 633 Rebecca Briggs Definitions of Spectrometry Defined by the method used to prepare the sample 1. Optical spectrometry Elements are converted to gaseous atoms or
More informationMACHINE VISION FOR SMARTPHONES. Essential machine vision camera requirements to fulfill the needs of our society
MACHINE VISION FOR SMARTPHONES Essential machine vision camera requirements to fulfill the needs of our society INTRODUCTION With changes in our society, there is an increased demand in stateof-the art
More informationINSTRUCTION MANUAL. Model 207 Scanning Monochromator
INSTRUCTION MANUAL Model 207 Scanning Monochromator Serial Number: A Schoeffel Group Company 7A Stuart Road Chelmsford, Massachusetts 01824 PHONE: 978-256-4512 / 1-800-255-1055 FAX: 978-250-8625 EMAIL:
More informationMCAL Spectrophotometry. Spectrophotometry
MCAL Spectrophotometry Instruments include: Cary 50 UV-vis Spectrophotometer Eclipse Spectrofluorometer HPLC Diode Array and Fluorescence ICP-OES with CCD detection Spectrophotometry The instruments all
More information1 Laboratory #5: Grating Spectrometer
SIMG-215-20061: LABORATORY #5 1 Laboratory #5: Grating Spectrometer 1.1 Objective: To observe and measure the spectra of different light sources. 1.2 Materials: 1. OSA optics kit. 2. Nikon digital camera
More informationTube Control Measurement, Sorting Modular System for Glass Tube
Tube Control Measurement, Sorting Modular System for Glass Tube Tube Control is a modular designed system of settled instruments and modules. It comprises measuring instruments for the tube dimensions,
More informationUses of Derivative Spectroscopy
Uses of Derivative Spectroscopy Application Note UV-Visible Spectroscopy Anthony J. Owen Derivative spectroscopy uses first or higher derivatives of absorbance with respect to wavelength for qualitative
More informationMotion and Positioning
Motion and Positioning The Broadest and Deepest Portfolio WWW.PI.ws Technology The Broadest and Deepest Portfolio Core Technologies n Piezo components, actuators and motors n Magnetic drives n Guiding
More informationQualitative NIR Analysis for Ingredients in the Baking Industry
Overview The challenge to all baking companies in today s economy is to operate plants as efficiently as possible, with a focus on quality and keeping costs in check. With regulatory issues becoming more
More informationThermal Flow Sensor Die
Microsystems, Inc. Thermal Flow Sensor Die Description Posifa s Thermal Flow Sensor Die measures the flow of a liquid or gaseous medium across the surface of the die using the Thermotransfer (Calorimetric)
More informationDETECTION OF SUBSURFACE DAMAGE IN OPTICAL TRANSPARENT MATERIALSS USING SHORT COHERENCE TOMOGRAPHY. Rainer Boerret, Dominik Wiedemann, Andreas Kelm
URN (Paper): urn:nbn:de:gbv:ilm1-2014iwk-199:0 58 th ILMENAU SCIENTIFIC COLLOQUIUM Technische Universität Ilmenau, 08 12 September 2014 URN: urn:nbn:de:gbv:ilm1-2014iwk:3 DETECTION OF SUBSURFACE DAMAGE
More informationArtisan Technology Group is your source for quality new and certified-used/pre-owned equipment
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED
More informationPhysics 441/2: Transmission Electron Microscope
Physics 441/2: Transmission Electron Microscope Introduction In this experiment we will explore the use of transmission electron microscopy (TEM) to take us into the world of ultrasmall structures. This
More informationMeasurement of Enhanced Specular Reflector (ESR) Films Using a LAMBDA 1050 UV/Vis/NIR Spectrometer and URA Accessory
FIELD APPLICATION REPORT UV/Vis/NIR Spectroscopy Author: Frank Padera Shelton, CT Contributor: Chris Lynch Shelton, CT Measurement of Enhanced Specular Reflector (ESR) Films Using a LAMBDA 1050 UV/Vis/NIR
More informationExperiment 5. Lasers and laser mode structure
Northeastern University, PHYS5318 Spring 2014, 1 1. Introduction Experiment 5. Lasers and laser mode structure The laser is a very important optical tool that has found widespread use in science and industry,
More informationMikro-Tasarım Next Generation Imaging Sensors
Mikro-Tasarım Next Generation Imaging Sensors NIR SWIR High- Performance ROICs, Sensors, and ASICs for Infrared Imaging Systems LWIR Mikro- Tasarım was founded in 2008 as a fabless semiconductor IC design
More informationUSB2000 Fiber Optic Spectrometer. Installation and Operation Manual Document Number 170-00000-000-02-1005
USB2000 Fiber Optic Spectrometer Installation and Operation Manual Document Number 170-00000-000-02-1005 Offices: Ocean Optics, Inc. 830 Douglas Ave., Dunedin, FL., USA 34698 Phone 727.733.2447 Fax 727.733.3962
More informationTime out states and transitions
Time out states and transitions Spectroscopy transitions between energy states of a molecule excited by absorption or emission of a photon hn = DE = E i - E f Energy levels due to interactions between
More information