Information. Cleanroom Product Range-subjected to change
|
|
|
- Alvin Marshall
- 9 years ago
- Views:
Transcription
1 Cleanroom Product Range-subjected to change 123
2 General information Introduction to Cleanroom The term Cleanroom is something you associate with in modern industries. However, the root of cleanroom design goes back more than a century. Think of the need to control contamination in hospitals and you would be able to imagine the first cleanroom. It can be seen that the requirement for cleanroom can be broadly divided into two areas: That in which inanimate particles are a problem and where their presence may prevent a product functioning or reduce its useful life. To ensure the absence of microbe carrying particles whose growth could lead to human infection. Definition of cleanroom It is clear that a cleanroom is a room that is clean. However, a cleanroom now has a special meaning and it is defined in ISO as: A room in which the concentration of airborne particles is controlled and which contains one or more clean zones. And in ISO as: A room in which the concentration of airborne particles is controlled, and which is constructed and used in a manner to minimise the introduction, generation and retention of particles inside the room and in which other relevant particles inside the room and in which other relevant parameters e.g. temperature, humidity and pressure, are controlled as necessary. Classification of cleanroom Cleanroom are classified by the cleanliness of their air. The method most easily understood and universally applied is the one suggested in versions of Federal Standard 209 up to edition "D. The Federal Standard FS 209D Table shows the simplified classification of Cleanroom Class according to the older Federal Standard 209D. This standard has now been superseded by the metric version; Federal Standard 209E which was published in The basic unit of measurement within a cleanroom is a micron (µm) which is one millionth of a metre. To classify cleanroom, the number of particles equal to and greater than 0.5 µm is measured in one cubic foot of air and this count is used to identify the Cleanroom Class. However, because of the simplicity and universal usage of the Federal Standard 209D, it is unlikely to be forgotten or removed. It is also likely that the Federal Standard 209E will supersede it but by the new International Standard Organisation s (ISO) standard ISO Cleanroom for different industries The required standard of cleanliness of a room is dependent on the task performed in it; the more susceptible the product is to contamination, the better the standard. How small is a sub micro particle? Objects Human hair 100 Rubbing or abrading an ordinary painted surface 90 Sliding metal surfaces (non-lubricated) 75 Crumpling or folding paper 65 Rubbing an epoxy painted surface 40 Belt drive (Conveyor) 30 Dust 25 Writing with ball pen on ordinary paper 20 Abrading of the skin 04 Oil smoke particles 0.1 The Federal Standard FS 209D Class Measured Particle Size [µm] The possible cleanroom requirements for various tasks Approximate Size [µm] NA NA 100 NA NA 1000 NA NA NA NA NA NA NA NA NA ISO Class (FS 209E) ISO Class 3 (Class 1) ISO Class 4 (Class 10) ISO Class 5 (Class 100) ISO Class 6 (Class 1000) Tasks Integrated circuit manufacturers manufacturing sub-micron geometries only use these rooms. Semiconductor manufacturers producing integrated circuits with line widths below 2 µm use these rooms. Used with a bacteria-free or particulate-free environment is required in the manufacture of aseptically produced injectable medicines. Required for implant or transplant surgical operations. Manufacture of high quality optical equipment. Assembly and testing of precision gyroscopes. Assembly and testing of precision gyroscopes. Assembly of miniaturised bearings. ISO Class 7 (Class 10000) ISO Class 8 Class ) Assembly of precision of hydraulic or pneumatic equipment, servo-control valves, precision timing devices, high grade gearing. General optical work, assembly of electronic components, hydraulic and pneumatic assembly. 124 Cleanroom Product Range-subjected to change
3 General information International standard of cleanroom Introduction The Federal Standard 209E have long been the only definition of cleanroom classification available from a standard organisation. It is from the U.S. General Service Administration and approved for use by all U.S. Agencies. In the absence of an international standard, FS 209E was broadly used internationally. The need for a new international standard that covered more cleanroom environmental parameters and practices led to the formation of a technical committee of the International Standards Organisation. The technical committee is named TC 209 Cleanroom and Associated Controlled Environments. The goal of TC 209 is standardization of equipment, facilities and operational methods for cleanroom and associated controlled environments. This includes procedural limits and testing procedures to achieve desired attributes to minimise micro contamination. The ISO committee will produce 11 new standards documents that relate to cleanroom or clean zones. Cleanroom standard adopted by different countries Some countries completely adopted FS 209, while others made their own national version, similar to FS 209. Some made minor changes of the classes to comply with the metric system, but all changed the denomination of the classes. Because of the different naming of the classes in different countries, care must be taken not to mix up the standards. Some major national standards exist today: British standard: BS5295 Japanese standard: JIS B 9920 Australian standard: AS 1386 French standard: AFNOR X Dutch standard: VCCN-RL-1 Russian standard: GOST R The table shows major national standards exist today. Germany standard: VDI2083 The German Engineering Association, known as VDI, has published the VDI 2083 as "Cleanroom engineering" guideline, for the first time in The various tasks and measures associated with cleanroom technology are described the VDI guideline series VDI This guideline, which was Country Standard Year Description developed just recently, is the only guideline, which can be used for the classification of operating materials. The aim of this guideline is to provide a standardized procedure for qualifying or comparing operating materials with regards to their airborne particle emission. FESTO is applying this guideline for the particle emission tests it conducts. Australia AS Cleanroom and clean work stations France AFNOR X Definition of cleanroom levels Germany VDI Contamination control measuring technique for clean air rooms Holland VCCN Dust and micro-organism classification of air Japan JIS-B Measuring methods for airborne particles in cleanroom and evaluating methods, etc. Russia Gost-R Cleanroom classification, General requirements UK BS Environmental cleanliness in enclosed spaces US FS 209E 1992 A comparison of major engineering cleanroom classes in the world USA 209E 1992 ISO ISO Class 1 1 Japan B France X ISO Class Airborne particulate cleanliness classes in cleanroom and clean zones Germany VDI UK BS Australia AS ISO Class C ISO Class D ISO Class E,F ISO Class G,H ISO Class J ISO Class K 3500 ISO Class 9 7 L Cleanroom Product Range-subjected to change 125
4 General information International standard for cleanroom Introduction After 40 years, the FS 209E has been officially retired. This paves the way for worldwide harmonisation promised by the new cleanroom protocols from the International Organisation for Standardisation (ISO). The Institute of Environmental Sciences and Technology (IEST) submitted a request to retire the federal standard and it was approved. The Federal Standard 209E was officially retired by the US Government on 29 November Basically, the quality of air in a cleanroom has not changed, what has changed is the measuring system. ISO standards use only the metric system. Almost all countries now use the new ISO standard. ISO classification standard Because of the large number of cleanroom standards produced by individual countries, it is very desirable that one worldwide standard of cleanroom classification is produced. ISO has set up a technical committee (TC 209) and will produce 10 new standards documents that relate to cleanroom or clean zones. The first two standards have been published: ISO and 2. ISO classification of air cleanliness Cleanliness class designations and quantity have changed from FS 209E. Along with the obvious change to metric measure of air volume, ISO adds three additional classes two cleaner than Class 10 and one dirtier than Class 100,000. ISO cleanroom testing for compliance ISO determines the type and frequency of testing required conforming to the standard. Table 2.12 indicates which tests are mandatory and Table 2.13 indicates which tests are optional. Summary of FS 209E and ISO and 2 The cleanliness classification levels defined by FS 209E and ISO are approximately equal, except the new ISO standard uses new class designations, a metric measure of air volume and adds three additional classes two cleaner than Class 10 and one dirtier than Class 100,000. The second new ISO standard, ISO , gives requirements for monitoring a cleanroom or clean zone to provide evidence of its continued compliance ISO Airborne Particulate Cleanliness Classes ISO Class ISO Number of Particles per Cubic Meter by Micrometer Size 0.1 µm 0.2 µm 0.3 µm 0.5 µm 1 µm 5 µm ISO ISO ISO ISO ISO ISO ISO ISO ISO Schedule of Tests to Demonstrate Continuing Compliance Test Parameter Class Particle Count Test Air Pressure Test Table compares the FS 209E to the new ISO classifications. Maximum Time Interval Test Procedure ISO 5 6 months ISO Annex A ISO 5 12 months All Classes 12 months ISO Annex B5 Air Flow All Classes 12 months ISO Annex B4 ISO ISO Class FED STD 209E English Metric M M M M M M Cleanroom Product Range-subjected to change
5 General Information Basic principles for designing cleanroom equipment Introduction The design of cleanroom equipment plays an important role in cleanroom technology. It would be wasteful to design a state-of-the-art cleanroom and do not place any importance on the equipment used in the cleanroom. When designing cleanroom equipment, care must be taken right from the initial stage. Using pneumatic cylinder in cleanroom When you lower the piston speed, the particle count will greatly reduce as the impact at the end position is reduced. To help reduce the impact, cylinders with cushioning will significantly help in the reduction of particles generated. When there is a need to have end position stopping, do not use rubber stoppers, use shock absorbers as they generate lesser particles. Using rotary moving elements Whenever possible rotary movements should be employed, as lesser particles are generated by rotary moving elements. Furthermore, it is easier to seal rotating elements from the clean environment. Minimising sliding friction The design should minimise sliding friction. Do not use sliding tracks, it is better if you could use roller tracking. Lip sealing is also not allowed and tries to avoid unnecessary functional contact. Principle of arranging task integration Reduce the number of components used to a minimum, if possible make use of single components which can assume several functions. Analysing ways of gripping products If you need to use a gripper in the production, avoid gripping in the same direction as the direction of the first airflow. Keep the product contact to a minimum either by the equipment or the operator. If you grip either from the side or from beneath the product, the gripper does not affect the airflow around the product and the airflow obstruction caused by the gripper is kept to a minimum. If the gripper can only be used above the product, then keep moving elements next to the product and select the shape of the gripper and its distance away from the product in such a way that stagnant areas do not reach the product Choice of materials / surface finish With regard to the choice of materials, the following are recommended: Use materials with low electrostatic charge properties Combination of materials: plastic - metal: avoid insulated partial systems Surfaces should be smooth where possible, no sharp edges Easier to clean, minimising influence on airflow In semiconductor industry: No moving elements made of copper of brass Better: special steel, aluminium Secondary measures and alternatives The following are some additional guidelines, which should be considered: Encapsulating components All moving parts enclosed Vacuum Suction Accurately aimed local airflow direction Unconventional sources of contamination In addition to dust and other particles, surface contamination can be any one of the following reaction layers of chemical compounds, absorbed layers of mostly hydrocarbons and moisture, or variable composition contaminants due to preferential diffusion of one component through a substrate. ESD behavior of operating materials ESD stands for Electrostatic Discharge. It is the rapid transfer from static charged bodies of materials to or from Electrostatic Discharge Sensitive Electronic Devices. Virtually all electronic devices are ESD sensitive; the sensitivity is based on product and design. ESD occurs when charge is generated, stored on an object and rapidly transferred. Materials become charged via: First air flowing onto them Friction from other materials Particles generated are not removed by the first air flow Contamination adheres to charged materials Formation of larger agglomerates Sporadic, intermittent detachment of very large forms of contamination ESD is harmful to the system and must be removed. Recommended ways of removing of electrostatic charges are: Magnetic influences When handling components, which are subject to magnetic influences, care must be taken to ensure that they are shielded from the electromagnetic effects. Another option would be keeping critical products away from Electric motors, permanent magnets, coils and electromagnetic fields. Properties of materials The properties of the materials used in the equipment affects the level of contamination. If the wrong choice were made there would be more particles emitted and would greatly affect the cleanroom. Take note of the following points when choosing the right material: Know the emission of particles from the material in use Constantly Sporadically Which size of particle, critical/ uncritical? Which combinations of materials emit particles Know the life span of material Correlation between the wear and tear of materials used and tool life Outgassing When the equipment is under extremes of temperature, there is the likely occurrence of "Outgassing" which is simply the release of gases or volatile substances from a material other than a change of state of the material. Make sure that the emission levels of volatile substances do not exceed limits. They must not be harmful to either the product or the personnel working the area. The materials chosen must pass tests at extremes of temperature. Cleanroom Product Range-subjected to change 127
6 General Information Qualifying equipment for cleanroom used Qualification tests are carried out to assess the cleanroom suitability of operating materials that include equipment. It is very important to note here that No operating material may be allocated to a cleanroom class. It is therefore wrong to say that Our product has the Cleanroom ISO Class 3 The reasons are: Cleanroom classes were drawn up only for the acceptance and classification of cleanroom. Operating materials do not fulfil these fundamental conditions. Missing of specifications for the classification of operating materials. Correlation of cleanroom classification / air volume Air volume Defined degree of cleanliness per volume of air Procedures for classification standards are related to cleanroom Moreover we could not just transfer the cleanroom classifications to operating materials, because these are standards based on degree of cleanliness per volume of air and not for qualifying equipment used in the cleanroom. It is important to note that the Federal Standard and ISO standard does not cover this area. VDI 2083 Part 8 "Cleanroom suitability of equipment", which was developed just recently, is the only guideline, which can be used for the classification of operating materials. This guideline is applicable to operating materials which are introduced into a cleanroom. The aim of this guideline is to provide a standardized procedure for qualifying or comparing operating materials with regards to their airborne particle emission. FESTO is applying this guideline for the particle emission tests it conducts on all Festo cleanroom products. Introduction of VDI2083 Part 8 Operating materials are often responsible for contaminating the production environment in cleanroom. An operating material does not process a cleanliness class, rather only a suitability for use in cleanroom classes. This means that an operating material may only be assessed with respect to its use in cleanroom with a defined level of particle cleanliness of the air. The design, construction and operation of an operating material (geometry and dynamics) should be selected in such a way that airflow patterns in the cleanroom environment are affected as little as possible. This can also checked by performing airflow visualization tests. The standardized assessment of airborne particle emission, supported by a statistical analysis of the results, should enable a comparison and assessment of operating materials. This should lend transparency to the assessment of operating materials concerning their suitability for use in cleanroom. Cleanroom suitability Cleanroom suitability assesses the suitability of an operating material for use in cleanroom which have been specified in accordance with a regulating body for assessing air cleanliness. The classification criterion in this instance is the emission of particles from the operating material. Measurement technology Only optical particle counters (OPC) have been used in this guideline for measuring airborne particles. Further information concerning the use, handling and method of function of OPC s can be found in the guidelines VDI 3489 Part 3 and VDI 2083 Part 3. Procedure The highest concentration of particulate contamination emitted from the operating material into the system or product space is measured. The size distribution of particles emitted from the operating material being assessed for its cleanroom suitability may vary considerably. As the distribution characteristics of each operating material are not always known, it does not suffice to investigate only one range of particle size. Therefore, at least three representative particle size ranges are to be selected. These must be as distant from one another as possible. The concentration measured is then compared with the limiting values given by the regulating body concerned with air cleanliness and thus an assessment made of suitability for use in a specific air cleanliness class defined by that regulating body. The procedure for carrying out cleanroom suitability tests in accordance with regulating bodies for assessing air cleanliness may be summarized as follows: Specification of operating parameters; Localization of particle sources; Classification measurements; Statistical analysis; Classification of the operating material Measurement classification The parameters required for the classification measurements are either prescribed or have been ascertained from the measurements taken beforehand: Typical operating conditions of the operating material during the measurement procedure; Measuring points on the operating material; Positions of the OPC sampling probe at the operating material measuring points. Statistical analysis The suitability of an operating material for a given cleanroom class is determined using a statistical method. For this, all particle size ranges measured must be taken into consideration. In order to obtain significant data for all the statistical observations to be carried out, there must be a random distribution of particles in the air. 128 Cleanroom Product Range-subjected to change
7 General Information Measurement of airborne particle in cleanroom One of the major sources of contamination is operating materials. Contamination caused by operating materials can be either: Chemical Physical Biological Radiological Ionic Particle contamination falls under the umbrella of physical contamination. Particles is caused by: When leakage from the pneumatic components will lead to particle contamination. The air, which leaks, might bring along particles with it. When operating materials come into contact with one another, there is bound to be abrasion, make sure that the abrasion is to a minimum as particles are generated. When the pneumatic components move from end to end, there tend to be knocking at the end position, this will lead to minor vibration and also cause particles to be released. The optical particle counter OPC It is a microprocessor-based instrument that detects airborne particles, analyses and stores the data in eight size classes, and produces reports. It displays real time data on a CRT and contains a printer, which can be used to produce hard copies of reports. Measuring the test environment In order to get correct particle count results, the test environment, in which the tests are carried out should have little or no influence on the particle measurements. The parameters, which influence the particle count, are the particle count in the: Environment Air velocity Degree of turbulence Relative humidity The purpose of measuring the test environment is to determine whether the given environment is suitable for particle measurement. Therefore, the ground contamination level of the test environment has to be measured for the cleanroom as well as the Mini-environment (MENV). The lower the "ground contamination level", the more accurate the particle measurements will be. Zero the count measurement Before any test is done, a zerocount measurement is made. When doing a zero-count measurement, it is a functional test. For this test, a zero-filter is attached to the OPC and the counter takes measurement for about 3 minutes. The reading obtained should be zero. Then the environment is ready for use. Base Measurement of Airborne Particulate in MENV Similar to the zero-count measurement, which is used for the OPC, the base measurement is used for the Mini-environment. VTH Measurement Three major environment parameters: Air velocity (V) Air Temperature (T) Relative Humidity (H) are measured in the cleanroom and MENV to ensure the meet the requirements. We obtain these readings by using the Kanomax Climomaster. This is a precision measuring instrument, which has velocity, temperature and humidity sensors. Simultaneous measurements of air velocity air temperature and relative humidity can be obtained with a single probe of this instrument. The measurement time is 3 minutes, 1.0 ft³ and at maximum airflow velocity of the MENV. The measurement point used is the center of MENV on operational level of component. The Climomaster is setup as follows: Data sampling time : 60 seconds Data sampling interval : 1 second Number of sampling data : 1 VTH measurement time : 3 minutes Upon completion of the test, the readings must be within the parameters: First airflow velocity : 0.45 ± 0.05 m/s Temperature : 20.0 ± 2.0 C Relative humidity : 55 ± 10% During the airborne particle emission measurements, the operating parameters of the optical particle counter are set as follows: Air volume : 1.0 cfm Sampling time : 60 seconds Delay time : 1 second Measurement time : 5 minutes Cleanroom Product Range-subjected to change 129
8 General Information The principle of measuring contamination level of pneumatic components The Direct Measurement Principle The Average Measurement Principle Introduction Basically there are two different measuring principles how to assess the clean room suitability of operating materials. One principle is to localize the particle source and to measure the particle emission directly at its source. Another principle is to assess the total particle emission, by measuring the average particle emission in the space surrounding the operating material. The direct Measurement Principle Applying the direct measurement the specimen is operated inside a clean room or mini environment. There should be laminar, vertical air flow around the specimen. While the specimen is operated a particle counter with a movable measurement probe is used to screen the entire product for sources of particles. Subsequently, the particle emission is measured for 100 minutes at every particle source, which has been located before, in order to establish the particle emission behavior. The major advantage of this principle is that it can be applied to operating equipment of almost any size. Furthermore, it provides some information about the particle distribution and concentration around the operating material. This measurement principle is described in detail in the VDI guideline. The average Measurement Principle Using the average measurement principle, the specimen is operated inside a container. The container is then supplied with a defined volume of clean dry air. Simultaneously, the particle emission is measured inside the container, by using an optical particle counter. All air, which does not flow through the particle counter, is release through an exhaust opening. In order to get the measurement results, the ration between the exhaust air and the amount of air flowing through the particle counter has to be known. The major disadvantages of this method are that the result largely depends on the placement of the measurement probe inside the container as the particle emission is not necessarily consistent. This makes the measurement principle also very unsuitable for measuring larger operating materials, as the particle emission get more inconsistent inside of larger containers. The advantage of this method is that it allows a direct comparison among several test specimen. Furthermore, it is a lot easier to handle. There is no guideline available from any independent organization, such as ISO, VDI, DIN, FDA etc., describing this measurement principle. How does FESTO measure? FESTO decided to apply the direct measurement method, as this measurement allows the user to gain information about the highest particle concentration around the product. Furthermore, this measurement method is described in the VDI guideline, which gives FESTO the possibility to have a neutral reference for the measurements. 130 Cleanroom Product Range-subjected to change
9 Festo Cleanroom project Festo cleanroom project - A collaboration among 3 parties Festo s cooperation with Fraunhofer of Germany and Nanyang Polytechnic of Singapore The cleanroom environment in Nanyang Polytechnic of Singapore Supply Air from Fans Return Air Window Panel HEPA Ceiling Utility and Equipment Chase Return Air Plenum Floor Grey Room Cleanroom The cleanroom project initiated by Festo is a collaboration among Fraunhofer Institute for Manufacturing Engineering and Automation in Germany, Nanyang Polytechnic (NYP) of Singapore and Festo Singapore. The objective is to work together in the field of particle emission of Festo products. Furthermore, it is Festo s intention to improve the experience in the field of particle measurements, contamination control as well as cleanroom applications in general. We re doing the measurement according the VDI guideline which is described on page 82 and the following pages. Fraunhofer Institute approved this measurement principle and attested this in a Certificate of qualification. The certification covers: The support for the performance of testing the cleanroom suitability of pneumatic components of the company Festo AG & Co. Cleanroom environment The cleanroom environment in Nanyang Polytechnic is ISO Class 6 cleanroom. The design of this cleanroom is shown. This is a cleanroom typical layout. This is a ballroom type cleanroom with the area of 120 m 2. The air flows in a unidirectional way from a ceiling of High Efficiency Particular Air (HEPA) filters down to the floor of the cleanroom. The return air passes through a return air plenum in the Grey Room. The Grey Room, which is located just beside the cleanroom, where it is used for service. Cleanroom Product Range-subjected to change 131
10 Festo Cleanroom project Test procedure of Festo cleanroom components Mini-environment (MENV) A Class 1 clean Mini-Environment (MENV) is used within a cleanroom to provide the high level of protection to products against contamination and ESD events. The specification of MENV is shown. This MENV is a cleanroom test cabinet with one clear antistatic front panel and three side panels. The dimension of MENV is 1.2m x 0.6m internal area and with 2.2m height. In order to achieve high cleanliness class, Ultra Low Penetration Air (ULPA) Fan Filter Unit ( % efficiency on 0.12 micron) is installed on the ceiling of the MENV. The unidirectional supply of air flows vertically from the Fan Filter Unit (FFU), and the air velocity can be adjusted up from 0.2 m/s to 0.6 m/s. In accordance with the US FED- STD-209E, a cleanroom is classified to be of Class 1 if only one particle of the size of 0.5 µm or larger can be found in a reference volume of one cubic foot of the first air (filtered air supplied). In accordance with the ISO , a cleanroom is classified to be of Class 3 if only 35 particles of the size of 0.5 µm or larger can be found in a reference volume of one cubic meter of the first air (filtered air supplied). There is no tabletop installed in the mini environment. Instead a removable clean room trolley with perforated tabletop is used. The height of the trolley/ table is approx m Summary specification of MENV Design: Internal Dimensions: Cleanliness: Air Velocity: Light Intensity: Main Body: Front Design: Power Supply: Vertical Laminar Flow 1200 x 600 mm ISO Class m/s infinitely adjustable lux Aluminium Clear Front Cover 230 V, single phase 50 Hz Optical Particle Counter The LASAIR 210 OPC is used to detect the concentration of particles. The flow volume of this counter is 1.0 CFM (cubic foot per minute) or 28.3 liters per minute. The counter is able to detect particle size from 0.2 µm to 5.0 µm. The particle counter has eight channels. The setting of OPC is: Data Sampling Time: 60 seconds Data Sampling Interval: 1 second Measurement Time: 120 minutes Measuring Instrument The two most important test instruments for the particle measurements are Optical Particle Counter (OPC) and Flow Meter. A LASAIR 210 Optical Particle Counter, manufactured by Particle Measuring Systems Incorporation, and Model 6521 Climomaster (airflow, relative humidity and temperature measurement), manufactured by KANOMAX Japan incorporation, are used in the particle measurements. Flow Meter The flow meter Model 6521 Climomaster is used to measure the airflow parameters. Simultaneous measurements of air velocity, air temperature and relative humidity can be obtained with a single probe of this precision instrument. The setting of flow meter is Data Sampling Time: 60 seconds Data Sampling Interval: 1 second Number of Sampling Data: 1 Measurement Time: 3 minutes 132 Cleanroom Product Range-subjected to change
11 Festo Cleanroom project Test procedure of Festo cleanroom components Testing of Festo cleanroom pneumatic product range The VDI guideline describes, how particle measurements have to be carried out, in order to establish the particle emission of individual equipment. If a whole range of equipment is to be tested, it becomes viable to define, whether all types and sizes of the equipment has to be tested or whether it would be sufficient to test a defined share and to apply the results to the remaining products. Such a procedure becomes especially important if extensive product ranges are involved. To achieve the above mentioned, this guideline has been developed. The guideline is based on the measurement procedures applied by F-SG. This guideline is not a FESTO Standard. Subject of test FESTO products, which are part of the clean room product range. It does not apply to the testing of standard product or special applications. Specimen Selection The number of specimen to be tested is determined by the size and the number of products in one product range. In every product range, the smallest and the largest type is tested. The terms small and large are defined as follows: For cylinders, slide units, shock absorbers and grippers, small and large are defined by the piston diameter. For valves and filters, service units, small and large are defined by the flow rate. For tubes and fittings, small and large are defined by the tube diameter. Furthermore, at least, 25% of all products within one product range have to be tested. Each test is conducted with a number of two identical specimens. Definition of a Product Range The selection of test samples does apply only, if the product design is consistently the same, throughout a product range. This is defined as follows: The working principle of all products within the product range is identical. All materials of all products within the product range are identical, including all lubricants. The geometry of all products within the product range is identical, especially the geometry of all seals. The working pressure of all products within the product range is the same. If not all products of a product range fulfill the abovementioned requirement, all products of that particular product range have to be tested. Cleanroom Product Range-subjected to change 133
12 Festo Cleanroom project Test procedure of Festo cleanroom components Standard operation procedure (SOP) are done before actual commencement of the test. These procedure are standard regardless of the type of test specimen. Step 1: Inward transfer of test samples Before any test is done, the components need to be prepared. The preparation for the cleanroom suitability assessment involves the cleaning of these components according to the Festo-SG guidelines "Operating Conditions for Cleanroom Tests". The cleaning sequence is outlined below: Decontamination of test samples (inner and outer parts) with Isopropanol saturated wipers and ultrapure compressed dry air. Sequence: Pre-cleaning by blowing component surface with ultra-pure compressed dry air. Cleaning of component surface using pre-saturated wipers containing a blend of Isopropyl alcohol. Final cleaning by blowing component surface with ultra-pure compressed dry air. Bringing the test samples into the CR-environment and MENV Arranging the test samples (with gloves, intermediate decontamination, cleaning) Step 2: Testing of instrument It is also important to note that each time before the tests are made the required zero count measurement, base measurement and VTH measurement are carried out as follows: OPC airflow OPC laser-reference OPC zero-particle-count (measurement time: 3 minutes, with zero-filter attached) MENV air flow velocity (maximum power of FFU) Relative humidity (measurement time: 1 minute with measurement intervals of 1 second) Airflow-velocity (measurement time: 1 minute with measurement intervals of 1 second) Temperature (measurement time: 1 minute with measurement intervals of 1 second) Base measurements of MENV, airborne particulate contamination (measurement time 3 minutes, 1.0 cft, at maximum air flow velocity of MENV, measurement point in the center of MENV on operational level of component) Step 3: Adjustment of the operating parameters for the test sample After mounting the component on a test support fixture, it is ready for the test. Adjustment of operating parameters e.g. cushioning on actuator, speed of actuator Statement about performed duty cycles at the time of testing Documentation of adjustment (sketch or photograph) Step 4: Localization measurements Determination of points of highest concentrations of particle emission (according to VDI 2083 part 8) Coarse localization measurement Localization measurement Step 5: Classification measurements During the test, the airborne particle generated by the component is measured using a discrete particle counter (DPC). Particle size is 0.2 mm, 0.7 mm, 1.0 mm, 2.0 mm, 3.0 mm, and 5.0 mm are selected. Measurement time: standard-classification: 100 minutes (according to VDI 2083 part 8) at the measurement points that were found during the Localization measurements lifecycle-test: several days, up to months Documentation of measurements points (sketch or photograph) Step 6: Statistical evaluation Evaluation according to guideline VDI 2083 part 8 Step 7: Visual inspection Visual inspection of tested components (e.g. wear and tear, deposition of lubricants and particles, product failure ) Step 8: Classification Classification of test specimen according to statistical evaluation and visual inspection (see guideline VDI 2083 part 8) 134 Cleanroom Product Range-subjected to change
13 Festo Cleanroom project Test procedure of Festo cleanroom components Step 9: Documentation Complete documentation should contain the following information Title, Date, Place of test Person responsible Test environment Operating Parameters Temperature Relative humidity Air flow velocity Particulate concentration in test environment Measurement technology Type Model Detection limits Air flow Description of sample technique Sample Characteristics Type Supplier Serial Number Component description Operating parameters of components Break-in load Running-in time Mounting position Operating frequency Attached load Supply (air- power supply etc.) Description of measurement points Sketches or photographs References to applied standards and guidelines Documentation Particle concentration at measurement points Graphical visualization of particle emission Interpretation of results and conclusion Classification related to applied standards/ guidelines General Assessment Potential for optimization Operating condition for testing Festo components in cleanroom Operating Conditions are defined by Festo-SG individually for different Festo products. The guidelines for product range, cylinders, rotary actuators, valves, grippers and service units are listed in page 88 and 89. Preparing compressed air for testing Festo components in cleanroom Compressor Air storage Refrigeration dryer Prefilter regulator of 40 µm Fine filter 1 µm Micro filter 0.1 µm Testing of DSNU- -RR-SA cylinder Testing of ADVU- -RR-SA cylinder Testing of CDN- -RR-SA cylinder 1 2 Air 40 µm 1µm 0.1 µm Cleanroom Product Range-subjected to change 135
14 Festo Cleanroom project Conditions at which Festo cleanroom components are tested Operating conditions for Cleanroom tests - Cylinders Pneumatic linear actuators: Single- and double-acting cylinders with and without piston rods Guide and slide units Each test is conducted with a number of two identical specimens. The supply air should be clean dry air. This clean dry air is filtered with micro-filter which eliminates % of particles bigger than 0.01 mm. The operating pressure for all samples is 6.0 ± 0.3 bar or maximum pressure, for specimen, whose operating pressure is less than 6.0 bar. The ambient temperature should be 20 ± 2 C. The medium temperature should not exceed 30 C. The max. speed is defined as 0.2 m/s for all kinds of cylinders. The speed is adjusted by means of one-way flow control valves, installed as close as possible to the cylinder ports. The adjustment is done in a way, that the piston safely reaches its end-position. Tables below shows: A pulse/ interval ratio of 1:1 should be used for all frequencies. On the condition of the max. speed 0.2m/s, the different frequencies are defined due to different piston diameter., they are shown as following table. The frequencies can be adjusted by changing PLC programming. Type Piston rod cylinder Rodless cylinders Piston diameter [mm] 6 to to to to to Frequency [Hz] The end position cushioning should be adjusted in such a way that there is no hard metallic impact in the end positions and the piston does not rebound. For test sample of cylinders, the following stroke lengths are chosen for the various piston rods as: Piston diameter [mm] Stroke length * [mm] 6 to 8 20 or max. stroke 10 to or max. stroke 25 to or max. stroke 40 to or max. stroke 63 to or max. stroke Cleanroom test of cylinders should be carried out under different load conditions. However, because of short of time, cylinders are only tested under the condition of horizontally mounted with a load. Table below shows: Load parameters for piston-rod cylinders without guide or protection against torsion. Ø [mm] Additional Mass [kg] (3% theoretical effective force) In the case of cylinders with protection against torsion, testing should be carried out using 20% of the maximum moment. Piston Diameter [mm] Suction rate at vacuum port Ø [mm] Min. vacuum flowrate [l/min] Moment due to additional load [Nm] M = m x g x s Additional Mass [kg] (20% theor. effective force) Recommend Vacuum generator [Type] VN-07-L VN-07-L- Whenever possible compression fittings with sealing rings in combination with polyurethane tubes should be used for the for the air supply. This is to ensure minimum leakage. For all cylinders with piston rod the mounting position is defined as horizontal, with the supply ports on the bottom of the sample, except for DGPL cylinder and slide units. For the latter the port orientation is determined by the product design. Cylinders without piston rod are tested in horizontal and vertical mounting positions. If possible, standard mounting-accessories should be used. To minimize turbulence, the mounting accessories should disturb the airflow as little as possible. Prior to every measurement the supply pressure must be checked. The pressure should be 6.0 +/- 0.3 bar. Acoustic/visual/tactile check under test conditions to see that test specimens are operating correctly and that there is not sticking, jamming, stopping short of end positions, jerky motion, bottoming-out of cushioning or leaks which can be felt or heard. As any leakage leads to high emission of particles, there should be no detectable leakage. If there is any leakage detected, the test should be aborted. As the amount of particles, emitted by a cylinder, is not constant throughout its service life, particle measurements have to be undertaken at different stages of the service life. Particle measurement should be carried out after 20,000 duty cycles have been completed 136 Cleanroom Product Range-subjected to change
15 Festo Cleanroom project Conditions at which Festo cleanroom components are tested Operating conditions for cleanroom tests - Valves Pneumatic digital switching valves as follows: Mechanically-actuated/ manually-operated digital switching valves Pneumatically-actuated digital switching valves Solenoid-actuated digital switching valves Each test is conducted with a number of two identical specimens. The supply air should be clean dry air. This clean dry air is filtered with micro-filter which eliminates % of particles bigger than 0.01 µm. The operating pressure for all samples is 6.0 +/- 0.3 bar or maximum pressure, for specimen, whose operating pressure is less than 6.0 bar. The ambient temperature should be 20 +/- 2 degree Celsius. The medium temperature should not exceed 30 degree Celsius. Table shows: A pulse/interval ratio of 1:1 should be used for all frequencies. The additional volumes should be connected to the outputs of the test specimens via pieces of tubing and appropriate fittings. Ensure that the tubing connect does not increase the size of the additional volume by more than 20%. Tube size of supply line with maximum length of 100 cm. Whenever possible compression or barbed fittings in combination with polyurethane tubes should be used for the for the air supply. This is to ensure minimum leakage. For those valves that barbed fittings are not available, push-in fittings are used in the test. Acoustic/visual/tactile check under test conditions to see that test specimens (and pilot valves) are operating correctly and that there is no failure to switch, sticking, incomplete venting of outputs or leaks which can be felt or heard. Any departures from normal operation should be documented. As any leakage leads to high emission of particles, there should be no detectable leakage. If there is any leakage detected, the test should be aborted. Operating conditions for cleanroom tests - Air preparation units Filter Filters Fine and micro filters Pressure regulators Manual on-off valve Solenoid actuated on-off valve Soft start valves The specifications of test specimens are as: Pressure range: 0 to 7 bar Degree of filtration: refer to filter type filter or micro-filter connected Filter type LF or LFMA/B with connector plates are used Pressure gauge connections Manual condensate drain The supply air should be clean dry air. This clean dry air is filtered with micro-filter which eliminates % of particles bigger than 0.01 mm. The compressed air regulator is connected with micro-filter to adjust the pressure. The working pressure during the test is 7 bar. The air preparation unites are measured under the following conditions: Primary pressure (input pressure) p1=7 bar The controlled pressure (output pressure) p2= 6 bar Pressure drop p=1 bar The ambient temperature should be 20 ± 2 C. The medium temperature should not exceed 30 C. A minimum flow rate of 125 l/min is necessary for correct operation. However, flow measurement devices such as flow sensors or flowmeters are need to ensure this minimum flow rate. The switch frequency for on-off valves are 2 Hz. The mounting position for is vertical ±5. The operating voltage for solenoid actuated on-off valve is set as 24 ± 10% V DC. For manual condensate drain, plastic tubing is connected to the barb fitting. This is to ensure minimum leakage. Prior to every measurement the supply pressure must bechecked. The pressure should be 7.0 ± 0.3 bar. Acoustic/visual/tactile check under test conditions to see that test specimens are operating correctly. As any leakage leads to high emission of particles, there should be no detectable leakage. If there is any leakage detected, the test should be aborted. Although, it should be avoided that any medium such as air or lubricant is leaking out of the pneumatic system, it cannot be entirely avoided if pneumatic actuators are applied. In order to minimize harmful contamination, the medium, mostly compressed air or nitrogen, should be dried and filtered accordance to ISO , Class 1. Valve port size Switching frequency [Hz] Additional volume [ml] Inner diameter of tube [mm] Compressed Air Quality Standard: ISO M M M / / / / / Class Dust Water Oil [um] [mg/m³] [DTP] [g/m³] [mg/m³] Cleanroom Product Range-subjected to change 137
16 Festo Cleanroom project Benefits of using Festo cleanroom components In all automation processes, pneumatics plays an important role. This is the same for cleanroom, pneumatics are used in cleanroom for the following reasons: Automation of production sequence with pneumatics Lower space requirements with pneumatics Lower levels of contamination with pneumatics Laminar flow virtually unimpaired by pneumatics Benefits Avoidance or reduction of particle emissions both with stationary components and in an operating sequences Minimization of disturbance factors affecting laminar flow Counter measures against possible environmental influences (e.g. acids, aggressive media) Difference in comparison with standard products The following list is the difference between the standard products and those used in cleanroom. Generally suitable for unlubricated operation Cleanroom compatible grease used when necessary Cleanroom compatible markings Ducted exhaust ports and connections for air breather ports Extraction by means of vacuum where necessary Basic principle of Festo cleanroom product range It is known that there isn t a standard or guideline for cleanroom product design available. In order to develop products for cleanroom application, we mainly base on the principle of avoiding cleanroom contamination by preventing particles generated from the components. This principle includes the following three aspects: Non-contaminant release very low leakage construction Non-contaminant generation special material, surface treatment and special lubrication specification Non-contaminant in production processes component cleaning and double bag packaging The above three aspects can be achieved for cleanroom compatibility by modifying our standard products to cleanroom products with some special features. The general principle is to design an additional vacuum suction port so that air leakage during operation can be sucked back and extracted by vacuum. Non contaminants releasing: Drives Air leakage from the piston rod is sucked back and extracted by vacuum via a additional vacuum suction port on the front cap or barrel (housing) Leak-free design principle Valves Exhaust air from both main valve and pilot valve are released via common exhaust ports Breather air from underside of piston is removed via exhaust ports Leak-free design principle Air preparation unit Regulator: vent air in the bonnet is sucked through a vacuum connection on an additional ring Air filter: drain is discharged from cleanroom via drain guide port Grippers Air leakage is extracted via vacuum suction port Vacuum and other components Exhaust air is ported to the outside of cleanroom Shock absorber: replacement of a new housing with a vacuum port Fittings & tubing: air leakage is minimized by using the barbed fittings Non contaminant generating Piston rod is made of corrosion resistant steel Non contaminant in production process Cleaning individual components by ultrasonic cleaning bath All components are cleaned and assembled in a cleanroom Functional test in a cleanroom Double-packed in plastic bags in a cleanroom Production sequence of Festo cleanroom product range Basically, the manufacturing of clean room pneumatics is not any different from the design of any other pneumatic component. It is just, that special care is taken, to avoid any kind of contamination caused by the product. Design office Firstly the design of a standard product is modified with a view to cleanroom compatibility. Assembly All products are assembled outside the cleanroom, according to the standard assembly procedures. In very special cases, cleanroom grease is applied instead of the standard lubricant. Testing Just as any standard product, cleanroom products are tested, concerning their functionality. There is no particle emission test conducted for every product. Cleaning Before packing all products are cleaned under cleanroom condition of ISO Class 7. The cleaning is done either by means of an ultrasonic bath or with isopropanol wipers. Packaging Packaging is done in antistatic plastic bags. Whereby each product is double packed and sealed. Just as the cleaning, the packaging takes place under cleanroom condition of ISO Class 7. When the product is ready for shipment, it is transferred out of the cleanroom through an airlock. 138 Cleanroom Product Range-subjected to change
Unit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 2 HYDRAULIC AND PNEUMATIC CYLINDERS The material needed for outcome 2 is very extensive
Extract of the White paper Reduce energy costs in compressed air systems by up to 60%
Extract of the White paper Reduce energy costs in compressed air systems by up to 60% How can potential energy savings be identified? There are various measures for realising potential savings in compressed
Laminar Flow Cabinets and Workstations
VERTICAL AND HORIZONTAL HEPA FILTERED SYSTEMS FOR PROCESS OR OPERATOR PROTECTION Laminar Flow Cabinets and Workstations For procedures requiring protection from particulate contamination and for aseptic
Particle Monitoring Requirements in Pharmaceutical Cleanrooms
Particle Monitoring Requirements in Pharmaceutical Cleanrooms All drugs must be manufactured in accordance with the current Good Manufacturing Practice (cgmp) regulations. Pharmaceutical manufacturers
Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors
20000 Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors 23000 22000 21000 20000 09000 08000 07000 06000 05000 04000 03000 02000 01000 823 Notes 824 Technical
Environmental Monitoring of Clean Rooms
Environmental Monitoring of Raul Duarte President DDK Scientific, Corp. Copyright DDK Scientific, Corp. 2008, 2009, DDK Scientific, Corp. Proprietary A manufacturing facility for pharmaceutical products
Rotary actuators Rotary wing drives Series RAK. Brochure
Brochure 2 Rotary wing drives, angle of rotation: 30-270 Rotary wing drive, double-acting axis geometry: single 4 Rotary wing drives, angle of rotation: 90-270 Rotary wing drive, double-acting axis geometry:
CLEAN ROOM MONITORING REGULATORY STANDARDS
CLEAN ROOM MONITORING REGULATORY STANDARDS Air Classification as per Schedule M Maximum permitted number of particles / m3 equal or above at rest in operation 0.5µm 5.0µm 0.5µm 5.0µm A 3,520 29 3,500 29
MANTA Piston Distributor for Oil and Fluid Grease
MANTA Piston Distributor for Oil and Fluid Grease Function Piston distributors meter out and distribute the oil delivered by an intermittently actuated pump. The quantities of oil for the individual lube
Guide to in situ leak testing of HEPA filter configurations that cannot be conventionally scan tested
DOP Solutions Technical Document: Guide to in situ leak testing of HEPA filter configurations that cannot be conventionally scan tested Issue 1: Prepared by Neil Stephenson and Tim Triggs and edited by
ENVIRONMENTAL MONITORING / TESTING TO CONFORM WITH ISO14644 & TGA GMP REQUIREMENTS
ENVIRONMENTAL MONITORING / TESTING TO CONFORM WITH ISO14644 & TGA GMP REQUIREMENTS PRESENTATION TO RACI 20 TH APRIL 2016 PAUL MORGAN DIRECTOR CRITICAL CERTIFICATION PTY LTD CHANGES TO ISO14644 PART 1 CHANGES
APPLIED PNEUMATICS AND HYDRAULICS H TUTORIAL HYDRAULIC AND PNEUMATIC CYLINDERS. This work covers part of outcome 2 of the standard Edexcel module.
APPLIED PNEUMATICS AND HYDRAULICS H TUTORIAL HYDRAULIC AND PNEUMATIC CYLINDERS This work covers part of outcome 2 of the standard Edexcel module. The material needed for outcome 2 is very extensive so
Steering unit. Table of contents. Features RE 11872/05.06. Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min
Steering unit RE 11872/05.06 /10 Type LAGL Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min H7375 Table of contents Contents Page Features 1 Ordering code 2 Function, section 3 Device
SPECIAL APPLICATIONS
Page 1 SPECIAL APPLICATIONS The protection of microelectronics clean rooms using aspirating smoke detection systems requires special consideration. The physical configuration of the room(s) and the direction
CLASSIFICATION OF CLEANROOMS
CLASSIFICATION OF CLEANROOMS Cleanrooms are classified by the cleanliness of their air. The method most easily understood and most universally applied is the one suggested in the earlier versions (A to
Manual piston sampler...m 11
SAMPLING Manual piston sampler...m 11 Screw sampler...prec 22...PREC 100 Slide sampler...pr 55 Rotative screw sampler...prv Piston sampler...p 11 Sampler on belt conveyor...pba Rotating cup sampler...pgr
GMP ANNEX 1 REVISION 2008, INTERPRETATION OF MOST IMPORTANT CHANGES FOR THE MANUFACTURE OF STERILE MEDICINAL PRODUCTS
PHARMACEUTICAL INSPECTION CONVENTION PHARMACEUTICAL INSPECTION CO-OPERATION SCHEME PI 032-2 8 January 2010 RECOMMENDATION GMP ANNEX 1 REVISION 2008, INTERPRETATION OF MOST IMPORTANT CHANGES FOR THE MANUFACTURE
International Standard ISO 14644
International Standard ISO 14644 Cleanrooms and associated controlled environments Praphon Angtrakool Food and Drug Administration 1 International Standard : ISO 14644 ISO 14644 consists of the following
GenStore Archive Cabinet
GenStore Archive Cabinet Setup and Maintenance Manual Version A April 2014 Two GenStore Archives shown mounted on optional table stand. 2 Contents Getting Started... 4 Using this Manual...4 Safety Precautions...4
Air and Water Balancing - Sound and Vibration Testing - Cleanroom Services - Building Commissioning Building Envelope Testing Thermal Imaging
NEUDORFER ENGINEERS, INC. provides our customer with unbiased, professional, performance testing of Cleanrooms. We are committed to providing you, our customer, with value-added expertise in an effort
Kompressoren. Adsorption Dryer AD
Kompressoren Adsorption Dryer AD Adsorption Drying: why? Modern industries require compressed air that is increasingly filtered with low dew point and condensate. Today, the equipment is more sophisticated
Spetec Laminar Flow Systems. Operating Instructions
Spetec Laminar Flow Systems Operating Instructions 1 Spetec Laminar Flow Systems Operating Instructions Thank you for your trust in the Spetec clean room systems! Your chosen system is ideally suited for
LINEAR MOTION CONTROL
LINEAR MOTION CONTROL Technical Data Sheet Static Locks RLSS Series Nexen s new generation of linear holding/locking devices take rod locking technology to the next level. With superior performance, these
Laminar Flow Cabinets
Laminar Flow Cabinets The World s Most Practical Selection of Benchtop Laminar Flow Cabinets. 24 36 48 Simple, Effective Protection for Samples and Work Processes, Uncompromised Performance, Economical
LAMINAR FLOW CABINETS
LAMINAR FLOW CABINETS Vertical Laminar Flow Cabinets VLF 550 VLF650 VLF1000 VLF1200 VLF 1500 VLF1800 Monmouth Scientific's brand new range of Vertical laminar Flow (VLF) cabinets is available in six different
EU GMP Annex 1 Update 2008: Airborne Particle Counting
EU GMP Annex 1 Update 2008: Airborne Particle Counting Airborne Particle Counting for Pharmaceutical Facilities: Update 2008, EU GMP Annex 1 Morgan Polen - VP of Applications Technology, Lighthouse Worldwide
Medical Air Systems: Scroll
GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing
RUBBER SLEEVE KNIFE GATE VALVE
RUBBER SLEEVE KNIFE GATE VALVE The model knife gate is a wafer valve designed for a wide range of industrial applications. The double-seated design provides bi-directional shut off. The design of the valve
Fume Extraction: Guide to Safely Managing Solder Fumes in the Workplace
Fume Extraction: Guide to Safely Managing Solder Fumes in the Workplace Our thanks to OK International for allowing us to reprint the following. Why do we need fume extraction? Today s Electronics workplace
Particle testing in cleanroom high-pressure gas lines to ISO 14644 made easy with the MET ONE 3400 gas calibrations
Particle testing in cleanroom high-pressure gas lines to ISO 14644 made easy with the MET ONE 3400 gas calibrations B e c k m a n C o u l t e r L i f e S c i e n c e s 2 5 0 S. K r a e m e r B o u l e
Proportional pressure regulators VPPE
Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/
SITEMA PowerStroke. Technical Information TI-P11. 1 Function. 2 Applications. Mould Closing Devices series FSK. Contents
English translation of German original Technical Information TI-P11 SITEMA PowerStroke Mould Closing Devices series FS drive system for powerful forces on a short stroke hydraulic actuation closing force
WIBObarrier OCS - Open Containment Systems WIBObarrier CCS - Closed Containment Systems
WIBOjekt and WIBObarrier Air Curtain Systems. The perfect protection for person, product and environment. Filling Weighing Sampling Research Safe handling with high potent products / API WIBObarrier OCS
Unit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive
Cleaning. By the end of this chapter, you will be able to: Introduction. Definitions. Chapter 9
Chapter 9 By the end of this chapter, you will be able to: l Define the terms cleaning, decontamination, disinfection l List the factors that affect disinfection l Describe the aims of a cleaning schedule
Basic Hydraulics and Pneumatics
Basic Hydraulics and Pneumatics Module 1: Introduction to Pneumatics PREPARED BY IAT Curriculum Unit March 2011 Institute of Applied Technology, 2011 ATM 1122 Basic Hydraulics and Pneumatics Module 1:
Single sub-base valve
solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet
Material test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
Membrane air dryers MS-LDM1, MS series
Membrane air dryers MS-LDM1, MS series Membrane air dryers MS-LDM1, MS series Product range overview MS series service units Type Size Pressure regulation range [bar] Grade of filtration [μm] Pneumatic
HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999
CONTAMINATION CONTROL in hydraulic systems in the hydraulic system is a very wide and complex matter; the following is just a short summary. Our Customer Service is at your disposal for any further information.
Cooking at the Speed of light!
Cooking at the Infrared Cooking & Colouring Infrabaker is a modular infrared continuous cooking system developed by Infrabaker International. The machine is designed to cook and/or put colour on a wide
Workshop Compressors CLASSIC Series
www.kaeser.com Workshop Compressors CLASSIC Series Displacement: 210 to 40 l/min Pressure: 10 bar What do you expect from your CLASSIC workshop compressor? Quality results can be achieved only by using
Pneumatics Basic Level Set of Overhead Transparencies TP 101
Pneumatics Basic Level Set of Overhead Transparencies TP 0 Festo Didactic 0900 en Order No.: 0900 Description: PNEUM.FOLIEN. Designation: D:OT-TP0-GB Edition: 0/000 Author: Frank Ebel Graphics: Doris Schwarzenberger
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
Installation, operation and maintenance manual TX 35A
Installation, operation and maintenance manual TX 35A Rev.10 may 2012 Page 1 of 18 1.0.0 Table of contents INSTALLATION, OPERATION AND MAINTENANCE MANUAL...1 1.0.0 TABLE OF CONTENTS...2 2.0.0 ILLUSTRATIONS...2
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
ISO/VDMA Actuators. Engineering GREAT Solutions
ISO/VDMA Actuators Engineering GREAT Solutions 02 ISO/VDMA Actuators Contents 03 Introduction 04 ISO/VDMA Actuators 06 The ISO/VDMA Range 08 Industrial Options 10 Cleanline Options 12 IVAC innovation to
Radial piston pumps type R and RG
Radial piston pumps type R and RG Operating pressure p max = 700 bar Delivery flow Q max = 91.2 lpm (at 1450 rpm) Geometric displacement V g max = 64.2 cm 3 /rev. 1. General Motor pumps and hydraulic power
Spetec. Clean room. technology. Laminar flow box Clean room workbench CleanBoy Clean room cell Service, certification
Spetec Clean room technology Laminar flow box Clean room workbench CleanBoy Clean room cell Service, certification 1 Product overview PBS, FMS, and FBS series device families feature a modular design,
OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT
OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT PA/PH/OMCL (12) 77 7R QUALIFICATION OF EQUIPMENT ANNEX 8: QUALIFICATION OF BALANCES Full document title and reference Document type Qualification
Glossary of Heating, Ventilation and Air Conditioning Terms
Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment
Piston Accumulators. SK Series. Accumulator Catalog. Piston Types. Description. Sealing Systems. End Cap. O-ring. Sealing System. Piston.
SK Series Piston Types TYPE 2 pplication: Low-friction design for higher piston speeds, slow movements without stick-slip effect and high number of actuations (millions). ctual cycles achieved will vary
81000 Series Aluminum Gate Valve Installation and Repair Manual
High Vacuum Valves Leader in Quality and Value 81000 Series Aluminum Gate Valve Installation and Repair Manual Dear Customer, Thank you for choosing HVA as your vacuum valve supplier. Your valve will give
FlowFAST V. Vertical Laminar Airflow Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.
Vertical Laminar Airflow Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE. Vertical Laminar Flow Cabinets BEYOND MINIMUM SAFETY REQUIREMENT Cabinets are ISO Class 3 vertical laminar flow cabinets which
S300 Series Dust Monitors
S301 DustGuard S303 Trend Monitor S304 Emission Monitor S305 Stack Monitor Intrinsically Safe (ATEX) Dust Monitors Split Architecture (Remote)Models Data Logging Software S300 Series Dust Monitors Dust
Volkswagen Jetta, Golf, GTI 1999, 2000 2.8 Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)
17 Engine-Lubrication (Page GR-17) Lubrication system components, removing and installing Oil filter housing, disassembling and assembling Oil pan, removing and installing Oil pressure and oil pressure
Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF
Kompressoren Compressed Air Filters PF/DF/MF/SF/AF ALUP Filter For Compressed Air Purity Compressed air quality is related directly to the operating conditions of your compressor. Most compressor intake
Environmental Monitoring
Chapter 10 Environmental Monitoring By the end of this chapter, you will be able to: l List the types of environmental testing l Name three types of checks that are carried out to ensure the isolator is
RMF TANDEM 900 OFF-LINE FILTER SYSTEMS
RMF TANDEM 900 OFF-LINE FILTER SYSTEMS RMF Tandem 900 Off-line filter Systems can be applied to every imaginable industrial application where hydraulic or lubrication systems are present. An integrated
Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC
Technical Concept Filter Fan Unit COMPACT Type COMPACT AC Type COMPACT EC Ultra Filter Fan Unit COMPACT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
Product catalogue, pipe and sewer cleaning systems
Product catalogue, pipe and sewer cleaning systems Nozzles Rotorjet trolley Hose reels Cleaning devices www.hammelmann.com Contents (Navigation via Bookmarks) Rotorjet trolley Rotary joints, spray pipes
MEMBRANE VACUUM MINI PUMPS
MEMBRANE VACUUM MINI PUMPS The mini pumps described in this page are membrane-type. They can be used both as vacuum pumps and compressors. In the latter version they can supply compressed air 100% oil-free
Surface Engineering Solutions Rebuild, Repair and Protect Industrial Equipment
Surface Engineering Solutions Rebuild, Repair and Protect Industrial Equipment Whatever You Rebuild, Repair and Protect...... Find the Right Solution! Henkel's Solutions for all Surface Engineering Needs
Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC
Technical Concept Filter Fan Unit SILENT Type SILENT AC Type SILENT EC Filter Fan Unit SILENT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean
[ means: Save time, money and space! MAXXMILL 500. Vertical milling center for 5-side machining
[ E[M]CONOMY] means: Save time, money and space! MAXXMILL 500 Vertical milling center for 5-side machining MAXXMILL 500 MAXXMILL 500 is the ideal vertical milling center for the for the 5-axis operation
Electro-pneumatic control valves
Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N
World-Class Oil Sampling It is Possible
www.lubecontrol.com.au World-Class Oil Sampling It is Possible Lube Control Pty Ltd Providing lubrication solutions! Unit 5/53 Norfolk Rd, Marion, SA 5043 t: (08) 8298 5563 f: (08) 8298 6253 e: [email protected]
How To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
DUST EMISSION MONITORING SYSTEM
Applications Measurement of dust concentration in dry or moist, steamsaturated and corrosive stack gases Monitoring of municipal and hazardous waste and sewage sludge incinerators Monitoring of power plants
Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate
1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration
SITEMA PowerStroke. Technical Information TI-P12. 1 Function. 2 Applications. Mould Closing Devices series FSKP. Contents
SITEMA PowerStroke FSP ocking, actuating and releasing by pneumatic pressure English translation of German original Technical Information TI-P1 SITEMA PowerStroke Mould Closing Devices series FSP drive
T-Series Precision Linear Actuators Installation and Service Manual DW110353GB-1018 - EDITION 5. www.thomsonlinear.com
T-Series Precision Linear Actuators Installation and Service Manual DW110353GB-1018 - EDITION 5 www.thomsonlinear.com Version History Edition Number Edition Date Reason for Revision 1 2004 First edition
Class II Type B2 Laminar Flow Biological Safety Cabinets at Ordering Criteria for the National Institutes of Health
Background Class II Type B2 Laminar Flow Biological Safety Cabinets at Ordering Criteria for the National Institutes of Health This document provides guidelines for the design and installation of Class
UNIT II Robots Drive Systems and End Effectors Part-A Questions
UNIT II Robots Drive Systems and End Effectors Part-A Questions 1. Define End effector. End effector is a device that is attached to the end of the wrist arm to perform specific task. 2. Give some examples
italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines
PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines On customer request it is possible to supply: Benches for PCB Oven for PCB Chemicals
Lecture 30: Cleanroom design and contamination control
Lecture 30: Cleanroom design and contamination control Contents 1 Introduction 1 2 Contaminant types 2 2.1 Particles.............................. 2 2.2 Metal ions............................. 4 2.3 Chemicals.............................
kymanual or Automatic - it s your Choice
. kymanual or Automatic - it s your Choice ky LKB Automatic or Manual Butterfly Valve Application LKB is a sanitary automatically or manually operated butterfly valve for use in stainless steel pipe systems.
MOLECULAR DRAG PUMPS MDP SERIES
MOLECULAR DRAG PUMPS MDP SERIES MOLECULAR DRAG PUMPS MDP SERIES If you need: to replace a rotary vane pump with a dry pump for an application at 10-3 a turbopump that can operate up to 10 a pump that can
Kompressoren. Oil Water Separators OWS
Kompressoren Oil Water Separators OWS Removal Of Contaminants in Compressed Air Condensate. Atmospheric air contains large amounts of water vapour and dust particles. These contaminants are mixed with
Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C
Water droplet removal Water Separator Water droplet separation rate: % Model Flow capacity l/min (ANR) Max. flow capacity at 0.7 MPa inlet pressure 300 750 1,500 AMG 2,0 AMG to AMG/ Large dust particle
Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm
Specifications Features Type REED HALL EFFECT NPN or PNP Applicable Series Configurations Construction Materials Body Mounting Bracket Cable Characteristics Operating Temperature Accuracy All Cylinders
3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,
Pneumatic Grippers Parallel and Angular Grippers. Catalog 1900-2/US
Pneumatic Grippers Parallel and Angular Grippers Catalog 19-2/US Catalog 19-2/US OContents GPR Series Rotary vane driven design GPR GPCR Series P5G-HPM(C) Series P5G-HP Series GPT Series P5G-AP Series
Operataing Manual. Single stage radial Fan. Model MKV/TKV
01.2011 Operataing Manual Single stage radial Fan Model MKV/TKV REITZ-SCHWEIZ VENTILATOR AG Zentweg 11 CH-3006 Bern Telefon +41 (0) 31 / 938 85-85 Telefax +41 (0) 31 / 938 85-86 Internet: www.reitz-schweiz.ch
6 Crankcase Ventilation
6 Crankcase Ventilation Introduction... 6-3 Crankcase Ventilation Manager (CVM)... 6-5 Introduction... 6-6 CVM280B..................................... 6-7 CVM280T... 6-10 CVM424B....................................
DIESEL FUEL CONDITIONING
COD FILTRATION DIESEL FUEL CONDITIONING REMOVE WATER & PARTICLES TO EXTEND FUEL INJECTOR LIFE & INCREASE COMBUSTION ENGINE FUEL EFFICIENCY Remove free water to saturation point with high single pass efficiency
Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO
Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO The sum of technology TriAB Air ends The BALMA screw compressors are fitted with the unique TriAB air ends that are designed and
Linear drives DGC Key features
Linear drives DGC Linear drives DGC Key features General information Compact fitting length relative to stroke Loads and devices can be directly mounted on the slide Three types of cushioning available:
Plastic Injection Molding
Training Objective After watching this video and reviewing the printed material, the student/trainee will understand the principles and physical operations of the plastic injection molding process. An
Refrigeration Compressed Air Dryer Buran Ultrapulse
Refrigeration Compressed Air Dryer Buran Ultrapulse There is more to compressed air than just compressing air Compressed air is an indispensable source of operating and processing power in all areas of
Element D Services Plumbing
Medical Vacuum and Gas PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses medical vacuum, waste anesthetic gas disposal, compressed air, oxygen, nitrous oxide, nitrogen and carbon dioxide systems.
Norbro Series 40R Pneumatic Actuator Double Acting or Spring Return
Pneumatic Actuator Double Acting or Spring Return Since the mid-sixties the Norbro name has been recognised as the leading quarter turn actuator for industry. As proof of this, Norbro pneumatic actuators
B Dinesh Prabhu, Asst. Professor, P E S College Engg., Mandya, KARNATAKA 1
Firing Order Every engine cylinder must fire once in every cycle. This requires that for a four-stroke fourcylinder engine the ignition system must fire for every 180 degrees of crank rotation. For a sixcylinder
Electro-Pneumatic Bus Door Control Mechanism
Electro-Pneumatic Bus Door Control Mechanism Application and Feature 1. Pneumatic Door Mechanism actuates the open/close movements of bus door through two double acting cylinders and two linkages with
Incubator with mechanical convection
BF series 400 Incubators and cooling incubators Incubator with mechanical convection The BINDER incubator of the BF series with mechanical convection is suitable for all gentle incubation applications,
Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner
Elegant ECM Ceiling Air Conditioner ELEGANT ECM air conditioners allow to heat and cool very economically small and medium areas, like shops, show rooms, workshops, supermarkets. The range is made up of
M A N U A L 13-10-05
Documentation The following information sheets illustrate the description below: 12-WW01-4G-E Sectional view of the lance with main dimensions 12-W101-6G-E Sectional view of the head of the lance with
Schematic Symbols Chart (Design Hydraulic and Pneumatic circits)
Page 1 of 6 (Home) Symbols / Visit us on: Fluid Power, Automation and Motion Control for all Industries About Us Products Services Catalogs Place an Order Training & Information Contact Us Employee Access
Valve systems Base plates, according to standard ISO 5599-1. Brochure
ISO 5599-1 Brochure 2 ISO 5599-1 Single subbase Single subbase, thread connections on the side standard: ISO 5599-1 Frame size: ISO 1 - ISO 4 compressed air connection output: G 1/4 - G 1 Reversed pressure
