MAINSPRING DATA EXPRESS
|
|
|
- Melinda Gaines
- 9 years ago
- Views:
Transcription
1 MAINSPRING DATA EPRESS MDTCSG2 version 3.0 Mainspring Data Express Connectivity Guide Caution: Federal Law (USA) restricts this device to sale by or on the order of a physician (or a properly licensed practitioner)
2 Trademarks The following are trademarks or registered trademarks of Medtronic in the United States and possibly in other countries: Medtronic, Medtronic CareLink, Paceart Optima, Paceart
3 Connectivity Guide Contents i Contents Mainspring Data Express...3 Explanation of symbols...3 Indications...4 Precautions...4 Contraindications...5 Mainspring Data Express Authorized Users...5 Technical Support...5 Mainspring Data Express Software Prerequisites...6 First-Time Installation Prerequisites...6 Installing and Configuring MS Message Queuing for Windows P...6 Installing and Configuring MS Message Queuing for Windows Vista and Windows Installing and Configuring MS Message Queuing for Windows Server Installing and Configuring MS Message Queuing for Windows Server Adding or editing a Paceart External System Accounts user...2 Adding or editing a Paceart External System role...2 Adding an External System Account in CareLink...3 Upgrade Installation Prerequisites...4 Stopping the Connected Systems Gateway Service...4 Installing Mainspring Data Express...5 Automatically Starting the Connected Systems Gateway After Restart...6 Restarting the Connected Systems Gateway Service Automatically...7 Log File Configuration...7 Paceart Integration...8 General Paceart Settings...8 Configuring Paceart Settings...8 Paceart Integration Configuration Values...9 One-Stop Scheduling...9 One-Stop Scheduling Prerequisites...20 Configuring One-Stop Scheduling...20 Troubleshooting One-Stop Scheduling...22 HL7 Integration...22 Configuring Paceart HL7 Integration...23 Paceart Optima HL7 Integration...27 Troubleshooting Paceart HL7 Integration...22 Local Data Interface...23 Local Data Interface Extended Configurations...23 Local Data Interface certificate installation...23 Enabling a data import source...24 Remote Data Interface...24 Configuring Remote Data Interface...24 Enabling remote data acquisition in Paceart...26
4 ii Connectivity Guide Contents CareLink Integration...27 Mainspring Report Export...27 Mainspring Report Export Prerequisites on CareLink...27 Configuring Mainspring Report Export...27 Enabling and Verifying Mainspring Report Export Troubleshooting Mainspring Report Export...22 Paceart ML Schema valid values Paceart ML export ML Domain Mapping...225
5 Connectivity Guide Mainspring Data Express 3 Mainspring Data Express Mainspring like the inner workings of a clock it is the power source that facilitates the movement of cardiac data within your clinic, and between various departments within your organization. Mainspring Data Express is a comprehensive solution for your cardiac patients, bringing together device and patient data from the Paceart System, the Medtronic CareLink Network, the CareLink Programmer, the Boston Scientific LATITUDE Patient Management system, the St. Jude Medical Merlin.net Patient Care Network, your EHR System, and local network. In order to simplify the process of connecting and sharing demographic, scheduling, and device data between Medtronic applications and electronic health record systems (EHRs), Medtronic has developed Mainspring Data Express. This software application serves as the primary tool to move and share data for device patients. Mainspring Data Express helps to streamline the implementation and on-going maintenance of data movement between applications. This manual explains the process for installing the Mainspring Data Express software and configuring the features. Explanation of symbols Symbol Symbol definition Consult instructions for use For US audiences only Authorized Representative in the European Community Manufacturer Lot number Re-order number Date of Manufacture Conformité Européenne (European Conformity). This symbol means that the device fully complies with European Directive MDD 93/42/EEC. The Paceart Optima System, including optional system components, is CE marked. Optional system components include CareLink Scheduling Integration, HL7 Integration, Local Data Interface, and Remote Data Interface. The CareLink Report Export component is not a medical device and therefore does not need to be CE marked according to MDD 93/42/EEC.
6 4 Connectivity Guide Mainspring Data Express Symbol Symbol definition Do not dispose of this product in the unsorted municipal waste stream. Dispose of this product according to local regulations. See for instructions on proper disposal of this product. Temperature Limitation Humidity Limitation Software Indications Mainspring Data Express is an optional component of the Medtronic CareLink Network and Paceart Optima System. Mainspring Data Express can be used to perform the following tasks: Save CareLink reports to a network location. Exchange scheduling data between CareLink and Paceart. Bring in demographic and scheduling information from electronic medical record systems or practice management systems via HL7. Export device data to electronic medical record systems via HL7. Import device data via SessionSync Import device data to Paceart via HL7 (for properly formatted IDCO messages) Import device data to Paceart from Merlin.Net integration Import device data to Paceart from Latitude integration For more information on the Medtronic CareLink Network, refer to the CareLink Network online Help. For more information on the Paceart Optima System, refer to the Paceart Optima System Software User Manual or the Paceart Optima System online Help. Precautions Mainspring Data Express USBs must be stored within the following conditions: Storage Environment Temperature Relative Humidity -20 C (-4 F) to +45 C (3 F) 5% to 95% Mainspring Data Express USBs must be operating in an environment within the following conditions: Operating Environment Temperature 0 C (32 F) to +35 C (95 F)
7 Connectivity Guide Mainspring Data Express 5 Operating Environment Relative Humidity 5% to 95% Call customer service or your biomedical department for service and repairs. Contraindications No known contraindications. Mainspring Data Express Authorized Users Medtronic representatives provide the Mainspring Data Express orientation and training materials at the time of the installation. Users should be familiar with the Mainspring Data Express documents before using Mainspring Data Express. Technical Support In the US and Canada, call and select option 3. For all other countries contact your local Medtronic representative.
8 6 Connectivity Guide Mainspring Data Express Software Prerequisites Mainspring Data Express Software Prerequisites Before you install and configure the Mainspring Data Express software you must complete the following prerequisites: Install and Configure MS Message Queuing. Create a Mainspring Data Express user on the Paceart Database if you are using SQL Server authentication (not needed if using Windows Authentication). First-Time Installation Prerequisites If you are installing the Mainspring Data Express software for the first time, and not an upgrade, you must complete the following prerequisites before you can install the Mainspring Data Express software. Create an External Systems Account on the CareLink Network. Install and configure MS Message Queuing. Installing and Configuring MS Message Queuing for Windows P. Click Start > Control Panel. 2. Double-click Add or Remove Programs. 3. Click Add/Remove Windows Components. The Windows Components Wizard dialog opens. 4. Select Message Queuing from the Windows Components Wizard dialog.
9 Connectivity Guide Mainspring Data Express Software Prerequisites 7 5. Click Details. 6. Select Common from the list of Subcomponents of Message Queuing. 7. Click OK on the Message Queuing dialog. 8. Click Next on the Windows Components Wizard dialog. 9. When the installation completes click Finish. Installing and Configuring MS Message Queuing for Windows Vista and Windows 7. Click Start > Control Panel. 2. Click Programs and Features. 3. Under the Windows and Features section, click Turn Windows features on or off.
10 8 Connectivity Guide Mainspring Data Express Software Prerequisites 4. Under the Microsoft Message Queue (MSMQ) Server option, check the Microsoft Message Queue (MSMQ) Server Core option. This enables all of the MSMQ Server Core subfeatures. 5. Click OK. Installing and Configuring MS Message Queuing for Windows Server Open the Control Panel. 2. Double-click Add or Remove Programs. 3. Click Add/Remove Windows Components. 4. Select Application Server from the Windows Components Wizard dialog.
11 Connectivity Guide Mainspring Data Express Software Prerequisites 9 5. Click Details. 6. Select Message Queuing. 7. Click Details. 8. Select Core Functionality from the list of Subcomponents of Message Queuing.
12 0 Connectivity Guide Mainspring Data Express Software Prerequisites 9. Click OK on the Message Queuing dialog. 0. Click Next on the Windows Components Wizard dialog.. When the installation completes click Finish. Installing and Configuring MS Message Queuing for Windows Server Click Start > Control Panel. 2. Double-click Programs and Features. 3. Click Turn Windows features on or off. The Server Manager window is displayed. 4. Select Add Features in the Features and Summary section. The Add Feature Wizard dialog is displayed.
13 Connectivity Guide Mainspring Data Express Software Prerequisites 5. Under the Message Queuing > Message Queuing Services option, select the Message Queuing Server option. 6. Click Next on the Add Feature Wizard dialog box to select features. 7. Click Install on the Add Feature Wizard dialog box to confirm your installation selections. 8. When the installation is complete, click Close.
14 2 Connectivity Guide Mainspring Data Express Software Prerequisites Adding or editing a Paceart External System Accounts user You can add or edit an External System Account. Creating separate External System Account users allows you to connect to external systems, such as the Medtronic CareLink Network, with different permissions than a typical Paceart user would have.. Click Administration > Security > External System Accounts. 2. Determine which action to take. To add an external user account, click Add. To edit an existing external user account, select the user in the External System Accounts section and click Edit. 3. Enter user and account information for the user as necessary. If you are editing an existing user, the user name and password information are not editable. The user name appears on printed reports and logs. The set password function can be used to reset the password for an existing user. 4. Click Save. The user is saved and displayed in alphabetical order in the External System Accounts section. Adding or editing a Paceart External System role You can add or edit an External System role. An External System role is a set of permissions that can be assigned to a user who will be connecting to an External System, such as the Medtronic CareLink Network.. Click Administration > Security > External System Roles. 2. Determine which action to take. To add an external role, click Add. To edit an existing external role, select the role in the External System Roles section and click Edit.
15 Connectivity Guide Mainspring Data Express Software Prerequisites 3 3. Enter the role information and identify the permissions for the role as necessary. 4. Click Save. The role is saved and displayed in alphabetical order in the External System Roles section. Adding an External System Account in CareLink You can add an external system account. External system accounts are used to enable CareLink integration with external systems for scheduling integration, transmission data export, and report export. You must have complete administrative privilege to add an external system account.. From the External Systems Account page, click Add Account. The Create External System Account page will display. 2. Enter an account name. The account name must be 7 to 2 characters long. At least one character must be a number (0-9). The characters / \ [ ],. + = * : : are not allowed in account names. The account name must be unique. 3. Enter and authorization code. The authorization code must be 7 to 2 characters long. At least one character must be a number (0-9). The authorization code must be different than the account name. 4. Select Report Export to enable report exporting from CareLink. 5. If there are multiple clinics in your network, select the clinic or clinics to which the external system account should be applied. You can only select clinics to which you have been given access. Click Select All to select all clinics in the list. 6. Click Save. When the account is created successfully, the confirmation message "You have successfully added the External System Account" will display. The account information will display in read-only form. If the account name is already in use, the error message "The account name that you entered is already in use" will display. Enter a different account name, and click Save.
16 4 Connectivity Guide Mainspring Data Express Software Prerequisites Upgrade Installation Prerequisites If you are upgrading to a new version of Mainspring Data Express software you must first stop the existing Connected Systems Gateway service. You do not need to uninstall your existing Connected Systems Gateway software. The new version of the software will import any existing configurations. For example, if you have an existing Paceart-CareLink scheduling integration configuration, the settings will be saved and used in the new version of the Mainspring Data Express software. Stopping the Connected Systems Gateway Service Before you install a new version of the Medtronic Mainspring Data Express software you must stop the existing Connected Systems Gateway service.. To stop the Connected Systems Gateway service go to Start > Control Panel > Administrative Tools > Services. 2. Right-click on the Connected Systems Gateway service and select Stop.
17 Connectivity Guide Installing Mainspring Data Express 5 Installing Mainspring Data Express Complete the items listed in the prerequisites section before you install and configure the Mainspring Data Express software.. To start the installation, insert the Mainspring Data Express installation USB into the computer. The setup program will automatically start. If you are installing on a Windows 2003 Server, you must manually start the installation program by clicking the CSGInstall.exe on the installation USB. If the setup program does not automatically start, you can manually start the installation program by clicking CSGInstall.exe on the installation USB. 2. Click Next. 3. Enter a destination folder. Click Change to change from the default location of C:\Program Files\Medtronic\Connected Systems Gateway\. If you have a previous version of the Connected Systems Gateway installed use the same filepath as the previous version. 4. Click Next. 5. Click Install. A progress bar shows the installing progress. 6. Select Launch Medtronic Mainspring Data Express and then click Finish to exit the installation wizard and open the Medtronic Mainspring Data Express window.
18 6 Connectivity Guide Installing Mainspring Data Express Automatically Starting the Connected Systems Gateway After Restart. After you verify that your implementation was successful you can set this service to automatically connect. Go to Start > Control Panel > Administrative Tools > Services. 2. Right-click on the Connected Systems Gateway service and select Properties. 3. Select Automatic in the Startup type field. If you restart your computer this service will automatically restart. 4. Click OK.
19 Connectivity Guide Installing Mainspring Data Express 7 Restarting the Connected Systems Gateway Service Automatically After you verify that your implementation was successful you can set this service to automatically restart.. Go to Start > Control Panel > Administrative Tools > Services. 2. Right-click the Connected Systems Gateway service and select Properties. 3. Select Automatic in the Startup type field. If you restart your computer this service will automatically restart. 4. Click OK. Log File Configuration The default location for log files is C:\Program Files\Medtronic\Connected Systems Gateway\Logs\. The default log file retention count is 0. You can save up to 99 log files.
20 8 Connectivity Guide Paceart Integration Paceart Integration The Paceart Integration section of Mainspring Data Express has the following features: One-Stop Scheduling: Allows you to exchange scheduling data between the CareLink Network and Paceart. HL7 Integration: Allows you to import demographic information, scheduling information, and interrogated device data using ORU^R0 messages that conform to the IHE IDCO profile, from electronic medical record systems or practice management systems. Also allows you to export device data to electronic medical record systems via HL7. Local Data Interface: Allows you to configure the service that receives patient session data transmitted from local sources, such as a device programmer or Latitude. Remote Data Interface: Allows you to configure the service that imports patient session data from remote sources, such as the CareLink Network. General Paceart Settings General Paceart External System Account This section gives you a simple way to configure a single account to use with all your all the integration features. To enable this account for all Paceart features select the Use General Paceart External System Account Settings on the feature-specific tab. To use different External System Accounts for each feature uncheck the Use General Paceart External System Account Settings on the feature-specific tab. Paceart Web Services When installing the Paceart server a certificate is bound to either the host name or IP address of the server. If the certificate is bound to the IP address of the server, then the IP address must be used in each of these settings. If the certificate is bound to the Hostname of the server, than the Hostname must be used for these settings. Configuring Paceart Settings General Paceart Settings can be modified by editing the paths. For each of the Paceart Web Services, the localhost need to be replaced with the hostname and port number.. To start Mainspring Data Express, go to Start > Programs > Medtronic Mainspring Data Express > Medtronic Mainspring Data Express. 2. In the Medtronic Mainspring Data Express window, select at least one of the following Paceart Integration features and click Configurations: One-Stop Scheduling HL7 Integration Local Data Interface Remote Data Interface The Paceart Integration configuration window is displayed. 3. In the General Paceart Settings section, replace "localhost" with the hostname or the IP address of the server and the port number in each of the Paceart Web Services paths. When you installed Paceart a server
21 Connectivity Guide Paceart Integration 9 certificate was bound either to the host name or the IP address of the sever. You must use either the IP or hostname for these settings, depending on what the certificate is bound to in your configuration. For example, for the PDI Authentication Service Site using a hostname bound certificate, change to where hostname is the name of the server and the port number is 333. The server needs to run a port other than 443 and should be changed to Click OK. Paceart Integration Configuration Values This table explains the fields on the General Paceart Settings configuration window. Field Name Explanation General Paceart External System Account Username Password The Paceart External System Account username. This username is defined in Paceart on the External System Accounts tab. The Paceart External System Account password. This password is defined in Paceart on the External System Accounts tab. Paceart Web Services PDI Authentication Service Site PDI Management Service Site PDI Outbound ML Export Service Site PDI Outbound Request Service Site PDI Patient Management Service Site PDI Appointment Management Service Site PDI Outbound Appointment Service Site The URL to access the Authentication Service of the Paceart Domain Interface. The URL to access the Management Service of the Paceart Domain Interface. The URL to access the Outbound ML Export Service of the Paceart Domain Interface. The URL to access the Outbound Request Service of the Paceart Domain Interface. The URL to access the Patient Management Service of the Paceart Domain Interface. The URL to access the Appointment Management Service of the Paceart Domain Interface. The URL to access the Outbound Appointment Service of the Paceart Domain Interface. One-Stop Scheduling The Paceart-CareLink Scheduling Integration feature provides a way to automatically synchronize scheduling between the CareLink Network and the Paceart System. If you schedule an appointment in CareLink, it will be downloaded to the Paceart System; if you schedule an appointment in Paceart, it will be sent to CareLink. Paceart regularly requests status information for appointments scheduled in CareLink. Schedules are either updated nightly or when a clinician makes a request from the Paceart System. If an appointment is created in CareLink, CareLink retains ownership until the appointment is sent to Paceart. Once the Paceart System is updated to reflect the CareLink Network appointment, the appointment is owned by Paceart.
22 20 Connectivity Guide Paceart Integration If a remote appointment is created or modified in Paceart, the appointment is automatically created or updated in CareLink. Ownership of the appointment remains with the Paceart System. Paceart receives appointment status information that reflects the last known status as reported by CareLink. The remote status is displayed in patient appointment information on the Paceart System. Paceart records the completion and failure status details of this information in its log. Paceart scheduling requests that violate CareLink Network scheduling rules are displayed as errors in the Paceart System Remote Status field. When you schedule a remote appointment in Paceart, the Remote Status will show "Processing." Once the appointment is successfully acknowledged by CareLink, the Remote Status will show "Scheduled." If the appointment is not successfully sent to CareLink or if CareLink reports an error, the Remote Status will show "Error." An "Error" status can be manually changed to "Ignore." Once the transmission is received by CareLink, the Remote Status will show "Completed." If CareLink determines that an appointment was missed, the Remote Status will show "Missed". Contact your Paceart technical support specialists regarding support for appointment scheduling transfers on the Medtronic CareLink Network. One-Stop Scheduling Prerequisites Before you configure One-Stop Scheduling you must complete the following prerequisite: On the CareLink website, create an External System Account for Mainspring Data Express and enable the Scheduling Integration feature. Before you use One-Stop Scheduling you must ensure that Paceart patient records and appointments meet the following criteria: The Paceart patient record must have a birth date, a patient ID number, and a patient ID number type. Appointments created or updated in Paceart must have the patient remote follow-up service set to Medtronic CareLink Network, and the patient must have an active Medtronic ICD, ICM, or pacemaker that is supported by the Medtronic CareLink Network. To find out if a device is supported, log into CareLink and click Resources > CareLink Supported Implantable Devices. Paceart/CareLink patient matching for a single patient The primary match is on the patient ID number, patient ID number type, and the birth date. If either of these are not present in the Paceart System, appointments will not be sent to CareLink. If the patient ID number and patient ID number type is not present in the CareLink system, a demographic match is performed. The configurable matching criteria include first name, middle initial, and gender in addition to the last name and birth date which are always used. If the demographic match succeeds, CareLink will record the patient number so future matches will be simpler and quicker. This matching is performed on CareLink and is used when adding, updating and removing appointments, and when updating remote appointment status. Paceart/CareLink patient matching for a batch download In this scenario, the Paceart System downloads a list of all CareLink patients and appointments and then matches CareLink patients to Paceart patients. The primary matching is on the patient ID number, patient ID number type, and the birth date. If the patient ID number and ID number type is not present in the CareLink system a much stricter demographic match is performed. This requires a match on the first name, middle initial, last name, gender, and birth date. Configuring One-Stop Scheduling. To start Mainspring Data Express, go to Start > Programs > Medtronic Mainspring Data Express > Medtronic Mainspring Data Express.
23 Connectivity Guide Paceart Integration 2 2. In the Medtronic Mainspring Data Express window, select One-Stop Scheduling and click Configurations. The Paceart Integration window is displayed. 3. On the One-Stop Scheduling tab enter the applicable values for your CareLink implementation. Refer to the One-Stop Scheduling Configuration Values table for more explanation on the fields. 4. Click OK. One-Stop Scheduling Configuration Values This table explains the fields on the One-Stop Scheduling configuration tab. Field name Explanation CareLink Settings CareLink Scheduling Service CareLink Scheduling Service Site External System Account Name External System Authorization Code Send Patient First Name Send Patient Gender Send Patient Middle Name The name of the CareLink scheduling service that the adapter will use. The default value is "Endpoint_CSA_basicHttpsBinding". The fully qualified path of the CareLink scheduling service that the adapter will use. The default value is " The account name of the dedicated user that will be used to connect to the CareLink Scheduling service. This account name is created and configured on the External System Accounts tab on the CareLink website. The account authorization code that will be used to authenticate the CareLink User ID with the CareLink Scheduling service. This authorization code is created and configured on the External System Accounts tab on the CareLink website. A Boolean value indicating if the Patient First Name value is sent to CareLink. If "True", it will be used by CareLink for patient matching. The default value is "True". A Boolean value indicating if the Patient Gender value is sent to CareLink. If "True", it will be used by CareLink for patient matching. The default value is "True". A Boolean value indicating if the Patient Middle Name value is sent to CareLink. If "True", it will be used by CareLink for patient matching. The default value is "True". Paceart Settings
24 22 Connectivity Guide Paceart Integration Field name Patient ID Description Appointment Resource Explanation The Paceart Patient ID Description to associate with the CareLink Remote Patient ID. The default value is "Default". The Paceart Appointment Resource to associate with CareLink remote appointments. The default value is "Default Resource". Troubleshooting One-Stop Scheduling Troubleshooting scheduling connectivity problems CareLink Verify that the CareLink account used to connect to Mainspring Data Express has a Transmission Permission selection of View changes transmission status from new to viewed. Verify that the CareLink account used to connect to Mainspring Data Express does not have an expired password. If the CareLink clinic has sub-clinics, verify that the CareLink account used to connect to the Medtronic Mainspring Data Express has access to the sub-clinics' patients integrated with Paceart. Verify that you created an External System Account in CareLink. Verify that the created External System Account was configured to include Scheduling Integration external system associations. Verify that scheduling integration has not been unlinked and verify the "Last Connected on" date/time displayed. Go to the CareLink Network website and click Manage My Clinic > Clinic Profile > External Systems Integration. Paceart Verify that the Paceart Database Manager is running. Verify that the Paceart database has a Mainspring Data Express user. Verify the Paceart database password associated with the Mainspring Data Express user. Verify that the patient's Demographics tab in Paceart has the patient remote follow-up service set to Medtronic CareLink Network, and that the patient has a Medtronic ICD or pacemaker that is supported by the Medtronic CareLink Network. To view the CareLink Network supported devices list login to the CareLink website and go to Resources > CareLink Supported Implantable Devices. Verify that the Paceart patient record has a date of birth and a valid patient ID number. Mainspring Data Express Verify that the Mainspring Data Express software and features were properly installed and configured. Verify that the correct CareLink hosting system was entered in the One-Stop Scheduling tab of the Paceart Integration dialog. The CareLink hosting system must match what was entered in the Remote Data Interface tab. To verify this fact the Remote Data Interface feature should be selected in the Medtronic Mainspring Data Express window. Verify that the Connected Systems Gateway service was started. HL7 Integration The Paceart System supports the HL7 protocol which allows Paceart to integrate with your existing HL7-based Electronic Health Record (EHR) and Practice Management Systems. This allows you to import patient demographic information, scheduling information, and interrogated device data that conforms to the IHE IDCO
25 Connectivity Guide Paceart Integration 23 profile into Paceart. And allows you to export transtelephonic, in-clinic, and remote encounter data from Paceart to EHR systems. If you want to integrate Merlin.net into your Paceart System, you can do so with an HL7 ORU message that conforms to the IDCO profile. The information contained in this section assumes an understanding of the HL7 Message Specification and a working knowledge of Paceart. Configuring Paceart HL7 Integration. To start Mainspring Data Express, click Start > Programs > Medtronic Mainspring Data Express > Medtronic Mainspring Data Express. 2. In the Medtronic Mainspring Data Express window, select HL7 Integration and click Configurations. The Paceart Integration configuration window is displayed. 3. In the HL7 Integration tab, enter the values for your configuration. 4. Click OK to close the Paceart Integration configuration window. HL7 Integration Configuration Values This table explains the fields on the HL7 Integration configuration tab. Field name Explanation HL7 Inbound Inbound Communication Queue Used by the implementation to communicate with a third-party HL7 engine. The default value is "HL7Source". Do not change this value. HL7 Outbound Outbound Sending Application Namespace ID Outbound Sending Application Universal ID Outbound Sending Application Universal ID Outbound Sending Facility Namespace ID This field uniquely identifies the sending application among all other applications within the network enterprise. The network enterprise consists of all those applications that participate in the exchange of HL7 messages within the enterprise. Entirely site-defined. This information is included in the MSH segment 3, component. The default value is "Paceart". This field uniquely identifies the sending application among all other applications within the network enterprise. The network enterprise consists of all those applications that participate in the exchange of HL7 messages within the enterprise. Entirely site-defined. This information is included the MSH segment 3, component 2. This field uniquely identifies the sending application among all other applications within the network enterprise. The network enterprise consists of all those applications that participate in the exchange of HL7 messages within the enterprise. Entirely site-defined. This information is included the MSH segment 3, component 3. This field further describes the sending application. Entirely site-defined. This information is included the MSH segment 4, component.
26 24 Connectivity Guide Paceart Integration Field name Explanation The default value is "Medtronic". Outbound Sending Facility Universal ID Outbound Sending Facility Universal ID Outbound Receiving Application Namespace ID Outbound Receiving Application Universal ID Outbound Receiving Application Universal ID Outbound Receiving Facility Namespace ID Outbound Receiving Facility Universal ID Outbound Receiving Facility Universal ID Outbound Processing ID This field further describes the sending application. Entirely site-defined. This information is included the MSH segment 4, component 2. This field further describes the sending application. Entirely site-defined. This information is included the MSH segment 4, component 3. This field uniquely identifies the receiving application among all other applications within the network enterprise. The network enterprise consists of all those applications that participate in the exchange of HL7 messages within the enterprise. Entirely site-defined. This information will be in MSH, field 5, component. This field uniquely identifies the receiving application among all other applications within the network enterprise. The network enterprise consists of all those applications that participate in the exchange of HL7 messages within the enterprise. Entirely site-defined. This information will be in MSH, field 5, component 2. This field uniquely identifies the receiving application among all other applications within the network enterprise. The network enterprise consists of all those applications that participate in the exchange of HL7 messages within the enterprise. Entirely site-defined. This information will be in MSH, field 5, component 3. This field identifies the receiving application among multiple identical instances of the application running on behalf of different organizations. Entirely site-defined. This information will be in MSH, field 6, component. This field identifies the receiving application among multiple identical instances of the application running on behalf of different organizations. Entirely site-defined. This information will be in MSH, field 6, component 2. This field identifies the receiving application among multiple identical instances of the application running on behalf of different organizations. Entirely site-defined. This information will be in MSH, field 6, component 3. Defines in the MSH header whether the message is part of a production, training, or debugging system. "D"=Debugging, "P"=Production, "T"=Training. This information will be in MSH, field, component. The default value is "P".
27 Connectivity Guide Paceart Integration 25 Field name Outbound Processing ID Mode Outbound HL7 Version Outbound Include Episode Observations Outbound Patient Visit Patient Class Outbound Communication Queue Include Nonconforming Data Include IDCO Nonconforming Data Include Medtronic OB Segments Include PV2 Segment Explanation Defines in the MSH header the processing mode. "A"=Archive, "R"=Restore from archive, "I"=Initial load, "T"=Current processing transmitted at intervals. This information will be in MSH, field, component 2. The version of HL7 listed in the HL7 message header. This information will be in MSH, field 2. The default value is "2.3.". Boolean value providing an option to include episode data in the HL7 message sent to the receiving system. Inclusion of this data may add to the size of the message. The default value is "False" (do not send episode data). The default value is"u" and corresponds to a Patient Class of Unknown. This information will be in PV, field 2. Used by the implementation to communicate with a third-party HL7 engine. The default value is "HL7Destination". Boolean value providing an option to include nonconforming data in the HL7 message sent to the receiving system. Inclusion of this data may add to the size of the message. The default value is "True". Boolean value providing an option to include IDCO nonconforming data in the HL7 message sent to the receiving system. Inclusion of this data may add to the size of the message. The default value is "True". Boolean value providing an option to include Medtronic OB segments in the HL7 message sent to the receiving system. Inclusion of this data may add to the size of the message. The default value is "True". Boolean value providing an option to include the PV2 segment in the HL7 message sent to the receiving system. Inclusion of this data may add to the size of the message. The default value is "True". Paceart Paceart ML Version The version of Paceart ML that will be exported from Paceart to HL7. The default value is "7.0".
28 26 Connectivity Guide Paceart Integration Installing the Corepoint Integration Engine If you selected the Paceart HL7 Integration feature, the Corepoint Integration Engine is installed if it is not already installed. If you have a previous version of NeoIntegrate installed, you need to remove it and install the Corepoint Integration Engine. The Corepoint Integration Engine installation is only launched one time. If you cancel the installation or need to re-execute the installation, you must first delete the following file to allow the Corepoint Integration Engine installation to be launched again:c:\program Files\Medtronic\Connected Systems Gateway\HL7SubSystem\Installed. (The path is different if the default destination folder was modified.) During the Corepoint Integration Engine installation, a dialog box may be displayed that states "The installation of Microsoft Visual C Redistributable Package (x86) appears to have failed. Do you want to continue the Installation?". If this dialog box is displayed, click Yes and continue the installation.. On the Corepoint Health Solutions - InstallShield Wizard window, click Next. 2. Read the license agreement. Click Next to accept it. 3. Specify a destination folder. Click Change to change the default location, and then click Next. 4. Select the type of installation you want and click Next. 5. Select the products you want to install. The default selection is Corepoint Integration Engine. Click Next. 6. If your Paceart System uses SessionSync, you have a port conflict. Specify which alternate ports you would like to use, and then click Next. 7. Enter an Administrator password and click Next. 8. Click Install to install the Corepoint Integration Engine. 9. When the installation is complete, you can launch the license manager. If you already have your license string select this option and click Finish. Note: If you do not have your license string deselect the Launch the License Manager option and call Paceart Technical Support for licensing information. After you click Finish, the Log On dialog is displayed. The Medtronic Mainspring Data Express window also opens in front of the Log On dialog. Move the window out of the way. 0. Enter the username and password you specified in step 6, and then click OK.. On the LicenseManager window, click License wizard. The License Wizard starts. 2. Click Next. 3. Select the Request a license using a product key option, and then click Next. 4. On the Machine description dialog box, enter a description of how this license is used, and then click Next. For example, "St. Elsewhere Hospital Production Server" 5. On the Connection and login information dialog box, enter the Web login provided by Operations and Technical Services and connection details and click Next. 6. Click Connect to contact Corepointhealth.com to obtain your license. 7. After you have connected to Corepointhealth.com click Next. 8. Click Finish. 9. On the LicenseManager window, click Exit. 20. After exiting the license manager, you can load the Corepoint Health configuration import/export file. Run the Corepoint Integration Engine Administration console by clicking Start > All Programs > Corepoint Health > Corepoint Integration Engine > Corepoint Integration Engine - Administration. 2. Enter the user name and password you specified when installing the Corepoint Integration Engine and click OK. The Corepoint Integration Engine Administration Console window is displayed.
29 Connectivity Guide Paceart Integration Ensure that the Integration Engine Service is started. 23. Close the Corepoint Integration Engine Administration Console window. 24. Open the Corepoint Integration Engine Configuration console by clicking Start > All Programs > Corepoint Health > Corepoint Integration Engine > Corepoint Integration Engine - Configuration. 25. Enter the user name and password you specified when installing the Corepoint Integration Engine and click OK. The Corepoint Integration Engine Configuration window is displayed. 26. Click File > Import. The Open File window is displayed. 27. Navigate to the configuration file folder at C:\Program Files\Common Files\Medtronic\CSG Shared Files\. 28. Double-click the HL7 Source and Destination Transformation.nix file. The Import selected components window is displayed. 29. Select all of the components and click Import. 30. Click OK after the components have been loaded. 3. Close the Corepoint Integration Engine Configuration window. Paceart Optima HL7 Integration View and Resolving Errors In Paceart Optima you can view and resolve HL7 errors in Administration > Activity Log. The Patient Management service logs all patient information changes from the HL7 protocol. Any additions, deletions, and updates to patient records from HL7-based systems are logged under this service in the Activity Log. In some instances a work item is created and requires a Paceart user or workgroup resolve the issue. For a complete list of Activity Log Results refer to the Paceart Optima System Software User Manual or the Paceart Optima online Help. Paceart Optima Patient ID Configuration In Paceart Optima a patient can have multiple patient IDs. You can configure patient IDs in Administration > Demographics > Patient ID s tab. Matching an inbound patient ID involves matching both the ID number and the ID type. By default Paceart matches the first occurrence of the PID-3 segment to patient ID number and patient ID type. For example, your Paceart Optima System has a patient ID type called "EMR". You receive the following PID segment in an HL7 message: PID ^^^^EMR~65432^^^^MRN This would match a patient in Paceart with an "EMR" type ID and a patient ID number of "335579".
30 28 Connectivity Guide Paceart Integration Paceart Optima Patient Matching Configuration In Paceart Optima you must configure patient matching in Administration > Connectivity > Patient Matching Configuration tab. Patient matching is initially based on the patient ID only. You can configure an additional second level of patient matching in the Verify Patient Match Configuration section. If a patient match cannot be made using the patient ID, you can also configure matching based on patient demographic information. You can configure this matching in the Demographics Only Match Configuration section. This additional and secondary matching can determine when a new patient is created in Paceart, when an error is logged, and when a work item is created. For more information on configuring Paceart Optima patient matching refer to the Paceart Optima System Software User Manual or the Paceart Optima online Help. Inbound Messages Paceart integrates with the HL7 protocol for inbound messages from external systems to Paceart by mapping HL7 values to Paceart parameters. Inbound Patient Administration Messages (ADT) The Medtronic Mainspring Data Express HL7 integration can receive demographic information from any system or interface engine that is using HL7 messaging. This feature allows for consistent patient demographic information across systems and reduces duplication of data entry. The patient administration transaction set provides for the transmission of new or updated demographic information about patients. Information that is entered in a patient administration system can be passed to Paceart as an unsolicited HL7 message. The Medtronic Mainspring Data Express HL7 integration supports a wide array of ADT trigger events to allow you to configure the HL7 integration to capture the desired changes to patient demographic information. Table : Supported HL7 ADT Triggers The Patient Add, Patient Update, or Patient Add-Update Paceart requests can be configured for the A04, A08, and A28 messages. Patient Update is most often used. HL7 Message ADT^A04 ADT^A08 ADT^A28 ADT^A29 ADT^A47 Paceart Request Patient Add Patient Update Patient Add-Update Patient Delete Patient Change ID
31 Connectivity Guide Paceart Integration 29 Table : Patient Processing Paceart Request Patient Add Patient Update Patient Add-Update Patient Delete Patient Change ID Description Adds the patient to Paceart if there is no matching patient record found. Updates the patient record if a single matching patient is found in Paceart. Adds the patient to Paceart if there is no matching patient record found. Updates the patient record if a single matching patient is found in Paceart. Deletes the patient from Paceart only if a single matching patient is found, and the paceart patient record does not have any associated device, encounter, or appointment. Changes the specified patient ID if a single matching patient is found. Inbound Patient Administration Message Segments PID - Patient Identification Segment The PID segment provides important identification information about the patient and is used as the primary means of communicating the identifying and demographic information about a patient between systems. Field Component Sub-component Occurrence Name Paceart values PID-3 Patient ID Value PID-3 5 Patient ID Description PID Patient ID Value PID Patient ID Description PID-5 Patient Last Name PID-5 2 Patient First Name PID-5 3 Patient Middle Initial String PID-7 Patient Date Of Birth PID-8 Patient Gender MALE, FEMALE, OTHER PID- Patient Address Line PID- 2 Patient Address Line 2 PID- 3 Patient Address City
32 30 Connectivity Guide Paceart Integration Field Component Sub-component Occurrence Name Paceart values PID- 4 Patient Address State String 0 PID- 5 Patient Address Postal Code String 0 PID- 6 Patient Address Country PID-3 4 Patient Address String 00 PID-3 Patient Phone Number String 20 PID-4 Patient Phone Number Other String 20 PID-5 Patient Language OTHER, MANDARIN, ENGLISH, HINDI, SPANISH, ARABIC, RUSSIAN, PORTUGUESE, BENGALI, MALAY_INDONESIAN, FRENCH, JAPANESE, GERMAN, FARSI_PERSIAN, URDU, PUNJABI, VIETNAMESE, TAMIL, WU, JAVANESE, TURKISH, TELUGU, KOREAN, MARATHI, ITALIAN, THAI, CANTONESE, GUJARATI, POLISH, KANNADA, BURMESE PID-6 Patient Marital Status MARRIED, SINGLE, WIDOWED, DIVORCED, SEPARATED, UNDETERMINED, OTHER PV - Patient Visit Information The PV segment is used by registration applications to communicate information on a visit-specific basis.
33 Connectivity Guide Paceart Integration 3 Field Component Sub-component Occurrence Name Paceart values PV-2 Patient Status String PV-3 Patient of Care Reference_Only PV2 - Patient Visit Information The PV2 segment is a continuation of visit-specific information contained in the PV segment. Field Component Sub-component Occurrence Name Paceart values PV2-7 Patient Code Value String 6 PV2-7 2 Patient Code Value 2 String 6 PV2-7 3 Patient Code Value 3 String 6 PV2-7 4 Patient Code Value 4 String 6 MRG - Merge Patient Identification Segment The MRG segment provides receiving applications with information necessary to initiate the merging of patient data as well as groups of records Field Component Sub-component Occurrence Name Paceart values MRG- Patient ID Value MRG- 5 Patient ID Description Inbound Scheduling Messages (SIU) The Medtronic Mainspring Data Express HL7 integration can accept unsolicited schedule notification messages (SIU) from a scheduling filler application. The HL7 standard defines four roles that the system can assume in scheduling integration. Paceart operates as an Auxiliary application or an "interested third-party." This allows for existing scheduling systems to serve as the Filler application and to send schedule notification messages to the Paceart System. The Filler application is said to own the schedule for the specified resources meaning it is the authoritative source for scheduling information. Supported Transaction s The schedule notification messages can be processed to not only create, delete, cancel, and modify appointments in Paceart, but also can be used to add or modify patient information. This allows for a patient to be added to Paceart based on their first appointment with a clinic.
34 32 Connectivity Guide Paceart Integration Updating, rescheduling, deleting, or canceling, an appointment can only be performed as long as the appointment exists in Paceart. A single matching Paceart appointment for a single matching patient is said to exist if the Appointment External ID is the same as the Request Appointment External ID (matching appointment is found by ID) or there is an appointment with the same start date, time, and appointment type (matching appointment is found by start date, time, and type). Table : Supported SIU Triggers HL7 Message SIU^S2 SIU^S3 SIU^S4 SIU^S5 SIU^S7 Paceart Request Add Appointment Update Appointment Add Update Appointment Cancel Appointment Delete Appointment Table : Appointment Processing Paceart Request Add Appointment Update Appointment Add Update Appointment Cancel Appointment Delete Appointment Description Creates a new appointment in Paceart if the appointment ID does not already exist in Paceart. If the appointment does exist then no appointment will be added. Modifies the appointment in Paceart if the appointment ID already exists in Paceart. Updates the appointment information in Paceart if the appointment exists in Paceart. If the appointment does not exist in Paceart, then it creates a new appointment in Paceart. Cancels/Removes the appointment in Paceart if the appointment ID already exists in Paceart. Deletes the appointment in Paceart if the appointment ID already exists in Paceart. Inbound Scheduling Segments The schedule notification message should contain information on what type of appointment has been booked. The information can be transformed in the message to map to one of the following values. If no encounter type information is available in the scheduling messages, the appointment will fail to add/update the Paceart database. SCH - Schedule Activity Information The SCH segment contains general information about a scheduled appointment. Table : Field Component Sub-component Occurrence Name Paceart values SCH- Appointment ID String 75
35 Connectivity Guide Paceart Integration 33 Field Component Sub-component Occurrence Name Paceart values SCH-2 Appointment External ID String 75, cannot contain characters [, _, and % SCH-8 Appointment INCLINIC, TTM, REMOTE, MISCELLANEOUS, IMPLANT SCH-9 Appointment Duration TimeSpan(00:0,.00:00) SCH- 4 Appointment Start Date Time SCH-25 Appointment Remote Status PROCESSING, SCHEDULED, ERROR, COMPLETED, MISSED, IGNORED, PENDING NTE - Notes and Comments The NTE segment is an optional segment used to provide notes and comments. Field Component Sub-component Occurrence Name Paceart values NTE-3 Appointment Comment String 255 PID - Patient Identification Segment The PID segment provides important identification information about the patient and is used as the primary means of communicating the identifying and demographic information about a patient between systems. Field Component Sub-component Occurrence Name Paceart values PID-3 Patient ID Value PID-3 5 Patient ID Description PID Patient ID Value PID Patient ID Description PID-5 Patient Last Name PID-5 2 Patient First Name
36 34 Connectivity Guide Paceart Integration Field Component Sub-component Occurrence Name Paceart values PID-5 3 Patient Middle Initial String PID-7 Patient Date Of Birth PID-8 Patient Gender MALE, FEMALE, OTHER PID- Patient Address Line PID- 2 Patient Address Line 2 PID- 3 Patient Address City PID- 4 Patient Address State String 0 PID- 5 Patient Address Postal Code String 0 PID- 6 Patient Address Country PID-3 4 Patient Address String 00 PID-3 Patient Phone Number String 20 PID-4 Patient Phone Number Other String 20 PID-5 Patient Language OTHER, MANDARIN, ENGLISH, HINDI, SPANISH, ARABIC, RUSSIAN, PORTUGUESE, BENGALI, MALAY_INDONESIAN, FRENCH, JAPANESE, GERMAN, FARSI_PERSIAN, URDU, PUNJABI, VIETNAMESE, TAMIL, WU, JAVANESE, TURKISH, TELUGU, KOREAN, MARATHI, ITALIAN, THAI,
37 Connectivity Guide Paceart Integration 35 Field Component Sub-component Occurrence Name Paceart values CANTONESE, GUJARATI, POLISH, KANNADA, BURMESE PID-6 Patient Marital Status MARRIED, SINGLE, WIDOWED, DIVORCED, SEPARATED, UNDETERMINED, OTHER PV - Patient Visit Information The PV segment is used by registration applications to communicate information on a visit-specific basis. Field Component Sub-component Occurrence Name Paceart values PV-2 Patient Status String PV-3 Patient of Care Reference_Only PV-9 Appointment Visit ID PV2 - Patient Visit Information The PV2 segment is a continuation of visit-specific information contained in the PV segment. Field Component Sub-component Occurrence Name Paceart values PV2-7 Patient Code Value String 6 PV2-7 2 Patient Code Value 2 String 6 PV2-7 3 Patient Code Value 3 String 6 PV2-7 4 Patient Code Value 4 String 6 AIG - General Resource Segment The AIG segment contains information about various kinds of resources that can be scheduled. Field Component Sub-component Occurrence Name Paceart values AIG-3 Appointment Resource Reference_Only
38 36 Connectivity Guide Paceart Integration Inbound Observation Requests (ORU) The ORU-R0 message transmits observations and results. Mainspring Data Express and Paceart Optima comply with the IDCO standard for how to use an HL7 ORU message for implantable cardiac device observations. Table : Supported HL7 ORU Triggers HL7 Message ORU^R0 Paceart Request Transmission Data Paceart Request Transmission Data Description Sends transmission data from one system to another system. Inbound Observation Requests Segments MSH - Message Header The MSH segment is present in every HL7 message type and defines the message's source, purpose, destination, and certain syntax specifics like delimiters (separator characters) and character sets. Field Component Sub-component Occurrence Name Paceart values MSH-3 Sending Application ID String 00 MSH-4 Sending Application Sub ID String 00 PID - Patient Identification Segment The PID segment provides important identification information about the patient and is used as the primary means of communicating the identifying and demographic information about a patient between systems. Field Component Sub-component Occurrence Name Paceart values PID Patient ID Value PID-3 4 Session Device Manufacturer MDC_IDC MFG_ANG MDC_IDC MFG_APC MDC_IDC MFG_BIO MDC_IDC MFG_BSC MDC_IDC MFG_CCS MDC_IDC MFG_CIM MDC_IDC MFG_CPM MDC_IDC MFG_CKP
39 Connectivity Guide Paceart Integration 37 Field Component Sub-component Occurrence Name Paceart values MDC_IDC MFG_CATM MDC_IDC MFG_COR MDC_IDC MFG_ELA MDC_IDC MFG_GDT MDC_IDC MFG_IMC MDC_IDC MFG_MCO MDC_IDC MFG_MDT MDC_IDC MFG_OSC MDC_IDC MFG_PCS MDC_IDC MFG_SIE MDC_IDC MFG_SOR MDC_IDC MFG_SJM MDC_IDC MFG_TEL MDC_IDC MFG_VEN MDC_IDC MFG_VIT PID Patient ID Description PID-5 Patient Last Name PID-5 2 Patient First Name PID-5 3 Patient Middle Initial String PID-7 Patient Date Of Birth PID-8 Patient Gender MALE, FEMALE, OTHER PID- Patient Address Line PID- 2 Patient Address Line 2 PID- 3 Patient Address City
40 38 Connectivity Guide Paceart Integration Field Component Sub-component Occurrence Name Paceart values PID- 4 Patient Address State String 0 PID- 5 Patient Address Postal Code String 0 PID- 6 Patient Address Country PV - Patient Visit Information The PV segment is used by registration applications to communicate information on a visit-specific basis. Field Component Sub-component Occurrence Name Paceart values PV-2 Patient Status String PV-9 Appointment Visit ID OBR - Observation Request The OBR segment transmits information about an exam, diagnostic study/observation, or assessment that is specific to an order or result. Field Component Sub-component Occurrence Name Paceart values OBR-3 Sending Application Event ID String 00 OBR-4 IMPLANT, INCLINIC, REMOTE, TTM, PHONENOTE, MISC, PROGRAMMING OBR-7 Transmission Date and Time OB - Observation Mapping The OB segment is primarily used to carry key clinical observation and result reporting information within report messages.
41 Connectivity Guide Paceart Integration 39 Table : MDC_IDC_PG IDCO Paceart OB OB 3-2 IDCO Supported Values OB-5 3- Name MDC_IDC_PG_TYPE ^MDC_IDC PG_TYPE_IPG^MDC Device ^MDC_IDC PG_TYPE_ICD^MDC ^MDC_IDC PG_TYPE_CRT_D^MDC ^MDC_IDC PG_TYPE_CRT_P^MDC ^MDC_IDC PG_TYPE_Monitor^MDC MDC_IDC_PG_MODEL Device Model MDC_IDC_PG_SERIAL Device Serial String 20 Number MDC_IDC_PG_MFG ^MDC_IDC MFG_ANGN^MDC Device ^MDC_IDC MFG_APC^MDC Manufacturer 75373^MDC_IDC MFG_BIO^MDC ^MDC_IDC MFG_BS^MDC ^MDC_IDC MFG_CCS^MDC ^MDC_IDC MFG_CIM^MDC ^MDC_IDC MFG_CPM^MDC ^MDC_IDC MFG_CKP^MDC ^MDC_IDC MFG_CATM^MDC ^MDC_IDC MFG_COR^MDC ^MDC_IDC MFG_ELA^MDC ^MDC_IDC MFG_GDT^MDC 75374^MDC_IDC MFG_IMC^MDC ^MDC_IDC MFG_IMT^MDC ^MDC_IDC MFG_MCO^MDC ^MDC_IDC MFG_MDT^MDC ^MDC_IDC MFG_OSC^MDC ^MDC_IDC MFG_OSY^MDC ^MDC_IDC MFG_PCS^MDC ^MDC_IDC MFG_SIE^MDC ^MDC_IDC MFG_SOM^MDC ^MDC_IDC MFG_SOR^MDC 75375^MDC_IDC MFG_J^MDC ^MDC_IDC MFG_O^MDC ^MDC_IDC MFG_TEL^MDC
42 40 Connectivity Guide Paceart Integration IDCO Paceart OB OB 3-2 IDCO Supported Values OB-5 3- Name ^MDC_IDC MFG_VEN^MDC ^MDC_IDC MFG_VIT^MDC Table : MDC_IDC_SESS IDCO Paceart OB OB 3-2 Supported Values (OB 5) 3- Name MDC_IDC_SESS_ 75520^MDC_IDC SESS_REPROGRAMMED_YES^MDC REPROGRAMMED ^MDC_IDC SESS_REPROGRAMMED_NO^MDC Session Reprogrammed ^MDC_IDC SESS_REPROGRAMMED_Unknown^MDC Table : MDC_IDC_MSMT IDCO Paceart OB OB 3-2 Supported Values (OB 5) Name MDC_IDC_MSMT_BATTERY_DTM Measured Device Battery Timestamp MDC_IDC_MSMT_BATTERY_ATUS 7543^MDC_IDC BATTERY_ATUS_BOS^MDC 7544^MDC_IDC BATTERY_ATUS_EOS^MDC Measured Device Battery Status 7545^MDC_IDC BATTERY_ATUS_RRT^MDC 7546^MDC_IDC BATTERY_ATUS_MOS^MDC 7547^MDC_IDC BATTERY_ATUS_ Unknown^MDC MDC_IDC_MSMT_BATTERY_VOLTAGE Measured Device Battery Voltage MDC_IDC_MSMT_BATTERY_IMPEDANCE Measured Device Battery Impedance MDC_IDC_MSMT_BATTERY_REMAINING_ Integer LONGEVITY Measured Device Battery Remaining Longevity MDC_IDC_MSMT_BATTERY_REMAINING_ PERCENTAGE Measured Device Battery Remaining Percentage
43 Connectivity Guide Paceart Integration 4 IDCO Paceart OB OB 3-2 Supported Values (OB 5) Name MDC_IDC_MSMT_BATTERY_RRT_TRIGGER Measured Device Battery Status RRT Trigger when 72856^MDC_IDC_MSMT_CAP_CHARGE_TYPE^MDC has OB-5 value of 75477^MDC_IDC CHARGE_TYPE_^MDC MDC_IDC_MSMT_CAP_CHARGE_DTM Measured Device Capacitor Last Full Energy Charge Timestamp or Measured Device Capacitor Last Charge Timestamp MDC_IDC_MSMT_CAP_CHARGE_TIME Measured Device Capacitor Last Full Energy Charge Interval or Measured Device Capacitor Last Charge Interval MDC_IDC_MSMT_CAP_CHARGE_ENERGY Measured Device Capacitor Last Full Energy Charge or Measured Device Capacitor Last Charge Energy when 72856^MDC_IDC_MSMT_CAP_CHARGE_TYPE^MDC has OB-5 value of 5477^MDC_IDC CHARGE_TYPE_Reformation^MDC MDC_IDC_MSMT_CAP_CHARGE_DTM Measured Device Capacitor Last Reformation Timestamp MDC_IDC_MSMT_CAP_CHARGE_TIME Measured Device Capacitor Last Reformation Interval MDC_IDC_MSMT_CAP_CHARGE_ENERGY Measured Device
44 42 Connectivity Guide Paceart Integration IDCO Paceart OB OB 3-2 Supported Values (OB 5) Name 3- Capacitor Last Reformation Energy MDC_IDC_MSMT_CAP_CHARGE_TYPE 75477^MDC_IDC CHARGE_TYPE_^MDC Determines which 75478^MDC_IDC CHARGE_TYPE_ Reformation^MDC parameter is used when mapping the above three rows ^MDC_IDC CHARGE_TYPE_Unknown^MDC 7292 MDC_IDC_MSMT_LEADCHNL_RA_DTM_ ART Measured Right Atrium Lead Low Power Channel Sensing Integrity Counter Start Date MDC_IDC_MSMT_LEADCHNL_RA_DTM_END Measured Right Atrium Lead Low Power Channel Sensing Integrity Counter End Date MDC_IDC_MSMT_LEADCHNL_RV_DTM_ ART Measured Right Ventricle Lead Low Power Channel Sensing Integrity Counter Start Date MDC_IDC_MSMT_LEADCHNL_RV_DTM_END Measured Right Ventricle Lead Low Power Channel Sensing Integrity Counter End Date MDC_IDC_MSMT_LEADCHNL_LA_DTM_ ART MDC_IDC_MSMT_LEADCHNL_LA_DTM_END MDC_IDC_MSMT_LEADCHNL_LV_DTM_ ART Measured Left Ventricle Lead Low Power Channel Sensing Integrity Counter Start Date MDC_IDC_MSMT_LEADCHNL_LV_DTM_END Measured Left Ventricle Lead Low Power Channel
45 Connectivity Guide Paceart Integration 43 IDCO Paceart OB OB 3-2 Supported Values (OB 5) Name 3- Sensing Integrity Counter End Date MDC_IDC_MSMT_LEADCHNL_RA_LEAD_ 75424^MDC_IDC CHANNEL_ATUS_ CHANNEL_ATUS CheckLead^MDC Measured Right ^MDC_IDC CHANNEL_ATUS_Null^MDC Atrium Lead Low Power Channel Status MDC_IDC_MSMT_LEADCHNL_RV_LEAD_ 75424^MDC_IDC CHANNEL_ATUS_ CHANNEL_ATUS CheckLead^MDC Measured Right ^MDC_IDC CHANNEL_ATUS_Null^MDC Ventricle Lead Low Power Channel Status MDC_IDC_MSMT_LEADCHNL_LA_LEAD_ 75424^MDC_IDC CHANNEL_ATUS_ CHANNEL_ATUS CheckLead^MDC ^MDC_IDC CHANNEL_ATUS_Null^MDC MDC_IDC_MSMT_LEADCHNL_LV_LEAD_ 75424^MDC_IDC CHANNEL_ATUS_ CHANNEL_ATUS CheckLead^MDC Measured Left ^MDC_IDC CHANNEL_ATUS_Null^MDC Ventricle Lead Low Power Channel Status MDC_IDC_MSMT_LEADCHNL_RA_SENSING_ INTR_AMPL MDC_IDC_MSMT_LEADCHNL_RA_SENSING_ INTR_AMPL_MA Bradycardia Right Atrium Sensing Amplitude MDC_IDC_MSMT_LEADCHNL_RA_SENSING_ INTR_AMPL_MIN MDC_IDC_MSMT_LEADCHNL_RA_SENSING_ INTR_AMPL_MEAN MDC_IDC_MSMT_LEADCHNL_RV_SENSING_ INTR_AMPL MDC_IDC_MSMT_LEADCHNL_RV_SENSING_ INTR_AMPL_MA Bradycardia Right Ventricle Sensing Amplitude MDC_IDC_MSMT_LEADCHNL_RV_SENSING_ INTR_AMPL_MIN MDC_IDC_MSMT_LEADCHNL_RV_SENSING_ INTR_AMPL_MEAN MDC_IDC_MSMT_LEADCHNL_LA_SENSING_ INTR_AMPL MDC_IDC_MSMT_LEADCHNL_LA_SENSING_ INTR_AMPL_MA MDC_IDC_MSMT_LEADCHNL_LA_SENSING_ INTR_AMPL_MIN
46 44 Connectivity Guide Paceart Integration IDCO Paceart OB OB 3-2 Supported Values (OB 5) Name MDC_IDC_MSMT_LEADCHNL_LA_SENSING_ INTR_AMPL_MEAN MDC_IDC_MSMT_LEADCHNL_LV_SENSING_ INTR_AMPL MDC_IDC_MSMT_LEADCHNL_LV_SENSING_ INTR_AMPL_MA Bradycardia Left Ventricle Sensing Amplitude MDC_IDC_MSMT_LEADCHNL_LV_SENSING_ INTR_AMPL_MIN MDC_IDC_MSMT_LEADCHNL_LV_SENSING_ INTR_AMPL_MEAN 7222 MDC_IDC_MSMT_LEADCHNL_RA_SENSING_ ^MDC_IDC POLARITY_UNI^MDC POLARITY ^MDC_IDC POLARITY_BI^MDC Measured Right Atrium Lead ^MDC_IDC POLARITY_Unknown^MDC Sensing Threshold Polarity 7223 MDC_IDC_MSMT_LEADCHNL_RV_SENSING_ ^MDC_IDC POLARITY_UNI^MDC POLARITY ^MDC_IDC POLARITY_BI^MDC Measured Right Ventricle Lead ^MDC_IDC POLARITY_Unknown^MDC Sensing Threshold Polarity 7224 MDC_IDC_MSMT_LEADCHNL_LA_SENSING_ ^MDC_IDC POLARITY_UNI^MDC POLARITY ^MDC_IDC POLARITY_BI^MDC ^MDC_IDC POLARITY_Unknown^MDC 7225 MDC_IDC_MSMT_LEADCHNL_LV_SENSING_ ^MDC_IDC POLARITY_UNI^MDC POLARITY ^MDC_IDC POLARITY_BI^MDC Measured Left Ventricle Lead ^MDC_IDC POLARITY_Unknown^MDC Sensing Threshold Polarity MDC_IDC_MSMT_LEADCHNL_RA_PACING_ THRESHOLD_AMPLITUDE Measured Right Atrium Lead Capture Threshold Amplitude MDC_IDC_MSMT_LEADCHNL_RV_PACING_ THRESHOLD_AMPLITUDE Measured Right Ventricle Lead Capture Threshold Amplitude MDC_IDC_MSMT_LEADCHNL_LA_PACING_ THRESHOLD_AMPLITUDE MDC_IDC_MSMT_LEADCHNL_LV_PACING_ THRESHOLD_AMPLITUDE Measured Left Ventricle Lead
47 Connectivity Guide Paceart Integration 45 IDCO Paceart OB OB 3-2 Supported Values (OB 5) Name 3- Capture Threshold Amplitude MDC_IDC_MSMT_LEADCHNL_RA_PACING_ THRESHOLD_PULSEWIDTH Measured Right Atrium Lead Capture Threshold Duration MDC_IDC_MSMT_LEADCHNL_RV_PACING_ THRESHOLD_PULSEWIDTH Measured Right Ventricle Lead Capture Threshold Duration MDC_IDC_MSMT_LEADCHNL_LA_PACING_ THRESHOLD_PULSEWIDTH MDC_IDC_MSMT_LEADCHNL_LV_PACING_ THRESHOLD_PULSEWIDTH Measured Left Ventricle Lead Capture Threshold Duration MDC_IDC_MSMT_LEADCHNL_RA_PACING_ ^MDC_IDC MEASUREMENT_METHOD_ THRESHOLD_MEASUREMENT_METHOD ProgrammerManual^MDC Measured Right ^MDC_IDC MEASUREMENT_METHOD_ ProgrammerAutomatic^MDC Atrium Lead Capture Threshold Measurement 75437^MDC_IDC MEASUREMENT_METHOD_ Method DeviceAutomatic^MDC MDC_IDC_MSMT_LEADCHNL_RV_PACING_ ^MDC_IDC MEASUREMENT_METHOD_ THRESHOLD_MEASUREMENT_METHOD ProgrammerManual^MDC Measured Right ^MDC_IDC MEASUREMENT_METHOD_ ProgrammerAutomatic^MDC Ventricle Lead Capture Threshold Measurement 75437^MDC_IDC MEASUREMENT_METHOD_ Method DeviceAutomatic^MDC MDC_IDC_MSMT_LEADCHNL_LA_PACING_ ^MDC_IDC MEASUREMENT_METHOD_ THRESHOLD_MEASUREMENT_METHOD ProgrammerManual^MDC ^MDC_IDC MEASUREMENT_METHOD_ ProgrammerAutomatic^MDC 75437^MDC_IDC MEASUREMENT_METHOD_ DeviceAutomatic^MDC MDC_IDC_MSMT_LEADCHNL_LV_PACING_ ^MDC_IDC MEASUREMENT_METHOD_ THRESHOLD_MEASUREMENT_METHOD ProgrammerManual^MDC Measured Left ^MDC_IDC MEASUREMENT_METHOD_ ProgrammerAutomatic^MDC Ventricle Lead Capture Threshold Measurement 75437^MDC_IDC MEASUREMENT_METHOD_ Method DeviceAutomatic^MDC
48 46 Connectivity Guide Paceart Integration IDCO Paceart OB OB 3-2 Supported Values (OB 5) Name MDC_IDC_MSMT_LEADCHNL_RA_PACING_ ^MDC_IDC POLARITY_UNI^MDC THRESHOLD_POLARITY ^MDC_IDC POLARITY_BI^MDC Measured Right Atrium Lead ^MDC_IDC POLARITY_Unknown^MDC Capture Threshold Polarity MDC_IDC_MSMT_LEADCHNL_RV_PACING_ ^MDC_IDC POLARITY_UNI^MDC THRESHOLD_POLARITY ^MDC_IDC POLARITY_BI^MDC Measured Right Ventricle Lead ^MDC_IDC POLARITY_Unknown^MDC Capture Threshold Polarity MDC_IDC_MSMT_LEADCHNL_LA_PACING_ ^MDC_IDC POLARITY_UNI^MDC THRESHOLD_POLARITY ^MDC_IDC POLARITY_BI^MDC ^MDC_IDC POLARITY_Unknown^MDC MDC_IDC_MSMT_LEADCHNL_LV_PACING_ ^MDC_IDC POLARITY_UNI^MDC THRESHOLD_POLARITY ^MDC_IDC POLARITY_BI^MDC Measured Left Ventricle Lead ^MDC_IDC POLARITY_Unknown^MDC Capture Threshold Polarity MDC_IDC_MSMT_LEADCHNL_RA_ IMPEDANCE_VALUE Measured Right Atrium Lead Low Power Channel Impedance Measurement Value MDC_IDC_MSMT_LEADCHNL_RV_ IMPEDANCE_VALUE Measured Right Ventricle Lead Low Power Channel Impedance Measurement Value MDC_IDC_MSMT_LEADCHNL_LA_ IMPEDANCE_VALUE MDC_IDC_MSMT_LEADCHNL_LV_ IMPEDANCE_VALUE Measured Left Ventricle Lead Low Power Channel Impedance Measurement Value MDC_IDC_MSMT_LEADCHNL_RA_ ^MDC_IDC POLARITY_UNI^MDC IMPEDANCE_POLARITY ^MDC_IDC POLARITY_BI^MDC Measured Right Atrium Lead Low ^MDC_IDC POLARITY_Unknown^MDC Power Channel Impedance Polarity
49 Connectivity Guide Paceart Integration 47 IDCO Paceart OB OB 3-2 Supported Values (OB 5) Name MDC_IDC_MSMT_LEADCHNL_RV_ ^MDC_IDC POLARITY_UNI^MDC IMPEDANCE_POLARITY ^MDC_IDC POLARITY_BI^MDC Measured Right Ventricle Lead Low ^MDC_IDC POLARITY_Unknown^MDC Power Channel Impedance Polarity MDC_IDC_MSMT_LEADCHNL_LA_ ^MDC_IDC POLARITY_UNI^MDC? IMPEDANCE_POLARITY ^MDC_IDC POLARITY_BI^MDC ^MDC_IDC POLARITY_Unknown^MDC MDC_IDC_MSMT_LEADCHNL_LV_ ^MDC_IDC POLARITY_UNI^MDC IMPEDANCE_POLARITY ^MDC_IDC POLARITY_BI^MDC Measured Left Ventricle Lead Low ^MDC_IDC POLARITY_Unknown^MDC Power Channel Impedance Polarity MDC_IDC_MSMT_LEADHVCHNL_DTM Measured Right Ventricle Lead High Power Channel Impedance Start Date MDC_IDC_MSMT_LEADHVCHNL_DTM_ART Measured Right Ventricle Lead High Power Channel Impedance Start Date MDC_IDC_MSMT_LEADHVCHNL_DTM_END Measured Right Ventricle Lead High Power Channel Impedance End Date MDC_IDC_MSMT_LEADHVCHNL_IMPEDANCE Measured Right Ventricle Lead High Power Channel Impedance Measurement Value
50 48 Connectivity Guide Paceart Integration Table : MDC_IDC_SET IDCO Paceart OB OB 3-2 Supported Values (OB 5) 3- Name MDC_IDC_SET_CRT_LVRV_DELAY VV Delay MDC_IDC_SET_CRT_PACED_CHAMBERS ^MDC_IDC CRT_PACED_CHAMBERS_ RV_Only^MDC ^MDC_IDC CRT_PACED_CHAMBERS_ LV_Only^MDC Heart Failure Ventricular Pacing ^MDC_IDC CRT_PACED_CHAMBERS_ Configuration BiV^MDC MDC_IDC_SET_LEADCHNL_RA_SENSING_ SENSITIVITY Bradycardia Right Atrium Sensing Amplitude MDC_IDC_SET_LEADCHNL_RA_SENSING_ POLARITY ^MDC_IDC POLARITY_UNI^MDC ^MDC_IDC POLARITY_BI^MDC Bradycardia Right Atrium Sensing Polarity MDC_IDC_SET_LEADCHNL_RA_SENSING_ ADAPTATION_MODE ^MDC_IDC SENSING_ADAPTATION_ MODE_AdaptiveSensing^MDC ^MDC_IDC SENSING_ADAPTATION_ MODE_FixedPacing^MDC Bradycardia Right Atrium Sensing Amplitude Adaptation Mode MDC_IDC_SET_LEADCHNL_RA_SENSING_ ANODE_LOCATION_ ^MDC_IDC ELECTRODE_LOCATION_ RA^MDC MDC_IDC_SET_LEADCHNL_RA_SENSING_ ^MDC_IDC ELECTRODE_LOCATION_ ANODE_LOCATION_2 RV^MDC MDC_IDC_SET_LEADCHNL_RA_SENSING_ ^MDC_IDC ELECTRODE_LOCATION_ ANODE_LOCATION_3 LA^MDC Bradycardia Right Atrium Sensing MDC_IDC_SET_LEADCHNL_RA_SENSING_ ANODE_LOCATION_3 MDC_IDC_SET_LEADCHNL_RA_SENSING_ CATHODE_LOCATION_2 MDC_IDC_SET_LEADCHNL_RA_SENSING_ CATHODE_LOCATION_ ^MDC_IDC ELECTRODE_LOCATION_ LV^MDC 75450^MDC_IDC ELECTRODE_LOCATION_ SVC^MDC ^MDC_IDC ELECTRODE_LOCATION_ Unknown^MDC
51 Connectivity Guide Paceart Integration 49 IDCO Paceart OB OB 3-2 Supported Values (OB 5) 3- Name MDC_IDC_SET_LEADCHNL_RA_SENSING_ ANODE_ELECTRODE_ MDC_IDC_SET_LEADCHNL_RA_SENSING_ ANODE_ELECTRODE_ ^MDC_IDC ELECTRODE_NAME_Tip^MDC ^MDC_IDC ELECTRODE_NAME_ Ring^MDC ^MDC_IDC ELECTRODE_NAME_ Bradycardia Right Atrium Sensing MDC_IDC_SET_LEADCHNL_RA_SENSING_ Ring^MDC ANODE_ELECTRODE_ ^MDC_IDC ELECTRODE_NAME_ MDC_IDC_SET_LEADCHNL_RA_SENSING_ Ring2^MDC CATHODE_ELECTRODE_ ^MDC_IDC ELECTRODE_NAME_ MDC_IDC_SET_LEADCHNL_RA_SENSING_ Ring3^MDC CATHODE_ELECTRODE_ ^MDC_IDC ELECTRODE_NAME_ MDC_IDC_SET_LEADCHNL_RA_SENSING_ CATHODE_ELECTRODE_3 Ring4^MDC ^MDC_IDC ELECTRODE_NAME_Coil^MDC ^MDC_IDC ELECTRODE_NAME_ SubQPatch^MDC ^MDC_IDC ELECTRODE_NAME_Can^MDC ^MDC_IDC ELECTRODE_NAME_ Unknown^MDC MDC_IDC_SET_LEADCHNL_RV_SENSING_ SENSITIVITY Bradycardia Right Ventricle Sensing Amplitude MDC_IDC_SET_LEADCHNL_RV_SENSING_ POLARITY ^MDC_IDC POLARITY_UNI^MDC ^MDC_IDC POLARITY_BI^MDC Bradycardia Right Ventricle Sensing Polarity MDC_IDC_SET_LEADCHNL_RV_SENSING_ ADAPTATION_MODE ^MDC_IDC SENSING_ADAPTATION_ MODE_AdaptiveSensing^MDC ^MDC_IDC SENSING_ADAPTATION_ MODE_FixedPacing^MDC Bradycardia Right Ventricle Sensing Amplitude Adaptation Mode MDC_IDC_SET_LEADCHNL_RV_SENSING_ ANODE_LOCATION_ ^MDC_IDC ELECTRODE_LOCATION_ RA^MDC MDC_IDC_SET_LEADCHNL_RV_SENSING_ ^MDC_IDC ELECTRODE_LOCATION_ ANODE_LOCATION_2 RV^MDC MDC_IDC_SET_LEADCHNL_RV_SENSING_ ^MDC_IDC ELECTRODE_LOCATION_ ANODE_LOCATION_3 LA^MDC Bradycardia Right Ventricle Sensing MDC_IDC_SET_LEADCHNL_RV_SENSING_ CATHODE_LOCATION_ ^MDC_IDC ELECTRODE_LOCATION_ LV^MDC
52 50 Connectivity Guide Paceart Integration IDCO Paceart OB OB 3-2 Supported Values (OB 5) 3- Name MDC_IDC_SET_LEADCHNL_RV_SENSING_ 75450^MDC_IDC ELECTRODE_LOCATION_ CATHODE_LOCATION_2 SVC^MDC 7298 MDC_IDC_SET_LEADCHNL_RV_SENSING_ ^MDC_IDC ELECTRODE_LOCATION_ CATHODE_LOCATION_3 Unknown^MDC MDC_IDC_SET_LEADCHNL_RV_SENSING_ ANODE_ELECTRODE_ MDC_IDC_SET_LEADCHNL_RV_SENSING_ ANODE_ELECTRODE_ ^MDC_IDC ELECTRODE_NAME_Tip^MDC ^MDC_IDC ELECTRODE_NAME_ Ring^MDC ^MDC_IDC ELECTRODE_NAME_ Bradycardia Right Ventricle Sensing MDC_IDC_SET_LEADCHNL_RV_SENSING_ Ring^MDC ANODE_ELECTRODE_ ^MDC_IDC ELECTRODE_NAME_ MDC_IDC_SET_LEADCHNL_RV_SENSING_ Ring2^MDC CATHODE_ELECTRODE_ ^MDC_IDC ELECTRODE_NAME_ MDC_IDC_SET_LEADCHNL_RV_SENSING_ Ring3^MDC CATHODE_ELECTRODE_ ^MDC_IDC ELECTRODE_NAME_ MDC_IDC_SET_LEADCHNL_RV_SENSING_ CATHODE_ELECTRODE_3 Ring4^MDC ^MDC_IDC ELECTRODE_NAME_Coil^MDC ^MDC_IDC ELECTRODE_NAME_ SubQPatch^MDC ^MDC_IDC ELECTRODE_NAME_Can^MDC ^MDC_IDC ELECTRODE_NAME_ Unknown^MDC MDC_IDC_SET_LEADCHNL_LV_SENSING_ SENSITIVITY Bradycardia Left Ventricle Sensing Amplitude MDC_IDC_SET_LEADCHNL_LV_SENSING_ POLARITY ^MDC_IDC POLARITY_UNI^MDC ^MDC_IDC POLARITY_BI^MDC Bradycardia Right Ventricle Sensing Polarity MDC_IDC_SET_LEADCHNL_LV_SENSING_ ADAPTATION_MODE ^MDC_IDC SENSING_ADAPTATION_ MODE_AdaptiveSensing^MDC ^MDC_IDC SENSING_ADAPTATION_ MODE_FixedPacing^MDC Bradycardia Left Ventricle Sensing Amplitude Adaptation Mode MDC_IDC_SET_LEADCHNL_LV_SENSING_ ANODE_LOCATION_ ^MDC_IDC ELECTRODE_LOCATION_ RA^MDC MDC_IDC_SET_LEADCHNL_LV_SENSING_ ^MDC_IDC ELECTRODE_LOCATION_ ANODE_LOCATION_2 RV^MDC Bradycardia Left Ventricle
53 Connectivity Guide Paceart Integration 5 IDCO Paceart OB OB 3-2 Supported Values (OB 5) 3- Name MDC_IDC_SET_LEADCHNL_LV_SENSING_ ^MDC_IDC ELECTRODE_LOCATION_ ANODE_LOCATION_3 LA^MDC Sensing MDC_IDC_SET_LEADCHNL_LV_SENSING_ CATHODE_LOCATION_ ^MDC_IDC ELECTRODE_LOCATION_ LV^MDC MDC_IDC_SET_LEADCHNL_LV_SENSING_ CATHODE_LOCATION_2 MDC_IDC_SET_LEADCHNL_LV_SENSING_ CATHODE_LOCATION_ ^MDC_IDC ELECTRODE_LOCATION_ SVC^MDC ^MDC_IDC ELECTRODE_LOCATION_ Unknown^MDC MDC_IDC_SET_LEADCHNL_LV_SENSING_ ANODE_ELECTRODE_ MDC_IDC_SET_LEADCHNL_LV_SENSING_ ANODE_ELECTRODE_2 MDC_IDC_SET_LEADCHNL_LV_SENSING_ 75456^MDC_IDC ELECTRODE_NAME_Tip^MDC ^MDC_IDC ELECTRODE_NAME_ Ring^MDC ^MDC_IDC ELECTRODE_NAME_ Ring^MDC Bradycardia Left Ventricle Sensing ANODE_ELECTRODE_ ^MDC_IDC ELECTRODE_NAME_ MDC_IDC_SET_LEADCHNL_LV_SENSING_ Ring2^MDC CATHODE_ELECTRODE_ ^MDC_IDC ELECTRODE_NAME_ MDC_IDC_SET_LEADCHNL_LV_SENSING_ CATHODE_ELECTRODE_2 MDC_IDC_SET_LEADCHNL_LV_SENSING_ CATHODE_ELECTRODE_3 Ring3^MDC ^MDC_IDC ELECTRODE_NAME_ Ring4^MDC ^MDC_IDC ELECTRODE_NAME_Coil^MDC ^MDC_IDC ELECTRODE_NAME_ SubQPatch^MDC ^MDC_IDC ELECTRODE_NAME_Can^MDC ^MDC_IDC ELECTRODE_NAME_ Unknown^MDC MDC_IDC_SET_LEADCHNL_RA_PACING_ AMPLITUDE Bradycardia Right Atrium Pacing Amplitude MDC_IDC_SET_LEADCHNL_RA_PACING_ PULSEWIDTH Bradycardia Right Atrium Pacing Pulse Width 7302 MDC_IDC_SET_LEADCHNL_RA_PACING_ POLARITY ^MDC_IDC POLARITY_UNI^MDC ^MDC_IDC POLARITY_BI^MDC Bradycardia Right Atrium Pacing Polarity
54 52 Connectivity Guide Paceart Integration IDCO Paceart OB OB 3-2 Supported Values (OB 5) 3- Name MDC_IDC_SET_LEADCHNL_RA_PACING_ CAPTURE_MODE ^MDC_IDC PACING_CAPTURE_MODE_ AdaptiveCapture^MDC ^MDC_IDC PACING_CAPTURE_MODE_ FixedPacing^MDC Bradycardia Right Atrium Pacing 75469^MDC_IDC PACING_CAPTURE_MODE_ Adaptation Mode MonitorCapture^MDC MDC_IDC_SET_LEADCHNL_RA_PACING_ ANODE_LOCATION_ ^MDC_IDC ELECTRODE_LOCATION_ RA^MDC MDC_IDC_SET_LEADCHNL_RA_PACING_ ^MDC_IDC ELECTRODE_LOCATION_ ANODE_LOCATION_2 RV^MDC MDC_IDC_SET_LEADCHNL_RA_PACING_ ^MDC_IDC ELECTRODE_LOCATION_ ANODE_LOCATION_3 LA^MDC Bradycardia Right Atrium Pacing MDC_IDC_SET_LEADCHNL_RA_PACING_ CATHODE_LOCATION_ ^MDC_IDC ELECTRODE_LOCATION_ LV^MDC MDC_IDC_SET_LEADCHNL_RA_PACING_ CATHODE_LOCATION_ ^MDC_IDC ELECTRODE_LOCATION_ SVC^MDC MDC_IDC_SET_LEADCHNL_RA_PACING_ CATHODE_LOCATION_ ^MDC_IDC ELECTRODE_LOCATION_ Unknown^MDC MDC_IDC_SET_LEADCHNL_RA_PACING_ ANODE_ELECTRODE_ MDC_IDC_SET_LEADCHNL_RA_PACING_ ANODE_ELECTRODE_ ^MDC_IDC ELECTRODE_NAME_Tip^MDC ^MDC_IDC ELECTRODE_NAME_ Ring^MDC ^MDC_IDC ELECTRODE_NAME_ Bradycardia Right Atrium Pacing MDC_IDC_SET_LEADCHNL_RA_PACING_ Ring^MDC ANODE_ELECTRODE_ ^MDC_IDC ELECTRODE_NAME_ MDC_IDC_SET_LEADCHNL_RA_PACING_ Ring2^MDC CATHODE_ELECTRODE_ ^MDC_IDC ELECTRODE_NAME_ MDC_IDC_SET_LEADCHNL_RA_PACING_ Ring3^MDC CATHODE_ELECTRODE_ ^MDC_IDC ELECTRODE_NAME_ MDC_IDC_SET_LEADCHNL_RA_PACING_ CATHODE_ELECTRODE_3 Ring4^MDC ^MDC_IDC ELECTRODE_NAME_Coil^MDC ^MDC_IDC ELECTRODE_NAME_ SubQPatch^MDC ^MDC_IDC ELECTRODE_NAME_Can^MDC ^MDC_IDC ELECTRODE_NAME_ Unknown^MDC MDC_IDC_SET_LEADCHNL_RV_PACING_ AMPLITUDE Bradycardia Right Ventricle Pacing Amplitude
55 Connectivity Guide Paceart Integration 53 IDCO Paceart OB OB 3-2 Supported Values (OB 5) 3- Name MDC_IDC_SET_LEADCHNL_RV_PACING_ PULSEWIDTH Bradycardia Right Ventricle Pacing Pulse Width 7303 MDC_IDC_SET_LEADCHNL_RV_PACING_ POLARITY ^MDC_IDC POLARITY_UNI^MDC ^MDC_IDC POLARITY_BI^MDC Bradycardia Right Ventricle Pacing Polarity MDC_IDC_SET_LEADCHNL_RV_PACING_ CAPTURE_MODE ^MDC_IDC PACING_CAPTURE_MODE_ AdaptiveCapture^MDC ^MDC_IDC PACING_CAPTURE_MODE_ FixedPacing^MDC Bradycardia Right Ventricle Pacing 75469^MDC_IDC PACING_CAPTURE_MODE_ Adaptation Mode MonitorCapture^MDC MDC_IDC_SET_LEADCHNL_RV_PACING_ ANODE_LOCATION_ ^MDC_IDC ELECTRODE_LOCATION_ RA^MDC MDC_IDC_SET_LEADCHNL_RV_PACING_ ^MDC_IDC ELECTRODE_LOCATION_ ANODE_LOCATION_2 RV^MDC MDC_IDC_SET_LEADCHNL_RV_PACING_ ^MDC_IDC ELECTRODE_LOCATION_ ANODE_LOCATION_3 LA^MDC Bradycardia Right Ventricle Pacing MDC_IDC_SET_LEADCHNL_RV_PACING_ CATHODE_LOCATION_ ^MDC_IDC ELECTRODE_LOCATION_ LV^MDC MDC_IDC_SET_LEADCHNL_RV_PACING_ CATHODE_LOCATION_ ^MDC_IDC ELECTRODE_LOCATION_ SVC^MDC MDC_IDC_SET_LEADCHNL_RV_PACING_ CATHODE_LOCATION_ ^MDC_IDC ELECTRODE_LOCATION_ Unknown^MDC MDC_IDC_SET_LEADCHNL_RV_PACING_ ANODE_ELECTRODE_ MDC_IDC_SET_LEADCHNL_RV_PACING_ ANODE_ELECTRODE_ ^MDC_IDC ELECTRODE_NAME_Tip^MDC ^MDC_IDC ELECTRODE_NAME_ Ring^MDC ^MDC_IDC ELECTRODE_NAME_ Bradycardia Right Ventricle Pacing MDC_IDC_SET_LEADCHNL_RV_PACING_ Ring^MDC ANODE_ELECTRODE_ ^MDC_IDC ELECTRODE_NAME_ MDC_IDC_SET_LEADCHNL_RV_PACING_ Ring2^MDC CATHODE_ELECTRODE_ ^MDC_IDC ELECTRODE_NAME_ MDC_IDC_SET_LEADCHNL_RV_PACING_ Ring3^MDC CATHODE_ELECTRODE_ ^MDC_IDC ELECTRODE_NAME_ MDC_IDC_SET_LEADCHNL_RV_PACING_ CATHODE_ELECTRODE_3 Ring4^MDC ^MDC_IDC ELECTRODE_NAME_Coil^MDC
56 54 Connectivity Guide Paceart Integration IDCO Paceart OB OB 3-2 Supported Values (OB 5) 3- Name ^MDC_IDC ELECTRODE_NAME_ SubQPatch^MDC ^MDC_IDC ELECTRODE_NAME_Can^MDC ^MDC_IDC ELECTRODE_NAME_ Unknown^MDC MDC_IDC_SET_LEADCHNL_LV_PACING_ AMPLITUDE Bradycardia Left Ventricle Pacing Amplitude MDC_IDC_SET_LEADCHNL_LV_PACING_ PULSEWIDTH Bradycardia Left Ventricle Pacing Pulse Width 7305 MDC_IDC_SET_LEADCHNL_LV_PACING_ POLARITY ^MDC_IDC POLARITY_UNI^MDC ^MDC_IDC POLARITY_BI^MDC Bradycardia Left Ventricle Pacing Polarity MDC_IDC_SET_LEADCHNL_LV_PACING_ CAPTURE_MODE ^MDC_IDC PACING_CAPTURE_MODE_ AdaptiveCapture^MDC ^MDC_IDC PACING_CAPTURE_MODE_ FixedPacing^MDC Bradycardia Left Ventricle Pacing Adaptation Mode 75469^MDC_IDC PACING_CAPTURE_MODE_ MonitorCapture^MDC MDC_IDC_SET_LEADCHNL_LV_PACING_ ANODE_LOCATION_ ^MDC_IDC ELECTRODE_LOCATION_ RA^MDC MDC_IDC_SET_LEADCHNL_LV_PACING_ ^MDC_IDC ELECTRODE_LOCATION_ ANODE_LOCATION_2 RV^MDC MDC_IDC_SET_LEADCHNL_LV_PACING_ ^MDC_IDC ELECTRODE_LOCATION_ ANODE_LOCATION_3 LA^MDC Bradycardia Left Ventricle Pacing MDC_IDC_SET_LEADCHNL_LV_PACING_ ANODE_ELECTRODE_ ^MDC_IDC ELECTRODE_LOCATION_ LV^MDC MDC_IDC_SET_LEADCHNL_LV_PACING_ ANODE_ELECTRODE_ ^MDC_IDC ELECTRODE_LOCATION_ SVC^MDC MDC_IDC_SET_LEADCHNL_LV_PACING_ ANODE_ELECTRODE_ ^MDC_IDC ELECTRODE_LOCATION_ Unknown^MDC MDC_IDC_SET_LEADCHNL_LV_PACING_ ANODE_ELECTRODE_3 MDC_IDC_SET_LEADCHNL_LV_PACING_ CATHODE_LOCATION_ ^MDC_IDC ELECTRODE_NAME_Tip^MDC ^MDC_IDC ELECTRODE_NAME_ Ring^MDC Bradycardia Left Ventricle Pacing
57 Connectivity Guide Paceart Integration 55 IDCO Paceart OB OB 3-2 Supported Values (OB 5) 3- Name MDC_IDC_SET_LEADCHNL_LV_PACING_ ^MDC_IDC ELECTRODE_NAME_ CATHODE_LOCATION_3 Ring^MDC MDC_IDC_SET_LEADCHNL_LV_PACING_ CATHODE_ELECTRODE_ ^MDC_IDC ELECTRODE_NAME_ Ring2^MDC MDC_IDC_SET_LEADCHNL_LV_PACING_ CATHODE_ELECTRODE_2 MDC_IDC_SET_LEADCHNL_LV_PACING_ CATHODE_ELECTRODE_ ^MDC_IDC ELECTRODE_NAME_ Ring3^MDC ^MDC_IDC ELECTRODE_NAME_ Ring4^MDC ^MDC_IDC ELECTRODE_NAME_Coil^MDC ^MDC_IDC ELECTRODE_NAME_ SubQPatch^MDC ^MDC_IDC ELECTRODE_NAME_Can^MDC ^MDC_IDC ELECTRODE_NAME_ Unknown^MDC MDC_IDC_SET_BRADY_MODE ^MDC_IDC BRADY_MODE_AAI^MDC ^MDC_IDC BRADY_MODE_AAIR^MDC Bradycardia ^MDC_IDC BRADY_MODE_AAT^MDC Pacing Mode ^MDC_IDC BRADY_MODE_AATR^MDC ^MDC_IDC BRADY_MODE_AOO^MDC ^MDC_IDC BRADY_MODE_AOOR^MDC ^MDC_IDC BRADY_MODE_DAD^MDC ^MDC_IDC BRADY_MODE_DDD^MDC 75476^MDC_IDC BRADY_MODE_DDDR^MDC ^MDC_IDC BRADY_MODE_DDI^MDC ^MDC_IDC BRADY_MODE_DDIR^MDC ^MDC_IDC BRADY_MODE_DOO^MDC ^MDC_IDC BRADY_MODE_DOOR^MDC ^MDC_IDC BRADY_MODE_DVI^MDC ^MDC_IDC BRADY_MODE_DVIR^MDC ^MDC_IDC BRADY_MODE_VAT^MDC ^MDC_IDC BRADY_MODE_VDD^MDC ^MDC_IDC BRADY_MODE_VDDR^MDC 75477^MDC_IDC BRADY_MODE_VOO^MDC ^MDC_IDC BRADY_MODE_VOOR^MDC ^MDC_IDC BRADY_MODE_VVI^MDC ^MDC_IDC BRADY_MODE_VVIR^MDC ^MDC_IDC BRADY_MODE_VVT^MDC ^MDC_IDC BRADY_MODE_OOO^MDC ^MDC_IDC BRADY_MODE_OOOR^MDC
58 56 Connectivity Guide Paceart Integration IDCO Paceart OB OB 3-2 Supported Values (OB 5) 3- Name ^MDC_IDC BRADY_MODE_VDI^MDC ^MDC_IDC BRADY_MODE_VDIR^MDC ^MDC_IDC BRADY_MODE_ODO^MDC 75478^MDC_IDC BRADY_MODE_VVTR^MDC ^MDC_IDC BRADY_MODE_DDTR^MDC ^MDC_IDC BRADY_MODE_OVO^MDC ^MDC_IDC BRADY_MODE_DVTR^MDC ^MDC_IDC BRADY_MODE_DDT^MDC ^MDC_IDC BRADY_MODE_VDTR^MDC ^MDC_IDC BRADY_MODE_VDT^MDC ^MDC_IDC BRADY_MODE_ADIR^MDC ^MDC_IDC BRADY_MODE_ADI^MDC ^MDC_IDC BRADY_MODE_Unknown MDC_IDC_SET_BRADY_LOWRATE Bradycardia Lower Rate MDC_IDC_SET_BRADY_HYRATE Bradycardia Hysteresis Rate MDC_IDC_SET_BRADY_NIGHT_RATE Bradycardia Sleep Rate 7336 MDC_IDC_SET_BRADY_MA_TRACKING_RATE Bradycardia Maximum Tracking Rate MDC_IDC_SET_BRADY_MA_SENSOR_RATE Bradycardia Maximum Sensor Rate MDC_IDC_SET_BRADY_SAV_DELAY Bradycardia AV Delay Sensed MDC_IDC_SET_BRADY_SAV_DELAY_HIGH Bradycardia AV Delay Sensed
59 Connectivity Guide Paceart Integration 57 IDCO Paceart OB OB 3-2 Supported Values (OB 5) 3- Name MDC_IDC_SET_BRADY_SAV_DELAY_LOW Bradycardia AV Delay Adaptive Sensed Minimum MDC_IDC_SET_BRADY_PAV_DELAY Bradycardia AV Delay Paced MDC_IDC_SET_BRADY_PAV_DELAY_HIGH Bradycardia AV Delay Paced MDC_IDC_SET_BRADY_PAV_DELAY_LOW Bradycardia AV Delay Adaptive Paced Minimum MDC_IDC_SET_BRADY_AT_MODE_SWITCH_ MODE ^MDC_IDC BRADY_MODE_AAI^MDC ^MDC_IDC BRADY_MODE_AAIR^MDC Bradycardia ^MDC_IDC BRADY_MODE_AAT^MDC Automatic Mode ^MDC_IDC BRADY_MODE_AATR^MDC ^MDC_IDC BRADY_MODE_AOO^MDC Switch Pacing Mode ^MDC_IDC BRADY_MODE_AOOR^MDC ^MDC_IDC BRADY_MODE_DAD^MDC ^MDC_IDC BRADY_MODE_DDD^MDC 75476^MDC_IDC BRADY_MODE_DDDR^MDC ^MDC_IDC BRADY_MODE_DDI^MDC ^MDC_IDC BRADY_MODE_DDIR^MDC ^MDC_IDC BRADY_MODE_DOO^MDC ^MDC_IDC BRADY_MODE_DOOR^MDC ^MDC_IDC BRADY_MODE_DVI^MDC ^MDC_IDC BRADY_MODE_DVIR^MDC ^MDC_IDC BRADY_MODE_VAT^MDC ^MDC_IDC BRADY_MODE_VDD^MDC ^MDC_IDC BRADY_MODE_VDDR^MDC 75477^MDC_IDC BRADY_MODE_VOO^MDC ^MDC_IDC BRADY_MODE_VOOR^MDC ^MDC_IDC BRADY_MODE_VVI^MDC ^MDC_IDC BRADY_MODE_VVIR^MDC ^MDC_IDC BRADY_MODE_VVT^MDC
60 58 Connectivity Guide Paceart Integration IDCO Paceart OB OB 3-2 Supported Values (OB 5) 3- Name ^MDC_IDC BRADY_MODE_OOO^MDC ^MDC_IDC BRADY_MODE_OOOR^MDC ^MDC_IDC BRADY_MODE_VDI^MDC ^MDC_IDC BRADY_MODE_VDIR^MDC ^MDC_IDC BRADY_MODE_ODO^MDC 75478^MDC_IDC BRADY_MODE_VVTR^MDC ^MDC_IDC BRADY_MODE_DDTR^MDC ^MDC_IDC BRADY_MODE_OVO^MDC ^MDC_IDC BRADY_MODE_DVTR^MDC ^MDC_IDC BRADY_MODE_DDT^MDC ^MDC_IDC BRADY_MODE_VDTR^MDC ^MDC_IDC BRADY_MODE_VDT^MDC ^MDC_IDC BRADY_MODE_ADIR^MDC ^MDC_IDC BRADY_MODE_ADI^MDC ^MDC_IDC BRADY_MODE_Unknown MDC_IDC_SET_BRADY_AT_MODE_SWITCH_ RATE Bradycardia Automatic Mode Switch Pacing Rate MDC_IDC_SET_ZONE_TYPE ^MDC_IDC ZONE_TYPE_Zone_VF^MDC ^MDC_IDC ZONE_TYPE_Zone_VT^MDC ^MDC_IDC ZONE_TYPE_Zone_ATAF^MDC Zone 7372 MDC_IDC_SET_ZONE_VENDOR_TYPE 77388^MDC_IDC ZONE_VENDOR_TYPE_ J-Zone_VT^MDC 77389^MDC_IDC ZONE_VENDOR_TYPE_ J-Zone_VT2^MDC Zone MDC_IDC_SET_ZONE_ATUS ^MDC_IDC ZONE_ATUS_Active^MDC 75500^MDC_IDC ZONE_ATUS_Inactive^MDC Zone Detection Status MDC_IDC_SET_ZONE_DETECTION_INTERVAL Zone Detection Interval MDC_IDC_SET_ZONE_DETECTION_BEATS_ NUMERATOR
61 Connectivity Guide Paceart Integration 59 IDCO Paceart OB OB 3-2 Supported Values (OB 5) 3- Name Zone Shared Detection Duration Beat Ratio Numerator MDC_IDC_SET_ZONE_DETECTION_BEATS_ DENOMINATOR Zone Shared Detection Duration Beat Ratio Denominator MDC_IDC_SET_ZONE_SHOCK_ENERGY_ MDC_IDC_SET_ZONE_SHOCK_ENERGY_ MDC_IDC_SET_ZONE_SHOCK_ENERGY_ MDC_IDC_SET_ZONE_SHOCK_ENERGY_4 Energy MDC_IDC_SET_ZONE_SHOCK_ENERGY_ MDC_IDC_SET_ZONE_SHOCK_ENERGY_ MDC_IDC_SET_ZONE_SHOCK_ENERGY_ MDC_IDC_SET_ZONE_SHOCK_ENERGY_ MDC_IDC_SET_ZONE_SHOCK_ENERGY_ MDC_IDC_SET_ZONE_SHOCK_ENERGY_ MDC_IDC_SET_ZONE_TYPE_ATP_ MDC_IDC_SET_ZONE_TYPE_ATP_ ^MDC_IDC ATP_TYPE_Burst^MDC ^MDC_IDC ATP_TYPE_Ramp^MDC ATP MDC_IDC_SET_ZONE_TYPE_ATP_ ^MDC_IDC ATP_TYPE_BurstScan^MDC MDC_IDC_SET_ZONE_TYPE_ATP_ ^MDC_IDC ATP_TYPE_RampScan^MDC 7320 MDC_IDC_SET_ZONE_TYPE_ATP_ ^MDC_IDC ATP_TYPE_Unknown^MDC MDC_IDC_SET_ZONE_TYPE_ATP_ MDC_IDC_SET_ZONE_TYPE_ATP_ MDC_IDC_SET_ZONE_TYPE_ATP_ MDC_IDC_SET_ZONE_TYPE_ATP_ MDC_IDC_SET_ZONE_TYPE_ATP_ MDC_IDC_SET_ZONE_NUM_ATP_SEQS_ MDC_IDC_SET_ZONE_NUM_ATP_SEQS_2 ATP MDC_IDC_SET_ZONE_NUM_ATP_SEQS_ MDC_IDC_SET_ZONE_NUM_ATP_SEQS_4 Sequence ID MDC_IDC_SET_ZONE_NUM_ATP_SEQS_5
62 60 Connectivity Guide Paceart Integration IDCO Paceart OB OB 3-2 Supported Values (OB 5) 3- Name MDC_IDC_SET_ZONE_NUM_ATP_SEQS_ MDC_IDC_SET_ZONE_NUM_ATP_SEQS_ MDC_IDC_SET_ZONE_NUM_ATP_SEQS_ MDC_IDC_SET_ZONE_NUM_ATP_SEQS_ MDC_IDC_SET_ZONE_NUM_ATP_SEQS_ MDC_IDC_SET_LEADHVCHNL_SHOCK_ VECTOR_ANODE_LOCATION_ ^MDC_IDC ELECTRODE_LOCATION_ RA^MDC MDC_IDC_SET_LEADHVCHNL_SHOCK_ ^MDC_IDC ELECTRODE_LOCATION_ VECTOR_ANODE_LOCATION_2 RV^MDC MDC_IDC_SET_LEADHVCHNL_SHOCK_ ^MDC_IDC ELECTRODE_LOCATION_ VECTOR_ANODE_LOCATION_3 LA^MDC MDC_IDC_SET_LEADHVCHNL_SHOCK_ VECTOR_CATHODE_LOCATION_ ^MDC_IDC ELECTRODE_LOCATION_ LV^MDC MDC_IDC_SET_LEADHVCHNL_SHOCK_ VECTOR_CATHODE_LOCATION_ ^MDC_IDC ELECTRODE_LOCATION_ SVC^MDC MDC_IDC_SET_LEADHVCHNL_SHOCK_ VECTOR_CATHODE_LOCATION_ ^MDC_IDC ELECTRODE_LOCATION_ Unknown^MDC MDC_IDC_SET_LEADHVCHNL_SHOCK_ VECTOR_ANODE_ELECTRODE_ MDC_IDC_SET_LEADHVCHNL_SHOCK_ VECTOR_ANODE_ELECTRODE_ ^MDC_IDC ELECTRODE_NAME_Tip^MDC ^MDC_IDC ELECTRODE_NAME_ Ring^MDC ^MDC_IDC ELECTRODE_NAME_ MDC_IDC_SET_LEADHVCHNL_SHOCK_ Ring^MDC VECTOR_ANODE_ELECTRODE_ ^MDC_IDC ELECTRODE_NAME_ MDC_IDC_SET_LEADHVCHNL_SHOCK_ Ring2^MDC VECTOR_CATHODE_ELECTRODE_ ^MDC_IDC ELECTRODE_NAME_ MDC_IDC_SET_LEADHVCHNL_SHOCK_ Ring3^MDC VECTOR_CATHODE_ELECTRODE_ ^MDC_IDC ELECTRODE_NAME_ MDC_IDC_SET_LEADHVCHNL_SHOCK_ VECTOR_CATHODE_ELECTRODE_3 Ring4^MDC ^MDC_IDC ELECTRODE_NAME_Coil^MDC ^MDC_IDC ELECTRODE_NAME_ SubQPatch^MDC ^MDC_IDC ELECTRODE_NAME_Can^MDC ^MDC_IDC ELECTRODE_NAME_ Unknown^MDC
63 Connectivity Guide Paceart Integration 6 Table : MDC_IDC_AT IDCO Paceart OB OB 3-2 Supported Values (OB 5) Name MDC_IDC_AT_HEART_RATE_DTM_ART Measured Physiological Measurements Since Last Session Start Date MDC_IDC_AT_HEART_RATE_DTM_END Measured Physiological Measurements Since Last Session End Date MDC_IDC_AT_HEART_RATE_ATRIAL Integer Measured Physiological Measurements Since Last Session Right Atrium Measured Heart Rate MDC_IDC_AT_HEART_RATE_ATRIAL_MA Integer Measured Physiological Measurements Since Last Session Right Atrium Maximum Heart Rate MDC_IDC_AT_HEART_RATE_ATRIAL_MIN Integer Measured Physiological Measurements Since Last Session Right Atrium Minimum Heart Rate MDC_IDC_AT_HEART_RATE_ATRIAL_MEAN Integer Measured Physiological Measurements Since Last Session Right Atrium Mean Heart Rate MDC_IDC_AT_HEART_RATE_VENTRICULAR Integer Measured Physiological Measurements
64 62 Connectivity Guide Paceart Integration IDCO Paceart OB OB 3-2 Supported Values (OB 5) Name 3- Since Last Session Right Ventricle Measured Heart Rate MDC_IDC_AT_HEART_RATE_VENTRICULAR_MA Integer Measured Physiological Measurements Since Last Session Right Ventricle Maximum Heart Rate MDC_IDC_AT_HEART_RATE_VENTRICULAR_MIN Integer Measured Physiological Measurements Since Last Session Right Ventricle Minimum Heart Rate MDC_IDC_AT_HEART_RATE_VENTRICULAR_MEAN Integer Measured Physiological Measurements Since Last Session Right Ventricle Mean Heart Rate MDC_IDC_AT_BRADY_DTM_ART Measured Bradycardia Measurements Since Last Session Start Date MDC_IDC_AT_BRADY_DTM_END Measured Bradycardia Measurements Since Last Session End Date MDC_IDC_AT_BRADY_RA_PERCENT_PACED Measured Bradycardia Measurements Since Last Session Right Atrium Percent Paced MDC_IDC_AT_BRADY_RV_PERCENT_PACED Measured
65 Connectivity Guide Paceart Integration 63 IDCO Paceart OB OB 3-2 Supported Values (OB 5) Name 3- Bradycardia Measurements Since Last Session Right Ventricle Percent Paced MDC_IDC_AT_BRADY_AP_VP_PERCENT Measured Bradycardia Measurements Since Last Session AP VP Percent MDC_IDC_AT_BRADY_AS_VP_PERCENT Measured Bradycardia Measurements Since Last Session AS VP Percent MDC_IDC_AT_BRADY_AP_VS_PERCENT Measured Bradycardia Measurements Since Last Session AP VS Percent MDC_IDC_AT_BRADY_AS_VS_PERCENT Measured Bradycardia Measurements Since Last Session AS VS Percent MDC_IDC_AT_AT_DTM_ART Measured Atrial Counters Since Last Session Start Date MDC_IDC_AT_AT_DTM_END Measured Atrial Counters Since Last Session End Date MDC_IDC_AT_AT_MODE_SW_MA_DURATION Measured Atrial Counters Since Last Session Mode Switch Maximum Duration
66 64 Connectivity Guide Paceart Integration IDCO Paceart OB OB 3-2 Supported Values (OB 5) Name MDC_IDC_AT_AT_BURDEN_PERCENT Measured Atrial Counters Since Last Session AT AF Burden MDC_IDC_AT_AT_MODE_SW_PERCENT_TIME Integer Measured Atrial Counters Since Last Session Mode Switch Burden MDC_IDC_AT_AT_MODE_SW_PERCENT_TIME_PER_DAY Integer Measured Atrial Counters Since Last Session Mode Switch Average Daily Burden MDC_IDC_AT_AT_MODE_SW_COUNT Integer Measured Atrial Counters Since Last Session Mode Switch Count MDC_IDC_AT_AT_MODE_SW_COUNT_PER_DAY Integer Measured Atrial Counters Since Last Session Mode Switch Average Daily Count MDC_IDC_AT_CRT_DTM_ART Measured Heart Failure Counters Since Last Session Start Date MDC_IDC_AT_CRT_DTM_END Measured Heart Failure Counters Since Last Session End Date MDC_IDC_AT_CRT_LV_PERCENT_PACED Measured Bradycardia Measurements Since Last Session
67 Connectivity Guide Paceart Integration 65 IDCO Paceart OB OB 3-2 Supported Values (OB 5) Name 3- Left Ventricle Percent Paced MDC_IDC_AT_CRT_PERCENT_PACED Measured Heart Failure Counters Since Last Session CRT Percent Paced MDC_IDC_AT_TACHYTHERAPY_SHOCKS_DELIVERED_ Integer RECENT Measured Counters Since Last Counter Reset Right Ventricle s Delivered MDC_IDC_AT_TACHYTHERAPY_SHOCKS_DELIVERED_ Integer TOTAL Measured Counters Lifetime Right Ventricle s Delivered MDC_IDC_AT_TACHYTHERAPY_SHOCKS_ABORTED_ Integer RECENT Measured Counters Since Last Counter Reset Right Ventricle s Aborted MDC_IDC_AT_TACHYTHERAPY_SHOCKS_ABORTED_TOTAL Integer Measured Counters Lifetime Right Ventricle s Aborted MDC_IDC_AT_TACHYTHERAPY_ATP_DELIVERED_RECENT Integer Measured Counters Since Last Counter Reset Right Ventricle ATP Delivered MDC_IDC_AT_TACHYTHERAPY_ATP_DELIVERED_TOTAL Integer Measured
68 66 Connectivity Guide Paceart Integration IDCO Paceart OB OB 3-2 Supported Values (OB 5) Name 3- Counters Lifetime Right Ventricle ATP Delivered MDC_IDC_AT_TACHYTHERAPY_TOTAL_DTM_ART Measured Counters Lifetime Start Date MDC_IDC_AT_TACHYTHERAPY_TOTAL_DTM_END Measured Counters Lifetime End Date MDC_IDC_AT_TACHYTHERAPY_RECENT_DTM_ART Measured Counters Since Last Counter Reset Start Date MDC_IDC_AT_TACHYTHERAPY_RECENT_DTM_END Measured Counters Since Last Counter Reset End Date when ^MDC_IDC_AT_EPISODE_VENDOR_TYPE^MDC has OB-5 value of 77324^J-Epis_VT^MDC MDC_IDC_AT_EPISODE_RECENT_COUNT Measured Detection Counters Since Last Counter Reset VT Monitor Episode Count or Measured Detection Counters Since Last Counter Reset VT Episode Count when ^MDC_IDC_AT_EPISODE_VENDOR_TYPE^MDC has OB-5 value of 77324^J-Epis_VT2^MDC MDC_IDC_AT_EPISODE_RECENT_COUNT Measured Detection Counters
69 Connectivity Guide Paceart Integration 67 IDCO Paceart OB OB 3-2 Supported Values (OB 5) Name 3- Since Last Counter Reset VT2 Monitor Episode Count or Measured Detection Counters Since Last Counter Reset VT2 Episode Count when ^MDC_IDC_AT_EPISODE_TYPE^MDC has OB-5 value of 75488^MDC_IDC EPISODE_TYPE_Epis_VF^MDC MDC_IDC_AT_EPISODE_RECENT_COUNT Measured Detection Counters Since Last Counter Reset VF VT Episode Count when ^MDC_IDC_AT_EPISODE_TYPE^MDC has OB-5 value of ^MDC_IDC EPISODE_TYPE_Epis_VT^MDC MDC_IDC_AT_EPISODE_RECENT_COUNT Measured Detection Counters Since Last Counter Reset VT Episode Count when ^MDC_IDC_AT_EPISODE_TYPE^MDC has OB-5 value of ^MDC_IDC EPISODE_TYPE_Epis_ATAF^MDC MDC_IDC_AT_EPISODE_RECENT_COUNT Measured Detection Counters Since Last Counter Reset AF AT Episode Count when ^MDC_IDC_AT_EPISODE_TYPE^MDC has OB-5 value of ^MDC_IDC EPISODE_TYPE_Epis_SVT^MDC MDC_IDC_AT_EPISODE_RECENT_COUNT Measured Detection Counters Since Last Counter Reset SVT Episode Count when ^MDC_IDC_AT_EPISODE_TYPE^MDC has OB-5 value of ^MDC_IDC EPISODE_TYPE_Epis_Monitor^MDC MDC_IDC_AT_EPISODE_RECENT_COUNT Measured
70 68 Connectivity Guide Paceart Integration IDCO Paceart OB OB 3-2 Supported Values (OB 5) Name 3- Detection Counters Since Last Counter Reset VF VT Monitor Episode Count Measured Detection Counters Since Last Counter Reset VT Monitor Episode Count Measured Detection Counters Since Last Counter Reset AF AT Monitor Episode Count when ^MDC_IDC_AT_EPISODE_TYPE^MDC has OB-5 value of ^MDC_IDC EPISODE_TYPE_Epis_PeriodicEGM^MDC MDC_IDC_AT_EPISODE_RECENT_COUNT Measured Detection Counters Since Last Counter Reset Periodic Episode Count when ^MDC_IDC_AT_EPISODE_TYPE^MDC has OB-5 value of ^MDC_IDC EPISODE_TYPE_Epis_PatientActivated^MDC MDC_IDC_AT_EPISODE_RECENT_COUNT Measured Detection Counters Since Last Counter Reset Patient Activated Episode Count when ^MDC_IDC_AT_EPISODE_TYPE^MDC has OB-5 value of ^MDC_IDC EPISODE_TYPE_Epis_Other^MDC MDC_IDC_AT_EPISODE_RECENT_COUNT Measured Detection Counters Since Last Counter Reset Other Episode Count
71 Connectivity Guide Paceart Integration 69 IDCO Paceart OB OB 3-2 Supported Values (OB 5) Name MDC_IDC_AT_EPISODE_RECENT_COUNT_DTM Measured Detection Counters Since Last Counter Reset Start Date MDC_IDC_AT_EPISODE_RECENT_COUNT_DTM_ART Measured Detection Counters Since Last Counter Reset Start Date MDC_IDC_AT_EPISODE_RECENT_COUNT_DTM_END Measured Detection Counters Since Last Counter Reset End Date when ^MDC_IDC_AT_EPISODE_VENDOR_TYPE^MDC has OB-5 value of 77324^J-Epis_VT^MDC MDC_IDC_AT_EPISODE_TOTAL_COUNT Measured Detection Counters Lifetime VT Episode Count or Measured Detection Counters Lifetime VT Monitor Episode Count when ^MDC_IDC_AT_EPISODE_VENDOR_TYPE^MDC has OB-5 value of 77324^J-Epis_VT2^MDC MDC_IDC_AT_EPISODE_TOTAL_COUNT Measured Detection Counters Lifetime VT2 Episode Count or Measured Detection Counters Lifetime VT2 Monitor Episode Count when ^MDC_IDC_AT_EPISODE_TYPE^MDC has OB-5 value of 75488^MDC_IDC EPISODE_TYPE_Epis_VF^MDC
72 70 Connectivity Guide Paceart Integration IDCO Paceart OB OB 3-2 Supported Values (OB 5) Name MDC_IDC_AT_EPISODE_TOTAL_COUNT Measured Detection Counters Lifetime VF VT Episode Count when ^MDC_IDC_AT_EPISODE_TYPE^MDC has OB-5 value of ^MDC_IDC EPISODE_TYPE_Epis_VT^MDC MDC_IDC_AT_EPISODE_TOTAL_COUNT Measured Detection Counters Lifetime VT Episode Count when ^MDC_IDC_AT_EPISODE_TYPE^MDC has OB-5 value of ^MDC_IDC EPISODE_TYPE_Epis_ATAF^MDC MDC_IDC_AT_EPISODE_TOTAL_COUNT Measured Detection Counters Lifetime AF AT Episode Count when ^MDC_IDC_AT_EPISODE_TYPE^MDC has OB-5 value of ^MDC_IDC EPISODE_TYPE_Epis_SVT^MDC MDC_IDC_AT_EPISODE_TOTAL_COUNT Measured Detection Counters Lifetime SVT Episode Count when ^MDC_IDC_AT_EPISODE_TYPE^MDC has OB-5 value of ^MDC_IDC EPISODE_TYPE_Epis_Monitor^MDC MDC_IDC_AT_EPISODE_TOTAL_COUNT Measured Detection Counters Lifetime VF VT Monitor Episode Count, Measured Detection Counters Lifetime VT Monitor Episode Count, Measured Detection Counters Lifetime AF AT Monitor Episode Count
73 Connectivity Guide Paceart Integration 7 IDCO Paceart OB OB 3-2 Supported Values (OB 5) Name 3- when ^MDC_IDC_AT_EPISODE_TYPE^MDC has OB-5 value of ^MDC_IDC EPISODE_TYPE_Epis_PeriodicEGM^MDC MDC_IDC_AT_EPISODE_TOTAL_COUNT Measured Detection Counters Lifetime Periodic Episode Count when ^MDC_IDC_AT_EPISODE_TYPE^MDC has OB-5 value of ^MDC_IDC EPISODE_TYPE_Epis_PatientActivated^MDC MDC_IDC_AT_EPISODE_TOTAL_COUNT Measured Detection Counters Lifetime Patient Activated Episode Count when ^MDC_IDC_AT_EPISODE_TYPE^MDC has OB-5 value of ^MDC_IDC EPISODE_TYPE_Epis_Other^MDC MDC_IDC_AT_EPISODE_TOTAL_COUNT Measured Detection Counters Lifetime Other Episode Count MDC_IDC_AT_EPISODE_TOTAL_COUNT_DTM Measured Detection Counters Lifetime Start Date MDC_IDC_AT_EPISODE_TOTAL_COUNT_DTM_ART Measured Detection Counters Lifetime Start Date MDC_IDC_AT_EPISODE_TOTAL_COUNT_DTM_END Measured Detection Counters Lifetime End Date Table : MDC_IDC_EPISODE IDCO Paceart OB OB 3-2 Supported Values (OB 5) Name MDC_IDC_EPISODE_ID Episodes Integer Episode Id
74 72 Connectivity Guide Paceart Integration IDCO Paceart OB OB 3-2 Supported Values (OB 5) Name MDC_IDC_EPISODE_DTM Episodes Episode Start MDC_IDC_EPISODE_TYPE 75488^MDC_IDC EPISODE_TYPE_Epis_VF^MDC Episodes ^MDC_IDC EPISODE_TYPE_Epis_VT^MDC Episode ^MDC_IDC EPISODE_TYPE_Epis_ ATAF^MDC ^MDC_IDC EPISODE_TYPE_Epis_SVT^MDC ^MDC_IDC EPISODE_TYPE_Epis_ Monitor^MDC ^MDC_IDC EPISODE_TYPE_Epis_ PeriodicEGM^MDC ^MDC_IDC EPISODE_TYPE_Epis_ PatientActivated^MDC ^MDC_IDC EPISODE_TYPE_Epis_ Other^MDC MDC_IDC_EPISODE_VENDOR_TYPE 77324^J-Epis_VT^MDC Episodes 77325^J-Epis_VT2^MDC Episode MDC_IDC_EPISODE_THERAPY_RESULT 75537^MDC_IDC EPISODE_THERAPY_RESULT_ Episodes Successful^MDC Episode Result 75538^MDC_IDC EPISODE_THERAPY_RESULT_ Unsuccessful^MDC 75539^MDC_IDC EPISODE_THERAPY_RESULT_ Unknown^MDC MDC_IDC_EPISODE_DURATION Episodes Episode Duration Outbound Messages Paceart Schema 7.0 Paceart integrates with the HL7 protocol for outgoing messages from Paceart to external systems by mapping a Paceart parameter and parameter type to HL7 values. This section describes outbound message mapping from Paceart schema 7.0. Outbound MSH Message Segments The HL7 MSH (Message Header) segment is present in every HL7 message type and defines the message's source, purpose, destination, and certain syntax specifics like delimiters (separator characters) and character sets. Source of Data or Literal Value ^~\& OutboundSendingApplicationNamespaceID Field MSH- MSH-2 MSH-3 Component
75 Connectivity Guide Paceart Integration 73 Source of Data or Literal Value OutboundSendingApplicationUniversalID OutboundSendingApplicationUniversalID OutboundSendingFacilityNamespaceID OutboundSendingFacilityUniversalID OutboundSendingFacilityUniversalID OutboundReceivingApplicationNamespaceID OutboundReceivingApplicationUniversalID OutboundReceivingApplicationUniversalID OutboundReceivingFacilityNamespaceID OutboundReceivingFacilityUniversalID OutboundReceivingFacilityUniversalID ORU R0 OutboundProcessingID OutboundProcessingIDMode OutboundHL7Version Field MSH-3 MSH-3 MSH-4 MSH-4 MSH-4 MSH-5 MSH-5 MSH-5 MSH-6 MSH-6 MSH-6 MSH-7 MSH-9 MSH-9 MSH-0 MSH- MSH- MSH-2 Component Outbound PID Message Segments The PID (Patient Identification) segment provides important identification information about the patient and is used as the primary means of communicating the identifying and demographic information about a patient between systems. Paceart parameter Field Component Sub-Component Occurrence Session Device Model PID-3 Session Device Serial Number PID-3 Patient ID Value PID Session Device Manufacturer PID-3 4 Patient ID Description PID Patient Last Name PID-5 Patient First Name PID-5 2 Patient Middle Initial String PID-5 3 Patient Birth Date PID-7
76 74 Connectivity Guide Paceart Integration Paceart parameter Field Component Sub-Component Occurrence Patient Gender PID-8 Patient Address Line PID- Patient Address Line 2 PID- 2 Patient Address City PID- 3 Patient Address State String 0 PID- 4 Patient Address Postal Code String 0 PID- 5 Patient Address Country PID- 6 Outbound PV Message Segments The PV (Patient Visit) segment is used by registration applications to communicate information on a visit-specific basis. Paceart parameter Field Component Sub-Component Occurrence Patient Status String PV-2 Visit ID PV-9 Outbound PV2 Message Segments The PV2 (Patient Visit) segment is a continuation of visit-specific information contained in the PV segment. Paceart parameter Field Component Sub-Component Occurrence Patient Code Value String 6 PV2-7 m Outbound OBR Message Segments The OBR (Observation Request) segment transmits information about an exam, diagnostic study/observation, or assessment that is specific to an order or result. Paceart parameter Field Component Sub-Component Occurrence Key String 32 OBR-3 OBR-4 Date and Time OBR-7 Provider Code String 6 OBR-6 Provider Last Name OBR-6 2 Provider First Name OBR-6 3 Provider Middle Initial String OBR-6 4 Provider Credentials String 20 OBR-6 5
77 Connectivity Guide Paceart Integration 75 Paceart parameter Field Component Sub-Component Occurrence Parent Key OBR-26 Provider Code String 6 OBR-28 Provider Last Name OBR-28 2 Provider First Name OBR-28 3 Provider Middle Initial String OBR-28 4 Provider Credentials String 20 OBR-28 5 Outbound NTE Message Segments The NTE segment is an optional segment used after OB segments to provide notes and comments. Paceart NTE- NTE-3 Comment String NTE_Counter /PaceartML/PatientRecord/s/[]/Comment Outbound OB Messages The OB segment is primarily used to carry key clinical observation and result reporting information within report messages. Nonconforming and discriminator OB values Each OB message segment has a value to specify nonconforming values. An OB-8 value of "NC-PA" means that the data was nonconforming in Paceart. An OB-8 value of "NC-IDCO" means that the data does not conform to the IDCO profile definition for the data. The OB-8 value is also used to specify a discriminator value for numerical data. For example, a numerical message segment allows the less-than (<) and greater-than (>) symbols, but not the less-than or equal to (<=) and greater-than or equal to (>=) symbols. The following segment is for valid values of the number: Paceart parameter type OB-2 OB-3 OB-4 OB-6 OB-8 Bradycardia Automatic Mode Switch Pacing Rate 73456^MDC_IDC_ SET_BRADY_AT_ MODE_SWITCH_ RATE^MDC {beats}/min^ heartbeats per minute^mdc >, < While the following segment is for nonconforming values of the number: Paceart parameter type OB-2 OB-3 OB-4 OB-6 OB-8 Bradycardia Automatic 73456^MDC_IDC_ SET_BRADY_AT_ MODE_SWITCH_ RATE^MDC {beats}/min^ heartbeats per minute^mdc >=^NC-IDCO, <=^NC-IDCO
78 76 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 OB-8 Mode Switch Pacing Rate Enumerations For OB message segments that have a Paceart of, there are multiple OB-5 values for each possible value of the enumeration. These values are not listed in the OB message segment tables. Outbound OB Session Message Segments Paceart parameter type OB-2 OB-3 OB-4 OB-6 Session Timestamp DTM 72025^MDC_IDC_SESS_DTM^MDC 72026^MDC_IDC_SESS_TYPE^MDC Session Reprogrammed 72027^MDC_SESS_REPROGRAMMED^MDC Session Device ^MDC_IDC_PG_TYPE^MDC Session Device Manufacturer ^MDC_IDC_PG_MFG^MDC Session Device Model ^MDC_IDC_PG_MODEL^MDC Session Device Serial Number ^MDC_IDC_PG_SERIAL^MDC Outbound OB Programming Bradycardia Message Segments Paceart parameter type OB-2 OB-3 OB-4 OB-6 Bradycardia Pacing Mode ^MDC_IDC_SET_BRADY_MODE^MDC Bradycardia Lower Rate ^MDC_IDC_SET_BRADY_LOWRATE^MDC {beats}/min^ heartbeats per minute^mdc Bradycardia Maximum Tracking Rate 7336^MDC_IDC_SET_BRADY_MA_TRACKING_ RATE^MDC {beats}/min^ heartbeats per minute^mdc Bradycardia Maximum Sensor Rate 73200^MDC_IDC_SET_BRADY_MA_SENSOR_ RATE^MDC {beats}/min^ heartbeats per minute^mdc Bradycardia Hysteresis Rate ^MDC_IDC_SET_BRADY_HYRATE^MDC {beats}/min^ heartbeats per minute^mdc Bradycardia Sleep Rate 73008^MDC_IDC_SET_BRADY_NIGHT_RATE^MDC {beats}/min^ heartbeats per minute^mdc Bradycardia Pacemaker Mediated Intervention 0000^MDT_PROG_BRADY_PMT_INTERVENTION^MDT
79 Connectivity Guide Paceart Integration 77 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Bradycardia Premature Ventricular Contraction Intervention 00002^MDT_PROG_BRADY_PVC_RESPONSE^MDT Bradycardia Rate Modulation Threshold 00003^MDT_PROG_BRADY_RATEMODULATION_ THRESHOLD^MDT Bradycardia Rate Modulation Slope 00004^MDT_PROG_BRADY_RATEMODULATION_ SLOPE^MDT Bradycardia Rate Modulation Slope Exertion 00005^MDT_PROG_BRADY_RATEMODULATION_SLOPE_ EERTION^MDT Bradycardia Rate Modulation Acceleration Reaction 00006^MDT_PROG_BRADY_RATEMODULATION_ ACCELERATIONREACTION^MDT s^seconds^mdc Bradycardia Rate Modulation Deceleration Recovery 00007^MDT_PROG_BRADY_RATEMODULATION_ DECELERATIONRECOVERY^MDT m^minutes^mdc Bradycardia Rate Modulation Activities of Daily Living Rate 00008^MDT_PROG_BRADY_RATEMODULATION_ ADLRATE^MDT {beats}/min^ heartbeats per minute^mdc Bradycardia AV Delay Sensed 73265^MDC_IDC_SET_BRADY_SAV_DELAY_HIGH^MDC Bradycardia AV Delay Paced 73329^MDC_IDC_SET_BRADY_PAV_DELAY_HIGH^MDC Bradycardia AV Delay Adaptive Status 00009^MDT_PROG_BRADY_AVDELAY_ADAPTIVE_ ATUS^MDT Bradycardia AV Delay Adaptive Paced Minimum 73330^MDC_IDC_SET_BRADY_PAV_DELAY_LOW^MDC Bradycardia AV Delay Adaptive Sensed Minimum 73266^MDC_IDC_SET_BRADY_SAV_DELAY_LOW^MDC Bradycardia AV Delay Adaptive Start Rate 0002^MDT_PROG_BRADY_AVDELAY_ADAPTIVE_ ARTRATE^MDT {beats}/min^ heartbeats per minute^mdc
80 78 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Bradycardia AV Delay Adaptive Stop Rate 0003^MDT_PROG_BRADY_AVDELAY_ADAPTIVE_ OPRATE^MDT {beats}/min^ heartbeats per minute^mdc Bradycardia AV Delay Adaptive Curve Description 0000^MDT_PROG_BRADY_AVDELAY_ CURVEDESCRIPTION^MDT Bradycardia Automatic Mode Switch Status 000^MDT_PROG_BRADY_ AUTOMATICEMODESWITCH_ATUS^MDT Bradycardia Automatic Mode Switch Detection Criteria Rate 0004^MDT_PROG_BRADY_ AUTOMATICEMODESWITCH_DETECTION_CRITERIA_ RATE^MDT {beats}/min^ heartbeats per minute^mdc Bradycardia Automatic Mode Switch Detection Duration Fixed 0005^MDT_PROG_BRADY_ AUTOMATICEMODESWITCH_DETECTION_CRITERIA_ DURATION_FIED^MDT s^seconds^mdc Bradycardia Automatic Mode Switch Detection Duration Beat Ratio Numerator 0006^MDT_PROG_BRADY_ AUTOMATICEMODESWITCH_DETECTION_CRITERIA_ DURATION_BEATRATIO_NUMERATOR^MDT {beats}^heartbeats^mdc Bradycardia Automatic Mode Switch Detection Duration Beat Ratio Denominator 0007^MDT_PROG_BRADY_ AUTOMATICEMODESWITCH_DETECTION_CRITERIA_ DURATION_BEATRATIO_DENOMINATOR^MDT {beats}^heartbeats^mdc Bradycardia Automatic Mode Switch Detection Duration Beat Count 0008^MDT_PROG_BRADY_ AUTOMATICEMODESWITCH_DETECTION_CRITERIA_ DURATION_BEATCOUNT^MDT {beats}^heartbeats^mdc Bradycardia Automatic Mode Switch Pacing Rate 73456^MDC_IDC_SET_BRADY_AT_MODE_SWITCH_ RATE^MDC {beats}/min^ heartbeats per minute^mdc Bradycardia Automatic Mode Switch Pacing Mode 73392^MDC_IDC_SET_BRADY_AT_MODE_SWITCH_ MODE^MDC Bradycardia Left Ventricle Sensing Polarity ^MDC_IDC_SET_LEADCHNL_LV_SENSING_ POLARITY^MDC
81 Connectivity Guide Paceart Integration 79 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Bradycardia Left Ventricle Sensing 72973^MDC_IDC_SET_LEADCHNL_LV_SENSING_ ANODE_LOCATION_^MDC Bradycardia Left Ventricle Sensing ^MDC_IDC_SET_LEADCHNL_LV_SENSING_ ANODE_ELECTRODE_^MDC Bradycardia Left Ventricle Sensing 72974^MDC_IDC_SET_LEADCHNL_LV_SENSING_ ANODE_LOCATION_2^MDC Bradycardia Left Ventricle Sensing ^MDC_IDC_SET_LEADCHNL_LV_SENSING_ ANODE_ELECTRODE_2^MDC Bradycardia Left Ventricle Sensing 72975^MDC_IDC_SET_LEADCHNL_LV_SENSING_ ANODE_LOCATION_3^MDC Bradycardia Left Ventricle Sensing ^MDC_IDC_SET_LEADCHNL_LV_SENSING_ ANODE_ELECTRODE_3^MDC Bradycardia Left Ventricle Sensing 72984^MDC_IDC_SET_LEADCHNL_LV_SENSING_ CATHODE_LOCATION_^MDC Bradycardia Left Ventricle Sensing ^MDC_IDC_SET_LEADCHNL_LV_SENSING_ CATHODE_ELECTRODE_^MDC Bradycardia Left Ventricle Sensing ^MDC_IDC_SET_LEADCHNL_LV_SENSING_ CATHODE_LOCATION_2^MDC Bradycardia Left Ventricle Sensing ^MDC_IDC_SET_LEADCHNL_LV_SENSING_ CATHODE_ELECTRODE_2^MDC Bradycardia Left Ventricle Sensing ^MDC_IDC_SET_LEADCHNL_LV_SENSING_ CATHODE_LOCATION_3^MDC ^MDC_IDC_SET_LEADCHNL_LV_SENSING_ CATHODE_ELECTRODE_3^MDC
82 80 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Bradycardia Left Ventricle Sensing Bradycardia Left Ventricle Sensing Blanking Previous Event Chamber 0043^MDT_PROG_BRADY_REFRACTORYPERIOD_ PREVIOUSEVENTCHAMBER_LV^MDT [m] Bradycardia Left Ventricle Sensing Refractory Period Interval 0044^MDT_PROG_BRADY_REFRACTORYPERIOD_ INTERVAL_LV^MDT [m] Bradycardia Left Ventricle Sensing Blanking Previous Event Chamber 005^MDT_PROG_BRADY_BLANKINGPERIOD_ PREVIOUSEVENTCHAMBER_LV^MDT [m] Bradycardia Left Ventricle Sensing Blanking Previous Event 0052^MDT_PROG_BRADY_BLANKINGPERIOD_ EVENTTYPE_LV^MDT [m] Bradycardia Left Ventricle Sensing Blanking Interval 0053^MDT_PROG_BRADY_BLANKINGPERIOD_ INTERVAL_LV^MDT [m] Bradycardia Left Ventricle Sensing Amplitude ^MDC_IDC_SET_LEADCHNL_LV_SENSING_ SENSITIVITY^MDC mv^millivolts^mdc Bradycardia Left Ventricle Sensing Amplitude Adaptation Mode ^MDC_IDC_SET_LEADCHNL_LV_SENSING_ ADAPTATION_MODE^MDC Bradycardia Right Atrium Sensing Polarity ^MDC_IDC_SET_LEADCHNL_RA_SENSING_ POLARITY^MDC Bradycardia Right Atrium Sensing ^MDC_IDC_SET_LEADCHNL_RA_SENSING_ ANODE_LOCATION_^MDC Bradycardia Right Atrium Sensing ^MDC_IDC_SET_LEADCHNL_RA_SENSING_ ANODE_ELECTRODE_^MDC Bradycardia Right Atrium ^MDC_IDC_SET_LEADCHNL_RA_SENSING_ ANODE_LOCATION_2^MDC
83 Connectivity Guide Paceart Integration 8 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Sensing Bradycardia Right Atrium Sensing ^MDC_IDC_SET_LEADCHNL_RA_SENSING_ ANODE_ELECTRODE_2^MDC Bradycardia Right Atrium Sensing ^MDC_IDC_SET_LEADCHNL_RA_SENSING_ ANODE_LOCATION_3^MDC Bradycardia Right Atrium Sensing 72973^MDC_IDC_SET_LEADCHNL_RA_SENSING_ ANODE_ELECTRODE_3^MDC Bradycardia Right Atrium Sensing ^MDC_IDC_SET_LEADCHNL_RA_SENSING_ CATHODE_LOCATION_^MDC Bradycardia Right Atrium Sensing ^MDC_IDC_SET_LEADCHNL_RA_SENSING_ CATHODE_ELECTRODE_^MDC Bradycardia Right Atrium Sensing ^MDC_IDC_SET_LEADCHNL_RA_SENSING_ CATHODE_LOCATION_2^MDC Bradycardia Right Atrium Sensing ^MDC_IDC_SET_LEADCHNL_RA_SENSING_ CATHODE_ELECTRODE_2^MDC Bradycardia Right Atrium Sensing ^MDC_IDC_SET_LEADCHNL_RA_SENSING_ CATHODE_LOCATION_3^MDC Bradycardia Right Atrium Sensing ^MDC_IDC_SET_LEADCHNL_RA_SENSING_ CATHODE_ELECTRODE_3^MDC Bradycardia Right Atrium Sensing Blanking Previous Event Chamber 0045^MDT_PROG_BRADY_REFRACTORYPERIOD_ PREVIOUSEVENTCHAMBER_RA^MDT [m] Bradycardia Right Atrium Sensing 0046^MDT_PROG_BRADY_REFRACTORYPERIOD_ INTERVAL_RA^MDT [m]
84 82 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Refractory Period Interval Bradycardia Right Atrium Sensing Blanking Previous Event Chamber 0054^MDT_PROG_BRADY_BLANKINGPERIOD_ PREVIOUSEVENTCHAMBER_RA^MDT [m] Bradycardia Right Atrium Sensing Blanking Previous Event 0055^MDT_PROG_BRADY_BLANKINGPERIOD_ EVENTTYPE_RA^MDT [m] Bradycardia Right Atrium Sensing Blanking Interval 0056^MDT_PROG_BRADY_BLANKINGPERIOD_ INTERVAL_RA^MDT [m] Bradycardia Right Atrium Sensing Amplitude ^MDC_IDC_SET_LEADCHNL_RA_SENSING_ SENSITIVITY^MDC mv^millivolts^mdc Bradycardia Right Atrium Sensing Amplitude Adaptation Mode ^MDC_IDC_SET_LEADCHNL_RA_SENSING_ ADAPTATION_MODE^MDC Bradycardia Right Ventricle Sensing Polarity 72960^MDC_IDC_SET_LEADCHNL_RV_SENSING_ POLARITY^MDC Bradycardia Right Ventricle Sensing 72968^MDC_IDC_SET_LEADCHNL_RV_SENSING_ ANODE_LOCATION_^MDC Bradycardia Right Ventricle Sensing ^MDC_IDC_SET_LEADCHNL_RV_SENSING_ ANODE_ELECTRODE_^MDC Bradycardia Right Ventricle Sensing ^MDC_IDC_SET_LEADCHNL_RV_SENSING_ ANODE_LOCATION_2^MDC Bradycardia Right Ventricle Sensing ^MDC_IDC_SET_LEADCHNL_RV_SENSING_ ANODE_ELECTRODE_2^MDC Bradycardia Right Ventricle ^MDC_IDC_SET_LEADCHNL_RV_SENSING_ ANODE_LOCATION_3^MDC
85 Connectivity Guide Paceart Integration 83 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Sensing Bradycardia Right Ventricle Sensing ^MDC_IDC_SET_LEADCHNL_RV_SENSING_ ANODE_ELECTRODE_3^MDC Bradycardia Right Ventricle Sensing ^MDC_IDC_SET_LEADCHNL_RV_SENSING_ CATHODE_LOCATION_^MDC Bradycardia Right Ventricle Sensing ^MDC_IDC_SET_LEADCHNL_RV_SENSING_ CATHODE_ELECTRODE_^MDC Bradycardia Right Ventricle Sensing 72980^MDC_IDC_SET_LEADCHNL_RV_SENSING_ CATHODE_LOCATION_2^MDC Bradycardia Right Ventricle Sensing ^MDC_IDC_SET_LEADCHNL_RV_SENSING_ CATHODE_ELECTRODE_2^MDC Bradycardia Right Ventricle Sensing 7298^MDC_IDC_SET_LEADCHNL_RV_SENSING_ CATHODE_LOCATION_3^MDC Bradycardia Right Ventricle Sensing ^MDC_IDC_SET_LEADCHNL_RV_SENSING_ CATHODE_ELECTRODE_3^MDC Bradycardia Right Ventricle Sensing Refractory Period Previous Event Chamber 0047^MDT_PROG_BRADY_REFRACTORYPERIOD_ PREVIOUSEVENTCHAMBER_RV^MDT [m] Bradycardia Right Ventricle Sensing Refractory Period Interval 0048^MDT_PROG_BRADY_REFRACTORYPERIOD_ INTERVAL_RV^MDT [m] Bradycardia Right Ventricle Sensing Blanking Previous Event Chamber 0057^MDT_PROG_BRADY_BLANKINGPERIOD_ PREVIOUSEVENTCHAMBER_RV^MDT [m] 0058^MDT_PROG_BRADY_BLANKINGPERIOD_ EVENTTYPE_RV^MDT [m]
86 84 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Bradycardia Right Ventricle Sensing Blanking Previous Event Bradycardia Right Ventricle Sensing Blanking Interval 0059^MDT_PROG_BRADY_BLANKINGPERIOD_ INTERVAL_RV^MDT [m] Bradycardia Right Ventricle Sensing Amplitude ^MDC_IDC_SET_LEADCHNL_RV_SENSING_ SENSITIVITY^MDC mv^millivolts^mdc Bradycardia Right Ventricle Sensing Amplitude Adaptation Mode 72992^MDC_IDC_SET_LEADCHNL_RV_SENSING_ ADAPTATION_MODE^MDC Bradycardia Left Ventricle Pacing Polarity 7305^MDC_IDC_SET_LEADCHNL_LV_PACING_ POLARITY^MDC Bradycardia Left Ventricle Pacing ^MDC_IDC_SET_LEADCHNL_LV_PACING_ANODE_ LOCATION_^MDC Bradycardia Left Ventricle Pacing ^MDC_IDC_SET_LEADCHNL_LV_PACING_ANODE_ ELECTRODE_^MDC Bradycardia Left Ventricle Pacing ^MDC_IDC_SET_LEADCHNL_LV_PACING_ANODE_ LOCATION_2^MDC Bradycardia Left Ventricle Pacing ^MDC_IDC_SET_LEADCHNL_LV_PACING_ANODE_ ELECTRODE_2^MDC Bradycardia Left Ventricle Pacing ^MDC_IDC_SET_LEADCHNL_LV_PACING_ANODE_ LOCATION_3^MDC Bradycardia Left Ventricle Pacing 73029^MDC_IDC_SET_LEADCHNL_LV_PACING_ANODE_ ELECTRODE_3^MDC Bradycardia Left ^MDC_IDC_SET_LEADCHNL_LV_PACING_ CATHODE_LOCATION_^MDC
87 Connectivity Guide Paceart Integration 85 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Ventricle Pacing Bradycardia Left Ventricle Pacing 73047^MDC_IDC_SET_LEADCHNL_LV_PACING_ CATHODE_ELECTRODE_^MDC Bradycardia Left Ventricle Pacing ^MDC_IDC_SET_LEADCHNL_LV_PACING_ CATHODE_LOCATION_2^MDC Bradycardia Left Ventricle Pacing 73048^MDC_IDC_SET_LEADCHNL_LV_PACING_ CATHODE_ELECTRODE_2^MDC Bradycardia Left Ventricle Pacing ^MDC_IDC_SET_LEADCHNL_LV_PACING_ CATHODE_LOCATION_3^MDC Bradycardia Left Ventricle Pacing 73049^MDC_IDC_SET_LEADCHNL_LV_PACING_ CATHODE_ELECTRODE_3^MDC Bradycardia Left Ventricle Pacing Pulse Width 73005^MDC_IDC_SET_LEADCHNL_LV_PACING_ PULSEWIDTH^MDC Bradycardia Left Ventricle Pacing Amplitude ^MDC_IDC_SET_LEADCHNL_LV_PACING_ AMPLITUDE^MDC V^volts^MDC Bradycardia Left Ventricle Pacing Adaptation Mode ^MDC_IDC_SET_LEADCHNL_LV_PACING_ CAPTURE_MODE^MDC Bradycardia Right Atrium Pacing Polarity 7302^MDC_IDC_SET_LEADCHNL_RA_PACING_ POLARITY^MDC Bradycardia Right Atrium Pacing 73077^MDC_IDC_SET_LEADCHNL_RA_PACING_ANODE_ LOCATION_^MDC Bradycardia Right Atrium Pacing 73024^MDC_IDC_SET_LEADCHNL_RA_PACING_ANODE_ ELECTRODE_^MDC 73078^MDC_IDC_SET_LEADCHNL_RA_PACING_ANODE_ LOCATION_2^MDC
88 86 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Bradycardia Right Atrium Pacing Bradycardia Right Atrium Pacing ^MDC_IDC_SET_LEADCHNL_RA_PACING_ANODE_ ELECTRODE_2^MDC Bradycardia Right Atrium Pacing 73079^MDC_IDC_SET_LEADCHNL_RA_PACING_ANODE_ LOCATION_3^MDC Bradycardia Right Atrium Pacing ^MDC_IDC_SET_LEADCHNL_RA_PACING_ANODE_ ELECTRODE_3^MDC Bradycardia Right Atrium Pacing ^MDC_IDC_SET_LEADCHNL_RA_PACING_ CATHODE_LOCATION_^MDC Bradycardia Right Atrium Pacing ^MDC_IDC_SET_LEADCHNL_RA_PACING_ CATHODE_ELECTRODE_^MDC Bradycardia Right Atrium Pacing ^MDC_IDC_SET_LEADCHNL_RA_PACING_ CATHODE_LOCATION_2^MDC Bradycardia Right Atrium Pacing ^MDC_IDC_SET_LEADCHNL_RA_PACING_ CATHODE_ELECTRODE_2^MDC Bradycardia Right Atrium Pacing ^MDC_IDC_SET_LEADCHNL_RA_PACING_ CATHODE_LOCATION_3^MDC Bradycardia Right Atrium Pacing 73037^MDC_IDC_SET_LEADCHNL_RA_PACING_ CATHODE_ELECTRODE_3^MDC Bradycardia Right Atrium Pacing Pulse Width ^MDC_IDC_SET_LEADCHNL_RA_PACING_ PULSEWIDTH^MDC Bradycardia ^MDC_IDC_SET_LEADCHNL_RA_PACING_ AMPLITUDE^MDC V^volts^MDC
89 Connectivity Guide Paceart Integration 87 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Right Atrium Pacing Amplitude Bradycardia Right Atrium Pacing Adaptation Mode ^MDC_IDC_SET_LEADCHNL_RA_PACING_ CAPTURE_MODE^MDC Bradycardia Right Ventricle Pacing Polarity 7303^MDC_IDC_SET_LEADCHNL_RV_PACING_ POLARITY^MDC Bradycardia Right Ventricle Pacing 73093^MDC_IDC_SET_LEADCHNL_RV_PACING_ANODE_ LOCATION_^MDC Bradycardia Right Ventricle Pacing ^MDC_IDC_SET_LEADCHNL_RV_PACING_ANODE_ ELECTRODE_^MDC Bradycardia Right Ventricle Pacing 73094^MDC_IDC_SET_LEADCHNL_RV_PACING_ANODE_ LOCATION_2^MDC Bradycardia Right Ventricle Pacing ^MDC_IDC_SET_LEADCHNL_RV_PACING_ANODE_ ELECTRODE_2^MDC Bradycardia Right Ventricle Pacing 73095^MDC_IDC_SET_LEADCHNL_RV_PACING_ANODE_ LOCATION_3^MDC Bradycardia Right Ventricle Pacing ^MDC_IDC_SET_LEADCHNL_RV_PACING_ANODE_ ELECTRODE_3^MDC Bradycardia Right Ventricle Pacing 73032^MDC_IDC_SET_LEADCHNL_RV_PACING_ CATHODE_LOCATION_^MDC Bradycardia Right Ventricle Pacing ^MDC_IDC_SET_LEADCHNL_RV_PACING_ CATHODE_ELECTRODE_^MDC Bradycardia Right Ventricle Pacing ^MDC_IDC_SET_LEADCHNL_RV_PACING_ CATHODE_LOCATION_2^MDC
90 88 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Bradycardia Right Ventricle Pacing ^MDC_IDC_SET_LEADCHNL_RV_PACING_ CATHODE_ELECTRODE_2^MDC Bradycardia Right Ventricle Pacing ^MDC_IDC_SET_LEADCHNL_RV_PACING_ CATHODE_LOCATION_3^MDC Bradycardia Right Ventricle Pacing ^MDC_IDC_SET_LEADCHNL_RV_PACING_ CATHODE_ELECTRODE_3^MDC Bradycardia Right Ventricle Pacing Pulse Width ^MDC_IDC_SET_LEADCHNL_RV_PACING_ PULSEWIDTH^MDC Bradycardia Right Ventricle Pacing Amplitude ^MDC_IDC_SET_LEADCHNL_RV_PACING_ AMPLITUDE^MDC V^volts^MDC Bradycardia Right Ventricle Pacing Adaptation Mode ^MDC_IDC_SET_LEADCHNL_RV_PACING_ CAPTURE_MODE^MDC Outbound OB Programming Heart Failure Message Segments Paceart parameter type OB-2 OB-3 OB-4 OB-6 Heart Failure Ventricular Pacing Configuration ^MDC_IDC_SET_CRT_PACED_ CHAMBERS^MDC Heart Failure Ventricular Pacing Sequence 00024^MDT_PROG_CRT_VENTRICULAR_ FIR_CHAMBER_PACED^MDT VV Delay ^MDC_IDC_SET_CRT_LVRV_ DELAY^MDC Outbound OB Programming Message Segments Paceart parameter type OB-2 OB-3 OB-4 OB-6 Zone 73648^MDC_IDC_SET_ZONE_TYPE^MDC Zone Detection Status 00025^MDT_PROG_TACHY_ZONE_DETECTIONS_ATUS^MDT
91 Connectivity Guide Paceart Integration 89 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Zone Classifier 00026^MDT_PROG_TACHY_ZONE_DETECTIONS_CLASSIFIER^MDT Zone Detection Interval 73840^MDC_IDC_SET_ZONE_DETECTION_INTERVAL^MDC Zone Shared Detection Duration Fixed 00027^MDT_PROG_TACHY_ZONE_DETECTIONS_CRITERIA_ DURATION_SHARED_FIED^MDT s^seconds^mdc Zone Shared Detection Duration Beat Ratio Numerator 73904^MDC_IDC_SET_ZONE_DETECTION_BEATS_NUMERATOR^MDC {beats}^heartbeats^mdc Zone Shared Detection Duration Beat Ratio Denominator 73968^MDC_IDC_SET_ZONE_DETECTION_BEATS_ DENOMINATOR^MDC {beats}^heartbeats^mdc Zone Shared Detection Duration Beat Count 00028^MDT_PROG_TACHY_ZONE_DETECTIONS_CRITERIA_ DURATION_SHARED_BEATCOUNT^MDT {beats}^heartbeats^mdc Zone ATP Detection Duration Fixed 00029^MDT_PROG_TACHY_ZONE_DETECTIONS_CRITERIA_ DURATION_THERAPYSPECIFIC_ATP_FIED^MDT s^seconds^mdc Zone ATP Detection Duration Beat Ratio Numerator 00030^MDT_PROG_TACHY_ZONE_DETECTIONS_CRITERIA_ DURATION_THERAPYSPECIFIC_ATP_BEATRATIO_NUMERATOR^MDT {beats}^heartbeats^mdc Zone ATP Detection Duration Beat Ratio Denominator 0003^MDT_PROG_TACHY_ZONE_DETECTIONS_CRITERIA_ DURATION_THERAPYSPECIFIC_ATP_BEATRATIO_DENOMINATOR^MDT {beats}^heartbeats^mdc Zone ATP Detection 00032^MDT_PROG_TACHY_ZONE_DETECTIONS_CRITERIA_ DURATION_THERAPYSPECIFIC_ATP_BEATCOUNT^MDT {beats}^heartbeats^mdc
92 90 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Duration Beat Count Zone Detection Duration Fixed 00033^MDT_PROG_TACHY_ZONE_DETECTIONS_CRITERIA_ DURATION_THERAPYSPECIFIC_SHOCK_FIED^MDT s^seconds^mdc Zone Detection Duration Beat Ratio Numerator 00034^MDT_PROG_TACHY_ZONE_DETECTIONS_CRITERIA_ DURATION_THERAPYSPECIFIC_SHOCK_BEATRATIO_ NUMERATOR^MDT {beats}^heartbeats^mdc Zone Detection Duration Beat Ratio Denominator 00035^MDT_PROG_TACHY_ZONE_DETECTIONS_CRITERIA_ DURATION_THERAPYSPECIFIC_SHOCK_BEATRATIO_ DENOMINATOR^MDT {beats}^heartbeats^mdc Zone Detection Duration Beat Count 00036^MDT_PROG_TACHY_ZONE_DETECTIONS_CRITERIA_ DURATION_THERAPYSPECIFIC_SHOCK_BEATCOUNT^MDT {beats}^heartbeats^mdc Zone Redetection Interval 00037^MDT_PROG_TACHY_ZONE_DETECTIONS_REDETECTION_ CRITERIA_INTERVAL^MDT Zone Shared Redetection Duration Fixed 00038^MDT_PROG_TACHY_ZONE_DETECTIONS_REDETECTION_ CRITERIA_DURATION_SHARED_FIED^MDT s^seconds^mdc Zone Shared Redetection Duration Beat Ratio Numerator 00039^MDT_PROG_TACHY_ZONE_DETECTIONS_REDETECTION_ CRITERIA_DURATION_SHARED_BEATRATIO_NUMERATOR^MDT {beats}^heartbeats^mdc Zone Shared Redetection Duration Beat Ratio Denominator 00040^MDT_PROG_TACHY_ZONE_DETECTIONS_REDETECTION_ CRITERIA_DURATION_SHARED_BEATRATIO_DENOMINATOR^MDT {beats}^heartbeats^mdc Zone Shared Redetection Duration Beat Count 0004^MDT_PROG_TACHY_ZONE_DETECTIONS_REDETECTION_ CRITERIA_DURATION_SHARED_BEATCOUNT^MDT {beats}^heartbeats^mdc
93 Connectivity Guide Paceart Integration 9 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Zone ATP Redetection Duration Fixed 00042^MDT_PROG_TACHY_ZONE_DETECTIONS_REDETECTION_ CRITERIA_DURATION_THERAPYSPECIFIC_ATP_FIED^MDT s^seconds^mdc Zone ATP Redetection Duration Beat Ratio Numerator 00043^MDT_PROG_TACHY_ZONE_DETECTIONS_REDETECTION_ CRITERIA_DURATION_THERAPYSPECIFIC_ATP_BEATRATIO_ NUMERATOR^MDT {beats}^heartbeats^mdc Zone ATP Redetection Duration Beat Ratio Denominator 00044^MDT_PROG_TACHY_ZONE_DETECTIONS_REDETECTION_ CRITERIA_DURATION_THERAPYSPECIFIC_ATP_BEATRATIO_ DENOMINATOR^MDT {beats}^heartbeats^mdc Zone ATP Redetection Duration Beat Count 00045^MDT_PROG_TACHY_ZONE_DETECTIONS_REDETECTION_ CRITERIA_DURATION_THERAPYSPECIFIC_ATP_BEATCOUNT^MDT {beats}^heartbeats^mdc Zone Redetection Duration Fixed 00046^MDT_PROG_TACHY_ZONE_DETECTIONS_REDETECTION_ CRITERIA_DURATION_THERAPYSPECIFIC_SHOCK_FIED^MDT s^seconds^mdc Zone Redetection Duration Beat Ratio Numerator 00047^MDT_PROG_TACHY_ZONE_DETECTIONS_REDETECTION_ CRITERIA_DURATION_THERAPYSPECIFIC_SHOCK_BEATRATIO_ NUMERATOR^MDT {beats}^heartbeats^mdc Zone Redetection Duration Beat Ratio Denominator 00048^MDT_PROG_TACHY_ZONE_DETECTIONS_REDETECTION_ CRITERIA_DURATION_THERAPYSPECIFIC_SHOCK_BEATRATIO_ DENOMINATOR^MDT {beats}^heartbeats^mdc Zone Redetection Duration Beat Count 00049^MDT_PROG_TACHY_ZONE_DETECTIONS_REDETECTION_ CRITERIA_DURATION_THERAPYSPECIFIC_SHOCK_BEATCOUNT^MDT {beats}^heartbeats^mdc Zone Sudden Onset Status 00050^MDT_PROG_TACHY_ZONE_DETECTIONS_SUDDENONSET_ ATUS^MDT Zone Sudden Onset 0005^MDT_PROG_TACHY_ZONE_DETECTIONS_SUDDENONSET_ CRITERIA_DURATION_FIED^MDT
94 92 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Duration Fixed Zone Sudden Onset Duration Percent 00052^MDT_PROG_TACHY_ZONE_DETECTIONS_SUDDENONSET_ CRITERIA_DURATION_PERCENT^MDT %^percent^mdc Zone Rate Stability Status 00053^MDT_PROG_TACHY_ZONE_DETECTIONS_RATEABILITY_ ATUS^MDT Zone Rate Stability Duration 00054^MDT_PROG_TACHY_ZONE_DETECTIONS_RATEABILITY_ CRITERIA_DURATION^MDT Zone Sustained High Rate To Current Zone Status 00055^MDT_PROG_TACHY_ZONE_DETECTIONS_ SUAINEDHIGHRATETOCURRENTZONE_ATUS^MDT Zone Sustained High Rate To Current Zone Duration 00056^MDT_PROG_TACHY_ZONE_DETECTIONS_ SUAINEDHIGHRATETOCURRENTZONE_CRITERIA_DURATION^MDT s^seconds^mdc Zone Sustained High Rate To Current Zone Rate 00057^MDT_PROG_TACHY_ZONE_DETECTIONS_ SUAINEDHIGHRATETOCURRENTZONE_CRITERIA_RATE^MDT {beats}/min^heartbeats^mdc Zone Sustained High Rate To VF Zone Status 00058^MDT_PROG_TACHY_ZONE_DETECTIONS_ SUAINEDHIGHRATETOVFZONE_ATUS^MDT Zone Sustained High Rate To VF Zone Duration 00059^MDT_PROG_TACHY_ZONE_DETECTIONS_ SUAINEDHIGHRATETOVFZONE_CRITERIA_DURATION^MDT s^seconds^mdc Zone Sustained High Rate To VF Zone Rate 00060^MDT_PROG_TACHY_ZONE_DETECTIONS_ SUAINEDHIGHRATETOVFZONE_CRITERIA_RATE^MDT {beats}/min^heartbeats^mdc
95 Connectivity Guide Paceart Integration 93 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Zone QRS Morphology Status 0006^MDT_PROG_TACHY_ZONE_DETECTIONS_QRSMORPHOLOGY_ ATUS^MDT Zone QRS Morphology Match 00062^MDT_PROG_TACHY_ZONE_DETECTIONS_QRSMORPHOLOGY_ CRITERIA_MATCH^MDT %^percent^mdc Sequence ID 00063^MDT_PROG_TACHY_ZONE_THERAPIES SEQUENCEID^MDT Sequence ID 00064^MDT_PROG_TACHY_ZONE_THERAPIES_2_SEQUENCEID^MDT Sequence ID 00065^MDT_PROG_TACHY_ZONE_THERAPIES_3_SEQUENCEID^MDT Sequence ID 00066^MDT_PROG_TACHY_ZONE_THERAPIES_4_SEQUENCEID^MDT Sequence ID 00067^MDT_PROG_TACHY_ZONE_THERAPIES_5_SEQUENCEID^MDT Sequence ID 00068^MDT_PROG_TACHY_ZONE_THERAPIES_6_SEQUENCEID^MDT Sequence ID 00069^MDT_PROG_TACHY_ZONE_THERAPIES_7_SEQUENCEID^MDT Sequence ID 00070^MDT_PROG_TACHY_ZONE_THERAPIES_8_SEQUENCEID^MDT Sequence ID 0007^MDT_PROG_TACHY_ZONE_THERAPIES_9_SEQUENCEID^MDT Sequence ID 00072^MDT_PROG_TACHY_ZONE_THERAPIES_0_SEQUENCEID^MDT Sequence ID 00073^MDT_PROG_TACHY_ZONE_THERAPIES SEQUENCEID^MDT
96 94 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Sequence ID 00074^MDT_PROG_TACHY_ZONE_THERAPIES_2_SEQUENCEID^MDT Sequence ID 00075^MDT_PROG_TACHY_ZONE_THERAPIES_3_SEQUENCEID^MDT Sequence ID 00076^MDT_PROG_TACHY_ZONE_THERAPIES_4_SEQUENCEID^MDT Sequence ID 00077^MDT_PROG_TACHY_ZONE_THERAPIES_5_SEQUENCEID^MDT Sequence ID 00078^MDT_PROG_TACHY_ZONE_THERAPIES_6_SEQUENCEID^MDT Sequence ID 00079^MDT_PROG_TACHY_ZONE_THERAPIES_7_SEQUENCEID^MDT Sequence ID 00080^MDT_PROG_TACHY_ZONE_THERAPIES_8_SEQUENCEID^MDT Sequence ID 0008^MDT_PROG_TACHY_ZONE_THERAPIES_9_SEQUENCEID^MDT Sequence ID 00082^MDT_PROG_TACHY_ZONE_THERAPIES_20_SEQUENCEID^MDT Status 00083^MDT_PROG_TACHY_ZONE_THERAPIES ATUS^MDT Status 00084^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATUS^MDT Status 00085^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATUS^MDT Status 00086^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATUS^MDT
97 Connectivity Guide Paceart Integration 95 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Status 00087^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATUS^MDT Status 00088^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATUS^MDT Status 00089^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATUS^MDT Status 00090^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATUS^MDT Status 0009^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATUS^MDT Status 00092^MDT_PROG_TACHY_ZONE_THERAPIES_0_ATUS^MDT Status 00093^MDT_PROG_TACHY_ZONE_THERAPIES ATUS^MDT Status 00094^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATUS^MDT Status 00095^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATUS^MDT Status 00096^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATUS^MDT Status 00097^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATUS^MDT Status 00098^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATUS^MDT Status 00099^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATUS^MDT
98 96 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Status 0000^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATUS^MDT Status 000^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATUS^MDT Status 0002^MDT_PROG_TACHY_ZONE_THERAPIES_20_ATUS^MDT 0003^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ TYPE^MDT 0004^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ TYPE^MDT 0005^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ TYPE^MDT 0006^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ TYPE^MDT 0007^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ TYPE^MDT 0008^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ TYPE^MDT 0009^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ TYPE^MDT 000^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ TYPE^MDT 00^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ TYPE^MDT 002^MDT_PROG_TACHY_ZONE_THERAPIES_0_ATPTHERAPY_ TYPE^MDT
99 Connectivity Guide Paceart Integration 97 Paceart parameter type OB-2 OB-3 OB-4 OB-6 003^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ TYPE^MDT 004^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ TYPE^MDT 005^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ TYPE^MDT 006^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ TYPE^MDT 007^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ TYPE^MDT 008^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ TYPE^MDT 009^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ TYPE^MDT 0020^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ TYPE^MDT 002^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ TYPE^MDT 0022^MDT_PROG_TACHY_ZONE_THERAPIES_20_ATPTHERAPY_ TYPE^MDT Description 0023^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ DESCRIPTION^MDT Description 0024^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ DESCRIPTION^MDT Description 0025^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ DESCRIPTION^MDT
100 98 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Description 0026^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ DESCRIPTION^MDT Description 0027^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ DESCRIPTION^MDT Description 0028^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ DESCRIPTION^MDT Description 0029^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ DESCRIPTION^MDT Description 0030^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ DESCRIPTION^MDT Description 003^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ DESCRIPTION^MDT Description 0032^MDT_PROG_TACHY_ZONE_THERAPIES_0_ATPTHERAPY_ DESCRIPTION^MDT Description 0033^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ DESCRIPTION^MDT Description 0034^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ DESCRIPTION^MDT Description 0035^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ DESCRIPTION^MDT Description 0036^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ DESCRIPTION^MDT Description 0037^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ DESCRIPTION^MDT Description 0038^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ DESCRIPTION^MDT
101 Connectivity Guide Paceart Integration 99 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Description 0039^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ DESCRIPTION^MDT Description 0040^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ DESCRIPTION^MDT Description 004^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ DESCRIPTION^MDT Description 0042^MDT_PROG_TACHY_ZONE_THERAPIES_20_ATPTHERAPY_ DESCRIPTION^MDT Timing 0043^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ TIMING^MDT Timing 0044^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ TIMING^MDT Timing 0045^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ TIMING^MDT Timing 0046^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ TIMING^MDT Timing 0047^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ TIMING^MDT Timing 0048^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ TIMING^MDT Timing 0049^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ TIMING^MDT Timing 0050^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ TIMING^MDT Timing 005^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ TIMING^MDT
102 00 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Timing 0052^MDT_PROG_TACHY_ZONE_THERAPIES_0_ATPTHERAPY_ TIMING^MDT Timing 0053^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ TIMING^MDT Timing 0054^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ TIMING^MDT Timing 0055^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ TIMING^MDT Timing 0056^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ TIMING^MDT Timing 0057^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ TIMING^MDT Timing 0058^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ TIMING^MDT Timing 0059^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ TIMING^MDT Timing 0060^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ TIMING^MDT Timing 006^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ TIMING^MDT Timing 0062^MDT_PROG_TACHY_ZONE_THERAPIES_20_ATPTHERAPY_ TIMING^MDT Amplitude 0063^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ AMPLITUDE^MDT V^volts^MDC Amplitude 0064^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ AMPLITUDE^MDT V^volts^MDC
103 Connectivity Guide Paceart Integration 0 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Amplitude 0065^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ AMPLITUDE^MDT V^volts^MDC Amplitude 0066^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ AMPLITUDE^MDT V^volts^MDC Amplitude 0067^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ AMPLITUDE^MDT V^volts^MDC Amplitude 0068^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ AMPLITUDE^MDT V^volts^MDC Amplitude 0069^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ AMPLITUDE^MDT V^volts^MDC Amplitude 0070^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ AMPLITUDE^MDT V^volts^MDC Amplitude 007^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ AMPLITUDE^MDT V^volts^MDC Amplitude 0072^MDT_PROG_TACHY_ZONE_THERAPIES_0_ATPTHERAPY_ AMPLITUDE^MDT V^volts^MDC Amplitude 0073^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ AMPLITUDE^MDT V^volts^MDC Amplitude 0074^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ AMPLITUDE^MDT V^volts^MDC Amplitude 0075^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ AMPLITUDE^MDT V^volts^MDC Amplitude 0076^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ AMPLITUDE^MDT V^volts^MDC Amplitude 0077^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ AMPLITUDE^MDT V^volts^MDC
104 02 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Amplitude 0078^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ AMPLITUDE^MDT V^volts^MDC Amplitude 0079^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ AMPLITUDE^MDT V^volts^MDC Amplitude 0080^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ AMPLITUDE^MDT V^volts^MDC Amplitude 008^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ AMPLITUDE^MDT V^volts^MDC Amplitude 0082^MDT_PROG_TACHY_ZONE_THERAPIES_20_ATPTHERAPY_ AMPLITUDE^MDT V^volts^MDC Pulse Width 0083^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ PULSEWIDTH^MDT Pulse Width 0084^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ PULSEWIDTH^MDT Pulse Width 0085^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ PULSEWIDTH^MDT Pulse Width 0086^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ PULSEWIDTH^MDT Pulse Width 0087^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ PULSEWIDTH^MDT Pulse Width 0088^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ PULSEWIDTH^MDT Pulse Width 0089^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ PULSEWIDTH^MDT Pulse Width 0090^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ PULSEWIDTH^MDT
105 Connectivity Guide Paceart Integration 03 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Pulse Width 009^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ PULSEWIDTH^MDT Pulse Width 0092^MDT_PROG_TACHY_ZONE_THERAPIES_0_ATPTHERAPY_ PULSEWIDTH^MDT Pulse Width 0093^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ PULSEWIDTH^MDT Pulse Width 0094^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ PULSEWIDTH^MDT Pulse Width 0095^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ PULSEWIDTH^MDT Pulse Width 0095^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ PULSEWIDTH^MDT Pulse Width 0096^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ PULSEWIDTH^MDT Pulse Width 0097^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ PULSEWIDTH^MDT Pulse Width 0098^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ PULSEWIDTH^MDT Pulse Width 0099^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ PULSEWIDTH^MDT Pulse Width 00200^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ PULSEWIDTH^MDT Pulse Width 0020^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ PULSEWIDTH^MDT Pulse Width 00202^MDT_PROG_TACHY_ZONE_THERAPIES_20_ATPTHERAPY_ PULSEWIDTH^MDT
106 04 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Stimuli Count 00203^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ IMULICOUNT^MDT Stimuli Count 00204^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ IMULICOUNT^MDT Stimuli Count 00205^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ IMULICOUNT^MDT Stimuli Count 00206^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ IMULICOUNT^MDT Stimuli Count 00207^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ IMULICOUNT^MDT Stimuli Count 00208^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ IMULICOUNT^MDT Stimuli Count 00209^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ IMULICOUNT^MDT Stimuli Count 0020^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ IMULICOUNT^MDT Stimuli Count 002^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ IMULICOUNT^MDT Stimuli Count 0022^MDT_PROG_TACHY_ZONE_THERAPIES_0_ATPTHERAPY_ IMULICOUNT^MDT Stimuli Count 0023^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ IMULICOUNT^MDT Stimuli Count 0024^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ IMULICOUNT^MDT Stimuli Count 0025^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ IMULICOUNT^MDT
107 Connectivity Guide Paceart Integration 05 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Stimuli Count 0026^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ IMULICOUNT^MDT Stimuli Count 0027^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ IMULICOUNT^MDT Stimuli Count 0028^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ IMULICOUNT^MDT Stimuli Count 0029^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ IMULICOUNT^MDT Stimuli Count 00220^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ IMULICOUNT^MDT Stimuli Count 0022^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ IMULICOUNT^MDT Stimuli Count 00222^MDT_PROG_TACHY_ZONE_THERAPIES_20_ATPTHERAPY_ IMULICOUNT^MDT Coupling Interval Length Fixed 00223^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ COUPLINGINTERVALLENGTH_FIED^MDT Coupling Interval Length Fixed 00224^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ COUPLINGINTERVALLENGTH_FIED^MDT Coupling Interval Length Fixed 00225^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ COUPLINGINTERVALLENGTH_FIED^MDT Coupling Interval Length Fixed 00226^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ COUPLINGINTERVALLENGTH_FIED^MDT Coupling 00227^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ COUPLINGINTERVALLENGTH_FIED^MDT
108 06 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Interval Length Fixed Coupling Interval Length Fixed 00228^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ COUPLINGINTERVALLENGTH_FIED^MDT Coupling Interval Length Fixed 00229^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ COUPLINGINTERVALLENGTH_FIED^MDT Coupling Interval Length Fixed 00230^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ COUPLINGINTERVALLENGTH_FIED^MDT Coupling Interval Length Fixed 0023^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ COUPLINGINTERVALLENGTH_FIED^MDT Coupling Interval Length Fixed 00232^MDT_PROG_TACHY_ZONE_THERAPIES_0_ATPTHERAPY_ COUPLINGINTERVALLENGTH_FIED^MDT Coupling Interval Length Fixed 00233^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ COUPLINGINTERVALLENGTH_FIED^MDT Coupling Interval Length Fixed 00234^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ COUPLINGINTERVALLENGTH_FIED^MDT Coupling Interval Length Fixed 00235^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ COUPLINGINTERVALLENGTH_FIED^MDT Coupling Interval Length Fixed 00236^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ COUPLINGINTERVALLENGTH_FIED^MDT 00237^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ COUPLINGINTERVALLENGTH_FIED^MDT
109 Connectivity Guide Paceart Integration 07 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Coupling Interval Length Fixed Coupling Interval Length Fixed 00238^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ COUPLINGINTERVALLENGTH_FIED^MDT Coupling Interval Length Fixed 00239^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ COUPLINGINTERVALLENGTH_FIED^MDT Coupling Interval Length Fixed 00240^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ COUPLINGINTERVALLENGTH_FIED^MDT Coupling Interval Length Fixed 0024^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ COUPLINGINTERVALLENGTH_FIED^MDT Coupling Interval Length Fixed 00242^MDT_PROG_TACHY_ZONE_THERAPIES_20_ATPTHERAPY_ COUPLINGINTERVALLENGTH_FIED^MDT Coupling Interval Length Percent 00243^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ COUPLINGINTERVALLENGTH_PERCENT^MDT %^percent^mdc Coupling Interval Length Percent 00244^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ COUPLINGINTERVALLENGTH_PERCENT^MDT %^percent^mdc Coupling Interval Length Percent 00245^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ COUPLINGINTERVALLENGTH_PERCENT^MDT %^percent^mdc Coupling Interval Length Percent 00246^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ COUPLINGINTERVALLENGTH_PERCENT^MDT %^percent^mdc
110 08 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Coupling Interval Length Percent 00247^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ COUPLINGINTERVALLENGTH_PERCENT^MDT %^percent^mdc Coupling Interval Length Percent 00248^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ COUPLINGINTERVALLENGTH_PERCENT^MDT %^percent^mdc Coupling Interval Length Percent 00249^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ COUPLINGINTERVALLENGTH_PERCENT^MDT %^percent^mdc Coupling Interval Length Percent 00250^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ COUPLINGINTERVALLENGTH_PERCENT^MDT %^percent^mdc Coupling Interval Length Percent 0025^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ COUPLINGINTERVALLENGTH_PERCENT^MDT %^percent^mdc Coupling Interval Length Percent 00252^MDT_PROG_TACHY_ZONE_THERAPIES_0_ATPTHERAPY_ COUPLINGINTERVALLENGTH_PERCENT^MDT %^percent^mdc Coupling Interval Length Percent 00253^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ COUPLINGINTERVALLENGTH_PERCENT^MDT %^percent^mdc Coupling Interval Length Percent 00254^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ COUPLINGINTERVALLENGTH_PERCENT^MDT %^percent^mdc Coupling Interval 00255^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ COUPLINGINTERVALLENGTH_PERCENT^MDT %^percent^mdc
111 Connectivity Guide Paceart Integration 09 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Length Percent Coupling Interval Length Percent 00256^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ COUPLINGINTERVALLENGTH_PERCENT^MDT %^percent^mdc Coupling Interval Length Percent 00257^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ COUPLINGINTERVALLENGTH_PERCENT^MDT %^percent^mdc Coupling Interval Length Percent 00258^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ COUPLINGINTERVALLENGTH_PERCENT^MDT %^percent^mdc Coupling Interval Length Percent 00259^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ COUPLINGINTERVALLENGTH_PERCENT^MDT %^percent^mdc Coupling Interval Length Percent 00260^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ COUPLINGINTERVALLENGTH_PERCENT^MDT %^percent^mdc Coupling Interval Length Percent 0026^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ COUPLINGINTERVALLENGTH_PERCENT^MDT %^percent^mdc Coupling Interval Length Percent 00262^MDT_PROG_TACHY_ZONE_THERAPIES_20_ATPTHERAPY_ COUPLINGINTERVALLENGTH_PERCENT^MDT %^percent^mdc Coupling Interval Decrement 00263^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ COUPLINGINTERVALDECREMENT^MDT Coupling 00264^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ COUPLINGINTERVALDECREMENT^MDT
112 0 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Interval Decrement Coupling Interval Decrement 00265^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ COUPLINGINTERVALDECREMENT^MDT Coupling Interval Decrement 00266^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ COUPLINGINTERVALDECREMENT^MDT Coupling Interval Decrement 00267^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ COUPLINGINTERVALDECREMENT^MDT Coupling Interval Decrement 00268^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ COUPLINGINTERVALDECREMENT^MDT Coupling Interval Decrement 00269^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ COUPLINGINTERVALDECREMENT^MDT Coupling Interval Decrement 00270^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ COUPLINGINTERVALDECREMENT^MDT Coupling Interval Decrement 0027^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ COUPLINGINTERVALDECREMENT^MDT Coupling Interval Decrement 00272^MDT_PROG_TACHY_ZONE_THERAPIES_0_ATPTHERAPY_ COUPLINGINTERVALDECREMENT^MDT Coupling Interval Decrement 00273^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ COUPLINGINTERVALDECREMENT^MDT 00274^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ COUPLINGINTERVALDECREMENT^MDT
113 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Coupling Interval Decrement Coupling Interval Decrement 00275^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ COUPLINGINTERVALDECREMENT^MDT Coupling Interval Decrement 00276^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ COUPLINGINTERVALDECREMENT^MDT Coupling Interval Decrement 00277^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ COUPLINGINTERVALDECREMENT^MDT Coupling Interval Decrement 00278^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ COUPLINGINTERVALDECREMENT^MDT Coupling Interval Decrement 00279^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ COUPLINGINTERVALDECREMENT^MDT Coupling Interval Decrement 00280^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ COUPLINGINTERVALDECREMENT^MDT Coupling Interval Decrement 0028^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ COUPLINGINTERVALDECREMENT^MDT Coupling Interval Decrement 00282^MDT_PROG_TACHY_ZONE_THERAPIES_20_ATPTHERAPY_ COUPLINGINTERVALDECREMENT^MDT Ramp Decrement 00283^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ RAMPDECREMENT^MDT 00284^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ RAMPDECREMENT^MDT
114 2 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Ramp Decrement Ramp Decrement 00285^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ RAMPDECREMENT^MDT Ramp Decrement 00286^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ RAMPDECREMENT^MDT Ramp Decrement 00287^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ RAMPDECREMENT^MDT Ramp Decrement 00288^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ RAMPDECREMENT^MDT Ramp Decrement 00289^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ RAMPDECREMENT^MDT Ramp Decrement 00290^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ RAMPDECREMENT^MDT Ramp Decrement 0029^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ RAMPDECREMENT^MDT Ramp Decrement 00292^MDT_PROG_TACHY_ZONE_THERAPIES_0_ATPTHERAPY_ RAMPDECREMENT^MDT Ramp Decrement 00293^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ RAMPDECREMENT^MDT Ramp Decrement 00294^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ RAMPDECREMENT^MDT Ramp Decrement 00295^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ RAMPDECREMENT^MDT
115 Connectivity Guide Paceart Integration 3 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Ramp Decrement 00296^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ RAMPDECREMENT^MDT Ramp Decrement 00297^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ RAMPDECREMENT^MDT Ramp Decrement 00298^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ RAMPDECREMENT^MDT Ramp Decrement 00299^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ RAMPDECREMENT^MDT Ramp Decrement 00300^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ RAMPDECREMENT^MDT Ramp Decrement 0030^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ RAMPDECREMENT^MDT Ramp Decrement 00302^MDT_PROG_TACHY_ZONE_THERAPIES_20_ATPTHERAPY_ RAMPDECREMENT^MDT Minimum Burst Cycle Length 00303^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ MINIMUMBURCYCLELENGTH^MDT Minimum Burst Cycle Length 00304^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ MINIMUMBURCYCLELENGTH^MDT Minimum Burst Cycle Length 00305^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ MINIMUMBURCYCLELENGTH^MDT Minimum 00306^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ MINIMUMBURCYCLELENGTH^MDT
116 4 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Burst Cycle Length Minimum Burst Cycle Length 00307^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ MINIMUMBURCYCLELENGTH^MDT Minimum Burst Cycle Length 00308^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ MINIMUMBURCYCLELENGTH^MDT Minimum Burst Cycle Length 00309^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ MINIMUMBURCYCLELENGTH^MDT Minimum Burst Cycle Length 0030^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ MINIMUMBURCYCLELENGTH^MDT Minimum Burst Cycle Length 003^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ MINIMUMBURCYCLELENGTH^MDT Minimum Burst Cycle Length 0032^MDT_PROG_TACHY_ZONE_THERAPIES_0_ATPTHERAPY_ MINIMUMBURCYCLELENGTH^MDT Minimum Burst Cycle Length 0033^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ MINIMUMBURCYCLELENGTH^MDT Minimum Burst Cycle Length 0034^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ MINIMUMBURCYCLELENGTH^MDT Minimum Burst Cycle Length 0035^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ MINIMUMBURCYCLELENGTH^MDT 0036^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ MINIMUMBURCYCLELENGTH^MDT
117 Connectivity Guide Paceart Integration 5 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Minimum Burst Cycle Length Minimum Burst Cycle Length 0037^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ MINIMUMBURCYCLELENGTH^MDT Minimum Burst Cycle Length 0038^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ MINIMUMBURCYCLELENGTH^MDT Minimum Burst Cycle Length 0039^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ MINIMUMBURCYCLELENGTH^MDT Minimum Burst Cycle Length 00320^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ MINIMUMBURCYCLELENGTH^MDT Minimum Burst Cycle Length 0032^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ MINIMUMBURCYCLELENGTH^MDT Minimum Burst Cycle Length 00322^MDT_PROG_TACHY_ZONE_THERAPIES_20_ATPTHERAPY_ MINIMUMBURCYCLELENGTH^MDT Number Of Sequences 00323^ MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ NUMBEROFSEQUENCES^MDT Number Of Sequences 00324^ MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ NUMBEROFSEQUENCES^MDT Number Of Sequences 00325^ MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ NUMBEROFSEQUENCES^MDT Number Of Sequences 00326^ MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ NUMBEROFSEQUENCES^MDT
118 6 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Number Of Sequences 00327^ MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ NUMBEROFSEQUENCES^MDT Number Of Sequences 00328^ MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ NUMBEROFSEQUENCES^MDT Number Of Sequences 00329^ MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ NUMBEROFSEQUENCES^MDT Number Of Sequences 00330^ MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ NUMBEROFSEQUENCES^MDT Number Of Sequences 0033^ MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ NUMBEROFSEQUENCES^MDT Number Of Sequences 00332^ MDT_PROG_TACHY_ZONE_THERAPIES_0_ATPTHERAPY_ NUMBEROFSEQUENCES^MDT Number Of Sequences 00333^ MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ NUMBEROFSEQUENCES^MDT Number Of Sequences 00334^ MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ NUMBEROFSEQUENCES^MDT Number Of Sequences 00335^ MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ NUMBEROFSEQUENCES^MDT Number Of Sequences 00336^ MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ NUMBEROFSEQUENCES^MDT Number Of Sequences 00337^ MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ NUMBEROFSEQUENCES^MDT 00338^ MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ NUMBEROFSEQUENCES^MDT
119 Connectivity Guide Paceart Integration 7 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Number Of Sequences Number Of Sequences 00339^ MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ NUMBEROFSEQUENCES^MDT Number Of Sequences 00340^ MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ NUMBEROFSEQUENCES^MDT Number Of Sequences 0034^ MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ NUMBEROFSEQUENCES^MDT Number Of Sequences 00342^ MDT_PROG_TACHY_ZONE_THERAPIES_20_ATPTHERAPY_ NUMBEROFSEQUENCES^MDT Maximum Number Of Pulses 00343^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ MAIMUMNUMBEROFPULSES^MDT Maximum Number Of Pulses 00344^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ MAIMUMNUMBEROFPULSES^MDT Maximum Number Of Pulses 00345^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ MAIMUMNUMBEROFPULSES^MDT Maximum Number Of Pulses 00346^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ MAIMUMNUMBEROFPULSES^MDT Maximum Number Of Pulses 00347^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ MAIMUMNUMBEROFPULSES^MDT Maximum 00348^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ MAIMUMNUMBEROFPULSES^MDT
120 8 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Number Of Pulses Maximum Number Of Pulses 00349^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ MAIMUMNUMBEROFPULSES^MDT Maximum Number Of Pulses 00350^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ MAIMUMNUMBEROFPULSES^MDT Maximum Number Of Pulses 0035^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ MAIMUMNUMBEROFPULSES^MDT Maximum Number Of Pulses 00352^MDT_PROG_TACHY_ZONE_THERAPIES_0_ATPTHERAPY_ MAIMUMNUMBEROFPULSES^MDT Maximum Number Of Pulses 00353^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ MAIMUMNUMBEROFPULSES^MDT Maximum Number Of Pulses 00354^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ MAIMUMNUMBEROFPULSES^MDT Maximum Number Of Pulses 00355^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ MAIMUMNUMBEROFPULSES^MDT Maximum Number Of Pulses 00356^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ MAIMUMNUMBEROFPULSES^MDT Maximum Number Of Pulses 00357^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ MAIMUMNUMBEROFPULSES^MDT 00358^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ MAIMUMNUMBEROFPULSES^MDT
121 Connectivity Guide Paceart Integration 9 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Maximum Number Of Pulses Maximum Number Of Pulses 00359^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ MAIMUMNUMBEROFPULSES^MDT Maximum Number Of Pulses 00360^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ MAIMUMNUMBEROFPULSES^MDT Maximum Number Of Pulses 0036^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ MAIMUMNUMBEROFPULSES^MDT Maximum Number Of Pulses 00362^MDT_PROG_TACHY_ZONE_THERAPIES_20_ATPTHERAPY_ MAIMUMNUMBEROFPULSES^MDT Pulse Increment 00363^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ PULSEINCREMENT^MDT Pulse Increment 00364^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ PULSEINCREMENT^MDT Pulse Increment 00365^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ PULSEINCREMENT^MDT Pulse Increment 00366^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ PULSEINCREMENT^MDT Pulse Increment 00367^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ PULSEINCREMENT^MDT Pulse Increment 00368^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ PULSEINCREMENT^MDT
122 20 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Pulse Increment 00369^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ PULSEINCREMENT^MDT Pulse Increment 00370^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ PULSEINCREMENT^MDT Pulse Increment 0037^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ PULSEINCREMENT^MDT Pulse Increment 00372^MDT_PROG_TACHY_ZONE_THERAPIES_0_ATPTHERAPY_ PULSEINCREMENT^MDT Pulse Increment 00373^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ PULSEINCREMENT^MDT Pulse Increment 00374^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ PULSEINCREMENT^MDT Pulse Increment 00375^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ PULSEINCREMENT^MDT Pulse Increment 00376^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ PULSEINCREMENT^MDT Pulse Increment 00377^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ PULSEINCREMENT^MDT Pulse Increment 00378^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ PULSEINCREMENT^MDT Pulse Increment 00379^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ PULSEINCREMENT^MDT 00380^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ PULSEINCREMENT^MDT
123 Connectivity Guide Paceart Integration 2 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Pulse Increment Pulse Increment 0038^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ PULSEINCREMENT^MDT Pulse Increment 00382^MDT_PROG_TACHY_ZONE_THERAPIES_20_ATPTHERAPY_ PULSEINCREMENT^MDT Scan Decrement 00383^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ SCANDECREMENT^MDT Scan Decrement 00384^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ SCANDECREMENT^MDT Scan Decrement 00385^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ SCANDECREMENT^MDT Scan Decrement 00386^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ SCANDECREMENT^MDT Scan Decrement 00387^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ SCANDECREMENT^MDT Scan Decrement 00388^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ SCANDECREMENT^MDT Scan Decrement 00389^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ SCANDECREMENT^MDT Scan Decrement 00390^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ SCANDECREMENT^MDT 0039^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ SCANDECREMENT^MDT
124 22 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Scan Decrement Scan Decrement 00392^MDT_PROG_TACHY_ZONE_THERAPIES_0_ATPTHERAPY_ SCANDECREMENT^MDT Scan Decrement 00393^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ SCANDECREMENT^MDT Scan Decrement 00394^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ SCANDECREMENT^MDT Scan Decrement 00395^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ SCANDECREMENT^MDT Scan Decrement 00396^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ SCANDECREMENT^MDT Scan Decrement 00397^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ SCANDECREMENT^MDT Scan Decrement 00398^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ SCANDECREMENT^MDT Scan Decrement 00399^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ SCANDECREMENT^MDT Scan Decrement 00400^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ SCANDECREMENT^MDT Scan Decrement 0040^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ SCANDECREMENT^MDT Scan Decrement 00402^MDT_PROG_TACHY_ZONE_THERAPIES_20_ATPTHERAPY_ SCANDECREMENT^MDT
125 Connectivity Guide Paceart Integration 23 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Smart Mode 00403^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ SMARTMODE^MDT Smart Mode 00404^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ SMARTMODE^MDT Smart Mode 00405^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ SMARTMODE^MDT Smart Mode 00406^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ SMARTMODE^MDT Smart Mode 00407^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ SMARTMODE^MDT Smart Mode 00408^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ SMARTMODE^MDT Smart Mode 00409^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ SMARTMODE^MDT Smart Mode 0040^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ SMARTMODE^MDT Smart Mode 004^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ SMARTMODE^MDT Smart Mode 0042^MDT_PROG_TACHY_ZONE_THERAPIES_0_ATPTHERAPY_ SMARTMODE^MDT Smart Mode 0043^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ SMARTMODE^MDT Smart Mode 0044^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ SMARTMODE^MDT Smart Mode 0045^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ SMARTMODE^MDT
126 24 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Smart Mode 0046^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ SMARTMODE^MDT Smart Mode 0047^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ SMARTMODE^MDT Smart Mode 0048^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ SMARTMODE^MDT Smart Mode 0049^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ SMARTMODE^MDT Smart Mode 00420^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ SMARTMODE^MDT Smart Mode 0042^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ SMARTMODE^MDT Smart Mode 00422^MDT_PROG_TACHY_ZONE_THERAPIES_20_ATPTHERAPY_ SMARTMODE^MDT Disabled By Smart Mode 00423^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ THERAPYDISABLEDBYSMARTMODE^MDT Disabled By Smart Mode 00424^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ THERAPYDISABLEDBYSMARTMODE^MDT Disabled By Smart Mode 00425^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ THERAPYDISABLEDBYSMARTMODE^MDT Disabled By Smart Mode 00426^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ THERAPYDISABLEDBYSMARTMODE^MDT Disabled By Smart Mode 00427^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ THERAPYDISABLEDBYSMARTMODE^MDT 00428^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ THERAPYDISABLEDBYSMARTMODE^MDT
127 Connectivity Guide Paceart Integration 25 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Disabled By Smart Mode Disabled By Smart Mode 00429^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ THERAPYDISABLEDBYSMARTMODE^MDT Disabled By Smart Mode 00430^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ THERAPYDISABLEDBYSMARTMODE^MDT Disabled By Smart Mode 0043^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ THERAPYDISABLEDBYSMARTMODE^MDT Disabled By Smart Mode 00432^MDT_PROG_TACHY_ZONE_THERAPIES_0_ATPTHERAPY_ THERAPYDISABLEDBYSMARTMODE^MDT Disabled By Smart Mode 00433^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ THERAPYDISABLEDBYSMARTMODE^MDT Disabled By Smart Mode 00434^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ THERAPYDISABLEDBYSMARTMODE^MDT Disabled By Smart Mode 00435^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ THERAPYDISABLEDBYSMARTMODE^MDT Disabled By Smart Mode 00436^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ THERAPYDISABLEDBYSMARTMODE^MDT Disabled By Smart Mode 00437^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ THERAPYDISABLEDBYSMARTMODE^MDT Disabled By Smart Mode 00438^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ THERAPYDISABLEDBYSMARTMODE^MDT 00439^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ THERAPYDISABLEDBYSMARTMODE^MDT
128 26 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Disabled By Smart Mode Disabled By Smart Mode 00440^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ THERAPYDISABLEDBYSMARTMODE^MDT Disabled By Smart Mode 0044^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ THERAPYDISABLEDBYSMARTMODE^MDT Disabled By Smart Mode 00442^MDT_PROG_TACHY_ZONE_THERAPIES_20_ATPTHERAPY_ THERAPYDISABLEDBYSMARTMODE^MDT Burst Cycle Length Fixed 00443^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ BURCYCLELENGTH_FIED^MDT Burst Cycle Length Fixed 00444^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ BURCYCLELENGTH_FIED^MDT Burst Cycle Length Fixed 00445^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ BURCYCLELENGTH_FIED^MDT Burst Cycle Length Fixed 00446^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ BURCYCLELENGTH_FIED^MDT Burst Cycle Length Fixed 00447^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ BURCYCLELENGTH_FIED^MDT Burst Cycle Length Fixed 00448^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ BURCYCLELENGTH_FIED^MDT Burst Cycle Length Fixed 00449^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ BURCYCLELENGTH_FIED^MDT Burst Cycle Length Fixed 00450^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ BURCYCLELENGTH_FIED^MDT
129 Connectivity Guide Paceart Integration 27 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Burst Cycle Length Fixed 0045^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ BURCYCLELENGTH_FIED^MDT Burst Cycle Length Fixed 00452^MDT_PROG_TACHY_ZONE_THERAPIES_0_ATPTHERAPY_ BURCYCLELENGTH_FIED^MDT Burst Cycle Length Fixed 00453^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ BURCYCLELENGTH_FIED^MDT Burst Cycle Length Fixed 00454^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ BURCYCLELENGTH_FIED^MDT Burst Cycle Length Fixed 00455^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ BURCYCLELENGTH_FIED^MDT Burst Cycle Length Fixed 00456^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ BURCYCLELENGTH_FIED^MDT Burst Cycle Length Fixed 00457^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ BURCYCLELENGTH_FIED^MDT Burst Cycle Length Fixed 00458^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ BURCYCLELENGTH_FIED^MDT Burst Cycle Length Fixed 00459^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ BURCYCLELENGTH_FIED^MDT Burst Cycle Length Fixed 00460^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ BURCYCLELENGTH_FIED^MDT Burst Cycle Length Fixed 0046^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ BURCYCLELENGTH_FIED^MDT 00462^MDT_PROG_TACHY_ZONE_THERAPIES_20_ATPTHERAPY_ BURCYCLELENGTH_FIED^MDT
130 28 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Burst Cycle Length Fixed Burst Cycle Length Percent 00463^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ BURCYCLELENGTH_PERCENT^MDT %^percent^mdc Burst Cycle Length Percent 00464^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ BURCYCLELENGTH_PERCENT^MDT %^percent^mdc Burst Cycle Length Percent 00465^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ BURCYCLELENGTH_PERCENT^MDT %^percent^mdc Burst Cycle Length Percent 00466^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ BURCYCLELENGTH_PERCENT^MDT %^percent^mdc Burst Cycle Length Percent 00467^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ BURCYCLELENGTH_PERCENT^MDT %^percent^mdc Burst Cycle Length Percent 00468^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ BURCYCLELENGTH_PERCENT^MDT %^percent^mdc Burst Cycle Length Percent 00469^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ BURCYCLELENGTH_PERCENT^MDT %^percent^mdc Burst Cycle Length Percent 00470^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ BURCYCLELENGTH_PERCENT^MDT %^percent^mdc Burst Cycle Length Percent 0047^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ BURCYCLELENGTH_PERCENT^MDT %^percent^mdc 00472^MDT_PROG_TACHY_ZONE_THERAPIES_0_ATPTHERAPY_ BURCYCLELENGTH_PERCENT^MDT %^percent^mdc
131 Connectivity Guide Paceart Integration 29 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Burst Cycle Length Percent Burst Cycle Length Percent 00473^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ BURCYCLELENGTH_PERCENT^MDT %^percent^mdc Burst Cycle Length Percent 00474^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ BURCYCLELENGTH_PERCENT^MDT %^percent^mdc Burst Cycle Length Percent 00475^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ BURCYCLELENGTH_PERCENT^MDT %^percent^mdc Burst Cycle Length Percent 00476^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ BURCYCLELENGTH_PERCENT^MDT %^percent^mdc Burst Cycle Length Percent 00477^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ BURCYCLELENGTH_PERCENT^MDT %^percent^mdc Burst Cycle Length Percent 00478^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ BURCYCLELENGTH_PERCENT^MDT %^percent^mdc Burst Cycle Length Percent 00479^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ BURCYCLELENGTH_PERCENT^MDT %^percent^mdc Burst Cycle Length Percent 00480^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ BURCYCLELENGTH_PERCENT^MDT %^percent^mdc Burst Cycle Length Percent 0048^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ BURCYCLELENGTH_PERCENT^MDT %^percent^mdc
132 30 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Burst Cycle Length Percent 00482^MDT_PROG_TACHY_ZONE_THERAPIES_20_ATPTHERAPY_ BURCYCLELENGTH_PERCENT^MDT %^percent^mdc SS2 Ramp Percent 00483^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ SS2RAMPPERCENT^MDT %^percent^mdc SS2 Ramp Percent 00484^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ SS2RAMPPERCENT^MDT %^percent^mdc SS2 Ramp Percent 00485^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ SS2RAMPPERCENT^MDT %^percent^mdc SS2 Ramp Percent 00486^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ SS2RAMPPERCENT^MDT %^percent^mdc SS2 Ramp Percent 00487^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ SS2RAMPPERCENT^MDT %^percent^mdc SS2 Ramp Percent 00488^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ SS2RAMPPERCENT^MDT %^percent^mdc SS2 Ramp Percent 00489^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ SS2RAMPPERCENT^MDT %^percent^mdc SS2 Ramp Percent 00490^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ SS2RAMPPERCENT^MDT %^percent^mdc SS2 Ramp Percent 0049^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ SS2RAMPPERCENT^MDT %^percent^mdc SS2 Ramp Percent 00492^MDT_PROG_TACHY_ZONE_THERAPIES_0_ATPTHERAPY_ SS2RAMPPERCENT^MDT %^percent^mdc
133 Connectivity Guide Paceart Integration 3 Paceart parameter type OB-2 OB-3 OB-4 OB-6 SS2 Ramp Percent 00493^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ SS2RAMPPERCENT^MDT %^percent^mdc SS2 Ramp Percent 00494^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ SS2RAMPPERCENT^MDT %^percent^mdc SS2 Ramp Percent 00495^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ SS2RAMPPERCENT^MDT %^percent^mdc SS2 Ramp Percent 00496^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ SS2RAMPPERCENT^MDT %^percent^mdc SS2 Ramp Percent 00497^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ SS2RAMPPERCENT^MDT %^percent^mdc SS2 Ramp Percent 00498^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ SS2RAMPPERCENT^MDT %^percent^mdc SS2 Ramp Percent 00499^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ SS2RAMPPERCENT^MDT %^percent^mdc SS2 Ramp Percent 00500^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ SS2RAMPPERCENT^MDT %^percent^mdc SS2 Ramp Percent 0050^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ SS2RAMPPERCENT^MDT %^percent^mdc SS2 Ramp Percent 00502^MDT_PROG_TACHY_ZONE_THERAPIES_20_ATPTHERAPY_ SS2RAMPPERCENT^MDT %^percent^mdc S2SN Ramp Percent 00503^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ S2SNRAMPPERCENT^MDT %^percent^mdc 00504^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ S2SNRAMPPERCENT^MDT %^percent^mdc
134 32 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 S2SN Ramp Percent S2SN Ramp Percent 00505^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ S2SNRAMPPERCENT^MDT %^percent^mdc S2SN Ramp Percent 00506^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ S2SNRAMPPERCENT^MDT %^percent^mdc S2SN Ramp Percent 00507^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ S2SNRAMPPERCENT^MDT %^percent^mdc S2SN Ramp Percent 00508^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ S2SNRAMPPERCENT^MDT %^percent^mdc S2SN Ramp Percent 00509^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ S2SNRAMPPERCENT^MDT %^percent^mdc S2SN Ramp Percent 0050^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ S2SNRAMPPERCENT^MDT %^percent^mdc S2SN Ramp Percent 005^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ S2SNRAMPPERCENT^MDT %^percent^mdc S2SN Ramp Percent 0052^MDT_PROG_TACHY_ZONE_THERAPIES_0_ATPTHERAPY_ S2SNRAMPPERCENT^MDT %^percent^mdc S2SN Ramp Percent 0053^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ S2SNRAMPPERCENT^MDT %^percent^mdc S2SN Ramp Percent 0054^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ S2SNRAMPPERCENT^MDT %^percent^mdc 0055^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ S2SNRAMPPERCENT^MDT %^percent^mdc
135 Connectivity Guide Paceart Integration 33 Paceart parameter type OB-2 OB-3 OB-4 OB-6 S2SN Ramp Percent S2SN Ramp Percent 0056^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ S2SNRAMPPERCENT^MDT %^percent^mdc S2SN Ramp Percent 0057^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ S2SNRAMPPERCENT^MDT %^percent^mdc S2SN Ramp Percent 0058^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ S2SNRAMPPERCENT^MDT %^percent^mdc S2SN Ramp Percent 0059^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ S2SNRAMPPERCENT^MDT %^percent^mdc S2SN Ramp Percent 00520^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ S2SNRAMPPERCENT^MDT %^percent^mdc S2SN Ramp Percent 0052^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ S2SNRAMPPERCENT^MDT %^percent^mdc S2SN Ramp Percent 00522^MDT_PROG_TACHY_ZONE_THERAPIES_20_ATPTHERAPY_ S2SNRAMPPERCENT^MDT %^percent^mdc Scan Sequence 00523^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ SCANSEQUENCE^MDT Scan Sequence 00524^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ SCANSEQUENCE^MDT Scan Sequence 00525^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ SCANSEQUENCE^MDT Scan Sequence 00526^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ SCANSEQUENCE^MDT
136 34 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Scan Sequence 00527^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ SCANSEQUENCE^MDT Scan Sequence 00528^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ SCANSEQUENCE^MDT Scan Sequence 00529^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ SCANSEQUENCE^MDT Scan Sequence 00530^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ SCANSEQUENCE^MDT Scan Sequence 0053^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ SCANSEQUENCE^MDT Scan Sequence 00532^MDT_PROG_TACHY_ZONE_THERAPIES_0_ATPTHERAPY_ SCANSEQUENCE^MDT Scan Sequence 00533^MDT_PROG_TACHY_ZONE_THERAPIES ATPTHERAPY_ SCANSEQUENCE^MDT Scan Sequence 00534^MDT_PROG_TACHY_ZONE_THERAPIES_2_ATPTHERAPY_ SCANSEQUENCE^MDT Scan Sequence 00535^MDT_PROG_TACHY_ZONE_THERAPIES_3_ATPTHERAPY_ SCANSEQUENCE^MDT Scan Sequence 00536^MDT_PROG_TACHY_ZONE_THERAPIES_4_ATPTHERAPY_ SCANSEQUENCE^MDT Scan Sequence 00537^MDT_PROG_TACHY_ZONE_THERAPIES_5_ATPTHERAPY_ SCANSEQUENCE^MDT 00538^MDT_PROG_TACHY_ZONE_THERAPIES_6_ATPTHERAPY_ SCANSEQUENCE^MDT
137 Connectivity Guide Paceart Integration 35 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Scan Sequence Scan Sequence 00539^MDT_PROG_TACHY_ZONE_THERAPIES_7_ATPTHERAPY_ SCANSEQUENCE^MDT Scan Sequence 00540^MDT_PROG_TACHY_ZONE_THERAPIES_8_ATPTHERAPY_ SCANSEQUENCE^MDT Scan Sequence 0054^MDT_PROG_TACHY_ZONE_THERAPIES_9_ATPTHERAPY_ SCANSEQUENCE^MDT Scan Sequence 00542^MDT_PROG_TACHY_ZONE_THERAPIES_20_ATPTHERAPY_ SCANSEQUENCE^MDT Energy 0063^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ ENERGY^MDT J^joules^MDC Energy 0064^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ ENERGY^MDT J^joules^MDC Energy 0065^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ ENERGY^MDT J^joules^MDC Energy 0066^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ ENERGY^MDT J^joules^MDC Energy 0067^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ ENERGY^MDT J^joules^MDC Energy 0068^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ ENERGY^MDT J^joules^MDC 0069^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ ENERGY^MDT J^joules^MDC
138 OB-6 OB-4 OB-3 OB-2 type Paceart parameter Energy J^joules^MDC 0070^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ ENERGY^MDT Energy J^joules^MDC 007^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ ENERGY^MDT Energy J^joules^MDC 0072^MDT_PROG_TACHY_ZONE_THERAPIES_0_SHOCKTHERAPY_ ENERGY^MDT Energy J^joules^MDC 0073^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ ENERGY^MDT Energy J^joules^MDC 0074^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ ENERGY^MDT Energy J^joules^MDC 0075^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ ENERGY^MDT Energy J^joules^MDC 0076^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ ENERGY^MDT Energy J^joules^MDC 0077^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ ENERGY^MDT Energy J^joules^MDC 0078^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ ENERGY^MDT Energy J^joules^MDC 0079^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ ENERGY^MDT Energy J^joules^MDC 0080^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ ENERGY^MDT Energy 36 Connectivity Guide Paceart Integration
139 OB-6 OB-4 OB-3 OB-2 type Paceart parameter J^joules^MDC 008^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ ENERGY^MDT Energy J^joules^MDC 0082^MDT_PROG_TACHY_ZONE_THERAPIES_20_SHOCKTHERAPY_ ENERGY^MDT Energy V^volts^MDC 00543^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ VOLTAGE^MDT Voltage V^volts^MDC 00544^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ VOLTAGE^MDT Voltage V^volts^MDC 00545^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ VOLTAGE^MDT Voltage V^volts^MDC 00546^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ VOLTAGE^MDT Voltage V^volts^MDC 00547^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ VOLTAGE^MDT Voltage V^volts^MDC 00548^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ VOLTAGE^MDT Voltage V^volts^MDC 00549^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ VOLTAGE^MDT Voltage V^volts^MDC 00550^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ VOLTAGE^MDT Voltage V^volts^MDC 0055^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ VOLTAGE^MDT Voltage V^volts^MDC 00552^MDT_PROG_TACHY_ZONE_THERAPIES_0_SHOCKTHERAPY_ VOLTAGE^MDT Connectivity Guide Paceart Integration 37
140 OB-6 OB-4 OB-3 OB-2 type Paceart parameter Voltage V^volts^MDC 00553^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ VOLTAGE^MDT Voltage V^volts^MDC 00554^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ VOLTAGE^MDT Voltage V^volts^MDC 00555^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ VOLTAGE^MDT Voltage V^volts^MDC 00556^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ VOLTAGE^MDT Voltage V^volts^MDC 00557^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ VOLTAGE^MDT Voltage V^volts^MDC 00558^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ VOLTAGE^MDT Voltage V^volts^MDC 00559^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ VOLTAGE^MDT Voltage V^volts^MDC 00560^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ VOLTAGE^MDT Voltage V^volts^MDC 0056^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ VOLTAGE^MDT Voltage V^volts^MDC 00562^MDT_PROG_TACHY_ZONE_THERAPIES_20_SHOCKTHERAPY_ VOLTAGE^MDT Voltage 00563^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ WAVEFORM^MDT 38 Connectivity Guide Paceart Integration
141 OB-6 OB-4 OB-3 OB-2 type Paceart parameter Waveform 00564^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ WAVEFORM^MDT Waveform 00565^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ WAVEFORM^MDT Waveform 00566^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ WAVEFORM^MDT Waveform 00567^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ WAVEFORM^MDT Waveform 00568^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ WAVEFORM^MDT Waveform 00569^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ WAVEFORM^MDT Waveform 00570^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ WAVEFORM^MDT Waveform 0057^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ WAVEFORM^MDT Waveform 00572^MDT_PROG_TACHY_ZONE_THERAPIES_0_SHOCKTHERAPY_ WAVEFORM^MDT Waveform 00573^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ WAVEFORM^MDT Waveform 00574^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ WAVEFORM^MDT Waveform Connectivity Guide Paceart Integration 39
142 OB-6 OB-4 OB-3 OB-2 type Paceart parameter 00575^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ WAVEFORM^MDT Waveform 00576^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ WAVEFORM^MDT Waveform 00577^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ WAVEFORM^MDT Waveform 00578^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ WAVEFORM^MDT Waveform 00579^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ WAVEFORM^MDT Waveform 00580^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ WAVEFORM^MDT Waveform 0058^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ WAVEFORM^MDT Waveform 00582^MDT_PROG_TACHY_ZONE_THERAPIES_20_SHOCKTHERAPY_ WAVEFORM^MDT Waveform 00583^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_^MDT 00584^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_^MDT 00585^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_^MDT 40 Connectivity Guide Paceart Integration
143 OB-6 OB-4 OB-3 OB-2 type Paceart parameter 00586^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_^MDT 00587^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_^MDT 00588^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_^MDT 00589^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_^MDT 00590^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_^MDT 0059^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_^MDT 00592^MDT_PROG_TACHY_ZONE_THERAPIES_0_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_^MDT 00593^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_^MDT 00594^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_^MDT 00595^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_^MDT Connectivity Guide Paceart Integration 4
144 OB-6 OB-4 OB-3 OB-2 type Paceart parameter 00596^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_^MDT 00597^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_^MDT 00598^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_^MDT 00599^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_^MDT 00600^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_^MDT 0060^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_^MDT 00602^MDT_PROG_TACHY_ZONE_THERAPIES_20_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_^MDT 00603^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_^MDT 00604^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_^MDT 00605^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_^MDT 42 Connectivity Guide Paceart Integration
145 OB-6 OB-4 OB-3 OB-2 type Paceart parameter 00606^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_^MDT 00607^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_^MDT 00608^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_^MDT 00609^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_^MDT 0060^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_^MDT 006^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_^MDT 0062^MDT_PROG_TACHY_ZONE_THERAPIES_0_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_^MDT 0063^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_^MDT 0064^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_^MDT 0065^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_^MDT Connectivity Guide Paceart Integration 43
146 OB-6 OB-4 OB-3 OB-2 type Paceart parameter 0066^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_^MDT 0067^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_^MDT 0068^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_^MDT 0069^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_^MDT 00620^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_^MDT 0062^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_^MDT 00622^MDT_PROG_TACHY_ZONE_THERAPIES_20_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_^MDT 00623^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_2^MDT 00624^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_2^MDT 00625^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_2^MDT 44 Connectivity Guide Paceart Integration
147 OB-6 OB-4 OB-3 OB-2 type Paceart parameter 00626^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_2^MDT 00627^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_2^MDT 00628^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_2^MDT 00629^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_2^MDT 00630^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_2^MDT 0063^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_2^MDT 00632^MDT_PROG_TACHY_ZONE_THERAPIES_0_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_2^MDT 00633^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_2^MDT 00634^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_2^MDT 00635^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_2^MDT Connectivity Guide Paceart Integration 45
148 OB-6 OB-4 OB-3 OB-2 type Paceart parameter 00636^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_2^MDT 00637^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_2^MDT 00638^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_2^MDT 00639^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_2^MDT 00640^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_2^MDT 0064^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_2^MDT 00642^MDT_PROG_TACHY_ZONE_THERAPIES_20_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_2^MDT 00643^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_2^MDT 00644^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_2^MDT 00645^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_2^MDT 46 Connectivity Guide Paceart Integration
149 OB-6 OB-4 OB-3 OB-2 type Paceart parameter 00646^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_2^MDT 00647^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_2^MDT 00648^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_2^MDT 00649^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_2^MDT 00650^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_2^MDT 0065^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_2^MDT 00652^MDT_PROG_TACHY_ZONE_THERAPIES_0_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_2^MDT 00653^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_2^MDT 00654^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_2^MDT 00655^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_2^MDT Connectivity Guide Paceart Integration 47
150 OB-6 OB-4 OB-3 OB-2 type Paceart parameter 00656^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_2^MDT 00657^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_2^MDT 00658^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_2^MDT 00659^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_2^MDT 00660^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_2^MDT 0066^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_2^MDT 00662^MDT_PROG_TACHY_ZONE_THERAPIES_20_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_2^MDT 00663^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_3^MDT 00664^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_3^MDT 00665^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_3^MDT 48 Connectivity Guide Paceart Integration
151 OB-6 OB-4 OB-3 OB-2 type Paceart parameter 00666^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_3^MDT 00667^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_3^MDT 00668^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_3^MDT 00669^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_3^MDT 00670^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_3^MDT 0067^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_3^MDT 00672^MDT_PROG_TACHY_ZONE_THERAPIES_0_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_3^MDT 00673^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_3^MDT 00674^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_3^MDT 00675^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_3^MDT Connectivity Guide Paceart Integration 49
152 OB-6 OB-4 OB-3 OB-2 type Paceart parameter 00676^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_3^MDT 00677^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_3^MDT 00678^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_3^MDT 00679^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_3^MDT 00680^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_3^MDT 0068^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_3^MDT 00682^MDT_PROG_TACHY_ZONE_THERAPIES_20_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_LOCATION_3^MDT 00683^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_3^MDT 00684^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_3^MDT 00685^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_3^MDT 50 Connectivity Guide Paceart Integration
153 OB-6 OB-4 OB-3 OB-2 type Paceart parameter 00686^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_3^MDT 00687^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_3^MDT 00688^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_3^MDT 00689^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_3^MDT 00690^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_3^MDT 0069^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_3^MDT 00692^MDT_PROG_TACHY_ZONE_THERAPIES_0_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_3^MDT 00693^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_3^MDT 00694^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_3^MDT 00695^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_3^MDT Connectivity Guide Paceart Integration 5
154 OB-6 OB-4 OB-3 OB-2 type Paceart parameter 00696^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_3^MDT 00697^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_3^MDT 00698^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_3^MDT 00699^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_3^MDT 00700^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_3^MDT 0070^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_3^MDT 00702^MDT_PROG_TACHY_ZONE_THERAPIES_20_SHOCKTHERAPY_ PATHWAY_POLE_ANODE_ELECTRODE_3^MDT 00703^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_^MDT 00704^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_^MDT 00705^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_^MDT 52 Connectivity Guide Paceart Integration
155 OB-6 OB-4 OB-3 OB-2 type Paceart parameter 00706^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_^MDT 00707^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_^MDT 00708^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_^MDT 00709^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_^MDT 0070^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_^MDT 007^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_^MDT 0072^MDT_PROG_TACHY_ZONE_THERAPIES_0_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_^MDT 0073^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_^MDT 0074^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_^MDT 0075^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_^MDT Connectivity Guide Paceart Integration 53
156 OB-6 OB-4 OB-3 OB-2 type Paceart parameter 0076^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_^MDT 0077^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_^MDT 0078^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_^MDT 0079^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_^MDT 00720^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_^MDT 0072^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_^MDT 00722^MDT_PROG_TACHY_ZONE_THERAPIES_20_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_^MDT 00723^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_^MDT 00724^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_^MDT 00725^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_^MDT 54 Connectivity Guide Paceart Integration
157 OB-6 OB-4 OB-3 OB-2 type Paceart parameter 00726^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_^MDT 00727^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_^MDT 00728^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_^MDT 00729^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_^MDT 00730^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_^MDT 0073^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_^MDT 00732^MDT_PROG_TACHY_ZONE_THERAPIES_0_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_^MDT 00733^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_^MDT 00734^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_^MDT 00735^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_^MDT Connectivity Guide Paceart Integration 55
158 OB-6 OB-4 OB-3 OB-2 type Paceart parameter 00736^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_^MDT 00737^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_^MDT 00738^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_^MDT 00739^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_^MDT 00740^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_^MDT 0074^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_^MDT 00742^MDT_PROG_TACHY_ZONE_THERAPIES_20_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_^MDT 00743^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_2^MDT 00744^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_2^MDT 00745^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_2^MDT 56 Connectivity Guide Paceart Integration
159 OB-6 OB-4 OB-3 OB-2 type Paceart parameter 00746^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_2^MDT 00747^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_2^MDT 00748^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_2^MDT 00749^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_2^MDT 00750^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_2^MDT 0075^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_2^MDT 00752^MDT_PROG_TACHY_ZONE_THERAPIES_0_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_2^MDT 00753^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_2^MDT 00754^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_2^MDT 00755^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_2^MDT Connectivity Guide Paceart Integration 57
160 OB-6 OB-4 OB-3 OB-2 type Paceart parameter 00756^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_2^MDT 00757^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_2^MDT 00758^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_2^MDT 00759^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_2^MDT 00760^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_2^MDT 0076^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_2^MDT 00762^MDT_PROG_TACHY_ZONE_THERAPIES_20_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_2^MDT 00763^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_2^MDT 00764^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_2^MDT 00765^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_2^MDT 58 Connectivity Guide Paceart Integration
161 OB-6 OB-4 OB-3 OB-2 type Paceart parameter 00766^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_2^MDT 00767^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_2^MDT 00768^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_2^MDT 00769^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_2^MDT 00770^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_2^MDT 0077^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_2^MDT 00772^MDT_PROG_TACHY_ZONE_THERAPIES_0_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_2^MDT 00773^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_2^MDT 00774^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_2^MDT 00775^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_2^MDT Connectivity Guide Paceart Integration 59
162 OB-6 OB-4 OB-3 OB-2 type Paceart parameter 00776^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_2^MDT 00777^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_2^MDT 00778^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_2^MDT 00779^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_2^MDT 00780^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_2^MDT 0078^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_2^MDT 00782^MDT_PROG_TACHY_ZONE_THERAPIES_20_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_2^MDT 00783^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_3^MDT 00784^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_3^MDT 00785^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_3^MDT 60 Connectivity Guide Paceart Integration
163 OB-6 OB-4 OB-3 OB-2 type Paceart parameter 00786^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_3^MDT 00787^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_3^MDT 00788^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_3^MDT 00789^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_3^MDT 00790^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_3^MDT 0079^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_3^MDT 00792^MDT_PROG_TACHY_ZONE_THERAPIES_0_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_3^MDT 00793^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_3^MDT 00794^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_3^MDT 00795^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_3^MDT Connectivity Guide Paceart Integration 6
164 OB-6 OB-4 OB-3 OB-2 type Paceart parameter 00796^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_3^MDT 00797^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_3^MDT 00798^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_3^MDT 00799^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_3^MDT 00800^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_3^MDT 0080^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_3^MDT 00802^MDT_PROG_TACHY_ZONE_THERAPIES_20_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_LOCATION_3^MDT 00803^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_3^MDT 00804^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_3^MDT 00805^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_3^MDT 62 Connectivity Guide Paceart Integration
165 OB-6 OB-4 OB-3 OB-2 type Paceart parameter 00806^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_3^MDT 00807^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_3^MDT 00808^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_3^MDT 00809^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_3^MDT 0080^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_3^MDT 008^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_3^MDT 0082^MDT_PROG_TACHY_ZONE_THERAPIES_0_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_3^MDT 0083^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_3^MDT 0084^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_3^MDT 0085^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_3^MDT Connectivity Guide Paceart Integration 63
166 OB-6 OB-4 OB-3 OB-2 type Paceart parameter 0086^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_3^MDT 0087^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_3^MDT 0088^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_3^MDT 0089^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_3^MDT 00820^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_3^MDT 0082^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_3^MDT 00822^MDT_PROG_TACHY_ZONE_THERAPIES_20_SHOCKTHERAPY_ PATHWAY_POLE_CATHODE_ELECTRODE_3^MDT 00823^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ CARDIOVERSIONDELAY^MDT Cardioversion Delay 00824^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ CARDIOVERSIONDELAY^MDT Cardioversion Delay 00825^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ CARDIOVERSIONDELAY^MDT Cardioversion Delay 64 Connectivity Guide Paceart Integration
167 OB-6 OB-4 OB-3 OB-2 type Paceart parameter 00826^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ CARDIOVERSIONDELAY^MDT Cardioversion Delay 00827^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ CARDIOVERSIONDELAY^MDT Cardioversion Delay 00828^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ CARDIOVERSIONDELAY^MDT Cardioversion Delay 00829^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ CARDIOVERSIONDELAY^MDT Cardioversion Delay 00830^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ CARDIOVERSIONDELAY^MDT Cardioversion Delay 0083^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ CARDIOVERSIONDELAY^MDT Cardioversion Delay 00832^MDT_PROG_TACHY_ZONE_THERAPIES_0_SHOCKTHERAPY_ CARDIOVERSIONDELAY^MDT Cardioversion Delay 00833^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ CARDIOVERSIONDELAY^MDT Cardioversion Delay 00834^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ CARDIOVERSIONDELAY^MDT Cardioversion Delay 00835^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ CARDIOVERSIONDELAY^MDT Cardioversion Delay Connectivity Guide Paceart Integration 65
168 OB-6 OB-4 OB-3 OB-2 type Paceart parameter 00836^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ CARDIOVERSIONDELAY^MDT Cardioversion Delay 00837^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ CARDIOVERSIONDELAY^MDT Cardioversion Delay 00838^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ CARDIOVERSIONDELAY^MDT Cardioversion Delay 00839^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ CARDIOVERSIONDELAY^MDT Cardioversion Delay 00840^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ CARDIOVERSIONDELAY^MDT Cardioversion Delay 0084^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ CARDIOVERSIONDELAY^MDT Cardioversion Delay 00842^MDT_PROG_TACHY_ZONE_THERAPIES_20_SHOCKTHERAPY_ CARDIOVERSIONDELAY^MDT Cardioversion Delay 00843^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ PULSEWIDTHNEGATIVE^MDT Pulse Width Negative 00844^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ PULSEWIDTHNEGATIVE^MDT Pulse Width Negative 00845^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ PULSEWIDTHNEGATIVE^MDT Pulse Width Negative 66 Connectivity Guide Paceart Integration
169 Connectivity Guide Paceart Integration 67 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Pulse Width Negative 00846^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ PULSEWIDTHNEGATIVE^MDT Pulse Width Negative 00847^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ PULSEWIDTHNEGATIVE^MDT Pulse Width Negative 00848^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ PULSEWIDTHNEGATIVE^MDT Pulse Width Negative 00849^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ PULSEWIDTHNEGATIVE^MDT Pulse Width Negative 00850^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ PULSEWIDTHNEGATIVE^MDT Pulse Width Negative 0085^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ PULSEWIDTHNEGATIVE^MDT Pulse Width Negative 00852^MDT_PROG_TACHY_ZONE_THERAPIES_0_SHOCKTHERAPY_ PULSEWIDTHNEGATIVE^MDT Pulse Width Negative 00853^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ PULSEWIDTHNEGATIVE^MDT Pulse Width Negative 00854^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ PULSEWIDTHNEGATIVE^MDT Pulse Width Negative 00855^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ PULSEWIDTHNEGATIVE^MDT
170 68 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Pulse Width Negative 00856^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ PULSEWIDTHNEGATIVE^MDT Pulse Width Negative 00857^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ PULSEWIDTHNEGATIVE^MDT Pulse Width Negative 00858^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ PULSEWIDTHNEGATIVE^MDT Pulse Width Negative 00859^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ PULSEWIDTHNEGATIVE^MDT Pulse Width Negative 00860^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ PULSEWIDTHNEGATIVE^MDT Pulse Width Negative 0086^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ PULSEWIDTHNEGATIVE^MDT Pulse Width Negative 00862^MDT_PROG_TACHY_ZONE_THERAPIES_20_SHOCKTHERAPY_ PULSEWIDTHNEGATIVE^MDT Pulse Width Positive 00863^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ PULSEWIDTHPOSITIVE^MDT Pulse Width Positive 00864^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ PULSEWIDTHPOSITIVE^MDT Pulse Width Positive 00865^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ PULSEWIDTHPOSITIVE^MDT 00866^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ PULSEWIDTHPOSITIVE^MDT
171 Connectivity Guide Paceart Integration 69 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Pulse Width Positive Pulse Width Positive 00867^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ PULSEWIDTHPOSITIVE^MDT Pulse Width Positive 00868^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ PULSEWIDTHPOSITIVE^MDT Pulse Width Positive 00869^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ PULSEWIDTHPOSITIVE^MDT Pulse Width Positive 00870^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ PULSEWIDTHPOSITIVE^MDT Pulse Width Positive 0087^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ PULSEWIDTHPOSITIVE^MDT Pulse Width Positive 00872^MDT_PROG_TACHY_ZONE_THERAPIES_0_SHOCKTHERAPY_ PULSEWIDTHPOSITIVE^MDT Pulse Width Positive 00873^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ PULSEWIDTHPOSITIVE^MDT Pulse Width Positive 00874^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ PULSEWIDTHPOSITIVE^MDT Pulse Width Positive 00875^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ PULSEWIDTHPOSITIVE^MDT Pulse Width Positive 00876^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ PULSEWIDTHPOSITIVE^MDT 00877^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ PULSEWIDTHPOSITIVE^MDT
172 70 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Pulse Width Positive Pulse Width Positive 00878^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ PULSEWIDTHPOSITIVE^MDT Pulse Width Positive 00879^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ PULSEWIDTHPOSITIVE^MDT Pulse Width Positive 00880^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ PULSEWIDTHPOSITIVE^MDT Pulse Width Positive 0088^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ PULSEWIDTHPOSITIVE^MDT Pulse Width Positive 00882^MDT_PROG_TACHY_ZONE_THERAPIES_20_SHOCKTHERAPY_ PULSEWIDTHPOSITIVE^MDT Tilt Negative 00883^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ TILTNEGATIVE^MDT %^percent^mdc Tilt Negative 00884^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ TILTNEGATIVE^MDT %^percent^mdc Tilt Negative 00885^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ TILTNEGATIVE^MDT %^percent^mdc Tilt Negative 00886^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ TILTNEGATIVE^MDT %^percent^mdc Tilt Negative 00887^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ TILTNEGATIVE^MDT %^percent^mdc Tilt Negative 00887^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ TILTNEGATIVE^MDT
173 Connectivity Guide Paceart Integration 7 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Tilt Negative 00888^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ TILTNEGATIVE^MDT %^percent^mdc Tilt Negative 00889^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ TILTNEGATIVE^MDT %^percent^mdc Tilt Negative 00890^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ TILTNEGATIVE^MDT %^percent^mdc Tilt Negative 0089^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ TILTNEGATIVE^MDT %^percent^mdc Tilt Negative 00892^MDT_PROG_TACHY_ZONE_THERAPIES_0_SHOCKTHERAPY_ TILTNEGATIVE^MDT %^percent^mdc Tilt Negative 00893^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ TILTNEGATIVE^MDT %^percent^mdc Tilt Negative 00894^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ TILTNEGATIVE^MDT %^percent^mdc Tilt Negative 00895^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ TILTNEGATIVE^MDT %^percent^mdc Tilt Negative 00896^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ TILTNEGATIVE^MDT %^percent^mdc Tilt Negative 00897^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ TILTNEGATIVE^MDT %^percent^mdc Tilt Negative 00898^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ TILTNEGATIVE^MDT %^percent^mdc 00899^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ TILTNEGATIVE^MDT %^percent^mdc
174 72 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Tilt Negative Tilt Negative 00900^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ TILTNEGATIVE^MDT %^percent^mdc Tilt Negative 0090^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ TILTNEGATIVE^MDT %^percent^mdc Tilt Negative 00902^MDT_PROG_TACHY_ZONE_THERAPIES_20_SHOCKTHERAPY_ TILTNEGATIVE^MDT %^percent^mdc Tilt Positive 00903^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ TILTPOSITIVE^MDT %^percent^mdc Tilt Positive 00904^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ TILTPOSITIVE^MDT %^percent^mdc Tilt Positive 00905^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ TILTPOSITIVE^MDT %^percent^mdc Tilt Positive 00906^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ TILTPOSITIVE^MDT %^percent^mdc Tilt Positive 00907^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ TILTPOSITIVE^MDT %^percent^mdc Tilt Positive 00908^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ TILTPOSITIVE^MDT %^percent^mdc Tilt Positive 00909^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ TILTPOSITIVE^MDT %^percent^mdc 0090^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ TILTPOSITIVE^MDT %^percent^mdc
175 Connectivity Guide Paceart Integration 73 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Tilt Positive Tilt Positive 009^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ TILTPOSITIVE^MDT %^percent^mdc Tilt Positive 0092^MDT_PROG_TACHY_ZONE_THERAPIES_0_SHOCKTHERAPY_ TILTPOSITIVE^MDT %^percent^mdc Tilt Positive 0093^MDT_PROG_TACHY_ZONE_THERAPIES SHOCKTHERAPY_ TILTPOSITIVE^MDT %^percent^mdc Tilt Positive 0094^MDT_PROG_TACHY_ZONE_THERAPIES_2_SHOCKTHERAPY_ TILTPOSITIVE^MDT %^percent^mdc Tilt Positive 0095^MDT_PROG_TACHY_ZONE_THERAPIES_3_SHOCKTHERAPY_ TILTPOSITIVE^MDT %^percent^mdc Tilt Positive 0096^MDT_PROG_TACHY_ZONE_THERAPIES_4_SHOCKTHERAPY_ TILTPOSITIVE^MDT %^percent^mdc Tilt Positive 0097^MDT_PROG_TACHY_ZONE_THERAPIES_5_SHOCKTHERAPY_ TILTPOSITIVE^MDT %^percent^mdc Tilt Positive 0098^MDT_PROG_TACHY_ZONE_THERAPIES_6_SHOCKTHERAPY_ TILTPOSITIVE^MDT %^percent^mdc Tilt Positive 0099^MDT_PROG_TACHY_ZONE_THERAPIES_7_SHOCKTHERAPY_ TILTPOSITIVE^MDT %^percent^mdc Tilt Positive 00920^MDT_PROG_TACHY_ZONE_THERAPIES_8_SHOCKTHERAPY_ TILTPOSITIVE^MDT %^percent^mdc Tilt Positive 0092^MDT_PROG_TACHY_ZONE_THERAPIES_9_SHOCKTHERAPY_ TILTPOSITIVE^MDT %^percent^mdc
176 74 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Tilt Positive 00922^MDT_PROG_TACHY_ZONE_THERAPIES_20_SHOCKTHERAPY_ TILTPOSITIVE^MDT %^percent^mdc Zone Committed 00923^MDT_PROG_TACHY_ZONE_SHAREDSETTINGS_ COMMITTEDSHOCK^MDT Outbound OB Statistics Message Segments Paceart parameter type OB-2 OB-3 OB-4 OB-6 Measured Device Battery Timestamp DTM 7226^MDC_IDC_MSMT_ BATTERY_DTM^MDC Measured Device Battery Status 72280^MDC_IDC_MSMT_ BATTERY_ATUS^MDC Measured Device Battery Status RRT Trigger 72600^MDC_IDC_MSMT_ BATTERY_RRT_TRIGGER^MDC Measured Device Battery Remaining Longevity 72472^MDC_IDC_MSMT_ BATTERY_REMAINING_ LONGEVITY^MDC mo^months^mdc Measured Device Battery Remaining Percentage 72536^MDC_IDC_MSMT_ BATTERY_REMAINING_ PERCENTAGE^MDC %^percent^mdc Measured Device Battery Voltage 72344^MDC_IDC_MSMT_ BATTERY_VOLTAGE^MDC V^volts^MDC Measured Device Battery Impedance 72408^MDC_IDC_MSMT_ BATTERY_IMPEDANCE^MDC Ohm^ohms^MDC Measured Device Capacitor Last Full Energy Charge 72856^MDC_IDC_MSMT_CAP_ CHARGE_TYPE^MDC n Measured Device Capacitor Last Full Energy Charge Timestamp DTM 72664^MDC_IDC_MSMT_CAP_ CHARGE_DTM^MDC n Measured Device Capacitor Last Full Energy Charge Interval 72728^MDC_IDC_MSMT_CAP_ CHARGE_TIME^MDC n s^seconds^mdc Measured Device Capacitor Last Charge Energy 72792^MDC_IDC_MSMT_CAP_ CHARGE_ENERGY^MDC n J^joules^MDC Measured Device Capacitor Last Full Energy Charge Voltage 00924^MDT_AT_ CAPACITOR_LACHARGE_ VOLTAGE^MDT n V^volts^MDC Measured Left Ventricle Lead Low Power Channel Status 72987^MDC_IDC_MSMT_ LEADCHNL_LV_LEAD_ CHANNEL_ATUS^MDC Measured Left Ventricle Lead Low Power Channel Sensing Integrity Counter Start Date DTM 00925^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ SENSINGINTEGRITYCOUNTER_ ARTDATE^MDT Measured Left Ventricle Lead Low Power Channel Sensing Integrity Counter End Date DTM 00926^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ SENSINGINTEGRITYCOUNTER_ ENDDATE^MDT Measured Left Ventricle Lead Low Power 00927^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_
177 Connectivity Guide Paceart Integration 75 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Channel Sensing Integrity Counter Count SENSINGINTEGRITYCOUNTER_ COUNT^MDT Measured Left Ventricle Lead Low Power Channel Evoked Response 00928^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ EVOKEDRESPONSE^MDT Measured Left Ventricle Lead Low Power Channel Polarization 00929^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ POLARIZATION^MDT V^volts^MDC Measured Left Ventricle Lead Low Power Channel Impedance Measurement Value 0053^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ IMPEDANCE_MEASURED_ VALUE^MDT LV_Impedance_Counter ohm^ohms^mdc Measured Left Ventricle Lead Low Power Channel Impedance Measurement Value 0055^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ IMPEDANCE_MAIMUM_ VALUE^MDT LV_Impedance_Counter ohm^ohms^mdc Measured Left Ventricle Lead Low Power Channel Impedance Measurement Value 0054^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ IMPEDANCE_MINIMUM_ VALUE^MDT LV_Impedance_Counter ohm^ohms^mdc Measured Left Ventricle Lead Low Power Channel Impedance Measurement Value 0056^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ IMPEDANCE_MEAN_VALUE^MDT LV_Impedance_Counter ohm^ohms^mdc Measured Left Ventricle Lead Low Power Channel Impedance Measurement Method 0052^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ IMPEDANCE_METHOD^MDT LV_Impedance_Counter Measured Left Ventricle Lead Low Power Channel Impedance Start Date DTM 0058^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ IMPEDANCE_ARTDATE^MDT LV_Impedance_Counter Measured Left Ventricle Lead Low Power Channel Impedance End Date DTM 0059^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ IMPEDANCE_ENDDATE^MDT LV_Impedance_Counter Measured Left Ventricle Lead Low Power Channel Impedance Method Variance 0057^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ IMPEDANCE_METHOD_ VARIANCE^MDT LV_Impedance_Counter d^day^ucum Measured Left Ventricle Lead Low Power Channel Impedance Polarity 0060^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ IMPEDANCE_POLARITY^MDT LV_Impedance_Counter Measured Left Ventricle Lead Low Power Channel Impedance Polarity 006^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ IMPEDANCES_POLE_TYPE^MDT LV_Impedance_Counter.LV_ Impedance_Pole_Counter Measured Left Ventricle Lead Low Power Channel Impedance 0062^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ IMPEDANCES_POLE_ LOCATION^MDT LV_Impedance_Counter.LV_ Impedance_Pole_Counter Measured Left Ventricle Lead Low Power Channel Impedance 0063^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ IMPEDANCES_POLE_ ELECTRODE^MDT LV_Impedance_Counter.LV_ Impedance_Pole_Counter Measured Left Ventricle Lead Sensing Threshold Amplitude 0089^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ SENSITIVITIES_MEASURED_ VALUE^MDT LV_Sensitivity_Counter mv^millivolts^mdc Measured Left Ventricle Lead Sensing Threshold Amplitude 009^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ SENSITIVITIES_MAIMUM_ VALUE^MDT LV_Sensitivity_Counter mv^millivolts^mdc
178 76 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Measured Left Ventricle Lead Sensing Threshold Amplitude 0090^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ SENSITIVITIES_MINIMUM_ VALUE^MDT LV_Sensitivity_Counter mv^millivolts^mdc Measured Left Ventricle Lead Sensing Threshold Amplitude 0092^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ SENSITIVITIES_MEAN_ VALUE^MDT LV_Sensitivity_Counter mv^millivolts^mdc Measured Left Ventricle Lead Sensing Threshold Measurement Method 0088^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ SENSITIVITIES_METHOD^MDT LV_Sensitivity_Counter Measured Left Ventricle Lead Sensing Threshold Start Date DTM 0094^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ SENSITIVITIES_ ARTDATE^MDT LV_Sensitivity_Counter Measured Left Ventricle Lead Sensing Threshold End Date DTM 0095^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ SENSITIVITIES_ENDDATE^MDT LV_Sensitivity_Counter Measured Left Ventricle Lead Sensing Threshold Method Variance 0093^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ SENSITIVITIES_METHOD_ VARIANCE^MDT LV_Sensitivity_Counter d^day^ucum Measured Left Ventricle Lead Sensing Threshold Polarity 0096^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ SENSITIVITIES_POLARITY^MDT LV_Sensitivity_Counter Measured Left Ventricle Lead Sensing Threshold Polarity 0097^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ SENSITIVITIES_POLE_TYPE^MDT LV_Sensitivity_Counter.LV_ Sensitivity_Pole_Counter Measured Left Ventricle Lead Sensing Threshold 0098^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ SENSITIVITIES_POLE_ LOCATION^MDT LV_Sensitivity_Counter.LV_ Sensitivity_Pole_Counter Measured Left Ventricle Lead Sensing Threshold 0099^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ SENSITIVITIES_POLE_ ELECTRODE^MDT LV_Sensitivity_Counter.LV_ Sensitivity_Pole_Counter Measured Left Ventricle Lead Capture Threshold Amplitude 00235^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ CAPTURES_AMPLITUDE^MDT LV_Capture_Counter v^volts^mdc Measured Left Ventricle Lead Capture Threshold Duration 00236^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ CAPTURES_DURATION^MDT LV_Capture_Counter Measured Left Ventricle Lead Capture Threshold Measurement Method 00234^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ CAPTURES_METHOD^MDT LV_Capture_Counter Measured Left Ventricle Lead Capture Threshold Start Date DTM 00238^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ CAPTURES_ARTDATE^MDT LV_Capture_Counter Measured Left Ventricle Lead Capture Threshold End Date DTM 00239^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ CAPTURES_ENDDATE^MDT LV_Capture_Counter Measured Left Ventricle Lead Capture Threshold Method Variance 00237^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ CAPTURES_METHOD_ VARIANCE^MDT LV_Capture_Counter d^day^ucum Measured Left Ventricle Lead Capture Threshold Polarity 00240^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ CAPTURES_POLARITY^MDT LV_Capture_Counter Measured Left Ventricle Lead Capture Threshold Polarity 0024^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ CAPTURES_POLE_TYPE^MDT LV_Capture_Counter.LV_ Capture_Pole_Counter
179 Connectivity Guide Paceart Integration 77 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Measured Left Ventricle Lead Capture Threshold 00242^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ CAPTURES_POLE_ LOCATION^MDT LV_Capture_Counter.LV_ Capture_Pole_Counter Measured Left Ventricle Lead Capture Threshold 00243^MDT_AT_LEADS_ LOWPOWERCHANNEL_LV_ CAPTURES_POLE_ ELECTRODE^MDT LV_Capture_Counter.LV_ Capture_Pole_Counter Measured Right Atrium Lead Low Power Channel Status 72984^MDC_IDC_MSMT_ LEADCHNL_RA_LEAD_ CHANNEL_ATUS^MDC Measured Right Atrium Lead Low Power Channel Sensing Integrity Counter Start Date DTM 00224^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ SENSINGINTEGRITYCOUNTER_ ARTDATE^MDT Measured Right Atrium Lead Low Power Channel Sensing Integrity Counter End Date DTM 00225^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ SENSINGINTEGRITYCOUNTER_ ENDDATE^MDT Measured Right Atrium Lead Low Power Channel Sensing Integrity Counter Count 00226^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ SENSINGINTEGRITYCOUNTER_ COUNT^MDT Measured Right Atrium Lead Low Power Channel Evoked Response 00227^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ EVOKEDRESPONSE^MDT Measured Right Atrium Lead Low Power Channel Polarization 00228^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ POLARIZATION^MDT V^volts^MDC Measured Right Atrium Lead Low Power Channel Impedance Measurement Value 0065^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ IMPEDANCE_MEASURED_ VALUE^MDT RA_Impedance_Counter ohm^ohms^mdc Measured Right Atrium Lead Low Power Channel Impedance Measurement Value 0067^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ IMPEDANCE_MAIMUM_ VALUE^MDT RA_Impedance_Counter ohm^ohms^mdc Measured Right Atrium Lead Low Power Channel Impedance Measurement Value 0066^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ IMPEDANCE_MINIMUM_ VALUE^MDT RA_Impedance_Counter ohm^ohms^mdc Measured Right Atrium Lead Low Power Channel Impedance Measurement Value 0068^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ IMPEDANCE_MEAN_VALUE^MDT RA_Impedance_Counter ohm^ohms^mdc Measured Right Atrium Lead Low Power Channel Impedance Measurement Method 0064^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ IMPEDANCE_METHOD^MDT RA_Impedance_Counter Measured Right Atrium Lead Low Power Channel Impedance Start Date DTM 0070^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ IMPEDANCE_ARTDATE^MDT RA_Impedance_Counter Measured Right Atrium Lead Low Power Channel Impedance End Date DTM 007^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ IMPEDANCE_ENDDATE^MDT RA_Impedance_Counter Measured Right Atrium Lead Low Power Channel Impedance Method Variance 0069^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ IMPEDANCE_METHOD_ VARIANCE^MDT RA_Impedance_Counter d^day^ucum Measured Right Atrium Lead Low Power Channel Impedance Polarity 0072^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ IMPEDANCE_POLARITY^MDT RA_Impedance_Counter
180 78 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Measured Right Atrium Lead Low Power Channel Impedance Polarity 0073^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ IMPEDANCES_POLE_TYPE^MDT RA_Impedance_Counter.RA_ Impedance_Pole_Counter Measured Right Atrium Lead Low Power Channel Impedance 0074^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ IMPEDANCES_POLE_ LOCATION^MDT RA_Impedance_Counter.RA_ Impedance_Pole_Counter Measured Right Atrium Lead Low Power Channel Impedance 075^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ IMPEDANCES_POLE_ ELECTRODE^MDT RA_Impedance_Counter.RA_ Impedance_Pole_Counter Measured Right Atrium Lead Sensing Threshold Amplitude 0020^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ SENSITIVITIES_MEASURED_ VALUE^MDT RA_Sensitivity_Counter mv^millivolts^mdc Measured Right Atrium Lead Sensing Threshold Amplitude 00203^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ SENSITIVITIES_MAIMUM_ VALUE^MDT RA_Sensitivity_Counter mv^millivolts^mdc Measured Right Atrium Lead Sensing Threshold Amplitude 00202^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ SENSITIVITIES_MINIMUM_ VALUE^MDT RA_Sensitivity_Counter mv^millivolts^mdc Measured Right Atrium Lead Sensing Threshold Amplitude 00204^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ SENSITIVITIES_MEAN_ VALUE^MDT RA_Sensitivity_Counter mv^millivolts^mdc Measured Right Atrium Lead Sensing Threshold Measurement Method 00200^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ SENSITIVITIES_METHOD^MDT RA_Sensitivity_Counter Measured Right Atrium Lead Sensing Threshold Start Date DTM 00206^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ SENSITIVITIES_ ARTDATE^MDT RA_Sensitivity_Counter Measured Right Atrium Lead Sensing Threshold End Date DTM 00207^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ SENSITIVITIES_ENDDATE^MDT RA_Sensitivity_Counter Measured Right Atrium Lead Sensing Threshold Method Variance 00205^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ SENSITIVITIES_METHOD_ VARIANCE^MDT RA_Sensitivity_Counter d^day^ucum Measured Right Atrium Lead Sensing Threshold Polarity 00208^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ SENSITIVITIES_POLARITY^MDT RA_Sensitivity_Counter Measured Right Atrium Lead Sensing Threshold Polarity 00209^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ SENSITIVITIES_POLE_TYPE^MDT RA_Sensitivity_Counter.RA_ Sensitivity_Pole_Counter Measured Right Atrium Lead Sensing Threshold 0020^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ SENSITIVITIES_POLE_ LOCATION^MDT RA_Sensitivity_Counter.RA_ Sensitivity_Pole_Counter Measured Right Atrium Lead Sensing Threshold 002^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ SENSITIVITIES_POLE_ ELECTRODE^MDT RA_Sensitivity_Counter.RA_ Sensitivity_Pole_Counter Measured Right Atrium Lead Capture Threshold Amplitude 00245^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ CAPTURES_AMPLITUDE^MDT RA_Capture_Counter v^volts^mdc Measured Right Atrium Lead Capture Threshold Duration 00246^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ CAPTURES_DURATION^MDT RA_Capture_Counter
181 Connectivity Guide Paceart Integration 79 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Measured Right Atrium Lead Capture Threshold Measurement Method 00244^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ CAPTURES_METHOD^MDT RA_Capture_Counter Measured Right Atrium Lead Capture Threshold Start Date DTM 00248^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ CAPTURES_ARTDATE^MDT RA_Capture_Counter Measured Right Atrium Lead Capture Threshold End Date DTM 00249^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ CAPTURES_ENDDATE^MDT RA_Capture_Counter Measured Right Atrium Lead Capture Threshold Method Variance 00247^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ CAPTURES_METHOD_ VARIANCE^MDT RA_Capture_Counter d^day^ucum Measured Right Atrium Lead Capture Threshold Polarity 00250^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ CAPTURES_POLARITY^MDT RA_Capture_Counter Measured Right Atrium Lead Capture Threshold Polarity 0025^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ CAPTURES_POLE_TYPE^MDT RA_Capture_Counter.RA_ Capture_Pole_Counter Measured Right Atrium Lead Capture Threshold 00252^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ CAPTURES_POLE_ LOCATION^MDT RA_Capture_Counter.RA_ Capture_Pole_Counter Measured Right Atrium Lead Capture Threshold 00253^MDT_AT_LEADS_ LOWPOWERCHANNEL_RA_ CAPTURES_POLE_ ELECTRODE^MDT RA_Capture_Counter.RA_ Capture_Pole_Counter Measured Right Ventricle Lead Low Power Channel Status 72985^MDC_IDC_MSMT_ LEADCHNL_RV_LEAD_ CHANNEL_ATUS^MDC Measured Right Ventricle Lead Low Power Channel Sensing Integrity Counter Start Date DTM 00229^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ SENSINGINTEGRITYCOUNTER_ ARTDATE^MDT Measured Right Ventricle Lead Low Power Channel Sensing Integrity Counter End Date DTM 00230^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ SENSINGINTEGRITYCOUNTER_ ENDDATE^MDT Measured Right Ventricle Lead Low Power Channel Sensing Integrity Counter Count 0023^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ SENSINGINTEGRITYCOUNTER_ COUNT^MDT Measured Right Ventricle Lead Low Power Channel Evoked Response 00232^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ EVOKEDRESPONSE^MDT Measured Right Ventricle Lead Low Power Channel Polarization 00233^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ POLARIZATION^MDT V^volts^MDC Measured Right Ventricle Lead Low Power Channel Impedance Measurement Value 0077^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ IMPEDANCE_MEASURED_ VALUE^MDT RV_Impedance_Counter ohm^ohms^mdc Measured Right Ventricle Lead Low Power Channel Impedance Measurement Value 0079^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ IMPEDANCE_MAIMUM_ VALUE^MDT RV_Impedance_Counter ohm^ohms^mdc Measured Right Ventricle Lead Low Power Channel Impedance Measurement Value 0078^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ IMPEDANCE_MINIMUM_ VALUE^MDT RV_Impedance_Counter ohm^ohms^mdc
182 80 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Measured Right Ventricle Lead Low Power Channel Impedance Measurement Value 0080^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ IMPEDANCE_MEAN_VALUE^MDT RV_Impedance_Counter ohm^ohms^mdc Measured Right Ventricle Lead Low Power Channel Impedance Measurement Method 0076^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ IMPEDANCE_METHOD^MDT RV_Impedance_Counter Measured Right Ventricle Lead Low Power Channel Impedance Start Date DTM 0082^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ IMPEDANCE_ARTDATE^MDT RV_Impedance_Counter Measured Right Ventricle Lead Low Power Channel Impedance End Date DTM 0083^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ IMPEDANCE_ENDDATE^MDT RV_Impedance_Counter Measured Right Ventricle Lead Low Power Channel Impedance Method Variance 008^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ IMPEDANCE_METHOD_ VARIANCE^MDT RV_Impedance_Counter d^day^ucum Measured Right Ventricle Lead Low Power Channel Impedance Polarity 0084^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ IMPEDANCE_POLARITY^MDT RV_Impedance_Counter Measured Right Ventricle Lead Low Power Channel Impedance Polarity 0085^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ IMPEDANCES_POLE_TYPE^MDT RV_Impedance_Counter.RV_ Impedance_Pole_Counter Measured Right Ventricle Lead Low Power Channel Impedance 0086^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ IMPEDANCES_POLE_ LOCATION^MDT RV_Impedance_Counter.RV_ Impedance_Pole_Counter Measured Right Ventricle Lead Low Power Channel Impedance 0087^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ IMPEDANCES_POLE_ ELECTRODE^MDT RV_Impedance_Counter.RV_ Impedance_Pole_Counter Measured Right Ventricle Lead Sensing Threshold Amplitude 0023^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ SENSITIVITIES_MEASURED_ VALUE^MDT RV_Sensitivity_Counter mv^millivolts^mdc Measured Right Ventricle Lead Sensing Threshold Amplitude 0025^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ SENSITIVITIES_MAIMUM_ VALUE^MDT RV_Sensitivity_Counter mv^millivolts^mdc Measured Right Ventricle Lead Sensing Threshold Amplitude 0024^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ SENSITIVITIES_MINIMUM_ VALUE^MDT RV_Sensitivity_Counter mv^millivolts^mdc Measured Right Ventricle Lead Sensing Threshold Amplitude 0026^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ SENSITIVITIES_MEAN_ VALUE^MDT RV_Sensitivity_Counter mv^millivolts^mdc Measured Right Ventricle Lead Sensing Threshold Measurement Method 0022^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ SENSITIVITIES_METHOD^MDT RV_Sensitivity_Counter Measured Right Ventricle Lead Sensing Threshold Start Date DTM 0028^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ SENSITIVITIES_ ARTDATE^MDT RV_Sensitivity_Counter Measured Right Ventricle Lead Sensing Threshold End Date DTM 0029^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ SENSITIVITIES_ENDDATE^MDT RV_Sensitivity_Counter
183 Connectivity Guide Paceart Integration 8 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Measured Right Ventricle Lead Sensing Threshold Method Variance 0027^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ SENSITIVITIES_METHOD_ VARIANCE^MDT RV_Sensitivity_Counter d^day^ucum Measured Right Ventricle Lead Sensing Threshold Polarity 00220^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ SENSITIVITIES_POLARITY^MDT RV_Sensitivity_Counter Measured Right Ventricle Lead Sensing Threshold Polarity 0022^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ SENSITIVITIES_POLE_TYPE^MDT RV_Sensitivity_Counter.RV_ Sensitivity_Pole_Counter Measured Right Ventricle Lead Sensing Threshold 00222^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ SENSITIVITES_POLE_ LOCATION^MDT RV_Sensitivity_Counter.RV_ Sensitivity_Pole_Counter Measured Right Ventricle Lead Sensing Threshold 00223^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ SENSITIVITIES_POLE_ ELECTRODE^MDT RV_Sensitivity_Counter.RV_ Sensitivity_Pole_Counter Measured Right Ventricle Lead Capture Threshold Amplitude 00255^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ CAPTURES_AMPLITUDE^MDT RV_Capture_Counter v^volts^mdc Measured Right Ventricle Lead Capture Threshold Duration 00256^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ CAPTURES_DURATION^MDT RV_Capture_Counter Measured Right Ventricle Lead Capture Threshold Measurement Method 00254^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ CAPTURES_METHOD^MDT RV_Capture_Counter Measured Right Ventricle Lead Capture Threshold Start Date DTM 00258^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ CAPTURES_ARTDATE^MDT RV_Capture_Counter Measured Right Ventricle Lead Capture Threshold End Date DTM 00259^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ CAPTURES_ENDDATE^MDT RV_Capture_Counter Measured Right Ventricle Lead Capture Threshold Method Variance 00257^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ CAPTURES_METHOD_ VARIANCE^MDT RV_Capture_Counter d^day^ucum Measured Right Ventricle Lead Capture Threshold Polarity 00260^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ CAPTURES_POLARITY^MDT RV_Capture_Counter Measured Right Ventricle Lead Capture Threshold Polarity 0026^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ CAPTURES_POLE_TYPE^MDT RV_Capture_Counter.RV_ Capture_Pole_Counter Measured Right Ventricle Lead Capture Threshold 00262^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ CAPTURES_POLE_ LOCATION^MDT RV_Capture_Counter.RV_ Capture_Pole_Counter Measured Right Ventricle Lead Capture Threshold 00263^MDT_AT_LEADS_ LOWPOWERCHANNEL_RV_ CAPTURES_POLE_ ELECTRODE^MDT RV_Capture_Counter.RV_ Capture_Pole_Counter Measured Right Ventricle Lead High Power Channel Impedance Measurement Value 00264^MDT_AT_LEADS_ HIGHPOWERCHANNEL_ IMPEDANCES_MEASURED_ VALUE^MDT RV_Impedance_Counter ohm^ohms^mdc Measured Right Ventricle Lead High Power Channel Impedance Measurement Value 00266^MDT_AT_LEADS_ HIGHPOWERCHANNEL_ IMPEDANCES_MAIMUM_ VALUE^MDT RV_Impedance_Counter ohm^ohms^mdc Measured Right Ventricle Lead High Power 00265^MDT_AT_LEADS_ HIGHPOWERCHANNEL_ RV_Impedance_Counter ohm^ohms^mdc
184 82 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Channel Impedance Measurement Value IMPEDANCES_MINIMUM_ VALUE^MDT Measured Right Ventricle Lead High Power Channel Impedance Measurement Value 00267^MDT_AT_LEADS_ HIGHPOWERCHANNEL_ IMPEDANCES_MEAN_ VALUE^MDT RV_Impedance_Counter ohm^ohms^mdc Measured Right Ventricle Lead High Power Channel Status 00096^MDT_AT_LEADS_ HIGHPOWERCHANNEL_ IMPEDANCES_ATUS^MDT RV_Impedance_Counter Measured Right Ventricle Lead High Power Channel Impedance Measurement Method ^MDT_AT_LEADS_ HIGHPOWERCHANNEL_ IMPEDANCES_METHOD^MDT RV_Impedance_Counter Measured Right Ventricle Lead High Power Channel Impedance Method Variance ^MDT_AT_LEADS_ HIGHPOWERCHANNEL_ IMPEDANCES_METHOD_ VARIANCE^MDT RV_Impedance_Counter d^day^ucum Measured Right Ventricle Lead High Power Channel Impedance Start Date DTM ^MDT_AT_LEADS_ HIGHPOWERCHANNEL_ IMPEDANCES_ARTDATE^MDT RV_Impedance_Counter Measured Right Ventricle Lead High Power Channel Impedance End Date DTM ^MDT_AT_LEADS_ HIGHPOWERCHANNEL_ IMPEDANCES_ENDDATE^MDT RV_Impedance_Counter Measured Right Ventricle Lead High Power Channel Impedance Polarity ^MDT_AT_LEADS_ HIGHPOWERCHANNEL_ IMPEDANCES_PATHWAY_POLE_ TYPE^MDT RV_Impedance_ Counter.HighPowerChannel_ Impedance_Pole_Counter Measured Right Ventricle Lead High Power Channel Impedance ^MDT_AT_LEADS_ HIGHPOWERCHANNEL_ IMPEDANCES_PATHWAY_POLE_ LOCATION^MDT RV_Impedance_ Counter.HighPowerChannel_ Impedance_Pole_Counter Measured Right Ventricle Lead High Power Channel Impedance ^MDT_AT_LEADS_ HIGHPOWERCHANNEL_ IMPEDANCES_PATHWAY_POLE_ ELECTRODE^MDT RV_Impedance_ Counter.HighPowerChannel_ Impedance_Pole_Counter Measured Physiological Measurements Since Last Session Start Date DTM 73767^MDC_IDC_AT_ HEART_RATE_DTM_ART^MDC Measured Physiological Measurements Since Last Session End Date DTM 73768^MDC_IDC_AT_ HEART_RATE_DTM_END^MDC Measured Physiological Measurements Since Last Session Right Atrium Measured Heart Rate ^MDC_IDC_AT_ HEART_RATE_ATRIAL^MDC {beats}/min^heartbeats per minute^mdc Measured Physiological Measurements Since Last Session Right Atrium Minimum Heart Rate ^MDC_IDC_AT_ HEART_RATE_ATRIAL_MIN^MDC {beats}/min^heartbeats per minute^mdc Measured Physiological Measurements Since Last Session Right Atrium Maximum Heart Rate ^MDC_IDC_AT_ HEART_RATE_ATRIAL_ MA^MDC {beats}/min^heartbeats per minute^mdc Measured Physiological Measurements Since Last Session Right Atrium Mean Heart Rate ^MDC_IDC_AT_ HEART_RATE_ATRIAL_ MEAN^MDC {beats}/min^heartbeats per minute^mdc
185 Connectivity Guide Paceart Integration 83 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Measured Physiological Measurements Since Last Session Right Ventricle Measured Heart Rate ^MDC_IDC_AT_ HEART_RATE_ VENTRICULAR^MDC {beats}/min^heartbeats per minute^mdc Measured Physiological Measurements Since Last Session Right Ventricle Minimum Heart Rate ^MDC_IDC_AT_ HEART_RATE_VENTRICULAR_ MIN^MDC {beats}/min^heartbeats per minute^mdc Measured Physiological Measurements Since Last Session Right Ventricle Maximum Heart Rate ^MDC_IDC_AT_ HEART_RATE_VENTRICULAR_ MA^MDC {beats}/min^heartbeats per minute^mdc Measured Physiological Measurements Since Last Session Right Ventricle Mean Heart Rate 73765^MDC_IDC_AT_ HEART_RATE_VENTRICULAR_ MEAN^MDC {beats}/min^heartbeats per minute^mdc Measured Physiological Measurements Since Last Counter Reset Start Date DTM 00098^MDT_AT_ DETECTIONS_THERAPIES_ PHYSIOLOGICAL_SINCERESET_ ARTDATE^MDT Measured Physiological Measurements Since Last Counter Reset End Date DTM 00099^MDT_AT_ DETECTIONS_THERAPIES_ PHYSIOLOGICAL_SINCERESET_ ENDDATE^MDT Measured Physiological Measurements Since Last Counter Reset Right Atrium Measured Heart Rate 0000^MDT_AT_ DETECTIONS_THERAPIES_ PHYSIOLOGICAL_SINCERESET_ HEART_RATE_ATRIAL^MDT {beats}/min^heartbeats per minute^mdc Measured Physiological Measurements Since Last Counter Reset Right Atrium Minimum Heart Rate 000^MDT_AT_ DETECTIONS_THERAPIES_ PHYSIOLOGICAL_SINCERESET_ HEART_RATE_ATRIAL_MIN^MDT {beats}/min^heartbeats per minute^mdc Measured Physiological Measurements Since Last Counter Reset Right Atrium Maximum Heart Rate 0002^MDT_AT_ DETECTIONS_THERAPIES_ PHYSIOLOGICAL_SINCERESET_ HEART_RATE_ATRIAL_ MA^MDT {beats}/min^heartbeats per minute^mdc Measured Physiological Measurements Since Last Counter Reset Right Atrium Mean Heart Rate 0003^MDT_AT_ DETECTIONS_THERAPIES_ PHYSIOLOGICAL_SINCERESET_ HEART_RATE_ATRIAL_ MEAN^MDT {beats}/min^heartbeats per minute^mdc Measured Physiological Measurements Since Last Counter Reset Right Ventricle Measured Heart Rate 0004^MDT_AT_ DETECTIONS_THERAPIES_ PHYSIOLOGICAL_SINCERESET_ HEART_RATE_ VENTRICULAR^MDT {beats}/min^heartbeats per minute^mdc Measured Physiological Measurements Since Last Counter Reset Right Ventricle Minimum Heart Rate 0005^MDT_AT_ DETECTIONS_THERAPIES_ PHYSIOLOGICAL_SINCERESET_ HEART_RATE_VENTRICULAR_ MIN^MDT {beats}/min^heartbeats per minute^mdc Measured Physiological Measurements Since Last Counter Reset Right Ventricle Maximum Heart Rate 0006^MDT_AT_ DETECTIONS_THERAPIES_ PHYSIOLOGICAL_SINCERESET_ HEART_RATE_VENTRICULAR_ MA^MDT {beats}/min^heartbeats per minute^mdc
186 84 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Measured Physiological Measurements Since Last Counter Reset Right Ventricle Mean Heart Rate 0007^MDT_AT_ DETECTIONS_THERAPIES_ PHYSIOLOGICAL_SINCERESET_ HEART_RATE_VENTRICULAR_ MEAN^MDT {beats}/min^heartbeats per minute^mdc Measured Physiological Measurements Lifetime Start Date DTM 0008^MDT_AT_ DETECTIONS_THERAPIES_ PHYSIOLOGICAL_LIFETIME_ ARTDATE^MDT Measured Physiological Measurements Lifetime End Date DTM 0009^MDT_AT_ DETECTIONS_THERAPIES_ PHYSIOLOGICAL_LIFETIME_ ENDDATE^MDT Measured Physiological Measurements Lifetime Right Atrium Measured Heart Rate 000^MDT_AT_ DETECTIONS_THERAPIES_ PHYSIOLOGICAL_LIFETIME_ HEART_RATE_ATRIAL^MDT {beats}/min^heartbeats per minute^mdc Measured Physiological Measurements Lifetime Right Atrium Minimum Heart Rate 00^MDT_AT_ DETECTIONS_THERAPIES_ PHYSIOLOGICAL_LIFETIME_ HEART_RATE_ATRIAL_MIN^MDT {beats}/min^heartbeats per minute^mdc Measured Physiological Measurements Lifetime Right Atrium Maximum Heart Rate 002^MDT_AT_ DETECTIONS_THERAPIES_ PHYSIOLOGICAL_LIFETIME_ HEART_RATE_ATRIAL_ MA^MDT {beats}/min^heartbeats per minute^mdc Measured Physiological Measurements Lifetime Right Atrium Mean Heart Rate 003^MDT_AT_ DETECTIONS_THERAPIES_ PHYSIOLOGICAL_LIFETIME_ HEART_RATE_ATRIAL_ MEAN^MDT {beats}/min^heartbeats per minute^mdc Measured Physiological Measurements Lifetime Right Ventricle Measured Heart Rate 004^MDT_AT_ DETECTIONS_THERAPIES_ PHYSIOLOGICAL_LIFETIME_ HEART_RATE_ VENTRICULAR^MDT {beats}/min^heartbeats per minute^mdc Measured Physiological Measurements Lifetime Right Ventricle Minimum Heart Rate 005^MDT_AT_ DETECTIONS_THERAPIES_ PHYSIOLOGICAL_LIFETIME_ HEART_RATE_VENTRICULAR_ MIN^MDT {beats}/min^heartbeats per minute^mdc Measured Physiological Measurements Lifetime Right Ventricle Maximum Heart Rate 006^MDT_AT_ DETECTIONS_THERAPIES_ PHYSIOLOGICAL_LIFETIME_ HEART_RATE_VENTRICULAR_ MA^MDT {beats}/min^heartbeats per minute^mdc Measured Physiological Measurements Lifetime Right Ventricle Mean Heart Rate 007^MDT_AT_ DETECTIONS_THERAPIES_ PHYSIOLOGICAL_LIFETIME_ HEART_RATE_VENTRICULAR_ MEAN^MDT {beats}/min^heartbeats per minute^mdc Measured Bradycardia Measurements Since Last Session Start Date DTM ^MDC_IDC_AT_ BRADY_DTM_ART^MDC Measured Bradycardia Measurements Since Last Session End Date DTM ^MDC_IDC_AT_ BRADY_DTM_END^MDC Measured Bradycardia Measurements Since Last Session Left Ventricle Percent Paced ^MDC_IDC_AT_CRT_ LV_PERCENT_PACED^MDC %^percent^mdc
187 Connectivity Guide Paceart Integration 85 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Measured Bradycardia Measurements Since Last Session Right Ventricle Percent Paced ^MDC_IDC_AT_ BRADY_RV_PERCENT_ PACED^MDC %^percent^mdc Measured Bradycardia Measurements Since Last Session Right Atrium Percent Paced ^MDC_IDC_AT_ BRADY_RA_PERCENT_ PACED^MDC %^percent^mdc Measured Bradycardia Measurements Since Last Session AP VP Percent ^MDC_IDC_AT_ BRADY_AP_VP_PERCENT^MDC %^percent^mdc Measured Bradycardia Measurements Since Last Session AS VP Percent ^MDC_IDC_AT_ BRADY_AS_VP_PERCENT^MDC %^percent^mdc Measured Bradycardia Measurements Since Last Session AP VS Percent ^MDC_IDC_AT_ BRADY_AP_VS_PERCENT^MDC %^percent^mdc Measured Bradycardia Measurements Since Last Session AS VS Percent ^MDC_IDC_AT_ BRADY_AS_VS_PERCENT^MDC %^percent^mdc Measured Bradycardia Measurements Since Last Counter Reset Start Date DTM 008^MDT_AT_ DETECTIONS_THERAPIES_ BRADYCARDIA_SINCERESET_ ARTDATE^MDT Measured Bradycardia Measurements Since Last Counter Reset End Date DTM 009^MDT_AT_ DETECTIONS_THERAPIES_ BRADYCARDIA_SINCERESET_ ENDDATE^MDT Measured Bradycardia Measurements Since Last Counter Reset Left Ventricle Percent Paced 0020^MDT_AT_ DETECTIONS_THERAPIES_ BRADYCARDIA_SINCERESET_ PERCENTPACED_LV^MDT %^percent^mdc Measured Bradycardia Measurements Since Last Counter Reset Right Ventricle Percent Paced 002^MDT_AT_ DETECTIONS_THERAPIES_ BRADYCARDIA_SINCERESET_ PERCENTPACED_RV^MDT %^percent^mdc Measured Bradycardia Measurements Since Last Counter Reset Right Atrium Percent Paced 0022^MDT_AT_ DETECTIONS_THERAPIES_ BRADYCARDIA_SINCERESET_ PERCENTPACED_RA^MDT %^percent^mdc Measured Bradycardia Measurements Since Last Counter Reset AP VP Percent 0023^MDT_AT_ DETECTIONS_THERAPIES_ BRADYCARDIA_SINCERESET_ APVPPERCENT^MDT %^percent^mdc Measured Bradycardia Measurements Since Last Counter Reset AS VP Percent 0024^MDT_AT_ DETECTIONS_THERAPIES_ BRADYCARDIA_SINCERESET_ ASVPPERCENT^MDT %^percent^mdc Measured Bradycardia Measurements Since Last Counter Reset AP VS Percent 0025^MDT_AT_ DETECTIONS_THERAPIES_ BRADYCARDIA_SINCERESET_ APVSPERCENT^MDT %^percent^mdc Measured Bradycardia Measurements Since Last Counter Reset AS VS Percent 0026^MDT_AT_ DETECTIONS_THERAPIES_ BRADYCARDIA_SINCERESET_ ASVSPERCENT^MDT %^percent^mdc Measured Bradycardia Measurements Lifetime Start Date DTM 0027^MDT_AT_ DETECTIONS_THERAPIES_ BRADYCARDIA_LIFETIME_ ARTDATE^MDT
188 86 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Measured Bradycardia Measurements Lifetime End Date DTM 0028^MDT_AT_ DETECTIONS_THERAPIES_ BRADYCARDIA_LIFETIME_ ENDDATE^MDT Measured Bradycardia Measurements Lifetime Left Ventricle Percent Paced 0029^MDT_AT_ DETECTIONS_THERAPIES_ BRADYCARDIA_LIFETIME_ PERCENTPACED_LV^MDT %^percent^mdc Measured Bradycardia Measurements Lifetime Right Ventricle Percent Paced 0030^MDT_AT_ DETECTIONS_THERAPIES_ BRADYCARDIA_LIFETIME_ PERCENTPACED_RV^MDT %^percent^mdc Measured Bradycardia Measurements Lifetime Right Atrium Percent Paced 003^MDT_AT_ DETECTIONS_THERAPIES_ BRADYCARDIA_LIFETIME_ PERCENTPACED_RA^MDT %^percent^mdc Measured Bradycardia Measurements Lifetime AP VP Percent 0032^MDT_AT_ DETECTIONS_THERAPIES_ BRADYCARDIA_LIFETIME_ APVPPERCENT^MDT %^percent^mdc Measured Bradycardia Measurements Lifetime AS VP Percent 0033^MDT_AT_ DETECTIONS_THERAPIES_ BRADYCARDIA_LIFETIME_ ASVPPERCENT^MDT %^percent^mdc Measured Bradycardia Measurements Lifetime AP VS Percent 0034^MDT_AT_ DETECTIONS_THERAPIES_ BRADYCARDIA_LIFETIME_ APVSPERCENT^MDT %^percent^mdc Measured Bradycardia Measurements Lifetime AS VS Percent 0035^MDT_AT_ DETECTIONS_THERAPIES_ BRADYCARDIA_LIFETIME_ ASVSPERCENT^MDT %^percent^mdc Measured Atrial Counters Since Last Session Start Date DTM ^MDC_IDC_AT_AT_ DTM_ART^MDC Measured Atrial Counters Since Last Session End Date DTM ^MDC_IDC_AT_AT_ DTM_END^MDC Measured Atrial Counters Since Last Session AT AF Burden ^MDC_IDC_AT_AT_ BURDEN_PERCENT^MDC %^percent^mdc Measured Atrial Counters Since Last Session Mode Switch Maximum Duration ^MDC_IDC_AT_AT_ MODE_SW_MA_ DURATION^MDC s^seconds^mdc Measured Atrial Counters Since Last Session Mode Switch Count ^MDC_IDC_AT_AT_ MODE_SW_COUNT^MDC Measured Atrial Counters Since Last Session Mode Switch Burden 73772^MDC_IDC_AT_AT_ MODE_SW_PERCENT_ TIME^MDC %^percent^mdc Measured Atrial Counters Since Last Session Mode Switch Average Daily Count ^MDC_IDC_AT_AT_ MODE_SW_COUNT_PER_ DAY^MDC Measured Atrial Counters Since Last Session Mode Switch Average Daily Burden ^MDC_IDC_AT_AT_ MODE_SW_PERCENT_TIME_ PER_DAY^MDC %^percent^mdc Measured Atrial Counters Since DTM 0036^MDT_AT_ DETECTIONS_THERAPIES_
189 Connectivity Guide Paceart Integration 87 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Last Counter Reset Start Date ATRIALTACHYCARDIA_ SINCERESET_ARTDATE^MDT Measured Atrial Counters Since Last Counter Reset End Date DTM 0037^MDT_AT_ DETECTIONS_THERAPIES_ ATRIALTACHYCARDIA_ SINCERESET_ENDDATE^MDT Measured Atrial Counters Since Last Counter Reset AT AF Burden 0038^MDT_AT_ DETECTIONS_THERAPIES_ ATRIALTACHYCARDIA_ SINCERESET_ ATAFBURDEN^MDT %^percent^mdc Measured Atrial Counters Since Last Counter Reset Mode Switch Maximum Duration 0039^MDT_AT_ DETECTIONS_THERAPIES_ ATRIALTACHYCARDIA_ SINCERESET_MODESWITCH_ MAIMUMDURATION^MDT s^seconds^mdc Measured Atrial Counters Since Last Counter Reset Mode Switch Count 0040^MDT_AT_ DETECTIONS_THERAPIES_ ATRIALTACHYCARDIA_ SINCERESET_MODESWITCH_ COUNT^MDT Measured Atrial Counters Since Last Counter Reset Mode Switch Burden 004^MDT_AT_ DETECTIONS_THERAPIES_ ATRIALTACHYCARDIA_ SINCERESET_MODESWITCH_ BURDEN^MDT %^percent^mdc Measured Atrial Counters Since Last Counter Reset Mode Switch Average Daily Count 0042^MDT_AT_ DETECTIONS_THERAPIES_ ATRIALTACHYCARDIA_ SINCERESET_MODESWITCH_ AVERAGEDAILYCOUNT^MDT Measured Atrial Counters Since Last Counter Reset Mode Switch Average Daily Burden 0043^MDT_AT_ DETECTIONS_THERAPIES_ ATRIALTACHYCARDIA_ SINCERESET_MODESWITCH_ AVERAGEDAILYBURDEN^MDT %^percent^mdc Measured Atrial Counters Lifetime Start Date DTM 0044^MDT_AT_ DETECTIONS_THERAPIES_ ATRIALTACHYCARDIA_ LIFETIME_ARTDATE^MDT Measured Atrial Counters Lifetime End Date DTM 0045^MDT_AT_ DETECTIONS_THERAPIES_ ATRIALTACHYCARDIA_ LIFETIME_ENDDATE^MDT Measured Atrial Counters Lifetime AT AF Burden 0046^MDT_AT_ DETECTIONS_THERAPIES_ ATRIALTACHYCARDIA_ LIFETIME_ATAFBURDEN^MDT %^percent^mdc Measured Atrial Counters Lifetime Mode Switch Maximum Duration 0047^MDT_AT_ DETECTIONS_THERAPIES_ ATRIALTACHYCARDIA_ LIFETIME_MODESWITCH_ MAIMUMDURATION^MDT s^seconds^mdc Measured Atrial Counters Lifetime Mode Switch Count 0048^MDT_AT_ DETECTIONS_THERAPIES_ ATRIALTACHYCARDIA_ LIFETIME_MODESWITCH_ COUNT^MDT Measured Atrial Counters Lifetime Mode Switch Burden 0049^MDT_AT_ DETECTIONS_THERAPIES_ ATRIALTACHYCARDIA_ LIFETIME_MODESWITCH_ BURDEN^MDT %^percent^mdc Measured Atrial Counters 0050^MDT_AT_ DETECTIONS_THERAPIES_ ATRIALTACHYCARDIA_
190 88 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Lifetime Mode Switch Average Daily Count LIFETIME_MODESWITCH_ AVERAGEDAILYCOUNT^MDT Measured Atrial Counters Lifetime Mode Switch Average Daily Burden 005^MDT_AT_ DETECTIONS_THERAPIES_ ATRIALTACHYCARDIA_ LIFETIME_MODESWITCH_ AVERAGEDAILYBURDEN^MDT %^percent^mdc Measured Heart Failure Counters Since Last Session Start Date DTM ^MDC_IDC_AT_CRT_ DTM_ART^MDC Measured Heart Failure Counters Since Last Session End Date DTM ^MDC_IDC_AT_CRT_ DTM_END^MDC Measured Heart Failure Counters Since Last Session CRT Percent Paced ^MDC_IDC_AT_CRT_ PERCENT_PACED^MDC %^percent^mdc Measured Heart Failure Counters Since Last Counter Reset Start Date DTM 00268^MDT_AT_ DETECTIONS_THERAPIES_ HEARTFAILURE_SINCERESET_ ARTDATE^MDT Measured Heart Failure Counters Since Last Counter Reset End Date DTM 00269^MDT_AT_ DETECTIONS_THERAPIES_ HEARTFAILURE_SINCERESET_ ENDDATE^MDT Measured Heart Failure Counters Since Last Counter Reset CRT Percent Paced 00270^MDT_AT_ DETECTIONS_THERAPIES_ HEARTFAILURE_SINCERESET_ CRTPERCENTPACED^MDT %^percent^mdc Measured Heart Failure Counters Lifetime Start Date DTM 0027^MDT_AT_ DETECTIONS_THERAPIES_ HEARTFAILURE_LIFETIME_ ARTDATE^MDT Measured Heart Failure Counters Lifetime End Date DTM 00272^MDT_AT_ DETECTIONS_THERAPIES_ HEARTFAILURE_LIFETIME_ ENDDATE^MDT Measured Heart Failure Counters Lifetime CRT Percent Paced 00273^MDT_AT_ DETECTIONS_THERAPIES_ HEARTFAILURE_LIFETIME_ CRTPERCENTPACED^MDT %^percent^mdc Measured Detection Counters Since Last Counter Reset Episode Recent Count ^MDC_IDC_AT_ EPISODE_RECENT_COUNT^MDC DT_Episodes_Counter Measured Detection Counters Since Last Counter Reset Episode ^MDC_IDC_AT_ EPISODE_TYPE^MDC DT_Episodes_Counter Measured Detection Counters Since Last Counter Reset Start Date DTM 73807^MDC_IDC_AT_ EPISODE_RECENT_COUNT_ DTM_ART^MDC DT_Episodes_Counter Measured Detection Counters Since Last Counter Reset End Date DTM 73808^MDC_IDC_AT_ EPISODE_RECENT_COUNT_ DTM_END^MDC DT_Episodes_Counter Measured Detection Counters Since Last Counter Reset Extended High Rate / Sustained High Rate ^MDT_AT_ DETECTIONS_THERAPIES_ TACHYCARDIA_DETECTIONS_ ETENDEDHIGHRATE_ SUANEDHIGHRATE^MDT DT_Episodes_Counter
191 Connectivity Guide Paceart Integration 89 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Measured Detection Counters Since Last Counter Reset Single PVCs ^MDT_AT_ DETECTIONS_THERAPIES_ TACHYCARDIA_DETECTIONS_ SINGLEPVCS^MDT DT_Episodes_Counter Measured Detection Counters Since Last Counter Reset Runs of PVCs ^MDT_AT_ DETECTIONS_THERAPIES_ TACHYCARDIA_DETECTIONS_ RUNSOFPVCS^MDT DT_Episodes_Counter Measured Detection Counters Since Last Counter Reset Episode Total Count ^MDC_IDC_AT_ EPISODE_TOTAL_COUNT^MDC DT_Episodes_Counter Measured Detection Counters Lifetime Start Date DTM ^MDC_IDC_AT_ EPISODE_TOTAL_COUNT_DTM_ ART^MDC DT_Episodes_Counter Measured Detection Counters Lifetime End Date DTM ^MDC_IDC_AT_ EPISODE_TOTAL_COUNT_DTM_ END^MDC DT_Episodes_Counter Measured Detection Counters Lifetime Extended High Rate / Sustained High Rate ^MDT_AT_ DETECTIONS_THERAPIES_ TACHYCARDIA_DETECTIONS_ ETENDEDHIGHRATE_ SUANEDHIGHRATE^MDT DT_Episodes_Counter Measured Detection Counters Lifetime Single PVCs ^MDT_AT_ DETECTIONS_THERAPIES_ TACHYCARDIA_DETECTIONS_ SINGLEPVCS^MDT DT_Episodes_Counter Measured Detection Counters Lifetime Runs of PVCs ^MDT_AT_ DETECTIONS_THERAPIES_ TACHYCARDIA_DETECTIONS_ RUNSOFPVCS^MDT DT_Episodes_Counter Measured Detection Counters Since Last Session Episode Count ^MDT_AT_ DETECTIONS_THERAPIES_ TACHYCARDIA_DETECTIONS_ SINCE_LA_SESSION_ COUNT^MDT DT_Episodes_Counter Measured Detection Counters Since Last Session Episode ^MDT_AT_ DETECTIONS_THERAPIES_ TACHYCARDIA_DETECTIONS_ SINCE_LA_SESSION_ TYPE^MDT DT_Episodes_Counter Measured Counters Since Last Session Start Date DTM ^MDT_AT_ DETECTIONS_THERAPIES_ TACHYCARDIA_DETECTIONS_ SINCE_LA_SESSION_ ARTDATE^MDT DT_Episodes_Counter Measured Counters Since Last Session End Date DTM ^MDT_AT_ DETECTIONS_THERAPIES_ TACHYCARDIA_DETECTIONS_ SINCE_LA_SESSION_ ENDDATE^MDT DT_Episodes_Counter Measured Detection Counters Since Last Session Extended High Rate / Sustained High Rate ^MDT_AT_ DETECTIONS_THERAPIES_ TACHYCARDIA_DETECTIONS_ ETENDEDHIGHRATE_ SUANEDHIGHRATE^MDT DT_Episodes_Counter Measured Detection Counters Since Last Session Single PVCs ^MDT_AT_ DETECTIONS_THERAPIES_ TACHYCARDIA_DETECTIONS_ SINGLEPVCS^MDT DT_Episodes_Counter Measured Detection Counters Since Last Session Runs of PVCs ^MDT_AT_ DETECTIONS_THERAPIES_ TACHYCARDIA_DETECTIONS_ RUNSOFPVCS^MDT DT_Episodes_Counter
192 90 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Measured Counters Since Last Session Right Ventricle s Delivered ^MDT_AT_ DETECTIONS_THERAPIES_ TACHYCARDIA_THERAPIES_ SINCE_LA_SESSION_ THERAPY_SHOCKS_ DELIVERED^MDT Measured Counters Since Last Session Right Ventricle s Aborted ^MDT_AT_ DETECTIONS_THERAPIES_ TACHYCARDIA_THERAPIES_ SINCE_LA_SESSION_ THERAPY_SHOCKS_ ABORTED^MDT Measured Counters Since Last Session Right Ventricle ATP Delivered ^MDT_AT_ DETECTIONS_THERAPIES_ TACHYCARDIA_THERAPIES_ SINCE_LA_SESSION_ THERAPY_ATP_ DELIVERED^MDT Measured Counters Since Last Session Start Date DTM ^MDT_AT_ DETECTIONS_THERAPIES_ TACHYCARDIA_THERAPIES_ SINCE_LA_SESSION_ ARTDATE^MDT Measured Counters Since Last Session End Date DTM 00099^MDT_AT_ DETECTIONS_THERAPIES_ TACHYCARDIA_THERAPIES_ SINCE_LA_SESSION_ ENDDATE^MDT Measured Counters Since Last Counter Reset Right Ventricle s Delivered ^MDC_IDC_AT_ TACHYTHERAPY_SHOCKS_ DELIVERED_RECENT^MDC Measured Counters Since Last Counter Reset Right Ventricle s Aborted ^MDC_IDC_AT_ TACHYTHERAPY_SHOCKS_ ABORTED_RECENT^MDC Measured Counters Since Last Counter Reset Right Ventricle ATP Delivered ^MDC_IDC_AT_ TACHYTHERAPY_ATP_ DELIVERED_RECENT^MDC Measured Counters Since Last Counter Reset Start Date DTM ^MDC_IDC_AT_ TACHYTHERAPY_RECENT_ DTM_ART^MDC Measured Counters Since Last Counter Reset End Date DTM ^MDC_IDC_AT_ TACHYTHERAPY_RECENT_ DTM_END^MDC Measured Counters Lifetime Right Ventricle s Delivered ^MDC_IDC_AT_ TACHYTHERAPY_SHOCKS_ DELIVERED_TOTAL^MDC Measured Counters Lifetime Right Ventricle s Aborted ^MDC_IDC_AT_ TACHYTHERAPY_SHOCKS_ ABORTED_TOTAL^MDC Measured Counters Lifetime Right Ventricle ATP Delivered ^MDC_IDC_AT_ TACHYTHERAPY_ATP_ DELIVERED_TOTAL^MDC Measured Counters Lifetime Start Date DTM 73792^MDC_IDC_AT_ TACHYTHERAPY_TOTAL_DTM_ ART^MDC
193 Connectivity Guide Paceart Integration 9 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Measured Counters Lifetime End Date DTM ^MDC_IDC_AT_ TACHYTHERAPY_TOTAL_DTM_ END^MDC Outbound OB Episode Message Segments Paceart parameter type OB-2 OB-3 OB-4 OB-6 Episodes Last Cleared Date DTM ^MDT_EPISODES_LACLEAREDDATE^MDT Episodes Last Interrogation Date DTM ^MDT_EPISODES_LAINTERROGATIONDATE^MDT Episodes Episode Id ^MDC_IDC_EPISODE_ID^MDC Episodes Episode ^MDC_IDC_EPISODE_TYPE^MDC Episodes Episode Start DTM ^MDC_IDC_EPISODE_DTM^MDC Episodes Episode Duration 73972^MDC_IDC_EPISODE_DURATION^MDC s^seconds^mdc Episodes Episode Number of ATP Sequences Delivered ^MDT_EPISODES_EPISODE_ NUMBEROFATPSEQUENCESDELIVERED^MDT Episodes Episode Number of s Delivered ^MDT_EPISODES_EPISODE_ NUMBEROFSHOCKSDELIVERED^MDT Episodes Episode Result ^MDC_IDC_EPISODE_THERAPY_RESULT^MDC Episodes Episode Average Atrial Rate ^MDT_EPISODES_EPISODE_AVERAGEATRIALRATE^MDT {beats}/min^heartbeats per minute^mdc Episodes Episode Average Ventricular Rate 00000^MDT_EPISODES_EPISODE_ AVERAGEVENTRICLERATE^MDT {beats}/min^heartbeats per minute^mdc Episodes Episode Maximum Atrial Rate 0000^MDT_EPISODES_EPISODE_MAIMUMATRIALRATE^MDT {beats}/min^heartbeats per minute^mdc Episodes Episode Maximum Ventricular Rate 00002^MDT_EPISODES_EPISODE_ MAIMUMVENTRICLERATE^MDT {beats}/min^heartbeats per minute^mdc
194 92 Connectivity Guide Paceart Integration Paceart parameter type OB-2 OB-3 OB-4 OB-6 Episodes Episode Activity at Onset 00003^MDT_EPISODES_EPISODE_ACTIVITYATONSET^MDT Episodes Episode Data Name String ^MDT_EPISODES_EPISODE_ETENDEDDATA_NAME^MDT.[m] Episodes Episode Data Value 00005^MDT_EPISODES_EPISODE_ETENDEDDATA_VALUE^MDT.[m] Outbound OB Observation Message Segments Paceart parameter type OB-2 OB-3 OB-4 OB-6 Observation Blood Pressure String ^MDT_OBSERVATIONS_BLOODPRESSURE^MDT Observation Weight String ^MDT_OBSERVATIONS_WEIGHT^MDT Observation Height String ^MDT_OBSERVATIONS_HEIGHT^MDT Observation Body Mass Index String ^MDT_OBSERVATIONS_BMI^MDT Observation Arrhythmia Symptoms String ^MDT_OBSERVATIONS_ARRHYTHMIA_SYMPTOMS^MDT Observation Arrhythmia String ^MDT_OBSERVATIONS_ARRHYTHMIA_LOCATION^MDT Observation Arrhythmia Activity String ^MDT_OBSERVATIONS_ARRHYTHMIA_ACTIVITY^MDT Observation Arrhythmia Findings String ^MDT_OBSERVATIONS_ARRHYTHMIA_FINDINGS^MDT Outbound OB Evaluation Message Segments Paceart parameter type OB-2 OB-3 OB-4 OB-6 Evaluation Dependency 00028^MDT_EVALUATION_DEPENDENCY^MDT Evaluation Rhythm 00029^MDT_EVALUATION_RHYTHM^MDT Evaluation Observed Bradycardia Left Ventricle Sensing Assessment 00030^MDT_EVALUATION_LV_THRESHOLD_SENSING^MDT
195 Connectivity Guide Paceart Integration 93 Paceart parameter type OB-2 OB-3 OB-4 OB-6 Evaluation Observed Bradycardia Left Ventricle Capture Assessment 0003^MDT_EVALUATION_LV_THRESHOLD_CAPTURE^MDT Evaluation Observed Bradycardia Right Atrium Sensing Assessment 00032^MDT_EVALUATION_RA_THRESHOLD_SENSING^MDT Evaluation Observed Bradycardia Right Atrium Capture Assessment 00033^MDT_EVALUATION_RA_THRESHOLD_CAPTURE^MDT Evaluation Observed Bradycardia Right Ventricle Sensing Assessment 00034^MDT_EVALUATION_RV_THRESHOLD_SENSING^MDT Evaluation Observed Bradycardia Right Ventricle Capture Assessment 00035^MDT_EVALUATION_RV_THRESHOLD_CAPTURE^MDT Comment String ^MDT_EVALUATION_BRADYCOMMENT^MDT Comment String ^MDT_EVALUATION_TACHYCOMMENT^MDT Comment String ^MDT_EVALUATION_EPISODESCOMMENT^MDT Comment String ^MDT_EVALUATION_MISCELLANEOUSCOMMENT^MDT Outbound OB Phone Message Segments Paceart parameter type OB-2 OB-3 OB-4 OB-6 Phone Note Caller String ^MDT_PHONE_CALLER^MDT Phone Note Staff String ^MDT_PHONE_AFF^MDT Phone Note Reason String ^MDT_PHONE_REASON^MDT Outbound OB Miscellaneous Message Segments Paceart parameter type OB-2 OB-3 OB-4 OB-6 Description String ^MDT_MISCELLANEOUS_DESCRIPTION^MDT Outbound Messages Paceart Schema 6.0 Paceart integrates with the HL7 protocol for outgoing messages from Paceart to external systems by mapping a Paceart parameter and parameter type to HL7 values. This section describes outbound message mapping from Paceart schema 6.0. Mainspring Data Express can send event and device information to other systems. This is done using the HL7 observation reporting message. Paceart can generate an unsolicited transmission of an observation message for any Paceart encounter. A user can use the export function in Paceart to send the current information to other systems in an HL7 message. The observation reporting message will contain patient demographic information as well as observations related to device and encounter information. The ORU-R0 message transmits observations and results.
196 94 Connectivity Guide Paceart Integration Table : Supported HL7 ORU Triggers HL7 Message ORU^R0 Paceart Request Transmission Data Paceart Request Transmission Data Description Sends transmission data from one system to another system. The embedded PDF binary object will be sent in a single OB segment. The segment's data type (OB-2) will be ED (encapsulated data). The value field (OB-5) will be a multiple component field with the following layout. Component OB-5. OB-5.2 OB-5.3 OB-5.4 OB-5.5 Component Name Source Application of Data Data Subtype Encoding Data Value Paceart Application PostScript Base64 {Base64 encoded data stream of the PDF document} Example Segment: OB 5 ED RPT-000^Paceart PDF Embedded Paceart^Application^PostScript^Base64^JVBERi0xLjI {a lot more data} Outbound MSH Message Segments The HL7 MSH segment is present in every HL7 message type and defines the message's source, purpose, destination, and certain syntax specifics like delimiters (separator characters) and character sets. Source of Data or Literal Value ^~\& OutboundSendingApplicationNamespaceID OutboundSendingApplicationUniversalID OutboundSendingApplicationUniversalID OutboundSendingFacilityNamespaceID OutboundSendingFacilityUniversalID OutboundSendingFacilityUniversalID OutboundReceivingApplicationNamespaceID OutboundReceivingApplicationUniversalID OutboundReceivingApplicationUniversalID OutboundReceivingFacilityNamespaceID OutboundReceivingFacilityUniversalID OutboundReceivingFacilityUniversalID Field MSH- MSH-2 MSH-3 MSH-3 MSH-3 MSH-4 MSH-4 MSH-4 MSH-5 MSH-5 MSH-5 MSH-6 MSH-6 MSH-6 Component
197 Connectivity Guide Paceart Integration 95 Source of Data or Literal Value ORU R0 OutboundProcessingID OutboundProcessingIDMode OutboundHL7Version Field MSH-7 MSH-9 MSH-9 MSH-0 MSH- MSH- MSH-2 Component 2 2 Outbound PID Message Segments The PID (Patient Identification) segment provides important identification information about the patient and is used as the primary means of communicating the identifying and demographic information about a patient between systems. Paceart parameter Field Component Occurrence Patient ID Value PID Patient Last Name PID-5 Patient First Name PID-5 2 Patient Middle Initial String PID-5 3 Patient Birth Date PID-7 Patient Gender PID-8 Patient Address Line PID- Patient Address Line 2 PID- 2 Patient Address City PID- 3 Patient Address State String 0 PID- 4 Patient Address Postal Code String 0 PID- 5 Patient Address Country PID- 6 Patient Phone Number String 20 PID-3 Patient Address String 00 PID-3 4 Patient Fax Number String 20 PID-4 Outbound PV Message Segments The PV (Patient Visit) segment is used by registration applications to communicate information on a visit-specific basis. Paceart parameter Field Component Sub-Component Occurrence Patient Status String PV-2 Visit ID PV-9
198 96 Connectivity Guide Paceart Integration Outbound OBR Message Segments The OBR (Observation Request) segment transmits information about an exam, diagnostic study/observation, or assessment that is specific to an order or result. Paceart parameter Field Component Sub-Component Occurrence Key String 32 OBR-3 OBR-4 OBR-4 2 Date and Time OBR-7 Provider Code String 6 OBR-6 Provider Last Name OBR-6 2 Provider First Name OBR-6 3 Provider Middle Initial String OBR-6 4 Provider Credentials String 20 OBR-6 7 Date and Time OBR-22 Provider Code String 6 OBR-28 Provider Last Name OBR-28 2 Provider First Name OBR-28 3 Provider Middle Initial String OBR-28 4 Provider Credentials String 20 OBR-28 7 Device Observation Device and evaluation data is represented in an HL7 ORU^R0 message as defined above. Each message contains one or more OBR segments with related attribute data represented in a series of OB segments. OBR:4 Coded Elements The OBR:4 segment maps the Paceart value to the IDCO Profile value. The items below identify the referenced Universal Service Identifiers. Paceart value INCLINIC PROGRAMMING REMOTE TTM IMPLANT PHONENOTE MISC OBR: OBR:4.2 MDC_IDC SESS_TYPE_InClinic MDC_IDC SESS_TYPE_Other MDC_IDC SESS_TYPE_Remote MDC_IDC SESS_TYPE_Other MDC_IDC SESS_TYPE_Implant MDC_IDC SESS_TYPE_Other MDC_IDC SESS_TYPE_ Other
199 Connectivity Guide Paceart Integration 97 Outbound OB:3 Message Segments The identifier coding system referenced in OB:3 was developed by Medtronic specifically for the Paceart System outbound observation messaging. The name of the coding system component has been omitted from the coded element data because the Medtronic coding system is assumed throughout all ORU^R0 outbound messages from schema 6.0. Device Observation OB Applies to: OB:3. OB:3.2 OB:2 Length Transmitter Pacemaker ICD Lead Adapter DEV-000 CE 50 DEV-0002 Manufacturer 50 DEV-0003 Manufacturer Commentary L * DEV-0004 Model 50 DEV-0005 Serial Number 20 DEV-0006 Implant Date DT 8 DEV-0007 Chamber 60 DEV DEV-0009 Lead - Adaptor 50 DEV-000 Polarity 50 DEV-00 Access 50 DEV-002 Connect 20 DEV-003 Pacing ID DEV-004 Pri. Implanting Physician CN 60 DEV-005 Sec. Implanting Physician CN 60 DEV-006 Abandon Date DT 8 DEV-007 Partial Explant Date DT 8 DEV-008 Explant Date DT 8 DEV-009 Patient Commentary L * DEV-0020 Bi-Ventricular ID DEV-002 Remote Follow-up Enabled ID DEV-0022 Alert L * DEV-0023 Warranty 6 DEV-0024 BOL Characteristics 00 DEV-0025 EOL Characteristics 00
200 98 Connectivity Guide Paceart Integration Applies to: OB:3. OB:3.2 OB:2 Length Transmitter Pacemaker ICD Lead Adapter DEV-0026 EOL Charge Time 2 DEV-0027 EOL Voltage 2 DEV-0028 ERT Charge Time 2 DEV-0029 ERT Voltage 2 DEV-0030 Energy Units DEV-003 Date Given DT 8 DEV-0032 Acquisition Speed 0 DEV-0033 Transmission Format 25 DEV-0034 Default Gain 2 DEV-0035 Abandoning Physician CN 80 DEV-0036 Partially Explanting Physician CN 80 DEV-0037 Explanting Physician CN 80 L * = Field can contain over 3000 characters. Arrhythmia Observation Identifiers - Arrhythmia OB:3. OB:3.2 OB:2 Length OB:6 TTM Clinic ARR-000 Date of event TS 4 ARR-0002 Event type 0 ARR-0003 CardioVoice ID ARR-0004 Operator 50 ARR-0005 Event Commentary L * ARR-0006 Patient 78 ARR-0007 Patient Activity 78 ARR-0008 Findings of Test 200 ARR-0009 Minimum Rate 4 bpm ARR-000 Maximum Rate 4 bpm ARR-00 PR interval at minimum rate 4 sec ARR-002 PR interval at maximum rate 4 sec ARR-003 QRS interval at minimum rate 4 sec
201 Connectivity Guide Paceart Integration 99 OB:3. OB:3.2 OB:2 Length OB:6 TTM Clinic ARR-004 QRS interval at maximum rate 4 sec ARR-005 QT interval at minimum rate 4 sec ARR-006 QT interval at maximum rate 4 sec L * = Field can contain over 3000 characters. Device Evaluation Observation Identifiers - Pacemaker OB:3.0 OB:3.2 OB:2 Length OB:6 TTM Clinic Remote Implant EVAL-000 Date of event TS 4 EVAL-0002 Event 0 EVAL-0003 CardioVoice ID EVAL-0004 Operator 50 EVAL-0005 Rmt Folloup Svc Name 00 EVAL-0006 Transmission 50 EVAL-0007 Event Commentary 255 EVAL-0008 Demand Interval 0 ms EVAL-0009 Demand AV Delay 0 ms EVAL-000 Magnet Interval 0 ms EVAL-00 Magnet AV Delay 0 ms EVAL-002 Magnet Atrial Pulse Duration 0 ms EVAL-003 Magnet Vent Pulse Duration 0 ms EVAL-004 Atrial Capture EVAL-005 Atrial Sensing EVAL-006 Ventricular Capture EVAL-007 Ventricular Sensing EVAL-008 Blood Pressure 25 EVAL-0020 Rhythm 75 EVAL-0022 Eval Commentary L * L * = Field can contain over 3000 characters. Device Evaluation Observation Identifiers - ICD OB:3.0 OB:3.2 OB:2 Length OB:6 Clinic Remote Implant EVAL-000 Date of event TS 4
202 200 Connectivity Guide Paceart Integration OB:3.0 OB:3.2 OB:2 Length OB:6 Clinic Remote Implant EVAL-0002 Event 0 EVAL-0003 CardioVoice ID EVAL-0004 Operator 50 EVAL-0005 Rmt Folloup Svc Name EVAL-0006 Transmission EVAL-0007 Event Commentary 255 EVAL-004 Atrial Capture EVAL-005 Atrial Sensing EVAL-006 Ventricular Capture EVAL-007 Ventricular Sensing EVAL-008 Blood Pressure 25 EVAL-009 Symptoms 75 EVAL-0020 Rhythm 75 EVAL-0022 Eval Commentary L * L * = Field can contain over 3000 characters. Device Evaluation Observation Identifiers - Arrhythmia OB:3.0 OB:3.2 OB:2 Length OB:6 TTM Clinic EVAL-000 Date of event TS 4 EVAL-0002 Event 0 EVAL-0003 CardioVoice ID EVAL-0004 Operator 50 EVAL-0007 Event Commentary 255 EVAL-009 Symptoms 75 EVAL-0022 Eval Commentary L * L * = Field can contain over 3000 characters. Device Evaluation Observation Identifiers - Programming and Miscellaneous OB:3.0 OB:3.2 OB:2 Length OB:6 Programming Miscelaneous EVAL-000 Date of event TS 4 EVAL-0003 CardioVoice ID EVAL-0004 Operator 50 EVAL-0007 Event Commentary 255 EVAL-002 Description 255 EVAL-0022 Eval Commentary L *
203 Connectivity Guide Paceart Integration 20 L * = Field can contain over 3000 characters. Identifiers Telemetry Observation Identifiers Pacemaker ICD OB:3. OB:3.2 OB:2 Length OB:6 Clinic Remote Implant Clinic Remote Implant TEL-000 Percent Pacing Atrial 0 TEL-0002 Percent Pacing Ventricular 0 TEL-0003 Min. Volt During Charging 7 v TEL-0004 Test Charge Time 0 sec TEL-0005 Test Charge Energy 0 j,v TEL-0006 Last High Voltage Energy 20 v TEL-0007 Last Hi Volt Chrg Time 0 sec TEL-0008 Lead Impedance Atrial 5 ohm TEL-0009 Lead Impedance Left Vent 5 ohm TEL-000 Lead Impedance Right Vent 5 ohm TEL-00 Lead Impedance High Volt 5 ohm TEL-002 AutoGain 0 TEL-003 Battery Voltage 7 v TEL-004 Battery Impedance 7 ohm Example: OB 0 TEL-0004^Test Charge Time 7.9 s OB TEL-0005^Test Charge Energy 35 j OB 2 TEL-0006^Last High Voltage Energy 35 v OB 3 TEL-0007^Last Hi Volt Chrg Time 8.45 s OB 4 TEL-0008^Lead Impedance Atrial 42 ohm OB 5 TEL-000^Lead Impedance Right Vent 440 ohm OB 6 TEL-00^Lead Impedance High Volt 202 ohm OB 7 TEL-003^Battery Voltage 2.99 v
204 202 Connectivity Guide Paceart Integration Lead Observation Identifiers Pacemaker OB:3. Class OB:3.2 OB:2 Length OB:6 Clinic Remote Implant LEAD-000 Lead Chamber 2 LEAD-0002 Lead Bipolar Impedance 5 ohm LEAD-0003 Lead Unipolar Impedance 5 ohm LEAD-0004 Lead Evoked Response 7 LEAD-0005 Lead Polarization 7 Example: OB 5 LEAD-000^Chamber RA OB 6 LEAD-0002^Bipolar Impedance 450 ohm OB 7 LEAD-000^Chamber 2 RV OB 8 LEAD-0002^Bipolar Impedance ohm Threshold Observation Sensing Identifiers Pacemaker ICD OB:3. OB:3.2 OB:2 Length OB:6 Clinic Remote Implant Clinic Remote Implant TSEN-000 Chamber 2 TSEN-0002 Amplitude 0 mv TSEN-0003 Polarity TSEN-0004 Use for Graphing ID TSEN-0005 Example: OB 9 TSEN-000^Chamber RA OB 20 TSEN-0002^Amplitude millivolts 5 mv OB 2 TSEN-0003^Polarity B OB 22 ID TSEN-0004^Use For Graphing Y
205 Connectivity Guide Paceart Integration 203 Threshold Observation Capture Identifiers Pacemaker ICD OB:3. OB:3.2 OB:2 Length OB:6 Clinic Remote Implant Clinic Remote Implant TCAP-000 Chamber 2 TCAP-0002 Amplitude 0 v TCAP-0003 Duration 0 ms TCAP-0004 Polarity TCAP-0005 Use for Graphing ID TCAP Example: OB 26 TCAP-000^Chamber RA OB 27 TCAP-0002^Amplitude v OB 28 TCAP-0003^Duration 0. OB 29 TCAP-0004^Polarity B OB 30 ID TCAP-0005^Use For Graphing N Detections and Treatments Observation Identifiers ICD OB:3. OB:3.2 OB:2 Length OB:6 Clinic Remote Implant DT-000 Ventricular Fibrillation 0 DT-0002 Fast Vent. 0 DT-0003 Slow Vent. 0 DT-0004 Very Slow Vent. Tachy. 0 DT-0005 Atrial Fibrillation 0 DT-0006 Atrial Flutter 0 DT-0007 Atrial 0 DT-0008 Ext. HiRate Sus. Detect 0 DT-0009 Non Sus. Vent. Detect 6 DT-000 Non Sus. Atrial Detect 6 DT-00 AMS Episodes 0 DT-002 s Delivered Vent. 0 DT-003 s Delivered Atrial 0
206 204 Connectivity Guide Paceart Integration ICD OB:3. OB:3.2 OB:2 Length OB:6 Clinic Remote Implant DT-004 s Aborted Vent. 0 DT-005 s Aborted Atrial 0 DT-006 ATP Episodes Ventricular 0 DT-007 ATP Episodes Atrial 0 DT-008 Percent Pacing Ventricular 0 pct DT-009 Percent Pacing Atrial 0 pct Example: OB 36 DT-008^Percent Pacing Ventricular 99 pct OB 37 DT-009^Percent Pacing Atrial 99 pct Telemetry Totals Observation Identifiers ICD OB:3. OB:3.2 OB:2 Length OB:6 Clinic Remote Implant TOT-000 s Delivered 0 TOT-0002 s Aborted 0 TOT-0003 Test Changes 20 TOT-0004 Total Changes 20 TOT-0005 Cumulative Charge Time 5 sec. TOT-0006 Counters Cleared Date TS 26 TOT-0007 Charges (50-200) 5 TOT-0008 Charges ( ) 5 TOT-0009 Charges ( ) 5 TOT-000 Charges ( ) 5 Example: OB 2 TOT-000^s Delivered 2 OB 22 TOT-0004^Total Charges 3 OB 23 TS TOT-0006^Counters Cleared Date
207 Connectivity Guide Paceart Integration 205 ICD Episode Observation Identifiers ICD OB:3. OB:3.2 OB:2 Length OB:6 Clinic Remote Implant EPH-000 Last Interrogated TS 26 EPH-0002 Last Cleared Date TS 26 ICD OB:3. OB:3.2 OB:2 Length OB:6 Clinic Remote Implant EP-000 Episode 2 EP-0002 EpisodeID 6 ICD OB:3. OB:3.2 OB:2 Length OB:6 Clinic Remote Implant EPD-000 Field Name 50 EPD-0002 Field Value 50 Example: OB 39 TS EPH-000^Last Interrogated 2005 OB 40 TS EPH-0002^Last Cleared Date 2004 OB 4 EP-000^Episode. VT/VF OB 42 EP-0002^EpisodeID. 7893t-0998 OB 43 EPD-000^Field Name.. <field name> OB 44 EPD-0002^Field Value.. <field value> Brady Programming Observation Identifiers Pacemaker ICD OB:3. OB:3.2 OB:2 Length OB:6 Clinic Remote Implant Clinic Remote Implant Programming BRDY-000 Pacing Mode 5 BRDY-0002 Lower Rate 5 bpm BRDY-0003 Tracking Rate 5 bpm BRDY-0004 Max Sensor Rate 5 bpm
208 206 Connectivity Guide Paceart Integration Pacemaker ICD OB:3. OB:3.2 OB:2 Length OB:6 Clinic Remote Implant Clinic Remote Implant Programming BRDY-0005 Hysteresis Rate 0 bpm BRDY-0006 Sleep Rate 5 bpm BRDY-0007 PMT Intervention 20 BRDY-0008 PVC Intervention 20 BRDY-0009 Dependancy 0 BRDY-000 Notes 50 Example: OB 35 BRDY-000^Pacing Mode DDDR OB 36 BRDY-0002^Lower Rate 70 bpm OB 37 BRDY-0003^Tracking Rate 40 bpm OB 38 BRDY-0004^Max Sensor Rate 20 bpm Brady Sensing Observation Identifiers Pacemaker ICD OB:3. OB:3.2 OB:2 Length OB:6 Clinic Remote Implant Clinic Remote Implant BSEN-000 Chamber 2 BSEN-0002 Amplitude 5 mv BSEN-0003 Polarity BSEN-0004 Refractory Period 5 ms BSEN-0005 Blanking Period 5 ms Example: OB 39 BSEN-000^Chamber RA OB 40 BSEN-0002^Amplitude.0 mv OB 4 BSEN-0004^Refractory Period 300 ms Brady Pacing Observation Identifiers Pacemaker ICD OB:3. OB:3.2 OB:2 Length OB:6 Clinic Remote Implant Clinic Remote Implant BPAC-000 Chamber 2
209 Connectivity Guide Paceart Integration 207 Pacemaker ICD OB:3. OB:3.2 OB:2 Length OB:6 Clinic Remote Implant Clinic Remote Implant BPAC-0002 Amplitude 5 v BPAC-0003 Pulse Width 5 ms BPAC-0004 Polarity Example: OB 45 BPAC-000^Chamber RA OB 46 BPAC-0002^Amplitude 3.8 v OB 47 BPAC-0003^Pulse Width 0.4 ms Brady Rate Modulation Observation Identifiers Pacemaker ICD OB:3. OB:3.2 OB:2 Length OB:6 Clinic Remote Implant Clinic Remote Implant Programming BMOD-000 Threshold 5 BMOD-0002 Slope 5 BMOD-0003 Acceleration Reaction 5 BMOD-0004 Deceleration Recovery 5 BMOD-0005 ADL Rate 5 bpm Example: OB 57 BMOD-000^Threshold Medium OB 58 BMOD-0002^Slope 7 OB 59 BMOD-0003^Accleration Reaction 30 min OB 60 BMOD-0004^Decleration Recovery 5 sec Brady AV Delay Observation Identifiers Pacemaker ICD OB:3. OB:3.2 OB:2 Length OB:6 Clinic Remote Implant Clinic Remote Implant Programming BAVD-000 Sensed AV Delay 5 ms BAVD-0002 Paced AV Delay 5 ms BAVD-0003 Adaptive AV Delay Status 8
210 208 Connectivity Guide Paceart Integration Pacemaker ICD OB:3. OB:3.2 OB:2 Length OB:6 Clinic Remote Implant Clinic Remote Implant Programming BAVD-0004 Adaptive Rate Minimum 8 bpm BAVD-0005 Adaptive Rate Maximum 8 bpm BAVD-0006 Adaptive Sensed Minimum 8 ms BAVD-0007 Adaptive Paced Minimum 8 ms BAVD-0008 VV Delay 8 ms Brady AMS Observation Identifiers Pacemaker ICD OB:3. OB:3.2 OB:2 Length OB:6 Clinic Remote Implant Clinic Remote Implant Programming BAMS-000 Rate 5 bpm BAMS-0002 Duration 0 ms BAMS-0003 Fallback Rate 5 bpm Example: OB 58 BAMS-000^Rate 70 bpm Tachy Observation Identifiers ICD OB:3. OB:3.2 OB:2 Length OB:6 Clinic Remote Implant Programming TACH-000 Detection Status Ventricular 50 TACH-0002 Detection Status Atrial 50 TACH-0003 Status Ventricular 25 TACH-0004 Status Atrial 25 TACH-0005 Commentary L * L * = Field can contain over 3000 characters.
211 Connectivity Guide Paceart Integration 209 Example: OB 8 TACH-000^Detection Status Ventricular -ZONE OB 9 TACH-0003^ Status Ventricular 5.9 Tachy VF Zone Observation Identifiers ICD OB:3. OB:3.2 OB:2 Length OB:6 Clinic Remote Implant Programming TVF-000 Zone 25 TVF-0002 Configuration 25 TVF-0003 Detection Interval 0 ms TVF-0004 Detection Duration 25 TVF-0005 Redetection Duration 25 TVF-0006 Committed ID Example: OB 29 TVF-0002^Detection Interval 343 ms Tachy VFZ Observation Identifiers ICD OB:3. OB:3.2 OB:2 Length OB:6 Clinic Remote Implant Programming TVFS-000 Number 3 TVFS-0002 Status ID TVFS-0003 s Energy 0 v, j TVFS-0004 Waveform 20 TVFS-0005 Pulse Width Positive 0 ms TVFS-0006 Pulse Width Negative 0 ms TVFS TVFS-0008 Cardioversion Delay 0 ms TVFS-0009 Committed ID
212 20 Connectivity Guide Paceart Integration Example: OB 63 TVFS-000^ Number OB 64 ID TVFS-0002^Status N OB 65 TVFS-0003^ Energy 0.4 OB 66 TVFS-0004^Waveform Biphasic OB 67 TVFS-0007^ A>B Tachy Zone Observation Identifiers ICD OB:3. OB:3.2 OB:2 Length OB:6 Clinic Remote Implant Programming TZON-000 Zone 8 TZON-0002 Configuration 25 TZON-0003 Detection Interval 0 ms TZON-0004 Detection Duration 25 TZON-0005 Redetection Duration 25 TZON-0006 Commentary 6 TZON-0007 EHR SRD Rate * 0 bpm TZON-0008 EHR SRD Duration 0 ms TZON-0009 Sudden Onset Criteria 5 ms or pct TZON-000 Rate Stability Criteria 5 ms TZON-00 QRS Morphology Criteria 25 * = Field is labeled but will send string data. Example: OB 23 TZON-000^ Configuration Disabled OB 24 TZON-0002^Detection Interval 350 OB 25 TZON-0007^EHR SRD Duration 2 min OB 26 TZON-0009^Rate Stability Criteria 30 OB 27 TZON-00^Zone FastVT Tachy Z ATP Observation Identifiers ICD OB:3. OB:3.2 OB:2 Length OB:6 Clinic Remote Implant Programming TZAT-000 Number 3 TZAT-0002 Status ID
213 Connectivity Guide Paceart Integration 2 ICD OB:3. OB:3.2 OB:2 Length OB:6 Clinic Remote Implant Programming TZAT TZAT-0004 Stimuli Count 0 TZAT-0005 Coupling Interval 0 ms, pct TZAT-0006 Coupling Interval Decrement 0 ms, pct TZAT-0007 Burst Cycle Length 0 ms, pct TZAT-0008 SS2 Ramp 0 pct TZAT-0009 S2SN Ramp 0 pct TZAT-000 Ramp Decrement 0 ms TZAT-00 Interval Decrement 0 ms TZAT-002 Minimum Burst Cycle Length 0 ms TZAT-003 Number Of Sequences 0 TZAT-004 Maximum Number Of Pulses 0 TZAT-005 Pulse Increment 0 TZAT-006 Scan Decrement 0 ms TZAT-007 Sequence 0 TZAT-008 Smart Mode ID TZAT-009 Output Amplitude 0 v TZAT-0020 Output Duration 0 ms Example: OB 03 TZAT-000^ Number 2 OB 04 ID TZAT-0002^Status N OB 05 TZAT-0003^ Ramp OB 06 TZAT-0004^Stimuli Count 8 OB 07 TZAT-0005^Coupling Interval 9 OB 08 TZAT-00^Interval Decrement 0 ms OB 09 TZAT-002^Minimum Burst Cycle Length 200 ms OB 0 TZAT-003^Number Of Sequences 3 OB TZAT-009^Output Amplitude 8 v OB 2 TZAT-0020^Output Duration.6 ms
214 22 Connectivity Guide Paceart Integration Tachy Z Observation Identifiers ICD OB:3. OB:3.2 OB:2 Length OB:6 Clinic Remote Implant Programming TZ-000 Number TZ-0002 Status ID TZ-0003 Energy 0 v, j TZ-0004 Waveform 20 TZ-0005 Pulse Width Positive 0 ms TZ-0006 Pulse Width Negative 0 ms TZ TZ-0008 Cardioversion Delay 0 ms TZ-0009 Committed ID 0 Example: OB 203 TZ-000^ Number 6 OB 204 ID TZ-0002^Status N OB 205 TZ-0003^ Energy 0.4 OB 206 TZ-0004^Waveform Biphasic OB 207 TZ-0007^ A>B* Troubleshooting Paceart HL7 Integration Troubleshooting Paceart HL7 integration problems Paceart Verify that the Paceart database has a Mainspring Data Express user. Verify the Paceart database password associated with the Mainspring Data Express user. Verify that the Paceart patient record has a date of birth and a valid patient ID number. Mainspring Data Express Verify that the Mainspring Data Express software and features were properly installed and configured. Verify that the Connected Systems Gateway service was started. Programmer Acquisition service cannot start Event Log message If in the Event Log for the Programmer Acquisition service you receive an error message that says "Programmer Acquisition service cannot start", you need to change the Corepoint Integration Engine port value.
215 Connectivity Guide Paceart Integration 23. Click Start > Programs > Corepoint Health > Corepoint Integration Engine > Corepoint Integration Engine - Configuration. 2. Click Service > Corepoint Integration Engine Monitor Service Configuration. The Corepoint Integration Engine Monitor Service Configuration window is displayed. 3. Change the port value. 4. Click OK. Local Data Interface The Local Data Interface allows you to configure the service that receives patient session data transmitted from local sources, such as a programmer or LATITUDE. You can start and stop the service, configure advanced options, and enable or disable transmissions from enabled sources. Local Data Interface Extended Configurations This table explains the fields on the LDI Extended Configurations window. Field name Manufacturer Name Username Password Explanation The manufacturer name of the data provided by a specific system. For example, "Medtronic". The type of data provided by a specific system. The default value is "InClinic". The username for a user-defined local data interface extended configuration. The password for a user-defined local data interface extended configuration. Local Data Interface certificate installation The digital certificate allows a secure connection to be established between a data import source and Paceart. You must complete the certificate installation before you can import data from other sources. You will generate a certificate request that you will to Paceart Technical Support. Then Technical Support will you back the certificate file that you will import into your system and install. If you have questions please call Paceart Technical Support. Installing the Certificate. On the Local Data Interface tab, click Generate Request. The Export Certificate Request window is displayed. 2. In the Customer Information section, enter your information in the following required fields: Organization State or Province Country 3. In the Contact Information section, enter your information in the following required field: - must be in standard format (the certificate will be ed to this address)
216 24 Connectivity Guide Paceart Integration 4. From the Server Addressing section, select how you would like the data import source to address the Local Data Interface. Select the check box next to Host Name or IP Address. 5. Click Export Certificate Request to a File. 6. Select the location where you would like to save the certificate request file. You must save to a location that can be accessed by a workstation or computer that has . The default file location is C:\PaceartGatewayCertificateRequest.McertReq. 7. Once the file has been successfully exported, click OK. 8. Send an with the exported certificate request file to Paceart Technical Support at [email protected]. 9. Technical Support will then send the certificate file to the address you specified. Note: Some days may elapse before you receive the certificate. The certificate is usually sent out within one business day. 0. Save the certificate file to a location that is accessible from the Paceart computer. The default filename is C:\PaceartGatewayCertificate.MCert.. Click Install Certificate. 2. Find and select the file using the standard Windows dialog and click Open. 3. If you have completed the installation successfully, the Digital Certificate section will display Digital Certificate has been installed. If you receive an error message, call Paceart Technical Support. Enabling a data import source You must install the certificate before you can enable a source for data import.. Click on the source ID listed in the Available for Data Import table to select it. 2. Click Add. 3. The source ID will now be in the Enabled for Data Import table. 4. Click OK for the changes to take effect. This source is now able to import data to Paceart. Remote Data Interface The Remote Data Interface allows you to configure the service that imports patient session data from remote sources, such as the Medtronic CareLink Network. You can start and stop the service, specify the polling interval, select the service's auto start options, and configure the login information for remote follow-up services. Configuring Remote Data Interface. To start Mainspring Data Express, go to Start > Programs > Medtronic Mainspring Data Express > Medtronic Mainspring Data Express. 2. In the Medtronic Mainspring Data Express window, select Remote Data Interface and click Configurations.
217 Connectivity Guide Paceart Integration 25 The Paceart Integration configuration window is displayed. 3. On the Remote Data Interface tab enter the applicable values for your implementation. Refer to the Remote Data Interface Configuration Values table for more explanation on the fields. 4. If you receive data from more than one remote system, you must have a separate Remote Data Interface configuration for each system. Click Add to create additional configurations for additional remote systems. You can create up to 5 configurations. 5. Click OK. Remote Data Interface Configuration Values This table explains the fields on the Remote Data Interface configuration tab. Field name Explanation Carelink System Account Name System Account Access Code Data Service Data Service Site Manufacturer Name Application ID Clinic Request Start Date The account name used to connect to the CareLink system. This account name is created and configured on the External System Accounts tab on the CareLink website. The authorization code used to connect to the CareLink website. This authorization code is configured on the External System Accounts tab on the CareLink website. The name of the service. The default value is "Endpoint_CSA_basicHttpsBinding". The URL to access the data service(s) of a specific system. For CareLink, this is referred to as the Transmission Gateway Service. The manufacturer name of the data provided by a specific system. For CareLink, this value is "Medtronic". The name of the external system. For CareLink, this value is "CareLink". The type of data provided by a specific system. For CareLink, this value is "Remote". The value indicating the start date for requests from the external system.
218 26 Connectivity Guide Paceart Integration Enabling remote data acquisition in Paceart After you have configured Remote Data Interface for Mainspring Data Express, you need to enable remote data acquisition in Paceart.. Double-click on the Medtronic Paceart Optima icon on your desktop. 2. Log in to Paceart. 3. Click Administration > Connectivity. 4. Click the CareLink Remote Acquisition tab. 5. Click Edit. The CareLink Remote Acquisition dialog is displayed. 6. Select Active to enable CareLink remote data acquisition. 7. Select Nightly Active to enable nightly CareLink remote data acquisition. This option is only available if you have selected Active. 8. Click Save. Paceart will now be enabled for remote data acquisition.
219 Connectivity Guide CareLink Integration 27 CareLink Integration The CareLink Integration section of Mainspring Data Express has the following features: Report Export: Saves CareLink reports to a network location. Mainspring Report Export Reports can be exported from CareLink to an external system like your clinic's Electronic Medical Records (EMR) system. When the report export feature is enabled, you can use a default file naming format, or customize the filename format by adding an additional field. You must have full administrative privileges in CareLink to edit the filename format. To export reports, Mainspring Data Express must be installed and configured, and a CareLink Network Connection between Mainspring Data Express and the CareLink Network must be established. There is a process to install and configure the Mainspring Report Export feature.. On the CareLink website, create an External System Account for Mainspring Data Express. You can customize the default file naming format if desired. 2. On your network, install and configure Mainspring Data Express. 3. Enable the Report Export feature in Mainspring Data Express. 4. On the CareLink website, export a report from CareLink and ensure that it arrives in the correct location. Mainspring Report Export Prerequisites on CareLink Before you configure Mainspring Report Export you must complete the following prerequisite: On the CareLink website on the Clinic Management > External System Accounts tab, create an External System Account for Mainspring Data Express. Enable the Report Export feature. You can customize the default file naming format if desired. Configuring Mainspring Report Export. To start Mainspring Data Express, go to Start > Programs > Medtronic Mainspring Data Express > Medtronic Mainspring Data Express. 2. In the Medtronic Mainspring Data Express window, select Medtronic Mainspring Report Export and click Configurations.
220 28 Connectivity Guide CareLink Integration The Medtronic Mainspring Report Export configuration window is displayed. 3. On the Configuration tab enter the applicable values for your CareLink implementation. Refer to the Mainspring Report Export Configuration Values table for more explanation on the fields. 4. If you have satellite clinics in CareLink you must have a separate Mainspring Report Export configuration for each clinic. Click Add to create additional configurations for other clinics. 5. Click OK.
221 Connectivity Guide CareLink Integration 29 Medtronic Mainspring Report Export Configuration Values This table explains the fields on the Medtronic Mainspring Report Export configuration window. Callout number 2 Field name Description Reporting Service Explanation An optional field for entering the name of your configuration. Limit 5 configurations. The name of the CareLink reporting service the adapter will use. The default is "Endpoint_CSA_basicHttpsBinding". 3 Reporting Service Site The path of the CareLink reporting service that the adapter will use. To connect in the US and Canada select " ReportExportGateway/ReportExportGateway.svc". To connect in Europe and Japan select " ReportExportGateway/ReportExportGateway.svc". 4 5 External System Account Name External System Account Authorization Code The account name used to connect to the CareLink system. This account name is created and configured on the External System Accounts tab on the CareLink website. The authorization code used to connect to the CareLink website. This authorization code is configured on the External System Accounts tab on the CareLink website.
222 220 Connectivity Guide CareLink Integration Callout number Field name Explanation 6 7 Document Folder Use Specified Credentials The file destination path where CareLink PDF reports are exported. On the CareLink website this is called the document folder. The file destination path can be specified as a UNC path (\\ComputerName\SharedFolder\Reports) or a mapped drive (z: \\computer\reports). Using a mapped drive allows you to use a shorter file name but the computer hosting Mainspring Data Express must have the network drive mapped to it. A "True" value indicates that the Windows Username and Password field values should be used as authentication credentials when accessing the destination path. A False value indicates that a username and password are not required to access the destination path. The default is "False" Username Password Overwrite Existing File(s) When Use Specified Credentials is "True", this is the Windows username that will be used when accessing the destination file system. The Windows username value should follow the UPN (User Principal Name) format username@domain. For example BSMITH@ENT. When Use Specified Credentials is "True", this is the password associated to the Windows Username that will be used when accessing the destination file system. A "True" value indicates that the adapter will overwrite an existing file with a new file of the same name. A "False" value indicates that the adapter will not overwrite an existing file with a new file of the same name. The default is "False". Minimum Available Disk Space The minimum amount of free space in MB on the destination file system required for the adapter to initialize. The default is "5" MB. Enabling and Verifying Mainspring Report Export After you install and configure Mainspring Report Export you need to enable the Report Export feature on the CareLink website.. Log into the CareLink website. 2. Click Manage My Clinic > Clinic Profile > External Systems Integration. 3. In the Report Export section, select Yes to enable report export. Note: You can configure the report filename. For more information on configuring the filename refer to the Editing Report Filename for Report Export topic in the CareLink online Help. 4. Click Save. 5. After you have enabled the feature, export a sample report from CareLink. 6. Browse to the documentation folder location and verify that the sample report was successfully exported.
223 Connectivity Guide CareLink Integration 22 Troubleshooting Mainspring Report Export Mainspring Data Express Verify that the Mainspring Data Express software prerequisites were installed or configured correctly. Verify that you selected the correct Reporting Service Site for your geography. Verify that the External System Account Name and External System Account Authorization Code match what was created in CareLink on the External System Accounts tab. Verify that you've selected True in the Use Specified Credentials field if the report destination requires you to enter a Windows username and password. Then verify that the Windows username and password were entered correctly in the Username and Password fields. Verify that the Connected Systems Gateway service was started. Mainspring Report Export on CareLink Verify that you created an External System Account in CareLink. Verify that the created External System Account was configured to include Report Export external system associations. Verify that Report Export was enabled on the External System Integration tab of the CareLink website. Verify that the Report Export file naming format was configured as desired.
224 222 Connectivity Guide Paceart ML Schema Paceart ML Schema The Paceart System exports files that conform to a Paceart proprietary schema definition. If you will be integrating the Paceart System to another system, you must write your integration into the Paceart ML schema. Paceart Optima uses ML schema version 7.0 but Paceart Optima also gives you the ability to export encounter xml data to older Paceart schema versions, such as version 6.0 used in the Paceart Get Connected III release. valid values BurstCycleLengthUnits CouplingIntervalUnits CouplingIntervalDecrementUnits EnergyUnits SuddenOnsetCriteriaUnits TestChargeEnergyUnits Units ms % ms % ms % J V ms % J V Export Episode Zone ATPSequence Values VT/VF SVT/N Mode Switch/AT/AF FastVT SlowVT VSlowVT AFib AFlutter ATach Decrement Increment
225 Connectivity Guide Paceart ML Schema 223 Export Values Dec./Inc. ATP Polarity BlankingPeriod SensePolarity PacePolarity Chamber Burst Burst+ ABurst+ Ramp Ramp+ A>B B>A Initial Reversed RV(+), Can(-) RV(-), Can(+) RV(+), SVC/Can(-) RV(-), SVC/Can(+) Unipolar Bipolar AfterCrossChamberSense AfterSameChamberSense AfterCrossChamberPace AfterSameChamberPace AfterSameChamberSenseOrPace AfterCrossChamberSenseOrPace B U D C R B U D T R RA LA
226 224 Connectivity Guide Paceart ML Schema Export Values RV LV Assessment LeadConnect LeadChamber RemoteFollowUpServiceName Sex TransmissionFormat Appointment Remote Status Y N D? - Pacemaker ICD Atrium Ventricle Medtronic CareLink Network LATITUDE Patient Management System St. Jude Medical Monitoring System BIOTRONIK Home Monitoring System monitoring service M F SingleLead CardGuard Instromedix Zymed Paceart3Lead Paceart6Lead Paceart7Lead PaceartEASI2Lead PaceartHeartAccess3500 TZMedical DelMarReynolds Braemar Processing Scheduled Error Complete
227 Connectivity Guide Paceart ML Schema 225 Export Values Missed Ignored Paceart ML export FileInformation This block is rooted at /Paceart/FileInformation/ in the ML output. Report Header @WorkstationID string[0] string[00] datetime string[50] string[50] ML Domain Mapping Paceart maps parameters to their defined Paths for standard Paceart ML. Session The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Session. Session Timestamp Session Initiation Session Reprogrammed Path /Timestamp /Initiation /Reprogrammed The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Session/Device. Session Device Session Device Manufacturer Session Device Model Session Device Serial Number Session Device Serial Number Regular Expression Path / /Manufacturer /Model /SerialNumber /SerialNumber_RegularExpression
228 226 Connectivity Guide Paceart ML Schema Session Device Firmware Version Session Device Ramware Version Session Device Ramware Description Path /FirmwareVersion /RamwareCollection/Version /RamwareCollection/Description The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Session/Instrument. Session Instrument Manufacturer Session Instrument Hardware Model Session Instrument Serial Number Session Instrument Software Model Session Instrument Software Version Path /Manufacturer /HardwareModel /SerialNumber /SoftwareModel /SoftwareVersion File Information The root path in the ML output for the following table is /PaceartML/FileInformation. ML Verison Path /SchemaVersion String 0 Patient Demographics The root path in the ML output for the following table is /PaceartML/PatientRecord. Patient Status Patient Remote Service Patient Comment Path /Status /RemoteFollowupService /Comment String String The root path in the ML output for the following table is /PaceartML/PatientRecord/Demographics. Patient Prefix Patient First Name Patient Middle Initial Patient Last Name Patient Suffix Path /Prefix /FirstName /MiddleName /LastName /Suffix String String 0
229 Connectivity Guide Paceart ML Schema 227 Patient Birth Date Patient Gender Patient Marital Status Patient Address Patient Language Path /DateOfBirth /Gender /MaritalStatus / /Language String 00 The root path in the ML output for the following table is /PaceartML/PatientRecord/Demographics/ OfCare. of Care Name of Care Address Line of Care Address Line 2 of Care Address City of Care Address State of Care Address Country of Care Address Postal Code of Care Abbreviation of Care Comment of Care Contact of Care Contact Name of Care Fax Number of Care Phone Number Path /Name /Line /Line2 /City /State /Country /ZipCode /Abbrevation /Comments /Contact /ContactName /FaxNumber /PhoneNumber String 0 String 0 String 20 String 255 String 00 String 00 String 20 String 20 The root path in the ML output for the following table is /PaceartML/PatientRecord/Demographics/ Addresses/Address. Patient Address Line Patient Address Line 2 Patient Address City Patient Address State Patient Address Country Patient Address Postal Code Path /Line /Line 2 /City /State /Country /ZipCode String 0 String 0 The root path in the ML output for the following table is /PaceartML/PatientRecord/Demographics/ Phones/Phone[IsDefault='true']. Patient Phone Number Path /Number String 20
230 228 Connectivity Guide Paceart ML Schema Patient Phone Number Phone Path / The root path in the ML output for the following table is /PaceartML/PatientRecord/Demographics/ Phones/Phone[IsDefault='false']. Patient Phone Number Other Patient Phone Number Other Phone Path /Number / String 20 The root path in the ML output for the following table is /PaceartML/PatientRecord/IDs/ID. Patient ID Description Patient ID Value Path / /Value The root path in the ML output for the following table is /PaceartML/PatientRecord/Codes/Code. Patient Code Name Patient Code Value Patient Code Name 2 Patient Code Value 2 Patient Code Name 3 Patient Code Value 3 Patient Code Name 4 Patient Code Value 4 Path / /Value / /Value / /Value / /Value String 6 String 6 String 6 String 6 Patient Diagnosis The root path in the ML output for the following table is /PaceartML/PatientRecord/Diagnoses/ PatientDiagnosis. Patient Diagnosis Status Patient Diagnosis Comments Patient Provider Related Device NA Path /IsActive /Comment /RelatedDevice /SortOrder String 255 Reference Only The root path in the ML output for the following table is /PaceartML/PatientRecord/Diagnoses/ PatientDiagnosis/Diagnosis. Diagnosis Description Diagnosis Code Path /Description /Code String 6
231 Connectivity Guide Paceart ML Schema 229 Diagnosis Comments Path /Comment String 00 Patient Providers The root path in the ML output for the following table is /PaceartML/PatientRecord/Providers/ PatientProvider. Patient Provider Patient Provider Comments Provider Last Name Provider First Name Provider Middle Initial Provider Address Provider Credentials Provider Bill Code Provider ID Provider NPI Provider SSN Provider UPIN Provider Comments Provider Pager PIN Provider CardioVoice ID Provider Code Pager Service Name Pager Service Name Pager Service Phone Pager Service Message Length Provider Address Line Provider Address Line 2 Provider Address City Provider Address State Provider Address Country Provider Address Postal Code Provider Phone Number Provider Fax Number Provider Specialty Path /Provider /Comment /Provider/LastName /Provider/FirstName /Provider/MiddleInitial /Provider/ /Provider/Credentials /Provider/BillCode /Provider/ProviderID /Provider/NPI /Provider/SSN /Provider/UPIN /Provider/Comments /Provider/PagerPin /Provider/CardioVoiceID /Provider/ProviderCode /Provider/PagerService/Name /Provider/PagerService/Description /Provider/PagerService/ PhoneNumber /Provider/PagerService/ MessageLength /Provider/Line /Provider/Line2 /Provider/City /Provider/State /Provider/Country /Provider/ZipCode /Provider/PhoneNumber /Provider/FaxNumber /Provider/Specialty Reference Only String 255 String String 00 String 20 String 3 String 2 String 20 String String 20 String 000 String 25 String 20 String 6 String 0 String 0 String 20 String 20
232 230 Connectivity Guide Paceart ML Schema Patient Medication The root path in the ML output for the following table is /PaceartML/PatientRecord/Medications/ PatientMedication. Patient Medication Date Dispensed Patient Medication Discontinued Date Patient Medication Tablets Dispensed Patient Medication Refills Patient Medication Dispense As Written Patient Medication Directions For Use Patient Medication Discontinued Patient Medication Discontinued Reason Patient Medication Comments Path /DateDispensed /DiscontinuedDate /TabletsDispensed /Refills /DispenseAsWritten /DirectionsForUse /IsDiscontinued /DiscontinuedReason /Comment String 255 String 255 String 255 The root path in the ML output for the following table is /PaceartML/PatientRecord/Medications/ PatientMedication/Medication. Medication Description Medication Comments Medication Side Effect Medication Side Effect 2 Medication Side Effect 3 Medication Side Effect 4 Medication Side Effect 5 Medication Side Effect 6 Path /Description /Comments /SideEffect /SideEffect2 /SideEffect3 /SideEffect4 /SideEffect5 /SideEffect6 String 40 String 00 The root path in the ML output for the following table is /PaceartML/PatientRecord/Medications/ PatientMedication/Provider. Provider Last Name Provider First Name Provider Middle Initial Provider Address Provider Credentials Provider Bill Code Path /LastName /FirstName /MiddleInitial / /Credentials /BillCode String String 00 String 20 String 3
233 Connectivity Guide Paceart ML Schema 23 Provider ID Provider NPI Provider SSN Provider UPIN Provider Comments Provider Pager PIN Provider CardioVoice ID Provider Code Pager Service Name Pager Service Name Pager Service Phone Pager Service Message Length Provider Address Line Provider Address Line 2 Provider Address City Provider Address State Provider Address Country Provider Address Postal Code Provider Phone Number Provider Fax Number Provider Specialty Path /ProviderID /NPI /SSN /UPIN /Comments /PagerPin /CardioVoiceID /ProviderCode /PagerService/Name /PagerService/Description /PagerService/PhoneNumber /PagerService/MessageLength /Line /Line2 /City /State /Country /ZipCode /PhoneNumber /FaxNumber /Specialty String 2 String 20 String String 20 String 000 String 25 String 20 String 6 String 0 String 0 String 20 String 20 Patient Insurance The root path in the ML output for the following table is /PaceartML/PatientRecord/Insurances/ PatientInsurance. Patient Insurance Policy Holder Name Patient Insurance Policy Holder Employer Patient Insurance Policy Holder Social Security Number Patient Insurance Policy Holder Certificate Number Patient Insurance Policy Holder Policy Number Patient Insurance Patient Insurance Status Path /InsuredName /InsuredEmployer /InsuredSocialSecurityNumber /InsuredCertificateNumber /InsuredPolicyNumber /PatientInsurance /IsActive String String 20 String 20
234 232 Connectivity Guide Paceart ML Schema Patient Insurance Comments Patient Insurance Effective Date Path /Comment /EffectiveDate String 255 The root path in the ML output for the following table is /PaceartML/PatientRecord/Insurances/ PatientInsurance/Insurance. Insurance Company Code Insurance Company Name Insurance Company Address Line Insurance Company Address Line 2 Insurance Company Adress City Insurance Company Adress State Insurance Company Address Postal Code Insurance Company Adress Country Insurance Company Phone Number Insurance Company Fax Number Insurance Company Comment Path /Code /Name /Line /Line2 /City /State /ZipCode /Country /PhoneNumber /FaxNumber /Comment String 8 String 0 String 0 String 20 String 20 String 00 Patient Devices The root path in the ML output for the following table is /PaceartML/PatientRecord/ActiveDevices/ PatientActiveDevice. NA Patient Device Serial Number Patient Device Comments Path /Key /SerialNumber /Comments String 20 String 000 The root path in the ML output for the following table is /PaceartML/PatientRecord/ActiveDevices/ PatientActiveDevice/Device. Device Manufacturer Device Model Device Universal Product Code Device Device MRI Compatibility Path /Manufacturer /Model /UniversalProductCode / /MriCompatibility String 20
235 Connectivity Guide Paceart ML Schema 233 Device Remote Follow Up Service Supported Device Beginning Of Service Indicator Device Elective Replacement Time Indicator Device Elective Replacement Time Indicator Charge Time Device Elective Replacement Time Indicator Battery Voltage Device Recommended Replacement Time Indicator Charge Time Device Recommended Replacement Time Indicator Battery Voltage Device End Of Service Indicator Device End Of Service Indicator Charge Time Device End Of Service Indicator Battery Voltage Device Comments Path /RemoteFollowupServiceSupported [='IPG' or 'CRT_P']/BOS /ERT /ERTCharge /ERTVoltage /RRTChargeTime /RRTVoltage [='IPG' or 'CRT_P']/EOS [='ICD' or 'CRT_D']/ EOSChargeTime [='ICD' or 'CRT_D']/ EOSVoltage /Comments String 000 The root path in the ML output for the following table is /PaceartML/PatientRecord/ActiveDevices/ PatientActiveDevice/PatientDeviceAlerts/PatientDeviceAlert. Patient Device Alert Status=[ONWATCH] Patient Device Alert Status=[ONALERT] Alert Details Alert Details Website URL Alert Resolution Details Alert Created Date Alert Created By Alert Resolution Date Alert Resolution By Alert Mitigation Complete Alert Mitigation Date Alert Mitigation By Path /IsWatch /IsModelAlert /Details /Website /ResolutionDetails /CreatedDate /CreatedUserName /ResolutionDate /ResolutionUserName /MitigationComplete /MitigationDate /MitigationUserName String 024 String 256 String 024
236 234 Connectivity Guide Paceart ML Schema Alert Mitigation Details Path /MitigationDetails String 024 The root path in the ML output for the following table is /PaceartML/PatientRecord/ActiveDevices/ PatientActiveDevice. Patient Device Implant Date Patient Device Implant Facility Patient Device Implant Patient Device Complication Path /ImplantDate /ImplantFacility /Implant /ImplantComplication String 00 The root path in the ML output for the following table is /PaceartML/PatientRecord/ActiveDevices/ PatientActiveDevice/ImplantDiagnosis. Diagnosis Code Diagnosis Description Diagnosis Comments Path /Code /Description /Comments String 6 String 00 The root path in the ML output for the following table is /PaceartML/PatientRecord/ActiveDevices/ PatientActiveDevice/FirstImplantingProvider. Provider Last Name Provider First Name Provider Middle Initial Provider Address Provider Credentials Provider Bill Code Provider ID Provider NPI Provider SSN Provider UPIN Provider Comments Provider Pager PIN Provider CardioVoice ID Provider Code Pager Service Name Pager Service Name Pager Service Phone Path /LastName /FirstName /MiddleName / /Credentials /BillCode /ProviderID /NPI /SSN /UPIN /Comments /PagerPin /CardiovoiceID /ProviderCode /PagerService/Name /PagerService/Description /PagerService/PhoneNumber String String 00 String 20 String 3 String 2 String 20 String String 20 String 000 String 25 String 20 String 6
237 Connectivity Guide Paceart ML Schema 235 Pager Service Message Length Provider Address Line Provider Address Line 2 Provider Address City Provider Address State Provider Address Country Provider Address Postal Code Provider Phone Number Provider Fax Number Provider Specialty Path /PagerService/MessageLength /Line /Line2 /City /State /Country /ZipCode /PhoneNumber /FaxNumber /Specialty String 0 String 0 String 20 String 20 The root path in the ML output for the following table is /PaceartML/PatientRecord/ActiveDevices/ PatientActiveDevice/SecondImplantingProvider. Provider Last Name Provider First Name Provider Middle Initial Provider Address Provider Credentials Provider Bill Code Provider ID Provider NPI Provider SSN Provider UPIN Provider Comments Provider Pager PIN Provider CardioVoice ID Provider Code Pager Service Name Pager Service Name Pager Service Phone Pager Service Message Length Provider Address Line Provider Address Line 2 Provider Address City Provider Address State Path /LastName /FirstName /MiddleName / /Credentials /BillCode /ProviderID /NPI /SSN /UPIN /Comments /PagerPin /CardiovoiceID /ProviderCode /PagerService/Name /PagerService/Description /PagerService/PhoneNumber /PagerService/MessageLength /Line /Line2 /City /State String String 00 String 20 String 3 String 2 String 20 String String 20 String 000 String 25 String 20 String 6 String 0
238 236 Connectivity Guide Paceart ML Schema Provider Address Country Provider Address Postal Code Provider Phone Number Provider Fax Number Provider Specialty Path /Country /ZipCode /PhoneNumber /FaxNumber /Specialty String 0 String 20 String 20 The root path in the ML output for the following table is /PaceartML/PatientRecord/ActiveDevices/ PatientActiveDevice. Patient Device Abandoned Date Path /AbandonedDate The root path in the ML output for the following table is /PaceartML/PatientRecord/ActiveDevices/ PatientActiveDevice/AbandonedProvider. Provider Last Name Provider First Name Provider Middle Initial Provider Address Provider Credentials Provider Bill Code Provider ID Provider NPI Provider SSN Provider UPIN Provider Comments Provider Pager PIN Provider CardioVoice ID Provider Code Pager Service Name Pager Service Name Pager Service Phone Pager Service Message Length Provider Address Line Provider Address Line 2 Provider Address City Provider Address State Provider Address Country Path /LastName /FirstName /MiddleName / /Credentials /BillCode /ProviderID /NPI /SSN /UPIN /Comments /PagerPin /CardiovoiceID /ProviderCode /PagerService/Name /PagerService/Description /PagerService/PhoneNumber /PagerService/MessageLength /Line /Line2 /City /State /Country String String 00 String 20 String 3 String 2 String 20 String String 20 String 000 String 25 String 20 String 6 String 0
239 Connectivity Guide Paceart ML Schema 237 Provider Address Postal Code Provider Phone Number Provider Fax Number Provider Specialty Path /ZipCode /PhoneNumber /FaxNumber /Specialty String 0 String 20 String 20 The root path in the ML output for the following table is /PaceartML/PatientRecord/ActiveDevices/ PatientActiveDevice. Patient Device Partially Explanted Date Path /PartiallyExplantedDate The root path in the ML output for the following table is /PaceartML/PatientRecord/ActiveDevices/ PatientActiveDevice/PartiallyExplantedProvider. Provider Last Name Provider First Name Provider Middle Initial Provider Address Provider Credentials Provider Bill Code Provider ID Provider NPI Provider SSN Provider UPIN Provider Comments Provider Pager PIN Provider CardioVoice ID Provider Code Pager Service Name Pager Service Name Pager Service Phone Pager Service Message Length Provider Address Line Provider Address Line 2 Provider Address City Provider State Provider Address Country Path /LastName /FirstName /MiddleName / /Credentials /BillCode /ProviderID /NPI /SSN /UPIN /Comments /PagerPin /CardiovoiceID /ProviderCode /PagerService/Name /PagerService/Description /PagerService/PhoneNumber /PagerService/MessageLength /Line /Line2 /City /State /Country String String 00 String 20 String 3 String 2 String 20 String String 20 String 000 String 25 String 20 String 6 String 0
240 238 Connectivity Guide Paceart ML Schema Provider Address Postal Code Provider Phone Number Provider Fax Number Provider Specialty Path /ZipCode /PhoneNumber /FaxNumber /Specialty String 0 String 20 String 20 The root path in the ML output for the following table is /PaceartML/PatientRecord/ActiveDevices/ PatientActiveDevice. Patient Device Explanted Date Path /ExplantedDate The root path in the ML output for the following table is /PaceartML/PatientRecord/ActiveDevices/ PatientActiveDevice/ExplantedProvider. Provider Last Name Provider First Name Provider Middle Initial Provider Address Provider Credentials Provider Bill Code Provider ID Provider NPI Provider SSN Provider UPIN Provider Comments Provider Pager PIN Provider CardioVoice ID Provider Code Pager Service Name Pager Service Name Pager Service Phone Pager Service Message Length Provider Address Line Provider Address Line 2 Provider Address City Provider State Provider Address Country Provider Address Postal Code Path /LastName /FirstName /MiddleName / /Credentials /BillCode /ProviderID /NPI /SSN /UPIN /Comments /PagerPin /CardiovoiceID /ProviderCode /PagerService/Name /PagerService/Description /PagerService/PhoneNumber /PagerService/MessageLength /Line /Line2 /City /State /Country /ZipCode String String 00 String 20 String 3 String 2 String 20 String String 20 String 000 String 25 String 20 String 6 String 0 String 0
241 Connectivity Guide Paceart ML Schema 239 Provider Phone Number Provider Fax Number Provider Specialty Path /PhoneNumber /FaxNumber /Specialty String 20 String 20 The root path in the ML output for the following table is /PaceartML/PatientRecord/PassiveDevices/ PatientPassiveDevice. NA Patient Device Associated Device Patient Device Serial Number Patient Device Lead Access Patient Device Chamber Patient Device Pacing Device Manufacturer Device Model Device Universal Product Code Device Device Polarity Device MRI Compatibility Device Comments Patient Device Implant Date Patient Device Implant Facility Patient Device Implant Patient Device Complication Diagnosis Code Diagnosis Description Diagnosis Comment Path /Key /AssociatedDeviceKey /SerialNumber /LeadAccess /Chamber /Pacing /Device/Manufacturer /Device/Model /Device/UniversalProductCode /Device/ /Device/Polarity /Device/MriCompatibility /Device/Comments /ImplantDate /ImplantFacility /Implant /ImplantComplication /ImplantDiagnosis/Code /ImplantDiagnosis/Description /ImplantDiagnosis/Comment Reference Only String 20 String 20 String 000 String 00 String 6 String 00 The root path in the ML output for the following table is /PaceartML/PatientRecord/PassiveDevices/ PatientPassiveDevice/PatientDeviceAlerts/PatientDeviceAlert. Patient Device Alert Status=[ONWATCH] Patient Device Alert Status=[ONALERT] Alert Details Alert Details Website URL Path /IsWatch /IsModelAlert /Details /Website String 024 String 256
242 240 Connectivity Guide Paceart ML Schema Alert Resolution Details Alert Created Date Alert Created By Alert Resolution Date Alert Resolution By Alert Mitigation Complete Alert Mitigation Date Alert Mitigation By Alert Mitigation Details Path /ResolutionDetails /CreatedDate /CreatedUserName /ResolutionDate /ResolutionUserName /MitigationComplete /MitigationDate /MitigationUserName /MitigationDetails String 024 String 024 The root path in the ML output for the following table is /PaceartML/PatientRecord/PassiveDevices/ PatientPassiveDevice/FirstImplantingProvider. Provider Last Name Provider First Name Provider Middle Initial Provider Address Provider Credentials Provider Bill Code Provider ID Provider NPI Provider SSN Provider UPIN Provider Comments Provider Pager PIN Provider CardioVoice ID Provider Code Pager Service Name Pager Service Name Pager Service Phone Pager Service Message Length Provider Address Line Provider Address Line 2 Provider Address City Provider State Provider Address Country Path /LastName /FirstName /MiddleName / /Credentials /BillCode /ProviderID /NPI /SSN /UPIN /Comments /PagerPin /CardiovoiceID /ProviderCode /PagerService/Name /PagerService/Description /PagerService/PhoneNumber /PagerService/MessageLength /Line /Line2 /City /State /Country String String 00 String 20 String 3 String 2 String 20 String String 20 String 000 String 25 String 20 String 6 String 0
243 Connectivity Guide Paceart ML Schema 24 Provider Address Postal Code Provider Phone Number Provider Fax Number Provider Specialty Path /ZipCode /PhoneNumber /FaxNumber /Specialty String 0 String 20 String 20 The root path in the ML output for the following table is /PaceartML/PatientRecord/PassiveDevices/ PatientPassiveDevice/SecondImplantingProvider. Provider Last Name Provider First Name Provider Middle Initial Provider Address Provider Credentials Provider Bill Code Provider ID Provider NPI Provider SSN Provider UPIN Provider Comments Provider Pager PIN Provider CardioVoice ID Provider Code Pager Service Name Pager Service Name Pager Service Phone Pager Service Message Length Provider Address Line Provider Address Line 2 Provider Address City Provider State Provider Address Country Provider Address Postal Code Provider Phone Number Provider Fax Number Provider Specialty Path /LastName /FirstName /MiddleName / /Credentials /BillCode /ProviderID /NPI /SSN /UPIN /Comments /PagerPin /CardiovoiceID /ProviderCode /PagerService/Name /PagerService/Description /PagerService/PhoneNumber /PagerService/MessageLength /Line /Line2 /City /State /Country /ZipCode /PhoneNumber /FaxNumber /Specialty String String 00 String 20 String 3 String 2 String 20 String String 20 String 000 String 25 String 20 String 6 String 0 String 0 String 20 String 20
244 242 Connectivity Guide Paceart ML Schema The root path in the ML output for the following table is /PaceartML/PatientRecord/PassiveDevices/ PatientPassiveDevice. Patient Device Abandoned Date Path /AbandonedDate The root path in the ML output for the following table is /PaceartML/PatientRecord/PassiveDevices/ PatientPassiveDevice/AbandonedProvider. Provider Last Name Provider First Name Provider Middle Initial Provider Address Provider Credentials Provider Bill Code Provider ID Provider NPI Provider SSN Provider UPIN Provider Comments Provider Pager PIN Provider CardioVoice ID Provider Code Pager Service Name Pager Service Name Pager Service Phone Pager Service Message Length Provider Address Line Provider Address Line 2 Provider Address City Provider State Provider Address Country Provider Address Postal Code Provider Phone Number Provider Fax Number Provider Specialty Path /LastName /FirstName /MiddleName / /Credentials /BillCode /ProviderID /NPI /SSN /UPIN /Comments /PagerPin /CardiovoiceID /ProviderCode /PagerService/Name /PagerService/Description /PagerService/PhoneNumber /PagerService/MessageLength /Line /Line2 /City /State /Country /ZipCode /PhoneNumber /FaxNumber /Specialty String String 00 String 20 String 3 String 2 String 20 String String 20 String 000 String 25 String 20 String 6 String 0 String 0 String 20 String 20 The root path in the ML output for the following table is /PaceartML/PatientRecord/PassiveDevices/ PatientPassiveDevice.
245 Connectivity Guide Paceart ML Schema 243 Patient Device Partially Explanted Date Path /PartiallyExplantedDate The root path in the ML output for the following table is /PaceartML/PatientRecord/PassiveDevices/ PatientPassiveDevice/PartiallyExplantedProvider. Provider Last Name Provider First Name Provider Middle Initial Provider Address Provider Credentials Provider Bill Code Provider ID Provider NPI Provider SSN Provider UPIN Provider Comments Provider Pager PIN Provider CardioVoice ID Provider Code Pager Service Name Pager Service Name Pager Service Phone Pager Service Message Length Provider Address Line Provider Address Line 2 Provider Address City Provider State Provider Address Country Provider Address Postal Code Provider Phone Number Provider Fax Number Provider Specialty Path /LastName /FirstName /MiddleName / /Credentials /BillCode /ProviderID /NPI /SSN /UPIN /Comments /PagerPin /CardiovoiceID /ProviderCode /PagerService/Name /PagerService/Description /PagerService/PhoneNumber /PagerService/MessageLength /Line /Line2 /City /State /Country /ZipCode /PhoneNumber /FaxNumber /Specialty String String 00 String 20 String 3 String 2 String 20 String String 20 String 000 String 25 String 20 String 6 String 0 String 0 String 20 String 20 The root path in the ML output for the following table is /PaceartML/PatientRecord/PassiveDevices/ PatientPassiveDevice.
246 244 Connectivity Guide Paceart ML Schema Patient Device Explanted Date Path /ExplantedDate The root path in the ML output for the following table is /PaceartML/PatientRecord/PassiveDevices/ PatientPassiveDevice/ExplantedProvider. Provider Last Name Provider First Name Provider Middle Initial Provider Address Provider Credentials Provider Bill Code Provider ID Provider NPI Provider SSN Provider UPIN Provider Comments Provider Pager PIN Provider CardioVoice ID Provider Code Pager Service Name Pager Service Name Pager Service Phone Pager Service Message Length Provider Address Line Provider Address Line 2 Provider Address City Provider State Provider Address Country Provider Address Postal Code Provider Phone Number Provider Fax Number Provider Specialty Path /LastName /FirstName /MiddleName / /Credentials /BillCode /ProviderID /NPI /SSN /UPIN /Comments /PagerPin /CardiovoiceID /ProviderCode /PagerService/Name /PagerService/Description /PagerService/PhoneNumber /PagerService/MessageLength /Line /Line2 /City /State /Country /ZipCode /PhoneNumber /FaxNumber /Specialty String String 00 String 20 String 3 String 2 String 20 String String 20 String 000 String 25 String 20 String 6 String 0 String 0 String 20 String 20 The root path in the ML output for the following table is /PaceartML/PatientRecord/Instruments/ PatientInstrument. NA Path /Key
247 Connectivity Guide Paceart ML Schema 245 Patient Device Serial Number Device Manufacturer Device Model Device Universal Product Code Device Device Default Transtelephonic Waveform Display Invert Polarity Device Default Transtelephonic Waveform Display Gain Device Default Transtelephonic Signal Transmission Speed Multiplier Device Transtelephonic Signal Transmission Format Device Comments Patient Device Given Date Patient Device Event Recorder Return Due Number of Days Patient Device Event Recorder Return Due Date Patient Device Returned Date Patient Device Comments Path /SerialNumber /Device/Manufacturer /Device/Model /Device/UniversalProductCode /Device/ /Device/ TTMWaveformInvertPolarity /Device/WaveformDisplayGain /Device/TransmitMultiplier /Device/TransmissionFormat /Device/Comments /GivenDate /EventRecorderReturnDueDays /EventRecorderReturnDueDate /ReturnedDate /Comments String 20 String 20 String 000 String 000 The root path in the ML output for the following table is /PaceartML/PatientRecord/Instruments/ PatientInstrument/PatientDeviceAlerts/PatientDeviceAlert. Patient Device Alert Status=[ONWATCH] Patient Device Alert Status=[ONALERT] Alert Details Alert Details Website URL Alert Resolution Details Alert Created Date Alert Created By Alert Resolution Date Alert Resolution By Alert Mitigation Complete Alert Mitigation Date Path /IsWatch /IsModelAlert /Details /Website /ResolutionDetails /CreatedDate /CreatedUserName /ResolutionDate /ResolutionUserName /MitigationComplete /MitigationDate String 024 String 256 String 024
248 246 Connectivity Guide Paceart ML Schema Alert Mitigation By Alert Mitigation Details Path /MitigationUserName /MitigationDetails String 024 Patient Miscellaneous The root path in the ML output for the following table is /PaceartML/PatientRecord/Allergies. Patient Allergies Path /Allergies String 255 Patient The root path in the ML output for the following table is /PaceartML/PatientRecord/s/. NA NA External Date Visit ID Device Instrument RemoteSystemID RemoteSystemName In-Patient Status Information Comment Source Status Path /Key /ParentKey / /Date /VisitId /DeviceKey /InstrumentKey /RemoteSystemId /RemoteSystemName /InPatientStatus /Comment /IsCardioVoice /IsLocked Reference Only Reference Only String 75 String 00 String 255 The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /Observations. Observation Blood Pressure Observation Weight Observation Height Observation Body Mass Index Path /BloodPressure /Weight /Height /BMI String 25 String 20 String 20 String 20 The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /Observations/ECG.
249 Connectivity Guide Paceart ML Schema 247 Evaluation Measured Cardiac Rate Minimum Evaluation Measured Cardiac Rate Maximum Evaluation Measured PR Cardiac Interval Minimum Evaluation Measured PR Cardiac Interval Maximum Evaluation Measured QRS Cardiac Interval Minimum Evaluation Measured QRS Cardiac Interval Maximum Evaluation Measured QT Cardiac Interval Minimum Evaluation Measured QT Cardiac Interval Maximum Evaluation Measured Bradycardia Presenting Cardiac Interval Evaluation Measured Bradycardia Presenting AV Delay Interval Evaluation Measured Bradycardia Magnet Cardiac Interval Evaluation Measured Bradycardia Magnet AV Delay Interval Evaluation Measured Bradycardia Magnet Right Atrial Pacing Pulse Width Evaluation Measured Bradycardia Magnet Right Ventricular Pacing Pulse Width Path /MinRate /MaxRate /MinPR /MaxPR /MinQRS /MaxQRS /MinQT /MaxQT /Presenting /PresentingAVD /Magnet /MagnetAVD /ADuration /VDuration The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /Observations/Arrhythmia. Observation Arrhythmia Symptoms Observation Arrhythmia Observation Arrhythmia Activity Path /Symptoms / /Activity String 80 String 80 String 80
250 248 Connectivity Guide Paceart ML Schema Observation Arrhythmia Findings Path /Findings String 255 The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /Evaluation. Observation Bradycardia Pacing Dependent Observation Rhythm Bradycardia Notes Comment Episodes Comment Comment Path /Dependency /Rhythm /BradyComment /TachyComment /EpisodesComment /MiscellaneousComment String 2 String 75 String 255 String 255 String 255 String The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /Miscellaneous. Description Path /Description String 255 The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /Evaluation/Thresholds[Chamber='RIGHT_ATRIUM']. Evaluation Observed Bradycardia Right Atrium Sensing Assessment Evaluation Observed Bradycardia Right Atrium Capture Assessment Path /Sensing /Capture The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /Evaluation/Thresholds[Chamber='RIGHT_VENTRICLE']. Evaluation Observed Bradycardia Right Ventricle Sensing Assessment Evaluation Observed Bradycardia Right Ventricle Capture Assessment Path /Sensing /Capture The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /Evaluation/Thresholds[Chamber='LEFT_VENTRICLE'].
251 Connectivity Guide Paceart ML Schema 249 Evaluation Observed Bradycardia Left Ventricle Sensing Assessment Evaluation Observed Bradycardia Left Ventricle Capture Assessment Path /Sensing /Capture The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /Attachments/Attachment. Attachment Description Attachment File Name Link Destination Path /Description /FileName /Content/URL String 255 String The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /Phone. Phone Note Caller Phone Note Staff Phone Note Reason Path /Caller /Staff /Reason String 255 String 255 String 255 The root path in the ML output for the following table is /OfCare. /PaceartML/PatientRecord/s/ of Care Abbreviation of Care Address City of Care Comment of Care Contact of Care Contact Name of Care Fax Number of Care Name of Care Phone Number of Care Address Line of Care Address Line 2 of Care Address State of Care Address Postal Code of Care Address Country Path /Abbreviation /City /Comments /Contact /ContactName /FaxNumber /Name /PhoneNumber /Line /Line2 /State /ZipCode /Country String 20 String 255 String 00 String 00 String 20 String 20 String 0 String 0
252 250 Connectivity Guide Paceart ML Schema The root path in the ML output for the following table is /Billing. /PaceartML/PatientRecord/s/ Billing Payment Amount Billing Visit ID Billing Admission Date Path /Amount /VisitNumber /AdmissionDate String 2 The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /Billing/Provider. Provider Last Name Provider First Name Provider Middle Initial Provider Address Provider Credentials Provider Bill Code Provider ID Provider NPI Provider SSN Provider UPIN Provider Comments Provider Pager PIN Provider CardioVoice ID Provider Code Pager Service Name Pager Service Name Pager Service Phone Pager Service Message Length Provider Address Line Provider Address Line 2 Provider City Provider State Provider Address Country Provider Address Postal Code Provider Phone Number Provider Fax Number Provider Specialty Path /LastName /FirstName /MiddleName / /Credentials /BillCode /ProviderID /NPI /SSN /UPIN /Comments /PagerPin /CardiovoiceID /ProviderCode /PagerService/Name /PagerService/Description /PagerService/PhoneNumber /PagerService/MessageLength /Line /Line2 /City /State /Country /ZipCode /PhoneNumber /FaxNumber /Specialty String String 00 String 20 String 3 String 2 String 20 String String 20 String 000 String 25 String 20 String 6 String 0 String 0 String 20 String 20
253 Connectivity Guide Paceart ML Schema 25 The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /Billing/ChargeCode. Charge Code Internal Charge Code Description Charge Code External Path /InternalCode /Description /ExternalCode String 8 String 8 The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /Billing/PaymentMethod. Payment Method Code Payment Method Description Path /Code /Description String 8 The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /Billing/BillingDiagnoses/BillingDiagnosis[Position='']. Diagnosis Code Diagnosis Description Diagnosis Comments Path /Diagnosis/Code /Diagnosis/Description /Diagnosis/Comments String 6 String 00 The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /Billing/BillingDiagnoses/BillingDiagnosis[Position='2']. Diagnosis Code Diagnosis Description Diagnosis Comments Path /Diagnosis/Code /Diagnosis/Description /Diagnosis/Comments String 6 String 00 The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /Billing/BillingDiagnoses/BillingDiagnosis[Position='3']. Diagnosis Code Diagnosis Description Diagnosis Comments Path /Diagnosis/Code /Diagnosis/Description /Diagnosis/Comments String 6 String 00 The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /Billing/BillingDiagnoses/BillingDiagnosis[Position='4']. Diagnosis Code Diagnosis Description Diagnosis Comments Path /Diagnosis/Code /Diagnosis/Description /Diagnosis/Comments String 6 String 00
254 252 Connectivity Guide Paceart ML Schema The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /Billing/BillingCPTCodes/BillingCPTCode[Position='']. CPT Code CPT Code Description Path /CPTCode/Code /CPTCode/Description String 8 The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /Billing/BillingCPTCodes/BillingCPTCode[Position='2']. CPT Code CPT Code Description Path /CPTCode/Code /CPTCode/Description String 8 The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /Billing/BillingCPTCodes/BillingCPTCode[Position='3']. CPT Code CPT Code Description Path /CPTCode/Code /CPTCode/Description String 8 The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /Billing/BillingCPTCodes/BillingCPTCode[Position='4']. CPT Code CPT Code Description Path /CPTCode/Code /CPTCode/Description String 8 The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /Signature. NA Signature User Name Signature Date and Time Path /SignerID /SignerName /SignatureDate Reference Only String 254 Bradycardia The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Programming/Bradycardia. Bradycardia Pacing Mode Bradycardia Lower Rate Bradycardia Maximum Tracking Rate Path /PacingMode /LowerRate /TrackingRate
255 Connectivity Guide Paceart ML Schema 253 Bradycardia Maximum Sensor Rate Bradycardia Hysteresis Rate Bradycardia Sleep Rate Path /MaxSensorRate /HysteresisRate /SleepRate The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Programming/Bradycardia/Sensing/ SensingData[Chamber='RIGHT_ATRIUM']/RefractoryPeriodCollection/RefractoryPeriod. Bradycardia Right Atrium Sensing Post Ventricular Refractory Period Interval Path [PreviousEventChamber='RIGHT_VENTRICLE']/ Interval [PreviousEventChamber='LEFT_VENTRICLE']/ Interval [PreviousEventChamber='VENTRICLE']/ Interval The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Programming/Bradycardia/Sensing/ SensingData[Chamber='RIGHT_ATRIUM']/BlankingPeriodCollection/BlankingPeriod. Bradycardia Right Atrium Sensing Post Ventricular Blanking Interval Path [PreviousEventChamber='RIGHT_VENTRICLE'][PreviousEvent='PACE']/ Interval [PreviousEventChamber='RIGHT_VENTRICLE'][PreviousEvent='SENSE']/ Interval [PreviousEventChamber='RIGHT_VENTRICLE'][PreviousEvent='SENSE_OR_PACE']/ Interval [PreviousEventChamber='RIGHT_VENTRICLE']/ [PreviousEventChamber='LEFT_VENTRICLE'][PreviousEvent='PACE']/ Interval [PreviousEventChamber='LEFT_VENTRICLE'][PreviousEvent='SENSE']/ Interval [PreviousEventChamber='LEFT_VENTRICLE'][PreviousEvent='SENSE_OR_PACE']/ Interval [PreviousEventChamber='LEFT_VENTRICLE']/ [PreviousEventChamber='VENTRICLE'][PreviousEvent='PACE']/ Interval [PreviousEventChamber='VENTRICLE'][PreviousEvent='SENSE']/ Interval [PreviousEventChamber='VENTRICLE'][PreviousEvent='SENSE_OR_PACE']/ Interval [PreviousEventChamber='VENTRICLE']/
256 254 Connectivity Guide Paceart ML Schema The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Programming/HeartFailure. Heart Failure Ventricular Pacing Configuration Heart Failure Ventricular Pacing Sequence VV Delay Path /VentricularPacingConfiguration /VentricularFirstChamberPaced /VVDelay The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Programming/Bradycardia/RateModulation. Bradycardia Rate Modulation Threshold Bradycardia Rate Modulation Slope Bradycardia Rate Modulation Slope Exertion Bradycardia Rate Modulation Acceleration Reaction Bradycardia Rate Modulation Deceleration Recovery Bradycardia Rate Modulation Activities of Daily Living Rate Path /Threshold /Slope /Slope_Exertion /AccelerationReaction /DecelerationRecovery /ADLRate The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Programming/Bradycardia/Pacing/ PacingData[Chamber='RIGHT_ATRIUM']. Bradycardia Right Atrium Pacing Amplitude Bradycardia Right Atrium Pacing Pulse Width Bradycardia Right Atrium Pacing Polarity Path /Amplitude /PulseWidth /PolarityConfiguration/Polarity
257 Connectivity Guide Paceart ML Schema 255 Bradycardia Right Atrium Pacing Polarity Bradycardia Right Atrium Pacing Bradycardia Right Atrium Pacing Bradycardia Right Atrium Pacing Adaptation Mode Path /PolarityConfiguration/s//Pole/ /PolarityConfiguration/s//Pole/ /PolarityConfiguration/s//Pole/ /AdaptationMode The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Programming/Bradycardia/Pacing/ PacingData[Chamber='RIGHT_VENTRICLE']. Bradycardia Right Ventricle Pacing Amplitude Bradycardia Right Ventricle Pacing Pulse Width Bradycardia Right Ventricle Pacing Polarity Bradycardia Right Ventricle Pacing Polarity Bradycardia Right Ventricle Pacing Bradycardia Right Ventricle Pacing Bradycardia Right Path /Amplitude /PulseWidth /PolarityConfiguration/Polarity /PolarityConfiguration/s//Pole/ /PolarityConfiguration/s//Pole/ /PolarityConfiguration/s//Pole/ /AdaptationMode
258 256 Connectivity Guide Paceart ML Schema Ventricle Pacing Adaptation Mode Path The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Programming/Bradycardia/Pacing/ PacingData[Chamber='LEFT_VENTRICLE']. Bradycardia Left Ventricle Pacing Amplitude Bradycardia Left Ventricle Pacing Pulse Width Bradycardia Left Ventricle Pacing Polarity Bradycardia Left Ventricle Pacing Polarity Bradycardia Left Ventricle Pacing Bradycardia Left Ventricle Pacing Bradycardia Left Ventricle Pacing Adaptation Mode Path /Amplitude /PulseWidth /PolarityConfiguration/Polarity /PolarityConfiguration/s//Pole/ /PolarityConfiguration/s//Pole/ /PolarityConfiguration/s//Pole/ /AdaptationMode The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Programming/Bradycardia/Sensing/ SensingData[Chamber='RIGHT_ATRIUM']]. Bradycardia Right Atrium Sensing Amplitude Bradycardia Right Atrium Sensing Polarity Path /Amplitude /PolarityConfiguration/Polarity
259 Connectivity Guide Paceart ML Schema 257 Bradycardia Right Atrium Sensing Polarity Bradycardia Right Atrium Sensing Bradycardia Right Atrium Sensing Bradycardia Right Atrium Sensing Amplitude Adaptation Mode Path /PolarityConfiguration/s//Pole/ /PolarityConfiguration/s//Pole/ /PolarityConfiguration/s//Pole/ /AmplitudeAdaptationMode The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Programming/Bradycardia/Sensing/ SensingData[Chamber='RIGHT_ATRIUM']/RefractoryPeriodCollection/RefractoryPeriod. Bradycardia Right Atrium Sensing Refractory Period Interval Path [PreviousEventChamber='RIGHT_ATRIUM']/ Interval [PreviousEventChamber='ATRIUM']/ Interval Interval The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Programming/Bradycardia/Sensing/ SensingData[Chamber='RIGHT_ATRIUM']/BlankingPeriodCollection/BlankingPeriod. Bradycardia Right Atrium Sensing Blanking Interval Path [PreviousEventChamber='RIGHT_ATRIUM'] [PreviousEvent='PACE']/ Interval [PreviousEventChamber='RIGHT_ATRIUM'] [PreviousEvent='SENSE']/ Interval [PreviousEventChamber='RIGHT_ATRIUM'] [PreviousEvent='SENSE_OR_PACE']/Interval [PreviousEventChamber='RIGHT_ATRIUM']/ [PreviousEventChamber='ATRIUM'] [PreviousEvent='PACE']/Interval [PreviousEventChamber=' ATRIUM'] [PreviousEvent='SENSE']/Interval [PreviousEventChamber='ATRIUM'] [PreviousEvent='SENSE_OR_PACE']/Interval
260 258 Connectivity Guide Paceart ML Schema Path [PreviousEventChamber='ATRIUM']/ [PreviousEvent='PACE']/Interval [PreviousEvent='SENSE']/Interval [PreviousEvent='SENSE_OR_PACE']/Interval The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Programming/Bradycardia/Sensing/ SensingData[Chamber='RIGHT_VENTRICLE']]. Bradycardia Right Ventricle Sensing Amplitude Bradycardia Right Ventricle Sensing Polarity Bradycardia Right Ventricle Sensing Polarity Bradycardia Right Ventricle Sensing Bradycardia Right Ventricle Sensing Bradycardia Right Ventricle Sensing Amplitude Adaptation Mode Path /Amplitude /PolarityConfiguration/Polarity /PolarityConfiguration/s//Pole/ /PolarityConfiguration/s//Pole/ /PolarityConfiguration/s//Pole/ /AmplitudeAdaptationMode
261 Connectivity Guide Paceart ML Schema 259 The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Programming/Bradycardia/Sensing/ SensingData[Chamber='RIGHT_VENTRICLE']/RefractoryPeriodCollection/RefractoryPeriod. Bradycardia Right Ventricle Sensing Refractory Period Interval Path [PreviousEventChamber='RIGHT_VENTRICLE']/ Interval [PreviousEventChamber='LEFT_VENTRICLE']/ Interval [PreviousEventChamber='VENTRICLE']/ Interval [PreviousEventChamber='RIGHT_ATRIUM']/ Interval [PreviousEventChamber='ATRIUM']/ Interval Interval The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Programming/Bradycardia/Sensing/ SensingData[Chamber='RIGHT_VENTRICLE']/BlankingPeriodCollection/BlankingPeriod. Path Bradycardia Right Ventricle Sensing Blanking Interval [PreviousEventChamber='RIGHT_VENTRICLE'] [PreviousEvent='PACE']/ Interval [PreviousEventChamber='RIGHT_VENTRICLE'] [PreviousEvent='SENSE']/Interval [PreviousEventChamber='RIGHT_VENTRICLE'] [PreviousEvent='SENSE_OR_PACE']/Interval [PreviousEventChamber='RIGHT_VENTRICLE']/ [PreviousEventChamber='LEFT_VENTRICLE'] [PreviousEvent='PACE']/ Interval [PreviousEventChamber='LEFT_VENTRICLE'] [PreviousEvent='SENSE']/ Interval [PreviousEventChamber='LEFT_VENTRICLE'] [PreviousEvent='SENSE_OR_PACE']/Interval [PreviousEventChamber='LEFT_VENTRICLE']/ [PreviousEventChamber='VENTRICLE'] [PreviousEvent='PACE']/Interval [PreviousEventChamber='VENTRICLE'] [PreviousEvent='SENSE']/ Interval [PreviousEventChamber='VENTRICLE'] [PreviousEvent='SENSE_OR_PACE']/Interval [PreviousEventChamber='VENTRICLE']/ [PreviousEventChamber='RIGHT_ATRIUM'] [PreviousEvent='PACE']/ Interval
262 260 Connectivity Guide Paceart ML Schema Path [PreviousEventChamber='RIGHT_ATRIUM'] [PreviousEvent='SENSE']/ Interval [PreviousEventChamber='RIGHT_ATRIUM'] [PreviousEvent='SENSE_OR_PACE']/Interval [PreviousEventChamber='RIGHT_ATRIUM']/ [PreviousEventChamber='ATRIUM'] [PreviousEvent='PACE']/Interval [PreviousEventChamber='ATRIUM'] [PreviousEvent='SENSE']/Interval [PreviousEventChamber='ATRIUM'] [PreviousEvent='SENSE_OR_PACE']/Interval [PreviousEventChamber='ATRIUM']/ [PreviousEvent='PACE']/ Interval [PreviousEvent='SENSE']/ Interval [PreviousEvent='SENSE_OR_PACE']/Interval The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Programming/Bradycardia/Sensing/ SensingData[Chamber='LEFT_VENTRICLE']]. Bradycardia Left Ventricle Sensing Amplitude Bradycardia Left Ventricle Sensing Polarity Bradycardia Left Ventricle Sensing Polarity Bradycardia Left Ventricle Sensing Path /Amplitude /PolarityConfiguration/Polarity /PolarityConfiguration/s//Pole/ /PolarityConfiguration/s//Pole/
263 Connectivity Guide Paceart ML Schema 26 Bradycardia Left Ventricle Sensing Bradycardia Left Ventricle Sensing Amplitude Adaptation Mode Path /PolarityConfiguration/s//Pole/ /AmplitudeAdaptationMode The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Programming/Bradycardia/Sensing/ SensingData[Chamber='LEFT_VENTRICLE']/RefractoryPeriodCollection/RefractoryPeriod. Path Bradycardia Left Ventricle Sensing Refractory Period Interval [PreviousEventChamber='RIGHT_VENTRICLE']/ Interval [PreviousEventChamber='LEFT_VENTRICLE']/ Interval [PreviousEventChamber='VENTRICLE']/ Interval [PreviousEventChamber='RIGHT_ATRIUM']/ Interval [PreviousEventChamber='ATRIUM']/ Interval Interval The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Programming/Bradycardia/Sensing/ SensingData[Chamber='LEFT_VENTRICLE']/BlankingPeriodCollection/BlankingPeriod. Bradycardia Left Ventricle Sensing Blanking Interval Path [PreviousEventChamber='RIGHT_VENTRICLE'] [PreviousEvent='PACE']/ Interval [PreviousEventChamber='RIGHT_VENTRICLE'] [PreviousEvent='SENSE']/Interval [PreviousEventChamber='RIGHT_VENTRICLE'] [PreviousEvent='SENSE_OR_PACE']/Interval [PreviousEventChamber='RIGHT_VENTRICLE']/ [PreviousEventChamber='LEFT_VENTRICLE'] [PreviousEvent='PACE']/ Interval [PreviousEventChamber='LEFT_VENTRICLE'] [PreviousEvent='SENSE']/ Interval [PreviousEventChamber='LEFT_VENTRICLE'] [PreviousEvent='SENSE_OR_PACE']/Interval
264 262 Connectivity Guide Paceart ML Schema Path [PreviousEventChamber='LEFT_VENTRICLE']/ [PreviousEventChamber='VENTRICLE'] [PreviousEvent='PACE']/Interval [PreviousEventChamber='VENTRICLE'] [PreviousEvent='SENSE']/Interval [PreviousEventChamber='VENTRICLE'] [PreviousEvent='SENSE_OR_PACE']/Interval [PreviousEventChamber='VENTRICLE']/ [PreviousEventChamber='RIGHT_ATRIUM'] [PreviousEvent='PACE']/ Interval [PreviousEventChamber='RIGHT_ATRIUM'] [PreviousEvent='SENSE']/ Interval [PreviousEventChamber='RIGHT_ATRIUM'] [PreviousEvent='SENSE_OR_PACE']/Interval [PreviousEventChamber='RIGHT_ATRIUM']/ [PreviousEventChamber='ATRIUM'] [PreviousEvent='PACE']/Interval [PreviousEventChamber='ATRIUM'] [PreviousEvent='SENSE']/Interval [PreviousEventChamber='ATRIUM'] [PreviousEvent='SENSE_OR_PACE']/ Interval Interval [PreviousEvent='PACE']/ Interval [PreviousEvent='SENSE']/ Interval [PreviousEvent='SENSE_OR_PACE']/Interval The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Programming/Bradycardia/AVDelay. Bradycardia AV Delay Adaptive Status Bradycardia AV Delay Paced Bradycardia AV Delay Sensed Path /Adaptive/Status /Paced /Sensed
265 Connectivity Guide Paceart ML Schema 263 Bradycardia AV Delay Adaptive Paced Minimum Bradycardia AV Delay Adaptive Sensed Minimum Bradycardia AV Delay Adaptive Start Rate Bradycardia AV Delay Adaptive Stop Rate Bradycardia AV Delay Adaptive Curve Description Path /Adaptive/PacedMinimum /Adaptive/SensedMinimum /Adaptive/StartRate /Adaptive/StopRate /Adaptive/CurveDescription The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Programming/Bradycardia/AutomaticModeSwitch. Bradycardia Automatic Mode Switch Detection Criteria Rate Bradycardia Automatic Mode Switch Status Bradycardia Automatic Mode Switch Detection Duration Fixed Bradycardia Automatic Mode Switch Detection Duration Beat Count Bradycardia Automatic Mode Switch Detection Duration Beat Ratio Numerator Bradycardia Automatic Mode Switch Detection Duration Beat Ratio Denominator Bradycardia Automatic Path /Detection/Criteria/Rate /Status /Detection/Criteria/Duration/Fixed /Detection/Criteria/Duration/BeatCount /Detection/Criteria/Duration/BeatRatio/Numerator /Detection/Criteria/Duration/BeatRatio/Denominator //Rate
266 264 Connectivity Guide Paceart ML Schema Mode Switch Pacing Rate Bradycardia Automatic Mode Switch Pacing Mode Path //PacingMode The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Programming/Bradycardia. Bradycardia Pacemaker Mediated Intervention Bradycardia Premature Ventricular Contraction Intervention Path /PMTIntervention /PVCResponse Statistics The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Battery. Measured Device Battery Timestamp Measured Device Battery Status Measured Device Battery Status RRT Trigger Measured Device Battery Remaining Longevity Measured Device Battery Remaining Percentage Measured Device Battery Voltage Measured Device Battery Impedance Path /Timestamp /Status /StatusRRTTrigger /RemainingLongevity /RemainingPercentage /Voltage /Impedance The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Capacitor/ LastCharge[='FULL_ENERGY']. Measured Device Capacitor Last Full Energy Charge Timestamp Path /Timestamp
267 Connectivity Guide Paceart ML Schema 265 Measured Device Capacitor Last Full Energy Charge Interval Measured Device Capacitor Last Full Energy Charge Measured Device Capacitor Last Full Energy Charge Voltage Path /Duration /Energy /Voltage The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Capacitor/ LastCharge[='REFORMATION']. Measured Device Capacitor Last Reformation Timestamp Measured Device Capacitor Last Reformation Interval Measured Device Capacitor Last Reformation Energy Measured Device Capacitor Last Reformation Voltage Path /Timestamp /Duration /Energy /Voltage The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Capacitor/LastCharge[='SHOCK']. Measured Device Capacitor Last Charge Timestamp Measured Device Capacitor Last Charge Interval Measured Device Capacitor Last Charge Energy Measured Device Capacitor Last Charge Voltage Path /Timestamp /Duration /Energy /Voltage The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Leads/Lead[Chamber='RIGHT_ATRIUM']/ LowPowerChannel. Measured Right Atrium Lead Low Power Channel Status Path /Status
268 266 Connectivity Guide Paceart ML Schema Measured Right Atrium Lead Low Power Channel Sensing Integrity Counter Start Date Measured Right Atrium Lead Low Power Channel Sensing Integrity Counter End Date Measured Right Atrium Lead Low Power Channel Sensing Integrity Counter Count Measured Right Atrium Lead Low Power Channel Evoked Response Measured Right Atrium Lead Low Power Channel Polarization Path /SensingIntegrityCounter/StartDate /SensingIntegrityCounter/EndDate /SensingIntegrityCounter/Count /EvokedResponse /Polarization The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Leads/Lead[Chamber='RIGHT_ATRIUM']/ LowPowerChannel/ImpedanceCollections/ImpedanceCollection. Measured Right Atrium Lead Low Power Channel Impedance Collection Id Measured Right Atrium Lead Low Power Channel Impedance Measurement Method Measured Right Atrium Lead Low Power Channel Impedance Method Variance Measured Right Atrium Lead Low Power Channel Impedance Polarity Measured Right Atrium Lead Low Path /Id /Method /Method_Variance /PolarityConfiguration/Polarity /PolarityConfiguration/s//Pole/
269 Connectivity Guide Paceart ML Schema 267 Power Channel Impedance Polarity Measured Right Atrium Lead Low Power Channel Impedance Measured Right Atrium Lead Low Power Channel Impedance Measured Right Atrium Lead Low Power Channel Impedance Impedance Id Measured Right Atrium Lead Low Power Channel Impedance Impedance Start Date Measured Right Atrium Lead Low Power Channel Impedance Impedance End Date Measured Right Atrium Lead Low Power Channel Impedance Impedance Measurement Measured Right Atrium Lead Low Power Channel Impedance Path /PolarityConfiguration/s//Pole/ /PolarityConfiguration/s//Pole/ /Impedances/Impedance/Id /Impedances/Impedance/StartDate /Impedances/Impedance/EndDate /Impedances/Impedance/MeasurementCollection/Measurement/ /Impedances/Impedance/MeasurementCollection/Measurement/Value
270 268 Connectivity Guide Paceart ML Schema Impedance Measurement Value Path The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Leads/Lead[Chamber='RIGHT_ATRIUM']/ HighPowerChannel. Measured Right Atrium Lead High Power Channel Status Path /Status The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Leads/Lead[Chamber='RIGHT_ATRIUM']/ HighPowerChannel/ImpedanceCollections/ImpedanceCollection. Measured Right Atrium Lead High Power Channel Impedance Collection Id Measured Right Atrium Lead High Power Channel Impedance Measurement Method Measured Right Atrium Lead High Power Channel Impedance Method Variance Measured Right Atrium Lead High Power Channel Impedance Polarity Measured Right Atrium Lead High Power Channel Impedance Measured Right Path /Id /Method /Method_Variance /s//pole/ /s//pole/ /s//pole/
271 Connectivity Guide Paceart ML Schema 269 Atrium Lead High Power Channel Impedance Measured Right Atrium Lead High Power Channel Impedance Id Measured Right Atrium Lead High Power Channel Impedance Start Date Measured Right Atrium Lead High Power Channel Impedance End Date Measured Right Atrium Lead High Power Channel Impedance Measurement Measured Right Atrium Lead High Power Channel Impedance Measurement Value Path /Impedances/Impedance/Id /Impedances/Impedance/StartDate /Impedances/Impedance/EndDate /Impedances/Impedance/MeasurementCollection/Measurement/ /Impedances/Impedance/MeasurementCollection/Measurement/Value The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Leads/Lead[Chamber='RIGHT_VENTRICLE']/ LowPowerChannel. Measured Right Ventricle Lead Low Power Channel Status Measured Right Ventricle Lead Low Power Channel Sensing Integrity Counter Start Date Path /Status /SensingIntegrityCounter/StartDate
272 270 Connectivity Guide Paceart ML Schema Measured Right Ventricle Lead Low Power Channel Sensing Integrity Counter End Date Measured Right Ventricle Lead Low Power Channel Sensing Integrity Counter Count Measured Right Ventricle Lead Low Power Channel Evoked Response Measured Right Ventricle Lead Low Power Channel Polarization Path /SensingIntegrityCounter/EndDate /SensingIntegrityCounter/Count /EvokedResponse /Polarization The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Leads/Lead[Chamber='RIGHT_VENTRICLE']/ LowPowerChannel/ImpedanceCollections/ImpedanceCollection. Measured Right Ventricle Lead Low Power Channel Impedance Collection Id Measured Right Ventricle Lead Low Power Channel Impedance Measurement Method Measured Right Ventricle Lead Low Power Channel Impedance Method Variance Measured Right Ventricle Lead Low Power Channel Impedance Polarity Measured Right Path /Id /Method /Method_Variance /PolarityConfiguration/Polarity /PolarityConfiguration/s//Pole/
273 Connectivity Guide Paceart ML Schema 27 Ventricle Lead Low Power Channel Impedance Polarity Measured Right Ventricle Lead Low Power Channel Impedance Measured Right Ventricle Lead Low Power Channel Impedance Measured Right Ventricle Lead Low Power Channel Impedance Id Measured Right Ventricle Lead Low Power Channel Impedance Start Date Measured Right Ventricle Lead Low Power Channel Impedance End Date Measured Right Ventricle Lead Low Power Channel Impedance Measurement Path /PolarityConfiguration/s//Pole/ /PolarityConfiguration/s//Pole/ /Impedances/Impedance/Id /Impedances/Impedance/StartDate /Impedances/Impedance/EndDate /Impedances/Impedance/MeasurementCollection/Measurement/
274 272 Connectivity Guide Paceart ML Schema Measured Right Ventricle Lead Low Power Channel Impedance Measurement Value Path /Impedances/Impedance/MeasurementCollection/Measurement/Value The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Leads/Lead[Chamber='RIGHT_VENTRICLE']/ HighPowerChannel. Measured Right Ventricle Lead High Power Channel Status Path /Status The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Leads/Lead[Chamber='RIGHT_VENTRICLE']/ HighPowerChannel/ImpedanceCollections/ImpedanceCollection. Measured Right Ventricle Lead High Power Channel Impedance Collection Id Measured Right Ventricle Lead High Power Channel Impedance Measurement Method Measured Right Ventricle Lead High Power Channel Impedance Method Variance Measured Right Ventricle Lead High Power Channel Impedance Polarity Path /Id /Method /Method_Variance /s//pole/
275 Connectivity Guide Paceart ML Schema 273 Measured Right Ventricle Lead High Power Channel Impedance Measured Right Ventricle Lead High Power Channel Impedance Measured Right Ventricle Lead High Power Channel Impedance Id Measured Right Ventricle Lead High Power Channel Impedance Start Date Measured Right Ventricle Lead High Power Channel Impedance End Date Measured Right Ventricle Lead High Power Channel Impedance Measurement Measured Right Ventricle Lead High Power Channel Impedance Path /s//pole/ /s//pole/ /Impedances/Impedance/Id /Impedances/Impedance/StartDate /Impedances/Impedance/EndDate /Impedances/Impedance/MeasurementCollection/Measurement/ /Impedances/Impedance/MeasurementCollection/Measurement/Value
276 274 Connectivity Guide Paceart ML Schema Measurement Value Path The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Leads/Lead[Chamber='LEFT_VENTRICLE']/ LowPowerChannel. Measured Left Ventricle Lead Low Power Channel Status Measured Left Ventricle Lead Low Power Channel Sensing Integrity Counter Start Date Measured Left Ventricle Lead Low Power Channel Sensing Integrity Counter End Date Measured Left Ventricle Lead Low Power Channel Sensing Integrity Counter Count Measured Left Ventricle Lead Low Power Channel Evoked Response Measured Left Ventricle Lead Low Power Channel Polarization Path /Status /SensingIntegrityCounter/StartDate /SensingIntegrityCounter/EndDate /SensingIntegrityCounter/Count /EvokedResponse /Polarization The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Leads/Lead[Chamber='LEFT_VENTRICLE']/ LowPowerChannel/ImpedanceCollections/ImpedanceCollection. Measured Left Ventricle Lead Low Power Channel Impedance Collection Id Measured Left Ventricle Lead Low Power Channel Impedance Measurement Method Measured Left Ventricle Lead Path /Id /Method /Method_Variance
277 Connectivity Guide Paceart ML Schema 275 Low Power Channel Impedance Method Variance Measured Left Ventricle Lead Low Power Channel Impedance Polarity Measured Left Ventricle Lead Low Power Channel Impedance Polarity Measured Left Ventricle Lead Low Power Channel Impedance Measured Left Ventricle Lead Low Power Channel Impedance Measured Left Ventricle Lead Low Power Channel Impedance Id Measured Left Ventricle Lead Low Power Channel Impedance Start Date Measured Left Ventricle Lead Low Power Path /PolarityConfiguration/Polarity /PolarityConfiguration/s//Pole/ /PolarityConfiguration/s//Pole/ /PolarityConfiguration/s//Pole/ /Impedances/Impedance/Id /Impedances/Impedance/StartDate /Impedances/Impedance/EndDate
278 276 Connectivity Guide Paceart ML Schema Channel Impedance End Date Measured Left Ventricle Lead Low Power Channel Impedance Measurement Measured Left Ventricle Lead Low Power Channel Impedance Measurement Value Path /Impedances/Impedance/MeasurementCollection/Measurement/ /Impedances/Impedance/MeasurementCollection/Measurement/Value The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Leads/Lead[Chamber='LEFT_VENTRICLE']/ HighPowerChannel. Measured Left Ventricle Lead High Power Channel Status Path /Status The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Leads/Lead[Chamber='LEFT_VENTRICLE']/ HighPowerChannel/ImpedanceCollections/ImpedanceCollection. Measured Left Ventricle Lead High Power Channel Impedance Collection Id Measured Left Ventricle Lead High Power Channel Impedance Measurement Method Measured Left Ventricle Lead Path /Id /Method /Method_Variance
279 Connectivity Guide Paceart ML Schema 277 High Power Channel Impedance Method Variance Measured Left Ventricle Lead High Power Channel Impedance Polarity Measured Left Ventricle Lead High Power Channel Impedance Measured Left Ventricle Lead High Power Channel Impedance Measured Left Ventricle Lead High Power Channel Impedance Id Measured Left Ventricle Lead High Power Channel Impedance Start Date Measured Left Ventricle Lead High Power Channel Impedance End Date Measured Left Ventricle Lead Path /s//pole/ /s//pole/ /s//pole/ /Impedances/Impedance/Id /Impedances/Impedance/StartDate /Impedances/Impedance/EndDate /Impedances/Impedance/MeasurementCollection/Measurement/
280 278 Connectivity Guide Paceart ML Schema High Power Channel Impedance Measurement Measured Left Ventricle Lead High Power Channel Impedance Measurement Value Path /Impedances/Impedance/MeasurementCollection/Measurement/Value The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Detections_Therapies/ PhysiologicalCollection/Physiological[Counter='SINCE_LA_SESSION']. Measured Physiological Measurements Since Last Session Start Date Measured Physiological Measurements Since Last Session End Date Path /StartDate /EndDate Measured Physiological Measurements Since Last Session Right Atrium Measured Heart Rate Measured Physiological Measurements Since Last Session Right Ventricle Measured Heart Rate Measured Physiological Measurements Since Last Session Left Ventricle Measured Heart Rate Measured Physiological Measurements Since Last Session Right Atrium Minimum Heart Rate Measured Physiological Measurements Since Last Session Right Ventricle Minimum Heart Rate Measured Physiological Measurements Since Last Session Left Ventricle Minimum Heart Rate Measured Physiological Measurements Since Last Session Right Atrium Mean Heart Rate Measured Physiological Measurements Since Last Session Right Ventricle Mean Heart Rate /HeartRates/ HeartRate[Chamber='RIGHT_ATRIUM'] [='MEASURED']/Rate /HeartRates/ HeartRate[Chamber='RIGHT_VENTRICLE'] [='MEASURED']/Rate /HeartRates/ HeartRate[Chamber='LEFT_VENTRICLE'] [='MEASURED']/Rate /HeartRates/ HeartRate[Chamber='RIGHT_ATRIUM'] [='MINIMUM']/Rate /HeartRates/ HeartRate[Chamber='RIGHT_VENTRICLE'] [=' MINIMUM']/Rate /HeartRates/ HeartRate[Chamber='LEFT_VENTRICLE'] [=' MINIMUM']/Rate /HeartRates/ HeartRate[Chamber='RIGHT_ATRIUM'] [='MEAN']/Rate /HeartRates/ HeartRate[Chamber='RIGHT_VENTRICLE'] [=' MEAN']/Rate
281 Connectivity Guide Paceart ML Schema 279 Measured Physiological Measurements Since Last Session Left Ventricle Mean Heart Rate Measured Physiological Measurements Since Last Session Right Atrium Maximum Heart Rate Measured Physiological Measurements Since Last Session Right Ventricle Maximum Heart Rate Measured Physiological Measurements Since Last Session Left Ventricle Maximum Heart Rate Path /HeartRates/ HeartRate[Chamber='LEFT_VENTRICLE'] [=' MEAN']/Rate /HeartRates/ HeartRate[Chamber='RIGHT_ATRIUM'] [='MAIMUM']/Rate /HeartRates/ HeartRate[Chamber='RIGHT_VENTRICLE'] [=' MAIMUM']/Rate /HeartRates/ HeartRate[Chamber='LEFT_VENTRICLE'] [=' MAIMUM']/Rate The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Detections_Therapies/ PhysiologicalCollection/Physiological[Counter='SINCE_LA_COUNTER_RESET']. Measured Physiological Measurements Since Last Counter Reset Start Date Measured Physiological Measurements Since Last Counter Reset End Date Path /StartDate /EndDate Measured Physiological Measurements Since Last Counter Reset Right Atrium Measured Heart Rate Measured Physiological Measurements Since Last Counter Reset Right Ventricle Measured Heart Rate Measured Physiological Measurements Since Last Counter Reset Left Ventricle Measured Heart Rate Measured Physiological Measurements Since Last Counter Reset Right Atrium Minimum Heart Rate Measured Physiological Measurements Since Last Counter Reset Right Ventricle Minimum Heart Rate Measured Physiological Measurements Since Last Counter Reset Left Ventricle Minimum Heart Rate Measured Physiological Measurements Since Last Counter Reset Right Atrium Mean Heart Rate /HeartRates/ HeartRate[Chamber='RIGHT_ATRIUM'] [='MEASURED']/Rate /HeartRates/ HeartRate[Chamber='RIGHT_VENTRICLE'] [='MEASURED']/Rate /HeartRates/ HeartRate[Chamber='LEFT_VENTRICLE'] [='MEASURED']/Rate /HeartRates/ HeartRate[Chamber='RIGHT_ATRIUM'] [='MINIMUM']/Rate /HeartRates/ HeartRate[Chamber='RIGHT_VENTRICLE'] [=' MINIMUM']/Rate /HeartRates/ HeartRate[Chamber='LEFT_VENTRICLE'] [=' MINIMUM']/Rate /HeartRates/ HeartRate[Chamber='RIGHT_ATRIUM'] [='MEAN']/Rate
282 280 Connectivity Guide Paceart ML Schema Measured Physiological Measurements Since Last Counter Reset Right Ventricle Mean Heart Rate Measured Physiological Measurements Since Last Counter Reset Left Ventricle Mean Heart Rate Measured Physiological Measurements Since Last Counter Reset Right Atrium Maximum Heart Rate Measured Physiological Measurements Since Last Counter Reset Right Ventricle Maximum Heart Rate Measured Physiological Measurements Since Last Counter Reset Left Ventricle Maximum Heart Rate Path /HeartRates/ HeartRate[Chamber='RIGHT_VENTRICLE'] [=' MEAN']/Rate /HeartRates/ HeartRate[Chamber='LEFT_VENTRICLE'] [=' MEAN']/Rate /HeartRates/ HeartRate[Chamber='RIGHT_ATRIUM'] [='MAIMUM']/Rate /HeartRates/ HeartRate[Chamber='RIGHT_VENTRICLE'] [=' MAIMUM']/Rate /HeartRates/ HeartRate[Chamber='LEFT_VENTRICLE'] [=' MAIMUM']/Rate The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Detections_Therapies/ PhysiologicalCollection/Physiological[Counter='LIFETIME']. Measured Physiological Measurements Lifetime Start Date Measured Physiological Measurements Lifetime End Date Path /StartDate /EndDate Measured Physiological Measurements Lifetime Right Atrium Measured Heart Rate Measured Physiological Measurements Lifetime Right Ventricle Measured Heart Rate Measured Physiological Measurements Lifetime Left Ventricle Measured Heart Rate Measured Physiological Measurements Lifetime Right Atrium Minimum Heart Rate Measured Physiological Measurements Lifetime Right Ventricle Minimum Heart Rate Measured Physiological Measurements Lifetime Left Ventricle Minimum Heart Rate Measured Physiological Measurements Lifetime Right Atrium Mean Heart Rate /HeartRates/ HeartRate[Chamber='RIGHT_ATRIUM'] [='MEASURED']/Rate /HeartRates/ HeartRate[Chamber='RIGHT_VENTRICLE'] [='MEASURED']/Rate /HeartRates/ HeartRate[Chamber='LEFT_VENTRICLE'] [='MEASURED']/Rate /HeartRates/ HeartRate[Chamber='RIGHT_ATRIUM'] [='MINIMUM']/Rate /HeartRates/ HeartRate[Chamber='RIGHT_VENTRICLE'] [=' MINIMUM']/Rate /HeartRates/ HeartRate[Chamber='LEFT_VENTRICLE'] [=' MINIMUM']/Rate /HeartRates/ HeartRate[Chamber='RIGHT_ATRIUM'] [='MEAN']/Rate
283 Connectivity Guide Paceart ML Schema 28 Measured Physiological Measurements Lifetime Right Ventricle Mean Heart Rate Measured Physiological Measurements Lifetime Left Ventricle Mean Heart Rate Measured Physiological Measurements Lifetime Right Atrium Maximum Heart Rate Measured Physiological Measurements Lifetime Right Ventricle Maximum Heart Rate Measured Physiological Measurements Lifetime Left Ventricle Maximum Heart Rate Path /HeartRates/ HeartRate[Chamber='RIGHT_VENTRICLE'] [=' MEAN']/Rate /HeartRates/ HeartRate[Chamber='LEFT_VENTRICLE'] [=' MEAN']/Rate /HeartRates/ HeartRate[Chamber='RIGHT_ATRIUM'] [='MAIMUM']/Rate /HeartRates/ HeartRate[Chamber='RIGHT_VENTRICLE'] [=' MAIMUM']/Rate /HeartRates/ HeartRate[Chamber='LEFT_VENTRICLE'] [=' MAIMUM']/Rate The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Detections_Therapies/ BradycardiaCollection/Bradycardia[Counter='SINCE_LA_SESSION']. Measured Bradycardia Measurements Since Last Session Start Date Measured Bradycardia Measurements Since Last Session End Date Measured Bradycardia Measurements Since Last Session AP VP Percent Measured Bradycardia Measurements Since Last Session AS VP Percent Path /StartDate /EndDate /APVPPercent /ASVPPercent
284 282 Connectivity Guide Paceart ML Schema Measured Bradycardia Measurements Since Last Session AP VS Percent Measured Bradycardia Measurements Since Last Session AS VS Percent Measured Bradycardia Measurements Since Last Session Right Atrium Percent Paced Measured Bradycardia Measurements Since Last Session Right Ventricle Percent Paced Measured Bradycardia Measurements Since Last Session Left Ventricle Percent Paced Path /APVSPercent /ASVSPercent /PercentPacedCollection/PercentPaced[Chamber='RIGHT_ATRIUM']/Percent /PercentPacedCollection/PercentPaced[Chamber='RIGHT_VENTRICLE']/ Percent /PercentPacedCollection/PercentPaced[Chamber='LEFT_VENTRICLE']/ Percent The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Detections_Therapies/ BradycardiaCollection/Bradycardia[Counter='SINCE_LA_COUNTER_RESET']. Measured Bradycardia Measurements Since Last Counter Reset Start Date Path /StartDate
285 Connectivity Guide Paceart ML Schema 283 Measured Bradycardia Measurements Since Last Counter Reset End Date Measured Bradycardia Measurements Since Last Counter Reset AP VP Percent Measured Bradycardia Measurements Since Last Counter Reset AS VP Percent Measured Bradycardia Measurements Since Last Counter Reset AP VS Percent Measured Bradycardia Measurements Since Last Counter Reset AS VS Percent Measured Bradycardia Measurements Since Last Counter Reset Right Atrium Percent Paced Measured Bradycardia Measurements Since Last Counter Reset Right Ventricle Percent Paced Path /EndDate /APVPPercent /ASVPPercent /APVSPercent /ASVSPercent /PercentPacedCollection/PercentPaced[Chamber='RIGHT_ATRIUM']/Percent /PercentPacedCollection/PercentPaced[Chamber='RIGHT_VENTRICLE']/ Percent
286 284 Connectivity Guide Paceart ML Schema Measured Bradycardia Measurements Since Last Counter Reset Left Ventricle Percent Paced Path /PercentPacedCollection/PercentPaced[Chamber='LEFT_VENTRICLE']/ Percent The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Detections_Therapies/ BradycardiaCollection/Bradycardia[Counter='LIFETIME']. Measured Bradycardia Measurements Lifetime Start Date Measured Bradycardia Measurements Lifetime End Date Measured Bradycardia Measurements Lifetime AP VP Percent Measured Bradycardia Measurements Lifetime AS VP Percent Measured Bradycardia Measurements Lifetime AP VS Percent Measured Bradycardia Measurements Lifetime AS VS Percent Path /StartDate /EndDate /APVPPercent /ASVPPercent /APVSPercent /ASVSPercent
287 Connectivity Guide Paceart ML Schema 285 Measured Bradycardia Measurements Lifetime Right Atrium Percent Paced Measured Bradycardia Measurements Lifetime Right Ventricle Percent Paced Measured Bradycardia Measurements Lifetime Left Ventricle Percent Paced Path /PercentPacedCollection/PercentPaced[Chamber='RIGHT_ATRIUM']/Percent /PercentPacedCollection/PercentPaced[Chamber='RIGHT_VENTRICLE']/ Percent /PercentPacedCollection/PercentPaced[Chamber='LEFT_VENTRICLE']/ Percent The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Detections_Therapies/ AtrialCollection/Atrial[Counter='SINCE_LA_SESSION']. Measured Atrial Counters Since Last Session Start Date Measured Atrial Counters Since Last Session End Date Measured Atrial Counters Since Last Session AT AF Burden Measured Atrial Counters Since Last Session Mode Switch Maximum Duration Measured Atrial Counters Since Last Session Mode Switch Count Measured Atrial Counters Since Last Session Mode Switch Burden Measured Atrial Counters Since Last Session Mode Switch Average Daily Count Measured Atrial Counters Since Last Session Mode Switch Average Daily Burden Path /StartDate /EndDate /ATAFBurden /ModeSwitch/MaximumDuration /ModeSwitch/Count /ModeSwitch/Burden /ModeSwitch/AverageDailyCount /ModeSwitch/AverageDailyBurden
288 286 Connectivity Guide Paceart ML Schema The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Detections_Therapies/ AtrialCollection/Atrial[Counter='SINCE_LA_COUNTER_RESET']. Measured Atrial Counters Since Last Counter Reset Start Date Measured Atrial Counters Since Last Counter Reset End Date Measured Atrial Counters Since Last Session AT AF Burden Measured Atrial Counters Since Last Counter Reset Mode Switch Maximum Duration Measured Atrial Counters Since Last Counter Reset Mode Switch Count Measured Atrial Counters Since Last Counter Reset Mode Switch Burden Measured Atrial Counters Since Last Counter Reset Mode Switch Average Daily Count Measured Atrial Counters Since Last Counter Reset Mode Switch Average Daily Burden Path /StartDate /EndDate /ATAFBurden /ModeSwitch/MaximumDuration /ModeSwitch/Count /ModeSwitch/Burden /ModeSwitch/AverageDailyCount /ModeSwitch/AverageDailyBurden The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Detections_Therapies/ AtrialCollection/Atrial[Counter='LIFETIME']. Measured Atrial Counters Lifetime Start Date Measured Atrial Counters Lifetime End Date Measured Atrial Counters Lifetime AT AF Burden Measured Atrial Counters Lifetime Mode Switch Maximum Duration Measured Atrial Counters Lifetime Mode Switch Count Measured Atrial Counters Lifetime Mode Switch Burden Measured Atrial Counters Lifetime Mode Switch Average Daily Count Path /StartDate /EndDate /ATAFBurden /ModeSwitch/MaximumDuration /ModeSwitch/Count /ModeSwitch/Burden /ModeSwitch/AverageDailyCount
289 Connectivity Guide Paceart ML Schema 287 Measured Atrial Counters Lifetime Mode Switch Average Daily Burden Path /ModeSwitch/AverageDailyBurden The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Detections_Therapies/ HeartFailureCollection/HeartFailure[Counter='SINCE_LA_SESSION']. Measured Heart Failure Counters Since Last Session Start Date Measured Heart Failure Counters Since Last Session End Date Measured Heart Failure Counters Since Last Session CRT Percent Paced Path /StartDate /EndDate /CRTPercentPaced The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Detections_Therapies/ HeartFailureCollection/HeartFailure[Counter='SINCE_LA_COUNTER_RESET']. Measured Heart Failure Counters Since Last Counter Reset Start Date Measured Heart Failure Counters Since Last Counter Reset End Date Measured Heart Failure Counters Since Last Counter Reset CRT Percent Paced Path /StartDate /EndDate /CRTPercentPaced The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Detections_Therapies/ HeartFailureCollection/HeartFailure[Counter='LIFETIME']. Measured Heart Failure Counters Lifetime Start Date Measured Heart Failure Counters Lifetime End Date Measured Heart Failure Counters Lifetime CRT Percent Paced Path /StartDate /EndDate /CRTPercentPaced The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Detections_Therapies/ DetectionsCollection/ Detections[Counter='SINCE_LA_SESSION'].
290 288 Connectivity Guide Paceart ML Schema Measured Detection Counters Since Last Session Start Date Measured Detection Counters Since Last Session End Date Measured Detection Counters Since Last Session Extended High Rate / Sustained High Rate Measured Detection Counters Since Last Session Single PVCs Measured Detection Counters Since Last Session Runs of PVCs Measured Detection Counters Since Last Session AF AT Episode Count Path /StartDate /EndDate /Other/ExtendedHighRate_SustainedHighRate /Other/SinglePVCs /Other/RunsOfPVCs /Episodes/Episode[='AF_AT']/Count Measured Detection Counters Since Last Session AF AT Monitor Episode Count /Episodes/Episode[='AF_AT_MONITOR']/ Count Measured Detection Counters Since Last Session A N Episode Count Measured Detection Counters Since Last Session Asystole Episode Count Measured Detection Counters Since Last Session AT Episode Count /Episodes/Episode[='A_N']/Count /Episodes/Episode[='ASYOLE']/Count /Episodes/Episode[='AT']/Count Measured Detection Counters Since Last Session AT Monitor Episode Count /Episodes/Episode[='AT_MONITOR']/ Count Measured Detection Counters Since Last Session Brady Episode Count Measured Detection Counters Since Last Session Brady Mode Switch Episode Count Measured Detection Counters Since Last Session Brady Rate Drop Response Episode Count /Episodes/Episode[='BRADY']/Count /Episodes/Episode[='BRADY_MS']/Count /Episodes/Episode[='BRADY_RDR']/Count
291 Connectivity Guide Paceart ML Schema 289 Measured Detection Counters Since Last Session Other Episode Count Measured Detection Counters Since Last Session Patient Activated Episode Count Measured Detection Counters Since Last Session Periodic Episode Count Measured Detection Counters Since Last Session SVT Episode Count Measured Detection Counters Since Last Session V N Episode Count Measured Detection Counters Since Last Session VF VT Episode Count Measured Detection Counters Since Last Session VF VT Monitor Episode Count Measured Detection Counters Since Last Session VT Episode Count Measured Detection Counters Since Last Session VT Monitor Episode Count Measured Detection Counters Since Last Session VT Episode Count Measured Detection Counters Since Last Session VT Monitor Episode Count Measured Detection Counters Since Last Session VT2 Episode Count Measured Detection Counters Since Last Session VT2 Monitor Episode Count Path /Episodes/Episode[='OTHER']/Count /Episodes/ Episode[='PATIENT_ACTIVATED']/Count /Episodes/Episode[='PERIODIC']/Count /Episodes/Episode[='SVT']/Count /Episodes/Episode[='V_N']/Count /Episodes/Episode[='VF_VT']/Count /Episodes/Episode[='VF_VT_MONITOR']/ Count /Episodes/Episode[='VT']/Count /Episodes/Episode[='VT_MONITOR']/ Count /Episodes/Episode[='VT']/Count /Episodes/Episode[='VT_MONITOR']/ Count /Episodes/Episode[='VT2']/Count /Episodes/Episode[='VT2_MONITOR']/ Count The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Detections_Therapies/ DetectionsCollection/ Detections[Counter='SINCE_LA_COUNTER_RESET'].
292 290 Connectivity Guide Paceart ML Schema Measured Detection Counters Since Last Counter Reset Start Date Measured Detection Counters Since Last Counter Reset End Date Measured Detection Counters Since Last Counter Reset Extended High Rate / Sustained High Rate Measured Detection Counters Since Last Counter Reset Single PVCs Measured Detection Counters Since Last Counter Reset Runs of PVCs Measured Detection Counters Since Last Counter Reset AF AT Episode Count Path /StartDate /EndDate /Other/ExtendedHighRate_SustainedHighRate /Other/SinglePVCs /Other/RunsOfPVCs /Episodes/Episode[='AF_AT']/Count Measured Detection Counters Since Last Counter Reset AF AT Monitor Episode Count /Episodes/Episode[='AF_AT_MONITOR']/ Count Measured Detection Counters Since Last Counter Reset A N Episode Count Measured Detection Counters Since Last Counter Reset Asystole Episode Count Measured Detection Counters Since Last Counter Reset AT Episode Count /Episodes/Episode[='A_N']/Count /Episodes/Episode[='ASYOLE']/Count /Episodes/Episode[='AT']/Count Measured Detection Counters Since Last Counter Reset AT Monitor Episode Count /Episodes/Episode[='AT_MONITOR']/ Count Measured Detection Counters Since Last Counter Reset Brady Episode Count Measured Detection Counters Since Last Counter Reset Brady Mode Switch Episode Count Measured Detection Counters Since Last Counter Reset Brady Rate Drop Response Episode Count /Episodes/Episode[='BRADY']/Count /Episodes/Episode[='BRADY_MS']/Count /Episodes/Episode[='BRADY_RDR']/Count
293 Connectivity Guide Paceart ML Schema 29 Measured Detection Counters Since Last Counter Reset Other Episode Count Measured Detection Counters Since Last Counter Reset Patient Activated Episode Count Measured Detection Counters Since Last Counter Reset Periodic Episode Count Measured Detection Counters Since Last Counter Reset SVT Episode Count Measured Detection Counters Since Last Counter Reset V N Episode Count Measured Detection Counters Since Last Counter Reset VF VT Episode Count Measured Detection Counters Since Last Counter Reset VF VT Monitor Episode Count Measured Detection Counters Since Last Counter Reset VT Episode Count Measured Detection Counters Since Last Counter Reset VT Monitor Episode Count Measured Detection Counters Since Last Counter Reset VT Episode Count Measured Detection Counters Since Last Counter Reset VT Monitor Episode Count Measured Detection Counters Since Last Counter Reset VT2 Episode Count Measured Detection Counters Since Last Counter Reset VT2 Monitor Episode Count Path /Episodes/Episode[='OTHER']/Count /Episodes/ Episode[='PATIENT_ACTIVATED']/Count /Episodes/Episode[='PERIODIC']/Count /Episodes/Episode[='SVT']/Count /Episodes/Episode[='V_N']/Count /Episodes/Episode[='VF_VT']/Count /Episodes/Episode[='VF_VT_MONITOR']/ Count /Episodes/Episode[='VT']/Count /Episodes/Episode[='VT_MONITOR']/ Count /Episodes/Episode[='VT']/Count /Episodes/Episode[='VT_MONITOR']/ Count /Episodes/Episode[='VT2']/Count /Episodes/Episode[='VT2_MONITOR']/ Count The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Detections_Therapies/ DetectionsCollection/Detections[Counter='LIFETIME']. Measured Detection Counters Lifetime Start Date Path /StartDate
294 292 Connectivity Guide Paceart ML Schema Measured Detection Counters Lifetime End Date Measured Detection Counters Lifetime Extended High Rate / Sustained High Rate Measured Detection Counters Lifetime Single PVCs Measured Detection Counters Lifetime Runs of PVCs Measured Detection Counters Lifetime AF AT Episode Count Measured Detection Counters Lifetime AF AT Monitor Episode Count Measured Detection Counters Lifetime A N Episode Count Measured Detection Counters Lifetime Asystole Episode Count Measured Detection Counters Lifetime AT Episode Count Measured Detection Counters Lifetime AT Monitor Episode Count Measured Detection Counters Lifetime Brady Episode Count Measured Detection Counters Lifetime Brady Mode Switch Episode Count Measured Detection Counters Lifetime Brady Rate Drop Response Episode Count Measured Detection Counters Lifetime Other Episode Count Measured Detection Counters Lifetime Patient Activated Episode Count Path /EndDate /Other/ExtendedHighRate_SustainedHighRate /Other/SinglePVCs /Other/RunsOfPVCs /Episodes/Episode[='AF_AT']/Count /Episodes/Episode[='AF_AT_MONITOR']/ Count /Episodes/Episode[='A_N']/Count /Episodes/Episode[='ASYOLE']/Count /Episodes/Episode[='AT']/Count /Episodes/Episode[='AT_MONITOR']/ Count /Episodes/Episode[='BRADY']/Count /Episodes/Episode[='BRADY_MS']/Count /Episodes/Episode[='BRADY_RDR']/Count /Episodes/Episode[='OTHER']/Count /Episodes/ Episode[='PATIENT_ACTIVATED']/Count
295 Connectivity Guide Paceart ML Schema 293 Measured Detection Counters Lifetime Periodic Episode Count Measured Detection Counters Lifetime SVT Episode Count Measured Detection Counters Lifetime V N Episode Count Measured Detection Counters Lifetime VF VT Episode Count Measured Detection Counters Lifetime VF VT Monitor Episode Count Measured Detection Counters Lifetime VT Episode Count Measured Detection Counters Lifetime VT Monitor Episode Count Measured Detection Counters Lifetime VT Episode Count Measured Detection Counters Lifetime VT Monitor Episode Count Measured Detection Counters Lifetime VT2 Episode Count Measured Detection Counters Lifetime VT2 Monitor Episode Count Path /Episodes/Episode[='PERIODIC']/Count /Episodes/Episode[='SVT']/Count /Episodes/Episode[='V_N']/Count /Episodes/Episode[='VF_VT']/Count /Episodes/Episode[='VF_VT_MONITOR']/ Count /Episodes/Episode[='VT']/Count /Episodes/Episode[='VT_MONITOR']/ Count /Episodes/Episode[='VT']/Count /Episodes/Episode[='VT_MONITOR']/ Count /Episodes/Episode[='VT2']/Count /Episodes/Episode[='VT2_MONITOR']/ Count The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Detections_Therapies/ TherapiesCollection/Therapies[Counter='SINCE_LA_SESSION']. Measured Counters Since Last Session Start Date Measured Path /StartDate /EndDate
296 294 Connectivity Guide Paceart ML Schema Counters Since Last Session End Date Measured Counters Since Last Session Right Atrium s Delivered Measured Counters Since Last Session Right Atrium s Aborted Measured Counters Since Last Session Right Atrium ATP Delivered Measured Counters Since Last Session Right Ventricle s Delivered Measured Counters Since Last Session Right Ventricle s Aborted Measured Counters Since Last Session Right Path /Therapies/[Chamber='RIGHT_ATRIUM']/s/Delivered /Therapies/[Chamber='RIGHT_ATRIUM']/s/Aborted /Therapies/[Chamber='RIGHT_ATRIUM']/ATP/Delivered /Therapies/[Chamber='RIGHT_VENTRICLE']/s/Delivered /Therapies/[Chamber='RIGHT_VENTRICLE']/s/Aborted /Therapies/[Chamber='RIGHT_VENTRICLE']/ATP/Delivered
297 Connectivity Guide Paceart ML Schema 295 Ventricle ATP Delivered Measured Counters Since Last Session Left Ventricle s Delivered Measured Counters Since Last Session Left Ventricle s Aborted Measured Counters Since Last Session Left Ventricle ATP Delivered Path /Therapies/[Chamber='LEFT_VENTRICLE']/s/Delivered /Therapies/[Chamber='LEFT_VENTRICLE']/s/Aborted /Therapies/[Chamber=' LEFT_VENTRICLE']/ATP/Delivered The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Detections_Therapies/ TherapiesCollection/ Therapies[Counter='SINCE_LA_COUNTER_RESET']. Measured Counters Since Last Counter Reset Start Date Measured Counters Since Last Counter Reset End Date Measured Counters Since Last Counter Path /StartDate /EndDate /Therapies/[Chamber='RIGHT_ATRIUM']/s/Delivered
298 296 Connectivity Guide Paceart ML Schema Reset Right Atrium s Delivered Measured Counters Since Last Counter Reset Right Atrium s Aborted Measured Counters Since Last Counter Reset Right Atrium ATP Delivered Measured Counters Since Last Counter Reset Right Ventricle s Delivered Measured Counters Since Last Counter Reset Right Ventricle s Aborted Measured Counters Since Last Counter Reset Right Ventricle ATP Delivered Measured Counters Since Last Counter Reset Left Ventricle s Delivered Measured Path /Therapies/[Chamber='RIGHT_ATRIUM']/s/Aborted /Therapies/[Chamber='RIGHT_ATRIUM']/ATP/Delivered /Therapies/[Chamber='RIGHT_VENTRICLE']/s/Delivered /Therapies/[Chamber='RIGHT_VENTRICLE']/s/Aborted /Therapies/[Chamber='RIGHT_VENTRICLE']/ATP/Delivered /Therapies/[Chamber='LEFT_VENTRICLE']/s/Delivered /Therapies/[Chamber='LEFT_VENTRICLE']/s/Aborted
299 Connectivity Guide Paceart ML Schema 297 Counters Since Last Counter Reset Left Ventricle s Aborted Measured Counters Since Last Counter Reset Left Ventricle ATP Delivered Path /Therapies/[Chamber=' LEFT_VENTRICLE']/ATP/Delivered The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Detections_Therapies/ TherapiesCollection/Therapies[Counter='LIFETIME']. Measured Counters Lifetime Start Date Measured Counters Lifetime End Date Measured Counters Lifetime Right Atrium s Delivered Measured Counters Lifetime Right Atrium s Aborted Measured Counters Lifetime Right Atrium ATP Delivered Path /StartDate /EndDate /Therapies/[Chamber='RIGHT_ATRIUM']/s/Delivered /Therapies/[Chamber='RIGHT_ATRIUM']/s/Aborted /Therapies/[Chamber='RIGHT_ATRIUM']/ATP/Delivered
300 298 Connectivity Guide Paceart ML Schema Measured Counters Lifetime Right Ventricle s Delivered Measured Counters Lifetime Right Ventricle s Aborted Measured Counters Lifetime Right Ventricle ATP Delivered Measured Counters Lifetime Left Ventricle s Delivered Measured Counters Lifetime Left Ventricle s Aborted Measured Counters Lifetime Left Ventricle ATP Delivered Path /Therapies/[Chamber='RIGHT_VENTRICLE']/s/Delivered /Therapies/[Chamber='RIGHT_VENTRICLE']/s/Aborted /Therapies/[Chamber='RIGHT_VENTRICLE']/ATP/Delivered /Therapies/[Chamber='LEFT_VENTRICLE']/s/Delivered /Therapies/[Chamber='LEFT_VENTRICLE']/s/Aborted /Therapies/[Chamber=' LEFT_VENTRICLE']/ATP/Delivered The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Leads/Lead[Chamber='RIGHT_ATRIUM']/ LowPowerChannel/SensitivityCollections/SensitivityCollection. Measured Right Atrium Lead Path /Id
301 Connectivity Guide Paceart ML Schema 299 Sensing Threshold Collection Id Measured Right Atrium Lead Sensing Threshold Measurement Method Measured Right Atrium Lead Sensing Threshold Method Variance Measured Right Atrium Lead Sensing Threshold Polarity Path /Method /Method_Variance /PolarityConfiguration/Polarity Measured Right Atrium Lead Sensing Threshold Polarity Measured Right Atrium Lead Sensing Threshold Measured Right Atrium Lead Sensing Threshold Measured Right Atrium Lead Sensing Threshold Id Measured Right Atrium Lead Sensing Threshold Start Date Measured Right Atrium Lead Sensing Threshold End Date /PolarityConfiguration/s//Pole/ /PolarityConfiguration/s//Pole/ /PolarityConfiguration/s//Pole/ /Sensitivities/Sensitivity/Id /Sensitivities/Sensitivity/StartDate /Sensitivities/Sensitivity/EndDate
302 300 Connectivity Guide Paceart ML Schema Measured Right Atrium Lead Sensing Threshold Measurement Measured Right Atrium Lead Sensing Threshold Amplitude Path /Sensitivities/Sensitivity/MeasurementCollection/Measurement/ /Sensitivities/Sensitivity/MeasurementCollection/Measurement/Amplitude The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Leads/Lead[Chamber='RIGHT_VENTRICLE']/ LowPowerChannel/SensitivityCollections/SensitivityCollection. Measured Right Ventricle Lead Sensing Threshold Collection Id Measured Right Ventricle Lead Sensing Threshold Measurement Method Measured Right Ventricle Lead Sensing Threshold Method Variance Measured Right Ventricle Lead Sensing Threshold Polarity Measured Right Ventricle Lead Sensing Threshold Polarity Measured Right Ventricle Lead Sensing Threshold Measured Right Ventricle Lead Sensing Threshold Measured Right Ventricle Lead Sensing Threshold Id Path /Id /Method /Method_Variance /PolarityConfiguration/Polarity /PolarityConfiguration/s//Pole/ /PolarityConfiguration/s//Pole/ /PolarityConfiguration/s//Pole/ /Sensitivities/Sensitivity/Id
303 Connectivity Guide Paceart ML Schema 30 Measured Right Ventricle Lead Sensing Threshold Start Date Measured Right Ventricle Lead Sensing Threshold End Date Measured Right Ventricle Lead Sensing Threshold Measurement Measured Right Ventricle Lead Sensing Threshold Amplitude Path /Sensitivities/Sensitivity/StartDate /Sensitivities/Sensitivity/EndDate /Sensitivities/Sensitivity/MeasurementCollection/Measurement/ /Sensitivities/Sensitivity/MeasurementCollection/Measurement/Amplitude The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Leads/Lead[Chamber='LEFT_VENTRICLE']/ LowPowerChannel/SensitivityCollections/SensitivityCollection. Measured Left Ventricle Lead Sensing Threshold Collection Id Measured Left Ventricle Lead Sensing Threshold Measurement Method Measured Left Ventricle Lead Sensing Threshold Method Variance Measured Left Ventricle Lead Sensing Threshold Polarity Measured Left Ventricle Lead Sensing Threshold Polarity Measured Left Ventricle Lead Sensing Threshold Path /Id /Method /Method_Variance /PolarityConfiguration/Polarity /PolarityConfiguration/s//Pole/ /PolarityConfiguration/s//Pole/
304 302 Connectivity Guide Paceart ML Schema Measured Left Ventricle Lead Sensing Threshold Measured Left Ventricle Lead Sensing Threshold Id Measured Left Ventricle Lead Sensing Threshold Start Date Measured Left Ventricle Lead Sensing Threshold End Date Measured Left Ventricle Lead Sensing Threshold Measurement Measured Left Ventricle Lead Sensing Threshold Amplitude Path /PolarityConfiguration/s//Pole/ /Sensitivities/Sensitivity/Id /Sensitivities/Sensitivity/StartDate /Sensitivities/Sensitivity/EndDate /Sensitivities/Sensitivity/MeasurementCollection/Measurement/ /Sensitivities/Sensitivity/MeasurementCollection/Measurement/Amplitude The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Leads/Lead[Chamber='RIGHT_ATRIUM']/ LowPowerChannel/CaptureCollections/CaptureCollection. Measured Right Atrium Lead Capture Threshold Collection Id Measured Right Atrium Lead Capture Threshold Measurement Method Measured Right Atrium Lead Capture Threshold Method Variance Measured Right Atrium Lead Capture Threshold Polarity Path /Id /Method /Method_Variance /PolarityConfiguration/Polarity
305 Connectivity Guide Paceart ML Schema 303 Measured Right Atrium Lead Capture Threshold Polarity Measured Right Atrium Lead Capture Threshold Measured Right Atrium Lead Capture Threshold Measured Right Atrium Lead Capture Threshold Id Measured Right Atrium Lead Capture Threshold Start Date Measured Right Atrium Lead Capture Threshold End Date Measured Right Atrium Lead Capture Threshold Amplitude Measured Right Atrium Lead Capture Threshold Duration Path /PolarityConfiguration/s//Pole/ /PolarityConfiguration/s//Pole/ /PolarityConfiguration/s//Pole/ /Captures/Capture/Id /Captures/Capture/StartDate /Captures/Capture/EndDate /Captures/Capture/Amplitude /Captures/Capture/Duration The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Leads/Lead[Chamber='RIGHT_VENTRICLE']/ LowPowerChannel/CaptureCollections/CaptureCollection. Measured Right Ventricle Lead Capture Threshold Collection Id Measured Right Ventricle Lead Capture Threshold Measurement Method Path /Id /Method
306 304 Connectivity Guide Paceart ML Schema Measured Right Ventricle Lead Capture Threshold Method Variance Measured Right Ventricle Lead Capture Threshold Polarity Measured Right Ventricle Lead Capture Threshold Polarity Measured Right Ventricle Lead Capture Threshold Measured Right Ventricle Lead Capture Threshold Measured Right Ventricle Lead Capture Threshold Id Measured Right Ventricle Lead Capture Threshold Start Date Measured Right Ventricle Lead Capture Threshold End Date Measured Right Ventricle Lead Capture Threshold Amplitude Measured Right Ventricle Lead Path /Method_Variance /PolarityConfiguration/Polarity /PolarityConfiguration/s//Pole/ /PolarityConfiguration/s//Pole/ /PolarityConfiguration/s//Pole/ /Captures/Capture/Id /Captures/Capture/StartDate /Captures/Capture/EndDate /Captures/Capture/Amplitude /Captures/Capture/Duration
307 Connectivity Guide Paceart ML Schema 305 Capture Threshold Duration Path The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Statistics/Leads/Lead[Chamber='LEFT_VENTRICLE']/ LowPowerChannel/CaptureCollections/CaptureCollection. Measured Left Ventricle Lead Capture Threshold Collection Id Measured Left Ventricle Lead Capture Threshold Measurement Method Measured Left Ventricle Lead Capture Threshold Method Variance Measured Left Ventricle Lead Capture Threshold Polarity Measured Left Ventricle Lead Capture Threshold Polarity Measured Left Ventricle Lead Capture Threshold Measured Left Ventricle Lead Capture Threshold Measured Left Ventricle Lead Capture Threshold Id Path /Id /Method /Method_Variance /PolarityConfiguration/Polarity /PolarityConfiguration/s//Pole/ /PolarityConfiguration/s//Pole/ /PolarityConfiguration/s//Pole/ /Captures/Capture/Id
308 306 Connectivity Guide Paceart ML Schema Measured Left Ventricle Lead Capture Threshold Start Date Measured Left Ventricle Lead Capture Threshold End Date Measured Left Ventricle Lead Capture Threshold Amplitude Measured Left Ventricle Lead Capture Threshold Duration Path /Captures/Capture/StartDate /Captures/Capture/EndDate /Captures/Capture/Amplitude /Captures/Capture/Duration The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Programming//Zones/Zone. Zone Zone Committed Path / /SharedSettings/Committed The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Programming//Zones/Zone/Detections. Zone Detection Status Zone Detection Interval Path /Status /Detection/Criteria/Interval /Detection/Criteria/Duration/Shared/Fixed
309 Connectivity Guide Paceart ML Schema 307 Zone Shared Detection Duration Fixed Zone Shared Detection Duration Beat Count Zone Shared Detection Duration Beat Ratio Numerator Zone Shared Detection Duration Beat Ratio Denominator Zone ATP Detection Duration Fixed Zone ATP Detection Duration Beat Count Zone ATP Detection Duration Beat Ratio Numerator Zone ATP Detection Path /Detection/Criteria/Duration/Shared/BeatCount /Detection/Criteria/Duration/Shared/BeatRatio/Numerator /Detection/Criteria/Duration/Shared/BeatRatio/Denominator /Detection/Criteria/Duration/Specific/ATP/Fixed /Detection/Criteria/Duration/Specific/ATP/BeatCount /Detection/Criteria/Duration/Specific/ATP/BeatRatio/Numerator /Detection/Criteria/Duration/Specific/ATP/BeatRatio/Denominator
310 308 Connectivity Guide Paceart ML Schema Duration Beat Ratio Denominator Zone Detection Duration Fixed Zone Detection Duration Beat Count Zone Detection Duration Beat Ratio Numerator Zone Detection Duration Beat Ratio Denominator Zone Redetection Interval Zone Shared Redetection Duration Fixed Zone Shared Redetection Duration Beat Count Path /Detection/Criteria/Duration/Specific//Fixed /Detection/Criteria/Duration/Specific//BeatCount /Detection/Criteria/Duration/Specific//BeatRatio/Numerator /Detection/Criteria/Duration/Specific//BeatRatio/Denominator /Redetection/Criteria/Interval /Redetection/Criteria/Duration/Shared/Fixed /Redetection/Criteria/Duration/Shared/BeatCount
311 Connectivity Guide Paceart ML Schema 309 Zone Shared Redetection Duration Beat Ratio Numerator Zone Shared Redetection Duration Beat Ratio Denominator Zone ATP Redetection Duration Fixed Zone ATP Redetection Duration Beat Count Zone ATP Redetection Duration Beat Ratio Numerator Zone ATP Redetection Duration Beat Ratio Denominator Zone Redetection Duration Fixed Path /Redetection/Criteria/Duration/Shared/BeatRatio/Numerator /Redetection/Criteria/Duration/Shared/BeatRatio/Denominator /Redetection/Criteria/Duration/Specific/ATP/Fixed /Redetection/Criteria/Duration/Specific/ATP/BeatCount /Redetection/Criteria/Duration/Specific/ATP/BeatRatio/Numerator /Redetection/Criteria/Duration/Specific/ATP/BeatRatio/Denominator /Redetection/Criteria/Duration/Specific//Fixed
312 30 Connectivity Guide Paceart ML Schema Zone Redetection Duration Beat Count Zone Redetection Duration Beat Ratio Numerator Zone Redetection Duration Beat Ratio Denominator Zone Sudden Onset Status Zone Sudden Onset Duration Fixed Zone Sudden Onset Duration Percent Zone Rate Stability Status Zone Rate Stability Duration Path /Redetection/Criteria/Duration/Specific//BeatCount /Redetection/Criteria/Duration/Specific//BeatRatio/Numerator /Redetection/Criteria/Duration/Specific//BeatRatio/Denominator /SuddenOnset/Status /SuddenOnset/Criteria/Duration/Fixed /SuddenOnset/Criteria/Duration/Percent /RateStability/Status /RateStability/Criteria/Duration
313 Connectivity Guide Paceart ML Schema 3 Zone Sustained High Rate To Current Zone Status Zone Sustained High Rate To Current Zone Duration Zone Sustained High Rate To Current Zone Rate Zone Sustained High Rate To VF Zone Status Zone Sustained High Rate To VF Zone Duration Zone Sustained High Rate To VF Zone Rate Zone QRS Morphology Status Zone QRS Path /SustainedHighRateToCurrentZone/Status /SustainedHighRateToCurrentZone/Criteria/Duration /SustainedHighRateToCurrentZone/Criteria/Rate /SustainedHighRateToVFZone/Status /SustainedHighRateToVFZone/Criteria/Duration /SustainedHighRateToVFZone/Criteria/Rate /QRSMorphology/Status /QRSMorphology/Criteria/Match
314 32 Connectivity Guide Paceart ML Schema Morphology Match Zone Classifier Path /Classifier The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Programming//Zones/Zone/Therapies/. Sequence ID Status Description Timing Amplitude Pulse Width Stimuli Count Coupling Interval Length Fixed Coupling Interval Length Percent Coupling Interval Decrement Ramp Decrement Minimum Burst Cycle Length Number Of Sequences Maximum Number Of Pulses Path /SequenceID /Status /ATP/ /ATP/Description /ATP/Timing /ATP/Amplitude /ATP/PulseWidth /ATP/StimuliCount /ATP/CouplingIntervalLength/ Fixed /ATP/CouplingIntervalLength/ Percent /ATP/ CouplingIntervalDecrement /ATP/RampDecrement /ATP/ MinimumBurstCycleLength /ATP/NumberOfSequences /ATP/ MaximumNumberOfPulses
315 Connectivity Guide Paceart ML Schema 33 Pulse Increment Scan Decrement Smart Mode Disabled By Smart Mode Burst Cycle Length Fixed Burst Cycle Length Percent SS2 Ramp Percent S2SN Ramp Percent Scan Sequence Sequence ID Status Energy Voltage Waveform Polarity Cardioversion Delay Pulse Width Negative Pulse Width Positive Tilt Negative Path /ATP/PulseIncrement /ATP/ScanDecrement /ATP/SmartMode /ATP/ DisabledBySmartMode /ATP/BurstCycleLengthFixed /ATP/ BurstCycleLengthPercent /ATP/SS2RampPercent /ATP/S2SNRampPercent /ATP/ScanSequence /SequenceID /Status //Energy //Voltage //Waveform //s// Pole/ //s// Pole/ //s// Pole/ //CardioversionDelay //PulseWidthNegative //PulseWidthPositive //TiltNegative Integer
316 34 Connectivity Guide Paceart ML Schema Tilt Positive Path //TiltPositive Episodes The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Episodes. Episodes Last Cleared Date Episodes Last Interrogation Date Path /EpisodesLastClearedDate /EpisodesLastInterrogationDate The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Episodes/EpisodeCollection/Episode. Episodes Episode Id Episodes Episode Episodes Episode Start Episodes Episode Duration Episodes Episode Number of ATP Sequences Delivered Episodes Episode Number of s Delivered Episodes Episode Result Episodes Episode Average Atrial Rate Episodes Episode Average Ventricular Rate Episodes Episode Maximum Atrial Rate Episodes Episode Maximum Ventricular Rate Episodes Episode Activity at Onset Path /Id / /Start /Duration /NumberOfATPSequencesDelivered /NumberOfsDelivered /Result /AverageAtrialRate /AverageVentricularRate /MaximumAtrialRate /MaximumVentricularRate /ActivityAtOnset The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Episodes/Episodecollection/Episode/ ExtendedDataCollection/Data. Episodes Episode Data Name Episodes Episode Data Value Path /Name /Value String 00
317 Connectivity Guide Paceart ML Schema 35 The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Episodes/Episodecollection/Episode/Strips/Strip. Waveform Strip Id Waveform Strip Start Date Waveform Strip Duration Waveform Strip Label Waveform Strip Derivation Path /Id /Start /Duration /Label / The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Episodes/Episodecollection/Episode/Strips/Strip/ Waveforms/Waveform. Waveform Channel Id Path /Id The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Episodes/Episodecollection/Episode/Strips/Strip/ Waveforms/Waveform/Source/Sample. Waveform Sample Amplitude Origin Waveform Sample Interval Path /AmplitudeOrigin /Interval The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Episodes/Episodecollection/Episode/Strips/Strip/ Waveforms/Waveform/Source. Waveform Segment Offset Waveform Segment Length Waveform Segment Sample Value Path /Offset /Length /SampleValues The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Episodes/Episodecollection/Episode/Strips/Strip/ Annotations/Segments/Segment. Waveform Annotation Segment Offset Path /Offset
318 36 Connectivity Guide Paceart ML Schema Waveform Annotation Segment Length Path /Length The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Episodes/Episodecollection/Episode/Strips/Strip/ Annotations/Segments/Segment/Annotations/Annotation. Waveform Annotation Waveform Annotation Offset Waveform Annotation Timestamp Waveform Annotation AA Interval Waveform Annotation VA Interval Waveform Annotation VV Interval Waveform Annotation AV Interval Waveform Annotation A Interval Waveform Annotation V Interval Waveform Annotation PW Interval Path / /Offset /Timestamp /Intervals/AA /Intervals/VA /Intervals/VV /Intervals/AV /Intervals/A /Intervals/V /Intervals/PW The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Episodes/Episodecollection/Episode/Strips/Strip/ Waveforms/Waveform/Source/Signal/ElectricPotential. Waveform Electric Potential Channel Amplitude Scale Waveform Electric Potential Channel Amplitude Origin Waveform Electric Potential Channel Polarity Waveform Electric Potential Channel Polarity Waveform Electric Potential Channel Path /AmplitudeScale /AmplitudeOrigin //EGM/PolarityConfiguration/Polarity //EGM/ PolarityConfiguration/ s//pole/ //EGM/ PolarityConfiguration/ s//pole/
319 Connectivity Guide Paceart ML Schema 37 Waveform Electric Potential Channel Path //EGM/ PolarityConfiguration/ s//pole/ The root path in the ML output for the following table is /PaceartML/PatientRecord/s/ /InterrogatedDeviceData/Episodes/Episodecollection/Episode/Strips/Strip/ Waveforms/Waveform/Source/Signal/Unspecified. Waveform Unspecified Channel Amplitude Scale Waveform Unspecified Channel Amplitude Origin Waveform Unspecified Channel Description Path /AmplitudeScale /AmplitudeOrigin //Description
320
321
322 Manufacturer Medtronic, Inc. 70 Medtronic Parkway Minneapolis, MN USA Tel.: Fax: Europe/Africa/Middle East Headquarters Medtronic International Trading Sàrl Route du Molliau 3 Case Postale 84 CH-3 Tolochenaz Switzerland Tel.: Fax: Medtronic E.C. Authorized Representative/Distributed by Medtronic B. V. Earl Bakkenstraat PJ Heerlen The Netherlands Tel.: Fax: Australia/New Zealand Medtronic Australasia Pty. Ltd. 97 Waterloo Road North Ryde NSW 23 Australia Canada Medtronic of Canada Ltd Kitiamat Road Mississauga Ontario L5N W3 Tel.: Fax: Toll-free in Canada: Medtronic, Inc. 20 M942A00 Rev A *M942A00*
MAINSPRING DATA EXPRESS
MAINSPRING DATA EXPRESS MDTCSG2 Version 4.0 CareLink Integration Software Installation and Configuration Manual Caution: Federal law (USA) restricts this device to sale by or on the order of a physician
WhatsUp Gold v16.1 Installation and Configuration Guide
WhatsUp Gold v16.1 Installation and Configuration Guide Contents Installing and Configuring Ipswitch WhatsUp Gold v16.1 using WhatsUp Setup Installing WhatsUp Gold using WhatsUp Setup... 1 Security guidelines
STATISTICA VERSION 10 STATISTICA ENTERPRISE SERVER INSTALLATION INSTRUCTIONS
Notes: STATISTICA VERSION 10 STATISTICA ENTERPRISE SERVER INSTALLATION INSTRUCTIONS 1. The installation of the STATISTICA Enterprise Server entails two parts: a) a server installation, and b) workstation
Connecting Cardiac Device Data and the EHR
Learn More Interested in learning more about how Paceart s device management functionality can work in an EHR environment and help you in your move toward the paperless transfer of data? Connecting Cardiac
Sophos Enterprise Console server to server migration guide. Product version: 5.1 Document date: June 2012
Sophos Enterprise Console server to server migration guide Product : 5.1 Document date: June 2012 Contents 1 About this guide...3 2 Terminology...4 3 Assumptions...5 4 Prerequisite...6 5 What are the key
Connecting Cardiac Device Data and the EHR
Connecting Cardiac Device Data and the EHR Introduction In an age of complex information needs, healthcare providers often use a staggering variety of applications to capture a patient s complete clinical
WhatsUp Gold v16.2 Installation and Configuration Guide
WhatsUp Gold v16.2 Installation and Configuration Guide Contents Installing and Configuring Ipswitch WhatsUp Gold v16.2 using WhatsUp Setup Installing WhatsUp Gold using WhatsUp Setup... 1 Security guidelines
Bitrix Site Manager ASP.NET. Installation Guide
Bitrix Site Manager ASP.NET Installation Guide Contents Introduction... 4 Chapter 1. Checking for IIS Installation... 5 Chapter 2. Using An Archive File to Install Bitrix Site Manager ASP.NET... 7 Preliminary
Retail Deployment Guide. Microsoft Dynamics AX 2012 Feature Pack
Retail Deployment Guide Microsoft Dynamics AX 2012 Feature Pack Microsoft Corporation February 2012 Microsoft Dynamics is a line of integrated, adaptable business management solutions that enables you
WhatsUp Gold v16.2 MSP Edition Deployment Guide This guide provides information about installing and configuring WhatsUp Gold MSP Edition to central
WhatsUp Gold v16.2 MSP Edition Deployment Guide This guide provides information about installing and configuring WhatsUp Gold MSP Edition to central and remote sites. Contents Table of Contents Using WhatsUp
SAS Activity-Based Management Server Software Release 6.0 for Windows
Installation Instructions SAS Activity-Based Management Server Software Release 6.0 for Windows This document provides the instructions for installing SAS Activity-Based Management Server. You must update
8.7. NET SatisFAXtion Email Gateway Installation Guide. For NET SatisFAXtion 8.7. Contents
NET SatisFAXtion Email Gateway Installation Guide For NET SatisFAXtion 8.7 Contents Install Microsoft Virtual SMTP Server 2 XP and 2003 2 2008 and 2008 R2 2 Windows 7 2 Upgrade Path 2 Configure Microsoft
Sage 200 Web Time & Expenses Guide
Sage 200 Web Time & Expenses Guide Sage (UK) Limited Copyright Statement Sage (UK) Limited, 2006. All rights reserved If this documentation includes advice or information relating to any matter other than
Sophos Enterprise Console server to server migration guide. Product version: 5.2
Sophos Enterprise Console server to server migration guide Product : 5.2 Document date: December 2014 Contents 1 About this guide...3 2 Terminology...4 3 Assumptions...5 4 Prerequisite...6 5 What are the
Kaseya Server Instal ation User Guide June 6, 2008
Kaseya Server Installation User Guide June 6, 2008 About Kaseya Kaseya is a global provider of IT automation software for IT Solution Providers and Public and Private Sector IT organizations. Kaseya's
Software Version 1.0 ConnectKey TM Share to Cloud April 2013. Xerox ConnectKey Share to Cloud User / Administrator s Guide
Software Version 1.0 ConnectKey TM Share to Cloud April 2013 Xerox ConnectKey Share to Cloud User / Administrator s Guide 2013 Xerox Corporation. All rights reserved. Xerox, Xerox and Design, and Xerox
Note: Files contained within the root of My Files & Folders will always be synced.
New in this release: Selective Sync Users can now choose which top level folders within My Files & Folders they would like to sync, giving flexibility over the amount of disk space consumed by ShareFile.
NovaBACKUP xsp Version 12.2 Upgrade Guide
NovaBACKUP xsp Version 12.2 Upgrade Guide NovaStor / August 2011 Rev 20110815 2011 NovaStor, all rights reserved. All trademarks are the property of their respective owners. Features and specifications
0651 Installing PointCentral 8.0 For the First Time
Prerequisites Microsoft Windows Server 2003 or Windows Server 2008 Microsoft.NET Framework 4 Microsoft SQL Server 2005 or SQL Server 2008 IIS **For Windows Server 2003. You must manually configure IIS6
WhatsUp Gold v16.3 Installation and Configuration Guide
WhatsUp Gold v16.3 Installation and Configuration Guide Contents Installing and Configuring WhatsUp Gold using WhatsUp Setup Installation Overview... 1 Overview... 1 Security considerations... 2 Standard
Installation Guide. Novell Storage Manager 3.1.1 for Active Directory. Novell Storage Manager 3.1.1 for Active Directory Installation Guide
Novell Storage Manager 3.1.1 for Active Directory Installation Guide www.novell.com/documentation Installation Guide Novell Storage Manager 3.1.1 for Active Directory October 17, 2013 Legal Notices Condrey
Intelli-M Access Quick Start Guide
Intelli-M Access Quick Start Guide Before You Begin The Intelli-M Access software can be used in conjunction with the eidc. Use Intelli-M Access to manage, view, and report activity through an eidc controlled
Embarcadero Performance Center 2.7 Installation Guide
Embarcadero Performance Center 2.7 Installation Guide Copyright 1994-2009 Embarcadero Technologies, Inc. Embarcadero Technologies, Inc. 100 California Street, 12th Floor San Francisco, CA 94111 U.S.A.
File Management Utility User Guide
File Management Utility User Guide Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held
TOSHIBA GA-1310. Printing from Windows
TOSHIBA GA-1310 Printing from Windows 2009 Electronics for Imaging, Inc. The information in this publication is covered under Legal Notices for this product. 45081979 04 February 2009 CONTENTS 3 CONTENTS
LifeSize Control Installation Guide
LifeSize Control Installation Guide April 2005 Part Number 132-00001-001, Version 1.0 Copyright Notice Copyright 2005 LifeSize Communications. All rights reserved. LifeSize Communications has made every
Operating System Installation Guide
Operating System Installation Guide This guide provides instructions on the following: Installing the Windows Server 2008 operating systems on page 1 Installing the Windows Small Business Server 2011 operating
Operating Instructions Driver Installation Guide
Operating Instructions Driver Installation Guide For safe and correct use, be sure to read the Safety Information in "Read This First" before using the machine. TABLE OF CONTENTS 1. Introduction Before
PigCHAMP Knowledge Software. Enterprise Edition Installation Guide
PigCHAMP Knowledge Software Enterprise Edition Installation Guide Enterprise Edition Installation Guide MARCH 2012 EDITION PigCHAMP Knowledge Software 1531 Airport Rd Suite 101 Ames, IA 50010 Phone (515)
Archive Attender Version 3.5
Archive Attender Version 3.5 Getting Started Guide Sherpa Software (800) 255-5155 www.sherpasoftware.com Page 1 Under the copyright laws, neither the documentation nor the software can be copied, photocopied,
QUANTIFY INSTALLATION GUIDE
QUANTIFY INSTALLATION GUIDE Thank you for putting your trust in Avontus! This guide reviews the process of installing Quantify software. For Quantify system requirement information, please refer to the
Practice Fusion API Client Installation Guide for Windows
Practice Fusion API Client Installation Guide for Windows Quickly and easily connect your Results Information System with Practice Fusion s Electronic Health Record (EHR) System Table of Contents Introduction
DocAve Upgrade Guide. From Version 4.1 to 4.5
DocAve Upgrade Guide From Version 4.1 to 4.5 About This Guide This guide is intended for those who wish to update their current version of DocAve 4.1 to the latest DocAve 4.5. It is divided into two sections:
Issue Tracking Anywhere Installation Guide
TM Issue Tracking Anywhere Installation Guide The leading developer of version control and issue tracking software Table of Contents Introduction...3 Installation Guide...3 Installation Prerequisites...3
Sharp Remote Device Manager (SRDM) Server Software Setup Guide
Sharp Remote Device Manager (SRDM) Server Software Setup Guide This Guide explains how to install the software which is required in order to use Sharp Remote Device Manager (SRDM). SRDM is a web-based
User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream
User Manual Onsight Management Suite Version 5.1 Another Innovation by Librestream Doc #: 400075-06 May 2012 Information in this document is subject to change without notice. Reproduction in any manner
HYPERION SYSTEM 9 N-TIER INSTALLATION GUIDE MASTER DATA MANAGEMENT RELEASE 9.2
HYPERION SYSTEM 9 MASTER DATA MANAGEMENT RELEASE 9.2 N-TIER INSTALLATION GUIDE P/N: DM90192000 Copyright 2005-2006 Hyperion Solutions Corporation. All rights reserved. Hyperion, the Hyperion logo, and
CoCreate Manager Server Installation Guide. CoCreate Manager Server Installation Guide 1
CoCreate Manager Server Installation Guide CoCreate Manager Server Installation Guide 1 CoCreate Manager Server Installation Guide 2 Table Of Contents 1. CoCreate Manager Server 2008 4 1.1. Installation
Diamond II v2.3 Service Pack 4 Installation Manual
Diamond II v2.3 Service Pack 4 Installation Manual P/N 460987001B ISS 26APR11 Copyright Disclaimer Trademarks and patents Intended use Software license agreement FCC compliance Certification and compliance
Installation & Configuration Guide
Installation & Configuration Guide Bluebeam Studio Enterprise ( Software ) 2014 Bluebeam Software, Inc. All Rights Reserved. Patents Pending in the U.S. and/or other countries. Bluebeam and Revu are trademarks
Microsoft Dynamics GP Release
Microsoft Dynamics GP Release Workflow Installation and Upgrade Guide February 17, 2011 Copyright Copyright 2011 Microsoft. All rights reserved. Limitation of liability This document is provided as-is.
Customer admin guide. UC Management Centre
Customer admin guide UC Management Centre June 2013 Contents 1. Introduction 1.1 Logging into the UC Management Centre 1.2 Language Options 1.3 Navigating Around the UC Management Centre 4 4 5 5 2. Customers
8.6. NET SatisFAXtion Email Gateway Installation Guide. For NET SatisFAXtion 8.6. Contents
NET SatisFAXtion Email Gateway Installation Guide For NET SatisFAXtion 8.6 Contents 1.0 - Install Microsoft Virtual SMTP Server 2 XP and 2003 2 2008 and 2008 R2 2 Windows 7 2 Upgrade Path 2 Configure Microsoft
Metalogix SharePoint Backup. Advanced Installation Guide. Publication Date: August 24, 2015
Metalogix SharePoint Backup Publication Date: August 24, 2015 All Rights Reserved. This software is protected by copyright law and international treaties. Unauthorized reproduction or distribution of this
How To Create An Easybelle History Database On A Microsoft Powerbook 2.5.2 (Windows)
Introduction EASYLABEL 6 has several new features for saving the history of label formats. This history can include information about when label formats were edited and printed. In order to save this history,
Upgrade Guide BES12. Version 12.1
Upgrade Guide BES12 Version 12.1 Published: 2015-02-25 SWD-20150413111718083 Contents Supported upgrade environments...4 Upgrading from BES12 version 12.0 to BES12 version 12.1...5 Preupgrade tasks...5
c360 Portal Installation Guide
c360 Portal Installation Guide Microsoft Dynamics CRM 2011 compatible c360 Solutions, Inc. www.c360.com [email protected] Table of Contents c360 Portal Installation Guide... 1 Table of Contents... 2 Overview
Reference and Troubleshooting: FTP, IIS, and Firewall Information
APPENDIXC Reference and Troubleshooting: FTP, IIS, and Firewall Information Although Cisco VXC Manager automatically installs and configures everything you need for use with respect to FTP, IIS, and the
Kaseya 2. Installation guide. Version 7.0. English
Kaseya 2 Kaseya Server Setup Installation guide Version 7.0 English September 4, 2014 Agreement The purchase and use of all Software and Services is subject to the Agreement as defined in Kaseya s Click-Accept
iw Document Manager Cabinet Converter User s Guide
iw Document Manager Cabinet Converter User s Guide Contents Contents.................................................................... 1 Abbreviations Used in This Guide................................................
ACTIVE DIRECTORY DEPLOYMENT
ACTIVE DIRECTORY DEPLOYMENT CASAS Technical Support 800.255.1036 2009 Comprehensive Adult Student Assessment Systems. All rights reserved. Version 031809 CONTENTS 1. INTRODUCTION... 1 1.1 LAN PREREQUISITES...
CentreWare for Microsoft Operations Manager. User Guide
CentreWare for Microsoft Operations Manager User Guide Copyright 2006 by Xerox Corporation. All rights reserved. Copyright protection claimed includes all forms and matters of copyright material and information
How To Use Gfi Mailarchiver On A Pc Or Macbook With Gfi Email From A Windows 7.5 (Windows 7) On A Microsoft Mail Server On A Gfi Server On An Ipod Or Gfi.Org (
GFI MailArchiver for Exchange 4 Manual By GFI Software http://www.gfi.com Email: [email protected] Information in this document is subject to change without notice. Companies, names, and data used in examples
4.0 SP2 (4.0.2.0) May 2015 702P03296. Xerox FreeFlow Core Installation Guide: Windows Server 2008 R2
4.0 SP2 (4.0.2.0) May 2015 702P03296 Installation Guide: Windows Server 2008 R2 2015 Xerox Corporation. All rights reserved. Xerox, Xerox and Design, and FreeFlow are trademarks of Xerox Corporation in
Microsoft Dynamics CRM Adapter for Microsoft Dynamics GP
Microsoft Dynamics Microsoft Dynamics CRM Adapter for Microsoft Dynamics GP May 2010 Find updates to this documentation at the following location. http://go.microsoft.com/fwlink/?linkid=162558&clcid=0x409
Installation Instruction STATISTICA Enterprise Server
Installation Instruction STATISTICA Enterprise Server Notes: ❶ The installation of STATISTICA Enterprise Server entails two parts: a) a server installation, and b) workstation installations on each of
Introduction. Configurations. Installation. Vault Manufacturing Server
Introduction Autodesk Vault Manufacturing (hence forth referred to as Vault Manufacturing) bridges the gap between tracking CAD design tools and ERP (Engineering Resource Procurement) systems with its
SQL 2014 Configuration Guide
SQL 2014 Configuration Guide 2015 ImproMed, LLC. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language
NSi Mobile Installation Guide. Version 6.2
NSi Mobile Installation Guide Version 6.2 Revision History Version Date 1.0 October 2, 2012 2.0 September 18, 2013 2 CONTENTS TABLE OF CONTENTS PREFACE... 5 Purpose of this Document... 5 Version Compatibility...
How do I set up a branch office VPN tunnel with the Management Server?
Fireware How To VPN How do I set up a branch office VPN tunnel with the Management Server? Introduction Using the WatchGuard Management Server, you can make fully authenticated and encrypted IPSec tunnels
LATITUDE Patient Management System
LATITUDE PACEART INTEGRATION 1.01 GUIDE LATITUDE Patient Management System LATITUDE PACEART INTEGRATION SYSTEM DIAGRAM a. Patient environment b. LATITUDE environment c. Clinic environment d. Data retrieval
Installing and Configuring vcloud Connector
Installing and Configuring vcloud Connector vcloud Connector 2.0.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new
Introduction and Overview
Inmagic Content Server Workgroup 10.00 Microsoft SQL Server 2005 Express Edition Installation Notes Introduction and Overview These installation notes are intended for the following scenarios: 1) New installations
ISSUE TRACK FOR WINDOWS INSTALLATION GUIDE VERSION 4.0.0.XX
ISSUE TRACK FOR WINDOWS INSTALLATION GUIDE VERSION 4.0.0.XX Contents CONTENTS Chapter 1 Introduction 1-1 Welcome to Issue Track for Windows 1-1 About this Guide 1-1 Product Name 1-1 Documentation Roadmap
Introduction 1-1 Installing FAS 500 Asset Accounting the First Time 2-1 Installing FAS 500 Asset Accounting: Upgrading from a Prior Version 3-1
Contents 1. Introduction 1-1 Supported Operating Environments................ 1-1 System Requirements............................. 1-2 Security Requirements........................ 1-3 Installing Server
How To Run A Pacemar Optima System On A Microsoft Powerbook 2.5 (Powerbook) With A Powerbook 1.5 And Powerbook 3.5 On A Pc Or Macbook 2 (Powerstation) With An
Paceart Optima System Technical Requirements This document details the hardware and software requirements for the Paceart Optima System. Performance of the Paceart System may be impacted if these requirements
BIGPOND ONLINE STORAGE USER GUIDE Issue 1.1.0-18 August 2005
BIGPOND ONLINE STORAGE USER GUIDE Issue 1.1.0-18 August 2005 PLEASE NOTE: The contents of this publication, and any associated documentation provided to you, must not be disclosed to any third party without
Installation Guide for Pulse on Windows Server 2012
MadCap Software Installation Guide for Pulse on Windows Server 2012 Pulse Copyright 2014 MadCap Software. All rights reserved. Information in this document is subject to change without notice. The software
Legal Notes. Regarding Trademarks. 2013 KYOCERA Document Solutions Inc.
Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held liable for any problems arising from
AutoMate BPA Server 10 Installation Guide
AutoMate BPA Server 10 Installation Guide AutoMate BPA Server follows the client/server model of computing where one or more servers are hosts that share their resources with multiple clients. Since data
How To Manage Storage With Novell Storage Manager 3.X For Active Directory
www.novell.com/documentation Installation Guide Novell Storage Manager 4.1 for Active Directory September 10, 2015 Legal Notices Condrey Corporation makes no representations or warranties with respect
ProSystem fx Document
ProSystem fx Document Server Upgrade from Version 3.7 to Version 3.8 1 This Document will guide you through the upgrade of Document Version 3.7 to Version 3.8. Do not attempt to upgrade from any other
Install MS SQL Server 2012 Express Edition
Install MS SQL Server 2012 Express Edition Sohodox now works with SQL Server Express Edition. Earlier versions of Sohodox created and used a MS Access based database for storing indexing data and other
Xerox EX Print Server, Powered by Fiery, for the Xerox 700 Digital Color Press. Printing from Windows
Xerox EX Print Server, Powered by Fiery, for the Xerox 700 Digital Color Press Printing from Windows 2008 Electronics for Imaging, Inc. The information in this publication is covered under Legal Notices
Installation Guide for Pulse on Windows Server 2008R2
MadCap Software Installation Guide for Pulse on Windows Server 2008R2 Pulse Copyright 2014 MadCap Software. All rights reserved. Information in this document is subject to change without notice. The software
Dell SupportAssist Version 2.0 for Dell OpenManage Essentials Quick Start Guide
Dell SupportAssist Version 2.0 for Dell OpenManage Essentials Quick Start Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.
Reconfiguring VMware vsphere Update Manager
Reconfiguring VMware vsphere Update Manager vsphere Update Manager 5.5 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a
DocumentsCorePack for MS CRM 2011 Implementation Guide
DocumentsCorePack for MS CRM 2011 Implementation Guide Version 5.0 Implementation Guide (How to install/uninstall) The content of this document is subject to change without notice. Microsoft and Microsoft
Features Reference. About Unified Communication System. Before Using This Machine. Starting a Meeting. What You Can Do During the Meeting
Features Reference About Unified Communication System Before Using This Machine Starting a Meeting What You Can Do During the Meeting Leaving a Meeting Managing Address Book Changing Network Configuration
NeuralStar Installation Guide
NeuralStar Installation Guide Version 9.8 Release 2 October 2011 1st Edition Preface Software License Agreement Software is defined as the Kratos Technology & Training Solutions, Inc. computer programs
IBM Sterling Control Center
IBM Sterling Control Center System Administration Guide Version 5.3 This edition applies to the 5.3 Version of IBM Sterling Control Center and to all subsequent releases and modifications until otherwise
MicrosoftDynam ics GP 2015. TenantServices Installation and Adm inistration Guide
MicrosoftDynam ics GP 2015 TenantServices Installation and Adm inistration Guide Copyright Copyright 2014 Microsoft Corporation. All rights reserved. Limitation of liability This document is provided as-is.
USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6
KRAMER ELECTRONICS LTD. USER GUIDE Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6 Contents 1 Connecting to the Kramer Device via the Ethernet Port 1 1.1 Connecting the Ethernet Port Directly
MultiSite Manager. Setup Guide
MultiSite Manager Setup Guide Contents 1. Introduction... 2 How MultiSite Manager works... 2 How MultiSite Manager is implemented... 2 2. MultiSite Manager requirements... 3 Operating System requirements...
4.0 SP1 (4.0.1.0) November 2014 702P03296. Xerox FreeFlow Core Installation Guide: Windows Server 2008 R2
4.0 SP1 (4.0.1.0) November 2014 702P03296 Installation Guide: Windows Server 2008 R2 2014 Xerox Corporation. All rights reserved. Xerox, Xerox and Design, FreeFlow, and VIPP are trademarks of Xerox Corporation
Aspera Connect User Guide
Aspera Connect User Guide Windows XP/2003/Vista/2008/7 Browser: Firefox 2+, IE 6+ Version 2.3.1 Chapter 1 Chapter 2 Introduction Setting Up 2.1 Installation 2.2 Configure the Network Environment 2.3 Connect
Microsoft Dynamics GP. Engineering Data Management Integration Administrator s Guide
Microsoft Dynamics GP Engineering Data Management Integration Administrator s Guide Copyright Copyright 2007 Microsoft Corporation. All rights reserved. Complying with all applicable copyright laws is
Omgeo OASYS Workstation Installation Guide. Version 6.4 December 13, 2011
Omgeo OASYS Workstation Installation Guide Version 6.4 December 13, 2011 Copyright 2011 Omgeo LLC. All rights reserved. This publication (including, without limitation, any text, image, logo, compilation,
TIGERPAW EXCHANGE INTEGRATOR SETUP GUIDE V3.6.0 August 26, 2015
TIGERPAW EXCHANGE INTEGRATOR SETUP GUIDE V3.6.0 August 26, 2015 2201 Thurston Circle Bellevue, NE 68005 www.tigerpawsoftware.com Contents Tigerpaw Exchange Integrator Setup Guide v3.6.0... 1 Contents...
SQL Server 2008 R2 Express Edition Installation Guide
Hardware, Software & System Requirements for SQL Server 2008 R2 Express Edition To get the overview of SQL Server 2008 R2 Express Edition, click here. Please refer links given below for all the details
Human Resources Installation Guide
Human Resources Installation Guide Installing HR i Index Copyright 2001 Jenzabar, Inc. You may print any part or the whole of this documentation to support installations of Jenzabar software. Where the
MadCap Software. Upgrading Guide. Pulse
MadCap Software Upgrading Guide Pulse Copyright 2014 MadCap Software. All rights reserved. Information in this document is subject to change without notice. The software described in this document is furnished
Sophos for Microsoft SharePoint startup guide
Sophos for Microsoft SharePoint startup guide Product version: 2.0 Document date: March 2011 Contents 1 About this guide...3 2 About Sophos for Microsoft SharePoint...3 3 System requirements...3 4 Planning
Fiery EX4112/4127. Printing from Windows
Fiery EX4112/4127 Printing from Windows 2008 Electronics for Imaging, Inc. The information in this publication is covered under Legal Notices for this product. 45083884 01 April 2009 CONTENTS 3 CONTENTS
Oracle Enterprise Manager. Description. Versions Supported
Oracle Enterprise Manager System Monitoring Plug-in Installation Guide for Microsoft SQL Server Release 12 (4.1.3.2.0) E18740-01 November 2010 This document provides a brief description about the Oracle
EntroWatch - Software Installation Troubleshooting Guide
EntroWatch - Software Installation Troubleshooting Guide ENTROWATCH SOFTWARE INSTALLATION TROUBLESHOOTING GUIDE INTRODUCTION This guide is intended for users who have attempted to install the EntroWatch
NETWRIX EVENT LOG MANAGER
NETWRIX EVENT LOG MANAGER ADMINISTRATOR S GUIDE Product Version: 4.0 July/2012. Legal Notice The information in this publication is furnished for information use only, and does not constitute a commitment
Install Pocket Inventory in a Windows Server 2003 R2 Standard Environment
One Blue Hill Plaza, 16th Floor, PO Box 1546 Pearl River, NY 10965 1-800-PC-AMERICA, 1-800-722-6374 (Voice) 845-920-0800 (Fax) 845-920-0880 Install Pocket Inventory in a Windows Server 2003 R2 Standard
STATISTICA VERSION 9 STATISTICA ENTERPRISE INSTALLATION INSTRUCTIONS FOR USE WITH TERMINAL SERVER
Notes: STATISTICA VERSION 9 STATISTICA ENTERPRISE INSTALLATION INSTRUCTIONS FOR USE WITH TERMINAL SERVER 1. These instructions focus on installation on Windows Terminal Server (WTS), but are applicable