Graphical User Interface Capabilities of MATLAB in Centralized Failure Detection System (CFDS)
|
|
|
- Caroline Dickerson
- 10 years ago
- Views:
Transcription
1 INTERNATIONAL JOURNAL OF MICROWAVE AND OPTICAL TECHNOLOGY 128 Graphical User Interface Capabilities of MATLAB in Centralized Failure Detection System (CFDS) Mohammad Syuhaimi Ab-Rahman* and Boonchuan Ng Computer & Network Security Research Group Department of Electrical, Electronics & Systems Engineering, Faculty of Engineering & Built Environment Universiti Kebangsaan Malaysia, UKM Bangi, Selangor, Malaysia Tel: ; Fax: ; Abstract - This paper proposed a MATLAB-based graphical user interface (GUI) development named as Centralized Failure Detection System (CFDS) to increase the efficiency, survivability, and reliability of -to-the-home (FTTH) customer access network. This program will be installed with optical line terminal (OLT) at central office (CO) to monitor the network system and identify any fault that occurs in FTTH downwardly from CO towards residential customer locations. Conventionally, optical time domain reflectometer (OTDR) is used to localize any fault in FTTH upwardly from customer residential location towards CO. However, OTDR can only display a result of a testing line in a time, which tends to time consuming. The usage of passive optical splitter in FTTH with point-to-multipoint (P2MP) configuration is blocking the reflected signal that need to be analyzed by OTDR. Therefore, it becomes a hindrance to detect any faulty with a large number of subscribers and large coverage area downwardly in the plant between the optical splitter and multiple optical network units (ONUs) at different customer residential locations by using OTDR. Thus the troubleshooting work become very complex and leads to increase the maintenance cost. CFDS is interfaced with OTDR to accumulate every network testing result to be displayed on a single computer screen for further analysis. Index Terms - Survivability, reliability, FTTH, P2MP configuration, fault. I. INTRODUCTION FTTH is an end-to-end optical connection for the deployment of high speed broadband services to homes. FTTH technology is specifically with its bandwidth capacity, reliability, security, and scalability as well as cost effective. The network service providers deliver triple-play (data, audio, and video) services from CO (or network operation center/local exchange) to multiple subscribers/customer premises at different customer residential locations over a sharing (feeder ) in a passive optical network (PON) architecture with tree topology or P2MP configuration, where the distance between OLT and ONUs can be up to 20 km in this architecture. A passive optical splitter (branching device) is used to connect the feeder (sharing ) to multiple drop s at remote node (RN) [1]. Due to the large transport capacity achieved by optical access network, failures caused huge losses of data and greatly influence upon a large number of users over a wide area. Besides, the laser light (optical source) used in optical communication systems may explore at the break point, it can cause burning in the retina that lead to damage temporarily or permanently (blind) in a few seconds or even less time depending to the energy absorbed by the retina. Therefore, the survivability of the whole network has to be examined more seriously [2]. OTDR is the most costly equipment among the optical testing equipments, but it is most frequently used for characterizing a long haul communication link. According to Chomycz [3], OTDR testing is the best method for determining the exact location of broken optical s in an installed optical cable when the cable jacket
2 INTERNATIONAL JOURNAL OF MICROWAVE AND OPTICAL TECHNOLOGY 129 is not visibly damaged. A high intensity optical pulse is launched into an optical line and a high speed optical detector recorded and graphically displays the observed reflection in the screen. User can observe losses due to splice, break, connector, and other attenuation in the optical line from the visual representation on OTDR's screen. II. OPERATIONAL PRINCIPLES OF CFDS CFDS is a centralized control and surveillance system that provide the FTTH network service providers with a means of viewing traffic flow and detecting any breakdowns as well as other circumstances which may require some promptly actions. The developed program also provides the network service providers with a control function to intercom all subscribers with CO. The working principles of CFDS are structured into three main parts to support its operations: (i) Optical line measurement with OTDR, (ii) Interfacing personal computer (PC) with OTDR, and (iii) Advanced data analyzing with CFDS. The whole operating process can be simplified in the flow chart as depicted in Fig.1. Our system architecture design is presented in Fig.2. The maximum distance between the OLT and ONUs is 20 km. A commercially available OTDR with a 1625 nm laser source is used for failure detection control and in-service troubleshooting without affecting the triple-play services transmission. The OTDR is connected to a PC or laptop to display the troubleshooting results via RS-232 (Serial port) connection. The triple-play signals (operating wavelengths; 1310 nm, 1490 nm, and 1550 nm) are multiplexed with 1625 nm testing signal. When four kinds of signals are distributed, the 1625 nm testing signal will be split up by wavelength selective coupler (WSC), which is installed before the optical splitter. The WSC only allow the 1625 nm testing signal to enter into the tapper circuit and reject all unwanted signals (1310 nm, 1490 nm, and 1550 nm) that contaminate the OTDR measurement. The downstream signal will go through the WSC, which in turn connected to optical splitter before it reaches the optical network units (ONUs) at different customer residential locations. On the other hand, the testing signal which is demultiplexed by WSC will be split up again in power ratio 99:1 by using directional coupler (DC) to activate the microprocessor system. The 99% 1625 nm signal will then be configured by using optical splitter, which each output is connected to single line of ONU. CFDS is interfaced with OTDR at CO to accumulate all the troubleshooting results to be displayed on a computer screen for further analysis. Whenever a failure occurs on the primary entity, the traffic (service delivery) is switched from the working (primary) line to the Start Network testing Transfer data into database in PC Display every 8 graphs in a computer screen Check line's status Working condition Show line's detail End Non-working condition Show faulty line & failure location Fig.1. Flow chart for mechanism of CFDS detection
3 INTERNATIONAL JOURNAL OF MICROWAVE AND OPTICAL TECHNOLOGY 130 protection (backup) line to ensure the traffic flow continuously and the failure status will be automatically sent to the field engineers through the mobile phone or Wi-Fi/Internet computer using wireless technology for repairing and maintenance operation. After the restoration/maintenance process, the traffic will be switched back to the normal operation. A. Optical Line Measurement with OTDR In order to gauge the effectiveness and benefits of CFDS, we conducted two experiments through a point-to-point (P2P) network testbed composed by 30 km and 50 km, mainly focusing on fault localization in the network system. Two optical devices: fixed connection (FC) connector and optical attenuator are used as the performance study platform for characterizing optical signal in optical lines in these experiments. The FC connector is used to connect between two s under test, meanwhile the optical attenuator is used to reduce (attenuate) the optical signal level and represent the break point in an optical line. Fig.2. The proposed measurement system configuration for centralized monitoring and localizing fault in FTTH downwardly from CO towards multiple residential customer locations (in downstream direction) PC OTDR DUT RS-232 connection 15 km optical 15 km optical Fig.3. The block diagram of P2P network system configuration consists a single DUT PC OTDR RS-232 connection 15 km optical DUT 1 15 km optical DUT 2 20 km optical Fig.4. The block diagram of P2P network system configuration consists two DUTs
4 INTERNATIONAL JOURNAL OF MICROWAVE AND OPTICAL TECHNOLOGY 131 In the first experiment, there is only consists a single device under test (DUT) which is representing a single event occurs in the testing line as shown in Fig.3. The FC connector used as the DUT in the first test and then replaced by optical attenuator for the following tests. The attenuation at optical attenuator was set as 1 db and increased 1 db for every following test until the optical signal in the testing line is showed failure. The optical network is modified as depicted in Fig.4 to represent two events occur in the testing line. FC connectors used as the DUTs in the first two tests. Then the optical attenuator used to replace the first FC connector as the first DUT (DUT 1). The attenuation at optical attenuator was set as 1 db and increased 2 db for every following test until the optical signal in the tested line is showed failure. Eventually exchanged the position of FC connector with optical attenuator and repeated the same experiment. B. Interfacing between PC with OTDR Each measurement results is saved (recorded) in OTDR as trace (TRC) file and then transferred into PC through RS-232 connection. RS-232 serial cable (null modem cable) is required to establish connection between both units for data archiving. After completing the transferring process, the OTDR traces need to be converted into American Standard Code for Information Interchange (ASCII) form and saved in database. C. Advanced Data Analyzing with CFDS All the measurement results are loaded into the developed program from database. Every eight network testing results will be displayed on a computer screen for further analysis (in Line s Status window). This program is focusing on providing survivability through event identification against optical signal level (input/output power), losses (connection losses, splice losses, optical device/component losses, losses or attenuation), and failures. In this case, CFDS differentiated the mechanism of optical signal in working (good/ideal) and nonworking (breakdown/failure) condition through analyzing the reflective fault event in the network system. CFDS displays a Good condition message at the line's status panel in Line s Detail window if the testing line is in a good/ideal condition without any losses, or a Decreasing y db at z km message to present the magnitude of decreasing together with the location. However in the non-working condition, a failure message Line x FAILURE at z km from CO! will be displayed when CFDS detects any fault occurs in the network system. III. CFDS DEVELOPEMNT CFDS is built by using the Graphical User Interface Development Environment (GUIDE) Layout Editor in MATLAB software. Two main windows (Line s Status and Line s Detail) are reserving for system testing, monitoring, and failure detection. The four basic functionalities of CFDS are: (i) Tracking the optical signal level and losses, (ii) Monitoring and analyzing the line's status, (iii) Displaying the line's detail, and (iv) Visual representation. In combination of the distinctive functions, the network service providers and field engineers can centralize monitoring, testing, analyzing, and troubleshooting the FTTH network system more efficiency to provide the predefined quality of services (QoS) for customer premises/subscribers. IV. TESTING RESULTS AND ANALYSIS A. Execution Display for Single Event When the Open button in Line s Status window is pressed, all the measurement results are loaded from database into MATLAB Current Directory. CFDS accumulated every eight network testing results to be displayed in Line s Status window for centralized monitoring at CO, where the distance (km) represented on the x-axis and optical signal level (db) represented on the y-axis
5 INTERNATIONAL JOURNAL OF MICROWAVE AND OPTICAL TECHNOLOGY 132 as depicted in Fig.5. CFDS analyzed each line's status by tracking every line s optical signal level when pressing the Status button. A failure message Line 8 FAILURE at km from CO! displays to show the faulty line and failure location as depicted in Fig.6. To obtain further details on the performance of specific line in the network system, every measurement results obtained from the network testing are analyzed in the Line s Detail window. CFDS is able to identify and present all the parameters of each optical line such as the line's status, magnitude of decreasing, failure location and further details when pressing the Detail button in Line s Status window or clicked at the individual line in Line s Detail window (see Fig.7 to 10). All the information is mentioned in a specified unit. B. Execution Display for Double Events Every eight graphs that represented the characteristics of optical lines displayed in Line s Status window as depicted in Fig.11. Two failure messages Line 5 FAILURE at km from CO! and Line 8 FAILURE at km from CO! display to show the failure locations in the optical network as shown in Fig.12. The first two tests were featuring with FC connectors as DUTs. The optical power in line 2 is decreasing db at km and db at km (Fig.13). Then the optical attenuator is replacing the FC connector as first DUT. A decreasing of optical power db at distance km and db at km are found in line 3 when the attenuation at optical attenuator set as 1 db (Fig.14). The line 5 is failure while it attenuated at 5 db. A failure message 'Line 5 FAILURE at km from CO!' displays in the Line s Detail window as shown in Fig.15. Fig.16 shows the optical signal breakdown at km when the position of optical attenuator exchanged with FC connector as the second DUT (DUT2). C. Data Analyzing During the experiment period, we were able to observe the behavior of an optical. Theoretically, a signal is transmitted through a medium without any loss in a good condition and we will get a straight line in a power-distance graph. However, the OTDR doesn't show this characteristic in the real case due to it loses power over distance. The optical power is attenuated (reduction of the signal strength or loss of energy) through absorption and scattering mechanisms in. The is attenuated with 0.19 db/km for operating wavelength 1550 nm (0.32 db/km for operating wavelength 1310 nm). For guided media such as optical, the signal strength normally decays exponentially. Normally the logarithmic power ratio measures the changes in the strength of a signal at two different points in unit of decibels (db) [4]. Apart from the propagation loss in a, bending of, connector, splice, coupler, and optical device may also contribute significantly to the losses in an optical communication link. The optical power in line 1 is decreasing db at distance km in the first test due to the alignment of the cores of two s is critical and the minutest misalignment or gap between the s cause significant connectors losses in experiment, as can be seen in Fig.7. Then the FC connector replaced by optical attenuator. When the optical signal transmitted from the laser port to the end of, the optical power in line 2 is decreasing db at distance km as shown in Fig.8. The decreasing power is the losses generated by optical attenuator. When the attenuation at optical attenuator is increasing 1 db for every following test, we can observe that the optical signal level at distance 15 km will be decreasing. The change is clearly shown in Fig.9 when the line was attenuated 10 db. The signal transmission was breakdown at distance km when the attenuation was increasing up to 13 db. It visualized the actual break point of faulty at that distance in the network system in a real condition. A failure message 'Line 8 FAILURE at km from CO!' will display as shown in Fig.10.
6 INTERNATIONAL JOURNAL OF MICROWAVE AND OPTICAL TECHNOLOGY 133 Fig.5. Every eight graphs displayed in Line s Status window for centralized monitoring (Single event) Fig.8. Optical power in line 2 decreased db at distance km Fig.6. A failure message 'Line 8 FAILURE at km from CO!' displays to show the faulty line and failure location in the optical network (Single event) Fig.9. Optical power in line 5 decreased db at distance km Fig.7. Optical power in line 1 decreased db at distance km Fig.10. Line 8 is failure at distance km from the CO when the attenuation at optical attenuator is set as 13 db
7 INTERNATIONAL JOURNAL OF MICROWAVE AND OPTICAL TECHNOLOGY 134 Fig.11. Every eight graphs displayed in Line s Status window for centralized monitoring (Two events) Fig.14. The optical power level in line 3 are decreased db at distance km and db at distance km Fig.12. Two failure messages displayed to show the faulty lines and failure locations in the optical network (Two events) Fig.15. Line 5 is failure at distance km when the attenuation at optical attenuator is set as 5 db Fig.13. The optical power level in line 2 are decreased db at distance km and db at distance km Fig.16. Line 8 is failure at distance km when the attenuation at optical attenuator is set as 5 db
8 INTERNATIONAL JOURNAL OF MICROWAVE AND OPTICAL TECHNOLOGY 135 V. DISCUSSION An OTDR trace is beginning with an initial input pulse. It can be having several common characteristics. Time period for the OTDR trace results from Rayleigh back scattering (RBS) as the laser source travels along the section of optical line are interrupted by an abrupt shifts named as point defects. A point defect is a temporary or permanent local deviation of the OTDR signal either in upward or downward direction. Point defect caused by a connection, splice or failure along an optical line. The output pulse is indicated as end of an optical line from Fresnel reflection occurring at each end. There are four types of events getting from these experiments; they are launch level, section, reflective fault and reflective end. A break produces a reflective fault event in these experiments. Reflective fault are caused by an abrupt discontinuity in the index of refraction (IOR) and it caused a significant portion of the energy initially launched into the to be reflected back towards the source. A loss and a reflective value are normally specified for reflective fault events [5]. CFDS is able to differentiate every line's status and detect the failure occurs in FTTH among a number of subscribers over a maximum distance of km It should be mentioned that CFDS is not limited to scenario with two events (two different conditions), but could be applied to more complicated network configuration. As a remark, we highlight that our strategy may also be modified to be applicable in the long haul optical communication link or -to-the-x (FTTx) schemes. With CFDS no more cost and time misspending due to the troubleshooting mechanism is done downwardly. However, it still has its own limitations. All the network testing results need to be transfer into the PC manually after been measured with the OTDR. Furthermore, the network testing results can only be saved in TRC form in OTDR, but the MATLAB software cannot directly extract the results. Thus the results need to be converted to another form such as ASCII form. Meanwhile, the program can only measure the parameters of optical lines in specific units. VI. CONCLUSION Even through CFDS can help any service providers and field engineers to monitor the status and detect the failure location of optical line in FTTH network, but the program is still under the process of improvement. As discuss in the previous section, it is quite inconvenient to use MATLAB software for the analysis due to its own limitation. In future research activity, we aim to re-develop this program based on underlying software code (such as Visual C++ or C# language). The program will be focused on adding extra new features. When the program is successfully developed, it may help to improve the service reliability and reduce the restoration and maintenance time and cost. ACKNOWLEDGMENT This research work was supported by the Ministry of Science, Technology and Innovation (MOSTI), Government of Malaysia, through National Science Fund (e-science) SF0493. The authors are also grateful to the Photonic Technology Laboratory, Institute of Micro Engineering and Nanoelectronic (IMEN), Universiti Kebangsaan Malaysia (UKM), Malaysia, for providing the facilities to carry out the experiments. REFERENCES [1] C.H. Lee, W.V. Sorin and B.Y. Kim, Fiber to the home using a PON infrastructure, Journal of Lightwave Technology, Vol. 24, No. 12, pp , [2] M.S.A. Rahman, A.A. Ehsan and S. Shaari, Survivability in FTTH PON access network using optical cross add and drop multiplexer switch, Journal of Optical Communication, JOC (German), Vol. 27, No. 5, pp , 2006.
9 INTERNATIONAL JOURNAL OF MICROWAVE AND OPTICAL TECHNOLOGY 136 [3] B. Chomycz, Fiber optic installation: a practical guide, McGraw-Hill, New York, USA, [4] B.A. Forouzan, Data communications and networking, 4 th ed., McGraw-Hill, New York, USA, [5] EXFO, FTB-7000 optical time domain reflectometer series ToolBox 5 instruction manual, 7 th ed., EXFO Electro-Optical Engineering Inc, Canada, 2000.
Detecting faulty fiber with centralized failure detection system (CFDS) in fiber-to-the-home (FTTH) access network
Optica Applicata, Vol. XXXIX, No. 2, 2009 Detecting faulty fiber with centralized failure detection system (CFDS) in fiber-to-the-home (FTTH) access network MOHAMMAD SYUHAIMI AB-RAHMAN *, BOON CHUAN NG,
MTS/T-BERD Platforms Very Long Range (VLR) OTDR Module
COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS MTS/T-BERD Platforms (VLR) OTDR Module Key Features CWDM/DWDM ready with 1310, 1383, 1490, 1550, and 1625 nm wavelengths FTTx ready with 1310/1490/1550 nm wavelengths
Cabling & Test Considerations for 10 Gigabit Ethernet LAN
Introduction Current communication data rates in local networks range from 10/100 megabits per second (Mbps) in Ethernet to 1 gigabit per second (Gbps) in fiber distributed data interface (FDDI) and Gigabit
TROUBLESHOOTING AT THE SPEED OF LIGHT EMBEDDED OTDR FOR OPERATIONAL EXCELLENCE IN PASSIVE OPTICAL NETWORKS
TROUBLESHOOTING AT THE SPEED OF LIGHT EMBEDDED OTDR FOR OPERATIONAL EXCELLENCE IN PASSIVE OPTICAL NETWORKS Application Note Abstract With our increasing dependence on broadband, service disruptions are
Testing a Real Time Monitoring System for Passive Optical Networks using an Array of Fiber Bragg Gratings
Testing a Real Time Monitoring System for Passive Optical Networks using an Array of Fiber Bragg Gratings a Abdosllam M. Abobaker, a Issa Eldbib, a Abdulaziz Hasen Daw, and b P. Ramesh Babu a Department
Cable Network Transparency Fiber Optic Monitoring
Cable Network Transparency Fiber Optic Monitoring Fault recognition, localisation and reporting Fiber Optic Cable Future of Telecommunication The demand for complex fiber optic cable networks and flexible
Removing the Mystery from OTDR Measurements. Keith Foord Product Manager Greenlee Communications
Removing the Mystery from OTDR Measurements Keith Foord Product Manager Greenlee Communications Why an OTDR? Terminology Theory Standards Key specifications Trade-offs Cleaning and Inspection Measurements
WDM Passive Optical Networks: Protection and Restoration
OECC 2009 Workshop: Next-generation Broadband Optical Access Future Challenges Session 1: Broadband Network Architectures, WDM PON Evolution Strategies and Future Ultra-high- bandwidth Services WDM Passive
EPON Technology White Paper
EPON Technology White Paper Content 1.Overview...4 2.Network Architecture...4 3.Principles...5 4.Architecture...6 5.Key Technologies...8 5.1 ONU s Autodiscovery...8 5.2 Synchronization and Ranging...9
BroadbandSoHo. Verizon MDU FTTP Overview. Document Description:
BroadbandSoHo Verizon MDU FTTP Overview Document Description: The enclosed document was created to give a basic overview of Verizon s FTTP PON, and technology terms behind there Fios product in regards
Fiber-to-the-Home/FTTH
Hands-On Design, Installation, Maintenance & Troubleshooting Active and Passive Optical Networks Course Description This Hands-On 2-day course is designed to provide technicians with Hands-On practical
Module 13 : Measurements on Fiber Optic Systems
Module 13 : Measurements on Fiber Optic Systems Lecture : Measurements on Fiber Optic Systems Objectives In this lecture you will learn the following Measurements on Fiber Optic Systems Attenuation (Loss)
ONMSi: Optical Network Monitoring System. Fiber Network Visibility that Scales for Both PON and Point-to-Point Networks
ONMSi: Optical Network Monitoring System Fiber Network Visibility that Scales for Both PON and Point-to-Point Networks y Drastically reduce network downtime y Improve network reliability and SLA management
How To Use Onmsi For Fiber Optic Network Monitoring System
ONMSi: Optical Network Monitoring System Fiber network visibility that scales for both PON and point-to-point networks Drastically reduce network downtime Improve network reliability and SLA management
Genexis FTTH Network Architecture
Genexis FTTH Network Architecture An introduction to the Genexis FTTH Network Architecture This document contains general information about the Genexis FTTH Network Architecture. Contents 1. Introduction...2
ONMSi: Optical Network Monitoring System
ONMSi: Optical Network Monitoring System Fiber network visibility that scales for both PON and point-to-point networks Drastically reduce network downtime Improve network reliability and SLA management
Passive Optical Networks Beneficial to Cloud Computing
Passive Optical Networks Beneficial to Cloud Computing Ankit Chandle Shoolini University Avtar Singh Shoolini University Naresh Kumar Deptt. Of E.C.E Shoolini University, Anju Bala Shoolini University,
WDM-PON: A VIABLE ALTERNATIVE FOR NEXT GENERATION FTTP
WDM-PON: A VIABLE ALTERNATIVE FOR NEXT GENERATION FTTP AN ENABLENCE ARTICLE WRITTEN BY DR. MATT PEARSON, VP TECHNOLOGY PUBLISHED IN FTTH PRISIM MAGAZINE March, 2010 www.enablence.com Most of the Fiber-to-the-Home
Comprehensive geospatial network management based on MapInfo. Supporting both physical and logical network resource management
Comprehensive geospatial network management based on MapInfo Supporting both physical and logical network resource management ConnectMaster is an open, integratable, scalable software solution for the
Extending Ethernet over 2-wire Copper Networks
Extending Ethernet over 2-wire Copper Networks Executive Summary To improve the efficiency of industrial automation systems, many operators are considering the possibility of IP upgrades to provide centralised
Gigabit Passive Optical Networks
White Paper Gigabit Passive Optical Networks Passive Optical LAN Solutions (POLS) Theory, Design, and Installation Considerations Sean McCloud, RCDD Senior Applications Engineer, Leviton Network Solutions
Tracing Live or Dark FTTx PONs through Splitter using OFL280
Introduction AFL s PON-optimized OFL280-103 FlexTester is ideally suited for both out-of-service installation testing, as well as in-service fault location on FTTx PON networks. The OFL280-103 s unique
Broadband 101: Installation and Testing
Broadband 101: Installation and Testing Fanny Mlinarsky Introduction Today the Internet is an information superhighway with bottlenecks at every exit. These congested exits call for the deployment of broadband
INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT
INTERNATIONAL TELECOMMUNICATION UNION ITU-T L.52 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (05/2003) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT
DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES)
Features: DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES) PATENT NUMBERS: CANADA 2,494,133, USA 7095931, 7295731 AND CHINA 1672073 Telcordia GR-468 qualified Available in versions for any wavelength
Optical Network Management System. Remote Testing, Network Monitoring, and Service Provisioning Solution for High-Quality Network Performance
Optical Network Management System Remote Testing, Network Monitoring, and Service Provisioning Solution for High-Quality Network Performance JDSU Enabling Broadband and Optical Innovation Improving the
10-3. SYSTEM TESTING AND DOCUMENTATION
10-3. SYSTEM TESTING AND DOCUMENTATION System testing and documentation must cover pre-installation testing, sub-system testing, fiber optic cable testing, video link testing, data link testing, acceptance
Fiber to the Home. Definition. Overview. Topics
Fiber to the Home Definition Fiber to the home (FTTH) is the ideal fiber-optics architecture. In this architecture, fiber deployment is carried all the way to the customer s home (premises). Overview Today
Optical Fiber Data Center Field Testing. ANSI/BICSI 002-2011 Data Center Design and Implementation Best Practices
Optical Fiber Data Center Field Testing ANSI/BICSI 002-2011 Data Center Design and Implementation Best Practices Abstract Data Centers are a growing segment of the enterprise market. Regardless of whether
IPv6 Broadband Access Network Systems
IPv6 Broadband Access Network Systems IPv6 Broadband Access Network Systems 60 Junji Yamada Koji Wakayama Eisuke Sato OVERVIEW: To meet the demand for broadband access and enable a smooth transition from
FIBER OPTIC SYSTEM TEST PROCEDURES
FIBER OPTIC SYSTEM TEST PROCEDURES Data Systems Performance Engineering LLC performs three tests in order to determine fiber optic cable adequacy. The order in which the tests are to be performed is not
Technical Bulletin. Guidelines For Testing And Troubleshooting Fiber Optic Installations
The Fiber Optic Association, Inc. 1119 S. Mission Road #355, Fallbrook, CA 92028 1-760-451-3655 Fax 1-781-207-2421 Email: [email protected] http://www.thefoa.org Technical Bulletin Guidelines For Testing
OTDR-based Monitoring in Passive Optical Networks
Università degli Studi di Padova DIPARTIMENTO DI INGEGNERIA DELL INFORMAZIONE Corso di Laurea Magistrale in Ingegneria delle Telecomunicazioni OTDR-based Monitoring in Passive Optical Networks Relatore:
Code-division multiplexing for in-service out-of-band monitoring of live FTTH-PONs
Vol. 6, No. 7 / July 2007 / JOURNAL OF OPTICAL NETWORKING 819 Code-division multiplexing for in-service out-of-band monitoring of live FTTH-PONs Habib Fathallah* and Leslie A. Rusch* Centre d Optique Photonique
Explanation of Reflection Features in Optical Fiber as Sometimes Observed in OTDR Measurement Traces
Explanation of Reflection Features in Optical Fiber as Sometimes Observed in OTDR Measurement Traces WP1281 Issued: November 2015 Supersedes: 2012 Author: Dr. Russell Ellis ISO 9001 Registered Background
FTTH ARCHITECTURE WHITE PAPER SERIES
Not all FTTH networks are built the same. Since construction and outside plant account for the majority of total network costs, getting the architecture right has a major impact on the business case. The
Measuring of optical output and attenuation
Measuring of optical output and attenuation THEORY Measuring of optical output is the fundamental part of measuring in optoelectronics. The importance of an optical power meter can be compared to an ammeter
T1 Networking Made Easy
T1 Networking Made Easy 1 THE T1 CARRIER 3 WHAT DOES A T1 LOOK LIKE? 3 T1 BANDWIDTH 3 T1 PHYSICAL CHARACTERISTICS 4 T1 FRAMING 5 LINE CODE 6 T1 NETWORKING 6 TELCOS 6 PSTN ACCESS WITH A T1 8 SUMMARY OF
Bandwidth analysis of multimode fiber passive optical networks (PONs)
Optica Applicata, Vol. XXXIX, No. 2, 2009 Bandwidth analysis of multimode fiber passive optical networks (PONs) GRZEGORZ STEPNIAK *, LUKASZ MAKSYMIUK, JERZY SIUZDAK Institute of Telecommunications, Warsaw
Live Fiber Monitoring in CWDM Networks
Live Fiber Monitoring in CWDM Networks Olivier Plomteux, Senior Product Line Manager, Optical Business Unit To cope with the signifi cant increase for storage and on-demand delivery of digital content,
Enhanced Security in Passive optical Networks using WDM PON
Enhanced Security in Passive optical Networks using WDM PON Rajasekaran. V. L Asst.Professor, Faculty of ECE, St.Joseph College of Engineering, Tamil Nadu, India. Esther Sheeba Jasmine. H PG Scholar, Applied
Cable 101. A Broadband Telecommunications Primer for Non-technical Personnel
Cable 101 KnowledgeLink, Inc. A Broadband Telecommunications Primer for Non-technical Personnel Presented by: Justin J. Junkus President, KnowledgeLink, Inc. November 20, 2013 Agenda Broadband Cable Systems
FTTH Explained: Delivering efficient customer bandwidth and enhanced services Michael Kunigonis Product Line Manager Access Corning Cable Systems
FTTH Explained: Delivering efficient customer bandwidth and enhanced services Michael Kunigonis Product Line Manager Access Corning Cable Systems Overview: Telecommunication carriers worldwide have come
Next Generation Optical Fibre: Making Your Broadband Network Go Further
Next Generation Optical Fibre: Making Your Broadband Network Go Further WP2401 Issued: April 2011 Authors: Dr. Merrion Edwards and Vanesa Diaz Introduction As a recent blockbuster video on YouTube called
Field Measurements of Deployed Fiber
Field Measurements of Deployed Fiber Robert J. Feuerstein Level 3 Communications, 1025 Eldorado Boulevard, Broomfield, Colorado 80021 [email protected] Abstract: New generations of ultra-long
Planning for Universal Broadband Solving for x
Planning for Universal Broadband Solving for x Kermit L. Ross President, NDDI Broadband Is the New Universal For most of the last century, telephone companies built networks designed for voice services,
An advanced Dark Fiber Monitoring System for Next Generation Optical Access Networks
An advanced Dark Fiber Monitoring System for Next Generation Optical Access Networks Min Cen, Jiajia Chen, Véronique Moeyaert, Patrice Mégret and Marc Wuilpart 18th Annual Workshop of the IEEE Photonics
A Simple Fiber Bragg Grating-Based Sensor Network Architecture with Self-Protecting and Monitoring Functions
Sensors 2011, 11, 1375-1382; doi:10.3390/s110201375 OPEN ACCESS sensors ISSN 1424-8220 www.mdpi.com/journal/sensors Article A Simple Fiber Bragg Grating-Based Sensor Network Architecture with Self-Protecting
The Economics of Broadband Access Platform Evolution
The Economics of Broadband Access Platform Evolution The EU's ACTS (Advanced Communications Technologies and Services) research programme has tested a number of approaches to delivering broadband services
Attaching the PA-A1-ATM Interface Cables
CHAPTER 4 Attaching the PA-A1-ATM Interface Cables To continue your PA-A1-ATM port adapter installation, you must attach the port adapter cables. The instructions that follow apply to all supported platforms.
Carrier Ethernet: New Game Plan for Media Converters
Introduction IEEE Std. 802.3ah, also referred to as Ethernet in the First Mile (EFM) standard, has a well established name within the industry today. It lays out ground rules for implementing Ethernet
FiberHome s XGPON Solution
FiberHome s X Solution 1 X Application Scenarios The application of digital FTTH family Due to the service development, bandwidth requirements are raised. will be replaced by X technology which provides
palmotdr Series Handheld OTDR
palmotdr Series Handheld OTDR Most Compact High-Performance OTDR Comprehensive fiber applications, ideal for LAN/WAN/FTTx certification & trouble-shooting: SM: 1310/1490/1550, 1625/1650nm (with filter),
Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications
Data Sheet Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications The industry-standard Cisco Small Form-Factor Pluggable (SFP) Gigabit Interface Converter is a hot-swappable input/output
Cisco SFP Optics for Gigabit Ethernet Applications
Cisco SFP Optics for Gigabit Ethernet Applications The industry-standard Cisco Small Form-Factor Pluggable (SFP) Gigabit Interface Converter is a hot-swappable input/output device that plugs into a Gigabit
The Conversion Technology Experts. Fiber Optics Basics
The Conversion Technology Experts Fiber Optics Basics Introduction Fiber optic technology is simply the use of light to transmit data. The general use of fiber optics did not begin until the 1970s. Robert
DISASTER RECOVERY AND NETWORK REDUNDANCY WHITE PAPER
DISASTER RECOVERY AND NETWORK REDUNDANCY WHITE PAPER Disasters or accidents would cause great harm on network infrastructure. It is unavoidable and the operation of network would be hampered for a long
White Paper: 10GbE Fiber A Practical Understanding and Functional Approach
White Paper: 10GbE Fiber A Practical Understanding and Functional Approach Dennis Manes, RCDD Senior Applications Engineer Leviton Network Solutions E/8 #2509 Table of Contents Introduction 3 Types of
A Review of Security System for Smart Home Applications
Journal of Computer Science 8 (7): 1165-1170, 2012 ISSN 1549-3636 2012 Science Publications A Review of Security System for Smart Home Applications Mohammad Syuhaimi Ab-Rahman and Mohd Ariff Razaly Department
SOLUTIONS FOR AN EVOLVING WORLD. T1/E1 and C37.94. Fiber Service Units
SOLUTIONS FOR AN EVOLVING WORLD T1/E1 and C37.94 Fiber Service Units T1/E1 & C37.94 1 April 2013 Your world is changing and so are we. At RFL, we know your needs change much faster than your infrastructure.
Large-Capacity Optical Transmission Technologies Supporting the Optical Submarine Cable System
Large-Capacity Optical Transmission Technologies Supporting the Optical Submarine Cable System INOUE Takanori Abstract As one of the foundations of the global network, the submarine cable system is required
Gigabit-capable Passive Optical Networks (GPON): General characteristics
Gigabit-capable Passive Optical Networks (GPON): General characteristics SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS Digital sections and digital line system Optical line systems
Maximizing the Impact of Optical Technology OFC/NFOEC 2007
Maximizing the Impact of Optical Technology OFC/NFOEC 2007 Mark Wegleitner Senior VP Technology, CTO Verizon March 27, 2007 Traffic Growth 2000 Video downloads 1500 1000 700 600 500 400 300 200 100 0 0
Simulation and Best Design of an Optical Single Channel in Optical Communication Network
International Arab Journal of e-technology, Vol., No., June 11 91 Simulation and Best Design of an Optical Single Channel in Optical Communication Network Salah Alabady Computer Engineering Department,
(Refer Slide Time: 2:10)
Data Communications Prof. A. Pal Department of Computer Science & Engineering Indian Institute of Technology, Kharagpur Lecture-12 Multiplexer Applications-1 Hello and welcome to today s lecture on multiplexer
Line Monitoring and Control in Subsea Networks
Line Monitoring and Control in Subsea Networks This paper discusses how submerged equipment is monitored and contrasts different methods of doing this. It also considers what features are required by the
Multi-Dwelling Unit Fiber Deployment
Multi-Dwelling Unit Deployment Billions of dollars are spent annually delivering high speed fiber networks to Multi-Dwelling Units (MDUs) apartments, condos, and student-housing across North America. Service
Construction of High-speed and High-reliability Optical Networks for Social Infrastructure
Hitachi Review Vol. 59 (Feb. 2010) 1 Construction of High-speed and High-reliability Optical Networks for Social Infrastructure Ryosuke Nishino Hideaki Tsushima, Dr. Eng. Eisuke Sato Shinsuke Tanaka OVERVIEW:
Introduction to Add-Drop Multiplexers
3 Introduction to Add-Drop Multiplexers In this chapter different channel routing technologies are reviewed, highlighting the advantages and drawbacks of the different devices and configurations. The parameters
Ethernet Passive Optical Networks EPON
Ethernet Passive Optical Networks EPON IEEE 802.3 Ethernet in the First Mile Study Group January 8-9, 2001, Irvine, CA Gerry Pesavento Alloptic, Inc. Tel 925-245-7647 Email [email protected]
PON Technology A Shift in Building Network Infrastructure. Bob Matthews Technical Manager CommScope Canada
PON Technology A Shift in Building Network Infrastructure Bob Matthews Technical Manager CommScope Canada The Evolution to PON In 1980s -1990s, we had: Dial up modems The best data rate we could get from
E-Option Multi-taps Conditioning at the Tap
E-Option Multi-taps Conditioning at the Tap (actual size) Introduction Traditional Cable Television Systems had long been associated with one-way downstream signal transmissions that provide video services
RF Network Analyzer Basics
RF Network Analyzer Basics A tutorial, information and overview about the basics of the RF Network Analyzer. What is a Network Analyzer and how to use them, to include the Scalar Network Analyzer (SNA),
Advantages of Fiber Optic Splitters in Key Applications Increase the Efficient Use of Optical Infrastructure with These Passive Components
Increase the Efficient Use of Optical Infrastructure with These Passive Components Overview Fiber optic splitters play an increasingly significant role in many of today s optical network topologies. From
POS Integration. Prepared by: Binh Nguyen
POS Integration Prepared by: Binh Nguyen Point of Sale (POS) Compatibility To know whether it is possible to integrate your POS system with our DVR, please check whether the type of printer the POS system
CONDIS. IT Service Management and CMDB
CONDIS IT Service and CMDB 2/17 Table of contents 1. Executive Summary... 3 2. ITIL Overview... 4 2.1 How CONDIS supports ITIL processes... 5 2.1.1 Incident... 5 2.1.2 Problem... 5 2.1.3 Configuration...
Optical Submarine Cable Network Monitoring Equipment
Optical Submarine Cable Network Monitoring Equipment NOMURA Kenichi, TAKEDA Takaaki Abstract The introduction of large-capacity wavelength-division multiplexing and OADM (Optical Add/Drop Multiplexing)
TereScope Management Options
Introduction TereScope Management Options MRV Communications, Inc. offers a variety of management options for the TereScope FSO product family. Whether you are a Network Service Provider, Cellular Network
FALCO. Broadband Groomer. F-330 Series. Applications. Access system for:
Broadband Groomer F-330 Series Falco is the industry first Access Unit designed to offer access to SDH/SONET/PDH backbones by different. extends the usefulness of WAN/LAN to and GbE backbones. Falco combines
Accurately Testing fibre Optic Cables
Accurately Testing fibre Optic Cables Note: You need to know what we mean when we say accurate that the measurement made gives a value close to the real value. Standards people prefer we refer to the uncertainty
CADDSTAR V7.0 FEATURES AND FUNCTIONALITY
CADDSTAR V7.0 FEATURES AND FUNCTIONALITY CADDStar is a powerful GIS-based facilities management and network documentation software. By combining the drawing / mapping features of AutoCAD Map with a relational
Perle 10/100 Ethernet Media Converters
Perle 10/100 Ethernet Media Converters Installation Guide S-110-XXXXXX S-110-XXXXXX-XT P/N 5500302-16 (Rev B) Overview This document contains instructions necessary for the installation and operation of
Fiber to the Home: Enabling Innovation & Growth. Stuart Elby, PhD Vice President -- Technology
Fiber to the Home: Enabling Innovation & Growth Stuart Elby, PhD Vice President -- Technology Communications Trends Access Bandwidth Consumption 4G 3G 2/2.5G 2 Infonetics, Alcatel-Lucent Applications and
Optimux-45, Optimux-45L Multiplexers for 21E1/28T1 over Fiber or T3
Data Sheet Optimux-45, Optimux-45L Up to 28 T1 or 21 E1 channels multiplexed into a single 45 Mbps data stream Any Traffic over Fiber Combination of T1 and E1 channels Transmission over coax or fiber optic
Joint ITU-T/IEEE Workshop on Next Generation Optical Access Systems. Verizon FiOS FTTP Deployment and NG PON Perspectives
Joint ITU-T/IEEE Workshop on Next Generation Optical Access Systems Verizon FiOS FTTP Deployment and NG PON Perspectives Martin Carroll DMTS Network and Technology Verizon FTTP: Future Proofing Upstream
CISCO WDM SERIES OF CWDM PASSIVE DEVICES
DATA SHEET CISCO WDM SERIES OF CWDM PASSIVE DEVICES Cisco Systems introduces its second generation of coarse wavelength-division multiplexing (CWDM) passive devices boasting increased functions and improved
Prospects and Problems GPON Technology over Ethernet Technology
Prospects and Problems GPON Technology over Ethernet Technology Md. Hayder Ali [email protected] SANOG 23 Conference Thimpu, Bhutam Bangladesh : Name: People's Republic of Bangladesh Population: 164.4
Current access technologies overview
White Paper Current access technologies overview In this paper, we explore six basic technology choices for deploying broadband services to the end customer xdsl, DOCSIS, G.fast, satellite, wireless and
Connect & Go with WDM PON Ea 1100 WDM PON
Connect & Go with WDM PON Ea 1100 WDM PON ericsson deep Fiber access Connectivity Begins in the Access Speed, connectivity, Efficiency In much the same way the worldwide web changed the traditional voice
Fiber Optic. Passive Components Edition 2009
Fiber Optic Passive Components Edition 2009 Reliably connected to your network Your partner for system solutions The HUBER+SUHNER Group is a leading global supplier of components and systems for electrical
OPTICAL NETWORKS. Optical Access Networks. A. Gençata İTÜ, Dept. Computer Engineering 2005
OPTICAL NETWORKS Optical Access Networks A. Gençata İTÜ, Dept. Computer Engineering 2005 Outline Broadband access network architectures employing Passive (PONs). The potential of PONs to deliver high bandwidths
Distributed Intrusion Monitoring System With Fiber Link Backup and On-Line Fault Diagnosis Functions
PHOTONIC SENSORS / Vol. 4, No. 4, 14: 354 358 Distributed Intrusion Monitoring System With Fiber Link Backup and On-Line Fault Diagnosis Functions Jiwei XU, Huijuan WU *, and Shunkun XIAO Key Laboratory
Deploying VSaaS and Hosted Solutions Using CompleteView
SALIENT SYSTEMS WHITE PAPER Deploying VSaaS and Hosted Solutions Using CompleteView Understanding the benefits of CompleteView for hosted solutions and successful deployment architecture Salient Systems
Three Key Design Considerations of IP Video Surveillance Systems
Three Key Design Considerations of IP Video Surveillance Systems 2012 Moxa Inc. All rights reserved. Three Key Design Considerations of IP Video Surveillance Systems Copyright Notice 2012 Moxa Inc. All
Video Architectures Eyes on the Future: The Benefits of Wireless Technology for Fixed Video Surveillance
S O L U T I O N PA P E R Video Architectures Eyes on the Future: The Benefits of Wireless Technology for Fixed Video Surveillance Table of Contents Fixed Video Surveillance: The Big Three... 3 Wireless
How To Define Hfc Technology
Cable network topologies and implications for evolutionary approaches 33 rd International conference and Exhibition PIKE 2008, Zakopane, 14 October 2008 Bart Brusse, ReDeSign Project Manager Pressure on
Best Practices for Ensuring Fiber Optic System Performance. David Zambrano
Best Practices for Ensuring Fiber Optic System Performance David Zambrano Inspect Before You Connect Optical Connectors in our Networks Contamination and Signal Performance Sources of Contamination Process
Convergence of Advanced Information and Control Technology in Advanced Metering Infrastructure (AMI) Solution
Convergence of Advanced Information and Control Technology in Advanced Metering Infrastructure (AMI) Solution 138 Convergence of Advanced Information and Control Technology in Advanced Metering Infrastructure